The
EWAD~C family
Non-inverter
All year round… Inverter A p p l i e d S y s t e m s C ATA LO G U E 2 0 12
… top efficiency, low sound levels and flexible solutions for a wide range of applications
Applied Systems
Catalogue ■
ALL SEASONS PERFECT C MFORT
Free cooling
The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.
DAIKIN AIRCONDITIONING CENTRAL EUROPE HandelsgmbH campus 21, Europaring F12/402, A – 2345 Brunn/Gebirge Tel.: +43 / 22 36 / 3 25 57-0, Fax: +43 / 22 36 / 3 25 57-900 e-mail: office@daikin.at, www.daikin-ce.com
Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chilling Packages (LCP), Air handling units (AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: www.euroventcertification.com or using: www.certiflash.com
Daikin products are distributed by:
ECPEN12_02_dace_AS • Copyright Daikin We reserve the right for printing errors and model changes.
Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.
2012
TABLE OF CONTENTS Table of contents
1
New products 2012
2
Seosonal efficiency
3
Environmental awareness
116
Daikin solutions to R-22 phase out 118
APPLIED SYSTEMS
NEW
NEW NEW
NEW
NEW
NEW NEW
NEW
CHILLERS Air cooled chillers (Cooling only) EWAQ-ACV3 EWAQ-ACW1 EUWAC-FBZW1 EUWA(N-P-B)-KBZW1 EWAQ-BAWN/BAWP EWAQ-DAYN EWAD-E- EWAD-D- EWAD-BZ EWAD-C- EWAD-CZ EWAD-CF
4 9 10 11 12 13 14 15 16 18 26 28 34 36
Air cooled chillers (Heat pump) EWYQ-ACV3 EWYQ-ACW1 EUWY(N-P-B)-KBZW1 EWYQ-BAWN/BAWP EWYQ-DAYN EWYD-BZ
38 38 39 40 41 42 43
Air cooled condensing units ERQ VRV-AHU ERAD-E-
45 46 48 50
Water cooled chillers EWWP-KBW1N EWWD-J- EWWD-G- EWWD-I- EWWD-H- EWWQ-B-
53 54 56 58 60 62 64
Water cooled centrifugal chillers EWWD-FZXS DWSC, DWDC
66 66 68
Condenserless chillers EWLP-KBW1N EWLD-J- EWLD-G- EWLD-I-
71 72 73 74 75 1
Accessories DICN (Daikin Integrated Chiller Network) EHMC, EKBT (Hydraulic Module, Buffer tank) Dry Coolers & Condensers Cooling Towers
76 76 77 78 78
Ventilation Fan coil units FWC-BT/BF FWF-BT/BF FWC-AT/AF FWF-CT FWB-JT/JF FWB-BT FWT-BT/BF FWL-DT/DF FWM-DT/DF FWD-AT/AF FWV-DT/DF
79 80 81 82 83 84 85 86 87 88 89 90 91
Air Coolers
92
Heat Reclaim Ventilation VAM-FA
93 93
Rooftops UATYQ-CY1 UATYP-AY1
94 94 95
Air handling units
96
Plug And Play VRV-Connection AHU
100
Options & Accessories
107
New products 2012 14/41 Small inverter chiller - EWA/YQ-BA* >> Air cooled chiller with inverter compressor and fan >> High efficiency with leader-of-class ESEER up to 4.75 >> Available both in cooling only and heat pump models >> Wide capacity range from 17 kW up to 75 kW (7 sizes) >> Supplied optionally with factory mounted (standard/high-ESP) pump >> R-410A scroll compressor (1 or 2 circuits)
34 Large air cooled inverter chiller - EWAD-CZ >> Highest partial load efficiency scores in its class (ESEER up to 5.8) >> Large operating range (ambient temperatures from -18°C up to +50°C) >> Multiple sound levels to meet accoustic requirements >> Highest cooling capacity in its class (up to 1,800 kW) >> Extensive option list including fan speed regulation, rapid restart and heat recovery option
36 Free cooling chiller - EWAD-CF >> Air cooled chiller with free cooling system >> High efficiency version, combinable with 3 sound levels >> 11 sizes from 600 kW up to 1,565 kW >> Greater energy savings and reduced CO2 emissions during cold season
62 New flooded Chiller range - EWWD-H>> 11 sizes between 370 and 1,215 kW >> Condenser leaving water up to 50°C as standard >> High temperature kit for condenser leaving water up to 65°C >> Extended with heat pump option
96 D-AHU Professional and D-AHU Easy >> Air flow rates from 500 m³/h up to 124,000 m³/h >> From standard sizes to customized solutions >> Premium Eurovent performances >> Infinitely variable sizes
2
SEASONAL EFFICIENCY With European legislation* pressing energy users to drastically cut energy consumption, improve energy efficiency of buildings and homes, and meet the Commission’s 20/20/20 targets, industry is looking at more appropriate ways to evaluate efficiency. Thus, the new Directive aims at reducing the environmental impact of products in the EU. NOMINAL EFFICIENCY UP FOR IMPROVEMENT Measuring environmental performance is not new to Europe. Such measurements are used to set minimum requirements for manufacturers and to provide consumers with information on air conditioner performance so they can make intelligent choices when purchasing. The measurement method currently in place is that of nominal efficiency, a method, however, with limitations that result in a significant gap between rated and actual performance.
Temperature distribution curve Occurrence
SEASONAL EFFICIENCY IN LINE WITH PART LOAD PERFORMANCE To correct this situation, a more complex measurement for seasonal efficiency is being developed. The major differences between seasonal and nominal calculation are:
35° Temperature
7° Current point for COP Current point for EER Heating Cooling
>> The use of several rating temperatures for cooling and heating instead of one nominal temperature, better reflecting actual performance over an entire season
Annual energy consumption
>> Integration of operation at partial capacity instead of full capacity better estimation of the real-life performance of a unit since the majority
NOMINAL
of systems operate at partial load most of the time
TOTAL
>> Adoption of the seasonal efficiency calculation method will result in a
ESEER - European Seasonal Energy Efficiency Ratio To get a reliable energy analysis of the product annual performances it has been introduced a European Seasonal Energy Efficiency Ratio fully recognized in Europe (ESEER). The European Seasonal Energy Efficiency Ratio is a weighed formula enabling to take into account the variation of EER with the load rate and the variation of air or water inlet condenser temperature. The calculation formula and graph for ESEER is listed below: ESEER = 3% EER100% Load + 33% EER75%Load + 41% EER50%Load + 23% EER25%Load Therefore the ESEER is realistic tool, much better than full load EER, to be used to compare average efficiency of two chillers.
*EPB (Energy Performance of Buildings) Directive 2002/91/EC
3
ESEER parameter Part. load rate 100 75 50 25
Air temperature (°C) 35 30 25 20
Water temperature (°C) Weighting coeffizients 30 3% 26 33% 22 41% 18 23%
Extra low
Reduced
Low
Standard
Sound version High ambient
Premium
High
Standard
Efficiency version Centrifugal
Scroll
Screw
Compressor Swing
Free cooling
Inverter
Refrigerant
Page
General chiller Portfolio Air cooled overview units
INVERTER
Air cooled chillers (Cooling only) EWAQ005-007ACV3
10
R-410A
EWAQ009-011ACV3
10
R-410A
EWAQ-ACW1
11
R-410A
EUWAC-FBZW1
12
EUWA*-KBZW1
R-407C
13
R-407C
EWAQ-BAWN/BAWP
14
R-410A
EWAQ-DAYN
15
R-410A
EWAD-E-
16
R-134a
EWAD-D-
18
R-134a
EWAD-BZ
26
R-134a
EWAD-C-
28
R-134a
EWAD-CZ
34
R-134a
EWAD-CF
36
R-134a
Air cooled chillers (Heat pump) EWYQ005-007ACV3
38
R-410A
EWYQ009-011ACV3
38
R-410A
EWYQ-ACW1
39
R-410A
EUWY*-KBZW1
40
R-407C
EWYQ-BAWN/BAWP
41
R-410A
EWYQ-DAYN
42
R-410A
EWYD-BZ
43
R-134a
50
R-134a
Air cooled condensing units ERAD-E-
4
Capacity classes (kW) 0
17.5
200
500
1,000
2,000
5.2~7.1
8.5~11.0
9.0~13.2
11.6~23.8
11.3~55.3
16.8~63.0
80~254
97.9~413
177~622
329~515
619~2,008
635~1,802
602~1,555
0
17.5
200
500
1,000
2,000
500
1,000
2,000
5.2~7.1 5.65~7.75 8.5~11.0 10.0~13.0 9~13.2 11~14 9.1~50.0 11.9~54.0 16.8~63 16.8~63 77~252 88.7~281 248~583 270~615 0
17.5
200
116~488
5
INVERTER
Water cooled chillers (Cooling only & Heating only)
R-134a
60
R-134a
62
R-134a
EWWP-KBW1N
54
R-407C
EWWD-J-
56
R-134a
EWWD-G-
58
EWWD-I-
EWWD-H-
Water cooled chillers (Cooling only) EWWQ-B-
64
R-410A
Water cooled centrifugal chillers EWWD-FZXS
66
R-134a
DWSC DWDC
68
R-134a
EWLP-KBW1N
72
R-407C
EWLD-J-
73
R-134a
EWLD-G-
74
R-134a
EWLD-I-
75
R-134a
Condenserless chillers
6
Extra low
Reduced
Low
Standard
Sound version High ambient
Premium
High
Standard
Efficiency version Centrifugal
Scroll
Screw
Compressor Swing
Free cooling
Inverter
Refrigerant
Page
Portfolio Water cooled and Condenserless units
Capacity classes (kW) 0
17.5
200
500
1,000
2,000 9,000
1,000
2,000 9,000
1,000
2,000 9,000
13.0~195 16.6~248 120~570 142~681 166~604 204~712 333~1,510 388.4~1,790 369~1,215 419~1,356 0
17.5
200
500
380~2,152
0
17.5
200
500
114~1,048
300~4,500 600~9,000 0
17.5
200
500
1,000
12.1~62.4
110~530
161~526
328~1,422
7
2,000 9,000
A ir cooled chiller 1
7
3
2
5
4
5
Expansion vessel
t
Chillers
Evaporator
Buffer Tank
To fan coil units
t
t 1 1. 2. 3. 4.
6
5 5. 6. 7. 8.
Temperature sensor Filter Shut-off valve Pump
8
9
11 9. 10. 11. 12.
Pressure port Flow switch Air purge Pressure gauge
10
Balancing valve Drain valve Charging valve Safety valve
H eat recovery chiller 1 Chillers
7
3
2
5
4
5
Expansion vessel
t Buffer Tank Evaporator
12
Heat recovery exchanger
10
13
t 1
1. 2. 3. 4.
t
5
Temperature sensor Filter Shut-off valve Pump
9 8
6
Water Tank
5. 6. 7. 8.
Pressure port Flow switch Air purge Pressure gauge
11 To sanitary use
9. 10. 11. 12.
8
Balancing valve Drain valve Charging valve Safety valve
13. Mixing valve
To fan coil units
Air cooled chillers are most frequently used in the chilled water market. Out of its wide range of chillers in cooling only or heat pump version, with or without integrated hydronic components, DAIKIN always offers you a chiller fitting your application needs.
Daikin has taken great care to match major chiller components and refrigerant combinations to a point where high efficiency ranges of technically advanced and closely optimised air and water cooled units are now widely available for use with R-410A, R-407C and R-134a refrigerants. swing
scroll
screw
Air cooled chillers (Cooling only)
NEW
NEW NEW
EWAQ-ACV3 EWAQ-ACW1 EUWAC-FBZW1 EUWA(N-P-B)-KBZW1 EWAQ-BAWN/BAWP EWAQ-DAYN EWAD-E- EWAD-D- EWAD-BZ EWAD-C- EWAD-CZ EWAD-CF
10 11 12 13 14 15 16 18 26 28 34 36
Air cooled chillers (Heat pump)
NEW
EWYQ-ACV3 EWYQ-ACW1 EUWY(N-P-B)-KBZW1 EWYQ-BAWN/BAWP EWYQ-DAYN EWYD-BZ
38 39 40 41 42 43
9
EWAQ-ACV3
Air cooled mini chiller inverter EWAQ005-011ACV3
Digital controller
›› ›› ›› ›› ›› ›› ›› ››
Inverter technology ensures: continuous match of requested load, excellent part load efficiency (ESEER up to 4.57), significant reduction of starting currents, precise temperature control (evaporator leaving water) Low operating sound level Easy ‘plug and play’ installation Daikin swing (sizes 005-006-007) or scroll compressor (sizes 009-010-011) Integrated hydronics Available options: evaporator heater type (OP10) and high ESP pump up to 90 kPa (OPHP) Single phase power supply and main switch included Wide operating range
Cooling only Capacity class Cooling capacity Power input EER ESEER Dimensions Weight Water heat exchanger
Nom. Cooling
Unit Unit Type Water volume Nominal water flow Air heat exchanger Type Nominal ESP unit Pump Hydraulic components Expansion vessel Fan Air flow rate Fan motor Speed
Nom.
HeightxWidthxDepth
kW kW
005 5.2 1.89 2.75 3.75
006 6.0 2.35 2.55 3.83 805x1,190x360 100
mm kg
007 7.1 2.95 2.41 3.87
009 8.5 2.74 3.11 4.57
010 9.5 3.19 2.98 4.52 1,435x1,418x382 180
011 11.0 3.82 2.88 4.46
Brazed plate Cooling
Cooling Volume Cooling Nom. Cooling Nom. Steps Sound power level Cooling Nom. Sound pressure Cooling Nom. level Night quiet mode Cooling Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Water inlet / outlet Piping connections Water drain Power supply Phase / Frequency / Voltage
l l/min
kPa l m³/min rpm dBA dBA dBA °CDB °CDB
14.9
17.2 Tube type 45.1 6 -
49.4
62 48
1.01 20.4
24.4
27.2
38.3
63 50
Hermetically sealed swing compressor 5~20 10~43 R-410A
kg
1.7
2.95 Electronic expansion valve 1
inch inch Hz / V
G 5/4" (female) -
1" MBSP Hose nipple 1/2" FBSP 1~ / 50 / 230
10
31.5
Hi-XSS 58.0 54.6 49.1 10 96 100 97 780 8 64 51 45 Hermetically sealed scroll compressor 5~22 10~46
EWAQ-ACW1
Air cooled mini chiller inverter EWAQ009-013ACW1
Digital controller
›› ›› ›› ›› ›› ›› ›› ››
Inverter technology ensures: continuous match of requested load, excellent part load efficiency (ESEER up to 4.68), significant reduction of starting currents, precise temperature control (evaporator leaving water) Low operating sound level Easy ‘plug and play’ installation Daikin scroll compressor Integrated hydronics Available options: evaporator heater type (OP10) and high ESP pump up to 90 kPa (OPHP) Three phase power supply and main switch included Wide operating range
Cooling only Capacity class Cooling capacity Power input EER ESEER Dimensions Weight Water heat exchanger
Nom. Cooling
Unit Unit Type Water volume Nominal water flow Air heat exchanger Type Nominal ESP unit Pump Hydraulic components Expansion vessel Fan motor Speed
Nom.
HeightxWidthxDepth
Cooling
Cooling Volume Cooling Nom. Steps Sound power level Cooling Nom. Sound pressure Cooling Nom. level Night quiet mode Cooling Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping connections Water inlet / outlet Power supply Phase / Frequency / Voltage
kW kW
009 9.0 2.96 3.04 4.68
011 11.0 3.82 2.88 4.63 1,435x1,418x382 180 Brazed plate 1.01 31.5 Hi-XSS 49.1 10 780 8
mm kg l l/min kPa l rpm
25.8 56.4
dBA dBA dBA
64 51 45
kg
inch Hz / V
11
37.8 40.9
66 52 46 Hermetically sealed scroll compressor 5~22 10~46 R-410A 2.95 Electronic expansion valve 1 G 5/4" (female) 3N~ / 50 / 400
°CDB °CDB
013 13.2 5.10 2.59 4.52
EUWAC-FBZW1
Air cooled chiller with centrifugal fan EUWAC8FBZW1
μC² SE
›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ››
For indoor installation Optimised for use with R-407C Daikin scroll compressor Standard phase sequence controller Maximum external static pressure (ESP): 150Pa Pressure gauges Standard operation range down to -10°C Regulating switch Water inlet or outlet temperature control Input contacts/available outputs Input: on/off, pump/flow switch Outputs: compressor operation, summary alarm, pump relay contact Compatible with hydraulic module µC² SE DDC controller
Cooling only Capacity class Cooling capacity Capacity steps Power input EER Dimensions Weight
Nom. Cooling
Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Minimum water volume in the system Water flow rate Nom. Nominal water Cooling Heat exchanger pressure drop Model Type Quantity Air heat exchanger Type Fan Air flow rate Nom. Sound power level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Control Circuits Quantity Refrigerant circuit Charge Piping Evaporator water inlet/outlet connections Evaporator water drain Power supply Phase / Frequency / Voltage
kW % kW mm kg kg l l/min kPa
m³/min dBA
5 11.6
8 18.4 100-0 7.66 2.40 1,290x1,180x630 224 228 Brazed plate 153 53
5.2 2.23 1,345x856x630 164 166 101 33
9.67 2.46 1,395x1,330x630 261 266 212 68
26
42
48
AC70-24
AC70-34 1 Cross fin coil/Hi-X tubes and PE coated waffle louvre fins 109.8 66 Hermetically sealed scroll compressor -10 (OPZL) ~ 21 -10 ~ 43 R-407C Thermostatic expansion valve 1 3.9 FBSP 1 Field installation 3N~ / 50 / 400
AC70-40
70.2 63
°CDB °CDB
kg inch
10 23.8
2.1
Hz / V
12
126 69
4.7
EUWA(N-P-B)-KBZW1
Air cooled chiller EUWA*16KBZW1
μC² SE
›› ›› ›› ›› ›› ›› ›› ›› ››
››
Optimised for use with R-407C Daikin scroll compressor Reduced installation time thanks to integrated pump and;or buffer tank Possibility for a 200l buffer tank Low operating sound level Easy maintenance Main switch Water flow switch 3 different design options available: - EUWAN chiller without integrated hydraulic module ; - EUWAP chiller with integrated hydraulic module (pump, expansion vessel, hydraulic components) ; - EUWAB chiller with integrated hydraulic module (buffer tank, pump, expansion vessel, hydraulic components) µC² SE DDC controller
Cooling only Capacity class Cooling capacity Capacity steps Power input EER Dimensions Weight Water heat exchanger
Air heat exchanger Hydraulic components Fan group Fan group 2 Sound power level Compressor Operation range Refrigerant
Refrigerant circuit Refrigerant circuit 2 Piping connections Power supply
N5
Nom. Cooling
Nom.
HeightxWidthxDepth Unit Unit Operation weight Type Water volume Nominal water flow Cooling Nominal water Cooling Heat exchanger pressure drop Type Expansion vessel Volume Air flow rate Cooling Nom. Air flow rate Cooling Nom. Cooling Nom. Type Water side Cooling Min.~Max. Air side Cooling Min.~Max. Type Control Circuits Quantity Charge Charge Water inlet / outlet Phase / Frequency / Voltage
kW % kW mm kg kg l l/min kPa
l m³/min m³/min dBA
P5 11.3
N10 P10 B10 N12 P12 B12 N16 P16 B16 N20 P20 B20 N24 P24 B24 22.5 26.5 34.6 46.6 55.3 0-100 0-50-100 4.48 7.27 8.64 11.50 14.70 17.90 23.80 2.53 2.46 2.60 2.30 2.35 2.60 2.32 1,230x1,290x734 1,450x1,290x734 1,321x2,580x734 1,541x2,580x734 150 168 180 215 229 241 245 259 271 248 262 274 430 448 460 490 508 520 496 514 526 152 171 239 218 232 300 248 262 330 251 265 335 436 457 525 496 518 545 503 524 592 Brazed plate 1.14 1.615 1.9 2.375 2.964 3.9 4.524 32 51 64 76 99 134 158
N8
24 12 160 (per 2 fans) 67
°CDB °CDB
kg kg inch Hz / V
B5
3.9
P8 19.7
B8
38 -
43
37
22
Cross fin coil/Hi-X tubes and PE coated waffle louvre fins 12 12 12 12 12 170 (per 2 fans) 170 (per 2 fans) 76 78 79 81 Hermetically sealed scroll compressor -10 (OPZL) ~ 25 -15 ~ 43 R-407C Thermostatic expansion valve 1 2 4.6 5.9 6.0 4.6 5.9 4.6 5.9 G 1"1/4 (male) 2" (male) 3N~ / 50 / 400
13
12
6.0 6.0
EWAQ-BAWN/BAWP
Air cooled inverter chiller EWAQ-BA*
BRC21A52
›› ›› ›› ›› ›› ›› ››
High efficiency chiller with leader-of-class ESEER (up to 4.75) Minimal starting currents and short payback times No buffertank required for standard applications Naked or with factory mounted (standard/high-ESP) pump Low sound thanks to inverter compressor / fans EWAQ-BAWN: Naked EWAQ-BAWP: With pump
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight
Nom. Method Minimum capacity Cooling Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Heating Nominal water pressure drop Cooling Total Air heat exchanger Type Fan Air flow rate Cooling Nom. Sound power level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping connections Water inlet / outlet Power supply Phase/Frequency/Voltage
kW % kW
016 16.8
5.57 3.01 4.75
mm kg kg
264 267
l l/min l/min kPa
48 48 20
m³/min dBA
021 21.0
025 25.2
7.25 2.90 4.65 1,684x1,371x774 317 320 1 60 60 30
171
185 78
°CDB °CDB kg
7.6
inch Hz/V
1-1/4
14
032 040 050 31.5 42.0 50.4 Inverter controlled 25 9.25 12.9 14.9 19.0 2.72 2.44 2.82 2.65 4.45 4.00 4.60 4.40 1,684x1,684x774 1,684x2,358x780 397 571 401 577 Brazed plate 2 3 72 90 120 144 72 90 120 144 42 30 42 Hi-XSS 233 370 80 81 Hermetically sealed scroll compressor -10~20 -15~43 R-410A 9.6 15.2 Electronic expansion valve 1 1-1/2 3N~/50/400
064 63.0
26.7 2.36 3.95 1,684x2,980x780 730 738 5 181 181 30 466.0 83
19.2
EWAQ-DAYN
Air cooled chiller, multiple scroll EWAQ130-150DAYN
PCASO
›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ››
Optimised for use with R-410A refrigerant Multiple compressors per circuit Reliable and efficient scroll with high EER values High part load efficiency (ESEER) Anti-corrosion treated aluminium coils Low operating sound level Easy 'plug and play' installation Fans protected against abnormal operation (4 - 8 fans depending on unit size) Safety valves in each circuit Electronic circuit breakers Electronic expansion valve True dual plate brazed plate heat exchanger All hydronics can be accessed easily from 3 sides (no surrounding cabinet) Separate switchbox for easy access Compressors and controls at unit side Increased reliability via 2 independent refrigerant circuits (EWAQ130-260DAYN) Double circuit heat exchanger (from >100 kW) Non hermetic filter/dryer Daikin Pcaso controller with user friendly and powerful LCD interface
Cooling only Capacity class Cooling capacity Capacity steps
Power input EER ESEER Dimensions Weight
Nom.
Cooling
kW %
Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Nominal water flow Cooling Nominal water Cooling Total pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping Water inlet / outlet connections Water drain Power supply Phase / Frequency / Voltage
kW
mm kg kg l/min kPa
m³/min rpm dBA
080 80
100 105
180 210 182 209 21/290-25-50-75-100 43/50/570-25-50-75-100 71/79-100 46.6 56.3 64.5 74.6 2.81 2.70 2.82 2.80 4.34 4.22 4.36 4.32 2,311x2,000x2,631 2,311x2,000x3,081 1,500 1,550 1,800 1,850 1,517 1,569 1,825 1,877 Brazed plate 377 436 522 599
0-50-100 26.4 36.2 3.03 2.90 4.12 4.00 2,311x2,000x2,566 1,350 1,400 1,365 1,415 229
301
59
58
150 152
52
49
52
53
Cross fin coil/Hi-Xss tubes and poly ethylene coated waffle fins 800 860 1,290 900 970 88 89 90 Scroll compressor -10 (OPZL) ~ 25 -15 ~ 43 R-410A 19 25 29 28 Electronic expansion valve 2 3" OD 1/2"G 3~ / 50 / 400
780 880 86
°CDB °CDB kg
130 131
33 1
inch inch Hz / V
15
240 260 236 254 22/2840/50/560-25-50-75-100 72/78-100 82.8 94.0 2.85 2.70 4.20 4.00 2,311x2,000x4,850 3,150 3,250 3,189 3,292 677
728
51
47 1,600 900 91
39
3"
EWAD-E-SS
Air cooled chiller, standard efficiency EWAD130,140,160E-
MicroTech III
›› ›› ›› ›› ›› ›› ›› ››
Wide capacity range: 10 sizes to cover a range from 101 to 413 kW (SS), 97.9 to 398kW (SL) One refrigerant circuit with steppless single screw compressor Compact design with brazed plate heat exchanger Large operation range (ambient temperature down to -18°C) Low operating sound level (SL) Water supply down to -15°C Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication
Standard efficiency Standard sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight Water heat exchanger
Air heat exchanger Fan Sound power level Sound pressure level Compressor Operation range Refrigerant
Piping connections Power supply
Nom. Method Minimum capacity Cooling Nom.
