BURNERS
2014
A complete range of burners for all fuels MONOBLOCK 20 - 17000 kW DUOBLOCK 350 - 25000 kW
LIGHT OIL BURNERS
HEAVY OIL BURNERS
GAS BURNERS
GAS/LIGHT OIL BURNERS
GAS/HEAVY OIL BURNERS
DUOBLOCK BURNERS
Customised solutions for all types of application
www.ecoflam-burners.com
INDEX
COMPANY PROFILE BURNER APPLICATIONS
4 4
RANGE OF PRODUCTS Designation ECOFLAM range - modular delivery system
5 8 10
BURNER STRUCTURE Gas train composition - EN676 configurations and export Gas train - Kit - Accessories assembly to the burner Electronic version with Burner Management System TS range - Duoblock burners
12 14 15 16 16
LIGHT OIL BURNERS MAX MAIOR
18 19 21
HEAVY OIL BURNERS MAXFLAM OILFLAM Forced oil preparation ring
23 24 24 26
GAS BURNERS MAX GAS BLU
27 28 33
DUAL FUEL BURNERS (GAS/LIGHT OIL) MULTICALOR
41 43
DUAL FUEL BURNERS (GAS/HEAVY OIL) MULTIFLAM
48 49
GAS TRAIN - KITS - ACCESSORIES Gas train: MAX GAS Gas train and connection pipe: BLU - MULTICALOR - MULTIFLAM Kit and accessories for gas Kit and accessories for oil Diagnostic tool for Thermowatt control Load controller and probes Silencer
52 52 53 54 56 56 57 57
BURNER SELECTION FORM
58
www.ecoflam-burners.com
3
COMPANY PROFILE ECOFLAM Bruciatori S.p.A. is a specialist in combustion technologies and a worldwide brand recognised for the reliability of its burners, the competence of its technical team and the wide offer of customised solutions for heating and industry applications.
ECOFLAM was established in 1973 in Castelfranco Veneto, near Venice in the North East of Italy. Throughout the time ECOFLAM has continued to develop products with constant devotion and determination addressing: Technological Research, Ecology, Energy Saving and Safety. ECOFLAM Bruciatori S.p.A. since 2005 has been incorporated into the Burners Division of Ariston Thermo Group and today takes advantage of the group synergies and offers a full range of blown air pressure jet burners for all fuels in monoblock and duoblock version up to 25 MW. ECOFLAM burners ensure high efficiency and reliable operation combined with functional features that reduce installation time and maintenance. Manufacturing is carried out in the factory of Resana (Treviso - Italy) in accordance with ISO 9001:2008 and products are distributed worldwide thanks to its network of partners.
BURNER APPLICATIONS
4
HEATING APPLICATIONS
AGRICULTURE APPLICATIONS
METAL INDUSTRY APPLICATIONS
FOOD INDUSTRY APPLICATIONS
ASPHALT PLANTS AND BUILDING INDUSTRY APPLICATIONS
TEXTILE, GLASS AND CERAMIC INDUSTRY APPLICATIONS
INCINERATORS APPLICATIONS AND WASTE INDUSTRY
CHEMICAL AND PETROLCHEMICAL INDUSTRY APPLICATIONS
MODERNISATION OF PLANTS AND OTHER APPLICATIONS
WOOD AND SOLID FUEL APPLICATIONS
www.ecoflam-burners.com
RANGE OVERVIEW LIGHT OIL RANGE MAX 1
18 41
MAX 1 Low NOx
18
MAX 4
20
MAX 4 Low NOx
23
36 59 47
MAX 8
105
47
MAX 12
130
60
MAX 15
190
73
MAX 20
237
86
MAX 30
110
MAX P 12
319
130
60
MAX P 15
190
77
MAX P 25
102
300
MAX P 35
166
427
MAX P 45
202
0
100
MAIOR P 60
546
200
300
400
500
600 kW
415 710
MAIOR P 80
474
949
MAIOR P 120
830
MAIOR P 150.1
1423
592
MAIOR P 200.1
1780 710
2372
MAIOR P 300.1
1000
3000
MAIOR P 400.1
1300
MAIOR P 500.1
3900 1578
MAIOR P 600.1
5000 1795
0
1000
MAIOR P 700.1
2417
MAIOR P 800.1
5800
2000
3000
4000
5000
7500
2750
MAIOR P 1000.1
8500 3300
10500
MAIOR P 1200.1
4367
MAIOR P 1500.1
12500 5000
15000
MAIOR P 1800.1
5700
0
6000 kW
2000
4000
17000
6000
8000
10000
12000
14000
16000
18000
20000 kW
HEAVY OIL RANGE MAXFLAM 10
68
136
MAXFLAM 20
108
227
MAXFLAM 30
170
340
MAXFLAM 30 AB
205
MAXFLAM 50 AB
410
205
0
OILFLAM 80.1
100
570
200
300
400
500
600 kW
464 930
OILFLAM 120.1
682
OILFLAM 170.1
682 1700
OILFLAM 200.1
682
OILFLAM 300.1
1395
2093 1000
OILFLAM 400.1
3000
1300
OILFLAM 500.1
3900
1578
OILFLAM 600.1
5000
1795
OILFLAM 700.1
5800 2417
OILFLAM 800.1
7500
2750
OILFLAM 1000.1
8500 3300
OILFLAM 1200.1
10500 4367
OILFLAM 1500.1
12500 5000
OILFLAM 1800.1
15000 5700
0
2000
4000
6000
17000
8000
10000
12000
14000
16000
18000
20000 kW
www.ecoflam-burners.com
5
GAS RANGE MAX GAS 40
17
48
MAX GAS 70
34
70
MAX GAS 105
49
MAX GAS 120
49
MAX GAS 120 AB
108 120
40
120
MAX GAS 170
55
MAX GAS 250
55
170 240
MAX GAS 350
350
100
MAX GAS 500
500
120
0
100
BLU 700.1 low NOx
200
270
BLU 1000.1
300
875
260
BLU 1200.1 low NOx
1200
290
BLU 1500.1 low NOx
1100
300
0
BLU 1700.1
200
342
BLU 2000.1
600
800
1000
1200
1400
1600
1800
2000 kW
2150
630
BLU 4000.1
1550
400
1770
414
BLU 3000.1
600 kW
970 280
BLU 1200.1
500
