Kid's Empire Houston, TX Construction Documents

Page 1

9483 HAVEN AVE, SUITE 100 RANCHO CUCAMONGA, CA 91730 P. 909.259.9971 | F. 909.944.8409 www.AmorArch.com LOS ANGELES | LAS VEGAS | ATLANTA

OWNER

15135 NORTH FREEWAY, HOUSTON, TEXAS 77042

Plotted: 12/20/2018 2:40 PM (jlavenant) File: 01_a2049_t1_1_title sheet.dwg

GAUGE (GAGE) GYPSUM WALLBOARD GENERAL CONTRACTOR GALVANIZED GALVANIZED IRON GLUE-LAMINATED BEAM

HB H.C. H.D. HDR. HDW. HGR. HGT. or HT. H.M. HORIZ. or H H.S.B.

HOSE BIBB HOLLOW CORE HUB DRAIN HEADER HARDWARE HANGER HEIGHT HOLLOW METAL HORIZONTAL HIGH STRENGTH BOLT

I.D. I.E. IN. INSUL. INT. INV.

INSIDE DIAMETER IN EXAMPLE INCH / INCHES INSULATION INTERIOR INVERTED

JT. OR JNT. JST.

JOINT JOIST

QUARRY TILE

RAD. OR (R) RCP R.D. REF. REINF. REV. RQMTS.

RADIUS REFLECTED CEILING PLAN ROOF DRAIN REFERENCE REINFORCEMENT REVERSE REQUIREMENTS

S.C. SCHED. SHT. SHT'G SIM. SM SMS SPEC.(S) SQ. SQ. IN. / FT. S.S. STD. STL. STOR. STRUCT. SUSP. SYM.

SOLID CORE SCHEDULE SHEET SHEATHING SIMILAR SHEET METAL SHEET METAL SCREW SPECIFICATION(S) SQUARE SQUARE INCH / FOOT STAINLESS STEEL STANDARD STEEL STORAGE STRUCTURAL SUSPENDED SYMMETRICAL

TEMP. OR T° THK. T&G T.N. T.O.B. T.O.C. T.O.F. T.O.P. T.O.PL. T.O.S. T.O.W. T.S. TYP. U.N.O. U.L.

TEMPERATURE THICKNESS TONGUE & GROOVE TOE NAIL TOP OF BEAM TOP OF CURB TOP OF FOOTING TOP OF PARAPET TOP OF PLATE TOP OF SLAB TOP OF WALL TOP OF SHEATHING TYPICAL UNLESS NOTED OTHERWISE UNDERWRITERS LABORATORY

VERT. OR (V) V.I.F. V.T.R. V.W.C.

VERTICAL VERIFY IN FIELD VENT THROUGH ROOF VINYL WALL COVERING

w/ or w/o W/C WD. WH W.I.B. W.R. WT. WWF. WWM.

WITH, WITHOUT WATER CLOSET WOOD WATER HEATER WALK-IN BOX WATER RESISTANT WEIGHT WELDED WIRE FABRIC WELDED WIRE MESH

8.

9.

1.0

IF A CONFLICT OCCURS BETWEEN THE DESIGN DRAWINGS AND SPECIFICATIONS, PROMPTLY NOTIFY THE ARCHITECT IN WRITING. AT THAT POINT, A WRITTEN INTERPRETATION WILL BE MADE BY THE ARCHITECT AND SAID DECISION SHALL BE CONSIDERED PART OF THE CONTRACT DOCUMENTS. THIS ARCHITECT WILL NOT HAVE CONTROL OF, AND WILL NOT BE RESPONSIBLE FOR, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK ON THIS PROJECT OR FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR, SUBCONTRACTOR, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK ON THIS SITE, NOR FOR THE FAILURE OF ANY OF THEM TO CARRY OUT THE WORK IN ACCORDANCE WITH THE INTENT OF THE CONTRACT AND OR CONSTRUCTION DOCUMENTS. ALL CONTRACTORS WILL PROVIDE ADEQUATE BRACING AND / OR SHORING TO INSURE STRUCTURAL STABILITY OF THE BUILDING AND ALL RELATED BUILDING COMPONENTS, I.E.; STRUCTURAL WALLS, INTERIOR WALL ASSEMBLIES, ETC. DURING THE CONSTRUCTION PHASE OF THIS PROJECT.

GRID LINE FACE OF STUD FACE OF MASONRY CENTER LINE OF COLUMN

A

N N

NORTH ARROW

2015 INTERNATIONAL FIRE CODE

ENERGY CODE:

2015 INTERNATIONAL ENERGY CONSERVATION CODE

ACCESSIBILITY CODE:

2016 ICC / ANSI A117.1 2012 TEXAS ACCESSIBILITY STANDARDS (TAS)

ACCESSIBILITY

PROJECT SYMBOL IDENTIFICATION CODE COMPLIANCE

101

DOOR NUMBER

101

WINDOW NUMBER

(E) OCCUPANCY GROUP: (N) OCCUPANCY GROUP:

M A-3

MATERIAL NAME / FINISH NAME

CONSTRUCTION TYPE:

II - B NON- SPRINKLERED (NON-SEPARATED PER TABLE 508.4)

P-2

F.O.M. W-1

MERCANTILE ASSEMBLY

M1.0 M2.0 M3.0 MD1.0

HVAC PLAN HVAC SHCEDULES SPECIFICATIONS HVAC DEMO PLAN

E0.1 E0.2 E1.1 E2.1 E3.1 E4.1 E5.1

SHEET INDEX-LEGENDS SPECIFICATIONS ELECTRICAL DEMOLITION PLAN ELECTRICAL POWER PLAN LIGHTING PLAN ONE LINE DIAGRAM AND PANEL SCHEDULES ENERGY COMPLIANCE FORMS

WALL TYPE LEGAL DESCRIPTION

MATERIAL DESIGNATION HEIGHT REFERENCE

ACT-1 +10'-0" NOTE

CPT-1

AP-1

PARCEL NO.

GRAPHIC NAME

FDXSCXX-1

2 ROOM NAME MATERIAL FINISH

2

B

REVISION / ADDENDUM NUMBER

1 KEYNOTE NUMBER TYP

SITE SUMMARY TENANT IMPROVEMENT AREA AGENT / CUSTOMER AREA

± 9,318 S.F. (NO NEW S.F. ADDED)

TOTAL BUILDING HEIGHT

±32'-0" HIGH (EXISTING SINGLE STORY)

PARKING SUMMARY

DEFERRED SUBMITTAL ·

FIRE ALARM

·

BUILDING SIGN

TOPOGRAPHIC SURVEY OF 13.8829 ACRES OUT OF 19.60 ACRES OF UNRESTRICTED RESERVE "I" COMMERCE PARK NORTH AS RECORDED IN VOLUME 303 PAGE 20 OF THE HARRIS COUNTY MAP RECORDS IN HARRIS COUNTY, TEXAS

PROJECT ANNOTATION IDENTIFICATION

ROOM IDENTIFICATION (E) CUSTOMER LOBBY

FIXTURE / EQUIPMENT TYPE

F-1

CEILING IDENTIFICATION

10. UNLESS NOTED OTHERWISE, ALL MATERIALS USED WILL BE NEW AND BEAR U.L. LABELS WHERE REQUIRED AND MEET APPROPRIATE N.E.M.A. OR OTHER INDUSTRY STANDARDS.

12. EACH SUBCONTRACTOR WILL AMEND AND MAKE GOOD AT HIS OWN COST, ANY DEFECTS OR OTHER FAULTS IN HIS WORKMANSHIP AND/OR HIS SUPPLIED MATERIALS.

FIRE / LIFE SAFETY CODE:

THESE PLANS ARE INTENDED TO COMPLY WITH ALL OF THE PROVISIONS SET FORTH BY THE 2012 TEXAS ACCESSIBILITY STANDARDS (TAS)

WORK WILL BE COORDINATED WITH ALL TRADES IN ORDER TO AVOID INTERFERENCE AND AVOID OMISSIONS.

11. LAYOUT ALL PARTITIONS AND CABINETS BEFORE BEGINNING CONSTRUCTION TO PREVENT ERRORS BY DISCREPANCY. ALL DRYWALL PARTITIONS AND CABINETS WILL BE INSTALLED AS NOTED ON THE DRAWINGS. IF APPLICABLE, GENERAL CONTRACTOR MUST OBTAIN RESOLUTION FROM ARCHITECT FOR ANY DISCREPANCIES PRIOR TO CONSTRUCTION OF WALL PARTITIONS AND CABINETS.

2014 NATIONAL ELECTRICAL CODE

PARKING REQUIRED ACCESSIBLE SPACES

SITE & PARKING (EXISTING REMAIN UNCHANGED) ±9,318 S.F. X 5.0/1,000 = (E) 45 9'-0" x 18'-0" = 1 ACCESSIBLE SPACE 9'-0" X 18'-0" = 1 VAN ACCESSIBLE STALL TOTAL = (E) 45 SPACES

N/A

N/A

STAMP

13. VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO ORDERING, CUTTING AND / OR INSTALLING MATERIAL, PRODUCT OR EQUIPMENT. IN THE EVENT OF ANY DISCREPANCIES, CONTACT THE ARCHITECT FOR WRITTEN AND / OR GRAPHIC DIRECTION PRIOR TO PROCEEDING WITH THAT WORK. 14. CONTRACTOR SHALL NOT SCALE THESE DRAWINGS FOR CONSTRUCTION PURPOSES. IN THE EVENT OF OMISSION OF NECESSARY DIMENSIONS OR INFORMATION, CONTRACTOR SHALL NOTIFY THE ARCHITECT. FIGURED AND CALCULATED DIMENSION TAKE PRECEDENCE OVER SCALED MEASUREMENTS. DETAILED DRAWINGS AND LARGER SCALE DRAWINGS TYPICALLY TAKES PRECEDENCE OVER SMALLER SCALE DRAWINGS VERIFY WITH ARCHITECT. ALL PLAN DETAILS AND WALL SECTIONS ARE ASSUMED TO BE TYPICAL CONDITIONS UNLESS DETAILED OR NOTED OTHERWISE. 15. PROVIDE SUFFICIENT BLOCKING IN STUD WALLS TO SUPPORT ALL ITEMS OR EQUIPMENT SHOWN OR SPECIFIED TO BE ATTACHED TO THE WALLS. PROVIDE ADDITIONAL STRUCTURAL SUPPORT (ANGLES, CHANNELS, ETC.) WITHIN WALLS WHERE THE WEIGHT OF ATTACHED ITEMS OR EQUIPMENT IS TOO GREAT TO BE SUPPORTED BY METAL STUDS. PROVIDE BLOCKING FOR OWNER FURNISHED OR INSTALLED ITEMS. 16. WEATHER CONDITIONS: CONTRACTOR(S) WILL PROTECT ALL PARTS OF THEIR WORK FROM WEATHER DAMAGE DUE TO FROST, RAIN, HEAT, ETC. AND WILL MAKE GOOD TO THE SATISFACTION OF THE ARCHITECT ANY PORTION OF THE WORK WHICH MAY HAVE BECOME DAMAGED. 17. SITE SAFETY: EACH CONTRACTOR WILL ABIDE BY LOCAL AREA STANDARDS AND RELATED O.S.H.A. STANDARDS FOR THE PROTECTION AND SAFETY FOR THEIR EMPLOYEES ON SITE. THIS ARCHITECT WILL BE HELD HARMLESS BY KIDS EMPIRE AND GENERAL CONTRACTOR AND RELATED AWARDED TRADES ON THIS PROJECT FOR ACCIDENTS OR INJURIES CAUSED OR ACCRUED ON THIS PROPERTY DURING THE PRE / ACTUAL / POST CONSTRUCTION PHASES OF THIS PROJECT.

TITLE SHEET, PROJECT INFORMATION AND GENERAL NOTES

Q.T.

7.

CONTRACTOR IS RESPONSIBLE FOR THE MORE COSTLY RESOLUTION ON ALL CONFLICTING INFORMATION PRESENTED ON THE PLANS, OR BETWEEN THE EXISTING CONDITIONS AND THE PLANS.

SECTION / ELEVATION / FLOOR DATUM

DETAIL REFERENCE NO.

GRID LINE IDENTIFICATION

ELECTRICAL CODE:

PROJECT REFERENCE N

00 / AX.0

2015 INTERNATIONAL MECHANICAL CODE

SHEET TITLE

PL. P.L. or PL PLAS. PLBG. PLYWD. P.O.C. PR. PSF PSI P.T.

PARTITION PLASTIC LAMINATE OR PARALLAM (BEAM) PLATE PROPERTY LINE PLASTER PLUMBING PLYWOOD POINT OF CONNECTION PAIR POUNDS PER SQ. FOOT POUNDS PER SQ. INCH PRESSURE TREATED

0'-0" FINISH FLOOR

4

3

MECHANICAL CODE:

PROJECT TEAM NOTE: A SIGN PROGRAM SHALL BE REVIEWED AND APPROVED BY THE CITY BEFORE ANY NEW SIGNS ARE INSTALLED ON THE BUILDING

VICINITY MAP

DESCRIPTIVE SUMMARY OF WORK THE WORK INCLUDES ALL LABOR, MATERIALS, AND EQUIPMENT TO BUILD, FINISH, AND PROVIDE ALL WORK FOR A PROPOSED INTERIOR RENOVATION OF EXISTING RETAIL SPACE FOR AN INDOOR PLAYGROUND FOR CHILDREN AND A TODDLER ZONE WITH A IN-HOUSE PANTRY.

PROJECT SITE

THE WORK SHALL INCLUDE ALL ITEMS REQUIRED AS SHOWN ON THE DRAWINGS. ALL ELECTRICAL EQUIPMENT ARE EXISTING TO REMAIN, ALL MECHANICAL HVAC ROOF TOP UNITS ARE EXISTING TO REMAIN WITH MINOR ALTERNATION TO MECHANICAL SYSTEMS, ALL PLUMBING EQUIPMENT ARE EXISTING TO REMAIN. EXISTING ACCESSIBLE MEN'S AND WOMEN'S TOILET ROOMS ARE EXISTING TO REMAIN. EXISTING ACCESSIBLE PARKING STALLS AND PATH OF TRAVEL ARE EXISTING TO REMAIN.

18. CONTRACTORS WILL BE RESPONSIBLE FOR REMOVAL OF DEBRIS ACCUMULATED BY EACH TRADE. HOWEVER, EACH TRADE WILL KEEP THE JOB SITE CLEAN AND SAFE AT ALL TIMES, ALONG w/ A BROOM / VACUUM FINISH AT THE END OF EACH WORKING DAY.

INTERIOR: NEW INTERIOR PARTITION / DOOR / CARPET / VINYL FLOORING/ CEILING TILE

19. TRANSITION OF DIFFERENT FLOORING MATERIALS AT DOORWAYS SHALL OCCUR AT CENTERLINE OF DOORS TYPICALLY.

LIGHT FIXTURE / ELECTRICAL OUTLET, DATA OUTLET AND LIGHT SWITCHES NEW PAINT / GRAPHIC SIGNAGE

20. PAINT ALL WALL SURFACES, DOOR FRAMES, BULKHEADS AND CEILINGS IN ROOMS WHERE INDICATED ON ROOM FINISH SCHEDULE. PAINT BEHIND ALL MOVEABLE ITEMS ADJACENT TO WALLS RECEIVING PAINT AND RELOCATE ITEMS. ALL NEW PAINTING SHALL INCLUDE (1) ONE COAT PRIMER AND (2) TWO COATS OF PAINT.

NOTE:

N

THERE ARE NO KITCHEN IN THIS SCOPE OF WORK AND/OR COOKING OF FOOD OF ANY KIND. EXTERIOR: NEW BUILDING MOUNTED SIGNAGE (UNDER A SEPARATE PERMIT)

C COPYRIGHT 2018 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.

MEP

KIDS EMPIRE 3423 GROMER TERRACE LA CRESCENTA, CA 91214 CONTACT: HAIM ELBAZ PHONE: (424) 527-1039 FAX: EMAIL: direction@kidsempire.us

ECI ENGINEERING CONSULTANTS, INC. 303 FEDERAL WAY BOISE, ID 83705 CONTACT: CHAD PARKER PHONE: (208) 376-9820 FAX: (208) 376-9822 EMAIL: chad@eciboise.com

CLIENT

THIS MAP IS REFERRED FROM GOOGLE MAPS WEBSITE

21. ALL WEATHER - EXPOSED SURFACES SHALL HAVE A WEATHER RESISTIVE BARRIER TO PROTECT THE INTERIOR WALL COVERING AND EXTERIOR OPENINGS SHALL BE FLASHED IN SUCH A MANNER AS TO MAKE THEM WATERPROOF.

OWNER

DOPPS CONSTRUCTION, INC. 142 BONITA AVENUE, SUITE 202 SAN DIMAS, CA 92773 CONTACT: RICK DOPPS PHONE: (714) 738-7045 FAX: (714) 525-9822 EMAIL: pmahajan@pacificcompanies.com

RED ARCH E T M A.

AT

IA

A

CT ITE

GA. GWB G.C. GALV. G.I. GLB.

PART'N P. LAM

6.

ELEVATION REFERENCE IDENTIFICATION

ELEVATION DESIGNATION SHEET REFERENCE NO.

2015 INTERNATIONAL PLUMBING CODE

CONSULTANT

ST

F.G. FLR. FIN. F.O.F. F.O.M. F.O.S. F.R. F.R.P. FT. FTG. F.V.

FACTORY FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER FINISHED FLOOR FINISHED FLOOR LEVEL FURNITURE, FIXTURES & EQUIPMENT FLOAT GLASS FLOOR FINISH FACE OF FINISH FACE OF MASONRY FACE OF STUD FIRE RETARDANT FIBERGLASS REINFORCED PANEL FOOT / FEET FOOTING FIELD VERIFY

O.D. OPN'G. OPP.

SHEET REFERENCE NO.

1 AX.0

PLUMBING CODE:

GENERAL CONSTRUCTION NOTES ADA STANDARDS - ACCESSIBLE DESIGN PLAN EGRESS PLAN EXISTING SITE PLAN DEMOLITION PLAN NEW CONSTRUCTION FLOOR PLAN AND GENERAL NOTES FINISH FLOOR PLAN POWER & SIGNAL PLAN REFLECTED CEILING PLAN AND DETAILS EXISTING ROOF PLAN ENLARGE PLAN AND AND INTERIOR ELEVATIONS - TOILET ROOMS INTERIOR ELEVATIONS AND FINISH SHEDULE INTERIOR ELEVATIONS WALL AND MISCELLANEOUS DETAILS DOOR SCHEDULE, HARDWARE NOTES AND DETAILS

R MO

FACT. F.D. FDN. F.E. F.F. F.F.L. F.F. & E.

OFD. O.F.O.I.

5.

REVISIONS TO WORK OR PLANS MUST BE APPROVED BY THE CITY AND / OR LOCAL JURISDICTION'S INSPECTION SERVICES PRIOR TO IMPLEMENTATION. ANY ADDITIONS OR CHANGES TO WORK MUST BE AUTHORIZED IN WRITING BY THE ARCHITECT. NO ALTERATIONS WILL BE MADE ON THIS PROJECT EXCEPT UPON WRITTEN ORDER BY USING PREDETERMINED ARCHITECT SUPPLEMENTAL INSTRUCTIONS, CHANGE ORDER OR CONSTRUCTION CHANGE DIRECTIVES.

DETAIL DESIGNATION

SHEET REFERENCE NO.

2

2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL EXISTING BUILDING CODE

SECTION DETAIL IDENTIFICATION X AX.0

INTERIOR ELEVATION IDENTIFICATION

BUILDING CODE:

TITLE SHEET, PROJECT INFORMATION, AND GENERAL NOTES

16 5 9 9

AS

EXISTING EACH ELECTRICAL CONTRACTOR ELECTRICAL ELEVATION EDGE NAIL EDGE OF COUNTER / EQUIPMENT EQUAL EXISTING RELOCATED EXPANSION EXTERIOR

ON CENTER OWNER FURNISHED, CONTRACTOR INSTALLED OVERFLOW DRAIN OWNER FURNISHED, OWNER INSTALLED OUTSIDE DIAMETER OPENING OPPOSITE

THE CONTRACTOR SHALL FOCUS SPECIAL ATTENTION ON A FIELD REVIEW OF THE EXISTING SITE PRIOR TO CONSTRUCTION. ANY CONDITIONS THAT ARE FOUND TO BE INCONSISTENT WITH THESE DOCUMENTS OR WHERE THE INTENT IS IN DOUBT SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR RESOLUTION PRIOR TO BID SUBMITTAL. CONTRACTOR SHALL NOT RELY UPON ORAL COMMUNICATIONS; ALL COMMUNICATIONS MUST BE IN WRITTEN OR GRAPHIC FORMAT.

CURRENT CODES

SHEET REFERENCE NO.

SECTION DESIGNATION X AX.0

1 2 3 4 5 T1.1 T1.2 T1.3 T1.4 AS1.1 AD1.1 A1.1 A1.2 A1.3 A2.1 A3.1 A6.1 A6.2 A6.3 A7.1 A8.1

15135 NORTH FREEWAY, HOUSTON, TEXAS 77042

(E) EA. E.C. ELEC. ELEV. E.N. E.O.C. EQ. or = ER EXP. EXT.

O.C. O.F.C.I.

4.

PARTIAL SECTION IDENTIFICATION

PROPOSED TENANT IMPROVEMENT / ALTERATION CONSTRUCTION OF AN (E) RETAIL SPACE

TENANT IMPROVEMENT GARDEN CENTER SUITE #800

DOUBLE DEGREE DETAIL DIAMETER DIAGONAL DIMENSION DOWNSPOUT DRAWING(S)

NEW NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE

3.

X AX.0 SHEET REFERENCE NO.

(WHERE APPLY) MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS ARE INCLUDED IN, AND NOT SUPPLEMENTARY TO, THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO CHECK THE ARCHITECTURAL DRAWINGS BEFORE INSTALLATION OF THEIR WORK. ANY DISCREPANCY BETWEEN THE ARCHITECTURAL AND OTHER DRAWINGS SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION BY THE CONTRACTOR FOR WRITTEN AND GRAPHIC CLARIFICATION.

PROPOSED USE

DETAIL DESIGNATION

ELEVATION DESIGNATION X AX.0

REVISIONS

ENLARGED DETAIL IDENTIFICATION

WIL L

DBL. DEG. or ° DET. DIA. or Ø DIAG. DIM. DS. DWG.(S)

(N) NA OR N/A N.I.C. NO. or # NOM. N.T.S.

2.

ELEVATION IDENTIFICATION

KIDS EMPIRE USA, LLC

CONDUIT CENTER LINE CABINET CEMENTITIOUS BACKER BOARD CORE DRILL CERAMIC CONTROL JOINT (COLD JOINT) CEILING CAULKING CLEAR CONCRETE MASONRY UNIT COLUMN CONCRETE CONNECTION CONSTRUCTION CONSTRUCTION JOINT CONTINUOUS CONTRACTOR COMPACTED / COMPACTION CERAMIC TILE

M.S.B. MTD. MTL.

MATERIAL MAXIMUM / MINIMUM MACHINE BOLT MEZZANINE MISCELLANEOUS MASONRY OPENING MODULAR PANELBOARD SYSTEM MAIN SWITCH BOARD MOUNTED METAL

ALL CONTRACTORS AND SUBCONTRACTORS WILL THOROUGHLY FAMILIARIZE THEMSELVES WITH THESE CONSTRUCTION DOCUMENTS AND WILL VERIFY EXISTING SITE AND CONDITIONS PRIOR TO SUBMITTING A BID. ALL SUBCONTRACTORS WILL PROVIDE ALL LABOR, SUPERVISION, AND MATERIALS OF EVERY TYPE WHICH MAY BE NECESSARY FOR A SUCCESSFUL COMPLETION. ALL WORK TO BE PERFORMED IN A GOOD AND WORKMANLIKE MANNER ACCORDING TO THE TRUE INTENT AND MEANING OF THE DRAWINGS AND SPECIFICATIONS.

REG IS

C C.L. or CL CAB. C.B.B. C.D. CER. C.J. CLG. CLKG. CLR. C.M.U. COL. CONC. CONN. CONST. CONST. JT. CONT. CONTR. COMP C.T.

MAT'L. MAX. / MIN. M.B. MEZZ. MISC. M.O. M.P.S.

1.

PROJECT LOCATION

BOARD BLOCKING BOUNDARY NAIL BEAM BOTTOM OF CEILING BOTTOM OF JOIST BUILT-UP ROOFING BOTTOM

ANGLE LAMINATED LAVATORY POUND(S) LONG LIGHT

ARCHITECTURAL

BD. BLK'G B.N. BM. B.O.C. B.O.J. B.U.R. BOTT. or (B)

L LAM. LAV. LB(S). or # LG. LT.

SHEET INDEX

MECHANICAL

ANCHOR BOLT ABOVE ASPHALTIC CONCRETE ALUM. COMPOSITE METAL PANEL ACOUSTIC CEILING PANEL ABOVE FINISH FLOOR ALUMINUM ABRASIVE QUARRY TILE ARCHITECT OF RECORD ARCHITECTURAL

PROJECT INFORMATION

ELECTRICAL

A.B. ABV. A.C. ACM A.C.P. A.F.F. ALUM. A.Q.T. AOR ARCH.

SYMBOL AND LEGEND

PLUMBING

(NOT ALL ABBREVIATIONS MAY BE USED IN THIS DOCUMENT)

GENERAL NOTES

F.O.S.

ABBREVIATIONS

9700 WESTCHASE, LLC, A DELAWARE LIMITED LIABILITY COMPANY TENANT INTERIOR WORK

E OF T EX

SHEETS BEARING THIS SEAL AND WET SIGNATURE ARE AUTHENTICATED. RESPONSIBILITY FOR ALL OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS ARE DISCLAIMED.

REVISIONS 2018-12-20

ISSUED FOR PLAN CHECK

2018-12-20

ISSUED FOR HEALTH DEPT. PLAN CHECK

LANDLORD REP ORR COMMERCIAL, INC. 5400 KATY FREEWAY, SUITE 100 HOUSTON, TX 77007 CONTACT: CAMPBELL ANDERSON PHONE: (713) 554-6505 FAX: (713) 468-7774 EMAIL: pmahajan@pacificcompanies.com

ARCHITECT AMOR ARCHITECTURAL CORPORATION 10300 4TH STREET, SUITE 100 RANCHO CUCAMONGA, CA 91730 CONTACT: BILL BEEBE PHONE: (909) 259-9971 FAX: (909) 944-8409 EMAIL: Bbeebe@AmorArch.com

DATE 2018.11.28 PROJECT NUMBER A2049

SHEET NUMBER

T1.1


GENERAL RESPONSIBILITIES 1.

2.

3.

4.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY ALL CONTACT INFORMATION REGARDING THE PROJECT SITE TO INCLUDE NAMES AND TELEPHONE NUMBERS. CONTACTS SHOULD INCLUDE STORE MANAGER, LANDLORD / PROPERTY MANAGER, CITY BUILDING INSPECTORS, FIRE DEPARTMENT INSPECTORS, ETC. THIS MUST BE DONE AT LEAST (2) TWO WEEKS PRIOR TO START OF CONSTRUCTION SO THAT G.C. CAN GAIN ACCESS TO ALL AREAS OF THE SITE AND COMPLETE ALL NECESSARY INSPECTIONS FOR THE PROJECT. THE GENERAL CONTRACTOR SHALL PROVIDE STORAGE CONTAINERS, IF NECESSARY, TO RECEIVE CONSTRUCTION ITEMS SUCH AS MILLWORK, CONVEYOR SYSTEM, CART, ETC. G.C. SHALL, UPON RECEIVING OF OWNER FURNISHED ITEMS, REPORT ALL DAMAGED OR MISSING PARTS OR COMPONENTS TO THE ARCHITECT IMMEDIATELY. G.C. MUST COORDINATE FOR THE DELIVERY OF OWNER FURNISHED ITEMS TO BE PLACED IN THE G.C.'s DESIGNATED STORAGE CONTAINER LOCATION (2) TWO DAYS PRIOR TO START OF INSTALLATION OF THESE ITEMS. IT IS THE INTENT OF THE TENANT TO SALVAGE AND RECYCLE AS MUCH OF THE EXISTING MATERIALS AT THE JOBSITE AS POSSIBLE. FOR THE EXISTING MILLWORK, GENERAL CONTRACTOR SHALL PHYSICALLY VERIFY IF THE FIXTURES ARE STILL IN GOOD OR REASONABLE CONDITION FOR REUSE AT OTHER TENANT FACILITIES. G.C. SHALL INFORM THE TENANT OF HIS ANALYSIS. IF IT IS VERIFIED THAT THE FIXTURES ARE SO DAMAGED THAT IT WOULD NOT BE WORTH SALVAGING, THEN THE FIXTURES WOULD BE DEMOLISHED. IF THE FIXTURES ARE SALVAGEABLE WHEN DISCONNECTED FROM ITS CURRENT LOCATION, THEN THE G.C. SHALL MOVE THEM INTO THE EXISTING WAREHOUSE AT A LOCATION DETERMINED WITH THE TENANT AND / OR STORE MANAGER. THE TENANT SHALL PICK THE FIXTURES UP AT A LATER TIME FOR STORAGE AND FUTURE REUSE. FOR OTHER MATERIALS, THE G.C. SHALL PROVIDE AN ALTERNATE PRICE IN THE PROJECT BID FORM TO THE TENANT TO RECYCLE THESE MATERIALS (I.E., CEILING TILES, DRYWALL, DOORS, FLOORING, ETC.) THE TENANT SHALL INFORM THE G.C. WHETHER TO RECYCLE THE MATERIALS OR TO HAUL AWAY TO THE LOCAL LANDFILL. THE G.C. IS RESPONSIBLE FOR MATERIALS AND LABOR REQUIRED FOR ANY ALTERATIONS TO FIRE SPRINKLERS, ELECTRICAL EQUIPMENT, PLUMBING, EMERGENCY & EXISTING LIGHTING, ALARM AND MECHANICAL SYSTEMS AS REQUIRED TO COMPLETE THE PROJECT AND OBTAIN FINAL INSPECTIONS.

5.

ANY DISCREPANCIES BETWEEN THESE DOCUMENTS AND THE ACTUAL FIELD CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING WITH ANY WORK.

6.

THE GENERAL CONTRACTOR SHALL REVIEW ALL DOCUMENTS AND VERIFY ALL DIMENSIONS AND FIELD CONDITIONS AND SHALL CONFIRM THAT WORK IS CONSTRUCTIBLE AS SHOWN. ANY CONFLICTS OR OMISSIONS, ETC., SHALL BE IMMEDIATELY REPORTED TO THE ARCHITECT FOR CLARIFICATION PRIOR TO THE PERFORMANCE OF ANY WORK IN QUESTION.

7.

Plotted: 12/20/2018 1:10 PM (jlavenant) File: 02_a2049_t1.2_gc notes.dwg

10. THE GENERAL CONTRACTOR IS RESPONSIBLE TO FOLLOW OWNER's GROUP RULES AND REGULATIONS. WHEN THE G.C. ACCEPTS DELIVERY OF ALL ITEMS NOTED ON PLANS WHETHER IN CONTRACT OR NOT IN CONTRACT, (S)HE SHALL BE RESPONSIBLE FOR LOSS AND/OR DAMAGE TO THESE ITEMS.

11. THE GENERAL CONTRACTOR SHALL MAINTAIN, FOR THE ENTIRE DURATION OF THE WORK, ALL EXITS, EXIT / EGRESS LIGHTING, FIRE PROTECTION DEVICES AND ALARMS IN CONFORMANCE WITH ALL APPLICABLE CODES AND ORDINANCES.

12. ALL SAW CUTTING AND CORING LOCATIONS SHALL BE REVIEWED IN FIELD BY THE GENERAL CONTRACTOR AND COORDINATED WITH THE OWNER's REPRESENTATIVE PRIOR TO CUTTING / CORING.

13. DURING ALL PHASES OF WORK, DO NOT DISTURB THE DELIVERIES AND FUNCTIONS OF ALL ADJACENT AND NEIGHBORING TENANTS. 14. PROVIDE PORTABLE FIRE EXTINGUISHER(S) IN ACCORDANCE WITH NFPA 10, WITH U.L. LABEL AND A RATING OF NOT LESS THAN 2-A WITH 75 FEET OF TRAVEL DISTANCE TO ALL POSITIONS OF STORE AND / OR AS DIRECTED BY THE FIRE DEPARTMENT FIELD INSPECTOR. 15. ALL EXTERIOR BUILDING SIGNAGES SHALL BE SUBMITTED UNDER SEPARATE PERMIT APPLICATION FOR REVIEW AND APPROVAL AS REQUIRED BY LOCAL AUTHORITIES. EXTERIOR SIGNAGES ARE NOT WITHIN THE SCOPE OF BUILDING DEPARTMENT APPROVAL. 16. PRIOR TO COMMENCEMENT OF ANY WORK - THE OWNER OR OWNER'S REPRESENTATIVE SHALL ENGAGE LICENSED DESIGN PROFESSIONAL(S) TO PROVIDED ALL REQUIRED DOCUMENTATION FOR REVIEW, AND RECEIVE APPROVAL BY THE LOCAL AUTHORITIES HAVING JURISDICTION. INCLUDING BUT NOT LIMITED TO STRUCTURAL VERIFICATION AND DESIGN, BUILDING, FIRE, LIFE SAFETY, HEALTH, PLUMBING, ELECTRICAL, AND MECHANICAL APPROVALS. 17. IF REQUIRED BY LOCAL JURISDICTION - SPRINKLER, LIFE SAFETY, AND FIRE ALARM SYSTEMS ARE TO BE DESIGNED AND SUBMITTED FOR REVIEW AND APPROVAL BY LOCALLY LICENSED DESIGN PROFESSIONAL. THE DESIGN OF ALL SYSTEM(S) MUST COMPLY TO ALL FEDERAL, NATIONAL, STATE, AND LOCAL CODES AND ORDINANCES. 18. EXISTING ENERGY MANAGEMENT SYSTEM (VERIFY IN FIELD) TO REMAIN IN STORE AND BE FULLY FUNCTIONAL AND OPERATIONAL AT COMPLETION OF REMODEL PROJECT.

