Final Presentation 1


Design - requirements Sustainable and energy efficient university building 1.Work: 10 office; meeting+presentation room; storage 2.Home: 10 living units with bath, kitchen, bedroom and living room; 3.Communication: foyer; exhibition room; club lounge; multipurpose hall 4.Infrastructure: management; technology center; administration; Approx. 1200m² 

2


Location

Salzburg, Austria cold, continental climate

ďƒ˜

3


Design Concept KISS Passive House components 

- Insulation - Triple glazed windows - Airtightness - Compactness - Mechanical ventilation with heat recovery 

PV-system on the roof Bore hole heat exchanger Winter garden/Thermal mass Natural ventilation by night Green facade 

4


Location

Salzburg, Austria

4 5


Urban Design Location on the side Orientation Considering the height of surrounded buildings View to/from castle 

6


Ground floor

7


1st floor

8


2nd floor

9


roof

10


section

11


section

12


facades

13


Living units

14


Living units

15


Area and volume Ground floor: -574m² GFA -495m² NFA -1485m³ Volume 1st floor: - 430m² GFA - 342m² NFA - 890m³ Volume 2nd floor: - 430m² GFA - 342m² NFA - 890m³ Volume

TOTAL AREA: - 1430m² GFA - 1180m² NFA - 3265m³ Volume 16


Energy strategy PASSIVE STRATEGY Insulation Triple glazed windows/Doors Airtightness Compactness Mechanical heat recovery ventilation Passive solar use Internal heat gains Self shading facade Thermal mass Natural Ventilation by night ACTIVE STRATEGY Photovoltaic for electricity Bore hole heat exchanger Solar thermal collectors

17


Passive strategies Passive House components

- Insulation - Triple glazed windows - Airtightness - Compactness - Mechanical ventilation with heat recovery 

Passive Solar use Winter garden/Thermal mass Natural ventilation by night Green facade 

18


Construction elements Outside wall, u-value 0,127 W/m²K

19


Construction elements Inside wall wintergarden, u-value 0,127 W/m²K

ďƒ˜

20


Construction elements roof, u-value 0,142 W/m²K

21


Construction elements Slap floor, u-value 0,141 W/m²K

22


Airtightness

23


Winter garden

24


Winter garden

25


Winter garden

26


Winter garden

27


Winter garden

28


Natural ventilation by night

29


Green facade

2 types of green facade - GrĂźne Wand - Fassadengarten

30


Green facade

31


Active strategies PV-system for Mechanical Ventilation, heat pump and lights Bore hole heat exchanger Solar thermal collectors 

32


PV- system on the roof

-Approx. 3700 kWh for mechanical Ventilation(dark grey) = 12 PV-modules - approx. 6600 kWh for heat pump(medium grey) = 21 PV-modules - 33 free PV-modules for lighting/electricity(light grey) 33


Bore hole heat exchanger Bore hole heat exchanger with heat pump

- The heat pump provides 37°C hot water which can be used for heating purposes. 10addition - In the summer the cold water is used for offices area activation for cooling - 3 drillings deliver 15kW for heating

34


Energy balance

NORTH EAST SOUTH WEST HORIZONTAL

35


Energy balance

36


Energy balance

37


Energy balance

38


39