700
245
BLU 1000.1 low NOx
400
3000
875
BLU 5000.1
3900 5000
1200
BLU 6000.1
1500
BLU 7000.1
1500
BLU 8000.1
5800 7500 2000
8500
BLU 10000.1
2500
BLU 12000.1
10500
2700
13000
BLU 15000.1
3690
BLU 18000.1
15000
4000
0
2000
17000
4000
6000
8000
10000
12000
14000
16000
18000
20000 kW
1400
1600
1800
2000 kW
18000
20000 kW
DUAL FUEL (GAS/LIGHT OIL) RANGE MULTICALOR 45 AB
190
500
MULTICALOR 70 AB
250
MULTICALOR 70 PR-AB
700
190
700
MULTICALOR 100 AB
300
MULTICALOR 100 PR-AB
1000
200
1000
MULTICALOR 140 AB
400
MULTICALOR 140 PR 0
MULTICALOR 170.1
200
342
MULTICALOR 200.1
MULTICALOR 600.1
1500
MULTICALOR 700.1
1500
1200
5000 5800 7500 2000
MULTICALOR 1000.1
8500 2500
MULTICALOR 1200.1
10500
2700
MULTICALOR 1500.1
13000 3690
MULTICALOR 1800.1
15000
4000
0
www.ecoflam-burners.com
1000
3900
1200
MULTICALOR 800.1
800
3000
875
MULTICALOR 500.1
600
2150
630
MULTICALOR 400.1
1300
400
1770
414
MULTICALOR 300.1
6
1300
250
2000
4000
17000
6000
8000
10000
12000
14000
16000
DUAL FUEL (GAS/HEAVY OIL) RANGE MULTIFLAM 200.1
414
MULTIFLAM 300.1
2150
630
MULTIFLAM 400.1
3000
875
MULTIFLAM 500.1
3900
1200
5000
MULTIFLAM 600.1
1500
MULTIFLAM 700.1
1500
MULTIFLAM 800.1
5800 7500 2000
MULTIFLAM 1000.1
8500 2500
MULTIFLAM 1200.1
10500
2700
MULTIFLAM 1500.1
13000 3690
MULTIFLAM 1800.1
15000
4000
0
2000
17000
4000
6000
8000
10000
12000
14000
16000
18000
20000 kW
DUOBLOCK RANGE Note: "Oil"/"Gas" indicates the output range for light oil, heavy oil, gas and dual fuel burners. PLATFORM 260 Min VSD
Min kW
Max kW
Oil 120
300
450
1400
Gas 1500.1
250
300
1550 0
1000
2000
3000
4000
5000 kW
0
1000
2000
3000
4000
5000 kW
0
1000
2000
3000
4000
5000 kW
0
3000
6000
9000
12000
15000 kW
0
3000
6000
9000
12000
15000 kW
0
5000
10000
15000
20000
25000 kW
0
5000
10000
15000
20000
25000 kW
PLATFORM 280 Min VSD
Min kW
Max kW
Oil 200.1
500
710
2372
Gas 2000.1
350
414
2150
PLATFORM 320 Min VSD
Min kW
Max kW
Oil 400.1
700
875
3900
Gas 4000.1
500
875
3900
PLATFORM 380 Min VSD
Min kW
Max kW
Oil 600.1
1050
1500
5800
Gas 6000.1
725
1500
5800
PLATFORM 630 Min VSD
Min kW
Max kW
Oil 800.1
1600
2000
8500
Gas 8000.1
1050
2000
8500
Oil 1200.1
2400
2700
13100
Gas 12000.1
1600
2700
13100
PLATFORM 710 Min VSD
Min kW
Max kW
Oil 1800.1
3200
5700
17000
Gas 18000.1
2100
4000
17000
PLATFORM 800 Min VSD
Min kW
Max kW
Oil 2500.1
5000
7000
25000
Gas 25000.1
3200
6000
25000
www.ecoflam-burners.com
7
BURNER DESIGNATION BLU 1200.1 LN PAB TL SGT 230-50 TW RANGE NAME BY FUEL TYPE MAX GAS BLU MAX MAIOR MAXFLAM OILFLAM MULTICALOR MULTIFLAM
Gas natural - LPG Gas natural - LPG Light oil Light oil Heavy oil (max visc. 50°E at 50°C) Heavy oil (max visc. 50°E at 50°C) Dual fuel: gas/light oil Dual fuel: gas/heavy oil (max visc. 50°E at 50°C)
RANGE NAME + TS
Duoblock burner
MODEL SIZE (gas: kW; oil: kg/h) MAX 4 MAIOR 120 MAX GAS 40 BLU 1200.1 MULTICALOR 300.1
4 kg/h 120 kg/h 40 kW 1200 kW 300 kg/h - 3000 kW
EMISSIONS LN - Low NOx MAX Low NOx MAX MAIOR
Low NOx Class 3 - Gas EN676 (<80 mg/kWh) Standard Class 2 - Gas EN676 (<120 mg/kWh) Low NOx Class 3 yellow flame (<120 mg/kWh) Standard Class 2 - Oil EN267 (<185 mg/kWh) Standard Class 1 - Oil EN267 (<250 mg/kWh)
OPERATION TYPE R P PAB P 120 AB P 120 AB HS Z3 / S3 PR PR-PAB MD E
1 stage 1 stage with pre-heater 1 stage - soft start 2 stages gas - soft start 2 stages light/heavy oil 120 kg/h - soft start 2 stages oil hydraulic system 120 kg/h - soft start 2 stages with 3 nozzles / 3 stages with 3 nozzles 2 stages progressive mechanical 2 stages progressive mechanical gas / 2 stages oil 2 stages modulating mechanical with PID 2 stages modulating electronic
HEAD TYPE TC TL
Short head Long head
FUEL LPG BIOGAS KER B10
Gas / Light oil / Heavy oil Liquid gas Biogas Kerosene Biodiesel
ELECTRICAL POWER SUPPLY 230-50 230-50-60 230-400-50 110-50-60
230 V, 50 Hz 230 V, 50-60 Hz 230/400 V, 50 Hz 110 V, 50-60 Hz
ELECTRICAL EQUIPMENT (CONTROL BOX) TW LFL.../LAL.../LGK... LMV... ETO BT3
8
Thermowatt Siemens Siemens electronic Lamtec Etamatic OEM Lamtec BT300
www.ecoflam-burners.com
CONFIGURATION / ADDITIONAL INFO HT D SGT NS
High temperature D pump version for light oil (max visc. 5°E at 20°C) Separate gas train Without silencer
GAS TRAIN DESIGNATION GT - S2 - VGD40 - DN80 - BLU/MULTI GAS TRAIN VALVE MANUFACTURER D K S H B
Dungs Kromschröder Siemens - Landis Honeywell Brahma
OPERATION TYPE 1 2 3 4 5
1 stage or 2 stages with butterfly valve 2 stages solenoid valve 2 stages pneumatic 2 stages electronic 2 stages mechanical
MODEL TYPE MBC120 MBDLE403 MBZRDLE410 VGD20503 VCS240 EG12L