CABINET WORK 1. MAKE ALL FINISHED WORK PER THE DETAILED DRAWINGS. 2. TAKE SUCH FIELD MEASUREMENTS AS MAY BE REQUIRED. 3. ALL FINISHED CABINET MATERIALS TO BE AS CALLED OUT PER THE CONSTRUCTION DOCUMENTS. 4. PLASTIC LAMINATE FINISHING SHALL CONFORM TO REQUIREMENTS OF ARCHITECTURAL WOODWORK INSTITUTE. "QUALITY STANDARDS" FOR "CUSTOM" GRADE AND NOTES CONTAINED HEREIN. 5. INSTALLATION - INSTALL UNITS LEVEL AND PLUMB WITH TIGHT JOINTS BETWEEN ANY MULTIPLE UNITS. SCRIBE TO WALL AND OTHER SURFACES AS REQUIRED. ADJUST ALL DRAWERS, DOORS AND MOVABLE PARTS TO OPERATE EASILY AND SMOOTHLY WITHOUT BINDING. 6. ALL DRAWERS TO BE FULL EXTENSION SIDES WITH A 75 LBS. LOAD CAPACITY.

A. PRIOR TO COMMENCING, THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL REVIEW ALL DRAWINGS AND SPECIFICATIONS AND VERIFY CONDITIONS AT THE SITE. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. CONTRACTOR SHALL VERIFY w/ THE PROPER UTILITY COMPANY OR OTHER AGENCY OR COMPANY THE LOCATIONS OF ALL EXISTING BELOW GRADE UTILITIES AND THEIR SERVICE CONNECTION PRIOR TO THE COMMENCEMENT OF WORK.

8. THE GENERAL CONTRACTOR AND MILLWORK CONTRACTOR ARE TO COORDINATE AND INSTALL ALL REQUIRED BLOCKING, ANGLE BRACES, SUPPORTS, ETC., TO SUFFICIENTLY SUPPORT ALL COUNTERS.

D. CONTRACTOR TO VERIFY AND ENSURE AVAILABILITY AND TIMELY DELIVERY OF SPECIFIED OR SUBSTITUTED PRODUCTS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY ARCHITECT OF POSSIBLE CHANGES TO CONSTRUCTION DOCUMENTS OR ANY CONSTRUCTION DELAY DUE TO NON AVAILABILITY OR LATE DELIVERY OF MATERIALS. CONTRACTOR (& NOT THE ARCHITECT) IS RESPONSIBLE FOR NON AVAILABILITY OR LATE DELIVERY OF PRODUCTS DURING CONSTRUCTION.

9. FINISHES COUNTERTOP FINISHES TO BE PER FINISH SCHEDULE AND / OR SHOP DRAWINGS CABINET FACES TO BE PER FINISH SCHEDULE AND / OR SHOP DRAWINGS

E. ANY CONTRACTOR PRIOR TO INSTALLATION OR PROCUREMENT OF MATERIALS SHALL NOTIFY ARCHITECT OF PROBLEMS IF ANY. FAILURE TO DO SO SHALL MEAN THAT ALL NECESSARY CORRECTIVE MEASURE, DOCUMENTATION, ETC. SHALL BE DONE BY THAT CONTRACTOR AT HIS OWN EXPENSE AND TIME.

10.HARDWARES TO BE AS CALLED OUT PER PLANS AND SCHEDULES. (TYPICAL)

F. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURACY OF THE BUILDING LINES AND LEVELS. THE CONTRACTOR SHALL COMPARE CAREFULLY THE LINES AND LEVELS SHOWN ON THE DRAWINGS WITH EXISTING LEVELS FOR THE CONSTRUCTION OF THE WORK AND SHALL BRING TO THE ARCHITECT'S ATTENTION OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK.

7. MILLWORK CONTRACTOR IS TO PROVIDE SHOP DRAWINGS FOR REVIEW AND APPROVAL PRIOR TO FABRICATION.

ELECTRICAL - IN ACCORDANCE TO DETAIL 12 / T1.3 1. BOTTOM OF ELECTRICAL OUTLET J-BOXES SHALL BE INSTALLED NOT LESS THAN 15" ABOVE THE FINISHED FLOOR OR WORKING PLATFORM. 2. THE TOP OF THE J-BOX OF CONTROLS OR SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES, OR COOLING, HEATING, AND VENTILATING EQUIPMENT SHALL NOT BE MORE THAN 48" ABOVE THE FINISHED FLOOR OR WORKING PLATFORM. 3. THE TOP OF FIRE ALARM INITIATING DEVICES (BOXES) SHALL BE LOCATED 48" ABOVE THE LEVEL OF THE FINISHED FLOOR, WORKING PLATFORM, GROUND SURFACE OR SIDEWALK. 4. THE INSTALLATION OF FIRE ALARM EQUIPMENT AND SYSTEMS IN ANY OCCUPANCY WITHIN THE SCOPE OF THESE REGULATIONS SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF THE LOCAL, STATE & FEDERAL CODES AND REGULATIONS. 5. (WHERE APPLIES,) GENERAL CONTRACTOR TO SUPPLY (N) PANEL SCHEDULES FOR ALL ELECTRICAL PANELS PRIOR TO COMPLETION OF THE REMODEL.

HAZARDS AND PROTRUDING OBJECTS - IN ACCORDANCE TO DETAIL 8 / T1.3 1. OBJECTS PROJECTING FROM WALLS WITH THEIR LEADING EDGES ABOVE 27" AND BELOW 80" ABOVE THE FINISHED FLOOR SHALL PROTRUDE NO MORE THAN 4" INTO WALKS, HALLS, CORRIDORS, PASSAGEWAYS, OR AISLES. 2. OBJECTS MOUNTED WITH THEIR LEADING EDGES AT OR BELOW 27" ABOVE THE FINISHED FLOOR MAY PROTRUDE ANY AMOUNT INTO WALKS, HALLS, CORRIDORS, PASSAGE WAYS OR AISLES. ANY OBSTRUCTION THAT OVERHANGS A PEDESTRIAN WAY SHALL BE A MINIMUM OF 80" ABOVE THE WALKING SURFACE AS MEASURED FROM THE BOTTOM OF THE OBSTRUCTION. 3. FREESTANDING OBJECTS MOUNTED ON POSTS OR PYLONS MAY OVERHANG 12" MAXIMUM FROM 27" TO 80" ABOVE THE GROUND OR FINISHED FLOOR. 4. PROTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR WIDTH OF AN ACCESSIBLE ROUTE OR MANEUVERING SPACE. 5. WALKS, HALLS, CORRIDORS, PASSAGEWAYS, AISLES OR OTHER CIRCULATION SPACES SHALL HAVE 80" (INCHES) MINIMUM CLEAR HEAD ROOM. 6. CONTRACTOR TO CONTACT ARCHITECT IF ROOF PENETRATIONS ARE DEEMED NECESSARY. ANY ROOF PENETRATIONS MUST BE COMPLETED BY LANDLORD APPROVED ROOFING CONTRACTOR.

SIGNAGE 1. THE SIGNAGE AT THE STOREFRONT WILL BE CONTRACTED DIRECTLY BY THE GENERAL CONTRACTOR. THE G.C. MUST PROVIDE ANY AND ALL REQUIRED J-BOXES AS WELL AS ACCESS PANELS TO ALL SIGNAGE AS NECESSARY. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION WITH ITS SIGN CONTRACTOR AND MAKING SURE THE JOB IS DONE ON TIME. FULLY DETAILED SHOP DRAWINGS MUST BE SUBMITTED TO THE ARCHITECT FOR REVIEW. THESE ARCHITECTURAL PLANS ONLY SHOW LIMITED DESIGN DETAILS AND ARE NOT ADEQUATE FOR CONSTRUCTION OF THE SIGN. SEE SIGN SHOP DRAWINGS. SIGN DRAWINGS WILL BE PREPARED BY OTHERS AND ARE UNDER SEPARATE PERMIT. 2. BARRIER LAWS FOR THE PHYSICALLY HANDICAPPED ARE MINIMUM GUIDELINES. SHOULD THERE BE A CONFLICT BETWEEN THESE MINIMUM REQUIREMENTS AND WHAT IS CALLED FOR ON THE DRAWINGS, THE CONTRACTOR IS TO INFORM THE ARCHITECT FOR WRITTEN AND/OR GRAPHIC CLARIFICATION PRIOR TO PROCEEDING WITH WORK SO AFFECTED.

FIRE SPRINKLER SYSTEM

(WHERE APPLIES) IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VERIFY IF THE EXISTING FIRE SPRINKLER SYSTEM NEEDS TO BE MODIFIED IN ORDER TO ACCOMMODATE THE RENOVATION SPACE. THIS INCLUDES ALL AFFECTED AREAS TO INCLUDE MAIN LOBBY AND ADJACENT ROOMS. IF REQUIRED, THE CONTRACTOR MUST SUBMIT FIRE SPRINKLER SHOP DRAWINGS AND OBTAIN A FIRE SPRINKLER PERMIT FROM THE LOCAL FIRE DEPARTMENT AND / OR BUILDING DEPARTMENT. ALL COSTS AND FEES SHOULD BE INCLUDED IN THE CONTRACTOR'S BID PROPOSAL TO THE OWNER. AT THE COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN AN INSPECTION FOR APPROVAL AND SIGN-OFF FOR THE MODIFIED FIRE SPRINKLER SYSTEM BY THE FIRE DEPARTMENT AND BUILDING INSPECTOR.

PLUMBING

G. PROVIDE ALL NECESSARY BACKING AND FRAMING FOR ALL WALL MOUNTED ITEMS, LIGHT FIXTURES AND ALL OTHER ITEMS REQUIRED.

6. LIABILITIES A. THE DESIGN PROFESSIONAL (DP) SHALL CONSULT WITH THE CLIENT REGARDING THE PROBABLE SERVICES REQUIRED TO COMPLY WITH BUILDING CODES AND AMERICANS with DISABILITIES ACT (ADA). THE DP IS NOT AN ATTORNEY NOR SHOULD THE DP'S RENDERING AN OPINION OF PROBABLE SERVICES REQUIREMENTS BE CONSIDERED EQUIVALENT TO A LEGAL INTERPRETATION OF ADA. THE DP'S OPINION WILL BE BASED SOLELY ON HIS / HER OWN EXPERIENCE AND KNOWLEDGE. THIS REQUIRES THE DP TO MAKE A CERTAIN NUMBER OF ASSUMPTIONS AS TO THE TYPES OF DISABILITIES COVERED BY ADA. THE DEGREE OF ACCESS THAT IS READILY ACHIEVABLE AND WHAT CONSTITUTES 'READILY ACCESSIBLE AND USABLE'. GIVEN THE ASSUMPTIONS WHICH MUST BE MADE THE DP CANNOT AND DOES NOT GUARANTEE THE ACCURACY OF HIS / HER OPINION AS TO FULL COMPLIANCE AND IN RECOGNITION OF THAT FACT, THE CLIENT WAIVES ANY CLAIM AGAINST THE DP RELATIVE TO THE ADEQUACY OF THE OPINION TO FULLY COMPLY WITH BUILDING CODES AND ADA REQUIREMENTS. B. THE ARCHITECT WHO SIGN THESE PLANS, SPECIFICATIONS AND OTHER INSTRUMENTS OF SERVICE SHALL NOT BE HELD RESPONSIBLE FOR DAMAGES RESULTING FROM CHANGES OR USES NOT AUTHORIZED OR APPROVED BY THE ARCHITECT. THE SIGNING OF THESE DOCUMENTS WILL NOT IMPOSE A LEGAL DUTY OR RESPONSIBILITY TO OBSERVE THE CONSTRUCTION AND / OR INSTALLATION OF THE FIXED WORKS SUBJECT TO THESE DOCUMENTS. C. ALL BRACING NECESSARY FOR CONSTRUCTION PURPOSES SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. D. THE DESIGN ADEQUACY AND SAFETY OF THE ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC, SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE PRIOR TO THE APPLICATION OF ALL SHEAR WALLS, ROOF AND FLOOR DIAPHRAGMS AND FINISH MATERIALS. THE CONTRACTOR SHALL PROVIDE THE NECESSARY BRACING TO PROVIDE STABILITY PRIOR TO THE APPLICATION OF THE AFOREMENTIONED MATERIALS. OBSERVATION VISITS TO THE SITE BY THE ARCHITECT SHALL NOT INCLUDE INSPECTION OF THE ABOVE ITEMS.

7. INTENTION UNLESS NOTED OTHERWISE, THE INTENTION OF THE DOCUMENTS IS TO INCLUDE ALL LABOR, MATERIALS AND EQUIPMENT & TRANSPORTATION NECESSARY FOR COMPLETE AND PROPER EXECUTION OF THE WORK.

8. SUBSTITUTION NO SUBSTITUTION SHALL BE MADE WITHOUT THE ARCHITECT'S APPROVAL.

10. SCOPE ALL TRADES SHALL FURNISH ALL LABOR, EQUIPMENT, MATERIALS AND PERFORM ALL WORK NECESSARY. REASONABLY INFERRED OR REQUIRED BY ANY CODE OR REGULATION ADOPTED BY LOCAL JURISDICTION, TO COMPLETE THEIR SCOPE OF WORK FOR A COMPLETE AND PROPERLY FINISHED JOB.

11. CUTTING AND PATCHING ALL TRADES SHALL DO THEIR OWN CUTTING, FITTING, PATCHING, ETC. TO MAKE THE SEVERAL PARTS COME TOGETHER PROPERLY AND FIT IT TO RECEIVE OR BE RECEIVED BY WORK OF OTHER TRADES.

INSTALL

FURNISH

INSTALL

FURNISH

INSTALL

FURNISH

EXISTING

1. STEEL FRAMING A. METAL STUDS, TRACK & FASTENERS 2. MISCELLANEOUS

CONSULTANT

GENERAL REQUIREMENTS

DIVISION 08 - OPENINGS

1. INTERIOR DOORS & FRAMES N/A

2. HOLLOW METAL FRAMES 3. SPECIALTY DOORS

N/A

A. RATED DOORS (AS REQ'D) B. DOORS (AS REQ'D) 4. DOOR HARDWARE

N/A

5. WINDOW BLINDS DIVISION 09 - FINISHES

1. GYPSUM WALLBOARD & ACCESSORIES A. INTERIOR PARTITIONS (FRAMING & GYP.) N/A

B. COLUMN ENCLOSURES C. HARD LID CEILING 2. CEILING SYSTEMS A. ACOUSTIC TILE B. SUSPENDED CEILING SYSTEM 3. PAINTING 4. FLOORING (PUBLIC AREA) A. ENTRY FLOORING B. CUSTOMER AREA FLOORING C. BACK COUNTER AREA FLOORING D. RUBBER BASE * CLEAN AND REPAIR TO "LIKE-NEW" CONDITION DIVISION 10 - SPECIALTIES

1. INTERIOR SIGNAGE AND GRAPHICS A. BRAND / LOGO SIGNAGE (WALL MTD.) B. INTERIOR GRAPHICS & SIGNAGE 2. EXTERIOR SIGNAGE A. MONUMENT SIGN & ASSOC. WIRING B. STOREFRONT SIGNAGE (WALL MTD.) C. AWNING / CANOPY DIVISION 11 - EQUIPMENT

1. CONVEYOR

N/A

2. CONVEYOR SCALE

N/A

3. CARTS

N/A

4. CART CORRAL

N/A

DIVISION 12 - FURNISHINGS

N/A

1. P.O.S. COMPUTER (ELECTRONICS) 2. FURNITURE

4. RUBBER BASE 5. P.O.S. SCALE

N/A

6. DUAL DISPLAYS

N /A

DIVISION 22 - NOT USED

(WHERE APPLIES) GENERAL CONTRACTOR TO PERFORM A LINE JETTING OF ALL PLUMBING LINES AFTER NEW WORK IS COMPLETE. GENERAL CONTRACTOR MUST SUPPLY CERTIFICATE OF INVOICE WITH CLOSE OUT PACKAGE.

C COPYRIGHT 2018 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.

RED ARCH E T M A. IA

A

AT

16 5 9 9

E OF T EX

SHEETS BEARING THIS SEAL AND WET SIGNATURE ARE AUTHENTICATED. RESPONSIBILITY FOR ALL OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS ARE DISCLAIMED.

DIVISION 23 - HVAC

1. SUPPLY / RETURN REGISTERS REVISIONS * CLEAN AND RE-USE EXISTING

DIVISION 26 - ELECTRICAL

2018-12-20

ISSUED FOR PLAN CHECK

2018-12-20

ISSUED FOR HEALTH DEPT. PLAN CHECK

1. LIGHT FIXTURES A. LIGHT FIXTURES REPLACE IF DISCOLORED OR NOT WORKING *

B. EMERGENCY EXIT LIGHTING 2. OUTLETS, SWITCHES, WIRING, CONDUIT 3. WIRING FOR DATA AND VOICE

REMOVE ANY EXISTING SECURITY CAMERAS **

4. SECURITY CAMERAS

DATE 2018.11.28

5. SPEAKERS *

CLEAN AND RE-USE EXISTING

** CAREFULLY REMOVE AND RE-INSTALL (E) SECURITY CAMERA (DURING CEILING WORK)

THE CONTRACTOR SHALL CLEANUP, REMOVE AND RECYCLE IN A LEGAL MANNER AND NOT DISPOSE IN LANDFILL ALL DEBRIS AND WASTE ATTRIBUTED TO THE JOB. GENERAL CONTRACTOR TO KEEP AN ACCURATE RECORD OF CHANGES IN FIELD AND SUBMIT A COMPLETE SET OF AS-BUILT DRAWINGS TO THE ARCHITECT FOR HIS / HER REVIEW AND TO THE OWNER. FOREMAN TO HAVE AN ACCURATE FLOOR PLAN AND PROJECT SCHEDULE ON-SITE AT ALL TIMES.

STAMP

G.C. TO ORDER AND INSTALL

3. FIXTURES

12. CLEANING 13. (AS-BUILT) DRAWINGS

9700 WESTCHASE, LLC, A DELAWARE LIMITED LIABILITY COMPANY TENANT INTERIOR WORK

DIVISION 06 & DIVISION 07 - NOT USED

9. CHANGES THE OWNER OR ARCHITECT MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO, OR DEDUCTING FROM THE WORK. THE CONTRACT SUM BEING ADJUSTED ACCORDINGLY.

N/A

DIVISION 05 - METALS

B. NO CONTRACTOR OR SUB-CONTRACTOR IS TO START ANY WORK UNTIL A THOROUGH EXAMINATION OF ALL THE EXISTING CONDITIONS IS PERFORMED. IF FOR ANY REASON A SATISFACTORY JOB IS IMPOSSIBLE, IT SHALL BE IMMEDIATELY REPORTED TO THE PROJECT SUPERINTENDENT AND ARCHITECT FOR WRITTEN OR GRAPHIC CLARIFICATION BEFORE PROCEEDING WITH THE JOB. C. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONFIRMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS, FOR SELECTING FABRICATION PROCESSES, FOR TECHNIQUES OF ASSEMBLY, FOR COORDINATION OF HIS WORK WITH THAT OF OTHER TRADES AND FOR PERFORMING ALL WORK IN A SAFE AND SATISFACTORY MANNER.

4. NEW CONCRETE RAMP

CT ITE

THE GENERAL CONTRACTOR SHALL MARK LOCATIONS OF PARTITIONS AND DOORS FOR REVIEW BY THE OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. REVIEW WILL BE FOR DESIGN INTENT. SUB-CONTRACTOR SHALL COORDINATE AND VERIFY ALL CONDITIONS TO ENSURE PROPER FIT.

6. CONTRACTOR TO VERIFY FINISHES ON SIGNAGE WITH THE ARCHITECT.

N/A

DIVISION 04 - NOT USED

D. ALL TRADES SHALL PROVIDE BIDS ACCORDING TO THE PLANS AND SPECIFICATIONS. ANY ALTERNATE SHALL BE SUBMITTED TO THE OWNER (IN WRITING) FOR APPROVAL PRIOR TO ACCEPTANCE OF BID.

5. CONTRACTOR

3. NEW CONCRETE STAIR / STEP

R MO

9.

ALL INTERIOR DIMENSIONS ARE TO THE FACE OF NEW STUD, UNLESS NOTED OTHERWISE. COLUMN CENTER LINE (OR GRID LINES) ARE SHOWN FOR DIMENSIONING. VERIFY EXACT LOCATIONS IN FIELD (AS REQUIRED).

SURFACES TO BE PAINTED SHALL BE FREE OF OIL GREASE, LOOSE PAINT, OR OTHER FOREIGN MATERIAL.

N/A

ST

8.

DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN ALL PARTITION LOCATIONS. ALL DOOR AND OPENING LOCATIONS SHALL BE SHOWN ON FLOOR PLAN. IN CASE OF CONFLICT, NOTIFY THE ARCHITECT OF RECORD. FLOOR PLAN BY ARCHITECT OF RECORD SUPERSEDES OTHER PLANS. ALL DIMENSIONS MARKED "CLEAR" SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESS OF ALL FINISHES INCLUDING CARPET, PAD, CERAMIC TILE, VINYL COMPOSITE TILE, ETC.

F.

C. CONTRACTORS PRIOR TO BIDDING SHALL GUARANTEE THAT ALL OTHER SUB-BIDDEES OR SUB CONTRACTORS SHALL BE GIVEN COMPLETE FULL SETS OF PLANS TO INSURE THAT THEY HAVE INCLUDED ALL ITEMS NECESSARY TO COMPLETE THEIR WORK. ANY ITEM MISSED BY THESE SUBCONTRACTORS IN THEIR BIDS SHALL BE ABSORBED BY THE GENERAL CONTRACTOR AT HIS OR HER OWN EXPENSE AND IN NO WAY WILL AFFECT ANY ADDITIONAL COST OVER AND ABOVE THE FINAL BID.

2. ASPHALTIC CONCRETE PAVING

GENERAL CONSTRUCTION NOTES

(WHERE APPLIES) GENERAL CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL, HAULING AWAY, AND RECYCLING OF ALL DEMOLISHED ITEMS TO INCLUDE WALL PARTITIONS, CEILINGS, DOORS AND FRAMES, MILLWORK, CONVEYOR SYSTEM, FLOORING, SIGNAGE, ETC. ON-SITE DUMPSTERS ARE NOT ALLOWED TO BE USED FOR CONSTRUCTION DUMPING. (RECYCLE AND / OR SALVAGE FOR REUSE A MINIMUM OF 50% OF THE NON-HAZARDOUS CONSTRUCTION WASTE IN ACCORDANCE WITH SECTION 5.408.1.1, 5.408.1.3 OR MEET THE LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE, WHICHEVER IS MORE STRINGENT.)

THE CONTRACTOR SHALL PROTECT HIS OWN WORK, AND ADJACENT EXISTING WORK AND MATERIALS, WITH SUITABLE COVERINGS OR MASKINGS. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR CLEANING THE AREA OF HIS WORK AS WELL AS REMOVAL OF ALL EXCESS MATERIAL (EITHER FROM ADJACENT SURFACES OR EXTRA MATERIALS). CONTRACTOR TO PAINT, REPAIR OR REPLACE ANY BUILDING OR ELECTRICAL COMPONENTS DURING CONSTRUCTION AT HIS OWN EXPENSE.

B. ALL TRADES SHALL FURNISH ALL LABOR, EQUIPMENT, MATERIALS AND SERVICES REQUIRED TO PERFORM ALL WORK NECESSARY, INDICATED OR REASONABLY INFERRED OR REQUIRED BY ANY APPLICABLE CODE TO COMPLETE THEIR SCOPE OF WORK FOR A COMPLETE AND PROPERLY FINISHED JOB.

N/A

SHEET TITLE

E.

APPLICATION AND SURFACE PREPARATION SHALL BE DONE ACCORDING TO MANUFACTURER'S WRITTEN SPECIFICATIONS AND APPLICATION INSTRUCTIONS. ALL FINISHES SHALL BE APPLIED EVENLY AND BE FREE OF RUNS, SAGS, SKIPS, CRAWLS, AND / OR DEFECTS.

A. ALL BIDDERS PRIOR TO SUBMITTAL OF BIDS SHALL THOROUGHLY FAMILIARIZE THEMSELVES WITH THE ARCHITECTS' PLANS & EXISTING CONDITIONS AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCY OR OMISSIONS OF ANY INFORMATION NECESSARY FOR COMPLETION OF THEIR SCOPE OF WORK.

1. NEW CONCRETE SLAB

AS

D.

DIVISION 03 - CONCRETE

15135 NORTH FREEWAY, HOUSTON, TEXAS 77042

THE NUMBER OF COATS IS TO BE THREE (3) MINIMUM. ADDITIONAL COATS SHALL BE APPLIED AT NO ADDITIONAL COST IF NECESSARY TO COMPLETELY HIDE BASE MATERIALS, PRODUCE UNIFORM COLOR, AND PROVIDE SATISFACTORY FINISH RESULTS.

OWNER

TENANT IMPROVEMENT GARDEN CENTER SUITE #800

C.

4. BIDS

LOS ANGELES | LAS VEGAS | ATLANTA

WIL L

ACCESSORY MATERIALS SUCH AS TURPENTINE / THINNER / UNSEED OIL SHALL BE APPROVED BY THE COATING MANUFACTURER.

www.AmorArch.com

KIDS EMPIRE USA, LLC

B.

B. ALL ARCHITECT CLARIFICATIONS WILL BE WRITTEN AND / OR GRAPHIC VIA ARCHITECTURAL SUPPLEMENTAL INSTRUCTIONS, CHANGE ORDERS OR CONSTRUCTION DIRECTIVES.

P. 909.259.9971 | F. 909.944.8409

1. DEMOLITION

REG IS

5. MATERIALS A. PAINTED PRODUCTS SHALL BE MANUFACTURED BY APPROVED OR SCHEDULED PRODUCT.

11. DOORS WITH CLOSING DEVICES TO CLOSE SLOWER THAN 5 SECONDS WHEN OPEN TO 70° OR MORE.

DEMOLITION

ALL WOOD SURFACES, TRIM, OR PIECES NOT PRE-FINISHED PRIOR TO INSTALLATION. (DO NOT PAINT INTERIOR ELEMENTS NORMALLY CONCEALED SUCH AS STRUCTURAL COMPONENTS AND ELECTRICAL WIRING)

RANCHO CUCAMONGA, CA 91730

PROJECT LOCATION

10. MAXIMUM EFFORT TO OPERATED DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS. SUCH PUSH OR PULL EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATION DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED TO THE MAXIMUM ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY NOT TO EXCEED 15 POUNDS.

D.

9483 HAVEN AVE, SUITE 100

PROJECT NUMBER A2049

SHEET NUMBER

DIVISION 27 - NOT USED

LL

GC

FEDEX INSTALL

DOORS SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. WHERE NARROW FRAME DOORS ARE USED, A 10" HIGH (KICK PLATE) SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH SIDE OF THE DOOR, WHICH WILL ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION.

ALL METAL IN IMPROVED AREAS NOT PRE-FINISHED PRIOR TO INSTALLATION.

5. FINAL CLEANING

FURNISH

9.

C.

COORDINATE w/ ON-SITE OPERATION MANAGER

INSTALL

FLOOR OR LANDING SHALL BE NOT MORE THAN 1/2" LOWER THAN THE THRESHOLD OF THE DOORWAY.

ALL EXISTING WALLBOARD TO A MIN. OF 6" ABOVE ROOM CEILING. TYPICAL, UNLESS NOTED OTHERWISE ON ROOM FINISH SCHEDULE.

4. DUMPSTER

FURNISH

8.

B.

RECYCLE / NO LANDFILL

DIVISION 02 - EXISTING CONDITIONS

3. CONSTRUCTION DOCUMENTS A. THE INTENTION OF THESE DOCUMENTS IS TO INCLUDE ALL LABOR, MATERIALS, SERVICES, EQUIPMENT AND TRANSPORTATION NECESSARY FOR THE COMPLETE AND PROPER EXECUTION OF THE WORK INDICATED ON THE DRAWINGS OR REASONABLY INFERRED THESE FROM. THE ARCHITECT WILL IN NO WAY BE RESPONSIBLE FOR HOW THE FIELD WORK IS PERFORMED, SAFETY IN, OR ABOUT, THE JOB SITE METHODS OF PERFORMANCE OR TIMELINES IN THE PERFORMANCE, OF THE WORK . IF DISCREPANCIES EXIST BETWEEN PLANS OF DIFFERENT SCALES, THE LARGER SCALE PLAN TYPICALLY WILL GOVERN. NOTIFY ARCHITECT FOR A WRITTEN OR GRAPHIC CLARIFICATION OF SUCH DISCREPANCIES BEFORE PROCEEDING WITH THE WORK.

3. TRASH REMOVAL

INSTALL

THERE SHALL BE A LEVEL AND CLEAR FLOOR OR LANDING ON EACH SIDE OF A DOOR. THE LEVEL AREA SHALL HAVE A LENGTH IN THE DIRECTION OF DOOR SWING OF AT LEAST 60" (5'-0") AND THE LENGTH OPPOSITE THE DIRECTION OF DOOR SWING OF 48" (4'-0") AS MEASURED AT RIGHT ANGLE TO THE PLANE OF THE DOOR IN THE CLOSED POSITION.

4. THE FOLLOWING EXPOSED SURFACES ARE TO BE PAINTED: A. UNLESS NOTED OTHERWISE, ALL GYPSUM WALLBOARD NOT COVERED BY OTHER MATERIALS.

REMARKS

2. CERTIFICATE OF OCCUPANCY

FURNISH

7.

EVERY DOORWAY LOCATED WITHIN AN ACCESSIBLE PATH OF TRAVEL SHALL BE OF A SIZE AS TO PERMIT THE INSTALLATION OF A DOOR NOT LESS THAN 3'-0" IN WIDTH AND NOT LESS THAN 6'-8" IN HEIGHT. WHEN INSTALLED, EXIT DOORS SHALL BE CAPABLE OF OPENING SO THAT THE CLEAR WIDTH OF THE EXIT IS NOT LESS THAN 32".

C. THE GENERAL CONTRACTOR WILL BE RESPONSIBLE TO HIRE HIS / HER OWN SIGNAGE SUBCONTRACTOR FOR THE PROJECT.

2018.12.18

PERMITS & FEES PAID BY G.C.

EXISTING

6.

NEW HAND ACTIVATED DOOR OPENING HARDWARE SHALL MATCH EXISTING DOORS (WHERE APPLIES,) LEVER MUST BE CENTERED BETWEEN 34" AND 44" ABOVE THE FINISH FLOOR.

3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE OF MATERIALS AND APPLICATION WITH GOVERNING AGENCIES (LOCAL STATE AND FEDERAL) IN CONNECTION WITH THIS PROJECT.

GC

1. PERMITS, FEES & INSURANCE

NOT REQ'D

5.

LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATION BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. LOCKED EXIT DOORS SHALL OPERATE AS ABOVE IN EGRESS DIRECTION.

2. THE WORK INCLUDES, BUT IS NOT LIMITED TO FURNISHING OF MATERIALS AND EQUIPMENT, AND COMPLETION OF PAINTING AND PAINTER'S FINISH ON EXPOSED SURFACES AS REQUIRED TO COMPLETE FINISHING OF THE WORK INDICATED ON THE DRAWINGS OR SPECIFIED HEREIN.

B. THERE MAY BE INSTANCES WHERE THERE ARE OUTSTANDING PLAN CHECK FEES THAT HAVE NOT BEEN PAID. THE G.C. WILL COORDINATE WITH THE APPROPRIATE MUNICIPALITY PLANNING AND / OR BUILDING DEPARTMENT AND DETERMINE ANY OUTSTANDING FEES. THE G.C. WILL NOTIFY THE ARCHITECT AND RECEIVE APPROVAL PRIOR TO PAYING THESE OUTSTANDING FEES. THIS WILL ALLOW THE G.C. TO NOT BE DELAYED IN PULLING THE BUILDING PERMIT.

EXISTING CONDITIONS

4.

PAINTING 1. SEE FINISH SCHEDULE FOR ALL PAINT PRODUCTS AND SPECIFICATIONS.

CONCRETE

MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH BOLTS AND SURFACE BOLTS ARE PROHIBITED. WHEN EXIT DOORS ARE USED IN PAIRS AND APPROVED AUTOMATIC FLUSH BOLTS ARE USED, THE DOOR LEAF HAVING THE AUTOMATIC FLUSH BOLTS SHALL HAVE NO DOOR KNOBS OR SURFACE MOUNTED HARDWARE. THE UNLATCHING OF ANY LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION.

LL

KIDS EMPIRE

DIVISION 01 - GENERAL REQUIREMENTS

METALS

3.

A. THE GENERAL CONTRACTOR (G.C.) WILL PAY FOR ALL APPLICABLE BUILDING AND SIGNAGE PERMIT AND ANY LOCAL JURISDICTION FEES OR ASSESSMENTS AS APPLICABLE. HOWEVER, THE GENERAL CONTRACTOR SHALL INCORPORATE ALL MECHANICAL, ELECTRICAL, PLUMBING (M.E.P.) AND CIVIL PERMITS AS NECESSARY IN HIS / HER BID PROPOSAL TO THE OWNER. THE M.E.P. AND CIVIL PERMITS WILL NOT BE PAID BY THE ARCHITECT. THE G.C. WILL PHYSICALLY PULL THE BUILDING PERMIT AND THE SIGNAGE PERMIT. THE G.C. MUST COORDINATE WITH HIS / HER SUBCONTRACTORS TO ENSURE THEIR APPLICABLE PERMITS ARE PULLED. THE G.C. AND ALL SUBCONTRACTORS PERFORMING WORK ON SITE MUST OBTAIN THEIR MUNICIPALITY BUSINESS LICENSES AT THEIR EXPENSE PRIOR TO START OF CONSTRUCTION. NOT HAVING ALL SUBCONTRACTOR BUSINESS LICENSES PAID FOR AT THE MUNICIPALITY MAY PREVENT THE PROJECT FROM FINAL LOCAL JURISDICTION APPROVAL AND SIGN-OFF.

OPENINGS

EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT.

DESCRIPTION

2. PERMITS

FINISHES

2.

3. FINISHES A. UNLESS NOTED OTHERWISE (E.G. SPECIAL WALL COVERING AREAS) ALL GYPSUM WALLBOARD SHALL BE TAPED, SMOOTH, AND PAINTED. B. VERIFY ANY SPECIAL FINISH AREA PRIOR TO COMMENCING WORK.

ALL WORK SHALL CONFORM TO ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. NOTHING SHOWN IN THESE DRAWINGS SHALL BE CONSTRUED AS PERMISSION TO VIOLATE ANY GOVERNING CODES.

SPECIALTIES

ALL ENTRANCES AND ALL EXTERIOR GROUND FLOOR EXIT DOORS TO BUILDING AND FACILITIES SHALL BE MADE ACCESSIBLE OR REMAIN ACCESSIBLE.