kW
HeightxWidthxDepth Unit Unit Operation weight Type Water volume Nominal water flow Cooling Nominal water Cooling Heat exchanger pressure drop Type Air flow rate Nom. Speed Cooling Nom. Cooling Nom. Type Water side Cooling Min.~Max. Air side Cooling Min.~Max. Type Charge Circuits Quantity Evaporator water inlet/outlet Phase / Frequency / Voltage
mm kg kg
% kW
l l/s kPa
l/s rpm dBA dBA
100 101
120 121
inch Hz / V
160 163
180 183
210 214
260 256
310 307
360 360
410 413
Stepless 25 38.7 2.61
46.9 2.57
2.93 2,273x1,292x2,165 1,684 1,699
53.4 60.3 2.58 2.70 2.75 2.93 2,273x1,292x3,065 1,861 1,881
12 4.83
15 5.76
17 6.58
24
25
10,922
10,575 91.5 73.5
°CDB °CDB kg
140 138
18
21
20 7.77 24
68.5 71.7 2.67 2.98 2.81 3.02 2,273x1,292x3,965 2,086 2,116 Brazed plate 24 30 8.74 10.22 22
86.7 2.95 3.18
111 133 2.77 2.71 3.05 3.23 2,223x2,236x3,070 2,919 2,963
146 2.84 3.34
25 12.22
30 14.65
44 19.74
21
High efficiency fin and tube type with integral subcooler 16,383 15,863 21,844 21,150 32,767 920 92.3 93.0 94.2 73.7 73.9 75.1 75.0 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 23 28 30 33 46 1 3 3~ / 50 / 400
16
36 17.21
48
45 31,725 94.5 75.3
95.2 76.0
56
60
EWAD-E-SL
Standard efficiency Low sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight
Nom. Method Minimum capacity Cooling Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water flow Cooling Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage
kW % kW
mm kg kg l l/s kPa
l/s rpm dBA dBA
100 97.9
120 116
inch Hz / V
160 157
180 177
210 209
250 249
300 296
350 345
400 398
Stepless 25 38.8 47.9 2.52 2.42 3.01 2.97 2,273x1,292x2,165 1,784 1,799
53.0 60.6 2.53 2.60 2.85 3.00 2,273x1,292x3,065 1,961 1,981
12 4.68
17 6.40
15 5.54 23
8,372
8,144 89.0 71.0
째CDB 째CDB kg
130 134
18
21
20 7.51
67.8 72.1 2.61 2.89 3.07 3.32 2,273x1,292x3,965 2,186 2,216 Brazed plate 24 30 8.47 9.97 21
20
84.5 2.95 3.55
110 134 2.69 2.58 3.41 3.34 2,223x2,236x3,070 3,029 3,073
150 2.65 3.45
25 11.90
30 14.15
36 16.50
44 19.01
46
45
44
42
High efficiency fin and tube type with integral subcooler 12,558 12,217 16,744 16,289 25,117 715 89.8 90.5 91.7 71.2 71.4 72.6 72.5 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 23 28 30 33 46 1 3 3~ / 50 / 400
17
24,433 92.0 72.8
92.7 73.5
56
60
EWAD-D-SS
Air cooled chiller, standard efficiency EWAD390D-
MicroTech III
›› ›› ›› ›› ›› ›› ›› ››
Standard efficiency level Standard sound level configuration: condenser fan rotating at 920 rpm, rubber antivibration under compressor (SS) Low sound level configuration: condenser fan rotating at 715/900 rpm, rubber antivibration under compressor, compressor sound enclosure (SL) Stepless single-screw compressor Optimised for use with R-134a Large operation range (ambient temperature down to -18°C) Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication
Standard efficiency Standard sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight
Nom. Method Minimum capacity Cooling Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Circuits Quantity Refrigerant circuit Charge Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage
kW % kW
mm kg kg l l/s kPa
l/s rpm dBA dBA
390 389
440 436
470 466
152 2.56 3.36 2,223x2,234x3,139 2,960 3,090
164 2.66 3.54
167 2.79 3.55
4,030 4,195
4,220
530 532
560 556
580 578
194 2.74
205 2.72 3.56
197 2.93 3.39
3.52 2,223x2,234x4,040 4,230 4,395 Single pass shell & tube 165
4,235
130
165
175
18.60
20.80
22.20
24.00
25.40
26.50
27.60
45.6
37.9
66.5
47.1
52.1
57.4
51.2
32,772 95.8
96.7
76.5
56
139.7
Hz / V
3~ / 50 / 400
18
42,300 98.7
78.5
Semi-hermetic single screw compressor -15~15 -18~48 R-134a 2 70 76 82
60
160
High efficiency fin and tube type with integral subcooler 43,694 43,455 43,694 920 96 96.7 98.2 77.0
°CDB °CDB
kg mm
510 502 Stepless 12.5 184 2.73
79.0
87
92
EWAD-D-SL
Standard efficiency Low sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight
Nom. Method Minimum capacity Cooling Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Circuits Quantity Refrigerant circuit Charge Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage
kW % kW
mm kg kg l l/s kPa
l/s rpm dBA dBA
180 184
200 198
81.4 79.7 2.26 2.48 3.00 3.12 2,355x2,234x2,239 2,475 2,470 2,500 Plate to plate 25 30
230 225
250 245
84.5 2.66 3.31
93.4 101 108 2.62 2.58 2.54 3.21 3.26 3.23 2,355x2,234x3,139 2,860 2,960
9.40
10.70
11.70
28.9
21.8
57.8
49.0
15,300
280 275
100
8.80
14,900
22,900 900
300 320 370 400 298 321 370 404 Stepless 12.5 119 123 133 169 2.50 2.60 2.78 2.39 3.20 3.24 3.41 3.65 2,223x2,234x3,139 2,960 4,029 3,090 4,194 Single pass shell & tube 130 165
42
48
50
170
195 2.73 3.77 4,234
165
160
17.70
19.30
21.00
22.80
24.10
25.40
53.9
58.9
59.5
55.2
67.4
47.5
62.1
54.0
48.4
43.4
High efficiency fin and tube type with integral subcooler 22,600 22,300 24,428 94.7
33,489
32,572
97.2
715 94.2
95.7
96.2
77.5
74.5
76.0
76.5
84
86
Semi-hermetic single screw compressor -15~15 -18~48 R-134a 2 54 58 66 70
76 139.7
3~ / 50 / 400
19
170 186 203 2.59 2.57 2.49 3.67 3.57 3.67 2,223x2,234x4,040 4,224 4,229 4,394
530 533
15.30
114.3
Hz/V
510 505
14.20
94.3
88.9
480 477
13.10
75.0
36
440 440
12.50
93.7
째CDB 째CDB
kg mm
260 261
82
EWAD-D-SR
Air cooled chiller, standard efficiency EWAD370D-
MicroTech III
›› ›› ›› ›› ›› ›› ›› ››
Standard efficiency level Reduced sound level configuration: condenser fan rotating at 680/715 rpm, rubber antivibration under compressor, compressor sound enclosure (SR) Extra low sound level configuration: condenser fan rotating at 500 rpm, rubber antivibration under compressor, compressor and evaporator sound enclosure (SX) Stepless single-screw compressor Optimised for use with R-134a Large operation range (ambient temperature down to -18°C) Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication
Standard efficiency Reduced sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight
Nom. Method Minimum capacity Cooling Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage
kW % kW
mm kg kg l l/s kPa
l/s rpm dBA dBA
180 177
190 190
84.0 82.7 2.11 2.30 2.89 3.00 2,355x2,234x2,239 2,620 2,650 Plate to plate 25 30
220 219
240 238
85.2 2.57 3.34
94.7 103 111 2.51 2.44 2.38 3.21 3.23 3.16 2,355x2,234x3,139 2,890 3,100
9.10
10.40
11.30
26.9
20.1
55.1
46.6
15,300
mm
270 265
280 310 370 400 278 312 366 404 Stepless 12.5 122 125 138 169 2.28 2.49 2.65 2.39 3.13 3.25 3.42 3.65 2,223x2,234x3,139 3,110 4,040 3,240 4,342 Single pass shell & tube 130 165
100
8.50
14,900
22,900 680
12.00 50.8
12.60
13.30
55.2
89.3
42
48
50
88.9
530 533
170 186 203 2.59 2.57 2.49 3.67 3.57 3.67 2,223x2,234x4,040 4,240 4,542
195 2.73 3.77
165
160
19.30
21.00
22.80
24.10
25.40
52.7
65.1
47.5
62.1
54.0
48.4
43.4
89.7
170
33,489
32,572
92.2
715 90.7
92.2
92.7
72.5
71.0
72.5
73.0
84
86
Semi-hermetic single screw compressor -15~15 -18~48 R-134a 54 58 66 70 2
76 139.7
3~ / 50 / 400
20
510 505
17.40
114.3
Hz / V
480 477
14.90
70.0
36
440 440
High efficiency fin and tube type with integral subcooler 22,600 22,300 24,428
88.7
°CDB °CDB kg
250 252
82
EWAD-D-SX
Standard efficiency Extra low sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight
Nom. Method Minimum capacity Cooling Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Circuits Quantity Refrigerant circuit Charge Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage
kW % kW
mm kg kg l l/s kPa
l/s rpm dBA dBA
210 203
230 231
250 253
79.9 2.54 3.39 2,420x2,234x3,139 3,110 3,200
85.2 2.71 3.63
93.5 2.70 3.52 3,475
90
115
9.70
11.00
12.10
44.7
33.8
38
12,900
270 271
300 310 299 309 Stepless 12.5 104 114 126 136 2.59 2.50 2.37 2.27 3.55 3.44 3.39 3.25 2,420x2,234x4,040 3,425 3,430 3,590 Single pass shell & tube 165 160
370 370
410 413
148 2.49 3.24
169 2.44 3.49
3,560 3,735
4,302 4,472
84.3
173 187 2.60 2.63 3.61 3.58 2,420x2,234x4,940 4,506 4,581 4,676 4,746
175
170
165
14.30
14.70
17.70
19.70
21.50
23.50
38.3
34.9
37.7
40.5
44.5
43.9
50
44.8
25,933
28,625
33,116
65.0 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 2 60
56 114.3
Hz / V
65
70 139.7
3~ / 50 / 400
21
490 492
13.70
High efficiency fin and tube type with integral subcooler 17,200 26,495 500 84.7
17,900
450 451
12.90
째CDB 째CDB
kg mm
290 286
85.7
86.2
65.5
66.0
76
82
EWAD-D-XS
Air cooled chiller, high efficiency EWAD370D-
MicroTech III
›› ›› ›› ›› ›› ›› ›› ››
High efficiency Standard sound level configuration: condenser fan rotating at 900/920 rpm, rubber antivibration under compressor (XS) Reduced sound level configuration: condenser fan rotating at 680/715 rpm, rubber antivibration under compressor, compressor sound enclosure (XR) Stepless single-screw compressor Optimised for use with R-134a Large operation range (ambient temperature down to -18°C) Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication
High efficiency Standard sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight
Nom. Method Minimum capacity Cooling Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Circuits Quantity Refrigerant circuit Charge Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage
kW % kW
mm kg kg l l/s kPa
l/s rpm dBA dBA
250 247
280 275
300 302
79.1 3.12 3.56 2,355x2,234x3,138 2,905 3,000
87.1 3.16 3.60
94.1 3.20 3.62
104 113 127 3.15 3.12 3.16 3.85 3.67 3.59 2,355x2,234x4,040 3,235 3,240 3,400 Single pass shell & tube 165 160 15.60 46.1
3,285
95
115
11.80
13.10
14.40
48.1
44.9
48.8
22,300
330 327
380 376 Stepless 12.5 120 3.14 3.58
400 401
470 469
520 524
150 3.12 3.84 2,223x2,234x4,040 3,510 3,780
166 3.15 4.00
16.70
17.90
19.10
22.40
30,600
96.8
25.00
27.40
29.70
50.8
57.6
63.5
47.4
62.9
56.2
37.9
77.5
58
66
76
Semi-hermetic single screw compressor -15~15 -18~48 R-134a 2 73 76
22
255
54,616 920 99.2
86
100 168.3
3~ / 50 / 400
620 622
181 194 3.18 3.20 4.01 3.88 2,223x2,234x4,940 4,670 4,685 4,940
79.0
114.3
Hz / V
580 575
270
High efficiency fin and tube type with integral subcooler 29,700 44,000 43,000 43,695 900 97.2 98.7
°CDB °CDB
kg mm
350 351
EWAD-D-XR
High efficiency Reduced sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight
Nom. Method Minimum capacity Cooling Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Circuits Quantity Refrigerant circuit Charge Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage
kW % kW
mm kg kg l l/s kPa
l/s rpm dBA dBA
240 243
270 272
300 296
320 322
80.6 3.01 3.63 2,355x2,234x3,138 3,005 3,100
87.0 3.12 3.70
95.1 3.11 3.69
106 115 127 3.05 2.99 3.10 3.82 3.71 3.82 2,355x2,234x4,040 3,335 3,340 3,500 Single pass shell & tube 165 160 15.40 44.7
3,385
95
115
11.60
13.00
14.10
46.7
44.0
47.5
370 370 Stepless 12.5 119 3.12 4.01
390 394
460 455
510 512
152 2.99 3.89 2,223x2,234x4,040 3,610 3,880
167
16.40
17.70
18.80
21.70
91.8
24.40
26.80
28.60
49.2
56.2
55.6
44.8
60.4
53.7
36.1
72.5
60
560 561
183 198 3.07 3.03 4.11 3.93 2,223x2,234x4,940 4,770 4,785 5,040 255
41,861
41,864 715 93.7
73.5 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 2 80
68 114.3
Hz/V
23
104 168.3
3~ / 50 / 400
600 600
270
High efficiency fin and tube type with integral subcooler 12,500 33,488 680 92.2 93.2
째CDB 째CDB
kg mm
350 345
EWAD-D-HS
Air cooled chiller, high ambient EWAD380D-HS
MicroTech III
›› ›› ›› ›› ›› ›› ››
High ambient Standard sound level configuration: condenser fan rotating at 900/920 rpm, rubber antivibration under compressor Stepless single-screw compressor Optimised for use with R-134a Large operation range (ambient temperature down to -18°C) Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications
High ambient Standard sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight
Nom. Method Minimum capacity Cooling Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Fan motor Speed Cooling Nom. Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Circuits Quantity Refrigerant circuit Charge Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage
kW % kW
mm kg kg l l/s kPa
l/s rpm dBA dBA
200 195
210 208
77.2 75.5 2.52 2.76 3.11 3.26 2,223x2,234x2,239 2,475 2,470 2,500 Plate to plate 25 30
230 234
260 256
83.0
270 274
91.0
97.7 104 2.80 2.78 3.34 3.21 3.30 3.28 2,223x2,234x3,339 2,865 2,870 2,960 2.81
95
310 306
340 380 420 336 381 415 Stepless 12.5 120 127 141 2.80 3.00 2.94 3.25 3.57 3.61 2,223x2,234x4,040 3,185 3,277 3,300 3,447 Single pass shell & tube 115
112 2.73 3.27
90
450 448
480 478
150 2.98
162 2.95
510 514
550 547
175 182 2.94 3.00 3.68 3.66 3.71 2,223x2,234x4,940 3,942 4,356 4,361 4,112 4,526 170
165
590 587
191 3.07 3.79 4,366
160
9.30
9.90
11.10
12.20
13.10
13.80
14.60
16.00
18.20
19.80
21.40
22.80
24.50
26.10
28.00
31.5
23.7
46.1
52.1
53.7
59.3
64.4
58.3
69.9
45.8
52.5
58.0
50.9
55.7
52.6
23,900 22,800
High efficiency fin and tube type with integral subcooler 35,000 34,100 47,900 43,694 42,300 900 96.3 96.7 98.7 96.7
35,900
95.7
77.0
79.0
°CDB °CDB
kg mm
290 289
36
42
44
55
88.9
Semi-hermetic single screw compressor -15~15 -18~48 R-134a 2 56 58 66 70 114.3
Hz / V
90
97.7
99.2
99.7
77.5
79.0
79.5
95
100 139.7
3~ / 50 / 400
24
77.0
54,616 920
25
EWAD-BZSS/SL
Air cooled inverter chiller EWAD330,360BZ
PCO2
›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ››
ESEER up to 4.70 (SS/SL) High seasonal efficiency (ESEER up to 5.01) (XS/XL/XR) All models are PED pressure vessel approved Inverter stepless single-screw compressor Optimised for use with R-134a Cooling range: 329-515kW 2 truly independent refrigerant circuits DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops The ability to vary the output power in direct relation to the cooling requirements of the system allows to achieve building comfort conditions much faster at start-up Standard electronic expansion valve Partial and total heat recovery option available Power factor over 0.95 Standard operation range down to -10°C
Standard efficiency Standard/low sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight (SS) Weight (SL) Water heat exchanger
Air heat exchanger Fan Sound power level (SS) Sound power level (SL) Sound pressure level (SS) Sound pressure level (SL) Compressor Operation range Refrigerant
Piping connections Power supply
Nom. Method Minimum capacity Cooling Nom.
kW
HeightxWidthxDepth Unit Unit Operation weight Unit Operation weight Type Water volume Nominal water flow Cooling Nominal water Cooling Heat exchanger pressure drop Type Air flow rate Nom. Speed Cooling Nom. Cooling Nom. Cooling Nom. Cooling Nom. Type Water side Cooling Min.~Max. Air side Cooling Min.~Max. Type Charge Circuits Quantity Evaporator water inlet/outlet Phase / Frequency / Voltage
mm kg kg kg kg
% kW
l l/s kPa
l/s rpm dBA dBA dBA dBA
330 329
360 358
120.0 136 2.74 2.63 4.59 4.60 2,355x2,234x4,381 4,190 4,440 4,340 4,590 271 15.72
17.10
264
60
61
420 423 Stepless 13.5 147 159 2.69 2.66 4.55 4.59 2,355x2,234x5,281 4,590 4,840 4,740 4,990 Single pass shell & tube 256 18.87 20.21 72
67
460 459
490 488
520 515
168 2.73 4.57
181 2.70 4.70 2,355x2,234x6,181 4,990 5,240 5,140 5,390
193 2.67 4.60
21.93
23.32
24.61
78
69
76
248
High efficiency fin and tube type with integral subcooler 40,833 700 103.2 97.3 83.0 77.0 Semi-hermetic single screw compressor -9.5~15 -10~45 R-134a 99 105 114 2 168.3 3~ / 50 / 400
32,667 102.8 96.9
°CDB °CDB kg
400 395
73
mm Hz / V
26
49,000 103.6 98.2 83.5 77.5
118
121
EWAD-BZXS/XL/XR
High efficiency Standard/low/reduced sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight (XS)
Nom. Method Minimum capacity Cooling Nom.
HeightxWidthxDepth Unit Unit Operation weight Weight (XL) Unit Operation weight Weight (XR) Unit Operation weight Water heat Type exchanger Water volume Nominal water flow Cooling Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level (XS) Cooling Nom. Sound pressure Cooling Nom. level (XS) Sound power level (XL) Cooling Nom. Sound pressure Cooling Nom. level (XL) Sound power level (XR) Cooling Nom. Sound pressure Cooling Nom. level (XR) Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage
kW % kW
mm kg kg kg kg kg kg l l/s kPa
330 329
360 358
118.0 135 2.79 2.65 4.79 4.82 2,355x2,234x4,381 4,190 4,440 4,340 4,590 4,390 4,640 271 15.72
17.10
264
60
61
l/s rpm dBA dBA
32,667
dBA dBA
96.9
dBA dBA
92.9
420 423 Stepless 13 145 157 2.72 2.69 4.78 4.84 2,355x2,234x5,281 4,590 4,840 4,740 4,990 4,790 5,040 Single pass shell & tube 256 18.87 20.21 72
67
460 459
490 488
520 515
165 2.78 4.81
178 2.74 5.01 2,355x2,234x6,181 4,990 5,240 5,140 5,390 5,190 5,440
190 2.71 4.84
21.93
23.32
24.61
78
69
76
248
High efficiency fin and tube type with integral subcooler 40,833 700 103.2
102.8
83.0
77.0
73.0
27
98.2
94.2 73.5
Semi-hermetic single screw compressor -9.5~15 -10~45 R-134a 99 105 114 2 168.3 3~ / 50 / 400
mm Hz / V
103.6
77.5 93.3
73
49,000
83.5 97.3
째CDB 째CDB kg
400 395
118
121
EWAD-C-SS/SL
Air cooled chiller, standard efficiency EWAD-C15C-
MicroTech III
›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ››
Wide capacity range: 15 sizes to cover a range from 647 to 1,922 kW (SS/SL), 16 sizes from 619 to 1,833 kW (SR) Stepless single-screw compressor Large operation range (ambient temperature down to -18°C and up to 46°C) Reduced sound version (SR) All models are PED pressure vessel approved Optimised for use with R-134a 2-3 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications
Standard efficiency Standard/low sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight (SS) Weight (SL) Water heat exchanger
Air heat exchanger Fan Sound power level (SS) Sound pressure level (SS) Sound power level (SL) Sound pressure level (SL) Compressor Operation range Refrigerant
Piping connections Power supply
Nom. Method Minimum capacity Cooling Nom.
Unit
HeightxWidthxDepth
Unit Operation weight Unit Operation weight Type Water volume Nominal water flow Cooling Nominal water pressure drop Cooling Heat exchanger Type Air flow rate Nom. Speed Cooling Nom. Cooling Nom. Cooling Nom. Cooling Nom. Type Water side Cooling Min.~Max. Air side Cooling Min.~Max. Type Charge Circuits Quantity Evaporator water inlet/outlet Phase/Frequency/Voltage
kW % kW
mm kg kg kg kg l l/s kPa l/s rpm dBA dBA dBA dBA °CDB °CDB kg mm Hz/V
650 647
740 744
830 832
910 912
970 967
C12 1,152
C13 H14 1,319 1,418 Stepless
C15 1,538
C16 1,622
C17 1,714
C18 1,802
C19 1,875
C20 1,922
7 402 441 474 551 580 618 665 682 714 2.86 2.99 2.79 2.8 2.77 2.71 2.75 2.69 3.84 4.08 4.07 3.9 3.87 3.78 3.79 3.81 3.77 2,540x2,285 2,540x2,285x8,885 2,540x2,285x11,085 2,540x2,285x11,985 2,540x2,285x6,185 x7,985 5,630 5,740 5,760 6,280 6,560 7,280 7,900 10,320 10,710 10,770 11,240 11,600 5,910 5,990 6,010 6,530 6,810 7,520 8,280 10,730 11,110 11,260 12,110 12,480 5,920 6,030 6,050 6,570 6,850 7,570 8,190 10,770 11,150 11,210 11,680 12,040 6,200 6,280 6,300 6,820 7,100 7,810 8,570 11,170 11,550 11,700 12,560 12,920 Single pass shell & tube 266 251 243 386 408 474 850 30.9 35.56 39.74 43.6 46.21 50.85 55.04 62.9 67.7 73.5 77.51 81.89 86.00 89.50 91.70 73 59 52 61 68 63 72 54 58 59 65 73 36 39 40 High efficiency fin and tube type with integral subcooler 53,444 64,133 74,822 85,510 96,199 106,888 117,577 128,266 920 99.5 100.0 100.9 101.1 101.5 101.7 101.9 103.0 103.2 103.3 103.5 103.7 79.0 79.5 80.4 80.6 80.7 81.1 81.2 81.5 81.9 96.0 96.1 97.5 97.1 97.6 98.1 98.2 99.1 99.5 99.9 101 75.5 75.6 76.5 76.6 76.8 76.9 77 77.2 77.3 77.4 77.9 78 Semi-hermetic single screw compressor -8~15 -18~46 R-134a 128 146 144 162 178 196 260 261 275 305 2 3 168.3 219.1 3~/50/400 221 2.93 3.95
262 2.84 3.87
299 2.78 3.89
318 2.87 3.84
28
12.5 351 2.76 3.8
C11 1,064
378 2.82 3.88 2,540x2,285 x7,085 7,010 7,250 7,300 7,540
EWAD-C-SR
Standard efficiency Reduced sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight
Nom. Method Minimum capacity Cooling Nom.
Unit
HeightxWidthxDepth
Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage
kW % kW
620 619
720 715
790 789
880 876
920 922
223 2.77 4.08
272 2.62 3.96
315 2.51 3.98
331 2.65 3.99
12.5 369 2.5 4
5,920 6,200
6,030 6,280
mm kg kg l l/s kPa
l/s rpm dBA dBA
2,540x2,285x6,185 6,050 6,300
6,750 6,820
266
251
mm
C11 1,112
C12 H14 1,270 1,321 Stepless
C13 1,367
C14 1,471
C15 1,556
C14 1,623
C17 1,714
C18 1,795
C19 1,833
7 395 417 457 495 517 576 603 647 702 718 757 2.59 2.67 2.78 2.67 2.64 2.55 2.58 2.51 2.44 2.50 2.42 3.96 4.12 4.00 3.9 3.87 3.9 3.83 3.79 3.82 3.77 2,540x2,285 2,540x2,285 2,540x2,285x8,885 2,540x2,285x10,185 2,540x2,285x11,085 2,540x2,285x11,985 x7,085 x7,985 6,850 7,300 7,570 8,190 10,750 10,770 11,150 11,210 11,680 12,040 7,100 7,540 7,810 8,570 11,170 11,550 11,700 12,560 12,920 Single pass shell & tube 243 386 421 408 474 850
29.57
34.15
37.71
41.83
44.05
48.75
53.11
60.67
63.11
65.32
70.28
74.32
77.57
81.80
85.60
87.50
67
55
47
57
62
58
68
50
54
44
54
60
66
33
36
37
41,006 91.5
92.0
71.0
71.5
High efficiency fin and tube type with integral subcooler 49,207 57,408 65,610 73,811 82,012 90,213 715 92.5 93.0 93.5 93.8 94 94.8 94.9 95.1 95.2 72
72.5
째CDB 째CDB kg
C10 1,020
128
144 2
72.6
72.7
72.9
Semi-hermetic single screw compressor -8 ~ 15 -18 ~ 46 R-134a 162 178 196 260 219.1 3~ / 50 / 400
29
73.1
261
98,417
95.5 73.4
95.9 73.7
275
74
305
3
168.3
Hz / V
73.0
90,216
273
EWAD-C-XS/XL
Air cooled chiller, high efficiency EWAD-C11-C13C-
MicroTech III
›› ›› ›› ›› ›› ›› ›› ›› ›› ››
Wide capacity range: 17 sizes to cover a range from 756 to 2,008 kW (XS/XL), from 736 to 1,959 kW (XR) Stepless single-screw compressor Large operation range (ambient temperature down to -18°C and up to 50°C) All models are PED pressure vessel approved Optimised for use with R-134a 2-3 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications
High efficiency Standard/low sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight (XS) Weight (XL) Water heat exchanger
Air heat exchanger Fan Fan motor Sound power level (XS) Sound pressure level (XS) Sound power level (XL) Sound pressure level (XL) Compressor Operation range Refrigerant
Piping connections Power supply
Nom. Method Minimum capacity Cooling Nom.
Unit
HeightxWidthxDepth
Unit Operation weight Unit Operation weight Type Water volume Nominal water flow Cooling Nominal water pressure drop Cooling Heat exchanger Type Air flow rate Nom. Speed Cooling Nom. Cooling Nom. Cooling Nom. Cooling Nom. Cooling Nom. Type Water side Cooling Min.~Max. Air side Cooling Min.~Max. Type Charge Circuits Quantity Evaporator water inlet/outlet Phase/Frequency/Voltage
kW % kW
760 756
830 830
890 889
kg kg kg kg
233 3.25 4.02 2,540x2,285 x6,185 5,990 6,240 6,280 6,520
253 278 3.28 3.2 4.11 4.02 2,540x2,285 x7,085 6,340 6,360 6,580 6,600 6,630 6,650 6,870 6,890
l l/s kPa
251 36.1 80
243 39.67 42.49 56 64
l/s rpm dBA dBA dBA dBA
64,133
74,822
100.2
100.5 79.7 97.4 76.5
mm
96.8 76.3
°CDB °CDB kg mm Hz/V
146
162 168.3
990 C10 C11 C12 C13 H14 H15 C16 C17 C18 C19 C20 C21 C22 1,001 1,074 1,196 1,280 1,349 1,415 1,525 1,596 1,685 1,768 1,858 1,901 1,953 2,008 Stepless 12.5 7 307 338 364 400 411 444 475 504 533 561 590 615 642 672 3.26 3.18 3.29 3.2 3.29 3.19 3.21 3.17 3.16 3.15 3.09 3.04 2.99 4.11 4.05 4.14 4.02 4.28 4.31 4.35 4.17 4.16 4.13 4.12 4.03 4.01 2,540x2,285 2,540x2,285 2,540x2,285 2,540x2,285 2,540x2,285x9,785 2,540x2,285x14,685 x7,985 x11,985 x12,885 x13,785 7,190 7,470 8,220 8,240 8,900 11,570 11,900 12,260 12,600 7,600 7,870 8,610 8,630 9,890 12,430 12,760 13,140 13,470 7,480 7,760 8,510 8,530 9,190 12,010 12,350 12,700 13,040 7,880 8,160 8,900 8,920 10,180 12,870 13,200 13,580 13,910 Single pass shell & tube 403 386 979 850 871 850 47.82 51.32 57.13 61.18 64.45 67.50 72.86 76.24 80.48 84.47 88.79 90.77 93.2 95.8 61 69 45 51 71 77 84 62 68 64 37 39 41 43 High efficiency fin and tube type with integral subcooler 128,266 138,954 149,643 160,332 85,510 106,888 920 101.4 101.9 102.4 102.5 103.2 103.5 103.7 103.9 80.2 80.7 80.3 80.4 80.9 80.8 81 98 98.2 98.8 98.9 99.6 100 100.2 100.4 76.9 77.1 76.7 76.8 77.3 77.4 77 77.5 Semi-hermetic single screw compressor -8~15 -18~50 R-134a 182 214 225 248 297 312 328 343 343 2 3 219.1 273 3~/50/400
30
EWAD-C-XR
High efficiency Reduced sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight Water heat exchanger
Air heat exchanger Fan Sound power level Sound pressure level Compressor Operation range Refrigerant
Piping connections Power supply
Nom. Method Minimum capacity Cooling Nom.
Unit
HeightxWidthxDepth
Unit Operation weight Type Water volume Nominal water flow Cooling Nominal water pressure drop Cooling Heat exchanger Type Air flow rate Nom. Speed Cooling Nom. Cooling Nom. Type Water side Cooling Min.~Max. Air side Cooling Min.~Max. Type Charge Circuits Quantity Evaporator water inlet/outlet Phase/Frequency/Voltage
kW % kW
mm kg kg l l/s kPa l/s rpm dBA dBA 째CDB 째CDB kg mm Hz/V
740 736
810 811
870 866
970 974
C10 1,041
C11 1,168
C12 1,247
C13 1,302
H14 1,367
H15 1,468
C16 1,550
C17 1,639
C18 1,722
C19 1,813
C20 1,854
C21 1,902
C22 1,959
12.5 7 254 281 309 343 365 404 415 454 491 513 541 567 595 624 658 692 3.2 3.08 3.15 3.03 3.2 3.08 3.14 3.01 2.99 3.03 3.04 2.97 2.89 2.83 4.36 4.23 4.34 4.24 4.38 4.25 4.33 4.38 4.43 4.26 4.2 4.21 4.2 4.1 4.08 2,540x2,285 2,540x2,285 2,540x2,285 2,540x2,285 2,540x2,285 2,540x2,285x9,785 2,540x2,285x14,685 x7,085 x7,985 x11,985 x12,885 x13,785 6,630 6,650 7,480 7,760 8,510 8,530 9,190 12,010 12,350 12,700 13,040 6,870 6,890 7,880 8,160 8,900 8,920 10,180 12,870 13,200 13,580 13,910 Single pass shell & tube 251 243 403 386 979 850 871 850 35.17 38.74 41.36 46.54 49.76 55.78 59.56 62.21 65.20 70.00 74.07 78.32 82.3 86.61 88.5 90.7 93.5 76 54 61 58 65 43 49 67 73 79 59 65 61 35 37 39 41 High efficiency fin and tube type with integral subcooler 123,021 49,207 57,408 65,610 82,012 82,014 98,414 106,616 114,817 123,018 715 92 92.3 93.5 93.7 94.3 94.5 94.4 94.6 95.3 95.6 95.7 95.9 96.2 96.6 71.5 72.3 72.5 72.2 72.3 72.5 72.9 73 73.3 73.7 Semi-hermetic single screw compressor -8~15 -18~50 R-134a 146 162 182 214 225 248 297 312 328 343 343 2 3 168.3 219.1 273 3~/50/400 235 3.14 4.29 2,540x2,285 x6,185 6,280 6,520
31
EWAD-C-PS/PL
Air cooled chiller, premium efficiency EWAD-C-
MicroTech III
›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ››
Premium efficiency version (PS/PL) Premium efficiency and reduced sound version (PR) Wide capacity range: 9 sizes to cover a range from 821 to 1,562 kW (PS/PL), from 809 to 1,521 kW (PR) Stepless single-screw compressor Large operation range (ambient temperature down to -18°C and up to 52°C) All models are PED pressure vessel approved Optimised for use with R-134a 2 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications
Premium efficiency Standard/low sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight (PS)
Nom. Method Minimum capacity Cooling Nom.
Unit
HeightxWidthxDepth
Unit Operation weight Weight (PL) Unit Operation weight Water heat Type exchanger Water volume Nominal water flow Cooling Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level (PS) Cooling Nom. Sound pressure Cooling Nom. level (PS) Sound power level (PL) Cooling Nom. Sound pressure Cooling Nom. level (PL) Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage
kW % kW
820 821
890 890
980 975
225 3.64 4.44
249 3.58 4.5
274
mm
l l/s kPa
7,530 8,130 7,820 8,420
4.41
7,660 8,700 7,950 8,990
599
301
3.56
2,540x2,285x8,885
kg kg kg kg
C11 1,074
39.22
42.53
1,043 46.6
57
65
30
C12 1,158 Stepless 12.5 330 3.51 4.39
C13 1,279
363 3.52 4.53 4.44 2,540x2,285 2,540x2,285x9,785 x11,085 8,290 8,550 9,390 9,330 9,590 10,380 8,580 8,840 10,380 9,620 9,880 10,670 Single pass shell & tube 1,027 995 51.3 55.31 61.12 61
69
60
C14 1,390
C15 1,474
C16 1,562
396 3.51 4.31
424 3.48 4.33
453 3.45 4.32
2,540x2,285x11,985 9,730 10,720 10,720 11,010
66.41
979 70.30
74.50
73
81
89
High efficiency fin and tube type with integral subcooler 106,888 117,577 128,266 920 101.8 102.3 102.6 102.9
l/s rpm dBA dBA
96,199
79.5
80
80.5
80.4
80.5
80.8
81.1
dBA dBA
98.4
98.8
99.9
99.3
99.6
99.9
100.2
77.2
77.5
77.8
101
76.9
77
°CDB °CDB kg mm Hz / V
204
202
204
219.1
32
77.1
Semi-hermetic single screw compressor -8 ~ 15 -18 ~ 52 R-134a 220 252 2 273 3~ / 50 / 400
128,266 103.2
254
103.5
EWAD-C-PR
Premium efficiency Reduced sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight
Nom. Method Minimum capacity Cooling Nom.
Unit
HeightxWidthxDepth
Unit Operation weight Water heat Type exchanger Water volume Nominal water flow Cooling Nominal water Cooling Heat exchanger pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage
kW % kW
810 809
880 875
960 956
C10 1,053
219 3.7 4.63
244 3.58 4.59
272 3.51 4.54
299 3.52 4.59
mm
2,540x2,285x8,885
kg kg l l/s kPa
7,820 8,420
7,950 8,990
38.65
599 41.81
1,043 45.69
56
63
29
l/s rpm dBA dBA
73,811 92.7 71.2
mm
204
C13 1,251
364 3.44 4.53 2,540x2,285 2,540x2,285x9,785 x11,085 8,580 8,840 10,380 9,620 9,880 10,670 Single pass shell & tube 1,027 995 50.3 54.11 59.76 59
66
58
C14 1,359
C15 1,439
C16 1,521
396 3.43 4.51
425 3.39 4.50
457 3.33 4.45
2,540x2,285x11,985 10,720 11,010
64.95
979 68.7
72.6
70
77
84
High efficiency fin and tube type with integral subcooler 82,012 90,213 98,414 715 93.4 93.8 94.1 94.4 71.7 72.0 Semi-hermetic single screw compressor -8 ~ 15 -18 ~ 52 R-134a 204 220 252 2
째CDB 째CDB kg
C11 1,132 Stepless 12.5 330 3.43 4.5
202 219.1
273
Hz / V
3~ / 50 / 400
33
98,417 94.7 72.3
254
95 72.6
EWAD-CZXS/XL
Air cooled inverter chiller, high efficiency EWAD-CZ
MicroTech III
›› ›› ›› ›› ›› ›› ›› ››
ESEER up to 5.76 (XS/XL), 5.79 (XR) Inverter stepless single-screw compressor High efficiency, standard and low sound levels Optimised for use with R-134a Wide operating range Extensive option list (partial and total heat recovery option available) Low starting current MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications
High efficiency Standard/low sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight (XS) Weight (XL) Water heat exchanger
Air heat exchanger Fan Fan motor Sound power level (XS) Sound pressure level (XS) Sound power level (XL) Sound pressure level (XL) Compressor Operation range Refrigerant Refrigerant circuit Piping connections Power supply
Nom. Method Minimum capacity Cooling Nom.