MultiBloc model MBC120 MultiBloc model MBDLE403 MultiBloc 2 stages valve model MBZRDLE410 Siemens Landis model VGD20503 Kromschröder model VCS240 Brahma model EG12L
VALVE NOMINAL DIAMETER RP15 RP20 RP25 RP32 RP40 RP50 DN40 DN50 DN60 DN80 DN100 DN125
Rp. 1/2" Threaded connection Rp. 3/4" Threaded connection Rp. 1" Threaded connection Rp. 1"1/4 Threaded connection Rp. 1"1/2 Threaded connection Rp. 2" Threaded connection DN40 Flanged connection DN50 Flanged connection DN60 Flanged connection DN80 Flanged connection DN100 Flanged connection DN125 Flanged connection
GAS TRAIN MATCHING BURNER MAXGAS40-120 BLU/MULTI MAXGAS40-120SX
Model matching MAX GAS 40-120 Model matching BLU-MULTICALOR-MULTIFLAM range Left side connection for MAX GAS 40-120
KIT AND ACCESSORIES DESIGNATION KITTC-VPS504VCS
Kit tightness control VPS504 for VCS gas valve
PROBE-WATER130C
Water probe up to 0÷130° С
GTCP-DN80-260/280/320 OPT / STD / ACS
Connection pipe for gas train DN80 platform 260/280/320 Optional / Standard / Accessory
www.ecoflam-burners.com
9
ECOFLAM RANGE ECOFLAM burners have been designed and built in compliance with all current regulations and directives. All burners comply to the safety and energy saving operation regulations within the standard of their respective performance range. The quality is guaranteed by a quality and management system certified in accordance with ISO 9001:2008.
ISO9001:2008
COMPONENT TYPE CB BBCH BB CH GTCP GT SV
Complete Burner (for light oil or heavy oil) Burner Body with Combustion Head (without gas train) Burner Body Combustion Head Gas Train Connection Pipe Gas Train (delivered separately) Separate Ventilator for duoblock burner
GAS BURNERS AND DUAL FUEL BURNERS ECOFLAM gas and dual fuel burners are delivered in compliance with the applicable standards. Gas train is delivered separately with different configurations. Kits and accessories shall be included in the gas train and in the burner as described in the scope of supply in accordance with the instructions and the local safety regulations and codes of practise.
All gas burners are delivered in separate set/box, i.e. burner body including combustion head and separate gas train with separate additional kits and accessories, that shall complete the gas train or the burner according to the applicable standard. Kits and accessories are delivered separately. All dual fuel burners are delivered in separate set/box, i.e. burner body including combustion head and separate gas train with separate additional kits and accessories, that shall complete the gas train or the burner according to the applicable standard. Kits and accessories are delivered separately. Configurated and special versions on request with burner selection form.
GAS TRAIN - GTCP - KITS - ACCESSORIES All gas and dual fuel burners gas trains are delivered separately in different models and configurations. Export configuration gas train completion are available but it is mandatory for the local installer in this case to comply to the local safety regulations. For burners over 1700 kW gas train connection pipe must be ordered. Kits and accessories are managed and delivered separately.
10
www.ecoflam-burners.com
LIGHT OIL AND HEAVY OIL BURNERS ECOFLAM oil burners are delivered in compliance with the applicable standards. Additional accessories and options shall be installed by the installer in accordance with the instruction and the local safety regulations and codes of practise.
All light oil burners are delivered complete in one single package, including filter and flexible hoses up to 6 MW. All heavy oil burners are delivered with electrical pre-heater preassembled into the burner body, including filter and flexible hoses up to 6 MW. Configurated and special versions on request with burner selection form.
DUOBLOCK BURNERS ECOFLAM offers selected models/outputs in duoblock version for all the fuels that can be delivered based on the configuration requested (mechanical or electronic) by the customer in order to better fit into the application, providing a customised and more cost effective solution.
BURNER SELECTION: the selection of the type of operation and configuration must be done by professional personnel, in order
! to grant the correct working of the burner. Installation, start-up and maintenance must be carried out by authorised specialists and all applicable guidelines and regulations (including local safety regulations and codes of practise) must be observed.
