Construction document set - -Renovation

Page 1

CENTER - ALTERATION / RENOVATION

PROJECT NO. SHEET NO. THIS DRAWING IS THE PROPERTY OF BWA Architects, PLLC. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCED OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT A Abbreviations List (Architectural Only) N I D H G V Q P W O U C B F AB ANCHOR BOLT ABV ABOVE ACOUST ACOUSTIC(AL) A/C AIR CONDITIONING(ER) AD AREA DRAIN ADHES ADHESIVE ADJUST ADJUSTABLE AFF ABOVE FINISHED FLOOR AGG AGGREGATE(S) ALUM ALUMINUM ALT ALTERNATE(IVE) ANC ANCHOR ANOD ANODIZE(D) APPROX APPROXIMATE ARCH ARCHITECT(URAL) ASPH ASPHALT(IC) AUTO AUTOMATIC E T M S L K J R X GRAPHICS SYMBOL LEGEND STRUCTURAL/COLUMN REFERENCE GRID PARTITION TYPE DOOR NUMBER/ MARK EQUIPMENT MARK WINDOW TYPE MARK REVISION LEVEL LINE NEW CONTOURS TEST BORING EXISTING CONTOURS EXISTING POINT ELEVATION NEW OR REQUIRED POINT ELEVATION BUILDING SECTION DETAIL WALL SECTION BUILDING ELEVATION 222 0 E3 D1 E3 D2 TB-1 222 0 222.0' 222.0 ISSUE DATE LOCATION MAP INTERIOR ELEVATION DETAIL DIRECTIONAL ROOM/ SPACE NUMBER DETAIL BOOKLET REFERENCE ENLARGED DETAIL DETAIL BOOKLET SECTION REFERENCE W/O ARROW NONDIRECTIONAL AREA MAP BD BOARD BIT BITUMEN BLDG BUILDING BLK BLOCK BLKG BLOCKING BM BEAM B.M. BENCH MARK BOT BOTTOM BRK BRICK BSMT BASEMENT BUR BUILT-UP ROOFING CAB CABINET CC CENTER TO CENTER CF CUBIC FOOT CG CORNER GUARD CHBD CHALKBOARD CI CAST IRON CJ CONTROL JOINT CL CLOSET CLG CEILING CLR CLEAR(ANCE) CMT CERAMIC MOSAIC TILE CMU CONCRETE MASONRY UNIT CFMF COLD FORMED METAL FRAM'G CNTRL CONTROL COL COLUMN CONC CONCRETE CONST CONSTRUCTION CONT CONTINOUOUS COR CORRIDOR CORR CORRUGATED CPT CARPET CRS COURSE COURSING CT CERAMIC TILE CTR CENTER CW COLD WATER CY CUBIC YARD DEMO DEMOLISH DEMOLITION DF DRINKING FOUNTAIN DH DOUBLE HUNG DIA DIAMETER DIAG DIAGONAL DIM DIMENSION DIV DIVISION DL DEAD LOAD DMPR DAMPER DR DOOR DS DOWN SPOUT DTL DETAIL DWG DRAWING(S) DWR DRAWER EA EACH EB EXPANSION BOLT EIFS EXT. INSUL AND FIN SYSTEM EJ EXPANSION JOINT ELEC ELECTRIC(AL) ELEV ELEVATION EQ EQUAL EQUIP EQUIPMENT ETR EXISTING TO REMAIN EXCAV EXCAVATE(TION) EXG EXISTING EXP EXPANDABLE EXPANSION EXT EXTERIOR EW EACH WAY EWC ELECTRIC WATER COOLER EWOC EACH WAY ON CENTER FA FIRE ALARM FACP FIRE ALARM CONTROL PANEL FAC FIN FACTORY FINISH FAS FASTEN(ER) FBO FURNISHED BY OTHERS FC FIRE CODE FD FLOOR DRAIN FE FIRE EXTINGUISHER FEB FIRE EXTING. BRACKET FEC FIRE EXTING. CABINET FF FINISH FLOOR FHS FIRE HOSE STATION FIN FINISH(ED) FIX FIXTURE FLASH FLASHING FLR FLOOR(ING) FOUND FOUNDATION FP FIREPROOF(ING FTG FOOTING FR FIRE RATED (RATING) FRM FRAME(D)(ING) FURR FURRING(ED) FV FIELD VERIFY FWC FABRIC WALL COVERING GA GAUGE GALV GALVANIZED GB GRAB BAR GC GENERAL CONTRACTOR GL GLASS OR GLAZING GYP BD GYPSUM BOARD HB HOSE BIB HC HOLLOW CORE HDBD HARDBOARD HDCP HANDICAP HDWD HARDWOOD HDWR HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HT HEIGHT HTG HEATING HVAC HEATING, VENTILATION & AIR CONDITIONING HW HOT WATER H/C HANDICAPPED ACCESSIBLE ID INSIDE DIAMETER INCL INCLUDE(D)(ING) INSUL INCLUDE(D)(TION) INT INTERIOR JAN JANITOR JST JOIST JT JOINT KO KNOCK OUT KD KNOCK DOWN LAM LAMINATE(D) LAV LAVATORY LB LAG BOLT LBL LABEL LH LEFT HAND LL LIVE LOAD LT LIGHT LT FIXT LIGHT FIXTURE LVR LOUVER LW LIGHT WEIGHT MAS MASONRY MATL MATERIAL(S) MAX MAXIMUM MB MACHINE BOLT MBR MEMBER MECH MECHANICAL MED MEDIUM MEM MEMBRANE MANF MANUFACTURER MH MANHOLE MIN MINIMUM MIR MIRROR MISC MISCELLANEOUS MO MASONRY OPENING MOD MODULAR MS MACHINE SCREW M SINK MOP SINK MTL METAL MULL MULLION NIC NOT IN CONTRACT NOM NOMINAL NR NOISE REDUCTION NRC NOISE REDUCTION COEFFICIENT NTS NOT TO SCALE OA OVERALL OC ON CENTER(S) OD OUTSIDE DIAMETER OF/CI OWNER-FURNISHED CONTRACTORINSTALLED OF/OI OWNER-FURNISHED OWNER INSTALLED OH OVERHEAD OPH OPPOSITE HAND OPNG OPENING OPP OPPOSITE PART PARTITION PEMB PRE-ENGINEERED METAL BUILDING PRKG PARKING PLAM PLASTIC LAMINATE PNT PAINT(ED) PREFIN PREFINISHED QT QUARRY TILE R RISER RA RETURN AIR RAD RADIUS RB RUBBER BASE RCP REINFORCED CONCRETE PIPE RD ROOF DRAIN REC RECOMMENDATION REF/RE: REFERENCE, REFER TO REINF REINFORCE(D)(ING) REQ'D REQUIRED REV REVISION(S), REVISED RH RIGHT HAND RM ROOM RO ROUGH OPENING ROW RIGHT OF WAY R/S ROD AND SHELF SCHED SCHEDULE SC SOLID CORE SD SOAP DISPENSER SF SQUARE FOOT(AGE) SQUARE FEET SH SINGLE HUNG SHT SHEET SHTG SHEATHING SM SIMILAR SJ SCORED JOINT SND SANITARY NAPKIN DISPENSER SPEC SPECIFICATION(S) SPKR SPEAKER SS SANITARY SEWER S SINK SERVICE SINK S STL STAINLESS STEEL STD STANDARD STL STEEL STD STANDARD STL STEEL STOR STORAGE STRUCT STRUCTURE(AL) SUSP SUSPENDED SY SQUARE YARD(S)(AGE) SYN SYNTHETIC T TREAD OR TOP TC TOP OF CURB TEMP TEMPERATURE T&G TONGUE & GROOVE THK THICK(NESS) TM TOP OF MASONRY TPH TOILET PAPER HOLDER TOM TOP OF MASONRY TOS TOP OF STEEL TOW TOP OF WALL TYP TYPICAL TV TELEVISION UNO UNLESS NOTED OTHERWISE UR URINAL VAR VARIATION, VARIABLE,VARIES VB VAPOR BARRIER VCT VINYL COMPOSITION TILE VERT VERTICAL VIF VERIFY IN FIELD VNR VENEER VWC VINYL WALL COVERING VWF VINYL WALL FABRIC W/ WITH WAINS WAINSCOT WC WATER CLOSET WD WOOD WH WATER HEATER WNDW WINDOW W/O WITHOUT WP WATERPROOF(ING) WS WOOD SCREW WWF WELDED WIRE FABRIC D22012 A000 10.21.22
MEDICAL
CITY ADOPTED BUILDING CODES City 2022 Administrative Codes The 2021 New Mexico Mechanical Code; including Appendixes A, B, C, and D The 2021 New Mexico Plumbing Code; including Appendixes A, B, C D, E, F, I, K, and L The 2012 New Mexico Solar Energy Code; • The 2018 International Energy Conservation Code; The 2015 New Mexico Commercial Building Code including Appendix Chapters E and I, but not including: Appendix Chapters A, B, C, D, F, G, H, J, and K; • The 2015 New Mexico Earthen Building Materials Code; The New Mexico Historic Earthen Building Code; The 2015 New Mexico Existing Building Code; • The 2015 International Code Council Performance Code for Building and Facilities, including all Appendix Chapters as published by the International Code Council; The 2017 New Mexico Electrical Code; • The 2012 New Mexico Electrical Safety Code; Errata sheets to the adopted portions of Codes promulgated by he International Code Council, International Association of Plumbing and Mechanical Officials and National Electrical Code SITE PROJECT LOCATION
SYCAMORE SQUARE
PROJECT NO. SHEET NO. PROJECT ISSUE DATE SHEET LIST SHEET LIST CURRENT ISSUE PREVIOUS ISSUE DELETED DRAWINGS NOTES: CURRENT ISSUE PREVIOUS ISSUE DELETED DRAWINGS NOTES: D22012 A001 10.21.22 SHEETTITLE GENERAL A000COVER  A001SHEET INDEX  A002CODE DATA / LIFE SAFETY EGRESS PLAN LEVEL 1 SITE PLAN  A003SECOND THIRD FLOOR LIFE SAFETY PLANS CODE DATA  ARCHITECTURAL A011CONSTRUCTION NOTES, KEY NOTES, AND PARTITION TYPES  A012TYP FULL PARTIAL HT NON-BEARING MTL STUD PART WALL  AD101DEMOLITION PLANGROUND LEVEL  AD102DEMOLITION PLANLEVEL 2  AD103DEMOLITION PLANLEVEL 3  A111FLOOR PLAN - LEVEL 1  A112FLOOR PLAN - LEVEL 2  A113FLOOR PLAN - LEVEL 3  A141REFLECTED CEILING PLAN LEVEL 1  A142REFLECTED CEILING PLAN LEVEL 2  A143REFLECTED CEILING PLAN LEVEL 3  A171REFLECTED CEILING PLAN DETAILS  A181ROOF PLAN  A201EXTERIOR BUILDING ELEVATIONS  A202EXTERIOR REFINISH BUILDING ELEVATIONS  A401STANDARD MOUNTING HEIGHTS AND RESTROOM CONFIGURATIONS  A501DOOR SCHEDULE  A502DOOR WINDOW STOREFRONT CURTAINWALL ELEVATIONS  A601COLOR SCHEDULES & DETAILS  A602ROOM FINISH FLOOR PLAN LEVEL 2  A603ROOM FINISH FLOOR PLAN LEVEL 3  A604INTERIOR ELEVATIONS  A605INTERIOR ELEVATIONS  A721CASEWORK SECTIONS (BASE, SINK AND UPPER CABINETS)  A722CASEWORK SECTIONS (TALL CABINETS & MISC DETAILS)  N O S S U E D F O R D A T E P E R M T S E T 1 0 2 1 2 2 S S U E D F O R D A T E P E R M T S E T 1 0 2 1 2 2
UP FAAP FEC =FIRE EXTINGUISHER AND CABINET FEB = FIRE EXTINGUISHER AND BRACKET = EXIT NAME AND CLEAR WIDTH = STAIRWAY AND WIDTH CAPACITY = LONGEST TRAVEL DISTANCE TO EXIT FACP = FIRE ALARM CONTROL PANEL FAAP = FIRE ALARM ANNUNCIATOR PANEL LIFE SAFETY PLAN LEGEND 36" 36" 1HR RATED WALL ACOUSTICAL (NON-RATED) PARTITION 1HR RATED WALL - ACOUSTICAL PARTITION TYPE LEGEND PARTITION TYPE TAG LEGEND A2r PARTITION TYPE CATEGORY VARIATION WITHIN CATEGORY MODIFIER MODIFIERS (all lower case): a = ACOUSTICAL (BATT INSULATION) = RATED = SMOKE ra = RATED ACOUSTICAL p = PARTIAL HEIGHT 36" "C2" "S-1" GARAGE - FIRST FLOOR 103 LOBBY 100 ELEVATOR EQUIPMENT ROOM 102 FIRE RISER 104 36" "B2" 32 EXISTING PARKING SPACES TO REMAIN PROPERTY LINE PROPERTY LINE EXISTING 1-HOUR SEPARATION TO REMAIN OUTSIDE FACE OF BUILDING ABOVE OUTSIDE FACE OF BUILDING ABOVE 1-HOUR FLOOR CEILING ASSEMBLY TO REMAIN CENTRAL AVENUE SE PROPERTY LINE PROPERTY LINE OPEN TO ABOVE VAN PARKING EXISTING SUIT TO REMAIN AS - IS EXISTING SUIT TO REMAIN AS - IS 36" "B1" 36" "C3" TYPE VB EXISTING BUILDING TYPE 1B EXISTING OPEN GARAGE EXISTING TO REMAIN SHOWN SHADED GROUND FLOOR 4,039 SF GARAGE 13,441 SF TOTAL 17,480 SF 36" "C1" 45 45 45 STAIR 101 45 36" "A" 45 FAAP BUILDING CODE DATA 2015 NEW MEXICO COMMERCIAL CODE AND 2015 NM EXISTING BUILDING CODE PROJECT: SYCAMORE SQUARE MEDICAL CENTER SINGLE TENANT (OWNER) WILL OCCUPY ENTIRE BUILDING FIRST FLOOR SPACES ARE EXISTING TO REMAIN. OCCUPANCY USE CLASSIFICATION, PER IBC SECTION 302: TYPE B BUSINESS W/ S-2 OPEN PARKING GARAGE CONSTRUCTION TYPE, PER IBC SECTION 602.2: TYPE V-B EXISTING BUILDING TYPE -B EXISTING OPEN PARKING GARAGE PER 2015 NM EXISTING BUILDING CODE, SECTION 505, THIS IS CONSIDERED ALTERATION LEVEL 3 BUILDING AREA: ALLOWABLE AREA PER IBC (TYPE V-B, SM, OCCUPANCY B)85,038 SF (SEE BUILDING AREA CALCS BELOW) ACTUAL BUILDING AREA 1ST FLOOR 17,480 SF 2ND FLOOR 10,084 SF 3RD FLOOR 10,084 SF (8,043 SF CONDITIONED SPACE + 2,041 SF BALCONY) TOTAL 37,648 SF BUILDING HEIGHT: ALLOWABLE HEIGHT IN FEET ABOVE GRADE PLANE 60 FEET (TABLE 504.3 ACTUAL HEIGHTIN FEET ABOVE GRADE PLANE 43 FEET (ROOF HT +AVG. GRADE HT) NO. OF STORIES ALLOWABLE NO. OF STORIES ABOVE GRADE PLANE 3 STORIES (TABLE 504.4) ACTUAL NO. OF STORIES ABOVE GRADE PLANE 3 STORIES FIRE PROTECTION SYSTEMS: AUTOMATIC FIRE SPRINKLER SYSTEM YES -AT BUILDING NO -AT OPEN PARKING GARAGE FIRE ALARM AND DETECTION SYSTEMS YES AT BOTH BUILDING AND OPEN PARKING GARAGE FIRE-RESISTANCE RATING REQ'MTS FOR BUILDING ELEMENTS:(TABLE 601) EXISTING BUILDING CONSTRUCTION -TYPE V-B STRUCTURAL ELEMENTMIN. REQ'D FIRE RESISTANCE RATING (TABLE 601) PRIMARY STRUCTURAL FRAME 0-HOUR BEARING WALLS EXT 0-HOUR BEARING WALLS INT 0-HOUR NON-BEARING EXT. WALLS (<30'-0") 0-HOUR NON-BEARING INT. PARTITIONS 0-HOUR FLOOR CONST AND SECONDARY MEMBERS 0-HOUR ROOF CONST AND SECONDARY MEMBERS 0-HOUR BUILDING AREA CALCULATIONS FRONTAGE INCREASE SINGLE-OCCUPANCY, MULTI-STORY BUILDING(TYPE V-B) If = [F/P -0.25] W/30 Aa = [At + (NS x If)] x Sa If = [215 533 -0.25] W/30 Aa = [27,000 + (9,000 x .1496)] x 3 If = [.1496] 30/30 Aa = [27,000 + (1,346)] x 3 If = .1496 Aa = [28,346] x3 Aa = 85,038 ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A002 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION CODE D ATA / LIFE SAF ETY EGRESS PLANLEVEL 1 / SITE PL AN SCALE: 1/8" = 1'-0" A002 1 LIFE SAFETY EGRESS PLAN -LEVEL 1 / SITE PLAN ZONING: IDO ZONE DISTRICT: MX-M IDO DISTRICT DEFINITION: MODERATE INTENSITY IDO ZONING DESCRIPTION: IDO CATEGORY: MIXED-USE OLD ZONING DESIGNATION: SU-2 OLD ZONING DESCRIPTION: CMU OLD ZONING CATEGORY: COMMERCIAL COMMERCIAL SERVICE LOCATED WITHIN PREMIUM TRANSIT STATION RADIUS PRESBYTERIAN STAT ON OCCUPANCY AND REQUIRED NUMBER OF PARKING SPACES DOES NOT CHANGE OR INCREASE THE REQUIRED NUMBER OF SPACES. 48 EXISTING PARKING SPACES PROVIDED NO.DESCRIPTIONDATE
DN UP FACP DN UP REF. 36" "E" 44" "S-2" 36" "D" 99' - 10" 2A 81' - 6" 2B ELEV EXISTING ELECTRICAL TRANSFORMER 16 EXISTING PARKING SPACES TO REMAIN 80' - 0" 2C FEB FEC FEB FEB FEB FEC FEC FEC 78' - 10" 2E 45 45 36" "G" 36" "F" BALCONY BALCONY BALCONY BALCONY ELEV 65' - 8" 3A 84' - 4" 3B 79' - 8" 3C 73' - 8" 3D 71' - 11" 3F 80' - 5" 3E FEC FEC FEC FEB FEC ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A003 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION O SECO ND THI RD FLOO R LIFE SAFETY PLANS / CODE DATA SCALE: 1/8" = 1'-0" A003 1 LIFE SAFETY PLAN -LEVEL 2 SITE PLAN SCALE: 1/8" 1'-0" A003 LIFE SAFETY EGRESS PLAN -LEVEL 3 45 45 NO.DESCRIPTIONDATE

EXISTING ROOF FLOOR

SIDE WALL FINISH SURFACES, UNLESS NOTED OTHERWISE.

13. INSTALL BLOCKING BEHIND, BUT NOT LIMITED TO, T.V. BRACKETS, TOILET ACCESSORIES, GRAB BARS, OVERHEAD CABINETRY, WRITING COUNTERS, MILLWORK KNEE BRACES, SHELVING, AND ALL MISC INTERIOR WALL-HUNG EQUIP. BLOCKING FOR HANDRAILS, GRAB BARS, AND VANITIES SHALL BE ADEQUATE

PARTITION TYPE GENERAL NOTES

1. ALL FIRE-RATED PARTITIONS SHALL BE NOTED ACCORDINGLY ABOVE CEILING WITH 2" HIGH BLOCK LETTERS IN RED PAINT ON BOTH SIDES OF WALL AT 10'-0" MIN. INTERVALS.

2. THERE SHALL BE NO CONTINUOUS HORIZONTAL GYPSUM BOARD JOINTS BELOW FINISH CEILING. 3. BLOCKING IN WALLS TO BE EITHER LIGHT GAGE (16GA METAL STUDS OR FIRE RETARDANT 2X WOOD BLOCKING AS INDICATED ON SHEET A012.

4. WHERE TOP SLIP TRACK IS SCHEDULED, DO NOT FASTEN GYPSUM BOARD THROUGH TOP SLIP TRACK, ONLY THROUGH VERTICAL STUD FRAMING BELOW SLIP TRACK.

5. WHERE STUDS, ARE FASTENED TO DECK, ONLY USE FASTENERS. THAT DO NOT PENETRATE THRU TOP OF DECKING. 6. ALL METAL STUD SPACING TO BE 16" O.C. (UNO) 7. ALL METAL STUDS TO BE 20 GAUGE (UNO)

GENERAL WALL TYPE NOTES

1. GYP BD TO BE 5/8" (UNO).

2. REF TO CODE REVIEW IN THE "GENERAL" SHEETS FOR LOCATIONS AND EXTENT OF RATED ASSEMBLIES.

3. PROVIDE CONT ACOUSTICAL SEALANT ON BOTH SIDES AT ADJACENT WALLS AND AT TOP AND BOTTOM OF GYPSUM BOARD ASSEMBLY WALLS TO FLOOR/ROOF DECK AND FLOOR.

