UW Student Wellness Center
520 ELM DRIVE, MADISON, WI, 53703
GENERAL NOTES
UW-MADISON STUDENT CENTER & WELLNESS CENTER
The Moon House
Cover page
BUILDING
OURDOOR PAVILLION ID4 04/17/2022 Yue Xi Lesley Sager & Jennifer Meyers
Project Number Date Drawn By Checked By
Yue Xi 05/10/2022 DS 623 INTERIOR DESIGN IV
A Scale
5/10/2022 11:56:23 PM
1. The “General Conditions of the Contract for Construction,” AIA Document A201 governs this work, unless noted otherwise (UNO); most stringent requirements prevail. 2. Investigate field conditions and ascertain that work is feasible as shown. Notify the Architect immediately of any problems with field conditions. 3. Examine specified products and submit written exception or objections, or both, with analysis and recommendations prior to submitting bid costs. 4. Submit horizontal bar chart with separate bar for each major trade or operation, identifying first day of each week; shown projected submittal dates for shop drawings, product data and samples, and product delivery dates, including those for Owner-furnished items. 5. Submit subcontractor contact list. 6. Install drywall work in accordance with the current version of the United States Gypsum-Gypsum Construction Handbook, most stringent requirements prevail. 7. Fabricate and install millwork pursuant to the American Woodwork Institute standards, Premium Grade, flush overlay construction with European style (invisible) self-closing, 170-degree opening, heavy duty hinges, and 100 pound rated full extension side mounted drawer slides, UNO 8. Review shop drawings, product data, samples, etc., review stamp and sign prior to submission, submit one large scale reproducible transparency and one print, clearly showing and identifying components and their assembly. Minimum sheet size: 12 x 24 inches; maximum sheet size: 30 x 42 inches. Allow space for the Architect's review stamp. 9. “Typical” means identical for all similar conditions, UNO. 10. “Similar” means comparable characteristics for the conditions noted; verify dimensions and orientations on plans and elevations. 11. “UNO” means unless noted otherwise. 12. “VIF” means verify in the field. 13. “VWA” means verify with the Architect. 14. “Align” means to accurately locate finished faces in the same plane.
THE MOON HOUSE
PARTITION & DOOR PLAN NOTES: 1. Verify partition thickness for internal inclusions, such as plumbing, for correct installation of panels, boxes, etc., verify with the Architect. 2. Immediately analyze Contract Documents and report in writing any inconsistencies discovered therein. 3. Partitions are dimensioned finish-face-to finished-face, UNO. 4. Dimensions are not adjustable without written approval from the Architect. 5. Dimensions to the exterior perimeter window-wall are to the inside face of the finished wall,UNO. 6. Heights are dimensioned from top of slab, UNO.Verify slab conditions. 7. Undercut all doors to clear the top of finished floor, including, but not limited to, carpet, tile, etc., as applicable, by inch maximum, UNO. 8. Prepare doors for hardware specified. 9. Test and adjust doors for smooth, quiet operation. 10. Install water-resistant gypsum board panels in areas exposed to moisture, as required. 11. Provide fire resistive blocking in partitions as required; as applicable, securely anchor all work. 12. Apply fireproofing as required. 13. Glazing tong marks shall not be visible. 14. Clean and polish all glass prior to project delivery. 15. Do not scale off drawings. 16. Protect the building, its systems, finishes and related and appurtenant items so as not to cause damage derived from the work.Comply with building rules and regulations. 17. Caulk gaps where intersection of construction elements is not crisp and consistent, as applicable, UNO. 18. Investigate field conditions for, among other items, asbestos material. notify the owner immediately if asbestos or other hazardous material is found. 19. Price, provide and install all items. Price labor required for a complete installation of a system or assembly, such as required structure, bracing, access panels, junction boxes, items called for in the Manufacturer’s literature, etc. 20. Where new work ties in with existing work, verify extent, finish and location of existing work as related to new construction to ensure proper finish continuity, alignment, and feasibility of intent shown on drawings. 1
2
3
7' - 1"
4
11' - 7"
5
12' - 0"
102' - 4"
12' - 0"
DOOR SINGLE FLUSH 36" x 84"
A
5" GWB 1HR RATING B
DOOR EXTERIOR SINGLE LITE 36" x 84" 8" PLUMBING WALL 8" GWB 2HR RATING 8" GWB EXTERIOR WALL
DOOR INSWING FRENCH TOP 72" x 84"
C
Partition legend 1 1/4" = 1'-0"
D
DOOR EXTERIOR DOUBEL 96" x 84"
E
DOOR SINGLE BARN STYLE 96" x 84"
F
DOOR DOUBLE FLUSH PANEL 72" X 84"
0'
4'
8'
16'
Door legend 1 1/4" = 1'-0"
