ABBREVIATIONS
3'-0" Min 1'-6" 1'-6"
1. General: all work to be completed in accordance with the new york city building code, article 19, and regulations of all other agenies having jurisdiction. 2. Means of egress: all existing means of egress for tenants of the building to be maintained clear and free of all obstructions, such as building materials, tools, etc. 3. Fire safety: a. All building materials which are stored at the site or any area of the building are to be stored in a locked area. access to the area to be controlled by the owner, or the general contractor. b. All materials to be stored in a orderly fashion. c. All flammable materials to be kept tightly sealed in their respective manutacturers' containers. such materials are to be kept away from heat. d. All flammable materials to be used and stored in an adequately ventilated space. e. All electrical power to be shut off where there are exposed conduits. f. All electrical power in the construction area to be shut off after working hours. g. Contractor, at all times, to ensure there is no natural gas leakage in the buildings, or any flammable gas to be used during construction. 4. Dust control: a. Debris, dirt and dust to be kept to a minimum and confined to the immediate constuction area. b. Contractor to isolate construction area from occupied building area by means of temporary partitions or heavy weight drop cloths. c. Debris, dirt, and dust to be cleaned up and cleared from the building site periodically to avoid excessive accumulation. 5. Noise after hours: a. Construction operations will be confined to normal working hours, as stipulated in the alteration agreement. b. Contractor must obtain written permission from all affected parties to work other than regular hours. 6. Construction operations will not involve interruption of heating, water, or electrical services to other tenants. 7. Construction work will be confined to the apartment interior, and will not create dust, dirt, or other such inconveniences to the other apartment units within the building.
ZONING ANALYSIS
3'-0" Min 1'-6" 1'-6"
3'-6" Min
2'-6" Min
SIDE
SIDE
4'-8" Min
4'-8" Min
5'-6" Min
3'-0"
LAV Clear Floor Space
Clear Floor Space
BLOCK: LOT: ZONING MAP: ZONING DISTRICT:
Nava Companies
1546 7501 9A R8B
31 Union Square West, Suite 2D New York, NY 10003, USA Tel: 212.365.1052 www.navacompanies.com
Clear Floor Space
AREA CALCULATIONS 4'-0" Min
4'-0" Min
5'-0" Min
Mechanical Engineer:
5'-0" SHOWER SIZES AND CLEARANCES
CLEAR FLOOR SPACE FOR ADAPTABLE BATHROOMS
LOT AREA:
2043.4 SF N
RESIDENTIAL FLOOR AREA RATIO MAX F.A.R. MAX F.A.R.
Note: Cross hatched areas to receive blocking for securing grab bars
3.69 2043.4 x 3.69 = 7540.15 SF
3'-0" Max 1'-0"1'-0" Min Min
TP
STANDARD SYMBOLS
Structural Engineer:
INTERIOR ELEVATION 2/A00.01
19" Max 4'-0" Min
TOILET PAPER DISPENSER LOCATION
D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
APPROXIMATE BUILT SQUARE FOOTAGE:
(B) BACK WALL
(A) SIDE WALL
BLOCK: 1546 LOT: 7501 ZONING MAP: 9A ZONING DISTRICT: R8B
17" Min 2'-6" Min
1'-7" Min
RESIDENTIAL GROSS AREA
2'-8" Min 3'-2" Max
GENERAL NOTES:
CLEAR FLOOR SPACE AT LAVATORIES
REINFORCING AREAS FOR INSTALLATION OF GRAB BARS IN BATHROOMS
GROUND FLOOR (RESIDENTIAL UNIT 1): FIRST FLOOR (RESIDENTIAL UNIT 1): SECOND FLOOR (RESIDENTIAL UNIT 2): THIRD FLOOR (RESIDENTIAL UNIT 3):
1180 SF 1180 SF 800 SF 800 SF
TOTAL RESIDENTIAL FLOOR AREA:
3960 SF
Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
#
#
###
#
INTERIOR ELEVATION
Key Plan:
#
3
EXTERIOR ELEVATION
PROPOSED BUILDING ADDITION: X = 0"-25"
2'-1" Max
40" Max 29" Min 27" Min 9" Min
Y = 48"
2'-6"
Note: Dashed line indicates dimensional clearances of optional underlavatory enclosure
X 4'-0"
Z=X OR GREATER
GROUND FLOOR (RESIDENTIAL UNIT 1): FIRST FLOOR (RESIDENTIAL UNIT 1): SECOND FLOOR (RESIDENTIAL UNIT 2): THIRD FLOOR (RESIDENTIAL UNIT 2): FOURTH FLOOR (RESIDENTIAL UNIT 2):
1180 SF 1180 SF 800 SF 800 SF 800 SF
TOTAL RESIDENTIAL FLOOR AREA:
4760 SF
MAX ALLOWABLE RESIDENTIAL FLOOR AREA = 7540.15 SF > 4760 SF = OK
Note: X = Reach Distance, Y = Maximum Height, Z = Clear Knee Space. Z is the clear space below the obstruction, which shall be at least as deep as the reach distance
MAXIMUM FORWARD REACH OVER AN OBSTRUCTION
ROOMNAME
3
SPACE DESIGNATION
REVISION DESIGNATION
Legend:
WINDOW DESIGNATION
Notification:
LAVATORY CLEARANCES
DOOR
DOOR DESIGNATION
HEIGHT REQUIREMENTS
28" - 36"
DEMOLITION NOTES 1. Provide selective demolition work as shown and as needed for a complete and proper installation of the work. 2. Contractor to perform selective demolition in a systematic manner. Use such methods as required to complete work indicated in accordance with demolition schedule and governing regulations; comply with new york city building code and regulations of the building. 3. Remove all items necessary to accommodate the new construction. 4. Remove salvageable items as noted for reuse with care to prevent damage. Store in a protected area where directed by the owner. 5. Repair and restore all permanent materials damaged during the demolition process or other construction activity. 6. Remove debris, rubbish and other non-salvageable materials resulting from demolition operations from the site. 7. Demolish and remove all existing partitions, doors, walls, floor coverings and ceilings as noted and/or keyed. 8. Demolish and remove all plumbing lines, fixtures and equipment as noted and/or keyed. All branchwork plumbing to be removed back to the riser. 9. Demolish and remove all existng electrical, telephone and computer wiring, devices, conduits and black boxes back to existing panels as noted and/or keyed. 10. Demolish all soffits, dropped ceilings including pencil rod and chicago bar or other furring materials. 11. Demolish all electrical points, including jboxes, terminations, cabling and switch controls. 12. Demolish all recessed light fixtures, sconces, cabinetry lighting and track lighting. 13. Demolish all air conditoning equipment including condensor units, air handlers, controls, and all duct work and grills. 14. All gas branch work to be demolished back to riser. New shut off valves to be installed. 15. All water, waste and venting branch work to be demolished back to riser locations. New shutoff valves to be installed throughout.
SUGGESTED FLEXIBLE SUPPLY LINES
MIN. BASE HEIGHT MAX. BASE HEIGHT
SUGGESTED SLIP JOINT IN TAIL PIECE
REQUIRED
PROPOSED
55 FT 60 FT
55 FT
1
DRAWING LABEL Scale: SCALE: ACTUAL SIZE
COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
Issue Description
Date
ISSUE
MAX BLDG. HEIGHT
2'-6" Min BEFORE REMOVAL OF CABINETS AND BASE
75 FT
55 FT NO CHANGE OF USE, OCCUPANCY AND EGRESS
4'-0" Max
28" - 36" Max
CABINETS AND BASE REMOVED AND HEIGHT ALTERNATIVES
Date
Revision
SMOKE DETECTOR/CARBON MONOXIDE NOTES
2'-6" Min CABINETS AND BASE REMOVED AND HEIGHT ALTERNATIVES
BEFORE REMOVAL OF CABINETS AND BASE
LIST OF DRAWINGS
MEP AND STRUCTURAL DRAWINGS:
RINKER RESIDENCE 344 E 84TH STREET NEW YORK, NY 10028
LOCATION OF GRAB BAR REINFORCEMENTS AND CONTROLS OF ADAPTABLE SHOWERS
GENERAL NOTES Seal & Signature: 6" Max 2'-0"
Date: 5/26/2016 Project Number:
9" 5'-0" Max Min
Drawing: Checked:
6" Max
GENERAL NOTES GROUND & SECOND FLOOR DEMO PLAN THIRD & FORTH FLOOR DEMO PLAN FIRST & SECOND FLOOR CONSTRUCTION PLAN THIRD AND FORTH FLOOR CONSTRUCTION PLAN ROOF CONSTRUCTION PLAN AND WALL TYPES SECOND & THIRD FLOOR RCP & POWER PLAN FOURTH FLOOR AND ROOF RCP & POWER PLAN SCHEDULES SCHEDULES ELEVATION
Project Title:
Floor Number:
ARCHITECTURAL DRAWINGS: T-001.00 A-001.00 A-002.00 A-003.00 A-004.00 A-005.00 A-006.00 A-007.00 A-008.00 A-009.00 A-010.00
6" Min 32" Max
4'-0" Max
6" Min
2'-3" Max
32" Max
6" Min
Note: Shower head and control area may be on back wall or on either side
32" Max
1. Smoke/Carbon Monoxide detectors or devices shall be installed in ordinance with the Housing Maintenance Code, Multiple Dwelling Law the New York City Building Code the New York City Electrical Code and LL 7/04. 2. Smoke Detectors and Carbon Monoxide Detectors may be combined providing the devices comply with the provisions of title 27 of the administrative code of the city of New York and any applicable rules promulgated thereunder. 3. Each Smoke/Carbon Monoxide Detector shall be installed in accordance with Reference Standard 17-12 of the New York City Building Code. 4. Each Smoke/Carbon Monoxide Detector shall be installed outside of each sleeping room in the immediate vicinity or within 10-0" of the entrance to a sleeping room. 5. Each Smoke/Carbon Monoxide Detector shall be of a type that allows for readily testing of such device. 6. Duplex units shall have a device located on each level if only one means of egress is provided from each level. 7. Ceiling mounted devices shall be a minimum distance of 4" from any wall. 8. Wall mounted devices shall be a minimum of 4" to a maximum of 12" from the ceiling. 9. Each dwelling unit shall be equipped with an approved type smoke/carbon monoxide detector device receiving primary power from the building wiring with no switches in the circuit other than the over current device protecting the branch circuit as per New York City Building Code Sec. 27-980. 10. Existing buildings that are not equipped with hardwired connections shall be supplied with battery operated devices. 11. Such smoke/carbon monoxide detector must be either the ionization chamber type or the photoelectric detector type as per New York City Building Code Sec. 27-981, (b). 12. A "Certificate of Satisfactory Installation for Smoke/Carbon Monoxide Detectors" must be filed with the division of code enforcement H.P.D., 10 days after installation. 13. Written information of testing and maintenance of the devices shall be provided to the dwelling unit owner.
Drawing Number:
3'-2" 2'-8"
TR8: HVAC SERVICE WATER HEATING EQUIPMENT HVAC SERVICE WATER HEATING SYSTEMS DUCT AND PIPING INSULATION ELECTRICAL METERING LIGHTING AND DWELLING UNITS INTERIOR LIGHTING POWER LIGHTING CONTROLS
2'-3" Max
ZONING INFORMATION
4'-6" Min 1'-0" Max 3'-6" Min
1. The general conditions of the American Institute of Architects for the contract of the construction of interiors, latest edition, is hereby made a part of this contract as if they were printed herein in full. 2. The contractor shall provide owner with all applicable certificates of insurance, liability and workman's compensation as required by law and building regulations. 3. The contractor shall take all necessary precautions to protect the owner, tenants and job site from damage or fire. 4. The contractor shall inspect the job site to verify all conditions, measurements and job requirements and shall report any inconsistencies to the architect immediately. 5. The contractor shall furnish all labor, materials, equipment, and services required to perform a finished job and for the proper completion of all trades whether or not such items are expressly mentioned in the contract documents. 6. The contractor shall coordinate the work of all trades and cooperate with the the work of all trades whether or not part of this contract. 7. All work performed must comply with all current rules and regulations of all municipal agencies having jurisdiction over this work and with all department of building rules and the rules of the particular building in which the work is located. 8. The job site shall be kept broom clean at all times. upon completion of the work the contractor shall provide a broom clean space, free of all dust and debris. 9. The owner's signature must be obtained prior to ordering any materials or executing any work in excess of the original contract. 10. All work shall comply with current trade practices and conform to the standards of good workmanship. 11. The contractor shall cause the owner and architect and their agents to be held harmless from all liabilities resulting from any and all situations resulting from this work. 12. The contractor shall maintain a complete and up to date set of drawings on the job site at all times. 13. The contractor shall prepare and submit shop drawings to the architect for approval. Contractor shall inspect shop drawings prior to submission and no material shall be ordered prior to approval of shop drawings. 14. The contractor shall protect all property from damage. Any damage caused by the contractor's workmen or sub-contractor's workmen shall be repaired or replaced at no cost to the owner. 15. Contractor shall coordinate the work of all trades and shall cooperate with all trades not specifically part of this contract. 16. Contractor shall submit samples to the architect of all finishes of hardware, wood, switch plates, stone, tile, etc., for approval, prior to ordering. 17. Contractor shall be responsible for arranging with building management for elevators and/or other hoisting facilities for the handling of materials and shall bear all costs for same. 18. Tenant shall, through its building code consultant, arrange for drawings to be filed with the building department in the municipality having jurisdiction over the work, and for final sign-off. Contractor shall obtain permits and all other licenses and sign-offs required and shall bear all costs for same. 19. General contractor shall properly protect the owner and any adjacent property or work. Any damage to the same caused by contractor's workmen or subcontractor's workmen shall be repaired or replaced without delay. Patching and replacing of damaged work shall be done by general contractor. General contractor shall provide all necessary protection for the work until same is turned over to the client. 20. Shareholder is responsible for all elec. radiant heat 21. No solenoids or restrictions on the building HVAC/fan coil units. 22. All cabinetry to be removable
1'-6"
01
TR1: FIRE STOP/DRAFT STOP/FIRE BLOCK MECHANICAL VENTILATION FINAL ENERGY CODE COMPLIANCE
Architect:
TENANT SAFETY NOTES: RENOVATION IN RESIDENTIAL BUILDING:
Note: Cross hatched areas to receive blocking for securing grab bars
CONTROLLED INSPECTIONS
PLOT PLAN (NTS)
0.
AIR CONDITIONING ADJUSTABLE ABOVE FINISH FLOOR ALUMINUM AS NOTED ARCHITECT ACOUSTIC TILE CEILING BUILDING BY OTHERS BUILDING STANDARD CABINET CABINET CONTRACTOR CENTERLINE CLOSET CEILING COLUMN CONCRETE CONTINUOUS CARPET CERAMIC TILE DOWN DOOR DETAIL DRAWING ELEVATION ELECTRIC EQUAL EXISTING TO BE RELOCATED ELECTRIC WATER COOLER EXISTING FURNISH & INSTALL FINISH FULL HEIGHT FLOOR FINISH OPENING FIREPROOF FIREPROOF SELF CLOSING FIRE RATED FRAME FLUSH VALVE GAUGE GALVANIZED GENERAL CONTRACTOR GLASS GYPSUM WALL BOARD HOLLOW METAL HOLD OPEN HOUR HEIGHT HEATING/VENTILATION INSULATION INTERIOR INSTALL ONLY JANITOR CLOSET JUNCTION BOX JAMB OPENING JOINT LAVATORY LIGHTING MAXIMUM MINIMUM MECHANICAL MANUFACTURER MASONRY OPENING METAL NO HOLD OPENING NOT IN CONTRACT NUMBER NOT TO SCALE ON CENTER OPENING OPPOSITE PLATE PLASTIC LAMINATE PLUMBING PLYWOOD PANEL POLISHED PAIR PAINT QUARRY TILE RADIUS REFLECTED REINFORCE REQUIRED ROOM SEPARATE CIRCUIT SIMILAR STAINLESS STEEL SPECIFICATION SPEAKER SPRINKLER SQUARE STANDARD STEEL STRUCTURAL TELEPHONE TRIMMED OPENING TYPICAL UNLESS OTHERWISE NOTED VERIFY IN FIELD VINYL TILE WITH WOOD
THERE IS NO CHANGE OF USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION
A0
A/C ADJ AFF ALUM AN ARCH ATC BLDG BO BS CAB CABC CL CLOS CLG COL CONC CONT CPT CT DN DR DTL DWG EL ELEC EQ ER EWC EXTG F/I FIN FH FLR FO FP FPSC FR FRM FV GA GALV GC GL GWB HM HO HR HT HVAC INSUL INT I/O JAN CL JB JO JT LAV LTG MAX MIN MECH MRF MO MTL NHO NIC NO NTS OC OPNG OPP PL PLLA PLMB PLY PNL POL PR PT QT RAD REF REINF REQ'D RM SC SIM STNSTL SPEC SPKR SPR SQ STD STL STR TEL TO TYP UON VIF VT W/ WD
GENERAL NOTES
T-001.00 FOOT
BACK Note: Cross hatched areas to receive blocking for securing grab bars
LOCATION OF GRAB BAR REINFORCEMENTS AND CONTROLS OF ADAPTABLE BATHTUBS
HEAD
0440
Architect:
GENERAL DEMOLITION NOTES: VERIFY EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR UNUSUAL CONDITIONS PHASE ALL WORK TO ACHIEVE THE MINIMUM DISTURBANCE IN WORK AREAS; PROTECT UNAFFECTED AREAS FROM DUST DIRT AND NOISE
Nava Companies 31 Union Square West, Suite 2D New York, NY 10003, USA
REMOVE ALL DEBRIS FROM THE SITE AND DISPOSE OF IN A MANNER APPROVED BY ALL LOCAL, STATE, AND FEDERAL REGULATIONS. PERFORM ALL DEMOLITION AND CARTING IN ACCORDANCE WITH THE BUILDING RULES AND REGULATIONS. BROOM SWEEP ALL PREMISES AND PUBLIC SPACES ON A DAILY BASIS.
Tel: 212.365.1052 www.navacompanies.com Mechanical Engineer: D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
SALVAGE EQUIPMENT, FIXTURES AND DOORS AS REQUIRED BY THE CONTRACT DOCUMENTS. REUSE AS DIRECTED ON DRAWINGS AND IN SCHEDULES. SALVAGE SPECIFIED DOORS AND ATTACHED HARDWARE FOR COURSE OF JOB. REMOVE THOSE NOT REUSED AT END OF JOB AS DIRECTED BY OWNER. SEE DOOR SCHEDULE FOR THOSE SALVAGED AND RELOCATED.
Structural Engineer: Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
REMOVE ALL MISCELLANEOUS ATTACHMENTS TO WALLS, FLOORS, CEILINGS, WINDOWS, AND DOORS INCLUDING, BUT NOT LIMITED TO, NAILS, HOOKS, WIRES, DOORBELLS, AND STOPS.
Key Plan:
SHUT OFF ALL EXISTING PLUMBING HOOK-UPS IMMEDIATELY PRIOR TO DEMOLITION WORK AT EACH LOCATION.
UP
REMOVE EXISTING FLOORING INCLUDING WOOD FLOOR, SADDLES, CARPET, TILE, STONE AND ALL SUB-FLOOR MATERIAL INCLUDING SLAB TOPPING. SALVAGE/ PRESERVE (E) WOOD FLOOR AS NOTED)
1
RESTORE TO VALUES SPECIFIED IN APPLICABLE CODES THE INTEGRITY OF EXISTING RATED PARTITIONS AND THE FIRE PROTECTION OF STRUCTURAL MEMBERS THAT ARE DAMAGED DURING CONSTRUCTION.
GROUND FLOOR DEMOLITION PLAN Scale: 1/4" = 1'0"
Legend: LEAVE AND PROTECT (E) WOOD FLOOR FOR REFINISHING
LEAVE AND PROTECT (E) WOOD FLOOR FOR REFINISHING
DEMOLISH (E) WINDOWS AND PORTION OF EXTERIOR WALL
DEMOLISH AND REMOVE (E) DECKING & SLEEPERS
PROVIDE A MINIMUM OF TWO (2) FIRE EXTINGUISHERS OR MORE AS REQUIRED BY NYC DOB. Notification:
REMOVE ALL PARTITION WALLS, MILLWORK, DOORS, DOOR CASINGS, WINDOW CASINGS, DECORATIVE FINISHES, SHELVING AS INDICATED.
COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
REMOVE ALL EXISTING CONSTRUCTION LOCATED IN A MANNER SO AS NOT TO CONFLICT WITH WORK SHOWN ON OTHER DRAWINGS. REMOVE AND REPLACE ANY OTHER CONSTRUCTION OUTSIDE LIMITS SHOWN, AS NECESSARY TO COMPLETE THE WORK.
UP
DEMOLISH AND REPLACE (E) WINDOW
Issue Description ISSUE
BRING ALL DEMOLITION AND REMOVAL TO A NATURAL STOPPING POINT. REPLACE ANY MATERIAL REMOVED BY MISTAKE OR IN EXCESS OF REQUIREMENTS. WHERE ALTERATIONS OCCUR OR NEW AND OLD WORK JOIN, CUT, REMOVE, PATCH, REPAIR, OR REFINISH THE ADJACENT SURFACES, AND REMOVE EXISTING WORK TO PROFILES SHOWN FOR NEW WORK SO AS TO LEAVE IN AS GOOD A CONDITION AS EXISTED PRIOR TO COMMENCING OF WORK. PROTECT ALL FINISHES TO REMAIN.
Date
LIVING
DINING
TERRACE
DEMOLISH AND REPLACE (E) WINDOW
HALL
PROTECT PUBLIC CORRIDORS AND SPACES FROM DAMAGE.
DEMOLISH AND REPLACE (E) WINDOW OFFICE
DEMOLISH AND REPLACE (E) WINDOW
UP
DN
KITCHEN
Date
Revision
PROTECT ALL MATERIALS, SURFACES AND FINISHES TO REMAIN. SALVAGE ALL DOOR HARDWARE, LABEL AND BAG FOR RESTORATION AND REUSE. REMOVE ALL DROPPED CEILINGS, SOFFITS AND EXPOSED CONCRETE SLAB FOR INSPECTION AND PREPARATION FOR NEW FINISHES. (E) SKYLIGHT
DISCONNECT AND REMOVE ALL EXISTING LIGHTING, ELECTRICAL BOXES, TELEPHONE EQUIPMENT, ELECTRICAL TERMINATIONS. SEE DEMOLITION AND ELECTRICAL NOTES FOR ADDITIONAL SAFETY REQUIREMENTS AND TEMPORARY LIGHTING REQUIREMENTS.
2
SECOND FLOOR DEMOLITION PLAN Scale: 1/4" = 1'0" Project Title:
RINKER RESIDENCE
REMOVE EXISTING RADIATOR ENCLOSURE AND HVAC EQUIPMENT INCLUDING ATTACHED DEVICES, DUCTING, GRILLS, CONDENSORS, AIR HANDLERS, PACKAGE UNITS DISCONNECT AND REMOVE ALL PLUMBING FIXTURES AND ASSOCIATED BRANCH PIPING AND CAP AT PLUMBING STACK LOCATIONS. SEE PLUMBING NOTES FOR ADDITIONAL REQUIREMENTS REDUCE CHASE SIZE AT ALL LOCATION OF BUILDING PLUMBING RISERS TO A MINIMUM. EXPOSE ALL RISERS FOR INSPECTION BY ARCHITECT AND BUILDING MANAGEMENT DEMISING WALLS, STRUCTURAL ELEMENTS TO BE REDUCED TO THE MINIMUM DIMENSION WITHOUT UNDERMINING REQUIRED FIRE RATING.
344 E 84TH STREET NEW YORK, NY 10028 BUILDING NOTES: INSPECTION, PROBING, AND EVALUATION OF EXISTING CONDITIONS HAS BEEN PERFORMED TO ENSURE THAT THE ALTERATION DESIGN WILL NOT CAUSE DAMAGE TO, DISRUPTION OF, OR RELOCATION AND MODIFICATION TO ANY STRUCTURAL ELEMENT INCLUDING SLABS, BEAMS, COLUMNS, PLUMBING RISERS, INTERCOM RISERS, PHONE RISERS, ELECTRICAL RISERS AND/OR VENTILATION CHASES/DUCTS. IN THE EVENT UNEXPECTED CONDITIONS ARE UNCOVERED AND/OR ALTERATION PLANS MUST BE MODIFIED IN ANY WAY, THE CONTRACTOR MUST NOTIFY BUILDING MANAGEMENT PRIOR TO PROCEEDING FURTHER. IF SIGNIFICANT ALTERATIONS TO THE APPROVED AND PERMITTED PLAN ARE REQUIRED AND THEY ARE PRESENTED AND APPROVED THROUGH MANAGMENT AND THE BUILDING CONSULTANT THE DOB PERMITS MUST BE AMENDED THROUGH THE PAA PROCESS AT THE DOB.
ALL WINDOWS TO BE DEMOLISHED DUST PROTECTION WITH PROPER PROTECTION AGAINST TRANSFER OF NOISE AND DUST AS WELL AS FUMES MUST BE IMPLEMENTED IMMEDIATELY UPON OPENING. ANY WORK PERFORMED CANNOT LOWER EXISTING FIRE RATINGS.
Floor Number:
FIRST & SECOND FLOOR DEMOLITION PLAN Seal & Signature:
Date: 5/26/2016 Project Number: Drawing: Checked: Drawing Number:
A-001.00
0440
Architect:
GENERAL DEMOLITION NOTES: VERIFY EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR UNUSUAL CONDITIONS LEAVE AND PROTECT (E) WOOD FLOOR FOR REFINISHING
PHASE ALL WORK TO ACHIEVE THE MINIMUM DISTURBANCE IN WORK AREAS; PROTECT UNAFFECTED AREAS FROM DUST DIRT AND NOISE REMOVE ALL DEBRIS FROM THE SITE AND DISPOSE OF IN A MANNER APPROVED BY ALL LOCAL, STATE, AND FEDERAL REGULATIONS. PERFORM ALL DEMOLITION AND CARTING IN ACCORDANCE WITH THE BUILDING RULES AND REGULATIONS. BROOM SWEEP ALL PREMISES AND PUBLIC SPACES ON A DAILY BASIS.
LEAVE AND PROTECT (E) WOOD FLOOR FOR REFINISHING
Nava Companies 31 Union Square West, Suite 2D New York, NY 10003, USA Tel: 212.365.1052 www.navacompanies.com Mechanical Engineer: DEMOLISH AND REPLACE (E) WINDOWS
DEMOLISH AND REPLACE (E) WINDOWS
SALVAGE EQUIPMENT, FIXTURES AND DOORS AS REQUIRED BY THE CONTRACT DOCUMENTS. REUSE AS DIRECTED ON DRAWINGS AND IN SCHEDULES.
D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
BEDROOM BEDROOM
SALVAGE SPECIFIED DOORS AND ATTACHED HARDWARE FOR COURSE OF JOB. REMOVE THOSE NOT REUSED AT END OF JOB AS DIRECTED BY OWNER. SEE DOOR SCHEDULE FOR THOSE SALVAGED AND RELOCATED.
Structural Engineer: DEMOLISH AND REPLACE (E) WINDOWS
DEMOLISH AND REPLACE (E) WINDOWS
REMOVE ALL MISCELLANEOUS ATTACHMENTS TO WALLS, FLOORS, CEILINGS, WINDOWS, AND DOORS INCLUDING, BUT NOT LIMITED TO, NAILS, HOOKS, WIRES, DOORBELLS, AND STOPS. SHUT OFF ALL EXISTING PLUMBING HOOK-UPS IMMEDIATELY PRIOR TO DEMOLITION WORK AT EACH LOCATION.
Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
Key Plan: HALL UP
DEMOLISH AND REPLACE (E) WINDOWS
DN
KITCHEN
DEMOLISH AND REPLACE (E) WINDOWS
REMOVE EXISTING FLOORING INCLUDING WOOD FLOOR, SADDLES, CARPET, TILE, STONE AND ALL SUB-FLOOR MATERIAL INCLUDING SLAB TOPPING. SALVAGE/ PRESERVE (E) WOOD FLOOR AS NOTED) RESTORE TO VALUES SPECIFIED IN APPLICABLE CODES THE INTEGRITY OF EXISTING RATED PARTITIONS AND THE FIRE PROTECTION OF STRUCTURAL MEMBERS THAT ARE DAMAGED DURING CONSTRUCTION.
Legend:
1
THIRD FLOOR DEMOLITION PLAN Scale: 1/4" = 1'0"
PROVIDE A MINIMUM OF TWO (2) FIRE EXTINGUISHERS OR MORE AS REQUIRED BY NYC DOB.
DEMOLISH AND REMOVE (E) DECKING
RELOCATE (E) CONDENSOR UNIT
Notification:
REMOVE ALL PARTITION WALLS, MILLWORK, DOORS, DOOR CASINGS, WINDOW CASINGS, DECORATIVE FINISHES, SHELVING AS INDICATED.
COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
REMOVE ALL EXISTING CONSTRUCTION LOCATED IN A MANNER SO AS NOT TO CONFLICT WITH WORK SHOWN ON OTHER DRAWINGS. REMOVE AND REPLACE ANY OTHER CONSTRUCTION OUTSIDE LIMITS SHOWN, AS NECESSARY TO COMPLETE THE WORK.
Issue Description
Date
ISSUE
BRING ALL DEMOLITION AND REMOVAL TO A NATURAL STOPPING POINT. REPLACE ANY MATERIAL REMOVED BY MISTAKE OR IN EXCESS OF REQUIREMENTS. WHERE ALTERATIONS OCCUR OR NEW AND OLD WORK JOIN, CUT, REMOVE, PATCH, REPAIR, OR REFINISH THE ADJACENT SURFACES, AND REMOVE EXISTING WORK TO PROFILES SHOWN FOR NEW WORK SO AS TO LEAVE IN AS GOOD A CONDITION AS EXISTED PRIOR TO COMMENCING OF WORK. PROTECT ALL FINISHES TO REMAIN.
ROOF DECK
PROTECT PUBLIC CORRIDORS AND SPACES FROM DAMAGE. Date
Revision
PROTECT ALL MATERIALS, SURFACES AND FINISHES TO REMAIN. SALVAGE ALL DOOR HARDWARE, LABEL AND BAG FOR RESTORATION AND REUSE. REMOVE ALL DROPPED CEILINGS, SOFFITS AND EXPOSED CONCRETE SLAB FOR INSPECTION AND PREPARATION FOR NEW FINISHES. DISCONNECT AND REMOVE ALL EXISTING LIGHTING, ELECTRICAL BOXES, TELEPHONE EQUIPMENT, ELECTRICAL TERMINATIONS. SEE DEMOLITION AND ELECTRICAL NOTES FOR ADDITIONAL SAFETY REQUIREMENTS AND TEMPORARY LIGHTING REQUIREMENTS.
2
FOURTH FLOOR DEMOLITION PLAN Scale: 1/4" = 1'0"
REDUCE CHASE SIZE AT ALL LOCATION OF BUILDING PLUMBING RISERS TO A MINIMUM. EXPOSE ALL RISERS FOR INSPECTION BY ARCHITECT AND BUILDING MANAGEMENT DEMISING WALLS, STRUCTURAL ELEMENTS TO BE REDUCED TO THE MINIMUM DIMENSION WITHOUT UNDERMINING REQUIRED FIRE RATING.
Project Title:
RINKER RESIDENCE
REMOVE EXISTING RADIATOR ENCLOSURE AND HVAC EQUIPMENT INCLUDING ATTACHED DEVICES, DUCTING, GRILLS, CONDENSORS, AIR HANDLERS, PACKAGE UNITS DISCONNECT AND REMOVE ALL PLUMBING FIXTURES AND ASSOCIATED BRANCH PIPING AND CAP AT PLUMBING STACK LOCATIONS. SEE PLUMBING NOTES FOR ADDITIONAL REQUIREMENTS
SALVAGE (E) GLASS SKYLIGHT
344 E 84TH STREET NEW YORK, NY 10028 BUILDING NOTES: INSPECTION, PROBING, AND EVALUATION OF EXISTING CONDITIONS HAS BEEN PERFORMED TO ENSURE THAT THE ALTERATION DESIGN WILL NOT CAUSE DAMAGE TO, DISRUPTION OF, OR RELOCATION AND MODIFICATION TO ANY STRUCTURAL ELEMENT INCLUDING SLABS, BEAMS, COLUMNS, PLUMBING RISERS, INTERCOM RISERS, PHONE RISERS, ELECTRICAL RISERS AND/OR VENTILATION CHASES/DUCTS. IN THE EVENT UNEXPECTED CONDITIONS ARE UNCOVERED AND/OR ALTERATION PLANS MUST BE MODIFIED IN ANY WAY, THE CONTRACTOR MUST NOTIFY BUILDING MANAGEMENT PRIOR TO PROCEEDING FURTHER. IF SIGNIFICANT ALTERATIONS TO THE APPROVED AND PERMITTED PLAN ARE REQUIRED AND THEY ARE PRESENTED AND APPROVED THROUGH MANAGMENT AND THE BUILDING CONSULTANT THE DOB PERMITS MUST BE AMENDED THROUGH THE PAA PROCESS AT THE DOB.
ALL WINDOWS TO BE DEMOLISHED DUST PROTECTION WITH PROPER PROTECTION AGAINST TRANSFER OF NOISE AND DUST AS WELL AS FUMES MUST BE IMPLEMENTED IMMEDIATELY UPON OPENING. ANY WORK PERFORMED CANNOT LOWER EXISTING FIRE RATINGS.
Floor Number:
THIRD & FOURTH FLOOR DEMOLITION PLAN Seal & Signature:
Date: 5/26/2016 Project Number: Drawing: Checked: Drawing Number:
A-002.00
0440
Architect: TENANT SAFETY PLAN:
5. 6.
Mechanical Engineer: D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
Structural Engineer: Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
Key Plan:
UP
Legend: 9'-8"
1
FIRST FLOOR CONSTRUCTION PLAN Scale: 1/4" = 1'0"
Notification: Powder Room #205 PROVIDE LATICRETE WATERPROOF, BITUTHENE WATERPROOFING AND SOUNDPROOF SYSTEM AT FLOOR AND EXTEND 6" UP ALL WALLS AND FULL HEIGHT ON ALL SHOWER WALLS. PROVIDE DUROCK WALLBOARD IN ALL TUB/SHOWER ENCLOSURES AND USG SHEETROCK MOLD TOUGH IN ALL OTHER AREAS, INCLUDING CEILING.
40'-014"
19'-2"
PROVIDE NEW STONE SADDLE INSTALL ALL TILE, MATERIAL TO BE PROVIDED BY CONTRACTOR.
16'-61
4"
5'-0"
14'-0"
INSTALL PLUMBING FIXTURES, FITTING AND ACCESSORIES PROVIDED BY CONTRACTOR. SEE FIXTURE SCHEDULE. FURNISH AND INSTALL ALL MILLWORK, MIRROR AND GLASS
COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
Issue Description
Date
ISSUE
Dining Area #202 FURNISH AND INSTALL ALL MILLWORK, MIRROR, GLASS AND TILE REFINISH & PATCH AS NECESSARY (E) WOOD FLOOR
5 Living Area #201
FURNISH AND INSTALL NEW BASE, DOORS, CASINGS AND TRIM
01 A-010
203
FURNISH AND INSTALL NEW SWING AND SLIDE WINDOW WALL
FURNISH AND INSTALL ALL MILLWORK, MIRROR , GLASS AND TILE ALL DOOR FRAMES AND SPECIAL CONSTRUCTION TO USE PT WOOD. ALL WOOD USED FOR BLOCKING IS TO BE FIRE-TREATED WITH NON-TOXIC MATERIAL. REFINISH & PATCH AS NECESSARY (E) WOOD FLOOR
02 A-010
03 A-010
1
FURNISH AND INSTALL NEW BASE, DOORS, CASINGS AND TRIM
202
FURNISH AND INSTALL NEW WINDOWS
200
UP
6'-012"
3'-6"
201
1
FURNISH AND INSTALL ALL MILLWORK.
Date
Revision
DW
2 MECH.
Terrace #206
FURNISH AND INSTALL NEW DECKING. SEE FINISH SCHEDULE.
2'-9"
4.
Tel: 212.365.1052 www.navacompanies.com
FURNISH AND INSTALL ALL SLAB / STONE. PROVIDE TEMPLATING AND FABRICATION.
2'-0" UP
3'-81 4"
3.1.
31 Union Square West, Suite 2D New York, NY 10003, USA
FURNISH AND INSTALL NEW EXTERIOR CONVENIENCE STAIR.
Kitchen #203
DN INSTALL ALL TILE, MATERIAL TO BE PROVIDED BY CONTRACTOR. FURNISH AND INSTALL ALL SLAB/STONE. PROVIDE TEMPLATING AND FABRICATION
2'-3"
3.
Nava Companies
18'-93 4"
2.
Egress. At all times in the course of construction provision shall be made for adequate egress as required by this code and the tenant protection plan shall identify the egress that will be provided. Required egress shall not be obstructed at any time except where approved by the commissioner. Fire safety. All necessary laws and controls, including those with respect to occupied dwellings, as well as additional safety measures necessitated by the construction shall be strictly observed. Health requirements. Specification of methods to be used for control of dust, disposal of construction debris, pest control and maintenance of sanitary facilities, and limitation of noise to acceptable levels shall be included. There shall be included a statement of compliance with applicable provisions of law relating to lead and asbestos. Compliance with housing standards. The requirements of the New York city housing maintenance code, and, where applicable, the New York state multiple dwelling law shall be strictly observed. Structural safety. No structural work shall be done that may endanger the occupants. Noise restrictions. Where hours of the day or the days of the week in which construction work may be undertaken are limited pursuant to the New York city noise control code, such limitations shall be stated.
21'-33 4"
1.
FURNISH AND INSTALL ALL APPLIANCES INSTALL PLUMBING FIXTURES, FITTING AND ACCESSORIES PROVIDED BY CONTRACTOR. SEE FIXTURE SCHEDULE.
9'-612"
3'-11" 12'-8"
2
SECOND FLOOR CONSTRUCTION PLAN Scale: 1/4" = 1'0"
12'-33 4"
1'-0"
12'-612"
2'-0"
FURNISH AND INSTALL ALL MILLWORK, MIRROR AND GLASS REFINISH & PATCH AS NECESSARY (E) WOOD FLOOR
Project Title:
RINKER RESIDENCE 344 E 84TH STREET NEW YORK, NY 10028 Floor Number:
Entry #200
FURNISH AND INSTALL NEW BASE, DOORS, CASINGS AND TRIM
FIRST FLOOR AND SECOND FLOOR CONSTRUCTION PLAN
LEAVE (E) CARPET AND TERMINATE (E) BANISTER AT NEW PARTITION
Seal & Signature:
FURNISH AND INSTALL ALL MILLWORK, MIRROR AND GLASS ALL DOOR FRAMES AND SPECIAL CONSTRUCTION TO USE PT WOOD. ALL WOOD USED FOR BLOCKING IS TO BE FIRE-TREATED WITH NON-TOXIC MATERIAL.
Date: 5/26/2016 Project Number: Drawing: Checked: Drawing Number:
A-003.00
0440
Architect:
Lounge #201 REFINISH AND PATCH AS NECESSARY (E) WOOD FLOOR FURNISH AND INSTALL ALL MILLWORK, MIRROR AND GLASS ALL DOOR FRAMES AND SPECIAL CONSTRUCTION TO USE PT WOOD. ALL WOOD USED FOR BLOCKING IS TO BE FIRE-TREATED WITH NON-TOXIC MATERIAL.
Nava Companies
FURNISH AND INSTALL NEW BASE, DOORS, CASINGS AND TRIM
31 Union Square West, Suite 2D New York, NY 10003, USA Tel: 212.365.1052 www.navacompanies.com
40'-014" 10'-014"
2'-0"
11'-2"
2'-0"
11'-6"
Mechanical Engineer: D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
3
Bedroom #301
3 2
INSTALL NEW FLOORING, MATERIAL TO BE PROVIDED BY CONTRACTOR.
2
Owen's Bedroom #301
FURNISH AND INSTALL NEW BASE, DOORS, CASINGS, TRIM
Structural Engineer:
REFINISH AND PATCH AS NECESSARY (E) WOOD FLOOR
ALL DOOR FRAMES AND SPECIAL CONSTRUCTION TO USE PT WOOD. ALL WOOD USED FOR BLOCKING IS TO BE FIRE-TREATED WITH NON-TOXIC MATERIAL.
FURNISH AND INSTALL NEW BASE, DOORS, CASINGS, TRIM
11'-53 4"
11'-67 8"
FURNISH AND INSTALL NEW MILLWORK, BUILT-IN CABINETS, SEE ELEVATIONS
FURNISH AND INSTALL NEW MILLWORK, BUILT-IN CABINETS, SEE ELEVATIONS
Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
REPLACE (E) WINDOWS
21'-33 4"
REPLACE (E) WINDOWS
Key Plan: 04 A-010
4
04 A-010
04 A-010.01
301
304
305
10'-03 8"
2'-512"
2'-1114"
4
2'-5"
306
2'-10"
Owen's Bathroom #302 PROVIDE LATICRETE WATERPROOFING AT FLOOR AND EXTEND 6" UP ALL WALLS AND FULL HEIGHT ON ALL SHOWER WALLS.
Bathroom #302 PROVIDE LATICRETE WATERPROOFING AT FLOOR AND EXTEND 6" UP ALL WALLS AND FULL HEIGHT ON ALL SHOWER WALLS.
6'-5"
6'-5"
302 UP DN
PROVIDE WATERPROOFING THROUGHOUT ENTIRETY OF NICHES IN SHOWER. AT WINDOW, EXTEND WP INTO THE FRAMED OPENING AND PROVIDE SEAL WHERE WP MEETS WINDOW FRAME. AT SILLS AND NICHE, SLOPE TO DRAIN 12" PER FOOT.
IN SHOWER PROVIDE LEAD PAN, CLAMPED AND SEALED INTO A NEW DRAIN COLLAR WHICH MUST CAP OVER THE CURB, EXTENDING A MIN. OF 12" ABOVE THE TOP OF THE CURB. DRAIN MUST HAVE WEEP HOLES. AFTER 24-HOUR WATER RETENTION TEST, ENTIRE LEAD PAN MUST BE COATED WITH MASTIC MEMBRANE, MASTERSEAL HLM 5000, PRIOR TO INSTALLATION OF MORTAR BED.
5
PROVIDE WATERPROOFING THROUGHOUT ENTIRETY OF NICHES IN SHOWER. AT WINDOW, EXTEND WP INTO THE FRAMED OPENING AND PROVIDE SEAL WHERE WP MEETS WINDOW FRAME. AT SILLS AND NICHE, SLOPE TO DRAIN 1 2" PER FOOT.
PROVIDE DUROCK WALLBOARD IN ALL TUB/SHOWER ENCLOSURES AND USG SHEETROCK MOLD TOUGH IN ALL OTHER AREAS, INCLUDING CEILING. PROVIDE NEW STONE SADDLE
20'-81 4"
7'-9"
8'-3"
Legend:
PROVIDE DUROCK WALLBOARD IN ALL TUB/SHOWER ENCLOSURES AND USG SHEETROCK MOLD TOUGH IN ALL OTHER AREAS, INCLUDING CEILING.
FURNISH AND INSTALL ALL SLAB/STONE, PROVIDE TEMPLATING AND FABRICATION
PROVIDE NEW STONE SADDLE
INSTALL ALL TILE, MATERIAL TO BE PROVIDED BY CONTRACTOR.
THIRD FLOOR CONSTRUCTION PLAN 1 Scale: 1/4" = 1'0"
INSTALL PLUMBING FIXTURES, FITTING AND ACCESSORIES PROVIDED BY CONTRACTOR. SEE FIXTURE SCHEDULE.
INSTALL ALL TILE, MATERIAL TO BE PROVIDED BY CONTRACTOR. INSTALL PLUMBING FIXTURES, FITTING AND ACCESSORIES PROVIDED BY CONTRACTOR. SEE FIXTURE SCHEDULE.
FURNISH AND INSTALL ALL MILLWORK, MIRROR AND GLASS
FURNISH AND INSTALL ALL MILLWORK, MIRROR AND GLASS
REPLACE (E) WINDOW
REPLACE (E) WINDOW
CORRIDOR # 300 REFINISH AND PATCH AS NECESSARY (E) WOOD FLOOR
Notification: COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
FURNISH AND INSTALL ALL MILLWORK, MIRROR AND GLASS ALL DOOR FRAMES AND SPECIAL CONSTRUCTION TO USE PT WOOD. ALL WOOD USED FOR BLOCKING IS TO BE FIRE-TREATED WITH NON-TOXIC MATERIAL.
Issue Description
Date
ISSUE
FURNISH AND INSTALL NEW BASE, DOORS, CASINGS AND TRIM
Master Bath #403 PROVIDE LATICRETE WATERPROOF, BITUTHENE WATERPROOFING AT FLOOR AND EXTEND 6" UP ALL WALLS AND FULL HEIGHT ON ALL SHOWER WALLS. IN SHOWER PROVIDE LEAD PAN, CLAMPED AND SEALED INTO A NEW DRAIN COLLAR WHICH MUST CAP OVER THE CURB, EXTENDING A MIN. OF 4" ABOVE THE TOP OF THE CURB. DRAIN MUST HAVE WEEP HOLES. AFTER 24-HOUR WATER RETENTION TEST, ENTIRE LEAD PAN MUST BE COATED WITH MASTIC MEMBRANE, MASTERSEAL HLM 5000, PRIOR TO INSTALLATION OF MORTAR BED.
Office #401 INSTALL NEW FLOORING, MATERIAL TO BE PROVIDED BY CONTRACTOR.
47'-01 4"
FURNISH AND INSTALL ALL MILLWORK, MIRROR AND GLASS
10'-23
5'-4"
PROVIDE WATERPROOFING THROUGHOUT ENTIRETY OF NICHES IN SHOWER. AT WINDOW, EXTEND WP INTO THE FRAMED OPENING AND PROVIDE SEAL WHERE WP MEETS WINDOW FRAME. AT SILLS AND NICHE, SLOPE TO DRAIN 12" PER FOOT.
9'-87
4"
11'-73
8"
4"
6'-6"
5
FURNISH AND INSTALL ALL SLAB/STONE, PROVIDE TEMPLATING AND FABRICATION. INSTALL PLUMBING FIXTURES, FITTINGS, AND ACCESSORIES PROVIDED BY CONTRACTOR. SEE FIXTURE SCHEDULE.
PROVIDE DUROCK WALLBOARD IN ALL TUB/SHOWER ENCLOSURES AND USG SHEETROCK MOLD TOUGH IN ALL OTHER AREAS, INCLUDING CEILING.
ALL DOOR FRAMES AND SPECIAL CONSTRUCTION TO USE PT WOOD. ALL WOOD USED FOR BLOCKING IS TO BE FIRE-TREATED WITH NON-TOXIC MATERIAL.
6
7'-13 4"
2'-107 8"
FURNISH AND INSTALL ALL MILLWORK, MIRROR AND GLASS
4 6'-218"
21'-33 4"
INSTALL NEW WINDOWS
4
18'-93 4"
5
INSTALL PLUMBING FIXTURES, FITTING AND ACCESSORIES PROVIDED BY CONTRACTOR. SEE FIXTURE SCHEDULE.
11'-1012"
INSTALL ALL TILE, MATERIAL TO BE PROVIDED BY CONTRACTOR.
INSTALL NEW WINDOWS
02 A-010.01
04 A-010
403
3'-6"
FURNISH AND INSTALL ALL SLAB/STONE, PROVIDE TEMPLATING AND FABRICATION
Date
Revision
15'-33 4"
5'-83 8"
PROVIDE NEW STONE SADDLE
4
Project Title: 12'-83 8"
402
4'-112"
3'-0"
7'-3" 4'-0"
01 A-011
Master Bedroom #401
01 A-010.01 401
404
344 E 84TH STREET NEW YORK, NY 10028
05 A-010 DN
INSTALL NEW FLOORING, MATERIAL TO BE PROVIDED BY CONTRACTOR. 405
FURNISH AND INSTALL ALL MILLWORK, MIRROR AND GLASS
6
ALL DOOR FRAMES AND SPECIAL CONSTRUCTION TO USE PT WOOD. ALL WOOD USED FOR BLOCKING IS TO BE FIRE-TREATED WITH NON-TOXIC MATERIAL.
RINKER RESIDENCE
12'-0"
4
1
Floor Number:
UP
DN
THIRD AND FOURTH FLOOR CONSTRUCTION PLAN
6
INSTALL NEW WINDOWS FURNISH AND INSTALL NEW BASE, DOORS, CASINGS AND TRIM
12'-0"
13'-35 8"
2'-4"
9'-018"
Seal & Signature:
Date: 5/26/2016 Project Number: Drawing:
2
FOURTH FLOOR CONSTRUCTION PLAN Scale: 1/4" = 1'0"
Checked: CORRIDOR #400
Drawing Number:
INSTALL NEW FLOORING, MATERIAL TO BE PROVIDED BY CONTRACTOR. FURNISH AND INSTALL ALL MILLWORK, MIRROR AND GLASS ALL DOOR FRAMES AND SPECIAL CONSTRUCTION TO USE PT WOOD. ALL WOOD USED FOR BLOCKING IS TO BE FIRE-TREATED WITH NON-TOXIC MATERIAL. FURNISH AND INSTALL NEW BASE, DOORS, CASINGS AND TRIM
A-004.00
0440
Architect:
ROOF TERRACE FURNISH AND INSTALL NEW DECKING AND HANDRAIL FURNISH AND INSTALL NEW GAS FIRE PIT
Nava Companies
FURNISH AND INSTALL ALL MILLWORK AND FIXED SEATING
40'-01
FURNISH AND INSTALL ALL PLUMBING FIXTURES
31 Union Square West, Suite 2D New York, NY 10003, USA
4"
36'-01 4"
Tel: 212.365.1052 www.navacompanies.com Mechanical Engineer: D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
Structural Engineer:
ROOF TERRACE
18'-113 8"
21'-33 4"
Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
Key Plan:
OPEN TO BELOW
DN
12'-103 8"
15'-0"
Legend:
3'-0"
Notification:
1
COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
ROOF CONSTRUCTION PLAN Scale: 1/4" = 1'0"
Issue Description
Date
ISSUE STC 56 BSA #301-60-SM
5
STC 48 BSA #301-60-SM
618"
47 8"
35 8"
35 8"
5 8" 8"
5
5 8" 8"
5
8"
STC 48 BSA #301-60-SM 612"
27 8" 15 8" 5
UNDERSIDE OF SLAB
UNDERSIDE OF SLAB
35 8"
51 4" 5
8"
53 4"
5 8" 8"
5
5
8"
5
8"
8"
5
8"
1
8"
3
8"
4"
UNDERSIDE OF SLAB
UNDERSIDE OF SLAB
PERIMETER SEALANT
UNDERSIDE OF SLAB
BATT INSULATION CUT TOP COURSE, FILL WITH NON SHRINK GROUT TIGHT TO SLAB STEEL TRACK
STEEL TRACK
STEEL TRACK
STEEL TRACK
Date
Revision
STEEL TRACK 3 5 8" BATT INSULATION
3 5 8" BATT INSULATION
3 5 8" BATT INSULATION
3 5 8" BATT INSULATION EXTEND CEMENT BOARD TO UNDERSIDE OF SLAB, GROUT AND SEAL AT ENDS AS REQUIRED
(2) LAYERS 3 4" PLYWOOD EXTEND GWB TO UNDERSIDE OF SLAB, GROUT AND SEAL AT ENDS AS REQUIRED
EXTEND GWB TO UNDERSIDE OF SLAB, GROUT AND SEAL AT ENDS AS REQUIRED
EXTEND GWB TO UNDERSIDE OF SLAB, GROUT AND SEAL AT ENDS AS REQUIRED
13 4"
1 5 8" STEEL TRACK
3
4" STONE SLAB OR TILE ON EPOXY
1 1 2" RIGID INSULATION
WATERPROOF MEMBRANE, FULL HEIGHT
1
VARIES
8" THK. MASONITE PAINTED BLACK
Project Title:
3 5 8" 18 GAUGE STEEL STUDS AT 16 INCHES ON CENTER 1 5 8" 18 GAUGE STEEL STUDS AT 16 INCHES ON CENTER 5
3 8" 18 GAUGE STEEL STUDS AT 16 INCHES ON CENTER
3 8" 18 GAUGE STEEL STUDS AT 16 INCHES ON CENTER
5
8" TYPE 'X' GWB BOTH SIDES, TAPE AND (3) COATS SPACKLE, USE GREENBOARDS AT ALL WET LOCATIONS
5 8" TYPE 'X' GWB BOTH SIDES, TAPE AND (3) COATS SPACKLE, USE GREENBOARDS AT ALL WET LOCATIONS
STEEL TRACK
STEEL TRACK
3" REBAR AT 48" ON CENTER DRILL AND EXPOXY INTO LAB; GROUT CORES SOLID AT BARS
5 8" TYPE 'X' GWB BOTH SIDES, TAPE AND (3) COATS SPACKLE, USE GREENBOARDS AT ALL WET LOCATIONS
5
5 8" TYPE 'X' GWB BOTH SIDES, TAPE AND (3) COATS SPACKLE, USE GREENBOARDS AT ALL WET LOCATIONS
RINKER RESIDENCE 344 E 84TH STREET NEW YORK, NY 10028
STEEL TRACK
5
8" TYPE 'X' GWB BOTH SIDES, TAPE AND (3) COATS SPACKLE, USE GREENBOARDS AT ALL WET LOCATIONS
Floor Number: 3
4"
STONE SLAB ON EPOXY
TYPICAL STONE/TILE FLOOR ASSEMBLY
STEEL TRACK
CMU; SEE PLANS FOR BLOCK SIZE AND LOCATION; USE GROUND FACE CMU AR EXTERIOR LOCATIONS AT ROOF
ROOF CONSTRUCTION PLAN AND WALL TYPES Seal & Signature:
Date: 5/26/2016 Project Number: Drawing: Checked: Drawing Number:
1
Wall Type: 2 Hour Partition Scale: 3" = 1'0"
2
Wall Type: 1 Hour Partition Scale: 3" = 1'0"
3
Wall Type: Furring Scale: 3" = 1'0"
4
Wall Type: Pocket Wall Scale: 3" = 1'0"
5
Wall Type: 1 Hour Partition w/ Waterproof Membrane Scale: 3" = 1'0"
6
Wall Type: Exterior CMU Scale: 3" = 1'0"
A-005.00
0440
Architect:
ELECTRICAL NOTES
RCP LEGEND
CONTRACTOR TO VERIFY THAT ALL EQUIPMENT AND APPLIANCES ARE COMPATIBLE WITH EXISTING POWER. CONTRACTOR IS RESPONSIBLE FOR MAKING ALL REQUIRED ADJUSTMENTS AND CHANGES.
(E) Ceiling height, patch as required
New GWB Drop Ceiling: See Elevations for Heights. Minimize drop.