2. ARCHITECT WILL NOT REIMBURSE CONTRACTOR OR SUB-CONTRACTOR FOR CITY OR STATE LICENSE FEES WHICH MAY BE REQUIRED TO PERFORM WORK.

1. CODES

EQUIPMENT

1.

GYPSUM WALLBOARD (WHERE APPLIES) 1. PROVIDE GYPSUM WALLBOARD, STEEL FRAMING COMPONENTS, AND ACCESSORIES ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS GYPSUM ASSOCIATION'S FIRE RESISTANCE DESIGN MANUAL. PRODUCTS SPECIFIED HEREIN ARE AS MANUFACTURED BY U.S. GYPSUM ASSOCIATION. EQUIVALENT PRODUCTS OF OTHER MANUFACTURERS WILL BE CONSIDERED PROVIDED THEY MEET THOSE ESTABLISHED STANDARDS. MAKE APPROPRIATE SUBMITTAL FOR ANY SUBSTITUTIONS.

FURNISHINGS

ENTRANCES AND EXITS

FINISHES

HVAC

(WHERE APPLIES) IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VERIFY IF THE EXISTING FIRE ALARM / BURGLAR ALARM SYSTEM NEEDS TO BE MODIFIED IN ORDER TO ACCOMMODATE THE RENOVATION SPACE. THIS INCLUDES ALL AFFECTED AREAS TO INCLUDE MAIN LOBBY AND ADJACENT ROOMS. IF REQUIRED, THE CONTRACTOR MUST SUBMIT FIRE ALARM / BURGLAR ALARM SYSTEM SHOP DRAWINGS. ALL COSTS AND FEES SHOULD BE INCLUDED IN THE CONTRACTOR'S BID PROPOSAL TO THE OWNER. AT THE COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN APPROVAL AND SIGN-OFF FOR THE MODIFIED FIRE ALARM / BURGLAR ALARM SYSTEM BY ANY JURISDICTIONAL REQUIREMENTS.

ELECTRICAL

FIRE ALARM / BURGLAR ALARM SYSTEM

RESPONSIBILITY MATRIX NOT REQ'D

GENERAL CONSTRUCTION NOTES

REMARKS

T1.2


1/2" MAX.

48-1/8" MIN (a) Front Approach

MIN (b) Side Approach

N.T.S.

(c) Pocket or Hinge Approach

15 24-1/8" MIN

(d) Stop or Latch Approach

FIGURE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND FOLDING DOORS MINIMUM MANEUVERING CLEARANCE PERPENDICULAR TO DOORWAY

FROM FRONT

PARALLEL TO DOORWAY (beyond stop/latch side unless noted)

48-1/8 INCHES

0 INCHES

42-1/8 INCHES

0 INCHES

FROM POCKET/HINGE SIDE

42-1/8 INCHES

22-1/8 INCHES

FROM STOP/LATCH SIDE

42-1/8 INCHES

24-1/8 INCHES

FROM SIDE

1. 2.

1

30-1/8" MIN. 9-7/8" MAX.

1.

2

2.

TABLE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS OR GATES, MANUAL SLIDING DOORS, AND MANUAL FOLDING DOORS

SCALE N.T.S.

2.

SPACE UNDER AN ELEMENT BETWEEN THE FINISH FLOOR OR GROUND AND 9-1/4 INCHES ABOVE THE FINISH FLOOR OR GROUND SHALL BE CONSIDERED TOE CLEARANCE AND SHALL COMPLY WITH 11B-306.2. (11B-306.2.1). SPACE UNDER AN ELEMENT BETWEEN 9-1/4 INCHES AND 27 INCHES ABOVE THE FINISH FLOOR OR GROUND SHALL BE CONSIDERED KNEE CLEARANCE AND SHALL COMPLY WITH 11B-306.3. (11B-306.3.1).

11 TOE & KNEE CLEARANCE

N.T.S.

SCALE N.T.S.

7

9-7/8" MAX.

FIGURE 11B-308.3.1 UNOBSTRUCTED SIDE REACH

23-7/8" MAX. (a)

(b)

16

WHERE A CLEAR FLOOR OR GROUND SPACE ALLOWS A PARALLEL APPROACH TO AN ELEMENT AND THE HIGH SIDE REACH IS OVER AN OBSTRUCTION, THE HEIGHT OF THE OBSTRUCTION SHALL BE 33-7/8" MAXIMUM AND THE DEPTH OF THE OBSTRUCTION SHALL BE 23-7/8" MAXIMUM. THE HIGH SIDE REACH SHALL BE 47-7/8" MAXIMUM FOR A REACH DEPTH OF 9-7/8" MAXIMUM. WHERE THE REACH DEPTH EXCEEDS 9-7/8", THE HIGH SIDE REACH SHALL BE 45-7/8" MAXIMUM FOR A REACH DEPTH OF 23-7/8" MAXIMUM. (11B-308.3.2).

SIDE REACH

SCALE N.T.S.

C COPYRIGHT 2018 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.

12

6"

60" A.F.F.

11-7/8" MAX.

11B-703.2.2 CASE CHARACTERS SHALL BE UPPERCASE.

ADA STANDARDS ACCESSIBLE DESIGN PLAN SHEET TITLE

15135 NORTH FREEWAY, HOUSTON, TEXAS 77042

TENANT IMPROVEMENT GARDEN CENTER SUITE #800

4"

KIDS EMPIRE USA, LLC

DOOR / OPENING FRAME

STRIKE SIDE EDGE OF

11B-703.2.1 DEPTH RAISED CHARACTERS SHALL BE 1/32 INCH (0.8 mm) MINIMUM ABOVE THEIR BACKGROUND.

STAMP

11B-703.2.3 STYLE CHARACTERS SHALL BE SANS SERIF. CHARACTERS SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLY DECORATIVE, OR OF OTHER UNUSUAL FORMS. 11B-703.2.5 CHARACTER HEIGHT CHARACTER HEIGHT MEASURED VERTICALLY FROM THE BASELINE OF THE CHARACTER SHALL BE 5/8 INCH MINIMUM AND 2 INCHES MAXIMUM BASED ON THE HEIGHT OF THE UPPERCASE LETTER "I". 11B-703.3 BRAILLE. BRAILLE SHALL BE CONTRACTED (GRADE 2) AND SHALL COMPLY WITH SECTIONS 11B-703.3 AND 11B-703.4. 11B-703.3.1 DIMENSIONS AND CAPITALIZATION BRAILLE DOTS SHALL HAVE A DOMED OR ROUNDED SHAPE AND SHALL COMPLY w/ TABLE 11B-703.3.1

11B-703.4.2 LOCATION WHERE A TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE LOCATED ALONGSIDE THE DOOR AT THE LATCH SIDE. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON THE INACTIVE LEAF. WHERE A TACTILE SIGN IS PROVIDE AT DOUBLE DOORS WITH TWO ACTIVE LEAFS, THE SIGN SHALL BE LOCATED TO THE RIGHT OF THE RIGHT HAND DOOR. WHERE THERE IS NO WALL SPACE AT THE LATCH SIDE OF A SINGLE DOOR OR AT THE RIGHT SIDE OF DOUBLE DOORS, SIGNS SHALL BE LOCATED ON THE NEAREST ADJACENT WALL. SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18 INCHES MINIMUM BY 18 INCHES MINIMUM, CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION. WHERE PERMANENT IDENTIFICATION SIGNAGE IS PROVIDED FOR ROOMS AND SPACES THEY SHALL BE LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE ENTERS THE ROOM OR SPACE. SIGNS THAT IDENTIFY EXITS SHALL BE LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE EXITS THE ROOM OR SPACE.

FIGURE 11B-307.2 LIMITS OF PROTRUDING OBJECTS

11-7/8" MAX.

11B-703.2 RAISED CHARACTERS. RAISED CHARACTERS SHALL COMPLY WITH SECTION 11B-703.2 AND SHALL BE DUPLICATED IN BRAILLE COMPLYING WITH SECTION 11B-703.3. RAISED CHARACTERS SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 11B-703.4.

11B-703.4.1 HEIGHT ABOVE FINISH FLOOR OR GROUND. TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST BRAILLE CELLS AND 60 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS.

FIGURE 11B-308.3.2OBSTRUCTED HIGH SIDE REACH

WHERE A CLEAR FLOOR OR GROUND SPACE ALLOWS A PARALLEL APPROACH TO AN ELEMENT AND THE SIDE REACH IS UNOBSTRUCTED, THE HIGH SIDE REACH SHALL BE 47-7/8" MAXIMUM AND THE LOW SIDE REACH SHALL BE 15-1/8" MINIMUM ABOVE THE FINISH FLOOR OR GROUND. EXCEPTION: AN OBSTRUCTION SHALL BE PERMITTED BETWEEN THE CLEAR FLOOR OR GROUND SPACE AND THE ELEMENT WHERE THE DEPTH OF THE OBSTRUCTION IS 9-7/8" MAXIMUM. (11B-308.3.1).

RAISED GRADE 2 BRAILLE: "EXIT"

11B-703.4 INSTALLATION HEIGHT AND LOCATION SIGNS WITH TACTILE CHARACTERS SHALL COMPLY WITH SECTION 11B-703.4.

4" MAX

9-7/8" MAX.

CLEAR FLOOR SPACE PARALLEL APPROACH

1.

NOTES:

DOORWAY WITH NO DOOR ONLY. BEYOND POCKET/HINGE SIDE.

ACCESSIBLE DOOR CLEARANCES

SCALE

FORWARD REACH

FIGURE 404.2.4.2

APPROACH DIRECTION

WHERE A HIGH FORWARD REACH IS OVER AN OBSTRUCTION, THE CLEAR FLOOR SPACE SHALL EXTEND BENEATH THE ELEMENT FOR A DISTANCE NOT LESS THAN THE REQUIRED REACH DEPTH OVER THE OBSTRUCTION. THE HIGH FORWARD REACH SHALL BE 47-7/8" MAXIMUM WHERE THE REACH DEPTH IS 20" MAXIMUM. WHERE THE REACH DEPTH EXCEEDS 20", THE HIGH FORWARD REACH SHALL BE 43-7/8" MAXIMUM AND THE REACH DEPTH SHALL BE 24-7/8" MAXIMUM. (11B-308.2.2).

(c) elevation @ lavatory

SYMB OL

NOTES: TACTILE EGRESS SIGNAGE (SECURE TO STOREFRONT GLASS W/ ADHESIVE). PROVIDE PLASTIC BACKING OVER OTHER SIDE OF GLASS FOR COVERAGE. ADHESIVE SHALL BE COMPATIBLE w/ GLASS APPLICATION.

RED ARCH E T M A.

AT

IA

A

16 5 9 9

AS

SCALE

2.

8-1/8" MIN. KNEE SPACE

11" MIN.

FIGURE 11B-306.3 KNEE CLEARANCE

NOTES:

E OF T EX

SHEETS BEARING THIS SEAL AND WET SIGNATURE ARE AUTHENTICATED. RESPONSIBILITY FOR ALL OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS ARE DISCLAIMED.

REVISIONS 2018-12-20

ISSUED FOR PLAN CHECK

2018-12-20

ISSUED FOR HEALTH DEPT. PLAN CHECK

11B-703.5 VISUAL CHARACTERS SHALL COMPLY WITH SECTION 11B-703.5.

26-3/4"

ACCESSIBLE DOOR CLEARANCES

(a) elevation

80-1/4" MIN. A.F.F.

NOTES: 1. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS AND GATES SHALL COMPLY w/ SECTION 11B-309.4. OPERABLE PARTS OF SUCH HARDWARE SHALL BE (CENTERED BETWEEN) 34 INCHES MINIMUM AND 44 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. (11B-404.2.7). 2. DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES MINIMUM. (11B-404.2.3).

24-7/8" MAX. (b) plan

11" MIN.

WHERE A FORWARD REACH IS UNOBSTRUCTED, THE HIGH FORWARD REACH SHALL BE 47-7/8" MAXIMUM AND THE LOW FORWARD REACH SHALL BE 15-1/8" MINIMUM ABOVE THE FINISH FLOOR OR GROUND. (11B-308.2.1).

2

WIL L

1.

N.T.S.

REG IS

NOTES:

TABLE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES

22-1/8"

FIGURE 11B-308.2.2 OBSTRUCTED HIGH FORWARD REACH

SCALE

PROJECT LOCATION

ADD 12 INCHES IF CLOSER AND LATCH ARE PROVIDED. ADD 4 INCHES IF CLOSER AND LATCH ARE PROVIDED. BEYOND HINGE SIDE. ADD 4 INCHES IF CLOSER IS PROVIDED. ADD 6 INCHES AT EXTERIOR SIDE OF EXTERIOR DOORS.

19

36-1/8" MIN 24" MIN

FIGURE 11B-308.2.1 UNOBSTRUCTED FORWARD REACH

24-1/8 INCHES

WHITE INTE RNA TIONAL OF ACCES SIBI LITY

48-1/8" MIN.

26-3/4"- 80-1/4"

4

(b)

EXIT

60" MAX. A.F.F.

44-1/8 INCHES

(a)

24-1/8 INCHES

(b) plan FIGURE 11B-306.2 TOE CLEARANCE

8-1/8" MIN. KNEE SPACE

BUILDING ENTRY SIGN

48" MIN. A.F.F.

PUSH

3

FIGURE 11B-703.7.2.1 INTERNATIONAL SYMBOL OF ACCESSIBILITY

TACTILE EXIT SIGN EXIT

9-1/4" MIN. A.F.F.

60-1/8 INCHES

22-1/8 INCHES

WHITE INTERNATIONAL SYMBOL OF ACCESSIBILITY

4"

(a)

X >12"

X >12"

80-1/4" MIN.

PULL

2

BUILDING ENTRY SIGNAGE (SECURE TO STOREFRONT GLASS W/ ADHESIVE). PROVIDE PLASTIC BACKING ON OTHER SIDE OF GLASS FOR COVERAGE. ADHESIVE SHALL BE COMPATIBLE W/ GLASS APPLICATION. BLUE BACKGROUND COLOR 15090 OF FEDERAL STANDARD NUMBER 595B

30-1/4" MIN

44-1/8 INCHES

6

17-1/8"- 24-7/8"

9-1/4" MIN. A.F.F.

PUSH

(a) elevation

6"

CL

48-1/8" MIN.

5-7/8" MAX.

27" MIN A.F.F.

36-1/8 INCHES

34" MAX.

60-1/8 INCHES

43-7/8" MAX.

PULL

1

47-7/8" MAX.

0 INCHES

1'-0"

CONSULTANT

CT ITE

N.T.S.

48-1/8 INCHES

TEST DOORS FOR DOOR OPENING FORCE AND CLOSING SPEED WITH AIR CONDITIONING AND OTHER FORMS OF MECHANICAL PRESSURIZATION TURNED ON AND ALSO WHEN TURNED OFF.

ST

SIGNS / BRAILLE

PUSH

7.

9700 WESTCHASE, LLC, A DELAWARE LIMITED LIABILITY COMPANY TENANT INTERIOR WORK

R MO

BRAILLE SHALL BE POSITIONED BELOW THE CORRESPONDING TEXT IN A HORIZONTAL FORMAT, FLUSH LEFT OR CENTERED. IF TEXT IS MULTI-LINED, BRAILLE SHALL BE PLACED BELOW THE ENTIRE TEXT. BRAILLE SHALL BE SEPARATED 3/8 INCH (9.5 MM) MINIMUM AND 1/2 INCH MAXIMUM FROM ANY OTHER TACTILE CHARACTERS AND 3/8 INCH (9.5 MM) MINIMUM FROM RAISED BORDERS AND DECORATIVE ELEMENTS. (11B-703.3.2).

FROM FRONT FROM HINGE SIDE FROM HINGE SIDE FROM LATCH SIDE FROM LATCH SIDE

45-7/8" MAX.

BRAILLE DOTS SHALL HAVE A DOMED OR ROUNDED SHAPE AND SHALL COMPLY WITH TABLE 11B-703.3.1. THE INDICATION OF AN UPPERCASE LETTER OR LETTERS SHALL ONLY BE USED BEFORE THE FIRST WORD OF SENTENCES, PROPER NOUNS AND NAMES, INDIVIDUAL LETTERS OF THE ALPHABET, INITIALS, AND ACRONYMS. (11B-703.3.1).

18-1/8 INCHES

THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR OR GATE IN A CLOSED POSITION. (11B-404.2.9).

POWER-OPERATED DOORS. WHERE MEANS OF EGRESS DOORS ARE OPERATED OR ASSISTED BY POWER, THE DESIGN SHALL BE SUCH THAT IN THE EVENT OF POWER FAILURE, THE DOOR IS CAPABLE OF BEING OPENED MANUALLY TO PERMIT MEANS OF EGRESS TRAVEL OR CLOSED WHERE NECESSARY TO SAFEGUARD MEANS OF EGRESS. THE FORCES REQUIRED TO OPEN THESE DOORS MANUALLY SHALL NOT EXCEED THOSE SPECIFIED IN SECTION 1010.1.3, EXCEPT THAT THE FORCE TO SET THE DOOR IN MOTION SHALL NOT EXCEED 50 POUNDS (220 N). THE DOOR SHALL BE CAPABLE OF SWINGING OPEN FROM ANY POSITION TO THE FULL WIDTH OF THE OPENING IN WHICH SUCH DOOR IS INSTALLED WHEN A FORCE IS APPLIED TO THE DOOR ON THE SIDE FROM WHICH EGRESS IS MADE. POWER-OPERATED SWINGING DOORS, POWER-OPERATED SLIDING DOORS AND POWER-OPERATED FOLDING DOORS SHALL COMPLY WITH BHMA A156.10. POWER-ASSISTED SWINGING DOORS AND LOW-ENERGY POWER-OPERATED SWINGING DOORS SHALL COMPLY WITH BHMA A156.19. (1010.1.4.2).

THE TURNING SPACE SHALL BE A T-SHAPED SPACE WITHIN A 60-1/8" SQUARE MINIMUM WITH ARMS AND BASE 36-1/8" WIDE MINIMUM. EACH ARM OF THE T SHALL BE CLEAR OF OBSTRUCTIONS 12" MINIMUM IN EACH DIRECTION AND THE BASE SHALL BE CLEAR OF OBSTRUCTIONS 24" MINIMUM. THE SPACE SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 11B-306 ONLY AT THE END OF EITHER THE BASE OR ONE ARM. (11B-304.3.2).

>20"-24-7/8" MAX.

OWNER

6.

3.

N.T.S.

LOS ANGELES | LAS VEGAS | ATLANTA

4. EXTERIOR HINGED DOORS: 5 POUNDS (22.2 N) MAXIMUM.

ALCOVES SHALL BE 60-1/4" WIDE MINIMUM WHERE THE DEPTH EXCEEDS 15 INCHES. (11B-305.7.2).

SCALE

www.AmorArch.com

2. SLIDING OR FOLDING DOORS: 5 POUNDS (22.2 N) MAXIMUM.

FIGURE 11B-304.3.2 T-SHAPED TURNING SPACE

CLEAR FLOOR & TURNING SPACE

P. 909.259.9971 | F. 909.944.8409

3. REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS (66.7 N).

2.

10

N.T.S.

33-7/8" MAX

2.

60-1/8 INCHES

1. 2. 3. 4. 5.

SCALE

47-7/8" MAX.

BRAILLE SHALL BE CONTRACTED (GRADE 2) AND SHALL COMPLY WITH SECTIONS 11B-703.3 AND 11B-703.4. (11B-703.3).

PULL

20" MAX.

33-7/8" MAX.

1.

FROM FRONT

5

47-7/8" MAX.

FIGURE 703.3.1 BRAILLE MEASUREMENT

PARALLEL TO DOORWAY (beyond latch side unless noted)

48-1/8" MIN.

NO RAISED DOT

PERPENDICULAR TO DOORWAY

42-1/8" MIN

BASE DIAMETER

DOOR SIDE

42-1/8" MIN

RAISED DOT

APPROACH DIRECTION

WIDTH OF ACCESSIBLE ROUTE

RANCHO CUCAMONGA, CA 91730

1. INTERIOR HINGED DOORS AND GATES: 5 POUNDS (22.2 N) MAXIMUM.

ALCOVES SHALL BE 36-1/4" WIDE MINIMUM WHERE THE DEPTH EXCEEDS 24 INCHES. (11B-305.7.1).

MINIMUM MANEUVERING CLEARANCE

42-1/8" MIN

BLANK CELL SPACE BETWEEN WORDS

SCALE

AN ACCESSIBLE ROUTE WITH A CLEAR WIDTH LESS THAN 60 INCHES SHALL PROVIDE PASSING SPACES AT INTERVALS OF 200 FEET MAXIMUM. PASSING SPACES SHALL BE EITHER: A SPACE 60 INCHES MINIMUM BY 60 INCHES MINIMUM; OR , AN INTERSECTION OF TWO WALKING SURFACES PROVIDING A T-SHAPED SPACE COMPLYING WITH SECTION 11B-304.2 WHERE THE BASE AND ARMS OF THE T-SHAPED SPACE EXTEND 48 INCHES MINIMUM BEYOND THE INTERSECTION. (11B-403.5.3).

15-1/8" MIN.

TYPE OF USE

1.

9483 HAVEN AVE, SUITE 100

THE FORCE FOR PUSHING OR PULLING A DOOR OR GATE OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS:

5

27" MIN A.F.F.

FIGURE 11B-404.2.4.3 MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES

DISTANCE BETWEEN CORRESPONDING DOTS FROM ONE CELL DIRECTLY BELOW

2.

DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION 12 DEGREES FROM THE LATCH IS 5 SECONDS MINIMUM. (11B-404.2.8.1).

12" 36-1/8" 12" MIN MIN MIN

*NOTE: IF GREATER THAN 15", THEN ADD 12" (60-1/4" MIN.)

9-1/4" MIN. A.F.F.

48-1/8" MIN

X > 8"

(c) Push Side, Door provided with both closer and latch

FIGURE 11B-403.5.2 CLEAR WIDTH AT TURN

5.

60-1/8" MIN

FIGURE 11B-305.7.1 AND 305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE NOTES:

(b) 180 DEGREE TURN (EXCEPTION)

15-1/8" MIN.

DISTANCE BETWEEN DOTS IN THE SAME CELL

Plotted: 12/20/2018 1:12 PM (jlavenant) File: 03_a2049_t1.3_ada standards.dwg

12-1/8" MIN

36-1/4" MIN

4.

48-1/4" MIN.

*NOTE: IF GREATER THAN 24", THEN ADD 12" (36-1/4" MIN.)

THE MINIMUM WIDTH OF EXIT PASSAGEWAYS SHALL BE DETERMINED AS SPECIFIED IN SECTION 1005.1 BUT SUCH WIDTH SHALL NOT BE LESS THAN 44 INCHES, EXCEPT THAT EXIT PASSAGEWAYS SERVING AN OCCUPANT LOAD OF LESS THAN 50 SHALL NOT BE LESS THAN 36 INCHES IN WIDTH. THE REQUIRED WIDTH OF EXIT PASSAGEWAYS SHALL BE UNOBSTRUCTED. (11B-1023.2).

(a) Pull Side (b) Push Side

36-1/4" MIN X < 48"

47-7/8" MAX.

DISTANCE BETWEEN DOTS IN THE SAME CELL SINGLE BRAILLE CELL

3.

NOTES:

24-1/8" MIN AT EXTERIOR 48-1/8" MIN

TABLE 11B-703.3.1 BRAILLE DIMENSIONS

N.T.S.

WHEELCHAIR CLEARANCE SPACE IS 30-1/8" MIN. X 48-1/8" MIN.

42-1/4" MIN X < 48"

(a) 180 DEGREE TURN

1.

X > 8"

MEASURED CENTER TO CENTER

DISTANCE BETWEEN CORRESPONDING DOTS IN ADJACENT CELLS

(k) Latch Approach, Push Side Door provided with closer

18-1/8" MIN AT INTERIOR

X > 8"

1.

42-1/4" MIN

FIGURE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES

60-1/8" MIN

DISTANCE BETWEEN CORRESPONDING DOTS FROM ONE CELL DIRECTLY BELOW 1

SCALE

MIN

(j) Latch Approach, Push Side

0.025 TO 0.037 0.395 TO 0.400

ALL NEW CONSTRUCTION MUST COMPLY WITH DIMENSIONS AS DENOTED ON THESE CONSTRUCTION DOCUMENTS AND WITH CHAPTER 11B OF THE 2016 CBC. DIMENSIONS WITHIN A SPECIFIED DIMENSIONAL "RANGE" MUST BE LESS-THAN THE MAXIMUM DIMENSIONAL RANGE OR GREATER THAN THE MINIMUM DIMENSIONAL RANGE. IN OTHER WORDS, NEW CONSTRUCTION SHALL NOT BE EQUAL TO EITHER THE MAXIMUM OR MINIMUM DIMENSIONS, BUT SHALL BE LESS THAN THE MAXIMUM AND GREATER THAN THE MINIMUM. MAXIMUM SLOPES FOR NEW RAMPS SHALL BE ONE (1) VERTICAL TO 13 HORIZONTAL MAXIMUM. DESIGN INTENT OF ARCHITECT IS TO PROVIDE REASONABLE DIMENSIONAL TOLERANCES, ENSURE COMPLIANCE WITH THE ADA, AND TO SIMPLIFY AND EXPEDITE THE CONSTRUCTION PROCESS. CONTRACTOR SHALL BE HELD FULLY RESPONSIBLE FOR NON-COMPLIANCE WITH THIS NOTICE. CONTRACTOR TO NOTIFY ARCHITECT PRIOR TO BIDDING OF ANY QUESTIONS OR CONCERNS RELATING TO THIS MATTER.

60-1/8" MIN

9

N.T.S.

*15" OR LESS

48-1/4" MIN

FLOOR / GROUND SURFACE 30-1/8"

24-1/8"

SCALE

30-1/4" MIN.

DOT HEIGHT

3.

CHANGES IN LEVEL BETWEEN 1/4" HIGH MINIMUM AND 1/2" HIGH MAXIMUM SHALL BE BEVELED WITH A SLOPE NOT STEEPER THAN 1:2. (11B-303.3).

29" MIN.

MIN

OPENINGS IN FLOOR OR GROUND SURFACES SHALL NOT ALLOW PASSAGE OF A SPHERE MORE THAN 1/2 INCH DIAMETER EXCEPT AS ALLOWED IN SECTIONS 11B-407.4.3, 11B-409.4.3, 11B-410.4, 11B-810.5.3 AND 11B-810.10. ELONGATED OPENINGS SHALL BE PLACED SO THAT THE LONG DIMENSION IS PERPENDICULAR TO THE DOMINANT DIRECTION OF TRAVEL. (11B-302.3).

BEVELED CHANGE IN LEVEL

30-1/4" MIN

0.300

24-1/8"

2

WHEN HIGHER THAN 26-3/4"

DISTANCE BETWEEN CORRESPONDING DOTS IN ADJACENT CELLS 1

(h) Latch Approach, Pull Side

MIN

0.100

MIN

48-1/8"

DISTANCE BETWEEN TWO DOTS IN THE SAME CELL 1

CLEAR WIDTH AT ROUTE / TURN

24-1/8"

MIN

0.059 TO 0.063

2.

CHANGES IN LEVEL OF 1/4" HIGH MAXIMUM SHALL BE PERMITTED TO BE VERTICAL AND WITHOUT EDGE TREATMENT. (11B-303.2).

3.

(g) Hinge Approach, Push Side, Door provided with both closer and latch

MINIMUM IN INCHES MAXIMUM IN INCHES

DOT BASE DIAMETER

60-1/8" MIN

17

2.

*24" OR LESS

N.T.S.

1

CARPET OR CARPET TILE SHALL BE SECURELY ATTACHED AND SHALL HAVE A FIRM CUSHION, PAD, OR BACKING OR NO CUSHION OR PAD. CARPET OR CARPET TILE SHALL HAVE A LEVEL LOOP, TEXTURED LOOP, LEVEL CUT PILE, OR LEVEL CUT/UNCUT PILE TEXTURE. PILE HEIGHT SHALL BE 1/2" MAXIMUM. EXPOSED EDGES OF CARPET SHALL BE FASTENED TO FLOOR SURFACES AND SHALL HAVE TRIM ON THE ENTIRE LENGTH OF THE EXPOSED EDGE. CARPET EDGE TRIM SHALL COMPLY WITH SECTION 11B-303. (11B-302.2).

NOTE: 1. THE CLEAR WIDTH SHALL BE PERMITTED TO BE REDUCED TO 32-1/4" MINIMUM FOR A LENGTH OF 23-3/4" MAXIMUM PROVIDED THAT REDUCED WIDTH SEGMENTS ARE SEPARATED BY SEGMENTS THAT ARE 48-1/4" LONG MINIMUM AND 36-1/4" WIDE MINIMUM. (11B-403.5.1 EXCEPTION 1).

60-1/4" MIN

SCALE

22-1/8" MIN

44-1/8"

ACCESSIBLE DOORS IN A SERIES

48-1/8" MIN

NOTE: 1. THE DISTANCE BETWEEN TWO HINGED OR PIVOTED DOORS IN SERIES AND GATES IN SERIES SHALL BE 48 INCHES MINIMUM PLUS THE WIDTH OF DOORS OR GATES SWINGING INTO THE SPACE. (11B-404.2.6).

1/4" MAX. 1.

22-1/8" MIN

(f) Hinge Approach, Push Side

FIGURE 11B-404.2.6 DOORS IN SERIES AND GATES IN SERIES

MEASUREMENT RANGE

FIGURE 11B-403.5.1 CLEAR WIDTH OF AN ACCESSIBLE ROUTE

(d) Hinge Approach, Pull Side

(c)

GROUND AND FLOOR SURFACES ALONG ACCESSIBLE ROUTES AND IN ACCESSIBLE ROOMS AND SPACES INCLUDING FLOORS, WALKS, RAMPS, STAIRS AND CURB RAMPS SHALL BE STABLE, FIRM AND SLIP RESISTANT.

NOTES:

44-1/8" MIN

60-1/8" MIN

MIN

1.

VERTICAL CHANGE IN LEVEL 1/4" MAX.

(c) Front Approach, Push Side Door provided with closer and latch

48-1/8" MIN

36-1/8"

23-3/4" 48-1/4" MIN 23-3/4" MAX CLEAR MAX

1/4" MAX.

(b) Front Approach, Push Side

ACCESSIBILITY NOTES CARPET PILE HEIGHT

1/2" MAX.

12-1/8" MIN

32-1/4" MIN CLR

(a) Front Approach, Pull Side

48-1/8" MIN

MIN

36-1/4" MIN CLR

(b)

48-1/8" MIN

48-1/8" MIN.

(a)

Add 6 inches at exterior side of exterior door 18-1/8"

60-1/8" MIN

48-1/8" MIN.

(b)

11B-703.6 PICTOGRAMS PICTOGRAMS SHALL COMPLY WITH SECTION 11B-703.6. 11B-703.6.1 PICTOGRAM FIELD PICTOGRAMS SHALL HAVE A FIELD HEIGHT OF 6 INCHES MINIMUM. CHARACTERS AND BRAILLE SHALL NOT BE LOCATED IN THE PICTOGRAM FIELD.

FIGURE 11B-307.3 POST-MOUNTED PROTRUDING OBJECTS

PROTRUDING OBJECTS

11B-703.5.1 FINISH AND CONTRAST CHARACTERS AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH. CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND WITH EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND.

SCALE N.T.S.

8

BUILDING EXIT SIGN

SCALE N.T.S.

4

DATE 2018.11.28 PROJECT NUMBER A2049

SHEET NUMBER

T1.3


9

8

7

TODDLER ZONE 107

1

1

6

5

DANCE ROOM 108

1

4

3

2

OCCUPANT LOAD

1

OPEN SEATING AREA 109

OCCUPANT LOAD PER 2015 IBC TABLE 1004.1.2 ROOM #

FUNCTION OF SPACE PER TABLE 1004.1.2

SQ. FT.

ROOM NAME

A 79'

EXIT 75

101 102 103 104 105 106 107 108 109 110 111 112

F.E.

PICNIC TABLE

PICNIC TABLE

ENTRANCE/LOBBY BAR AREA PANTRY AREA VESTIBULE EXIST. WOMEN'S TOILET ROOM EXIST. MEN'S TOILET ROOM TODDLER ZONE DANCE ROOM OPEN SEATING AREA PLAY EQUIPMENT AREA OPEN SEATING AREA OPEN SEATING AREA

TOTAL W/ ACCESSORY USE TOTAL W/ BUSINESS USE TOTAL USE

EXIST. MEN'S TOILET ROOM 106

ACCESSORY USE BUSINESS USE BUSINESS USE ACCESSORY USE 800 SQ. FT 253 SQ. FT. ACCESSORY USE 176 SQ. FT. ACCESSORY USE 3,196 SQ. FT. ACCESSORY USE 540 SQ. FT. ACCESSORY USE 1,344 SQ. FT. ACCESSORY USE 224 SQ. FT 282 SQ. FT. 243 SQ. FT. -

2,284 SQ. FT. 525 SQ. FT. 2,585 SQ. FT.

OCCUPANT LOAD FACTOR TABLE 1004.1.1 15 15 15 15 15 15

I.B.C. OCC. LOAD 15 19 16 0 0 0 0 0 12 0 36 90 153 35 188

9483 HAVEN AVE, SUITE 100 RANCHO CUCAMONGA, CA 91730 P. 909.259.9971 | F. 909.944.8409 www.AmorArch.com LOS ANGELES | LAS VEGAS | ATLANTA

OWNER

N.I.C.

LEGEND

EXIST. VESTIBULE 104

9700 WESTCHASE, LLC, A DELAWARE LIMITED LIABILITY COMPANY TENANT INTERIOR WORK

B # EXIST. WOMEN'S TOILET ROOM 105

NUMBER OF PEOPLE EXITING

F.E. PLAY EQUIPMENT AREA 110

+34"

PANTRY AREA 103

34" CASHIER COUNTER

N.I.C.

PATH OF TRAVEL (200 FEET MAXIMUM TRAVEL DISTANCE WITH NO SPRINKLER SYSTEM) PER 2013 CBC TABLE 1016.2

OPEN SEATING AREA 112

F.E.

FIRE EXTINGUISHERS - NOTE #7 ON SHEET A1.1 AND NOTE #18 ON SHEET T1.1. CONSULTANT

BAR AREA

KEY NOTES

34" CASHIER COUNTER

102

EXISTING BUILDING EXIT DOOR TO BE BLOCKED (NOT TO BE USED AS EXIT)

PICNIC TABLE

PICNIC TABLE

PICNIC TABLE

PICNIC TABLE

PICNIC TABLE

F.E.

