FX2N-10PG
01.2.20 6:13 PM
Page 1
■ Dimensions 43 (1.69)
■ Performance 87 (3.43)
Performance
FX 2N+20GM POWER ERROR START DOG X0 X1 øA øB
PGO FP RP CLR
90 (3.54)
FX2N-10PG
POSITIONING CONTROLLERS
FX 2N+10GM
FX 2N+10PG FX 2N+1PG
FX2N-10PG
FX1N unit: mm (inch)
FX1S
74 (2.91)
Cost
■ Performance specifications Item
Specifications
Power supply
5V DC: Supplied from PLC +24V (for pulse output): 24V DC ±10%, 40mA or less Supply from external power supply or PLC service power supply +5V (for internal control): 5V DC, 80mA Power supply through expansion cable from PLC
Number of I/O points occupied
8 input or output points of PLC for each FX2N-10PG
Number of control axes
One axis (Max. 8 independent axes for one PLC)
Command speed
Operations are enabled at pulse speed of 1Hz to 1MHz Command unit can be selected among Hz, cm/min, 10 deg/min and inch/min.
Setting pulse
As pulse converted value, −2,147,483,648 to +2,147,483,647 Absolute position specification or relative travel specification can be selected. Command unit can be selected among pulse, um, mdeg and 10 –4 inch. Multiplication of 10 0, 10 1, 10 2, 10 3 can be set for position data.
Pulse output format
Forward (FP) and reverse (RP) pulse or pulse (FP) with direction (RP) can be selected. Line driver output
External I/O
Photocoupler insulation and LED operation indicator at all points. Control input 3 points (START/DOG) 24V DC, 7mA (PG0) 5–24V DC, 20mA or less Interrupt input 2 points (X0/X1) 24V DC, 7mA 2-phase pulse input 1 point (øA /øB) line drive input Output 3 points (FR/RP) line driver 20mA or less (CLR) 5–24V DC, 20mA or less
Communication with PLC
Data communication with FX2N-PLC is performed using FROM/TO instructions.
L-173-1-C5350-A HI-0102 (OKA)
New publication, effective Feb. 2001 Specifications subject to change without notice.
HIGH SPEED PULSE OUTPUT REALIZES HIGH SPEED AND ACCURATE POSITIONING