GENERAL A). PROVIDE LOAD LETTER CONFIRMING THAT THE EXISTING ELECTRICAL SERVICE IS ADEQUATE FOR THE DEVICES, EQUIPMENT, AND FIXTURES SPECIFIED. CONTRACTOR TO EXTEND SERVICE FROM HALLWAY PANEL IF ADDITIONAL POWER IS REQUIRED, ACCORDING TO THE STANDARDS, SYSTEMS, AND SPECIFICATIONS OF THE BUILDING MANAGEMENT. RESTORE ALL EXISTING DISTURBED WORK TO ITS ORIGINAL CONDITION INCLUDING MAINTENANCE OF WIRING CONTINUITY AS REQUIRED. B). PROVIDE ALL FIXTURES, WIRING, AND ELECTRICAL OUTLETS, TELECOMMUNICATIONS WIRING, DEVICES, AND CATV AS INDICATED ON THE DRAWINGS. INSTALL ALL LIGHT FIXTURES PROVIDED BY OWNER. C). ALL WIRING DEVICES TO BE LUTRON ARCHITECTURAL STYLE. D). ELECTRICAL WORK TO INCLUDE IN-WALL TELEPHONE WIRING FROM THE NYNEX ENTRY TO ALL OUTLETS. WALL JACKS TO BE LEVITON TYPE 625. E). ELECTRICAL WORK TO INCLUDE IN-WALL WIRING FOR TV . OUTLETS TO BE DECORA TYPE. F). ELECTRICIAN TO BE RESPONSIBLE FOR DESIGN OF ALL CIRCUITS AND DISTRIBUTION AND FOR ALL REQUIRED PERMITS, INSPECTIONS AND APPROVALS FROM BOTH GOVERNMENT AGENCIES AND THE POWER UTILITY. G). REFER TO AV DRAWINGS FOR SCOPE OF WORK ALLOCATION H). PROVIDE GANG BOXES AND PLATES AS PER DIAGRAM. I). ALL SMOKE DETECTORS TO BE HARDWIRED. J). NO ALUMINUM WIRING PERMITTED. K). PROVIDE PIGTAILS AT ALL JUNCTION BOXES INDICATED ON DRAWINGS. INCLUDE INSTALLATION OF FIXTURES PROVIDED BY OWNER AT THOSE LOCATIONS. L). UNLESS OTHERWISE NOTED, LOCATE ALL CEILING BOXES ON THE CENTER LINE OF THE ROOM IN 2 DIRECTIONS AND LOCATE ALL WALL BOXES ON THE CENTER OF THAT WALL. CONFIRM LOCATION OF ALL BOXES WITH ARCHITECT. M). MOUNT ALL SWITCHES AT 4'-0" ABOVE FINISHED FLOOR AND RECEPTACLES IN BASEBOARD (UNLESS OTHERWISE NOTED.
ELECTRICAL SPECIFICATIONS
TV
WP 3" LED Low-Profile Fixed Waterproof Downlight.
31 Union Square West, Suite 2D New York, NY 10003, USA Tel: 212.365.1052 www.navacompanies.com
TV
Mechanical Engineer: 3" LED Low-Profile Adjustable Downlight.
Specialty Fixture To Be Determined: Locate on Site With Architect
D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
Wall Sconce To Be Determined: Locate on Site with Architect
Structural Engineer: Fixture Switched to Door
STD
GFI
DCTD
Smoke/CO Detector, Hardwired, BRK Brands SC7010B
DW
MECH.
Existing or Proposed Ceiling Clear Height. Coordinate with Elevations
UP
Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
Key Plan:
Static Pressure Vent
S
DCTD
DCTD
LUTRON: STWD-5BRL, Color and Engraving TBD
GFI
Closet Light, iO Line .75 Undercabinet Light, iO Line .75
1
SECOND FLOOR REFLECTED CEILING PLAN & POWER PLAN Scale: 1/4" = 1'0"
Legend:
ADDITIONAL NOTES 1 Locate Specialty Fixtures and Sconces On-Site with Architect as Shown. 2. Maximize Clear Ceiling Height Where Possible. Consult with Architect After Demolition.
POWER/ELEC. LEGEND WIRE SYM
PLAN DESCRIPTION SYM
TV
Television Outlet, Install at 57"
GFI
Duplex Ground Fault Interupt Convenience Outlet, 15 amp
Notification: COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
Issue Description
Date
ISSUE Duplex Convenience Outlet, 15 amp
TV
FEEDERS AND CIRCUITS: A). PROVIDE ANY AND ALL MATERIALS, EQUIPMENT. LABOR, ETC... NECESSARY FOR THE COMPLETE INSTALLATION OF ALL BRANCH CIRCUITS TO EQUIPMENT, RECEPTACLES AND LIGHTING OUTLETS, AND WIRING FOR CONTROL EQUIPMENT FURNISHED BY OTHERS, ETC... B). WHERE REQUIRED, FURNISH AND INSTALL SAFETY TYPE DISCONNECT SWITCHES, FUSED OR UNFUSED, WITH PROPER POLES AND NEUTRALS, AS EACH CASE REQUIRED, IF THE EQUIVALENT IS NOT EXISTING OR FURNISHED BY OTHERS, AND IS NECESSARY TO CONFORM TO CODE. C). PROVIDE MATCHING RECEPTACLES FOR ALL EQUIPMENT FURNISHED WITH CORD AND PLUG. D). MAKE DIRECT CONNECTIONS AS REQUIRED TO ALL EQUIPMENT NOT FURNISHED WITH CORD AND PLUG. CONDUITS: A). APARTMENT PANEL FEEDER SHALL BE HEAVY-WEIGHT, RIGID, GALVANIZED TYPE. B). GREENFIELD AND THINWALL TUBING MAY BE USED IN HUNG CEILING AND PARTITIONS AS PERMITTED BY CODE AND LABOR AGREEMENTS. C). NO EXPOSED CIRCUITING. DEMOLITION: A). DO ALL NECESSARY DEMOLITION AND REMOVAL OF EXISTING LIGHTING AND ELECTRICAL EQUIPMENT AS REQUIRED. B). REROUTE AND RECONNECT ALL CIRCUITING TO EXISTING LOADS WHICH ARE TO REMAIN IF SAME IS DISTURBED BY DEMOLITION WORK. PROVIDE NEW HOMERUNS, IF REQUIRED. C). CONDUITS COMING UP OUT OF FLOOR SLAB WHICH ARE TO BE REMOVED SHALL BE CUT BACK BELOW TOP OF FINISHED SLAB TO PERMIT PATCHING. D). DISCONNECT AND REMOVE ALL EXISTING WIRING AND EXPOSED CONDUITS NOT BEING RETAINED OR REUSED. E). INSTALL BLANK PLATES ON ALL EXISTING OUTLETS WHICH ARE TO REMAIN BUT HAVE NO DEVICES. F).PROVIDE EXTENSION COLLARS ON EXISTING OUTLETS WHERE EXISTING WALLS, COLUMNS, ETC... ARE BEING LAMINATED OR FURRED-OUT. G). RELOCATE EXISTING ACTIVE OUTLET BOXES, JUNCTION BOXES, ETC... WHICH ARE RENDERED INACCESSIBLE BY NEW CONSTRUCTION. TEMPORARY LIGHT AND POWER: A). POWER SHALL BE OBTAINED FROM THE EXISTING APARTMENT PANEL FEEDER. B). PROVIDE NECESSARY MATERIALS AND LABOR TO MAKE POWER CONNECTIONS FOR MACHINES, PORTABLE TOOLS, ETC... AS USED BY OTHER TRADES, REGARDLESS OF SIZE. C). FURNISH ALL LABOR NEEDED TO KEEP THIS TEMPORARY SYSTEM ENERGIZED DURING THE ENTIRE STANDARD PERIOD OF WORKING TIME OF ALL TRADES, PLUS 15 MINUTES BEFORE AND 15 MINUTES AFTER THIS TIME AND OVERTIME AS REQUIRED FOR ANY AND ALL TRADES. NEW LIGHTING AND APPLIANCE PANEL: A). FURNISH AND INSTALL LIGHTING AND APPLIANCE PANEL AS INDICATED ON PLANS, OF THE CIRCUIT BREAKER TYPE, CONSTRUCTED FOR A ONE (1) PHASE, THREE (3) WIRE, SOLID NEUTRAL, 120/208 VOLT SYSTEM. B). TIE-BARS SHALL NOT BE USED TO CREATE MULTI-POLE CIRCUITS. C). ONLY ONE WIRE SHALL BE INSTALLED UNDER EACH CIRCUIT BREAKER. D). PANELBOARD SHALL BE MOUNTED IN CODE GAUGE AND SIZE BOX(ES) FOR MOUNTING AS INDICATED ON PLANS, COMPLETE WITH TRIM AND DOOR. E). BRANCHES SHALL BE SINGLE POLE CIRCUIT BREAKERS IN GENERAL, AND SHALL BE 15 AMPERE FOR RECEPTACLE AND LIGHTING, 20 AMPERE FOR RECEPTACLES, AND OTHER SIZES AS NOTED ON PLANS. F). INSTALL ACCURATE DIRECTORY INSIDE PANEL DOOR. CATV / TELEPHONE SERVICE: A). PROVIDE ALL POWER SUPPLY OUTLETS AS NOTED AND REQUIRED BY THE TELEPHONE COMPANY FOR USE WITH ITS EQUIPMENT. B). PROVIDE ALL BUSHINGS ON EACH END OF TELEPHONE CONDUITS. C). EXACT EXTENT OF WORK REQUIRED SHALL BE DETERMINED FROM THE TELEPHONE COMPANY REPRESENTATIVE PRIOR TO COMMENCING WORK. D). ELECTRICAL WORK TO INCLUDE IN-WALL TELEPHONE AND CATV WIRING FROM THE UTILITY ENTRY TO APARTMENT TO ALL OUTLETS. WALL JACKS TO BE LEVITON TYPE 625 AND 406 81. WALL TELEPHONE OUTLET TO BE TYPE 630. ALL TELEPHONE LOCATIONS TO HAVE ACCESS TO 4 LINES. E). ALL CATV AND TELEPHONE OUTLETS TO HAVE HOMERUNS TO PANEL AT LOCATION INDICATED.
3" LED Low-Profile Fixed Downlight.
Nava Companies
Quad Convenience Outlet
WP
DCTD
Dedicated Duplex Appliance Outlet (consult appliance schedule and manufacturer for electrical specifications)
S
Switched Duplex Outlet
S
1/2 Switched Duplex Outlet
SHD
Motorized Shade Power
WP
GFI DCTD
GFI
TEL
TEL
Telephone Distribution Point
HUB
NET
Computer Network Distribution Point
DBI
DBI
Door Box Intercom
Date
Revision
TSTAT TSTAT Thermostat Locations Telephone Cable Wall Mounted Phone Floor Telephone
NOTES THIRD FLOOR REFLECTED CEILING PLAN & POWER PLAN 2 Scale: 1/4" = 1'0"
GROUNDING:
A). WHERE EXISTING WIRING WHICH IS TO REMAIN IS LEFT EXPOSED BY THE DEMOLITION AND REMOVAL OF PARTITIONS AND/OR HUNG CEILINGS, REROUTE SUCH WIRING AS REQUIRED TO MAINTAIN THE CIRCUIT CONTINUITY. 1. GROUNDING CONNECTIONS SHALL BE MADE TO THE NON-CONDUCTIVE CARRYING PARTS OF ALL ELECTRICAL EQUIPMENT AS B). WHERE EXISTING WIRING WHICH IS TO REMAIN IS LEFT STUBBED UP FROM FLOOR BY THE DEMOLITION AND REMOVAL OF NOTE: REQUIRED. PARTITIONS RE-ROUTE SUCH WIRING AS REQUIRED TO MAINTAIN CIRCUIT CONTINUITY AND CUT BACK CONDUIT BELOW TOP OF 1. SHOP DRAWINGS FOR ALL LIGHTING AND LOW VOLTAGE CONTROL SYSTEMS TO BE SUBMITTED TO THE ARCHITECT FOR REVIEW. ELECTRICAL SERVICE: FINISHED SLAB TO PERMIT PATCHING. MATERIALS: 1. EXISTING BUILDING INCOMING ELECTRIC SERVICE SHALL BE UTILIZED FOR THIS WORK. C). WHERE EXISTING CIRCUITING IS BEING UTILIZED FOR CONNECTION OF NEW LOAD OR IS BEING RETAINED FOR EXISTING LOADS 1. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND IN GOOD CONDITION AND HAVE UNDERWRITER'S LABORATORIES LABELS. 2. MAKE ALL NECESSARY MODIFICATIONS, EXTENSIONS, ETC... AS NOTED ON PLANS AND/OR REQUIRED. AND SUCH CIRCUITING IS NOT EXACTLY AS INDICATED ON PLANS, MAKE SUCH MODIFICATIONS AS MAY BE REQUIRED TO WIRING TO 2. ANY MATERIALS AND/OR EQUIPMENT WHICH THE DESIGNER AND ARCHITECT REGARDS AS UNSATISFACTORY SHALL NOT BE INSTALLED; OTHER MATERIALS 3. ENTIRE INSTALLATION SHALL BE IN FULL ACCORDANCE WITH ALL REQUIREMENTS OF THE CONSOLIDATED EDISON COMPANY AND ACCOMPLISH THE DESIGN INTENT. OR EQUIPMENT SHALL BE SUBMITTED AND IF CONSIDERED NECESSARY TO REQUEST PARTICULAR ITEMS BY NAME AND/OR CATALOG NUMBER, SUCH THE SHERRY NETHRTLAND. D). WHERE EXISTING LIGHTING, EQUIPMENT, WIRING, ETC... IS INDICATED AS REMAINING AND SUCH ITEMS INTERFERE WITH THE REQUESTS SHALL BE COMPLIED WITH, WITHOUT ADDITIONAL CHARGE. CONDUCTORS: INSTALLATION OR DEMOLITION WORK OF OTHER TRADES, BUT WILL NOT CONFLICT WITH SAME AFTER WORK IS COMPLETED, 3. MATERIALS AND EQUIPMENT SHALL BE SPECIFIED IN OTHER PARAGRAPHS NOTED ON PLANS, OR SUBJECT TO APPROVAL, BASED UPON ADAPTABILITY FOR 1. ALL BRANCH CIRCUIT CONDUCTORS MAY BE TYPE TW FOR FIFTEEN AND TWENTY AMPERE CIRCUITS. ALL SIZES INDICATED ON DISCONNECT, REMOVE, RELOCATE TO AVOID CONFLICTS, REINSTALL AND RECONNECT SUCH ITEMS AS REQUIRED. INTENDED USE. PLANS ARE BASED UPON THW COPPER WIRE. E). WHERE EXISTING LIGHTING, EQUIPMENT, WIRING, ETC... IS TO REMAIN AND SUCH WIRING IS FOUND TO BE DEFECTIVE, MAKE ALL WORKMANSHIP: 2. ALL CONDUCTORS #8 AND SMALLER SHALL BE SOLID, #6 AND LARGER SHALL BE STRANDED. CORRECTIONS AND REPLACEMENTS NECESSARY TO ELIMINATE THE DEFECT AND PUT SUCH ITEMS IN SATISFACTORY OPERATING 1. INSTALL CONDUITS CAREFULLY AND PROTECT AGAINST DAMAGE, REMOVING ALL CRUSHED OR DAMAGED CONDUITS. CAP OR PLUG ENDS TO PROTECT PIPE SLEEVES, SUPPORTS AND INSERTS: CONDITION. AGAINST DIRT OR MOISTURE BEFORE PULLING WIRES. 1. WHERE PIPES PASS THROUGH MASONRY, CONCRETE WALLS OR FLOORS, SET SUCH SLEEVES AS ARE NECESSARY FOR THE CUTTING AND PATCHING: 2. ALL CONDUITS SHALL BE SUPPORTED WITH APPROPRIATE HANGERS AT NOT OVER 8 FOOT INTERVALS. RUN EXPOSED CONDUITS PARALLEL OR PASSAGE OF THE PIPES. A). DO ALL THE REQUIRED CUTTING OF THE STRUCTURE NECESSARY FOR THE INSTALLATION OF THIS WORK. NO CUTTING LIKELY TO PERPENDICULAR TO WALLS. USE APPROPRIATE FITTINGS FOR ALL BENDS, ETC... 2. SLEEVES SHALL NOT BE USED IN ANY PORTION OF THE BUILDING WHERE THE USE OF SAME WOULD IMPAIR THE STRENGTH OF WEAKEN THE STRUCTURE (OR ANY PART THEREOF) SHALL BE DONE WITHOUT THE WRITTEN APPROVAL OF THE OWNER. 3. PROVIDE ALL LOCKNUTS AND BUSHINGS AS REQUIRED WHERE CONDUITS ENTER BOXES, CABINETS, ETC... CONSTRUCTION FEATURES OF THE BUILDING. B). PATCHING SHALL BE DONE BY THE GENERAL CONTRACTOR. 4. NOT MORE THAN THREE RIGHT-ANGLE BENDS, OR THEIR EQUIVALENT, SHALL BE MADE IN CONDUIT BETWEEN PULLBOXES. 3. SLEEVES PASSING THROUGH WALLS WHERE SUBJECT TO LEAKAGE SHALL BE CAULKED TO OBTAIN A WATER-TIGHT JOINT. 5. LEAVE A DRAG WIRE IN EVERY SPARE OR EMPTY CONDUIT. 6. NOTHING SHALL BE DONE WHICH WILL IN ANY MANNER ENDANGER OR UNDERMINE THE STRUCTURE OR ANY PART THEREOF.
JOB CONDITIONS:
1) All wires should be terminated in a box mounted straight and level at each location unless otherwise noted. 2) All wires are run from their marked location to the main equipment area unless otherwise noted. 3) All wires must be labeled on both ends using the same room names. 4) All power for TV and equipment locations to be on the same phase and within 18" of the wiring point. 5) Do not run any wire parallel to or within 3ft of line voltage electrical power runs. The longer the run, the greater the signal degredation. 6) Cross power lines at 90 degrees whenever possible. 7) All electrical boxes must be minimum 3" deep. All 1-gang boxes should be 1900 box with single gang collar. All Volume Controls (VC) will use mud rings in place of Electrical Boxes. 8) All associated low voltage wire to be supplied by Innovative Audio unless otherwise noted. 9) Avoid running low voltage wire within 10 ft. of high voltage lines, 200 amp feeds, etc. 10) All EQ runs require a 10 ft tail outside of the wall unless otherwise noted. All other locations require a minimum 3 ft tail. 11) See Wire Schedule and GC Scope of Work for more information. 12) Power requirements to be verified by General Contractor
Project Title:
RINKER RESIDENCE 344 E 84TH STREET NEW YORK, NY 10028 Floor Number:
SECOND & THIRD FLOOR RCP & POWER PLAN Seal & Signature:
Date: 5/26/2016 Project Number: Drawing: Checked: Drawing Number:
A-006.00
0440
Architect:
ELECTRICAL NOTES
RCP LEGEND
CONTRACTOR TO VERIFY THAT ALL EQUIPMENT AND APPLIANCES ARE COMPATIBLE WITH EXISTING POWER. CONTRACTOR IS RESPONSIBLE FOR MAKING ALL REQUIRED ADJUSTMENTS AND CHANGES.
(E) Ceiling height, patch as required
New GWB Drop Ceiling: See Elevations for Heights. Minimize drop.
GENERAL A). PROVIDE LOAD LETTER CONFIRMING THAT THE EXISTING ELECTRICAL SERVICE IS ADEQUATE FOR THE DEVICES, EQUIPMENT, AND FIXTURES SPECIFIED. CONTRACTOR TO EXTEND SERVICE FROM HALLWAY PANEL IF ADDITIONAL POWER IS REQUIRED, ACCORDING TO THE STANDARDS, SYSTEMS, AND SPECIFICATIONS OF THE BUILDING MANAGEMENT. RESTORE ALL EXISTING DISTURBED WORK TO ITS ORIGINAL CONDITION INCLUDING MAINTENANCE OF WIRING CONTINUITY AS REQUIRED. B). PROVIDE ALL FIXTURES, WIRING, AND ELECTRICAL OUTLETS, TELECOMMUNICATIONS WIRING, DEVICES, AND CATV AS INDICATED ON THE DRAWINGS. INSTALL ALL LIGHT FIXTURES PROVIDED BY OWNER. C). ALL WIRING DEVICES TO BE LUTRON ARCHITECTURAL STYLE. D). ELECTRICAL WORK TO INCLUDE IN-WALL TELEPHONE WIRING FROM THE NYNEX ENTRY TO ALL OUTLETS. WALL JACKS TO BE LEVITON TYPE 625. E). ELECTRICAL WORK TO INCLUDE IN-WALL WIRING FOR TV . OUTLETS TO BE DECORA TYPE. F). ELECTRICIAN TO BE RESPONSIBLE FOR DESIGN OF ALL CIRCUITS AND DISTRIBUTION AND FOR ALL REQUIRED PERMITS, INSPECTIONS AND APPROVALS FROM BOTH GOVERNMENT AGENCIES AND THE POWER UTILITY. G). REFER TO AV DRAWINGS FOR SCOPE OF WORK ALLOCATION H). PROVIDE GANG BOXES AND PLATES AS PER DIAGRAM. I). ALL SMOKE DETECTORS TO BE HARDWIRED. J). NO ALUMINUM WIRING PERMITTED. K). PROVIDE PIGTAILS AT ALL JUNCTION BOXES INDICATED ON DRAWINGS. INCLUDE INSTALLATION OF FIXTURES PROVIDED BY OWNER AT THOSE LOCATIONS. L). UNLESS OTHERWISE NOTED, LOCATE ALL CEILING BOXES ON THE CENTER LINE OF THE ROOM IN 2 DIRECTIONS AND LOCATE ALL WALL BOXES ON THE CENTER OF THAT WALL. CONFIRM LOCATION OF ALL BOXES WITH ARCHITECT. M). MOUNT ALL SWITCHES AT 4'-0" ABOVE FINISHED FLOOR AND RECEPTACLES IN BASEBOARD (UNLESS OTHERWISE NOTED. FEEDERS AND CIRCUITS: A). PROVIDE ANY AND ALL MATERIALS, EQUIPMENT. LABOR, ETC... NECESSARY FOR THE COMPLETE INSTALLATION OF ALL BRANCH CIRCUITS TO EQUIPMENT, RECEPTACLES AND LIGHTING OUTLETS, AND WIRING FOR CONTROL EQUIPMENT FURNISHED BY OTHERS, ETC... B). WHERE REQUIRED, FURNISH AND INSTALL SAFETY TYPE DISCONNECT SWITCHES, FUSED OR UNFUSED, WITH PROPER POLES AND NEUTRALS, AS EACH CASE REQUIRED, IF THE EQUIVALENT IS NOT EXISTING OR FURNISHED BY OTHERS, AND IS NECESSARY TO CONFORM TO CODE. C). PROVIDE MATCHING RECEPTACLES FOR ALL EQUIPMENT FURNISHED WITH CORD AND PLUG. D). MAKE DIRECT CONNECTIONS AS REQUIRED TO ALL EQUIPMENT NOT FURNISHED WITH CORD AND PLUG. CONDUITS: A). APARTMENT PANEL FEEDER SHALL BE HEAVY-WEIGHT, RIGID, GALVANIZED TYPE. B). GREENFIELD AND THINWALL TUBING MAY BE USED IN HUNG CEILING AND PARTITIONS AS PERMITTED BY CODE AND LABOR AGREEMENTS. C). NO EXPOSED CIRCUITING. DEMOLITION: A). DO ALL NECESSARY DEMOLITION AND REMOVAL OF EXISTING LIGHTING AND ELECTRICAL EQUIPMENT AS REQUIRED. B). REROUTE AND RECONNECT ALL CIRCUITING TO EXISTING LOADS WHICH ARE TO REMAIN IF SAME IS DISTURBED BY DEMOLITION WORK. PROVIDE NEW HOMERUNS, IF REQUIRED. C). CONDUITS COMING UP OUT OF FLOOR SLAB WHICH ARE TO BE REMOVED SHALL BE CUT BACK BELOW TOP OF FINISHED SLAB TO PERMIT PATCHING. D). DISCONNECT AND REMOVE ALL EXISTING WIRING AND EXPOSED CONDUITS NOT BEING RETAINED OR REUSED. E). INSTALL BLANK PLATES ON ALL EXISTING OUTLETS WHICH ARE TO REMAIN BUT HAVE NO DEVICES. F).PROVIDE EXTENSION COLLARS ON EXISTING OUTLETS WHERE EXISTING WALLS, COLUMNS, ETC... ARE BEING LAMINATED OR FURRED-OUT. G). RELOCATE EXISTING ACTIVE OUTLET BOXES, JUNCTION BOXES, ETC... WHICH ARE RENDERED INACCESSIBLE BY NEW CONSTRUCTION. TEMPORARY LIGHT AND POWER: A). POWER SHALL BE OBTAINED FROM THE EXISTING APARTMENT PANEL FEEDER. B). PROVIDE NECESSARY MATERIALS AND LABOR TO MAKE POWER CONNECTIONS FOR MACHINES, PORTABLE TOOLS, ETC... AS USED BY OTHER TRADES, REGARDLESS OF SIZE. C). FURNISH ALL LABOR NEEDED TO KEEP THIS TEMPORARY SYSTEM ENERGIZED DURING THE ENTIRE STANDARD PERIOD OF WORKING TIME OF ALL TRADES, PLUS 15 MINUTES BEFORE AND 15 MINUTES AFTER THIS TIME AND OVERTIME AS REQUIRED FOR ANY AND ALL TRADES. NEW LIGHTING AND APPLIANCE PANEL: A). FURNISH AND INSTALL LIGHTING AND APPLIANCE PANEL AS INDICATED ON PLANS, OF THE CIRCUIT BREAKER TYPE, CONSTRUCTED FOR A ONE (1) PHASE, THREE (3) WIRE, SOLID NEUTRAL, 120/208 VOLT SYSTEM. B). TIE-BARS SHALL NOT BE USED TO CREATE MULTI-POLE CIRCUITS. C). ONLY ONE WIRE SHALL BE INSTALLED UNDER EACH CIRCUIT BREAKER. D). PANELBOARD SHALL BE MOUNTED IN CODE GAUGE AND SIZE BOX(ES) FOR MOUNTING AS INDICATED ON PLANS, COMPLETE WITH TRIM AND DOOR. E). BRANCHES SHALL BE SINGLE POLE CIRCUIT BREAKERS IN GENERAL, AND SHALL BE 15 AMPERE FOR RECEPTACLE AND LIGHTING, 20 AMPERE FOR RECEPTACLES, AND OTHER SIZES AS NOTED ON PLANS. F). INSTALL ACCURATE DIRECTORY INSIDE PANEL DOOR. CATV / TELEPHONE SERVICE: A). PROVIDE ALL POWER SUPPLY OUTLETS AS NOTED AND REQUIRED BY THE TELEPHONE COMPANY FOR USE WITH ITS EQUIPMENT. B). PROVIDE ALL BUSHINGS ON EACH END OF TELEPHONE CONDUITS. C). EXACT EXTENT OF WORK REQUIRED SHALL BE DETERMINED FROM THE TELEPHONE COMPANY REPRESENTATIVE PRIOR TO COMMENCING WORK. D). ELECTRICAL WORK TO INCLUDE IN-WALL TELEPHONE AND CATV WIRING FROM THE UTILITY ENTRY TO APARTMENT TO ALL OUTLETS. WALL JACKS TO BE LEVITON TYPE 625 AND 406 81. WALL TELEPHONE OUTLET TO BE TYPE 630. ALL TELEPHONE LOCATIONS TO HAVE ACCESS TO 4 LINES. E). ALL CATV AND TELEPHONE OUTLETS TO HAVE HOMERUNS TO PANEL AT LOCATION INDICATED.
