Numerical Modeling of Konar Dam
Mr Ankur Agarwal
3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Current Analysis Under DRIP
3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
CAD modeling
Geometry was created using 2D sections of all blocks
Cavities, Shafts, Galleries are modeled in 3D model
Foundation was modeled.
Geometry was created in Abaqus/CAE and in CATIA V6
Non Overflow section 9
Overflow section
3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Konar DAM Model
10
Total number of nodes: 3028358 Total number of elements: 2672744 2489221 linear hexahedral elements of type C3D8T 36326 linear wedge elements of type C3D6T 147197 quadratic tetrahedral elements of type C3D10
3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Mesh Details
u → linear εµ
ε 11
∂ ∂x
u
→ constant
∆θ → linear
ε
th
µ ∆θ − average over element
ε
th
→ constant
Linear displacement, linear temperature, coupled element
Dam Blocks are meshed with brick elements. The elements used for this analysis are 8 noded coupled temperature displacement C3D8T
With these elements both thermal and mechanical loads can be applied in the same analysis.
Both temperature and displacement are output of this analysis
Foundation is meshed with tetrahedral elements. The elements used for this analysis is 10 noded quadratic tetrahedron with only displacement degrees of freedom.
Only mechanical loads can be applied on these elements.
3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Material Properties (Base Model)
Concrete
Rock
Elastic Modulus: 2.1E5 Kg/cm2
Elastic Modulus: 1.2E5 Kg/cm2
Poissons ratio: 0.2
Poissons Ratio: 0.2
Density: 2400 Kg/m3
Density: 2500 Kg/m3
Thermal Conductivity: 2.33 W/(m-K)
Cohesion: 2.5Mpa
Specific Heat: 960 J/(Kg-K) Thermal expansion: 1E-5
12
Frictional Angle: 45ᵒ
3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Sensitivity Analysis
13
Thermal conductivity, Specific heat and coefficient of thermal expansion is taken from Dr Pant’s report and the same is confirmed with USBR Engineering monograph 34.
Heat coefficient for convection between concrete-air and concrete-water is taken from report- “Effects of Changing Surrounding Conditions on the Thermal Analysis of the Moste Concrete Dam “ by Pavel Žvanut, Goran Turk and Andrej Kryžanowski.
Sensitivity analysis was carried out by changing the value of Young’s modulus, poissons ratio, coefficient of thermal expansion in order to find the effect on stresses.
3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Analysis Models studied
14
Model No.
Model Name
Youngs Modulus
Poissons Ratio
Coefficient of thermal expansion
Remarks
2D1
2d_Block8_withfoundation_2.inp (Base Model)
2.1E5 kg/cm2
0.2
1E-5/ᵒC
With foundation, without uplift, With galleries
2D2
2d_Block8_withfoundation_2_YM3.inp
3.0E5 kg/cm2
0.2
1E-5/ᵒC
With foundation, without uplift, With galleries
2D4
2d_Block8_withfoundation_2_YM35.inp
3.5E5 Kg/cm2
0.2
1E-5/ᵒC
With foundation, without uplift, With galleries
2D5
2d_Block8_withfoundation_2_MU18.inp
2.1E5 kg/cm2
0.18
1E-5/ᵒC
With foundation, without uplift, With galleries
2D6
2d_Block8_withfoundation_2_MU22.inp
2.1E5 kg/cm2
0.22
1E-5/ᵒC
With foundation, without uplift, With galleries
2D7
2d_Block8_withfoundation_2_alpha08.inp
2.1E5 kg/cm2
0.2
0.8E-5/ᵒC
With foundation, without uplift, With galleries
2D8
2d_Block8_withfoundation_2_alpha12.inp
2.1E5 kg/cm2
0.2
1.2E-5/ᵒC
With foundation, without uplift, With galleries
2D9
2d_Block8_withfoundation_2_withcrack.inp
2D10
2d_Block8_withfoundation_2_nogalleries.inp
2.1E5 kg/cm2
0.2
1E-5/ᵒC
With foundation, without uplift, No Galleries
2D11
2d_Block8_withfoundation_2_withcohuplift.inp
2.1E5 kg/cm2
0.2
1E-5/ᵒC
With foundation, with uplift, With Galleries
2D12
2d_Block8_withfoundation_2_cohuplift_pant_ft.in p
To be done
3DS.COM Š Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
3D Analysis Models
3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Loads
Mechanical Loads Gravity Load Varying water level, Silt
load
Thermal Loads: Convection
Radiation to ambient Direct
air temperature on down stream face
Solar radiation on downstream face
Convection
to water on upstream face
Convection
to air above water level on upstream face
Thermal
16
to air on downstream face
Radiation to air above water surface on upstream face
•
Air and Reservoir temp 3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Reference: ZHU Bofang
17
• •
Air temperature data is supplied by DVC for a typical year June-may The cycle is repeated for three years Reservoir temperature is determined from ZHU Bofang eqns with time and depth of reservoir as shown
Interactions:
*Tie, name=CP-1-Block-12-1-Block-13-1, adjust=yes, type=SURFACE TO SURFACE CP-2-Block-13-1, CP-1-Block-12-1
3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Model: 3D analysis of Block 13
18
*Tie, name=CP-1-Block-13-1-Block-14-1, adjust=yes, type=SURFACE TO SURFACE CP-1-Block-14-1, CP-1-Block-13-1 *Tie, name=Constraint-3, adjust=no
Block -13
CP-2-foundation-1, CP-2-Block-12-1 *Tie, name=Constraint-4, adjust=no CP-6-foundation-1, CP-6-Block-13-1 *Tie, name=Constraint-5, adjust=no CP-11-foundation-1, CP-11-Block-14-1
In this analysis, tie constraints are used to define interaction between blocks and foundation. This restricts slipping and opening between blocks and foundation.
