JOEL BARNES
ARCHITECTURAL PORTFOLIO 2020
Examples of work from Frank Whittle Partnership
Proposals for a multi-usage leisure and retail development
Render of a sustainably sourced, open air night market
Proposal for a new hospital cafe on a psychiatric ward
Interior remodelling of a Golf Club players lounge
Proposed visuals for the Huddersfield Town FC training facility
Examples of work whilst under freelance employment at Parkinsoninc. Artistic impression of the Wirral Waters Development
Visualisation of a residential extension
Examples of work from Liberata Architects
Proposed visuals to restore and modernise a former civic building in Nelson
A stripped back option of the previous scheme
Construction plans of a residential remodelling to fulfil Part M compliance.
Proposed internals for grade II listed Mill and factory regeneration project
STUD UNLESS OTHERWISE SHOWN..
A1
13
11015 385
4976
1790
685
339
1328
1598
MJ
1115
ED-03
MJ
ESCAPE WINDOW WF-08
RWP
RWP
339
339
PV
DW
100
WC
MJ
1.5 m²
INDICATES MOVEMENT JOINT LOCATION, TO BE DISCRETELY LOCATED BEHIND RAIN WATER PIPES, WHERE POSSIBLE, AND IN ACCORDANCE WITH STRUCTURAL ENGINEER'S DETAILS AND SPECIFICATIONS.
WM
DW
339
339
SVP
RWP
PV
WG-03
MOISTURE RESISTANT SPOTLIGHTS INCLUDED TO KITCHEN AND BATHROOM SPACES. ALL OTHER ROOMS TO HAVE CENTRAL PENDANT LIGHTING FIXTURE. RWP PV WG-06 ELECTRICAL LAYOUT IS SUBJECT TO DETAILED DEISGN BY A SPECIALIST AND TO BE IN ACCORDANCE WITH PEARL DEVELOPMENT AND TOGETHER HOUSING DETAILED SPECIFICATION, IN ADDITION TO BUILDING REGULATIONS. ELECTRICAL LAYOUT TO BE DISCUSSED WITH ARCHITECT PRIOR TO FINAL ISSUE.
RWP
MJ 2148
664
339
1360
1228
4977
2148
664
1360
440 10328
ALL ASPECTS OF TIMBER FRAME SUBJECT TO DETAILED DESIGN BY SPECIALIST. ALL DIMENSIONS GIVEN ARE TO TIMBER STUD UNLESS OTHERWISE SHOWN..
385
2665
4976
4737
3941
ID-13
4
10.7 m² 2735
1280
WRDB
Rev Description / By / Chk'd / App'd
WRDB
STORE 0.9 m²
100
Client
PEARL Developments ID-114
2141
100
BEDROOM 1 10.7 m²
2735
OUTLINE OF CUPBOARD DOOR BEHIND.
BATHROOM 4.1 m²
Project
Further Clough Head, Nelson
SVP
22mm T&G CHIPBOARD ON, WF-01 241mm JOISTS WITH, 15mm PLASTERBOARD MECHANICALLY SKIMMED AND FINISHED
BATHROOM WF-02
WF-03
WF-04
RWP
1360
440 10328
339
685
1228
STORE
MJ
HAZ-6 - Hoarding FIXEDis TO UNDERSIDE, TO BE - Contractor to ensure secure adequate hoarding erected prior to work commencing.
1565
Date
Purpose of Issue
CONSTRUCTION
HAZ-5 - Pedestrians around the site - Contractor to ensure secure adequate hoarding is erected to prevent public access to site. - Contractor to ensure adequate signageINTERMEDIATE where pedestrian routes are to be redirected. FLOOR TO BE;
339
8990
100
8312
1355
ID-115
BOILER
3
BEDROOM 1
100
5
BATHROOM
MJ
1360
SVP BOXING FORMED FROM 4977TIMBER BATTENS AND FINISHED WITH TILES TO TO EXTEND INTO WINDOW REVEAL TO FORM SILL
HAZ-13 - Fire Prevention - Contractor to carry out a site fire risk assessment construction/manufacture MATCHbefore BATHROOM. TILEDofTOP timber frame and ensure sheathing board specification is suitable.
2128 385
685
1227 4976
Drawing
Construction Plans- House Type A-01-A
339
11015
900
13
1030
SD
6
STORE
RWP
11015
100
7
HAZ-4 - Nuisance to adjacent buildings Contractor to provide adequate protection is to be provided. 4.1 m² eg: dust and noise FULLY TILED, CEILING- HEIGHT BOXING ENCLOSING SVP AT HEAD OF THE BATH, HALF HEIGHT FULLY TILED BOXING TO WINDOW LEDGE HEIGHT FOR SVP REMAINING OF THE WALL.