ELECTRICAL SPECIFICATIONS
3" LED Low-Profile Fixed Downlight.
WP
WP 3" LED Low-Profile Fixed Waterproof Downlight.
GFI
WP
GFI GFI
Nava Companies 31 Union Square West, Suite 2D New York, NY 10003, USA Tel: 212.365.1052 www.navacompanies.com Mechanical Engineer:
WP
3" LED Low-Profile Adjustable Downlight.
WP
Specialty Fixture To Be Determined: Locate on Site With Architect
D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
TV Wall Sconce To Be Determined: Locate on Site with Architect
Structural Engineer: Fixture Switched to Door
STD
Smoke/CO Detector, Hardwired, BRK Brands SC7010B Existing or Proposed Ceiling Clear Height. Coordinate with Elevations
Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
Key Plan:
Static Pressure Vent
S
TV
LUTRON: STWD-5BRL, Color and Engraving TBD
GFI Closet Light, iO Line .75 Undercabinet Light, iO Line .75
1
FOURTH FLOOR REFLECTED CEILING PLAN & POWER PLAN Scale: 1/4" = 1'0"
Legend:
ADDITIONAL NOTES 1 Locate Specialty Fixtures and Sconces On-Site with Architect as Shown. 2. Maximize Clear Ceiling Height Where Possible. Consult with Architect After Demolition.
POWER/ELEC. LEGEND WIRE SYM GFI
GFI
PLAN DESCRIPTION SYM
GFI
TV
Television Outlet, Install at 57"
GFI
Duplex Ground Fault Interupt Convenience Outlet, 15 amp
Notification: COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
Issue Description
Date
ISSUE Duplex Convenience Outlet, 15 amp Quad Convenience Outlet
ROOF TERRACE
OPEN TO BELOW
DCTD
Dedicated Duplex Appliance Outlet (consult appliance schedule and manufacturer for electrical specifications)
S
Switched Duplex Outlet
S
1/2 Switched Duplex Outlet
SHD
Motorized Shade Power
TEL
TEL
Telephone Distribution Point
HUB
NET
Computer Network Distribution Point
DBI
DBI
Door Box Intercom
Date
Revision
TSTAT TSTAT Thermostat Locations Telephone DN
Cable Wall Mounted Phone Floor Telephone
NOTES ROOF REFLECTED CEILING PLAN & POWER PLAN 2 Scale: 1/4" = 1'0"
GROUNDING:
A). WHERE EXISTING WIRING WHICH IS TO REMAIN IS LEFT EXPOSED BY THE DEMOLITION AND REMOVAL OF PARTITIONS AND/OR HUNG CEILINGS, REROUTE SUCH WIRING AS REQUIRED TO MAINTAIN THE CIRCUIT CONTINUITY. 1. GROUNDING CONNECTIONS SHALL BE MADE TO THE NON-CONDUCTIVE CARRYING PARTS OF ALL ELECTRICAL EQUIPMENT AS B). WHERE EXISTING WIRING WHICH IS TO REMAIN IS LEFT STUBBED UP FROM FLOOR BY THE DEMOLITION AND REMOVAL OF NOTE: REQUIRED. PARTITIONS RE-ROUTE SUCH WIRING AS REQUIRED TO MAINTAIN CIRCUIT CONTINUITY AND CUT BACK CONDUIT BELOW TOP OF 1. SHOP DRAWINGS FOR ALL LIGHTING AND LOW VOLTAGE CONTROL SYSTEMS TO BE SUBMITTED TO THE ARCHITECT FOR REVIEW. ELECTRICAL SERVICE: FINISHED SLAB TO PERMIT PATCHING. MATERIALS: 1. EXISTING BUILDING INCOMING ELECTRIC SERVICE SHALL BE UTILIZED FOR THIS WORK. C). WHERE EXISTING CIRCUITING IS BEING UTILIZED FOR CONNECTION OF NEW LOAD OR IS BEING RETAINED FOR EXISTING LOADS 1. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND IN GOOD CONDITION AND HAVE UNDERWRITER'S LABORATORIES LABELS. 2. MAKE ALL NECESSARY MODIFICATIONS, EXTENSIONS, ETC... AS NOTED ON PLANS AND/OR REQUIRED. AND SUCH CIRCUITING IS NOT EXACTLY AS INDICATED ON PLANS, MAKE SUCH MODIFICATIONS AS MAY BE REQUIRED TO WIRING TO 2. ANY MATERIALS AND/OR EQUIPMENT WHICH THE DESIGNER AND ARCHITECT REGARDS AS UNSATISFACTORY SHALL NOT BE INSTALLED; OTHER MATERIALS 3. ENTIRE INSTALLATION SHALL BE IN FULL ACCORDANCE WITH ALL REQUIREMENTS OF THE CONSOLIDATED EDISON COMPANY AND ACCOMPLISH THE DESIGN INTENT. OR EQUIPMENT SHALL BE SUBMITTED AND IF CONSIDERED NECESSARY TO REQUEST PARTICULAR ITEMS BY NAME AND/OR CATALOG NUMBER, SUCH THE SHERRY NETHRTLAND. D). WHERE EXISTING LIGHTING, EQUIPMENT, WIRING, ETC... IS INDICATED AS REMAINING AND SUCH ITEMS INTERFERE WITH THE REQUESTS SHALL BE COMPLIED WITH, WITHOUT ADDITIONAL CHARGE. CONDUCTORS: INSTALLATION OR DEMOLITION WORK OF OTHER TRADES, BUT WILL NOT CONFLICT WITH SAME AFTER WORK IS COMPLETED, 3. MATERIALS AND EQUIPMENT SHALL BE SPECIFIED IN OTHER PARAGRAPHS NOTED ON PLANS, OR SUBJECT TO APPROVAL, BASED UPON ADAPTABILITY FOR 1. ALL BRANCH CIRCUIT CONDUCTORS MAY BE TYPE TW FOR FIFTEEN AND TWENTY AMPERE CIRCUITS. ALL SIZES INDICATED ON DISCONNECT, REMOVE, RELOCATE TO AVOID CONFLICTS, REINSTALL AND RECONNECT SUCH ITEMS AS REQUIRED. INTENDED USE. PLANS ARE BASED UPON THW COPPER WIRE. E). WHERE EXISTING LIGHTING, EQUIPMENT, WIRING, ETC... IS TO REMAIN AND SUCH WIRING IS FOUND TO BE DEFECTIVE, MAKE ALL WORKMANSHIP: 2. ALL CONDUCTORS #8 AND SMALLER SHALL BE SOLID, #6 AND LARGER SHALL BE STRANDED. CORRECTIONS AND REPLACEMENTS NECESSARY TO ELIMINATE THE DEFECT AND PUT SUCH ITEMS IN SATISFACTORY OPERATING 1. INSTALL CONDUITS CAREFULLY AND PROTECT AGAINST DAMAGE, REMOVING ALL CRUSHED OR DAMAGED CONDUITS. CAP OR PLUG ENDS TO PROTECT PIPE SLEEVES, SUPPORTS AND INSERTS: CONDITION. AGAINST DIRT OR MOISTURE BEFORE PULLING WIRES. 1. WHERE PIPES PASS THROUGH MASONRY, CONCRETE WALLS OR FLOORS, SET SUCH SLEEVES AS ARE NECESSARY FOR THE CUTTING AND PATCHING: 2. ALL CONDUITS SHALL BE SUPPORTED WITH APPROPRIATE HANGERS AT NOT OVER 8 FOOT INTERVALS. RUN EXPOSED CONDUITS PARALLEL OR PASSAGE OF THE PIPES. A). DO ALL THE REQUIRED CUTTING OF THE STRUCTURE NECESSARY FOR THE INSTALLATION OF THIS WORK. NO CUTTING LIKELY TO PERPENDICULAR TO WALLS. USE APPROPRIATE FITTINGS FOR ALL BENDS, ETC... 2. SLEEVES SHALL NOT BE USED IN ANY PORTION OF THE BUILDING WHERE THE USE OF SAME WOULD IMPAIR THE STRENGTH OF WEAKEN THE STRUCTURE (OR ANY PART THEREOF) SHALL BE DONE WITHOUT THE WRITTEN APPROVAL OF THE OWNER. 3. PROVIDE ALL LOCKNUTS AND BUSHINGS AS REQUIRED WHERE CONDUITS ENTER BOXES, CABINETS, ETC... CONSTRUCTION FEATURES OF THE BUILDING. B). PATCHING SHALL BE DONE BY THE GENERAL CONTRACTOR. 4. NOT MORE THAN THREE RIGHT-ANGLE BENDS, OR THEIR EQUIVALENT, SHALL BE MADE IN CONDUIT BETWEEN PULLBOXES. 3. SLEEVES PASSING THROUGH WALLS WHERE SUBJECT TO LEAKAGE SHALL BE CAULKED TO OBTAIN A WATER-TIGHT JOINT. 5. LEAVE A DRAG WIRE IN EVERY SPARE OR EMPTY CONDUIT. 6. NOTHING SHALL BE DONE WHICH WILL IN ANY MANNER ENDANGER OR UNDERMINE THE STRUCTURE OR ANY PART THEREOF.
JOB CONDITIONS:
1) All wires should be terminated in a box mounted straight and level at each location unless otherwise noted. 2) All wires are run from their marked location to the main equipment area unless otherwise noted. 3) All wires must be labeled on both ends using the same room names. 4) All power for TV and equipment locations to be on the same phase and within 18" of the wiring point. 5) Do not run any wire parallel to or within 3ft of line voltage electrical power runs. The longer the run, the greater the signal degredation. 6) Cross power lines at 90 degrees whenever possible. 7) All electrical boxes must be minimum 3" deep. All 1-gang boxes should be 1900 box with single gang collar. All Volume Controls (VC) will use mud rings in place of Electrical Boxes. 8) All associated low voltage wire to be supplied by Innovative Audio unless otherwise noted. 9) Avoid running low voltage wire within 10 ft. of high voltage lines, 200 amp feeds, etc. 10) All EQ runs require a 10 ft tail outside of the wall unless otherwise noted. All other locations require a minimum 3 ft tail. 11) See Wire Schedule and GC Scope of Work for more information. 12) Power requirements to be verified by General Contractor
Project Title:
RINKER RESIDENCE 344 E 84TH STREET NEW YORK, NY 10028 Floor Number:
FOURTH FLOOR & ROOF POWER PLAN Seal & Signature:
Date: 5/26/2016 Project Number: Drawing: Checked: Drawing Number:
A-007.00
0440
Architect:
WINDOW SCHEDULE LOCATION
DETAILS
DIMENSION (V.I.F)
WINDOW NUMBER
ROOM
RM #
1
LIVING
201
Existing
2
LIVING
201
Existing
HINGING
HEIGHT
WIDTH
Painted
Existing
5' 7" (E)
3' 2" (E)
Painted
Existing
5' 7" (E)
3' 2" (E)
Painted
Existing
5' 7" (E)
3' 2" (E)
EXT. FINISH INT. FINISH
Existing
HARDWARE
TYPE
REMARKS
SPEC.
Nava Companies 31 Union Square West, Suite 2D New York, NY 10003, USA Tel: 212.365.1052 www.navacompanies.com
3
LIVING
201
4
DINING
202
Painted
Fixed
8'-1 3/8"
2'-6"
Hope's Landmark175 Series
5
DINING
202
Painted
Swing
8'-1 3/8"
2'-6"
Hope's Landmark175 Series
6
DINING
202
Painted
Swing
8'-1 3/8"
2'-6"
Hope's Landmark175 Series
7
KITCHEN
203
Painted
Fixed
5' 1 1/2"
4' 2 1/4"
Hope's Landmark175 Series
8
BEDROOM 1
301
Existing
Painted
Existing
4' 11" (E)
3' 2" (E)
9
BEDROOM 1
301
Existing
Painted
Existing
4' 11" (E)
3' 2" (E)
10
BATHROOM 1
302
Existing
Painted
Existing
4' 11" (E)
3' 2" (E)
11
OWEN'S BEDROOM
305
Existing
Painted
Existing
4' 11" (E)
3' 2" (E)
12
OWEN'S BEDROOM
305
Existing
Painted
Existing
4' 11" (E)
3' 2" (E)
13
OWEN'S BATHROOM
306
Existing
Painted
Existing
4' 11" (E)
3' 2" (E)
14
MASTER BATHROOM
403
Painted
Hopper
5'-7 7/8"
2'-4"
15
MASTER BATHROOM
403
Painted
Hopper
5'-7 7/8"
2'-4"
16
MASTER BEDROOM
401
Painted
Hopper
6'-3 3/8"
2'-8"
17
MASTER BEDROOM
401
Painted
Hopper
6'-3 3/8"
2'-8"
18
MASTER BEDROOM
401
Painted
Hopper
6'-3 3/8"
2'-8"
19
MASTER BEDROOM
401
Painted
Hopper
6'-3 3/8"
2'-8"
20
OFFICE
404
Painted
Fixed
9'-3 1/4"
21
OFFICE
404
Painted
Fixed
22
OFFICE
404
Painted
23
OFFICE
404
24
Mechanical Engineer: D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
Structural Engineer: Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970 (E) AC LOUVER
Key Plan:
(E) AC LOUVER
Legend:
3'-4"
Hope's Landmark175 Series
9'-3 1/4"
3'-4"
Hope's Landmark175 Series
Fixed
9'-3 1/4"
3'-4"
Hope's Landmark175 Series
Painted
Fixed
9'-3 1/4"
3'-4"
Hope's Landmark175 Series
ROOF
Painted
Fixed
6'-3"
3'-9 1/4"
25
ROOF
Painted
Fixed
6'-3"
2'-3 1/8"
26
ROOF
Painted
Fixed
6'-3"
2'-3 1/8"
27
ROOF
Painted
Fixed
6'-3"
2'-3 1/8"
28
ROOF
Painted
Fixed
6'-3"
2'-3 1/8"
Notification: COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
Issue Description ISSUE
1 29
ROOF
Painted
Fixed
6'-3"
2'-3 1/8"
30
ROOF
Painted
Fixed
6'-3"
3'-9 1/4"
Date
NORTH ELEVATION Scale: 3/8" = 1'0"
Date
Revision
NATURAL LIGHT AND VENTILATION
LOCATION Living Room Dining Room
ROOM # 201
SQUARE FT. 270
WINDOW AREA 52.8
Kitchen Bedroom 1
202 203 301
153 100 128.5
120.2 21.5 30
Owen's Bed
305
131.4
Master Bed Master Office
401 404
150 211
30 91.4 135
LIGHT 19% 80% 21.5% 23% 22% 60% 63%
OPR. AREA 26.4 61.4 10.75 15 15
VENT 9.5% 40%
45.7
10.75 % 12.5 % 11% 30%
45
21%
Project Title:
RINKER RESIDENCE 344 E 84TH STREET NEW YORK, NY 10028 Floor Number:
SCHEDULE AND ELEVATION Seal & Signature:
Date: 5/26/2016 Project Number: Drawing: Checked: Drawing Number:
A-008.00
2
SOUTH ELEVATION Scale: 3/8" = 1'0"
0440
Architect:
APPLIANCE SCHEDULE: All appliances to be furnished by Contractor. Contractor to coordinate delivery from sidewalk to apartment and protect items for install.
# 01 02 03 04 05 06 07 08 09
LOCATION Kitchen Kitchen Kitchen Kitchen Kitchen W/D W/D Terrace Office
ROOM # 201 201 201 201 201 303 303
ITEM Refrigerator Range
MFR Miele Miele
Hood Microwave Dishwasher Washer Dryer
Miele Miele Miele LG LG
MODEL # KR 1913 VI HR 1934 DF DAR 1130 H 6700 BM G 6365 SC Vi WM3570HWA DLEX3570W
N/A 404
Outdoor Range
WOLF GE
OG 42 ZDB1240HII
Refrig. Drawers
STYLE Integrated 36" Gas 36" Insert 24" Speed oven Diamond Series WHITE WHITE MONOGRAM
QTY 1 1 1 1 1 1 1 1 1
FINISH SCHEDULE
REMARKS Left Hinge, Integrated
Fully Integrated
TAG F.1
DESCRIPTION LV WOOD - EUROPEAN OAK - ESOPUS - CHARACTER GRADE, WIRE BRUSHED, 7IN PLANK WIDTH
LOCATION
ROOM #
ITEM
STONE SLAB: IMPERIAL WHITE DANBY, HONED - AVAILABLE FROM STONE SOURCE (212) 979.6400
SUBMIT SPEC FOR APPROVAL
F.3
STONE SLAB: STATUARIO TUCCI, HONED, 2" THK. - AVAILABLE FROM STONE SOURCE (212) 979.6400
SUBMIT SPEC FOR APPROVAL
Nava Companies 31 Union Square West, Suite 2D New York, NY 10003, USA Tel: 212.365.1052 www.navacompanies.com Mechanical Engineer:
F.4
STONE DECKING: HONED BASALT
SUBMIT SPEC FOR APPROVAL
D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
F.5
PORCELANOSA KRION SOLID SURFACE MATERIAL. SNOW WHITE. FOR CONSTRUCTION DETAILS AND SUBSTRATE SPECIFICATION SEE CONSTRUCTION DOCUMENTS AND DETAILS
SUBMIT SPEC FOR APPROVAL
Structural Engineer:
F.6
STONE TILE: 12" X 24" CARRARA MARBLE. - AVAILABLE FROM STONE SOURCE (212) 979.6400
SUBMIT SPEC FOR APPROVAL
Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
F.7
TILE: WHITE SUBWAY TILE
SUBMIT SPEC FOR APPROVAL
Key Plan:
24" Integrated
F.8
TILE: ANN SACKS SAVOY PENNY ROUND - PAPERWHITE - USE BLACK GROUT (12" by 12" SAMPLE WITH GROUT TO BE PROVIDED FOR APPROVAL)
SUBMIT SPEC FOR APPROVAL
F.9
TILE: ALLOW $20 PSF
SUBMIT SPEC FOR APPROVAL
F.10
TILE: ALLOW $20 PSF
SUBMIT SPEC FOR APPROVAL
F.11
WOOD: SATIN LACQUER FINISH - COLOR: FARROW & BALL HAGUE BLUE - FINISH SAMPLE TO BE PROVIDED FOR APPROVAL
SUBMIT SPEC FOR APPROVAL
Back Outlet Toilet
F.12
WOOD: SATIN LACQUER FINISH - COLOR: WHITE - FINISH SAMPLE TO BE PROVIDED FOR APPROVAL
SUBMIT SPEC FOR APPROVAL
F.13
WOOD: FINISH TO MATCH SAMPLE OF FINISH F.1 (WOOD FLOOR) - SAMPLE TO BE PROVIDED FOR APPROVAL
SUBMIT SPEC FOR APPROVAL
MFR
MODEL #
STYLE
FINISH
QTY
REMARKS
01
Kitchen
203
Faucet
Newport Brass
9911L
East Linear
Antique Brass
1
3-hole Faucet with Side Spray
02
Kitchen
203
Sink
Franke
MHK110-28
Manor
Fireclay White
1
Apron Front
03
Powder Room
204
Faucet
Hansgrohe
32070821
Talis S
Brushed Nickel
1
Single Lever
04
Powder Room
204
Sink
Duravit
045450
Vero
White
1
Include metal Console #003065
05
Powder Room
204
Toilet
Duravit
213409
Happy D.2
White
1
Back Outlet Toilet
06
Powder Room
204
Toilet Seat
Duravit
0064690099
Happy D.2
White
1
07
Guest Bath
302
Faucet
Hansgrohe
32070821
Talis S
Brushed Nickel
1
08
Guest Bath
302
Toilet
Duravit
213409
Happy D.2
White
1
09
Guest Bath
302
Toilet Seat
Duravit
0064690099
Happy D.2
White
1
10
Guest Bath
302
Sink
Duravit
045748
Happy D.2
White
1
Undermount
11
Guest Bath
302
Showerset
Hansgrohe
27143821
Croma
Brushed Nickel
1
Showerset w/ Tub Spout
12
Guest Bath
302
Tub
Duravit
700100
D-Code
White
1
13
Owen's Bath
306
Toilet
Duravit
213409
Happy D.2
White
1
14
Owen's Bath
306
Toilet Seat
Duravit
0064690099
Happy D.2
White
1
15
Owen's Bath
306
Sink
Duravit
045748
Happy D.2
White
1
16
Owen's Bath
306
Faucet
Hansgrohe
32070821
Talis S
Brushed Nickel
1
17
Owen's Bath
306
Showerset
Hansgrohe
27169821
Croma
Brushed Nickel
1
18
Owen's Bath
306
Showerdrain
Infinity Drain
G3 Square
Satin Stainless
1
19
Master Bath
403
Faucet
Newport Brass
3-9911L
Antique Brass
2
Wall Mounted
20
Master Bath
403
Sink
Custom
2
Provide Drain to Match Faucet
21
Master Bath
403
Toilet
Duravit
212101
Happy D.2
White
1
22
Master Bath
403
Toilet Seat
Duravit
0064690099
Happy D.2
White
23
Master Bath
403
Bathtub
Victoria & Albert
EDG-N-SW
EDGE
Matte White
1 1
24
Master Bath
403
Tub Spout
Newport Brass
3-995L
East Linear
Antique Brass
1
Wall Mounted
25
Master Bath
403
Shower Drain
Infinity Drain
S-AS 99
Satin Stainless
1
Site Sizeable
26
Master Bath
403
Shower Set
Newport Brass
3-1504BP
East Linear
Antique Brass
2
27
Master Bath
403
Hand Shower
Newport Brass
280H
East Linear
Antique Brass
2
28
Office
404
Faucet
Newport Brass
1500-5223
East Linear
Antique Brass
1
29
Office
404
Sink
Franke
CCK110-15
Cisterna
Fireclay White
1
East Linear
SUBMIT SPEC FOR APPROVAL
F.2
PLUMBING FIXTURE SCHEDULE: All plumbing fixtures to be provided by architect
#
NOTES
F.14
WOOD: WEATHERED CEDAR
SUBMIT SPEC FOR APPROVAL
F.15
WOOD: RECLAIMED
SUBMIT SPEC FOR APPROVAL
F.16
METAL: ANTIQUE BRONZE, SUBMIT SAMPLE FOR APPROVAL
SUBMIT SPEC FOR APPROVAL
Back Outlet Toilet Undermount
Include East Liner Handle/Diverter
F.17
METAL: BLACK IRON OR PAINTED STEEL
SUBMIT SPEC FOR APPROVAL
F.18
1
SUBMIT SPEC FOR APPROVAL
4"
CLEAR SILVERED MIRROR - TEMPERED
Legend:
Notification: COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
Issue Description
Date
ISSUE
GENERAL NOTES 1. Contractor to provide paint samples for review and approval for each room and selected colors prior to painting. All painting to be Level-4 paint finish. Assume Benjamin Moore paint for all areas. 2. Where noted, provide Shop Lacquer finish. Contractor to provide paint samples for review and approval. 3. Tile and Stone slabs are contractor furnished and install. Contractor to review slab selection with architect for review and approval.
Date
Revision
Undermount
Project Title:
RINKER RESIDENCE 344 E 84TH STREET NEW YORK, NY 10028 Floor Number:
SCHEDULES Seal & Signature:
Date: 5/26/2016 Project Number: Drawing: Checked: Drawing Number:
A-009.00
0440
Architect:
DOOR SCHEDULE LOCATION
DOOR PROPERTIES
DOOR NUMBER
ROOM
RM #
TYPE
OPENING SIZE
200
ENTRY
200
--
2'-10" X 7'-6"
THK. MATERIAL 1-3/4"
HINGING FINISH
H.M.
DOOR FRAME MATERIAL
LHR
FINISH
TYPE
LOCKSET
DECORATIVE MOULDING
REMARKS
HARDWARE DOOR STOP
SOLID WOOD CASING
ENTRY 3 4"
201 202
MECH. CLOSET
200 201
2'-6" X 7'-6" 2'- 10" X 7'-6"
1-3/4" 1-3/4"
H.M.
RHR
H.M.
PRIVACY
LH
Nava Companies
FIRE RATED PLYWOOD
31 Union Square West, Suite 2D New York, NY 10003, USA
TYPICAL RATED WALL ASSEMBLY
PASSAGE
Tel: 212.365.1052 www.navacompanies.com
203
POWDER ROOM
204
2'- 10" X 7'-6"
1-3/4"
H.M.
RHR
PRIVACY
301
BEDROOM 1
301
3'-0" X 8'-0"
1-3/4"
H.M.
SLIDE
PRIVACY
302
BATHROOM 1
302
2'-10" X 7'-6"
1-3/4"
H.M.
RHR
PRIVACY
304
LOUNGE
304
10'-0" X 8'-0"
1-3/4"
H.M.
SWNG/ SLIDE
PASSAGE
305
OWEN'S BEDROOM
305
2'-10" X 8'-0"
1-3/4"
H.M.
SLIDE
PRIVACY
TRACK: HAFELE HAWA JUNIOR
306
OWEN'S BATHROOM
306
2'-10" X 8'-0"
1-3/4"
H.M.
SLIDE
PRIVACY
TRACK: HAFELE HAWA JUNIOR
401
MASTER BEDROOM
401
3'-0" X 8'-0"
1-3/4"
H.M.
SLIDE
PRIVACY
TRACK: HAFELE HAWA JUNIOR
402
WALK IN CLOSET
402
3'-0" X 8'-0"
1-3/4"
H.M.
SLIDE
PRIVACY
TRACK: HAFELE HAWA JUNIOR
DECORATIVE MOULDING
403
MASTER BATHROOM
403
2'-10" X 8'-0"
1-3/4"
H.M.
SLIDE
PRIVACY
TRACK: HAFELE HAWA JUNIOR
SOLID WOOD CASING
404
OFFICE
404
5'-0" X 8'-0"
1-3/4"
H.M.
SLIDE
PASSAGE
TRACK: HAFELE HAWA JUNIOR
405
OFFICE
404
2'-10" X 8'-0"
1-3/4"
H.M.
