SSU - Ground Junction Detail

Page 1

Curtain Wall mullion fixing plate mounted to steel L-Angle

23

Technal MX Curtain Wall Mullions. Base unit to provide flashing. High Spec double glazed panels at 'window' locations.

PIR board & rockwool insulation packed between mullion and cavity

Steel L-Angle for mullion support fixed to columns. Insulation packed between support elements and mullions.

Chamfered Bricks to border of curtain wall

Top Grade Red Clay Bricks to Exterior Line of DPM 100mm Kingspan Rigid Insulation

Ancon de-bonding wall tie back to steel structure

140mm Thick Masonry Blocks

12.5mm Plasterboard Finish to Interior

140

2 Layers Gyproc FireLine 12.5mm Plasterboard Column Encasement

12.5

Service Void

40

102.5 50 100

Kingspan FDEB raised access floor system (based on 4kN/m² loading)

Ground - FFL

160

150 GROUND

300

210

525

25

65

500

0

Line of DPM

65mm Floating Screed

Celotex FR5000 rigid insulation

Concrete ground floor slab Foundation to SE specification and depth