Irex - tech

Page 1

Product Technical Information ITA 517 Ver 1 – 10/11/16 Page 1 / 2

IREX PROFIL DESCRIPTION AND SCOPE OF APPLICATION Vapour control layer in SBS modified bitumen for concrete or wooden decks. •

It is used for : Non accessible flat roofs – Technical flat roofs – Pedestrian terrace – Roof garden or planted terrace – Vehicle access terrace. It is applied by : Torching / Nailing (on wooden decks)

COMPOSITION Main surface Blend Reinforcement Back surface

Sanded SBS elastomeric bitumen Glass mat Thermofusible plastic film

DIMENSIONAL CHARACTERITICS Nominal value 2.9 10 1 37.7

Thickness (mm) Length (m) Width (m) Weight/roll (kg)

Critical value 2.8 9.90 0.99 35.6

PERFORMANCES

Tensile strength Elongation Nail tearing resistance Cold bending resistance Heat flow resistance

Icopal SAS 12, rue de la renaissance F-92184 Antony Cedex France

Norm EN 12311-1 EN 12311-1 EN 12310-1 EN 1109 EN 1110

Unit N/5cm % N °C °C

Tél. : +33(0)1 40 78 35 00 Fax : +33(0)1 45 88 56 87 Contact.fr@icopal.com Contact-international@icopal.com www.siplast.fr

Nominal values 350 x 200 3x2 160 x 160 -20 100

Critical values 320 x 190 2 x 1.9 85 x 85 -15 100

R.C.S. Paris B 552 100 984 Société par Actions Simplifiées au capital de 5 729 600 €