UW Student Wellness Center
7
6
12' - 1"
2'
8
12' - 1"
9
12' - 1"
12' - 0"
11' - 5"
8' - 7"
6' - 0"
A 7' - 5"
A
82 SF C
B
12' - 3"
A
A
A
A
A
Gender neutral bathroom
6' - 5"
Janitor's closet
Retail space
118 SF
401 SF
3' - 9"
3' - 6"
3' - 7"
5' - 8"
11' - 3"
A
9' - 11"
The Moon House
B E
UP 10' - 6"
6' - 0"
1339 SF
23' - 8"
49' - 9"
Wellness cafe
D
9' - 2" Lobby
11' - 0"
810 SF
23' - 9" A
3' - 0"
C
Social lounge
egress
254 SF
707 SF F Project Number Date
11' - 4"
D
Drawn By Checked By
1
Level 1 partition 1/4" = 1'-0"
ID4 04/17/2022 Author Checker
AA101.1 Scale
1/4" = 1'-0"
5/10/2022 11:56:28 PM
162 SF
11' - 10"
Kitchen & staff
9' - 5"
14' - 10"
11' - 11"
Partition plan level 1
PARTITION & DOOR PLAN NOTES: 1. Verify partition thickness for internal inclusions, such as plumbing, for correct installation of panels, boxes, etc., verify with the Architect. 2. Immediately analyze Contract Documents and report in writing any inconsistencies discovered therein. 3. Partitions are dimensioned finish-face-to finished-face, UNO. 4. Dimensions are not adjustable without written approval from the Architect. 5. Dimensions to the exterior perimeter window-wall are to the inside face of the finished wall,UNO. 6. Heights are dimensioned from top of slab, UNO.Verify slab conditions. 7. Undercut all doors to clear the top of finished floor, including, but not limited to, carpet, tile, etc., as applicable, by inch maximum, UNO. 8. Prepare doors for hardware specified. 9. Test and adjust doors for smooth, quiet operation. 10. Install water-resistant gypsum board panels in areas exposed to moisture, as required. 11. Provide fire resistive blocking in partitions as required; as applicable, securely anchor all work. 12. Apply fireproofing as required. 13. Glazing tong marks shall not be visible. 14. Clean and polish all glass prior to project delivery. 15. Do not scale off drawings. 16. Protect the building, its systems, finishes and related and appurtenant items so as not to cause damage derived from the work.Comply with building rules and regulations. 17. Caulk gaps where intersection of construction elements is not crisp and consistent, as applicable, UNO. 18. Investigate field conditions for, among other items, asbestos material. notify the owner immediately if asbestos or other hazardous material is found. 19. Price, provide and install all items. Price labor required for a complete installation of a system or assembly, such as required structure, bracing, access panels, junction boxes, items called for in the Manufacturer’s literature, etc. 20. Where new work ties in with existing work, verify extent, finish and location of existing work as related to new construction to ensure proper finish continuity, alignment, and feasibility of intent shown on drawings. 1
2
3
7' - 7"
4
11' - 1"
5" GWB 1HR RATING A
8" PLUMBING WALL 8" GWB 2HR RATING B
8" GWB EXTERIOR WALL Partition legend 2 1/4" = 1'-0"
0'
2'
4'
8'
16'
UW Student Wellness Center
102' - 4"
12' - 0"
DOOR EXTERIOR SINGLE LITE 36" x 84"
Door legend 2 1/4" = 1'-0"
5
12' - 0"
DOOR SINGLE FLUSH 36" x 84"
7
6
12' - 1"
12' - 1"
8
9
12' - 1"
12' - 0"
11' - 5"
13' - 0"
Therapy room
10' - 5"
10' - 10"
Therapy room
Therapy room
Therapy room
Private office
Private office
135 SF
144 SF
144 SF
125 SF
126 SF
15' - 6"
23' - 2"
Resource room
Open office
187 SF
281 SF
123 SF
A
6' - 1"
A
A
A
A
A
A
5' - 10"
18' - 7"
A
A
A
9' - 2"
The Moon House
A
11' - 5"
B 4' - 4"
3' - 9"
6' - 10"
9' - 11"
6' - 0" A
9' - 0"
64 SF
6' - 5" A
A
15' - 5"
A
6' - 9"
2' - 10" Pet intake room
9' - 5"
14' - 10"
16' - 10" A
1' - 0"
4' - 5"
11' - 9"
C
A
6' - 9"
65 SF A
B
GenderA neutral bathroom
493 SF
157 SF
Egress
Study space
213 SF
600 SF
Partition plan level 2
Presentation room
321 SF Project Number Date Drawn By
11' - 9" 11' - 4"
18' - 2"
Checked By
ID4 04/17/2022 Author Checker
AA101.2
D
1
Level 2 partition 1/4" = 1'-0"
Scale
1/4" = 1'-0"
5/10/2022 11:56:48 PM
9' - 1"
10' - 4"
95 SF
Community share zone
4' - 9"
94 SF
ADA bathroom
5' - 8"
Therapy room
4' - 11"
11' - 11"
49' - 9"
Therapy room
UP
9' - 7"
3' - 9"
5' - 9"
3' - 7"