RHR
PASSAGE
Mechanical Engineer:
TRACK: HAFELE HAWA JUNIOR
D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284 STONE SADDLE
Structural Engineer:
5
DOOR PLAN DETAIL - INSWING TYPICAL Scale: 3" = 1'0"
Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
Key Plan:
3 4"
FIRE RATED PLYWOOD TYPICAL RATED WALL ASSEMBLY
NOTE: POCKET DOOR DIMENSIONS GIVEN ARE FOR CLEAR OPENINGS. ACTUAL DOOR WIDTH TO EXTEND 1" BEYOND CLEAR OPENING (CONTRACTOR TO VERIFY DIMENSIONS IN FIELD) * MODIFY HEAD/JAMB DETAIL FOR FLUSH CONDITION WITH STONE/TILE/GLASS ** EXTEND JAMB AT INTERIOR TO PROVIDE FLUSH CONDITION WITH FINISH STONE/GLASS
Legend:
BLOCKING AS REQUIRED
Notification:
SLIDING DOOR TRACK CORNER BEAD
6
COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
DOOR PLAN DETAIL - ENTRY Scale: 3" = 1'0"
BLOCKING AS REQUIRED 1 3 4" SOLID CORE DOOR
SOLID WOOD CASING 1 8" THK MASONITE, PAINTED BLACK
SOLID WOOD CASING DECORATIVE MOULDING
11
SOLID WOOD CASING
2"
Issue Description
Date
ISSUE
3 4"
FIRE RATED PLYWOOD
3"
4" FIRE RATED PLYWOOD
318"
3
1 34" SOLID CORE DOOR
318"
23 8"
2"
FIRE RATED PLYWOOD
ALIGN
3 4"
1 3 4" SOLID CORE DOOR
112"
STONE SADDLE OR TYPICAL FLOOR ASSEMBLY
STONE SADDLE OR TYPICAL FLOOR ASSEMBLY
DECORATIVE MOULDING
7
DOOR PLAN DETAIL - 2ND FLOOR Scale: 3" = 1'0" SOLID WOOD CASING
SOLID WOOD CASING
DOOR HEADER DETAIL - INSWING TYPICAL 1 Scale: 3" = 1'0"
Date
Revision
DOOR HEADER DETAIL - SLIDING TYPICAL 2 Scale: 3" = 1'0"
3 4"
FIRE RATED PLYWOOD
112"
3
Project Title:
4" FIRE RATED PLYWOOD
RINKER RESIDENCE
3"
3"
TYPICAL WALL CONSTRUCTION
344 E 84TH STREET NEW YORK, NY 10028
3 4"
1 SOLID CORE DOOR FRY REGLET 'F' REVEAL
TYPICAL WALL ASSEMBLY BASE MOULDING
TYPICAL WALL ASSEMBLY
5 8"
4" 1
23 4"
318"
THK BASEBOARD, FINISHED TO MATCH FLOOR
ORIGINAL FLOOR, REFINISHED
NEW FLOOR, 3 4" ENGINEERED WOOD
Floor Number:
23 8"
1 4"
2"
TYPICAL WALL ASSEMBLY
DOOR DETAILS
112"
Seal & Signature: 1 8"
THK MASONITE, PAINTED BLACK
3 4"
PLYWOOD SUBFLOOR
Date: 5/26/2016 Project Number: Drawing: Checked: Drawing Number:
A-010.00 8 3
BASEBOARD DETAIL - 2ND & 3RD FLOORS Scale: 3" = 1'0"
4
BASEBOARD DETAIL - 4TH FLOOR Scale: 3" = 1'0"
DOOR PLAN DETAIL - 2ND FLOOR Scale: 3" = 1'0"
9
DOOR PLAN DETAIL - 2ND FLR TERRACE Scale: 3" = 1'0"
0440
Architect: CABINET
SOLID WOOD CASING
SOLID WOOD CASING
STONE/TILE 1 8"
THK MASONITE, PAINTED BLACK SOLID WOOD CASING
3 4"
FIRE RATED PLYWOOD
SOLID WOOD CASING
3 4"
THK MASONITE, PAINTED BLACK
FIRE RATED PLYWOOD
SOLID WOOD CASING
23 8"
1 8"
1 8"
THK MASONITE, PAINTED BLACK
23 8"
1 34" SOLID CORE DOOR
1 34" SOLID CORE DOOR
312"
23 8"
23 8"
2"
1
8"
23 8"
3 4"
31 Union Square West, Suite 2D New York, NY 10003, USA
2"
Tel: 212.365.1052 www.navacompanies.com Mechanical Engineer:
23 8"
1 SOLID CORE DOOR
23 8"
23 8"
112"
112"
112"
CABINET DOOR
23 8"
CABINET DOOR
2"
CABINET EDGE
Nava Companies
112"
D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
112"
Structural Engineer:
SOLID WOOD CASING
1 34" SOLID CORE DOOR
4
SOLID WOOD CASING
3
8"
4" FIRE RATED PLYWOOD
312"
TYPICAL WALL CONSTRUCTION
THK MASONITE, PAINTED BLACK
23 8"
2"
112"
112"
1 8"
23 8"
2"
23 8"
FRY REGLET 41" Z REVEAL
112"
2"
112"
8"
23
DOOR PLAN DETAIL Scale: 3" = 1'0"
Key Plan: SOLID WOOD CASING
23
Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
FRY REGLET 41" Z REVEAL
SOLID WOOD CASING
STONE/TILE
FIRE RATED PLYWOOD
1
4"
21
214"
4"
1
SOLID WOOD CASING
4"
3 4"
17 8"
3 4"
FIRE RATED PLYWOOD
318"
Legend:
23 4"
23 4"
Notification:
1
DOOR PLAN DETAIL Scale: 3" = 1'0"
2
DOOR PLAN DETAIL Scale: 3" = 1'0"
3
COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
DOOR PLAN DETAIL Scale: 3" = 1'0"
5
DOOR PLAN DETAIL Scale: 3" = 1'0"
Issue Description
Date
ISSUE
HARDWARE SCHEDULE LOCATION DOOR ID 200 201 202 203 301 302 304 305 306 401 402 403 404 405
ROOM
HINGE SET / SLIDE TRACK MAKER
QTY FINISH
SPEC
KNOB/LEVER/OTHER MAKER
ITEM
QTY SPEC
FINISH: Inside/Outside
PRIVACY/PASSAGE LOCK SET MAKER
SPEC QTY FINISH
1
ENTRY MECH.
Satin Nickel
2
CLOSET
Rixson
F 117
1
Satin Nickel
1
POWDER RM
Rixson
F 117
1
Satin Nickel
1
BEDROOM 1
Hafele
HAWA JUNIOR 250/A
See Details
Halliday Baillie
HB-690
1
Brushed Nickel
BATHROOM 1 LOUNGE OWENS BEDROOM
Hafele
HAWA JUNIOR 250/A
See Details
Halliday Baillie
HB-690
1
Brushed Nickel
OWENS BATHROOM
Hafele
HAWA JUNIOR 250/A
See Details
Halliday Baillie
HB-690
1
Brushed Nickel
MASTER BEDROOM
Hafele
HAWA JUNIOR 250/A
See Details
Halliday Baillie
HB-690
1
Brushed Nickel
WALK IN CLOSET
Hafele
HAWA JUNIOR 250/A
See Details
Halliday Baillie
HB-690
1
Brushed Nickel
MASTER BATH
Hafele
HAWA JUNIOR 250/A
See Details
Halliday Baillie
HB-690
1
Brushed Nickel
OFFICE
Hafele
HAWA JUNIOR 250/A
See Details
Halliday Baillie
HB-690
1
Brushed Nickel
OFFICE
Rixson
F 117
MISCELLANEOUS ITEM
MAKER QTY SPEC
Door Stop
H.S.
1
DS - 202
FINISH Brushed Nickel
Date
Revision
1
2
Satin Nickel
Knob
2
Door Stop
H.S.
1
DS - 202
Brushed Nickel
Project Title:
RINKER RESIDENCE 344 E 84TH STREET NEW YORK, NY 10028 Floor Number:
DOOR DETAILS Seal & Signature:
Date: 5/26/2016 Project Number: Drawing: Checked: Drawing Number:
A-011.00 6
DOOR PLAN DETAIL Scale: 3" = 1'0"
0440
Architect:
Nava Companies 31 Union Square West, Suite 2D New York, NY 10003, USA Tel: 212.365.1052 www.navacompanies.com Mechanical Engineer: D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
Structural Engineer: Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
Key Plan:
Legend:
Notification: COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
Issue Description
Date
ISSUE
Date
Revision
1
LONGITUDINAL SECTION Scale: 3/8" = 1'0"
2
CROSS SECTION Scale: 3/8" = 1'0"
Project Title:
RINKER RESIDENCE 344 E 84TH STREET NEW YORK, NY 10028 Floor Number:
SECTIONS Seal & Signature:
Date: 5/26/2016 Project Number: Drawing: Checked: Drawing Number:
A-012.00
0440
Architect:
05
Nava Companies 31 Union Square West, Suite 2D New York, NY 10003, USA
A-013.00
07
05
Tel: 212.365.1052 www.navacompanies.com Mechanical Engineer:
06
03
D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
PT.
PT.
Structural Engineer:
A-013.00
Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
02 Key Plan:
2
ENTRY ELEVATION Scale: 1/2" = 1'0"
3
ENTRY ELEVATION Scale: 1/2" = 1'0"
Legend:
Notification:
ENTRY & POWDER ROOM PLAN Scale: 1/2" = 1'0"
5'-918"
1
WALLPAPER
COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
PROVIDE MEDICINE CABINET WITH 5 ADJ. SHELVES
Issue Description
WALLPAPER
F.7
WALLPAPER
Date
ISSUE
GENERAL MILLWORK NOTES:
NOTES LEGEND:
24
24
F.7
F.7
F.7
3'-6"
01. ALL DRAWERS AND ROLL OUT SHELVES TO HAVE DOVETAIL CONSTRUCTION. SIDE WALL, FRONT AND BACK PANELS TO BE FULLY EDGED WITH SQUARE SECTION SOLID WOOD, THICKNESS TO MATCH PANEL THICKNESS. 02. ALL CABINET DOORS TO BE INSTALLED WITH CLIP TOP BLUMOTION HINGE SYSTEM UNLESS OTHERWISE NOTED 03. ALL DRAWERS AND ROLL-OUT SHELVES TO BE INSTALLED WITH TANDEM PLUS BLUMOTION DRAWER SYSTEM UNLESS OTHERWISE NOTED 04. ALL DRAWER FACES AND CABINET FACES TO HAVE 3/4" THICK SOLID WOOD STILES AND RAILS UNLESS OTHERWISE NOTED. MORTISE AND TENON ASSEMBLY TYPICAL UNLESS OTHERWISE NOTED 05. WHERE EVER PLYWOOD IS INDICATED IN CASEWORK CONSTRUCTION,(INCLUDING BACK BOXES ETC.), MILLWORKER TO FABRICATE WITH BIRCH OR MAPLE VENEER FURNITURE GRADE PLYWOOD OF THE HIGHEST QUALITY, FREE OF CHECKS, SPLITS, SCARS, AND KNOTS. 06. ALL CABINET DOORS WITH LIFT-UP DOOR MOTION TO BE INSTALLED WITH AVENTOS HK-S STAY LIFT SYSTEM BY BLUM. 07. SHOP DRAWINGS TO BE SUBMITTED FOR ALL CASEWORK ITEMS INCLUDING BUT NOT LIMITED TO RADIATOR ENCLOSURES, ACCESS PANELS, CABINETRY, VANITIES, DOORS, JAMBS, HEADERS, SILLS, MEDICINE CABINETS, AND MISC. FABRICATION TO COMMENCE ONLY UPON APPROVAL OF SHOP DRAWINGS BY ARCHITECT. 08. CONTRACTOR TO PROVIDE FINISH SAMPLES FOR ALL WOOD, METAL, GLASS (MIRRORED, EDGE FINISH, ACID/SANDBLASTED). FABRICATION TO COMMENCE ONLY UPON REVIEW AND APPROVAL BY ARCHITECT. 09. ALL BOTTOM CABINETS TO HAVE (2) ROLL OUT SHELVES UNLESS OTHERWISE NOTED 10. ALL NON-CUSTOM DECORATIVE HARDWARE TO BE INSTALLED ONLY, DECORATIVE HARDWARE TO BE FURNISHED BY OWNER. 11. STONE COUNTERTOP FURNISHED AND INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE NECESSARY TEMPLATES FOR BATHROOM VANITIES. 12. SOLID WOOD EDGING, ALL EXPOSED EDGES
F.7
Date
Revision
4
POWDER ROOM ELEVATION Scale: 1/2" = 1'0"
5
POWDER ROOM ELEVATION Scale: 1/2" = 1'0"
6
POWDER ROOM ELEVATION Scale: 1/2" = 1'0"
7
POWDER ROOM ELEVATION Scale: 1/2" = 1'0"
14.
ADJ. SHELVES
15.
1
NEW WINDOW
16.
SLIDING DOOR TRACK
2.
5/8" TYP X GYP BOARD
17.
SHOP LACQUER PAINT FINISH - COLOR TBD
3.
1
PLYWOOD
18.
FINISH ACCESS PANEL WITH 4 BALL CATCHES
RINKER RESIDENCE
4.
3
PLYWOOD
19.
SHADE POCKET WITH MOTORIZED SHADE
5.
BLOCKING AS REQUIRED
20.
RECESSED TELEVISION BRACKET BOX
344 E 84TH STREET NEW YORK, NY 10028
6.
MITER EDGE
21.
CABLE GROMMET
1.
2"
4"
2"
GLASS SHELVES - STARPHIRE GLASS
7.
CORNER BEAD
22.
1
8.
FRY REGLET 14" REVEAL
23.
PROVIDE BLOCKING AT 3'0" FOR FUTURE GRAB BAR
9.
LED STRIP LIGHT. iO Line .75 Symmetric
10.
LED STRIP LIGHT. iO Line 1.5 (SUITABLE FOR WET
TEMPERED GLASS DOOR/PANEL - STARPHIRE
INSTALLATION 24.
PLUMBING FIXTURE, SEE PLUMBING SCHEDULE
Floor Number:
ENTRY & POWDER ROOM
SHEET A-008.00
LOCATIONS) 11.
2"
Project Title:
LED DOWNLIGHT: SEE RCP SHEET A-006.00 FOR
25.
CLEAR SILVERED MIRROR
SPECIFICATION
26.
METAL SURROUND - SEE FINISH SCHEDULE
Seal & Signature:
Date: 5/26/2016 Project Number:
12.
1" HARDWOOD NOSING
Drawing:
13.
ADJ. HANGING ROD
Checked: Drawing Number:
A-013.00
0440
Architect:
Nava Companies
PT.
31 Union Square West, Suite 2D New York, NY 10003, USA Tel: 212.365.1052 www.navacompanies.com Mechanical Engineer:
PT.
OPEN TO DINING
PT.
D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
PT.
Structural Engineer: Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
Key Plan:
1
LIVING ROOM ELEVATION Scale: 1/2" = 1'0"
2
LIVING ROOM ELEVATION Scale: 1/2" = 1'0"
6
LIVING ROOM ELEVATION Scale: 1 1/2" = 1'0"
GENERAL MILLWORK NOTES:
Legend:
01. ALL DRAWERS AND ROLL OUT SHELVES TO HAVE DOVETAIL CONSTRUCTION. SIDE WALL, FRONT AND BACK PANELS TO BE FULLY EDGED WITH SQUARE SECTION SOLID WOOD, THICKNESS TO MATCH PANEL THICKNESS. 02. ALL CABINET DOORS TO BE INSTALLED WITH CLIP TOP BLUMOTION HINGE SYSTEM UNLESS OTHERWISE NOTED 03. ALL DRAWERS AND ROLL-OUT SHELVES TO BE INSTALLED WITH TANDEM PLUS BLUMOTION DRAWER SYSTEM UNLESS OTHERWISE NOTED 04. ALL DRAWER FACES AND CABINET FACES TO HAVE 3/4" THICK SOLID WOOD STILES AND RAILS UNLESS OTHERWISE NOTED. MORTISE AND TENON ASSEMBLY TYPICAL UNLESS OTHERWISE NOTED 05. WHERE EVER PLYWOOD IS INDICATED IN CASEWORK CONSTRUCTION,(INCLUDING BACK BOXES ETC.), MILLWORKER TO FABRICATE WITH BIRCH OR MAPLE VENEER FURNITURE GRADE PLYWOOD OF THE HIGHEST QUALITY, FREE OF CHECKS, SPLITS, SCARS, AND KNOTS. 06. ALL CABINET DOORS WITH LIFT-UP DOOR MOTION TO BE INSTALLED WITH AVENTOS HK-S STAY LIFT SYSTEM BY BLUM. 07. SHOP DRAWINGS TO BE SUBMITTED FOR ALL CASEWORK ITEMS INCLUDING BUT NOT LIMITED TO RADIATOR ENCLOSURES, ACCESS PANELS, CABINETRY, VANITIES, DOORS, JAMBS, HEADERS, SILLS, MEDICINE CABINETS, AND MISC. FABRICATION TO COMMENCE ONLY UPON APPROVAL OF SHOP DRAWINGS BY ARCHITECT. 08. CONTRACTOR TO PROVIDE FINISH SAMPLES FOR ALL WOOD, METAL, GLASS (MIRRORED, EDGE FINISH, ACID/SANDBLASTED). FABRICATION TO COMMENCE ONLY UPON REVIEW AND APPROVAL BY ARCHITECT. 09. ALL BOTTOM CABINETS TO HAVE (2) ROLL OUT SHELVES UNLESS OTHERWISE NOTED 10. ALL NON-CUSTOM DECORATIVE HARDWARE TO BE INSTALLED ONLY, DECORATIVE HARDWARE TO BE FURNISHED BY OWNER. 11. STONE COUNTERTOP FURNISHED AND INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE NECESSARY TEMPLATES FOR BATHROOM VANITIES. 12. SOLID WOOD EDGING, ALL EXPOSED EDGES
Notification: COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
PT.
PT.
Issue Description
Date
ISSUE
03
01
NOTES LEGEND:
A-014.00
02
Date
Revision
04 LIVING ROOM ELEVATION Scale: 1/2" = 1'0"
1.
NEW WINDOW
2.
5/8" TYP X GYP BOARD
3.
1
4.
3
5.
BLOCKING AS REQUIRED
6.
MITER EDGE
7.
CORNER BEAD
8.
FRY REGLET 1 4" REVEAL
9.
LED STRIP LIGHT. iO Line .75 Symmetric
10.
LED STRIP LIGHT. iO Line 1.5 (SUITABLE FOR WET LOCATIONS)
11.
LED DOWNLIGHT: SEE RCP SHEET A-006.00 FOR SPECIFICATION
RINKER RESIDENCE
12.
1" HARDWOOD NOSING
13.
ADJ. HANGING ROD
344 E 84TH STREET NEW YORK, NY 10028
2"
4"
PLYWOOD
PLYWOOD
14.
ADJ. SHELVES
15.
1
16.
SLIDING DOOR TRACK
17.
SHOP LACQUER PAINT FINISH - COLOR TBD
18.
FINISH ACCESS PANEL WITH 4 BALL CATCHES
19.
SHADE POCKET WITH MOTORIZED SHADE
20.
RECESSED TELEVISION BRACKET BOX
21.
CABLE GROMMET
22.
1
23.
PROVIDE BLOCKING AT 3'0" FOR FUTURE GRAB BAR INSTALLATION
24.
PLUMBING FIXTURE, SEE PLUMBING SCHEDULE SHEET A-008.00
25.
CLEAR SILVERED MIRROR
26.
METAL SURROUND - SEE FINISH SCHEDULE
2"
2"
3
UP Project Title:
PT.
Floor Number:
GLASS SHELVES - STARPHIRE GLASS
LIVING ROOM Seal & Signature: 6'-7"
F.11
2'-0"
Date: 5/26/2016
F.11
Project Number:
TEMPERED GLASS DOOR/PANEL - STARPHIRE
Drawing: F.11
LIVING ROOM PLAN 5 Scale: 1/2" = 1'0"
F.11
Checked: Drawing Number:
A-014.00
4
LIVING ROOM ELEVATION Scale: 1/2" = 1'0"
0440
Architect:
Nava Companies 31 Union Square West, Suite 2D New York, NY 10003, USA Tel: 212.365.1052 www.navacompanies.com F.11
PT.
Mechanical Engineer:
OPEN TO KITCHEN
PT.
D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
F.11
F.7
Structural Engineer: Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
F.11 F.11
Key Plan:
EQ.
1
DINING ROOM ELEVATION Scale: 1/2" = 1'0"
2
DINING ROOM ELEVATION Scale: 1/2" = 1'0"
3
DINING ROOM ELEVATION Scale: 1/2" = 1'0"
Legend:
GENERAL MILLWORK NOTES: 01. ALL DRAWERS AND ROLL OUT SHELVES TO HAVE DOVETAIL CONSTRUCTION. SIDE WALL, FRONT AND BACK PANELS TO BE FULLY EDGED WITH SQUARE SECTION SOLID WOOD, THICKNESS TO MATCH PANEL THICKNESS. 02. ALL CABINET DOORS TO BE INSTALLED WITH CLIP TOP BLUMOTION HINGE SYSTEM UNLESS OTHERWISE NOTED 03. ALL DRAWERS AND ROLL-OUT SHELVES TO BE INSTALLED WITH TANDEM PLUS BLUMOTION DRAWER SYSTEM UNLESS OTHERWISE NOTED 04. ALL DRAWER FACES AND CABINET FACES TO HAVE 3/4" THICK SOLID WOOD STILES AND RAILS UNLESS OTHERWISE NOTED. MORTISE AND TENON ASSEMBLY TYPICAL UNLESS OTHERWISE NOTED 05. WHERE EVER PLYWOOD IS INDICATED IN CASEWORK CONSTRUCTION,(INCLUDING BACK BOXES ETC.), MILLWORKER TO FABRICATE WITH BIRCH OR MAPLE VENEER FURNITURE GRADE PLYWOOD OF THE HIGHEST QUALITY, FREE OF CHECKS, SPLITS, SCARS, AND KNOTS. 06. ALL CABINET DOORS WITH LIFT-UP DOOR MOTION TO BE INSTALLED WITH AVENTOS HK-S STAY LIFT SYSTEM BY BLUM. 07. SHOP DRAWINGS TO BE SUBMITTED FOR ALL CASEWORK ITEMS INCLUDING BUT NOT LIMITED TO RADIATOR ENCLOSURES, ACCESS PANELS, CABINETRY, VANITIES, DOORS, JAMBS, HEADERS, SILLS, MEDICINE CABINETS, AND MISC. FABRICATION TO COMMENCE ONLY UPON APPROVAL OF SHOP DRAWINGS BY ARCHITECT. 08. CONTRACTOR TO PROVIDE FINISH SAMPLES FOR ALL WOOD, METAL, GLASS (MIRRORED, EDGE FINISH, ACID/SANDBLASTED). FABRICATION TO COMMENCE ONLY UPON REVIEW AND APPROVAL BY ARCHITECT. 09. ALL BOTTOM CABINETS TO HAVE (2) ROLL OUT SHELVES UNLESS OTHERWISE NOTED 10. ALL NON-CUSTOM DECORATIVE HARDWARE TO BE INSTALLED ONLY, DECORATIVE HARDWARE TO BE FURNISHED BY OWNER. 11. STONE COUNTERTOP FURNISHED AND INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE NECESSARY TEMPLATES FOR BATHROOM VANITIES. 12. SOLID WOOD EDGING, ALL EXPOSED EDGES
Notification: COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
01
Issue Description
Date
ISSUE
A-015.00
03
02
NOTES LEGEND:
Date
Revision
1.
NEW WINDOW
2.
5/8" TYP X GYP BOARD
3.
1
4.
3
5.
BLOCKING AS REQUIRED
6.
MITER EDGE
7.
CORNER BEAD
8.
FRY REGLET 1 4" REVEAL
9.
LED STRIP LIGHT. iO Line .75 Symmetric
10.
LED STRIP LIGHT. iO Line 1.5 (SUITABLE FOR WET LOCATIONS)
11.
LED DOWNLIGHT: SEE RCP SHEET A-006.00 FOR SPECIFICATION
12.
1" HARDWOOD NOSING
RINKER RESIDENCE
13.
ADJ. HANGING ROD
344 E 84TH STREET NEW YORK, NY 10028
2"
4"
PLYWOOD
PLYWOOD
14.
ADJ. SHELVES
15.
1
16.
SLIDING DOOR TRACK
17.
SHOP LACQUER PAINT FINISH - COLOR TBD
18.
FINISH ACCESS PANEL WITH 4 BALL CATCHES
19.
SHADE POCKET WITH MOTORIZED SHADE
20.
RECESSED TELEVISION BRACKET BOX
21.
CABLE GROMMET
22.
1
23.
PROVIDE BLOCKING AT 3'0" FOR FUTURE GRAB BAR INSTALLATION
24.
PLUMBING FIXTURE, SEE PLUMBING SCHEDULE SHEET A-008.00
25.
CLEAR SILVERED MIRROR
26.
METAL SURROUND - SEE FINISH SCHEDULE
2"
2"
4
DINING ROOM PLAN Scale: 1/2" = 1'0" Project Title:
GLASS SHELVES - STARPHIRE GLASS
TEMPERED GLASS DOOR/PANEL - STARPHIRE
Floor Number:
DINING ROOM Seal & Signature:
Date: 5/26/2016 Project Number: Drawing: Checked: Drawing Number:
A-015.00
0440
EXPOSE BRICK TO ASSESS CONDITION ALTERNATE: FINISH F.7
Architect:
EXPOSE BRICK TO ASSESS CONDITION ALTERNATE: FINISH F.7
10 A-016.00
Nava Companies 31 Union Square West, Suite 2D New York, NY 10003, USA 07
Tel: 212.365.1052 www.navacompanies.com
A-016.00
F.11
Mechanical Engineer: D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
F.2
F.11 F.7
F.11
F.11
F.11
F.7
24 F.2
F.2
F.11
F.11
F.11
SPEED OVEN
F.11
Structural Engineer:
DISHWASHER F.11
F.11
08
F.11
F.11
Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
A-016.00
F.11
F.11
F.11
09 A-016.00
Key Plan: 2'-618"
EQ. 06
EQ.
2'-0"
6'-01
A-016.00
PROVIDE HAFELE MAGIC CORNER I PULL OUT
1
EQ.
2'-0"
6'-5"
2"
PROVIDE HAFELE MAGIC CORNER I PULL OUT
KITCHEN ELEVATION Scale: 1/2" = 1'0"
2
KITCHEN ELEVATION Scale: 1/2" = 1'0"
EQ.
2'-9" 3'-1012"
EQ.
EQ. 4'-9"
PROVIDE HAFELE 503.88.991 DOUBLE PULL OUT TRASH
3
KITCHEN ELEVATION Scale: 1/2" = 1'0"
4
GENERAL MILLWORK NOTES:
KITCHEN ELEVATION Scale: 1/2" = 1'0"
FINISH F.15
Legend:
212"
01. ALL DRAWERS AND ROLL OUT SHELVES TO HAVE DOVETAIL CONSTRUCTION. SIDE WALL, FRONT AND BACK PANELS TO BE FULLY EDGED WITH SQUARE SECTION SOLID WOOD, THICKNESS TO MATCH PANEL THICKNESS. 02. ALL CABINET DOORS TO BE INSTALLED WITH CLIP TOP BLUMOTION HINGE SYSTEM UNLESS OTHERWISE NOTED 03. ALL DRAWERS AND ROLL-OUT SHELVES TO BE INSTALLED WITH TANDEM PLUS BLUMOTION DRAWER SYSTEM UNLESS OTHERWISE NOTED 04. ALL DRAWER FACES AND CABINET FACES TO HAVE 3/4" THICK SOLID WOOD STILES AND RAILS UNLESS OTHERWISE NOTED. MORTISE AND TENON ASSEMBLY TYPICAL UNLESS OTHERWISE NOTED 05. WHERE EVER PLYWOOD IS INDICATED IN CASEWORK CONSTRUCTION,(INCLUDING BACK BOXES ETC.), MILLWORKER TO FABRICATE WITH BIRCH OR MAPLE VENEER FURNITURE GRADE PLYWOOD OF THE HIGHEST QUALITY, FREE OF CHECKS, SPLITS, SCARS, AND KNOTS. 06. ALL CABINET DOORS WITH LIFT-UP DOOR MOTION TO BE INSTALLED WITH AVENTOS HK-S STAY LIFT SYSTEM BY BLUM. 07. SHOP DRAWINGS TO BE SUBMITTED FOR ALL CASEWORK ITEMS INCLUDING BUT NOT LIMITED TO RADIATOR ENCLOSURES, ACCESS PANELS, CABINETRY, VANITIES, DOORS, JAMBS, HEADERS, SILLS, MEDICINE CABINETS, AND MISC. FABRICATION TO COMMENCE ONLY UPON APPROVAL OF SHOP DRAWINGS BY ARCHITECT. 08. CONTRACTOR TO PROVIDE FINISH SAMPLES FOR ALL WOOD, METAL, GLASS (MIRRORED, EDGE FINISH, ACID/SANDBLASTED). FABRICATION TO COMMENCE ONLY UPON REVIEW AND APPROVAL BY ARCHITECT. 09. ALL BOTTOM CABINETS TO HAVE (2) ROLL OUT SHELVES UNLESS OTHERWISE NOTED 10. ALL NON-CUSTOM DECORATIVE HARDWARE TO BE INSTALLED ONLY, DECORATIVE HARDWARE TO BE FURNISHED BY OWNER. 11. STONE COUNTERTOP FURNISHED AND INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE NECESSARY TEMPLATES FOR BATHROOM VANITIES. 12. SOLID WOOD EDGING, ALL EXPOSED EDGES
2'-9"
1'-0"
FINISH F.15
3'-81 4"
04
A-016.00
COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
6'-012"
2'-712"
212"
14
2'-0"
Issue Description
03
Date
ISSUE 1'-912"
02 3'-6"
Notification:
09
DW 07
1'-018"
14
01
09
1'-0" 11
07
2'-3"
A-016.00
14
10 SLIDE
47 8"
NOTES LEGEND:
CABINET SECTION Scale: 1 1/2" = 1'0"
07 2.