06
1024
8
WRDB
RAFTERS
ID-14 NOTE: 2142 100 None of the measures specified below overrule the requirement for the Contractor to comply with all relevant health and safety legislation and good practice. The Contractor should always use the best available techniques, tools and equipment, including the quality of protective clothing, helmets, masks, goggles, ear defenders etc.
05
100
9
1280
638
100
WRDB
ID-113
638
1355
To be read in conjunction with all other consultants information
04
ID-112
ID-12
100
2515
applicable. BOILER TO MECHANICAL 4 ENGINEER'S DETAIL AND 1012 100 SPECIFICATION. VENTED TO It is assumed that all works on this drawing3 will be carried out by a competent FRESH AIR. contractor, FIT WEATHERTIGHT working where appropriate to an approved method statement. SEAL AT THE PASSAGE THROUGH THE EXTERNAL FABRIC. HAZARD IDENTIFICATION LIST 1.0 m²
MJ
665
100
100
MECHANICALLY OPERATED EXTRACTOR FAN TO GIVE A MINIMUM OF 3 AIR CHANGES PER HOUR AND ACTIVATED BY THE LIGHT SWITCH. TO BE DUCTED THROUGH TO EXTERNAL AIR. FIT WEATHER PROOF SEAL AT PASSAGE THROUGH EXTERNAL FABRIC OF BUILDING. DUCT TO BE WRAPPED IN MINERAL WOOL OR SIMILAR INSULATION TO PREVENT BUILD UP OF CONDENSATION WITHIN DUCTING. MINIMUM 20 MINUTE OVERRUN. EXTRACT VENTILATION RATES IN ACCORDANCE WITH BUILDING REGULATIONS APPROVED DOCUMENT F: KITCHEN 30l/s BATHROOM 15l/s WC / ENSUITE 6l/s 1481 100 30l/s 2347 UTILITY
SD
8312
8990
8312
FF
COLD ROOF
3583
947
FITTED ABOVE AND BETWEEN Refer to the relevant Construction (Design and Management) documentation where
2826
WALL MOUNTED EXTRACT FAN
ID-111
339
WM
SVP
HD
100
5
TIMBER FRAME TO SPECIALIST DESIGN
13
4.1 m²
SAFETY, HEALTH AND ENVIRONMENTAL INFORMATION 350mm TOTAL MINERAL WOOL INSULATION
CEILING MOUNTED EXTRACT FAN
Residual Risk 1 - Maintenance and cleaning of first floor windows and gutter will require a telescopic pole
9.6 m²
3645
100
2350
R01
1200
100mm PVC SOIL AND VENT PIPE BOXED IN TO THE CORNER OF THE WC AND TO RUN UP TO THE BATHROOM OVER. SVP TO BE VENTED THROUGH ROOF TO FRESH AIR. PIPE TO VENT A MINIMUM 1000mm ABOVE ANY OPENING WINDOW AND TO BE FITTED WITH A BIRD GUARD TO TOP. ALLOW FOR A WEATHERTIGHT SEAL AT THE PASSAGE THROUGH THE EXTERNAL FABRIC OF THE BUILDING.
100
1608
1608
1.5 m²
1509
NOTE: None of the measures specified below overrule the requirement for the Contractor or Client to comply with all relevant health and safety legislation and good practice. The Clien should always use the best available techniques, tools and equipment, including the qualit of protective clothing, helmets, masks, goggles, ear defenders etc.
RWP
BEDROOM 2
LANDING
3645
1037
1
100
100
WC
2
1808
918
ID-001
100 INDICATIVE KITCHEN LAYOUT, SUBJECT TO DETAILED DESIGN BY KITCHEN MANUFACTURER, TO BE APPROVED BY THE CLIENT.
SD
1
RESIDUAL RISKS LIST
MJ
2451
6.5 m²
10
SD
100
100
HAZ-14 - Lockable Loft Hatches - Contractor to ensure that lofts are lockable but always openable from the loft level.