Unit
HeightxWidthxDepth
Unit Operation weight Unit Operation weight Type Water volume Nominal water flow Cooling Nominal water pressure drop Cooling Heat exchanger Type Air flow rate Nom. Speed Cooling Nom. Cooling Nom. Cooling Nom. Cooling Nom. Cooling Nom. Type Water side Cooling Min.~Max. Air side Cooling Min.~Max. Type Circuits Quantity Charge Evaporator water inlet/outlet Phase/Frequency/Voltage
kW % kW
mm kg kg kg kg l l/s kPa l/s rpm dBA dBA dBA dBA °CDB °CDB
kg mm Hz/V
670 672
740 738
830 832
900 902
C10 1,037
C11 1,095 20
C12 1,236 Stepless
C13 1,308
C14 1,450
C15 1,545
C16 1,622
C17 1,709
C18 1,802
13 400 442 488 531 558 611 3.09 2.96 2.97 2.91 2.90 2.95 4.93 4.74 5.02 5.17 5.03 5.76 4.85 2,540x2,285 2,540x2,285 2,540x2,285 2,540x2,285 2,540x2,285 2,540x2,285x6,725 2,540x2,285x7,625 2,540x2,285x8,525 x11,625 x12,525 x13,425 x14,325 x10,325 5,880 6,000 6,620 6,870 7,440 8,570 8,970 9,600 9,940 11,370 12,190 12,920 6,140 6,250 6,860 7,110 7,880 8,960 9,360 9,980 10,320 12,220 13,040 13,790 6,170 6,280 6,900 7,150 7,720 8,850 9,250 9,880 10,220 11,790 12,610 13,340 6,430 6,530 7,140 7,390 8,160 9,240 9,640 10,260 10,600 12,640 13,460 14,210 Single pass shell & tube 263 248 241 441 383 374 850 871 32.00 35.20 39.70 43.00 49.50 52.30 59.00 62.40 69.20 73.70 77.40 81.50 86.00 80 75 55 64 63 69 46 51 61 71 62 68 64 High efficiency fin and tube type with integral subcooler 54,188 65,025 75,863 86,700 108,376 119,213 130,051 129,454 140,143 151,129 900 102.1 102.2 102.5 102.9 103.5 104.1 105.8 106.0 106.2 81.0 81.1 81.2 82.8 82.9 98.6 99.2 99.5 99.9 100.5 101.1 102.8 103.0 103.2 77.5 78.0 78.1 78.2 79.8 79.9 Semi-hermetic single screw compressor -8~15 -18~50 R-134a 2 3 141 161 178 200 235 275 320 327 343 361 168.3 219.1 273 3~/50/400 245 2.74 5.07
235 3.14 5.13
266 3.13 5.20
305 2.96 5.22
34
339 3.06 5.24
375 2.92 5.03
EWAD-CZXR
High efficiency Reduced sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight Water heat exchanger
Air heat exchanger Fan Fan motor Sound power level Sound pressure level Compressor Operation range Refrigerant Refrigerant circuit Piping connections Power supply
Nom. Method Minimum capacity Cooling Nom.
Unit
HeightxWidthxDepth
Unit Operation weight Type Water volume Nominal water flow Cooling Nominal water pressure drop Cooling Heat exchanger Type Air flow rate Nom. Speed Cooling Nom. Cooling Nom. Cooling Nom. Type Water side Cooling Min.~Max. Air side Cooling Min.~Max. Type Circuits Quantity Charge Evaporator water inlet/outlet Phase/Frequency/Voltage
kW % kW
mm kg kg l l/s kPa l/s rpm dBA dBA 째CDB 째CDB
kg mm Hz/V
640 635
700 700
790 789
850 852
980 976
C10 1,031 20
C11 1,170 Stepless
C12 1,235
C13 1,332
C14 1,443
C15 1,545
C16 1,631
C17 1,712
13 408 455 524 589 580 610 631 2.86 2.71 2.55 2.45 2.66 2.67 2.71 5.76 5.41 5.05 5.45 5.60 5.51 5.33 5.19 2,540x2,285 2,540x2,285 2,540x2,285 2,540x2,285 2,540x2,285 2,540x2,285x6,725 2,540x2,285x7,625 2,540x2,285x8,525 x11,625 x12,525 x13,425 x14,325 x10,325 6,170 6,470 7,100 7,360 7,950 9,120 9,530 10,180 10,530 12,150 12,990 13,740 6,430 6,720 7,340 7,600 8,390 9,500 9,920 10,550 10,910 13,000 13,840 14,610 Single pass shell & tube 263 248 241 441 383 374 850 871 30.30 33.40 37.60 40.70 46.60 49.20 55.80 58.9 63.60 68.80 73.70 77.80 81.70 73 69 51 58 57 63 43 47 53 59 57 62 59 High efficiency fin and tube type with integral subcooler 41,536 49,843 58,151 66,458 83,072 99,687 107,994 116,301 700 94.6 95.2 95.5 95.9 96.5 97.1 98.8 99.0 99.2 73.5 74.0 74.1 74.2 75.8 75.9 Semi-hermetic single screw compressor -8~15 -18~50 R-134a 2 3 141 161 178 200 235 275 320 327 343 361 168.3 219.1 273 3~/50/400 260 2.44 5.52
242 2.89 5.71
271 2.91
314 2.71
35
347 2.81 5.79
388 2.65 5.49
EWAD-CFXS/XL
Air cooled free cooling chiller, high efficiency EWAD-CF
MicroTech III
›› ›› ›› ›› ›› ››
Free cooling chiller High efficiency, standard/low (XS/XL) & reduced (XR) sound levels Greater energy savings and reduced CO2 emissions during cold season Wide capacity range: 11 sizes between 602 and 1,476 kW (XR), 640 and 1,555 kW (XS/XL) Wide operating range MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications
High efficiency Standard/low sound
Cooling only Capacity class Cooling capacity
Nom.
kW
Mechanical capacity Air temperature for free cooling 100% Capacity control Method Minimum capacity Power input Cooling Nom.
kW °C % kW
EER ESEER Dimensions Weight (XS) Weight (XS) Water heat exchanger
Air heat exchanger Fan Sound power level (XS) Sound pressure level (XS) Sound power level (XL) Sound pressure level (XL) Compressor Operation range Refrigerant
Piping connections Power supply
Unit
HeightxWidthxDepth
Unit Operation weight Unit Operation weight Type Water volume Nominal water flow Cooling Nominal water Cooling Heat exchanger pressure drop Type Air flow rate Nom. Speed Cooling Nom. Cooling Nom. Cooling Nom. Cooling Nom. Type Water side Cooling Min.~Max. Air side Cooling Min.~Max. Type Charge Circuits Quantity Evaporator water inlet/outlet Phase/Frequency/Voltage
mm kg kg kg kg l l/s kPa
l/s rpm dBA dBA dBA dBA °CDB °CDB kg mm Hz/V
640 640 (1) / 295 (2) 345 (2) -0.8
770 772 (1) / 365 (2) 407 (2) -0.1
850 852 (1) / 413 (2) 439 (2) 1.2
900 902 (1) / 434 (2) 468 (2) 0.4
257 (1) / 272 (1) / 293 (1) / 324 (1) / 74.3 (2) 87.9 (2) 90.7 (2) 99.8 (2) 2.49 (1) / 2.84 (1) / 2.90 (1) / 2.78 (1) / 8.62 (2) 8.78 (2) 9.4 (2) 9.04 (2) 3.44 3.52 3.78 3.50 2,565x2,480 2,565x2,480 2,565x2,480x7,985 x6,185 x7,085 7,760 8,340 8,900 8,040 8,580 9,140 8,050 8,620 9,190 8,320 8,870 9,430
C10 C11 C12 C13 C14 C15 C16 1,027 (1) / 1,089 (1) / 1,269 (1) / 1,349 (1) / 1,435 (1) / 1,493 (1) / 1,555 (1) / 502 (2) 524 (2) 594 (2) 652 (2) 663 (2) 659 (2) 722 (2) 524 (2) 565 (2) 675 (2) 697 (2) 772 (2) 834 (2) 0.9 0.1 2.9 2.1 1.3 0.7 0.1 Stepless 12.5 360 (1) / 399 (1) / 397 (1) / 439 (1) / 454 (1) / 492 (1) / 530 (1) / 109 (2) 118 (2) 131 (2) 143 (2) 152 (2) 160 (2) 170 (2) 2.85 (1) / 2.73 (1) / 3.19 (1) / 3.08 (1) / 3.16 (1) / 3.04 (1) / 2.93 (1) / 9.43 (2) 9.19 (2) 9.67 (2) 9.45 (2) 9.42 (2) 9.33 (2) 9.16 (2) 3.74 3.54 3.88 3.78 4.01 3.95 3.85 2,565x2,480x8,885
2,565x2,480x10,685
10,160 10,420 11,900 10,560 10,820 12,290 10,450 10,710 12,190 10,850 11,110 12,580 Single pass shell & tube 266 251 243 403 386 27.8 33.5 37.0 39.2 44.6 47.3 55.1 58.6 105 / 172 101 / 198 111 / 245 124 / 272 110 / 259 85 / 128 (2) 90 / 178 (2) 98 / 232 (2) (2) (2) (2) (2) (2) High efficiency fin and tube type with integral subcooler 50,367 60,440 70,513 80,587 920 99.5 100.2 100.5 101.4 101.9 102.4 79.0 (1) 79.7 (1) 80.2 (1) 80.7 (1) 80.3 (1) 96.0 96.8 97.4 98.0 98.2 98.8 75.5 (1) 76.3 (1) 76.5 (1) 76.9 (1) 77.1 (1) 76.7 (1) Asymm single screw -8~15 -20~45 R-134a 128 146 162 182 214 2 168.3 219.1 3~/50/400
(1) Cooling: evaporator 16/10°C, ambient 35°C, unit at full load operation; standard: ISO 3744 (2) Data is calculated at ambient air temperature 5°C, inlet water temperature 16°C.
36
12,540 13,530 12,830 13,820
12,620 13,610 12,910 13,900
12,670 13,660 12,960 13,950
62.4 139 / 305 (2)
979 64.9 150 / 328 (2)
67.6 162 / 354 (2)
95,253 102.5 80.4 (1) 98.9 76.8 (1)
225
248 273
EWAD-CFXR
High efficiency Reduced sound
Cooling only Capacity class Cooling capacity
Nom.
kW
Mechanical capacity Air temperature for free cooling 100% Capacity control Method Minimum capacity Power input Cooling Nom.
kW °C % kW
EER ESEER Dimensions Weight
Unit
HeightxWidthxDepth
Unit Operation weight Water heat Type exchanger Water volume Nominal water flow Cooling Nominal water Cooling Heat pressure drop exchanger Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase/Frequency/Voltage
mm kg kg l l/s kPa l/s rpm dBA dBA °CDB °CDB kg mm Hz/V
600 602 (1) / 270 (2) 332 (2) -2.3
740 739 (1) / 334 (2) 405 (2) -1.9
820 821 (1) / 379 (2) 442 (2) -0.6
870 866 (1) / 409 (2) 457 (2) -1.5
980 981 (1) / 459 (2) 523 (2) -0.9
263 (1) / 278 (1) / 299 (1) / 334 (1) / 70.3 (2) 84.3 (2) 88.4 (2) 95.9 (2) 2.29 (1) / 2.66 (1) / 2.75 (1) / 2.59 (1) / 8.56 (2) 8.77 (2) 9.29 (2) 9.03 (2) 3.59 3.66 3.89 3.62 2,565x2,480 2,565x2,480 2,565x2,480x7,985 x6,185 x7,085 8,050 8,620 9,190 8,320 8,870 9,430
368 (1) / 106 (2) 2.67 (1) / 9.27 (2) 3.83
C10 C11 C12 C13 C14 C15 1,034 (1) / 1,229 (1) / 1,302 (1) / 1,374 (1) / 1,424 (1) / 1,476 (1) / 492 (2) 562 (2) 598 (2) 619 (2) 640 (2) 668 (2) 542 (2) 667 (2) 704 (2) 756 (2) 784 (2) 809 (2) -1.7 0.7 -0.2 -1.1 -1.6 -2.3 Stepless 12.5 412 (1) / 403 (1) / 450 (1) / 466 (1) / 511 (1) / 556 (1) / 112 (2) 127 (2) 141 (2) 146 (2) 154 (2) 161 (2) 2.51 (1) / 3.05 (1) / 2.90 (1) / 2.95 (1) / 2.79 (1) / 2.66 (1) / 9.21 (2) 9.67 (2) 9.22 (2) 9.4 (2) 9.26 (2) 9.15 (2) 3.63 4.13 3.89 4.09 4.02 3.92
2,565x2,480x8,885
2,565x2,480x10,685
10,450 10,710 12,190 12,830 10,850 11,110 12,580 13,820 Single pass shell & tube 266 251 243 403 386 26.2 32.1 35.7 37.6 42.6 44.9 53.4 56.6 59.7 / 225 113 / 248 92 / 219 (2) 103 / 243 128 / 282 76 / 115 (2) 97 / 159 (2) 84 / 167 (2) 93 / 184 (2) 102(2) (2) (2) (2) High efficiency fin and tube type with integral subcooler 38,934 46,721 54,508 62,294 73,010 715 91.5 92.0 92.3 93.5 93.7 94.3 94.5 71.0 (1) 71.5 (1) 72.3 (1) 72.5 (1) 72.2 (1) 72.3 (1) Asymm single screw -8~15 -20~45 R-134a 128 146 162 182 214 225 2 168.3 219.1 3~/50/400
(1) Cooling: evaporator 16/10°C, ambient 35°C, unit at full load operation; standard: ISO 3744 (2) Data is calculated at ambient air temperature 5°C, inlet water temperature 16°C.
37
12,910 13,900
12,960 13,950
979 61.9 137 / 301 (2)
64.1 146 / 321 (2)
94.6 72.5 (1)
248 273
EWYQ-ACV3
Air cooled heat pump mini chiller inverter EWYQ005-011ACV3
Digital controller
›› ›› ›› ›› ›› ›› ›› ››
Inverter technology ensures: continuous match of requested load, excellent part load efficiency (ESEER up to 4.57), significant reduction of starting currents ; precise temperature control (evaporator leaving water) Low operating sound level Easy ‘plug and play’ installation Daikin swing (sizes 005-006-007) or scroll compressor (sizes 009-010-011) Integrated hydronics Available options: evaporator heater type (OP10) and high ESP pump up to 90 kPa (OPHP) Single phase power supply and main switch included Wide operating range
Heating & Cooling Capacity class Cooling capacity Heating capacity Power input EER COP ESEER Dimensions Weight
Nom. Nom. Cooling Heating
Nom. Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Heating Air heat exchanger Type Nominal ESP unit Cooling Pump Hydraulic components Expansion vessel Volume Fan Air flow rate Cooling Nom. Heating Nom. Fan motor Speed Cooling Nom. Heating Nom. Steps Sound power level Cooling Nom. Heating Nom. Sound pressure Cooling Nom. level Heating Nom. Night quiet Cooling mode Heating Compressor Type Operation range Water side Cooling Min.~Max. Heating Min.~Max. Air side Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping Water inlet / outlet connections Water drain Power supply Phase / Frequency / Voltage
kW kW kW kW
005 5.2 5.65 1.89 1.97 2.75 2.87
006 6.0 6.35 2.35 2.24 2.55 2.83 805x1,190x360 100 104
mm kg kg
007 7.1 7.75 2.95 2.83 2.41 2.74
009 8.5 10.0 2.74 2.91 4.37 3.44 4.57
010 9.5 11.5 3.19 3.38 2.98 3.40 4.52 1,435x1,418x382 180 -
011 11.0 13.0 3.82 3.86 2.88 3.37 4.46
Brazed plate l l/min l/min kPa l m³/min m³/min rpm rpm dBA dBA dBA dBA dBA dBA °CDB °CDB °CDB °CDB
17.2 19.5 Tube type 45.1 6 -
14.9 17.5 49.4
62
1.01 27.2 33.0 Hi-XSS 58.0 54.6 10 96 100 90 780 760 8 64 64 51 51 45 42 Hermetically sealed scroll compressor 5~22 25~50 10~46 -15~35
20.4 23.5
24.4 28.7
38.3
63 -
48 48
50 49
Hermetically sealed swing compressor 5~20 25~50 10~43 -15~25 R-410A
kg
1.7
2.95 Electronic expansion valve 1 G 5/4" (female) -
1" MBSP Hose nipple 1/2" FBSP Hz / V
1~ / 50 / 230
38
31.5 37.3 49.1 97
EWYQ-ACW1
Air cooled heat pump mini chiller inverter EWYQ009ACW1
Digital controller
›› ›› ›› ›› ›› ›› ›› ››
Inverter technology ensures: continuous match of requested load, excellent part load efficiency (ESEER up to 4.68), significant reduction of starting currents, precise temperature control (evaporator leaving water) Low operating sound level Easy ‘plug and play’ installation Daikin scroll compressor Integrated hydronics Available options: evaporator heater type (OP10) and high ESP pump up to 90 kPa (OPHP) Three phase power supply and main switch included Wide operating range
Heating & Cooling Capacity class Cooling capacity Heating capacity Power input EER COP ESEER Dimensions Weight Water heat exchanger
Air heat exchanger Pump Hydraulic components Fan motor
Nom. Nom. Cooling Heating
Unit Unit Type Water volume Nominal water flow
Nom. Nom.
HeightxWidthxDepth
Cooling Heating
Type Nominal ESP unit Cooling Expansion vessel Volume Speed Cooling Nom. Heating Nom. Steps Sound power level Cooling Nom. Heating Nom. Sound pressure Cooling Nom. level Heating Nom. Night quiet Cooling mode Heating Compressor Type Operation range Water side Cooling Min.~Max. Heating Min.~Max. Air side Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping connections Water inlet / outlet Power supply Phase / Frequency / Voltage
kW kW kW kW
009 9.0 11.0 2.96 3.23 3.04 3.41 4.68
011 11.0 12.5 3.82 3.70 2.88 3.38 4.63 1,435x1,418x382 180 Brazed plate 1.01 31.5 35.8 Hi-XSS 49.1 10 780 760 8
mm kg l l/min l/min kPa l rpm rpm
25.8 31.5 56.4
dBA dBA dBA dBA dBA dBA
64
013 13.2 14.0 5.10 4.19 2.59 3.34 4.52
37.8 40.1 40.9
66 64
51
52 51
45 42
46 43 Hermetically sealed scroll compressor 5~22 25~50 10~46 -15~35 R-410A 2.95 Electronic expansion valve 1 G 5/4" (female) 3N~ / 50 / 400
°CDB °CDB °CDB °CDB kg
inch Hz / V
39
EUWY(N-P-B)-KBZW1
Air cooled heat pump chiller EUWY*16KBZW1
μC² SE
›› ›› ›› ›› ›› ›› ›› ›› ››
››
Optimised for use with R-407C Daikin scroll compressor Reduced installation time thanks to integrated pump and/or buffer tank Possibility for a 200l buffer tank Low operating sound level Easy maintenance Main switch Water flow switch 3 different design options available: - EUWYN chiller without integrated hydraulic module; - EUWYP chiller with integrated hydraulic module (pump, expansion vessel, hydraulic components); - EUWYB chiller with integrated hydraulic module (buffer tank, pump, expansion vessel, hydraulic components) µC² SE DDC controller
Heating & Cooling Capacity class Cooling capacity Heating capacity Capacity steps Power input EER COP Dimensions Weight Water heat exchanger
Air heat exchanger Hydraulic components Fan group Fan group 2 Sound power level Compressor Operation range
Refrigerant
Refrigerant circuit Refrigerant circuit 2 Piping connections Power supply
N5
Nom. Nom. Cooling Heating
Nom. Nom.
HeightxWidthxDepth Unit Unit Operation weight Type Water volume Nominal water Cooling flow Heating Nominal water Cooling Filter pressure drop Heating Filter Type Expansion vessel Volume Air flow rate Cooling Nom. Air flow rate Cooling Nom. Cooling Nom. Type Water side Cooling Min.~Max. Heating Min.~Max. Air side Cooling Min.~Max. Heating Min.~Max. Type Control Circuits Quantity Charge Charge Water inlet / outlet Phase / Frequency / Voltage
kW kW % kW kW
mm kg kg l l/min l/min kPa kPa l m³/min m³/min dBA °CDB °CDB °CDB °CDB
kg kg inch Hz / V
P5 9,1 9.1 11.9 11,9
B5
N8
P8 17,1 17.1 18.5 18,5
B8
N10 P10 B10 N12 P12 B12 N16 P16 B16 N20 P20 B20 N24 P24 B24 21.0 21,0 25.0 25,0 34.2 34,2 40 50.0 50,0 24.0 24,0 27.0 27,0 37.0 37,0 46 54.0 54,0 0-100 0-50-100 3.77 3,77 7.38 7,38 8.49 8,49 11.3 11,3 14.8 14,8 16.2 16,2 22.6 22,6 4.56 4,56 7.01 7,01 8.98 8,98 10.7 10,7 14.10 14,10 17.3 17,3 21.4 21,4 2.41 2,41 2.32 2,32 2.47 2,47 2.21 2,21 2.3 2,3 2.5 2,5 2.2 2,2 2.61 2,61 2.64 2,64 2.67 2,67 2.52 2,52 2.62 2,62 2.66 2,66 2.52 2,52 1,230x1,290x734 1.230x1.290x734 1,450x1,290x734 1.450x1.290x734 1,321x2,580x734 1.321x2.580x734 1,541x2,580x734 1.541x2.580x734 163 181 193 227 241 253 258 272 284 258 272 284 455 473 485 516 534 546 516 534 546 165 184 252 230 244 312 261 275 343 261 275 343 461 482 550 522 544 612 522 544 612 Brazed plate 1.140 1,140 1.615 1,615 1.900 1,900 2.375 2,375 2.964 2,964 3.900 3,900 4.524 4,524 26 49 60 72 98 115 143 34 53 69 77 106 132 155 10 25 24 33 12 19 17 29 31 38 14 16 22 Cross fin coil/Hi-X tubes and PE coated waffle louvre fins 12 12 12 12 12 12 12 160 (per 2 fans) 170 (per 2 fans) 170 (per 2 fans) 67 76 78 79 81 Hermetically sealed scroll compressor -10(OPZL) ~ 20 35 ~ 50 -15 ~ 43 -10 ~ 21 R-407C Thermostatic expansion valve 1 2 4.6 4,6 4.7 4,7 5.4 5,4 5.1 5,1 5.4 5,4 5.6 5,6 5.1 5,1 5.4 5,4 5.6 5,6 G 1"1/4 (male) 2" male 3N~ / 50 / 400
40
EWYQ-BAWN/BAWP
Air cooled heat pump inverter chiller EWYQ-BA*
BRC21A52
›› ›› ›› ›› ›› ›› ››
High efficiency chiller with leader-of-class ESEER (up to 4.75) Minimal starting currents and short payback times No buffertank required for standard applications Naked or with factory mounted (standard/high-ESP) pump Low sound thanks to inverter compressor / fans EWYQ-BAWN: Naked EWYQ-BAWP: With pump
Heating & Cooling Capacity class Cooling capacity Heating capacity Capacity control Power input EER ESEER COP Dimensions Weight
Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Heating Nominal water pressure drop Cooling Total Air heat exchanger Type Fan Air flow rate Cooling Nom. Heating Nom. Sound power level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Heating Min.~Max. Air side Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping connections Water inlet / outlet Power supply Phase/Frequency/Voltage
kW kW % kW kW
016 16.8 16.8
5.57 5.51 3.01 4.75 3.05
mm kg kg
264 267
l l/min l/min kPa
48 48 20
m³/min m³/min dBA
021 21.0 21.0
025 25.2 25.2
7.25 7.09 2.90 4.65 2.96 1,684x1,371x774 317 320 1 60 60 30
171 171
185 185 78
°CDB °CDB °CDB °CDB kg
7.6
inch Hz/V
1-1/4”
41
032 040 050 31.5 42.0 50.4 31.5 42.0 50.4 Inverter controlled 25 9.25 12.9 14.9 19.0 8.87 10.5 14.2 17.8 2.72 2.44 2.82 2.65 4.45 4.00 4.60 4.40 2.84 3.00 2.96 2.83 1,684x1,684x774 1,684x2,358x780 397 571 401 577 Brazed plate 2 3 72 90 120 144 72 90 120 144 42 30 42 Hi-XSS 233 370 233 370 80 81 Hermetically sealed scroll compressor -10~20 25~50 -15~43 -15~35 R-410A 9.6 15.2 Electronic expansion valve 1 1-1/2" 3N~/50/400
064 63.0 63.0
26.7 21.0 2.36 3.95 3.00 1,684x2,980x780 730 738 5 181 181 30 466.0 466 83
19.2
EWYQ-DAYN
Air cooled heat pump chiller, multiple scroll EWYQ130-150DAYN
PCASO
›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ››
Optimised for use with R-410A refrigerant Multiple compressors per circuit Reliable and efficient scroll with high EER values High part load efficiency (ESEER) Anti-corrosion treated aluminium coils Low operating sound level Easy 'plug and play' installation Fans protected against abnormal operation (4 - 8 fans depending on unit size) Safety valves in each circuit Electronic circuit breakers Electronic expansion valve True dual plate brazed plate heat exchanger All hydronics can be accessed easily from 3 sides (no surrounding cabinet) Separate switchbox for easy access Compressors and controls at unit side Increased reliability via 2 independent refrigerant circuits (EWYQ130-250DAYN) Double circuit heat exchanger (from >100 kW) Non hermetic filter/dryer Daikin Pcaso controller with user friendly and powerful LCD interface
Heating & Cooling Capacity class Cooling capacity Heating capacity Capacity steps
Power input EER COP ESEER Dimensions Weight Water heat exchanger
Air heat exchanger Fan Sound power level Compressor Operation range
Refrigerant
Refrigerant circuit Refrigerant circuit 2 Piping connections Power supply
Nom. Nom.
Cooling Heating
kW kW %
Nom. Nom.
HeightxWidthxDepth Unit Unit Operation weight Type Nominal water Cooling flow Heating Nominal water Cooling Total pressure drop Heating Total Type Air flow rate Nom. Speed Cooling Nom. Type Water side Cooling Min.~Max. Water side Heating Min.~Max. Air side Cooling Min.~Max. Air side Heating Min.~Max. Type Control Circuits Quantity Charge Charge Water inlet / outlet Water drain Phase / Frequency / Voltage
kW kW
mm kg kg l/min l/min kPa kPa
080 77 87.7
100 100 114
130 136 149
180 210 183 211 199 225.00 21/290-25-50-75-100 43/50/570-25-50-75-100 71/79-100 47.6 55.7 63.8 75.3 49.6 58.8 68.0 77.0 2.86 2.60 2.87 2.80 3.00 2.81 2.93 2.92 4.31 4.07 4.33 4.23 2,311x2,000x2,631 2,311x2,000x3,081 1,550 1,600 1,850 1,900 1,567 1,619 1,875 1,927 Brazed plate, one per unit 390 416 525 605 427 473 570 645 43 38 41 44 51 49 48 50 Cross fin coil/Hi-Xss tubes and poly ethylene coated waffle fins 800 860 1,290 900 970 88 89 90 Scroll compressor -10 (OPZL) ~ 25 25 ~ 50 -15 ~ 43 -10 ~ 21 R-410A Electronic expansion valve 2 22 32 22 32 3" OD 1/2"G 3~ / 50 / 400
0-50-100 26.5 36.2 30.0 38.1 2.91 2.76 2.92 2.99 4.00 3.81 2,311x2,000x2,566 1,400 1,450 1,415 1,465 221 251
287 327 36
47
m³/min rpm dBA
46 780 880 86
°CDB °CDB °CDB °CDB
1 kg kg inch inch Hz / V
33
37 -
42
150 145 165
230 250 231 252 258 281 22/2844/50/560-25-50-75-100 72/78-100 82.2 93.5 84.2 96.6 2.81 2.70 3.06 2.91 4.20 4.00 2,311x2,000x4,850 3,200 3,300 3,239 3,342 662 740 39 48
722 806 38 46 1,600 900 91
39 39 3"
EWYD-BZSS
Air cooled heat pump inverter chiller, standard efficiency, standard sound EWYD250BZSS
PCO2
›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ››
Optimised for use with R-134a Cooling range: 254-583kW Heating range: 270-615kW EER range up to 2.83 Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops Low starting current No gas boiler required Optimised defrost cycles Optimum ESEER values Partial heat recovery option available PID microprocessor control Power factor up to 0.95 2-3 truly independent refrigerant circuits Standard operation range down to -12 °C
Standard efficiency Standard sound
Heating & Cooling Capacity class Cooling capacity Heating capacity Capacity control Power input EER COP ESEER Dimensions Weight
Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Heating Nominal water Cooling Heat exchanger pressure drop Heating Heat exchanger Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Heating Nom. Sound pressure level Cooling Nom. Heating Nom. Compressor Type Operation range Water side Cooling Min.~Max. Water side Heating Min.~Max. Air side Cooling Min.~Max. Air side Heating Min.~Max. Refrigerant Type Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage
kW kW % kW kW
mm kg kg l l/s l/s kPa kPa
250 254 270
270 273 297
290 292 324
90.3 100 109 90.4 99 107 2.81 2.74 2.69 2.98 2.99 3.03 4.05 4.04 4.01 2,335x2,254x3,547 3,410 3,455 3,500 3,550 3,595 3,640
320 324 333
138 13.03 14.18
13.94 15.49
37
42
48
53
42
49
58
55
100.5 100.5 82.1 82.1
94
410 413 443
440 436 463
460 457 475
510 505 530
161 164 2.83 2.90 4.31
178 176 2.83 3.02
100
mm Hz / V
43
520 522 558
580 583 615
186 184 2.81 3.04
215 205 2.71 3.00 4.05
9
5,015 5,255
4.13 2,335x2,254x6,583 5,495 5,735 5,724 5,964 5,953
240 21.83 22.68
24.11 25.33
24.92 26.65
218 27.87 29.39
229
58
53
57
46
51
61
50
53
65
60
57
65
52
57
66
55
60
71
High efficiency fin and tube type with integral subcooler 42,304 52,880 920 101.2 101.8 101.2 101.8 82.3 82.5 82.3 82.5 Semi-hermetic single screw compressor -8~15 35~55 -10~45 -12°C~20 R-134a 118 121 124 148 177 2 139.7 3~ / 50 / 400
31,728
88
380 382 410 Stepless
13 124 134 142 152 163 124 132 141 155 165 2.74 2.73 2.68 2.72 2.68 2.80 2.87 2.90 2.85 2.81 4.01 4.02 3.94 4.03 4.01 2,335x2,254x4,381 2,335x2,254x5,281 3,870 3,940 4,010 4,390 4,010 4,068 4,138 4,518 Single pass shell & tube 133 128 15.46 16.21 17.42 18.25 19.72 20.81 15.89 16.66 18.11 19.57 21.15 22.14
°CDB °CDB °CDB °CDB kg
370 365 379
116 117 2.79 2.84 4.07
12.12 12.89
l/s rpm dBA dBA dBA dBA
340 339 349
63,456 103.6 103.6 83.7 83.7
183
186 3 219.1
EWYD-BZSL
Air cooled heat pump inverter chiller, standard efficiency, low sound EWYD250BZSL
PCO2
›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ››
Optimised for use with R-134a Cooling range: 248-567kW Heating range: 270-615kW EER range up to 2.87 Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops Low operating sound level Low starting current No gas boiler required Optimised defrost cycles Optimum ESEER values Partial heat recovery option available PID microprocessor control Power factor up to 0.95 2-3 truly independent refrigerant circuits Standard operation range down to -12°C
Standard efficiency Low sound
Heating & Cooling Capacity class Cooling capacity Heating capacity Capacity control Power input EER COP ESEER Dimensions Weight
Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume Nominal water Cooling flow Heating Nominal water Cooling Heat exchanger pressure drop Heating Heat exchanger Air heat exchanger Type Fan Air flow rate Cooling Nom. Heating Nom. Fan motor Speed Cooling Nom. Heating Nom. Sound power level Cooling Nom. Heating Nom. Sound pressure Cooling Nom. level Heating Nom. Compressor Type Operation range Water side Cooling Min.~Max. Water side Heating Min.~Max. Air side Cooling Min.~Max. Air side Heating Min.~Max. Refrigerant Type Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage
kW kW % kW kW
mm kg kg l l/s l/s kPa kPa
250 248 270
270 266 297
290 291 324
88.5 98 109 90.4 99 107 2.80 2.70 2.66 2.98 2.99 3.03 4.18 4.16 4.11 2,335x2,254x3,547 3,750 3,795 3,840 3,888 3,933 3,978
320 316 333
138 12.70 14.18
13.89 15.49
36
40
48
51
42
49
58
55
94.0 94.9 75.6 76.5
94
400 403 443
430 425 463
450 448 475
156 164 2.87 2.90 4.31 5,525 5,765
100
mm Hz / V
44
490 493 530
510 510 558
570 567 615
9 174 183 214 176 184 205 2.83 2.79 2.65 3.02 3.04 3.00 4.29 4.23 4.10 2,335x2,254x6,583 6,005 6,245 6,234 6,474 6,463
240 21.39 22.68
23.56 25.33
24.34 26.65
218 27.11 29.39
229
55
50
55
44
48
59
48
51
62
60
57
65
52
57
66
55
60
71
High efficiency fin and tube type with integral subcooler 32,576 40,720 42,304 52,880 715 920 94.7 95.3 96.1 96.7 75.8 76.0 77.2 77.4 Semi-hermetic single screw compressor -8~15 35~55 -10~45 -12°C~20 R-134a 118 121 124 148 177 2 139.7 3 ~/ 50 / 400
24,432 31,728
88
370 372 410 Stepless
13 122 132 142 149 161 124 132 141 155 165 2.72 2.68 2.62 2.71 2.64 2.80 2.87 2.90 2.85 2.81 4.18 4.16 4.13 4.19 4.14 2,335x2,254x4,381 2,335x2,254x5,281 4,210 4,280 4,350 4,730 4,343 4,408 4,478 4,858 Single pass shell & tube 133 128 15.12 15.83 16.98 17.77 19.28 20.30 15.89 16.66 18.11 19.57 21.15 22.14
°CDB °CDB °CDB °CDB kg
360 355 379
113 117 2.79 2.84 4.29
11.83 12.89
l/s l/s rpm rpm dBA dBA dBA dBA
330 331 349
48,864 63,456
97.0 98.4 77.2 78.6
183
186 3 219.1
The Daikin condensing units can be used in a wide variety of air conditioning, refrigeration and ventilation applications.