75

EXIT

ENTRANCE

LOBBY

D

PROJECT LOCATION

101

C

OPEN SEATING AREA 111

TENANT IMPROVEMENT GARDEN CENTER SUITE #800

KIDS EMPIRE USA, LLC

F.E.

140'

+34" CASHIER COUNTER

EGRESS PLAN

PICNIC TABLE

SHEET TITLE

+34"

15135 NORTH FREEWAY, HOUSTON, TEXAS 77042

+34"

+36" DISPLAY CASE

+34"

+34"

1

A

16 5 9 9

AS

W IL L

ST

AT

IA

CT ITE

RED ARCH E T M A. R MO

REGI S

STAMP

E OF T EX

Plotted: 12/20/2018 1:13 PM (jlavenant) File: 04_a2049_t1.4_egress plan.dwg

SHEETS BEARING THIS SEAL AND WET SIGNATURE ARE AUTHENTICATED. RESPONSIBILITY FOR ALL OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS ARE DISCLAIMED.

REVISIONS 2018-12-20

ISSUED FOR PLAN CHECK

2018-12-20

ISSUED FOR HEALTH DEPT. PLAN CHECK

DATE 2018.11.28 PROJECT NUMBER A2049

N

EGRESS PLAN C COPYRIGHT 2018 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.

SCALE 1/8" = 1'-0"

1

SHEET NUMBER

T1.4


14

1

5

1

1

9483 HAVEN AVE, SUITE 100 RANCHO CUCAMONGA, CA 91730

1 1

P. 909.259.9971 | F. 909.944.8409

5

www.AmorArch.com

1 1

5

1

1

5

6

1

5

LOS ANGELES | LAS VEGAS | ATLANTA

OWNER

1 9700 WESTCHASE, LLC, A DELAWARE LIMITED LIABILITY COMPANY TENANT INTERIOR WORK

(E) ACCESSIBLE PARKING 1 ENTRY

26

CONSULTANT

2

1

32

1

22

1

22

25

1 1

1 1

32

1

27

PROJECT LOCATION

30

1

STAMP

WIL L

9

1

9

1

Plotted: 12/20/2018 1:14 PM (jlavenant) File: 05_a2049_as1.1_site plan.dwg

21

2

EXISTING 4' - 8" WIDE PATH OF TRAVEL TO REMAIN.

EXISTING ADA PATH OF TRAVEL. EXISTING CONSIST OF NO STEPS AND IS SLIP RESISTANT.

1

17 1

9

1

9

AT

A

16 5 9 9

E OF T EX

EXISTING ACCESSIBLE PARKING AND PATH OF TRAVEL, LESS THAN 2% SLOPES.

LEGEND 61

ST

1 1

REFERENCED NOTES

13

IA

R MO

REG IS

RED ARCH E T M A.

CT ITE

27

1

TENANT IMPROVEMENT GARDEN CENTER SUITE #800

1

KIDS EMPIRE USA, LLC

34

EXISTING SITE PLAN (FOR REFERENCE ONLY)

30

1

SHEET TITLE

1 A1.1

AS

17

15135 NORTH FREEWAY, HOUSTON, TEXAS 77042

KIDS EMPIRE ± 9,318 S.F.

SHEETS BEARING THIS SEAL AND WET SIGNATURE ARE AUTHENTICATED. RESPONSIBILITY FOR ALL OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS ARE DISCLAIMED.

REVISIONS 2018-12-20

ISSUED FOR PLAN CHECK

2018-12-20

ISSUED FOR HEALTH DEPT. PLAN CHECK

4 35 1

PARKING SUMMARY

11

N

EXISTING SITE PLAN - (FOR REFERENCE ONLY) C COPYRIGHT 2018 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.

SCALE 3/32" = 1'-0"

1

EXISTING PARKING SUMMARY ON - SITE PARKING EXISTING PARKING STALLS: 656 STANDARD PARKING STALLS 11 STANDARD ACCESSIBLE STALLS 1 VAN ACCESSIBLE STALLS 671 SPACES TOTAL

DATE 2018.11.28 PROJECT NUMBER A2049

SHEET NUMBER

AS1.1


DEMOLITION - GENERAL NOTES

LEGEND - DEMO

CODES AND STANDARDS:

(E) CPE METER

EP

EP

W/H

(E )

(E )

EP (E )

EP (E )

(E )

EP

A

7 6 TYP.

TYP.

M.S.

7

DEMO UNDER SEPARATE PERMIT

6

TYP.

6 TYP.

7

13 TYP.

10

11

8

TYP.

12 TYP.

13 TYP.

8 TYP.

9

9

TYP.

TYP.

5 TYP.

SITE INVESTIGATION: 3. THE G.C. SHALL VISIT THE SITE TO DETERMINE THE FULL EXTENT OF ALL THE WORK AND ANY OTHER MATTERS THAT, IN ANY WAY, MAY AFFECT THE WORK. FAILURE OF THE G.C. TO FAMILIARIZE HIMSELF WITH ALL AVAILABLE INFORMATION CONCERNING CONDITIONS WILL NOT RELIEVE HIM FROM FULL RESPONSIBILITY FOR ANY EXCESS IN THE COST OF THE WORK. IMMEDIATELY UPON COMPLETION OF DEMOLITION, ALL CONDITIONS AND DIMENSIONS ARE TO BE CHECKED FOR DISCREPANCIES. REPORT ANY DISCREPANCIES IMMEDIATELY TO THE ARCHITECT. ANY UNNOTED EXISTING CONDITIONS WHICH MAY CONFLICT WITH THE PROPOSED OF NEW WORK AND MAY REQUIRE MODIFICATION, RE-LOCATION OR REMOVAL SHALL BE IDENTIFIED AND REPORTED TO THE ARCHITECT IMMEDIATELY. DEMOLITION: 4. UNLESS NOTED OTHERWISE, NO ALTERATION OF THE LANDLORD's BUILDING STRUCTURE IS ALLOWED. OPERATIONAL PROCEDURES SHALL BE OPTIONAL AT THE G.C.'s DISCRETION AS LONG AS THE PROCEDURES DO NOT DELAY THE APPROVED WORK SCHEDULE OR COMPROMISE SALVAGE REQUIREMENTS. 5.

DEMO UNDER SEPARATE PERMIT 6.

7. B

8.

15

4

15

9.

2

D 1

15. RE-USE EXISTING ELECTRICAL DEVICES, OUTLETS, TELEPHONE AND DATA JACKS AND THERMOSTATS: MODIFY EXISTING WIRING AS REQUIRED BY NEW CONSTRUCTION OR, IF NOT REQUIRED, TERMINATE AND CAP OFF AT NEAREST PANEL OR SOURCE ABOVE CEILING.

3

CLEAN UP: 16. GENERAL CONTRACTOR SHALL LEAVE THE AREA OF WORK AND AREAS AFFECTED BY WORK IN A CLEAN CONDITION, SATISFACTORY TO LOCAL AUTHORITIES AND THE ARCHITECT. WHERE APPLICABLE, THE G.C. SHALL REPAIR ANY ADJACENT TENANT WALL, LOBBY FLOORING, ETC., TO THE SATISFACTION OF INVOLVED PARTIES DAMAGED BY THE DEMOLITION OR CONSTRUCTION PROCESS.

PS

(E) FIRE ALARM PULL STATION

P. 909.259.9971 | F. 909.944.8409

A

(E) FIRE ALARM (E) SECURITY ALARM KEYPAD

LOS ANGELES | LAS VEGAS | ATLANTA

F

SP

S

(E) SPEAKER

C

M

M

(E) MOTION DETECTOR (E) FIRE EXTINGUISHER (E) F. E. CABINET (RECESSED)

9483 HAVEN AVE, SUITE 100

www.AmorArch.com

OWNER

(E) FIRE STROBE LIGHT

C

(E) SECURITY CAMERA

T

(E) THERMOSTAT TO REMAIN. U.N.O.

SD

SM

(E) SMOKE DETECTOR

(E) 2-GANG DATA BLACK BOX (E) PHONE JACK

(E) DUPLEX RECEPTACLE (E) QUAD OUTLET

(E) WALL-MOUNTED ADA PUSH PLATE

(E) SWITCH

9700 WESTCHASE, LLC, A DELAWARE LIMITED LIABILITY COMPANY TENANT INTERIOR WORK

CONSULTANT

REFER TO THE SCOPE OF NEW WORK IN THE DRAWINGS FOR ANY EQUIPMENT, DUCTWORK, REGISTERS, ETC. ENCOUNTERED DURING DEMOLITION NOT SHOWN ON THESE PLANS. NOTIFY ARCHITECT OF ANY ABANDONED AND / OR NOT USED EQUIPMENT, FIXTURES, DUCTWORK, REGISTERS, ETC.

14. CAREFULLY REMOVE AND RE-INSTALL ALL EXISTING SPEAKERS, CAMERA DEVICES AND EQUIPMENT AND SAVE FOR RE-INSTALLATION. EXISTING SYSTEM TO REMAIN OPERATIONAL THROUGHOUT THE CONSTRUCTION.

(E) EMERGENCY LIGHT FIXTURE w/ EXIT SIGN TO REMAIN. U.N.O.

(E) FIRE SPRINKLER HEAD TO REMAIN. U.N.O.

REMOVE ALL FLOOR FINISHES AS SCHEDULED FOR REMOVAL, PREPARE FLOOR FOR INSTALLATION OF NEW FLOORING MATERIAL PER MANUFACTURERS' RECOMMENDATIONS. G.C. MAY NEED TO PERFORM A MOISTURE TEST PRIOR TO ANY DEMOLITION / NEW FLOORING INSTALLATION WHERE REQUIRE.

13. EXISTING SERVICES THAT WILL BE DISRUPTED BY CONSTRUCTION WORK SHALL BE RE-ROUTED AS NECESSARY TO PROVIDE TEMPORARY CONTINUATION OF SERVICE. DISCONNECTED SERVICES SHALL BE PLUGGED AND SEALED IN SAFE AND APPROVED MANNER.

(E) TRANSFER DIFFUSER TO REMAIN

(E) ILLUMINATED EXIT SIGN TO REMAIN. U.N.O.

EXIT

REMOVE ALL EXISTING INTERIOR PARTITIONS, DOORS AND DOOR FRAMES DENOTED FOR DEMOLITION. REMOVE ALL MILLWORK, EQUIPMENT, ETC. ATTACHED TO PARTITIONS SCHEDULED FOR DEMOLITION.

DISCONNECTION OF SERVICES: 12. G.C. TO COORDINATE WITH KID EMPIRE VENDORS TO DISCONNECT AND RECONNECT ALL COMPUTER AND PHONE HARDWARE.

C

EXIT

GENERAL CONTRACTOR SHALL NOT DEMOLISH ANY LOAD BEARING WALLS AND CONSTRUCTION THAT WILL COMPROMISE THE FULL STRUCTURAL INTEGRITY OF THE EXISTING SPACE AND BUILDING. G.C. IS RESPONSIBLE TO NOTIFY ARCHITECT IMMEDIATELY OF ANY STRUCTURAL CONCERNS DURING DEMOLITION AND CONSTRUCTION.

11. REPLACE OR RE-LOCATE, IN ACCORDANCE WITH LOCAL CODES, ALL FIRE SUPPRESSION AND FIRE ALARM EQUIPMENT DISTURBED BY DEMOLITION WORK. MAINTAIN INTEGRITY OF FIRE SUPPRESSION AND FIRE ALARM SYSTEM.

(E) EMERGENCY LIGHT FIXTURE TO REMAIN. U.N.O.

RANCHO CUCAMONGA, CA 91730

COORDINATE ANY DEMOLITION REQUIREMENTS AND PROVISIONS WITH THE ARCHITECT PRIOR TO BEGINNING ANY WORK. NOTIFY THE ARCHITECT IMMEDIATELY IF ANY UNFORESEEN HAZARDS ARE DISCOVERED PRIOR TO COMPLETION OF DEMOLITION.

10. REMOVE AND DISPOSE OF ALL FIXTURES AND HANGING RAILS UNLESS NOTED TO BE RE-USED. SEE NEW FIXTURE PLAN AND NEW REFLECTED CEILING PLAN FOR ALL EXISTING FIXTURES AND DEVICES DENOTED TO BE RE-USED AND RE-LOCATED.

(E) WALL SCONCE / LIGHT

(E) DOOR TO BE REMOVED

(E) DOOR TO REMAIN

(E) WALL TO BE REMOVED

(E) EXTERIOR WALL TO REMAIN

(E) FIXTURE TO BE REMOVED / RE-LOCATED

(E) INTERIOR PARTITION TO REMAIN

DEMOLITION - KEY NOTES 1

(E) PAIR ENTRY DOORS AT BUILDING STOREFRONT TO BE REMOVED.

2

(E) PORTION OF BUILDING STOREFRONT TO BE REMOVED. SEE NEW CONSTRUCTION FLOOR PLAN FOR ADDITIONAL INFORMATION.

3

(E) SINGLE ENTRY DOOR AT BUILDING STOREFRONT TO BE REMOVED.

4

(E) FULL-HEIGHT GYP. BRD. DEMISING PARTITION TO BE REMOVED.

5

(E) FULL-HEIGHT GYP. BD. PARTITION TO BE REMOVED.

6

(E) ELECTRICAL SUB-PANELS TO BE REMOVED. SEE ELECTRICAL ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION.

7

(E) BUILDING GYP. BRD. WALL FURRING TO BE REMOVED.

8

REMOVE (E) DOOR AND FRAME.

9

(E) GYP. BRD. PARTITION TO BE REMOVED.

10

(E) WATER HEATER TO BE REMOVED.

11

(E) MOP SINK TO BE REMOVED.

12

(E) MILLWORK COUNTER TOP AND SINK TO BE REMOVED.

13

(E) PLUMBING FIXTURE TO BE REMOVED.

14

(E) FULL-HEIGHT GYP. BRD. DEMISING PARTITION TO REMAIN.

STAMP

WIL L

A

R MO

AT

IA

CT ITE

RED ARCH E T M A.

ST

19. PROVIDE A SMOOTH, NEAT, CONTINUOUS APPEARANCE WHERE DEMO WORK MEETS ADJACENT (E) WORK. REMOVE (E) FINISHES AS REQUIRED TO PROVIDE NEAT, STRAIGHT SEAMS AND TRANSITIONS BETWEEN (E) AND MATCHING NEW FINISHES. PREPARE (E) FLOORS, WALLS, AND CEILING ELEMENTS AS REQUIRED FOR NEW FINISHES.

REG IS

17. PROVIDE TRASH CONTAINER AS REQUIRED AT LOCATION TO SUIT KIDS EMPRE's REQUIREMENT. REMOVE DEBRIS DAILY AND HAUL AWAY FROM THE SITE AT TIME CONVENIENT TO KID EMPIRE. 18. ALL REMOVED MATERIALS, NOT OTHERWISE DESIGNATED, AND ALL DEBRIS BECOME THE PROPERTY OF THE CONTRACTOR, WHO SHALL REMOVE THEM FROM THE SITE AND SALVAGE / RECYCLE ACCORDING TO KIDS EMPIRE's PROTOCOL.

DEMOLITION- FLOOR PLAN

1

SHEET TITLE

2

16 5 9 9

AS

3

15135 NORTH FREEWAY, HOUSTON, TEXAS 77042

4

(E) SUPPLY / RETURN AIR DIFFUSER TO REMAIN

TENANT IMPROVEMENT GARDEN CENTER SUITE #800

5

(E) RECESSED CAN LIGHT / DOWNLIGHT

KIDS EMPIRE USA, LLC

6

GENERAL CONTRACTOR (G.C.) SHALL PROCURE ALL CITY AND STATE PERMITS AND LICENSES AND PAY ALL CHARGES AND FEES UNLESS SPECIFIED OTHERWISE.

(E) SUPPLY / RETURN AIR DIFFUSER TO BE RE-LOCATED

PROJECT LOCATION

7

2.

(E) TRACK LIGHT - CEILING MOUNTED TO BE REMOVED

T

8

DEMOLITION WORK SHALL BE CONDUCTED IN ACCORDANCE WITH THE LANDLORD, CITY, STATE AND FEDERAL SAFETY REQUIREMENTS.

3

9

1.

(E) SUSPENDED CEILING GRID TO REMAIN. (U.N.O.) ACOUSTICAL TILE TO BE REMOVED

(E) FLUORESCENT LIGHT CEILING MOUNTED TO BE REMOVED

SEE SHEET T1.2 FOR GENERAL CONSTRUCTION NOTES

E OF T EX

Plotted: 12/20/2018 1:14 PM (jlavenant) File: 06_a2049_ad1.1_demo plan.dwg

SHEETS BEARING THIS SEAL AND WET SIGNATURE ARE AUTHENTICATED. RESPONSIBILITY FOR ALL OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS ARE DISCLAIMED.

REVISIONS 2018-12-20

ISSUED FOR PLAN CHECK

2018-12-20

ISSUED FOR HEALTH DEPT. PLAN CHECK

DATE 2018.11.28 PROJECT NUMBER A2049

N

DEMOLITION FLOOR PLAN

SCALE 1/8" = 1'-0"

C COPYRIGHT 2018 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.

1

SHEET NUMBER

AD1.1


9

8

7

6

40'-2"

5

4

3

15'-1"

TODDLER ZONE

2

107

SEATING AREA

108

109

A6.2

1

KEY NOTES

60'-10 1/2"

DANCE ROOM

1 (E) CPE METER

2

1

1 TYP.

TYP.

107

107A

108

109

6 TYP.

A

20'-1"

17'-3"

A 5 A6.2

D

6

1 A6.3

TYP.

B

INSTALL ACCESSIBLE SIGNAGE AT ENTRY

2

INSTALL TACTILE EGRESS SIGNAGE

3

MODIFY EXISTING BUILDING STOREFRONT AND INSTALL NEW TEMPERED GLAZING TO MATCH EXISTING AS REQUIRED.

4

MODIFY EXISTING BUILDING STOREFRONT FOR NEW DBL. DOORS ENTRY TO MATCH EXISTING AS REQUIRED.

5

PROVIDE 3/4" BULLNOSE VINYL CORNER BEAD AT PARTITION. SEE FLOOR PLAN FOR LOCATIONS.

6

LINE OF NEW GYP. BRD. WALL FURRING ABOVE

7

NEW FIRE EXTINGUISHER, UL RATING 2A-10B:C - 48" A.F.F., LOCATIONS ARE SUBJECT TO FIRE MARSHAL APPROVAL

RANCHO CUCAMONGA, CA 91730

8

(E) STEEL COLUMN

www.AmorArch.com

9

TELEPHONE PLYWOOD BACKBOARD (FIRE RATED), PAINTED WHITE - FINAL LOCATION TO BE DETERMINED BY TENANT.

LOS ANGELES | LAS VEGAS | ATLANTA

10

(E) ELECTRICAL SUB-PANEL - SEE ELECTRICAL DRAWINGS

11

(E) SERVICE SINK TO REMAIN- UNDER SEPARATE PERMIT

12

(E) ACCESS LADDER TO WATER HEATER PLATFORM TO REMAIN

13

(E) ELECTRIC 50 GAL. WATER HEATER ON PLYWOOD PLATFORM TO REMAIN

F.E.

2

5 A6.2

1 A6.2

6 TYP.

6

8 A6.2

TY P

.

C

5

5

(E) TOILET ROOMS TO REMAIN. (UNDER A SEPARATE PERMIT)

15'-8"

5'-11 1/2"

4'-0"

2

TYP.

5'-11 1/2"

TYP.

CLR.

3

EXIST. MEN'S TOILET ROOM

2 T1.3

1

4 T1.3

9483 HAVEN AVE, SUITE 100 P. 909.259.9971 | F. 909.944.8409

OWNER

TYP.

106

5 A6.2

5 TYP. VESTIBULE HI-LOW D.F.

9700 WESTCHASE, LLC, A DELAWARE LIMITED LIABILITY COMPANY TENANT INTERIOR WORK

104

B

8

EXIST. WOMEN'S TOILET ROOM

TYP.

F.E.

105

13

6'-2"

+34"

5

12'-0"

2 TYP.

+34" CASHIER COUNTER

7 A6.2 F.E.

4 112

1'-6"

8'-6 1/2"

102

SEE REFLECTED CEILING PLAN FOR SOFFIT AND LIGHTING INFORMATION.

3.

NOTIFY ARCHITECT IMMEDIATELY OF ANY INCONSISTENCIES OR DISCREPANCIES WITH PLANS IN RELATION TO EXISTING FIELD CONDITIONS.

4.

WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE ON THE CONSTRUCTION DOCUMENTS. DO NOT EVER SCALE DRAWINGS.

5.

DIMENSIONS ARE FROM THE FACE OF FINISHED WALL (GWB) TO FACE OF FINISHED WALL (GWB), UNLESS OTHERWISE NOTED ON PLANS.

6.

ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE APPLIED, INSTALLED, CONNECTED, ERECTED, CLEANED AND CONDITIONED IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN SPECIFICATIONS AND/OR INSTRUCTIONS.

2

TYP.

7.

ALL WORK SHALL BE EXECUTED IN A MANNER ACCEPTABLE TO THE ARCHITECT, OWNER, AND LANDLORD UNLESS NOTED OTHERWISE. THE GENERAL CONTRACTOR SHALL PROVIDE AND PAY ALL LABOR, MATERIALS EQUIPMENTS, TOOLS, CONSTRUCTION EQUIPMENT, MACHINERY, TRANSPORTATION AND OTHER SERVICES AND FACILITIES NECESSARY FOR PROPER AND TIMELY EXECUTION OF WORK.

111

8.

THE CONTRACTOR WARRANT TO THE OWNER AND TO THE ARCHITECT THAT ALL MATERIALS AND EQUIPMENT FURNISHED UNDER THE CONTRACT ARE NEW UNLESS OTHERWISE SPECIFIED, AND THAT ALL WORKS SHALL BE AS SPECIFIED AND FREE OF DEFECTS.

9.

ALL OUTSIDE CORNERS AT DRYWALL PARTITION AND FURRING TO HAVE METAL CORNER BEADS SPACKLE AND SMOOTH.

6 TYP. F.E.

101 LOBBY ENTRANCE

1

101

4

C

1

SEATING AREA

TYP.

111

D

3

1

4

10. PROVIDE DIAGONAL BRACING TO STRUCTURE ABOVE ALL NEW DOORS, GLAZING HEADS AND JAMBS AS REQUIRED TO MAKE ASSEMBLY RIGID.

TYP.

11. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE FINAL CLEAN UP OF THE AREA OF WORK AND AREA AFFECTED BY CONSTRUCTION; TO INCLUDE BUT NOT LIMITED TO FLOORS, MILLWORK, FIXTURES, ETC. FOLLOWING THE INSTALLATION OF THE MILLWORK. 12. THE GENERAL CONTRACTOR SHALL COORDINATE THE LOCATIONS FOR THE WALL MOUNTED TELEVISIONS AND GRAPHIC SIGNAGE TO PROVIDE BLOCKING FOR MOUNTING. 13. ALL WET/PLUMBING WALLS ARE TO BE PROVIDED WITH MOISTURE RESISTANT GYPSUM BOARD. UNLESS TILE IS TO BE USED, THEN PROVIDE CEMENT BACKER BOARD. 14. ALL PLUMBING WALLS ARE TO BE 6" METAL STUD FRAMING. PROVIDE REQUIRED BLOCKING FOR WALL MOUNTED FIXTURES, GRAB BARS, SHELVING, CABINETRY, ETC. 15. THERE SHALL BE NO PENETRATIONS TO A DEMISING WALL. UNLESS OTHERWISE NOTED. IF PENETRATIONS ARE TO BE NOTED, THEN ALL PENETRATIONS INCLUDING CONDUITS, PIPES, DUCTWORK, ETC. SHALL BE UL RATED PER CURRENT CODE REQUIREMENTS. 16. NO PLUMBING IS ALLOWED IN DEMISING WALLS. FURR OUT AS REQUIRED. 17. ALL (E) DEMISING WALLS FOR TENANT SEPARATION ARE NOT TO BE DISTURBED OR MODIFIED IN ANY WAY.

1

WALL TYPES REFER TO SHEET A7.1 FOR PARTITION TYPES

18 "M IN.

1 EXISTING MASONRY EXTERIOR WALL WITH FULL-HEIGHT GYP. BRD. FURRING TO REMAIN

WIL L

AT

5 A7.1

IA

A

CT ITE

1/8" = 1'-0"

ST

NEW CONSTRUCTION FLOOR PLAN

RED ARCH E T M A. R MO

SCALE

18. PROVIDE PORTABLE FIRE EXTINGUISHER(S) IN ACCORDANCE WITH NFPA 10, WITH U.L. LABEL AND A RATING OF NOT LESS THAN 2-A WITH 75 FEET OR TRAVEL DISTANCE TO ALL POSITIONS OF STORE AND/OR AS DIRECTED BY THE FIRE DEPARTMENT FIELD INSPECTOR.

STAMP

REG IS

N

NEW CONSTRUCTION FLOOR PLAN AND GENERAL NOTES

103

7'-11 1/2"

TYP. +34"

2.

+34"

3

SEE SHEET K1.1 FOR EQUIPMENT, FURNITURE, FIXTURES AND PLUMBING FIXTURES.

SHEET TITLE

6'-6"

+34"

C

1.

16 5 9 9

AS

5 TYP.

B

CONSULTANT

15135 NORTH FREEWAY, HOUSTON, TEXAS 77042

102

6 A6.2

MIN.

2 A6.3

D

BAR AREA

GENERAL NOTES

TENANT IMPROVEMENT GARDEN CENTER SUITE #800

5 5" TYP. CLR.

TYP. TYP.

+36" DISPLAY CASE

21'-4"

A

6'-3"

5 TYP.

TYP.

5

3

KIDS EMPIRE USA, LLC

3

103

110

27'-11"

10

CLR.

11

+34"

PANTRY AREA

2'-9" 3'-6" 2'-9"

9

34" CASHIER COUNTER

12

34" CASHIER COUNTER

W/H

PLAY EQUIPMENT AREA

SEATING AREA 112

PROJECT LOCATION

PLYWOOD PLATFORM ABOVE

E OF T EX

SHEETS BEARING THIS SEAL AND WET SIGNATURE ARE AUTHENTICATED. RESPONSIBILITY FOR ALL OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS ARE DISCLAIMED.

Plotted: 12/20/2018 1:15 PM (jlavenant) File: 07_a2049_a1.1_floor plan.dwg

REVISIONS 2 EXISTING 6" x 20GA. METAL STUDS @ 16" O.C. w/ 5/8" TYPE "X" GYP. BD. ON EACH SIDE FULL HEIGHT DEMISING WALL PARTITION TO REMAIN 6"

3

MA

N.

43"

MI

27" MIN.

8"

36" MAX

X.

4

5

6

ISOMETRIC AT DRINKING FOUNTAIN C COPYRIGHT 2018 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.

SCALE N.T.S.

2

EXISTING PARTIAL HEIGHT AT 10'-0" A.F.F. 3 - 5/8" X 20GA. METAL STUDS @ 16" O.C. w/ 5/8" TYPE "X" GYP. BD. PARTITION TO REMAIN

6 A7.1

NEW PARTIAL HEIGHT PARTITION AT 4'-0" A.F.F. 3 - 5/8" x 20GA. METAL STUDS @ 16" O.C. w/ 5/8" TYPE "X" GYP. BD. ON EACH SIDE

7 A7.1

2018-12-20

ISSUED FOR PLAN CHECK

2018-12-20

ISSUED FOR HEALTH DEPT. PLAN CHECK

DATE 2018.11.28 NEW PARTIAL HEIGHT PARTITION AT 13'-0" A.F.F. 3 - 5/8" x 20GA. METAL STUDS @ 16" O.C. w/ 5/8" TYPE "X" GYP. BD. ON EACH SIDE

8 A7.1

PROJECT NUMBER A2049

SHEET NUMBER NEW PARTIAL HEIGHT PARTITION AT 13'-0" A.F.F. 3 - 5/8" x 20GA. METAL STUDS @ 16" O.C. w/ 5/8" TYPE "X" GYP. BD. ON EACH SIDE

ALIGN

9 A7.1

A1.1


(E )E P (E )E P

(E )E P

(E )E P

(E )E P

PT-2

PT-2 PT-3

PT-2 PT-3

SV-1

PT-5

PT-1

PT-2

101 102 103 104 105 106 107 108 109 110 111 112

CP-2

PT-5

PT-1

PT-2

SV-1

GB-1

VB-1

VB-1

PT-4

NOTES

LOBBY ENTRANCE BAR AREA PANTRY AREA VESTIBULE AREA WOMEN'S TOIL. RM. MEN'S TOIL. ROOM TODDLER AREA DANCE ROOM OPEN SEAT'G AREA PLAY EQUIP. AREA OPEN SEAT'G AREA OPEN SEAT'G AREA

HEIGHT

2

PT-3

GB-1

CT-1

SS-2

A

CEILING

1 T-1

(E) CPE METER

WALL

FRP

109

BASE

PT-2

108

FLOOR

PT-1

107

ROOM NAME

SS-1

OPEN SEATING AREA

ROOM FINISH SCHEDULE

1

QTB-1

DANCE ROOM

2

VB-1

TODDLER ZONE

3

QT-1

4

CP-2

5

CP-1

6

SV-1

7

CF-1

8

ROOM NO.

9

OPEN OPEN 11'-0" 9'-0" 9'-0" 9'-0" OPEN 12'-0" OPEN OPEN OPEN OPEN

1 2 1 1 1 1 1 1 1

2 2 2 2 2 2 2

9483 HAVEN AVE, SUITE 100 RANCHO CUCAMONGA, CA 91730

1 2 1 2

P. 909.259.9971 | F. 909.944.8409 www.AmorArch.com LOS ANGELES | LAS VEGAS | ATLANTA

PT-5

OWNER

EXIST. MEN'S TOILET ROOM

1

PT-4

A6.2

106

T-1 PT-2

GB-1

FINISH SCHEDULE: FINISH PLAN

EXIST. VESTIBULE 104

PLAY EQUIPMENT AREA

OPEN SEATING AREA 112

110

1

34" CASHIER COUNTER

PT-3

PANTRY AREA +34"

103

PT-1 PT-4

102

QTB-1

PT-1

PT-3

PAINT COLOR: DUNN EDWARDS, WHITE DRY FALL, COLOR: DEW 380 FLAT

CP-2

VB-1

VB-1

PT-1

PAINT COLOR: YELLOW, SPEC. TO BE SELECTED BY OWNER

PT-2

PAINT COLOR: DUN EDWARDS SILVER BULLET #6381

PT-4

PAINT COLOR: LIGHT PINK, SPEC. TO BE SELECTED BY OWNER

PT-5

PAINT COLOR: DARK PINK, SPEC. TO BE SELECTED BY OWNER

QTB-1

FRP

FIBER REINFORCED PLASTIC- MARLITE STD. FRP, SMOOTH SURFACE: COLOR S100G-WHITE. INSTALL WITH PVC TRIM-WHITE

T-1

ARIZONA TILE, RESIDE SERIES RECTIFIED COLOR BODY PORCELIAN DIGITAL PRINT TECHNOLOGY SEMI-POLISHED COLOR. SIZE:12"X24"

SS-2

CUSTOM BUILDING PRODUCTS, STAINLESS STEEL SATIN EDGE- PROTECTION PROFILE

VB-1

3/8" COVE RADIUS VINYL BASE TO BE SELECTED BY OWNER

+34"

PT-1 QT-1

+36" DISPLAY CASE

+34"

+34"

QT-1

SV-1

WALL

QT-1

1/2" W.R. GYPSUM BOARD OVER METAL STUD FRAMING @ 16" O.C. PAINT CEILING WITH SEMI-GLOSS ENAMEL

PT-1

TYP.

34" CASHIER COUNTER

BAR AREA

PT-3

(E) TOILET ROOMS TO REMAIN. (UNDER A SEPARATE PERMIT)

PT-5 FRP-1

A6.2

GB-1

+34"

PT-5

CONSULTANT

PT-1

QTB-1

PT-2

CP-1 VB-1 PT-2 OPEN SEATING AREA

101

111

QUARRY TILE- COVE BASE. COLOR TO BE SELECTED BY TENANT.

SS-1

CUSTOM BUILDING PRODUCTS, PROCOVE "E" COVE SHAPED PROFILE, STAINLESS STEEL SATIN COVE (8 FT. X 2 1/2")

CF-1

CONCRETE FLOOR

SV-1

SHEET VINYL FLOOR- >+> FLOORING GROUP CLASSIC COLOR: ESTABLISHED 1002, 9"X48" PLANK. (V500) INSTALLATION METHOD: ASHLAR (9X48)

CP-1

ARTIFICIAL GRASS (FLAME RETARDANT), STANDARD ROLLS BY ARIZON GRASS X-TINGUISH #7040 DEEP GREEN.

CP-2

BRAODLOOM CARPET- ALADDIN COMMERCIAL TOWN CENTER II, STYLE # 1E73, 30 OZ. COLOR: T.B.D.

QT-1

QUARRY TILE- 6"X6" COLOR TO BE SELECTED BY TENANT.

C D

FLOOR

ENTRANCE LOBBY

QTB-1

T-1

ARIZONA TILE, RESIDE SERIES RECTIFIED COLOR BODY PORCELIAN DIGITAL TECHNOLOGY, SIZE 12"X24". COLOR GROUT MATTE FINISH

FLOORING NOTES

TENANT IMPROVEMENT GARDEN CENTER SUITE #800

PT-2

STAMP

2.

ANY DIFFERENCES WITH JOB SITE CONDITIONS CONTACT ARCHITECT BEFORE PROCEEDING.

3.

SEE INTERIOR SHEET A8.1 FOR WALL FINISHES

4.

SEE REFLECTED CEILING PLAN FOR CEILING TYPES AND HEIGHTS

RED ARCH E T M A.

ST

Plotted: 12/20/2018 1:54 PM (jlavenant) File: 08_a2049_a1.2_floor finish plan.dwg

AT

ROOM FINISH NOTES

IA

A

CT ITE

PROVIDE FLUSH JOINTS AT TRANSITIONS.

R MO

1.

W IL L

PT-2

REGI S

PT-2

BASE

PT-1

PT-1

PROJECT LOCATION

PT-2

KIDS EMPIRE USA, LLC

+34" CASHIER COUNTER

ROOM / FLOOR FINISH PLAN & ROOM FINISH SCHEDULE & NOTES

GB-1

SUSPENDED T-BAR CEILING PANELS, TILE: ARMSTRONG CLEAN ROOM VL UNPERFORATED #870 WHITE LAY-IN

SHEET TITLE

105

CT-1

16 5 9 9

AS

T-1

9700 WESTCHASE, LLC, A DELAWARE LIMITED LIABILITY COMPANY TENANT INTERIOR WORK

15135 NORTH FREEWAY, HOUSTON, TEXAS 77042

EXIST. WOMEN'S TOILET ROOM

CEILING

B

E OF T EX

SHEETS BEARING THIS SEAL AND WET SIGNATURE ARE AUTHENTICATED. RESPONSIBILITY FOR ALL OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS ARE DISCLAIMED.