5/8" TYP X GYP BOARD
3.
1
4.
3
5.
BLOCKING AS REQUIRED
6.
MITER EDGE
7.
CORNER BEAD
8.
FRY REGLET 1 4" REVEAL
9.
LED STRIP LIGHT. iO Line .75 Symmetric
10.
LED STRIP LIGHT. iO Line 1.5 (SUITABLE FOR WET LOCATIONS)
11.
LED DOWNLIGHT: SEE RCP SHEET A-006.00 FOR SPECIFICATION
12.
1" HARDWOOD NOSING
13.
ADJ. HANGING ROD
14.
ADJ. SHELVES
15.
1
16.
SLIDING DOOR TRACK
17.
SHOP LACQUER PAINT FINISH - COLOR TBD
18.
FINISH ACCESS PANEL WITH 4 BALL CATCHES
19.
SHADE POCKET WITH MOTORIZED SHADE
20.
RECESSED TELEVISION BRACKET BOX
21.
CABLE GROMMET
22.
1
23.
PROVIDE BLOCKING AT 3'0" FOR FUTURE GRAB BAR INSTALLATION
24.
PLUMBING FIXTURE, SEE PLUMBING SCHEDULE SHEET A-008.00
25.
CLEAR SILVERED MIRROR
26.
METAL SURROUND - SEE FINISH SCHEDULE
PLYWOOD
5
1118"
PLYWOOD
KITCHEN PLAN Scale: 1/2" = 1'0"
24
8" 07
Project Title:
4"
2" GLASS SHELVES - STARPHIRE GLASS
07
RINKER RESIDENCE 344 E 84TH STREET NEW YORK, NY 10028
07
07
4"
TEMPERED GLASS DOOR/PANEL - STARPHIRE
3'-0"
1'-93 4"
3'-0"
Floor Number:
KITCHEN
CABINET SECTION Scale: 1 1/2" = 1'0"
8
Seal & Signature:
Date: 5/26/2016
4"
11 4"
Project Number:
3
3
Drawing: Checked:
4" 4"
Drawing Number: 3
A-016.00
4"
4"
2"
SLIDE
07
1'-11 4"
4"
Date
Revision
07
7'-012"
2"
SLIDE
07
4"
NEW WINDOW
3
1.
CABINET SECTION 6 Scale: 1 1/2" = 1'0"
7
CABINET SECTION Scale: 1 1/2" = 1'0"
11
CABINET DETAIL Scale: 3" = 1'0"
9
CABINET SECTION Scale: 1 1/2" = 1'0"
0440
Architect:
Nava Companies 31 Union Square West, Suite 2D New York, NY 10003, USA Tel: 212.365.1052 www.navacompanies.com
02 Mechanical Engineer: D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
A-017.00
03 Structural Engineer: 04 A-016
Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
UP
Key Plan:
1
TERRACE PLAN Scale: 1/2" = 1'0"
2
TERRACE ELEVATION Scale: 1/2" = 1'0" Legend:
HANDRAIL DETAIL 4 Scale: 1 1/2" = 1'0"
GENERAL MILLWORK NOTES: 01. ALL DRAWERS AND ROLL OUT SHELVES TO HAVE DOVETAIL CONSTRUCTION. SIDE WALL, FRONT AND BACK PANELS TO BE FULLY EDGED WITH SQUARE SECTION SOLID WOOD, THICKNESS TO MATCH PANEL THICKNESS. 02. ALL CABINET DOORS TO BE INSTALLED WITH CLIP TOP BLUMOTION HINGE SYSTEM UNLESS OTHERWISE NOTED 03. ALL DRAWERS AND ROLL-OUT SHELVES TO BE INSTALLED WITH TANDEM PLUS BLUMOTION DRAWER SYSTEM UNLESS OTHERWISE NOTED 04. ALL DRAWER FACES AND CABINET FACES TO HAVE 3/4" THICK SOLID WOOD STILES AND RAILS UNLESS OTHERWISE NOTED. MORTISE AND TENON ASSEMBLY TYPICAL UNLESS OTHERWISE NOTED 05. WHERE EVER PLYWOOD IS INDICATED IN CASEWORK CONSTRUCTION,(INCLUDING BACK BOXES ETC.), MILLWORKER TO FABRICATE WITH BIRCH OR MAPLE VENEER FURNITURE GRADE PLYWOOD OF THE HIGHEST QUALITY, FREE OF CHECKS, SPLITS, SCARS, AND KNOTS. 06. ALL CABINET DOORS WITH LIFT-UP DOOR MOTION TO BE INSTALLED WITH AVENTOS HK-S STAY LIFT SYSTEM BY BLUM. 07. SHOP DRAWINGS TO BE SUBMITTED FOR ALL CASEWORK ITEMS INCLUDING BUT NOT LIMITED TO RADIATOR ENCLOSURES, ACCESS PANELS, CABINETRY, VANITIES, DOORS, JAMBS, HEADERS, SILLS, MEDICINE CABINETS, AND MISC. FABRICATION TO COMMENCE ONLY UPON APPROVAL OF SHOP DRAWINGS BY ARCHITECT. 08. CONTRACTOR TO PROVIDE FINISH SAMPLES FOR ALL WOOD, METAL, GLASS (MIRRORED, EDGE FINISH, ACID/SANDBLASTED). FABRICATION TO COMMENCE ONLY UPON REVIEW AND APPROVAL BY ARCHITECT. 09. ALL BOTTOM CABINETS TO HAVE (2) ROLL OUT SHELVES UNLESS OTHERWISE NOTED 10. ALL NON-CUSTOM DECORATIVE HARDWARE TO BE INSTALLED ONLY, DECORATIVE HARDWARE TO BE FURNISHED BY OWNER. 11. STONE COUNTERTOP FURNISHED AND INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE NECESSARY TEMPLATES FOR BATHROOM VANITIES. 12. SOLID WOOD EDGING, ALL EXPOSED EDGES
Notification: COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
Issue Description ISSUE
NEW WINDOW
2.
5/8" TYP X GYP BOARD
3.
1
4.
3
5.
BLOCKING AS REQUIRED
6.
MITER EDGE
7.
CORNER BEAD
8.
FRY REGLET 14" REVEAL
9.
LED STRIP LIGHT. iO Line .75 Symmetric
10.
LED STRIP LIGHT. iO Line 1.5 (SUITABLE FOR WET LOCATIONS)
11.
LED DOWNLIGHT: SEE RCP SHEET A-006.00 FOR SPECIFICATION
12.
1" HARDWOOD NOSING
13.
ADJ. HANGING ROD
14.
ADJ. SHELVES
15.
1
16.
SLIDING DOOR TRACK
17.
SHOP LACQUER PAINT FINISH - COLOR TBD
18.
FINISH ACCESS PANEL WITH 4 BALL CATCHES
19.
SHADE POCKET WITH MOTORIZED SHADE
20.
RECESSED TELEVISION BRACKET BOX
21.
CABLE GROMMET
22.
1
23.
PROVIDE BLOCKING AT 3'0" FOR FUTURE GRAB BAR INSTALLATION
24.
PLUMBING FIXTURE, SEE PLUMBING SCHEDULE SHEET A-008.00
25.
CLEAR SILVERED MIRROR
26.
METAL SURROUND - SEE FINISH SCHEDULE
2"
4"
2"
2"
Date
Revision
NOTES LEGEND: 1.
Date
PLYWOOD
PLYWOOD
GLASS SHELVES - STARPHIRE GLASS
TEMPERED GLASS DOOR/PANEL - STARPHIRE
Project Title:
RINKER RESIDENCE 3
TERRACE ELEVATION Scale: 1/2" = 1'0"
344 E 84TH STREET NEW YORK, NY 10028 Floor Number:
TERRACE Seal & Signature:
Date: 5/26/2016 Project Number: Drawing: Checked: Drawing Number:
A-017.00
0440
Architect:
Nava Companies 31 Union Square West, Suite 2D New York, NY 10003, USA Tel: 212.365.1052 www.navacompanies.com Mechanical Engineer: OPEN TO LOUNGE
D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
W/D
Structural Engineer: Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
Key Plan:
1
CORRIDOR 1 ELEVATION Scale: 1/2" = 1'0"
2
CORRIDOR 1 ELEVATION Scale: 1/2" = 1'0"
Legend:
GENERAL MILLWORK NOTES:
20'-81 4"
01. ALL DRAWERS AND ROLL OUT SHELVES TO HAVE DOVETAIL CONSTRUCTION. SIDE WALL, FRONT AND BACK PANELS TO BE FULLY EDGED WITH SQUARE SECTION SOLID WOOD, THICKNESS TO MATCH PANEL THICKNESS. 02. ALL CABINET DOORS TO BE INSTALLED WITH CLIP TOP BLUMOTION HINGE SYSTEM UNLESS OTHERWISE NOTED 03. ALL DRAWERS AND ROLL-OUT SHELVES TO BE INSTALLED WITH TANDEM PLUS BLUMOTION DRAWER SYSTEM UNLESS OTHERWISE NOTED 04. ALL DRAWER FACES AND CABINET FACES TO HAVE 3/4" THICK SOLID WOOD STILES AND RAILS UNLESS OTHERWISE NOTED. MORTISE AND TENON ASSEMBLY TYPICAL UNLESS OTHERWISE NOTED 05. WHERE EVER PLYWOOD IS INDICATED IN CASEWORK CONSTRUCTION,(INCLUDING BACK BOXES ETC.), MILLWORKER TO FABRICATE WITH BIRCH OR MAPLE VENEER FURNITURE GRADE PLYWOOD OF THE HIGHEST QUALITY, FREE OF CHECKS, SPLITS, SCARS, AND KNOTS. 06. ALL CABINET DOORS WITH LIFT-UP DOOR MOTION TO BE INSTALLED WITH AVENTOS HK-S STAY LIFT SYSTEM BY BLUM. 07. SHOP DRAWINGS TO BE SUBMITTED FOR ALL CASEWORK ITEMS INCLUDING BUT NOT LIMITED TO RADIATOR ENCLOSURES, ACCESS PANELS, CABINETRY, VANITIES, DOORS, JAMBS, HEADERS, SILLS, MEDICINE CABINETS, AND MISC. FABRICATION TO COMMENCE ONLY UPON APPROVAL OF SHOP DRAWINGS BY ARCHITECT. 08. CONTRACTOR TO PROVIDE FINISH SAMPLES FOR ALL WOOD, METAL, GLASS (MIRRORED, EDGE FINISH, ACID/SANDBLASTED). FABRICATION TO COMMENCE ONLY UPON REVIEW AND APPROVAL BY ARCHITECT. 09. ALL BOTTOM CABINETS TO HAVE (2) ROLL OUT SHELVES UNLESS OTHERWISE NOTED 10. ALL NON-CUSTOM DECORATIVE HARDWARE TO BE INSTALLED ONLY, DECORATIVE HARDWARE TO BE FURNISHED BY OWNER. 11. STONE COUNTERTOP FURNISHED AND INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE NECESSARY TEMPLATES FOR BATHROOM VANITIES. 12. SOLID WOOD EDGING, ALL EXPOSED EDGES
3'-0"
5"
1'-7"
10'-01 4"
5"
2.
5/8" TYP X GYP BOARD
3.
1
4.
3
5.
BLOCKING AS REQUIRED
6.
MITER EDGE
7.
CORNER BEAD
8.
FRY REGLET 14" REVEAL
9.
LED STRIP LIGHT. iO Line .75 Symmetric
10.
LED STRIP LIGHT. iO Line 1.5 (SUITABLE FOR WET LOCATIONS)
11.
LED DOWNLIGHT: SEE RCP SHEET A-006.00 FOR SPECIFICATION
12.
1" HARDWOOD NOSING
13.
ADJ. HANGING ROD
2"
4"
PLYWOOD
COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
01
A-018.00
Issue Description
02
3
Date
ISSUE
3'-1012" 20'-81 4"
NOTES LEGEND: NEW WINDOW
2'-10"
Notification:
16'-93 4"
1.
2'-5"
Date
Revision
CORRIDOR 1 PLAN Scale: 1/2" = 1'0"
PLYWOOD
Project Title:
RINKER RESIDENCE 344 E 84TH STREET NEW YORK, NY 10028
14.
ADJ. SHELVES
15.
1
16.
SLIDING DOOR TRACK
17.
SHOP LACQUER PAINT FINISH - COLOR TBD
18.
FINISH ACCESS PANEL WITH 4 BALL CATCHES
19.
SHADE POCKET WITH MOTORIZED SHADE
20.
RECESSED TELEVISION BRACKET BOX
21.
CABLE GROMMET
22.
1
23.
PROVIDE BLOCKING AT 3'0" FOR FUTURE GRAB BAR INSTALLATION
Drawing:
24.
PLUMBING FIXTURE, SEE PLUMBING SCHEDULE SHEET A-008.00
Checked:
25.
CLEAR SILVERED MIRROR
Drawing Number:
26.
METAL SURROUND - SEE FINISH SCHEDULE
2"
2"
GLASS SHELVES - STARPHIRE GLASS
TEMPERED GLASS DOOR/PANEL - STARPHIRE
Floor Number:
CORRIDOR 1 Seal & Signature:
Date: 5/26/2016 Project Number:
A-018.00
0440
Architect:
Nava Companies 06 A-018
31 Union Square West, Suite 2D New York, NY 10003, USA Tel: 212.365.1052 www.navacompanies.com Mechanical Engineer:
SLIDE
D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
Structural Engineer: Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
Key Plan:
BEDROOM 1 ELEVATION Scale: 1/2" = 1'0"
1
2
BEDROOM 1 ELEVATION Scale: 1/2" = 1'0"
3
BEDROOM 1 ELEVATION Scale: 1/2" = 1'0"
4
BEDROOM 1 ELEVATION Scale: 1/2" = 1'0"
GENERAL MILLWORK NOTES: Legend:
01. ALL DRAWERS AND ROLL OUT SHELVES TO HAVE DOVETAIL CONSTRUCTION. SIDE WALL, FRONT AND BACK PANELS TO BE FULLY EDGED WITH SQUARE SECTION SOLID WOOD, THICKNESS TO MATCH PANEL THICKNESS. 02. ALL CABINET DOORS TO BE INSTALLED WITH CLIP TOP BLUMOTION HINGE SYSTEM UNLESS OTHERWISE NOTED 03. ALL DRAWERS AND ROLL-OUT SHELVES TO BE INSTALLED WITH TANDEM PLUS BLUMOTION DRAWER SYSTEM UNLESS OTHERWISE NOTED 04. ALL DRAWER FACES AND CABINET FACES TO HAVE 3/4" THICK SOLID WOOD STILES AND RAILS UNLESS OTHERWISE NOTED. MORTISE AND TENON ASSEMBLY TYPICAL UNLESS OTHERWISE NOTED 05. WHERE EVER PLYWOOD IS INDICATED IN CASEWORK CONSTRUCTION,(INCLUDING BACK BOXES ETC.), MILLWORKER TO FABRICATE WITH BIRCH OR MAPLE VENEER FURNITURE GRADE PLYWOOD OF THE HIGHEST QUALITY, FREE OF CHECKS, SPLITS, SCARS, AND KNOTS. 06. ALL CABINET DOORS WITH LIFT-UP DOOR MOTION TO BE INSTALLED WITH AVENTOS HK-S STAY LIFT SYSTEM BY BLUM. 07. SHOP DRAWINGS TO BE SUBMITTED FOR ALL CASEWORK ITEMS INCLUDING BUT NOT LIMITED TO RADIATOR ENCLOSURES, ACCESS PANELS, CABINETRY, VANITIES, DOORS, JAMBS, HEADERS, SILLS, MEDICINE CABINETS, AND MISC. FABRICATION TO COMMENCE ONLY UPON APPROVAL OF SHOP DRAWINGS BY ARCHITECT. 08. CONTRACTOR TO PROVIDE FINISH SAMPLES FOR ALL WOOD, METAL, GLASS (MIRRORED, EDGE FINISH, ACID/SANDBLASTED). FABRICATION TO COMMENCE ONLY UPON REVIEW AND APPROVAL BY ARCHITECT. 09. ALL BOTTOM CABINETS TO HAVE (2) ROLL OUT SHELVES UNLESS OTHERWISE NOTED 10. ALL NON-CUSTOM DECORATIVE HARDWARE TO BE INSTALLED ONLY, DECORATIVE HARDWARE TO BE FURNISHED BY OWNER. 11. STONE COUNTERTOP FURNISHED AND INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE NECESSARY TEMPLATES FOR BATHROOM VANITIES. 12. SOLID WOOD EDGING, ALL EXPOSED EDGES
Notification: COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
01
Issue Description
Date
ISSUE
03
A-019.00
04
02
NOTES LEGEND: 1.
Date
Revision
NEW WINDOW
2.
5/8" TYP X GYP BOARD
3.
1
4.
3
5.
BLOCKING AS REQUIRED
6.
MITER EDGE
7.
CORNER BEAD
8.
FRY REGLET 14" REVEAL
9.
LED STRIP LIGHT. iO Line .75 Symmetric
10.
LED STRIP LIGHT. iO Line 1.5 (SUITABLE FOR WET LOCATIONS)
11.
LED DOWNLIGHT: SEE RCP SHEET A-006.00 FOR SPECIFICATION
12.
1" HARDWOOD NOSING
13.
ADJ. HANGING ROD
RINKER RESIDENCE
14.
ADJ. SHELVES
15.
1
344 E 84TH STREET NEW YORK, NY 10028
16.
SLIDING DOOR TRACK
17.
SHOP LACQUER PAINT FINISH - COLOR TBD
18.
FINISH ACCESS PANEL WITH 4 BALL CATCHES
19.
SHADE POCKET WITH MOTORIZED SHADE
20.
RECESSED TELEVISION BRACKET BOX
2"
PLYWOOD
5
BEDROOM 1 PLAN Scale: 1/2" = 1'0"
Project Title:
GLASS SHELVES - STARPHIRE GLASS
21.
CABLE GROMMET
22.
1
23.
PROVIDE BLOCKING AT 3'0" FOR FUTURE GRAB BAR INSTALLATION
24.
PLUMBING FIXTURE, SEE PLUMBING SCHEDULE SHEET A-008.00
25.
CLEAR SILVERED MIRROR
26.
METAL SURROUND - SEE FINISH SCHEDULE
2"
7'-10"
4"
PLYWOOD
Floor Number:
BEDROOM 1
TEMPERED GLASS DOOR/PANEL - STARPHIRE
Seal & Signature:
Date: 5/26/2016 Project Number: Drawing: Checked:
2'-0"
Drawing Number: 312"
2"
6
MILLWORK DETAIL Scale: 1 1/2" = 1'0"
A-019.00
0440
Architect:
Nava Companies 31 Union Square West, Suite 2D New York, NY 10003, USA
07 A-020.00
PT.
PT.
Tel: 212.365.1052 www.navacompanies.com
22
PT.
PT.
F.18
Mechanical Engineer:
F.9
F.9
D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
F.9
F.9
1'-103 8"
06 F.9 A-020.00
3'-2"
Structural Engineer:
3'-6"
F.9
Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
F.9
2'-6"
Key Plan:
1
BATHROOM 1 ELEVATION Scale: 1/2" = 1'0"
2
BATHROOM 1 ELEVATION Scale: 1/2" = 1'0"
3
BATHROOM 1 ELEVATION Scale: 1/2" = 1'0"
4
BATHROOM 1 ELEVATION Scale: 1/2" = 1'0"
GENERAL MILLWORK NOTES: Legend:
01 06 F.5
F.15
01
03 2"
2'-10"
F.9
27
F.5
06
02
A-020.00
10"
5'-8"
F.5
03
F.15
F.9
03
24
27
F.9
8"
ISSUE
10"
F.15
CEMENT BOARD
F.9
Date
03 2"
3'-512"
5
COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
06
THINSET LATICRETE 9235
Notification:
Issue Description
2"
04
27
LATICRETE 9235
11"
MARINE GRADE PLYWOOD
06 10"
01. ALL DRAWERS AND ROLL OUT SHELVES TO HAVE DOVETAIL CONSTRUCTION. SIDE WALL, FRONT AND BACK PANELS TO BE FULLY EDGED WITH SQUARE SECTION SOLID WOOD, THICKNESS TO MATCH PANEL THICKNESS. 02. ALL CABINET DOORS TO BE INSTALLED WITH CLIP TOP BLUMOTION HINGE SYSTEM UNLESS OTHERWISE NOTED 03. ALL DRAWERS AND ROLL-OUT SHELVES TO BE INSTALLED WITH TANDEM PLUS BLUMOTION DRAWER SYSTEM UNLESS OTHERWISE NOTED 04. ALL DRAWER FACES AND CABINET FACES TO HAVE 3/4" THICK SOLID WOOD STILES AND RAILS UNLESS OTHERWISE NOTED. MORTISE AND TENON ASSEMBLY TYPICAL UNLESS OTHERWISE NOTED 05. WHERE EVER PLYWOOD IS INDICATED IN CASEWORK CONSTRUCTION,(INCLUDING BACK BOXES ETC.), MILLWORKER TO FABRICATE WITH BIRCH OR MAPLE VENEER FURNITURE GRADE PLYWOOD OF THE HIGHEST QUALITY, FREE OF CHECKS, SPLITS, SCARS, AND KNOTS. 06. ALL CABINET DOORS WITH LIFT-UP DOOR MOTION TO BE INSTALLED WITH AVENTOS HK-S STAY LIFT SYSTEM BY BLUM. 07. SHOP DRAWINGS TO BE SUBMITTED FOR ALL CASEWORK ITEMS INCLUDING BUT NOT LIMITED TO RADIATOR ENCLOSURES, ACCESS PANELS, CABINETRY, VANITIES, DOORS, JAMBS, HEADERS, SILLS, MEDICINE CABINETS, AND MISC. FABRICATION TO COMMENCE ONLY UPON APPROVAL OF SHOP DRAWINGS BY ARCHITECT. 08. CONTRACTOR TO PROVIDE FINISH SAMPLES FOR ALL WOOD, METAL, GLASS (MIRRORED, EDGE FINISH, ACID/SANDBLASTED). FABRICATION TO COMMENCE ONLY UPON REVIEW AND APPROVAL BY ARCHITECT. 09. ALL BOTTOM CABINETS TO HAVE (2) ROLL OUT SHELVES UNLESS OTHERWISE NOTED 10. ALL NON-CUSTOM DECORATIVE HARDWARE TO BE INSTALLED ONLY, DECORATIVE HARDWARE TO BE FURNISHED BY OWNER. 11. STONE COUNTERTOP FURNISHED AND INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE NECESSARY TEMPLATES FOR BATHROOM VANITIES. 12. SOLID WOOD EDGING, ALL EXPOSED EDGES
F.15 1'-0" 03
2"
NOTES LEGEND: 2'-83 8"
2'-05 8"
27
3'-0"
Date
Revision
1.
NEW WINDOW
2.
5/8" TYP X GYP BOARD
3.
1
4.
3
5.
BLOCKING AS REQUIRED
6.
MITER EDGE
7.
CORNER BEAD
8.
FRY REGLET 14" REVEAL
9.
LED STRIP LIGHT. iO Line .75 Symmetric
10.
LED STRIP LIGHT. iO Line 1.5 (SUITABLE FOR WET LOCATIONS)
11.
LED DOWNLIGHT: SEE RCP SHEET A-006.00 FOR SPECIFICATION
12.
1" HARDWOOD NOSING
13.
ADJ. HANGING ROD
14.
ADJ. SHELVES
15.
1
16.
SLIDING DOOR TRACK
17.
SHOP LACQUER PAINT FINISH - COLOR TBD
18.
FINISH ACCESS PANEL WITH 4 BALL CATCHES
19.
SHADE POCKET WITH MOTORIZED SHADE
20.
RECESSED TELEVISION BRACKET BOX
21.
CABLE GROMMET
22.
1
23.
PROVIDE BLOCKING AT 3'0" FOR FUTURE GRAB BAR INSTALLATION
Project Number:
24.
PLUMBING FIXTURE, SEE PLUMBING SCHEDULE SHEET A-008.00
Drawing:
25.
CLEAR SILVERED MIRROR
Checked:
26.
METAL SURROUND - SEE FINISH SCHEDULE
Drawing Number:
27.
STEEL ANGLE
2"
4"
2"
2"
PLYWOOD
PLYWOOD
GLASS SHELVES - STARPHIRE GLASS
TEMPERED GLASS DOOR/PANEL - STARPHIRE
5
BATHROOM 1 PLAN Scale: 1/2" = 1'0"
6
TUB DETAIL Scale: 1 1/2" = 1'0"
Project Title:
SHELF DETAIL 7 Scale: 1 1/2" = 1'0"
RINKER RESIDENCE 344 E 84TH STREET NEW YORK, NY 10028 Floor Number:
BATHROOM 1 Seal & Signature:
Date: 5/26/2016
A-020.00
0440
Architect: 26
26
26
26
26
PT.
26
Nava Companies
PT.
05
31 Union Square West, Suite 2D New York, NY 10003, USA
PT.
A-021.00
Tel: 212.365.1052 www.navacompanies.com PT.
Mechanical Engineer: D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
F.12
PT.
06
PT.
PT.
PT.
PT.
A-021.00
07
F.13
F.13
A-021.00
F.13
F.13
F.13
Structural Engineer:
F.13
2'-7"
F.13
EQ.
EQ.
EQ.
EQ.
F.13
Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
EQ.
Key Plan:
08 A-021.00
1
LOUNGE ELEVATION Scale: 1/2" = 1'0"
2
LOUNGE ELEVATION Scale: 1/2" = 1'0"
3
LOUNGE ELEVATION Scale: 1/2" = 1'0"
14'-014"
GENERAL MILLWORK NOTES:
2'-0"
Legend:
26
Notification:
412" 1"
F.13
1'-6"
4'-53 8"
F.13
1'-10"
26
COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
Issue Description ISSUE
26
01
312"
02
A-021.00
03
F.13 14
MILLWORK DETAIL Scale: 1 1/2" = 1'0" 8'-014"
6
5/8" TYP X GYP BOARD
3.
1
4.
3
5.
BLOCKING AS REQUIRED
6.
MITER EDGE
7.
CORNER BEAD
8.
FRY REGLET 1 4" REVEAL
9.
LED STRIP LIGHT. iO Line .75 Symmetric
10.
LED STRIP LIGHT. iO Line 1.5 (SUITABLE FOR WET
2"
4"
PLYWOOD
PLYWOOD
26
4
LOUNGE PLAN Scale: 1/2" = 1'0" F.13
F.13
1"
2.
Project Title: 33 8"
NEW WINDOW
RINKER RESIDENCE
LOCATIONS) 11.
344 E 84TH STREET NEW YORK, NY 10028
LED DOWNLIGHT: SEE RCP SHEET A-006.00 FOR SPECIFICATION
12.