www.ecoflam-burners.com
11
BURNER STRUCTURE
BURNER COMPOSITION - SCOPE OF SUPPLY FOR ALL BURNERS INCLUDES THE FOLLOWING PARTS:
BBCH
BURNER BODY with COMBUSTION HEAD
GTCP
GAS TRAIN CONNECTING PIPE
GT
GAS TRAIN SEPARATE * Export configuration EN676 completion * Minimum working pressure = Pressure drop inlcudes “COMBUSTION HEAD + GAS TRAIN + GAS GOVERNOR & FILTER” as per EN676
Light oil Heavy oil
BBCH is delivered in one single box Additional KIT-ACS to be ordered and delivered separately
Gas Dual fuel
BBCH - GT - ACS are delivered in separate boxes Additional KIT-ACS to be ordered and delivered separately
Duoblock
BBCH - GT - ACS are delivered in separate boxes SV and additional KIT-ACS to be ordered and delivered separately
Electronic version with BMS
BBCH - GT - ACS are delivered in separate boxes Available from 2 MW with loosen electrical panel or separate electrical or switch cabinet
Gas train size vs Diameter of the connection
To be included from the platform 280 (≈1700 kW)
MultiBloc MB
Gas MultiBloc Dungs: compact double solenoid valve with integrated filter, regulator and minimum pressure switch
Siemens VGD
Double gas valve with actuators and regulator VGD Siemens and minimum pressure switch + ACS gas filter Default blank spring: head pressure 0...22 mbar WARNING: from BLU 3000.1 - MULTICALOR 300.1 MULTIFLAM 300.1 change spring and damping
Kromschröder VCS
Double solenoid valve VCS Kromschröder and minimum pressure switch + ACS gas governor & filter
Export configuration
Export completion gas train depending on the models shall be completed in compliance with local safety regulations.
FGDR / FS1B
WARNING: size and fitting depend on the burner and the gas train selected
Gas pressure governor and filter model FGDR, operating pressure range up to 500 mbar FS1B up to 1 bar
GAS GOVERNOR & FILTER
SPRING FGDR
FGDR: default spring is neutral for outlet pressure range 10-30 mbar For different outlet setting range please change the spring according to our technical documentation
FILTER
Gas filter to complete VGD gas trains, operating pressure up to 1 bar (suggested as additional for all installations)
GAS FILTER
12
www.ecoflam-burners.com
KIT, ACCESSORIES AND CONFIGURATIONS: DIAGNOSTIC TOOL
KITDT-TW
Diagnostic tool for Thermowatt control box
TIGHTNESS CONTROL
KITTC-...
Gas leakage control device for gas trains Available in different models depending on the type of the gas train Compulsory for EN676 over 1200 kW â&#x20AC;&#x201C; 1032000 kcal/h
MAXIMUM GAS PRESSURE SWITCH
KITPRES...
Maximum gas pressure switch To be installed in order to comply with the local safety regulations
ADDITIONAL KITS ACCESSORIES
KIT - ACS
Additional kits and accessories to be installed in order to comply with the local safety regulations
For full modulating version: BURNER BODY PR + PID REGULATOR and PROBE PID CONTROLLER
KITMD-...
KITMD-RWF50 Modulation of burner can be done also from the PID of the boiler panel
MATCHING PROBE
PROBE-...
Matching probe for hot water, air, steam
Additional kits and accessories KITSIL-...
Silencer is complementary and can be ordered as a separate KIT Kit available starting from platform 260
KITLPG-...
LPG transformation kit for gas burner (see related models and technical documentation for operating gas pressure)
KITADAPT-...
Adaptor for gas train connection MAX GAS range for LPG
KITPOT-... KITxx-...
Potentiometer
ACS
Antivibration coupling
ACS
Ball valve
ACS
Manometer + Push button
ACS ACS
Magnetic + Selfcleaning oil filter
KITS
Other kits: see related pages
ACCESSORIES
Other ACS: see related pages
FLEXSHOP Configurations - Service
Configurations can be implemented in the factory from our internal FLEXSHOP
Swirl system
Swirls for blast tube that can reduce flame lenght up to 10-50%, depending on fuel, backpressure and shape of combustion chamber Available for different fuel burner head
KITCV Continuous Ventilation
Available for different burner Kit for burner with Thermowatt control box
Other
Special configurations will be evaluated on request
AFTER SALE SERVICE CONTRACTS
ECOFLAM Service Department can offer start up service contracts
SPARE PARTS
ECOFLAM original spare parts
www.ecoflam-burners.com
13
GAS TRAIN COMPOSITION - EN676 CONFIGURATION AND EXPORT ECOFLAM gas trains are delivered separately for all gas and dual fuel burners and are available in different configurations and models: • EN676 standard gas train + kit/accessories in compliance with EN676; • Export configuration + others additional options to be added by installer in compliance with local safety regulations and codes of practise; • kit and accessories shall be fitted by the installer in accordance with the instructions and the local safety regulations and codes of practise. PRESSURE DROP includes: “COMBUSTION HEAD + GAS TRAIN + GAS GOVERNOR & FILTER” as per EN676.
! Backpressure of boiler/application must be added/included in order to have the total minimum pressure drop.
MB-DLE 407 - MB-DLE 410 - MB-DLE 412 - MB-DLE 415 - MB-DLE 420
7
2. Ball valve
ACS
3. Antivibrating coupling
ACS
5. Minimum gas pressure switch 6. Safety + Working gas valve 7. Gas governor and filter included
EN676
Compact double solenoid valve with integrated filter, regulator and minimum pressure switch
8. Gas leakage control 5
3
6
8
KIT - Maximum gas pressure switch
KITPRES
ACS - Gas train connection pipe
GTCP **
1. Main gas pipe
Double solenoid valves and minimum pressure switch + ACS gas governor and filter VCS 125 R/LW Rp 1” - VCS 240 R/LW Rp 1”1/2 - VCS 350 R/LW Rp 2”
2. Ball valve
ACS
3. Antivibrating coupling
ACS
4. Gas governor & filter 5. Minimum gas pressure switch 6. Safety gas valve 7. Working gas valve
ACS
8. Gas leakage control 1
2
3
4
5
6
8
7
GAS TRAIN KITTC *
KIT - Maximum gas pressure switch
KITPRES
ACS - Gas train connection pipe
GTCP **
1. Main gas pipe
VGD SIEMENS
2. Ball valve
ACS
VGD 20.503 Rp 2” / VGD 40.065 - 40.080 - 40.100 - 40.125
3. Antivibrating coupling
ACS
5. Minimum gas pressure switch
7
6
6. Safety gas valve + 10. Actuator 7. Working gas valve + 11. Actuator 8. Gas leakage control
2
3
9
5
8
11
10
Export
Double gas valves with actuators and regulator and minimum pressure switch + ACS gas filter
1
GAS TRAIN KITTC *
9. Gas filter
ACS
KIT - Maximum gas pressure switch
KITPRES
ACS - Gas train connection pipe
GTCP **
Default blank spring: head pressure 0...22 mbar. Yellow spring: head pressure 15...120 mbar From BLU 3000.1 - MULTICALOR 300.1 - MULTIFLAM 300.1 change spring and damping
* EN676 CONFIGURATION: for VCS gas trains gas governor and filter must be included; for VGD filter must be included.