condensing units ERQ VRV速-AHU ERAD-E-SS ERAD-E-SL
46 48 50 51
PIPING DIAGRAM FOR COMFORT COOLING APPLICATION
Air handling unit
Condensing Unit
1. Switchbox 2. Thermistor line
45
ERQ
›› ›› ›› ›› ›› ›› ›› ›› ››
Heat-pump condensing unit
Highly efficient cooling and heating solution for air handling applications Saves on installation costs – no water piping, freezing protection, chillers or boilers needed to satisfy the fresh air heating and cooling loads Daikin Inverter technology for step-less and efficient capacity control ensuring constant and comfortable supply air temperature Wide capacity regulation range – down to 18% nominal capacity on size 250 Wide operation range – in heating down to -20°C and in cooling up to +43°C ambient temperature Flexible choice of regulations, from plug&play Daikin regulation, to sophisticated external control Wide range of options, such as low noise mode or externally-controlled power input limiting R410A direct expansion system for connection to external air heat exchangers
Expansion valve kit EKEXV
ERQ
Air handling unit
Liquid pipe
Gas pipe
Expansion valve control Thermistors
Daikin communication
Control box EKEQDCB EKEQFCB
Controller (Daikin or External)
46
ERQ
Heat-pump condensing unit
Heat pump ERQ100AV1
OUTDOOR UNITS Nominal Capacity * EER COP Combinable expansion valves Operation range - outdoor ERQ-AV1
Operation range on-coil indoor Sound power level Sound pressure level
ERQ125AW1
Defrost method Dimensions
Weight Refrigerant Piping dimensions
ERQ200~250AW1
Piping length Power supply Recommended fuses
Cooling Heating
kW kW
EKEXV # Cooling Heating Cooling Heating Cooling Heating Cooling Heating
°CDB °CWB °C °C dBA dBA dBA dBA
Height Width Depth
mm mm mm kg
R410A Liquid (OD) mm Gas (OD) mm Maximum m A
Expansion valve kits Nominal heat exchanger capacity* Heat exchanger inner volume Dimensions
EKEXV
Weight Sound pressure level Piping connections
minimum maximum minimum maximum Height Width Depth
In (OD) Out (OD)
kW kW l l mm mm mm kg dBA mm mm
ERQ125AV1
EKEQFCB
Regulation range
Inputs & Outputs
Daikin Remote Controller Dimensions
Weight Power supply
BRC1D52 / BRC1E51A Height mm Width mm Depth mm kg
Options/Accessories Electromechanical cool/heat selector (switch) Fixing box for cool/heat selector Drain pan kit with central drain outlet Daikin Remote Controller Adaptor for ext. monitoring/control External room temperature sensor
KRC19-26 KJB111A KWC26B160 KWC26B280 BRC1D52 / BRC1E51A KRP4A51 KRCS01-1
ERQ125AW1
14 15.5 16 18 3.99 3.42 4.15 3.94 63 ~ 140 80 ~ 140 -5 ~ +46 -20 ~ +15,5 +14 WB ~ +25 WB / +35 DB +10 DB ~ 27 DB 66 67 69 – – – 50 51 53 52 53 55 Reverse cycle, electronically controlled 1.345 900 320 120 4 9.52 9.52 9.52 15.9 15.9 19.1 55 1~ / 230V / 50Hz 32
ERQ200AW1
ERQ250AW1
14 16 3.98 4 63 ~ 140
22.4 28 25 31.5 4.29 3.77 4.5 4.09 100 ~ 250 125 ~ 250 -5 ~ +43 -20 ~ +15 +14 WB ~ +25 WB / +35 DB +10 DB ~ 27 DB 72 78 78 – – – 54 57 58 – – – Reverse cycle, electronically controlled 1.68 1.68 1.68 635 930 930 765 765 765 159 187 240 6.2 7.7 8.4 9.52 9.52 9.52 15.9 19.1 22.2 55 3N~ / 400V / 50Hz 16 25 25
EKEXV63
EKEXV80
EKEXV100
EKEXV125
EKEXV140
EKEXV200
EKEXV250
6.3 7.8
7.9 9.9
10 12.3
12.4 15.4 1.66 8.25 457 270 120 2.9 45 9.52 9.52
15.5 17.6
17.7 24.6
24.7 30.8
EKEQDCB
EKEQFCB
Daikin control Room temperature control [via Remote Controller (accessory) or via External room temperature sensor (accessory)]
Free (External) control 0~10V direct capacity control (5V = maintain capacity, >5V colder air wanted, <5V warmer air wanted)
Return air temperature control (via a supplied thermistor) Setpoint 16 ~ 32°C via Daikin Remote Controller (accessory)
On / Off potential free input Fan Control potential free output (e.g. to stop AHU during hot-start and defrost)
Fixed evaporation / condensation temperature control 0~10V input from external controller Fixed evaporation temperature setting to 5 ~ 12°C Fixed condensation temperature setting to 43 ~ 49°C On / Off potential free input Fan Control potential free output (e.g. to stop AHU during hot-start and defrost)
Operation / Error output possible by accessory (KRP4A51)
Defrost potential free output (e.g. to stop AHU during hot-start and defrost)
CONTROL BOXES Control type Control options
ERQ140AV1
11.2 12.5 3.99 4.56 63 ~ 125
Compressor operation potential free output Error indication potential free output Required for end-user control (order separatelly) Required for commissioning & service (order separatelly) 132 400 200 3.6 3.9 1~ / 230V / 50Hz
ERQ-AV1
ERQ125AW1
ERQ200.250AW1
• •
• • •
• •
EKEQDCB
EKEQFCB
• • •
•
•
47
EKEQMCB VRV® air handling applications
›› Integrated air conditioning and air handling solution from one supplier ›› Connect any Air Handling Unit to any VRV® –– Even geothermal-sourced VRV® WIII possible ›› Efficiency of DX system both for cooling and for heating ›› Unique application for Daikin VRV® III Heat Recovery with continuous heating during defrost EKEXV-kit
EKEQMCB
gas pipe liquid pipe F1-F2 other communication
CONTROL BOXES
EKEQMCB
Control type Control options
Daikin control Room temperature control [via Remote Controller (accessory) or via External room temperature sensor (accessory)] Return air temperature control (via a supplied thermistor) Setpoint 16 ~ 32°C via Daikin Remote Controller (accessory) On / Off potential free input Fan Control potential free output (e.g. to stop AHU during defrost) Operation / Error output possible by accessory (KRP4A51)
Regulation range Inputs & Outputs
Daikin Remote Controller Dimensions
BRC1D52 BRC1E51A Height Width Depth
Weight Power supply
Expansion Valve Kits Allowed heat Cooling exchanger (evaporation capacity temp. 6°C) Heating (condensing temp. 46°C) Dimensions Weight Sound pressure level Operation range
Unit Unit Nom. Cooling Heating Operation range - Cooling on coil temperature Heating Refrigerant Type Piping Liquid connections Gas 1 2
Required for end-user control (order separatelly) 132 400 200 3.6 1~ / 230V / 50Hz
mm mm mm kg
Minimum Standard Maximum Minimum Standard Maximum HeightxWidthxDepth
Min./Max. Min./Max. Max. Min.
kW kW kW kW kW kW mm kg dBA °CDB °CWB °CDB °CDB
OD OD
mm mm
EKEXV50 5.0 5.6 6.2 5.6 6.3 7.0
EKEXV63 6.3 7.1 7.8 7.1 8.0 8.8
EKEXV80 7.9 9.0 9.9 8.9 10.0 11.1
6.35 6.35
45% relative humidity The temperature of the air entering the coil in heating mode can be reduced to -5°CDB. Contact your local dealer for more information
48
EKEXV100 EKEXV125 10.0 12.4 11.2 14.0 12.3 15.4 11.2 13.9 12.5 16.0 13.8 17.3 401x215x78 2.9 45 -5.0/46.0 -/351 102 R-410A 9.52 9.52
EKEXV140 15.5 16.0 17.6 17.4 18.0 19.8
EKEXV200 17.7 22.4 24.6 19.9 25.0 27.7
EKEXV250 24.7 28.0 30.8 27.8 31.5 34.7
ERAD-E-SS
Air cooled condensing unit, standard efficiency, standard sound ERAD170,200E-SS
MicroTech III
›› ›› ›› ›› ›› ››
Wide capacity range (121 kW - 488 kW) Single refrigerant circuit with steppless single screw compressor Compact design Large operation range (ambient temperature down to -18°C) Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications
Standard efficiency Standard sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER Dimensions Weight
Nom. Method Minimum capacity Cooling Nom.
HeightxWidthxDepth Unit Unit Operation weight Air heat exchanger Type Fan Air flow rate Nom. Fan motor Speed Cooling Nom. Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Saturated suction temp. Min-Max Condenser Min-Max Refrigerant Type Charge Circuits Quantity Power supply Phase / Frequency / Voltage
kW % kW mm kg kg l/s rpm dBA dBA
120 121
140 144
170 165
220 219
250 252
310 306
370 370
440 435
490 488
Stepless 25 41.8 51.0 2.90 2.83 2,273x1,292x2,165 1,584 1,617 10,922
10,575 91.5
57.4 65.2 73.7 76.6 92.8 122.0 147.2 160.8 2.87 3.00 2.97 3.28 3.30 3.04 2.96 3.03 2,273x1,292x3,065 2,273x1,292x3,965 2,223x2,236x3,070 1,741 1,936 2,679 1,781 1,981 2,756 High efficiency fin and tube type with integral subcooler 16,383 15,863 21,844 21,150 32,767 31,725 920 92.3 93.0 94.2 94.5 95.2
73.5
73.7
°C °C kg
200 196
17
20
22
Hz / V
50
73.9
75.1
75.0
Semi-hermetic single screw compressor -9~12 -18~48 R-134a 27 29 32 1 3~ / 50 / 400
75.3
45
76.0
54
58
ERAD-E-SL
Air cooled condensing unit, standard efficiency, low sound ERAD160,190E-SL
MicroTech III
›› ›› ›› ›› ›› ›› ››
Low operating sound level Wide capacity range (116 kW - 462 kW) Single refrigerant circuit with steppless single screw compressor Compact design Large operation range (ambient temperature down to -18°C) Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications
Standard efficiency Low sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER Dimensions Weight
Nom. Method Minimum capacity Cooling Nom.
HeightxWidthxDepth Unit Unit Operation weight Air heat exchanger Type Fan Air flow rate Nom. Fan motor Speed Cooling Nom. Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Saturated suction temp. Min-Max Condenser Min-Max Refrigerant Type Charge Circuits Quantity Power supply Phase / Frequency / Voltage
kW % kW mm kg kg l/s rpm dBA dBA
120 116
140 137
160 159
210 209
240 243
300 295
350 352
410 409
460 462
Stepless 25 42.3 52.5 2.74 2.61 2,273x1,292x2,165 1,684 1,717 8,372
8,144 89.0
57.6 66.3 73.9 78.2 91.5 122 150 167 2.75 2.82 2.83 3.11 3.23 2.88 2.73 2.76 2,273x1,292x3,065 2,273x1,292x3,965 2,223x2,236x3,070 1,841 2,036 2,789 1,881 2,081 2,886 High efficiency fin and tube type with integral subcooler 12,558 12,217 16,744 16,289 25,117 24,433 715 89.8 90.5 91.7 92.0 92.7
71.0
71.2
°C °C kg
190 187
17
20
22
Hz / V
51
71.4
72.6
72.5
Semi-hermetic single screw compressor -9~12 -18~48 R-134a 27 29 32 1 3~ / 50 / 400
72.8
45
73.5
54
58
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13.
Balancing valve Pressure gauge Temperature sensor Drain valve Shut-off valve Charging valve Filter Air purge Safety valve Pressure port Pump Flow switch Bypass valve
water cooled chiller 3 12
2
9
10
8
3
Chillers
Buffer tank
5
Expansion vessel
5
7
Buffer tank
Condenser
6 4
Evaporator
5
11
1
To fan coil units or thermal load
4 6
Expansion vessel
3
11 8
9
13
10
5
7
5
3 12
52
3
1 2
To fan coil units or thermal load
5
Daikin offers you compact water-cooled chiller units which require only very limited space in a machine room. Used for commercial or industrial applications, these chillers generate cold and hot water, which can be used for chilling, heating, or even both at the same time.
water-cooled chillers NEW
NEW NEW NEW
EWWP-KBW1N EWWD-J-SS EWWD-G-SS EWWD-G-XS EWWD-I-SS EWWD-I-XS EWWD-H-XS EWWQ-B-SS EWWQ-B-XS EWWD-FZXS DWSC, DWDC
54 56 58 59 60 61 62 64 65 66 68
53
EWWP-KBW1N
Water cooled chiller EWWP014-035KBW1N
μC² SE
›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ››
Standard integrated: main switch, water filter, flow switch, air purge, pressure ports Daikin scroll compressor Optimised for use with R-407C Low operating sound level Low energy consumption Extension possible up to 195kW Compact dimensions and low refrigerant volume Easy installation and maintenance Stainless steel plate heat exchanger Remote cooling or heating selection Water/water heat pump, with water reversibility Compatible with hydraulic module EHMC µC² SE DDC controller pCO3 DDC controller for assembly of 2 or 3 modules
Heating only & Cooling only Capacity class Cooling capacity Nom. Heating capacity Nom. Capacity steps number Power input Cooling Nom. EER HeightxWidthxDepth Dimensions Unit Weight Unit Water heat Type exchanger Minimum water volume in the system evaporator Water flow rate Min. Nom. Max. Water heat Type exchanger Water flow rate Min. condenser Nom. Max. Sound power level Cooling Nom. Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Control Circuits Quantity Refrigerant circuit Charge Piping Evaporator water inlet/outlet connections Evaporator water drain Condenser water inlet/outlet Condenser water drain Power supply Phase / Frequency / Voltage
kW kW
014 13.0 16.6
022 21.5 27.3
028 28.0 35.4
035 32.5 41.2
mm kg
1 5.79 7.48 8.75 3.71 3.74 3.71 600x600x600 118 155 165 172
l l/min l/min l/min
62 19 37 75
103 31 62 123
134 40 80 161
155 47 93 186
l/min l/min l/min dBA
24 48 95
39 78 157 64
51 102 203
59 118 237 71
kW
3.61 3.60
°CDB °CDB
kg mm mm Hz / V
1.2
1 2 2.5 FBSP 25 FBSP 25
3.1
045 43.0 54.8
055 065 56.0 65.0 71.4 82.7 2 11.80 15.50 17.60 3.64 3.61 3.69 600x600x1,200 300 320 334
110 120 130 112 121 130 143 154 165 4 23.6 27.3 31.0 33.1 35.2 3.64 3.63 3.61 3.66 3.69 1,200x600x1,200 600 620 640 654 668 Brazed plate 205 268 311 205 268 311 62 80 93 123 142 161 173 186 123 161 186 247 284 321 347 373 247 321 373 493 568 642 694 745 Brazed plate 79 102 118 157 181 205 221 237 157 205 237 314 362 410 442 474 314 410 474 629 724 819 883 948 67 74 71 75 77 Hermetically sealed scroll compressor -10 (OPZL) ~ 25 20 ~ 55 R-407C Thermostatic expansion valve 2 4 4.6 5.6 9.2 10.2 11.2 FBSP 40 2 x 2 x FBSP 38 Field installation FBSP 40 2 x 2 x FBSP 38 Field installation 3N~ / 50 / 400
54
090 86.0 110
100 99.0 126
145 142 181
155 155 198
39.1 3.63
42.8 3.62
920
165 168 214
175 177 226
185 186 237
6 46.5 48.6 50.7 3.61 3.64 3.67 1,800x600x1,200 940 960 974 988
205 204 222 407 444 814 889
195 195 248 52.8 3.69 1.002
268 311 254 267 280 507 533 559 1,015 1,066 1,118
241 482 963
260 283 307 323 339 355 519 567 614 647 679 711 1,038 1,133 1,229 1,293 1,357 1,422 73 76 78 79
6 13.8
14.8 15.8 3 x 2 x FBSP 38 3 x 2 x FBSP 38
16.8
EWWP-KBW1N
Water cooled chiller
EWWP014-035KBW1N
EWWP090-130KBW1N
EWWP145-195KBW1N
1 MODULE (KB-SERIES)
SELECTION TABLE
2 MODULES (KB-SERIES)
3 MODULES (KB-SERIES)
Capacity index
014
022
028
035
045
055
065
090
100
110
120
130
145
155
165
175
185
195
Cooling capacity (kW)
13.0
21.5
28.0
32.5
43.0
56.0
65.0
86.0
99.0
112
121
130
142
155
168
177
186
195
16.6
27.3
35.4
41.2
54.8
71.4
82.7
110
126
143
154
165
181
198
214
226
237
248
1 -
1 -
1 -
1 -
1 -
1 -
1 -
2 1 -
1 1 1 -
2 1 -
1 1 1 -
2 1 -
2 1 1
1 2 1
3 1
2 1 1
1 2 1
3 1
Heating capacity (kW)
UNIT + CONTROL (Factory mounted)
MODULAR UNITS (Controller available as accessory) CONTROL (kit) For example:
EWWP014KBW1N EWWP022KBW1N EWWP028KBW1N EWWP035KBW1N EWWP045KBW1N EWWP055KBW1N EWWP065KBW1N EWWP045KAW1M EWWP055KAW1M EWWP065KAW1M ECB2MUW ECB3MUW
for a 121 kW HP system, select : EWWP055KBW1N + EWWP065KBW1N
55
EWWD-J-SS
Water cooled chiller, standard efficiency, standard sound EWWD-J-
MicroTech III
›› ›› ›› ›› ›› ››
Compact design to allow easy indoor installation or retrofit operations Stepless single screw compressor High efficiency at full and partial load Chilled water temperatures down to -10°C on standard unit Optimised for use with R-134a MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications
Standard efficiency Standard sound
Heating only & Cooling only Capacity class Cooling capacity Heating capacity Capacity control Power input EER ESEER COP Dimensions Weight Water heat exchanger Water heat exchanger evaporator Water heat exchanger condenser Sound power level Sound pressure level Compressor Operation range Refrigerant
Piping connections Power supply
120 120 142
140 146 172
150 155 188
180 178 216
210 208 249
Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom.
kW kW
HeightxWidthxDepth Unit Unit Operation weight Type Water volume Nominal water pressure drop Cooling Heat exchanger Type Water flow rate Nom. Nominal water pressure drop Cooling Cooling Nom. Cooling Nom. Type Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Type Charge Circuits Quantity Evaporator water inlet/outlet Condenser water inlet/outlet Phase/Frequency/Voltage
mm kg kg
1,177 1,211
l kPa
14 15
18 13
14 40
17 38
20 36
l/s kPa dBA dBA
7.04 20
8.57 12
9.25
10.62 11
12.30
% kW kW
27.3 32.9 4.40 5.01 4.32
25 33.3 38.5 44.2 49.3 59.57 40.1 46.4 53.5 4.38 4.03 4.22 4.67 4.66 4.75 4.29 4.05 4.04 4.18 1,020x913x2,684 1,233 1,334 1,366 1,416 1,276 1,378 1,415 1,473
88.6 71.4
°CDB °CDB kg
18
mm inch Hz/V
2.5
20
33
34 1
36
250 256 305
280 285 340
310 330 310 334 377 405 Stepless
58.7 71.68 4.37 5.20 4.26
68.3 80.75 4.18 4.46 4.21
77 92.88 4.03 4.80 4.06
82.7 88.4 99.9 107 4.04 4.84 5.00 4.05 4.04
1,600 1,663
380 386 466
4 3~/50/400
400 416 499
450 464 554
12.5 98.6 108 113 119 131 3.91 4.22 4.30 4.79 5.17 5.27 4.12 4.19 4.22 2,000x913x2,684 2,782 2,832 3,016 2,888 2,946 3,136
1,607 2,668 2,700 2,732 1,675 2,755 2,792 2,830 Brazed plate, one per circuit 26 29 31 33 37 28 33 40 38 Double pass shell and tube 15.06 16.89 18.49 19.91 21.28 23.15 16 26 11 87.2 92.4 70.0 74.4 Semi-hermetic single screw compressor -10~15 23~60 R-134a 38 66 67 68 70 76.2
56
360 357 432
41
500 513 610
530 541 645
560 570 681
117 143 4.38 5.37 4.26
127 152 4.26 5.25 4.23
137 162 4.16 4.81 4.22
3,200 3,327
3,207 3,338
3,215 3,350
46
52
36 24.59
28 27.33
30.10
33 31.92
16
72 2
91.8 73.8
91.0 73.0
74
76
33.78 26
EWWD-G-SS
Water cooled chiller EWWD-G-
MicroTech III
›› ›› ›› ›› ›› ›› ›› ›› ›› ››
High efficiency (XS) All models are PED pressure vessel approved Stepless single-screw compressor Optimised for use with R-134a EER range up to 4 (SS) , 4.73 (XS) 1-2 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side for easy oil circulation and return Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications
Standard efficiency Standard sound
Heating only & Cooling only Capacity class Cooling capacity Heating capacity Capacity control Power input EER COP ESEER Dimensions Weight
Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume evaporator Nominal water Cooling Total pressure drop Water heat Type exchanger Water flow rate Nom. condenser Nominal water Cooling pressure drop Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping Evaporator water inlet/outlet connections Condenser water inlet/outlet Power supply Phase / Frequency / Voltage
kW kW
170 166 204
210 201 247
260 253 310
300 280 343
320 334 410
380 372 456
420 403 494
460 448 552
500 494 610
600 556 674
129 161 3.83 3.79 5.1
150 177 3.70 3.81 4.93
Stepless % kW kW
mm kg kg l kPa
l/s kPa
25 42.2 52.7 3.93 3.87 5.00
50.6 64.9 75.3 63.5 80.8 89.2 3.97 3.90 3.72 3.89 3.84 5.04 4.95 4.72 1,860x920x3,435 1,410 1,503 1,480 1,650
1,393 1,470 60
56
48
69
123 43
53
9.95
12.02
15.19
16.98
39
41
63
77
dBA dBA
93 117 4.00 3.91 5.33
2,687 2,697 2,840 2,850 Single pass shell and tube 118 113 64
63
168 54
24.08
41
68
26.90
29.77
33.73
57
60
75
90.2
69.7
71.7
50
55
Semi-hermetic single screw compressor -8~15 20~55 R-134a 110 50 Electronic expansion valve
1 mm inch Hz / V
2,762 2,970
173 72
Single pass shell and tube 19.99 22.22 40
12.5 101 115 127 144 3.97 3.89 3.89 3.84 5.29 5.19 1,880x860x4,305 2,702 2,757 2,860
87.7
°CDB °CDB kg
84.3 106 3.96 3.88 5.28
55
110
2
88.9
114.3 5 3~ / 50 / 400
58
139.7
EWWD-G-XS
High efficiency Standard sound
Heating only & Cooling only Capacity class Cooling capacity Heating capacity Capacity control Power input EER COP ESEER Dimensions Weight
Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume evaporator Nominal water Cooling Total pressure drop Water heat Type exchanger Water flow rate Nom. condenser Nominal water Cooling pressure drop Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping Evaporator water inlet/outlet connections Condenser water inlet/outlet Power supply Phase / Frequency / Voltage
kW kW
190 186 220
230 223 264
280 277 326
320 307 354
380 366 434
400 408 482
460 444 524
87.2 110 4.68
95.1 120 4.67
500 496 585
550 541 638
650 604 712
115 144 4.72 4.43 6.30
137 162 4.39 4.40 5.85
Stepless % kW kW
mm kg kg l kPa
l/s kPa dBA dBA
25 39.6 50.1 4.70 4.38 5.97 1,650 1,800 125
12.5
48.1 59.4 60.6 74.5 4.64 4.66 4.35 4.38 5.9 5.92 1,860x920x3,435 1,665 1,680 1,810 1,820 120
25
110 35
44
10.78
12.95
16.07
18.08
17
20
25
28
mm inch Hz / V
79.2 99.9 4.62 4.34 6.15
105 132 4.73 4.38 4.42 6.24 6.23 6.31 1,880x860x4,305 2,800 2,945 2,955 2,975 3,020 3,280 3,290 3,315 Single pass shell and tube 170 285 30
24
Single pass shell and tube 21.27 23.66
2,990 3,340 280
28
39
46
57
25.76
28.71
31.34
35.40
16
15
19
17
88.2
90.9
69.7
71.7 Semi-hermetic single screw compressor -8~15 20~55 R-134a 110 105 Electronic expansion valve
째CDB 째CDB kg
71.4 83.7 4.30 4.23 5.46
55 1 114.3
100 2
139.7 5 3~ / 50 / 400
59
168.3
EWWD-I-SS
Water cooled chiller EWWD-I-
MicroTech III
›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ››
High efficiency (XS) All models are PED pressure vessel approved Stepless single-screw compressor Optimised for use with R-134a Cooling range: 333–1,510kW (SS) , 362-1.134kW (XS) EER range: 4.28 to 4.66 (SS) , 4.73 to 5.10 (XS) 1-2-3 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications
Standard efficiency Standard sound
Heating only & Cooling only Capacity class Cooling capacity Heating capacity Capacity control Power input EER COP ESEER Dimensions Weight
Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume evaporator Nominal water Cooling Heat exchanger pressure drop Water heat Type exchanger Water flow rate Nom. condenser Nominal water Cooling pressure drop Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Control Circuits Quantity Refrigerant circuit Charge Evaporator water inlet/outlet Piping connections Condenser water inlet/outlet Power supply Phase / Frequency / Voltage
kW kW % kW kW
mm kg kg l kPa
l/s kPa dBA dBA
340 333 388.4
900 950 C10 C12 C13 C14 C15 C16 C17 910 986 1,027 1,155 1,204 1,274 1,346 1,401 1,455 1,072 1,161 1,217 1,363 1,427 1,507 1,227 1,661 1,730 Stepless 25 12.5 8.3 71.5 85.8 101 120 141 156 171 186 200 218 237 254 268 282 298 317 335 87.4 104 122 143 174 191 208 225 243 262 282 309 326 344 363 383 401 4.66 4.59 4.56 4.47 4.53 4.52 4.57 4.55 4.51 4.33 4.54 4.50 4.51 4.43 4.35 4.44 4.42 4.41 4.35 4.36 4.42 4.41 4.43 4.32 4.41 4.38 3.38 4.34 4.31 5.06 4.96 4.93 4.86 5.54 5.75 5.56 5.7 5.47 5.61 5.36 5.51 5.56 5.54 5.55 5.45 1,821x1,430x3,398 2,113x1,350x4,361 2,323x2,135x4,426 2,150 2,160 2,179 2,224 3,909 3,927 3,945 3,971 3,996 4,080 4,092 6,079 6,097 6,136 6,174 6,192 6,210 2,380 2,396 2,410 2,457 4,217 4,228 4,243 4,262 4,288 4,369 4,386 6,628 6,646 6,670 6,699 6,717 6,735 Single pass shell and tube 193 183 172 271 263 256 248 241 233 472 504 489 472 37
400 394 460
50
460 460 538
550 538 630
54
650 640 757
62
700 705 832
55
44
850 844 993
58
53
66
51
62
56
47
58
62
66
C18 1,510 1,790
353 420 4.28 4.26 5.27 6,228 6,761
71
Single pass shell and tube 19.33 22.92 26.80 31.44 37.31 41.14 45.53 49.21 53.03 57.52 60.39 67.32 70.33 74.34 78.55 82.08 85.52 89.01 26
28
93.7
96.6
30 96.7
26 96.9
25 97.3
97.8
28 98.9
99.8
100.4 100.8 101.2
103.0
75.2
76.2
78.2
77.8
78.2
78.7
79.8
80.7
80.4
80.8
81.2
83.0
Semi-hermetic single screw compressor -8~15 20~55 R-134a Electronic expansion valve 2 104 100 156
155
154
°CDB °CDB
1 kg mm inch Hz / V
800 782 919
54
52
51
50
108
106 168.3
26
23
5 3~ / 50 / 400
60
24
25
24
3 153 219.1
23
152
151
150
EWWD-I-XS
High efficiency Standard sound
Heating only & Cooling only Capacity class Cooling capacity Heating capacity Capacity control Power input EER COP ESEER Dimensions Weight
Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Water volume evaporator Nominal water Cooling Heat exchanger pressure drop Water heat Type exchanger Water flow rate Nom. condenser Water flow Nom. rate 2 Nominal water Cooling pressure drop Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Control Circuits Quantity Refrigerant circuit Charge Piping Evaporator water inlet/outlet connections Condenser water inlet/outlet Power supply Phase / Frequency / Voltage
kW kW % kW kW
mm kg kg l kPa
l/s l/min kPa dBA dBA
360 362 410.9
71 85.9 5.10 4.78 5.34 2,594 2,998
440 433 493
600 573 660
25 85.4 100 103 121 5.07 5.06 4.79 4.77 5.27 5.22 1,883x1,430x4,081 2,667 2,704 3,078 3,116
326
317
64
48
20.69
500 506 577
121 143 4.75 4.62 5.11
308 54
24.77
750 720 823
28.95
33.16
156 189 5.10 4.80 6.31
48
48
47 96.6
51 96.7
75.20
76.2
78.2
C10 976 1,126
47
C11 1,038 1,203
C12 1,134 1,313
219 263
240 285 4.73
4.57 6.05
504
50
72
46
52
23.31
28.07
27.10
32.82
28
28.07
33
32.82
24.75
96.9
97.3
97.8
98.9
99.8
77.8
78.2
78.7
79.8
80.7
2 172 219.1
170
48
47
50
65
Semi-hermetic single screw compressor -8~15 20~55 R-134a Electronic expansion valve 1 90
87
85
180
177
168.3 5 3~ / 50 / 400
61
174
4.61 5.67 5,132 5,741
24.98
66
째CDB 째CDB
kg mm inch Hz / V
950 933 1,069
170 206 5.08 4.81 6.01
Single pass shell and tube 20.58 20.44 24.75 20.58
93.7
850 866 990
12.5 185 199 223 240 5.05 4.9 4.79 4.69 6.14 5.9 2,245x1,350x4,769 4,964 4,997 5,049 5,073 5,097 5,582 5,615 5,671 5,695 5,729 Single pass shell and tube 539 528 141 172 5.09 4.78 6.13
68
-
800 795 908 Stepless
EWWD-H-XS
Water cooled chiller, high efficiency, standard sound EWWD-H-
MicroTech III
›› ›› ›› ›› ››
Cooling range: 369-1,215 kW Condenser leaving water temperatures (CLWT) up to 65°C (optional) Heat pump version available Flooded type heat exchangers MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications
High efficiency Standard sound
Heating only & Cooling only Capacity class Cooling capacity Heating capacity Capacity control Power input EER ESEER COP Dimensions Weight
Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom.