1" HARDWOOD NOSING
13.
ADJ. HANGING ROD
Date
Revision
2'-1"
NOTES LEGEND: 1.
Date
1'-6"
01. ALL DRAWERS AND ROLL OUT SHELVES TO HAVE DOVETAIL CONSTRUCTION. SIDE WALL, FRONT AND BACK PANELS TO BE FULLY EDGED WITH SQUARE SECTION SOLID WOOD, THICKNESS TO MATCH PANEL THICKNESS. 02. ALL CABINET DOORS TO BE INSTALLED WITH CLIP TOP BLUMOTION HINGE SYSTEM UNLESS OTHERWISE NOTED 03. ALL DRAWERS AND ROLL-OUT SHELVES TO BE INSTALLED WITH TANDEM PLUS BLUMOTION DRAWER SYSTEM UNLESS OTHERWISE NOTED 04. ALL DRAWER FACES AND CABINET FACES TO HAVE 3/4" THICK SOLID WOOD STILES AND RAILS UNLESS OTHERWISE NOTED. MORTISE AND TENON ASSEMBLY TYPICAL UNLESS OTHERWISE NOTED 05. WHERE EVER PLYWOOD IS INDICATED IN CASEWORK CONSTRUCTION,(INCLUDING BACK BOXES ETC.), MILLWORKER TO FABRICATE WITH BIRCH OR MAPLE VENEER FURNITURE GRADE PLYWOOD OF THE HIGHEST QUALITY, FREE OF CHECKS, SPLITS, SCARS, AND KNOTS. 06. ALL CABINET DOORS WITH LIFT-UP DOOR MOTION TO BE INSTALLED WITH AVENTOS HK-S STAY LIFT SYSTEM BY BLUM. 07. SHOP DRAWINGS TO BE SUBMITTED FOR ALL CASEWORK ITEMS INCLUDING BUT NOT LIMITED TO RADIATOR ENCLOSURES, ACCESS PANELS, CABINETRY, VANITIES, DOORS, JAMBS, HEADERS, SILLS, MEDICINE CABINETS, AND MISC. FABRICATION TO COMMENCE ONLY UPON APPROVAL OF SHOP DRAWINGS BY ARCHITECT. 08. CONTRACTOR TO PROVIDE FINISH SAMPLES FOR ALL WOOD, METAL, GLASS (MIRRORED, EDGE FINISH, ACID/SANDBLASTED). FABRICATION TO COMMENCE ONLY UPON REVIEW AND APPROVAL BY ARCHITECT. 09. ALL BOTTOM CABINETS TO HAVE (2) ROLL OUT SHELVES UNLESS OTHERWISE NOTED 10. ALL NON-CUSTOM DECORATIVE HARDWARE TO BE INSTALLED ONLY, DECORATIVE HARDWARE TO BE FURNISHED BY OWNER. 11. STONE COUNTERTOP FURNISHED AND INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE NECESSARY TEMPLATES FOR BATHROOM VANITIES. 12. SOLID WOOD EDGING, ALL EXPOSED EDGES
10'-014"
2'-0"
14
Floor Number:
ADJ. SHELVES
15.
1
16.
SLIDING DOOR TRACK
17.
SHOP LACQUER PAINT FINISH - COLOR TBD
18.
FINISH ACCESS PANEL WITH 4 BALL CATCHES
19.
SHADE POCKET WITH MOTORIZED SHADE
Project Number:
20.
RECESSED TELEVISION BRACKET BOX
Drawing:
21.
CABLE GROMMET
Checked:
22.
1
Drawing Number:
23.
PROVIDE BLOCKING AT 3'0" FOR FUTURE GRAB BAR
2'-7"
LOUNGE Seal & Signature:
TEMPERED GLASS DOOR/PANEL - STARPHIRE
312"
2"
F.13
GLASS SHELVES - STARPHIRE GLASS
312"
2"
2'-7"
14.
A-021.00
INSTALLATION 24.
PLUMBING FIXTURE, SEE PLUMBING SCHEDULE SHEET A-008.00
25.
CLEAR SILVERED MIRROR
26.
METAL SURROUND - SEE FINISH SCHEDULE
Date: 5/26/2016
5
MILLWORK DETAIL Scale: 1 1/2" = 1'0"
7
MILLWORK DETAIL Scale: 1 1/2" = 1'0"
8
MILLWORK DETAIL Scale: 1 1/2" = 1'0"
0440
Architect:
Nava Companies 31 Union Square West, Suite 2D New York, NY 10003, USA
06 A-019
Tel: 212.365.1052 www.navacompanies.com Mechanical Engineer:
SLIDE
D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
SLIDE
Structural Engineer: Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
Key Plan:
1
OWEN'S BEDROOM ELEVATION Scale: 1/2" = 1'0"
2
OWEN'S BEDROOM ELEVATION Scale: 1/2" = 1'0"
GENERAL MILLWORK NOTES: 5'-218"
73 8"
OWEN'S BEDROOM ELEVATION Scale: 1/2" = 1'0"
4
OWEN'S BEDROOM ELEVATION Scale: 1/2" = 1'0"
Legend:
11'-6" 5'-812"
Notification:
4'-312"
COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
Issue Description
Date
ISSUE
01
02
4'-23 4"
11'-614"
01. ALL DRAWERS AND ROLL OUT SHELVES TO HAVE DOVETAIL CONSTRUCTION. SIDE WALL, FRONT AND BACK PANELS TO BE FULLY EDGED WITH SQUARE SECTION SOLID WOOD, THICKNESS TO MATCH PANEL THICKNESS. 02. ALL CABINET DOORS TO BE INSTALLED WITH CLIP TOP BLUMOTION HINGE SYSTEM UNLESS OTHERWISE NOTED 03. ALL DRAWERS AND ROLL-OUT SHELVES TO BE INSTALLED WITH TANDEM PLUS BLUMOTION DRAWER SYSTEM UNLESS OTHERWISE NOTED 04. ALL DRAWER FACES AND CABINET FACES TO HAVE 3/4" THICK SOLID WOOD STILES AND RAILS UNLESS OTHERWISE NOTED. MORTISE AND TENON ASSEMBLY TYPICAL UNLESS OTHERWISE NOTED 05. WHERE EVER PLYWOOD IS INDICATED IN CASEWORK CONSTRUCTION,(INCLUDING BACK BOXES ETC.), MILLWORKER TO FABRICATE WITH BIRCH OR MAPLE VENEER FURNITURE GRADE PLYWOOD OF THE HIGHEST QUALITY, FREE OF CHECKS, SPLITS, SCARS, AND KNOTS. 06. ALL CABINET DOORS WITH LIFT-UP DOOR MOTION TO BE INSTALLED WITH AVENTOS HK-S STAY LIFT SYSTEM BY BLUM. 07. SHOP DRAWINGS TO BE SUBMITTED FOR ALL CASEWORK ITEMS INCLUDING BUT NOT LIMITED TO RADIATOR ENCLOSURES, ACCESS PANELS, CABINETRY, VANITIES, DOORS, JAMBS, HEADERS, SILLS, MEDICINE CABINETS, AND MISC. FABRICATION TO COMMENCE ONLY UPON APPROVAL OF SHOP DRAWINGS BY ARCHITECT. 08. CONTRACTOR TO PROVIDE FINISH SAMPLES FOR ALL WOOD, METAL, GLASS (MIRRORED, EDGE FINISH, ACID/SANDBLASTED). FABRICATION TO COMMENCE ONLY UPON REVIEW AND APPROVAL BY ARCHITECT. 09. ALL BOTTOM CABINETS TO HAVE (2) ROLL OUT SHELVES UNLESS OTHERWISE NOTED 10. ALL NON-CUSTOM DECORATIVE HARDWARE TO BE INSTALLED ONLY, DECORATIVE HARDWARE TO BE FURNISHED BY OWNER. 11. STONE COUNTERTOP FURNISHED AND INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE NECESSARY TEMPLATES FOR BATHROOM VANITIES. 12. SOLID WOOD EDGING, ALL EXPOSED EDGES
3
A-022.00
04
03
NOTES LEGEND: NEW WINDOW
2.
5/8" TYP X GYP BOARD
3.
1
4.
3
5.
BLOCKING AS REQUIRED
6.
MITER EDGE
7.
CORNER BEAD
8.
FRY REGLET 1 4" REVEAL
9.
LED STRIP LIGHT. iO Line .75 Symmetric
10.
LED STRIP LIGHT. iO Line 1.5 (SUITABLE FOR WET LOCATIONS)
11.
LED DOWNLIGHT: SEE RCP SHEET A-006.00 FOR SPECIFICATION
12.
1" HARDWOOD NOSING
13.
ADJ. HANGING ROD
2"
4"
PLYWOOD
PLYWOOD
14.
ADJ. SHELVES
15.
1
16.
SLIDING DOOR TRACK
17.
SHOP LACQUER PAINT FINISH - COLOR TBD
18.
FINISH ACCESS PANEL WITH 4 BALL CATCHES
19.
SHADE POCKET WITH MOTORIZED SHADE
20.
RECESSED TELEVISION BRACKET BOX
21.
CABLE GROMMET
22.
1
23.
PROVIDE BLOCKING AT 3'0" FOR FUTURE GRAB BAR INSTALLATION
24.
PLUMBING FIXTURE, SEE PLUMBING SCHEDULE SHEET A-008.00
25.
CLEAR SILVERED MIRROR
26.
METAL SURROUND - SEE FINISH SCHEDULE
2"
2"
3'-0"
1.
Date
Revision
GLASS SHELVES - STARPHIRE GLASS
TEMPERED GLASS DOOR/PANEL - STARPHIRE
2'-10"
6'-0" 11'-6"
2'-8"
Project Title:
RINKER RESIDENCE 5
OWEN'S BEDROOM PLAN Scale: 1/2" = 1'0"
344 E 84TH STREET NEW YORK, NY 10028 Floor Number:
OWEN'S BEDROOM Seal & Signature:
Date: 5/26/2016 Project Number: Drawing: Checked: Drawing Number:
A-022.00
0440
Architect:
Nava Companies
22
PT.
PROVIDE MEDICINE CABINET WITH ADJ. SHELVES
F.18
31 Union Square West, Suite 2D New York, NY 10003, USA
PT.
F.12
Tel: 212.365.1052 www.navacompanies.com
PT.
Mechanical Engineer:
22 08
D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
A-023.00
SLIDE
F.10 F.10
F.10
F.12
F.5
F.12
09
08
F.10
A-023.00
F.12
F.10
A-023.00
Structural Engineer:
F.10
F.12
Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
F.10
Key Plan:
OWEN'S BATHROOM ELEVATION Scale: 1/2" = 1'0"
1
2
OWEN'S BATHROOM ELEVATION Scale: 1/2" = 1'0"
3
OWEN'S BATHROOM SHOWER ELEVATION Scale: 1/2" = 1'0"
4
OWEN'S BATHROOM ELEVATION Scale: 1/2" = 1'0"
5
OWEN'S BATHROOM ELEVATION Scale: 1/2" = 1'0"
GENERAL MILLWORK NOTES: 2'-8"
2'-0"
F.2 114"
3
Legend:
5"
3
4"
4"
4"
1'-8"
F.12
02
A-023.00
05
8"
2'-81
1018"
04
F.12
F.12 F.12
03
Notification: COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
Issue Description
1'-0"
2'-6"
01
4'-2"
Date
ISSUE
A-023.00 4"
3"
01. ALL DRAWERS AND ROLL OUT SHELVES TO HAVE DOVETAIL CONSTRUCTION. SIDE WALL, FRONT AND BACK PANELS TO BE FULLY EDGED WITH SQUARE SECTION SOLID WOOD, THICKNESS TO MATCH PANEL THICKNESS. 02. ALL CABINET DOORS TO BE INSTALLED WITH CLIP TOP BLUMOTION HINGE SYSTEM UNLESS OTHERWISE NOTED 03. ALL DRAWERS AND ROLL-OUT SHELVES TO BE INSTALLED WITH TANDEM PLUS BLUMOTION DRAWER SYSTEM UNLESS OTHERWISE NOTED 04. ALL DRAWER FACES AND CABINET FACES TO HAVE 3/4" THICK SOLID WOOD STILES AND RAILS UNLESS OTHERWISE NOTED. MORTISE AND TENON ASSEMBLY TYPICAL UNLESS OTHERWISE NOTED 05. WHERE EVER PLYWOOD IS INDICATED IN CASEWORK CONSTRUCTION,(INCLUDING BACK BOXES ETC.), MILLWORKER TO FABRICATE WITH BIRCH OR MAPLE VENEER FURNITURE GRADE PLYWOOD OF THE HIGHEST QUALITY, FREE OF CHECKS, SPLITS, SCARS, AND KNOTS. 06. ALL CABINET DOORS WITH LIFT-UP DOOR MOTION TO BE INSTALLED WITH AVENTOS HK-S STAY LIFT SYSTEM BY BLUM. 07. SHOP DRAWINGS TO BE SUBMITTED FOR ALL CASEWORK ITEMS INCLUDING BUT NOT LIMITED TO RADIATOR ENCLOSURES, ACCESS PANELS, CABINETRY, VANITIES, DOORS, JAMBS, HEADERS, SILLS, MEDICINE CABINETS, AND MISC. FABRICATION TO COMMENCE ONLY UPON APPROVAL OF SHOP DRAWINGS BY ARCHITECT. 08. CONTRACTOR TO PROVIDE FINISH SAMPLES FOR ALL WOOD, METAL, GLASS (MIRRORED, EDGE FINISH, ACID/SANDBLASTED). FABRICATION TO COMMENCE ONLY UPON REVIEW AND APPROVAL BY ARCHITECT. 09. ALL BOTTOM CABINETS TO HAVE (2) ROLL OUT SHELVES UNLESS OTHERWISE NOTED 10. ALL NON-CUSTOM DECORATIVE HARDWARE TO BE INSTALLED ONLY, DECORATIVE HARDWARE TO BE FURNISHED BY OWNER. 11. STONE COUNTERTOP FURNISHED AND INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE NECESSARY TEMPLATES FOR BATHROOM VANITIES. 12. SOLID WOOD EDGING, ALL EXPOSED EDGES
14
8
VANITY DETAIL Scale: 1 1/2" = 1'0"
NOTES LEGEND: 1.
NEW WINDOW
2.
5/8" TYP X GYP BOARD
3.
1
4.
3
5.
BLOCKING AS REQUIRED
6.
MITER EDGE
7.
CORNER BEAD
8.
FRY REGLET 14" REVEAL
9.
LED STRIP LIGHT. iO Line .75 Symmetric
10.
LED STRIP LIGHT. iO Line 1.5 (SUITABLE FOR WET LOCATIONS)
11.
LED DOWNLIGHT: SEE RCP SHEET A-006.00 FOR SPECIFICATION
12.
1" HARDWOOD NOSING
13.
ADJ. HANGING ROD
14.
ADJ. SHELVES
15.
1
16.
SLIDING DOOR TRACK
17.
SHOP LACQUER PAINT FINISH - COLOR TBD
18.
FINISH ACCESS PANEL WITH 4 BALL CATCHES
19.
SHADE POCKET WITH MOTORIZED SHADE
20.
RECESSED TELEVISION BRACKET BOX
21.
CABLE GROMMET
22.
1
23.
PROVIDE BLOCKING AT 3'0" FOR FUTURE GRAB BAR INSTALLATION
24.
PLUMBING FIXTURE, SEE PLUMBING SCHEDULE SHEET A-008.00
2"
PLYWOOD
OWEN'S BATHROOM PLAN Scale: 1/2" = 1'0"
112"
6
1'-17 8"
F.2
Project Title:
SLOPE 81" PER 1'0"
RINKER RESIDENCE
F.12
GLASS SHELVES - STARPHIRE GLASS
F.10
PROVIDE HOLES IN SIDE OF HAMPER FOR VENTILATION
1'-8"
2"
3'-0"
2'-35 8"
4"
2'-912"
PLYWOOD
344 E 84TH STREET NEW YORK, NY 10028 Floor Number:
OWEN'S BATHROOM
TEMPERED GLASS DOOR/PANEL - STARPHIRE
25.
CLEAR SILVERED MIRROR
26.
METAL SURROUND - SEE FINISH SCHEDULE
Seal & Signature:
Date: 5/26/2016 Project Number:
05
Drawing: Checked:
3"
2"
Date
Revision
Drawing Number:
F.12
A-023.00 7
MILLWORK DETAIL Scale: 1 1/2" = 1'0"
9
VANITY DETAIL Scale: 1 1/2" = 1'0"
0440
Architect:
Nava Companies 31 Union Square West, Suite 2D New York, NY 10003, USA Tel: 212.365.1052 www.navacompanies.com Mechanical Engineer: D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
Structural Engineer:
05 A-023
Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
Key Plan:
CORRDIOR 2 ELEVATION Scale: 1/2" = 1'0"
1
2
CORRDIOR 2 ELEVATION Scale: 1/2" = 1'0"
3
CORRDIOR 2 ELEVATION Scale: 1/2" = 1'0" Legend:
GENERAL MILLWORK NOTES: 01. ALL DRAWERS AND ROLL OUT SHELVES TO HAVE DOVETAIL CONSTRUCTION. SIDE WALL, FRONT AND BACK PANELS TO BE FULLY EDGED WITH SQUARE SECTION SOLID WOOD, THICKNESS TO MATCH PANEL THICKNESS. 02. ALL CABINET DOORS TO BE INSTALLED WITH CLIP TOP BLUMOTION HINGE SYSTEM UNLESS OTHERWISE NOTED 03. ALL DRAWERS AND ROLL-OUT SHELVES TO BE INSTALLED WITH TANDEM PLUS BLUMOTION DRAWER SYSTEM UNLESS OTHERWISE NOTED 04. ALL DRAWER FACES AND CABINET FACES TO HAVE 3/4" THICK SOLID WOOD STILES AND RAILS UNLESS OTHERWISE NOTED. MORTISE AND TENON ASSEMBLY TYPICAL UNLESS OTHERWISE NOTED 05. WHERE EVER PLYWOOD IS INDICATED IN CASEWORK CONSTRUCTION,(INCLUDING BACK BOXES ETC.), MILLWORKER TO FABRICATE WITH BIRCH OR MAPLE VENEER FURNITURE GRADE PLYWOOD OF THE HIGHEST QUALITY, FREE OF CHECKS, SPLITS, SCARS, AND KNOTS. 06. ALL CABINET DOORS WITH LIFT-UP DOOR MOTION TO BE INSTALLED WITH AVENTOS HK-S STAY LIFT SYSTEM BY BLUM. 07. SHOP DRAWINGS TO BE SUBMITTED FOR ALL CASEWORK ITEMS INCLUDING BUT NOT LIMITED TO RADIATOR ENCLOSURES, ACCESS PANELS, CABINETRY, VANITIES, DOORS, JAMBS, HEADERS, SILLS, MEDICINE CABINETS, AND MISC. FABRICATION TO COMMENCE ONLY UPON APPROVAL OF SHOP DRAWINGS BY ARCHITECT. 08. CONTRACTOR TO PROVIDE FINISH SAMPLES FOR ALL WOOD, METAL, GLASS (MIRRORED, EDGE FINISH, ACID/SANDBLASTED). FABRICATION TO COMMENCE ONLY UPON REVIEW AND APPROVAL BY ARCHITECT. 09. ALL BOTTOM CABINETS TO HAVE (2) ROLL OUT SHELVES UNLESS OTHERWISE NOTED 10. ALL NON-CUSTOM DECORATIVE HARDWARE TO BE INSTALLED ONLY, DECORATIVE HARDWARE TO BE FURNISHED BY OWNER. 11. STONE COUNTERTOP FURNISHED AND INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE NECESSARY TEMPLATES FOR BATHROOM VANITIES. 12. SOLID WOOD EDGING, ALL EXPOSED EDGES
Notification: 13'-3" 3'-0"
618"
COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
1'-77 8"
3'-0"
Issue Description ISSUE
A-023
02
6'-111 4"
03
4'-0"
01
NOTES LEGEND: 1.
Date
Date
Revision
NEW WINDOW
2.
5/8" TYP X GYP BOARD
3.
1
4.
3
5.
BLOCKING AS REQUIRED
6.
MITER EDGE
7.
CORNER BEAD
8.
FRY REGLET 14" REVEAL
9.
LED STRIP LIGHT. iO Line .75 Symmetric
10.
LED STRIP LIGHT. iO Line 1.5 (SUITABLE FOR WET LOCATIONS)
11.
LED DOWNLIGHT: SEE RCP SHEET A-006.00 FOR SPECIFICATION
12.
1" HARDWOOD NOSING
13.
ADJ. HANGING ROD
14.
ADJ. SHELVES
15.
1
16.
SLIDING DOOR TRACK
17.
SHOP LACQUER PAINT FINISH - COLOR TBD
18.
FINISH ACCESS PANEL WITH 4 BALL CATCHES
19.
SHADE POCKET WITH MOTORIZED SHADE
20.
RECESSED TELEVISION BRACKET BOX
21.
CABLE GROMMET
22.
1
23.
PROVIDE BLOCKING AT 3'0" FOR FUTURE GRAB BAR INSTALLATION
24.
PLUMBING FIXTURE, SEE PLUMBING SCHEDULE SHEET A-008.00
25.
CLEAR SILVERED MIRROR
26.
METAL SURROUND - SEE FINISH SCHEDULE
2"
4"
2"
2"
PLYWOOD
PLYWOOD
10'-612" 13'-3"
Project Title:
4
RINKER RESIDENCE
CORRDIOR 2 PLAN Scale: 1/2" = 1'0"
344 E 84TH STREET NEW YORK, NY 10028
GLASS SHELVES - STARPHIRE GLASS
Floor Number:
CORRIDOR 2 Seal & Signature:
Date: 5/26/2016 Project Number:
TEMPERED GLASS DOOR/PANEL - STARPHIRE
3
HANDRAIL DETAIL Scale: 3" = 1'0"
Drawing: Checked: Drawing Number:
A-024.00
0440
Architect:
Nava Companies
06 A-024
31 Union Square West, Suite 2D New York, NY 10003, USA Tel: 212.365.1052 www.navacompanies.com Mechanical Engineer: D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
Structural Engineer: Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
Key Plan:
MASTER BEDROOM ELEVATION Scale: 1/2" = 1'0"
1
2
MASTER BEDROOM ELEVATION Scale: 1/2" = 1'0"
3
MASTER BEDROOM ELEVATION Scale: 1/2" = 1'0"
Legend:
GENERAL MILLWORK NOTES: 01. ALL DRAWERS AND ROLL OUT SHELVES TO HAVE DOVETAIL CONSTRUCTION. SIDE WALL, FRONT AND BACK PANELS TO BE FULLY EDGED WITH SQUARE SECTION SOLID WOOD, THICKNESS TO MATCH PANEL THICKNESS. 02. ALL CABINET DOORS TO BE INSTALLED WITH CLIP TOP BLUMOTION HINGE SYSTEM UNLESS OTHERWISE NOTED 03. ALL DRAWERS AND ROLL-OUT SHELVES TO BE INSTALLED WITH TANDEM PLUS BLUMOTION DRAWER SYSTEM UNLESS OTHERWISE NOTED 04. ALL DRAWER FACES AND CABINET FACES TO HAVE 3/4" THICK SOLID WOOD STILES AND RAILS UNLESS OTHERWISE NOTED. MORTISE AND TENON ASSEMBLY TYPICAL UNLESS OTHERWISE NOTED 05. WHERE EVER PLYWOOD IS INDICATED IN CASEWORK CONSTRUCTION,(INCLUDING BACK BOXES ETC.), MILLWORKER TO FABRICATE WITH BIRCH OR MAPLE VENEER FURNITURE GRADE PLYWOOD OF THE HIGHEST QUALITY, FREE OF CHECKS, SPLITS, SCARS, AND KNOTS. 06. ALL CABINET DOORS WITH LIFT-UP DOOR MOTION TO BE INSTALLED WITH AVENTOS HK-S STAY LIFT SYSTEM BY BLUM. 07. SHOP DRAWINGS TO BE SUBMITTED FOR ALL CASEWORK ITEMS INCLUDING BUT NOT LIMITED TO RADIATOR ENCLOSURES, ACCESS PANELS, CABINETRY, VANITIES, DOORS, JAMBS, HEADERS, SILLS, MEDICINE CABINETS, AND MISC. FABRICATION TO COMMENCE ONLY UPON APPROVAL OF SHOP DRAWINGS BY ARCHITECT. 08. CONTRACTOR TO PROVIDE FINISH SAMPLES FOR ALL WOOD, METAL, GLASS (MIRRORED, EDGE FINISH, ACID/SANDBLASTED). FABRICATION TO COMMENCE ONLY UPON REVIEW AND APPROVAL BY ARCHITECT. 09. ALL BOTTOM CABINETS TO HAVE (2) ROLL OUT SHELVES UNLESS OTHERWISE NOTED 10. ALL NON-CUSTOM DECORATIVE HARDWARE TO BE INSTALLED ONLY, DECORATIVE HARDWARE TO BE FURNISHED BY OWNER. 11. STONE COUNTERTOP FURNISHED AND INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE NECESSARY TEMPLATES FOR BATHROOM VANITIES. 12. SOLID WOOD EDGING, ALL EXPOSED EDGES
Notification:
5'-918"
COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
01
Issue Description
Date
ISSUE
02
A-025.00
04 SLIDE
4'-0"
03
2'-1114"
NOTES LEGEND:
Date
Revision
1.
NEW WINDOW
2.
5/8" TYP X GYP BOARD
3.
1
4.
3
5.
BLOCKING AS REQUIRED
6.
MITER EDGE
7.
CORNER BEAD
8.
FRY REGLET 14" REVEAL
9.
LED STRIP LIGHT. iO Line .75 Symmetric
10.
LED STRIP LIGHT. iO Line 1.5 (SUITABLE FOR WET LOCATIONS)
11.
LED DOWNLIGHT: SEE RCP SHEET A-006.00 FOR SPECIFICATION
12.
1" HARDWOOD NOSING
RINKER RESIDENCE
13.
ADJ. HANGING ROD
14.
ADJ. SHELVES
344 E 84TH STREET NEW YORK, NY 10028
15.
1
16.
SLIDING DOOR TRACK
17.
SHOP LACQUER PAINT FINISH - COLOR TBD
18.
FINISH ACCESS PANEL WITH 4 BALL CATCHES
19.
SHADE POCKET WITH MOTORIZED SHADE
20.
RECESSED TELEVISION BRACKET BOX
2"
4"
2"
PLYWOOD
PLYWOOD
4
5
MASTER BEDROOM PLAN Scale: 1/2" = 1'0"
MASTER BEDROOM ELEVATION Scale: 1/2" = 1'0"
Project Title:
GLASS SHELVES - STARPHIRE GLASS
Floor Number:
MASTER BEDROOM
21.
CABLE GROMMET
22.
1
23.
PROVIDE BLOCKING AT 3'0" FOR FUTURE GRAB BAR INSTALLATION
24.
PLUMBING FIXTURE, SEE PLUMBING SCHEDULE SHEET A-008.00
25.
CLEAR SILVERED MIRROR
Checked:
26.
METAL SURROUND - SEE FINISH SCHEDULE
Drawing Number:
2"
TEMPERED GLASS DOOR/PANEL - STARPHIRE
Seal & Signature:
Date: 5/26/2016 Project Number: Drawing:
A-025.00
0440
Architect:
PT.
PT.
Nava Companies
09
31 Union Square West, Suite 2D New York, NY 10003, USA
A-026.00
10
PT.
F.11
A-026.00
F.11
F.11
F.11
Tel: 212.365.1052 www.navacompanies.com
F.11
Mechanical Engineer:
2'-6"
SLIDE
PT.