! KITTC-... Tightness control device (VPS-VDK-LDU) must be included over 1200 kW according to EN676.
** WARNING: from BLU 1700.1 - MULTICALOR 170.1 - MULTIFLAM 300.1, in order to fit the gas train, the corresponding
! connection pipe must be ordered (GTCP size and fitting depend on the burner and the gas train selected). 14
www.ecoflam-burners.com
EN676
VCS KROMSCHRÖDER
EN676
2
KITTC *
Export
1
GAS TRAIN
EN676
1. Main gas pipe
MULTIBLOC DUNGS
GAS TRAIN - KIT - ACCESSORIES ASSEMBLY TO THE BURNER
HOW TO INSTALL THE GAS TRAIN INTO THE BURNER AND CALCULATE THE OVERALL DIMENSIONS MAX GAS 40 ÷ 250 Gas train with connection on the top
BLU 1700.1 ÷ 18000.1 MULTICALOR 170.1 ÷ 1800.1 MULTIFLAM 300.1 ÷ 1800.1 Gas train with connection at the bottom, right hand side layout (or left with kit)
MAX GAS 350 ÷ 500 BLU 700.1 ÷ 1500.1 MULTICALOR 45 ÷ 140 Gas train with right hand side connection
DUOBLOCK Gas train with connection at the bottom, right hand side layout (or left with kit)
* WARNING: from BLU 1700.1 - MULTICALOR 170.1 - MULTIFLAM 300.1:
! in order to fit the gas train the corresponding connection pipe must be ordered
KIT AND ACCESSORIES GAS GOVERNOR/FILTER
MAX GAS PRESSURE SWITCH
FGDR - FILTER
KITPRES50 KITPRES150
Compulsory EN676
TIGHTNESS CONTROL KITTC- Model
Compulsory over 1200 kW
MODULATION KIT
LPG TRANSFORMATION
KITMD-RWF50 PROBE-...
KITLPG-MAXGAS... KITLPG-BLU...
WARNING: EN676 compulsory kit and accessories must be ordered to comply with the safety regulations. Additional
! accessories and kits shall be installed by the installer in accordance with the local safety regulations and codes of practise. www.ecoflam-burners.com
15
ELECTRONIC VERSION WITH BURNER MANAGEMENT SYSTEM ECOFLAM offers the electronic range with BMS from 2 MW up to 17 MW in Monoblock and up to 25 MW in Duoblock configuration with electrical panel assembled into the burner or on request with separate switch cabinet.
T P
Pmax OIL
Pmin OIL
M
PAIR
For all burners the delivery scope is in a modular system, i.e.:
CAN-Bus
• BBCH: burner body with combustion head; • GT: gas train; • KIT-ACS: kits and accessories to complete the burner in order to comply with the local safety regulations and codes of practise; • Heavy oil and dual fuel (gas/heavy oil) are delivered with pre-heater assembled into the burner body or on request in a separate frame/skid; • SV: separate ventilator for Duoblock version.
BUS multi
Pmin GAS
PLT GAS
TS RANGE - DUOBLOCK BURNERS
SELECTED OUTPUT TO MATCH MAIN BOILERS AND INDUSTRIAL APPLICATION Available models for different fuels in standard progressive mechanical configuration with derivative electrical panel. Electronic version with Burner Management System with separate switch cabinet on request.
Platform Max output range 260 0,8 ÷ 1,5 MW 280
16
1,5 ÷ 2 MW
Light oil MAIOR 120
Heavy oil OILFLAM 120.1
Gas BLU 1500.1
Gas/Light oil MULTICALOR 140
Gas/Heavy oil -
MAIOR 200.1
OILFLAM 200.1
BLU 2000.1
MULTICALOR 200.1
MULTIFLAM 200.1
320
3 ÷ 4 MW
MAIOR 400.1
OILFLAM 400.1
BLU 4000.1
MULTICALOR 400.1
MULTIFLAM 400.1
380
5 ÷ 6 MW
MAIOR 600.1
OILFLAM 600.1
BLU 6000.1
MULTICALOR 600.1
MULTIFLAM 600.1
630
7 ÷ 9 MW
MAIOR 800.1
OILFLAM 800.1
BLU 8000.1
MULTICALOR 800.1
MULTIFLAM 800.1
630
10 ÷ 13 MW
MAIOR 1200.1
OILFLAM 1200.1
BLU 12000.1
MULTICALOR 1200.1
MULTIFLAM 1200.1
710
15 ÷ 18 MW
MAIOR 1800.1
OILFLAM 1800.1
BLU 18000.1
MULTICALOR 1800.1
MULTIFLAM 1800.1
800
22 ÷ 25 MW
www.ecoflam-burners.com
Feasibility only on request
MONOBLOCK - DUOBLOCK RANGE WITH BMS Electronic compound manager for burner has been introduced into ECOFLAM range in order to improve performance and efficiency of modern firing installation. BMS is a compact powerful solution suitable for the control and supervision of single or dual fuel forced draft burners. This system is designed to match an extensive range of components such as flame, temperature and pressure sensors, gas valves, variable speed fan motors and oxygen control that can be managed from different bus interfaces. BMS solutions are meant to bring the main following benefits: • • • • • • •
significant energy saving in both fuel and electricity; optimize process performance and minimize costs; simple commissioning and operating in total safety; integrated solution with a wide range of communication interfaces; combustion optimization with O2/CO control; effective diagnostic and real time status information; user interface easy to use and program.
Communication interface Temperature Pressure sensors
Flame sensors
Leakage System
Display
Actuators
INVERTER SYSTEM
VSD module is an extension to the BMS and is used for the control of a variable speed drive, that allows electrical comsumption savings, lower noise emissions, gradual fan starting and reduction of mechanical stress.
O2 Trim
O2-CO TRIM CONTROL
O2-CO control allows the control of the residual oxygen content in order to increase the boiler efficiency.