PARTITION & DOOR PLAN NOTES: 1. Verify partition thickness for internal inclusions, such as plumbing, for correct installation of panels, boxes, etc., verify with the Architect. 2. Immediately analyze Contract Documents and report in writing any inconsistencies discovered therein. 3. Partitions are dimensioned finish-face-to finished-face, UNO. 4. Dimensions are not adjustable without written approval from the Architect. 5. Dimensions to the exterior perimeter window-wall are to the inside face of the finished wall,UNO. 6. Heights are dimensioned from top of slab, UNO.Verify slab conditions. 7. Undercut all doors to clear the top of finished floor, including, but not limited to, carpet, tile, etc., as applicable, by inch maximum, UNO. 8. Prepare doors for hardware specified. 9. Test and adjust doors for smooth, quiet operation. 10. Install water-resistant gypsum board panels in areas exposed to moisture, as required. 11. Provide fire resistive blocking in partitions as required; as applicable, securely anchor all work. 12. Apply fireproofing as required. 13. Glazing tong marks shall not be visible. 14. Clean and polish all glass prior to project delivery. 15. Do not scale off drawings. 16. Protect the building, its systems, finishes and related and appurtenant items so as not to cause damage derived from the work.Comply with building rules and regulations. 17. Caulk gaps where intersection of construction elements is not crisp and consistent, as applicable, UNO. 18. Investigate field conditions for, among other items, asbestos material. notify the owner immediately if asbestos or other hazardous material is found. 19. Price, provide and install all items. Price labor required for a complete installation of a system or assembly, such as required structure, bracing, access panels, junction boxes, items called for in the Manufacturer’s literature, etc. 20. Where new work ties in with existing work, verify extent, finish and location of existing work as related to new construction to ensure proper finish continuity, alignment, and feasibility of intent shown on drawings. 1
2
3
7' - 7"
4
11' - 1"
5
12' - 0"
A
5" GWB 1HR RATING G
DOOR FRENCH WINE DOOR 48" x 84" 8" PLUMBING WALL 8" GWB 2HR RATING 8" GWB EXTERIOR WALL
Door legend 3 1/4" = 1'-0"
Partition legend 2 1/4" = 1'-0"
0'
102' - 4"
12' - 0"
DOOR SINGLE FLUSH 36" x 84"
7
6
12' - 1"
12' - 1"
2'
8
4'
8'
16'
UW Student Wellness Center
9
12' - 1"
12' - 4"
11' - 2"
A
Audience
Bar area
Prep room
844 SF
164 SF
18' - 0"
18' - 8"
G
899 SF
The Moon House
Stage
A
183 SF
18' - 1"
A
13' - 8"
7' - 3"
7' - 10"
A
9' - 6"
25' - 0"
11' - 0"
375 SF A
A
26' - 10"
1' - 0"
C
Community share zone
152 SF
Flexible event / training room
Flexible event / training room
355 SF
373 SF
15' - 0"
9' - 5"
14' - 5"
Backstage
Partition plan level 3
6' - 5"
A
Project Number Date
11' - 5"
D
1
Level 3 partition 1/4" = 1'-0"
Drawn By Checked By
ID4 04/17/2022 Author Checker
AA101.3 Scale
1/4" = 1'-0"
5/10/2022 11:57:07 PM
71 SF
16' - 9"
66 SF
10' - 8"
ADA bathroom
3' - 7"
10' - 4"
ADA bathroom
16' - 8"
49' - 9"
B
REFLECTED CEILING PLAN NOTES
COMPOUND CELING GWB ON METAL STUDS 9' AFF
XAL MENO CEILING MOUNTED LIGHT 9" AFF
1. Provide appropriate clearances for fixtures, ducts, and related plenum items necessary to maintain the specified finish ceiling height above the finish floor slab. 2. Install switches 38” inches above finish floor slab, UNO; verify floor slab conditions; heights are determined from top of floor slab to centerline of cover plate, mounted vertically lengthwise, UNO; gang switched cover plates shall be one-piece type, quantity of switches as applicable. 3. Architectural drawing determines the location of luminaires and supersedes all others, UNO. 4. Submit grille, sprinkler, thermostat, and other elements layout to the Architect for review prior to installation. 5. Verify field conditions and locations of all plumbing, mechanical ducts, structural elements, and all other applicable items; install applicable new plumbing, mechanical fans, ducts, conduits, and other related and appurtenant items so as not to conflict with luminaires and all field conditions.Contractor is responsible for coordination of plenum elements. 6. Verify location of thermostats with the Architect. 7. Install Underwriters Laboratories, Inc. (UL) labeled devices. 8. Install warm-white LED lamps throughout, as applicable,UNO. 9. Finished acoustical tile ceiling height is 9’-0” above existing floor slab on floors 1, 3, and 4 UNO. 10. Install recessed down lighting luminaires and other fixtures on center of ceiling tiles, UNO; verify related conditions. 11. Install sprinkler heads on the center of ceiling tile, UNO; field verify related conditions. All locations conform to NFPA 13; VIF. 12. Install fully recessed fixtures, including but not limited to diffusers, grilles, etc., UNO.
ACT SYSTEM 2' X 2' 9' AFF
PUREEDGE REVEAL LINEAR RECESSED LIGHT 9" AFF
ARMSTRONG CEILING PANELS WOODWORKS GRILLE 9' AFF
INTRA PENDANT CURVE LIGHT 9" AFF
MUUTO AMBIT PENDANT LIGHT 9" AFF MUUTO STRAND PENDANT LIGHT 9" AFF PUREEDGE PIX STICKS DOWNLIGHT 9" AFF
LINDER CEILING PANELS BAFFLES 9' AFF
AMORPHICON SUSPENDED LIGHT 9" AFF
Ceiling & light legend 1 3/8" = 1'-0"
1
2
3
0'
4
5
6
7
8
2'
4'
8'
UW Student Wellness Center
16'
9
A
The Moon House B
C
Project Number Date Drawn By Checked By
D
1
Level 1 RCP 1/4" = 1'-0"
ID4 04/17/2022 Author Checker
AA102.1 Scale
As indicated
5/10/2022 11:57:16 PM
RCP level 1