Unit
HeightxWidthxDepth
Unit Operation weight Water heat Type exchanger Water volume evaporator Nominal water pressure drop Cooling Heat exchanger Water heat Type exchanger Water flow rate Nom. condenser Nominal water pressure drop Cooling Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping Evaporator water inlet/outlet connections Condenser water inlet/outlet Power supply Phase/Frequency/Voltage
kW kW % kW kW
mm
370 369 419
450 445 505
62.8 84.5 5.88 6.44 4.96
75.4 101 5.90 6.47 4.98
530 521 589
610 608 687
2,121x1,353x3,341
87.0 101 117 136 5.99 6.02 6.56 6.57 5.03 5.06 2,121x1,353 2,048x1,384 x3,419 x3,417 3,603 3,781 3,870 4,163
3,089 3,250
3,370 3,588
l kPa
78 48
107 40
134 38
160 42
l/s kPa dBA dBA
20.63 35 96.7 78.0
24.86 30 97.7 79.0
29.05 32 98.7
33.87 28 99.1
210
190
180
80.0
°CDB °CDB
mm inch Hz/V
830 827 924 Stepless
930 932 1,036
980 978 1,093
125 159 5.98 7.16 5.28
138 175 5.99 7.23 5.27
151 192 6.17 7.32 5.40
12.5 163 206 6.00 7.37 5.30
25
kg kg
kg
750 748 837
168.3 6
62
210
2,048x1,689x3,609
C10 1,050 1,173
C11 1,133 1,265
C12 1,215 1,356
174 221
188 238
201 255 6.04 7.42 5.31
6.03 7.40 5.31
2,048x1,711x3,609
5,289 5,375 5,654 5,694 5,835 6,174 Flooded shell and tube 172 201 261 48 40 38 Flooded Shell & Tube 41.71 46.11 51.74 34 30 37 100.2 100.7 101.2 81.0 81.5 82.0 Semi-hermetic single screw compressor -8~15 18~65 R-134a 220 250 1 219.1 8 3~/50/400
7.43 5.32 2,161x1,711x3,509
5,707 6,262 272
6,066 6,709
6,105 6,773
6,156 6,859
295
310 37.0
327 40
63.12
67.65 35
35.0 54.52 35.0 101.7 82.5
300
58.48 33.0 102.2 83.0
102.7 83.5
330
EWWQ-B-SS
Water cooled chiller, standard efficiency, standard sound EWWQ-B-
MicroTech III
›› ›› ›› ›› ›› ›› ›› ›› ››
All models are PED pressure vessel approved 1 or 2 stepless single-screw compressors 1 or 2 truly independent refrigerant circuits Shell and tube heat exchanger Optimised for use with R-410A Standard electronic expansion valve Compact design Partial heat recovery available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications
Standard efficiency Standard sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight Water heat exchanger evaporator Water heat exchanger condenser Sound power level Sound pressure level Compressor Operation range Refrigerant
Refrigerant circuit Refrigerant circuit 2 Piping connections Power supply
Nom. Method Minimum capacity Cooling Nom.
Unit
HeightxWidthxDepth
Unit Operation weight Type Water volume Nominal water pressure drop Cooling Heat exchanger Type Water flow rate Nom. Nominal water pressure drop Cooling Nominal water pressure drop 2 Cooling Cooling Nom. Cooling Nom. Type Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Type Control Circuits Quantity Charge Charge Evaporator water inlet/outlet Condenser water inlet/outlet Phase/Frequency/Voltage
kW % kW
mm kg kg
380 380
460 464
560 562
640 637
800 796
25 85.6 104 128 144 166 172 4.44 4.46 4.40 4.41 4.37 4.64 5.16 5.21 5.22 4.95 5.64 1,849x1,140 2,001x1,276 1,848x1,314 2,158x1,350 x3,535 x5,020 x3,373 x3,454 1,933 1,967 2,283 2,332 2,407 3,921 2,135 2,169 2,543 2,628 2,777 4,422
l kPa
124 47
118 63
176 43
l/s kPa kPa dBA dBA
22.2 58
27.2 62
32.9 37.3 66 63 102.3 83.9
100.2 101.2 82.2 83.0
170 46
°CDB °CDB
1 kg kg mm inch Hz/V
730 727
80
90 -
152.4 5
6
860 862
870 872
960 C10 960 1,007 Stepless
C11 1,055
C12 1,185
C13 1,255
C14 1,325
12.5 190 209 240 232 256 274 290 4.59 4.60 4.19 4.55 4.62 4.59 4.56 5.63 5.59 4.76 5.6 5.61 5.62 5.55 2,158x1,350 1,848x1,314 2,378x1,350 2,455x1,350x5,070 x5,020 x2,001 x4,894 3,949 3,988 2,457 4,344 4,529 4,536 4,607 4,463 4,496 2,812 4,780 5,186 5,200 5,280 Shell and tube 274 344 266 344 325 251 325 538 53 52 48 62 57 55 67 43 48 53 Shell and tube 42.7 23.1 50.9 23.4 27.9 59.6 27.6 34.3 33.4 38.4 15 62 19 62 65 25 65 70 67 62 65 67 70 67 101.5 104.7 102.3 104.7 105.1 103.2 104.7 105.2 106.5 83.2 84 84.9 85.2 85 85.6 86 86.5 86.9 Semi-hermetic single screw compressor -4~10 25~45 R-410A 2 1 2 80 90 85 100 95 100 80 90 85 100 95 100 203.2 5 3~/50/400
64
202 4.26 4.83 1,848x1,314 x2,001 2,427 2,795
C15 1,460
C17 1,748
C19 1,888
C20 2,050
333 401 432 466 4.38 4.36 4.37 4.40 5.18 5.06 5.11 5.07 2,495x1,350 2,495x1,350 x4,892 x4,865 4,988 5,053 5,204 5,289 5,602 5,670 5,881 5,970 505 58
495 86
539 95
527 119
42.6
51 16
50.8
59.8 14
16 14 105.8 106.6 107.1 107.5 86.2 87.0 87.5 87.9
130 130
EWWQ-B-XS
Water cooled chiller, high efficiency, standard sound EWWQ-B-
MicroTech III
›› ›› ›› ›› ›› ›› ›› ›› ›› ››
High efficiency All models are PED pressure vessel approved 1 or 2 stepless single-screw compressors 1 or 2 truly independent refrigerant circuits Shell and tube heat exchanger Optimised for use with R-410A Standard electronic expansion valve Compact design Partial heat recovery available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications
High efficiency Standard sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight Water heat exchanger evaporator Water heat exchanger condenser Sound power level Sound pressure level Compressor Operation range Refrigerant
Refrigerant circuit Refrigerant circuit 2 Piping connections Power supply
Nom. Method Minimum capacity Cooling Nom.
Unit
HeightxWidthxDepth
Unit Operation weight Type Water volume Nominal water pressure drop Cooling Heat exchanger Type Water flow rate Nom. Nominal water pressure drop Cooling Nominal water pressure drop 2 Cooling Cooling Nom. Cooling Nom. Type Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Type Control Circuits Quantity Charge Charge Evaporator water inlet/outlet Condenser water inlet/outlet Phase/Frequency/Voltage
kW % kW
mm kg kg l kPa l/s kPa kPa dBA dBA °CDB °CDB
kg kg mm inch Hz/V
420 422
520 516
640 639
730 725
800 801
970 973
25
C10 1,037
C12 C13 1,158 1,270 Stepless
C14 1,369
C15 1,449
C16 1,573
C17 1,733
C19 1,863
C20 2,020
C21 2,152
25 12.5 227 228 252 269 286 315 349 382 417 451 4.91 5.07 5.04 5.08 5.07 4.99 4.96 4.87 4.84 4.77 5.54 6.13 6.28 6.23 5.92 6 5.73 5.78 5.64 2,495x1,350 2,003x1,446 2,454x1,350x5,219 2,495x1,350x4,829 x4,865 x3,919 2,457 4,831 4,873 4,919 4,969 5,117 5,388 5,408 5,414 3,086 5,479 5,512 5,546 5,606 5,794 5,843 6,110 6,118 6,124 Shell and tube 220 213 200 334 325 538 587 538 575 563 551 495 484 535 527 57 70 73 65 58 55 70 65 56 68 76 71 91 93 115 129 Shell and tube 24.2 29.5 36.5 41.4 45.8 55.7 29.5 64.2 29.6 36.3 36.7 41.2 44.9 44.6 53.3 53.2 61.9 50 40 41 46 60 64 39 84 35 48 49 46 43 60 52 78 39 48 46 43 62 60 79 78 100.9 101.7 102.6 102.7 102.0 102.9 105.2 103.8 105.6 106.1 106.5 105.8 106.2 106.6 107.1 107.5 82.2 83.0 83.9 83.2 84.0 85.6 84.9 86.0 86.5 86.9 86.2 86.6 87.0 87.5 87.9 Semi-hermetic single screw compressor -4~10 25~45 R-410A 1 2 1 2 95 110 130 120 130 120 130 120 120 130 152.2 203.2 254 203.2 254 203.2 254 8 6 5 6 5 6 8 3~/50/400 84.9 4.97 5.86
102 5.03 5.88
126 5.09 5.97
143 5.07 5.95 2,001x1,268 2,001x1,276x3,863 x3,878 2,322 2,403 2,464 2,738 2,594 2,685 2,745 3,158
159 193 5.05 5.89 5.66 2,003x1,314 2,003x1,446 x3,878 x3,919 2,407 2,427 2,815 3,056
65
12.5 205 5.06 6.18 2,454x1,350 x5,219 4,775 5,431
C11 1,116
EWWD-FZXS
Water cooled chiller with centrifugal compressor high efficiency, standard sound EWWD640-C10FZXS
pCO2
›› ›› ›› ›› ››
Oil free compressor technology with magentic bearing Wide capacity range from 114 to 1,048 kW An inverter driven compressor allows the capacity to be adjusted precisely to match variations in room and outside temperatures Top seasonal efficiency (ESEER up to 9.60) Onboard digital electronics provide smart controls
High efficiency Standard sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight
Min. Max. Method Cooling Cooling
Min. Max.
HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Nominal water Cooling Heat evaporator exchanger pressure drop Water heat Type exchanger Water flow rate Nom. condenser Nominal water Cooling pressure drop Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping Evaporator water inlet/outlet connections Condenser water inlet/outlet Power supply Phase / Frequency / Voltage
kW kW
320 114 317
430 128 429
kW kW
21.6 65.9
27.7 85.7
mm kg kg
5.40 8.60 1,823x1,276x3,254 2,360 2,416 2,520 2,634
kPa
30
31
520 640 172 114 521 635 Variable speed centrifugal compressor 33.1 21.6 104 132 6.00 5.40 9.40 8.80 1,823x1,276x3,419 1,755x1,790x3,441 2,546 3,709 2,812 4,074 Flooded shell and tube (2 passes) 23
860 128 856
C10 172 1,048
27.7 171 5.50 8.60 1,748x1,853x3,289 4,095 4,548
33.1 206 5.90 9.60 1,794x1,904x3,401 4,765 5,330
21
11
49.1
59.9
18
Flooded shell and tube (2 passes) 29.9 36.7
l/s kPa
18.3
24.6
24
25
28
24
25
29
dBA dBA
89.0
90.1
91.2
92.4
93.6
94.6
70.9
72.0
73.0
73.8
75.1
75.9
°CDB °CDB kg
mm mm Hz / V
210
190
168.3
Oil free centrifugal compressor with magnetic bearings 2~15 18~46 R-134a 180 220 Electronic expansion valve 1 219.1
168.3
273 219.1
3~ / 50 / 400
66
300
DWSC / DWDC
Water cooled chiller with centrifugal compressor
›› ›› ›› ››
Single compressor unit up to 4.5MW Dual compressor unit on single circuit up to 9MW Optional variable speed drives (VFD) for superior partload performance Compressor unloading down to 5% for dual compressor units and 10% for single compressor units without hot gas bypass ›› Control flexibility for easy integration into BMS
WIDE CHOICE OF CAPACITIES AND EFFICIENCIES Single compressor ›› DWSC: 300 kW - 4,500 kW - Approximately 1.1 million possible chiller offerings with combination options of motors, impellers, gears and vessels Dual compressor ›› DWDC: 600 kW - 9,000 kW - Approximately 0.75 million possible chiller offerings with combination options of motors, impellers, gears and vessels
VARIABLE FREQUENCY DRIVE OPTION (VFD) ›› Inverter technology greatly improving part load efficiency ›› Reducing annual energy costs HIGH EFFICIENCY ›› COP up to 7 at full load ›› COP up to 12 at partial load (when coupled with inverter VFD) POWER LOSS DAMAGE PROTECTION Power failures do not allow chillers to proceed through their normal shutdown sequence. Poor lubrication at this point can damage the bearings and reduce compressor life. The compressors are equipped with a lubricant reservoir and a Piston piston with a compressed spring that provides pressurized Lubricant reservoir lubricant to the bearings during the coast-down period. Also, the compressors decelerate quickly due to the low inertia. REFRIGERANT STORAGE CAPABILITY The condensers are sized to hold the entire chiller refrigerant charge and are provided with the necessary valves to isolate this charge. This feature eliminates the need for separate storage vessels in most applications. 68
UNMATCHED UNLOADING Unloading to 10% of full load for a DWSC single compressor chiller and 5% for a DWDC dual compressor unit, without using inefficient hot gas bypass. This unloading capability provides improved stability of the chilled water temperature and less harmful cycling of compressors. Movable discharge diffuser increases stability and reduces vibrations.
Moveable diffuser closing off impeller discharge area
LOW OPERATIONAL SOUND LEVEL Liquid Injection A small amount of liquid refrigerant is taken from the condenser and injected into the compressor discharge area. The liquid droplets absorb sound energy and reduce the compressor's overall operational sound level. The droplets evaporate and reduce discharge superheat. Quieter as chiller unloads Daikin’s design results in a reduction in sound levels at lower loads, where most chillers spend most of their operating hours.
ONE DWDC DUAL COMPRESSOR CHILLER VERSUS TWO SINGLE COMPRESSOR CHILLERS ›› Lower equipment costs than two separate chillers ›› Lower installation cost than two separate chillers ›› Lower annual operating cost than either one large or two small chillers ›› Less equipment room space required than for two separate chillers (smaller footprint) ›› Capacity reduction to 5% of design value ›› Standby redundancy for most of the cooling season options of motors, impellers, gears and vessels
EXCELLENT PART LOAD EFFICIENCY When one compressor is running, it is able to utilize the heat transfer area of the entire chiller, twice the amount found on a single compressor chiller. This huge amount of surface provides exceptional part load efficiency. The addition of VFDs to the dual compressor chiller produces a very high ARI certified Integrated Part Load Value (IPLV). PARTIAL LOADS EFFICIENCY FOR 2,000 kW CENTRIFUGAL UNIT 10.0 9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0
7.0
D
9.7
7.4
D
D
10.0
DWSC: single compressor DWDC: double compressor VFD: compressor inverter Specific selections can vary up or down from this example.
D
69
1. Temperature sensor 2. Filter 3. Shut-off valve 4. Pump 5. Pressure port 6. Flow switch 7. Air purge 8. Pressure gauge 9. Balancing valve 10. Drain valve 11. Charging valve 12. Safety valve
CONDENSERLESS 1
To condenser
3
2
5
4
5
Expansion vessel
Chillers
12
Evaporator
Gas
7
Buffer tank
To fan coil units
Liquid
1
6
5
8
11
9
70
10
Daikin offers you flexible condenserless chillers with remote condenser, which can be used to satisfy applications with special requirements in the field of available space, sound level or extreme operating conditions. In these exceptional cases, remote condenser solutions can be preferred over standard air-cooled or water-cooled solutions.
Condenserless chillers NEW
EWLP-KBW1N EWLD-J-SS EWLD-G-SS EWLD-I-SS
72 73 74 75
71
EWLP-KBW1N
Condenserless chiller EWLP012-030KBW1N
μC² SE
›› ›› ›› ›› ›› ›› ›› ›› ›› ››
Daikin scroll compressor Optimised for use with R-407C Low operating sound level Low energy consumption Compact dimensions and low refrigerant volume Easy installation and maintenance Stainless steel plate heat exchanger Compatible with hydraulic module Main switch, pressure ports, flow switch, filter, shutoff valves and air purge are standard included µC² SE DDC controller
Cooling only Capacity class Cooling capacity Power input EER Dimensions Weight Water heat exchanger evaporator
Nom. Cooling
Nom.
HeightxWidthxDepth Unit Unit Minimum water volume in the system Water flow rate Min. Nom. Max. Model Quantity Type Sound power level Cooling Nom. Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Control Circuits Quantity Piping Evaporator water inlet/outlet connections Evaporator water drain Power supply Phase / Frequency / Voltage
kW kW
012 12.1 4.2 2.88
020 20.0 6.6 3.03
mm kg l
108
l/min l/min l/min
dBA
026 26.8 8.5 3.15
030 31.2 10.1 3.09
040 40.0 13.4 2.99
141
147
151
62
103
134
155
17 35 69
29 57 115
38 77 153
205
268
311
45 57 89 115 179 229 1 Brazed plate 71 Hermetically sealed scroll compressor -10~20 25~60 R-407C Thermostatic expansion valve
77 154 307
89 179 358
600x600x600
64
°CDB °CDB
mm
065 62.4 20.3 3.07
252
055 53.7 17.8 3.02 600x600x1,200 265
1 FBSP 25
72
74
2 FBSP 40 Field installation 3N~ / 50 / 400
Hz / V
67
274
EWLD-J-SS
Condenserless chiller standard efficiency, standard sound EWLD-J-
MicroTech III
›› ›› ›› ›› ›› ››
Compact design to allow easy indoor installation or retrofit operations Steples single screw compressor High efficiency at full and partial load Chilled water temperatures down to -10°C on standard unit Optimised for use with R-134a MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications
Standard efficiency Standard sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER Dimensions Weight Water heat exchanger evaporator Sound power level Sound pressure level Compressor Operation range Refrigerant Piping connections Power supply
Nom. Method/Minimum capacity Cooling Nom.
kW % kW
HeightxWidthxDepth Unit Unit Operation weight Nominal water pressure drop Cooling Total Type Cooling Nom. Cooling Nom. Type Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Type Circuits Quantity Evaporator water inlet/outlet Phase/Frequency/Voltage
mm kg kg kPa dBA dBA
110 110
130 128
30.9 3.55
38.0 3.36
1,124 1,138 14
1,141 1,159 12
145 143
165 195 164 192 Stepless/25 43.3 49.8 55.3 3.31 3.30 3.47 1,020x913x2,684 1,237 1,263 1,305 1,253 1,281 1,327 36 34 32 88.6 71.4
°CDB °CDB 1 inch Hz/V
73
235 237
265 265
290 286
310 307
330 328
360 390 430 356 383 429 Stepless/12.5 65.2 74.5 86.5 93.0 99.5 105 111 121 3.63 3.56 3.31 3.30 3.39 3.47 3.56 2,000x913x2,684 1,489 2,474 2,500 2,526 2,568 2,611 2,795 1,518 2,505 2,533 2,562 2,608 2,655 2,845 25 31 36 34 32 Brazed plate, one per circuit 87.2 92.4 91.8 70.0 74.4 73.8 Semi-hermetic single screw compressor -10~15 25~60 R-134a 2 3 3~/50/400
470 474
500 502
530 530
130 3.63
140 3.59
149 3.56
2,979 3,036 25
31 91.0 73.0
EWLD-G-SS
Condenserless chiller standard efficiency, standard sound EWLD-G-SS
MicroTech III
›› ›› ›› ›› ›› ›› ›› ›› ››
Cooling range: 161-526kW EER range: 3.48 to 3.70 Stepless single-screw compressor Optimised for use with R-134a 1 or 2 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side for easy oil circulation and return All models are PED pressure vessel approved MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications
Standard efficiency Standard sound
Cooling only Capacity class Cooling capacity Capacity steps Power input EER Dimensions Weight
Nom. Cooling
Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Minimum water volume in the exchanger system evaporator Water flow rate Min. Nom. Max. Nominal water Cooling Heat exchanger pressure drop Model Quantity Type Type Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage
kW % kW mm kg kg l l/min l/min l/min kPa
160 161
190 240 189 244 stepless 25 - 100 54.3 65.9 3.48 3.70 1,860x1,000x3,700
45.4 3.54 1,280 1,337
280 270
320 316
74.6 3.62
90.6 3.48
1,398 1,516
360 352
380 420 381 428 stepless 12.5 - 100 99.7 108.6 120 3.53 3.51 3.57 1,942x1,100x4,400 2,446 2,501 2,560
2,442
480 476
550 526
131.5 3.62
148 3.55 2,506
2,670
1,151
1,354
1,749
1,938
1,130
1,262
1,365
1,535
1,704
1,884
230.20 460.39 649.15
270.90 541.81 763.95
349.74 699.47 986.26
387.58 775.16 1,092.97
452.22 904.44 1,275.27
504.83 1,009.65 1,423.61
546.25 1,092.50 1,540.42
613.90 1,227.81 1,731.21
681.84 1,363.69 1,922.80
753.80 1,507.60 2,125.71
48
69
43
53
64
63
72
54
68
1 EV19270055 dBA dBA
EV27270066
EV27270077 EV27270088 Shell and tube - direct expansion
88
EV32270088
EV32270099
90.5
69.7
71.7 Semi-hermetic single screw compressor -8~15 25~60 R-134a
°CDB °CDB kg
5
10 Electronic expansion valve
1 mm Hz / V
2
88.9
114.3 3~ / 50 / 400
74
139.7
EWLD-I-SS
Condenserless chiller standard efficiency, standard sound EWLD-I-SS
MicroTech III
›› ›› ›› ›› ›› ›› ›› ››
Cooling range: 328–1,422kW EER range: 3.51 to 3.91 Stepless single-screw compressor Optimised for use with R-134a Standard electronic expansion valve DX shell and tube evaporator – one pass refrigerant side for easy oil circulation and return All models are PED pressure vessel approved MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications
Standard efficiency Standard sound
Cooling only Capacity class Cooling capacity Capacity control Power input EER Dimensions Weight
Nom. Method Minimum capacity Cooling Nom.
HeightxWidthxDepth Unit Unit Operation weight Water heat Water flow rate Nom. exchanger Nominal water Cooling Total evaporator pressure drop Type Sound power level Cooling Nom. Sound pressure Cooling Nom. level Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage
kW % kW mm kg kg l/min kPa
dBA dBA
320 328
400 391
420 428
500 504
25 83.8 100 116 137 3.91 3.9 3.7 3.67 1,899x1,464x3,114 1,861 1,869 1,884 2,054 2,052 2,056 940.2 1,120.8 1,227.0 1,444.8 34
47
600 596
650 657
165 3.61
181 3.63
3,331 3,339 3,602 1,708.8 1,883.4
54
49
39
750 730
800 788
900 950 C10 C11 C12 C13 C14 C15 C16 919 966 1,033 1,078 1,125 1,188 1,267 1,319 1,370 Stepless 12.5 8.3 198 214 231 252 271 279 296 312 329 347 366 386 3.69 3.67 3.65 3.56 3.59 3.64 3.60 3.61 3.65 3.60 3.55 2,325x1,464x4,391 2,415x2,135x4,426 3,347 3,356 3,364 3,412 5,146 5,167 5,188 5,208 3,603 3,604 3,605 3,645 5,667 5,671 5,677 5,680 2,092.8 2,259.0 2,436.6 2,634.6 2,769.0 2,961.0 3,090.0 3,225.0 3,405.6 3,631.8 3,781.2 3,927.6 52
850 850
47
45
52
46
49
41
51
55
59
C17 1,422
405 3.51
4,076.4 63
93.7
96.6
96.7
96.9
97.3
97.8
Single pass shell and tube 98.9 99.8 100.4 100.8 101.2 103 100.4 100.8 101.2 103
75.2
76.2
78.2
77.8
78.2
78.7
79.8
80.7
80.4
80.8
Semi-hermetic single screw compressor -8~15 25~60 R-134a 5 Electronic expansion valve 2
°CDB °CDB kg 1 mm
168.3
75
83
80.4
3 219.1
3~ / 50 / 400
Hz / V
81.2
80.8
81.2
83
D.I.C.N.
Daikin Integrated Chiller Network
APPLICABLE SERIES: ›› ››
EWAQ080-260DAYN (R-410A) EWYQ080-250DAYN (R-410A)
Daikin chillers can be equipped with DICN which allows the simultaneous operation of up to 4 chillers as if they were a single unit, in order to deliver the required cooling capacity. This results in precise and efficient capacity control and is also useful for back up purposes, ensuring that the necessary amount of cooling is available and guaranteeing reliable operation of the chiller plant. This function enables a Daikin chiller plant to be operated via a single controller. Please note that DICN is only possible within the same series.