4. PROVIDE ACOUSTICAL SEALANT AT BASE AND TOP OF WALLS CONTAINING ACOUSTICAL INSULATION.

5. AT TOILETS AND JANITOR CLOSETS USE MOISTURE - RESISTANT GYP BD INLINE OF STD EYP BD

DECKING ABOVE GYP BD EACH SIDE BRIDGING DEEP LEG SLOTTED SLIP TRACK FASTENED TO EACH STRAP WITH 2 FASTENERS OR TO BOTTOM OF DECK FASTEN GYP BD THRU STUDS MIN 3" BELOW TOP OF WALL FASTENERS SHALL NOT PENETRATE THROUGH TOP OF DECKING ACOUSTIC SEALANT TYP.(ON BOTH SIDES) 1" 1HR RATED WALL ACOUSTICAL (NON-RATED) PARTITION 1HR RATED WALL - ACOUSTICAL PARTITION TYPE LEGEND PARTITION TYPE TAG LEGEND A2r PARTITION TYPE CATEGORY VARIATION WITHIN CATEGORY MODIFIER MODIFIERS (all lower case): a = ACOUSTICAL (BATT INSULATION) = RATED s = SMOKE ra = RATED ACOUSTICAL p = PARTIAL HEIGHT 5/8" GYP BD (TYPE "X" AT RATED PARTITIONS) BOTH SIDES AS SCHEDULED 3 5/8" STUD @ A1, A7 6" STUD @ A2, A8 MTL TRACK BATT INSUL (WHERE SPECIFIED) FLOOR STRUCTURE SEALANT ENT PERIM (TYP BOTH SIDES) FIN BASE AS SCHEDULED ROOF FLOOR STRUCTURE ABOVE SEE BASE CONDITION FOR BALANCE OF INFORMATION REF SHEET A011 FOR DEFLECTION CONNECTION DETAILS CATEGORY A PARTITIONS TOP AT PARTITIONS A7 & A8 TOP AT PARTITIONS A1 & A2 8" MIN MTL TRACK FINISH CEILING REF SHEET A011 FOR DEFLECTION CONNECTION DETAILS SEE BASE CONDITION FOR BALANCE OF INFORMATION BASE CONDITION. ALL PARTITIONS MTL STUD M IN 3/8" 5/8" GYP BD ONE SIDE AS SCHEDULED 6" STUD @ B3, B6 MTL TRACK BATT INSUL (WHERE SPECIFIED) FLOOR STRUCTURE SEALANT ENT PERIM (TYP BOTH SIDES) FIN BASE AS SCHEDULED ROOF FLOOR STRUCTURE ABOVE SEE BASE CONDITION FOR BALANCE OF INFORMATION REF SHEET A011 FOR DEFLECTION CONNECTION DETAILS MTL TRACK FINISH CEILING TOP AT PARTITIONS B4 & B5 REF SHEET A011 FOR DEFLECTION CONNECTION DETAILS TOP AT PARTITIONS B1 & B2 SEE BASE CONDITION FOR BALANCE OF INFORMATION 2 1/2" STUD @ B1, B4 8" MIN 3 5/8" STUD @ B2, B5 "NO CLG" "NO CLG" CATEGORY B PARTITIONS BASE CONDITION. ALL PARTITIONS MTL STUD ACOUSTICALLY ENHANCED 5/8" GYP BD BOTH SIDES AS SCHEDULED 3 5/8" STUD @ F1 MTL TRACK 7/8" HAT CHANNEL at 24" OC ON SOUND ISOLATION CLIPS AT 48" OC FLOOR STRUCTURE ACOUSTIC SEALANT (TYP BOTH SIDES) FIN BASE AS SCHEDULED NOTE: SOUND ISOLATION CLIPS TO BE INSTALLED ON ROOM SIDE NOT CORRIDOR ROOF FLOOR STRUCTURE ABOVE SEE BASE CONDITION FOR BALANCE OF INFORMATION REF SHEET A011 FOR DEFLECTION CONNECTION DETAILS TOP AT ALL "F" PARTITIONS FINISH CEILING (REFER CEILING DETAILS) SOUND ATTENUATION BASE CONDITION. ALL PARTITIONS CATEGORY F PARTITIONS MTL STUD MIN 3/8" ESTIMATED STC - 59 ACOUSTIC SEALANT (TYP BOTH SIDES) NOTE: SOUND INSULATION MUST BE INSTALLED BETWEEN DOOR FRAME AND SOUND PARTITION WALL OPENINGS GENERAL NOTES - TYP ALL ARCH SHEETS 1. CONTRACTOR SHALL NOT SCALE THESE DRAWINGS FOR CONSTRUCTION PURPOSES. IN THE EVENT OF OMISSION OF NECESSARY DIMENSIONS, CONTRACTOR SHALL NOTIFY ARCHITECT. 2. VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE. 3. VERIFY SIZE, LOCATION, AND CHARACTERISTICS OF ALL WORK AND EQUIP TO BE FURNISHED BY OWNER OR OTHERS WITH MANUFACTURER OR SUPPLIER BEFORE ANY CONSTRUCTION PERTAINING TO SAME IS BEGUN. 4. VERIFY SIZE AND LOCATION OF ALL OPENINGS FOR MECH. EQUIP AND WORK WITH CONTRACTORS INVOLVED. 5. ERRORS AND/OR OMISSIONS IN ROOM FINISH SCHED AND DOOR SCHED DO NOT RELIEVE THE CONTRACTOR FROM WORK SHOWN ON DRAWINGS OR DESCRIBED IN THE SPECIFICATIONS. 6. CEILING HEIGHTS INDICATED ON THE REFLECTED CEILING PLANS ARE TAKEN FROM THE FINISH FLOOR ELEVATIONS. 7. ALL FRAMING DIMENSIONS ON PLAN, UNLESS NOTED OTHERWISE, ARE TO THE CENTERLINE OF STUD FRAMING, TO THE FACE OF CORRIDOR GYP BD, AND TO THE FACE OF THE EXT EDGE OF THE BUILDING SLAB. 8. IN LOCATING GLASS IN HM FRAMES, THE DIMENSIONS ARE TO THE FINISH HM FRAMES. 9. FURNISH AND INSTALL MTL CORNER BEADS AT ALL OUTSIDE CORNERS OF GYP BD PROVIDE MTL CASING BEADS WHERE GYP BD INTERSECTS OTHER MATERIALS. 10. FOR DUCT PENETRATIONS IN WALLS OTHER THAN ONE HOUR WALLS AROUND HAZARDOUS AREAS, SEAL GAPS WITH GYPSUM JOINT COMPOUND AND TAPE FOR GAPS LESS THAN 1/4". TIGHTLY PACK GAPS BETWEEN 1/4" AND 1/2" WITH FIRE SAFING INSULATION. GAPS LARGER THAN 1/2" ARE NOT ALLOWED. 11. SEAL ALL EDGES AND PENETRATIONS AROUND THE PERIMETER AND INTERIOR OF ALL CABINETS, EXPOSED PLUMBING AND DOOR FRAMES. 12. COORDINATE ROUGH-INS AND STUD WALL FRAMING LOCATIONS TO PROVIDE 18" OF CLEARANCE FROM THE CENTERLINE OF EACH WATER CLOSET BOWLS TO THE ADJACENT SIDE WALL FINISH SURFACE AND A MINIMUM OF 15" FROM THE CENTERLINE OF WALL- MOUNTED SINK TO THE ADJACENT
TO SUPPORT A MINIMUM OF 250 LBS OF BOTH VERTICAL AND OR HORIZONTAL LOADING FOR A MINIMUM OF 15 MINUTES. 14. PER IBC 1003.4, WALKING SURFACES OF THE MEANS OF EGRESS SHALL HAVE A SLIP-RESISTANT SURFACE AND BE SECURELY ATTACHED. LAYER 5/8" GYP BD 3 5/8" STUD @ E1 MTL TRACK BATT INSUL (WHERE SPECIFIED) FLOOR STRUCTURE SEALANT ENT PERIM (TYP BOTH SIDES) FIN BASE AS SCHEDULED ROOF FLOOR STRUCTURE ABOVE SEE BASE CONDITION FOR BALANCE OF INFORMATION REF SHEET A011 FOR DEFLECTION CONNECTION DETAILS TOP AT PARTITIONS E1 FINISH CEILING 8" MIN BASE CONDITION. ALL PARTITIONS CATEGORY E PARTITIONS MTL STUD M IN 3/8" BULLET-RESISTANT PANELI UP TO 8'0" GYP BD PANEL FROM 8'0" UP TO TOP OF PARTITIONTHICKNESS TO MATCH BULLET RESISTANT PANEL PARTITION CLOSURE EXISTING MULLION EXISTING GLAZING REFER WALL TYPE FOR EXACT PARTITION CONSTRUCTION CONT FOAM SEALANT TAPE MTL STUD AND TRACK. PONEY WALL INFILL BETWEEN EACH EXISTING BEAM/JOIST-SAME AS PARTITION BELOW GYP BD EACH SIDE BRIDGING DEEP LEG SLOTTED SLIP TRACK FASTENED TO EACH STRAP WITH FASTENERS OR TO BOTTOM OF DECK FASTEN GYP BD THRU STUDS MIN 3" BELOW TOP OF WALL ACOUSTIC SEALANT TYP.(ON BOTH SIDES) 1" RUNNER PERPENDICULAR TO EXISTING STRUCTURE EXISTING ROOF FLOOR DECKING ABOVE FASTNERS SHALL NOT PENETRATE THRU TOP OF DECKING ACOUSTIC SEALANT TYP (BOTH SIDES) NOTE: ACOUSTIC SEALANT TYP BOTH SIDES ALIGN BOT OF EXISTING BEAM/ JOIST ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A011 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION CONSTRUCTIO N NOTES, KEY NOTES, A ND PARTITIO N TYPES SCALE: 3" = 1'-0" A011 22 DEFLECTION CONNECTIONS AT TOP OF STUD WALL SCALE: 3" = 1'-0" A011 WALL PARTITION AT GLAZING AND MULLION SCALE: 3" = 1'-0" A011 TYP DETAIL AT FULL HT INT PARTITION DEMOLITION KEYNOTES BY SYMBOL D01EXISTING 1-HR RATED DRYWALL SOFFIT AT PARKING AREA SHOWN SHADED. NEATLY CUT AND REMOVE SOFFIT AS REQUIRED TO ACCOMMODATE NEW WORK. PROVIDE NEW ACCESS PANELS AS REQUIRED BY THE NEW WORK ABOVE. NEW ACCESS PANELS, IF REQUIRED, TO BE SIZED AND LOCATED TO ACCOMMODATE NEW WORK ABOVE PATCH AND REPAIR WITH LIKE MATERIALS AS REQUIRED TO MAINTAIN 1-HR FIRE RATING. PREP ALL SOFFIT SURFACES AS REQUIRED FOR NEW TEXTURE AND FINISH. D02EXISTING STUCCO SOFFIT TO REMAIN. PATCH AND REPAIR AS REQUIRED. PREP AS REQUIRED FOR NEW PAINT FINISH. D03REMOVE EXISTING STEEL FENCING AND GATE THIS AREA. D04NEATLY REMOVE EXISTING VINYL WALL BASE THROUGHOUT THIS ROOM AND PREP SURFACES AS REQUIRED FOR NEW WALL BASE. D05REMOVE ALL HARDWARE FROM THIS EXISTING DOOR AND FRAME AND REPLACE WITH NEW. REFER TO DOOR HARDWARE SCHEDULE. D06EXISTING DOOR ENTRY SYSTEM TO BE REMOVED AND REPLACED WITH NEW. TAKE CARE NOT TO DAMAGE ADJACENT SURFACES TO REMAIN. PREP EXISTING CONDITIONS AS REQUIRED TO ACCOMMODATE NEW ENTRY SYSTEM. D07EXISTING WINDOWS WITHIN BAY WINDOW SYSTEM TO BE REMOVED AND REPLACED WITH NEW. TAKE CARE NOT TO DAMAGE ADJACENT SURFACES TO REMAIN. PREP EXISTING CONDITIONS AS REQUIRED TO ACCOMMODATE NEW WINDOW SYSTEM. D08NEATLY REMOVE AND REINSTALL EXISTING LAY-IN CEILINGS THROUGHOUT THIS SUITE TO ACCOMMODATE NEW WORK ABOVE. D09REMOVE EXISTING PEDESTAL POST BOXES THIS AREA. D10REMOVE EXISTING ALARM ANNUNCIATOR PANEL THIS AREA. PATCH WALL SURFACES AS REQUIRED TO MATCH EXISTING. D11REMOVE EXISTING ILLUMINATED SIGNAGE BOX THIS AREA. PATCH WALL SURFACES AS REQUIRED TO MATCH EXISTING. D12REMOVE WALL PAINT FROM EXISTING COPPER HEADER TRIM ABOVE WINDOW. TAKE CARE NOT TO DAMAGE EXISTING METAL FINISH. D13REMOVE EXISTING SIGNAGE FROM WALL. D14REMOVE EXISTING DUCTWORK WEATHER HOOD THIS AREA. COORDINATE W/ MECHANICAL DRAWINGS. PATCH WALL OPENING AS REQUIRED TO MATCH EXISTING. D15REMOVE ALL PARTITIONS, DOORS, CEILINGS, FIXTURES, FINISHED FLOORING, ELECTRICAL, PLUMBING, MECHANICAL, ETC WITHIN THIS SUITE AND PREP FOR NEW CONSTRUCTION. DEMO SHALL INCLUDE REMOVAL OF ALL LAY-IN AND DRYWALL CEILINGS ATTACHED TO STRUCTURE ABOVE. REFER TO ALTERNATES FOR EXTERIOR PERIMETER WALL DEMO REQUIREMENTS. D16EXISTING CORE PARTITIONS AND ELEVATOR TO REMAIN. REMOVE OUTSIDE FACE OF GYP BOARD AND REPLACE WITH NEW. D18REMOVE GYP BD FROM ALL SURFACES OF EXISTING INTERIOR COLUMN WRAPS AND REPLACE WITH NEW 5/8" GYP BD. COORDINATE WITH NEW ADJACENT CONSTRUCTION. D19REMOVE EXISTING WOOD TRIM AROUND OVERFLOW SCUPPER AND REPLACE WITH NEW. USE HARDI-TRIM CEMENT BOARD IN LIEU OF WOOD. TRIM SIZE, CUT AND LAYOUT TO MATCH EXISTING. D20REMOVE EXISTING DAMAGED STUCCO WALL INSULATION THIS AREA AND PATCH IN NEW MATERIAL TO MATCH EXISTING. D21REMOVE EXISTING WINDOW SYSTEM AND PREP OPENING AS REQUIRED OR NEW INFILL WALL CONSTRUCTION. STUCCO WINDOW SILL AND COPPER HEAD TRIM ON OUTSIDE OF BUILDING THIS AREA TO REMAIN. TAKE CARE NOT TO DAMAGE. D22REMOVE EXISTING GYP BD ENTIRE LENGTH OF WALL THIS AREA AND REPLACE WITH NEW AS PART OF BASE BID. D23EXISTING MECH EQUIPMENT TO BE REMOVED (RE: MEP). D24EXISTING SATELLITE DISH SYSTEM TO BE REMOVED. D25AT FLOOR, INFILL NEW WOOD DECKING, UNDERLAYMENT AND 2X FRAMING. PLYWOOD DECKING AND UNDERLAYMENT THICKNESSES TO MATCH EXISTING AND TOP TO BE FLUSH WITH EXISTING ADJACENT FLOOR. CONSTRUCTION KEYNOTES BY SYMBOL 001NEW WALL INFILL INSIDE FORMER WINDOW OPENING EIFS ON INSUL BD ON 5/8" GYP SHEATHING ON METAL STUD FRAMING W/ BATT INSULATION INFILL. 002EXISTING METAL COPING FASCIA TRIM TO REMAIN AS-IS. DO NO PAINT OR DAMAGE. 003NEW SAFETY AND SECURITY FILM TO BE APPLIED TO ALL PANES OF EXISTING WINDOW THIS AREA (RE: SPEC). 004PROVIDE NEW FIRE ALARM ANNUNCIATOR PANEL THIS AREA (RE: ELEC). 005NEW WELDED WIRE SECURITY FENCE AND PRE-HUNG PEDESTRIAN EGRESS GATE SYSTEM (RE: SPEC + DOOR HARDWARE SCHEDULE). SYSTEM SHALL EXTEND FROM PAVING UP TO BOTTOM OF EXISTING SOFFIT ABOVE. NEATLY SAWCUT, REMOVE, AND REPLACE EXISTING PAVING AS REQUIRED TO ACCOMMODATE NEW FENCE POST ANCHORS. ANCHOR NEW FENCE POSTS IN CONCRETE PER MANUFACTURER'S WRITTEN REQUIREMENTS. 006USE 6" MTL STUD FRAMING FOR HEADER THIS AREA. NO.DESCRIPTIONDATE
FULL HT CABINETS 5' 0" DOUBLE STUDS DOOR OPENING DOUBLE DOOR OPENING DOUBLE STUDS 4' 6" MAX 8' - 6" MAX 4' 6" MAX 4' 6" MAX 8' 5" MAX DOUBLE STUDS DOUBLE STUDS 8' 6" MAX 8' 6" MAX 4' 6" MAX DOOR OPENING BELOW CEILING OPENING LARGE BELOW CEILING OPENING DOUBLE STUDS 20 GA BOTTOM TRACK (TYP) 1" X 20 GA MTL STRAP PLATES AT 3'-6" OC EA SIDE CRIPPLE STUD EA SIDE OF DOOR (1/2" MIN CLEARANCE) 2" WIDE X 20 GA MTL STRAP MTL TOP TRACK (TYP UNO) CRIPPLE STUD EA SIDE OF DOOR (1/2" MIN CLEARANCE) ABOVE CEILING OPENING OPENING ABOVE CEILING WHICH INTERRUPTS LOWER OPENING JAMB STUDS LARGE ABOVE CEILING OPENING 6/ A012 9/ A012 9/ A012 9/ A012 9/ A012 6/ A012 5/ A012 5/ A012 7/ A012 7/ A012 8/ A012 5/ A012 5/ A012 5/ A012 8/ A012 A012 4 A012 4 CEILING LINE FV FV FV FV A012 NOTE: REFER TO DETAIL 12/G201 FOR ADDITIONAL DOOR WINDOW FRAMING DETAILS AND NOTES. CRIPPLE STUD EA SIDE OF WINDOW (1/2" MIN CLEARANCE) DOOR OPENING DOUBLE DOOR OPENING BELOW CEILING OPENING LARGE BELOW CELING OPENING FULL HT CABINETS FULL HT WALL MTD WALL MTD CABINETS MILLWORK ATTACHED SHELVING 4' - 6" MAX DOUBLE STUDS (FULL HEIGHT) DOUBLE STUDS (FULL HEIGHT) 8' 6" MAX 4' 6" MAX DOUBLE STUDS (FULL HEIGHT) 8' - 6" MAX CRIPPLE STUD EA SIDE OF DOOR & WINDOW. TYP (1/2" MIN CLEARANCE) PROVIDE DIAGONAL BRACING OF TOP TRACK BETWEEN FULL HEIGHT STUDS (48" OC MAX) (TYP) MTL TOP TRACK (TYP UNO) 1" X 20 GA MTL STRAP PLATES AT 3'-6" OC EA SIDE 20 GA BOTTOM TRACK (TYP) 5' 0" 6/ A012 5/ A012 9/ A012 9/ A012 7/ A012 5/ A012 8/ A012 A012 A012 CEILING LINE NOTE: REFER TO DETAIL 12/G201 FOR ADDITIONAL DOOR WINDOW FRAMING DETAILS AND NOTES. FV FV FV FV A012 4 12" MIN 12" MIN 12" MIN 12" MIN FV MAX 3' 0" MAX 3' 0" (4) 1/2" DIA. ANCHOR BOLTS AS REQ'D (TYP) DOUBLE STUDS AT END (2)STUDS PER PONY WALL ANCHOR, (1) EA. SIDE - SCREWS AS REQ'D THRU WEB OF STUDS EA. SIDE (TYP) PREFAB PONY WALL ANCHOR SYSTEM (TYP) REFER TYPICAL MOUNTING HEIGHTS CONTINUOUS 20 GA 3" WIDE MTL BACK-UP PLATE 3-5/8" MIN DEEPER IF REQUIRED 20 GA MIN MTL RUNNER TRACK CLIP FLANGES TO FIT OVER STUDS MIN (3) #12 SCREWS EA STUD (TYP) MTL WALL STUDS REFER TYICAL MOUNTING HTS CLIP ANGLE -20 GAX 1-1/2" X 1-1/2" X 3" FOR 3-5/8" STUDS AND 5" FOR 6" STUDS EA SIDE 20 GA MTL TRACK DOUBLE 20 GA 3-5/8" OR 6" MTL STUDS 20 GA MTL TRACK CLIP ANGLE -20 GA X 1-1/2" X 1-1/2" X 3" FOR 3-5/8" STUDS AND 5" FOR 6" STUDS EA SIDE 20 GA MTL STUD 20 GA MTL TRACK CLIP ANGLE -20 GA X 1-1/2" X 1-1/2" X 3" FOR 3-5/8" STUDS AND 5" FOR 6" STUDS EA SIDE 20 GA MTL STUD 20 GA MTL TRACK CLIP ANGLE -20 GA X 1-1/2" X 1-1/2" X 3" FOR 3-5/8" STUDS AND 5" FOR 6" STUDS EA SIDE 20 GA MTL STUD 1" X 20 GA MTL STRAP PLATES AT 3'-6" O.C. EA SIDE 20 GA MTL FLOOR TRACK WHERE APPLIES DOUBLE 20 GA MTL STUDS 20 GA MTL FLOOR TRACK BELOW CLIP ANGLE-20 GA X 1-1/2" X 1-1/2" X 3" FOR 3-5/8" STUDS AND 5" FOR 6" STUDS EACH SIDE DOUBLE 20 GA MTL STUDS AT BOTH JAMBS 20 GA MTL FLOOR TRACK CLIP ANGLE-20 GA X 1-1/2" X 1-1/2" X 3" FOR 3-5/8" STUDS AND 5" FOR 6" STUDS EACH SIDE 1" X 20 GA MTL STRAP PLATES AT 3'-6" O.C. EA SIDE CONT 20 GA 1/2" DEEP LEG SLOTTED SLIP TRACK ATTACH TO MTL STUD LINE OF CEILING AS SCHEDULED PARTITION PARALLEL TO ROOF FRAM'G ABOVE (NON-RATED) DO NOT ATTACH GYP BD OR STUDS TO DEFLECTION TRACK IN THIS AREA CONT 2" WIDE X 20 GA MTL STRAP FOR TOP ATTACHMENT OF GYP BD 1" CRIPPLE STUD (TYP) 1/2" MIN CLEARANCE HM FRAME SHOWN DASHED LOCATE JAMB ANCHORS AS REQ'D - ANCHORS ON STRIKE SIDE OCCUR DIRECTLY OPPOSITE HINGE SIDE NOTE: PROVIDE 3 JAMB ANCHORS FOR DR HTS UP TO 7'-2" AND 4 ANCHORS FOR DR HTS 7'-3" UP TO 9'-0" FOR 3 - PIECE FRAMES PART RUNNER ANCHORED W/ TWO SUITABLE FASTENERS RUNNER SCREW ATTACHED TO STRUT STUD DBL MTL STUDS @ JAMB FULL HT OF WALL NOTE: TREAT WINDOW OPENINGS IN THE SAME MANNER AS DOORS FLR ANCHORS SECURED W/ NO LESS THAN TWO FASTENERS HM DR FRAME (HINGE SIDE) TEST REF WHI 651-0318-1 NOTE: 1. THIS D'TL ONLY APPLIES TO DOORS OF A CERTAIN WIDTH. REFER TO SPECS FOR FURTHER DIRECTION 2. WALL BD JTS ARE TO BE ON A SINGLE LAYER, OR FACE LAYER ON TWO FOR LAYER APPLICATIONS 3. NO DRYWALL JTS SHALL OCCUR WITHIN 12" OF THE CORNERS OF DOOR FRAMES UNLESS CONTROL JTS ARE INSTALLED AT THE CORNERS OF THE DOOR FRAME AS SHOWN. FIN CEILING (RE: SCHED) E-Z STRIP EJ TO DECK FIRE EXTINGUISHER AND CABINET (RE: SPEC) 4" MAX HANDLE 2'8" AFF MAX 4'-0" MAX 18" MAX. CHANNEL BRIDGING MAX. 18" FROM TOP OF STUDS CLIP ANGLE AND SCREWS AS REQUIRED STEEL STUDS -SIZE AND SPACING AS INDICATED DEFLECTION TRACK FASTENED TO STRUCTURE ABOVE 1" CLEARANCE BETWEEN TOP OF STUD AND DEFLECTION TRACK OPTIONAL MTL BACK-UP MOUNTING PLATE RE: G201 STEEL STUD DEFLECTION TRACK DETAILS SLOTTED STEEL STUD DEFLECTION TRACK GAP AS REQ'D SCREWS AS REQUIRED - ALLOW CLEARANCE BELOW SLIP TRACK EQUAL TO VOID ABOVE STUD DEEP LEG SLOTTED SLIP TRACK GAP AS REQUIRED MTL STUD SLIP TRACK AS REQ'D ON TOP OF STD DEEP LEG TRACK SCREWS AS REQ'D -ALLOW CLEARANCE BELOW SLIP TRACK EQ TO VOID ABOVE STUD NOTE: CONTRACTOR SHALL HAVE OPTION TO USE EITHER OF THESE DETAILS AT ALL AREAS WHERE MTL STUD FRAM'G ATTACHES TO DECK'G STRUCT ABOVE ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A012 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION TYP FU LL / PARTIAL HT NON-BEARIN G MT L ST UD PART WALL SCALE: 1/4" = 1'-0" A012 1 TYP FULL HEIGHT NON-BEARING METAL STUD INTERIOR PARTITION WALL SCALE: 1/4" = 1'-0" A012 2 TYP PARTIAL HEIGHT NON-BEARING METAL STUD INTERIOR PARTITION WALL SCALE: 3" = 1'-0" A012 TYP INT CONT. MTL, BACK-UP MOUNTING PLATE AT FRAM'G WALL DTL SCALE: 1 1/2" = 1'-0" A012 TYP LT GA MTL STUD MOUNTING D'TLS SCALE: 3" 1'-0" A012 5 TYP INT DBL DR/ LARGE HEAD DTL SCALE: 3" = 1'-0" A012 6 TYP INT SINGLE DR/ HEAD DTL SCALE: 3" = 1'-0" A012 7 TYP INT OPENING HEADER DTL SCALE: 3" = 1'-0" A012 8 TYP INT DBL DR/ LARGE JAMB DTL AT OPENING SCALE: 3" 1'-0" A012 9 TYP INT HM DR JAMB DTL SCALE: 3" = 1'-0" A012 10 TYP DTL AT TOP OF FULL HT INT PARTITION SCALE: 3" 1'-0" A012 11 TYP INT DOOR FRAM'G ELEV DTL (DRYWALL/NON-LOAD BEARING) SCALE: 3" = 1'-0" A012 12 TYP DRYWALL CONTROL JT @ DOOR DETAIL SCALE: 3/4" = 1'-0" A012 13 TYP FIRE EXTIN'G CAB ELEV DETAIL SCALE: 3/4" = 1'-0" A012 14 STEEL STUD DEFLECTION TRACK NO.DESCRIPTIONDATE
