Curtain Wall mullion fixing plate mounted to steel L-Angle
23
Technal MX Curtain Wall Mullions. Base unit to provide flashing. High Spec double glazed panels at 'window' locations.
PIR board & rockwool insulation packed between mullion and cavity
Steel L-Angle for mullion support fixed to columns. Insulation packed between support elements and mullions.
Chamfered Bricks to border of curtain wall
Top Grade Red Clay Bricks to Exterior Line of DPM 100mm Kingspan Rigid Insulation
Ancon de-bonding wall tie back to steel structure
140mm Thick Masonry Blocks
12.5mm Plasterboard Finish to Interior
140
2 Layers Gyproc FireLine 12.5mm Plasterboard Column Encasement
12.5
Service Void
40
102.5 50 100
Kingspan FDEB raised access floor system (based on 4kN/m² loading)
Ground - FFL
160
150 GROUND
300
210
525
25
65
500
0
Line of DPM
65mm Floating Screed
Celotex FR5000 rigid insulation
Concrete ground floor slab Foundation to SE specification and depth