11
ID-15
ID-004
913
9
1012indicated 100below and 1030 This original document is issued for the purpose contains100 information of confidential nature. Further 8copies and circulation will be strictly in accordance with the confidentiality agreement under the contract. This original must be 7 destroyed or returned to the contractor. 6
3
FF
UP 2
69
BEDROOM 3
12
Responsibility for the reproduction of this drawing in paperDN form, or if issued in electronic LANDING format, lies with the recipient to check that all information has been replicated in full and m² is correct when compared to the original paper or electronic image. 4.1 Graphical 11 representations of equipment on this drawing have been co-ordinated, but are approximations only. Please refer to the Specifications and / or Details for actual sizes 10 and / or specific contractor construction information.
920
4
3214
12
2457 12 with the latest All works are to be carried out in accordance British Standards and Codes 13 of Practice unless specifically directed otherwise in the specification.
BOILER
7.5 m²
9.6 m²
Discrepancies and / or ambiguities within this drawing, between it and information given elsewhere, must be reported immediately to the architect for clarification before proceeding. ID-11
100
HALL
5
All other design team elements, where indicated, have been imported from the consultant's drawings and reference should be made to the individual consultant's drawings for exact setting out, size and type of component.
8990
100
13.0 m²
3005
3205
HD
100
2456
BEDROOM 2
6.5 m² DO NOT SCALE this drawing (printed or electronic versions). Contractors must check all dimensions from site. ROOF TRUSS DESIGN BY A SPECIALIST
1913
1038
2420
This drawing is copyright and owned by Liberata Ltd, and is for use on this site only unless contractually stated otherwise. BEDROOM 3
100
1011
3
KITCHEN / DINING ROOM
7 6
3005
6.0 m²
5
890
0° 35.0
HALL
6
HEAT DETECTOR TO BE MAINS OPERATED SELF CONTAINED UNIT WITH RECHARGEABLE BATTERY BACK UP INSTALLED IN ACCORDANCE WITH BS 5839-6 2004 - GRADE D - CATEGORY LD3 STANDARD. ALL ALARMS TO BE INTERCONNECTED. FITTINGS TO BE CEILING MOUNTED AND INSTALLED MINIMUM 300mm FROM ANY WALL OR LIGHT FITTING. TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS DETAILS AND SPECIFICATIONS.
1.4 m²
8
13.0 m²
4
HD
ST
9
KITCHEN / DINING ROOM
7
RECESSED GAS AND ELECTRIC METER BOXES. ALLOW FOR ISOLATOR SWITCH FOR THE ELECTRICITY SUPPLY.
SMOKE DETECTOR TO BE MAINS OPERATED SELF CONTAINED UNIT WITH RECHARGEABLE BATTERY BACK UP INSTALLED IN ACCORDANCE WITH BS 5839-6 2004 - GRADE D CATEGORY LD3 STANDARD. ALL ALARMS TO BE INTERCONNECTED. FITTINGS TO BE CEILING MOUNTED AND INSTALLED MINIMUM 300mm FROM ANY WALL OR LIGHT FITTING. TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS DETAILS AND SPECIFICATIONS.
1808
ST
10
1.4 m²
8
3205
13
100
100
8312
8990
SD
11
ID-002
11
9
100
2515
3300
OR 500mm2/m2 OF FLOOR AREA, WHICHEVER IS THE GREATER. AIR BRICK TO EXTERNAL WALL TO BE SPECIFIED TO MATCH THE WALL.
100
12
13
10
1360
ESCAPE WINDOW WF-05
100
3300
PV
3300
3300
16.4 m² TO ACHIEVE AN TOTAL OPENING OF NOT LESS THAN 1500mm2/m RUN OF EXTERNAL WALL
CLOSE EXTERNAL CAVITY AT EITHER END OF THE PARTY WALL WITH ISOVER CAVITY WALL BARRIER 300mm WIDE, IN ACCORDANCE WITH ROBUST DETAIL E-WT-3.
ID-003
14
339
1565
ESCAPE WINDOW WF-06
920
LIVING ROOM INDICATIVE LOCATION OF PERISCOPIC UNDERFLOOR VENTILATORS ON OPPOSING WALLS.
16.4 m²
339
LIVING ROOM
12
685
4976
2665
385
4976
1790
ESCAPE WINDOW WF-07
2457 4977
385 1360
339
WG-07
RWP
11015 4977
1565
339
ED-04
PV
685
To be read in conjunction with all other consultants information
MJ WG-08
VENTILATED RIDGE TILE
339
32810 552
100
1598
1913
1328
4737
685
100
1115
3583
4977
3941
339
HAZ-13 - Fire Prevention - Contractor to carry out a site fire risk assessment before construction/manufacture of timber frame and ensure sheathing board specification is suitable.