REVISIONS

1

SEE INTERIOR ELEVATIONS FOR WALL FINISHES

2

SEE REFLECTED CEILING PLAN FOR CEILING TYPES AND HEIGHTS

2018-12-20

ISSUED FOR PLAN CHECK

2018-12-20

ISSUED FOR HEALTH DEPT. PLAN CHECK

FLOOR LEGEND WALK - OFF ENTRY CARPET TILE BOLYU COMMERCIAL CARPET TILE ACCESS: PATTERN/COLOR: PROCURE AX302 TILE WIDTH: 24" x 24"

N

ROOM / FLOOR FINISH PLAN C COPYRIGHT 2018 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.

SCALE 1/8" = 1'-0"

DECORATIVE RESILIENT TILE: PARTERRE FLOORING SYSTEM: DECO NOUVEAU 78820 CARPET TILES BOLYU COMMERCIAL: PATTERN/COLOR: LOW TIDE LWT33

1

DATE 2018.11.28 PROJECT NUMBER A2049

SHEET NUMBER

A1.2


9

8

7

6

5

4

TODDLER ZONE

DANCE ROOM

OPEN SEATING AREA

107

108

109

3

2

1

CEILING VARIES

(E) CPE METER

6" 1

2

2

THERMOSTAT

+ A . 28 F. " F.

EXIST. MEN'S TOILET ROOM

9483 HAVEN AVE, SUITE 100 RANCHO CUCAMONGA, CA 91730 P. 909.259.9971 | F. 909.944.8409 www.AmorArch.com LOS ANGELES | LAS VEGAS | ATLANTA

OWNER

EQ-14

TELE. & ELEC.

106

TYPICAL BOTTOM OF OUTLET MOUNTING HEIGHT U.O.N. ON PLANS

(E) TOILET ROOMS TO REMAIN. (UNDER A SEPARATE PERMIT) EXIST. VESTIBULE + A. 15 F. " F.

2 3/4" VERIFY W/ HDWR SCHED. 6" 15"

+2 8

"

EQ-15 F.

F.

A.

EQ-14

42"

SP

+ A. 28 F. " F.

SP

BLDG. STD. OR 3'-2" VERIFY"

+ A. 80 F. " F.

+ A. 80 F. " F.

LIGHT CONTROL SWITCH

SEE DOOR TYPES/SCHEDULE

+ A. 28 F. " F.

(E )E P (E )E P

(E )E P

+ A. 28 F. " F.

+ A. 28 F. " F.

P (E )E

P (E )E

HINGE, TYP.

DOOR FRAME

A

104

B

EXIST. WOMEN'S TOILET ROOM

MOUNTING HEIGHT NOTES AND ELEVATION

SCALE 1/4" = 1'-0"

2

9700 WESTCHASE, LLC, A DELAWARE LIMITED LIABILITY COMPANY TENANT INTERIOR WORK

105

+ A. 28 F. " F.

+ A. 44 F. " F.

+34"

5

NEW ELECTRICAL WIREMOLD MTD. ON EXISTING MULLION +30" A.F.F. FOR I-PAD CHECK-IN STATIONS AT LOBBY ENTRANCE #101. VERIFY WITH TENANT FOR EXACT LOCATION AS REQUIRED.

6

NEW TELEPHONE BACK BOARD, FIRE RATED PLYWOOD, PAINTED WHITE. VERIFY WITH TENANT FOR EXACT LOCATION AS REQUIRED.

RU

EQ-1

+ A. 28 F. " F.

5

EQ-1

+ A 28 V. .F.F " I.F . .

+ A 28 V. .F.F " I.F . .

+ A. 28 F. " F.

EQ-1

+ A 28 V. .F.F " I.F . .

4

ENTRANCE LOBBY

OPEN SEATING AREA

101

111

C D

N SCALE

POWER & SIGNAL PLAN

1/8" = 1'-0"

REF

QT

EQ-1

3

FIX #

SEE FIXTURES SHEET FOR TYPES AND DETAILS

LEGEND

GENERAL NOTES

DESCRIPTION I-PAD ON PEDESTAL STAND SIGN IN STATION 1.

BOTTOM OF NEW OUTLETS TO BE MOUNTED AT +15" A.F.F. UNLESS NOTED OTHERWISE.

2.

ALL ELECTRICAL OUTLETS & SWITCHES WITHIN 6'-0" OF SINK TO BE PROTECTED BY GROUND FAULT INTERRUPT CIRCUIT PER CBC SECTION 210-8(b).

ICE CREAM CHEST (24"W X 35"H X 26"D)

EQ-3

1

GLASS DOOR MERCHANDISER: SWING DOOR REFRIG. (30"W X 30"D X 79"H)

EQ-4

1

GLASS DOOR MERCHANDISER: SWING DOOR REFRIG. (30"W X 30"D X 79"H)

EQ-5

2

TABLE

3.

PROVIDE PULL STRINGS TO PLENUM AT ALL TELE/DATA OUTLET LOCATIONS.

EQ-6

2

COMMERCIAL MICROWAVE OVEN

4.

EQ-7

2

60"W METAL SHELVING RACK

REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL ELECTRICAL DATA INFORMATION.

EQ-8

3

72"W METAL TABLE

EQ-9

1

LG WASHER AND DRYER (27"W X 38 11/16"D X 29 3/4"H), (51"H WITH DOOR OPEN)

EQ-10

1

REFRIGERATOR AND FREEZER (29"W X 82.5"H X 33"D)

EQ-11

1

REFRIGERATOR AND FREEZER (29"W X 82.5"H X 33"D)

EQ-12

1

EMPLOYEE METAL LOCKER, 6 TIER (12"W X 12"D X 66"H)

EQ-13

1

TOKEN MACHINE

EQ-14

2

GRAB FUN ZONE MACHINE

EQ-15

1

BABY AIR TABLE

5.

- ALL OUTLETS TO BE MOUNTED AT CENTERLINE OF PARTITION FACE, U.O.N.

6.

GENERAL CONTRACTOR TO VERIFY SHOWROOM POWER: AT ALL LOCATIONS OF RECEPTACLES FOR FIXTURES, INTERIOR / EXTERIOR SIGNS, AND EQUIPMENT WITH CELLULAR SALE PRIOR TO ROUGH IN. - POWER OUTLETS

+15" BOTTOM OF OUTLET, U.N.O.

- TELEPHONE/DATA OUTLETS

+15" BOTTOM OF OUTLET, U.N.O.

- LIGHT SWITCHES

+42" A.F.F.

- FIRE ALARM

+42" A.F.F.

- THERMOSTATS

+42" A.F.F.

WALL MOUNTED DOUBLE DUPLEX ELECTRICAL OUTLET WALL MOUNTED DEDICATED DUPLEX ELECTRICAL OUTLET

STAMP

WALL MOUNTED DEDICATED DOUBLE DUPLEX ELECTRICAL OUTLET WALL MOUNTED DUPLEX ELECTRICAL OUTLET SEPARATE CIRCUIT 120V WALL MOUNTED DOUBLE DUPLEX ELECTRICAL OUTLET SEPARATE CIRCUIT 120V WALL MOUNTED TELEPHONE OUTLET W/ 1" DIAMETER CONDUIT. PROVIDE MUDRING AND PULL-STRING TO HEAD OF WALL WALL MOUNTED COMBINATION TELEPHONE/DATA OUTLET

WALL MOUNTED DATA OUTLET

(REFER TO MOUNTING HEIGHT NOTES & ELEVATION DETAIL #4 ON THIS SHEET)

FLOOR MOUNTED ELECTRICAL/DATA BOX. SEE REFERENCED NOTE & DETAIL

NOTE:

INDICATES ELECTRICAL WIREMOLD

INSTALL LOCAL ELECTRICAL AND TELEPHONE WALL OUTLETS AND SWITCH PLATES AT NEAREST STUD FROM SCALED LOCATION ON PLAN UNLESS SPECIFICALLY DIMENSIONED.

DR

UNDER COUNTER DOOR RELEASE BUTTON. VERIFY WITH TENANT FOR EXACT LOCATION AND REQUIREMENTS.

RU

BUZZER - REMOTE UNLOCK WITH ELECTRONIC LOCK. VERIFY WITH TENANT FOR EXACT LOCATION AND REQUIREMENTS.

RED ARCH E T M A.

AT

IA

A

CT ITE

1

R MO

EQ-2

WALL MOUNTED DUPLEX ELECTRICAL OUTLET

ST

Plotted: 12/20/2018 1:19 PM (jlavenant) File: 09_a2049_a1.3_power & signal plan.dwg

EQUIPMENT LIST

1

POWER & SIGNAL PLAN AND EQUIPMENT LIST

10

SHEET TITLE

+34" CASHIER COUNTER DR

9

16 5 9 9

AS

F.

F.

A.

NEW MILLWORK CABINET AND DISPLAY CASE BY OTHER.

8

+36" DISPLAY CASE

+8 0" A.

"

" A.

F.

.

F F.

+34" F.

+4 4

A.

F.

F.

+4 4

+4 4

"

+34"

4

7

EQ-2

SP

NEW 400 AMP ELECTRICAL PANEL (SURFACE MOUNTED) WIRED TO A 42 BREAKER SUB-PANEL BY LANDLORD.

15135 NORTH FREEWAY, HOUSTON, TEXAS 77042

+ A. 44 F. " F. + A. 44 F. " F.

EQ-7 EQ-7

3

CONSULTANT

TENANT IMPROVEMENT GARDEN CENTER SUITE #800

+34"

103

EXISTING RECESSED ELECTRICAL PANELS TO REMAIN FOR POSSIBLE RE-USE.

+ A. 44 F. " F.

EQ-12

2

WIL L

EQ-5

EQ-11

4 TYP.

EXISTING RECESSED ELECTRICAL PANELS TO BE ABANDON.

KIDS EMPIRE USA, LLC

EQ-4

+ A. 28 F. " F.

+ A. 28 F. " F.

102 EQ-10

1

REG IS

BAR AREA

EQ-3

. .F EQ-9

F A.

+ A. 28 F. " F.

110

+ A. 28 F. " F.

EQ-5

34" CASHIER COUNTER

+2 8

"

+ A. 28 F. " F.

EQ-8

OPEN SEATING AREA 112

PROJECT LOCATION

+34"

P 3

34" CASHIER COUNTER

" F F. A. EQ-7

EQ-8

)E

.

+4 4

+ A. 44 F. " F.

EQ-6

+ A. 44 F. " F.

SP EQ-6

(N

+ A. 80 F. " F.

PLAY EQUIPMENT AREA

6

PANTRY AREA

KEYNOTES

F-13

+ A 15 V. .F.F " I.F . .

W/H

+ A. 28 F. " F.

PLYWOOD PLATFORM ABOVE

E OF T EX

SHEETS BEARING THIS SEAL AND WET SIGNATURE ARE AUTHENTICATED. RESPONSIBILITY FOR ALL OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS ARE DISCLAIMED.

REVISIONS 2018-12-20

ISSUED FOR PLAN CHECK

2018-12-20

ISSUED FOR HEALTH DEPT. PLAN CHECK

INDICATES FIRE RATED PLYWOOD BACKBOARD.

) (E ) (D ) (R ) (N

DENOTES EXISTING DEVICE TO REMAIN DENOTES EXISTING DEVICE TO BE DEMO'D DENOTES RELOCATED DEVICE DENOTES NEW DEVICE

DATE 2018.11.28 PROJECT NUMBER A2049

SHEET NUMBER

A1.3 C COPYRIGHT 2018 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.


8

7

6

TODDLER ZONE

5

4

DANCE ROOM

107

2

1

108

SPREADER

109 EXPOSED STRUCTURE NO CEILING OR GRID +22'-6" BOTTOM OF ROOF

(E )

KEY NOTES

WALL (SEE FLOOR PLAN FOR TYPE)

SEATING AREA

GYP. BOARD. +12'-0" (N) CLG. HT.

EXPOSED STRUCTURE NO CEILING OR GRID +22'-6" BOTTOM OF ROOF

3

HEAVY DUTY T-BAR SYSTEM

16

(E )

9

A

1

NEW GYP. BRD. CEILING +12'-0" A.F.F

2

NEW GYP. BRD. CEILING +9'-0" A.F.F.

3

NEW +13'-0" A.F.F. OUTER GYP. BRD. PARAPET

4

NEW EXHAUST FAN - SEE MECHANICAL DRAWINGS

5

HVAC SUPPLY AIR DIFFUSER - SEE MECHANICAL DRAWINGS

6

HVAC RETURN AIR DIFFUSER - SEE MECHANICAL DRAWINGS

7

NEW 6" DIA. RECESSED LED DOWNLIGHT W/ WHITE TRIM

8

6"X6" STRUCTURAL COLUMN

9

(E) +20'-6" A.F.F. BOTTOM OF OPEN WEB STEEL JOIST. GENERAL CONTRACTOR TO PAINT THRU-OUT, COLOR: WHITE

P )E

3/4" MIN.

(E

(E

)E

P )E E.Q.

(E

E.Q.

E.Q.

10

3

3

2" MIN.

TYP.

FASTENED TO WALL

7 1 12

E.Q.

3

NOTE: 1. PROVIDE SPREADER BAR IF CROSS TEE OR MAIN TEE DISTANCE TO WALL IS GREATER THAN 8''.

TYP. E.Q.

2'-6"

E.Q.

5

2

4'-2"

7

TYP. E.Q.

106

OS

2

3'-4"

7

EXIST. VESTIBULE

E.Q.

GYP. BOARD. +9'-0" CLG. HT.

E.Q.

B 8

8

TYP.

E.Q.

3'-4"

E.Q.

TWO ADJACENT CEILING GRID EDGES MUST BE ATTACHED TO THE PERIMETER ANGLE, AND THE OTHER TWO EDGES MUST BE FREE TO SLIDE AND HAVE 3/4'' MINIMUM CLEARANCE FROM WALL.

12

104

7

7

2.

(E) TOILET ROOMS TO REMAIN. (UNDER A SEPARATE PERMIT)

E.Q. E.Q.

E.Q. 4

E.Q.

GYP. BOARD. +9'-0" CLG. HT.

SCALE

CEILING PERIMETER

3" = 1'-0"

TYP.

2

4 4'-2"

105

2

7 2'-6"

E.Q.

5 E.Q.

E.Q.

14

PLAY EQUIPMENT AREA

18

E.Q.

2'-6"

THE SUSPENDED CEILINGS IN SEISMIC DESIGN CATEGORIES D, E & F COMPLY WITH ASCE 7-10 SECTION 13.5.6.2.2 AS FOLLOWS: a) ALL CEILINGS SHALL USE A HEAVY DUTY T-BAR GRID SYSTEM. b) THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE NOT LESS THAN 2 INCHES. c) THE OTHER END IN EACH HORIZONTAL DIRECTION SHALL A 3/4" CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO SLIDE ON A CLOSURE ANGLE OR A LISTED ASSEMBLY. d) CEILING AREAS OVER 1,000 FT. MUST HAVE HORIZONTAL RESTRAINT WIRES (TYPICALLY RESTRAINT WOULD CONSIST OF FOUR 12 GAUGE WIRES SPLAYED 90째 TO EACH OTHER AND SLOPED 45째 TO THE HORIZONTAL, SPACED 12" O.C.) e) CEILING AREAS OVER 2,500 FT. MUST HAVE SEISMIC SEPARATION JOINTS OR FULL HEIGHT PARTITIONS. f) CEILINGS WITHOUT RIGID BRACING MUST HAVE 2" OVERSIZE TRIM RINGS FOR SPRINKLERS AND OTHER CEILING PENETRATIONS. g) IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF THE CEILING GRID SHALL BE ATTACHED TO THE CLOSURE ANGLE.

E.Q.

OS

2'-6"

TYP.

SEATING AREA 112

E.Q.

EXIST. WOMEN'S TOILET ROOM GYP. BOARD. +9'-0" (N) CLG. HT.

17

7

110 EXPOSED STRUCTURE NO CEILING OR GRID +22'-6" BOTTOM OF ROOF

EXPOSED STRUCTURE NO CEILING OR GRID +22'-6" BOTTOM OF ROOF

3

TYP.

5

EQ.

CL OF FULL TILE

15

9

TYP.

EQ.

13

PANTRY AREA

3

OS

TYP.

103 ACT-1 +12'-0" (N) CLG. HT. 4'-0"

15

102

6 2'-0"

12

EQ.

EQ. 3

TYP.

TYP.

CL OF FULL TILE

12

TYP. TYP. TYP. 19

(N) CEILING GRID, ACT-1: USG WHITE ACOUSTICAL CEILING 13 TILE, 24"X48" SMOOTH WASHABLE @ PANTRY AREA. ACOUSTICAL CEILING SUSPENSION ASSEMBLY: ESR-1222 14 OPEN FOR ACCESS FOR W/H 15

2' X 4' STANDARD L.E.D. LIGHT FIXTURE (RECESSED) WITH PRISMATIC LENSE (SEE LEGEND)

16

(E) SECURITY ACCESS BUILDING ROOF LADDER

17

LINE OF NEW TODDLER ZONE AREA

18

LINE OF NEW EQUIPMENT AREA

19

LINE OF NEW FURRED GYP. BRD. SOFFIT ABOVE

TYP.

45째 TYP.

19

GENERAL NOTES

)

C (E

)

(E

SEATING AREA 111

D

#6 STSM SCREW

1.

EMERGENCY LIGHTS TO BE INSTALLED ON SEPARATE CIRCUIT.

2.

ALL FIXTURES TO BE INSTALLED IN ACOUSTIC CEILING AREA AND SHALL BE LOCATED AT THE CENTER OF 2'-0" x 2'-0" CEILING GRID UNLESS NOTED OTHERWISE.

3.

ALL FINISHING AND PAINTING REQUIREMENTS SHALL BE DIRECTED TO THE FINISH SCHEDULE SPECIFICATIONS & INTERIOR ELEVATIONS.

4.

ALL LIGHT FIXTURES INCLUDING EXIT LIGHTS, EMERGENCY LIGHTS, ETC., SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR.

5.

CONTRACTOR TO USE LASER FOR LEVELING OF ALL SOFFITS, CEILINGS AND SUSPENDED GRIDS.

6.

ELECTRICAL CONTRACTOR TO VERIFY IF SERVICE PROVIDED IS ADEQUATE. NOTIFY ARCHITECT IMMEDIATELY IF NOT.

7.

ALL EQUIPMENT SHALL BEAR U.L. LABELS.

8.

GENERAL CONTRACTOR SHALL FOLLOW AND COMPLY WITH CURRENT STATE AND LOCAL ENERGY CODE REQUIREMENTS.

9.

ALL LIGHTING CIRCUITS SHALL BE CONTROLLED BY AN EXISTING TIME CLOCK.

)

J

SIGN

(E

EXPOSED STRUCTURE NO CEILING OR GRID +22'-6" BOTTOM OF ROOF

)

11

EXPOSED STRUCTURE NO CEILING OR GRID +22'-6" BOTTOM OF ROOF

)

(E

(E

101

(E

SIGN

) (E

11

NOTE: REFER TO ELECTRICAL / MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.

N

) (E

LOBBY ENTRANCE

)

EXIT

J

REFLECTED CEILING PLAN

2''

HEAVY DUTY MAIN TEE

MAX

AX.

6'' M

SCALE 1/8" = 1'-0"

., TY

P.

CROSS TEE

1 CEILING BRACING DETAIL

SCALE 3" = 1'-0"

LEGEND

T-BAR RETURN AIR DIFFUSER 2' X 4' ACOUSTICAL SUSPENDED GRID SYSTEM - WASHABLE CORTEGA, SECOND LOOK (SCORED TEGULAR) MEDIUM TEXTURE WITH 15/16" REGULAR WHITE LOOK LIKE 2'X2'

EXHAUST FAN - 5 AIR CHANGES PER HOUR VENT TO OUTSIDE

DENOTES EXISTING DEVICE TO BE DEMO'D

)

DENOTES RELOCATED DEVICE

)

DENOTES NEW DEVICE

(N

2' X 4' STANDARD L.E.D. LIGHT FIXTURE (RECESSED) WITH PRISMATIC LENSE

8-FEET FIXTURES WITH CONTINUOUS LENS, SS LED SLIM STRIP LIGHT SERIES, DOUBLE ROWS OF LED. SURFACE MOUNTED, OR SUSPENDED MOUNTED WITH CHAINS, STEMS OR CABLES. UTOPIA LIGHTING US

Plotted: 12/20/2018 1:41 PM (jlavenant) File: 10_a2049_a2.1_new rcp.dwg

6" DIA. RECESSED LED DOWNLIGHT W/ WHITE TRIM

10. ELECTRICAL CONTRACTOR MUST PROVIDE AN IDENTIFICATION NAMEPLATE ON TENANT's MAIN ELECTRICAL SERVICES FUSIBLE DISCONNECT SWITCH IN LANDLORD's DISTRIBUTION PANEL AND R.T.U. NAMEPLATE MUST BE 1/8" THICK PLASTIC, BLACK ON WHITE ETCHED TO LEAVE WHITE LETTERS. THE SIZE SHALL BE ONE INCH HIGH BY REQUIRED LENGTH, WITH TENANT'S SPACE NUMBER ENGRAVED ON IT, AND PERMANENTLY AFFIX TO DISTRIBUTION PANEL. 11. DIFFUSERS TO HAVE HANG WIRES ON ALL FOUR CORNERS. ALL LIGHT FIXTURES TO HAVE HANG WIRES ATTACHMENT. 12. ALL FIRE DAMPERS MUST BE IDENTIFIED BY A STICKER INSTALLED ON CEILING BELOW. DUCT FIRE DAMPER MUST BE INSTALLED WITH A BREAKAWAY CONNECTION PLENUM THAT SHALL NOT CONTAIN ANY COMBUSTIBLE MATERIAL. 13. GENERAL CONTRACTOR TO INSTALL ACCESS PANEL DOORS AS NECESSARY AND CONFIRM EXACT LOCATIONS. ACCESS PANEL MUST BE FLUSH, FRAMELESS GYPSUM PANELS IN SALES AREA. G.C. MUST ALSO PROVIDE AN ALLOWANCE FOR ACCESS PANELS IN BID. 14. GENERAL CONTRACTOR TO PROVIDE AND INSTALL NEW ACOUSTIC CEILING TILES, UNLESS NOTED OTHERWISE. 15. CEILING GRID SHOULD BE IN LIKE-NEW CONDITION AND STRAIGHT.

OS

NEW OCCUPANCY LIGHT SENSOR. SEE ELECTRICAL ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION

EXIT

ILLUMINATED EXIT SIGN. SURFACE MOUNTED L.E.D. TYPE FIXTURE

16. ALL LIGHTING SHOULD BE IN WORKING ORDER AND ALL COVERS / LENSES IN PLACE.

STAMP

RED ARCH E T M A.

AT

IA

A

CT ITE

)

(R

CONSULTANT

R MO

DENOTES EXISTING DEVICE TO REMAIN

(D

9700 WESTCHASE, LLC, A DELAWARE LIMITED LIABILITY COMPANY TENANT INTERIOR WORK

ST

)

3

GYPSUM BOARD CEILING FINISH SMOOTH TEXTURE

T-BAR SUPPLY AIR DIFFUSER OR EQUAL

(E

OWNER

GENERAL CONTRACTOR TO FURNISH AND INSTALL BACKED (WHITE) R-30 INSULATION TO UNDERSIDE OF EXISTING ROOF STRUCTURE, AS REQUIRED.

#12 GA. SPLAY-WIRE LATERAL BRACING IN PLANE OF EACH RUNNER, AND TIED w/ (4) TIGHT TURNS TYP.

VERTICAL STRUT. 12' O.C., 6' MAX. FROM WALL. ATTACH TO ROOF DECK ABOVE.

9

10

LOS ANGELES | LAS VEGAS | ATLANTA

SPLAY-WIRE VERTICAL BRACING PERPENDICULAR TO RUNNER. HANGERS TO BE 12 GA. GALVANIZED, SOFT-ANNEALED MILD STEEL WIRE AT 12'-0'' O.C. AND 6'-0" MAX. FROM END WALLS. ATTACHED WITH MINIMUM OF (3) TURNS TO CEILING SUSPENSION MEMBERS AND TO 1/4'' x 3'' LAG INTO BOTTOM EDGE OF ROOF JOIST. WHERE WIRES ARE SPLAYED MORE THAN 1 IN 6 OUT OF PLUMB, PROVIDE COUNTER SLOPING WIRES. NOTE: GROUP OF (4) 45째 WIRES AND VERTICAL STRUT OCCUR AT THE SAME INTERSECTIONS.

AREA BAR

OS

www.AmorArch.com

REFLECTED CEILING PLAN AND DETAILS

EXIST. MEN'S TOILET ROOM

E.Q.

E.Q.

2'-6"

E.Q.

(N) EMERGENCY LIGHT FIXTURE w/ ILLUMINATED EXIT SIGN. 10 SEE LEGEND (N) JUNCTION BOX FOR TENANT SIGNAGE. VERIFY WITH 11 TENANT FOR EXACT POWER REQUIREMENT AND LOCATION.

P. 909.259.9971 | F. 909.944.8409

SHEET TITLE

2'-6"

RANCHO CUCAMONGA, CA 91730

16 5 9 9

AS

OS

E.Q

9483 HAVEN AVE, SUITE 100

15135 NORTH FREEWAY, HOUSTON, TEXAS 77042

E.Q.

TYP.

8" (MAX.)

6

TENANT IMPROVEMENT GARDEN CENTER SUITE #800

5

WIL L

8'-0"

1

TYP.

KIDS EMPIRE USA, LLC

7

REG IS

9

TYP.

PROJECT LOCATION

EP (E )

E.Q.

P

EXIT

E.Q.

P )E (E

E OF T EX

SHEETS BEARING THIS SEAL AND WET SIGNATURE ARE AUTHENTICATED. RESPONSIBILITY FOR ALL OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS ARE DISCLAIMED.

REVISIONS 2018-12-20

ISSUED FOR PLAN CHECK

2018-12-20

ISSUED FOR HEALTH DEPT. PLAN CHECK

17. ALL EXISTING CROWN MOLDING SHOULD BE REMOVED FROM CEILING.

EXTERIOR WALL-MOUNTED WALL SCONCE

EXTERIOR WALL PACK LIGHTING

18. CEILING ACCENT LIGHT IS INSTALLED IN 4'-0" INCREMENTS AND DROPS DOWN 1'-6" FROM THE CEILING. 19. THERE IS NO CEILING ACCENT LIGHT FIXTURE FOR CEILINGS LESS THAN 8'-0" A.F.F. 20. GENERAL CONTRACTOR TO VERIFY FIRE ALARM REQUIREMENTS AND NOTIFY ARCHITECT AS SOON AS POSSIBLE OF ANY DISCREPANCIES. 21. LIGHT FIXTURES CONTROLLED BY MULTI-LEVEL DIMMING ARE DENOTED WITH THE LETTER "D" ON THE SWITCH SYMBOL. 22. LIGHT FIXTURES ALONG WINDOWS / GLAZING SHALL BE CONTROLLED BY AN INTERIOR PHOTOSENSOR (DAYLIT AREA) AND ARE DENOTED WITH THE LETTERS "PS" ON THE SWITCH SYMBOL.

DATE 2018.11.28 PROJECT NUMBER A2049

SHEET NUMBER

A2.1 C COPYRIGHT 2018 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.


9

8

7

6

5

4

3

2

1

KEY NOTES

4

1

EXISTING HVAC, 5 TON ROOF TOP UNIT. SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION

2

EXISTING HVAC, 12 TON ROOF TOP UNIT. SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION

3

EXISTING HVAC, 15 TON ROOF TOP UNIT. SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION

4

EXISTING ACCESS EXTERIOR ROOF LADDER WITH SECURITY DOOR

(E) CPE METER

A

(E) SLOPE

(E) SLOPE

(E) SLOPE

(E) SLOPE 9483 HAVEN AVE, SUITE 100

30'-9"

27'-9"

(E) SLOPE

RANCHO CUCAMONGA, CA 91730 35'-7"

P. 909.259.9971 | F. 909.944.8409 39'-0"

www.AmorArch.com LOS ANGELES | LAS VEGAS | ATLANTA

OWNER

2

(E) #2 52'-6"

1

(E) #1

3

B

(E) #3 4'-0"

ROOF NOTES

9700 WESTCHASE, LLC, A DELAWARE LIMITED LIABILITY COMPANY TENANT INTERIOR WORK

(E) TOILET ROOMS TO REMAIN. (UNDER A SEPARATE PERMIT) 37'-6"

CONSULTANT 2

(E) #2

23'-1"

C

PROJECT LOCATION

D

EXISTING ROOF PLAN

(E) SLOPE

SHEET TITLE

(E) SLOPE

15135 NORTH FREEWAY, HOUSTON, TEXAS 77042

(E) SLOPE

TENANT IMPROVEMENT GARDEN CENTER SUITE #800

(E) SLOPE

KIDS EMPIRE USA, LLC

(E) SLOPE

A

16 5 9 9

AS

WIL L

ST

AT

IA

CT ITE

RED ARCH E T M A. R MO

REG IS

STAMP

E OF T EX

Plotted: 12/20/2018 1:43 PM (jlavenant) File: 11_a2049_a3.1_roof plan.dwg

SHEETS BEARING THIS SEAL AND WET SIGNATURE ARE AUTHENTICATED. RESPONSIBILITY FOR ALL OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS ARE DISCLAIMED.

REVISIONS 2018-12-20

ISSUED FOR PLAN CHECK

2018-12-20

ISSUED FOR HEALTH DEPT. PLAN CHECK

NOTE: REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. DATE 2018.11.28

N

PROJECT NUMBER A2049

SHEET NUMBER

EXISTING ROOF PLAN C COPYRIGHT 2018 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.

SCALE 1/8" = 1'-0"

1

A3.1


SIDE WALL OR STALL PARTITION (CENTER TOILET IN STALL IF NOT HANDICAPPED)

URINAL

12" CL

7" MIN. 9" MAX.

SIDE VIEW

INSULATE DRAIN & HOT WATER PIPES w/ WHITE ANTI SCALD PIPE WRAP.

30" 29" MIN.

33" 34"MAX.

SEAT RIM

CL

4. SURFACE OF WALL ADJACENT TO GRAB BAR IS TO BE FREE OF SHARP OR ABRASIVE ELEMENTS.

40" 39" - 41"

34" 33" - 36" 17" MIN. 19" MAX.

CL

40" 39" - 41"

44" MAX.

MAX.

17"

31" MAX. 33" MIN. 36" MAX. SANITARY NAPKIN DISPOSAL

17" MIN. 18" MAX.

FRONT VIEW

2" LONG STAINLESS STEEL VANDALRESISTANT SCREWS

FIT DRYWALL w/ "J" BEAD AND TILE TIGHT TO ANCHOR PLATE, TYP.

1 1/2" DIA. STAINLESS STEEL GRAB BAR (SEE FIXTURE SCHEDULE)

1 1/2" 1 1/2"

LAVATORY

SCALE

TYP. MOUNTING HEIGHT: RESTROOM ACCESSORIES AND FIXTURES CT-2

SCALE 3" = 1'-0"

2

34" - 44" TYP.

CT-1

M

TYP.

MIRRORS - MOUNT MIRRORS AT 39" ABOVE FINISH FLOOR TO BOTTOM OF REFLECTIVE SURFACE. (MAXIMUM 40" A.F.F.)

9.

THE RESTROOM DOORS MUST BE WELL FITTING AND SELF-CLOSING.

SS-1

C

4 -

A

4

MARK QTY

CT-1

A

CT-1

B

1'-6"

L

A

4 -

E H

2'-915 16"

D

C

SS-1

CT-1

EXIST. WOMEN'S TOILET RM. 105

CT-1

ELEVATION - D

H

LAVATORY FAUCET

LDELTA 87T110 PUSH-BUTTON FAUCET WITH MIXING VALVE

KOHLER DEXTER K5452-ET-0 URINAL WITH TOP SPUD IN WHITE

1" 11'-12

CT-1

6'-11"

BOBRICK MODEL #B-3574 (CLASSIC SERIES)

PARTITION MOUNTED SANITARY RECESSED TOILER SEAT-COVER DISPENSER, AND TOILET TISSUE DISPENSER.

BOBRICK MODEL #B-3474 CLASSIC SERIES (SATIN FINISH)

E

SURFACE MOUNTED SEAT-COVER DISPENSER

BOBRICK MODEL #B-221 CLASSICS SERIES (SATIN FINISH)

1/4" = 1'-0"

+34"

P

4

(N )E

SCALE

F

SURFACE MOUNTED SOAP DISPENSER

BOBRICK MODEL #B-2112 CLASSIC SERIES (SATIN FINISH)

G

SURFACE MOUNTED HAND DRYER DYSON AIRBLADE DB

H

3'-0" GRAB BAR

J

DOOR MOUNTED SIGNAGE

K

MIRROR

BOBRICK MODEL #B-293 1836 SERIES (SATIN FINISH)

M

TOILET PARTITIONS

SCRANTON HDPE, PLASTIC LAMINATE (COLOR: CHARCOAL GREY)

N

WALL MOUNTED WOMEN'S FEMININE TISSUE DISPENSER

1" 5'-52

(E) TOILET ROOMS TO REMAIN. (UNDER A SEPARATE PERMIT)

NOTE: SEE SHT. A1.2 & A7.5, PLAN FOR FINISH AND FIXTURE SCHEDULES

0 -

1'-0"

REFER TO THIS SHEET FOR ENLARGED FINISH PLAN AND SCHEDULE.

M TYP.

A

D

H

A

L

SS-1

ELEVATION - A

ELEVATION - B

+34" CT-1

+34"

CT-1

CT-1

FINISH LEGEND NOTE: REFER TO FINISH SCHEDULE AND FINISH LEGEND ON SHEET A8.2 FOR SPECIFICATION OF ALL INTERIOR MATERIALS AND FINISHES

WALLS

+34" CASHIER COUNTER

RED ARCH E T M A.