REFLECTED CEILING PLAN NOTES COMPOUND CELING GWB ON METAL STUDS 9' AFF
XAL MENO CEILING MOUNTED LIGHT ROUND 9" AFF
ACT SYSTEM 2' X 2' 9' AFF
XAL LENO CEILING MOUNTED LIGHT LINEAR 9" AFF PUREEDGE PIX STICKS DOWNLIGHT 9" AFF
0'
2'
4'
8'
16'
LUMENWERD ELIA ROUND LIGHT 9" AFF
EUREKA CEL 306S 9" AFF Ceiling & light legend 2 1/2" = 1'-0"
1
2
3
4
5
6
1. Provide appropriate clearances for fixtures, ducts, and related plenum items necessary to maintain the specified finish ceiling height above the finish floor slab. 2. Install switches 38” inches above finish floor slab, UNO; verify floor slab conditions; heights are determined from top of floor slab to centerline of cover plate, mounted vertically lengthwise, UNO; gang switched cover plates shall be one-piece type, quantity of switches as applicable. 3. Architectural drawing determines the location of luminaires and supersedes all others, UNO. 4. Submit grille, sprinkler, thermostat, and other elements layout to the Architect for review prior to installation. 5. Verify field conditions and locations of all plumbing, mechanical ducts, structural elements, and all other applicable items; install applicable new plumbing, mechanical fans, ducts, conduits, and other related and appurtenant items so as not to conflict with luminaires and all field conditions.Contractor is responsible for coordination of plenum elements. 6. Verify location of thermostats with the Architect. 7. Install Underwriters Laboratories, Inc. (UL) labeled devices. 8. Install warm-white LED lamps throughout, as applicable,UNO. 9. Finished acoustical tile ceiling height is 9’-0” above existing floor slab on floors 1, 3, and 4 UNO. 10. Install recessed down lighting luminaires and other fixtures on center of ceiling tiles, UNO; verify related conditions. 11. Install sprinkler heads on the center of ceiling tile, UNO; field verify related conditions. All locations conform to NFPA 13; VIF. 12. Install fully recessed fixtures, including but not limited to diffusers, grilles, etc., UNO. 7
8
UW Student Wellness Center
9
A
The Moon House B
C
Project Number Date Drawn By Checked By
D 1
ID4 04/17/2022 Author Checker
AA102.2
Level 2 RCP 1/4" = 1'-0" Scale
As indicated
5/10/2022 11:57:27 PM
RCP level 2
1' - 1" 3' - 1"
3' - 11"
3' - 10"
3' - 10"
MAPLE WOOD SHELF 0' - 1"
9' - 0"
4' - 0"
2' - 0"
4' - 1"
3' - 8"
2' - 0"
1' - 8"
WHITE CERAMIC CEILING DECO MAPLE HIGH WOOD SHELF
4' - 5"
0' - 7"
5' - 1"
0' - 7"
2' - 0"
0' - 6"
2' - 0"
0' - 5"
2' - 8"
0' - 2"
0' - 1"
2' - 8"
WHITE CERAMIC CAFE ISLAND 0' - 4"
3' - 2"
GREY QUARTZ COUNTERTOP
1
UW Student Wellness Center
MAPLE ISLAND BASE 0' - 0' 2"- 4"
19' - 9"
Cafe elevation 1 1" = 1'-0"
3' - 11"
WHITE CERAMIC CEILING DECO
MAPLE WOOD SHELF
0' - 10"
MAPLE HIGH WOOD SHELF
2' - 8"
0' - 2"
GREY QUARTZ COUNTERTOP
WHITE CERAMIC CAFE ISLAND MAPLE ISLAND BASE 6' - 0"
2
Cafe elevation 2 1" = 1'-0"
2' - 0"
1. The “General Conditions of the Contract for Construction,” AIA Document A201 governs this work, unless noted otherwise (UNO); most stringent requirements prevail. 2. Investigate field conditions and ascertain that work is feasible as shown. Notify the Architect immediately of any problems with field conditions. 3. Examine specified products and submit written exception or objections, or both, with analysis and recommendations prior to submitting bid costs. 4. Submit horizontal bar chart with separate bar for each major trade or operation, identifying first day of each week; shown projected submittal dates for shop drawings, product data and samples, and product delivery dates, including those for Owner-furnished items. 5. Submit subcontractor contact list. 6. Install drywall work in accordance with the current version of the United States Gypsum-Gypsum Construction Handbook, most stringent requirements prevail. 7. Fabricate and install millwork pursuant to the American Woodwork Institute standards, Premium Grade, flush overlay construction with European style (invisible) self-closing, 170-degree opening, heavy duty hinges, and 100 pound rated full extension side mounted drawer slides, UNO 8. Review shop drawings, product data, samples, etc., review stamp and sign prior to submission, submit one large scale reproducible transparency and one print, clearly showing and identifying components and their assembly. Minimum sheet size: 12 x 24 inches; maximum sheet size: 30 x 42 inches. Allow space for the Architect's review stamp. 9. “Typical” means identical for all similar conditions, UNO. 10. “Similar” means comparable characteristics for the conditions noted; verify dimensions and orientations on plans and elevations. 11. “UNO” means unless noted otherwise. 12. “VIF” means verify in the field. 13. “VWA” means verify with the Architect. 14. “Align” means to accurately locate finished faces in the same plane.