685
2457
100
1360
2420
BEDROOM 3
2665
ESCAPE WINDOW WF-06
9.6 m²
69
4737
3941 WRDB
9
1280 WRDB
MJ
100
ID-112
1355
100
WRDB
1280 WRDB
10.7 m² 2735
SVP
ID-115 ID-114
100
BEDROOM 1 10.7 m²
2735
BATHROOM 4.1 m²
Project
Further Clough Head, Nelson WF-03
WF-04
RWP
FOUNDATIONS TO STRUCTURAL ENGINEER'S DESIGN AND SPECIFICATION
1360
440 10328
MJ
10328 1565
339 339
685
1228 4977
1360
2128 385 11015
www.liberata.com
685
1227 4976
339
Drawing
A standard house type construction package for a council funded development in East Lancashire
SECTION
Construction Plans- House Type A-01-A 1 : 2 0
Scale @ A1
Drawn
Checked
Approved
class number
revis
Registered office: Liberata UK Limited, 1st Floor, 100 Wood Street, London EC2V 7AN (Registered in England and Wales - No 1238274).
ST
0
ACODRAIN, OR SIMILAR, INSTALLED AT LEVEL THRESHOLD IN ACCORDANCE WITH MANUFACTURER'S DETAILS AND SPECIFICATION.
type
No. 1 Market Street, Nelson, BB97LJ T +44 (0) 1282 878787 F +44 (0) 1282 878993
125mm RIGID INSULATION ON, 2000 GAUGE DPM BEAM AND BLOCK FLOOR (SUBJECT TO
339 WF-02
5m
GROUND FLOOR CONSTRUCTION TO BE;
Client
SVP
WF-01
4
75MM SCREED ON, Date Rev Description / By / Chk'd / App'd Purpose of Issue
ID-113
100 920 1913
4.1 m²
MJ
3
PEARL Developments
2141
BATHROOM
1913
0.9 m²
100
BEDROOM 1
STORE
3645
100
3583
ID-14
3645
1.0 m²
RWP
2
CONSTRUCTION DETAILED DESIGN BY A SPECIALIST) Ground Floor
339
339 RWP
3
BOILER
100
STORE
2142
FULLY TILED, CEILING HEIGHT BOXING ENCLOSING SVP AT HEAD OF THE BATH, HALF HEIGHT FULLY TILED BOXING TO WINDOW LEDGE HEIGHT FOR REMAINING OF THE WALL.
4
ID-13
1012
1
HALL
5
100
920
BOILER
3
1030
zone
OUTLINE CUPBOA
0
SD
6
ID-15
100
4
100
7
5
BOILER TO MECHANICAL ENGINEER'S DETAIL AND SPECIFICATION. VENTED TO FRESH AIR. FIT WEATHERTIGHT SEAL AT THE PASSAGE THROUGH THE EXTERNAL FABRIC.
1024
8
31/05/20
origin building level
A1837-LIB-A01-XX-XX-AL 20-101
TIMBER STAIRCASE TO HAVE A CONSISTENT RISE OF 205mm AND GOINGS OF 230mm WITH THE EXCEPTION OF THE WINDERS. HANDRAIL TO BE POSITIONED ON BOTH SIDES OF STAIR AT 900mm 1000mm ABOVE PITCH LINE OF THE STAIR. STAIRCASE AND BALUSTRADES SUBJECT TO DETAILED DESIGN BY SPECIALIST
100
6
100
100
SD
7
1355
638
100
2515
1030
project
TIMBER FRAME TO SPECIALIST DESIGN
100
10
100 100
8
638
2515
8312
8990
8990
8312
4.1 m²
Date
Drawing Identifier
5° 41.8
1012
1:50
Approved
WPS WPS
A18-37
11
10 9
LANDING
Checked
JB
Project No.
13
ID-12
LANDING
Drawn
1 : 50
Residual Risk 1 - Maintenance and cleaning of first floor windows and gutters will require a telescopic pole
ID-111
12
4.1 m²
11
100
12
13
DN
Scale @ A1
FIRST FLOOR GA PLAN
RWP
9.6 m²
6.5 m²
SHOWN ARE INDICATIVE ONLY, AND ARE SUBJECT TO DETAILED DESIGN BY STRUCTURAL ENGINEER
NOTE: None of the measures specified below overrule the requirement for the Contractor or Client to comply with all relevant health and safety legislation and good practice. The Client should always use the best available techniques, tools and equipment, including the quality of protective clothing, helmets, masks, goggles, ear defenders etc.