UP 1 5 2 3 4 A.1 C C A.5 A.5 B B D D 5.5 6 3.5 E 5.3 A PARKING PARKING ELEV EXISTING SUITE TO REMAIN AS-IS EXISTING SUITE TO REMAIN AS-IS D08 D07 D07 D12 D11 D06 D05 D05 D05 D09 D10 D05 D03 D02 D04 D05 D05 D13 D05 D04 D05 D03 D02 D05 D14 D14 D07 D07 D13 D08 D06 D01 SHADED SHADED D01 1. REFER TO SHEET A011 FOR ALL DEMO KEYNOTES. 2. THE TOTAL AMOUNT OF DEMOLITION REQUIRED FOR THE PROJECT IS NOT INDICATED ON THE PLANS. THEY ARE INCLUDED FOR THE CONVENIENCE OF THE CONTRACTOR. THEY INDICATE THE GENERAL EXTENT OF THE REMOVAL WORK REQUIRED. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FULLY INSPECT THE BUILDING AND VERIFY ALL CONDITIONS AND FULL EXTENT OF DEMOLITION PRIOR TO SUBMITTING BID. 3. THE SUBCONTRACTORS FOR PLUMBING, ELECTRICAL, AND HVAC ARE RESPONSIBLE FOR ESTABLISHING THE SCOPE OF DEMOLITION REQUIRED TO PERFORM THE WORK FOR THEIR RESPECTIVE TRADE. DEMOLITION DRAWINGS FOR THESE DISCIPLINES ARE INCLUDED FOR THE CONVENIENCE OF THE CONTRACTOR. 4. MAINTAIN BUILDING IN STRUCTURALLY SOUND CONDITION AT ALL TIMES. DO NOT REMOVE ANY PORTION OF THE BUILDING STRUCTURE INCLUDING COLUMNS, LOAD BEARING WALLS, BEAMS FLOOR CONSTRUCTION, PERIMETER WALLS OR FIREPROOFING OF STRUCTURAL ELEMENTS UNLESS SPECIFICALLY NOTED. 5. PROTECT ALL FINISHES AND COMPONENTS OF BUILDING WHICH ARE TO REMAIN. ANY DAMAGED MATERIAL, EQUIPMENT OR ITEMS TO REMAIN SHALL BE REPAIRED OR REPLACED TO MATCH EXISTING CONSTRUCTION, AND ARE THE RESPONSIBILITY OF THE G.C. 6. MAINTAIN CODE COMPLIANT AND UNOBSTRUCTED EXIT PATHS AT ALL TIMES. 7. VERIFY CONCEALED CONSTRUCTION CONDITIONS PRIOR TO REMOVAL OF ANY ITEMS. CAREFULLY ASSESS EACH ITEM TO BE REMOVED FOR DETRIMENTAL RESULTS IF REMOVED. PERFORM EXPLORATORY DEMOLITION TO DETERMINE METHODS OF ATTACHMENTS, UTILITY INTERFACES, INTERCONNECTIONS AND OTHER CONCEALED CONDITIONS PRIOR TO DEMOLITION. 8. PRIOR TO DEMOLITION WORK, THE CONTRACTOR SHALL ASSESS AND IDENTIFY UTILITIES WITHIN THE DEMOLITION AREA THAT SERVE OCCUPIED SPACES OUTSIDE OF THE AREA OF THAT PHASE OF WORK. THOSE UTILITIES SHALL BE PROTECTED AND RE-SUPPORTED WHERE NECESSARY TO MAINTAIN CONTINUITY OF SERVICE. 9. WHERE PARTIAL DEMOLITION IS NOT INDICATED BUT IS NECESSARY TO PERFORM NEW WORK, THAT AREA SHALL BE REMOVED AS NECESSARY AND REFINISHED/REPLACED TO MATCH THE EXISTING CONTIGUOUS CONSTRUCTION. 10. OWNER HAS FIRST RIGHT OF REFUSAL FOR ALL DEMO ITEMS. IF OWNER DOES NOT WISH TO RETAIN DEMO ITEMS, CONTRACTOR SHALL DISPOSE OF IN A PROPER MANNER. 11. CONTRACTOR SHALL RELOCATE ANY DEMO ITEMS THE OWNER WISHES TO RETAIN TO A LOCATION DESIGNATED BY THE OWNER. RELOCATION AREA TO BE WITHIN 10 MILE RADIUS OF THE CONSTRUCTION SITE. CONTRACTOR SHALL TAKE CARE TO NOT DAMAGE SUCH ITEMS DURING TRANSPORT. 12. ITEMS DESIGNATED TO BE REMOVED AND SALVAGED SHALL BE DELIVERED TO A SAFE REMOTE LOCATION FOR RETROFITTING OR A SAFE LOCATION ON SITE FOR CLEANING AND STORAGE BY THE CONTRACTOR. 13. THE CONTRACTOR SHALL ASSURE THE EXISTING BUILDING IS WEATHER TIGHT AT THE END OF EACH WORKDAY ANY DAMAGE TO THE EXISTING BUIDLING OR FURNISHING DUE TO CONTRACTOR NOT MAINTAINING THE BUILDING A WEATHER TIGHT CONDITION SHALL BE REPAIRED OR REPLACE TO ORIGINAL CONDITION BY THE CONTRACTOR AT CONTRACTOR'S EXPENSE. 14. PROTECTION IS TO BE PROVIDED AT ALL ROOF LEVELS OF EXISTING AND NEW DURING CONSTRUCTION AND ACCESS. GENERAL DEMOLITION NOTES ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 AD101 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION DEMOLITIO N PLA NG ROUND LEVEL SCALE: 1/8" 1'-0" AD101 DEMOLITION FLOOR PLAN -GROUND LEVEL NO.DESCRIPTIONDATE
DN UP UP 1 5 2 3 4 A.1 C C A.5 A.5 B B D D 5.5 6 3.5 E 5.3 A PARKING ELEV TELE ELEC SC D15 D04 D05 D16 D15 D05 D13 D14 D20 D14 D14 D21 D21 D21 D18 D15 TYP D22 D16 D05 D05 D25 D25 1. REFER TO SHEET A011 FOR ALL DEMO KEYNOTES. 2. THE TOTAL AMOUNT OF DEMOLITION REQUIRED FOR THE PROJECT IS NOT INDICATED ON THE PLANS. THEY ARE INCLUDED FOR THE CONVENIENCE OF THE CONTRACTOR. THEY INDICATE THE GENERAL EXTENT OF THE REMOVAL WORK REQUIRED. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FULLY INSPECT THE BUILDING AND VERIFY ALL CONDITIONS AND FULL EXTENT OF DEMOLITION PRIOR TO SUBMITTING BID. 3. THE SUBCONTRACTORS FOR PLUMBING, ELECTRICAL, AND HVAC ARE RESPONSIBLE FOR ESTABLISHING THE SCOPE OF DEMOLITION REQUIRED TO PERFORM THE WORK FOR THEIR RESPECTIVE TRADE. DEMOLITION DRAWINGS FOR THESE DISCIPLINES ARE INCLUDED FOR THE CONVENIENCE OF THE CONTRACTOR. 4. MAINTAIN BUILDING IN STRUCTURALLY SOUND CONDITION AT ALL TIMES. DO NOT REMOVE ANY PORTION OF THE BUILDING STRUCTURE INCLUDING COLUMNS, LOAD BEARING WALLS, BEAMS FLOOR CONSTRUCTION, PERIMETER WALLS OR FIREPROOFING OF STRUCTURAL ELEMENTS UNLESS SPECIFICALLY NOTED. 5. PROTECT ALL FINISHES AND COMPONENTS OF BUILDING WHICH ARE TO REMAIN. ANY DAMAGED MATERIAL, EQUIPMENT OR ITEMS TO REMAIN SHALL BE REPAIRED OR REPLACED TO MATCH EXISTING CONSTRUCTION, AND ARE THE RESPONSIBILITY OF THE G.C. 6. MAINTAIN CODE COMPLIANT AND UNOBSTRUCTED EXIT PATHS AT ALL TIMES. 7. VERIFY CONCEALED CONSTRUCTION CONDITIONS PRIOR TO REMOVAL OF ANY ITEMS. CAREFULLY ASSESS EACH ITEM TO BE REMOVED FOR DETRIMENTAL RESULTS IF REMOVED. PERFORM EXPLORATORY DEMOLITION TO DETERMINE METHODS OF ATTACHMENTS, UTILITY INTERFACES, INTERCONNECTIONS AND OTHER CONCEALED CONDITIONS PRIOR TO DEMOLITION. 8. PRIOR TO DEMOLITION WORK, THE CONTRACTOR SHALL ASSESS AND IDENTIFY UTILITIES WITHIN THE DEMOLITION AREA THAT SERVE OCCUPIED SPACES OUTSIDE OF THE AREA OF THAT PHASE OF WORK. THOSE UTILITIES SHALL BE PROTECTED AND RE-SUPPORTED WHERE NECESSARY TO MAINTAIN CONTINUITY OF SERVICE. 9. WHERE PARTIAL DEMOLITION IS NOT INDICATED BUT IS NECESSARY TO PERFORM NEW WORK, THAT AREA SHALL BE REMOVED AS NECESSARY AND REFINISHED/REPLACED TO MATCH THE EXISTING CONTIGUOUS CONSTRUCTION. 10. OWNER HAS FIRST RIGHT OF REFUSAL FOR ALL DEMO ITEMS. IF OWNER DOES NOT WISH TO RETAIN DEMO ITEMS, CONTRACTOR SHALL DISPOSE OF IN A PROPER MANNER. 11. CONTRACTOR SHALL RELOCATE ANY DEMO ITEMS THE OWNER WISHES TO RETAIN TO A LOCATION DESIGNATED BY THE OWNER. RELOCATION AREA TO BE WITHIN 10 MILE RADIUS OF THE CONSTRUCTION SITE. CONTRACTOR SHALL TAKE CARE TO NOT DAMAGE SUCH ITEMS DURING TRANSPORT. 12. ITEMS DESIGNATED TO BE REMOVED AND SALVAGED SHALL BE DELIVERED TO A SAFE REMOTE LOCATION FOR RETROFITTING OR A SAFE LOCATION ON SITE FOR CLEANING AND STORAGE BY THE CONTRACTOR. 13. THE CONTRACTOR SHALL ASSURE THE EXISTING BUILDING IS WEATHER TIGHT AT THE END OF EACH WORKDAY ANY DAMAGE TO THE EXISTING BUIDLING OR FURNISHING DUE TO CONTRACTOR NOT MAINTAINING THE BUILDING A WEATHER TIGHT CONDITION SHALL BE REPAIRED OR REPLACE TO ORIGINAL CONDITION BY THE CONTRACTOR AT CONTRACTOR'S EXPENSE. 14. PROTECTION IS TO BE PROVIDED AT ALL ROOF LEVELS OF EXISTING AND NEW DURING CONSTRUCTION AND ACCESS. GENERAL DEMOLITION NOTES ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 AD102 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION DEMOLITI ON P LANLEVE L 2 SCALE: 1/8" = 1'-0" AD102 1 DEMOLITION FLOOR PLAN -LEVEL 2 NO.DESCRIPTIONDATE
DN UP 1 1 5 5 2 2 3 3 4 4 A.1 C C A.5 A.5 B B D D 5.5 5.5 6 6 A PARKING BELOW ELEV SC D15 D15 D04 D05 D16 D14 D18 D19 D19 D05 TYP D14 D25 D25 1. REFER TO SHEET A011 FOR ALL DEMO KEYNOTES. 2. THE TOTAL AMOUNT OF DEMOLITION REQUIRED FOR THE PROJECT IS NOT INDICATED ON THE PLANS. THEY ARE INCLUDED FOR THE CONVENIENCE OF THE CONTRACTOR. THEY INDICATE THE GENERAL EXTENT OF THE REMOVAL WORK REQUIRED. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FULLY INSPECT THE BUILDING AND VERIFY ALL CONDITIONS AND FULL EXTENT OF DEMOLITION PRIOR TO SUBMITTING BID. 3. THE SUBCONTRACTORS FOR PLUMBING, ELECTRICAL, AND HVAC ARE RESPONSIBLE FOR ESTABLISHING THE SCOPE OF DEMOLITION REQUIRED TO PERFORM THE WORK FOR THEIR RESPECTIVE TRADE. DEMOLITION DRAWINGS FOR THESE DISCIPLINES ARE INCLUDED FOR THE CONVENIENCE OF THE CONTRACTOR. 4. MAINTAIN BUILDING IN STRUCTURALLY SOUND CONDITION AT ALL TIMES. DO NOT REMOVE ANY PORTION OF THE BUILDING STRUCTURE INCLUDING COLUMNS, LOAD BEARING WALLS, BEAMS FLOOR CONSTRUCTION, PERIMETER WALLS OR FIREPROOFING OF STRUCTURAL ELEMENTS UNLESS SPECIFICALLY NOTED. 5. PROTECT ALL FINISHES AND COMPONENTS OF BUILDING WHICH ARE TO REMAIN. ANY DAMAGED MATERIAL, EQUIPMENT OR ITEMS TO REMAIN SHALL BE REPAIRED OR REPLACED TO MATCH EXISTING CONSTRUCTION, AND ARE THE RESPONSIBILITY OF THE G.C. 6. MAINTAIN CODE COMPLIANT AND UNOBSTRUCTED EXIT PATHS AT ALL TIMES. 7. VERIFY CONCEALED CONSTRUCTION CONDITIONS PRIOR TO REMOVAL OF ANY ITEMS. CAREFULLY ASSESS EACH ITEM TO BE REMOVED FOR DETRIMENTAL RESULTS IF REMOVED. PERFORM EXPLORATORY DEMOLITION TO DETERMINE METHODS OF ATTACHMENTS, UTILITY INTERFACES, INTERCONNECTIONS AND OTHER CONCEALED CONDITIONS PRIOR TO DEMOLITION. 8. PRIOR TO DEMOLITION WORK, THE CONTRACTOR SHALL ASSESS AND IDENTIFY UTILITIES WITHIN THE DEMOLITION AREA THAT SERVE OCCUPIED SPACES OUTSIDE OF THE AREA OF THAT PHASE OF WORK. THOSE UTILITIES SHALL BE PROTECTED AND RE-SUPPORTED WHERE NECESSARY TO MAINTAIN CONTINUITY OF SERVICE. 9. WHERE PARTIAL DEMOLITION IS NOT INDICATED BUT IS NECESSARY TO PERFORM NEW WORK, THAT AREA SHALL BE REMOVED AS NECESSARY AND REFINISHED/REPLACED TO MATCH THE EXISTING CONTIGUOUS CONSTRUCTION. 10. OWNER HAS FIRST RIGHT OF REFUSAL FOR ALL DEMO ITEMS. IF OWNER DOES NOT WISH TO RETAIN DEMO ITEMS, CONTRACTOR SHALL DISPOSE OF IN A PROPER MANNER. 11. CONTRACTOR SHALL RELOCATE ANY DEMO ITEMS THE OWNER WISHES TO RETAIN TO A LOCATION DESIGNATED BY THE OWNER. RELOCATION AREA TO BE WITHIN 10 MILE RADIUS OF THE CONSTRUCTION SITE. CONTRACTOR SHALL TAKE CARE TO NOT DAMAGE SUCH ITEMS DURING TRANSPORT. 12. ITEMS DESIGNATED TO BE REMOVED AND SALVAGED SHALL BE DELIVERED TO A SAFE REMOTE LOCATION FOR RETROFITTING OR A SAFE LOCATION ON SITE FOR CLEANING AND STORAGE BY THE CONTRACTOR. 13. THE CONTRACTOR SHALL ASSURE THE EXISTING BUILDING IS WEATHER TIGHT AT THE END OF EACH WORKDAY ANY DAMAGE TO THE EXISTING BUIDLING OR FURNISHING DUE TO CONTRACTOR NOT MAINTAINING THE BUILDING A WEATHER TIGHT CONDITION SHALL BE REPAIRED OR REPLACE TO ORIGINAL CONDITION BY THE CONTRACTOR AT CONTRACTOR'S EXPENSE. 14. PROTECTION IS TO BE PROVIDED AT ALL ROOF LEVELS OF EXISTING AND NEW DURING CONSTRUCTION AND ACCESS. GENERAL DEMOLITION NOTES ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 AD103 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION DEMOLITI ON P LANLEVE L 3 SCALE: 1/8" = 1'-0" AD103 1 DEMOLITION FLOOR PLAN -LEVEL 3 NO.DESCRIPTIONDATE
UP FAAP 1 1 5 5 2 2 3 3 4 4 A.1 C A.5 A.5 B B D D 5.5 5.5 6 6 3.5 A EXISTING COVERED PARKING ELEV X101.0 X100.2 X100.0 X102.0 X104.0 X100.1 X105.2 LOBBY 100 ELEVATOR EQUIPMENT ROOM 102 LINE OF BUILDING ABOVE LINE OF BUILDING ABOVE LINE OF BUILDING ABOVE LINE OF BUILDING ABOVE LINE OF BUILDING ABOVE GARAGE - FIRST FLOOR 103 STAIR 101 NO WORK IN THIS SPACE (SHOWN HATCHED) FIRE RISER 104 GAS METER MECHANICAL MECHANICAL MAIL 1 A202 2 A202 3 A202 A202 5 A202 A202 8 A202 7 A202 A202 10 A202 11 A202 12 A202 NO WORK IN THIS SPACE (SHOWN HATCHED) OPEN TO SKY 001 003 002 004 005 006 106.0 105.0 X105.1 OFFICE OFFICE LOBBY OFFICE OFFICE OFFICE OFFICE I.T. CORRIDOR R.R. R.R. 2 3 2 2 2 X106.1 005 005 005 005 005 005 004 GENERAL NOTES 1. REFER TO SHEET A011FOR ALL CONST KEYNOTES (#) 2. REFER TO SHEET A011 FOR ALL PARTITION TYPES 3. REFER TO SHEET A501 FOR ALL DOOR WINDOW ELEVATIONS 4. REFER TO SHEET A601 FOR ROOM FINISH LEGEND 5. REFER TO SHEET A601 FOR MATERIAL FINISH LEGEND 6. REFER TO SHEET A601 FOR EQUIPMENT SCHEDULE (EQ-#) 7. REFER TO SHEET A702 FOR FIXTURE SCHEDULE (FX-##) 8. REFER TO PROJECT MANUAL FOR ALL TOILET ACCESSORIES (TA-##) AND GRAB BARS (GB-#). 9. COORDINATE EXACT PLACEMENT OF ALL CEILING DEVICES IN GYP BD CEILING EXPOSED STRUCTURE CEILING AREAS WITH ARCH PRIOR TO INSTALLATION. 10. WHERE WALL TYPE WITH GYP BD FINISH AND DIFFERENT THICKNESS JOIN IN SAME PLANE, ALIGN FACE OF GYP BD. 11. REFER TO SHEET A012 FOR TYPICAL NON-BEARING METAL STUD FRAMING DETAILS. 12. ALL DIMENSIONS ARE FROM COLUMN REFERENCE LINE TO CENTER OF STUD, UNLESS NOTED OTHERWISE. 13. PROVIDE FRT WOOD BLOCKING AT ALL TOILET PARTITIONS, GRAB BARS, AND HAND RAILS. 1HR RATED WALL ACOUSTICAL (NON-RATED) PARTITION 1HR RATED WALL - ACOUSTICAL PARTITION TYPE LEGEND PARTITION TYPE TAG LEGEND A2r PARTITION TYPE CATEGORY VARIATION WITHIN CATEGORY MODIFIER MODIFIERS (all lower case): a = ACOUSTICAL (BATT INSULATION) r = RATED s = SMOKE ra = RATED ACOUSTICAL p = PARTIAL HEIGHT DOOR MARK KEY A101A WALL/FIXTURE WHERE OCCURS MULTIPLE DOOR DESIGNATION AREA DESIGNATION SEE KEY PLAN DOOR/ROOM NO IN WALL (SEE PLAN) 4" TYP (UON) OR CENTER DOOR OF DOOR WITH CLOSER) 1'-0" CLR MIN (@ PUSH SIDE (AT LATCH SIDE) 1'-6" CLR MIN ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A111 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION FLOOR PLAN LEVEL 1 SCALE: 1/4" 1'-0" A111 PROPOSED FLOOR PLAN -FIRST STORY NO.DESCRIPTIONDATE
DN UP UP 1 1 5 5 2 2 3 3 4 4 A.1 C C A.5 A.5 B B D D 5.5 5.5 6 6 3.5 A EXISTING CORE 18' 0 1/8" 5' 3 1/2" ELEV 8' 0 1/4" E X IS T IN G C O R E 10'8 3/4" 6'8 1/4" JAN 238A IT 202A PATIENT TOILET 237C PATIENT TOILET 237D PUBLIC TOILET 202B SOIL UTILITY 237E PUBLIC TOIL 218B CLEAN SUPPLY 237B CONSULT #1 225 CONSULT #2 226 PROCEDURE #1 229 PROCEDURE #2 230 PROCEDURE #3 232 CONTROL STATION 233 PROCEDURE #4 234 PROCEDURE #5 235 EQUIP STORAGE 244 CLEAN SUPPLY 243 CLEAN WORK 242 SOILED WORK 241 UTILITY 240 JANITOR 236 SECURED LOBBY 200 PATIENT LOBBY 202 CONSULT 204 WORK RM 213 LOCKERS 219 WOMEN TOILET 220 STAFF TOILET 221 STAFF LOUNGE 223 JAN 222 DOCTOR OFFICE 216 RECOVERY 206 RECOVERY 237 ELEC 228 PROCEDURE #A 205 PROCEDURE #B 207 PROCEDURE #C 209 PROCEDURE #D 211 JAN 212 SOIL WORK 215 CLEAN WORK 217 PROCEDURE #E 208 CORRIDOR 203 CORRIDOR 214 CORRIDOR 218 CORRIDOR 227 CORRIDOR 239 CORRIDOR 227 CORRIDOR 239 CORRIDOR 218A CORRIDOR 231 10/ A604 33/ A604 19/ A604 21/ A604 32/ A604 20/ A604 31/ A604 24/ A604 36/ A604 35/ A604 23/ A604 27/ A604 13/ A604 9/ A604 12/ A604 22/ A604 2/ A604 3/ A604 8/ A604 7/ A604 6/ A604 PATIENT TOILET 210 34/ A604 211.0 39/ A604 37/ A604 X224.0 X201.0 216.0 217.0 206.0 204.0 212.0 219.0 223.0 230.0 237B.0 240.0 229.1 241.0 230.1 226.0 225.0 228.0 232.0 232.1 242.0 234.0 234.1 243.0 236.0 235.0 235.1 244.0 202.1 202B.0 237D.0 237C.0 218B.0 202.0 200.0 200.1 237.0 205.0 207.0 209.0 214.0 220.0 221.0 222.0 237E.0 206.1 229.0 210.0 215.0 208.0 213.0 227.0 RECOVERY 237A A1a A7 A7 A8 A2 A1a B2 A1a A1a A1 A1 A2a A1a A1a A1 A7 A7 A1 A1a A1a A1a A1a A1 A1a A1a A1a A8 A1a A1a A1a A1a A1a A1a A1a B2 A1a A1a A1a A1 A7 A1a A7 A7 A1 A1 A1a A1a A2a A1a A1a B2 B2 B2 A1 A8 A1a A7 A1a A1a A1a A1a A7 A1a A1a A2a A2a A1a A1a A1a A1a A1a B4 B4 A7 A7 A7 A7 F1a A2a A1a A1a A2a A1a B2a A1a A1a A7 A1a A7 A7 A1a A1a A7 A1a A2a A1a A2a A2a A2a B2 F1a F1a A1a A1a A1a A7 A7 A7 A7 A1a A1a A1a A1a STAIR 201 NURSE STATION 238 1 A202 A202 4 A202 A202 6 A202 8 A202 7 A202 A202 10 A202 11 A202 12 A202 EQ-07 EQ-07 EQ-08 EQ-09 EQ-06 EQ-05 EQ-05 EQ-05 EQ-05 EQ-05 EQ-11 EQ-11 EQ-04 EQ-04 EQ-04 EQ-04 EQ-04 EQ-03 EQ-03 EQ-03 EQ-03 EQ-03 EQ-02 EQ-02 EQ-02 EQ-02 EQ-02 EQ-02 EQ-02 EQ-02 EQ-01 EQ-01 EQ-01 EQ-01 EQ-01 EQ-02 EQ-02 EQ-02 EQ-02 EQ-02 EQ-02 EQ-02 EQ-02 EQ-02 28'0" 8'1" 4' 2" 3'8" 2'1" RO 3'4" 1'0 1/2" 4'0" 8' 11 3/4" +/- 5' 11" 2' 0 3/4" 12' 4 1/4" 6' 5" 1' 10" 8'3" 8'3 5/8" 3' 1" 3'4" 3'7" 13' 5 1/4" 1' 11" 6' 1" 5' 5" 13' 3" 6' 4 7/8" +/- 3' 1/8" 5' 3/4" 5' 5" 5' 2 1/8" +/8' - 4" 8' 1" 8' 6" 3' 4" 2' 1/2" 13' - 10 1/2" 28' 8 7/8" 5' 6" +/10' 7 5/16" 17'3 3/4" +/ALIGN 5'6" 4'7" 3' 4" 1'7" 4' -0" 1' 6" 12'0" 2' 7" 3'7" 4' 9 5/8" +/- 2' 6" 3' 4" RO 9' 2 3/16" 4 13/16" 3' 4" 2' 6" 5' 7" ALIGN ALIGN ALIGN ALIGN ALIGN ALIGN 10' -0" 6' 9 3/4" 2' 3" 6' 11" 10'8" 2'2" 5' 7" TYP TYP 4 6' 0" 3' 4" RO 4' 2" 9' - 8" 1' 6" 6' 7/16" +/- 9 3/16" 4' 2" HOLD 3' 0" 2' 3/16" 1'3" H O L D 3' 0" B4 28/ A604 3/ A604 3/ A604 OH A7 ALIGN ALIGN 5/ A604 EQ-09 CORRIDOR 224 4/ A604 20/ A604 29/ A604 30/ A604 17/ A604 15/ A604 25/ A604 11/ A604 30/ A604 OH ALIGN TO EDGE OF EXISTING JAMB 8' 10 1/8" +/STARTING POINT 3'-0" CLR 5' 1 9/16" CLEAR 11"5" 10' 11" 6' 7" ALIGN B2 A1a A7 6' 4 1/8" +/12" CLR 2' 2" ALIGN 13' 7 1/4" +/- 13' 3" 13' 5 1/4" +/- 13' - 6" ALIGN ALIGN B4 B4 A2a EQ EQ 13' 9 1/8" CENTER WALL ON MULLION 13' 3 3/8" +/13'5" 5'5" 13' 11" 8' 2" 4' 6" 6'5" 3' 0 1/2" 5' 11" 5' 9" 1' 10" OPENING 5'6" 8' 2" 13'11 1/2" 3'2" 2'3" 5'8" 2' 5" 1' 10 1/2" RO 3' 4" 2' 0" A1a A8 3' 2" 5' 11" CENTER WALL ON MULLION 5' 11" CENTER WALL ON MULLION ALIGN RO 3' 4" 7'1" B2 B5 B5 ALIGN TO EDGE OF EXISTING JAMB ALIGN ALIGN TO EDGE OF EXISTING JAMB C L E A R 11' 4 9/16" 18/ A604 14' 2 5/16" CLEAR ALIGN TO EDGE OF EXISTING JAMB ALIGN OF FIN 2'1" FACE 238A.0 OF FIN 1' 8" FACE 26/ A604 TA2 TA2 TA14 TA14 Room Room ? ? SC ALIGN A8 F1a 1/ A604 1/ A604 OH FEB FEC FEB FEC FEC FEB FEB CENTER WALL ON MULLION A7 CENTER WALL ON MULLION FEC FEC FEC A1 A7 A1a A1a A1a A1a A7 B2 EQ-10 B5 A7 A7 A7 B2a A1 B4 B4 A1 A7 A1a A1a FEB A1 A1a 16/ A604 6' 0 1/8" 25/ A604 1' 3" EQ-07 EQ-07 EQ-07 EQ-16 EQ-20 EQ-16 EQ-18 EQ-07 2' 0" 37/ A604 2' 5" A2 14/ A604 7 003 003 003 003 003 003 003 003 003 003 003 003 003 003 003 003 003 003 003 003 003 003 003 003 202A.0 001 001 001 5' 11" 003 003 003 003 003 A8 1'9 5/8" 4' 6" GENERAL NOTES 1. REFER TO SHEET A011FOR ALL CONST KEYNOTES (#) 2. REFER TO SHEET A011 FOR ALL PARTITION TYPES 3. REFER TO SHEET A501 FOR ALL DOOR WINDOW ELEVATIONS 4. REFER TO SHEET A601 FOR ROOM FINISH LEGEND 5. REFER TO SHEET A601 FOR MATERIAL FINISH LEGEND 6. REFER TO SHEET A601 FOR EQUIPMENT SCHEDULE (EQ-#) 7. REFER TO SHEET A702 FOR FIXTURE SCHEDULE (FX-##) 8. REFER TO PROJECT MANUAL FOR ALL TOILET ACCESSORIES (TA-##) AND GRAB BARS (GB-#). 9. COORDINATE EXACT PLACEMENT OF ALL CEILING DEVICES IN GYP BD CEILING EXPOSED STRUCTURE CEILING AREAS WITH ARCH PRIOR TO INSTALLATION. 10. WHERE WALL TYPE WITH GYP BD FINISH AND DIFFERENT THICKNESS JOIN IN SAME PLANE, ALIGN FACE OF GYP BD. 11. REFER TO SHEET A012 FOR TYPICAL NON-BEARING METAL STUD FRAMING DETAILS. 12. ALL DIMENSIONS ARE FROM COLUMN REFERENCE LINE TO CENTER OF STUD, UNLESS NOTED OTHERWISE. 13. PROVIDE FRT WOOD BLOCKING AT ALL TOILET PARTITIONS, GRAB BARS, AND HAND RAILS. 1HR RATED WALL ACOUSTICAL (NON-RATED) PARTITION 1HR RATED WALL - ACOUSTICAL PARTITION TYPE LEGEND PARTITION TYPE TAG LEGEND A2r PARTITION TYPE CATEGORY VARIATION WITHIN CATEGORY MODIFIER MODIFIERS (all lower case): a = ACOUSTICAL (BATT INSULATION) = RATED s = SMOKE ra = RATED ACOUSTICAL p = PARTIAL HEIGHT DOOR MARK KEY A101A WALL/FIXTURE WHERE OCCURS MULTIPLE DOOR DESIGNATION AREA DESIGNATION SEE KEY PLAN DOOR/ROOM NO IN WALL (SEE PLAN) 4" TYP (UON) OR CENTER DOOR OF DOOR WITH CLOSER) 1'-0" CLR MIN (@ PUSH SIDE (AT LATCH SIDE) 1'-6" CLR MIN ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A112 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION FLOOR PLAN LEVEL 2 SCALE: 1/4" = 1'-0" A112 1 PROPOSED FLOOR PLAN -SECOND STORY NO.DESCRIPTIONDATE