The Moon House
Elevation cafe
Project Number Date Drawn By Checked By
ID4 04/17/2022 Author Checker
AA201.1 Scale
1" = 1'-0"
5/10/2022 11:57:28 PM
1' - 1"
GENERAL NOTES
GENERAL NOTES
BLACK&BLUE QUARTZ COUNTERTOP
BRASS FOOTREST
0' - 1"
0' - 2"
UW Student Wellness Center
Bar counter elevation 1 1" = 1'-0"
0' - 1" 1' - 0" 0' - 1" 1' - 0" 0' - 1" 1' - 0" 0' - 1"
0' - 1"
BLACK LAMINATE WINE SHELF
0' - 1"
3' - 8"
1' - 5"
4' - 11"
The Moon House
BLACK&BLUE QUARTZ COUNTERTOP
Elevation architectural
0' - 2" 0' - 1"
3' - 0"
0' - 1"
4' - 8"
0' - 1"
3' - 0"
BLUE GLOSSY PAINT ISLAND
0' - 1"
Project Number
3
Bar wall elevation 1 1" = 1'-0"
2
0' - 1"
0' - 2"
BRASS FOOTREST
Bar counter elevation 2 1" = 1'-0"
Date Drawn By Checked By
ID4 04/17/2022 Author Checker
AA201.2 Scale
1" = 1'-0"
5/10/2022 11:57:29 PM
3' - 2"
11' - 1"
3' - 2"
1
17' - 7"
10' - 8"
0' - 2"
3' - 2"
0' - 2"
BLUE GLOSSY PAINT ISLAND
1. The “General Conditions of the Contract for Construction,” AIA Document A201 governs this work, unless noted otherwise (UNO); most stringent requirements prevail. 2. Investigate field conditions and ascertain that work is feasible as shown. Notify the Architect immediately of any problems with field conditions. 3. Examine specified products and submit written exception or objections, or both, with analysis and recommendations prior to submitting bid costs. 4. Submit horizontal bar chart with separate bar for each major trade or operation, identifying first day of each week; shown projected submittal dates for shop drawings, product data and samples, and product delivery dates, including those for Owner-furnished items. 5. Submit subcontractor contact list. 6. Install drywall work in accordance with the current version of the United States Gypsum-Gypsum Construction Handbook, most stringent requirements prevail. 7. Fabricate and install millwork pursuant to the American Woodwork Institute standards, Premium Grade, flush overlay construction with European style (invisible) self-closing, 170-degree opening, heavy duty hinges, and 100 pound rated full extension side mounted drawer slides, UNO 8. Review shop drawings, product data, samples, etc., review stamp and sign prior to submission, submit one large scale reproducible transparency and one print, clearly showing and identifying components and their assembly. Minimum sheet size: 12 x 24 inches; maximum sheet size: 30 x 42 inches. Allow space for the Architect's review stamp. 9. “Typical” means identical for all similar conditions, UNO. 10. “Similar” means comparable characteristics for the conditions noted; verify dimensions and orientations on plans and elevations. 11. “UNO” means unless noted otherwise. 12. “VIF” means verify in the field. 13. “VWA” means verify with the Architect. 14. “Align” means to accurately locate finished faces in the same plane.
WHITE GYPSUM COLUMN
1IN X 1IN WOOD STRIP DECO INCREASING 4IN SPACED 7IN FROM EACH OTHER
9' - 0"
BLACK LAMINATE LOGO
CUSTOMIZED SPHERICAL LIGHT
UW Student Wellness Center
1' - 0" 6' - 0"
Entry elevation 1 1" = 1'-0"
GENERAL NOTES
WHITE GYPSUM COLUMN 1IN X 1IN WOOD STRIP DECO INCREASING 4IN SPACED 7IN FROM EACH OTHER
CUSTOMIZED SPHERICAL LIGHT
BLACK LAMINATE LOGO 1' - 0" 0' - 1" 6' - 0"
2
Entry elevation 2 1" = 1'-0"
1. The “General Conditions of the Contract for Construction,” AIA Document A201 governs this work, unless noted otherwise (UNO); most stringent requirements prevail. 2. Investigate field conditions and ascertain that work is feasible as shown. Notify the Architect immediately of any problems with field conditions. 3. Examine specified products and submit written exception or objections, or both, with analysis and recommendations prior to submitting bid costs. 4. Submit horizontal bar chart with separate bar for each major trade or operation, identifying first day of each week; shown projected submittal dates for shop drawings, product data and samples, and product delivery dates, including those for Owner-furnished items. 5. Submit subcontractor contact list. 6. Install drywall work in accordance with the current version of the United States Gypsum-Gypsum Construction Handbook, most stringent requirements prevail. 7. Fabricate and install millwork pursuant to the American Woodwork Institute standards, Premium Grade, flush overlay construction with European style (invisible) self-closing, 170-degree opening, heavy duty hinges, and 100 pound rated full extension side mounted drawer slides, UNO 8. Review shop drawings, product data, samples, etc., review stamp and sign prior to submission, submit one large scale reproducible transparency and one print, clearly showing and identifying components and their assembly. Minimum sheet size: 12 x 24 inches; maximum sheet size: 30 x 42 inches. Allow space for the Architect's review stamp. 9. “Typical” means identical for all similar conditions, UNO. 10. “Similar” means comparable characteristics for the conditions noted; verify dimensions and orientations on plans and elevations. 11. “UNO” means unless noted otherwise. 12. “VIF” means verify in the field. 13. “VWA” means verify with the Architect. 14. “Align” means to accurately locate finished faces in the same plane.
The Moon House
Elevation architectural Project Number Date Drawn By Checked By
ID4 04/17/2022 Author Checker
AA201.3 Scale
1" = 1'-0"
5/10/2022 11:57:30 PM
1
0' - 8" 0' - 10"
0' - 10" 1' - 5"
GENERAL NOTES
BUILT-IN HEMP ROPE SEATING WITH HOLES
BUILT-IN HEMP ROPE SEATING WITH HOLES
3' - 8"
0' - 2"
1' - 6"
2' - 11"
1' - 0"
WHITE LAMINATE SHELF FOR PET INTERACTION
0'
-7 "
0' - 2"
0' - 4"
2' - 0"
R
2' - 2"
1' - 0"
3' - 7"
7' - 0" 10' - 6"
1
Pet wall elevation 1 1" = 1'-0"
0' - 4" 0' - 4" 0' - 4" 0' - 4"
7' - 0"
BUILT-IN BLACK LAMINATE RECORDS DISPLAY
1' - 2"
1' - 3"
BLACK LAMINATE SHELF
BUILT-IN BLACK LAMINATE RECORDS DISPLAY
0' - 4" 0' - 4" 0' - 4" 0' - 4"
1' - 2"
1' - 3"
BLACK LAMINATE SHELF
2' - 0"
0' - 1" 0' - 7" 0' - 7" 0' - 7" 0' - 7" 2' - 0"
7' - 0"
Pet wall elevation 2 1" = 1'-0"
1' - 3"
1' - 3"
2
0' - 7" 0' - 7" 0' - 7" 0' - 1"
10' - 0" 5' - 6"
2' - 0" 10' - 0"
2' - 6"
1. The “General Conditions of the Contract for Construction,” AIA Document A201 governs this work, unless noted otherwise (UNO); most stringent requirements prevail. 2. Investigate field conditions and ascertain that work is feasible as shown. Notify the Architect immediately of any problems with field conditions. 3. Examine specified products and submit written exception or objections, or both, with analysis and recommendations prior to submitting bid costs. 4. Submit horizontal bar chart with separate bar for each major trade or operation, identifying first day of each week; shown projected submittal dates for shop drawings, product data and samples, and product delivery dates, including those for Owner-furnished items. 5. Submit subcontractor contact list. 6. Install drywall work in accordance with the current version of the United States GypsumGypsum Construction Handbook, most stringent requirements prevail. 7. Fabricate and install millwork pursuant to the American Woodwork Institute standards, Premium Grade, flush overlay construction with European style (invisible) self-closing, 170degree opening, heavy duty hinges, and 100 pound rated full extension side mounted drawer slides, UNO 8. Review shop drawings, product data, samples, etc., review stamp and sign prior to submission, submit one large scale reproducible transparency and one print, clearly showing and identifying components and their assembly. Minimum sheet size: 12 x 24 inches; maximum sheet size: 30 x 42 inches. Allow space for the Architect's review stamp. 9. “Typical” means identical for all similar conditions, UNO. 10. “Similar” means comparable characteristics for the conditions noted; verify dimensions and orientations on plans and elevations. 11. “UNO” means unless noted otherwise. 12. “VIF” means verify in the field. 13. “VWA” means verify with the Architect. 14. “Align” means to accurately locate finished faces in the same plane.
