Prorad
Compact Radiators HIGH EFFICIENCY
HIGH OUTPUT
manufactured to BS EN 442 license No. KM 266 98
TEN YEAR WARRANTY
QUALITY & VALUE
Specifications
Prorad Compact Radiators PRORAD OFFERS SIZES & OUTPUTS AN UP TO DATE (DELTA T 50) COMPACT DESIGN WITH ALL THE STYLE AND QUALITY OF SINGLE CONVECTOR CODE BTU / WATTS MM MORE EXPENSIVE RADIATORS 300mm high
TYPE 11
Heavy duty packaging Corner and edge cartons plus generous bubble wrap designed to protect from damage during transportation and installation.
Slim design For ease of siting.
Factory fitted grills and end panels For solid construction and improved appearance.
All accessories included Air vent, blanking plug, 4 wall plugs, 4 screws and 4 plastic protectors for brackets - for quick and simple mounting.
Delta T 60° Outputs (1000mm radiator) Height (mm) TYPE 11 TYPE 21 TYPE 22 300 400 500 600 700
n/a
n/a
n/a
3045 btu 893 watts 3723 btu 1092 watts 4354 btu 1277 watts 4927 btu 1445 watts
1319 btu 1289 watts 5292 btu 1552 watts 6144 btu 1802 watts 6949 btu 2038 watts
5684 btu 1667 watts 6843 btu 2007 watts 7918 btu 2322 watts 8896 btu 2609 watts
Head Office: F & P Wholesale, Fleet House, Lee Circle, Leicester LE1 3QQ Tel: 0116 256 7380 Fax: 0116 256 7473 F & P Wholesale is part of The BSS Group plc. Registered in England No: 60987 Registered Office: Fleet House, Lee Circle, Leicester LE1 3QQ © F & P. No part of this publication may be reproduced or utilised in any form or by any means, electronic or mechanical, without prior permission from the publisher. Every care is taken to ensure that information quoted in this Brochure is correct at the time of going to press. Prices may be changed without prior notice. E & OE. Copies of our full Terms and Conditions are available from our Head Office.
400 800 1400 1800 2000
411304 411308 411314 411318 411320
500 600 800 1000 1200 1400 1600 1800 2000
411405 411406 411408 411410 411412 411414 411416 411418 411420
400 500 600 700 800 900 1000 1100 1200 1300 1400 1600 1800 2000 2400
411504 411505 411506 411507 411508 411509 411510 411511 411512 411513 411514 411516 411518 411520 411524
400 500 600 700 800 900 1000 1100 1200 1300 1400 1600 1800 2000 2400
411604 411605 411606 411607 411608 411609 411610 411611 411612 411613 411614 411616 411618 411620 411624
732 1462 2559 3290 3656
TYPE 21
TYPE 22
DOUBLE PANEL SINGLE CONVECTOR
DOUBLE CONVECTOR
CODE
CODE
BTU / WATTS
/ / / / /
214 428 750 964 1071
~ ~ ~ ~ ~
~ ~ ~ ~ ~
/ / / / /
~ ~ ~ ~ ~
422304 422308 422314 422318 422320
/ / / / / / / / /
353 422 564 704 844 986 1126 1268 1408
~ ~ ~ ~ ~ ~ ~ ~ ~
~ ~ ~ ~ ~ ~ ~ ~ ~
/ / / / / / / / /
~ ~ ~ ~ ~ ~ ~ ~ ~
422405 422406 422408 422410 422412 422414 422416 422418 422420
/ / / / / / / / / / / / / / /
344 431 517 603 688 775 861 947 1034 1119 1205 1378 1550 1722 2066
421504 421505 421506 421507 421508 421509 421510 ~ 421512 ~ 421514 421516 ~ ~ ~
/ / / / / / / / / / / / / / /
402 503 604 705 805 906 1007 1108 1208 1308 1409 1611 1812 2013 2416
421604 421605 421606 421607 421608 421609 421610 ~ 421612 ~ 421614 421616 ~ ~ ~