76
EHMC/EKBT
Hydraulic Module / Buffer Tank EHMC10-15-30A10
mH2O 55 50 45
›› ›› ›› ›› ›› ››
3 models available 100 l tank for all sizes freeze up protection high static pump (option) standard drain kit (for indoor use) standard dual pressure ports (before & behind the pump)
40 35
LEGENDS Pump characteristics 1. EHMC30A80 2. EHMC10A80 & EHMC15A80 3. EHMC30A10 4. EHMC10A10 & EHMC15A10 Hydraulic module + filter pressures losses 5. EHMC15/30A10 & EHMC15/30A80 6. EHMC10A10 & EHMC10A80
30 25 20 15 10 5 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 ( l/min)
Water flow
HYDRAULIC MODULE 10
EHMC-AV Nominal flow Nominal External static pressure Nominal input Dimensions (HxWxD) Machine weight Sound power Sound pressure Power supply Operation range Water side Air side Piping connections Water inlet/outlet Drain connection
10 l/min mH2O W mm kg dBA dBA V1 °C °CDB inch inch
15 80
10
62 17 630
10
88 34 1,050
15 650
101
102
1,284x635x688 99
30 80 27 1,070
10 1,070
104
105
1,284x635x688
63 52
27 2,090 1,284x635x688
63 52 1~/230V/50Hz -10°C ~ 55°C -10°C ~ 43°C 2" BSPF 1/2"
1" BSPF
80 187
111 63 52
2-1/2" BSPF
BUFFER TANK MODEL
Description
Volume
Dimensions
Unit weight
EKBT
Buffer tank with cabinet
EKBT500C
Buffer tank with cabinet
200l
1,284x637x754
86.5
500l
1,200x1,200x1,950
EKBTC10C
160
Buffer tank with cabinet
1,000l
1,200x1,450x1,950
185
EKBT500N
Buffer tank
500l
710x1,670
70
EKBTC10N
Buffer tank
1,000l
860x2,020
100
77
Dry Coolers & Condensers
Duct type with centrifugal fan
V Shape type with axial fan
Horizontal or vertical type with axial fan
›› ›› ›› ›› ››
Single coil, both for vertical and horizontal installation, or double coil (V shape) For air conditioning and for industrial process cooling Extreme low noise and energy saving models available Factory engineered and mounted controls Capacities from 3 up to more than 2,400 kW
Cooling Towers
Radial fan type
›› ›› ›› ›› ›› ›› ›› ››
Axial fan type
Open circuit type Closed circuit type Evaporative condenser type Radial or axial fans Galvanized steel, Stainles steel or Fiberglass For air conditioning and for industrial process cooling Low noise and energy saving models available Capacities from 70 up to more than 9,200 kW
78
Ventilation Fan coil units Casette units FWC-BT/BF FWF-BT/BF FWC-AT/AF FWF-CT
80 81 81 82 83 84
Concealed ceiling units FWB-JT/JF FWB-BT
85 85 86
Wall mounted units FWT-BT
87 87
Flexi type units FWL-DT/DF FWM-DT/DF FWD-AT/AF
88 88 89 90
Floor standing units FWV-DT/DF
91 91
Air Coolers
92
Heat Reclaim Ventilation VAM-FA
93 93
Rooftops UATYQ-CY1 UATYP-AY1
94 94 95
Air handling units
96
PLUG and PLAY VRV速 connection AHU
100
For more information on Options & Accessories, please refer to page 107 of this catalogue. 79
Portfolio Fan coil units
FWV-DT/DF
FWD-AT/AF
FWM-DT/DF
FWL-DT/DF
FWT-BT
FWB-BT
FWB-JT/JF
FWF-CT
FWC-AT/AF
FWF-BT/BF
FWC-BT/BF
Reference 2-pipe
4-pipe
2-pipe
4-pipe
2-pipe
4-pipe
2-pipe
2-pipe
4-pipe
2-pipe
4-pipe
2-pipe
2-pipe
4-pipe
2-pipe
4-pipe
2-pipe
4-pipe
2-pipe
4-pipe
Page 1
2
3
4
5
cooling heating cooling
6
06
07
06
08
09
06
07
07
08
09
06
cooling
cooling
02
03
04
10
08
heating
02 02
03
04
cooling
0304
07
08
0203
08
10
11
12
08
02
02
06
06
heating
09
10 11 07 08
09
10 11
07
08
10 07
06 05
06
07
02 03
04
08
08 09
10 10 05
06
07
08
09
10
86 02 03 04
05
06
07
02 03 04 02 03
08
09
10
05 06 07
04
05
08 09 10
06
87 02
01
02
03 04
03
05
06
04 06
01 02
08
03
04
06
10 08
10
88 01 02
03
01 02 01
04 06 03
02
08 04
03
06
08
04 06
01 02
10
08
03
04
06
10
10 08
10
89 01 02
03
01 02
0406
08
03
10
04 06
08
04
06
08
04
10 10
06
12 08
16 12
10
18 16
18
90 04
06 04
cooling
cooling
08
03 04
heating
heating
07
06
03 04
cooling
cooling
04
04
030405
02
heating
heating
03
03 04 05 02
cooling
cooling
04 05 06
85
heating
heating
03
03 04 02
cooling
cooling
11 12
84
heating
heating
10
04 05 06 02
02 03 04
heating
22kW
09
07
83
cooling
cooling
20
05
07
02
cooling
18
05
heating
heating
16
05
02 03 04
cooling heating
12
09
heating
cooling
11
05
cooling
cooling
9
82
heating
heating
8
81
heating
heating
7
01
02 01
03 02
08
10
06
04 06 04
06
10 08
10
91 01
02 01 02
03
04 06 03
08 0406
80
10 08
10
16 12
10
08
03
12 08
18 16 18
FWC-BT/BF
Round flow cassette
FWC-BT/BF
›› ›› ›› ›› ›› ››
BRC315D7
BRC7E532F
360° air discharge ensures uniform air flow and temperature distribution Modern style decoration panel in white Possibility to shut 1 or 2 flaps for easy installation in corners Fresh air intake for healthy living Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling Standard drain pump with 850mm lift
Indoor units Cooling capacity
2-PIPE
Total capacity Sensible capacity Heating capacity 2-Pipe 4-Pipe Power input High Dimensions Unit Weight Unit Water pressure Cooling drop Heating Fan Type Air flow rate Sound power level High Sound pressure level High Piping Water connections Power supply
High High High High HeightxWidthxDepth
High
Inlet Outlet Drain OD Phase/Frequency/Voltage
kW kW kW kW W mm kg kPa kPa m³/h dBA dBA inch inch mm Hz/V
FWC06BT 5.0 3.4 6.3
FWC07BT 5.6 4.0 7.1
4-PIPE FWC08BT 6.3 4.5 8.3
FWC09BT 7.2 5.3 9.5
40
46
58
76
FWC06BF 4.9 3.4
FWC07BF 5.6 3.9
6.2 41
6.8 47
1,062 36 24
19 19
7.8 59
8.8 77
25 38
32 47
288x840x840 29 26 26
Turbo fan 1,236 1,518 39 44 28 32 3/4” BSP (female thread) 3/4” BSP (female thread) VP25 (External dia. 32, Internal dia. 25) 1~/50/220-240
81
FWC09BF 7.2 5.2
-
288x840x840 26 15 15
FWC08BF 6.3 4.4
34 34
15 24
1,776 49 37
1,032 36 24
19 30
Turbo fan 1,200 1,476 39 44 28 32 3/4” BSP (female thread) 3/4” BSP (female thread) VP25 (External dia. 32, Internal dia. 25) 1~/50/220-240
1,746 49 37
FWF-BT/BF
4-way blow ceiling mounted cassette
FWF-BT/BF
›› ›› ›› ›› ›› ››
BRC315D7
BRC7E532F
Modern style decoration panel in white Compact casing (570mm in width and depth) enables unit to fit flush into ceilings and match standard architectural modules, without cutting ceiling tiles Comfortable horizontal auto swing ensures draughtfree operation and prevents ceiling soiling Possibility to shut 1 or 2 flaps for easy installation in corners Fresh air intake for healthy living Standard drain pump with 750mm lift
Indoor units Cooling capacity
2-PIPE
Total capacity Sensible capacity Heating capacity 2-Pipe 4-Pipe Power input High Dimensions Unit Weight Unit Water pressure Cooling drop Heating Fan Type Air flow rate Sound power level High Sound pressure level High Piping Water connections Power supply
High High High High HeightxWidthxDepth
kW kW kW kW W mm kg kPa kPa
FWF02BT 1.7 1.3 2.6
FWF03BT 2.8 1.7 3.4
4-PIPE FWF04BT 3.3 2.1 4.1
FWF05BT 4.0 2.7 5.3
67
70
19 19
Inlet Outlet Drain OD Phase/Frequency/Voltage
m³/h dBA dBA inch inch mm Hz/V
660 44 33 3/4” BSP (female thread) 3/4” BSP (female thread) VP20 (External dia. 26, Internal dia.20) 1~/50/220-440
82
FWF05BF 3.5 2.3
89
3.9 74
4.8 93
42 42
19 6 12
20 21 9
33 13
876 49 39
468 40 27
3.3 62 285x575x575
31 31
468 40 27
FWF04BF 2.8 1.7 -
Turbo fan High
FWF03BF 2.3 1.3
3.1 67
285x575x575 19 6 6
FWF02BF 1.7
13 6
Turbo fan 438 618 42 46 29 35 3/4” BSP (female thread) 3/4” BSP (female thread) VP20 (External dia. 26, Internal dia.20) 1~/50/220-440
822 51 41
FWC-AT/AF
4-way blow ceiling mounted cassette
FWC-AT/AF
›› ›› ›› ›› ›› ›› ›› ›› ›› ››
MERCA
SRC-COA/HPA
WRC-COB/HPB
Wide operating range Easy installation and maintenance Flexibility (2-pipe or 4-pipe) 3-speed fan motor Double-intake centrifugal fans Air suction from underneath High power air flow Removable washable air filter (self-extinguishing class 1) Built-in high pressure drain pump with 700mm lift Infrared remote control as standard with decoration panel kit
Indoor units Cooling capacity
Total capacity High Sensible capacity High Heating capacity 2-Pipe High 4-Pipe High Power input High Current input High HeightxWidthxDepth Dimensions Unit Weight Unit Operation weight Heat exchanger Water volume Water flow Cooling Heating Water pressure Cooling drop Heating Fan Type Air flow rate High Sound power level High Sound pressure level High Piping connections Std. heat exchanger Drain OD Power supply Phase/Frequency/Voltage
kW kW kW kW W A mm kg kg l l/h l/h kPa kPa m³/h dBA dBA inch mm Hz/V
FWC07AT 6.63 4.90 8.40 127 0.52 31.0 34.0 1,140 1,140 24.8 21.4 1,310 52 42
2-PIPE FWC10AT FWC11AT 8.80 9.95 6.40 7.10 11.00 12.00 151 164 192 0.64 0.68 0.79 335x820x821 32.0 35.0 38.0 35.0 38.0 41.0 2.69 1,290 1,514 1,711 1,290 1,514 1,711 30.8 41.6 52.2 26.8 35.3 45.2 Direct drive turbo fan 1,380 1,560 1,740 55 60 61 45 49 51 3/4 19.05 1~/50/220-240
FWC08AT 7.50 5.40 9.50
83
FWC12AT 10.80 7.70 12.90
FWC02AF 3.81 3.40
253 1.06
10.55 122 0.53
40.0 43.0
31.0 34.0
1,858 1,858 69.3 64.1
655 907 3.56 4.8
1,840 64 53
1,310 52 42
4-PIPE FWC04AF FWC05AF 4.63 5.01 4.07 4.40 10.99 12.51 13.48 138 153 184 0.61 0.67 0.80 335x820x821 32.0 35.0 38.0 35.0 38.0 41.0 2.69 681 796 862 945 1,076 1,159 3.78 4.94 5.70 5.5 7.2 8.6 Direct drive turbo fan 1,380 1,560 1,740 55 60 61 45 49 51 3/4 19.05 1~/50/220-240
FWC03AF 3.96 3.52
FWC06AF 5.16 4.54 13.77 232 1.02 40.0 43.0 888 1,184 5.96 8.9 1,840 64 53
FWF-CT
4-way blow ceiling mounted cassette
FWF-CT
›› ›› ›› ›› ›› ›› ›› ›› ›› ››
MERCA
SRC-COA/HPA
WRC-COB/HPB
4 way air discharge and air swing Compact casing (570mm in width and depth) enables unit to fit flush into ceilings and match standard architectural modules, without cutting ceiling tiles Wide operating range Air suction from underneath Easy installation and maintenance Built-in high pressure drain pump with 700mm lift Double-intake centrifugal fans High power air flow 3-speed fan motor Infrared remote control as standard with decoration panel kit
Indoor units Cooling capacity
Total capacity High Sensible capacity High Heating capacity 2-Pipe High 4-Pipe High Power input High Current input High HeightxWidthxDepth Dimensions Unit Weight Unit Operation weight Water pressure Cooling drop Heating Fan Type Air flow rate High Sound power level High Sound pressure level High Piping connections Std. heat exchanger Drain OD Power supply Phase/Frequency/Voltage
kW kW kW kW W A mm kg kg kPa kPa m³/h dBA dBA inch mm Hz/V
2-PIPE FWF03CT 4.10 2.93 4.69 64 0.28 250x570x570
FWF02CT 2.49 1.91 3.52 63 0.27 22 22 19.00 17.00
FWF04CT 4.54 3.37 5.28 79 0.34 23 23
27.00 24.00 Direct drive turbo fan 680 54 45 3/4 19.05 1~/50/220-440
646 52 42
84
29.00 27.00 748 56 48
FWB-JT/JF
Concealed ceiling unit
FWEC1, 2, 3A
FWB02JT/JF
›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ››
Wide operating range Quiet operation via enlarged fan wheels Easy maintenance: filter can be removed from both sides and beneath (maximum filter size is 400mm) Flexibility (2-pipe or 4-pipe) 4-speed fan motor Direct driven centrifugal fans Flexibility via interchangeable water connection side High power air flow Available static pressure of 30 Pa Extended drain pan as standard Standard Filter Insulated with self-extinguishing class 1 heat insulation Electronic room thermostat
Indoor units Cooling capacity Heating capacity Power input Current input Dimensions Weight
Total capacity Sensible capacity 2-Pipe 4-Pipe High High Unit
High High High High
HeightxWidthxDepth
Unit Operation weight Heat exchanger Water volume Water flow Cooling Heating Additional heat exchanger Water pressure Cooling drop Heating Additional heat exchanger Fan Type Air flow rate High Available pressure High Sound power level High Sound pressure level High Piping connections Std. heat exchanger Power supply Phase / Frequency / Voltage
kW kW kW kW W A mm kg kg l l/h l/h l/h kPa kPa kPa m³/h Pa dBA dBA inch Hz / V
2-PIPE 4-PIPE FWB02JT FWB03JT FWB04JT FWB05JT FWB06JT FWB07JT FWB08JT FWB09JT FWB10JT FWB11JT FWB02JF FWB03JF FWB04JF FWB06JF FWB07JF 1.64 2.67 2.99 3.34 4.81 5.31 6.16 7.26 8.49 8.99 1.67 2.67 3.03 4.88 5.33 0.94 1.88 1.95 2.07 3.40 4.15 4.39 5.06 6.37 6.41 0.97 1.83 1.93 3.41 4.01 2.16 3.62 3.97 4.11 6.30 7.47 8.09 9.64 11.57 11.71 2.12 3.69 3.87 6.40 7.52 2.49 3.92 4.43 6.70 8.16 34 53 57 54 86 121 117 134 164 166 34 51 54 84 117 0.15 0.24 0.26 0.25 0.39 0.55 0.53 0.61 0.75 0.15 0.23 0.25 0.38 0.53 251x814 251x984 251x1,314 251x1,664 251x814 251x984 251x1,114 251x1,314 251x1,564 251x1,114x590 251x1,564x590 251x1,924x590 x590 x590 x590 x590 x590 x590 x590 x590 x590 20.0 23.0 28.0 31.0 33.0 44.0 48.0 52.0 50.0 56.0 22.0 27.0 31.0 36.0 48.0 20.7 24.0 29.1 32.5 34.4 45.8 50.4 54.6 52.4 59.1 22.9 28.3 32.5 37.9 50.4 0.69 0.95 1.14 1.52 1.44 1.82 2.42 2.62 2.36 3.14 0.92 1.26 1.52 1.92 2.42 386 549 739 803 1,022 1,109 1,383 1,523 1,764 1,910 386 530 724 986 1,138 386 549 738 802 1,020 1,107 1,336 1,524 1,764 1,911 387 530 725 985 1,139 269 391 493 663 820 10.91 8.34 15.64 11.22 31.31 12.56 7.62 9.83 21.71 16.81 10.95 8.24 15.67 29.95 9.24 8.86 6.76 12.84 9.21 25.87 11.13 6.57 8.60 18.56 14.46 8.94 6.64 12.84 24.16 7.89 10.66 24.73 41.72 81.63 25.31 Direct driven centrifugal fan (forward-curved blades)hot-galvanised steel 262 428 431 428 757 945 950 1,066 1,463 1,341 220 424 437 747 898 30 30 47.5 52 49 50 52 55 55.5 56 47 52 50 52 35.5 40 37 38 40 39.5 43 43.5 44 35 40 38 40 39.5 3/4 3/4 1~ / 50 / 220-240 1~ / 50 / 220-240
85
FWB08JF 6.53 4.91 9.01 9.56 137 0.62 251x1,664 x590 52.0 54.6 2.62 1,296 1,299 924 12.49 9.67 31.33
FWB10JF 8.21 6.28 11.09 11.68 163 0.74 251x1,924 x590 56.0 59.1 3.14 1,660 1,660 1,142 19.38 16.50 50.03
1,112 1,385 55 43
56 44
FWB-BT
Concealed ceiling unit
FWEC1, 2, 3A
FWB04BT
›› ›› ›› ›› ›› ›› ››
Low sound power levels and electrical absorption thanks to plastic impeller, ABS winding staircase and improved electric motor Compact dimensions, can easily be mounted in a narrow ceiling void 3, 4 or 6 stage row cooling coil Drain pan to collect the condensate from: heat exchanger and regulating valves 7-speed electrical motors (with thermal protection on windings) All 7 speeds pre-wired in the factory in the terminal block of the switch box The air filter can easily be removed for cleaning
Indoor units Cooling capacity Heating capacity Power input Current input Dimensions Weight Heat exchanger Additional heat exchanger Water flow
Total capacity High Sensible capacity High 2-Pipe High 4-Pipe* High High High HeightxWidthxDepth Unit Unit Operation weight Water volume Water volume
Cooling Heating Additional heat exchanger Water pressure Cooling drop Heating Additional heat exchanger Fan Type Air flow rate High Available pressure High Sound power level High Sound pressure level High Piping connections Std. heat exchanger Add. heat exchanger Drain OD Power supply Phase / Frequency / Voltage
kW kW kW kW W A mm kg kg l l l/h l/h l/h kPa kPa kPa m³/h Pa dBA dBA inch inch mm Hz / V
FWB02BT 2.61 1.88 5.47
23 24 1.1
FWB03BT FWB04BT 3.14 3.49 2.16 2.34 6.01 6.47 3.14 79 0.36 239x1,039x609 24 26 26 28 1.5 2.2
FWB05BT 5.08 3.6 10.31
31 33 1.6
0.4 448 480 8 7
2-PIPE FWB06BT FWB07BT 5.45 6.47 3.87 4.4 11.39 12.28 5.99 154 0.73 239x1,389x609 33 35 35 38 2.1 3.2
FWB08BT 7.57 5.23 15.05
43 45 2.1
FWB09BT FWB10BT 8.67 10.34 5.96 6.9 16.85 18.78 12.8 294 1.28 239x1,739x609 45 48 48 52 2.8 4.2
0.6
539 527 275 14 10 3
598 567
936 1,111 1,299 999 1,077 1,319 526 11 15 8 14 8 12 7 10 16 5 Centrifugal - forward blades - directly coupled on fan motor 800 65 59 47.5 3/4 3/4 16 1~ / 50 / 230
400 71 56 44.5
*4-pipe = 2-pipe + option additional heat exchanger
86
1.7
873 904
1,488 1,479 1,123 21 15 8 1,200 59 69 57.5 1
1,774 1,647 26 18
FWT-BT
Wall mounted unit
FWT05, 06BT
›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ››
MERCA
SRC-COA/HPA
WRC-COB/HPB
Wide operating range Easy installation and maintenance 3-speed fan motor Double-intake centrifugal fans Excellent air flow and air distribution Flexibility via interchangeable water connection side High power air flow Insulated with self-extinguishing class 1 heat insulation Removable washable air filter (self-extinguishing class 1) Slim and compact aesthetic design Wireless remote control up to 9m distance, availability of a wired or simplified controller LED indicator gives an indication on the (normal or wrong) operation of the unit
Indoor units Cooling capacity
Total capacity High Sensible capacity High Heating capacity 2-Pipe High Power input High Current input High HeightxWidthxDepth Dimensions Unit Weight Unit Operation weight Heat exchanger Water volume Water flow Cooling Heating Water pressure Cooling drop Heating Fan Type Air flow rate High Sound power level High Sound pressure level High Piping connections Std. heat exchanger Drain OD Power supply Phase / Frequency / Voltage
kW kW kW W A mm kg kg l l/h l/h kPa kPa m³/h dBA dBA inch mm Hz / V
FWT02BT 2.34 1.74 3.02 24
2-PIPE FWT04BT 3.22 2.35 4.10 29 0.13
FWT03BT 2.78 2.03 3.75 25 0.11
260x799x198 10 10 0.49 402 402 48.3 42
FWT05BT 4.54 3.65 6.01 66 0.29
260x899x198 12 13 0.57 478 478 64.7 58.6
467
510 53
40
39
554 554 69.3 60.6 Direct drive cross flow fan 586 55 42 1/2
16
304x1,062x222 16 17 0.85 781 781 50.3 50.6
908 908 69.3 70.6
1,070 61 49
1,121 64 50 20
1~ / 50 / 220-240
87
FWT06BT 5.28 4.33 6.74 69 0.30
FWL-DT/DF
Flexi type unit
FWL-DT/DF
›› ›› ›› ›› ›› ›› ›› ››
FWL-DT/DF
FWEC1, 2, 3A
ECFWMB6
Quick fixing system for wall or ceiling mounted installation Pre-assembled 3-way/4-port on/off valves are available Valve packages are insulated, no extra drain pan required Valve packages contain balancing valves and sensor pocket Fast-on connections for electrical options: no tools needed The air filter can easily be removed for cleaning Electric heater: no relay up to 2kW capacity Electric heater: equipped with two overheat cut-out thermostats
Indoor units Cooling capacity
Total capacity High Sensible capacity High Heating capacity 2-Pipe High 4-Pipe High Power input High Current input High HeightxWidthxDepth Dimensions Unit Weight Unit Heat exchanger Water volume Water flow Cooling Heating Water pressure Cooling drop Heating Fan Type Air flow rate High Sound power level High Piping connections Std. heat exchanger Power supply Phase/Frequency/Voltage
kW kW kW kW W A mm kg l l/h l/h kPa kPa m³/h dBA inch Hz/V
2-PIPE 4-PIPE FWL01DT FWL02DT FWL03DT FWL04DT FWL06DT FWL08DT FWL10DT FWL01DF FWL02DF FWL03DF FWL04DF FWL06DF FWL08DF FWL10DF 1.54 2.09 2.93 4.33 4.77 6.71 8.02 1.46 1.90 2.87 4.33 4.67 6.64 7.88 1.20 1.51 2.11 3.15 3.65 4.91 5.96 1.14 1.51 2.07 3.15 3.57 4.85 5.85 2.14 2.57 3.81 5.63 6.36 7.83 10.03 1.90 2.10 3.08 5.05 5.30 7.91 9.30 37 53 56 98 137 175 37 53 56 98 137 175 0.17 0.24 0.25 0.44 0.43 0.60 0.76 0.17 0.24 0.25 0.44 0.43 0.60 0.76 564x774x226 564x984x226 564x1,194x226 564x1,404x251 564x774x226 564x984x226 564x1,194x226 564x1,404x251 20 21 27 32 33 44 21 22 28 34 35 46 0.5 0.7 1 1.4 2.1 0.5 0.7 1 1.4 2.1 265 359 504 745 820 1,154 1,343 251 327 494 745 803 1,142 1,355 265 359 504 745 820 1,154 1,343 196 182 286 396 465 694 816 13 11 12 14 12 19 13 11 12 14 12 19 9 11 9 10 9 16 7 8 5 10 8 9 Centrifugal multi-blade, double suction Centrifugal multi-blade, double suction 319 344 442 706 785 1,011 1,393 307 327 431 690 763 998 1,362 45 50 47 52 56 58 64 45 50 47 52 56 58 64 1/2 3/4 1/2 3/4 1~/50/230 1~/50/230
88
FWM-DT/DF
Flexi type unit
FWM-DT/DF
›› ›› ›› ›› ›› ›› ›› ››
FWM-DT/DF
FWEC1, 2, 3A
Quick fixing system for wall or ceiling mounted installation Pre-assembled 3-way/4-port on/off valves are available Valve packages are insulated, no extra drain pan required Valve packages contain balancing valves and sensor pocket Fast-on connections for electrical options: no tools needed The air filter can easily be removed for cleaning Electric heater: no relay up to 2kW capacity Electric heater: equipped with two overheat cut-out thermostats
Indoor units Cooling capacity
Total capacity High Sensible capacity High Heating capacity 2-Pipe High 4-Pipe High Power input High Current input High HeightxWidthxDepth Dimensions Unit Weight Unit Heat exchanger Water volume Water flow Cooling Heating Water pressure Cooling drop Heating Fan Type Air flow rate High Sound power level High Piping connections Std. heat exchanger Drain OD Power supply Phase/Frequency/Voltage
kW kW kW kW W A mm kg l l/h l/h kPa kPa m³/h dBA inch mm Hz/V
2-PIPE 4-PIPE FWM01DT FWM02DT FWM03DT FWM04DT FWM06DT FWM08DT FWM10DT FWM01DF FWM02DF FWM03DF FWM04DF FWM06DF FWM08DF FWM10DF 1.54 2.09 2.93 4.33 4.77 6.71 8.02 1.46 1.90 2.87 4.33 4.67 6.64 7.88 1.20 1.51 2.11 3.15 3.65 4.91 5.96 1.14 1.51 2.07 3.15 3.57 4.85 5.85 2.14 2.57 3.81 5.63 6.36 7.83 10.03 1.90 2.10 3.08 5.05 5.30 7.91 9.30 37 53 56 98 137 175 37 53 56 98 137 175 0.17 0.24 0.25 0.44 0.43 0.60 0.76 0.17 0.24 0.25 0.44 0.43 0.60 0.76 535x584x224 535x794x224 535x1,004x224 535x1,214x249 535x584x224 535x794x224 535x1,004x224 535x1,214x249 14 15 19 23 32 15 16 20 25 34 0.5 0.7 1 1.4 2.1 0.5 0.7 1 1.4 2.1 265 359 504 745 820 1,154 1,343 251 327 494 745 803 1,142 1,355 265 359 504 745 820 1,154 1,343 196 182 286 396 465 694 816 13 11 12 14 12 19 13 11 12 14 12 19 9 11 9 10 9 16 7 8 5 10 8 9 Centrifugal multi-blade, double suction Centrifugal multi-blade, double suction 319 344 442 706 785 1,011 1,393 307 327 431 690 763 998 1,362 45 50 47 52 56 58 64 45 50 47 52 56 58 64 1/2 3/4 1/2 3/4 17 17 1~/50/230 1~/50/230
89
FWD-AT/AF
Flexi type unit
FWD04AT/AF
›› ›› ›› ››
FWEC1,2,3A
FWD04AT/AF
Quick fixing system for wall or ceiling mounted installation Straight duct connector is mounted to discharge side Electronic controller with water probe, available in standard, advanced and advanced plus version The air filter can easily be removed for cleaning
Indoor units Cooling capacity Heating capacity Power input Current input Dimensions Weight Heat exchanger Additional heat exchanger Water flow
Total capacity Sensible capacity 2-Pipe 4-Pipe High High Unit Unit Water volume Water volume
High High High High
HeightxWidthxDepth
Cooling Heating Water pressure Cooling drop Heating Fan Type Air flow rate High Available pressure High Sound power level High Piping connections Std. heat exchanger Drain OD Power supply Phase / Frequency / Voltage
kW kW kW kW W A mm kg l l
2-PIPE 4-PIPE FWD04AT FWD06AT FWD08AT FWD10AT FWD12AT FWD16AT FWD18AT FWD04AF FWD06AF FWD08AF FWD10AF FWD12AF 3.90 6.20 7.80 8.82 11.90 16.40 18.30 3.90 6.20 7.80 8.82 11.90 3.08 4.65 6.52 7.16 9.36 12.80 14.10 3.08 4.65 6.52 7.16 9.36 4.05 7.71 9.43 10.79 14.45 19.81 21.92 4.49 6.62 9.21 15.86 234 349 443 714 1,197 234 349 443 714 0.95 1.58 1.97 3.21 5.37 0.95 1.58 1.97 3.21 280x754x559 280x964x559 280x1,174x559 352x1,174x718 352x1,384x718 280x754x559 280x964x559 280x1,174x559 352x1,174x718 33 41 47 49 65 77 80 35 43 50 52 71 1.06 1.42 1.79 2.38 2.5 4.02 5.03 1.06 1.42 1.79 2.38 2.50 -
l/h l/h kPa kPa
674 674 17 14
m³/h Pa dBA inch mm Hz / V
800 66 66
1,064 1,064
1,339 1,339
1,514 2,056 2,833 3,140 1,514 2,056 2,833 3,140 24 16 26 34 45 20 13 21 28 37 Centrifugal multi-blade, double suction 1,250 1,600 2,200 3,000 58 68 64 97 145 134 69 72 74 78 3/4 1 16 1~ / 50 / 230
90
0.35
0.47
674 349 17 9
1,064 581
800 63 66
0.59 1,339
1,514
1.42
FWD16AF FWD18AF 16.40 18.30 12.80 14.10 21.15 1,197 5.37 352x1,384x718 83 86 4.02 5.03 1.72
2,056 2,833 3,140 808 1,392 1,856 24 16 26 34 45 15 13 12 16 Centrifugal multi-blade, double suction 1,250 1,600 2,200 3,000 53 63 59 92 138 128 69 72 74 78 3/4 1 16 1~ / 50 / 230
FWV-DT/DF
Floor standing unit
FWV-DT/DF
›› ›› ›› ›› ›› ›› ›› ››
FWEC1, 2, 3A
ECFWMB6
Quick fixing system for wall mounted installation Pre-assembled 3-way/4-port on/off valves are available Valve packages are insulated, no extra drain pan required Valve packages contain balancing valves and sensor pocket Fast-on connections for electrical options: no tools needed The air filter can easily be removed for cleaning Electric heater: no relay up to 2kW capacity Electric heater: equipped with two overheat cut-out thermostats
Indoor unit Cooling capacity
Total capacity High Sensible capacity High Heating capacity 2-Pipe High 4-Pipe High Power input High Current input High HeightxWidthxDepth Dimensions Unit Weight Unit Heat exchanger Water volume Water flow Cooling Heating Water pressure Cooling drop Heating Fan Type Air flow rate High Sound power level High Piping connections Std. heat exchanger Drain OD Power supply Phase/Frequency/Voltage
kW kW kW kW W A mm kg l l/h l/h kPa kPa m³/h dBA inch mm Hz/V
2-PIPE 4-PIPE FWV01DT FWV02DT FWV03DT FWV04DT FWV06DT FWV08DT FWV10DT FWV01DF FWV02DF FWV03DF FWV04DF FWV06DF FWV08DF FWV10DF 1.54 2.09 2.93 4.33 4.77 6.71 8.02 1.46 1.90 2.87 4.33 4.67 6.64 7.88 1.20 1.51 2.11 3.15 3.65 4.91 5.96 1.14 1.51 2.07 3.15 3.57 4.85 5.85 2.14 2.57 3.81 5.63 6.36 7.83 10.03 1.90 2.10 3.08 5.05 5.30 7.91 9.30 37 53 56 98 137 175 37 53 56 98 137 175 0.17 0.24 0.25 0.44 0.43 0.60 0.76 0.17 0.24 0.25 0.44 0.43 0.60 0.76 564x774x226 564x984x226 564x1,194x226 564x1,404x251 564x774x226 564x984x226 564x1,194x226 564x1,404x251 19 20 25 30 31 41 20 21 26 32 33 44 0.5 0.7 1 1.4 2.1 0.5 0.7 1 1.4 2.1 265 359 504 745 820 1,154 1,343 251 327 494 745 803 1,142 1,355 265 359 504 745 820 1,154 1,343 196 182 286 396 465 694 816 13 11 12 14 12 19 13 11 12 14 12 19 9 11 9 10 9 16 7 8 5 10 8 9 Centrifugal multi-blade, double suction Centrifugal multi-blade, double suction 319 344 442 706 785 1,011 1,393 307 327 431 690 763 998 1,362 45 50 47 52 56 58 64 45 50 47 52 56 58 64 1/2 3/4 1/2 3/4 16 16 1~/50/230 1~/50/230
91
Air Coolers
Air coolers for big storage,freezing and working cold rooms with positive and negative temperature for the industry. The heat exchanger of the air cooler is made of high efficiency copper tubes with internal special helical profile for the water/glycol solution. Several models available with different fin spacings and for capacities from 1 up to more than 160 kW.
NHIW / HILW
HDIW
CHSW
LHSW
S2HCW
S3HCW
SHDNW / SHDSW
SHAW
92
VAM-FA
Heat reclaim ventilation
Clean outdoor air Total heat exchanged foul air
Total heat exchanged clean air
Foul indoor air
The Daikin heat reclaim ventilation system modulates the temperature and humidity of incoming fresh air to match indoor conditions. A balance is thus achieved between indoor and outdoor ambients, enabling the cooling or heating load placed on the air conditioning system to be reduced significantly. HRV units can be controlled individually or integral with the air conditioning system (Daikin VRV® or Sky Air series).