CT-1

CERAMIC ARIZONA TILE 1'X2' RESIDE BEIGE A8.2

CT-2

CERAMIC ARIZONA TILE 1"x6" (COLOR T.B.D.) A8.2

SS-1

SCHLUTER SYSTEMS COVE SHAPED, STAINLESS STEEL

ST-1

SOLID SURFACE SPEC: T.B.D.

AT

IA

A

16 5 9 9

E OF T EX

SHEETS BEARING THIS SEAL AND WET SIGNATURE ARE AUTHENTICATED. RESPONSIBILITY FOR ALL OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS ARE DISCLAIMED.

REVISIONS 2018-12-20

ISSUED FOR PLAN CHECK

2018-12-20

ISSUED FOR HEALTH DEPT. PLAN CHECK

DOOR OPEN POSITION

M

CT-1

ELEVATION - C

SS-1

SS-1

CT-1

PT-1

CERAMIC ARIZONA TILE 1'X2' RESIDE BEIGE A8.2

TH-1

SOLID SURFACE THRESHOLD (COLOR T.B.D.)

H

B

G

TYP.

FLOOR

F

ST-1

ELEVATION - D

(E) MEN'S TOILET ROOM INTERIOR ELEVATIONS

2'-915 16"

9' B.O. CEILING

K

2'-9"

Plotted: 12/20/2018 1:44 PM (jlavenant) File: 12_a2049_a6.1_enl restroom.dwg

M

TYP.

+36" DISPLAY CASE

L

ST-1

+34"

B TYP.

STAMP

ST

3'-113 4"

2 -

0 -

+34"

H

BOBRICK MODEL #B-5806x36" (SATIN FINISH)

CT ITE

D

CT-1

CONSULTANT

R MO

34" CASHIER COUNTER

CT-1

REMARKS

PARTITION MOUNTED SEAT COVER DISPENSER, SANITARY NAPKIN DISPOSAL, AND TOILET TISSUE DISPENSER

D

CT-1

ELEVATION - E

CT-1

ITEMS

A

SS-1

(E) WOMEN'S TOILET ROOM INTERIOR ELEVATIONS

34" - 44" TYP.

KOHLER K2196-1-0 PENNINGTON SINK

MARK QTY C

23'-6"

SS-1

9700 WESTCHASE, LLC, A DELAWARE LIMITED LIABILITY COMPANY TENANT INTERIOR WORK

WIL L

ST-1

B

C

B

CT-1

4 -

34" CASHIER COUNTER

9' B.O. CEILING

2'-9"

1" 4'-816

N

DOOR OPEN POSITION

M

D

COUNTER MOUNTED DROP-IN LAVATORY

RESTROOM ACCESSORIES

ELEVATION - C

K

KOHLER HIGHLINE K4304 BOWL & K4484 TANK

TH-1

F

CT-2

OWNER

REMARKS

FLOOR MOUNTED ELONGATED TOILET

URINAL

K

TYP.

ITEMS

INSULATE DRAIN AND HOT WATER PIPES

105

1'-6"

EXIST. MEN'S RESTROOM

LOS ANGELES | LAS VEGAS | ATLANTA

RESTROOM FIXTURES

A

TH-1

CT-1

SS-1

www.AmorArch.com

B

106

G

P. 909.259.9971 | F. 909.944.8409

18. THE INSIDE & OUTSIDE OF THE COMPARTMENT DOOR SHALL BE EQUIPPED W/ A LOOP OR U-SHAPED HANDLE IMMEDIATELY BELOW THE LATCH. THE LATCH SHALL FLIP OVER STYLE, SLIDING OR OTHER HARDWARE NOT REQUIRING THE USER TO GRASP OR TWIST.

ELEVATION - B

TYP.

RANCHO CUCAMONGA, CA 91730

17. WATER CLOSET COMPARTMENTS SHALL BE EQUIPPED WITH A DOOR THAT HAS AN AUTOMATIC CLOSING DEVICE, AND SHALL HAVE A CLEAR UNOBSTRUCTED OPENING WIDTH OF 32" WHEN LOCATED AT THE END & 34" WHEN LOCATED AT THE SIDE WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION.

SS-1

ELEVATION - A

N

9483 HAVEN AVE, SUITE 100

ENLARGED PLAN AND INTERIOR ELEVATIONS - TOILET ROOMS

ST-1

8.

SHEET TITLE

B

TYP.

OPERATING PARTS OF DISPENSING AND DISPOSAL FIXTURES (TOWELS, WASTE, COIN SLOTS, ETC.) ARE TO BE AT 40" A.F.F. MAX.

AS

A

7.

15135 NORTH FREEWAY, HOUSTON, TEXAS 77042

D

1'-0" TYP.

C

A CLEAR SPACE OF 30" X 48" SHALL BE PROVIDED IN FRONT OF LAVATORY TO ALLOW A FORWARD APPROACH TO COMPLY WITH.

C

E A

6.

16. SEE FIXTURE AND STANDARD ACCESSIBILITY MOUNTING HEIGHTS DETAIL 5 / A6.1.

DOOR OPEN POSITION

H

M

NO SHARP OR ABRASIVE SURFACES IN FRONT OF LAVATORIES.

15. REGARDLESS OF STALL CONFIGURATION, A 48" LONG MINIMUM CLEARANCE FLOOR SPACE SHALL BE PROVIDED IN FRONT OF THE WATER CLOSET.

EXIST. MEN'S TOILET RM. 106

H

5.

12. FAUCET CONTROLS AND OPERATING MECHANISM (OPERABLE W/ ONE HAND) SHALL BE OF TYPE NOT REQUIRING TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST AND AN OPERATING FORCE NOT EXCEEDING 5 LBS. 13. LAVATORIES SHALL BE MOUNTED WITH THE RIM OR COUNTER SURFACE NO HIGHER THAN 34" ABOVE THE FINISHED FLOOR & WITH A CLEARANCE OF AT LEAST 29" FROM THE FLOOR TO THE BOTTOM OF THE APRON WITH KNEE CLEARANCE UNDER THE FRONT LIP EXTENDING A MIN. OF 30" IN WIDTH & 8" MIN. DEPTH AT THE TOP. TOE CLEARANCE SHALL BE A MIN. OF 9" HIGH FROM THE FLOOR & A MIN. OF 17" DEEP FROM THE FRONT OF THE LAVATORY.

CT-1

CT-1

A

FLUSH VALVE CONTROL ON WATER CLOSET SHALL BE OPERABLE BY AN OSCILLATING HANDLE WITH MAXIMUM FORCE OF 5 LBS. TOP OF ALL ELECTRICAL SWITCHES AND CONVENIENCE OUTLET NOT TO EXCEED 40", TYPICAL THROUGH-OUT.

14. CONTROLS FOR WATER CLOSET FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF TOILET AREAS.

GRAB BAR DETAIL F

4.

11. TOILET ACCESSORIES LOCATED ON OR WITHIN WALLS BE INSTALLED AND SEALED TO PROTECT STRUCTURAL ELEMENTS FROM MOISTURE.

NOTE: SEE SHT. A1.2 & A7.5, PLAN FOR FINISH AND FIXTURE SCHEDULES

PT-1

GRAB BARS SHALL BE DESIGNED TO SUPPORT A 250# LOAD AND SHALL NOT ROTATE WITHIN THEIR FITTINGS.

TENANT IMPROVEMENT GARDEN CENTER SUITE #800

TYP. K

F

3

1/4" = 1'-0"

WALL FINISH OVER WATER RESISTANT GYPSUM BOARD

3.

KIDS EMPIRE USA, LLC

CT-1

EXIST. WOMEN'S RESTROOM

VERIFY WALL FRAMING TYPE AND PROVIDE BLOCKING AS REQUIRED. VERIFY MOUNTING HEIGHT w/ GRAB BAR MOUNTING HEIGHT

DRAIN AND HOT WATER PIPES UNDER ALL LAVATORIES TO BE INSULATED.

10. PROVIDE SUFFICIENT VENTILATION IN RESTROOMS BY MEANS OF A WINDOW OR MECHANICAL CEILING VENTILATION.

18"

WATER CLOSET & GRAB BARS

PROVIDE 1-1/2 CLEARANCE BETWEEN WALL AND GRAB BARS.

2.

REG IS

TOILET SEAT COVER DISPENSER

42"

3. BAR FASTENERS AND MOUNTING SUPPORT SHALL BE ABLE TO WITHSTAND 250 LBS. POINT LOAD IN BENDING, SHEAR TENSION. ROTATION IN FITTING NOT ALLOWED.

1.

PROJECT LOCATION

TISSUE DISPENSER

44" MAX.

24"

18" MIN.

SOAP DISPENSER

12"

24"

CONT. TILE BEHIND MIRROR

33"-36" TO FIN. FLOOR

PAPER TOWEL DISPENSER

ROBE HOOK

MAX.

44"

MAX.

44"

48"

MAX.

13 1/2" MIN.

2. BARS SHALL BE 1-1/4" TO 1-1/2" IN DIAMETER WITH 1-1/2" CLEARANCE TO WALL.

WALL HUNG LAVATORY

39" MIRROR 40" MAX.

C L

MIRROR. SEE SPEC's.

18"

39" - 41"

GENERAL NOTES

NOTES: GRAB BARS AT WATER CLOSET (511.1A-9) 1. ONE AT SIDE 42" LONG EXTENDING 24" IN FRONT OF WATER CLOSET; ONE AT REAR OF WATER CLOSET 36" LONG; BOTH MOUNTED 33" ABOVE FINISH FLOOR. (EXCEPTION: REAR GRAB BAR OVER TANK TYPE WATER CLOSER MAY BE UP TO 36" ABOVE FINISH FLOOR)

NOTE: CONTRACTOR TO PROVIDE APPROPRIATE BLOCKING IN WALL FOR ANCHORAGE OF GRAB BARS AS REQUIRED.

A

H

DATE 2018.11.28 PROJECT NUMBER A2049

D

TYP.

SS-1

CT-1

N

ELEVATION - E

SCALE 1/4" = 1'-0"

5

ENLARGED FLOOR PLAN

C COPYRIGHT 2018 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.

SCALE 1/4" = 1'-0"

1

SHEET NUMBER

A6.1


FINISH SCHEDULE

OPEN SEATING AREA

BAR AREA

10'-0" A.F.F

PT-4

9'-0" A.F.F.

105

48" (V.I.F.)

(N) DOOR BEYOND

(N) BASE MILLWORK PROVIDED BY OWNER, TYP.

RB-1

RB-1

SCHEDULED BASE,TYP.

SCHEDULED BASE,TYP.

(N) INTERIOR ELEVATION @ TOILET RM.

SCALE

8

3/16" = 1'-0"

107 13'-0" A.F.F.

102

MEN'S TOILET ROOM

1911 HRC ULTIMA BEVELED TEGULAR

CF-1

CONCRTE FLOOR

T.B.D.

T.B.D.

CP-1

ARTIFICIAL GRASS

ORYZON GRASS

X-TINGUISH #7040

DEEP GREEN

13.2' x 115.5'

CP-2

CARPET

ALADDIN COMMERCIAL

TOWN CENTER II #1E73

T.B.D.

SANTARD ROLL

FRP

FIBER REINFORCED PLASTIC

MARLITE STD.

T.B.D.

S1000G-WHITE

(N) INTERIOR ELEVATION @ BAR AREA

SCALE 3/16" = 1'-0"

7

+22'-6" (E) CEILING HEIGHT

9483 HAVEN AVE, SUITE 100

T.B.D.

T.B.D.

PT-1

PAINT

DUNN EDWARDS

PT-2

PAINT

DUNN EDWARDS

#6381

COLOR SILVER BULLET

PT-3

PAINT

T.B.D.

T.B.D.

T.B.D.

PT-4

PAINT

T.B.D.

T.B.D.

T.B.D.

PT-5

PAINT

T.B.D.

T.B.D.

T.B.D.

SS-1

EDGE PROTECTION PROFILE

SCHLUTER SYSTEMS

T.B.D.

T.B.D.

SS-2

EDGE PROTECTION PROFILE

SCHLUTER SYSTEMS

T.B.D.

T.B.D.

SV-1

SHEET VINYL

FLOORING GROUP

CLASSICS (V5000)

ESTABLISHED 1002

9" x 48"

T-1

TILE

ARIZONA TILE

RECTIFIED COLOR BODY PORCELAIN DIGITAL PRINT

RESIDE SERIES BEIGE

12" x 24"

T-2

TILE

ARIZONA TILE

T.B.D.

T.B.D.

6" x 6"

VB-1

VINYL BASE

T.B.D.

T.B.D.

T.B.D. BY TENANT

QT-1

QUARRY TILE

ARIZONA TILE

TOWN CENTER II #1E73

T.B.D. BY TENANT

QTB-1

QUARRY TILE

T.B.D.

T.B.D.

T.B.D. BY TENANT

RB-1

RESILIENT BASE

VPI

PREMIUM WALL BASE STRAIGHT BASE

COLOR: 35 GRAPHITE

WHITE SEMI-GLOSS ENAMEL COLOR TO BE SELECTED BY OWNER

T.B.D.

PT-2 PT-5

PT-4

PT-4

TODDLER ZONE

102

1.

PROVIDE 6" x 1/8" THICK (STRAIGHT BASE) & 9" x 1/8" THK. @ F-2A / F-2D FIXTURE TOE SPACES - BY GENERAL CONTRACTOR

2.

INSTALL FRL-1 AND TRIM FROM THE FRONT OF THE CONVEYOR TO THE BACK OF WALL BEHIND AGENT COUNTER TO AVOID DAMAGE TO DRYWALL

3.

PROVIDE PAINT (P-1) AND RESILIENT BASE (RB-1) ON EXISTING VESTIBULE WALLS WHERE OCCUR. UNLESS OTHERWISE NOTED

4.

CARPET PATTERN TO RUN CONTINUOUSLY FRONT TO BACK

5.

ENSURE THAT THERE ARE NO GAPS BETWEEN CARPET TILES

www.AmorArch.com LOS ANGELES | LAS VEGAS | ATLANTA

OWNER

9700 WESTCHASE, LLC, A DELAWARE LIMITED LIABILITY COMPANY TENANT INTERIOR WORK

6.

WALL BASE AND FIXTURE BASE IS THE SAME SPEC, PROVIDED & INSTALLED BY G. C.

6" x 6"

1/8" THICK 6" HIGH 9" HIGH

PROVIDE BASE BEHIND ALL FIXTURES ALONG WALLS IN CUSTOMER LOBBY. FOR 9" BASE - CUT A 6" BASE TO 3" (SEE BASE DETAIL)

7.

ENSURE THAT THE BASE INSTALLED ON WALLS AND FIXTURES IS SMOOTH, AND DOES NOT HAVE GAPS BETWEEN INSTALLED LENGTHS AND IS NOT LIFTING

8.

WALL AND FIXTURE BASE SHOULD ONLY BE GLUED, DO NOT INSTALL WITH SCREWS OR NAILS

9.

ENSURE THAT ALL PAINT EDGES ARE STRAIGHT

10. GENERAL CONTRACTOR TO REPLACE ALL VISIBLE ELECTRICAL AND CONVENIENCE / DATA OUTLETS AND SWITCH PLATES TO GRAY COLOR 11. CONTRACTORS TO USE TACTILE GLUE FREE ADHESIVE FOR INSTALLATION AS RECOMMENDED BY CARPET MANUFACTURER SELECTED

107

9'-0" A.F.F.

104 OPEN BEYOND

CABINET BASE (BY OTHER)

24" TYP.

+0'-0" FINISH FLOOR (N) CABIBET MILLWORK BY OTHER, TYP.

24"

(N) WATER FOUNTAIN, SEE SHEET A1.1

SCALE

(N) INTERIOR ELEVATION @ ENTRY/ BAR AREA

3/16" = 1'-0"

PROTECTIVE CORNER BEAD

3" MAX. CLEAR

6

T-2 SEE FINISH SCHEDULE

QUARRY TILES FLOOR AND COVE BASE PER FINISH SCHEDULE

6"

RB-1 SCHEDULED BASE,TYP.

24" TYP.

3"

(N) DUTCH DOOR, TYP.

P. 909.259.9971 | F. 909.944.8409

VESTIBULE

48" (V.I.F)

13'-0" A.F.F.

101

BAR AREA

9'-0" A.F.F.

12'-0" A.F.F. SUSPENDED CEILING

ENTRANCE LOBBY

PT-2

(N) SS LED LIGHT FIXTURE, TYP.

RANCHO CUCAMONGA, CA 91730

GYP. BRD. OVER METAL STUD FRAMING @ 16" O.C.

CONSULTANT

GENERAL WALL

10'-0" A.F.F.

(E) STRUCTURAL TRUSS, TYP.

(E) STRUCTURAL COLUMN, BEYOND.

W.R. GYP. BRD.

GYPSUM BOARD

NOTES:

(N) SS LED LIGHT FIXTURE, TYP.

1 2"

GB-1

+0'-0" FINISH FLOOR (N) DUTCH DOOR, TYP.

INSTALL WITH PVC TRIM-WHITE

PROJECT LOCATION

10'-0" A.F.F.

TODDLER ZONE 12'-0" A.F.F. SUSPENDED CEILING

112

ARMSTRONG CEILINGS

(E) CONCRETE SLAB

PAINTED 3/4" THICK PLYWOOD

INTERIOR ELEVATIONS AND FINISH SCHEDULE

PT-2

2' x 4' x 3/4"

ACOUSTIC CEILING TILE

(N) SS LED LIGHT FIXTURE, TYP.

PT-5

WHITE GRID FACE: 15/16" - WHITE LAY-IN

ACT-1

NOTES

6" MIN. CLEAR

PT-4

PT-2

(E) STRUCTURAL TRUSS, TYP.

DIMENSION

SHEET TITLE

(E) STRUCTURAL COLUMN, BEYOND.

COLOR

15135 NORTH FREEWAY, HOUSTON, TEXAS 77042

(N) SS LED LIGHT FIXTURE, TYP.

(E) STRUCTURAL TRUSS, TYP.

PT-2

TYP. 3 A6.2

PRODUCT

TENANT IMPROVEMENT GARDEN CENTER SUITE #800

+22'-6" (E) CEILING HEIGHT

DESCRIPTION

MANUFACTURER

KIDS EMPIRE USA, LLC

CODE MATERIAL

--

STAMP

METAL TOP TRACK

PT-2 PT-5

PT-5

PT-5

3/4" = 1'-0"

4

CERAMIC FLOORING BAR

3" = 1'-0"

WIL L

SCALE

2

AT

PT-5

24" PAINTED 1x6 TRIM

(E) DOOR BEYOND TO REMAIN

(2) #10 SMS AT 6" O.C. 3"

+22'-6" (E) CEILING HEIGHT

CEILING JOIST PER PLAN

2 1 BEVEL

(E) FLOORING. VERIFY IN FIELD

REVISIONS 2018-12-20

ISSUED FOR PLAN CHECK

2018-12-20

ISSUED FOR HEALTH DEPT. PLAN CHECK

DATE 2018.11.28

ELEVATION SAME AS OPPOSITE

SEE REFLECTED CEILING PLAN

(N) INTERIOR ELEVATIONS @ DANCE ROOM AREA

E OF T EX

1/2" MAX

OPEN BEYOND

RESILIENT TRANSITION REDUCER BY 'JOHNSONITE' MODEL # EG-40-L - BLACK

3"

(E) DOOR BEYOND TO REMAIN

109

6" MIN.

107

PAINTED 3/4" THICK PLYWOOD

SEATING AREA

108 13'-0" A.F.F.

110

DANCE ROOM

SCHEDULED BASE,TYP.

RB-1 SCHEDULED BASE,TYP.

TODDLER ZONE

9'-0" A.F.F.

108

PLAY EQUIPMENT AREA

16 5 9 9

SHEETS BEARING THIS SEAL AND WET SIGNATURE ARE AUTHENTICATED. RESPONSIBILITY FOR ALL OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS ARE DISCLAIMED.

GLUE-DOWN CARPET DANCE ROOM

A

AS

CASTLE DETAIL

PT-2

13'-0" A.F.F.

Plotted: 12/20/2018 1:46 PM (jlavenant) File: 13_a2049_a6.2_interior elevations.dwg

PT-2

PT-2

SCALE

ST

(N) SS LED LIGHT FIXTURE, TYP.

(E) STRUCTURAL TRUSS, TYP.

IA

CT ITE

(E) STRUCTURAL TRUSS, TYP.

RED ARCH E T M A. R MO

+22'-6" (E) CEILING HEIGHT

REGI S

PAINTED 1x6 TRIM

SCALE 3/16" = 1'-0"

C COPYRIGHT 2018 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.

5

CASTLE DETAIL

PROJECT NUMBER A2049

EXISTING CONCRETE SLAB

METAL STUD WALL

SHEET NUMBER

SCALE 3/4" = 1'-0"

3

TRANSITION STRIP

SCALE 6" = 1'-0"

1

A6.2


FRP

FRP

FRP

FRP

TYP.

+12'-0" (N) CEILING HEIGHT

9483 HAVEN AVE, SUITE 100 RANCHO CUCAMONGA, CA 91730 P. 909.259.9971 | F. 909.944.8409 www.AmorArch.com LOS ANGELES | LAS VEGAS | ATLANTA OPEN BEYOND

OWNER

+0'-0" FINISH FLOOR T-2

T-2

T-2

ELEVATION - A

ELEVATION - B

T-2

9700 WESTCHASE, LLC, A DELAWARE LIMITED LIABILITY COMPANY TENANT INTERIOR WORK

ELEVATION - D

ELEVATION - C

NOTE: SEE SHEET A6.2 FOR FINISH SCHEDULE.

CONSULTANT

OPEN BEYOND

+0'-0" FINISH FLOOR RB-1

ELEVATION - A

RB-1

RB-1

ELEVATION - B

RB-1

ELEVATION - C

ELEVATION - D

NOTE: SEE SHEET A6.2 FOR FINISH SCHEDULE.

SCALE 3/16" = 1'-0"

1

STAMP

WIL L

ST

AT

IA

A

CT ITE

RED ARCH E T M A. R MO

REG IS

(N) INTERIOR ELEVATION @ DANCE ROOM

INTERIOR ELEVATIONS

KIDS EMPIRE USA, LLC

+12'-0" (N) CEILING HEIGHT

SHEET TITLE

GB-1

TENANT IMPROVEMENT GARDEN CENTER SUITE #800

GB-1

PROJECT LOCATION

GB-1

GB-1

2

16 5 9 9

AS

3/16" = 1'-0"

15135 NORTH FREEWAY, HOUSTON, TEXAS 77042

SCALE

(N) INTERIOR ELEVATION @ PANTRY AREA

E OF T EX

Plotted: 12/20/2018 1:48 PM (jlavenant) File: 14_a2049_a6.3_interior elevations.dwg

SHEETS BEARING THIS SEAL AND WET SIGNATURE ARE AUTHENTICATED. RESPONSIBILITY FOR ALL OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS ARE DISCLAIMED.

REVISIONS 2018-12-20

ISSUED FOR PLAN CHECK

2018-12-20

ISSUED FOR HEALTH DEPT. PLAN CHECK

DATE 2018.11.28 PROJECT NUMBER A2049

SHEET NUMBER

A6.3 C COPYRIGHT 2018 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.


+13'-0" A.F.F.

FRAMING NOTES

(E) DECK OR STRUCTURE UNDERSIDE OF (E) STRUCTURE ABOVE. (V.I.F.)

SCREW ATTACH, DIA. STRAPS TO EACH MTL. STUD CEILING JOIST FLANGE AND APPLY FIRE-RATED PLYWOOD ON TOP THRU-OUT A REQUIRED

(E) BUILDING EXTERIOR WALL R-11 SOUND INSULATION

PUNCHED "C" STUD HEADER. SEE SCHEDULE

2.

CARBON SHEET STEEL MUST MEET THE MINIMUM REQUIREMENTS OF ASTM A570 GRADE 50 KSI FOR 12 GAUGE ASTM A570 GRADE 50 KSI OR GRADE 33 KSI FOR 14 & 16 GAUGE AND GRADE 33 KSI FOR 18 GAUGE AND LIGHTER MEMBERS CARBON SHEET STEEL PRODUCTS MUST BE THOROUGHLY COATED WITH A RUST INHIBITIVE PAINT.

400T 162-54 UNPUNCHED "L" TRACK 3.

SET STUDS OFF 1/2" MIN., TYP.

PLAN SECTION

+12'-0" A.F.F.

NEW 1/2" GYP. BD. CEILING

OPENING WIDTH

HEADER SIZE

UP TO 6'-0"

550 S 162 - 43

6'-1" - 8'-0"

600 S 162 - 43

8'-1" - 10'-0"

600 S 162 - 54

(N) METAL STUDS @ 16" O.C. WITH R-13 INSULATION

4.

GENERAL CONTRACTOR TO ATTACH (SISTER) NEW CLARKDIETRICH STEEL FRAMING, 3 5/8" X 20 GA. METAL STUDS AT 24" O.C. FOR WALLS UP TO 18'-0" - TABLE, "ATI EVALUATION SERVICE" CODE COMPLIANCE RESEARCH REPORT NO. 'CCRR-0207' TO EXISTING METAL STUD FRAMING, FULL LENGTH OF STUDS AS REQUIRED.

3" = 1'-0"

#8 SMS @ 16" O.C., TYP.

5/8" GYP. BD. OVER 3 5/8" METAL STUDS

3 STUDS AT INTERSECTIONS SAME SIZE AS ADJACENT STUDS

NOTE: WHERE PLUMBING OCCURS PROVIDE 5/8" WATER RESISTANT GYPSUM BOARD

3 -

5.

ACCESSORIES: PROVIDE ALL ACCESSORIES INCLUDING, BUT NOT NECESSARILY LIMITED TO, TRACKS, CLIPS, WEB STIFFENERS, ANCHORS, FASTENING DEVICES RESILIENT CLIPS, AND OTHER ACCESSORIES REQUIRED FOR A COMPLETE AND PROPER INSTALLATION, AND AS RECOMMENDED BY THE MANUFACTURER FOR THE STEEL MEMBERS USED.

6.

FASTENING OF COMPONENTS SHALL BE WITH SELF-DRILLING SCREWS OR WELDING SCREWS OR WELDS SHALL BE OF SUFFICIENT SIZE TO INSURE THE STRENGTH OF THE CONNECTION. ALL WELDS OF GALVANIZED STEEL SHALL BE TOUCHED UP WITH A ZINC RICH PAINT. ALL WELDS OF CARBON SHEET STEEL SHALL BE TOUCHED UP WITH PAINT.

7.

PROVIDE A GOOD GRADE OF COMMERCIAL GROUT FOR LEVELING THE FLOOR RUNNER MEMBER OF STEEL STUD PARTITIONS AS REQUIRED.

CONSULTANT

CORNER

LOW HEIGHT PARTITION BRACING DETAIL

RD-TOILETRMDET

SCALE 3" = 1'-0"

7

SCALE

WALL FURRING

5

1 1/2" = 1'-0"

+13'-0" A.F.F.

TYP. STUD FRAMING

SCALE 1 1/2" = 1'-0"

2

+10'-0" A.F.F.

SCREW ATTACH, DIA. STRAPS TO EACH MTL. STUD CEILING JOIST FLANGE AND APPLY FIRE-RATED PLYWOOD ON TOP THRU-OUT A REQUIRED

SCREW ATTACH, DIA. STRAPS TO EACH MTL. STUD CEILING JOIST FLANGE AND APPLY FIRE-RATED PLYWOOD ON TOP THRU-OUT A REQUIRED

5/8" GYP. BD. BOTH SIDES

METAL STUDS PER SCHEDULE

PARTITION SCHEDULE 1.

ALL THE METAL STUDS USED SHALL BE "ICC-ES" TYPE OR APPROVED EQUAL.

2.

THE BRIDGING, BLOCKING OR END BEARING STIFFENERS SHALL BE AS REQUIRED BY THE MANUFACTURER UNLESS NOTED OTHERWISE ON THE DRAWINGS.

3.

ALL THE STUDS SHALL CONFORM TO "ICC-ES EVALUATION REPORT" ESR-3064P OR APPROVED EQUAL.

4.

UNLESS OTHERWISE NOTED ON THE PLANS, USE THE FOLLOWING GUIDELINE FOR STUD SIZE & SPACING FOR INTERIOR PARTITIONS.

5.

TOP TRACK SIZE WILL BE 20 GA. MINIMUM FOR PARTITION, U.N.O.

MAXIMUM PARTITION HEIGHT MAXIMUM PARTITION HEIGHT CONTINUOUS METAL BOTTOM TRACK WITH .145" x 1 1/4" MIN. HILTI FASTENERS @ 16" O.C. MAX. ICC ESR 1663

R-13 SOUND INSULATION CLARKDIETRICH STEEL FRAMING, 6" X 18 GA METAL CEILING STUDS @ 12" O.C. FOR SPAN UP TO 16'-2" TABLE, CEILING SPAN (S-SECTIONS), "ATI EVALUATION SERVICE" CODE COMPLIANCE RESEARCH REPORT NO. 'CCRR-0207'

CONTINUOUS METAL BOTTOM TRACK WITH .170" DIA. POWDER DRIVEN SHOT PIN WITH 1/2" EMBED (ICBO 1639) @ 24" O.C.

TOP OF EXISTING CONC. SLAB

EXIST. OPEN SPACE SIDE

GENERAL CONTRACTOR TO ATTACH (SISTER) NEW CLARKDIETRICH STEEL FRAMING, 3 5/8" X 20 GA. METAL STUDS AT 24" O.C. FOR WALLS UP TO 18'-0" - TABLE, "ATI EVALUATION SERVICE" CODE COMPLIANCE RESEARCH REPORT NO. 'CCRR-0207' TO EXISTING METAL STUD FRAMING, FULL LENGTH OF STUDS AS REQUIRED.

NEW 5/8" GYPSUM BOARD

NEW WATER RESISTANCE 5/8" GYP. BD. TO +48" A.F.F. INSIDE TOILET ROOMS ONLY.

CONTINUOUS METAL BOTTOM TRACK WITH .170" DIA. POWDER DRIVEN SHOT PIN WITH 1/2" EMBED (ICBO 1639) @ 24" O.C.

TOP OF EXISTING CONC. SLAB

NOTE:

1.

1.

SCALE 3" = 1'-0"

8

13' - 6"

550 S 125 - 30

16"

21' - 6"

24"

18' - 11"

600 S 125 - 30

16"

22' - 11"

24"

20' - 0"

SCALE 3" = 1'-0"

RD-TOILETRMDET RD-TOILETRMDET C COPYRIGHT 2018 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.

3" = 1'-0"

WIL L

3

METAL JOIST SCHEDULE

AT

1.

USE "ICC-ES EVALUATION REPORT" ESR-3064P OR APPROVED EQUAL.

2.

USE 600S125-43 @ 16" O.C. UP TO 16'-0" MAXIMUM SPAN WHERE CEILING SUPPORTED TOILET PARTITIONS OCCUR.

3.

STUD TRACKS SHALL BE UNPUNCHED STUDS OF SAME GAUGE AS STUD UNLESS NOTED OTHERWISE.

4.

ACOUSTIC CEILING TIES (SEE FINISH SCHEDULE) WITH 1 - #8 SCREWS AT EACH JOIST.

IA

A

16 5 9 9

E OF T EX

SHEETS BEARING THIS SEAL AND WET SIGNATURE ARE AUTHENTICATED. RESPONSIBILITY FOR ALL OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS ARE DISCLAIMED.

REVISIONS

CEILING TIES (BRACING) SPACING

SIZE

4' - 0"

MAXIMUM SPAN

MAXIMUM SPAN

SPACING

SPAN

SPACING

SPAN

362 S 125 - 30

16"

8' - 0"

24"

7' - 0"

3' - 6"

550 S 125 - 30

16"

11' - 0"

24"

9' - 0"

3' - 6"

600 S 125 - 30

16"

16' - 0"

24"

13' - 0"

2018-12-20

ISSUED FOR PLAN CHECK

2018-12-20

ISSUED FOR HEALTH DEPT. PLAN CHECK

PROJECT NUMBER A2049

SEE PARTITION AND CEILING BRACING ON THIS SHEET FOR ADDITIONAL INFORMATION.

TOILET ROOM PARTITION AND CEILING DETAIL

TYP. BOTTOM TRACK

SCALE

RED ARCH E T M A.

DATE 2018.11.28

ACOUSTICAL SEALANT AS REQUIRED, TYP.

NOTE:

PANTRY RM. PARTITION AND CEILING DETAIL

24"

NEW TOILET ROOM SIDE

ACOUSTICAL SEALANT AS REQUIRED, TYP.

SEE PARTITION AND CEILING BRACING ON THIS SHEET FOR ADDITIONAL INFORMATION.

15' - 6"

CT ITE

NEW WATER RESISTANCE 5/8" GYP. BD. TO +48" A.F.F. INSIDE PANTRY/STOR. ROOMS ONLY.

16"

NEW 1/2" GYP. BD. CEILING

R-13 SOUND INSULATION

NEW 5/8" GYPSUM BOARD

362 S 125 - 30

STAMP

+11'-0" A.F.F.

HEAVY DUTY SUSPENDED T-BAR CEILING, SPLAYWIRES TO BE BRACED TO BOTTOM OF CEILING MTL. JOIST, TYP.

HEIGHT

ST

GENERAL CONTRACTOR TO ATTACH (SISTER) NEW CLARKDIETRICH STEEL FRAMING, 3 5/8" X 20 GA. METAL STUDS AT 24" O.C. FOR WALLS UP TO 18'-0" - TABLE, "ATI EVALUATION SERVICE" CODE COMPLIANCE RESEARCH REPORT NO. 'CCRR-0207' TO EXISTING METAL STUD FRAMING, FULL LENGTH OF STUDS AS REQUIRED.

SPACING

R MO

NEW PANTRY/ STOR. ROOM SIDE

EXIST. OPEN SPACE SIDE

+9'-0" A.F.F.

HEIGHT

REG IS

+12'-0" A.F.F.

FINISH FLOOR SURFACE

SPACING

GYPSUM BOARD CEILING

CLARKDIETRICH STEEL FRAMING, 6" X 18 GA METAL CEILING STUDS @ 12" O.C. FOR SPAN UP TO 16'-2" TABLE, CEILING SPAN (S-SECTIONS), "ATI EVALUATION SERVICE" CODE COMPLIANCE RESEARCH REPORT NO. 'CCRR-0207'

SIZE

SHEET TITLE

9

PAINTABLE FIRE-STOP CONTINUOUS SEALANT AS REQUIRED

AS

SECTION

SEE PARTITION AND CEILING BRACING ON THIS SHEET FOR ADDITIONAL INFORMATION.

