Am series screwing manager insturction manual 2014 07 17

Page 1

Serial No.:ˍˍˍˍˍˍ ASA- The Operation Manual of AM Digitalized Management System for Screw Fastening

○ Special Thanks to our customer Thank you for choosing ASA light and powerful electric screwdriver and AM Digitalized Management System for Screw Fastening (AM controller). To ensure the tool fully utilizes its maximum performance and extend its life, please read this manual before use.

○Feature 

The alarm informs the operator any omission, incomplete fastening, and thread damage during the operation.

The counting function helps you count up to max. 60K units and max. 99 pieces of screws which need to be fastened in each work piece. This can be set up manually according to your preference.

The attached output terminal can be connected to an external controller for single control purpose.

Universal power source: It is suitable for any power source ranges between 100-240VAC, 50/60Hz.

Stepless control: output stepless control and constant voltage makes the assembly of light, thin, short, and small works more efficient and they are key features electron industry pursues after. The smaller the screw, the higher locking and tightening is required. With this function, the requirements of high precision and low inertia in both long and short screws fastening can be met.

○Specification MODEL NO.

AM-30

AM-45

AM Controller AM-55

AM-65

AM-85

ITEM Counting Range of Accumulative Screwing for work pieces Range of Set Number of Screwing for a single work piece Setting Range of Number of Sample Screwing Time Range of Number of Memory/Calling-out of setting

1-60000 1~99 1~99 10 / 10 set 0.01~9.99 seconds

Range of Sampling Screwing Time Setting Range of Screwing Time Error Judgment Signal Output Mode Input Voltage (VAC) Output Voltage (VDC) Output Voltage Setting Output Pin Internal signal output External signal input No. of Screwdriver per screwing manager Power(W)

Applicable Model

Dimension Weight AC cable length (m)

± 1~99 % OK sound and green LED light on/NG sound and red LED light on Dry Contact (no voltage contact signal) 100~240 V 20 ~ 30 V 25 ~ 35 V 9 ~ 15 V 20 ~ 30 V 20 ~ 30 V 5P

Stepless Control 5P 5P 5P 6P Switch signal/Shut off signal/ OK fastening signal/NG fastening signal Switch signal 1 pc

75 W BS-2000 BS-3000

70 W ASA-2000/S ASA-3000/S

BS-4000 BS-4000F BS-6000 BS-6500 BS-6800

ASA-4000/S ASA-4500/S

37.5 W ASA -S1000M ASA-S2000M ASA-S2500M

75 W ASA-S1000M ASA-S2000M ASA-S2500M ASA -2000M/S ASA-3000M/S ASA-4000M/S ASA-5600M ASA-7000/S ASA-8000/S

176 x 84 x 61 mm 0.45 kg 1.8 M

75 W ASA -6000 ASA-6500 ASA-6800 ASA-7500 ASA-8500