Step-1: Static Analysis 3DS.COM Š Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Gravity Load is applied in step-1= 9.81m/s2
19
In the first step, gravity load is applied on the blocks and foundation. The units are converted to units: Kg, inch, sec: 386.21inch/s2
Step-2: Coupled Temp-Displacement analysis 3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Mechanical Loads
20
• •
Gravity Load: 9.8ms-2
Upstream Hydrostatic Pressure
Upstream Silt Load in vertical and horizontal direction
Water level is varied using DLOAD subroutine for three years Silt load is assumed to be at constant level
Step-2: Coupled Temp-Displacement analysis 3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Thermal Loads
21
• •
Upstream convection to water below water level
Upstream convection to air above water level
Upstream radiation to air above water level
Downstream radiation to air
Downstream convection to air
Downstream solar radiation
Upstream air temperature is varied for three years Upstream water temperature is varied due to air temperature fluctuations using ZHU Bofang equations • Solar radiation is computed on a sloping surface using Radiation equations
Step-2: Coupled thermo-structural analysis 3DS.COM Š Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Horizontal and Vertical Silt Load is applied
22
In the second step, horizontal and vertical downward silt load is applied on dam blocks below 1584inch from the top of dam. Units are in Kg, inch, sec Horizontal silt load expression: (360 * 386.219 * ( 1584 + Z ) ) / (39.37 * 39.37 * 39.37), where z is measured negatively from the top of the dam downwards Vertical silt load expression: (925 * 386.219 * ( 1584 + Z ) ) / (39.37 * 39.37 * 39.37)
Step-2: Coupled thermo-structural analysis 3DS.COM Š Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Varying hydrostatic pressure
23
In the second step, varying hydrostatic pressure is applied. Water level is varied using subroutine DLOAD and hydrostatic pressure load is applied depending on the location vertically downwards from the reservoir surface. Units is Kg, inch, sec Density=0.016387162 Gravity=386.27 Pressure=density*gravity*(H-coords(3)), where H is water head and Coords(3) gives the location of load points.
Step-2: Coupled thermo-structural analysis 3DS.COM Š Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Convection on upstream face
24
Surface Film condition is defined on upstream face to define convection heat loss to water and air. Subroutine FILM is defined to monitor water level and heat loss to water below water surface and heat loss to air above water surface Heat coefficient water: 556 W/(m2-K) Heat coefficent air: 55.6 W/(m2-K) Water temperature and air temperature is varied as shown earlier.
Step-2: Coupled thermo-structural analysis 3DS.COM Š Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Convection to air on downstream face
25
Surface Film condition is defined on downstream face to define convection heat loss to air. Heat coefficent air: 55.6 W/(m2-K) Air temperature is varied as shown earlier.