DN UP REF. 1 1 5 5 2 2 3 3 4 4 A.1 C C A.5 A.5 B B D D 5.5 5.5 6 6 A 20/ A605 17/ A605 16/ A605 14/ A605 13/ A605 31/ A605 32/ A605 11/ A605 4/ A605 5/ A605 8/ A605 1' 9 1/4" +/4' 2 1/2" 6' 5" 12' 2" 9' 3" 4' 7 1/4" +/- 1' 6" 19' 5" 5' 1" 7' 8" 5' 5" 1' 8" 11' 0 7/16" 4' 10" 1/ A605 CORRIDOR 319 CORRIDOR 329 CORRIDOR 334 STAFF LOCKERS 331A 18/ A605 15/ A605 CORRIDOR 331B BUSINESS OFFICE 332 2/ A605 13' 10" MED RECORDS 332A SCHEDULERS 332C MENS RESTROOM 336 ELEC 330 WOMEN'S RESTROOM 338 CONSULT #1 326 STAFF TOILET 324 STAFF TOILET 322 CONSULT #2 327 CONSULT #7 317 CONSULT #6 315 CONSULT #5 309 CONSULT #4 307 CONSULT #3 305 DIRECTOR 323 ADMIN ASSIST 321 EXEC ADMIN 320 ADMIN 318 WORK RM 316 LAB 314 PATIENT TOILET 311 EXAM #2 312 EXAM #1 310 SONO EXAM #3 308 SONO EXAM #2 306 SONO EXAM #1 304 WORK RM 328 CHECK-IN 335 OFFICE DIRECTOR 332D STAFF LOUNGE 331 RECEPTION 332E SECURED LOBBY 300 LOBBY 333 JAN 337 NURSE PRACTITIONER 303A ELEV LOBBY 302 CORRIDOR 303 CORRIDOR 313 LOBBY 325 7/ A605 6/ A605 10/ A605 2' 8" 6' 11" 3' 4" 6'10 1/2" 4'0 1/2" 5' 7" 19' - 11" 12/ A605 29/ A605 19/ A605 6'5" 2' 6" 3'2" 2' 9 1/2" 4'0 1/2" 2'4" 2' 8" 5'11" +/ALIGN ALIGN ALIGN ALIGN ALIGN ALIGN ALIGN 3/ A605 X304.1 X321.3 X332A.1 X331.1 X329.1 X301.0 337.0 336.0 338.0 331B.0 332D.0 332C.0 332.0 332A.0 331.0 330.0 331A.0 335.0 300.0 300.1 304.0 306.0 308.0 310.0 312.0 309.0 307.0 305.0 314.0 315.0 327.0 326.0 316.0 317.0 319.0 318.0 320.0 321.0 329.0 325.0 311.0 321.2 323.0 324.0 322.0 320.1 328.0 X333.0 X332.1 STAIRS 301 ALIGN BALCONY 340 BALCONY 341 BALCONY 342 BALCONY 343 A8 B4 B4 B4 A7 A1a A1a A8 A1a A8 A1a A1a A7 A7 A7 A8 A1a A7 A2a A1a A1a A1a A1 A1 A1a A7 A1a A1 A1a A7 A7 A7 E1 E1 E1 A1a B4 A7 A7 A7 A1a A1a B4 B4 B4 F1a A1a F1a F1a A1a A1a A1a A2a A1a A7 A7 A7 A1a A1a A1a A1a A1a A1a A1a F1a F1a F1a F1a F1a A1a F1a F1a F1a A1a A1a A1a F1a F1a A1a B2 A1a F1a A1a F1a A1a F1a A1a F1a A1a F1a A1a A1a A1 A7 ALIGN ALIGN ALIGN ALIGN 1 A202 2 A202 3 A202 A202 5 A202 A202 8 A202 7 A202 A202 10 A202 11 A202 12 A202 EQ-04 EQ-04 EQ-04 EQ-04 EQ-12 EQ-13 EQ-14 EQ-15 EQ-15 EQ-11 EQ-04 43' - 1 3/8" 22' 8 1/2" 8' 6 3/8" 9' - 7 5/8" 12' 5" +/ALIGN TO EDGE OF WINDOW JAMB 12' - 8 7/16" 5'-1/2" RO 3' 4" 6" 7'-7 1/2" 2' 4 1/2" 11' 2" 1' 10" 3' 4" 4'8" 11' 1/4" 10' 8" 10' 8" 10' 8" 10' 7" EQ-04 2'9" 3' 4" 3'9" 9' 10" 10" 4'10" 6'10" 5'-0" 9'7 1/2" 5'8" 4'6 1/2" 4'0" 5'7" 5'5 1/8" +/28'5 15/16" 14' - 7 5/8" +/EXISTING CORE 8' 8" 9" 5' 5" 9'6" ALIGN 10' 1" 9' 1/2" 9' 7" 10' 5" 6' 5" 11' 3/4" +/- 10' 5" 2' 11" 8' 5" 2' 4" 8' 11" 8' 3 1/2" +/ALIGN 7' 0" 23'9 3/4" 11' 7 5/8" 1'6" 1' 6" 9' 11" 3'8" 5' 1/8" 10' 1" 8' 11 1/2" TYP 6' 5 1/8" ALIGN ALIGN ALIGN 10 11 2' 11" 8 9/ A605 30/ A605 3/ A605 3/ A605 3/ A605 3/ A605 ALIGN ALIGN 2' - 10" 3' 4" RO 4' 3" 8' 11" E X IS T IN G C O R E 10'8 3/4" 4'5" 7 7/16" 2'2 1/2" CENTER WALL ON MULLION OPENING 3' 0" 7' 6" ALIGN 12" CLR B2 10' - 3" A2a 3' - 11" 3' 4" RO 2' - 10" 2' 10" 3' 4" RO 2' 9 1/2" 11 4' 6 1/2" CLR 1' 7 1/4" 3' 3" 2' 6" 2' 10" 2' -6" 3' - 6" 2' 6" 2' - 6" 10 1' 6" ALIGN 2' 8" 2' 8" CENTER WALL ON MULLION A011 TYP A011 TYP 2'6" 3' 4" 4'5" A011 TYP A1a TA14 TA14 9 9 SC FEC FEC FEC FEC FEB FEC A7 A7 A1a 28/ A605 A1a A1 A1 A1a B4 A2a A1a B4 EQ-03 EQ-03 EQ-03 EQ-03 EQ-03 EQ-17 EQ-18 SEATING (OF/OI) 2' 6" 2' 1" 2' 0" 1' 6" 21/ A605 21/ A605 5' 0" 2'0" 3' 1" 3' 1" 3'1 1/4" 3' 8 1/2" 3'8 1/2" 3' 1" 3'1" ALIGN 6' 3" 6' 7" 6' 7" 7 1/4" 1/4" A8 A8 7' 3 1/2" 7 1/4" GENERAL NOTES 1. REFER TO SHEET A011FOR ALL CONST KEYNOTES (#) 2. REFER TO SHEET A011 FOR ALL PARTITION TYPES 3. REFER TO SHEET A501 FOR ALL DOOR WINDOW ELEVATIONS 4. REFER TO SHEET A601 FOR ROOM FINISH LEGEND 5. REFER TO SHEET A601 FOR MATERIAL FINISH LEGEND 6. REFER TO SHEET A601 FOR EQUIPMENT SCHEDULE (EQ-#) 7. REFER TO SHEET A702 FOR FIXTURE SCHEDULE (FX-##) 8. REFER TO PROJECT MANUAL FOR ALL TOILET ACCESSORIES (TA-##) AND GRAB BARS (GB-#). 9. COORDINATE EXACT PLACEMENT OF ALL CEILING DEVICES IN GYP BD CEILING EXPOSED STRUCTURE CEILING AREAS WITH ARCH PRIOR TO INSTALLATION. 10. WHERE WALL TYPE WITH GYP BD FINISH AND DIFFERENT THICKNESS JOIN IN SAME PLANE, ALIGN FACE OF GYP BD. 11. REFER TO SHEET A012 FOR TYPICAL NON-BEARING METAL STUD FRAMING DETAILS. 12. ALL DIMENSIONS ARE FROM COLUMN REFERENCE LINE TO CENTER OF STUD, UNLESS NOTED OTHERWISE. 13. PROVIDE FRT WOOD BLOCKING AT ALL TOILET PARTITIONS, GRAB BARS, AND HAND RAILS. 1HR RATED WALL ACOUSTICAL (NON-RATED) PARTITION 1HR RATED WALL - ACOUSTICAL PARTITION TYPE LEGEND PARTITION TYPE TAG LEGEND A2r PARTITION TYPE CATEGORY VARIATION WITHIN CATEGORY MODIFIER MODIFIERS (all lower case): a = ACOUSTICAL (BATT INSULATION) r = RATED s = SMOKE ra = RATED ACOUSTICAL p = PARTIAL HEIGHT DOOR MARK KEY A101A WALL/FIXTURE WHERE OCCURS MULTIPLE DOOR DESIGNATION AREA DESIGNATION SEE KEY PLAN DOOR/ROOM NO IN WALL (SEE PLAN) 4" TYP (UON) OR CENTER DOOR OF DOOR WITH CLOSER) 1'-0" CLR MIN (@ PUSH SIDE (AT LATCH SIDE) 1'-6" CLR MIN ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A113 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTER FLOOR PLAN LEVEL 3 SCALE: 1/4" = 1'-0" A113 1 A113 -LEVEL 3 -FLOOR PLAN NO.DESCRIPTIONDATE
EXISTING TO REMAIN (SHOWN HATCHED) EXISTING TO REMAIN (SHOWN HATCHED) 10' - 5 7/8" 10' - 5 7/8" 24" X 24" SUSPENDED ACCOUSTIC LAY-IN CLG GYP BD CLG FURRDOWN ABOVE MILLWORK AIR DEVICES (RE: MECH) REFLECTED CEILING PLAN LEGEND FLOOR LIGHT FIXTURE (RE: ELEC) FLOOR LIGHT FIXTURE (RE: ELEC) RECESSED LIGHT FIXTURE (RE: ELEC PENDANT LIGHT FIXTURE (RE: ELEC SURFACE MTD OR SUSP LIGHT FIXTURE (RE: ELEC) FLOOR LIGHT FIXTURE (RE: ELEC) GENERAL RCP NOTES 1.FIELD VERIFY ALL BULKHEAD DIMENSIONS PRIOR TO CONSTRUCTION. 2.PROVIDE CJ'S AT 30'-0" O.C. MAX AT ALL GYP BD BULKHEADS. 3.ALIGN CONTROL JOINTS (CJ'S) WITH WALLS & EDGES OF COLUMN WRAPS @ EXTERIOR PCP SOFFITS, TYP. U.O.N. 4.REFER TO MEP DOCUMENTS & COORDINATE THE LOCATIONS OF LIGHTS, DIFFUSERS, ETC., BRING ANY CONFLICTS TO THE ATTENTION OF THE ARCHITECT. GENERAL NOTES 1. REFER TO SHEET A011FOR ALL CONST KEYNOTES (#) 2. REFER TO SHEET A011 FOR ALL PARTITION TYPES 3. REFER TO SHEET A501 FOR ALL DOOR WINDOW ELEVATIONS 4. REFER TO SHEET A601 FOR ROOM FINISH LEGEND 5. REFER TO SHEET A601 FOR MATERIAL FINISH LEGEND 6. REFER TO SHEET A601 FOR EQUIPMENT SCHEDULE (EQ-#) 7. REFER TO SHEET A702 FOR FIXTURE SCHEDULE (FX-##) 8. REFER TO PROJECT MANUAL FOR ALL TOILET ACCESSORIES (TA-##) AND GRAB BARS (GB-#). 9. COORDINATE EXACT PLACEMENT OF ALL CEILING DEVICES IN GYP BD CEILING EXPOSED STRUCTURE CEILING AREAS WITH ARCH PRIOR TO INSTALLATION. 10. WHERE WALL TYPE WITH GYP BD FINISH AND DIFFERENT THICKNESS JOIN IN SAME PLANE, ALIGN FACE OF GYP BD. 11. REFER TO SHEET A012 FOR TYPICAL NON-BEARING METAL STUD FRAMING DETAILS. 12. ALL DIMENSIONS ARE FROM COLUMN REFERENCE LINE TO CENTER OF STUD, UNLESS NOTED OTHERWISE. 13. PROVIDE FRT WOOD BLOCKING AT ALL TOILET PARTITIONS, GRAB BARS, AND HAND RAILS. ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A141 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTER REFLECTED CEILING PLAN LEVEL 1 SCALE: 1/8" = 1'-0" A141 1 REFLECTED CEILING PLAN -FIRST STORY NO.DESCRIPTIONDATE
REF. JAN 238A IT 202A PATIENT TOILET 237C PATIENT TOILET 237D PUBLIC TOILET 202B SOIL UTILITY 237E PUBLIC TOIL 218B CLEAN SUPPLY 237B CONSULT #1 225 CONSULT #2 226 PROCEDURE #1 229 PROCEDURE #2 230 PROCEDURE #3 232 CONTROL STATION 233 PROCEDURE #4 234 PROCEDURE #5 235 EQUIP STORAGE 244 CLEAN SUPPLY 243 CLEAN WORK 242 SOILED WORK 241 UTILITY 240 ELEC 228 JANITOR 236 LOBBY 200 PATIENT LOBBY 202 CONSULT 204 PROCEDURE #A 205 PROCEDURE #B 207 PROCEDURE #C 209 PROCEDURE #D 211 JAN 212 WORK RM 213 SOIL WORK 215 CLEAN WORK 217 LOCKERS 219 WOMEN TOILET 220 STAFF TOILET 221 STAFF LOUNGE 223 JAN 222 DOCTOR OFFICE 216 PROCEDURE #E 208 RECOVERY 206 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 7' - 6" 8' - 0" 8' - 0" NURSE STATION 238 RECOVERY 237 CORRIDOR 203 CORRIDOR 214 CORRIDOR 218 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 7' - 6" 7' - 6" 7' - 6" 7' - 6" CORRIDOR 227 CORRIDOR 239 RECOVERY 237 7' - 6" PATIENT TOILET 210 8' - 0" 8' - 0" 8' - 0" CORRIDOR 224 7' - 6" 7' - 6" 7' - 6" RECOVERY 237A CORRIDOR 218A 8' - 0" 8' - 0" 2'1" 2'1" 7' - 6" 8' - 0" 8' - 0" 7' - 6" 7' - 6" 7' - 6" 1 A171 A171 2 A171 2 A171 1 A171 1 A171 1 A171 1 A171 1 A171 1 A171 1 A171 A171 2 A171 2 A171 2 A171 A171 A171 2 A171 2 A171 2 A171 2 A171 2 A171 2 A171 2 A171 2 A171 2 A171 3 A171 2 A171 2 A171 2 A171 2 A171 2 A171 A171 1' 6" 3'0" 7 1/4" 1/4" 7 1/4" 1' 1/4" 8' - 0" 8' - 0" 7' - 6" 8' - 0" CORRIDOR 231 EQ EQ 6' 0" EQ EQ EQ EQ EQ EQ EQ EQ 8' - 0" 7' - 6" ALIGN 4" EQ EQ EQ EQ ALIGN ALIGN EQ EQ 8' - 0" 7' - 6" 7' - 0" 8' - 0" 006 006 006 006 006 006 24" X 24" SUSPENDED ACCOUSTIC LAY-IN CLG GYP BD CLG FURRDOWN ABOVE MILLWORK AIR DEVICES (RE: MECH) REFLECTED CEILING PLAN LEGEND FLOOR LIGHT FIXTURE (RE: ELEC) FLOOR LIGHT FIXTURE (RE: ELEC) RECESSED LIGHT FIXTURE (RE: ELEC PENDANT LIGHT FIXTURE (RE: ELEC SURFACE MTD OR SUSP LIGHT FIXTURE (RE: ELEC) FLOOR LIGHT FIXTURE (RE: ELEC) GENERAL RCP NOTES 1.FIELD VERIFY ALL BULKHEAD DIMENSIONS PRIOR TO CONSTRUCTION. 2.PROVIDE CJ'S AT 30'-0" O.C. MAX AT ALL GYP BD BULKHEADS. 3.ALIGN CONTROL JOINTS (CJ'S) WITH WALLS & EDGES OF COLUMN WRAPS @ EXTERIOR PCP SOFFITS, TYP. U.O.N. 4.REFER TO MEP DOCUMENTS & COORDINATE THE LOCATIONS OF LIGHTS, DIFFUSERS, ETC., BRING ANY CONFLICTS TO THE ATTENTION OF THE ARCHITECT. GENERAL NOTES 1. REFER TO SHEET A011FOR ALL CONST KEYNOTES (#) 2. REFER TO SHEET A011 FOR ALL PARTITION TYPES 3. REFER TO SHEET A501 FOR ALL DOOR WINDOW ELEVATIONS 4. REFER TO SHEET A601 FOR ROOM FINISH LEGEND 5. REFER TO SHEET A601 FOR MATERIAL FINISH LEGEND 6. REFER TO SHEET A601 FOR EQUIPMENT SCHEDULE (EQ-#) 7. REFER TO SHEET A702 FOR FIXTURE SCHEDULE (FX-##) 8. REFER TO PROJECT MANUAL FOR ALL TOILET ACCESSORIES (TA-##) AND GRAB BARS (GB-#). 9. COORDINATE EXACT PLACEMENT OF ALL CEILING DEVICES IN GYP BD CEILING EXPOSED STRUCTURE CEILING AREAS WITH ARCH PRIOR TO INSTALLATION. 10. WHERE WALL TYPE WITH GYP BD FINISH AND DIFFERENT THICKNESS JOIN IN SAME PLANE, ALIGN FACE OF GYP BD. 11. REFER TO SHEET A012 FOR TYPICAL NON-BEARING METAL STUD FRAMING DETAILS. 12. ALL DIMENSIONS ARE FROM COLUMN REFERENCE LINE TO CENTER OF STUD, UNLESS NOTED OTHERWISE. 13. PROVIDE FRT WOOD BLOCKING AT ALL TOILET PARTITIONS, GRAB BARS, AND HAND RAILS. ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A142 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTER REFLECTED CEILING PLAN LEVEL 2 SCALE: 1/4" 1'-0" A142 REFLECTED CEILING PLAN -SECOND STORY NO.DESCRIPTIONDATE
8' - 0" 8' - 0" 8' - 0" 8' - 3" 8' - 3" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 3" 8' - 3" 8' - 3" 8' - 3" 8' - 0" 8' - 0" 8' - 3" 8' - 3" 8' - 3" 8' - 3" 8' - 3" MED RECORDS 332A SCHEDULERS 332C MENS RESTROOM 336 ELEC 330 WOMEN'S RESTROOM 338 CONSULT #1 326 STAFF TOILET 324 STAFF TOILET 322 CONSULT #2 327 CONSULT #7 317 CONSULT #6 315 CONSULT #5 309 CONSULT #4 307 CONSULT #3 305 DIRECTOR 323 ADMIN ASSIST 321 EXEC ADMIN 320 ADMIN 318 WORK RM 316 LAB 314 PATIENT TOILET 311 EXAM #2 312 EXAM #1 310 SONO EXAM #3 308 SONO EXAM #2 306 SONO EXAM #1 304 WORK RM 328 CHECK-IN 335 OFFICE DIRECTOR 332D BUSINESS OFFICE 332 STAFF LOUNGE 331 RECEPTION 332E SECURED LOBBY 300 LOBBY 333 8' - 3" 8' - 0" JAN 337 NURSE PRACTITIONER 303A ELEV 8' - 3" 8' - 3" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 7' - 6" LOBBY 302 CORRIDOR 303 CORRIDOR 313 7' - 6" 7' - 6" 8' - 0" CORRIDOR 319 CORRIDOR 329 LOBBY 325 7' - 6" CORRIDOR 334 STAFF LOCKERS 331A 7' - 6" 7' - 6" 8' - 0" 8' - 0" 7' - 6" 8' - 0" 8' - 0" 1 A171 A171 2 A171 1 A171 1 A171 2 A171 2 A171 2 A171 2 A171 2 A171 2 A171 A171 2 A171 2 A171 A171 2 A171 A171 1 A171 2 A171 2 A171 ALIGN EQ EQ EQ EQ EQ EQ 7' - 6" EQ EQ 8' - 0" EQ EQ 8' - 0" EQ EQ 7' - 6" EQ EQ 7' - 6" 7' - 6" EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ 8' - 0" EQ EQ EQ EQ EQ EQ EQ EQ ALIGN EQ EQ EQ EQ A171 2 A171 2 A171 2 A171 2 A171 24" X 24" SUSPENDED ACCOUSTIC LAY-IN CLG GYP BD CLG FURRDOWN ABOVE MILLWORK AIR DEVICES (RE: MECH) REFLECTED CEILING PLAN LEGEND FLOOR LIGHT FIXTURE (RE: ELEC) FLOOR LIGHT FIXTURE (RE: ELEC) RECESSED LIGHT FIXTURE (RE: ELEC PENDANT LIGHT FIXTURE (RE: ELEC SURFACE MTD OR SUSP LIGHT FIXTURE (RE: ELEC) FLOOR LIGHT FIXTURE (RE: ELEC) GENERAL RCP NOTES 1.FIELD VERIFY ALL BULKHEAD DIMENSIONS PRIOR TO CONSTRUCTION. 2.PROVIDE CJ'S AT 30'-0" O.C. MAX AT ALL GYP BD BULKHEADS. 3.ALIGN CONTROL JOINTS (CJ'S) WITH WALLS & EDGES OF COLUMN WRAPS @ EXTERIOR PCP SOFFITS, TYP. U.O.N. 4.REFER TO MEP DOCUMENTS & COORDINATE THE LOCATIONS OF LIGHTS, DIFFUSERS, ETC., BRING ANY CONFLICTS TO THE ATTENTION OF THE ARCHITECT. GENERAL NOTES 1. REFER TO SHEET A011FOR ALL CONST KEYNOTES (#) 2. REFER TO SHEET A011 FOR ALL PARTITION TYPES 3. REFER TO SHEET A501 FOR ALL DOOR WINDOW ELEVATIONS 4. REFER TO SHEET A601 FOR ROOM FINISH LEGEND 5. REFER TO SHEET A601 FOR MATERIAL FINISH LEGEND 6. REFER TO SHEET A601 FOR EQUIPMENT SCHEDULE (EQ-#) 7. REFER TO SHEET A702 FOR FIXTURE SCHEDULE (FX-##) 8. REFER TO PROJECT MANUAL FOR ALL TOILET ACCESSORIES (TA-##) AND GRAB BARS (GB-#). 9. COORDINATE EXACT PLACEMENT OF ALL CEILING DEVICES IN GYP BD CEILING EXPOSED STRUCTURE CEILING AREAS WITH ARCH PRIOR TO INSTALLATION. 10. WHERE WALL TYPE WITH GYP BD FINISH AND DIFFERENT THICKNESS JOIN IN SAME PLANE, ALIGN FACE OF GYP BD. 11. REFER TO SHEET A012 FOR TYPICAL NON-BEARING METAL STUD FRAMING DETAILS. 12. ALL DIMENSIONS ARE FROM COLUMN REFERENCE LINE TO CENTER OF STUD, UNLESS NOTED OTHERWISE. 13. PROVIDE FRT WOOD BLOCKING AT ALL TOILET PARTITIONS, GRAB BARS, AND HAND RAILS. ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A143 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION REFLECTED CEILING PLAN LEVEL 3 SCALE: 1/4" 1'-0" A143 REFLECTED CEILING PLAN -THIRD STORY NO.DESCRIPTIONDATE
SUSPENDED ACOUSTICAL PANEL CEILING AS SCHEDULED (GYP BD WHERE NOTED) MTL STUD FRAMING CORNERBEAD, TYP. 5/8" GYP BD (PT) SUSPENDED ACOUSTICAL PANEL CEILING AS SCHEDULED (WHERE OCCURS) MTL STUD FRAMING BRACE AT 4'-0" OC (ANCHOR TO STRUCTURE) MTL DECK CONTINOUS STUD TRACK ANCHOR TO BENT PLATE MTL STUD FRAMING AT 16" OC CONTINOUS BENT PLATE BETWEEN JOISTS CEILING (REFER PLAN) CEILING (REFER PLAN) B.O. BULKHEAD (REFER PLAN) 8" MIN 8" MIN 2" MIN WALL (REFER PLANS FOR WALL TYPES) CORNERBEAD, TYP SUSPENDED ACOUSTICAL PANEL CEILING AS SCHEDULED METAL ANGLES (TYP) GYP BD, PT (TYP) MTL STUD FRAMING AT 16" OC CASEWORK DTL REFER TO PLANS OR B.O. BULKHEAD (REFER PLAN) 2" MIN WALL (REFER PLANS FOR WALL TYPES) CORNERBEAD, TYP SUSPENDED ACOUSTICAL PANEL CEILING AS SCHEDULED METAL ANGLES (TYP) GYP BD, PT (TYP) MTL STUD FRAMING AT 16" OC CASEWORK DTL REFER TO PLANS OR B.O. BULKHEAD (REFER PLAN) 2" B.O. BULKHEAD (REFER PLAN) ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A171 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION REFLECTE D CEILI NG PLA N DETAILS SCALE: 1" = 1'-0" A171 1 BULKHEAD DETAIL SCALE: 1" = 1'-0" A171 2 BULKHEAD DETAIL SCALE: 1" = 1'-0" A171 3 BULKHEAD DETAIL NO.DESCRIPTIONDATE
D23 D24 EXISTING DRAIN TO REMAIN EXISTING DRAIN TO REMAIN EXISTING DRAIN TO REMAIN EXISTING DRAIN TO REMAIN D23 1.EXISTING ROOF AND COPING SYSTEMS ARE TO REMAIN.TAKE CARE NOT TO DAMAGE 2.FOR INFORMATIONAL PURPOSES, PER EXISTING BUILDING AS-BUILT DRAWINGS PREPARED BY OTHERS THE ROOF SYSTEM CONSISTS OF GRAVEL COVER OVER 3-PLY BUILT-UP ROOF OVER GLASS FIBER FELT BASE SHEET OVER 3/4-INCH PLYWOOD DECK W/ CONTINUOUS R-30 BATT INSULATION SECURED TO BOTTOM OF DECK. 3.ALL NEW ROOF PENETRATIONS, MOUNTS, ETC, SHALL BE FULLY COMPATIBLE WITH THIS EXISTING ROOF SYSTEM AND BE INSTALLED WATERTIGHT. 4.SECURELY CAP AND SEAL ANY EXISTING VENTS AND FLUES NO LONGER IN USE, UNLESS OTHERWISE NOTED. 5.NOTIFY ARCHITECT IF ANY DAMAGED ROOF OR ROOF DECKING CONDITIONS ARE ENCOUNTERED PRIOR TO PROCEEDING WITH THE WORK. 6.PROVIDE NEW R-30 BATT INSULATION SECURED TO BOTTOM OF DECK AS REQUIRED TO INSURE CONTINOUS LAYER OF R-30 BATT INSULATION IS PROVIDED AND PROPERLY SECURED TO BOTTOM OF DECK THROUGHOUT ENTIRE EXISTING ROOF AREA ABOVE THE THIRD FLOOR. GENERAL ROOFING NOTES ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A181 10.21.22 ROOF PLAN SCALE: 1/8" 1'-0" A181 ROOF PLAN NO.DESCRIPTIONDATE
3RD FIN FLR 126' -0 1/2" 2ND FIN FLR 113' -5 7/8" TOP 141' -2" EXISTING WINDOWS TO REMAIN UNLESS OTHERWISE NOTED, TYP. 1ST FIN FLR 100' -0" 002 002 C1 TYP C2 TYP C3 TYP C2 TYP TYP C3 TYP NEW ALUM STOREFRONT, SHOWN SHADED, TYP. 3RD FIN FLR 126' -0 1/2" 2ND FIN FLR 113' -5 7/8" TOP 141' -2" EXISTING WINDOWS TO REMAIN UNLESS OTHERWISE NOTED 002 002 002 C1 TYP C2 TYP C3 TYP C2 TYP C3 TYP OPEN TO BEYOND OPEN TO BEYOND 002 TYP 002 TYP 3RD FIN FLR 126' -0 1/2" 2ND FIN FLR 113' -5 7/8" TOP 141' -2" EXISTING WINDOWS TO REMAIN UNLESS NOTED OTHERWISE 1ST FIN FLR 100' -0" 002 TYP 002 C2 C1 C3 TYP TYP C2 TYP C3 TYP TYP C2 TYP C2 C2 OPENING OPENING OPEN TO BEYOND 3RD FIN FLR 126' -0 1/2" 2ND FIN FLR 113' -5 7/8" TOP 141' -2" EXISTING WINDOWS TO REMAIN UNLESS OTHERWISE NOTED 1ST FIN FLR 100' -0" OPEN TO BEYOND 002 002 002 TYP C1 001 OPEN TO BEYOND C2 C3 TYP C2 TYP TYP C3 C1 001 001 001 C2 TYP GENERAL NOTES 1. REFER TO SHEET A011FOR ALL CONST KEYNOTES (#) 2. REFER TO SHEET A011 FOR ALL PARTITION TYPES 3. REFER TO SHEET A501 FOR ALL DOOR WINDOW ELEVATIONS 4. REFER TO SHEET A601 FOR ROOM FINISH LEGEND 5. REFER TO SHEET A601 FOR MATERIAL FINISH LEGEND 6. REFER TO SHEET A601 FOR EQUIPMENT SCHEDULE (EQ-#) 7. REFER TO SHEET A702 FOR FIXTURE SCHEDULE (FX-##) 8. REFER TO PROJECT MANUAL FOR ALL TOILET ACCESSORIES (TA-##) AND GRAB BARS (GB-#). 9. COORDINATE EXACT PLACEMENT OF ALL CEILING DEVICES IN GYP BD CEILING EXPOSED STRUCTURE CEILING AREAS WITH ARCH PRIOR TO INSTALLATION. 10. WHERE WALL TYPE WITH GYP BD FINISH AND DIFFERENT THICKNESS JOIN IN SAME PLANE, ALIGN FACE OF GYP BD. 11. REFER TO SHEET A012 FOR TYPICAL NON-BEARING METAL STUD FRAMING DETAILS. 12. ALL DIMENSIONS ARE FROM COLUMN REFERENCE LINE TO CENTER OF STUD, UNLESS NOTED OTHERWISE. 13. PROVIDE FRT WOOD BLOCKING AT ALL TOILET PARTITIONS, GRAB BARS, AND HAND RAILS. GENERAL NOTES - EXTERIOR FINISH SCHEDULE C1 = FIELD COLOR (PAINT) -COLOR TBD C2 = ACCENT COLOR #1 (PAINT) -COLOR TBD C3 = ACCENT COLOR #2 (PAINT) -COLOR TBD A.ALL EXISTING EXTERIOR METAL GUARDRAILS TO BE PAINTED -COLOR TBD B.ALL EXISTING EXTERIOR STUCCO SURFACES TO BE PAINTED COORDINATE COLOR OF ANY SURFACE NOT NOTED HEREIN W/ ARCHITECT PRIOR TO INSTALLATION. C.ALL EXISTING STUCCO SOFFITS TO BE PAINTED -COLOR TBD D.ALL EXISTING EXTERIOR WINDOW FRAMES TO BE PAINTED "C2". ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A201 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION EXTERIOR BU ILDING ELEVATIONS SCALE: 1/8" = 1'-0" A201 1 NORTH ELEVATION SCALE: 1/8" = 1'-0" A201 3 SOUTH ELEVATION SCALE: 1/8" = 1'-0" A201 4 WEST ELEVATION SCALE: 1/8" = 1'-0" A201 2 EAST ELEVATION NO.DESCRIPTIONDATE