›› ›› ›› ›› ›› ›› ›› ››
Energy saving ventilation by recovery of indoor unit heat/cold Ideal solution for shops, restaurants or offices requiring maximum floor space for furniture, decorations and fittings Free cooling when outdoor temperature is below indoor temperature (eg. during night time) Can be used as stand alone unit or integrated in the VRV® system Wide range of units: air flow rate from 150 up to 2,000 m³/h Specially developed heat exchange element with High Efficiency Paper (HEP) No drain piping needed Can operate in over- and under pressure
[iPU]
Ventilation Fan-Air flow rate
Heat exchange mode Ultra high Bypass mode Ultra high Fan-External static pressure Ultra high Heat exchange mode Ultra high Sound pressure level Bypass mode Ultra high Temperature exchange efficieny Ultra high Enthalpy exchange Cooling Ultra high efficieny Heating Ultra high Heat exchange mode Nom. Ultra high Power input Ultra high Bypass mode Nom. HeightxWidthxDepth Dimensions Unit Weight Unit Connection duct diameter Operation range Min. Max. Relative humidity Operation mode Heat exchange system Heat exchange element Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)
m³/h m³/h Pa dBA dBA % % % kW kW mm kg mm °CDB °CDB %
VAM150FA 150 150 69 27 / 28.5 27 / 28.5 74
VAM250FA 250 250 64 28 / 29 28 / 29 72 58 64
0.116 0.141 0.116 0.141 285x776x525 24 100
VAM350FA 350 350
VAM500FA 500 500
98 32 / 34 33 / 34.5 32 / 34 33.5 / 34.5 75 61 58 65 62 0.194 0.212 0.194 0.212 301x828x816 33 150 200
VAM650FA 650 650 93 34.5 / 35.5 34.5 / 35.5 74
VAM800FA 800 800 137 36 / 37 36 / 37
60 63 65 0.380 0.451 0.380 0.451 364x1,004x868 48
VAM1000FA 1,000 1,000 157 36 / 37 36 / 37
VAM1500FA VAM2000FA 1,500 2,000 1,500 2,000 137 39.5 / 41.5 40 / 42.5 40.5 / 41.5 40 / 42.5 75 61 66 0.469 0.864 0.953 0.469 0.864 0.953 364x1,004x1,156 726x1,514x868 726x1,514x1,156 61 132 158 250 350
-15 50 80% or less Heat exchange mode / Bypass mode / Fresh-up mode Air to air cross flow total heat (sensible + latent heat) exchange Specially processed non-flammable paper 1~/50/60/220-240/220 15
Hz/V A
93
UATYQ-CY1
Rooftop - heat pump
Remote Control
UATYQ-CY1
›› ›› ›› ›› ›› ›› ›› ›› ›› ››
Easy to install ‘plug and play’ concept plus single installation configuration; no additional piping is required since indoor and outdoor sides are pre-connected High efficiency and reliable scroll compressor Wide operating range Flat top unit design allows maximum use of warehouse and container space Free cooling and fresh air intake possible with optional economiser Convertible return and supply air: fan can be mounted in two directions Factory pre-charged refrigerant ensures clean and efficient operation Belt driven fan enables air volume and static pressure to be adjusted as required. Adjustable fan pulley as standard to meet a wide range of supply air volumes and external static pressures Anti-corrosion treated coil
Plug and play installation
Heating & Cooling Indoor unit Cooling capacity Heating capacity Power input
Nom. Nom. Cooling Heating
Nom. Nom.
EER COP Evaporator
Air flow rate Cooling External static pressure Evaporator piping Condensation OD connections drain size Condenser Dimensions Unit HxWxD Weight Unit Casing Colour Material Air flow rate Cooling Operation range Cooling Min.~Max. Heating Min.~Max. Sound power level Nom. Refrigerant Type Power supply Phase/Frequency/Voltage
UATYQ250CY1 27.340 24.910 8.140 7.330 3.36 3.40 1,560
UATYQ350CY1 35.580 34.790 10.780 10.840 3.30 3.21 2,030 147
mm kg
1,150x1,638x2,063 445
1,028x2,209x2,113 580
cfm °CDB °CDB dBA
8,230
12,000
kW kW kW kW
l/s Pa
82
Hz/V
Weight Packing Fan Option for
ECONO250AY1 Packed unit
Unit Weight Air flow rate
Height Width Depth
Cooling Nom.
mm mm mm kg kg l/s cfm
UATYQ550CY1 55,690.000 53.930 16.740 15.540 3.33 3.47 3,160
UATYQ600CY1 66.820 61.690 19.650 18.580 3.40 3.32 3,445 206
UATYQ700CY1 72.600 69.610 21.610 21.420 3.36 3.25 3,917
1,302x2,209x2,670 830
1,454x2,209x2,670 970
20,200
21,200
25.4
mm
Economiser option Indoor unit Dimensions
UATYQ450CY1 44.720 41.790 13.040 12.860 3.43 3.25 2,670
1,130x2,209x2,113 1,048x2,209x2,670 610 780 Light grey Electro-galvanised mild steel 12,100 12,900 0~52 -15~20 83 87 R-410A 3~/50/380-415
ECONO350AY1
ECONO450AY1
90
ECONO550AY1
ECONO600AY1
ECONO700AY1
53 165 3,160 6,700 UATYQ550CY1
1,458 1,564 54 166 3,445 7,300 UATYQ600CY1
69 181 3,917 8,300 UATYQ700CY1
534 1,440 1,144 51 152 1,560 3,300 UATYQ250CY1
1,430 1,124 42 140 2,030 4,300 UATYQ350CY1
94
43 141 2,670 5,650 UATYQ450CY1
UATYP-AY1
Rooftop - heat pump
Remote Control
UATYP-AY1
›› ›› ›› ›› ›› ››
Easy to install ‘plug and play’ concept plus single installation configuration; no additional piping is required since indoor and outdoor sides are pre-connected Factory pre-charged refrigerant ensures clean and efficient operation Belt driven fan enables air volume and static pressure to be adjusted as required. Flat top unit design allows maximum use of warehouse and container space High efficiency and reliable scroll compressor Anti-corrosion treated coil
Heating & Cooling Indoor unit Cooling capacity Heating capacity Power input EER COP Evaporator
Nom. Nom. Cooling Heating
Nom. Nom.
Air flow rate Cooling External static pressure Evaporator piping Condensation OD connections drain size Condenser Dimensions Unit HxWxD Weight Unit Casing Colour Material Air flow rate Cooling Operation range Cooling Min.~Max. Heating Min.~Max. Sound power level Nom. Refrigerant Type Power supply Phase/Frequency/Voltage
kW kW kW kW
m³/min Pa mm mm kg
UATYP700AMY1 67.406 74.733 29.200 26.220 2.31 2.85 226
UATYP850AMY1 82.939 92.317 38.160 34.780 2.17 2.65 263
UATYPC10AMY1 101.110 102.290 43.170 41.670 2.34 2.45 312
UATYPC12AMY1 109.609 126.314 48.200 46.800 2.27 2.70 354
294 25.4 1,735x2,250x2,800 1,200
1,974x2,252x3,180 1,350
1,510
cfm °CDB °CWB dBA
Light grey Electro-galvanised mild steel 20,000 20~46 -15~20 -
Hz/V
3~/50/380-415
95
1,600
Air handling units
RANGE A wide standard range covers air flow rates from 500 m3/h up to 124.000 m3/h, with the possibility to choose the most appropriate transverse velocity, depending on the treatment required. In addition, with the same air flow, the flow section (width x height) can be adapted to the dimensional constraints of the installation. All sizes are modularly constructed to facilitate transport and easy assembly on site. With the absence of any welding points the Air Handling Units, on request, can be supplied completely dismantled to allow assembly directly on site. ›› P re-defined sizes Twenty-seven (27) fixed sizes optimized to reach the best compromise between competitiveness and manufacturing standardization. ›› “Infinitely” variable sizes designed to overcome installation constraints where space requirements of the section “width x height” must adapt to the available space. The system gives the possibility to tailor the unit sizes through increments/decrements of 5 cm. CONTROL Upon request all units can be provided with a regulation and control system that can manage the unit independently, or communicate with the external supervision system. Control panel power section, inverters, microprocessor, sensors to measure temperature, humidity and air quality, regulation valves, damper actuators, safety devices and control are just some of the components that can be installed upon request on the machine in order to provide an even more comprehensive product and faster installation.
96
Technical choices All the units were developed by paying special attention to energy efficiency. Exchange surfaces, motor efficiency, filtration, isolation, friction reduction and pressure drop in the air flow inside the Air Handling Units are just some of the most important parameters considered in the development of the design. All of this provides a product ready to be easily inserted in the system and capable of contributing to overall energy savings.
Frame Structure with carrier chassis built with anodized aluminum (suitable for installation in a particularly aggressive atmosphere) or aluminum profiles of 40x40 or 60x60mm sections. There are solutions with thermal break (60x60mm section) or radial profile (suitable for applications in the food sector or in general, where a high level of hygiene is required). All profiles are double chamber type so that the fixing screws are totally concealed and there are no projections inside the Air Handling Units (in compliance with current accidentprevention regulations), and they are also fitted with a gasket to be inserted inside the profile, in a dovetail slot, to ensure maximum seal. The structure is completed with three way connecting, nylon loaded glass joints put on corners while the base, independent for each section, is in extruded aluminum with aluminum pressure diecast corners to facilitate lifting. Panels The closing panels are double sheets, box-folded and can be flat (25 and 46mm thickness) or step type (42 and 62mm thickness). The step panels permit a flat surface inside the unit, ensuring continuity between the panel and the profile. Insulation can be made of polyurethane foam (40 รท 50 kg/m3) or fibrous mineral wool, glued to the panel (90 kg/m3).
Flat panel
Polyurethane foam
Step panel
Aluminium profile with thermal break
Fan-Motor Assembly The Fan-Motor is made with a single structure comprising two aluminum profiles which help to absorb transmitted shock and a motor, mounted on a tensioning slide. The structure never touches on the bottom of the unit because through the aluminum profiles transfer the weight onto the structure of the AHU, ensuring the maximum vibration isolation. With this solution it can be sure that the AHU does not transmit vibrations to any flat surface on which is installed.
Base
Tensioning slide
Structure with two aluminium profiles
97
Corner
Fittings The fasteners are stainless steel, self-tapping screws, located in nylon bosses and retained in the panel with an external cap. This system completely hides the screws in the panel and thanks to the self-fastening and self-centering screws, the tightness over time is ensured. Doors The doors for inspection and internal service can be provided with outward opening or inward opening for pressurized sections. There are solutions with hinges to allow left or right openings, or even the total removal of the door. Portholes The portholes are double-wall type made of polycarbonate and with sealing gaskets. The fastening system that provides the locking screws only enter the polycarbonate structure (and therefore not into the sandwich panel) and the continuous internal-external gasket, prevents the formation of condensation and ensures maximum sealing. Filters Particular attention is paid, during the configuration of the unit, to the position of the filters in the airflow, in order to maximize their effectiveness. All filters are mounted on commercial frames, provided with a seal to ensure effective filtration efficiency. In addition, all units are designed to allow the extraction of the filters from the dirt side in order to avoid possible contamination with the air circuit during maintenance.
FITTINGS
DOORS
PORTHOLES
FILTERS
the fasteners are stainless steel, self-tapping screws, located in nylon bosses and retained in the panel with an external cap. this system completely hides the screws in the panel and thanks to the self-fastening and self-centering screws, the tightness over time is ensured.
the portholes are double-wall type made of polycarbonate and with sealing gaskets. the fastening system that provides the locking screws only enter the polycarbonate structure (and therefore not into the sandwich panel) and the continuous internal-external gasket, prevents the formation of condensation and ensures maximum sealing.
COMPONENTS FILTER • Synthetic pleated filter • Flat filter aluminum mesh / SST 304 • Rigid / Soft bag filter • High efficiency filter • Carbon absorption / deodorizing filter EXCHANGERS • Water coils • Steam coils • Superheated water coils • Direct expansion coil • Electric coils
Humidifiers ›› Surface evaporation humidifier-constant loss water ›› Surface evaporation humidifier with re-circulating pump ›› Water spray humidifier constant loss water ›› Water spray humidifier with re-circulating pump ›› Steam humidifier with network distribution ›› Steam humidifier with local distributor ›› Atomized water spray humidifier
HUMIDIFIERS • Surface evaporation humidifier - constant loss water • Surface evaporation humidifier with re-circulating pum • Water spray humidifier - constant loss water • Water spray humidifier with re-circulating pump • Steam humidifier with network distribution • Steam humidifier with local distributor • Atomized water spray humidifier FANS • Forward curved fan • Backward curved fan • Plug fan (also available with direct coupling) Fastening
system Internal-external gasket
Fans ›› Forward curved fan ›› Backward curved fan ›› Plug fan (Also available with direct coupling) HEAT RECOVERY SYSTEMS ›› Heat wheel, sensible or enthalpy type ›› Cross-flow heat cube ›› Run-around coils OTHER SECTIONS ›› Attenuator section ›› Mixing box section with actuator or manual dampers ›› Empty section ›› Gas burner section ›› Factory mounted controls incl. Inverters
« Offering a complete range: from standard model sizes to customised solutions. » 98
Particular a unit, to the maximize th all filters ar a seal to en all units are from the d with the air
Hinges (left or right openings, or even the total removal of the door)
Available Components Filter ›› Synthetic pleated filter ›› Flat filter aluminum mesh / stainless steel 304 ›› Rigid / Soft bag filter ›› High efficiency filter ›› Carbon absorption / deodorizing filter Exchangers ›› Water coils ›› Steam coils ›› Superheated water coils ›› Direct expansion coil ›› Electric coils
the doors provided w pressurized allow left o the door.
PLUG and PLAY VRV® connection AHU
Air Handling Units for ›› VRV Indoor units and Air Handling Units on single VRV system ›› Monovalent cooling and heating for Air Handling Units ›› Air Handling Unit connection like standard VRV indoor unit ›› Factory engineered and mounted controls ›› Constant and comfortable supply air temperature control ›› Fast and easy installation ›› Standard DAIKIN warranty
With the new DAIKIN “PLUG and PLAY” VRV connection
In addition the Daikin Inverter technology for step-less
system VRV indoor units and Air Handling Units for
and efficient capacity control combined with the high-
fresh air treatment can be connected to the same re-
ly sophisticated factory engineered and mounted Air Han-
frigerant line, resulting in enhanced design flexibility
dling Unit controls are ensuring constant and comfort-
and increased energy efficiency. Both fresh air treat-
able supply air temperature.
ment and air conditioning can be achieved successfully
Last but not least not to forget about the business ad-
in a single direct-expansion system via DAIKIN VRV
vantages in which the DAIKIN “PLUG and PLAY” VRV con-
technology without the usual design problems of need-
nection will put you. The possibility of connecting the Air
ing VRV system for air conditioning and separate individ-
Handling Units together with the standard VRV indoor
ual heating and cooling systems just for the Air Handling
units in a monovalent heating and cooling VRV system
Units.
gives you the opportunity to completely get rid off the
The factory engineered and mounted controls package of
fossil fuel burning boilers, the chillers and the water piping
the Air Handling Units assures a fast and easy “PLUG and
from your projects and so reduce the total investment
PLAY” connection of the Air Handling Units just like a
cost significantly.
standard VRV indoor unit.
Altogether, the Daikin “PLUG and PLAY” VRV connection
This innovation brings a total monovalent direct-
system offers you the most efficient, easiest to install tech-
expansion solution to the heating, cooling and fresh
nology with lowest investment costs for the cooling and
air treatment demands of air conditioning applications.
heating needs of your air conditioning projects.
100
Factory engineered and mounted controls For all Air Handling Units of the “PLUG and PLAY” VRV connection system a factory engineered and factory mounted controls package is included.
This package consists of: ›› Expansion valve kits EKEXV which are already mounted inside the unit so that only the refrigerant piping has to be connected. ›› Factory mounted control equipment for the AHU like temperature-, pressure sensors, dampers … ›› Control panel to control the whole AHU based on supply temperature including EKEQMCB boxes. This assures a fast and easy “PLUG and PLAY” connection of the Air Handling Units to a VRV system just like a standard VRV indoor unit. The possibility of operating the Air Handling Unit by using standard DAIKIN remote control greatly simplifies overall system control. Using a centralized remote control enables the user to choose from a wide range of control systems that integrate air conditioning and ventilation in a single control system structure.
Standardized preconfigured Air Handling Units The following preconfigured Air Handling Units are especially designed to meet the requirements which go along with the “PLUG and PLAY” VRV connection system as well as to assure maximum energy efficiency and comfort level for standard air conditioning applications.
Preconfigured Air Handling Unit
+ 101
Factory mounted controls
Standard spec. supply air only units for cooling only applications These units are single air stream (Supply fan only) with integrated mixing box (0-100% fresh air) and can operate, if connected to DAIKIN VRV outdoor unit, in cooling mode only. Structure: Natural aluminum frame 40mm, Flat panel 25mm with foam insulation (40 ÷ 50 kg/m3), Skin material external Grey plastisol 0,7mm, Skin material internal galvanized 0,5mm Components in Order of the direction of air flow: 1) Mixing box with dampers including 1 x louver, 1 x flexible connection and factor fitted actuators, 2) F5 bag filter with factory mounted differential pressure gauge and hinged door, 3) Section for factory mounted expansion valve kits EKEXV 4) Direct expansion cooling coil with galvanized drain pan and droplet eliminator, 5) Supply fan (incl. hinged door, porthole, drive screen, mounted and wired light and on/off switch), 6) Flexible connection, 7) 150 mm base frame
Air flow m3/h Width Height Length Weight Cooling capacity total Cooling capacity sensible External static pressure Max. Power input fan
mm mm mm kg kW kW Pa kW
Included VRV connection kit Capacity index
2.000
3.000
4.000
6.000
8.000
10.000
12.000
950 800 3030 ~ 300 20,60 10,90 450 1,10
1000 930 3250 ~ 350 28,80 16,40 450 1,50
1150 950 3590 ~ 400 40,70 22,00 450 2,20
1350 1050 3360 ~ 470 58,70 32,90 450 3,00
1550 1050 3680 ~600 83,40 43,40 450 5,50
1550 1250 3950 ~700 100,30 55,20 450 5,50
1650 1300 4050 ~700 117,30 65,70 450 7,50
1 x EKEXV200 1 x EKEQMCB
1 x EKEXV250 1 x EKEQMCB
2 x EKEXV200 2 x EKEQMCB
2 x EKEXV250 2 x EKEQMCB
3 x EKEXV250 3 x EKEQMCB
4 x EKEXV200 4 x EKEQMCB
4 x EKEXV250 4 x EKEQMCB
1 x 184
1 x 257
2 x 182
2 x 262
3 x 248
4 x 224
4 x 262
Conditions: Outside air: Summer 35°C/50% r.H.; Supply air: Summer 19°C 1) Height including 150 mm Base frame 2) Width and Height without factory mounted control panel 3) EKEXVs mounted inside Air Handling unit. EKEQMCB mounted inside control panel 4) Maximum Connection Ratio (CR) of the total VRV system: 110% 5) Sum of Capacity Indexes of EKEXVs must not exceed 30% when used in a system with other indoor units
102
High spec. supply air only units for cooling only applications These units are single air stream (Supply fan only) with integrated mixing box (0-100% fresh air) and can operate, if connected to DAIKIN VRV outdoor unit, in cooling mode only. Structure: Natural aluminum frame 40mm, Step panel 42mm with mineral wool insulation (90 kg/m3), Skin material external Grey plastisol 0,7mm, Skin material internal galvanized 0,5mm Components in Order of the direction of air flow: 1) Mixing box with dampers including 1 x louver, 1 x flexible connection and factor fitted actuators, 2) Combined filter section G4 pre filter F7 bag filter with factory mounted differential pressure gauge and hinged door, 3) Section for factory mounted expansion valve kits EKEXV 4) Direct expansion cooling coil with galvanized drain pan and droplet eliminator, 5) Supply fan (incl. hinged door, porthole, drive screen, mounted and wired light and on/off switch), 6) Empty section, 7) Sound attenuator 500 mm, 8) F9 bag filter with factory mounted differential pressure gauge and hinged door, 9) Flexible connection, 10) 150 mm base frame
Air flow m3/h Width Height Length Weight Cooling capacity total Cooling capacity sensible External static pressure Max. Power input fan
mm mm mm kg kW kW Pa kW
Included VRV connection kit Capacity index
2.000
3.000
4.000
6.000
8.000
10.000
12.000
950 800 4820 ~ 500 20,6 10,9 450 1,50
1000 930 4980 ~ 570 28,8 16,4 450 2,20
1150 950 4970 ~ 650 40,7 22 450 3,00
1350 1050 5210 ~ 780 58,70 32,90 450 4,00
1550 1050 5310 ~ 860 83,40 43,40 450 5,50
1650 1250 5780 ~ 1080 100,30 55,20 450 7,50
1650 1300 5770 ~ 1170 117,30 65,70 450 11,00
1 x EKEXV200 1 x EKEQMCB
1 x EKEXV250 1 x EKEQMCB
2 x EKEXV200 2 x EKEQMCB
2 x EKEXV250 2 x EKEQMCB
3 x EKEXV250 3 x EKEQMCB
4 x EKEXV200 4 x EKEQMCB
4 x EKEXV250 4 x EKEQMCB
1 x 184
1 x 257
2 x 182
2 x 262
3 x 248
4 x 224
4 x 262
Conditions: Outside air: Summer 35째C/50% r.H.; Supply air: Summer 19째C 1) Height including 150 mm Base frame 2) Width and Height without factory mounted control panel 3) EKEXVs mounted inside Air Handling unit. EKEQMCB mounted inside control panel 4) Maximum Connection Ratio (CR) of the total VRV system: 110% 5) Sum of Capacity Indexes of EKEXVs must not exceed 30% when used in a system with other indoor units
103
Standard spec. supply and return air units for cooling / heating applications These units are double air stream (Supply and Return fan) with integrated mixing box (0-100% fresh air), heat recovery system (Pleat heat exchanger or rotary wheel) and can operate, if connected to DAIKIN VRV outdoor unit, in cooling and heating mode. Structure: Natural aluminum frame 40mm, Flat panel 25mm with foam insulation (40 ÷ 50 kg/m3), Skin material external Grey plastisol 0,7mm, Skin material internal galvanized 0,5mm Components in Order of the direction of air flow: Supply air stream: 1) Dampers section including 1 x louver, and factor fitted actuators, 2) F5 bag filter with factory mounted differential pressure gauge and hinged door, 3) Heat recovery system (Pleat heat exchanger or rotary wheel), 4) Mixing box with damper and factor fitted actuators, 5) Direct expansion cooling coil with galvanized drain pan and droplet eliminator, 6) Supply fan (incl. hinged door, porthole, drive screen, mounted and wired light and on/off switch), 7) Flexible connection, 8) 150 mm base frame Return air stream: 1) G4 flat filter with factory mounted differential pressure gauge and hinged door, 2) Return fan (incl. hinged door, porthole, drive screen, mounted and wired light and on/off switch), 3) Mixing box with damper and factor fitted actuators, 4) Heat recovery system (Pleat heat exchanger or rotary wheel), 5) Dampers section including 1 x louver, and factor fitted actuators
Air flow m3/h Width Height Length Weight Cooling capacity total Cooling capacity sensible Heating capacity total External static pressure Max. Power input supply fan Max. Power input return fan Included VRV connection kit Capacity index
mm mm mm kg kW kW kW Pa kW kW
2.000
3.000
4.000
6.000
8.000
10.000
12.000
950 1450 2960 ~ 550 20,6 10,9 11,25 450 1,10 1,10
1000 1710 3440 ~ 680 28,8 16,4 16,50 450 2,20 1,50
1150 1750 3190 ~ 700 40,7 22 21,30 450 2,20 2,20
1350 1950 3330 ~ 900 58,70 32,90 32,26 450 4,00 3,00
1550 1950 3730 ~ 1020 83,40 43,40 44,40 450 5,50 4,00
1650 2350 3700 ~ 1270 100,30 55,20 57,91 450 5,50 5,50
2000 2350 4020 ~ 1560 117,30 65,70 78,31 450 11,00 7,50
1 x EKEXV200 1 x EKEQMCB
1 x EKEXV250 1 x EKEQMCB
2 x EKEXV200 2 x EKEQMCB
2 x EKEXV250 2 x EKEQMCB
3 x EKEXV250 3 x EKEQMCB
4 x EKEXV200 4 x EKEQMCB
4 x EKEXV250 4 x EKEQMCB
1 x 184
1 x 257
2 x 182
2 x 262
3 x 248
4 x 224
4 x 262
Conditions: Outside air: Summer 35°C/50% r.H., Winter -15°C/90% r.H.; Supply air: Summer 19°C, Winter 26°C 1) Height including 150 mm Base frame 2) Width and Height without factory mounted control panel 3) EKEXVs mounted inside Air Handling unit. EKEQMCB 4) Maximum Connection Ratio (CR) of the total VRV system: 110% 5) Sum of Capacity Indexes of EKEXVs must not exceed 30% when used in a system with other indoor units
104
High spec. supply and return air units for cooling / heating applications These units are double air stream (Supply and Return fan) with integrated mixing box (0-100% fresh air), heat recovery system (Pleat heat exchanger or rotary wheel) and can operate, if connected to DAIKIN VRV outdoor unit, in cooling and heating mode. Structure: Natural aluminum frame 40mm, Step panel 42mm with mineral wool insulation (90 kg/m3), Skin material external Grey plastisol 0,7mm, Skin material internal galvanized 0,5mm Components in Order of the direction of air flow: Supply air stream: 1) Dampers section including 1 x louver, and factor fitted actuators, 2) Combined filter section G4 pre filter F7 bag filter with factory mounted differential pressure gauge and hinged door, 3) Heat recovery system (Pleat heat exchanger or rotary wheel), 4) Mixing box with damper and factor fitted actuators, 5) Direct expansion cooling coil with galvanized drain pan and droplet eliminator, 6) Supply fan (incl. hinged door, porthole, drive screen, mounted and wired light and on/off switch), 7) Empty section, 8) Sound attenuator 500 mm 9) F9 bag filter with factory mounted differential pressure gauge and hinged door 10) Flexible connection, 11) 150 mm base frame Return air stream: 1) F6 bag filter with factory mounted differential pressure gauge and hinged door, 2) Return fan (incl. hinged door, porthole, drive screen, mounted and wired light and on/off switch), 3) Mixing box with damper and factor fitted actuators, 4) Heat recovery system (Pleat heat exchanger or rotary wheel), 5) Dampers section including 1 x louver, and factor fitted actuators
Air flow m3/h Width Height Length Weight Cooling capacity total Cooling capacity sensible Heating capacity total External static pressure Max. Power input supply fan Max. Power input return fan Included VRV connection kit Capacity index
mm mm mm kg kW kW kW Pa kW kW
2.000
3.000
4.000
6.000
8.000
10.000
12.000
950 1450 4740 ~ 830 20,6 10,9 11,25 450 1,50 1,10
1000 1710 5170 ~ 990 28,8 16,4 16,50 450 2,20 1,50
1150 1750 4900 ~ 1070 40,7 22 21,30 450 3,00 2,20
1350 1950 5050 ~ 1301 58,70 32,90 32,26 450 4,00 3,00
1550 1950 5560 ~ 1520 83,40 43,40 44,40 450 5,50 4,00
1650 2350 5580 ~ 1835 100,30 55,20 57,91 450 7,50 5,50
1650 2350 5760 ~ 2230 117,30 65,70 78,31 450 11,00 7,50
1 x EKEXV200 1 x EKEQMCB
1 x EKEXV250 1 x EKEQMCB
2 x EKEXV200 2 x EKEQMCB
2 x EKEXV250 2 x EKEQMCB
3 x EKEXV250 3 x EKEQMCB
4 x EKEXV200 4 x EKEQMCB
4 x EKEXV250 4 x EKEQMCB
1 x 184
1 x 257
2 x 182
2 x 262
3 x 248
4 x 224
4 x 262
Conditions: Outside air: Summer 35°C/50% r.H., Winter -15°C/90% r.H.; Supply air: Summer 19°C, Winter 26°C 1) Height including 150 mm Base frame 2) Width and Height without factory mounted control panel 3) EKEXVs mounted inside Air Handling unit. EKEQMCB mounted inside control panel 4) Maximum Connection Ratio (CR) of the total VRV system: 110% 5) Sum of Capacity Indexes of EKEXVs must not exceed 30% when used in a system with other indoor units
105
OPTIONS & ACCESSORIES Chillers Fan coil units Ventilation
108 112 114
107
Options - chillers Integrated Hydronics Type
Compr.