PT.
F.7
F.11
D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
F.11
Structural Engineer: 07
06
08
A-026.00
A-026.00
A-026.00
F.11
F.11
F.11
F.11
F.11
3'-0"
PT.
Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
F.11
F.11
Key Plan: 3'-07 8"
2'-0"
1
OFFICE ELEVATION Scale: 1/2" = 1'0"
2
OFFICE ELEVATION Scale: 1/2" = 1'0"
3
2'-0"
OFFICE ELEVATION Scale: 1/2" = 1'0"
GENERAL MILLWORK NOTES: Legend: 4"
NEW WINDOW
2.
5/8" TYP X GYP BOARD
3.
1
4.
3
5.
BLOCKING AS REQUIRED
6.
MITER EDGE
7.
CORNER BEAD
8.
FRY REGLET 14" REVEAL
9.
LED STRIP LIGHT. iO Line .75 Symmetric
10.
LED STRIP LIGHT. iO Line 1.5 (SUITABLE FOR WET LOCATIONS)
11.
LED DOWNLIGHT: SEE RCP SHEET A-006.00 FOR SPECIFICATION
12.
1" HARDWOOD NOSING
13.
ADJ. HANGING ROD
Notification:
1'-9"
PT.
PT.
1'-2"
F.15
F.15
27
F.15 1'-0"
1'-1112"
PT.
212"
2'-115 8"
14
04
09
F.11
F.11
F.11 F.11
27
F.11
1'-0"
01 4'-0"
EQ.
EQ.
4'-0" 1"
15'-03 4"
A-026.00
212"
1'-0"
02
Date
ISSUE 1'-2"
2'-6"
F.11
COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
Issue Description
PT.
03 4
OFFICE ELEVATION Scale: 1/2" = 1'0"
9
MILLWORK DETAIL Scale: 1 1/2" = 1'0"
10
MILLWORK DETAIL Scale: 1 1/2" = 1'0"
Date
Revision
PLYWOOD
PLYWOOD
F.2 4"
27 3
114"
4"
F.15 14
4'-0"
2"
212"
PT.
NOTES LEGEND: 1.
27 1'-0"
3
PT.
10'-112"
01. ALL DRAWERS AND ROLL OUT SHELVES TO HAVE DOVETAIL CONSTRUCTION. SIDE WALL, FRONT AND BACK PANELS TO BE FULLY EDGED WITH SQUARE SECTION SOLID WOOD, THICKNESS TO MATCH PANEL THICKNESS. 02. ALL CABINET DOORS TO BE INSTALLED WITH CLIP TOP BLUMOTION HINGE SYSTEM UNLESS OTHERWISE NOTED 03. ALL DRAWERS AND ROLL-OUT SHELVES TO BE INSTALLED WITH TANDEM PLUS BLUMOTION DRAWER SYSTEM UNLESS OTHERWISE NOTED 04. ALL DRAWER FACES AND CABINET FACES TO HAVE 3/4" THICK SOLID WOOD STILES AND RAILS UNLESS OTHERWISE NOTED. MORTISE AND TENON ASSEMBLY TYPICAL UNLESS OTHERWISE NOTED 05. WHERE EVER PLYWOOD IS INDICATED IN CASEWORK CONSTRUCTION,(INCLUDING BACK BOXES ETC.), MILLWORKER TO FABRICATE WITH BIRCH OR MAPLE VENEER FURNITURE GRADE PLYWOOD OF THE HIGHEST QUALITY, FREE OF CHECKS, SPLITS, SCARS, AND KNOTS. 06. ALL CABINET DOORS WITH LIFT-UP DOOR MOTION TO BE INSTALLED WITH AVENTOS HK-S STAY LIFT SYSTEM BY BLUM. 07. SHOP DRAWINGS TO BE SUBMITTED FOR ALL CASEWORK ITEMS INCLUDING BUT NOT LIMITED TO RADIATOR ENCLOSURES, ACCESS PANELS, CABINETRY, VANITIES, DOORS, JAMBS, HEADERS, SILLS, MEDICINE CABINETS, AND MISC. FABRICATION TO COMMENCE ONLY UPON APPROVAL OF SHOP DRAWINGS BY ARCHITECT. 08. CONTRACTOR TO PROVIDE FINISH SAMPLES FOR ALL WOOD, METAL, GLASS (MIRRORED, EDGE FINISH, ACID/SANDBLASTED). FABRICATION TO COMMENCE ONLY UPON REVIEW AND APPROVAL BY ARCHITECT. 09. ALL BOTTOM CABINETS TO HAVE (2) ROLL OUT SHELVES UNLESS OTHERWISE NOTED 10. ALL NON-CUSTOM DECORATIVE HARDWARE TO BE INSTALLED ONLY, DECORATIVE HARDWARE TO BE FURNISHED BY OWNER. 11. STONE COUNTERTOP FURNISHED AND INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE NECESSARY TEMPLATES FOR BATHROOM VANITIES. 12. SOLID WOOD EDGING, ALL EXPOSED EDGES
19.
SHADE POCKET WITH MOTORIZED SHADE
20.
RECESSED TELEVISION BRACKET BOX
21.
CABLE GROMMET
22.
1
23.
PROVIDE BLOCKING AT 3'0" FOR FUTURE GRAB BAR INSTALLATION
24.
PLUMBING FIXTURE, SEE PLUMBING SCHEDULE SHEET A-008.00
25.
CLEAR SILVERED MIRROR
26.
METAL SURROUND - SEE FINISH SCHEDULE
27.
STEEL ANGLE
1"
1"
43 4"
14
Floor Number:
18
TEMPERED GLASS DOOR/PANEL - STARPHIRE
PROVIDE (1) HANGING ROD (3) ADJ. SHELVES
MASTER BEDROOM Seal & Signature:
Date: 5/26/2016 Project Number:
4"
Drawing:
3
OFFICE PLAN 5 Scale: 1/2" = 1'0"
Checked: Drawing Number:
312"
312"
2"
344 E 84TH STREET NEW YORK, NY 10028
1"
FINISH ACCESS PANEL WITH 4 BALL CATCHES
RINKER RESIDENCE
33 8" 1"
18.
Project Title:
718"
SHOP LACQUER PAINT FINISH - COLOR TBD
12
1'-07 8"
17.
33 8"
SLIDING DOOR TRACK
GLASS SHELVES - STARPHIRE GLASS
2'-112"
16.
2"
2'-07 8"
15.
7'-1"
2'-0"
ADJ. SHELVES 1
4'-6"
2'-111 4"
14.
12
A-026.00
6
MILLWORK DETAIL Scale: 1 1/2" = 1'0"
7
MILLWORK DETAIL Scale: 1 1/2" = 1'0"
8
MILLWORK DETAIL Scale: 1 1/2" = 1'0"
0440
Architect:
06
Nava Companies
2'-3"
07
08
PT.
A-027.00
A-027.00
A-027.00
25
31 Union Square West, Suite 2D New York, NY 10003, USA Tel: 212.365.1052 www.navacompanies.com
26
6'-0"
SLIDE
D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
SLIDE
5'-2"
4"
4"
Mechanical Engineer:
PT.
Structural Engineer:
1'-2"
Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
Key Plan: EQ.
EQ.
EQ.
WALK IN CLOSET ELEVATION Scale: 1/2" = 1'0"
WALK IN CLOSET ELEVATION Scale: 1/2" = 1'0"
2
GENERAL MILLWORK NOTES:
PROVIDE (1) HANGING ROD (3) ADJ. SHELVES
01. ALL DRAWERS AND ROLL OUT SHELVES TO HAVE DOVETAIL CONSTRUCTION. SIDE WALL, FRONT AND BACK PANELS TO BE FULLY EDGED WITH SQUARE SECTION SOLID WOOD, THICKNESS TO MATCH PANEL THICKNESS. 02. ALL CABINET DOORS TO BE INSTALLED WITH CLIP TOP BLUMOTION HINGE SYSTEM UNLESS OTHERWISE NOTED 03. ALL DRAWERS AND ROLL-OUT SHELVES TO BE INSTALLED WITH TANDEM PLUS BLUMOTION DRAWER SYSTEM UNLESS OTHERWISE NOTED 04. ALL DRAWER FACES AND CABINET FACES TO HAVE 3/4" THICK SOLID WOOD STILES AND RAILS UNLESS OTHERWISE NOTED. MORTISE AND TENON ASSEMBLY TYPICAL UNLESS OTHERWISE NOTED 05. WHERE EVER PLYWOOD IS INDICATED IN CASEWORK CONSTRUCTION,(INCLUDING BACK BOXES ETC.), MILLWORKER TO FABRICATE WITH BIRCH OR MAPLE VENEER FURNITURE GRADE PLYWOOD OF THE HIGHEST QUALITY, FREE OF CHECKS, SPLITS, SCARS, AND KNOTS. 06. ALL CABINET DOORS WITH LIFT-UP DOOR MOTION TO BE INSTALLED WITH AVENTOS HK-S STAY LIFT SYSTEM BY BLUM. 07. SHOP DRAWINGS TO BE SUBMITTED FOR ALL CASEWORK ITEMS INCLUDING BUT NOT LIMITED TO RADIATOR ENCLOSURES, ACCESS PANELS, CABINETRY, VANITIES, DOORS, JAMBS, HEADERS, SILLS, MEDICINE CABINETS, AND MISC. FABRICATION TO COMMENCE ONLY UPON APPROVAL OF SHOP DRAWINGS BY ARCHITECT. 08. CONTRACTOR TO PROVIDE FINISH SAMPLES FOR ALL WOOD, METAL, GLASS (MIRRORED, EDGE FINISH, ACID/SANDBLASTED). FABRICATION TO COMMENCE ONLY UPON REVIEW AND APPROVAL BY ARCHITECT. 09. ALL BOTTOM CABINETS TO HAVE (2) ROLL OUT SHELVES UNLESS OTHERWISE NOTED 10. ALL NON-CUSTOM DECORATIVE HARDWARE TO BE INSTALLED ONLY, DECORATIVE HARDWARE TO BE FURNISHED BY OWNER. 11. STONE COUNTERTOP FURNISHED AND INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE NECESSARY TEMPLATES FOR BATHROOM VANITIES. 12. SOLID WOOD EDGING, ALL EXPOSED EDGES
3
WALK IN CLOSET ELEVATION Scale: 1/2" = 1'0"
3.
1
4.
3
5.
BLOCKING AS REQUIRED
6.
MITER EDGE
7.
CORNER BEAD
8.
FRY REGLET 1 4" REVEAL
9.
LED STRIP LIGHT. iO Line .75 Symmetric
10.
LED STRIP LIGHT. iO Line 1.5 (SUITABLE FOR WET LOCATIONS)
11.
LED DOWNLIGHT: SEE RCP SHEET A-006.00 FOR SPECIFICATION
12.
1" HARDWOOD NOSING
13.
ADJ. HANGING ROD
14.
ADJ. SHELVES
15.
1
16.
SLIDING DOOR TRACK
17.
SHOP LACQUER PAINT FINISH - COLOR TBD
18.
FINISH ACCESS PANEL WITH 4 BALL CATCHES
19.
SHADE POCKET WITH MOTORIZED SHADE
20.
RECESSED TELEVISION BRACKET BOX
21.
CABLE GROMMET
22.
1
23.
PROVIDE BLOCKING AT 3'0" FOR FUTURE GRAB BAR INSTALLATION
24.
PLUMBING FIXTURE, SEE PLUMBING SCHEDULE SHEET A-008.00
EQ. 2'-23 8"
EQ.
09 A-027.00
14
17
01
Date
ISSUE
7'-2"
A-027.00
02 14
EQ.
04
7'-73 8"
17
1'-5"
2'-07 8" 14 17
Date
Revision 14
PLYWOOD
PLYWOOD
5
7'-07 8"
7'-07 8"
SLIDE
11"
WALK IN CLOSET PLAN Scale: 1/2" = 1'0"
3"
PROVIDE (2) HANGING RODS (1) ADJ. SHELF
SLIDE
57 8"
PROVIDE (1) HANGING ROD (3) ADJ. SHELVES
14
10 A-027.00
6"
SLIDE
SLIDE
Project Title:
RINKER RESIDENCE 344 E 84TH STREET NEW YORK, NY 10028
11"
09
GLASS SHELVES - STARPHIRE GLASS
SLIDE 4" 3
METAL SURROUND - FINISH F.16
Seal & Signature:
4"
2"
03
PULL DETAIL Scale: 3" = 1'0"
6
MILLWORK DETAIL Scale: 1 1/2" = 1'0"
7
MILLWORK DETAIL Scale: 1 1/2" = 1'0"
Drawing: Checked: Drawing Number:
A-027.00
17
10
Date: 5/26/2016 Project Number:
SLIDE
3"
3 1
DRESSING ROOM
112"
CLEAR SILVERED MIRROR
SLIDE
112"
TYPICAL EDGE DETAIL Scale: 3" = 1'0"
9
SLIDE
LINE OF SHELF/DRAWER BEYOND 111 4"
17
Floor Number:
87 8"
3"
11"
09
3"
TEMPERED GLASS DOOR/PANEL - STARPHIRE
17
17
1'-1"
2"
Issue Description
09
03
1"
2"
Notification: COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
13
3"
26.
4"
17
VARIES, SEE PLAN
09
09
118"
25.
2"
LINE OF LED STRIP BEYOND
1'-5"
5/8" TYP X GYP BOARD
Legend:
17
17
1'-113 8"
2.
WALK IN CLOSET ELEVATION Scale: 1/2" = 1'0"
LINE OF LED STRIP BEYOND
17
NOTES LEGEND: NEW WINDOW
4
PROVIDE (2) HANGING RODS (1) ADJ. SHELF
PROVIDE (3) ADJ. SHELVES (4) SLIDES SEE DETAIL 08
09
1.
EQ. 4'-8"
7'-11 4"
7'-73 8"
1
EQ.
EQ.
112"
EQ.
3"
EQ.
8
MILLWORK DETAIL Scale: 1 1/2" = 1'0"
0440
Architect:
PT. F.6
2'-3"
Nava Companies
2'-3"
31 Union Square West, Suite 2D New York, NY 10003, USA Tel: 212.365.1052 www.navacompanies.com F.18
PT.
F.5
Mechanical Engineer:
F.6
8'-0"
F.6
PT.
PT.
4'-0"
F.18
1'-0"
SLIDE
D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
F.6
08 F.6
A-028.00
F.6
12 A-028.00
F.6
F.13
F.13
F.13
F.13
F.13
F.13
F.13
Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
2'-8"
F.13
Structural Engineer:
Key Plan: 112"
EQ.
5'-113 4"
112"
EQ.
112"
4'-03 4"
EQ.
EQ.
112"
4'-03 4" 14 A-028.00
1
MASTER BATH ELEVATION Scale: 1/2" = 1'0"
2
MASTER BATH ELEVATION Scale: 1/2" = 1'0"
3
MASTER BATH ELEVATION Scale: 1/2" = 1'0"
4
MASTER BATHROOM ELEVATION Scale: 1/2" = 1'0" 09
10 A-028.00
Legend:
12 26 4"
112"
09
112"
11
3
4"
118" 1"
1
12 15
5"
EQ.
1
26 4"
Notification:
F.5
1
A-028.00
COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
2"
F.5 EQ.
8"
F.13
112"
12
25
1'-214"
Date
ISSUE
1
612"
63 4"
4"
4"
8"
Issue Description 3
81
15
F.13
3'-10"
EQ.
8'-0"
09
F.5
F.6
1" 5"
3'-47 8" AFF
F.13
26
26
EQ.
F.6
EQ.
9 3'-0"
MASTER BATH ELEVATION 5 Scale: 1/2" = 1'0"
VANITY DETAIL Scale: 1 1/2" = 1'0"
10
SECTION DETAIL Scale: 3" = 1'0"
11
SECTION DETAIL Scale: 3" = 1'0"
F.3
MASTER BATH ELEVATION 7 Scale: 1/2" = 1'0" 24
412" F.6
F.6 4"
10
3 1 SLOPE 8" PER 1'0"
1
F.14
1'-93 8"
2'-0"
6" 1 8"
3'-63 8"
2'-0"
4" 2" 8"
9'-65 8"
114"
612"
2"
112"
1
13 A-028.00
1'-014"
A-028.00
12
24
5"
14
F.13
F.6
Project Title:
RINKER RESIDENCE
95 8"
F.13
SECTION DETAIL 12 Scale: 3" = 1'0"
2'-87 8"
5'-83 8"
01
Date
Revision 1'-03 4"
SECTION DETAIL 13 Scale: 3" = 1'0"
PLAN DETAIL 14 Scale: 3" = 1'0"
344 E 84TH STREET NEW YORK, NY 10028 Floor Number:
05
02
A-028.00
912"
F.13
04 5"
A-028.00 FLOOR FINISH F.8
6
4'-6"
FLOOR FINISH F.8
03
MASTER BATHROOM PLAN Scale: 1/2" = 1'0"
8
3'-0" CLEAR
VANITY DETAIL Scale: 1 1/2" = 1'0"
NOTES LEGEND:
13.
ADJ. HANGING ROD
14.
ADJ. SHELVES
1.
NEW WINDOW
15.
1
2.
5/8" TYP X GYP BOARD
16.
SLIDING DOOR TRACK
3.
1
PLYWOOD
17.
SHOP LACQUER PAINT FINISH - COLOR TBD
4.
3
PLYWOOD
18.
FINISH ACCESS PANEL WITH 4 BALL CATCHES
5.
BLOCKING AS REQUIRED
19.
SHADE POCKET WITH MOTORIZED SHADE
6.
MITER EDGE
20.
RECESSED TELEVISION BRACKET BOX
7.
CORNER BEAD
21.
CABLE GROMMET
8.
FRY REGLET 14" REVEAL
22.
1
9.
LED STRIP LIGHT. iO Line .75 Symmetric
23.
PROVIDE BLOCKING AT 3'0" FOR FUTURE GRAB
10.
LED STRIP LIGHT. iO Line 1.5 (SUITABLE FOR
2"
4"
WET LOCATIONS) 11.
12.
2"
2"
GLASS SHELVES - STARPHIRE GLASS
TEMPERED GLASS DOOR/PANEL - STARPHIRE
BAR INSTALLATION 24.
PLUMBING FIXTURE, SEE PLUMBING SCHEDULE SHEET A-008.00
LED DOWNLIGHT: SEE RCP SHEET A-006.00 FOR SPECIFICATION
25.
CLEAR SILVERED MIRROR
1" HARDWOOD NOSING
26.
METAL SURROUND - FINISH F.16
GENERAL MILLWORK NOTES: 01. ALL DRAWERS AND ROLL OUT SHELVES TO HAVE DOVETAIL CONSTRUCTION. SIDE WALL, FRONT AND BACK PANELS TO BE FULLY EDGED WITH SQUARE SECTION SOLID WOOD, THICKNESS TO MATCH PANEL THICKNESS. 02. ALL CABINET DOORS TO BE INSTALLED WITH CLIP TOP BLUMOTION HINGE SYSTEM UNLESS OTHERWISE NOTED 03. ALL DRAWERS AND ROLL-OUT SHELVES TO BE INSTALLED WITH TANDEM PLUS BLUMOTION DRAWER SYSTEM UNLESS OTHERWISE NOTED 04. ALL DRAWER FACES AND CABINET FACES TO HAVE 3/4" THICK SOLID WOOD STILES AND RAILS UNLESS OTHERWISE NOTED. MORTISE AND TENON ASSEMBLY TYPICAL UNLESS OTHERWISE NOTED 05. WHERE EVER PLYWOOD IS INDICATED IN CASEWORK CONSTRUCTION,(INCLUDING BACK BOXES ETC.), MILLWORKER TO FABRICATE WITH BIRCH OR MAPLE VENEER FURNITURE GRADE PLYWOOD OF THE HIGHEST QUALITY, FREE OF CHECKS, SPLITS, SCARS, AND KNOTS.
06. ALL CABINET DOORS WITH LIFT-UP DOOR MOTION TO BE INSTALLED WITH AVENTOS HK-S STAY LIFT SYSTEM BY BLUM. 07. SHOP DRAWINGS TO BE SUBMITTED FOR ALL CASEWORK ITEMS INCLUDING BUT NOT LIMITED TO RADIATOR ENCLOSURES, ACCESS PANELS, CABINETRY, VANITIES, DOORS, JAMBS, HEADERS, SILLS, MEDICINE CABINETS, AND MISC. FABRICATION TO COMMENCE ONLY UPON APPROVAL OF SHOP DRAWINGS BY ARCHITECT. 08. CONTRACTOR TO PROVIDE FINISH SAMPLES FOR ALL WOOD, METAL, GLASS (MIRRORED, EDGE FINISH, ACID/SANDBLASTED). FABRICATION TO COMMENCE ONLY UPON REVIEW AND APPROVAL BY ARCHITECT. 09. ALL BOTTOM CABINETS TO HAVE (2) ROLL OUT SHELVES UNLESS OTHERWISE NOTED 10. ALL NON-CUSTOM DECORATIVE HARDWARE TO BE INSTALLED ONLY, DECORATIVE HARDWARE TO BE FURNISHED BY OWNER. 11. STONE COUNTERTOP FURNISHED AND INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE NECESSARY TEMPLATES FOR BATHROOM VANITIES. 12. SOLID WOOD EDGING, ALL EXPOSED EDGES
MASTER BATHROOM Seal & Signature:
Date: 5/26/2016 Project Number: Drawing: Checked: Drawing Number:
A-028.00
0440
Architect:
Nava Companies 31 Union Square West, Suite 2D New York, NY 10003, USA Tel: 212.365.1052 www.navacompanies.com Mechanical Engineer: D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
Structural Engineer:
05 A-028
Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
Key Plan:
BALCONY ELEVATION Scale: 1/2" = 1'0"
1
2
BALCONY ELEVATION Scale: 1/2" = 1'0"
3
BALCONY ELEVATION Scale: 1/2" = 1'0"
Legend:
GENERAL MILLWORK NOTES: 01. ALL DRAWERS AND ROLL OUT SHELVES TO HAVE DOVETAIL CONSTRUCTION. SIDE WALL, FRONT AND BACK PANELS TO BE FULLY EDGED WITH SQUARE SECTION SOLID WOOD, THICKNESS TO MATCH PANEL THICKNESS. 02. ALL CABINET DOORS TO BE INSTALLED WITH CLIP TOP BLUMOTION HINGE SYSTEM UNLESS OTHERWISE NOTED 03. ALL DRAWERS AND ROLL-OUT SHELVES TO BE INSTALLED WITH TANDEM PLUS BLUMOTION DRAWER SYSTEM UNLESS OTHERWISE NOTED 04. ALL DRAWER FACES AND CABINET FACES TO HAVE 3/4" THICK SOLID WOOD STILES AND RAILS UNLESS OTHERWISE NOTED. MORTISE AND TENON ASSEMBLY TYPICAL UNLESS OTHERWISE NOTED 05. WHERE EVER PLYWOOD IS INDICATED IN CASEWORK CONSTRUCTION,(INCLUDING BACK BOXES ETC.), MILLWORKER TO FABRICATE WITH BIRCH OR MAPLE VENEER FURNITURE GRADE PLYWOOD OF THE HIGHEST QUALITY, FREE OF CHECKS, SPLITS, SCARS, AND KNOTS. 06. ALL CABINET DOORS WITH LIFT-UP DOOR MOTION TO BE INSTALLED WITH AVENTOS HK-S STAY LIFT SYSTEM BY BLUM. 07. SHOP DRAWINGS TO BE SUBMITTED FOR ALL CASEWORK ITEMS INCLUDING BUT NOT LIMITED TO RADIATOR ENCLOSURES, ACCESS PANELS, CABINETRY, VANITIES, DOORS, JAMBS, HEADERS, SILLS, MEDICINE CABINETS, AND MISC. FABRICATION TO COMMENCE ONLY UPON APPROVAL OF SHOP DRAWINGS BY ARCHITECT. 08. CONTRACTOR TO PROVIDE FINISH SAMPLES FOR ALL WOOD, METAL, GLASS (MIRRORED, EDGE FINISH, ACID/SANDBLASTED). FABRICATION TO COMMENCE ONLY UPON REVIEW AND APPROVAL BY ARCHITECT. 09. ALL BOTTOM CABINETS TO HAVE (2) ROLL OUT SHELVES UNLESS OTHERWISE NOTED 10. ALL NON-CUSTOM DECORATIVE HARDWARE TO BE INSTALLED ONLY, DECORATIVE HARDWARE TO BE FURNISHED BY OWNER. 11. STONE COUNTERTOP FURNISHED AND INSTALLED BY CONTRACTOR. CONTRACTOR TO PROVIDE NECESSARY TEMPLATES FOR BATHROOM VANITIES. 12. SOLID WOOD EDGING, ALL EXPOSED EDGES
Notification:
6'-4"
Issue Description
3'-0"
GFI
03
A-028
2.
5/8" TYP X GYP BOARD
3.
1
4.
3
5.
BLOCKING AS REQUIRED
6.
MITER EDGE
7.
CORNER BEAD
8.
FRY REGLET 14" REVEAL
9.
LED STRIP LIGHT. iO Line .75 Symmetric
10.
LED STRIP LIGHT. iO Line 1.5 (SUITABLE FOR WET LOCATIONS)
11.
LED DOWNLIGHT: SEE RCP SHEET A-006.00 FOR SPECIFICATION
12.
1" HARDWOOD NOSING
13.
ADJ. HANGING ROD
4"
PLYWOOD
ADJ. SHELVES
15.
1
16.
SLIDING DOOR TRACK
17.
SHOP LACQUER PAINT FINISH - COLOR TBD
18.
FINISH ACCESS PANEL WITH 4 BALL CATCHES
19.
SHADE POCKET WITH MOTORIZED SHADE
20.
RECESSED TELEVISION BRACKET BOX
21.
CABLE GROMMET
22.
1
23.
PROVIDE BLOCKING AT 3'0" FOR FUTURE GRAB BAR INSTALLATION
24.
PLUMBING FIXTURE, SEE PLUMBING SCHEDULE SHEET A-008.00
25.
CLEAR SILVERED MIRROR
26.
METAL SURROUND - SEE FINISH SCHEDULE
2"
15'-03 4"
PLYWOOD
14.
2"
Date
Revision
Project Title:
RINKER RESIDENCE
3'-3"
2"
02
4"
01
21'-33
NEW WINDOW
Date
ISSUE
NOTES LEGEND: 1.
COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
344 E 84TH STREET NEW YORK, NY 10028 Floor Number:
GLASS SHELVES - STARPHIRE GLASS
6'-5"
BALCONY Seal & Signature:
Date: 5/26/2016 Project Number:
TEMPERED GLASS DOOR/PANEL - STARPHIRE
Drawing:
4
BALCONY PLAN Scale: 1/2" = 1'0"
Checked: Drawing Number:
A-029.00 5
BALCONY DETAIL Scale: 1" = 1'0"
0440
Architect:
Nava Companies 31 Union Square West, Suite 2D New York, NY 10003, USA Tel: 212.365.1052 www.navacompanies.com Mechanical Engineer: D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284
ROOF TERRACE
Structural Engineer: Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970
OPEN TO BELOW
Key Plan:
DN
1
ROOF PLAN Scale: 1/4" = 1'0" Legend:
Notification: COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.
Issue Description
Date
ISSUE
Date
Revision
2
ROOF ELEVATION Scale: 1/2" = 1'0"
Project Title:
RINKER RESIDENCE 344 E 84TH STREET NEW YORK, NY 10028 Floor Number:
ROOF Seal & Signature:
Date: 5/26/2016 Project Number: Drawing: Checked: Drawing Number:
A-030.00
3
ROOF ELEVATION Scale: 1/2" = 1'0"
0440