CO Trim
VSD Inverter
MONITORING APPLICATION
Reliable and safe flame detection system for single and multiple burner furnaces.
RANGE OF OUTPUT WITH BURNER MANAGEMENT SYSTEM Turndown ratio standard
with inverter
oil side
VSD inverter
MAIOR 200.1-1800.1
1÷5
1÷5
1÷5
Kit
Kit
OILFLAM 200.1-1800.1
1÷5
1÷5
1÷5
Kit
Kit
BLU 2000.1-18000.1
1÷6
1÷8
1÷5
Kit
Kit
MULTICALOR 200.1-1800.1
1÷6
1÷8
1÷5
Kit
Kit
MULTIFLAM 200.1-1800.1
1÷6
1÷8
1÷5
Kit
Kit
DUOBLOCK
1÷6
1÷8
1÷5
Kit
Kit
Model
O2-CO trim
Additional functions Flame monitoring sensors Communication interfaces Display interface
www.ecoflam-burners.com
17
18
www.ecoflam-burners.com
All light oil burners are delivered complete in one single package including filter and flexible hoses up to 6 MW.
DUOBLOCK and ELECTRONIC versions are available on request for selected output to match main boilers and industry application.
MAIOR models over 7 MW are available on request based on the configuration requested (mechanical or electronic) in order to better fit into the application and provide a customised and more cost effective solution.
MAIOR range for light oil are available in two stages with hydraulic system or servomotor up to 350 kg/h and from the model MAIOR 45 in progressive operation that can be turned in modulating with a PID regulator.
MAIOR - Max visc. 1,5°E at 20°C
The range is available in standard class 2 and Low NOx emission class 3 (yellow flame) according to EN267. The range fits standard heating and light industry applications.
MAX range for light oil combines a high efficiency fan ventilation system (HPV) with features ranging from easy matching on boilers up to easy maintenance and set-up.
MAX - Max visc. 1,5°E at 20°C
LIGHT OIL BURNERS
instruction manual for adjustments and modifications.
All burners 230-400V/50Hz are factory tested at 400V/50Hz
! three-phase. If main supply is three-phase 230V/50Hz see
• CV: Continuous ventilation version • HT: High temperature version • D pump: light oil with max viscosity 5°E at 20°C • OEM and special application version only on request
AVAILABLE CONFIGURATIONS ON REQUEST
• KIT Biodiesel • KIT Wieland plugs • Light oil pump unit on request • PID modulating KIT and probe • Diagnostic tool for TW control box • Silencer (starting from platform 260)
KIT - ACS (see dedicated pages)
www.ecoflam-burners.com
19
47 60 73,4 86,4 110
MAX 8 TW - 1/230V/50-60Hz
MAX 12 TW - 1/230V/50-60Hz
MAX 15 TW - 1/230V/50Hz
MAX 20 TW - 1/230V/50Hz
MAX 30 TW - 1/230V/50Hz
166 202
MAX P 35 AB TW - 1/230V/50Hz
MAX P 45 AB TW - 3/230-400V/50Hz
MODEL MIN
20
MAX 4 R TW - 1/230V/50-60Hz
Two stages class 2 (NOx <185 mg/kWh) - B10
20
MAX 1 R TW - 1/230V/50-60Hz
MODEL MIN
20
MAX 4 TW - 1/230V/50-60Hz
One stage with pre-heater versions (NOx <185 mg/kWh) - B10
17,6
MIN
17,6 22,5
MIN
MAX 1 TW - 1/230V/50-60Hz
MODEL
One stage class 2 (NOx <185 mg/kWh) - B10
MAX 1 Low NOx TW - 1/230V/50-60Hz MAX 4 Low NOx TW - 1/230V/50-60Hz
MODEL
One stage Low NOx class 3 (NOx <120 mg/kWh) - B10
LIGHT OIL BURNERS MAX
OUTPUT [kW]
OUTPUT [kW]
OUTPUT [kW]
OUTPUT [kW]
546
427
MAX
59
39
MAX
319
237
190
130
105
59
41,4
MAX
35,5 47,4
MAX
17
14
MIN
1,7
1,5
MIN
9,3
7,3
6,2
5,1
4
1,7
1,5
MIN
1,5 1,9
MIN
FLOW RATE [kg/h]
FLOW RATE [kg/h]
FLOW RATE [kg/h]
FLOW RATE [kg/h]
46
36
MAX
5
3,5
MAX
27
20
16
11
8,9
5
3,5
MAX
3 4
MAX
CODE
3140420 3140421 3140933 3141314
TC TL TC TL
3142711 3142712 3142720 3142721
TC TL TC TL
BLAST TUBE
CODE
3142709 3142710 3142714 3142715 3142716 3142717 3142718 3142719 3142729 3142730 3142731 3142732 3142733 3142734
TC TL TC TL TC TL TC TL TC TL TC TL TC TL
BLAST TUBE
CODE
3142713 3142722
CODE
BLAST TUBE
TC TC
BLAST TUBE
20
www.ecoflam-burners.com
102 166 202
MAX P 25 AB HS - 1/230V/50Hz
MAX P 35 AB HS TW - 1/230V/50Hz
MAX P 45 AB HS TW - 3/230-400V/50Hz
47 60 73,4 86,4 110 166 202
MAX 8 HT TW - 1/230V/50-60Hz
MAX 12 HT TW - 1/230V/50-60Hz
MAX 15 HT TW - 1/230V/50Hz
MAX 20 D HT TW - 1/230V/50Hz
MAX 30 D HT TW - 1/230V/50Hz
MAX P 35 AB HS D HT TW - 1/230V/50Hz
MAX P 45 AB HS D HT TW - 3/230-400V/50Hz
OUTPUT [kW]
OUTPUT [kW]
DESCRIPTION
Diagnostic tool for TW control box
KIT - ACCESSORIES see accessories page