Step-2: Coupled thermo-structural analysis 3DS.COM Š Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Thermal radiation heat loss to Air on downstream face
26
Surface radiation is defined on the downsteam face for the heat gained/loss to air Emissivity: 0.90 Air temperature is varied as shown earlier. Newtons law of cooling=
Step-2: Coupled thermo-structural analysis 3DS.COM Š Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Solar radiation heat flux
27
Solar radiation is varied on the downstream face which depends on day of the month and time in day. CBRI method is used to compute heat flux. Subroutine DFLUX is written to compute total flux on surface. n= no. of days t= time in day B=(360*(n-81)/365)*3.14/180 EOT=9.87*sin(2*B)-7.53*cos(B)-1.5*sin(B) TC=4*(85.77-82.5)+EOT LST=t+TC/60 th=15*(LST-12)+360 dec=Asin(sin(23.45*3.14/180)*sin(360*(n-81)*3.14/365/180))*180/3.14 clat=cos(23.9*3.14/180) slat=sin(23.9*3.14/180) ALT=Asin(slat*sin(dec*3.14/180)+clat*cos(dec*3.14/180)*cos(th*3.14/180))*180/3.14 Azi=180+(Acos((slat*cos(dec*3.14/180)*cos(th*3.14/180)clat*sin(dec*3.14/180))/cos(ALT*3.14/180)))*180/3.14 Zd=Acos(slat*sin(dec*3.14/180)+clat*cos(dec*3.14/180)*cos(th*3.14/180))*180/3.14 B1=Azi-165
3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Sun tracker
28
Jan’13
July’13
Apr’13
Oct’13
3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Results
3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Model-2D1: 2d_Block8_withfoundation_2.inp Upper Gallery: S22
30
3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Model-2D4: 2d_Block8_withfoundation_2_YM35.inp Upper Gallery: S22
31
3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Model-2D8: 2d_Block8_withfoundation_2_alpha12.inp Upper Gallery: S22
32
3DS.COM Š Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Model-2D10: 2d_Block8_withfoundation_2_nogalleries.inp Upper Gallery: S22
33
3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Summary
34
Models
Max Stress S22 in Upper Gallery
2d_Block8_withfoundation_2.inp
0.453Mpa
2d_Block8_withfoundation_2_YM35.inp
0.824Mpa
2d_Block8_withfoundation_2_YM3.inp
0.748Mpa
2d_Block8_withfoundation_2_alpha12.inp
0.512 Mpa
2d_Block8_withfoundation_2_alpha08.inp
0.285 Mpa
2d_Block8_withfoundation_2_MU22.inp
0.468 Mpa
2d_Block8_withfoundation_2_MU18.inp
2d_Block8_withfoundation_2_nogalleries.inp
0.31Mpa
2d_Block8_withfoundation_2_withcohuplift.inp
0.456MPa
Summary: Analysis Models studied 3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Model No.
35
Poiss ons Ratio
Coefficient of thermal expansion
Model Name
Youngs Modulus
2D1
2d_Block8_withfoundation_2.inp (Base Model)
2.1E5 kg/cm2
0.2
1E-5/ᵒC
With foundation, without uplift, With galleries
100%
2D2
2d_Block8_withfoundation_2_YM3.inp
3.0E5 kg/cm2
0.2
1E-5/ᵒC
With foundation, without uplift, With galleries
165%
2D4
2d_Block8_withfoundation_2_YM35.inp
3.5E5 Kg/cm2
0.2
1E-5/ᵒC
With foundation, without uplift, With galleries
180%
2D5
2d_Block8_withfoundation_2_MU18.inp
2.1E5 kg/cm2
0.18
1E-5/ᵒC
With foundation, without uplift, With galleries
2D6
2d_Block8_withfoundation_2_MU22.inp
2.1E5 kg/cm2
0.22
1E-5/ᵒC
With foundation, without uplift, With galleries
103%
2D7
2d_Block8_withfoundation_2_alpha08.inp
2.1E5 kg/cm2
0.2
0.8E-5/ᵒC
With foundation, without uplift, With galleries
62.9%
2D8
2d_Block8_withfoundation_2_alpha12.inp
2.1E5 kg/cm2
0.2
1.2E-5/ᵒC
With foundation, without uplift, With galleries
113%
2D9
2d_Block8_withfoundation_2_withcrack.inp
2.1E5 kg/cm2
0.2
1E-5/ᵒC
With foundation, without uplift, With galleries
2D10
2d_Block8_withfoundation_2_nogalleries.inp
2.1E5 kg/cm2
0.2
1E-5/ᵒC
With foundation, without uplift, No Galleries
2D11
2d_Block8_withfoundation_2_withcohuplift.inp
2.1E5 kg/cm2
0.2
1E-5/ᵒC
With foundation, with uplift, With Galleries
2D12
2d_Block8_withfoundation_2_cohuplift_pant_f t.inp
2.1E5 kg/cm2
0.2
1E-5/ᵒC
With foundation, with uplift, With Galleries, initial temp 20ᵒC, solar absorvity=1, cap on solar flux
Remarks
Max S22
68.4%
3DS.COM Š Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Results: With Galleries and Without Galleries Upper Gallery: S22
36
3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
Rehabilitation measures Considered.
37
Plugging of the inspection gallery in a phased manner starting from the central portion i.e. starting from Block 13, 14 and extending sideways .
This is based on the Stress redistribution without gallery, there is a considerable reduction of stresses from 180% to 68.4%
Stitching of cracks, using steel liner, complete plugging or combination of them.
Extensive mapping of the existing cracks using LIDAR, followed by grouting of all surface cracks
Instrumentation for closure monitoring of Dam behavior after plugging the gallery.
Periodical remapping of cracks using LIDAR to monitor effects/success of rehabilitation design
38
3DS.COM © Dassault Systèmes | Confidential Information | 4/8/16 | ref.: 3DS_Document_2015
39