Z Port

Page 1

JUSTIN KRAJCI

ARCHITECTURE PORTFOLIO


JUSTIN KRAJCI JSKRAJCI@GMAIL.COM (219) 801-8498 5299 W. 113TH AVE CROWN POINT, IN 46307


TABLE OF CONTENTS

GRESHAM SMITH DESIGN COMPETITION......................................................................2-5 SOLAR DECATHLON..............................................................................................................6-13 NET-ZERO INFILL HOUSING.............................................................................................14-17 LAMINATION + BEND........................................................................................................18-23


GRESHAM SMITH DESIGN COMPETITION 2011



4 The objective of the Gresham Smith Design Competition was to design a community center for downtown Indianapolis that would honor both the memory and the work of the late Julia Carson. In this partner based project, I was responsible for scheduling and task management. I also needed to develop an understanding for the project area and technology that would be required. ruckle st

east 29th st

site location plan

central ave

east 28th st

l fal

y

kw

kp

e cre


5


SOLAR DECATHLON 2013 TEAM KENTUCKIANA



8

SOLAR DECATHLON 2013 ENVELOPE TEAM

1

SOUTH

EAST

NORTH

WEST

2

ELEVATIONS

ELEVATIONS

---

ROOF 17' - 6"

Roof 2 15' - 0"

top of gutter 12' - 0"

CEILING 10' - 2"

gutter detail

FIRST FLOOR 2' - 0"

GRADE 0' - 0"


1

2

9 photovoltaic panel Metal Flashing Metal Roof Waterproof membrane 2” Rigid Polystyrene Insulation

---

TEAM NAME:

Angled cut lumber (infill)

TEAM KENTUCKIANA

ADDRESS:

BALL STATE UNIVERSITY COLLEGE OF ARCHITECTURE AND PLANNING 2000 W. UNIVERSITY AVE. MUNCIE, IN 47306

2x4 6 1/2” SIP panel

ROOF 17' - 6"

UNIVERSITY OF LOUISVILLE LOUISVILLE, KY 40292

corten steel

UNIVERSITY OF KENTUCKY COLLEGE OF ENGINEERING 351 RALPH G. ANDERSON BUILDING LEXINGTON, KY 40506

2” Rigid Polystyrene Insulation CONTACT:

4 1/2” SIP panel

Roof 2 15' - 0"

UOFLSOLARDECATHLON@GMAIL.COM

UNIVERSITIES INVOLVED:

Interior Wood Finish metal flashing gutter (metal and OSB)

top of gutter 12' - 0"

Infill (insulation most likely) photovoltaic panel

LDL beam: 3 x 15 glulam

Metal Flashing

bolted connection to beam

CEILING 10' - 2"

Metal Roof

top of gutter 12' - 0"

PROJECT CLIENT:

Solar Lip Detail 0”

6”

Waterproof membrane

U.S. DEPARTMENT OF ENERGY

2’

1’

2” Rigid Polystyrene 2013 Insulation SOLAR DECATHLON

TEAM NAME:

WWW.SOLARDECATHLON.GOV

Angled cut lumber (infill)

gutter detail

Wood Trellis

TEAM KENTUCKIAN

ADDRESS:

BALL STATE UNIVERSIT COLLEGE OF ARCHITECTURE AND PLANNIN 2000 W. UNIVERSITY AV MUNCIE, IN 4730

2x4 6 1/2” SIP panel

UNIVERSITY OF LOUISVILL LOUISVILLE, KY 4029

corten steel

UNIVERSITY OF KENTUCK COLLEGE OF ENGINEERIN 351 RALPH G. ANDERSON BUILDIN LEXINGTON, KY 4050

2” Rigid Polystyrene Insulation Photovoltaic Panel

CONTACT:

4 1/2” SIP panel

UOFLSOLARDECATHLON@GMAIL.CO

UNIVERSITIES INVOLVED:

corten steel facade

Metal Roof

Interior Wood Finish

2” Rigid Insulation 4 1/2” SIP Panel (OSB, foam, OSB)

6 1/2” SIP panel OSB, Foam, OSB

metal flashing

FIRST FLOOR 2' - 0"

gutter (metal and OSB)

Wood Interior Finish

Infill (insulation most likely)

Sliding protection panel corten, plywood, corten

LDL beam: 3 x 15 glulam

top of gutter 12' - 0"

Gutter Detail 0”

6”

Solar Lip Detail WALL SECTIONS 0”

2’

1’

GRADE 0' - 0"

SHEET TITLE:

bolted connection to beam

6”

U.S. DEPARTMENT OF ENERGY 2013 SOLAR DECATHLON

XXX House 4/19/12 Author Checker

PROJECT NAME:

Wood Trellis

PROJECT CLIENT:

2’

1’ DATE: DRAWN BY: CHECKED BY:

A 1.11

WWW.SOLARDECATHLON.GOV

4/23/2012 12:36:15 AM

2” rigid insulation

Photovoltaic Panel

2

RoofEast Section 3 - Metal Looking 1/2" = 1'-0" 2” rigid insulation 6 1/2” SIP panel OSB, Foam, OSB

corten steel facade 2” Rigid Insulation

DETAILS: GUTTER AND SOLAR LIP

4 1/2” SIP Panel (OSB, foam, OSB) Wood Interior Finish

Sliding protection panel corten, plywood, corten

SHEET TITLE:

Gutter Detail 0”

6”

1’

WALL SECTIONS 2’

XXX Hou 4/19/ Auth Check

PROJECT NAME: DATE: DRAWN BY: CHECKED BY:

A 1.11


SOLAR DECATHLON 2013 EARLY PROPOSAL



12

52'-3" 23'-7"

18'-0" 9'-10 1/2" 8'-1 1/2"

10'-8"

每5'-0"

16'-0"

16'-0"

每3'-6"


Standard semi trailer

58 foot low boy trailer


14

NET-ZERO INFILL HOUSING MUNCIE, INDIANA


15


16 The objective of the Net-Zero Infill House was in a vacant lot in Muncie, Indiana. The project designing a building with a tight envelope. The 20. The project helped develop my knowledge of

COR. METAL ROOF

BUILDING FELT STRUCTURAL INSULATED PANEL INTERIOR DRYWALL STRUCTURAL INSULATED PANEL BUILDING FELT

WOOD VENEER LIGHTSHELF

to design a net-zero house for placement take an in-depth look at the importance of wall was designed with an R-Value of over sustainable design practices, specifically SIPS.


17


18

LAMINATION + BEND SAN FRANCISCO, CA





22 The idea behind Lamination + Bend was to take one material (glulam) and give it an action or movement (bending). This criteria is suppossed to shape the facade, as well as the rest of the design

up