GENERAL NOTE: REFER DETAIL A201 FOR TYPICAL BODY COLOR (C1), ACCENT COLOR (C3) AND WINDOW FRAME COLOR (C2), TYPICAL ALL ELEVATIONS THIS SHEET

3RD FIN FLR 126' -0 1/2" 2ND FIN FLR 113' -5 7/8" TOP 141' -2" 1ST FIN FLR 100' -0" 3RD FIN FLR 126' -0 1/2" 2ND FIN FLR 113' -5 7/8" TOP 141' -2" 1ST FIN FLR 100' -0" 3RD FIN FLR 126' -0 1/2" 2ND FIN FLR 113' -5 7/8" TOP 141' -2" 1ST FIN FLR 100' -0" 3RD FIN FLR 126' -0 1/2" 2ND FIN FLR 113' -5 7/8" TOP 141' -2" 1ST FIN FLR 100' -0" GENERAL NOTES - EXTERIOR FINISH SCHEDULE C1 = FIELD COLOR (PAINT) -COLOR TBD C2 = ACCENT COLOR #1 (PAINT) -COLOR TBD C3 = ACCENT COLOR #2 (PAINT) -COLOR TBD A.ALL EXISTING EXTERIOR METAL GUARDRAILS TO BE PAINTED -COLOR TBD B.ALL EXISTING EXTERIOR STUCCO SURFACES TO BE PAINTED COORDINATE COLOR OF ANY SURFACE NOT NOTED HEREIN W/ ARCHITECT PRIOR TO INSTALLATION. C.ALL EXISTING STUCCO SOFFITS TO BE PAINTED -COLOR TBD D.ALL EXISTING EXTERIOR WINDOW FRAMES TO BE PAINTED "C2". GENERAL NOTES 1. REFER TO SHEET A011FOR ALL CONST KEYNOTES (#) 2. REFER TO SHEET A011 FOR ALL PARTITION TYPES 3. REFER TO SHEET A501 FOR ALL DOOR WINDOW ELEVATIONS 4. REFER TO SHEET A601 FOR ROOM FINISH LEGEND 5. REFER TO SHEET A601 FOR MATERIAL FINISH LEGEND 6. REFER TO SHEET A601 FOR EQUIPMENT SCHEDULE (EQ-#) 7. REFER TO SHEET A702 FOR FIXTURE SCHEDULE (FX-##) 8. REFER TO PROJECT MANUAL FOR ALL TOILET ACCESSORIES (TA-##) AND GRAB BARS (GB-#). 9. COORDINATE EXACT PLACEMENT OF ALL CEILING DEVICES IN GYP BD CEILING EXPOSED STRUCTURE CEILING AREAS WITH ARCH PRIOR TO INSTALLATION. 10. WHERE WALL TYPE WITH GYP BD FINISH AND DIFFERENT THICKNESS JOIN IN SAME PLANE, ALIGN FACE OF GYP BD. 11. REFER TO SHEET A012 FOR TYPICAL NON-BEARING METAL STUD FRAMING DETAILS. 12. ALL DIMENSIONS ARE FROM COLUMN REFERENCE LINE TO CENTER OF STUD, UNLESS NOTED OTHERWISE. 13. PROVIDE FRT WOOD BLOCKING AT ALL TOILET PARTITIONS, GRAB BARS, AND HAND RAILS. ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A202 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION 1 EXTERIOR R EFINISH BUILDING EL EVATIONS SCALE: 1/8" = 1'-0" A202 1 PART EXT ELEV (WEST) SCALE: 1/8" = 1'-0" A202 2 PART EXT ELEV (EAST) SCALE: 1/8" = 1'-0" A202 3 PART EXT ELEV (EAST) SCALE: 1/8" = 1'-0" A202 4 PART EXT ELEV (WEST) SCALE: 1/8" = 1'-0" A202 5 PART EXT ELEV (EAST) SCALE: 1/8" = 1'-0" A202 6 PARTIAL EXT ELEV (SOUTH) SCALE: 1/8" = 1'-0" A202 8 PARTIAL EXT ELEV (SOUTH) SCALE: 1/8" = 1'-0" A202 7 PARTIAL EXT ELEV (WEST) PARTIAL EXT ELEV (WEST) SCALE: 1/8" = 1'-0" A202 9 PARTIAL EXT ELEV (EAST) SCALE: 1/8" = 1'-0" A202 10 PARTIAL EXT ELEV (NORTH) SCALE: 1/8" 1'-0" A202 11 PARTIAL EXT ELEV (WEST) SCALE: 1/8" = 1'-0" A202 12 PARTIAL EXT ELEV (SOUTH)
NO.DESCRIPTIONDATE

TYPICAL CLUSTER OF CONTROLS ELEVATION EXCEPTION: WHERE THERE IS SIDELITE TO THE DOOR, THEN LOCATE CONTROLS ON ADJACENT WALL CLOSEST TO DOOR,

ACOUSTICAL MATERIAL AS INDICATED ON THE PLANS, CASEWORK ELEVATIONS & INTERIOR ELEVATIONS (TYP).