UW Student Wellness Center
The Moon House
Elevation room & corridor Project Number Date Drawn By
Retail elevation 1 3 1" = 1'-0"
Retail elevation 2 4 1" = 1'-0"
Checked By
ID4 04/17/2022 Author Checker
AA201.4 Scale
1" = 1'-0"
5/10/2022 11:57:31 PM
9' - 0"
1' - 2"
0' - 11"
0' - 9"
0' - 7" 0' - 6" 0' - 5"0' - 4"0' - 6" 0' - 6" 0' - 6" 0' - 6" 0' - 4"
0' - 9"
0' - 10"
0' - 10"
0' - 9"
0' - 8" 1' - 0" 1' - 0"
4' - 7" 1' - 1"
9' - 0"
WHITE LAMINATE SHELF FOR PET INTERACTION
0' - 11"
UW Student Wellness Center
The Moon House
Project Number Date Drawn By Checked By
ID4 04/17/2022 Author Checker
AA601.1 Scale
5/10/2022 11:57:31 PM
furniture schedule
UW Student Wellness Center
The Moon House
Project Number Date Drawn By Checked By
ID4 04/17/2022 Author Checker
AA601.2 Scale
5/10/2022 11:57:32 PM
furniture schedule
UW Student Wellness Center
The Moon House
Project Number Date Drawn By Checked By
ID4 04/17/2022 Author Checker
AA601.3 Scale
5/10/2022 11:57:32 PM
furniture schedule
UW Student Wellness Center
The Moon House
Project Number Date Drawn By Checked By
ID4 04/17/2022 Author Checker
AA601.4 Scale
5/10/2022 11:57:32 PM
furniture schedule
Janitor's closet
Gender neutral bathroom
118 SF
82 SF
Retail space
401 SF
UP
Lobby
810 SF
Wellness cafe
UW Student Wellness Center
1339 SF
Social lounge
707 SF Kitchen & staff
162 SF
Level 1 furniture 1/4" = 1'-0"
GENERAL NOTES 1. The “General Conditions of the Contract for Construction,” AIA Document A201 governs this work, unless noted otherwise (UNO); most stringent requirements prevail. 2. Investigate field conditions and ascertain that work is feasible as shown. Notify the Architect immediately of any problems with field conditions. 3. Examine specified products and submit written exception or objections, or both, with analysis and recommendations prior to submitting bid costs. 4. Submit horizontal bar chart with separate bar for each major trade or operation, identifying first day of each week; shown projected submittal dates for shop drawings, product data and samples, and product delivery dates, including those for Owner-furnished items. 5. Submit subcontractor contact list. 6. Install drywall work in accordance with the current version of the United States Gypsum-Gypsum Construction Handbook, most stringent requirements prevail. 7. Fabricate and install millwork pursuant to the American Woodwork Institute standards, Premium Grade, flush overlay construction with European style (invisible) self-closing, 170-degree opening, heavy duty hinges, and 100 pound rated full extension side mounted drawer slides, UNO 8. Review shop drawings, product data, samples, etc., review stamp and sign prior to submission, submit one large scale reproducible transparency and one print, clearly showing and identifying components and their assembly. Minimum sheet size: 12 x 24 inches; maximum sheet size: 30 x 42 inches. Allow space for the Architect's review stamp. 9. “Typical” means identical for all similar conditions, UNO. 10. “Similar” means comparable characteristics for the conditions noted; verify dimensions and orientations on plans and elevations. 11. “UNO” means unless noted otherwise. 12. “VIF” means verify in the field. 13. “VWA” means verify with the Architect. 14. “Align” means to accurately locate finished faces in the same plane.
0'
2'
4'
8'
The Moon House
16'
Furniture level 1
Project Number Date Drawn By Checked By
ID4 04/17/2022 Author Checker
AI101.1 Scale
1/4" = 1'-0"
5/10/2022 11:57:52 PM
1
Therapy room
Therapy room
135 SF
144 SF
Therapy room
144 SF
Private office
Private office
Resource room
Open office
125 SF
126 SF
187 SF
281 SF
GNHPF.
GNHPF. CA03
CA03
GNHPF.
CA06
CA10
GNHPF.