/ / / / / / / / / / /
456 570 684 798 912 1025 1142 1368 1595 1824 2052
~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
400mm high 1203 1441 1924 2403 2882 3365 3844 4326 4806
500mm high
600mm high 1374 1718 2063 2407 2747 3091 3436 3779 4124 4465 4809 5497 6183 6870 8243
1667 2085 2500 2919 3333 3752 4167 ~ 5001 ~ 5834 6667 ~ ~ ~
411704 411705 411706 411707 411708 411709 411710 411712 411714 411716 411718
1554 1945 2335 2722 3113 3500 3897 4667 5444 6225 7002
/ / / / /
409 817 1431 1840 2045
422504 422505 422506 422507 422508 422509 422510 422511 422512 422513 422514 422516 422518 422520 422524
/ 567 / 708 / 850 / 991 / 1134 / 1275 / 1416 /~ / 1699 /~ / 1983 / 2266 /~ /~ /~
422604 422605 422606 422607 422608 422609 422610 422611 422612 422613 422614 422616 422618 422620 422624
600mm high 1935 2417 2900 3382 3868 4351 4834 ~ 5799 ~ 6767 7733 ~ ~ ~
2237 2680 3574 4468 5363 6257 7148 8042 8936
/ / / / / / / / /
655 785 1047 1309 1571 1834 2095 2357 2619
/ / / / / / / / / / / / / / /
629 787 944 1101 1258 1416 1574 1731 1889 2046 2203 2518 2832 3147 3776
/ / / / / / / / / / / / / / /
727 909 1090 1272 1454 1635 1817 1999 2180 2362 2544 2907 3271 3634 4361
/ / / / / / / / / / /
816 1021 1225 1429 1633 1838 2042 2450 2858 3267 3674
500mm high / 489 / 612 / 733 / 856 / 978 / 1100 / 1222 /~ / 1466 /~ / 1711 / 1955 /~ /~ /~
2148 2687 3222 3758 4295 4833 5370 5905 6445 6981 7517 8592 9664 10739 12886
600mm high
700mm high 400 500 600 700 800 900 1000 1200 1400 1600 1800
1395 2790 4883 6278 6977
400mm high
500mm high 1175 1469 1764 2059 2350 2644 2939 3233 3528 3818 4114 4703 5288 5877 7052
BTU / WATTS
300mm high
2481 3102 3720 4341 4962 5579 6200 6821 7438 8059 8680 9919 11161 12400 14879
700mm high ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
/ / / / / / / / / / /
~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
BTU / WATTS calculated at Delta T 50 based on mean temperature of 70° Celsius (75-65-20)
422704 422705 422706 422707 422708 422709 422710 422712 422714 422716 422718
2787 3486 4180 4876 5572 6271 6967 8361 9752 11147 12538
DIMENSIONS & WALL MOUNTING INFORMATION TYPE 11
TYPE 21
TYPE 22
BRACKETS
Height 300 400 500 600 700
H 185 285 385 485 585
B 155 255 355 455 555
A ~ 90 190 290 390
RADIATOR LUG POSITIONS
L length (mm) 400 500 600 700 800 900 1000 1100 1200 1300 1400 1600 1800 2000 2400
A B C (mm) (mm) (mm) TYPE TYPE TYPE TYPE 11 21/22 11 21/22 170 200 115 100 60 270 300 115 100 60 370 400 115 100 60 470 500 115 100 60 570 600 115 100 60 670 700 115 100 60 770 800 115 100 60 870 900 115 100 60 970 1000 115 100 60 1070 1100 115 100 60 1170 1200 115 100 60 1370 1400 115 100 60 785 800 115 100 60 885 900 115 100 60 1085 1100 115 100 60
D (mm)
No of Lugs
85 85 85 85 85 85 85 85 85 85 85 85 85 85 85
2 2 2 2 2 2 2 2 2 2 2 2 3 3 3
Prorad Compact Radiators TESTING & OPERATING PRESSURES All models are high pressure tested to withstand 145 psi (13 bar), to perform at a maximum working pressure of 101.5 psi (10 bar) at a maximum temperature of 95°C.