TOILET PLAN GENERAL NOTES 1.REFER TO SHEETS A011 FOR WALL PARTITION TYPES, UON. 2.REFER TO SHEET A601 FOR INTERIOR FINISHES. 3.TOILET GUIDELINES: A.TOILET COMPARTMENTS -PROVIDE TOILET ACCESSORIES (TA) AT WATER CLOSETS. B.TOILET ROOM -SINGLE OCCUPANT ACCESSIBLE TOILET ROOMS SHALL RECEIVE THE SAME TOILET ACCESSORIES (TA) PROVIDED IN TYPICAL TOILETS. C.LAVATORY -PROVIDE TOILET ACCESSORIES (TA) D.SHOWER -PROVIDE ACCESSORIES FOR ACCESSIBLE SHOWER STALLS AS INDICATED FOR A "TYPICAL ACCESSIBLE SHOWER". 4.THE STRUCTURAL STRENGTH OF GRAB BARS AT ACCESSIBLE WATER CLOSETS SHALL RESIST 250 POUNDS APPLIED AT ANY POINT ON THE GRAB BAR, FASTENER, MOUNTING DEVICE, OR SUPPORTING STRUCTURE 5.COORDINATE INSTALLATION OF REQD BLOCKING AND STABILIZING FOR FIXTURES ACCESSORIES. 6.EXTEND ALL TOILET ROOM WALLS TO DECK, UON. 7.PROVIDE ACOUSTICAL BATT INSULATION IN STUD CONSTRUCTION WALLS SURROUNDING TOILET ROOMS. 8.PROVIDE WALL MOUNTED DOOR STOPS IN RESTROOMS. URINAL ACCESSIBLE URINAL MOP BASIN TOILET ROOM LEGEND REFER ACCESSIBLE MOUNTING HEIGHTS SCHEDULE SHEET FOR BALANCE OF TOILET ACCESSORY (TA) INSTALLATION REQUIREMENTS FLOOR MOUNTED WATER CLOSET FLOOR MOUNTED ACCESSIBLE WATER CLOSET LAVATORY MOP RACK (TA11) TOILET TISSUE DISPENSER (TA2) SANITARY NAPKIN DISPOSAL UNIT (TA17) - AS SCHEDULED SOAP DISPENSER(TA4) FRAMED MIRROR (TA7) PAPER TOWEL DISPENSER TOILET PARTITION EPOXY PAINT CUSTODIAL SINK 1-0 TA11 TA8 3 -0" UNLESS NOTED OTHERWISE NOTE: COORDINATE ALL ELECTRICAL ITEMS W/ CASEWORK, DISPLAY BOARDS, MIRRORS &
DOOR & FRAME DOOR HARDWARE (MEASURED FLR. TO CENTER OF HARDWARE) 40" KNOB 42" PULL HANDEL 45" PUSH PLATE 42" PANIC EXIT
CLEAR OF DOOR SWING, UNLESS NOTED OTHERWISE. GROUP & ALIGN TOP OF WALL-MOUNTED PHONES, LIGHT SWITCHES, THERMOSTATS, SPEAKER VOLUME CONTROLS, ETC. 4" TOP EDGE OF COVER 48" LIGHT SWITCH OR THERMOSTAT PUSH BUTTON CARD READER SOUND SYSTEM CALL SWITCHES AUTOMATIC DOOR SWITCH PAD FIRE ALARM PULL STATION 10" TYPICAL TACTILE CHARACTERS (703.4) WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON THE INACTIVE LEAF. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH TWO ACTIVE LEAFS, THE SIGN SHALL BE LOCATED TO THE RIGHT OF THE RIGHT HAND DOOR. FIRE EXTINGUISHER WALL MOUNT BASE OF TACTILE CHARACTERS 60" MAX 48" MIN TEXT TEXT DOOR & FRAME DOOR & FRAME LATCH SIDE DOOR & FRAME TYPICAL VISUAL CHARACTERS (703.5) TEXT 40" TO 60" TEXT 2" EXIT FIRE EXTINGUISHER CABINET OPERABLE PART 36" TOP OF BRACKET 48" MAX TYPICAL MOUNTING HEIGHTS ELECTRICAL OUTLET, TELEPHONE, AND/OR CABLE JACK. EDGE OF COVER 48" MAX M IN 15" ELECTRICAL OUTLET (GFI) IN TOILET ROOM BREAK ROOM 3 3 M IN 44" MAX CLOCK 96" SPEAKER FIRE ALARM HORN STROBE 96" MAX 80" MIN SWITCH ELECTRICAL OUTLET ABOVE BASE CABINET ELECTRICAL PANEL OR CABINET ELECTRICAL PANEL OR CABINET 72" 44" MAX40" MIN 34" FIRE VALVE CABINET 64" CHBD, MKBD & TKBD (MEASURED FLR. TO BOTT. OF BOARD) UNO 36" OPERABLE PART 42" PENCIL SHARPENER W/ 8"x8" WOOD BLOCK STANDARD 72" STANDARD HEIGHT ROBE HOOK SHELF ROD SHELF & ROD BASE OF VISUAL CHARACTERS 10" ACCESSIBLE SHELVING 36" SHELF ROD 36" CLR 60" CLR MIN EQEQ ROBE HOOK (TA5) @ 46" AFF SELF CLOSING DOOR DISPENSER (TA2) / 3 A401 SIM. ADULT TOILET ACCESSORIES (TA) TA4 SOAP DISPENSER TA7 S.S. FRAMED MIRROR (@ LAV COUNTER) TO CONTROLS 48" 40" TO BOTTOM EDGE OF REFLECTIVE SURFACE DISPENSER 48" MAX TO TA1 PAPER TOWEL DISPENSER TA3 TOWEL BAR 46" BABY CHANGING STATION TO HANDLE 43" SANITARY NAPKIN DISPENSER DISPENSER 40" TO FULL LENGTH MIRROR S.S. FRAMED MIRROR 12" 62" TO EDGE OF REFLECTIVE SURFACES ADULT TOILET ACCESSORIES (TA) TA8 S.S. SHELF 72" MAX. TA9 SHOWER CURTAIN ROD 72" MAX AS REQUIRED TA20 ELECTRIC WARM AIR HAND DRYER AIR OUTLET 48" TO TA14 PAPER TOWEL DISPENSER WASTE RECEPTACAL DISPENSER 48" TO TA11 MOP & BROOM HOLDER 72" MAX AGES 13 -ADULT ACCESSIBLE FIXTURES 15" MIN 5" MAX 27" TO SPOUT 36" MAX SPOUT 38"-43" ACCESSIBLE URINAL (605 URINALS) 15" 17" 13 1/2" MIN APRON (SHOWN HATCHED) NOTE: REQUIRED CLEAR KNEE TOE SPACE SHOWN HATCHED, TYP ACCESSIBLE AND STANDING (LO HI) ELECTRIC WATER COOLERS ACCESSIBLE ELECTRIC WATER COOLER (602 DRINKING FOUNTAINS) ACCESSIBLE WALL LAVATORY (606 LAVATORIES AND SINKS) ACCESSIBLE CABINET LAVATORY (606 LAVATORIES AND SINKS) T.O. RIM 34" INSULATE EXPOSED PIPES (TYP) 34" 27" 8" 9" 6" 11" 27" 8" 6" 11" CABINET PANEL 9" SOAP DISPENSER (TA18) AS SCHEDULED MAX 27" 4" MAX 60" CLR MIN 16" 18" LINE OF WALL FINSH WALL HUNG WC 56" CLR MIN FLOOR MOUNTED WC59" CLR MIN AT DOOR 32" CLR MIN ROBE HOOK 46" AFF (TA5) OPTIONAL LOCATION (TA17) 16" 18" SELF CLOSING DOOR 6" 6" TYPICAL ADULT WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT PLAN DETAIL TYPICAL ADULT WHEELCHAIR ACCESSIBLE WATER CLOSET PLAN DETAIL GRAB BAR (GB2) GRAB BAR (GB1) LINE OF 6" TOE CLEARANCE BEYOND FACE OF FRONT AND SIDE PARTITIONS (SHOWN DASHED) WALL HUNG WC56" CLR MIN 60" CLR MIN LINE OF CLEAR FLOOR SPACE (SHOWN DASHED) GRAB BAR (GB2) GRAB BAR (GB1) OPTIONAL LOCATION (TA17) LINE OF CLEAR FLOOR SPACE (SHOWN DASHED) DOOR PULL, BOTH SIDES, 34" -48" AFF 3 A401 / 3 A401 3 A401 / 3 A401 DELETE UNUSED DIM. STRING INSTALL ROBE HOOK (TA5) @ 46" AFF ON TOILET ROOM SIDE OF DOOR FLOOR MOUNTED WC 59" CLR MIN DELETE UNUSED DIM. STRING DISPENSER (TA2) DISPENSER (TA2) 35" 37" CLR 60" CLR MIN 32" CLR GRAB BAR (GB2) SELF CLOSING DOOR ROBE HOOK 46" AFF (TA5) TYPICAL ADULT AMBULATORY ACCESSIBLE TOILET COMPARTMENT PLAN DETAIL 17" 19" DOOR PULL, BOTH SIDES, 34" 48" AFF / 3 A401 DISPENSER (TA2) 7"-9" 54" MIN GRIPPING SURFACE 36" TOP OF 1 1/2" CLR TO OUTLET 15" MIN 39" 41" 12" 42" MIN 17"19" DISPENSER (TA2) GRAB BAR (GB2) GRAB BAR (GB9) 40" 18" GRAB BAR (GB1) 24" 12" 36" TYPICAL ADULT ACCESSIBLE WCSIDE WALL TYPICAL ADULT ACCESSIBLE WC REAR WALL FLUSH VALVE ON OPEN SIDE OF WATER CLOSET G R P P IN G S U R F A C E 36" TOP OF GRAB BAR (GB9) VERTICAL GRAB BAR GB3 AS ADOPTED BY ICC A117.1 2009, CONFIRM W/ BUILDING CODE RECEPTACLE (TA17) VERTICAL GRAB BAR GB3 AS ADOPTED BY ICC A117.1 2009, CONFIRM W/ BUILDING CODE NOTE: BOTTOM EDGE OF PARTITIONS AT 9" AFF, U.N.O EDIT ELEVATION GRAPHIC NOTES AS REQUIRED FOR PARTION NO PARTITION 42" DISPENSER (TA19) 3/8" 1 1/2" 2" 1 1/2" THINSET BEVELED MARBLE THRESHOLD VINYL FLOORING AS SCHEDULED SLOPE CERAMIC TILE FLOOR TO DRAIN 1/2" MAX 1/4" MAX 36" CLEAR FINISH FACE TO FINISH FACE 18" 22" 23" 36" CLEAR FINISH FACE TO FINISH FACE FACE OF WALL 1 1/2" 1 1/2" BACK WALL GRAB BARS (GB4) 18" SHOWER HEAD SEAT WALL CONTROL WALL 15" MAX FOLDING SHOWER SEAT 8 A401 3" MAX SLOT DRAIN, RE: PLUMB 15" 16" S L O P E T O D R A IN THRESHOLD 12" 36" W 48" CLEAR FLOOR SPACE 48" "C" MIN "D" MAX 36" 36" "A" FINISH FLOOR LINE SEAT WALL ELEVATION (OPPOSITE CONTROL WALL) CONTROL WALL ELEVATION 15" MAX CONTROL AREA 60" LONG HOSE HAND HELD SHOWER SPRAY UNIT W/ WALL MOUNT GRAB BAR (GB4) WALL MOUNTED FOLDING SHOWER SEAT HEIGHT ABOVE FINISH FLOOR MOUNTING HEIGHT A B C D ADULT 18" 36"38"46" "B" 6' 8 1/2" 3" ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A401 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION STANDA RD MOUNTING HEIGHTS A ND RESTROOM CONFIGURATIONS SCALE: 3/8" 1'-0" A401 JANITOR'S SINK SCALE: 3/8" = 1'-0" A401 4 TYPICAL MOUNTING HEIGHTS -TEMPLATE SCALE: 1/2" = 1'-0" A401 1 TYPICAL STANDARD TOILET COMPARTMENT SCALE: 1/4" 1'-0" A401 TYPICAL ACCESSIBLE TOILET ACCESSORY (TA) MOUNTING HEIGHTS -ADULT -REF. PLAN SCALE: 1/2" = 1'-0" A401 ADULT ACCESSIBLE TOILET PLANS -DETAILS SCALE: 1/2" = 1'-0" A401 3 ACCESSIBLE TOILET ELEVATIONS -ADULT -WATER CLOSETS SCALE: 1 1/2" = 1'-0" A401 TYP. ACCESSIBLE SHOWER -THRESHOLD SCALE: 1" = 1'-0" A401 TYP. ACCESSIBLE SHOWER STALL PLAN SCALE: 1/2" 1'-0" A401 ACCESSIBLE TRANSFER TYPE SHOWER ELEVATION NO.DESCRIPTIONDATE
1/4" TEMP GLASS 1/4" TEMP GLAZING HM OR PLAM DOOR FIRE RATED HM OR PLAM DOOR HM OR PLAM DOOR W/ GLASS VISION PANEL INT/EXT ALUM DOOR HM OR SCWD DOOR - W/ HALF LITE GLASS VISION PANEL T T RE: SCHED RE: SCHED RE: SCHED RE: SCHED RE: SCHED SEE SCHED. SEE SCHED. SEE SCHED. SEE SCHED. SEE SCHED. 9" 4" 2'1" 3'6" 3'0" 3'6" 6" 6" 6" 3'6" 6" 6" D5 D4 D3 D2 D1 T T DOOR SCHEDULE KEY NOTES 1. EXISTING DOOR AND FRAME TO REMAIN. FIELD VERIFY EXISTING DOOR AND FRAME DIMENSIONS. 2. REMOVE AND REPLACE DOOR HARDWARE AS SCHEDULED. 3. NEW HM DOOR TO BE INSTALLED IN NEW ALUM STOREFRONT FRAME. 4. NEW HM FRAME TO BE INSTALLED IN EXISTING PARTITION. FIELD VERIFY FRAME THROAT WIDTH AS REQUIRED TO ACCOMMODATE PARTITION. 5. BULLET-RESISTANT DOOR AND FRAME W/ LEVEL 1 BULLETRESISTANT VISION PANEL (RE: SPEC). 4' 10" FV RE: SCHED 3 A502 A502 1 A502 2ND FIN FLR 113' -5 7/8" 2" RE: SCHED 2" 1' 4" 2'11" 4' 1" 2" 5 A502 T T NOTE 1/4" TEMP GLAZING 4'4" COUNTER 2' 10" COUNTER TOP CURRENCY TRAY 13 A502 12 A502 3RD FIN FLR 126' -0 1/2" 2" 2' 8" 2" 2" AIR GAP AT JAMBS FRAME FRAME FIXED GLASS PANEL PARTITIONRE: SPEC T FACE OF WALL 7'2" 3'0" 4' 2" 7'2" 2' 0" NOTE 1. NEW ALUM IN LINE VERT LIFT SLIDING SERVICE WINDOW SYSTEM SHALL BE EQ TO MODEL IL-200- MANUAL TYPE WINDOW AS MANF BY EASISERVE (WWW.EASI-SERV.COM) 2. ANODIZED FRAME FINISH (CLEAR) 3. "NO SILL COUNTER MOUNT" OPTION. 4. CONTRACTOR TO FIELD VERIFY EXACT ROUGH OPENING (RO) REQUIREMENTS REQUIRED BY WINDOW MANUFACTURER. NOTE COUNTER TOP TO EXTEND THRU OPENING BOTH SIDES 2ND FIN FLR 113' -5 7/8" T T A502 6 A502 SIM SIM GENERAL DOOR AND WINDOW NOTES: 1. ALL DOORS WOOD TO BE 1 3/4" THICK (UON) 2. ALL STL FRAMES TO HAVE A 2" FACE DIMENSION UON, W/ 5/8" STOP. 3/4" STOP REQUIRED FOR FIRE RATED FRAMES. 3. STEEL FRAME DEPTHS INDICATED IN THE DETAILS ARE NOMINAL. PROVIDE STANDARD WIDTH FRAME WITH THROAT OPENING APPROPRIATE TO WALL TYPE. 4. EXTERIOR DOORS TO HAVE TINTED, INSULATED GLAZING (UON) AND INTERIOR DOORS TO HAVE CLEAR SAFTEY (TEMPERED) GLAZING. 5. FIELD VERIFY DIMENSIONS PRIOR TO FABRICATING FRAMES. 6. PROVIDE WD BLKG IN GYP BD WALLS BEHIND DOORS SCHEDULED TO HAVE WALL MOUNTED DOOR STOPS. (REFER HARDWARE SCHEDULE SPECIFICATION). 7. REFER TO SHEETS A012 FOR TYP WINDOW AND DOOR CONTROL JOINTS IN STEEL STUD FRAMED WALLS. 8. FLOOR MATERIAL CHANGES BETWEEN ROOMS TO OCCUR UNDER DOOR. 9. PROVIDE TREATED WOOD BLOCKING AT WINDOW SURROUND MEMBERS AS REQUIRED FOR PROPER ATTACHMENT WHERE ALUMINUM WINDOWS ARE TO BE INSTALLED IN EXISTING MASONRY OPENINGS. 3'6" 2' 8" 6'2" 4' 0" 2ND FIN FLR 113' -5 7/8" 2' 0" 2' 0" 6 A502 7 A502 1. NEW ALUM HORZ SLIDING SERVICE WINDOW SYSETM SHALL BE EQ TO MODEL SS-300-C MANUAL TYPE WINDOW AS MANF BY EASISERVE (WWW.EASISERV.COM) 2. ANODIZED FRAME FINISH (CLEAR) 3. GLASS TO BE 1/4" CLEAR TEMPERED GLASS. 4. CONTRACTOR TO FIELD VERIFY EXACT ROUGH OPENING (RO) REQUIREMENTS REQUIRED BY WINDOW MANUFACTURER. NOTE TT 4' 2" 3' 0" 6' 0" 3' 0" 3' 0" 5 A502 4 A502 3RD FIN FLR 126' -0 1/2" NOTE: 1/4" CLEAR TEMP GLAZING T T 3 A502 SIM COUNTER 3' 0" 4' 2" 2' 6" 10 A502 11 A502 3RD FIN FLR 126' -0 1/2" A502 INTEGRAL TRANSACTION SHELF W/ CURRENCY TRAY BULLET RESISTANT GLAZING SYSTEM 4' 4" 2' 10" 2" 5' 7 3/4" 2" COUNTER TOP FIXED GLASS PANEL PARTITIONRE: SPEC 3RD FIN FLR 126' -0 1/2" FRAME FRAME 12 A502 13 A502 2" AIR GAP AT JAMBS CURRENCY TRAY T FACE OF WALL 7' 2" 2' 3" FV RE: SCHED 2' 3" FV 7' 6" FV 14 A502 15 A502 2' 0" 5'2" FV RE: SCHEDULE FV 7' 2" FV T T T T NOTE: SECURITY SCREENS TO BE PROVIDED AT ALL GLAZED UNITS. THIS LOCATION RE: SPEC NOTE: TEMP INSULATED GLAZING FV 8' 10" FV 2'0" 4' 0" FV 2'0" 10" 19 A502 18 A502 16 A502 6' - 9" FV 1' - 6" 3' - 9" FV 1' 6" NOTE: SECURITY SCREENS TO BE PROVIDED AT ALL GLAZED UNITS. THIS LOCATION. RE: SPEC NOTE: TEMP. INSULATED GLAZING, TYP T T TT T T T T T FV 8' 10" FV 2'0" 4' 0" FV 2'0" 10" 3' 3" FV 19 A502 18 A502 16 A502 17 A502 NOTE: SECURITY SCREENS TO BE PROVIDED AT ALL GLAZED UNITS. THIS LOCATION. RE: SPEC NOTE: TEMP INSULATED GLAZING, TYP T T T 2ND FIN FLR 113' -5 7/8" 2'0" 2' 11 1/4" 4' 0" NOTE COUNTER TOP TO EXTEND THRU OPENING BOTH SIDES COUNTER 3' 0" RE: 6/A501 FOR ADDITIONAL NOTES TT 7 A502 6 A502 ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A501 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION DOO R SCHEDULE DOOR SCHEDULE - LEVEL 3 DOOR # FROM TO SIZE MATERIAL Rating MIN STC ELEV DETAILS KEYNOTES NUMBER NAME NUMBER NAME WIDTHHEIGHTDOORFRAME HEADJAMBTHRESH 300.0 302 LOBBY 300 SECURED LOBBY3' 0"7' 0" HM HM D32/A5023/A502 5 300.1 333 LOBBY 300 SECURED LOBBY3' 0"7' 0" HM HM D32/A5023/A502 5 304.0 303 CORRIDOR 304 SONO EXAM #1 3' 0"7' 0"PLAM HM D12/A5023/A502 305.0 303 CORRIDOR 305 CONSULT #3 3' 0"7' 0"PLAM HM D12/A5023/A502 306.0 303 CORRIDOR 306 SONO EXAM #2 3' 0"7' 0"PLAM HM D12/A50211/A501 307.0 303 CORRIDOR 307 CONSULT #4 3' 0"7' 0"PLAM HM D12/A5023/A502 308.0 303 CORRIDOR 308 SONO EXAM #3 3' 0"7' 0"PLAM HM D12/A5023/A502 309.0 303 CORRIDOR 309 CONSULT #5 3' 0"7' 0"PLAM HM D12/A5023/A502 310.0 303 CORRIDOR 310 EXAM #1 3' 0"7' 0"PLAM HM D12/A5023/A502 311.0 311 PATIENT TOILET 303 CORRIDOR 3' 0"7' 0"PLAM HM D12/A5023/A502 312.0 303ANURSE PRACTITIONER312 EXAM #2 3' 0"7' 0"PLAM HM D12/A5023/A502 314.0 313 CORRIDOR 314 LAB 3' 0"7' 0"PLAM HM D32/A5023/A502 315.0 313 CORRIDOR 315 CONSULT #6 3' 0"7' 0"PLAM HM D12/A5023/A502 316.0 313 CORRIDOR 316 WORK RM 3' 0"7' 0"PLAM HM D32/A5023/A502 317.0 313 CORRIDOR 317 CONSULT #7 3' 0"7' 0"PLAM HM D12/A5023/A502 318.0 319 CORRIDOR 318 ADMIN 3' 0"7' 0"PLAM HM D12/A5023/A502 319.0 313 CORRIDOR 319 CORRIDOR 3' 0"7' 0"PLAM HM D32/A5023/A502 320.0 319 CORRIDOR 320 EXEC ADMIN 3' 0"7' 0"PLAM HM D12/A5023/A502 320.1 321 ADMIN ASSIST 320 EXEC ADMIN 3' 0"7' 0"PLAM HM D12/A5023/A502 321.0 319 CORRIDOR 321 ADMIN ASSIST 3' 0"7' 0"PLAM HM D12/A5023/A502 321.2 323 DIRECTOR 321 ADMIN ASSIST 3' 0"7' 0"PLAM HM D12/A5023/A502 322.0 322 STAFF TOILET 319 CORRIDOR 3' 0"7' 0"PLAM HM D12/A5023/A502 323.0 319 CORRIDOR 323 DIRECTOR 3' 0"7' 0"PLAM HM D12/A5023/A502 324.0 324 STAFF TOILET 319 CORRIDOR 3' 0"7' 0"PLAM HM D12/A5023/A502 325.0 334 CORRIDOR 325 LOBBY 3' 0"7' 0"PLAM HM D32/A5023/A502 326.0 325 LOBBY 326 CONSULT #1 3' 0"7' 0"PLAM HM D12/A5023/A502 327.0 325 LOBBY 327 CONSULT #2 3' 0"7' 0"PLAM HM D12/A5023/A502 328.0 328 WORK RM 325 LOBBY 3' 0"7' 0"PLAM HM D32/A5023/A502 329.0 325 LOBBY 329 CORRIDOR 3' 0"7' 0"PLAM HM D32/A5023/A502 330.0 330 ELEC 329 CORRIDOR 3' 0"7' 0"PLAM HM D12/A5023/A502 331.0 331 STAFF LOUNGE 329 CORRIDOR 3' 0"7' 0"PLAM HM D32/A5023/A502 331A.0 334 CORRIDOR 331ASTAFF LOCKERS3' 0"7' 0"PLAM HM D12/A5023/A502 331B.0 331B CORRIDOR 333 LOBBY 3' 0"7' 0"PLAM HM D12/A5023/A502 332.0 331 STAFF LOUNGE 332BUSINESS OFFICE3' 0"7' 0"PLAM HM D32/A5023/A502 332A.0 332 BUSINESS OFFICE332A MED RECORDS 3' 0"7' 0"PLAM HM D12/A5023/A502 332C.0 331B CORRIDOR 332C SCHEDULERS 3' 0"7' 0"PLAM HM D32/A5023/A502 332D.0 331B CORRIDOR 332DOFFICE DIRECTOR3' 0"7' 0"PLAM HM D52/A5023/A502 335.0 335 CHECK-IN 334 CORRIDOR 3' 0"7' 0"PLAM HM D12/A5023/A502 336.0 334 CORRIDOR 336MENS RESTROOM3' 0"7' 0"PLAM HM D12/A5023/A502 337.0 337 JAN 334 CORRIDOR 3' 0"7' 0"PLAM HM D12/A5023/A502 338.0 334 CORRIDOR 338WOMEN'S RESTROOM3' 0"7' 0"PLAM HM D12/A502 3/A502 DOOR SCHEDULE - LEVEL 2 DOOR # FROM TO SIZE MATERIAL Rating MIN STC ELEV DETAILS KEYNOTES NUMBER NAME NUMBER NAME WIDTHHEIGHTDOORFRAME HEADJAMBTHRESH 200.0 202 PATIENT LOBBY 200 SECURED LOBBY3' 0"7' 0"PLAM HM D32/A5023/A502 200.1 237 RECOVERY 200 SECURED LOBBY 3' 0"7' 0"PLAM HM D32/A5023/A502 202.0 203 CORRIDOR 202 PATIENT LOBBY3' 0"7' 0"PLAM HM D32/A5023/A502 202.1 224 CORRIDOR 218 CORRIDOR 4' 0"7' 0"PLAM HM D32/A5023/A502 202A.0 202 PATIENT LOBBY 202A IT 3' 0"7' 0"PLAM HM D12/A5023/A502 4 202B.0 202B PUBLIC TOILET 218A CORRIDOR 3' 0"7' 0"PLAM HM D12/A502 3/A502 204.0 203 CORRIDOR 204 CONSULT 3' 0"7' 0"PLAM HM D12/A5023/A502 205.0 203 CORRIDOR 205 PROCEDURE #A4' 0"7' 0"PLAM HM D12/A5023/A502 206.0 206 RECOVERY 203 CORRIDOR 3' 0"7' 0"PLAM HM D12/A5023/A502 206.1 218 CORRIDOR 206 RECOVERY 3' 0"7' 0"PLAM HM D12/A5023/A502 207.0 203 CORRIDOR 207 PROCEDURE #B4' 0"7' 0"PLAM HM D112/A5013/A502 208.0 203 CORRIDOR 208 PROCEDURE #E4' 0"7' 0"PLAM HM D12/A5023/A502 209.0 203 CORRIDOR 209 PROCEDURE #C4' 0"7' 0"PLAM HM D12/A5023/A502 210.0 210 PATIENT TOILET 203 CORRIDOR 3' 0"7' 0"PLAM HM D12/A5023/A502 211.0 203 CORRIDOR 211 PROCEDURE #D4' 0"7' 0"PLAM HM D12/A5023/A502 212.0 212 JAN 203 CORRIDOR 3' 0"7' 0"PLAM HM D12/A5023/A502 213.0 213 WORK RM 203 CORRIDOR 3' 0"7' 0"PLAM HM D52/A5023/A502 214.0 214 CORRIDOR 218 CORRIDOR 4' 0"7' 0"PLAM HM D12/A5023/A502 215.0 214 CORRIDOR 215 SOIL WORK 3' 0"7' 0"PLAM HM D12/A5023/A502 216.0 216 DOCTOR OFFICE 218 CORRIDOR 3' 0"7' 0"PLAM HM D12/A5023/A502 217.0 214 CORRIDOR 217 CLEAN WORK 3' 0"7' 0"PLAM HM D12/A5023/A502 218B.0 218B PUBLIC TOIL 218A CORRIDOR 3' 0"7' 0"PLAM HM D12/A5023/A502 219.0 218 CORRIDOR 219 LOCKERS 3' 0"7' 0"PLAM HM D12/A5023/A502 220.0 218 CORRIDOR 220 WOMEN TOILET3' 0"7' 0"PLAM HM D12/A5023/A502 221.0 221 STAFF TOILET 218 CORRIDOR 3' 0"7' 0"PLAM HM D12/A5023/A502 222.0 222 JAN 218 CORRIDOR 3' 0"7' 0"PLAM HM D12/A5023/A502 223.0 218 CORRIDOR 223 STAFF LOUNGE3' 0"7' 0"PLAM HM D12/A5023/A502 225.0 227 CORRIDOR 225 CONSULT #1 3' 0"7' 0"PLAM HM D12/A5023/A502 226.0 227 CORRIDOR 226 CONSULT #2 3' 0"7' 0"PLAM HM D12/A5023/A502 227.0 224 CORRIDOR 227 CORRIDOR 4' 0"7' 0"PLAM HM D32/A5023/A502 228.0 228 ELEC 227 CORRIDOR 3' 0"7' 0"PLAM HM D12/A5023/A502 229.0 227 CORRIDOR 229 PROCEDURE #13' 0"7' 0"PLAM HM D12/A5023/A502 229.1 239 CORRIDOR 229 PROCEDURE #13' 0"7' 0"PLAM HM D12/A5023/A502 230.0 227 CORRIDOR 230 PROCEDURE #23' 0"7' 0"PLAM HM D12/A5023/A502 230.1 239 CORRIDOR 230 PROCEDURE #23' 0"7' 0"PLAM HM D12/A5023/A502 232.0 227 CORRIDOR 232 PROCEDURE #33' 0"7' 0"PLAM HM D12/A5023/A502 232.1 239 CORRIDOR 232 PROCEDURE #33' 0"7' 0"PLAM HM D12/A5023/A502 234.0 227 CORRIDOR 234 PROCEDURE #43' 0"7' 0"PLAM HM D12/A5023/A502 234.1 239 CORRIDOR 234 PROCEDURE #43' 0"7' 0"PLAM