R01
4737 100
ID-11
2457
12
Floor
To be read in conjunction 2678with all other consultants information
MJ
2451
BEDROOM 3
HAZ-14 - Lockable Loft Hatches TIMBER FRAME WALL TIE LOCATIONS - Contractor to ensure that lofts are lockable but always openable from the loft level.
RESIDUAL RISKS First LIST
BEDROOM 2
3941
6.5 m²
890
ESCAPE WINDOW WF-05
2456
BEDROOM 2
14
339
1565
339
1:50
ESCAPE WINDOW WF-07
2665
339
339
4976
1790
GROUND FLOOR GA PLAN ESCAPE WINDOW WF-08
RWP
WP
1360
225 min.
MJ
385
1565
8990
685
8312
1115
3583
552
4977
2000
339
1700
11015 339
VENTILATED VOID
DO NOT SCALE this drawing (printed or electr all dimensions from site.
All other design team elements, where indicate consultant's drawings and reference should be drawings for exact setting out, size and type of
Discrepancies and / or ambiguities within this d elsewhere, must be reported immediately to the proceeding.
All works are to be carried out in accordance w of Practice unless specifically directed otherwis
Responsibility for the reproduction of this draw format, lies with the recipient to check that all in is correct when compared to the original paper representations of equipment on this drawing h approximations only. Please refer to the Specif and / or specific contractor construction inform
VENTED RIDGE TILE TO MATCH ROOF TILES
This original document is issued for the purpos information of confidential nature. Further copie accordance with the confidentiality agreement destroyed or returned to the contractor.
SAFETY, HEALTH AND ENVIRONM
SLATE EFFECT ROOF TILES
Refer to the relevant Construction (Design and applicable.
It is assumed that all works on this drawing will contractor, working where appropriate to an ap
0° 35.0
WF-02
BLACK UPVC GUTTERS AND RAINWATER PIPES
*
WF-03
1200
1050
*
WF-01
GREY UPVC WINDOW FRAMES. WINDOWS TO BE ARGON FILLED WITH A MINIMUM U VALUE OF 1.4W/m2K
WF-04
1500
BUFF BRICK FACADE
First Floor 2678
First Floor 2678
ED-01
*
WG-02
WG-03
*
ED-02
WG-04
*
WG-05
WG-06
Ground Floor 0
ELEC METER
COMPOSITE FRONT DOOR, COLOUR TO BE VARIED ACROSS SITE, TO BE DETERMINED. MINIMUM U VALUE OF 1.4W/m2K.
1200
WG-01
1050
*
3750
FLAT ROOF CANOPY
2no. COURSES OF BLUE ENGINEERING BRICK BELOW DPC
RWP MJ
RWP MJ
FIT NEW RECESSED GAS AND ELECTRIC METER BOXES IN POSITION AS SHOWN. ALLOW FOR ISOLATOR SWITCH FOR THE ELECTRICITY SUPPLY POSITION TO BE CONFIRMED
GAS METER
Ground Floor 0 Ground level indicative only; for detailed design of plot levels, refer to Structural Engineer's design and specification.
Ground level indicative only; for detailed design of plot levels, refer to Structural Engineer's design and specification.
FRONT ELEVATION
SIDE ELEVATION
1:50
1:50
Rev Description / By / Chk'd / App' Purpose of Issue
CONSTRUCTION Client
PEARL Developm
First Floor 2678
WG-07
1200
MEANS OF ESCAPE WINDOW.
ED-04
WG-08
First Floor 2678
Drawing
Construction Eleva Type A-01-A ELEC METER
2100
ED-03
Further Clough He
1500
MEANS OF ESCAPE WINDOW.
WF-08
1200
MEANS OF ESCAPE WINDOW.
WF-07
1500
MEANS OF ESCAPE WINDOW.
WF-06
1200
Project WF-05
GAS METER
Scale @ A1
1 : 50
900
Ground Floor 0
RWP MJ
RWP
Ground Floor 0
Drawn
JB
Project No.
A18-37
Ground level indicative only; for detailed design of plot levels, refer to Structural Engineer's design and specification.
Ground level indicative only; for detailed design of plot levels, refer to Structural Engineer's design and specification.
Drawing Identifier project
REAR ELEVATION
SIDE ELEVATION
1:50
1:50
origin building level
zone
ty
A1837-LIB-A01-XX-XX
0
1
2
3
4
5m
No. 1 Market Street, Nelson, BB97L T +44 (0) 1282 878787 F +44 (0) 1 www.liberata.com
Registered office: Liberata UK Limited, 1st Floo (Registered in England and Wales - No 12382
long elevation