Therapy room
123 SF
UP
Therapy room
Therapy room
94 SF
95 SF
Gender neutral bathroom
ADA bathroom
Community share zone
64 SF
493 SF
UW Student Wellness Center
65 SF
Pet intake room
157 SF Egress
213 SF
1
Study space
Presentation room
321 SF
600 SF
The Moon House
Level 2 furniture 1/4" = 1'-0" 0'
2'
4'
8'
16'
GENERAL NOTES
Furniture level 2
Project Number Date Drawn By Checked By
ID4 04/17/2022 Author Checker
AI101.2 Scale
1/4" = 1'-0"
5/10/2022 11:58:28 PM
1. The “General Conditions of the Contract for Construction,” AIA Document A201 governs this work, unless noted otherwise (UNO); most stringent requirements prevail. 2. Investigate field conditions and ascertain that work is feasible as shown. Notify the Architect immediately of any problems with field conditions. 3. Examine specified products and submit written exception or objections, or both, with analysis and recommendations prior to submitting bid costs. 4. Submit horizontal bar chart with separate bar for each major trade or operation, identifying first day of each week; shown projected submittal dates for shop drawings, product data and samples, and product delivery dates, including those for Owner-furnished items. 5. Submit subcontractor contact list. 6. Install drywall work in accordance with the current version of the United States Gypsum-Gypsum Construction Handbook, most stringent requirements prevail. 7. Fabricate and install millwork pursuant to the American Woodwork Institute standards, Premium Grade, flush overlay construction with European style (invisible) self-closing, 170-degree opening, heavy duty hinges, and 100 pound rated full extension side mounted drawer slides, UNO 8. Review shop drawings, product data, samples, etc., review stamp and sign prior to submission, submit one large scale reproducible transparency and one print, clearly showing and identifying components and their assembly. Minimum sheet size: 12 x 24 inches; maximum sheet size: 30 x 42 inches. Allow space for the Architect's review stamp. 9. “Typical” means identical for all similar conditions, UNO. 10. “Similar” means comparable characteristics for the conditions noted; verify dimensions and orientations on plans and elevations. 11. “UNO” means unless noted otherwise. 12. “VIF” means verify in the field. 13. “VWA” means verify with the Architect. 14. “Align” means to accurately locate finished faces in the same plane.
Prep room
164 SF
Audience
899 SF
Bar area
844 SF
ADA bathroom
ADA bathroom
66 SF
71 SF
Community share zone
375 SF
UW Student Wellness Center
Stage
183 SF
Backstage
Flexible event / training room
Flexible event / training room
152 SF
355 SF
373 SF
36/72
36/72
36/72
Level 3 furniture 1/4" = 1'-0"
GENERAL NOTES 1. The “General Conditions of the Contract for Construction,” AIA Document A201 governs this work, unless noted otherwise (UNO); most stringent requirements prevail. 2. Investigate field conditions and ascertain that work is feasible as shown. Notify the Architect immediately of any problems with field conditions. 3. Examine specified products and submit written exception or objections, or both, with analysis and recommendations prior to submitting bid costs. 4. Submit horizontal bar chart with separate bar for each major trade or operation, identifying first day of each week; shown projected submittal dates for shop drawings, product data and samples, and product delivery dates, including those for Owner-furnished items. 5. Submit subcontractor contact list. 6. Install drywall work in accordance with the current version of the United States Gypsum-Gypsum Construction Handbook, most stringent requirements prevail. 7. Fabricate and install millwork pursuant to the American Woodwork Institute standards, Premium Grade, flush overlay construction with European style (invisible) self-closing, 170-degree opening, heavy duty hinges, and 100 pound rated full extension side mounted drawer slides, UNO 8. Review shop drawings, product data, samples, etc., review stamp and sign prior to submission, submit one large scale reproducible transparency and one print, clearly showing and identifying components and their assembly. Minimum sheet size: 12 x 24 inches; maximum sheet size: 30 x 42 inches. Allow space for the Architect's review stamp. 9. “Typical” means identical for all similar conditions, UNO. 10. “Similar” means comparable characteristics for the conditions noted; verify dimensions and orientations on plans and elevations. 11. “UNO” means unless noted otherwise. 12. “VIF” means verify in the field. 13. “VWA” means verify with the Architect. 14. “Align” means to accurately locate finished faces in the same plane.