B10: oil pump for biodiesel; D pump: max viscosity 5째E at 20째C; HT: high temperature
20
MAX 4 HT TW - 1/230V/50-60Hz
MODEL MIN
77
MAX P 15 AB HS - 1/230V/50Hz
One stage class 2 (NOx <185 mg/kWh) - B10
60
MIN
MAX P 12 AB HS - 1/230V/50-60Hz
MODEL
Two stages hydraulic system class 2 (NOx <185 mg/kWh)
LIGHT OIL BURNERS MAX
546
427
319
237
190
130
105
59
MAX
546
427
300
190
130
MAX
17
14
9,3
7,3
6,2
5,1
4
1,7
MIN
17
14
8,6
6,5
5,1
MIN
FLOW RATE [kg/h]
FLOW RATE [kg/h]
46
36
27
20
16
11
8,9
5
MAX
46
36
25,4
16
11
MAX
CODE
3142724 3142723 3142726 3142725 3142728 3142727 3142735 3142736 3142737 3142738 3142739 3142740 on request on request on request on request
TC TL TC TL TC TL TC TL TC TL TC TL TC TL TC TL
3124094 3124095 3122708 3122709 3122710 3122274 3140409 3140412 3140418 3140419
TC TL TC TL TC TL TC TL TC TL
BLAST TUBE
CODE
BLAST TUBE
www.ecoflam-burners.com
21
830 592 710 1000 1300
MAIOR P 120 AB HS - 3/230-400V/50Hz
MAIOR P 150.1 AB HS - 3/230-400V/50Hz
MAIOR P 200.1 AB HS - 3/230-400V/50Hz
MAIOR P 300.1 AB HS - 3/400V/50Hz
MAIOR P 400.1 AB HS Z3 - 3/400V/50Hz
710 1000 1300
MAIOR P 200.1 AB - 3/230-400V/50Hz
MAIOR P 300.1 AB - 3/400V/50Hz
MAIOR P 400.1 AB Z3 - 3/400V/50Hz
830
MAIOR P 120 AB - 3/230-400V/50Hz 592
474
MAIOR P 80 AB - 3/230-400V/50Hz
MAIOR P 150.1 AB - 3/230-400V/50Hz
415
MAIOR P 60 AB - 3/230-400V/50Hz
MIN
474
MAIOR P 80 AB HS - 3/230-400V/50Hz
MODEL
415
MAIOR P 60 AB HS D - 3/230-400V/50Hz
Two stages
415
MIN
MAIOR P 60 AB HS - 3/230-400V/50Hz
MODEL
Two stages hydraulic system
LIGHT OIL BURNERS MAIOR
OUTPUT [kW]
OUTPUT [kW]
3900
3000
2372
1780
1423
949
710
MAX
3900
3000
2372
1780
1423
949
710
710
MAX
110
85
60
50
70
40
35
MIN
110
85
60
50
70
40
35
35
MIN
FLOW RATE [kg/h]
FLOW RATE [kg/h]
350
250
200
150
120
80
60
MAX
350
250
200
150
120
80
60
60
MAX
OPT
OPT
OPT
OPT
OPT
OPT
OPT
SILENCER
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
SILENCER
CODE
3121016 3122265 3121018 3122266 3121020 3122269 3121022 3121021 3121024 3121023 3143731 3143742 3143733 3143732
TC TL TC TL TC TL TC TL TC TL TC TL TC TL
3140151 3140152 3141572 3141571 3121063 3121064 3121065 3121066 3121067 3121068 3121069 3121070 3143743 3143744 3143745 3143746
TC TL TC TL TC TL TC TL TC TL TC TL TC TL TC TL
BLAST TUBE
CODE
BLAST TUBE
22
www.ecoflam-burners.com
1300 1578 1795 2417 2750 3300 4367 5000 5700
MAIOR P 400.1 PR - 3/400V/50Hz
MAIOR P 500.1 PR - 3/400V/50Hz
MAIOR P 600.1 PR - 3/400V/50Hz
MAIOR P 700.1 PR - 3/400V/50Hz MAIOR P 800.1 PR - 3/400V/50Hz MAIOR P 1000.1 PR - 3/400V/50Hz MAIOR P 1200.1 PR - 3/400V/50Hz MAIOR P 1500.1 PR - 3/400V/50Hz MAIOR P 1800.1 PR - 3/400V/50Hz
see accessories page see accessories page see accessories page see accessories page see accessories page
1000
MAIOR P 300.1 PR - 3/400V/50Hz
OUTPUT [kW]
7500 8500 10500 12500 15000 17000
5800
5000
3900
3000
532 710 949 1423 1780 2372
MAX
205 234 281 371 422 481
153
134
110
85
25 35 40 70 50 60
MIN
FLOW RATE [kg/h]
MAIOR - DUOBLOCK AND ELECTRONIC BURNERS Versions from 2 to 25 MW are available on request for selected output to match main boilers and industry application.
Silencer Modulation kit Probe Pumping unit Kit Wieland plugs
DESCRIPTION
KIT - ACCESSORIES
296 415 474 830 592 710
MIN
MAIOR P 45 PR - 3/230-400V/50Hz MAIOR P 60 PR - 3/230-400V/50Hz MAIOR P 80 PR - 3/230-400V/50Hz MAIOR P 120 PR - 3/230-400V/50Hz MAIOR P 150.1 PR - 3/230-400V/50Hz MAIOR P 200.1 PR - 3/230-400V/50Hz
MODEL
Two stage progressive mechanical
LIGHT OIL BURNERS MAIOR
634 718 887 1053 1265 1433
490
422
350
250
45 60 80 120 150 200
MAX
OPT OPT OPT OPT OPT OPT
OPT
OPT
OPT
OPT
OPT OPT OPT OPT OPT OPT
SILENCER
TL TL TL TL TL TL TC TL TC TL TC TL TC TL TC TC TC TC TC TC
BLAST TUBE
on request on request on request on request on request on request 3143734 3143735 3143736 3143737 3143738 3143739 3143740 3143741 on request on request on request on request on request on request
CODE
www.ecoflam-burners.com
23
All heavy oil burners are delivered with electrical pre-heater preassembled into the burner body, including filter and flexible hoses up to 6 MW.
DUOBLOCK and ELECTRONIC versions are available on request for selected output to match main boilers and industry application.