WALL AND MISCELLANEOUS DETAILS

3 STUDS AT INTERSECTIONS SAME SIZE AS ADJACENT STUDS

SCHEDULED WALL BASE

NOTE:

Plotted: 12/20/2018 1:49 PM (jlavenant) File: 15_a2049_a7.1_details & wall types.dwg

9700 WESTCHASE, LLC, A DELAWARE LIMITED LIABILITY COMPANY TENANT INTERIOR WORK

18 GA. BOTTOM TRACK

ACOUSTICAL SEALANT AS REQUIRED, TYP.

3" = 1'-0"

USE ONLY ONE TYPE THROUGHOUT THE WORK, UNLESS OTHERWISE SHOWN ON THE DRAWINGS OR SPECIFICALLY APPROVED IN ADVANCE BY THE ENGINEER AND/OR ARCHITECT.

SIM.

#8 SMS @ 16" O.C., TYP.

SCALE

OWNER

SCHEDULED FLOOR FINISH, TYP.

TOP OF EXISTING CONC. SLAB

DANCE ROOM PARTITION AND CEILING DETAIL

LOS ANGELES | LAS VEGAS | ATLANTA

www.AmorArch.com

INTERSECTION

SCHEDULED BASE, TYP.

1.

1

(N) 5/8" TYPE "X" GYPSUM BOARD · 6" ABOVE DROPPED CEILINGS, · OR FULL HEIGHT AT OPEN CEILINGS · END AT GYP. BOARD CEILINGS

STEEL TUBE BRACE @ ALL PARTITION ENDS AND 10'-0" O.C. AS REQUIRED. 1 1/2" X 1 1/2" STEEL TUBE SUPPORT WITH 1/4" X 2" X 5" BOTTOM PLATE WELD TO TUBE AND FASTEN TO SLAB WITH BOLTS AND CONC. ANCHORS

METAL BOTTOM RUNNER CONTINUOUS METAL BOTTOM TRACK WITH .170" DIA. POWDER DRIVEN SHOT PIN WITH 1/2" EMBED (ICBO 1639) @ 24" O.C.

SCALE

BOX HEADER

METAL STUDS AND / OR JOISTS: A. FOR METAL STUD WALLS, UNLESS OTHERWISE SHOWN ON THE DRAWINGS, PROVIDE STANDARD PUNCHED STEEL MEMBERS OF THE GAUGES SHOWN ON THE DRAWINGS.

P. 909.259.9971 | F. 909.944.8409

15135 NORTH FREEWAY, HOUSTON, TEXAS 77042

NEW 5/8" GYPSUM BOARD

METAL CORNER BEAD, TYP.

RANCHO CUCAMONGA, CA 91730

TENANT IMPROVEMENT GARDEN CENTER SUITE #800

R-11 SOUND INSULATION

PROVIDE METAL STUD BLOCKING AS REQUIRED FOR WALL MOUNTED EQUIPMENTS

ALL STRUCTURAL MEMBERS SHALL BE DESIGNED IN ACCORDANCE WITH AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS" 2010 EDITION WITH SUPPLEMENT 2.

B.

DANCE ROOM SIDE

9483 HAVEN AVE, SUITE 100

KIDS EMPIRE USA, LLC

EXIST. OPEN SPACE SIDE

RD-TOILETRMDET

GALVANIZED STEEL MUST MEET THE MINIMUM REQUIREMENTS OF ASTM A446 GRADE D (Fy=50KSI) FOR 12 GAUGE ASTM A446 GRADE A (Fy=33KSI) FOR 14 & 16 GAUGE ASTM A446 GRADE A (Fy=33KSI) FOR 18 GAUGE AND LIGHTER FOR THE ITEM AND USE INTENDED GALVANIZED COATINGS MUST MEET THE ASTM A525 SPECIFICATIONS.

PROJECT LOCATION

CLARKDIETRICH STEEL FRAMING, 6" X 18 GA METAL CEILING STUDS @ 12" O.C. FOR SPAN UP TO 16'-2" TABLE, CEILING SPAN (S-SECTIONS), "ATI EVALUATION SERVICE" CODE COMPLIANCE RESEARCH REPORT NO. 'CCRR-0207'

1.

SHEET NUMBER

6

A7.1


DOOR SCHEDULE

BUILDING STANDARD DOOR SEAL

ALUMINUM 1/2 SADDLE W/ WATER TIGHT SEALANT, BY PEMKO 1700 (OR EQUAL)

CONCRETE FINISH SEALED CONCRETE

SCHEDULED MARBLE THRESHOLD JOINT FLUSH WITH CERAMIC TILE

1/2" MAX

1/2" MAX.

CONCRETE SIDEWALK

DOOR

CERAMIC TILE

CONCRETE SLAB

SCALE

THRESHOLD DETAIL

14'-6" (V.I.F.)

3" = 1'-0"

T

T

T

T

T

T

T

9"

9"

3'-0" x 7'-0"

1-3/4"

C

GLZ

SS-1

1

ALUM.

SS-1

-

-

102

BAR AREA

3'-0" x 3'-3"

1-3/4"

B

S.C. WD.

SS-1

4

WD.

SS-1

-

4/A8.1

1 2 5 7

103

PANTRY

3'-0" x 7'-0"

1-3/4"

A

S.C. WD.

SS-1

2

WD.

SS-1

2/A8.1

1/A8.1

1 2 3 4 5 7 10 12 13

105

(E) MEN'S RSTRM

3'-0" x 7'-0"

-

-

-

-

-

-

-

-

-

1 3 4 5 6 8 14 15

106

(E)WOMEN'S RSTRM.

3'-0" x 7'-0"

-

-

-

-

-

-

-

-

-

1 3 4 5 6 8 14 15

107

TODDLER ZONE AREA

3'-0" x 7'-0"

-

-

-

-

-

-

-

-

-

19 10

107A

TODDLER ZONE AREA

3'-0" x 7'-0"

-

-

-

-

-

-

-

-

-

19 10

108

DANCE ROOM

3'-0" x 7'-0"

-

-

-

-

-

-

-

-

-

19 10

109

OPEN SEATING AREA

3'-0" x 7'-0"

-

-

-

-

-

-

-

-

-

10 17

111

LOBBY

3'-0" x 3'-3"

1-3/4"

B

LOBBY

3'-0" x 3'-3"

B

1-3/4"

SS-1

S.C. WD.

SS-1

S.C. WD.

G.C. TO VERIFY THAT EXISTING DOORS TO REMAIN ARE IN GOOD WORKING CONDITION. 2. ALL EXISTING DOORS TO REMAIN SHALL KEEP THE EXISTING HARDWARE U.N.O. OR FOUND TO NOT FUNCTION PROPERLY. G.C. TO CLEAN AND REPAIR HARDWARE TO AS-NEW CONDITION. 3. NEW BEST LOCK LEVER TYPE HARDWARE, FINISH TO MATCH EXISTING. G.C. TO VERIFY IN FIELD. 4. EXIT DOORS SHALL BE OPERABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. CBC 1010.1.9 5. G.C. TO PROVIDE SIGNAGE ON PRIMARY EGRESS DOORS STATING "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED." 6. ALL FINISH HARDWARE SHALL COMPLY WITH ALL GOVERNING CODES AND ACCESSIBILITY CODES. 7. ALL DOOR EDGES SHALL BE PRIMED AND PAINTED. VERIFY COLOR WITH INTERIOR ELEVATIONS. 8. G.C. SHALL PROVIDE A FLOOR MOUNTED DOOR STOP FOR DOORS THAT SWING AGAINST THE WALL. 9. ALL DOOR SILENCERS SHALL BE INSTALLED AFTER DOOR AND FRAME HAVE RECEIVED FINAL PAINTED. 10. INSTALL CAULKING AROUND DOOR FRAME JAMBS, HEAD AND AT BOTTOM OF FRAME. 11. DOOR OPENING FORCE: FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN, EXTERIOR OR INTERIOR HINGED DOORS WITH CLOSERS AND SLIDING OR FOLDING DOORS, SHALL NOT EXCEED FIVE POUNDS (22.2 N) MAXIMUM. 12. OVERHEAD AUTOMATIC SWITCH AIR CURTAINS MUST BE PROVIDED AT ALL DELIVERY DOORS. THE AIR CURTAIN WILL PRODUCE AN AIR FLOW (8) EIGHT INCHES THICK AT THE DISCHARGE OPENING AND WITH AN AIR VELOCITY OF NOT LESS THAN 1600 FPM (FEET PER MINUTE) ACROSS THE ENTIRE OPENING MEASURED AT THREE (3) FEET BELOW THE AIR CURTAIN.

10'-6"

9483 HAVEN AVE, SUITE 100 RANCHO CUCAMONGA, CA 91730 P. 909.259.9971 | F. 909.944.8409

WD.

SS-1

-

4/A8.1

1 7 13

www.AmorArch.com

3

WD.

SS-1

-

4/A8.1

1 7

LOS ANGELES | LAS VEGAS | ATLANTA

REMARK NOTES

SET #1: 3 EA 1 1 1 1 1 1

STOREFRONT DOOR HEAVY DUTY BUTT HINGES SELF CLOSER PANIC HARDWARE KEYED LOCKSET PUSH/ PULL PULL HANDLE FLOOR STOP

SET #2: 3 EA 1 1 1 1 1

PASSAGE DOOR - NON RATED BUTT HINGES SELF CLOSER DOOR STOP PUSH-PULL FLOOR STOP KICK PLATE

SET #3: 2 EA 1

1 9 10 12 15

4

1

DOOR HINGES: USE 3-1/2" SCREWS (ALL HARDWARE TO BE STAINLESS STEEL)

2

SIGNAGE: "EMPLOYEE ONLY" ON PASSAGE DOOR

4

PASSAGE DOOR - NON RATED SELF CLOSE BUTT HINGES BUZZER REMOTE LOCK

OWNER

DOOR CLOSER: HEAVY DUTY - AMERICAN DEVICE SERIES 6301 or LCN 4021 KICK PLATE, FULL WIDTH OF DOOR @ 10 INCH MIN HT. AT BASE (36" HT. AT IMPACT DOOR)

3

5

PROVIDE ACCESSIBLE IDENTIFICATION SYMBOLS

6

2'X4' VENT LOUVERS

7

ALL WOOD DOORS TO BE PREFINISHED "STAINED AT FACTORY". COLOR TO BE MATTE BLACK. G.C. TO INSTALL

8

HOLLOW METAL DOOR FRAME TO BE BLACK

9

CLEAN, REPAIR AS REQUIRED

10

EXTERIOR DOORS ARE SELF-CLOSING, AND RODENT PROOFED

9700 WESTCHASE, LLC, A DELAWARE LIMITED LIABILITY COMPANY TENANT INTERIOR WORK

CONSULTANT

EXISTING BUILDING EXIT DOOR REMAIN, NOT BE USED FOR EXIT NEW FRONT DOOR TO MATCH EXISTING WINDOW 12 MULLIONS 11

SET #4: 2 EA

PASSAGE DOOR - NON RATED SELF CLOSE BUTT HINGES

13 DUTCH DOOR WITH BUZZER REMOTE LOCK 14 SIGNAGE: "MEN" / "WOMEN" ON TOILET ROOM DOOR 15 BUILDING STANDARD DOOR SEAL AT STOREFRONT ENTRY DOOR. 7/A8.1

13. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS AND GATES THAT ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. (11B-309.4). OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MINIMUM AND 44" MAXIMUM ABOVE THE FINISH FLOOR OR GROUND (11B-404.2.7)

PANIC HARDWARE ON INTERIOR SIDE TYP. 10'-6"

PANIC HARDWARE ON INTERIOR SIDE TYP. 10'-6"

PANIC HARDWARE ON INTERIOR SIDE TYP.

9"

9"

T

9"

9"

4'-6" (V.I.F.)

4'-6"

TYP. 4'-6" (V.I.F.)

4'-6"

TYP. 4'-6" (V.I.F.)

T

6

6" = 1'-0"

14'-6" (V.I.F.)

9"

T

SCALE

REMARKS

FINISH HEAD JAMB

ENTRY

1.

MARBLE TRANSITION

14'-6" (V.I.F.)

MAT'L

DOOR NOTES AND HARDWARE

EQ. TO JAMB WIDTH

7

TYPE

FRAME

101

112

EXPANSION JOINT

SIZE

THK.

HDW. FINISH SET NO. MAT'L

16 MARBLE TRANSITION THRESHOLD AT MEN'S AND WOMEN'S TOILET ROOM. 6/A8.1 17

EXISTING REAR DOOR TO BE USED AS EXIT DOOR

T

T

T

T

T

T

2"

2X METAL FRAME

DOOR - PER SCHEDULE

DOOR CAP DOOR CAP 1" TYP.

T

T

T

T = TEMPERED GLASS

DUTCH DOOR JAMB

T

4 DUTCH DOOR JAMB LOCK

3" = 1'-0"

T = TEMPERED GLASS

5/8"

WIL L

16 5 9 9

E OF T EX

5/8" MIN. (TYP.)

5/8" MIN. (TYP.)

5/8" GYPSUM BOARD EACH SIDE

3/8" = 1'-0"

C COPYRIGHT 2018 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.

5

INTERIOR DOOR JAMB

SCALE

JAMB ANCHOR HOLLOW METAL FRAME 2"

2"

DATE 2018.11.28

STANDARD RABBET

DOOR - PER SCHEDULE

3" = 1'-0"

3

2018-12-20 ISSUED FOR HEALTH DEPT. CHECK CORRECTIONS 2 2018-09-10 PLAN PLAN CHECK

EXTEND GYP. BD. INTO FRAME 5/8" MIN.

INTERIOR DOOR HEAD

PROJECT NUMBER A2049 DOOR CAP

SHEET NUMBER

TYPE - B SCALE

2018-09-10 PLAN CHECK ISSUED FORCORRECTIONS PLAN CHECK 1 2018-12-20

METAL BOX BEAM

2"

WIDTH

PARTITION 2"

9"

HOLLOW METAL FRAME

5/8"

4'-10"

BUZZER - REMOTE UNLOCK WITH ELECTRONIC LOCK. VERIFY WITH TENANT FOR EXACT LOCATION AND REQUIREMENTS.

5/8" GYPSUM BOARD EACH SIDE

1/2" EACH SIDE

SELF CLOSE BUTT HINGE, TYP.

48" (V.I.F.)

PER SCHEDULE 4'-6"

AT

A

REVISIONS

2"

2"

4'-6"

DOOR AND WINDOW TYPES

2

IA

SHEETS BEARING THIS SEAL AND WET SIGNATURE ARE AUTHENTICATED. RESPONSIBILITY FOR ALL OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS ARE DISCLAIMED.

DOOR - PER SCHEDULE

TYPE - A

RED ARCH E T M A.

WIDTH

PER SCHED.

10" x WIDTH OF DOOR STAINLESS STEEL KICK PLATE WHERE OCCUR, TYP.

3" = 1'-0"

PARTITION

TYPE - E

TYPE - D

TYPE - C Plotted: 12/20/2018 2:56 PM (jlavenant) File: 16_a2049_a8.1_dr and wndw sched.dwg

T

SCALE

ST

T = TEMPERED GLASS

T

1/2" EACH SIDE

T

SCALE

REG IS

10'-6" V.I.F.

10'-6"

T 1'-3"

T

STAMP

DOOR CAP

CT ITE

T

1" TYP.

5/8" GYPSUM BOARD EACH SIDE

R MO

4'-6"

10'-6"

PANIC HARDWARE ON INTERIOR SIDE TYP.

5/8" GYPSUM BOARD EACH SIDE

TENANT IMPROVEMENT GARDEN CENTER SUITE #800

2X METAL FRAME

KIDS EMPIRE USA, LLC

4'-6" (V.I.F.)

T

2"

PROJECT LOCATION

9"

T 9"

T

4'-6" (V.I.F.)

4'-6"

TYP. 4'-6" (V.I.F.)

4'-6"

TYP.

9"

T

DOOR - PER SCHEDULE

14'-6" (V.I.F.)

PARTITION

14'-6" (V.I.F.)

1 3/4"

14'-6" (V.I.F.)

BUZZER REMOTE UNLOCK

1 3/4"

SELF-CLOSE BUTT HINGE

1/2" EACH SIDE

T = TEMPERED GLASS

EXIST. TYPE - E

WIDTH

T = TEMPERED GLASS

EXIST. TYPE - D

T

PARTITION

T = TEMPERED GLASS

EXIST. TYPE - C

T T

WIDTH

T

1/2" EACH SIDE

T

4'-6"

T

1'-3"

T

4'-6"

T

1'-3"

T

1'-3"

T

4'-6"

14. ALL NEW DOORS MUST BE EQUIPPED WITH LEVEL TYPE HANDLE.

DOOR SCHEDULE, HARDWARE NOTES AND DETAILS

WALL BEYOND

DOOR

ROOM NAME

SHEET TITLE

NO.

DOOR JAMB

AS

INTERIOR

15135 NORTH FREEWAY, HOUSTON, TEXAS 77042

EXTERIOR

-

SCALE 3" = 1'-0"

1

A8.1













Pantry Specifications

835 Mission St South Pasadena CA 91030 Phone: 626-799-4400


Prepared by: John Cataldo Architects 10/10/2018

PANTRY Equipment List & Quantity ITEM NAME

Washer/Dryer

Commercial Microwave Oven

MANUFACTURE

LG

PANASONIC

Model

FINSH

WM3997HWA

NE-1054

DIMENSIONS

Chrome Square Rimmed 27" x 38 11/16" x 29 3/4" Glass Door w/Dark Blue (51" H with door open) Tinted Cove

POLISHED SILVER

20"W X 12"H X 15"D

Ice Cream Chest

AHT USA INC.

RIO H 680-150

Inner tank made of white, pre-painted, galvanised steel

24"W X 35"H X 26"D

Refrigerators & Freezers

AVANTCO REGRIGERATION

178SS1RHC

POLISHED SILVER

29"W X 82.5"H X 33"D

Stainless Steel Kitchen Restaurant Work Prep Table w/Backspash

Glass Door Merchandiser: Swing Door Refrigerator

GRIDMAN

TRUE

REST-PREP-GR22BT2460

SILVER

GDM-26

Exterior - non-peel or chip white laminated vinyl; durable and permanent.

60 IN. X 24 IN.

30"W X 30"D X 79"H

Page 1 of 1

DISCRIPTION

4.5 cu.ft. Ultra Large Capacity All-In-One Washer/Dryer Combo w/ TurboWash®

—1000* Watts of Power —Capacity: 0.8 Cubic Feet —“Grab & Go” Door Handle —Bottom Energy Feed —Fits One 6" Tall, Half-Size Steam Table Pan with Cover

QUANTITY

1

2

• Adjustable thermostat • Reinforced insulation (2.83 in) for high "R" value and low energy consumption • Inner tank made of white, pre-painted, galvanised steel • Suitable for climate class 3 to climate class 7

1

Solid Door Reach-In Refrigerators & Freezers

2

—18-gauge #430 stainless steel —NSF certified —heavy-duty top with a 1-1/4″ tall backsplash

Extra large evaporator coil balanced with higher horsepower compressor and large condenser; maintains cabinet temperatures of 33°F to 38°F (.5°C to 3.3°C).

8

2

COMMENTS


4.5 cu.ft. Ultra Large Capacity All-In-One Washer/Dryer Combo w/ TurboWash®

WM3997HWA COMBINATION OF VERSATILITY AND EFFICIENCY Although it’s a space saving solution, this 27 inch wide washer/ dryer combination doesn’t compromise on capacity, with an ultra large 4.3 cubic foot tub. It comes equipped with the TrueBalance™ Anti-Vibration System, minimizing noisy tub movement, along with TurboWash® technology saving you 20 minutes on larger loads*. It also features an internal heating element with a NSF-certified Sanitary cycle, just a few more reasons this small washer/dryer combo comes with huge cleaning and space-saving benefits. INNOVATIONS

• 4.3 cu. ft. Ultra Large Capacity with NeveRust™ Stainless Steel Drum • Direct Drive Motor with 10-Year Limited Warranty • 1,300 RPM • 14 Washing Programs • 5 Temperature Settings (All Cold Rinses)

• CEE Tier 1 • Ventless Condensing Drying • Steam Technology • AAFA Certified Sanitary Cycle • NSF Certified Sanitary Cycle • ColdWash™ Option • 6Motion™ Technology • SmartDiagnosis™ • TrueBalance™ Anti-Vibration System • Magnet Ventilation • LoDecibel™ Quiet Operation • SenseClean™ • 10° TilTub™

STYLISH DESIGN

EP

C

ENDEN

ER

Y TL

I ND

• Upfront Electronic Control Panel with Dual LED Display and Dial-A-Cycle™ • Chrome Square Rimmed Glass Door with Dark Blue Tinted Cover • Extra Wide Door Opening • Optional Matching Drawer Pedestal

D™

SPECIFICATIONS

TIFI

E

TurboWash® Technology

Ultra Large Capacity

Ventless Condensing Drying System

Tired of spending hours on end finishing your family’s laundry? Now, those days are gone. LG’s revolutionary TurboWash® Technology allows you to save 20 minutes on larger loads*, with outstanding cleaning performance! It’s like pressing the fast forward button on your laundry.

Towers of towels, piles of sweatshirts, and a mountain of jeans? Go for it. The ultra large capacity (4.3 cu.ft.) tub lets you do more laundry in fewer loads. That’s time saved and sore backs avoided.

This combo washer and dryer is ideal if you don’t have an external venting source, which is required by most conventional dryers. Perfect for homes, apartments, businesses and vacation homes where space is valuable.

* Based on AHAM-HLW-1-2010 test protocol. Cotton/Normal or comparable cycle at default settings, 8-lb loads, front load washers only. Excludes other LG manufactured products. Excludes quick wash or comparable cycles intended for small, lightly soiled loads only.


4.5 cu.ft. Ultra Large Capacity All-In-One Washer/Dryer Combo w/ TurboWash®

WM3997HWA CAPACITY

MOTOR AND AGITATOR

Capacity

4.3 cu. ft.

APPEARANCE Design Look Front Control Intelligent Electronic Controls with Dual LED Display • Dial-A-Cycle™ •

ENERGY CEE Tier

1

WASH PROGRAMS No. of Programs 8 Wash Programs Cotton/Normal, Bulky/Bedding, Perm. Press/Casual, Speed Wash, Heavy Duty, BrightWhites™, Wool, Tub Clean No. of Options 12 Options Rinse+Spin, Spin Only, StainCare™, Soak, ColdWash™, Extra Rinse, Fabric Softener, Delay Wash, Child Lock, Custom Program, Signal On/Off, Water Plus No. of Wash/Rinse Temps Hot, Warm, Eco Warm, Cold, Tap Cold (All Cold Rinses) Spin Speeds Extra High (1100 max.), High, Medium, Low, No Spin No. of Water Levels Automatically adjusts to the size of load No. of Soil Levels 3

DRY PROGRAMS Sensor Dry Manual Timed Dry

More Dry, Normal Dry, Damp Dry, Low Temp Dry 30, 60, 90, 120 mins

FABRIC CARE FEATURES WaveForce™ • SmartRinse™ Jet Spray System • ColdWash™ Option • SenseClean™ System •

Motor Type Direct Drive Motor Motor Speed Variable Max RPM 1,300 Axis Horizontal

MATERIALS AND FINISHES NeveRust™ Stainless Steel Drum • Cabinet PCM Control Panel Plastic Top Plate Painted Transparent Glass Door • Door Rim Large Square Chrome Rimmed Glass Door with Dark Blue Tinted Cover Available Colors White (W)

POWER SOURCE Ratings UL Listed Electrical Requirements 120V, 10 Amps Type Electric

OPTIONS Pedestal Pedestal (WxHxD)

DIMENSIONS Product (WxHxD) Carton (WxHxD) Weight (Product/Carton)

• Prewash, Main Wash (with Liquid detergent cup), Bleach, Fabric Softener • • • • • • • • • • 4 Adjustable Legs •

LG Electronics U.S.A., Inc. 1000 Sylvan Avenue Englewood Cliffs, NJ 07632 Customer Service and Technical Support: (800) 243-0000

LG.com

27" x 38 11/16" x 29 3/4" (51" H with door open) 29 1/2" x 42 1/4" x 31 1/4" 211 lbs/225.8 lbs

LIMITED WARRANTY 1 Year Parts and Labor, 10 Years Motor Lifetime on Drum

CONVENIENCE FEATURES Washer/Dryer Combo All-In-One 4 Tray Dispenser TrueBalance™ Anti-Vibration System SmartDiagnosis™ LoadSense Status Indicator(s) End of Cycle Signal Child Lock Auto Suds Removal Forced Drain System Internal Water Heater LoDecibel™ Quiet Operation Leveling Legs Easy Loading TilTub™

WDP4W 27" x 13 3/5" x 28 2/5"

UPC CODES WM3997HWA

048231 014151

Design, features and specifications are subject to change without notice. Non-metric weights and measurements are approximate. © 2016 LG Electronics USA, Inc. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. All other product and brand names are trademarks or registered trademarks of their respective companies. 3/1/16


Commercial Microwave Oven NE-1054 This Commercial Microwave Oven by Panasonic is ideal for full and quick service restaurants, banquets, supermarkets, catering, and institutional applications.

—1000* Watts of Power —Capacity: 0.8 Cubic Feet —“Grab & Go” Door Handle —Bottom Energy Feed —Fits One 6" Tall, Half-Size Steam Table Pan with Cover


NE-1054 Commercial Microwave Oven Additional Features:

Specifications

• Compact Size

• Program List/Cycle Counter

• Stainless Steel Front

• Self Diagnostics

• Touch Control Keypad with Braille

• 99:99 Minute Capacity

• Beep Control (On/Off)

NE-1054 120V, 60Hz, Single Phase NEMA 5-15 R or Receptacle Required NEMA 5-20 R Frequency 2,450MHz Required Power 13.4A Output 1000 Watts* Outer Dimensions (wxdxh) 201/8" x 169/16" x 12" Cavity Dimensions (wxdxh) 13" x 13" x 81/16" Net Weight 34 lbs. Shipping Weight 39 lbs. 24 x 183/4 x 143/4, Shipping Box Size (wxdxh) 3.8 cu. ft. Timer 99 Min., 99 Sec. Memory Capability 20 Programs Power Source

• See-Through Oven Door

• Interior Oven Light • 10 Programmable Memory Pads; • Chef Technical Support 20 Memory Capability • Anti-Theft Equipped • 6 Power Levels • Will Ship via UPS • 2- and 3-Stage Cooking • NSF & UL Commercial • Programmable and Manual Approved Operations

Bottom Energy Feed The energy travels less distance to reach the food, compared to side or top energy feed, for increased efficiency.

“Grab & Go” Door Handle Without the hassle of moving parts like those found in push button doors or trigger-activated handles, the “Grab & Go” Door Handle is fast and durable.

Touch-Control Keypad Featuring an electronic keypad with 10 programmable memory pads and a 20-memory capability, the NE-1054 cooks with speed and precision with its 6 power levels and 2- and 3-stage cooking.

To Specify a Panasonic Commercial Microwave Oven The NE-1054 Commercial Microwave Oven meets or exceeds all safety performance and sanitation standards set for commercial food service microwave ovens by UL, DHHS, FCC and NSF. Plus, oven shall have output power 1000 Watts*, stainless steel front, bottom energy feed, 10 programmable memory pads, Braille keypad, 20-memory capability, Double Quantity Key, 6 power levels, 2- and 3-stage cooking, programmable lock, unique “quick pick” preset times and self-diagnostics, and Chef/Test Kitchen technical support. 3 years limited warranty. 1 year parts & labor. 3 years magnetron.

* I.E.C. 60705 Test Procedure. Specifications subject to change without notice.

Panasonic Home & Commercial Appliance Group Panasonic Corporation of North America Executives Offices: One Panasonic Way, Panazip 1H-2 Secaucus, NJ 07094 Design and specifications subject to change without notice.

Toll-free: 877-CMO-OVEN (266-6836) Sales Support, Recipes and Training at: www.panasonic.com/cmo For a Panasonic Distributor/Services nearest you, 1-800-350-9590

FS080512SS


ICE CREAM Ice cream chest. Ready to plug in.

Model RIO

Model SAO PAULO

More net volume – more sales.

www.ahtusainc.net


Designed with one thing in mind: Increased sales. A range of ice cream cabinets to meet

AHT ice cream cabinets can be placed everywhere. In a restaurant, convenience store, gas station, bar, supermarket... possibilities are endless. Quality and freshness of product are 100 % guaranteed in AHT ice cream cabinets.

Your advantages • AHT cabinets insure best visibility • Perfect product quality for your customers • Maximum net volume for increased sales


every retail opportunity.

RIO model. Designed to sell more ice cream by being visually appealing. Two different models – slanted with curved glass sliding lids and horizontal with flat glass sliding lids or solid lids permit perfect merchandise presentation and an excellent visibility. Choose the most suitable ice cream cabinet for your needs with a variety of options! You will be impressed by the practical, innovative and market-oriented cabinets – a result of our worldwide experience in the deep-freeze sector.

The SAO PAULO model. Ideal for ice cream and gelato scooping, available with an optional sneezeguard. Designed to maximize visual merchandising and ease of use. Can also be an ideal freezer for other uses such as product merchandising or bulk product storage.

Zubehör* • Seitenabdeckung für die Blockaufstellung • Leuchtaufsatz in verschiedenen Ausführungen • Trennwandgitter und Stellroste zur verkaufsaktivierenden Warenpräsentation • Stoßschutzleisten farbig nach Ihren individuellen Vorgaben • Sortimentsbeschriftung Produktgruppenschilder zum einfachen Aufstecken • Wasserschutzleisten Schutz vor Wasser und Staub unter dem Gerät

www.ahtusainc.net


RIO Key benefits • Excellent product visibility • Ready to plug in •E asy-to-move, curved or flat glass sliding lids with internationally patented, one-piece injected AHT lid frame • Low energy consumption • Adjustable thermostat •R einforced insulation (2.83 in) for high "R" value and low energy consumption • Inner tank made of white, pre-painted, galvanised steel • Very low maintenance •M odular system: same height and depth, different lengths available • Suitable for climate class 3 to climate class 7

Temperature range • Freezing: 7 °F to –9 °F


Enhance sales by adding an attractive decal to maximize retail merchandising!

Options and accessories*

Zubehör*

die Blockaufstellung • External or internal thermometer­available • Seitenabdeckung • Baskets and für dividers

• Light canopy

• Leuchtaufsatz in verschiedenen Ausführungen • Lock • Trennwandgitter und Stellroste zur verkaufsaktivierenden Warenpräsentation • Built-in rivnuts • Stoßschutzleisten farbig nach Ihren individuellen Vorgaben for mounting fixtures, canopies, etc.

* Available at extra charge.

* Fordern Sie unseren Zubehörfolder an.

• Defrost water drain • Internal light

• Sortimentsbeschriftung Produktgruppenschilder zum einfachen Aufstecken • Electrical frame heating • Insulated lids available for horizontal cabinets for RIO S • Wasserschutzleisten Schutz vor Wasser und Staub unter dem Gerät

www.ahtusainc.net


SAO PAULO

Key benefits • One-piece plastic-top frame • Ready to plug in •E asy sliding, flat glass lids with patented, one-piece injected AHT lid frame • Low energy consumption •A djustable thermostat, perfectly suitable for a variety of product applications • Very low maintenance • A wide range of accessories and extras

Temperature range • Freezing: packed ice cream 7 °F to –9 °F / scooping ice cream 21 °F to –11 °F (please specify when ordering)


Enhance sales by adding an attractive decal to maximize retail merchandising!

Options and accessories* •E xternal or internal thermometer available • Defrost water drain • Light canopy •C anopy for classic scooping ice cream sales

• Basket and dividers • Lock • Built-in rivnuts for mounting fixtures, canopies, etc. • Insulated lids

* Available at extra charge.

www.ahtusainc.net


SAO PAULO Technical Data SAO PAULO H »Class 7«

68 G

100 G

125 G

150 G

175 G

100 S

125 S

150 S

175 S

Gross content

cu.ft.

5.8

10.4

13.9

17.5

21.0

10.0

13.5

17.0

20.4

Net content acc. to EN 23953

cu.ft.

4.7

8.4

11.5

14.6

17.6

8.9

12.0

15.1

18.2

Total display area (TDA)

sq.ft.

3.5

5.5

7.1

8.6

9.5

7L1

7L1

7L1

7L1

7L1

7L1

7L1

7L1

7L1

Ambient temperature range

°F

61 to 95

61 to 95

61 to 95

61 to 95

61 to 95

61 to 95

61 to 95

61 to 95

61 to 95

Inner temperature range (packed ice cream)

°F

7 to –9

7 to –9

7 to –9

7 to –9

7 to –9

7 to –9

7 to –9

7 to –9

7 to –9

Inner temperature range

°F

21 to –11

21 to –11

21 to –11

21 to –11

21 to –11

21 to –11

21 to –11

21 to –11

21 to –11

Sound pressure in 1 m distance

dB(A)

39

39

40

40

40

39

40

40

40

Nominal voltage/frequency

V/Hz

120/60

120/60

120/60

120/60

120/60

120/60

120/60

120/60

120/60

Nominal power consumption

W

210

210

260

320

440

210

260

320

440

Nominal current

A

4.9

4.9

6.0

6.0

8.6

4.9

6.0

6.0

8.6

Fuse protection

A

16

16

16

16

16

16

16

16

16

Classification acc. to EN 23953

(scooping ice cream)

Electrical Data

Protection class

IP 21

IP 21

IP 21

IP 21

IP 21

IP 21

IP 21

IP 21

IP 21

Energy consumption (at 86 °F)

kWh/24 h BTU/24 h

3.2 10921

3.8 12969

4.5 15358

5.6 19112

7.2 24572

2.0 6826

2.5 8532

3.2 10921

4.1 13992

Length of power supply cord

inch

68.9

68.9

68.9

68.9

68.9

68.9

68.9

68.9

68.9

R404A

R404A

R404A

R404A

R404A

R404A

R404A

R404A

R404A

Refrigerant charge

oz

4.6

5.3

6.0

6.3

6.7

5.3

6.0

6.3

6.7

Max. operating pressure

bar

30

30

30

30

30

30

30

30

30

Refrigeration Data Refrigeration type

Dimensions Length outside/inside

inch

26.7/20.9

39.3/33.5

49.1/43.3

59.0/53.2

68.8/63.0

39.3/33.5

49.1/43.3

59.0/53.2

68.8/63.0

Depth outside/inside

inch

27.9/22.1

27.9/22.1

27.9/22.1

27.9/22.1

27.9/22.1

27.9/22.1

27.9/22.1

27.9/22.1

27.9/22.1

Height outside

inch

34.7

34.7

34.7

34.7

34.7

34.7

34.7

34.7

34.7

Height inside

inch

28.4

28.4

28.4

28.4

28.4

27.6

27.6

27.6

27.6

Stacking height

inch

24.0

24.0

24.0

24.0

24.0

24.8

24.8

24.8

24.8

Net weight

lb

115

137

163

190

216

134

159

185

212

Gross weight

lb

130

163

161

181

203

232

(excl. packaging and internal accessories)

185 Paulo 207 H , 115V 236 Sao

(incl. packaging, excl. internal accessories) 39.29

Sao Paulo H100

Sao Paulo H100

22.05

12.0 34.65

20.87 Sao Paulo H 68 43.31 Sao Paulo H125 53.15 Sao Paulo H150 63.00 Sao Paulo H175

2.56

ISO 9001, ISO 14001

33.46

27.91

11.42

Stacking height

26.69 Sao Paulo H 68 49.13 Sao Paulo H125 58.97 Sao Paulo H150 68.82 Sao Paulo H175

www.ahtusainc.net


RIO Technical Data (S = angle-top version, H = horizontal version)

RIO »Class 7«

RIO S 68

RIO S 100

RIO S 125

Gross content

cu.ft.