The Moon House 0'
2'
4'
8'
16'
Furniture level 3
Project Number Date Drawn By Checked By
ID4 04/17/2022 Author Checker
AI101.3 Scale
1/4" = 1'-0"
5/10/2022 11:59:06 PM
1
36/72
F4
W1
A
A
F2
W6
Gender neutral bathroom
Janitor's closet
A
82 SF
A
A
A
118 SF
C
W5
Retail space
F3
401 SF
F2 B
A
W1 F2
F2
F2
F2
Wellness cafe
E
UP
1339 SF F1
W1
W3
D
F4
W2
W2
F4
UW Student Wellness Center
Lobby
810 SF
A
Kitchen & staff
F3
Social lounge
W1
162 SF
1
W2
707 SF egress
F3
F1
W1
F
254 SF
Level 1 finish 1/4" = 1'-0"
The Moon House
GENERAL NOTES F1
OAK WOOD FLOORING
W1
WHITE PAINT
F2
WHITE GLOSSY BATHROOM TILE
W2
CREAM TEXTURED WALLPAPER
F3
GREY CONCRETE FLOORING
W3
LIGHT BLUE CONSTELLATION WALLPAPER
F4
WOOD LOOK LVT
W4
BLUE GALAXY THEME WALLPAPER
F5
DEEP BLUE CARPET TILE
W5
BLACK & WHITE GALAXY THEME WALLPAPER
F6
LIGHT GREY CARPET TILE
W6
LIGHT BLUE GLOSSY BATHROOM TILE
F7
BLUE & GREY CARPET TILE
B1
GREY PAINT WALL BASE
Floor & wall finish 1
floor & wall finish legend 1/4" = 1'-0"
Project Number
Date Drawn By Checked By
0'
2'
4'
8'
ID4 04/17/2022 Author Checker
AI102.1
16' Scale
1/4" = 1'-0"
5/10/2022 11:59:09 PM
1. The “General Conditions of the Contract for Construction,” AIA Document A201 governs this work, unless noted otherwise (UNO); most stringent requirements prevail. 2. Investigate field conditions and ascertain that work is feasible as shown. Notify the Architect immediately of any problems with field conditions. 3. Examine specified products and submit written exception or objections, or both, with analysis and recommendations prior to submitting bid costs. 4. Submit horizontal bar chart with separate bar for each major trade or operation, identifying first day of each week; shown projected submittal dates for shop drawings, product data and samples, and product delivery dates, including those for Owner-furnished items. 5. Submit subcontractor contact list. 6. Install drywall work in accordance with the current version of the United States Gypsum-Gypsum Construction Handbook, most stringent requirements prevail. 7. Fabricate and install millwork pursuant to the American Woodwork Institute standards, Premium Grade, flush overlay construction with European style (invisible) self-closing, 170-degree opening, heavy duty hinges, and 100 pound rated full extension side mounted drawer slides, UNO 8. Review shop drawings, product data, samples, etc., review stamp and sign prior to submission, submit one large scale reproducible transparency and one print, clearly showing and identifying components and their assembly. Minimum sheet size: 12 x 24 inches; maximum sheet size: 30 x 42 inches. Allow space for the Architect's review stamp. 9. “Typical” means identical for all similar conditions, UNO. 10. “Similar” means comparable characteristics for the conditions noted; verify dimensions and orientations on plans and elevations. 11. “UNO” means unless noted otherwise. 12. “VIF” means verify in the field. 13. “VWA” means verify with the Architect. 14. “Align” means to accurately locate finished faces in the same plane.
W3 W3
W4
W3
W4
W3
W4
W3
W4
W3
Therapy room
Therapy room
Therapy room
Private office
Private office
135 SF
144 SF
144 SF
125 SF
126 SF
Therapy room
123 SF
W4
F5
F5
F5
F5
W4
F5
F6
Resource room
Open office
187 SF
281 SF
F6
W2
W2
F5 A
A
A
A
A
A
A
A A
A
F2
F2
F2
F2
UP
Therapy room
Therapy room
ADA bathroom
94 SF
95 SF
64 SF
F5 W3
W1
F5 W4
W3
A
F4
GenderA neutral bathroom
65 SF
W4
A F2
W2
F4
Community share zone
493 SF
W6
A
A
B A
W3
A
UW Student Wellness Center
A
W4
Pet intake room
Egress
Study space
157 SF
213 SF
600 SF
F5
F3
F7
Presentation room
321 SF
F6
W4
W2
W1
1
Level 2 finish 1/4" = 1'-0"
The Moon House
GENERAL NOTES OAK WOOD FLOORING
W1
WHITE PAINT
F2
WHITE GLOSSY BATHROOM TILE
W2
CREAM TEXTURED WALLPAPER
F3
GREY CONCRETE FLOORING
W3
LIGHT BLUE CONSTELLATION WALLPAPER
F4
WOOD LOOK LVT
W4
BLUE GALAXY THEME WALLPAPER
F5
DEEP BLUE CARPET TILE
W5
BLACK & WHITE GALAXY THEME WALLPAPER
F6
LIGHT GREY CARPET TILE
W6
LIGHT BLUE GLOSSY BATHROOM TILE
F7
BLUE & GREY CARPET TILE
B1
GREY PAINT WALL BASE
Floor & wall finish 2
floor & wall finish legend 1/4" = 1'-0"
Project Number 0'
2'
4'
8'
16'
Date Drawn By Checked By
ID4 04/17/2022 Author Checker
AI102.2 Scale
1/4" = 1'-0"
5/10/2022 11:59:28 PM
1. The “General Conditions of the Contract for Construction,” AIA Document A201 governs this work, unless noted otherwise (UNO); most stringent requirements prevail. 2. Investigate field conditions and ascertain that work is feasible as shown. Notify the Architect immediately of any problems with field conditions. 3. Examine specified products and submit written exception or objections, or both, with analysis and recommendations prior to submitting bid costs. 4. Submit horizontal bar chart with separate bar for each major trade or operation, identifying first day of each week; shown projected submittal dates for shop drawings, product data and samples, and product delivery dates, including those for Owner-furnished items. 5. Submit subcontractor contact list. 6. Install drywall work in accordance with the current version of the United States Gypsum-Gypsum Construction Handbook, most stringent requirements prevail. 7. Fabricate and install millwork pursuant to the American Woodwork Institute standards, Premium Grade, flush overlay construction with European style (invisible) self-closing, 170-degree opening, heavy duty hinges, and 100 pound rated full extension side mounted drawer slides, UNO 8. Review shop drawings, product data, samples, etc., review stamp and sign prior to submission, submit one large scale reproducible transparency and one print, clearly showing and identifying components and their assembly. Minimum sheet size: 12 x 24 inches; maximum sheet size: 30 x 42 inches. Allow space for the Architect's review stamp. 9. “Typical” means identical for all similar conditions, UNO. 10. “Similar” means comparable characteristics for the conditions noted; verify dimensions and orientations on plans and elevations. 11. “UNO” means unless noted otherwise. 12. “VIF” means verify in the field. 13. “VWA” means verify with the Architect. 14. “Align” means to accurately locate finished faces in the same plane.
F1