HM D12/A5023/A502 235.0 227 CORRIDOR 235 PROCEDURE #53' 0"7' 0"PLAM HM D12/A5023/A502 235.1 239 CORRIDOR 235 PROCEDURE #53' 0"7' 0"PLAM HM D12/A5023/A502 236.0 236 JANITOR 227 CORRIDOR 3' 0"7' 0"PLAM HM D12/A5023/A502 237.0 227 CORRIDOR 237 RECOVERY 4' 0"7' 0"PLAM HM D12/A5023/A502 237B.0 237B CLEAN SUPPLY 237 RECOVERY 3' 0"7' 0"PLAM HM D32/A5023/A502 237C.0 237C PATIENT TOILET 237 RECOVERY 3' 0"7' 0"PLAM HM D12/A502 3/A502 237D.0 237D PATIENT TOILET 237 RECOVERY 3' 0"7' 0"PLAM HM D12/A502 3/A502 237E.0 237E SOIL UTILITY 237 RECOVERY 3' 0"7' 0"PLAM HM D12/A5023/A502 238A.0 238 NURSE STATION 238A JAN 3' 0"7' 0"PLAM HM D12/A5023/A502 4 240.0 240 UTILITY 239 CORRIDOR 3' 0"7' 0"PLAM HM D12/A5023/A502 241.0 239 CORRIDOR 241 SOILED WORK 3' 0"7' 0"PLAM HM D32/A5023/A50 242.0 239 CORRIDOR 242 CLEAN WORK 3' 0"7' 0"PLAM HM D32/A5023/A502 243.0 239 CORRIDOR 243 CLEAN SUPPLY 3' 0"7' 0"PLAM HM D32/A5023/A502 244.0 239 CORRIDOR 244 EQUIP STORAGE3' 0"7' 0"PLAM HM D32/A5023/A502 1/4" = 1'-0" 4 HM DR SIDELIGHTWORK RM 213 1/4" = 1'-0" 10 FIXED GLASS PANEL PARTITION AT RECEPTION 334 1/4" = 1'-0" 5 INTERIOR WINDOWSOIL WORK 215 1/4" = 1'-0" 6 INTERIOR SLIDING WINDOWSOILED WORK 241 TO CORRIDOR 1/4" = 1'-0" 8 INTERIOR HM WINDOW -OFFICE DIRECTOR 332 1/4" = 1'-0" 11 INTERIOR BULLET-RESISTANT WINDOW SYSTEM -CHECK-IN 335 DOOR SCHEDULE - LEVEL 1 DOOR # FROMTOSIZEMATERIAL Rating MIN STC ELEV DETAILS KEYNOTES NUMBER NAME NUMBER NAME WIDTHHEIGHTDOORFRAME HEADJAMBTHRESH 105.0 - EXTERIOR - EXTERIOR 3' 0"7' 0" HM HM D1 3 106.0 - EXTERIOR 3' 0"7' 0" HM HM D1 3 1/4" = 1'-0" 9 FIXED GLASS PANEL PARTITION AT RECEPTION 322 DOOR SCHEDULE - EXISTING DOORS DOOR # FROM TO MATERIAL ELEVKEYNOTES NUMBER NAME NUMBER NAME DOORFRAME X100.0 100 LOBBY - EXTERIOR HM HM 1,2 X100.1 100 LOBBY - EXTERIOR HM HM 1,2 X100.2 100 LOBBY 101 STAIR HM HM 1,2 X101.0 101 STAIR - EXTERIOR HM HM 1,2 X102.0 102ELEVATOR EQUIPMENT ROOM - EXTERIOR HM HM 1,2 X104.0 104 FIRE RISER 103GARAGE FIRST FLOORHM HM 1,2 X105.1 - EXTERIOR - EXTERIOR HM HM 1,2 X105.2 - EXTERIOR 103GARAGE FIRST FLOORHM HM 1,2 X106.1 - EXTERIOR HM HM 1,2 X201.0 200 SECURED LOBBY 201 STAIR HM HM 1,2 X224.0 224 CORRIDOR HM HM 1,2 X301.0 300 SECURED LOBBY 301 STAIRS HM HM 1,2 X304.1 304 SONO EXAM #1 343 BALCONY WD WD 1 X321.3 321 ADMIN ASSIST 340 BALCONY WD WD 1 X329.1 329 CORRIDOR WD WD 1 X331.1 331 STAFF LOUNGE 341 BALCONY WD WD 1 X332.1 332 BUSINESS OFFICE 341 BALCONY WD WD 1 X332A.1 332A MED RECORDS 341 BALCONY WD WD 1 X333.0 333 LOBBY 342 BALCONY WD WD 1 1/4" = 1'-0" 1 NEW ALUM STOREFRONT ENTRY 1/4" = 1'-0" 3 NEW ALUM STOREFRONT BAY WINDOW 1/4" = 1'-0" 2 NEW ALUM STOREFRONT BAY WINDOW 1/4" = 1'-0" 7 INTERIOR SLIDING WINDOWSOILED 241 TO CLEAN 242 - TEMPERED NO.DESCRIPTIONDATE
GLAZING HM JAMB ANCHOR HM FRAME (REF SPEC) SEALANT ENTIRE PERIMETER TYP BOTH SIDES DBL 20 GA MIN MTL STUDS AT JAMB GYP BD (REF PART TYPE) NOTE: RE: HM FRAME WIDTH SCHED FOR DIMS "D" "C" "D" "B" "E" "E" DEPTH "A" 2" 5/8" X 5/8" HM STOPS (TYP) NOTE: RE: HM FRAME WIDTH SCHED FOR DIMS GLAZING HM FRAME (REF SPEC) SEALANT ENT PERIM TYP BOTH SIDES LIGHT GA MTL TRACK AT SILL GYP BD (REF PART TYPE) "D" "C" "D" "B" "E" "E" DEPTH "A" 2" 5/8" X 5/8" HM STOPS (TYP) ALUM FRAMED STOREFRONT SYSTEM ALUM FRAMED STOREFRONT DOOR SYSTEM REF PLAN 1 3/4" GYP BD (REF PART TYPE) SHIM AS REQ'D CONT J-MOLD (TYP BOTH SIDES) CONT SEALANT AND BACKER ROD ENT PERIMTYP BOTH SIDES STOREFRONT FRAM'G (REF SPEC) TRACK FRAMING BATT INSUL (WHERE APPLICABLE) R.O. 1/4" GYP BD (REF PART TYPE) SHIM AS REQ'D CONT J-MOLD (TYP BOTH SIDES) CONT SEALANT AND BACKER ROD ENT PERIM - TYP BOTH SIDES STOREFRONT FRAM'G (REF SPEC) BATT INSUL (WHERE APPLICABLE) R.O. DBL 20 GA MIN MTL STUDS AT JAMB 5/8" REF PLAN 5/8" 1/4" EQ EQ PLAM PAY IN DEAL TRAY (RE: SPEC) BULLET RESISANT GLAZING SHIM AS REQ'D GYPSUM WALL BOARD. RE: SPEC BLANKET INSULATION SHIM AS REQ'D CFMF TRACK CFMF GYPSUM WALL BOARD. RE: SPEC BLANKET INSULATION CORNER BEAD 5 1/2" GYP BD (REF PART TYPE) SHIM AS REQ'D CONT -MOLD (TYP BOTH SIDES) CONT SEALANT AND BACKER ROD ENT PERIM - TYP BOTH SIDES FRAM'G (REF SPEC) BATT INSUL (WHERE APPLICABLE) R.O. DBL 20 GA MIN MTL STUDS AT JAMB 5/8" 4 1/2" BULLET -RESIST PANEL GYP BD (REF PART TYPE) SHIM AS REQ'D CONT -MOLD (TYP BOTH SIDES) CONT SEALANT AND BACKER ROD ENT PERIMTYP BOTH SIDES FRAM'G (REF SPEC) TRACK FRAMING BATT INSUL (WHERE APPLICABLE) R.O. BULLET-RESIST PANEL DR (RE: DR SCHED FOR TYPE AND SWING) DR STOP BEYOND HM FRM (RE: SPEC) SEALANT ENT PERIM LT GA MTL TRACK FRM GYP BD (RE: PART TYPE) NOTE: RE: HM DR FRM WIDTH SCHED FOR DIMS 2" DEPTH "A" "D" "C" "D" "B" "E" "E" TYP INT WALL A-FRAME WIDTHB-WALL WIDTH C-STUD WIDTHD-GYP BDE-FRAME EDGE 7/16" 1/2" 1/2" 9/16" 1/2" 1/2" 1/2" 1/2" 1/2" 5/8" 5/8" 5/8" 3-5/8" 3-5/8" 6" 8" 6" 8" 9" 7" 4-5/8" 9-1/4" 7-1/4" 4-7/8" 5-3/4" 8-1/4" 10-1/4" 5-3/4" 8" 10" NOTE: 3 JAMB ANC FOR HT UP TO 7'-2" AND 4 JAMB ANC FROM 7'-3" THRU 9'-0" TYP HM FRAME WIDTH SCHED (MTL STUD WALL) DR (RE: DR SCHED FOR TYPE AND SWING) HM JAMB ANCHOR HM FRM (RE: SPEC) SEALANT ENT PERIM TYP BOTH SIDES DBL 20 GA MIN MTL STUDS AT JAMB GYP BD (RE: PART TYPE) NOTE: RE: HM DR FRM WIDTH SCHED FOR DIMS "D" "C" "D" "B" "E" "E" DEPTH "A" 2" TRANSITION UNDER DOOR FIN FLR MAT'L (RE: INTERIOR DESIGN DWGS) DOOR (REF: DR SCHED FOR TYPE AND SWING) DOOR STOP FACE OF FRAME (RE: SPEC) FIN BASE (RE: INTERIOR DESIGN DWGS) WALL BEYOND (RE: RM FIN SCHED) FIN FLR MAT'L (RE: INTERIOR DESIGN DWGS) ALUM FRAMED STOREFRONT SYSTEM NEW PREFIN MTL FLASHING CONT. BACKER RODS AND SEALANT, BOTH SIDES EXISTING DORMER CONSTRUCTION TO REMAIN NEW PREFIN MTL FLASHING EXISTING TO REMAIN (SHOWN SHADED), PATCH/REPAIR AS REQ'D FOR SCOPE OF WORK. CONT. BACKER RODS AND SEAL BOTH SIDES NEW ALUM STOREFRONT STOREFRONT SILL F.V. 4" WD SHIM NEW ALUM STOREFRONT SYSTEM CONT. SEALANT AND BACKER ROD, BOTH SIDES 2" PREFIN MTL FLASHING NOTE REFER 14/A502 FOR BALANCE OF INFORMATION STOREFRONT FRAMING NOTE MATCH EXISTING ANGLE ALUM FRAMED STOREFRONT SYSTEM DOOR (REF SPEC) GLAZING (REF SPEC) OUTSIDE FACE OF ALUM STOREFRONT BEYOND 4 1/2" TAS-ADA COMPLIANT ALUMINUM THRESHOLD SET IN FULL BED OF SEALANT 1/2" MAX 10" MIN EXISTING TO REMAING 1/2" TEMP GLASS 1"x1"x STAINLESS STEEL GLAZING CHANNEL - FINISH AS SCHED COUNTERTOP 1/2" TEMP GLASS 1"x2" STAINLESS STEEL GLAZING CHANNELFINISH AS SCHED REF PLAN REF PLAN R.O. STOREFRONT FRAM'G (REF SPEC) SEALANT AND BACKER ROD ENT PERIM TYP BOTH SIDES SHIM AS REQ'D EQ EQ REF PLAN 2" EXISTING SHOWN SHADED ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A502 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTER DOOR / WINDOW / STOREFRONT CURTAINWA LL ELEVATIONS SCALE: 3" = 1'-0" A502 5 TYP INT HM WINDOW JAMB DTL SCALE: 3" = 1'-0" A502 4 TYP INT HM WINDOW SILL DTL SCALE: 3" = 1'-0" A502 8 INT ALUM STOREFRONT DOOR JAMB/ HEAD DTL SCALE: 3" = 1'-0" A502 7 TYP INT ALUM STOREFRONT HEAD DTL SCALE: 3" = 1'-0" A502 6 TYP INT ALUM STOREFRONT JAMB DTL SCALE: 3" = 1'-0" A502 9 WINDOW SILL AT TRANSACTION WINDOW SCALE: 3" = 1'-0" A502 10 TYP INT BULLET-RESISTANT ALUM STOREFRONT JAMB DTL SCALE: 3" = 1'-0" A502 11 INT ALUM BULLET RESISTANT ALUM STOREFRONT HEAD DTL SCALE: 3" = 1'-0" A502 TYP INT HM DR HEAD DTL SCALE: 3" = 1'-0" A502 TYP INT HM DR JAMB DTL SCALE: 3" = 1'-0" A502 TYP INT DOOR THRESHOLD DTL AT FLR'G CHANGE SCALE: 3" = 1'-0" A502 18 STOREFRONT HEAD DTL SCALE: 3" = 1'-0" A502 16 STOREFRONT SILL DTL SCALE: 3" = 1'-0" A502 17 STOREFRONT JAMB DTL SCALE: 3" 1'-0" A502 19 EXT ALUM CORNER DTL SCALE: 3" = 1'-0" A502 14 EXT ALUM SF THRESHOLD DTL SCALE: 6" = 1'-0" A502 12 HERCULITE SILL DETAIL SCALE: 6" = 1'-0" A502 13 HERCULITE HEAD DETAIL SCALE: 3" = 1'-0" A502 15 EXT ALUM STOREFRONT SILL NO.DESCRIPTIONDATE
FAAP ROOM FINISH KEY C-1 PT-1 ,PT-2 WB-1 TL-1 A CEILING MATERIAL WALL MATERIAL WALL BASE MATERIAL FLOOR MATERIAL KEYNOTE ROOM FINISH SCHEDULE KEYNOTES A. ALL WALLS TO RECEIVE WALL TILE UP TO CLG. B. PAINT TO BE EPOXY TYPE. C. NO TILE AT WALLS OF FLOOR OF SHOWER. SHOWER IS A PREFAB TYPE (RE: PLUMB). D. PORCELAIN TILE WALL BASE TO BE 4" H W/ CONT SCHLUTER TRIM AT TOP. E. INSTALL FIBERGLASS REINFORCED PANEL (FRP), WHITE TEXTURED FINISH, ON ALL WALLS OF THIS ROOM. PANEL TO EXTEND FROM TOP OF WALL BASE UP TO 3'-6" AFF (RE: SPEC). F. THE PT2 TILE TO BE INSTALLED ON WALL ABOVE VANITY ONLY. PT2 TILE SHALL EXTEND FROM TOP OF VANITY UP TO BOTTOM OF CEILING ABOVE. G. ALL EXISTING METAL SURFACES INSIDE THIS ROOM(I.E. HANDRAIL, GUARDRAIL, STAIR, FRAMING, NOSING, H.M.DOOR, FRAME, ROOF HATCH LADER) THAT CURRENTLY DO NOT MATCH EXISTING WALL COLOR, TO BE PREPPED AND PAINTED P2(SEMI GLOSS) UNLESS NOTED OTHERWISE. H. ACCENT PAINT ON HEADWALL ABOVE WALL PROTECTION WP2 I. EXISTING TILE FLOOR TO REMAIN J. ALL EXISTING DOORS AND DOOR FRAMES TO BE PAINTED. K. WP2 TO EXTEND AND COVER ALL WALLS THIS ROOM UON. EXTEND OVER TO FACE OF CORNER GUARDS/ DOOR FRAMES, ETC. L. WP2 TO EXTEND FULL LENGTH OF HEADWALL THIS AREA. (REFER TO BOTTOM BOX OF ROOM FINISH TAG) FLOOR FINISH: A. ALL FLOOR TRANSITIONS ARE TO OCCUR AT THE CENTERLINE OF DOOR WHEN DOOR IS IN CLOSED POSITION, UNLESS NOTED OTHERWISE. REFER TO TRANSITION DETAILS ON THIS SHEET. WALL BASE: A. ALL RUBBER BASE SHALL BE SEALED TIGHT TO FINISHED FLOOR. WALL FINISH: A. WALLS TO HAVE LEVEL 5 FINISH UNLESS NOTED OTHERWISE. (RE: SPEC) B. TYPE "A" - EGGSHELL FINISH AND TYPE "B" SEMI GLOSS EPOXY. PAINT ALL WALLS TYPE "A", UNLESS NOTED OTHERWISE. C. PAINT ALL ELECTRICAL AND ACCESS PANEL FRAMES AND DOORS IN CORRIDORS, COLOR TO MATCH ADJACENT WALL. D. PORCELAIN TILE WALL GROUT JOINTS SHALL BE 1/8" OR LESS WITH GROUT RELEASE. E. ALL PARTIAL HT WALL TILE SHALL HAVE CONT MTL WALL CAP AT TOP EDGE. CEILING FINISH: A. FURDOWN FINISH: VERTICAL AND HORIZONTAL SURFACES OF FURDOWN TO MATCH ADJACENT WALLS, UNLESS NOTED AS ACCENT COLOR ON FINISH PLAN. B. REFER TO REFLECTED CEILING PLAN FOR ALL CEILING HEIGHTS. C. PAINT DRYWALL ACCESS PANELS IN CEILING, COLOR TO MATCH ADJACENT CEILING FINISH. DOORS/WINDOWS: A. PLAM DOOR FINISH SHALL BE PL2, UNLESS NOTED OTHERWISE. B. INTERIOR HOLLOW METAL DOOR & FRAME TO BE PAINTED: P1, UNLESS NOTED OTHERWISE. (SEMI-GLOSS) MISCELLANEOUS: A. NOT USED B. WP2 WALL COVERING TO EXTEND FROM TOP OF WALL BASE UP TO JUST BEHIND BUMPER GUARD. ROOM FINISH SCHEDULE GENERAL NOTES P1 P1 RB1STAIR ELEVATOR EQUIPMENT ROOM 102 ELEV P1 P1 RB2I,J EQUIPMENT SCHEDULE KEYNOTES A. COORDINATE EXACT LOCATION AND ROUGH-IN AT COUN TERTOP W/MILLWORK SHOP DRAWINGS. MILLWORK SHALL BE DESIGNED TO ACCOMODATE LIGHT BOX SYSTEM. B. 20"X30" HORIZ FRONT-ACCESS LED LIGHT BOX AS MANF BY DSA SIGNAGE (WWW.DSASIGNAGE.COM). TOP OF BOX TO BE FLUSH W/ TOP OF ADJACENT COUNTERTOP. LIGHT BOX SYSTEM SHALL HAVE WATERPROOF GASKETING AROUND ENTIRE PERIM. NEATLY SEAL JOINT ENTIRE PERIM BETWEEN LIGHT BOX AND COUNTERTOP. C. LIGHT SWITCH FOR LIGHT BOX TO BE MOUNTED ON FRONT OF MILLWORK. D. REFER TO SPECIFICATION OF THIS ITEM E. PROVIDE WALL BOX WATER CONNECTION FOR ICE MAKER (RE:PLUMB). F. CONTRACTOR TO SECURELY ANCHOR THIS DEVICE TO CABINET AND WALL AS REQUIRED. PROVIDE ALL NECESSARY BLOCKING. ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A601 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION COLO R SCHEDULES & DETAILS EQUIPMENT SCHEDULE EQUIP NO DESCRIPTION STATUSELECDATAPLUMBNOTES EQ-01 RECOVERY BED OF/OIYES -EQ-02 RECOVERY RECLINER OF/OI- -EQ-03 EXAM TABLE OF/OIYES -EQ-04 PORTABLE SONOGRAM OF/OIYES -EQ-05 WIRE SHELF WITH CASTERS OF/OI- -EQ-06 TROFON PORTABLE ULTRASONIC SANITIZER OF/OIYES -EQ-07 TABLETOP AUTOCLAVE OF/OIYES -EQ-08 FUTURE FULL SIZE AUTOCLAVE OF/OIYES -EQ-09 REACH IN FREEZER OF/OIYES -EQ-10 HORIZ FRONT-ACCESS LIGHT BOX CF/CIYES - - A,B,C EQ-11 METAL LOCKER CF/CI- - - D EQ-12 BLOOD DRAW CHAIR-1 OF/OI- -EQ-13 BLOOD DRAW CHAIR-2 EQ-14 PRINTER COPIER OF/OIYES YESEQ-15 REFRIGERATOR EQ-16 UNDERCOUNTER DISHWASHER OF/CIYES - YES EQ-17 TALL REFRIEDGERATOR OF/CIYES - YESE EQ-18 UNDERCOUNTER DISHWASHER (N.C.ACCESSIBLE) OF/CIYES - YES EQ-19 NARCOTICS LOCKER OF/CI- - - F EQ-20 UNDERCOUNTER REFIGERATOR OF/OIYES -SCALE: 1/4" = 1'-0" A601 1 LEVEL 1 - FINISH FLOOR PLAN NO.DESCRIPTIONDATE
FACP ACT1 P1 SV1 SV1 ACT1 P1 PT1 PT1 B, D, E ACT1 P1 RB1 SVT1 ACT1 PT1,2 PT1 PT1 A,B ACT1 PT1,2 PT1 PT1 A,B ACT1 PNT1,2 PT1 PT1 A,B ACT1 P1 RB2 SVT1 ACT1 PT1,2 PT1 PT1 A,B ACT1 P1 RB1 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 SV1 SV1 ACT1 P1 SV1 SV1 ACT1 P1 SV1 SV1 ACT1 P1 RB2 SVT1 ACT1 P1 SV1 SV1 ACT1 P1 SV1 SV1 ACT1 P1 RB1 SVT1 ACT1 P1 RB1 SVT1 ACT1 P1 SV1 SV1 ACT1 P1 SV1 SV1 ACT1 P1 RB1 SVT1 ACT1 P1 RB1 SVT1 ACT1 P1 PT1 PT1 B,D,E ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 SV1 SV1 ACT1 P1 SV1 SV1 ACT1 P1 SV1 SV1 ACT1 P1 SV1 SV1 ACT1 P1 SV1 SV1 ACT1 P1 RB2 SVT1 ACT1 P1 SV1 SV1 ACT1 P1 SV1 SV1 ACT1 P1 RB2 LVT1 ACT1 PT1,2 PT1 PT1 A,B P1 PT1,2 PT1 PT1 A,B,C ACT1 P1 RB2 SVT1 ACT1 P1 PT1 PT1 B,D, E ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1, P1 P1 RB2 SVT1 ACP1,P1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACP1 PNT1 RB1 LVT1 ACT1 P1 RB2 SVT1 ACT1 PT1,2 PT1 PT1 A,B ACT1,P1 P1 RB2 SVT1 ACT1,P1 P1 RB2 SVT1 EQUIP STORAGE 244 PROCEDURE #5 235 JANITOR 236 RECOVERY 237A PROCEDURE #4 234 CLEAN SUPPLY 243 CONTROL STATION 233 CORRIDOR 239 CLEAN WORK 242 PROCEDURE #3 232 CORRIDOR 231 CLEAN SUPPLY 237B PROCEDURE #2 230 SOILED WORK 241 PROCEDURE #1 229 UTILITY 240 CONSULT #2 226 CONSULT #1 225 ELEC 228 CORRIDOR 227 RECOVERY 237 NURSE STATION 238 PATIENT TOILET 237C PATIENT TOILET 237D JAN 238A IT 202A LOBBY 200 PROCEDURE #A 205 PROCEDURE #B 207 PROCEDURE #C 209 PROCEDURE #D 211 JAN 212 WORK RM 213 PATIENT TOILET 210 SOIL WORK 215 PROCEDURE #E 208 CORRIDOR 214 CONSULT 204 RECOVERY 206 DOCTOR OFFICE 216 CLEAN WORK 217 LOCKERS 219 WOMEN TOILET 220 STAFF TOILET 221 STAFF LOUNGE 223 JAN 222 CORRIDOR 218 CORRIDOR 224 PUBLIC TOIL 218B SOIL UTILITY 237E PUBLIC TOILET 202B PATIENT LOBBY 202 CORRIDOR 203 PT2 P1 P1 RB1STAIR 201 CC1 CC1 CC1 CC1 CC1 CC1 CC1 CC1 CC1 CC1 CC1 CC1 CC1 CC1 CC1 CC1 PL2 SSM1 PL2 SSM1 PL2 SSM1 PL2 SSM2 PL2 SSM1 PL2 SSM1 PL2 PL2 SSM1 PT2 PL2 SSM1 PL2 SSM1 PL2 SSM1 PL2 SSM1 PL2 SSM1 PL2 SSM2 PL2 SSM2 PL2 SSM2 SSM2 PL2 SSM2 PT3,PL2 SSM2 PL2 PL2 SSM1 PL2 SSM1 PL2 SSM1 PL2 SSM1 PL2 SSM1 PL2 SSM1 PL2 PL2 PL2 CC1 PT2 PT2 PT2 PT2 PT2 CC1 WP1 WP1 WP1 WP1 WP2WP2WP2WP2 WP2 WP2WP1 WP2 WP2 WP1 WP1 WP2 WP2 WP2 WP2 WP2 WP1 WP1 WP1 WP2 WP1 WP2 WP2 WP1 WP2 WP2 WP2 WP1 WP1 WP1 WP1 WP2 WP1 WP1 WP1 WP1 WP1 WP1 WP2 WP1 WP1 WP2 WP2 WP1 WP1 WP2 WP2 WP1 WP2 WP2 WP1 WP1 WP2 WP1 WP1 WP2 WP2 WP2 WP1 WP2 WP1 WP1WP2 WP2 WP1 WP2 WP2 WP1 WP1 WP2 WP1 WP2 WP2 WP2 WP2 WP1 WP1 WP1 WP2 WP2 WP2 ELEV ROOM FINISH KEY C-1 PT-1 ,PT-2 WB-1 TL-1 A CEILING MATERIAL WALL MATERIAL WALL BASE MATERIAL FLOOR MATERIAL KEYNOTE ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A602 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION ROOM FINIS H FLOO R PLANLEVE L 2 SCALE: 1/4" = 1'-0" A602 FINISH FLOOR PLAN -LEVEL 2 NO.DESCRIPTIONDATE
REF. ACT1 PT1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1,P1 PT1,2 PT1 PT1 ACT1 P1 RB1 SVT1 ACT1,P1 PT1,2 PT1 PT1 A,B ACT1 PT1 RB2 SVT1 ACT1 PT1,2 PT1 PT1 ACT PT1, 2 PT1 PT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB1 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 PT1 RB2 SVT1 ACT1 PT1,2 PT1 PT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SV1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1,P1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 PT1 PT1 B,D,E ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 PT1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 ACT1 P1 RB2 SVT1 SONO EXAM #1 304 SONO EXAM #2 306 SONO EXAM #3 308 EXAM #1 310 EXAM #2 312 NURSE PRACTITIONER 303A CORRIDOR 303 LOBBY 302 SECURED LOBBY 300 CHECK-IN 335 WORK RM 328 LOBBY 325 CORRIDOR 334 RECEPTION 332E CORRIDOR 331B OFFICE DIRECTOR 332D BUSINESS OFFICE 332 SCHEDULERS 332C STAFF LOCKERS 331A MENS RESTROOM 336 JAN 337 WOMEN'S RESTROOM 338 CORRIDOR 329 STAFF LOUNGE 331 MED RECORDS 332A DIRECTOR 323 ADMIN ASSIST 321 EXEC ADMIN 320 ADMIN 318 CORRIDOR 319 STAFF TOILET 322 STAFF TOILET 324 CONSULT #1 326 CONSULT #2 327 CONSULT #7 317 CONSULT #6 315 CORRIDOR 313 LAB 314 PATIENT TOILET 311 CONSULT #5 309 CONSULT #4 307 CONSULT #3 305 WORK RM 316 LOBBY 333 STAIRS 301 ELEC 330 P1 P1 RB1H PL2 SSM2 PL2 SSM2 PL2 SSM2 PL2 SSM2 PL2 SSM2 PL2 SSM2 PT2 PL2 PL2 PT2 CC1 CC1 CC1 CC1 CC1 PL2 SSM2 PL2 SSM2 PL2 SSM2 PL2 SSM2 PT2 PL2 SSM2 PT2 PL2 SSM2 PL2 SSM2 PL2 SSM2 PL2 SSM2 PT2 PL2 SSM2 PL2 SSM2 PL2 SSM2 PL2 SSM2 PL2 PL2 PL2 SSM2 PL2 SSM2 PL2 SSM2 P1 P2 P1 WP1 WP1 WP1 WP1 WP1 WP1 WP1 WP1 WP1 WP1 WP1 WP1 WP1 WP1 WP1 WP1 WP1 WP1 WP1WP1 WP1 WP1 WP1 WP1 WP1 WP1 WP1 WP1 ELEV ROOM FINISH KEY C-1 PT-1 ,PT-2 WB-1 TL-1 A CEILING MATERIAL WALL MATERIAL WALL BASE MATERIAL FLOOR MATERIAL KEYNOTE ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A603 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION ROOM FINIS H FLOO R PLANLEVE L 3 SCALE: 1/4" 1'-0" A603 FINISH FLOOR PLAN -LEVEL 3 P2 P1 P2 NO.DESCRIPTIONDATE