4.7

8.4

11.4

Net content according to EN 23953

cu.ft.

3.6

6.7

9.1

Total display area (TDA)

sq.ft.

3.4

5.4

6.9

7L1

7L1

7L1

Classification according to EN 23953 Ambient temperature range

°F

61 to 95

61 to 95

61 to 95

Inner temperature range

°F

7 to –9

7 to –9

7 to –9

Sound pressure in 1 m distance

dB(A)

39

39

40

Electrical Data Nominal voltage/frequency

V/Hz

120/60

120/60

120/60

Nominal power cabinet

W

260

270

280

Nominal power illumination

W

40

40

40

Nominal current

A

4.9

4.9

6.0

Fuse protection

A

16

16

16

IP 21

IP 21

IP 21

Energy consumption (at 86 °F)

kWh/24 h BTU/24 h

4.0 13651

4.6 15699

5.1 17405

Length of power supply cord

inch

68.9

68.9

68.9

Protection class

Refrigeration Data Refrigerant type

R404A

R404A

R404A

Refrigerant charge

oz

4.2

4.9

5.6

Max. operating pressure

bar

30

30

30

Dimensions Length outside/inside

inch

26.8/20.9

39.4/33.5

49.2/43.3

Depth outside/inside

inch

25.6/19.7

25.6/19.7

25.6/19.7

Front access height/height outside

inch

30.2/34.7

30.2/34.7

30.2/34.7

Height inside front/rear

inch

24.0/28.4

24.0/28.4

24.0/28.4

Stacking height front/rear

inch

20.9/22.5

20.9/22.5

20.9/22.5

Net weight (excl. packaging and internal accessories)

lb

112

134

152

lb

121

148

168

Rio S , 115V

Gross weight (incl. packaging, excl. internal accessories)

RIO S 68 – 175 26.77 Rio 68

Rio 68

19.69 12.0

12.6

30.16

34.65

33.46 Rio 100 43.31 Rio 125 53.15 Rio 150 63.00 Rio 175

2.56

20.87

25.59

11.42

Load limit height

front 20.87 back 22.44

39.37 Rio 100 49.21 Rio 125 59.06 Rio 150 68.90 Rio 175

www.ahtusainc.net


RIO S 150

RIO S 175

RIO H 68 G

RIO H 100 G

RIO H 125 G

RIO H 150 G

14.3

17.2

5.2

9.3

12.4

15.6

11.6

14.0

4.1

7.6

10.3

13.0

8.4

9.9

3.1

5.0

6.4

7.9

7L1

7L1

7L1

7L1

7L1

7L1

61 to 95

61 to 95

61 to 95

61 to 95

61 to 95

61 to 95

7 to –9

7 to –9

7 to –9

7 to –9

7 to –9

7 to –9

40

43

39

39

40

40

120/60

120/60

120/60

120/60

120/60

120/60

370

440

260

260

270

340

40

40

no light

no light

no light

no light

6.0

6.6

4.9

4.9

6.0

6.0

16

16

16

16

16

16

IP 21

IP 21

IP 21

IP 21

IP 21

IP 21

7.1 24231

7.2 24572

4.0 13651

4.3 14675

4.7 16040

6.4 21842

68.9

68.9

68.9

68.9

68.9

68.9

R404A

R404A

R404A

R404A

R404A

R404A

6.0

6.3

4.2

4.9

5.6

6.0

30

30

30

30

30

30

59.1/53.2

68.9/63.0

26.8/20.9

39.4/33.5

49.2/43.3

59.1/53.2

25.6/19.7

25.6/19.7

25.6/19.7

25.6/19.7

25.6/19.7

25.6/19.7

30.2/34.7

30.2/34.7

34.7

34.7

34.7

34.7

24.0/28.4

24.0/28.4

28.4

28.4

28.4

28.4

20.9/22.5

20.9/22.5

24.0

24.0

24.0

24.0

170

194

117

143

163

181

187

207

126

179

196

Rio H , 115V 157

RIO H 68 – 150 26.77

Rio 68

Rio 68

19.69 12.0 34.65

33.46 Rio 100 43.31 Rio 125 53.15 Rio 150

12.6

2.56

20.87

25.59

11.42

Load limit height

front 24.01 back 24.01

39.37 Rio 100 49.21 Rio 125 59.06 Rio 150

a p p ro v e d a c c o rd i n g t o U L 4 7 1 a p p ro v e d a c c o rd i n g t o N S F / A N S I 7

Subject to technical modifications and typographical errors. Version: 08/2008

AHT Cooling Systems USA Inc. 1005 Bankton Drive · Hanahan · SC · 29410 · Tel. 866-248-8721 (toll free) or 843-266-1756 · Email sales@ahtusa.net · www.ahtusainc.net


11/2017

SS Series

Solid Door Reach-In Refrigerators & Freezers

www.AvantcoRefrigeration.com

MODEL #178SS1RHC

SS SERIES REACH-IN REFRIGERATOR

SPECIAL FEATURES

Keep ingredients within a safe temperature range in a sleek, durable, and easy-to-clean environment

• Self-closing door with convenient stay-open feature • Easy-to-clean 430 series stainless steel exterior • Corrosion-resistant 304 series stainless steel interior • Temperature range of 33-40°F

CABINET CONSTRUCTION

Heavy duty all-stainless steel construction includes corrosion-resistant 304 stainless steel interior and durable 430 stainless steel exterior. Foamed-in-place CFC- and HCFC-free polyurethane insulation enhances the structural integrity of the cabinet and helps increase energy efficiency. Removable one-piece grill simplifies cleaning and servicing. Stainless steel solid door has stay-open feature beyond 90˚ for easy loading, but will self-close under 90˚ to save energy. Each door is outfitted with an easy-to-grasp full length handle

REFRIGERATION SYSTEM

Environmentally-safe R290 refrigerant. Bottom-mounted condensing unit positioned for easy maintenance. “No stoop” lower shelf raises product to a higher level for easy access.

SHELVING

3 gray epoxy-coated steel shelves included. Each accommodates up to 120 lb.

MODEL FEATURES

Preprogrammed digital controls feature auto-defrost function. Shelf rails accommodate full size food pans for storage flexibility. Optional bun pan rails accommodate full size bun pans. Interior back panel separates shelf and back wall to promote proper airflow.

WARRANTY RESIDENTIAL: Avantco assumes no liability for parts or labor coverage for component failure, factory defect or any other damages for units installed in non-commercial foodservice or residential applications.

Parts & Labor

Compressor

• 3 shelves included; versatile shelf slide design also accepts

full size food pans • Environmentally-safe R290 refrigerant • Digital temperature controller with automatic defrost function • 115V; 1/5 HP • ETL Safety & Sanitation Listed


SS Series

Solid Door Reach-In Refrigerators & Freezers MODEL #178SS1RHC

www.AvantcoRefrigeration.com

TECHNICAL DATA Dimensions

Cooling

Exterior Dimensions

29"W x 32¼"D x 82½"H

Interior Dimensions

243/8"W x 271/8"D x 60¼"H

Temperature Range

33°F - 40°F

Refrigerant

R290

Net Volume

20.6 cu. ft.

Net Weight

282 lb.

Defrosting

321 lb.

Temperature Controller

Gross Weight Packaging Dimensions

Max. Ambient Temperature

30¼"W x 34"D x 84½"H

90°F Automatic Digital

Horsepower

Construction

1/5

Electrical

Exterior Material

430 Stainless Steel

Voltage

115

Interior Material

304 Stainless Steel

Amps

2.6

Hz

60

Insulation Material

Foamed-In-Place Polyurethane

Shelf Size

(3) 207/8”W x 253/16”D

Phase

Shelf Material

Epoxy-Coated Steel

Plug Type

Shelf Load Capacity

120 lb.

1 NEMA 5-15P

Electrical Cord Length

96”

PLAN VIEW FRONT VIEW 29”

SIDE VIEW

TOP VIEW

32¼”

29”

32¼”

3”

FROM WALL

77½” 82½”

5”

59”

NEMA 5-15P


012312456

789 8 ÿ 89

ÿ ÿ 9 ÿ ÿ 88 9 ÿ ÿ ÿ!ÿ" #ÿ$9% ÿ&1ÿ'9 # 9 ÿ(ÿ34ÿ ÿ)ÿ2*ÿ ÿ+ , 9 ÿ!ÿ - + , 9 ÿ!ÿ -

Ì ×ÿ Ü ÛÂÀ¿ ÿ ÕÇÇϽ»¿ÿÅÿÖÁ¾¿¾ ØÀ¼ÈÀ¾ ÙÀÁÚÈ º»¼½¾¿ÀÁÂÃÿÅÿÆÇÁÈ»¿ÁÉÁÇ 59% $ ÿ!ÿ4 9 , 8 9- Ê Ë9 9 ÿ!ÿ 9 ÿ < 8 , 9 49 9 ÿÌ9 = 49 9 4 9 & # = Í < ÿ ÿ

ÝÈÞÂÀ¿ÚÈ»¿¾

ÎÏ»ÏýýÿÐÑÒÓÔÿ

ÿ8

' & =ÿÌ Ê

?@ABCDEFGHÿJÿKLFM@DFNL¥OPPAÿKMEQFLMÿRSBFTUM@DÿJÿKBTTHFMC¥VPEWDGXHMCÿJÿVPEWCDGDFP@C

_EFAUG@@

_EFAUG@@ÿ̀KOÿKDGF@HMCCÿKDMMH aPUUMELFGHÿbFDLZM@ÿcEMTÿJÿVPEWÿdGXHM efÿgGLWCTHGCZÿhÿi\ÿF@jÿkÿ[lÿF@j ÿÿÿÿ[[mÿLBCDPUMEÿEMQFMeC nÿmlÿG@CeMEMAÿSBMCDFP@C cEFLMopqrljssÿ tuvÿwmxÿyEPUÿpqrljssÿ

z{u|}~| } ÿ ÿ } ÿ} u gEG@Aÿ̀GUM _EFAUG@@ aPHPE KFHQME R ` \ \[\ [ \ [lq `BUXMEÿPyÿ?DMUC q cGEDÿ̀BUXME Vdh[ll _g KF M i\ÿF@LZMCÿ P@ ÿkÿ[lÿF@ÿ MMT ca \[\ [ \ [lq

¦PHHÿPQMEÿFUG MÿDPÿ PPUÿF@ ÿÿÿÿ

KMMÿUPEMÿTEPABLDÿAMDGFHC aPUTGEMÿeFDZÿCFUFHGEÿFDMUC | } ÿ ÿ u u ÿ| u ÿG@AÿLG@@PDÿXMÿZFAAM@j

pqrljss O¦RRÿAMHFQME§ dZFCÿFDMUÿFCÿAMHFQMEMAÿQFGÿ EPB@A CZFTTF@ j

?@ÿKDPLWj

KPHAÿX§ÿ©FkÿVZPHMCGHMÿG@A OBHNHHMAÿX§ÿ UG P@jÿ_FyDheEGT GQGFHGXHMj ­D§o q ª««ÿ ÿ u| } ÿ ¬ÿ mh®MGEÿcEPDMLDFP@ÿcHG@ÿyPE pq ji\ [h®MGEÿcEPDMLDFP@ÿcHG@ÿyPE pqqjlr AAÿDPÿaGED dBE@ÿP@ÿqhaHFLWÿPEAMEF@ ÿyPEÿDZFCÿXEPeCME

MHFQMEÿDPÿaZEFCDF@Mÿhÿ ]P@PHBHBÿsi [rÿ

AAÿDPÿ FCD AAÿDPÿ§PBEÿ GCZÿgBDDP@C

ÿ¡¢ £¤ ÿ ¢£ ¤

Y

KZGEMÿ ÿ ÿ ÿ ÿ[\YÿKZGEMC

Y

dPDGHÿTEFLMoÿpmmrjs AAÿGHHÿDZEMMÿDPÿaGED AAÿGHHÿDZEMMÿDPÿ FCD

¯ u ÿzu u ÿ ÿª ° tuvÿwmxÿyEPUÿpqrljssÿ ]GQMÿP@MÿDPÿCMHH^

KMHHÿP@ÿ UG P@

± } ÿ} u ¬_EFAUG@@ÿ̀KOÿKDGF@HMCCÿKDMMHÿaPUUMELFGHÿbFDLZM@ÿcEMTÿJÿVPEWÿdGXHMÿefÿgGLWCTHGCZÿhÿi\ÿF@jÿkÿ[lÿF@jÿpqrljss _EFAUG@@ÿlÿF@LZÿaGCDMEÿVZMMHÿKMDÿOPEÿaPUUMELFGHÿbFDLZM@ÿcEMTÿdGXHMC²ÿ[ÿVZMMHCÿeFDZÿgEGWMC²ÿ[ÿeFDZPBD³ÿpr[j s _EFAUG@@ÿKDGF@HMCCÿKDMMHÿaPUUMELFGHÿbFDLZM@ÿcEMTÿJÿVPEWÿdGXHMÿeFDZÿgGLWCTHGCZ²ÿl ÿkÿ[lÿ?@LZMCÿpq[ j[\

´ µ ¢¶ µÿ·¤¢ÿ¡¢ £¤ ÿ ¤¸µÿ¸ ¶ÿ¹ µ¢ÿ¡¢ £¤

cG MÿqÿPyÿql

11&&& 989 81 1'45.$3/07/11 2+32 04 5' 6+70! 230674897:6605! 24! -;2 <; <; =; ; >- 9 , (%, (% -

516


012312456

789 8 ÿ 89

ÿ ÿ 9 ÿ ÿ 88 9 ÿ ÿ ÿ!ÿ" #ÿ$9% ÿ&1ÿ'9 # 9 ÿ(ÿ34ÿ ÿ)ÿ2*ÿ ÿ+ , 9 ÿ!ÿ -

iUMOjQNNÿlZQMNmTRRÿlZTTm nWjjTUYMQmÿoMZYpTNÿqUTV ^ÿrWUsÿtQumTÿSMZp wQYsRVmQRp\ÿ~ ÿ|ÿ}~ÿ NYpTR ÿ~ ÿwTRZÿlTmmTU ÿMN nWjjTUYMQmÿrWUsZQumTR QNO

iUMOjQNNÿklLÿlZQMNmTRR lZTTmÿnWjjTUYMQmÿoMZYpTN qUTVÿ^ÿrWUsÿtQumTÿSv wQYsRVmQRpÿxÿ }ÿMN{ÿ|ÿ}~ÿMN{ ÿ } { ÿ

iUMOjQNNÿklLÿlZQMNmTRR lZTTmÿnWjjTUYMQmÿoMZYpTN qUTVÿ^ÿrWUsÿtQumTÿ}ÿtMTU WXumTÿ `TURpTm[ÿxÿ~ ÿ z {

iUMOjQNNÿ ÿnWjVQUZjTNZ klLÿlZQMNmTRRÿlZTTm nWjjTUYMQmÿ NOTUuQUÿlMNs ÿ z ÿwTRZÿlTmmTU ÿMNÿtUMVmT wWSmÿoMZYpTNÿlMNsR

} ~{~ ÿ

iUMOjQNNÿklL lZTTmÿnWjjTU qUTVÿ^ÿrWUsÿt |ÿ zÿMN{ ÿ ÿW TUÿ[UWjÿ

} {}zÿ

ÿ ÿ ÿ ÿ ¡¢ ÿ¢ £ÿ¤¥¦§¨©ªÿ¨¦¬ª­®

iUMOjQNNÿlZQMNmTRRÿlZTTm nWjjTUYMQmÿoMZYpTNÿqUTV ^ÿrWUsÿtQumTÿSv wQYsRVmQRpÿxÿ } ÿ|{{{ ÿ z } { ÿ

iUMOjQNNÿklLÿlZQMNmTRR lZTTmÿnWjjTUYMQmÿoMZYpTN qUTVÿ^ÿrWUsÿtQumTÿSv~ nQRZTURÿ rpTT{{{ ÿ ~y } {y

qQ¯Tÿ ÿW[ÿ }

iUMOjQNNÿlZQMNmTRRÿlZTTm nWjjTUYMQmÿoMZYpTNÿqUTV ^ÿrWUsÿtQumTÿSMZp wQYsRVmQRp\ÿ~ ÿ|{{{ ÿ~ } {}zÿ

l kn ÿnWjjTUYMQm lZQMNmTRRÿlZTTmÿrWUsÿLWWO qUTVÿtQumTÿ~ ÿMNÿ°WN¯ÿ|ÿ}~ MNÿ TTVÿrvwQ{{{ ÿ z {

XUQlZTTmÿrWU lZQMNmTRRÿlZTTm z ÿ|ÿ ÿ|ÿ ~ rMZpÿ~ÿnQRZTUÿ ÿ z { ÿ

7 ÿ- %9 #

?@ABÿ@ÿDEBFGHIJK

LMNOÿQNRSTURÿMNÿVUWOXYZÿMN[W\ÿ]^_R\ÿUT`MTSR

aIbc@dBÿeHGfÿFHbHg@dÿHGBbF ÿ

hfHFÿHGBbÿiUMOjQNNÿklL lZQMNmTRRÿlZTTmÿnWjjTUYMQm oMZYpTNÿqUTVÿ^ÿrWUsÿtQumTÿSv wQYsRVmQRpÿxÿyzÿMN{ÿ|ÿ}~ÿMN{ _OOÿZWÿnQUZ aEFGIbBdÿ @GHJ

ÿ }} ÿ

iUMOjQNNÿlZQMNmTRRÿlZTTm nWjjTUYMQmÿoMZYpTNÿqUTVÿ^ rWUsÿtQumTÿSMZpÿwQYsRVmQRp\ ~ ÿ|ÿ}~ÿ NYpTR ÿwTRZÿlTmmTU

_OOÿZWÿnQUZ ÿ ~ ÿ

iUMOjQNNÿklLÿlZQMNmTRRÿlZTTm nWjjTUYMQmÿoMZYpTNÿqUTVÿ^ rWUsÿtQumTÿSvÿwQYsRVmQRpÿxÿ } MN{ÿ|ÿ}~ÿMN{ _OOÿZWÿnQUZ ÿ ÿ

iUMOjQNNÿlZQMNmTRRÿlZTTm nWjjTUYMQmÿoMZYpTNÿqUTVÿ^ rWUsÿtQumTÿSvÿwQYsRVmQRpÿx } ÿ|ÿ z _OOÿZWÿnQUZ ÿ z ÿ

11&&& 989 81 1'45.$3/07/11 2+32 04 5' 6+70! 230674897:6605! 24! -;2 <; <; =; ; >- 9 , (%, (% -

216


012312456

?@ABC DEAFFAGH DIJKÿMN DAZC

789 8 ÿ 89

ÿ ÿ 9 ÿ ÿ 88 9 ÿ ÿ ÿ!ÿ" #ÿ$9% ÿ&1ÿ'9 # 9 ÿ(ÿ34ÿ ÿ)ÿ2*ÿ ÿ+ , 9 ÿ!ÿ - è

£çbéé

è

£aea\

è

a£ééé

è

ageéé

OPQÿSTUVWXYVW [\ÿP]^TWXÿ_U]`ÿQÿabÿP]ÿcWWd

OPQÿSTUVWXYVW beÿP]ÿ_U]`ÿQÿabÿP]ÿcWWd

OPQÿSTUVWXYVW faÿP]^TWXÿ_U]`ÿQÿabÿP]ÿcWWd

OPQÿSTUVWXYVW faÿP]^TWXÿ_U]`ÿQÿg\ÿP]ÿcWWd

hijklmnÿpqrnliqs

tuvÿxyz{|}|y~ {z ÿ y ~ { ÿ{ ~y~ÿ}z {ÿ ~ÿ ÿy~ y ~ { yÿ y| {ÿ ~yz y } ~ { yÿ y| {ÿ zz| ÿ}yy{

?@IK B ÿKC B@AF AIG

TPXÿTWY ÿ Y VWÿ ÿ P ¡Y]]ÿPXÿ^U]X ^ W ÿ¢ U¡ÿ£e `Y `Wÿ¤bg\ÿX YP]VWXXÿX WWV¥ÿY] ÿPXÿ TWÿdW ¢W^ ÿ¦U §ÿX ¢Y^Wÿ¢U ÿ XWÿP]ÿYÿ§P ^TW]¥ÿ Y ¥ÿ WX Y Y] ¥ VY ] ¥ÿX^TUUV¥ÿTUXdP YV¥ÿU ÿY] ÿU TW ÿ^U¡¡W ^PYVÿXW P]`ÿ̈© ÿPXÿª«¬ÿ^W P­W ÿ Uÿ¡WW ÿX P^ ÿX Y] Y Xÿ¢U ÿd VP^ÿTWYV Tÿd U W^ PU]ÿY] ÿ PV ÿ¢U ÿTP̀T UV ¡Wÿ XW UÿVYX ÿYÿVP¢W P¡Wÿ̈ TPXÿ Y VWÿ¢WY WXÿY]ÿWQ YÿTWY ÿ Udÿ¦P TÿYÿ£ £®b¯ÿ YVVÿ Y^§XdVYXT¥ÿY]ÿY ° X Y VW TWP̀T ÿ̀YV Y]P±W ÿ ] W XTWV¢¥ÿY] ÿ̀YV Y]P±W ÿVW`X ¦P TÿY ° X Y VWÿ]U] ¡Y P]`ÿ¢WW ÿ TY ÿWVP¡P]Y Wÿ Y VWÿ¦U VWÿU]ÿ ]W W]ÿ²UU Xÿ̈ TWÿW `WXÿU]ÿ TWÿ¢ U] ÿY] ÿ Y^§ÿU¢ÿ TWÿ Y VW UdÿY Wÿ U ] W ÿ¢U ÿ¦U §P]` ^U¡¢U ÿ̈¬YX ÿY] ÿWYX ÿYXXW¡ V ÿ̈³VVÿ Y VWÿXP±WXÿY Wÿgb g®b¯ÿ YVVÿ́g[¯ÿ¦P Tÿ Y^§XdVYXTµÿ̈©]^V WX¶ÿ« YP]VWXXÿX WWVÿ Y VWÿ¦P Tÿ YXW¥ÿP]X ^ PU]X¥ÿY] ÿTY ¦Y Wÿ¢U YXXW¡ V ÿ̈··· TPXÿd U ^ ÿPXÿ WXP̀]W ÿY] ÿ­]PXTW ÿ¢U ÿ XWÿP]ÿYÿ^U¡¡W ^PYVÿW] P U]¡W] ÿ̈ TW W¢U WÿX ¢Y^WÿP¡dW ¢W^ PU]XÿX ^TÿYXÿX^ Y ^TWX¥ÿX^ ¸XÿY] ÿP] W] X ¡Y ÿ Wÿ¢U ] ÿ̈ TPXÿPXÿ]U ¡YVÿY] ÿ Uÿ WÿWQdW^ W ÿU]ÿd U ^ XÿU¢ÿ TPXÿ]Y W···

hijklmnÿkqnr¹ºs

»¼¹½½¹¾¿ÿÀq¹¿¼nÁÿÂÂÿ ~ ÿÃÄ|yÅÿ | | ÿz {y ÿ ~ÿ | |y Æ Ç»ÈÉÁÿÊËÌÍÎÂÏÄ Ï ÇÐqir¿qÿÑlsnjÒqiÿÓqйqÔÁÿ ÿ ÿÿÕÕÖÿ { yzÿzy |yÅ ÇÒr×j¾ÿØqsnÿ»qººqisÿÓr¾ÙÁÿÚÌÛÕÜÍÿ| ÿÝ ~ {z| ÿÞÿu |y {|}| ÿÃuyyÿÎ ÿÌËËÿ| ÿÝ ~ {z| ÿÞÿu |y {|}| Æ ÚÖÿ| ÿÝ ~ {z| ÿÞÿu |y {|}| ÿßÿv ~ÿuyz | yÿ à | y {ÿÞÿu |y ÿßÿÀjiÙnráºqsÿâÿÀjiÙsnrn¹j¾s hijklmnÿÀriir¾nãÁÿv zÿÅ zz { ÿ| } z {| ÿ {ÿ{ | ÿ z ~ {Ûÿ y yÿ | ÿ yzy ä ~ÿ ÿ | yÿ{ ÿnqººÿlsÿrájlnÿrÿºjÔqiÿ½i¹mqå

»½j¾sjiqkÿ½ijklmnsÿiqºrnqkÿnjÿn¼¹sÿ¹nqÒÿÃä {ê ÿ{ | åÆ

P ¡Y]]ÿ« YP]VWXXÿ« WWV ìU¡¡W ^PYVÿíP ^TW]ÿë Wd îÿSU §ÿ Y VWÿ¦® ïY^§XdVYXTÿ ÿfa¯ÿQ¨¨¨ ÿ£\£ èageé̈éÿ

P ¡Y]]ÿª«¬ÿ« YP]VWXX « WWVÿìU¡¡W ^PYVÿíP ^TW] ë WdÿîÿSU §ÿ Y VWÿ¦®b ìYX W Xÿ́STWW¨¨¨ ÿ£b[ èg\\ç̈éÿ

ëY`Wÿ£ÿU¢ÿç\

P ¡Y]]ÿª«¬ÿ« YP]VWXX « WWVÿìU¡¡W ^PYVÿíP ^TW] ë WdÿîÿSU §ÿ Y VW ¦®ïY^§XdVYXTÿëV X¨¨¨ ÿ[[ èaçbé̈é

ðU YVÿ U ¡W ìU¡¡W ^PYVÿ« YP]VWXXÿ« WWV SP TÿbÿìYX W ÿSTWWVX SU §ÿ Y VW¥ÿbe¯ÿ_ÿQÿa¨¨¨ ÿag è£féé̈é

ÑlsnjÒqiÿælqsn¹j¾sÿâÿr¾sÔqis

c Y« WWVÿSU « YP]VWXXÿ« WWV g\¯ÿQÿ£e¯ÿQÿgb¯ SP TÿbÿìYX W ÿ ÿ è£\éëfÿ

7 ÿ- %9 #

ñ yÿ ÿà y {| åÿuy z ÿ} zÿ Åyz òlqsn¹j¾Á Å {ÿ yÿ { | y ÿ {yy ÿ| ÿ|{ Ìÿ ǾsÔqiÁ ó ê{ÿ ÿ{ | ÿ z ~ {ôÿÝ{ÿ| ÿ z ÿ ~yÿ ~ÿÅ| ÿ zz| yÿÅ|{ ÿ~ yôÿõ ê yÿ yy ÿÅ z y~ôÿ {y óy ÿÊ y ÿöÿ {ÿÌËÛÿÕËÌ÷ ÿuyyÿ zyÿ Åyz ÿÃÖÆ òlqsn¹j¾Á ä {ÿ zyÿ{ yÿ~| y | ÿ }ÿ{ yÿ yÿà Æÿ|{ÿ| ÿ | y~ÿ| ÿå

11&&& 989 81 1'45.$3/07/11 2+32 04 5' 6+70! 230674897:6605! 24! -;2 <; <; =; ; >- 9 , (%, (% -

316


TRUE FOOD SERVICE EQUIPMENT, INC. 2001 East Terra Lane • O’Fallon, Missouri 63366 (636)240-2400 • Fax (636)272-2408 • (800)325-6152 • Intl Fax# (001)636-272-7546 Parts Dept. (800)424-TRUE • Parts Dept. Fax# (636)272-9471 • www.truemfg.com Model:

GDM-26

AIA #

Project Name: Location: Item #:

SIS #

Qty:

Model #:

Glass Door Merchandiser: Swing Door Refrigerator

GDM-26 The world’s #1 manufacturer of glass door merchandisers.

Oversized, factory balanced,

refrigeration system holds 33°F to 38°F (.5°C to 3.3°C).

Exterior - non-peel or chip white laminated vinyl; durable and permanent.

Interior - attractive, NSF approved,

white aluminum interior liner with 300 series stainless steel floor.

Self closing door. Positive seal, torsion type closure system.

“Low-E”, double pane thermal

insulated glass door assembly(ies) with extruded aluminum frame(s). The latest in energy efficient technology.

Patented integrated door light (IDL) system for brighter, shadow free illumination.

Entire cabinet structure is foamedin-place using Ecomate. A high density, polyurethane insulation that has zero ozone depletion potential (ODP) and zero global warming potential (GWP).

Bottom mounted units feature

”No stoop” lower shelf to maximize product visibility.

Storage on top of cabinet. Easily accessible condenser coil for cleaning.

Rough-In Data

Specifications subject to change without notice. Chart dimensions rounded up to the nearest 1/8" (millimeters rounded up to next whole number).

Cabinet Dimensions (inches) (mm) Model

GDM-26

Doors

Shelves

1

4

L

D†

30

297/8

762

759

H

HP

785/8

1/3

1998

Approvals:

MADE IN

U.S.A. SINCE 1945

3/11

Printed in U.S.A.

115/60/1

230-240/50/1

7.2 4.0

5-15P ▲

9

2.74

Crated Weight (lbs.) (kg)

325 148

▲Plug type varies by country.

† Depth does not include 11/8" (29 mm) for door handle.

TRUE REFRIGERATION®

1/3

Voltage

Cord Length NEMA (total ft.) Amps Config. (total m)

Available At:


Model:

Glass Door Merchandiser:

GDM-26

Swing Door Refrigerator

STANDARD FEATURES DESIGN • True’s commitment to using the highest quality materials and oversized refrigeration systems provides the user with colder product temperatures, and lower utility costs in an attractive merchandiser that brilliantly displays packaged food and beverages. REFRIGERATION SYSTEM • Factory engineered, self-contained, capillary tube system using environmentally friendly (CFC free) 134A refrigerant. • Extra large evaporator coil balanced with higher horsepower compressor and large condenser; maintains cabinet temperatures of 33°F to 38°F (.5°C to 3.3°C). • Sealed, cast iron, self-lubricating evaporator fan motor(s) and larger fan blades give True merchandisers a more efficient low velocity, high volume airflow design. This unique design ensures faster temperature pull down of warm product, colder holding temperatures and faster recovery in high use situations. • Bottom mounted condensing unit positioned for easy maintenance. “No stoop” lower shelf maximizes visibility by raising merchandised product to higher level. CABINET CONSTRUCTION • Exterior - non-peel or chip white laminated vinyl; durable and permanent. • Interior - attractive, NSF approved, white aluminum liner with 300 series stainless steel floor. • Insulation - entire cabinet structure is foamedin-place using Ecomate. A high density, polyurethane insulation that has zero ozone depletion potential (ODP) and zero global warming potential (GWP).

• Welded, heavy duty steel frame rail, black powder coated for corrosion protection. • Frame rail fitted with leg levelers. • Illuminated exterior sign panel. Variety of sign

• Listed under NSF-7 for the storage and/or

options available. DOOR • “Low-E”, double pane thermal insulated glass door assembly(ies) with extruded aluminum frame(s). The latest in energy efficient technology. • Door fitted with 12” (305 mm) long extruded handle. • Self closing door. Positive seal, torsion type closure system. • Magnetic door gasket of one piece construction, removable without tools for ease of cleaning. SHELVING • Four (4) adjustable, heavy duty PVC coated wire shelves 25 11⁄16”L x 23 ¼”D (653 mm x 591 mm). Four (4) chrome plated shelf clips included per shelf. • Shelf support pilasters made of same material as cabinet interior; shelves are adjustable on ½” (13 mm) increments. LIGHTING • Safety shielded fluorescent interior lighting. Door(s) utilize(s) full-length, patented, integrated doors light (IDL) system. • Cabinet lighting utilizes electronic ballast and T-8 bulbs for brighter illumination, longer bulb life and increased energy efficiency. MODEL FEATURES • Evaporator is epoxy coated to eliminate the potential of corrosion. • See our website www.truemfg.com for latest color and sign offerings. • Convenient clean-out drain built in cabinet floor.

display of packaged or bottled product. ELECTRICAL • Unit completely pre-wired at factory and ready for final connection to a 115/60/1 phase, 15 amp dedicated outlet. Cord and plug set included.

OPTIONAL FEATURES/ACCESSORIES Upcharge and lead times may apply. ❑ 230 - 240V / 50 Hz. ❑ Black exterior. ❑ Rosewood exterior. ❑ Stainless steel exterior. ❑ Black aluminum interior liner with black shelving. ❑ Stainless steel interior liner. ❑ 6” (153 mm) standard legs. ❑ 6” (153 mm) seismic/flanged legs. ❑ 2 ½” (64 mm) diameter castors. ❑ 4” (102 mm) diameter castors. ❑ LED Lighting. ❑ Red wine thermostat. ❑ White wine thermostat. ❑ Chocolate thermostat. ❑ Barrel lock (factory installed). ❑ Additional shelves. ❑ TrueFlex/TrueTrac gravity feed organizers. ❑ Pricing strips. ❑ Remote cabinets (condensing unit supplied by others; system comes standard with 404A expansion valve and requires R404A refrigerant). Consult factory technical service department for BTU information. All remote units must be hard wired during installation.

PLAN VIEW

WARRANTY One year warranty on all parts and labor and an additional 4 year warranty on compressor. (U.S.A. only)

METRIC DIMENSIONS ROUNDED UP TO THE NEAREST WHOLE MILLIMETER SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

KCL

Model

Elevation

Right

Plan

3D

GDM-26

TFAY09E

TFAY09S

TFAY09P

TFAY093

Back

TRUE FOOD SERVICE EQUIPMENT 2001 East Terra Lane • O’Fallon, Missouri 63366 • (636)240-2400 • Fax (636)272-2408 • (800)325-6152 • Intl. Fax# (001)636-272-7546 • www.truemfg.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.