CONNECTIONS Each Prorad radiator has 4 x 1⁄2 inch connections as standard.
APPLICATIONS Prorad radiators are suitable for two pipe installations. For single pipe applications, it is advisable to use diversion tees in the pipework, as this will assist in obtaining design performance from the radiators. Although Prorad is suitable for Microbore pipework, the back tappings make it unsuitable for twin entry valves.
INSTALLATION Everything required for installation can be found within the robust packaging. Brackets are of a strong design, with open top and deep slots, which facilitate easy and secure installation. Plastic inserts seat the radiator precisely on the bracket minimizing expansion and contraction noise. The neat nickel-plated plug and vent provide a watertight joint, whilst complementing the superior finish. Recommended height from the floor to the base of the radiator is 150 mm minimum. This allows adequate airflow when the radiator is placed on the bracket.
WATER TREATMENT On completion of the installation the system should be properly flushed and filled in accordance with the British Standard Code of Practice for the Treatment of Water in Domestic Hot Water Central Heating Systems BS 7593. This will remove flux residues and installation debris, which might promote corrosion and damage within the system. If it is decided to apply a corrosion inhibitor to maximize the working life of the system, it should be applied in accordance with the manufacturer’s instructions and should be suitable for the particular metals within the system.
COAT PAINT PROCESS Each Prorad radiator is subjected to a multi stage cleaning process before the paint is applied. This involves several rinsing stages, including an iron phosphate and demineralization rinse. The first coat of paint is an environmental friendly water based primer paint. The radiator is then stoved and cooled. The second powder coat, in warm white (RAL 9016) is applied and the radiator goes through a final curing stage. It is then allowed to cool prior to packaging.
TEMPERATURE TABLE TEMPERATURES Factors for differences between mean water temperature and room temperature in °C and °F other than 50°C (90°F) °C 5°C 10°C 15°C 20°C 25°C 30°C 35°C 40°C 45°C 50°C 55°C 60°C 65°C 70°C 75°C
°F 0.050 0.123 0.209 0.304 0.406 0.515 0.629 0.748 0.872 1.000 1.132 1.267 1.406 1.549 1.694
10°F 20°F 30°F 40°F 50°F 60°F 70°F 80°F 90°F 100°F 110°F 120°F 130°F 140°F
0.057 0.142 0.240 0.348 0.466 0.590 0.721 0.858 1.000 1.147 1.298 1.454 1.613 1.776
To apply the factors shown in the table to our quoted outputs, multiply the quoted output by the chosen operating factor to give new output. To apply the factor to required output, divide required output by factor to give correct radiator from the Prorad range.
EN 442 CERTIFICATION DATA HLK Height W/m at 75/65/20 n-coefficients Weight (kg/m) Water contents (l/m)
300 515 1.31 9.07 1.87
TYPE 11 400 500 600 677 828 968 1.31 1.31 1.30 12.09 15.11 18.33 2.24 2.62 3.00
700 1096 1.31 21.24 3.38
TYPE 21 500 600 1175 1362 1.31 1.32 25.10 30.50 5.08 5.83
Tested in accordance with BS EN 442
CAUTION When designing for domestic systems we recommend that Prorad be used only in heating systems complying with British Standard Code of Practice for Central Heating For Domestic Premises BS5449 Part 1. Single feed, indirect cylinders are not recommended as should interchange of water occur, fresh aerated water would enter the heating system, resulting in corrosion.
All statistics subject to qualification. Specifications may be changed without prior notice
Professional heating and plumbing products
300 983 1.31 17.50 3.60
TYPE 22 400 500 600 1259 1513 1747 1.32 1.33 1.35 23.57 29.63 35.70 4.37 5.13 5.90
700 1963 1.35 41.70 6.57