Refr
SWING
R-410A
Air Cooled
R-410A
SCROLL R-407C
CondenWater serless Cooled chiller
R-410A
Mode
Reference
Products
EWAQ-ACV3 EWYQ-ACV3 EWAQ-ACV3 EWAQ-ACW1 EWYQ-ACV3 EWYQ-ACW1 EUWAC-FBZW1 EUWAN-KBZW1 EUWAP-KBZW1 EUWAB-KBZW1 EUWYN-KBZW1 EUWYP-KBZW1 EUWYB-KBZW1 EWAQ-DAYNN EWYQ-DAYNN
005-006-007 005-006-007 009-010-011 009-011-013 009-010-011 009-011-013 5-8-10 5-8-10-12-16-20-24 5-8-10-12-16-20-24 5-8-10-12-16-20-24 5-8-10-12-16-20-24 5-8-10-12-16-20-24 5-8-10-12-16-20-24 080-100-130-150-180-210-240-260 080-100-130-150-180-210-240-260
SCROLL
R-407C
EWWP-KBW1N
014-022-028-035-045-055-065
SCROLL
R-407C
EWLP-KBW1N
012-020-026-030-040-055-065
Nomenclature for air-cooled B and C series: E W A D 4 1 2 3 4 5
6 6
0 7
B 8
Z X S 9 10 11
9 Inverter -: non-inverter Z: inverter
Description
code
Total heat recovery Total heat recovery 1 circuit Partial heat recovery Direct on line starter Wye delta starter (y - d) Soft starter Heat pump version Brine version Double set point Compressor thermal relays Fans circuit breakers with thermal overload relays Phase monitor Inverter compressor starter Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Evaporator victaulic kit Evaporator flange kit Evaporator Marine WaterBox VICTAULIC (1 Pass) Evaporator marine waterbox victaulic (2 step) Evaporator marine waterbox victaulic (3 step) Evaporator Marine WaterBox FLANGED (1 Pass) Evaporator marine waterbox flanged (2 step) Evaporator marine waterbox flanged (3 step) Condenser double flanges kit Evaporator water side design pressure 10 bar Evaporator water side design pressure 25 bar 20 mm evaporator insulation Axial fans 100 pa lift Axial fans 250 pa lift 20mm condenser insulation Fan silent mode Fans speed control device (phase cut on fan) Condenser victaulic kit Condenser flange kit Condenser Marine WaterBox VICTAULIC (1 Pass) Condenser Marine WaterBox VICTAULIC (2 Passes) Condenser Marine WaterBox VICTAULIC (3 Passes) Condenser Marine WaterBox FLANGED (1 Pass) Condenser Marine WaterBox FLANGED (2 Passes) Condenser Marine WaterBox FLANGED (3 Passes) Speedtrol (fan speed control device - on/off - up to -18°c) Condenser coil guards Evaporator area guards Cu-cu condenser coil Cu-cu sn condenser coil Condenser water side design 16 bar Condenser water side design 21 bar Alucoat fins coil Cu-ni 90-10 condenser tubes
01 02 03 04 05 06 07 08 10 11 12 13 14 15 16 17 19 20 21 22a 22 23 24a 24 25 26 27 28 29 30 32 33 34 35 36 37 38a 38 39 40a 40 41
10 Efficiency level S: Standard X: High P: Premium
Twin pump contact
Single pump
Twin pump
High ESP pump
OPSC
OPTC
OPSP
OPTP
OPHP
STD STD STD STD STD STD
• •
• •
• •
• •
• • • •
• •
(s) OP12 & OP03 need to be added to meet Swedish national law 1992: 16 (1) Impossible option combination: OPZH+OPZL (2) Not available with option OPLN
11 Sound level S: Standard L: Low R: Reduced
EWAQ~BA EWAD-BZ EWWD~G-XS EWWD~I-XS EWWD-J-SS EWAD~CZ EWAD~CF EWWQ~B- EWAD~D- EWAD~E- ERAD~EEWLD~G-SS EWLD~I-SS EWWD~FZXS EWAD~CEWWD~HEWYQ~BA EWYD-BZ EWWD~G-SS EWWD~I-SS EWLD-J-SS Option Option Option
Option STD STD STD STD Option Option Option STD
Option
Option (1) Option Option (1) Option Option (1) Option
Option
Option
Option
Option
STD Option
STD Option
STD Option
STD Option
STD Option
Option STD STD
Option STD Option
Option STD Option
STD
STD
Option STD Option STD STD
Option STD Option STD STD
Option STD Option
STD STD Option Option
Option STD Option STD STD
STD Option Option Option STD Option STD
STD
Option
Option STD Option
Option
STD
Option Option Option Option
Option Option Option Option STD
STD
STD
STD (14) STD (15)
Option Option Option
Option
Option
Option Option Option Option
Option Option Option Option
Option Option Option Option STD (2) Option (2)
Option Option Option Option
Option Option Option Option
STD
Option Option (2) Option cf cf Option Option Option cf Option
1. Heat exchangers are placed in series 2. Please note the following option availability: - Group 1: EWAD180-200D-SL; EWAD180-190D-SR; EWAD210D-SX; EWAD200-210D-HS - Group 2: all other models Group 1 Group 2 Option 20 N/A STD Option 21 N/A Option Option 29 STD Option 3. Option 42 is ‘N/A’ for EWAD-D-SX version
Option
Option
Option
Option
Option
STD Option
STD Option Option Option STD
STD Option
STD Option
Option STD
STD
STD
Option STD Option STD STD
Option
Option STD
STD
Option
Option
Option
Option
Option Option Option Option STD
Option STD Option Option
Option Option Option Option STD
STD Option Option
Option STD STD Option Option Option Option Option Option Option Option STD Option STD
Option Option Option Option STD Option
STD
STD Option Option Option STD Option
STD CF Option Option Option Option STD
STD Option Option Option Option STD
Option Option Option Option STD
STD
STD
Option
Option
Option
Option
Option
STD Option Option Option Option Option Option Option
STD (17)
STD Option Option Option Option Option Option
Option
Option
Option
Option
Option Option
Option Option
Option Option
Option Option Option Option
Option
STD CF Option Option STD Option
Option
Option
STD
STD
STD Option
Option
Option
Option
Option
CF
STD (1)
STD
Option
4. Option 56 is ‘STD’ for EWAD180-200D-SL; EWAD180-190D-SR; EWAD200-210D-HS 5. One ‘High pressure side manometer’ per circuit 6. * Low lift 8m – high lift 12m (nominal condition) * Option 80/81 is ‘N/A’ for EWAD180-190D-SR; 78/79/80/81 is ‘N/A’ for EWAD-D-SX version 7. Option 99 is ‘STD’ for EWAD-D-SX version 8. Not available for 2 smallest models 9. Not available for high efficiency range 10. Tank delivered separately
108
Option Option Option Option STD
Option (3) Option
Option Option
Option Option Option Option STD
Option
STD Option
Option (9)
STD
STD
42 43 44 45 46 47 48 49 50
Single pump contact
Option
11. Not available for standard efficiency range 13. Only available for EWAD~BZ range 14. Fan silent mode is an option for EWYD~BZSS 15. Only for EWYD~BZSL, option for EWYD~BZSS 16. Not available for EWYD~BZ 17. Not available for condenserless range 18. Only available for condenserless range * Option 76 is standard available for the versions with reduced / extra low sound level
Noise & Head Pressure Control
LWE
Electrical
Buffer tank
Low noise
Inverter fans
High ESP fans
High Glycol
Low Glycol
Evaporator heater tape
OPBT
OPLN
OPIF
OPHF
OPZH
OPZL
OP10
Main switch
Refrigerant
Condenser
A / V meter
Dual pressure relief valve
Suction stop valve
Coil guards
OP52
OP57
OP03
OP12
OPCG
STD STD
• •
• •
•(s) •(s)
• •
STD STD STD STD STD STD • • • • • •
STD
STD • •
Description
• •
• • • • • • •
• • • • • • • • •
•(2) •(2)
code
•
•
•
•
• • • • • • • •
EWWD-J-SS EWAQ~BA EWAD-BZ EWWD~G-XS EWWD~I-XS EWLD~I-SS EWWD~FZXS EWAD~CEWWD~HEWAD~CZ EWAD~CF EWWQ~B- EWAD~D- EWAD~E- ERAD~EEWLD~G-SS EWYQ~BA EWYD-BZ EWWD~G-SS EWWD~I-SS EWLD-J-SS
Condenser 1 pass (dt 4-8 °c) 51 Condenser 2 passes (dt 4-8 °c) 52 Condenser 2 passes (dt 9-15 °c) 53 Condenser 3 passes 53b Condenser 4 passes 54 Water pressure differential switch on condenser 55 Water pressure differential switch on evaporator 56 Evaporator electric heater 57 Option STD STD Evaporator flow switch 58 Option Option Condenser flow switch 59 Electronic expansion device 60 STD STD Discharge line shut off valve 61 STD STD Suction line shut off valve 62 STD Option High pressure side manometers 63 Option Option Low pressure side manometers 64 STD Additional capacity reduction steps 65 Ambient outside temperature sensor 67 STD and set-point reset Hour run meter 68 STD STD General fault contactor 69 STD STD Container kit 71 Option Option Fork-lift kit 72 Wooden box packing 74 Rubber anti vibration mount 75 Option Option Sound proof system* 76 Spring anti vibration mount 77 Option Option One centrifugal pump (low lift) 78 Option Option One centrifugal pump (high lift) 79 Option Option Two centrifugal pumps (low lift) 80 Option Option Two centrifugal pumps (high lift) 81 Option Witness test 82 External tank without cabinet (500 l) 83 Option External tank without cabinet (1000 l) 84 Option External tank (500 l) with cabinet RAL7032 87 Option External tank (1000 l) with cabinet RAL7032 88 Option Acoustic test 89 Set-point reset, 90 Option STD demand limit and alarm from external device Double pressure relief valve with diverter 91 Option Option Low ambient kit for 1 circuit 93 Low ambient kit for 2 circuits 94 Compressor circuit breakers 95 Option Fans circuit breakers 96 STD Main switch interlock 97 STD (16) STD Emergency stop 98 Option Fan speed regulation 99 STD (16) Option Refrigerant recovery tank 100 Option Evaporator right water connection 101 Option Ground fault relay 102 Option Evaporator 1pass 103 Evaporator 2 passes 103a Evaporator 3 passes 103b Evaporator Double Flange Kit 104 Liquid receiver 105 Rapid restart 110 Option High temperature kit 111 Transport kit 112 Option Option Option Glycol function .. Option Optimized free cooling ..
STD (9) STD (11) Option (9)
Option (4) STD STD Option Option
Option
Option Option
STD STD Option Option Option
STD STD STD Option STD STD Option STD STD STD Option (5) Option STD
STD STD STD
Option
STD STD Option
Option Option
Option Option
Option Option Option
Option
STD
STD STD Option
STD STD Option
Option
Option
Option
STD STD (9)
STD STD
STD (17) STD Option
Option
Option Option STD Option Option STD
STD Option Option STD
STD STD (11) STD STD STD STD Option Option Option
STD STD Option
STD STD Option
Option
Option Option
STD STD Option
Option Option STD
Option
STD
Option
Option STD
STD
Option STD Option STD STD Option STD
STD STD STD STD STD Option
Option Option STD STD Option Option Option
STD
Option Option
Option Option
STD STD
STD STD Option
STD STD
STD STD Option
Option Option Option
Option Option
Option
Option Option
Option Option
CF
Option
CF
Option Option Option Option (6) Option (6) cf Option Option Option Option cf
CF
CF
CF
CF
CF
STD
STD
Option
STD
STD
STD
STD
STD
STD
STD
STD
Option
STD
Option
STD
Option
Option
Option
Option
Option
Option
Option
STD
Option
Option
Option
Option STD STD
Option STD STD
Option STD STD
Option
Option
Option
STD STD
STD STD
CF
Option Option STD Option Option
Option CF
Option STD STD STD Option
Option Option Option Option Option (8) Option (8) cf cf Option Option Option Option cf cf
Option
STD STD Option Option STD
Option STD
Option Option Option CF
CF
CF
CF
CF
CF
STD Option Option Option Option
Option (7)
Option Option STD
STD Option STD
Option
Option
Option
Option Option
Option
Option
Option
109
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option Option
Accessories - chillers Air cooled chillers EWA/YQ009-011ACV3 EWA/YQ009-013ACW1 Panels EKDSSP EKDSSP-S*** EKDDSP EKPWPRO EKPWPROM Serial Cards & Comm. Modules EKAC10C EKACPG EKAC200A EKAC200J EKACBAC EKACLON EKACLONP EKACRS232 EKACWEB EKACBACMSTP EKACBACCERT EKCM200J EKCMLON EKCMBACMSTP EKCMBACIP LON Gateway EKLONPG Other Systems & Accessories EKCLWS EKCON EKCONUSB EKMODEM EKGSMOD EKRP1HB EKRUPCJ EKRUPCK EKRUPCS EKPV2J EKPWPROEXT EKGWWEB EKGWMODEM EKBNPG EKBMSBNA EKBMSMBA EKRUMCA EKRUPC EKRUPG EHMC*AV1010 EHMC*AV1080 EKRP1AHTA DTA104A62 EKRUAHTB Gauges EKGAU5/8KA EKGAU10/12KA EKGAU16KA EKGAU20/24KA BHGP26A1 Soft starter EKSS Buffer tank EKBT Waterpipe kit EKGN210
EUWAC-FBZW1
EUWA/Y*-KBZW1
EWA/YQ~BA*
EWAD~D-
EWA(Y)D~BZ
• •
•
•
EWAD~C-
•
• • • •
• • • •
• • • •
• • • • •
•
• •
•
• • •
• •
• • • • (5-8) • (10-12) • (16) • (20-24)
•
• • • (080-210) • (EWAQ240-260DAYN & EWYQ230-250DAYN)
EKGN260 * To install EKRUMCA => EKAC10C needs to be installed on the unit.
EWA/YQ-DAYN
* EKAC10C allows direct connection to MODBUS BMS system
110
* To install EKLONPG & EKBNPG => EKACPG needs to be installed on the unit.
•
Water cooled chillers EWAD~CZ
EWAD-CF
• •
• •
EWWP-KBW1N
•
EWLP-KBW1N
Centrifugals
EWW(L)D~G-
EWW(L)D~I-
EWWD~H-
EWWQ~B-
EWW(L)D~J-
EWWD~FZXS
• •
• •
• •
• •
• •
• • • •
•
• • • •
• • • •
•
•
• • • •
• • • •
•
•
•
• •
• (014-045)
• • •
• • • •
•
• • • •
•
• • • •
• • • • • • • •
• • • •
• • • •
• • • •
•
•
• • • •
• • • •
DWSC & DWDC
• (012-030)
111
• • •
Options - fan coil units Type: FWM-DT/DF, FWL-DT/DF, FWV-DT/DF Description Additional single row heat exchanger Electric heater 2-pipe 3-way valve 4-pipe 3-way valve Fan stop thermostat Air intake & discharge grille Supporting feet Supporting feet + grille Fresh air intake Rear panel Control electromechanical Electronic controller Master slave option Vertical drainpan Horizontal drainpan Temperature sensor kit Relative humidity sensor kit On board FCU controller installation kit Wall mounting kit (spacing collar) for FWEC*A
1
2
3
4
ESRH02A6 EEH01A6 EEH02A6 E2MV03A6 E4MV03A6
ESRH03A6 EEH03A6
EAIDF02A6
EAIDF03A6 ESFV06A6 ESFVG3A6 EFA3A6 ERPV3A6
ESFVG2A6 EFA2A6 ERPV2A6
Type: FWB-BT Description Additional heat exchanger 3-way valve add. h/e 3-way valve cooling h/e 2-way valve add. h/e 2-way valve cooling h/e Electric Heater Fan stop thermostat Master slave interface Electronic controller Temperature sensor kit Relative humidity sensor kit On board installation kit Wall mounting kit (spacing collar) for FWEC*A
6
10 ESRH10A6 EEH10A6 E2MV10A6 E4MV10A6 EAIDF10A6 ESFV10A6 ESFVG10A6 EFA10A6 ERPV10A6
ESFVG6A6 EFA6A6 ERPV6A6 ECFWMB6 FWEC1A, FWEC2A, FWEC3A EPIMSB6 EDPVA6 EDPHA6 FWTSKA FWHSKA FWECKA FWFCKA
FWV
FWL
FWM
x x x x x x x x x x x x x x x x x
x x x x x x x x x x x x x x x
x x x x x x x x x x x x x x x
2-4
5-7
8-10
EAH04A6
EAH07A6
EAH10A6 E2MV310A6
E2MV307A6 Factory mounted E2MV207A6
E2MV210A6 Factory mounted Factory mounted YFSTA6 EPIMSB6 FWEC1A, FWEC2A, FWEC2A FWTSKA FWHSKA FWECKA FWFCKA
Type: FWB-JT/JF Description 2-pipe 3-way valve 4-pipe 3-way valve Electronic controller
8
ESRH06A6 EEH06A6 E2MV06A6 E4MV06A6 YFSTA6 EAIDF06A6
02 - 11 MCWCN MCWHN (3)
FWEC1A, FWEC2A, FWEC3A
Master slave interface
EPIMSB6
Temperature sensor kit
FWTSKA
Relative humidity sensor kit
FWHSKA
Wall mounting kit (spacing collar) for FWEC*A
FWFCKA
Type: FWD-AT/AF Description Electric heater: small (1) Electric heater: big 2-pipe 3-way valve (2) 4-pipe 3-way valve Vertical Drainpan Horizontal Drainpan Fan stop thermostat Fresh air intake Electronic controller (3) Power interface Master slave interface Temperature sensor kit Relative humidity sensor kit Wall mounting kit (spacing collar) for FWEC*A
4
6
EDEH04A6 EDEH04A6 ED2MV04A6 ED4MV04A6
EDEHS06A6 EDEHB06A6
8
EDMFA04A6
EDMFA06A6
10
EDEHS10A6 EDEHB10A6 ED2MV10A6 ED4MV10A6 EDDPV10A6 EDDPH10A6
12 EDEHS12A6 EDEHB12A6 ED2MV12A6 2xED2MV12A6
YFSTA6 EDMFA10A6 EDMFA12A6 FWEC1A, FWEC2A, FWEC3A -
Requires electronic controller For FWD 12,16,18AT/AF only motor valve (piping not included) Water probe included Optional, electrical installation box with earth terminal KJB212A is required, if controller wires need to be installed in the wall. Requires electrical installation box with earth terminal KJB311A. Requires electrical installation box KJB411A. Requires installation box KRP1H98. (FWC) Requires installation box KRP1BA101 (FWF) Requires electrical installation box with earth terminal KJB212A, if built in the wall. Requires valve control PCB EKRP1C11 I-touch: • Not allowed to use the i-touch for an installation with both fan coils and VRV units. • Can not be used in combination with fan coil units, that use MOD bus communication. • No Airnet or telephone connection possible. 12. Only 1 of these 4 options can be installed on 1 indoor unit. 13. Max. 1 KRP1H98 box can be mounted on the unit. Max. 2 PCB’s can be mounted in 1 KRP1H98 box. (FWC) 14. Max. 2 KRP1BA101 boxes can be mounted on the unit. Max. 1PCB can be mounted in 1 KRP1BA101 box. (FWF)
112
18
EDEHS18A6 EDEHB18A6 ED2MV18A6 2 x ED2MV18A6 EDDPV18A6 EDDPH18A6 EDMFA18A6 EPIB6
EPIMSB6 FWTSKA FWHSKA FWFCKA
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11.
16
TYPE Description Decoration Panel (RAL 9010 - grey sealings) 4-way blow Decoration Panel - Standard (RAL 9010 - grey sealings) Round flow Decoration Panel - White (RAL 9010 - white sealings) Round flow Sealing member of air discharge outlet Panel spacer Long-life filter Fresh air intake kit - Direct installation type Fresh air intake kit (20% fresh air) - Direct installation type Remote controller - Wireless - H/P Remote controller - Wireless - C/O Remote controller - Wired Central remote controller Electrical box with earth terminal (3 blocks) Unified on/off controller Electrical box with earth terminal (2 blocks) Schedule timer Wiring adapter for electrical appendices (1) Wiring adapter for electrical appendices (2) Installation box for adapter PCB Remote sensor Intelligent touch controller Electrical installation box Optional PCB for MOD-bus connection 2-way valve - On/Off 3-way valve - On/Off Valve control PCB Remote “On/Off” and “forced off” kit
Description Standard wired remote controller with LCD Simplified wired remote controller (cooling only) Simplified wired remote controller (heat pump) Wireless controller for cooling only Wireless controller for heat pump Decoration panel (600x600) including wireless controller H/P 2pipes Decoration panel (900x900 / 2-pipe) including wireless controller H/P 2pipes Decoration panel (900x900 / 4-pipe) including wireless controller H/P 4pipes 2-pipe 3-way valve 2-pipe 3-way valve 4-pipe 3-way valve
FWC-BT/BF
FWF-BT/BF
BYCQ140CW BYCQ140CW KDBHQ55C140 KAFP551K160 CE.KDDQ55C140 BRC7F532F (*18) BRC7F533F (*18)
BYFQ60B
KDBH44BA60 KDBQ44B60 KAFQ441BA60 KDDQ44XA60 BRC7E530 (*18) BRC7E531 (*18) BRC315D (*4) DCS302C51 (*5) KJB311A DCS301B51 (*9) KJB212A
DST301B51 (*6)(*9) KRP2A52 (*7) (*12) KRP4AA53 (*7) (*12) KRP1H98 (*13) KRCS01-4 DCS601C51(*6) (*11)
DST301B51 (*6)(*9) KRP2A52 (*9) (*12) KRP4AA53 (*9) (*12) KRP1BA101 (*14) KRCS01-1 DCS601C51 (*6) (*11) KJB411A
EKFCMBCB (*8) (*12) EKMV2C09B (*8) (*10) (*15) EKMV3C09B (*8) (*10) (*15)
EKFCMBCB (*8) (*12) EKMV2C09B (*8) (*10) (*16) EKMV3C09B (*8) (*10) (*16) EKRP1C11 EKRORO (*17)
material MERCA SRC-COA SRC-HPA WRC-COB WRC-HPB DCP600TB DCP900TB DCP900FB MCKAW2T3VN MCKCW2T3VN MCKAWH4T3VN
FWT-BT x x x x x -
FWF-CT x x x x x x x -
15. 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve control PCB EKRP1C11 4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve control PCB EKRP1C 11 (FWC) 16. 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11 4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11 (FWF)» 17. This option is needed to create T1 T2 wire. 18. It is possible to change the operation mode, but this will not have an impact on the water temperature. (No feed back to water source) It is not possible to select the “auto airflow” setting. Dry operation can be selected with this remote control, but this function is not available on the FWC model. 19. All options are supplied as kit. 20. Both parts of the fresh air intake are needed for each unit.
113
FWC-AT x x x x x x x -
FWC-AF x x x x x
Options & accessories - ventilation
OTHERS
ERQ100-125AV1
ERQ140AV1
Central drain pan Central drain plug
KKPJ5F180
VAM wired remote control
CENTRALISED CONTROL SYSTEMS
KWC26B280
KRC19-26A6
Fixing box
Wired remote control
ERQ200-250AW1
KWC26B160 KKPJ5F180
Cool/heat selector
INDIVIDUAL CONTROL SYSTEMS
ERQ125AW1
KJB111A
VAM-FA
EKEQFCB 2
EKEQDCB 2
EKEQMCB 2
BRC1E52A / BRC1D52
BRC1E52A / BRC1D52
BRC1E52A / BRC1D52
BRC1E52A / BRC1D52
EKEQFCB 2
EKEQDCB 2
EKEQMCB 2
EKEQFCB 2
EKEQDCB 2
EKEQMCB 2
BRC301B61
VAM-FA
Centralised remote control
DCS302C51
Unified ON/OFF control
DCS301B51
Schedule timer
DST301B51
OTHERS
VAM-FA
Wiring adapter for electrical appendices (control and monitoring F1 F2)
KRP2A61
Wiring adapter for electrical appendices (control and monitoring P1 P2)
KRP4A51
Adapter for humidifier (running ON signal output)
KRP50-2
Adapter for heater control kit
BRP4A50
Remote sensor
KRCS01-1
Notes (2) Do not connect the system to DIII-net devices (Intelligent controller, Intelligent Manager, LonWorks interface, BACnet interfaceâ&#x20AC;Ś).
114
POWER SUPPLY T1 = 3~, 220V, 50Hz V1 = 1~, 220-240V, 50Hz VE = 1~, 220-240V/220V, 50Hz/60Hz* V3 = 1~, 230V, 50Hz VM = 1~, 220~240V/220~230V, 50Hz/60Hz W1 = 3N~, 400V, 50Hz Y1 = 3~, 400V, 50Hz * For VE power supply only 1~, 220-240V, 50Hz data is displayed in this catalogue.
MEASURING CONDITIONS AIR CONDITIONING 1) nominal cooling capacities are based on: Indoor temperature Outdoor temperature Refrigerant piping length Level difference 2) nominal heating capacities are based on: Indoor temperature Outdoor temperature Refrigerant piping length Level difference
27°CDB/19°CWB 35°CDB 7.5m - 8/5m VRV 0m 20°CDB 7°CDB/6°CWB 7.5m - 8/5m VRV 0m
APPLIED SYSTEMS Air cooled
Cooling only Heat pump
Water cooled
Cooling only
Evaporator: 12°C/7°C Ambient: 35°CDB Evaporator: 12°C/7°C Ambient: 35°C Condenser: 40°C/45°C Ambient: 7°CDB/6°CWB Evaporator: 12°C/7°C Condenser: 30°C/35°C Evaporator: 12°C/7°C Condenser: 40°C/45°C Evaporator: 12°C/7°C Condensing temperature: 45°C / Subcooling: 5 K Room temperature: 27°C/19°C Entering water temperature: 7°C/12°C Room temperature: 20°C Water inlet temperature: 50°C (2-pipe)/70°C (4-pipe)
Heating only Condenserless chiller Fan coil units
Cooling Heating
The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment (for measuring conditions: please refer to the technical databooks). The sound power level is an absolute value indicating the “power” which a sound source generates. For more detailed information please consult our technical databooks. 115
Environmental awareness European Union’s
20-20-20 energy targets
In March 2007, after years of worldwide concern, the European heads of state endorsed “an integrated
approach to climate and energy policy that aims to combat climate change and increase the EU’s energy security while strengthening its competitiveness. They committed Europe to transforming itself into a highly energy-efficient, low carbon economy.” (http://ec.europa.eu) To turn this into a reality, a series of challenging climate and energy objectives were set and became known as the 20-20-20
energy targets, which are to be met by 2020 and these are:
C02 -20% CO2 emissions vs. 1990
-20%
+20% Share of
Primary energy use
renewable energy
vs. BAU* *Business As Usual
What this really
By the year
2020
means
In simple terms, the EU’s targets are aimed at reducing the amount of energy consumed, reducing the use of fossil and other natural mineral fuels used in the production of energy, and the reduction of the amount of greenhouse gases (particularly CO2 and water vapour) produced. And if we are to be successful in doing this, then new regulations, production and performance standards, and energy usage rules will be needed. The EU has not been slow in recognizing this need. New directives have been developed and issued on the subject of
› energy labelling of domestic appliances – this must show the true energy usage of equipment across the whole year: for air-conditioning equipment this includes the introduction of a Seasonal Energy Efficiency Rating (SEER and SCOP)
› energy efficiency in buildings to reduce their impact on the environment through improved insulation, improved heating and lighting systems and the increased use of renewable energy sources
› environmental performance of products throughout their life-cycle by the systematic integration of environmental aspects at a very early stage in the product
design
› fluorinated greenhouse gases (F-gas) and ozone depleting substances which aim to phase out certain refrigerants and tighten up on the checks needed to ensure that such gases are not being leaked into the atmosphere and contributing to the greenhouse effect.
116
Environmental awareness
The Daikin Response Heat pump technology
Daikin, always the leader in air conditioning technology, has embraced the challenges of the EU 20-20-20 declaration and Energy Efficiency Directives and has moved positively to take a market leadership position on many issues.
In many ways, it is with our advanced heat pump technology and heat recovery systems that we can do most to contribute towards the EU’s climate targets. Our use of heat pumps to extract heat from the ambient air (a renewable heat source referred to as aerothermal energy) is very well established and helps reduce the energy usage of whole buildings. In addition, however, heat pumps can be used to extract heat from the ground (geothermal energy) as well as rivers, lakes and ground water (hydrothermal energy). This renewable heat energy is then transferred to the refrigerant system to raise the temperature of the outflow water and thus effectively pre-heat it. This reduces the energy required to provide heating and the transferred heat is often enough to maintain domestic hot water tanks at the correct temperature. This remarkable technology will now be applied to small capacity units as we focus on total climate control in all its forms.
Many years ago, we developed the inverter technology that is now installed in all of our air conditioning units. The inverter system supplies full load power at start up but then monitors the actual heating or cooling demand and steadily reduces the power being used until the correct temperature is reach. It then effectively turns itself off until a change is noted at which point it applies sufficient power to bring the temperature back to the set point. This direct link between temperature control and energy usage means that inverter driven air conditioners are up to 30% more energy efficiency. The eco-design requirements are very ambitious and will in the end ban non-inverter technology.
Temperature / Power input
Heat pump or air conditioner without Inverter
Temperature remains stable
Quick start
Heat pump or air conditioner with Inverter
Set temp.
AEROTHERMAL HEAT PUMP
Time
HYDROTHERMAL HEAT PUMP
GEOTHERMAL HEAT PUMP
Seasonal efficiency
State-of-the-art control systems
Over the years we have been concerned about letting our clients know the true seasonal energy efficiency of our products, as the rating system then in place was misleading. Our vision on this has been vindicated and the introduction of seasonal performance will ensure a better understanding of the energy usage of all air conditioning systems. We have been designing and engineering our equipment to achieve marketleading SEERs and SCOPs and thus contributing to a reduction of energy used.
Our systems are all connected to advanced control systems that give room-by-room settings as well as integrated building control to ensure that the customer can maximise and optimise the use of their Daikin system as a total solution for their building: one that gives perfect climate control, reduced costs and reduced environmental impact.
The way
New refrigerants The regulation on ozone depleting substances and the fluorinated gas directive provide some special challenges. The phasing out of R-22 refrigerants and the concerns over the environmental impact of other refrigerants has led to pressure being brought to bear for the development of non-fluorinated, low GWP (global warming potential) and natural refrigerant gases. This in turn means that refrigerant systems will have to be re-designed and re-engineered – our engineers are already hard at work developing an alternative product line and trying innovative modifications to our current lines. As always, we are the innovation leaders!
forward
All in all, the European Union’s climate concerns have added a new urgency to our ongoing innovation and R&D – we are confident of our response and that it will deliver huge benefits to the customers in terms of more controllable solutions giving perfect comfort, reduced operating costs and a much lower ecological impact.
117
Daikin solutions to R-22 phase out What is R-22 and why is it to be phased-out in Europe? Due to ozone layer depletion, harmful ultraviolet rays reach the surface of the earth giving rise to a number of health and environmental issues. The international community therefore, signed the Montreal Protocol to phase out ozone depletion materials by 2030. The European Union, however, decided to ban R-22 already in 2015.
R-22 is a hydrochlorofluorocarbon (HCFC) which was commonly used in air conditioning systems. When R-22 is released into the air, the ultraviolet rays of the sun cause it to decompose and chlorine is released into the stratosphere. Chlorine reacts with ozone, reducing the amount of the ozone.
When will R-22 be banned in Europe?
2004
2005
2006
Ban of the sale of R-22 air conditioning equipment
1
…
2009
Daikin advises the replacement of your existing R-22 installation
2010
2011
Ban on the use of virgin R-22 for service & maintenance
…
2014
2015
Ban on the use of all R-22 for service & maintenance
Only reclaimed & recycled 1 R-22 allowed
Recycled: re-use of R-22 following a basic cleaning process. Recycled R-22 must be re-used by the same company that carried out the recovery (can be done by installer) Reclaimed: reprocessed R-22 in order to meet the equivalent performance of virgin R-22 (by specialized company)
The Daikin
solution
to upgrade R-22 and R-407C systems
Due to significant developments in heat pump technology, today’s air conditioning systems, running on R-410A refrigerant, offer better performances than R-22 and R-407C systems did in the past. Furthermore, R-22 will be soon unavailable in Europe. Already today, only reclaimed or recycled
R-22 can be used for servicing. To upgrade R-22 and R-407C systems as cost effectively as possible, Daikin units can be installed using existing pipe work. Al large scale of Replacment and Retrofit solutions are offered for Daikin equipment.
What is the impact on an R-22 installation? reclaimed or recycled to cover the demand. As a consequence, supply shortages and price increases are expected. If there is no reclaimed or recycled R-22 available, certain repairs (for example: compressor change) will no longer be possible and considerable air conditioning system downtime can occur.
The R-22 phase out regulation will impact on all currently operating R-22 systems, although reliable R-22 equipment does not need to be replaced immediately because maintenance can be carried out with recycled or reclaimed R-22 until 1st January 2015. However, not enough R-22 is currently
It is therefore worthwhile to consider a replacement system before 2015, especially for air conditioning systems with a large impact on the daily running of the business.
118
The
EWAD~C family
Non-inverter
All year round… Inverter A p p l i e d S y s t e m s C ATA LO G U E 2 0 12
… top efficiency, low sound levels and flexible solutions for a wide range of applications
Applied Systems
Catalogue ■
ALL SEASONS PERFECT C MFORT
Free cooling
The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.
DAIKIN AIRCONDITIONING CENTRAL EUROPE HandelsgmbH campus 21, Europaring F12/402, A – 2345 Brunn/Gebirge Tel.: +43 / 22 36 / 3 25 57-0, Fax: +43 / 22 36 / 3 25 57-900 e-mail: office@daikin.at, www.daikin-ce.com
Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chilling Packages (LCP), Air handling units (AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: www.euroventcertification.com or using: www.certiflash.com
Daikin products are distributed by:
ECPEN12_02_dace_AS • Copyright Daikin We reserve the right for printing errors and model changes.
Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.
2012