IPS
e.max CAD – STEP-BY-STEP FOR CEREC ®
1 2 3 4
®
Preparation
CAD/CAM process Try-in Observe the preparation guidelines and minimum thicknesses for preparation
As a preparation for intra-oral imaging, cover the preparation with IPS Contrast Spray Chairside
CAD/CAM process Mill the restoration from IPS e.max CAD LT
Smooth out the attachment points and finish the restoration. Observe the minimum thickness and contact points.
Try in the restoration in its blue state. Check and adjust the occlusion/articulation, if required.
Fill the restoration with IPS Object Fix Putty and press the IPS e.max CAD Crystallization Pin into the Putty material.
Adapt IPS Object Fix Putty to the pin and crown margin. Avoid contamination of the outer side of the restoration.
Remove any contamination from the outer surface of the crown using a brush dampened in water.
Apply individual characterizations using IPS e.max CAD Crystall./ Shades and Stains.
Spray an even and covering layer of IPS e.max CAD Crystall./ Glaze Spray onto the restoration.
Place the restoration in the center of the IPS e.max CAD Crystallization Tray.
Conduct the Combination firing (Crystall./Glaze) in the Programat CS (Program 1).
After cooling, remove the restoration from the auxiliary firing paste.
Clean the restoration with ultrasound in a water bath.
After crystallization, try in the restoration.
Before final placement, etch the restoration for 20 seconds using IPS Ceramic Etching Gel.
Allow Monobond-S to react for 60 seconds and dry with air.
Clean the preparation, rinse with water and blow dry with air.
Apply Multilink Sprint directly into the restoration.
IPS e.max CAD LT restoration in situ.
Preparation for combination firing*
(Crystallization and Glaze)
Combination firing Cleaning Try-in
Preparation for cementation Placement
* IPS e.max CAD Crystall./Glaze Paste may optionally be used to glaze the restoration. Please refer to the IPS e.max CAD chairside Instructions for Use.
CEREC® is a registered trademark of Sirona Dental Systems GmbH
IPS
e.max CAD ®
Preparation guidelines and minimum thicknesses 1.5
1.5
1.0
0.6
1.5
1.0
1.5
0.6
1.5
1.0
1.5 1.5
1.5
1.5
1.0
0.6
1.2
1.5
0.6
1.5
0.7
Veneers
1.0
1.0
1.2
1.0
6°
0.7
Anterior crowns
Partial crowns
Posterior crowns
Firing parameters for IPS e.max CAD LT in the Programat CS Furnace
P1 IPS e.max CAD Crystall./Glaze
P2 IPS e.max CAD Correction firing
Stand-by temperature
Closing time
Heating rate
Firing temperature
Holding time
Heating rate
Firing temperature
Holding time
Vacuum 1
Vacuum 2
Longterm cooling
Cooling rate
B
S
t1
T1
H1
t2
T2
H2
11 12
21 22
L
tl
403 °C / 757 °F
6:00 min
90 °C/min / 162 °F/min
820 °C / 1508 °F
0:10 min
30 °C/min / 54 °F/min
840 °C / 1544 °F
7:00 min
700 °C / 1292 °F
20 °C/min / 36 °F/min
403 °C / 757 °F
6:00 min
60 °C/min / 108 °F/min
840 °C / 1544 °F
3:00 min
–
–
–
–
–
550/820 °C / 820/840 °C / 1022/1508 °F 1508/1544 °F
450 °C / 842 °F
839 °C / 1542 °F
Cementation IPS e.max CAD Indication Cementation method Etching Conditioning / Silanating Cementation system
Veneers, partial crowns* Adhesive cementation
Anterior and posterior crowns** Adhesive cementation
Self-adhesive cementation
20 sec. with IPS Ceramic Etching Gel Let Monobond-S react for 60 sec. and blow dry Variolink Veneer Variolink II
Variolink II Multilink Automix
Multilink Sprint
* Partial crowns can also be cemented with Multilink Automix. ** Anterior and posterior crowns can also be conventionally cemented using glass ionomer cements (e.g. Vivaglass® CEM) . For that purpose, no silanization with Monobond-S is required.
607618/0707/e/BVD