2' - 10" 2' 0" FP 7'0" 1' 0" 3' 0" 2' 0" 2'0" 4' 0" FURRDOWN 2' - 10" 1" TA1, TYP 9 A721 6 A721 1 A722 FP 2' 0" 3' - 0" 1' 6" 1" 1' 6" 3' - 0" 7'0" 1' 0" 3' 0" 2' 0" 2'0" TA1 3'8" FURRDOWN REFER 2/A604 FOR TYPICAL ACCESORIES 1 A722 9 A721 6 A721 3 A721 3' 9"1' 9"3' 0"2' 6" 1' 9" 3' 0" 1' 9" FP 2' 0" 2'0" 3'0" 7'0" 1'0" 1" 4' 0" 3'0" 1" FURRDOWN 9 A721 6 A721 3 A721 1" FP 2' 3" 2' - 3" 2' 3" FP 3' 0" 2' 0" 2'0" 7'0" 1' 0" FP 1' 9" CLR 2' - 0" EP CLR 2' 3 1/4" EQ-20 FURRDOWN NOTE: END PANEL (EP) - PLAM PANEL, TYPICAL EQ-16 A721 5 A721 3 A721 FP 2' 6" 2' 6" 2' - 6" 1' 6" FP FURRDOWN EQ-07EQ-07 EQ-07 FP 1' 0" 2' 6" 2' 6" 2' - 6" 1' 6" FP 1'0" 7'0" 3'0" 2'0" 2' 0" A721 9 A721 FP 3' 0" 3' 0" 1' 0" 3' 0" 3' 0" FP 1'0" 2' 0" 2'0" 3'0" FURRDOWN REFER 2/A604 FOR TYPICAL ACCESORIES 9 A721 6 A721 3 A721 1" 1' - 3" 2' 9" 2' 9" 1" 1' - 3" 2' 9" 2' 9" 2'0" 2' 0" 3'0" 1'0" 7' 0" FURRDOWN 9 A721 A721 6 A721 3' 6" FP 3' 6" 3' 6" FP 3' 6" 1' - 6" 3'0" 2' 0" 2'0" FP 7' 0" 1'0" KNEE SPACE KNEE SPACE FURRDOWN EQ-19 1' - 6" 8 A721 5 A721 3 A721 A721 2' 9" 2' 9" 2' 9" FP 1" 2' 9" 2' 9" 2' 9" FP 2'0" 2' 0" 3'0" 1'0" 7' 0" FURRDOWN 9 A721 6 A721 3 A721 2' 9" 2' 9" 2'0" 2' 0" 3'0" 1'0" 7' 0" 1" 2' 9" 2' 9" FURRDOWN 6 A721 3 A721 A721 3' 6" 2' 8" EQ-10 1' 6" 2' 9" 1' 6" 3 A721 FP 4' 0" FP 2'0" 2' 0" 3' 0" 1" 1' 3" 2' 0" 2' - 0" 1' 3" 1" FURRDOWN 3 A721 9 A721 1' 0" 7' 0" 1' - 9"3' 3"3' 3"3' 3"3' 3" CLR 2' 0"1' 6"EP 3' 0" EQ-16 NOTE: BASE CABINETS, THIS WALL, TO BE 2'-7" DEEP. 3 A721 6 A721 5 A721 3'0" 2' 0" 2'0" 2' 9" 3' 6" 2' 9" 2' 9" 2' 9" 2' 9" 2' 9" 2' 6" FP KNEE SPACE FURRDOWN WHEEL CHAIR STORAGE EQ-17 NOTE UPPERS, THIS LOCATION, TO BE 16" DEEP A721 A721 A721 5 A721 3'0" 2'0" 2' 0" 1" 2' 6" 2' 6" 2' 6" 1' 0" 1" 2' 6" 2' 6" 2' 6" EP FURRDOWN 6 A721 3 A721 9 A721 3' 0" 34" KNEE SPACE REFER 1/A604 FOR ADDITIONAL INFORMATION 7 A721 FP 1' 0" 2' 9" 1' 0" FP 1" 1' 3" 2' 0" 2' 0" 1' 3" 3'0" 2'0" 2' 0" 1'0" FURRDOWN 3 A721 9 A721 3' 0" 2' 0" 2'0" FP 3' 0" 3' 0" 1' 6" 1' 1" FP 3' 0" 3' 0" 1' 6" 1" 2' 6" 7'0" 1' 0" FURRDOWN 3 A721 A721 1/2" X 18" PLAM BRACE PANELSCENTER ON MULLION 3' 0" 1/2" X 18" PLAM BRACE PANELSCENTER ON MULLION KNEE SPACE, TYP 5 A721 2'0" 2' 0" 3'0" 1' 3" 2' 9" 2' 9" 7' 0" 1'0" 1' 3" 2' 9" 2' 9" 1" FURRDOWN 9 A721 3 A721 6 A721 2' 6" 2' 6" 1' 3" 2' 6" 2' 6" 1' 3" 2'0" 2' 0" 3' 0" FURRDOWN 7' 0" 1' 0" 3 A721 A721 9 A721 EQ-07EQ-07EQ-07 3'0" FP 1' - 6" 3' 3" 3' 3" 3' 3" 3 A721 243.0 3' 0" 3' 0" 3' 0" 3' 0" 1' 6" 5' 0" 2' 0" 1'0" FURRDOWN 1" 11 A721 2' 9" 3' 0" 2' 9" 5' 0" 2' 0" 1'0" FURRDOWN 11 A721 1' 0" 7'0" 2'0" 2' 0" 3' 0" 3' 0" 3' 0" 2' - 0" 3' 0" 3' 0" 2' - 0" FURRDOWN REFER 2/A604 FOR TYPICAL ACCESORIES (TA) A722 A721 6 A721 3 A721 14 A721 13 A721 OPEN TO BEYOND KNEE SPACE KNEE SPACE KNEE SPACE 1'0" 2' 6" 6" 3' 11" 1' 6" 3' 11" 1' 6" 3' 11" 1' 6" 6" 17' 3" 1/4" 16' 4" 1/4" 17' 1/2" ALIGN 14 A721 3' 6" 13 A721 OPEN TO BEYOND 9' 8" 1' 6" 6' 1" 17' 3" TILE INLAY TILE INLAY 3' 6" 16 A721 2' 9" 2' 9" 2' - 9" 2' 9" 3' 0" 2' 0" 2'0" 2' 9" 2' 9" 2' - 9" 2' 9" 1' 4" 6" 7'0" FURRDOWN A721 3 A721 9 A721 9 A721 3' 0" EP CLR 2' 0"4' 0"5' 1" FV KNEE SPACE FURRDOWN FP 3' 0" 2' 0" 4' 0" BENCH EQ?-17 EQ-18 1'0" 2' 6" 1'8" 2'10" 1' 4" 1'6" 10 A721 9 A721 7 A721 3 A721 1' 4" 2' 6" 1' 0" 2' 6" EP KNEE SPACE KNEE SPACE 40" 34" TA7 TA1 1 A721 7 A721 CLR 2' 10 7/8" 34" KNEE SPACE 7 A721 2' 0" 3' - 6" 1' 3" 2'10" 1'0" 7'0" KNEE SPACE A721 A721 2 A722 FURRDOWN 1'6" BENCH SEAT REFER PLAN PLAM SOLID SURFACE 18 A721 FP 2' 6" 2' 6" FP 2'0" 2' 0" 3'0" 1'0" 7' 0" FP 2' 6" 2' 6" FP FURRDOWN A721 3 A721 6 A721 1' 2" CLR 2' 8" 1' 2" 34" TYP KNEE SPACE 40" TYP TA7, TYP TRASH 1 A721 A721 7 A721 1' 6" 1'6" 4' 0" 3' - 0" 12 A721 1'6" 17 A721 3' 6" GENERAL NOTES 1. REFER TO SHEET A011FOR ALL CONST KEYNOTES (#) 2. REFER TO SHEET A011 FOR ALL PARTITION TYPES 3. REFER TO SHEET A501 FOR ALL DOOR WINDOW ELEVATIONS 4. REFER TO SHEET A601 FOR ROOM FINISH LEGEND 5. REFER TO SHEET A601 FOR MATERIAL FINISH LEGEND 6. REFER TO SHEET A601 FOR EQUIPMENT SCHEDULE (EQ-#) 7. REFER TO SHEET A702 FOR FIXTURE SCHEDULE (FX-##) 8. REFER TO PROJECT MANUAL FOR ALL TOILET ACCESSORIES (TA-##) AND GRAB BARS (GB-#). 9. COORDINATE EXACT PLACEMENT OF ALL CEILING DEVICES IN GYP BD CEILING EXPOSED STRUCTURE CEILING AREAS WITH ARCH PRIOR TO INSTALLATION. 10. WHERE WALL TYPE WITH GYP BD FINISH AND DIFFERENT THICKNESS JOIN IN SAME PLANE, ALIGN FACE OF GYP BD. 11. REFER TO SHEET A012 FOR TYPICAL NON-BEARING METAL STUD FRAMING DETAILS. 12. ALL DIMENSIONS ARE FROM COLUMN REFERENCE LINE TO CENTER OF STUD, UNLESS NOTED OTHERWISE. 13. PROVIDE FRT WOOD BLOCKING AT ALL TOILET PARTITIONS, GRAB BARS, AND HAND RAILS. ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A604 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION INTERIOR EL EVATIONS SCALE: 1/4" = 1'-0" A604 2 PROCEDURE #A SCALE: 1/4" 1'-0" A604 PROCEDURE #B, #C, #D SCALE: 1/4" 1'-0" A604 10 215 -SOIL WORK -EAST SCALE: 1/4" = 1'-0" A604 9 215 -SOIL WORK -SOUTH SCALE: 1/4" = 1'-0" A604 12 217 -CLEAN WORK -EAST SCALE: 1/4" = 1'-0" A604 13 217 -CLEAN WORK SCALE: 1/4" = 1'-0" A604 19 229 -PROCEDURE #1 -WEST SCALE: 1/4" = 1'-0" A604 21 233 -CONTROL STATION SCALE: 1/4" = 1'-0" A604 22 234 -PROCEDURE SCALE: 1/4" = 1'-0" A604 23 235 -PROCEDURE SCALE: 1/4" = 1'-0" A604 31 241 -SOILED WORK -EAST SCALE: 1/4" = 1'-0" A604 32 241 -SOILED WORK -NORTH SCALE: 1/4" = 1'-0" A604 33 241 -SOILED WORK -WEST SCALE: 1/4" = 1'-0" A604 24 237A -RECOVERY -EAST SCALE: 1/4" 1'-0" A604 36 242 -CLEAN WORK SCALE: 1/4" = 1'-0" A604 6 PATIENT TOILET SCALE: 1/4" = 1'-0" A604 35 242 -CLEAN WORK SCALE: 1/4" 1'-0" A604 213 -WORK RM -EAST SCALE: 1/4" = 1'-0" A604 7 213 -WORK RM -SOUTH SCALE: 1/4" = 1'-0" A604 20 PROCEDURE #2 & #3 SCALE: 1/4" 1'-0" A604 27 238 -NURSE STATION SCALE: 1/4" = 1'-0" A604 34 242 -CLEAN WORK -WEST SCALE: 1/4" 1'-0" A604 39 243 -CLEAN SUPPLY -EAST SCALE: 1/4" = 1'-0" A604 37 243 -CLEAN SUPPLY SCALE: 1/4" = 1'-0" A604 5 208 -PROCEDURE SCALE: 1/4" = 1'-0" A604 28 238 -NURSE STATION SCALE: 1/4" 1'-0" A604 29 238 -NURSE STATION SCALE: 1/4" 1'-0" A604 30 238 -NURSE STATION SCALE: 1/4" = 1'-0" A604 4 206 -RECOVERY -EAST SCALE: 1/4" = 1'-0" A604 17 223 -STAFF LOUNGE -WEST SCALE: 1/4" = 1'-0" A604 15 WOMENS TOILET SCALE: 1/4" = 1'-0" A604 25 PATIENT TOILET SCALE: 1/4" 1'-0" A604 11 216 -DOCTOR OFFICE SCALE: 1/4" = 1'-0" A604 18 223 -STAFF LOUNGE SCALE: 1/4" = 1'-0" A604 26 237E -SOIL UTILITY SCALE: 1/4" = 1'-0" A604 1 PUBLIC TOILET SCALE: 1/4" = 1'-0" A604 16 222 -JANITOR SCALE: 1/4" = 1'-0" A604 14 ACCESSIBLE BENCH NO.DESCRIPTIONDATE
34" 3' 9" 40" TA7 KNEE SPACE TA14 7 A721 1' 8" 3' 6" FP 1' 8" 3' 6" FP 2'0" 2' 0" 3' 0" 7' 0" 1'3" FURRDOWN 6 A721 A721 TA1 9 A721 3' 0" 2' 0" 2'0" FP 1' 0" 3' 0" 3' 0" 1' 6" FP FP 1' 6" 3' 0" 4' 1" CLR EP EQ-15EQ-15 FURRDOWN 7' 0" 1' 0" 6 A721 A721 3 A721 9 A721 FP 2' 6" 2' 6" 2' 6" 1" 2' 0" 2' 0" 3'0" 2' 6" 2' 6" FP 1'3" 7' 0" FURRDOWN EQ-14 NOTE:UPPER CABINETS TO BE 16" DEEP, THIS LOCATION 3 A721 A721 2'10" 2' 6" KNEE SPACE 2' - 6" 3' 9" 2' 3" KNEE SPACE 4 A721 A721 3' 9" FV FP 3'0" NOTE: 18" DEEP CABINETS, THIS LOCATION 3 A721 3' 0" FP 4' - 0" 4' 0" 1' 6" FURRDOWN 8' 0" 2' 6" KNEE SPACE A721 A721 1 A722 1/2" X 18" PLAM BRACE PANELS - CENTER ON MULLION, TYP KNEE SPACE, TYP 5 A721 2' 10" 4'4" KNEE SPACE KNEE SPACE KNEE SPACE 5' 11 3/4" 5' 11 3/4" 5' 11 3/8" 1' 2" OPEN TO BEYOND 5 A721 7'2" 2" 5' 7 3/4" 2" 2" 5' - 7 3/4" 2" 2" 5' 3/8" 2" DRYWALL HEADER, TYP FIXED GLASS PANEL, TYP. RE: SPEC KNEE SPACE 4'4" 2'10" 1' 6" 4' 5 3/4" 4' 5 3/4" 1' 6" 4' 3/8" 1' 6" KNEE SPACE KNEE SPACE 1' 2" PASS THRU TRAY, TYP 4 A721 5 A721 2' 0" 5' 0" FP 3' 0" 3' 0" 3' - 0" 3' 0" 1" FURRDOWN 9 A721 FP 3' - 0" 3' 0" 3' 0" 3' 0" 3' 0" 3' 0" 1' 0" FP 5'0" 2' 0" FURRDOWN A721 34" KNEE SPACE 40" TYP 1' 3" 2' 8" 1' 3" 1 A721 A721 A721 TA1 FP 3' 8" 3' 8" FP FURRDOWN A722 4' 0" 4' 0" 4' 0" FP 7' 0" FURRDOWN 1 A722 FP 2' 11" 2' 11" FP FP 2' 11" 2' 11" FP FURRDOWN 2' 0" 2' 0" 3'0" 1'0" 7' 0" 9 A721 6 A721 3 A721 2'0" 2' 0" 3' 0" FP 1' 3" 3' 0" 3' 0" 1' 6" FP FP 2' 3" 3' 0" 3' 0" 1' 6" FP FURRDOWN 1' 0" 7' 0" 3 A721 A721 FP 1' - 9" 3' 0" 1' 9" 2'0" 2' 0" 3' 0" FURRDOWN FP 1' - 9" 3' 0" 1' 9" FP 8' 0" A721 A721 A721 2'10" 2' 8" 2' 8" 2' 8" 3 A721 FP 1' 9" 3' 0" 2' 6" 2' 6" 2'6" 1'8" 2'10" EQ-17 EQ-18 KNEE SPACE FP1' 9"3' 0" CLR EP CLR 2' - 1"2' 10" FURRDOWN 1'3" 7' 0" 1'4" 3 A721 7 A721 A721 9 A721 10 A721 2'10" KNEE SPACE 1' 6" 2' 0" 1' 6" KNEE BRACE 4 A721 5 A721 34" KNEE SPACE 3' 6" 7 A721 2' 7" 1' 2" 2' 7" FP 2'10" KNEE SPACE KNEE SPACE 1 A721 A721 FURRDOWN FP CLR 2' 6" 1' 0" CLR 2' 6" 34" TYP 40" KNEE SPACE KNEE SPACE 1 A721 7 A721 KNEE SPACE 2'10" 2' 0" 5 A721 4' 4" 2'10" REFER PLAN PASS THRU TRAY A721 A722 6 1/2" 3' 0" FIXED GLASS PANEL, RE: SPEC GENERAL NOTES 1. REFER TO SHEET A011FOR ALL CONST KEYNOTES (#) 2. REFER TO SHEET A011 FOR ALL PARTITION TYPES 3. REFER TO SHEET A501 FOR ALL DOOR WINDOW ELEVATIONS 4. REFER TO SHEET A601 FOR ROOM FINISH LEGEND 5. REFER TO SHEET A601 FOR MATERIAL FINISH LEGEND 6. REFER TO SHEET A601 FOR EQUIPMENT SCHEDULE (EQ-#) 7. REFER TO SHEET A702 FOR FIXTURE SCHEDULE (FX-##) 8. REFER TO PROJECT MANUAL FOR ALL TOILET ACCESSORIES (TA-##) AND GRAB BARS (GB-#). 9. COORDINATE EXACT PLACEMENT OF ALL CEILING DEVICES IN GYP BD CEILING EXPOSED STRUCTURE CEILING AREAS WITH ARCH PRIOR TO INSTALLATION. 10. WHERE WALL TYPE WITH GYP BD FINISH AND DIFFERENT THICKNESS JOIN IN SAME PLANE, ALIGN FACE OF GYP BD. 11. REFER TO SHEET A012 FOR TYPICAL NON-BEARING METAL STUD FRAMING DETAILS. 12. ALL DIMENSIONS ARE FROM COLUMN REFERENCE LINE TO CENTER OF STUD, UNLESS NOTED OTHERWISE. 13. PROVIDE FRT WOOD BLOCKING AT ALL TOILET PARTITIONS, GRAB BARS, AND HAND RAILS. ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A605 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION INTERIOR EL EVATIONS SCALE: 1/4" = 1'-0" A605 4 PATIENT TOILET SCALE: 1/4" 1'-0" A605 312 -EXAM RM'S SCALE: 1/4" = 1'-0" A605 5 314 -LAB -EAST SCALE: 1/4" = 1'-0" A605 16 332 -BUSINESS OFFICE SCALE: 1/4" = 1'-0" A605 29 335 -CHECK IN -NORTH SCALE: 1/4" = 1'-0" A605 10 325 -LOBBY SCALE: 1/4" 1'-0" A605 303A -NURSE PRACTITIONER SCALE: 1/4" 1'-0" A605 303A -NURSE PRACTITIONER SOUTH SCALE: 1/4" = 1'-0" A605 20 332E -RECEPTION SCALE: 1/4" = 1'-0" A605 19 332E -RECEPTION SCALE: 1/4" = 1'-0" A605 18 332C -SCHEDULERSNORTH SCALE: 1/4" = 1'-0" A605 17 332C -SCHEDULERS -SOUTH SCALE: 1/4" = 1'-0" A605 8 322 -STAFF TOILET SCALE: 1/4" = 1'-0" A605 15 332 -BUSINESS OFFICENORTH SCALE: 1/4" = 1'-0" A605 14 332 -BUSINESS OFFICESOUTH SCALE: 1/4" 1'-0" A605 11 328 -WORK ROOM -NORTH SCALE: 1/4" = 1'-0" A605 6 316 -WORK ROOM SCALE: 1/4" = 1'-0" A605 316 -WORK ROOM SCALE: 1/4" = 1'-0" A605 12 331 -STAFF LOUNGE SCALE: 1/4" = 1'-0" A605 13 331 -STAFF LOUNGE SCALE: 1/4" = 1'-0" A605 30 335 -CHECK-IN -WEST SCALE: 1/4" = 1'-0" A605 9 324 -STAFF TOILET SCALE: 1/4" = 1'-0" A605 31 336 -MENS RESTROOM SCALE: 1/4" 1'-0" A605 32 338 -WOMENS RESTROOM SCALE: 1/4" 1'-0" A605 28 335 -CHECK-IN SCALE: 1/4" 1'-0" A605 21 334 -SERVICE WINDOW NO.DESCRIPTIONDATE
U.N.O. 4" SEE ELEVATION HINGED CABINET DOOR PULL COUNTERTOP WITH 4" BACKSPLASH WHERE SHOWN ON ELEVATION. SS MATERIAL RE: ROOM FINISH SCHEDULE 1/4" 1 1/2" HARDBOARD 1X WD RAIL (TYP) 1X CLEATS (TYP) 1X WD FRAME BOTTOM BOARD CONT SEALANT BASE AS SCHEDULED 3" 3/4" 2' 1" UNO LINE OF SIDE SPLASH WHERE APPLICABLE 2X4 WD BLOCKING TRASH CAN 9 1/2" 6" A721 19 PLAM U.N.O. 4" SEE ELEVATION ADJUSTABLE SHELVES (QTY. 2) HINGED CABINET DOOR PULL COUNTERTOP WITH 4" BACKSPLASH WHERE SHOWN ON ELEVATION. SS MATERIAL RE: ROOM FINISH SCHEDULE 1/4" 1 1/2" BOTTOM BOARD 1X WD FRAME 1X WD RAIL (TYP) 1X CLEATS (TYP) HARDBOARD CONT SEALANT 3" BASE AS SCHEDULED 3" 3/4" 2' 1" UNO 2X4 WD BLOCKING LINE OF SIDE SPLASH WHERE APPLICALBE A721 19 PLAM U.N.O. 4" SEE ELEVATION 1/4" 5 1/2" 1 1/2" HINGED CABINET DOOR ADJUSTABLE SHELF (QTY. 1) PULL DRAWER PULL COUNTERTOP WITH 4" BACKSPLASH WHERE SHOWN ON ELEVATION. SS MATERIAL RE: ROOM FINISH SCHEDULE CONT SEALANT 1X WD FRAME 1X CLEATS (TYP) 1X WD RAIL (TYP) HARDBOARD BOTTOM BOARD 1/2" DRAWER BOX ADJUSTABLE RESTS (TYP) 3/4" 3" BASE AS SCHEDULED 2' 1" UNO 3" PRE-DRILLED HOLES (TYP) LINE OF SIDE SPLASH WHERE APPLICABLE 2X4 WD BLOCKING A721 19 PLAM REMOVABLE ACCESS PANEL ATTACHED TO BLOCKING WITH Z-CLIPS LINE OF END PANEL BEYOND PROVIDE BLOCKING TO SUPPORT Z-CLIPS FOR REMOVABLE PANEL NOTE: PROVIDE MINIMUM CLEARANCE FOR REMOVAL AND INSTALLATION OF PANEL ON Z-CLIPS SEE ELEVATION 2' 3" 5 1/4" 1/4" 1 1/2" CONT SEALANT COUNTERTOP WITH 4" BACKSPLASH WHERE SHOWN ON ELEVATION. SS MATERIAL RE: ROOM FINISH SCHEDULE S.S.M. INTEGRAL SINK BASE AS SCHEDULED 3" 2' 1" UNO FIXED FRONT PANEL LINE OF SIDE SPLASH WHERE APPLICABLE 9" 11" 6" 8" A721 19 PLAM SEE ELEVATION U.N.O. 4" 3" PULL HINGED CABINET DOOR BASE AS SCHEDULED 2' 0 1/2" 1/4" 5 1/2" 1 1/2" S.S. DROP IN SINK CONT SEALANT COUNTERTOP WITH 4" BACKSPLASH WHERE SHOWN ON ELEVATION. SS MATERIAL RE: ROOM FINISH SCHEDULE 3/4" HARDBOARD 1X WD FRAME 1X CLEATS (TYP) BOTTOM BOARD 2X4 WD BLOCKING 2' 1" A721 19 PLAM U.N.O. 4" SEE ELEVATION 1/4" EQ 1/4" EQ 1/4" 1 1/2" 1'1" CONT SEALANT COUNTERTOP WITH 4" BACKSPLASH WHERE SHOWN ON ELEVATION. SS MATERIAL RE: ROOM FINISH SCHEDULE PULL 1/2" DRAWER BOX BASE AS SCHEDULED 1/2" DRAWER BOX 1X WD FRAME 1X CLEATS (TYP) 1X WD RAIL (TYP) 1/2" DRAWER BOX 1/2" DRAWER BOX BOTTOM BOARD HARDBOARD 2' 1" UNO LINE OF SIDE SPLASH WHERE APPLICABLE 2X4 WD BLOCKING 3" 3/4" A721 19 PLAM CEILING CLEAR 1' 0" SEE ELEV. SEE ELEVATION FASCIA: SEE CASEWORK SCHED. FOR MATERIAL PULL 1X CLEATS (TYP) HINGED CABINET DOOR HARDBOARD BOTTOM BOARD TOP BOARD 1/2" 1" PLAM CEILING SEE ELEV. SEE ELEVATION CLEAR 1' 0" FASCIA: SEE CASEWORK SCHED. FOR MATERIAL ADJUSTABLE SHELVES (QTY. 2) HINGED CABINET DOOR PULL HARDBOARD BOTTOM BOARD 1X CLEATS (TYP) ADJUSTABLE RESTS (TYP) PRE-DRILLED HOLES (TYP) PLAM 1' 0" HEAVY DUTY ADJUSTABLE STANDARDS ATTACHED TO STUDS OR BLOCKING, AS SHOWN ON ELEVATIONS, 32" O.C. MAX. ADJUSTABLE SHELF (QTY. 3) PLAM LINE OF CABINET BEYOND SEE ELEVATION *TYPICAL FOR COUNTERTOPS LESS THAN 48" WIDE CONT SEALANT COUNTERTOP WITH 4" BACKSPLASH WHERE SHOWN ON ELEVATION. SS MATERIAL RE: ROOM FINISH SCHEDULE GROMMETS TO BE LOCATED IN FIELD PER CLIENT'S REQUESTED LOCATION; MIN 4' -0" O.C. METAL SUPPORT ANGLE (3 SIDES) BASE AS SCHEDULED 1X CLEATS (TYP) U .N .O 4" 1 1/2" 2' 1" UNO LINE OF SIDE SPLASH WHERE APPLICABLE A721 19 CEILING END PANEL CLEAR 1' 0" SEE ELEVATION SEE ELEV. FASCIA: SEE CASEWORK SCHED. FOR MATERIAL HINGED CABINET DOOR PULL RECEPTACLE IN CABINET. (RE: ELEVATIONS) BOTTOM BOARD TOP BOARD BOTTOM BOARD 1X CLEATS (TYP) HARDBOARD 1' 4" PLAM SEE ELEVATION SEE ELEV. 1' 0 3/4" ADJUSTABLE SHELVES (QTY. 2) FASCIA: SEE CASEWORK SCHED. FOR MATERIAL 1X CLEATS (TYP) HARDBOARD PRE-DRILLED HOLES (TYP) BOTTOM BOARD TOP BOARD ADJUSTABLE RESTS (TYP) PRE-DRILLED HOLES (TYP) PLAM SSM ON COUNTER TOP AND FACE 3/4" PART BD 3/4" PART BD SSM ON TOP BOT. AND FACE OF BAND 1' 4" CERAMIC TILE BASE AS SCHEDULED REFER ELEVATION SSM ON COUNTER TOP AND FACE MTL ANGLE BRACKET 2 1/2" 4" 2 1/2" A721 19 PLAM BASE AS SCHEDULED SSM ON COUNTER TOP AND FACE WOOD BLOCKING AS REQ'D 3/4" PART BD 3/4" PART BD 3/4" PART BD PLAM 6" SSM ON COUNTER TOP AND FACE REFER ELEVATION REFER ELEVATION WD STUD FRAMING 3/4" PART BD BASE AS SCHEDULED 1X WD RAIL (TYP) 1' 4" 1/2" DRAWER BOX SSM ON TOP BOT. AND FACE OF BAND 3/4" PART BD REFER ELEVATION NOTE REFER 13/A721 FOR BALANCE OF INFORMATION CERAMIC TILE 2 1/2" 4" A721 19 PLAM SOLID SURFACE MATERIAL W/ EASED EDGES 1 1/2" 1 1/2" SUBSTRATE (TYP) GWB SOFFIT & FASCIA HPDL EXPOSED FACE SCRIBE TO SOFFIT CEILING 1" REF. ELEVATION 1/2" CASEWORK 1X CLEAT (TYP) PLAM ON 2 LAYERS OF 3/4" PART BD - ALL EXPOSED SURFACES AND EDGES (RE: RM FIN SCHED) 18" 4" FIN BASE (RE: RM FIN SCHED) EQ PLAM ON 2 LAYERS OF 3/4" PART BD - ALL EXPOSED SURFACES AND EDGES (RE: RM FIN SCHED) 1' 4" 1'6" 4" 3" 3/4" SSM ON 3/4" PART BD ON 2x FRAMING PLAM ON PART BD FIN BASE (RE: RM FIN SCHED) FABRIC-WRAPPED SEAT CUSHION ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A721 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION CASEWORK SEC TIONS (BASE, SIN K AND UPPER C ABINETS) SCALE: 1 1/2" = 1'-0" A721 1 BASE CABINET -TRASH SCALE: 1/2" = 1'-0" A721 2 BASE CABINET SCALE: 1/2" = 1'-0" A721 3 BASE CABINET SCALE: 1/2" = 1'-0" A721 7 SINK CABINET -ACCESSIBLE SCALE: 1 1/2" = 1'-0" A721 6 SINK CABINET SCALE: 1/2" 1'-0" A721 4 BASE CABINET SCALE: 1/2" = 1'-0" A721 8 CASEWORK SECTION SCALE: 1 1/2" = 1'-0" A721 9 CASEWORK SECTION SCALE: 1/2" = 1'-0" A721 12 CASEWORK SECTION SCALE: 1 1/2" = 1'-0" A721 BASE CABINET SCALE: 1 1/2" = 1'-0" A721 10 CASEWORK SECTION SCALE: 1 1/2" = 1'-0" A721 11 CASEWORK SECTION SCALE: 1 1/2" = 1'-0" A721 13 CASEWORK SECTION -NURSE STATION SCALE: 1 1/2" = 1'-0" A721 16 CASEWORK SECTION -NURSE STATION SCALE: 1/2" 1'-0" A721 14 CASEWORK SECTION -NURSE STATION SCALE: 3" 1'-0" A721 19 SSM EASED EDGE PROFILE SCALE: 1/2" = 1'-0" A721 15 TYPICAL CASEWORK FACIA DETAIL SCALE: 1/2" = 1'-0" A721 17 CASEWORK SECTION SCALE: 1/2" 1'-0" A721 18 CASEWORK SECTION NO.DESCRIPTIONDATE
CEILING SEE ELEVATION SEE ELEV. EQ EQ U.N.O. 4" 3" CLEAR 2' 0" FASCIA: SEE CASEWORK SCHED. FOR MATERIAL HINGED CABINET DOOR ADJUSTABLE SHELVES (QTY. 5) FIXED SHELF PULL BASE AS SCHEDULED TOP BOARD BOTTOM BOARD HARDBOARD 1X CLEATS (TYP) 1X CLEATS (TYP) 1X CLEATS (TYP) HARDBOARD PRE-DRILLED HOLES (TYP) ADJUSTABLE RESTS (TYP) 3/4" PLAM CEILING FASCIA: SEE CASEWORK SCHED. FOR MATERIAL ADJUSTABLE SHELVES (QTY. 3) PULL FIXED SHELF RECESSED FLUSH ADJUSTABLE STANDARDS (RE: SPEC) BASE AS SCHEDULED SEE ELEVATION SEE ELEV. EQ EQ 3/4" U.N.O. 4" 3" HINGED CABINET DOOR PLAM EQ EQ 8" 3/4" PART BD GYPSUM WALL BOARD. RE: SPEC CORNER BEAD PAY-IN DEAL TRAY SSM COUNTER BULLET RESISTENT GLAZING SYSTEM WD BLOCKING CFMF 6 1/2" SECURE SIDE PUBLIC SIDE ISSUE DATE PROJECT NO. SHEET NO. REVISIONS THIS DRAWING IS THE PROPERTY OF BOYNTON WILLIAMS & ASSOCIATES. THE DRAWING(S) OR INFORMATION DEPICTED SHALL NOT BE REPRODUCE D OR USED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT D22012 A722 10.21.22 SYC A MORE SQU A RE MEDIC A L CENTERA LTER A TION / RENOV A TION CASEWORK SEC TIONS (TALL CABINETS & MISC DETAILS) SCALE: 1 1/2" = 1'-0" A722 1 CASEWORK SECTION SCALE: 1/2" = 1'-0" A722 2 CASEWORK SECTION SCALE: 3" = 1'-0" A722 3 WINDOW SILL AT EXCHANGE DESK NO.DESCRIPTIONDATE

Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.