OILFLAM models over 7 MW are offered on request based on the configuration requested (mechanical or electronic) in order to better fit into the application and provide a customised and more cost effective solution.
Easy maintenance system is integrated into the burner: • HINGE FLANGE SYSTEM for OILFLAM 80.1 to 200.1 and 1500.1 to 1800.1 • SLIDING BAR SYSTEM for MAXFLAM 10 to 50 and OILFLAM 300.1 to 1200.1
OILFLAM models from 300.1 are supplied with “GEFRAN” digital thermo regulator integrated on the front panel for granting temperature stability of fuel. Available version includes double stage up to 350 kg/h and from the model OILFLAM 300.1 in progressive operation that can be turned in modulating with a PID regulator.
OILFLAM - Max visc. 50°E at 50°C
M100 configuration for heavy oil up to 100°E at 50°C is available on request.
MAXFLAM and OILFLAM range work with heavy oil up to 50°E at 50°C with On/Off switch to exclude the circuit heaters in order to operate also with low viscosity heavy oil.
MAXFLAM - Max visc. 50°E at 50°C
HEAVY OIL BURNERS
instruction manual for adjustments and modifications.
All burners 230-400V/50Hz are factory tested at 400V/50Hz
! three-phase. If main supply is three-phase 230V/50Hz see
• M100 version for heavy oil up to 100°E at 50°C • From OILFLAM 300.1 pre-heater can be supplied separately with extra cost • Forced oil preparation ring system on request
AVAILABLE CONFIGURATIONS ON REQUEST
• KIT Wieland plugs • KIT magnetic + selfcleaning filter • PID modulating KIT and probe • Silencer (starting from platform 260)
KIT - ACS (see dedicated pages)
24
www.ecoflam-burners.com
170
MAXFLAM 30 - 3/230-400V/50Hz
464 682 682 682 1000 1300
OILFLAM 80.1 AB - 3/230-400V/50Hz
OILFLAM 120.1 AB - 3/230-400V/50Hz
OILFLAM 170.1 AB - 3/230-400V/50Hz
OILFLAM 200.1 AB - 3/230-400V/50Hz
OILFLAM 300.1 AB - 3/400V/50Hz
OILFLAM 400.1 AB Z3 - 3/400V/50Hz
MODEL
Two stages - 50°E fuel viscosity at 50°C MIN
205
MAXFLAM 50 AB - 3/230-400V/50Hz
OILFLAM
205
MAXFLAM 30 AB - 3/230-400V/50Hz
MODEL MIN
108
MAXFLAM 20 - 1/230V/50Hz
Two stages - 50°E fuel viscosity at 50°C
68
MIN
MAXFLAM 10 - 1/230V/50Hz
MODEL
One stage - 50°E fuel viscosity at 50°C
HEAVY OIL BURNERS MAXFLAM
OUTPUT [kW]
3900
3000
2093
1700
1395
930
MAX
OUTPUT [kW]
OUTPUT [kW]
570
410
MAX
340
227
136
MAX
115
88,5
60
60
60
41
MIN
343
264
184
148
122
82
MAX
FLOW RATE [kg/h]
FLOW RATE [kg/h]
FLOW RATE [kg/h]
18
18
MIN
15
9,5
6
MIN
50
36
MAX
30
20
12
MAX
OPT
OPT
OPT
OPT
OPT
OPT
SILENCER
CODE
3142604 3142605 3142606 3142607 3142608 3142609 3142610 3142611 3143753 3143754 3143755 3143756
TC TL TC TL TC TL TC TL TC TL TC TL
3143330 3143331 3143332 3143333
TC TL TC TL
BLAST TUBE
CODE
3143324 3143325 3143326 3143327 3143328 3143329
TC TL TC TL TC TL
BLAST TUBE
CODE
BLAST TUBE
www.ecoflam-burners.com
25
1000 1300 1578 1795 2417 2750 3300 4367 5000 5700
OILFLAM 300.1 PR - 3/400V/50Hz
OILFLAM 400.1 PR - 3/400V/50Hz
OILFLAM 500.1 PR - 3/400V/50Hz
OILFLAM 600.1 PR - 3/400V/50Hz
OILFLAM 700.1 PR - 3/400V/50Hz OILFLAM 800.1 PR - 3/400V/50Hz OILFLAM 1000.1 PR - 3/400V/50Hz OILFLAM 1200.1 PR - 3/400V/50Hz OILFLAM 1500.1 PR - 3/400V/50Hz OILFLAM 1800.1 PR - 3/400V/50Hz
DESCRIPTION
7500 8500 10500 12500 15000 17000
5800
5000
3900
3000
1395 1700 2093
930
MAX
214 243 292 386 440 501
159
140
115
88,5
60 60 60
41
MIN
FLOW RATE [kg/h]
OILFLAM - DUOBLOCK AND ELECTRONIC BURNERS Versions from 2 to 25 MW are available on request for selected output to match main boilers and industry application.
Silencer Modulation kit Probe Heating and pumping unit Magnetic + self cleaning filter
OUTPUT [kW]
see accessories page see accessories page see accessories page see accessories page see accessories page
682 682 682
KIT - ACCESSORIES
464
OILFLAM 120.1 PR - 3/230-400V/50Hz OILFLAM 170.1 PR - 3/230-400V/50Hz OILFLAM 200.1 PR - 3/230-400V/50Hz
MIN
OILFLAM 80.1 PR - 3/230-400V/50Hz
MODEL
Two stage progressive mechanical - 50째E fuel viscosity at 50째C
HEAVY OIL BURNERS OILFLAM
660 748 924 1097 1319 1495
510
440
343
264
122 148 184
82
MAX
OPT OPT OPT OPT OPT OPT
OPT
OPT
OPT
OPT
OPT OPT OPT
OPT
SILENCER
on request on request on request 3143757 3143758 3143759 3143760 3143761 3143762 3143763 3143764 on request on request on request on request on request on request
TC TL TC TL TC TL TC TC TC TC TC TC
on request
CODE
TL TL TL TC TL
TL
BLAST TUBE
26
www.ecoflam-burners.com
The filtering system operation: the first magnetic filter allows to separate all ferrous impurities contained in the oil and the second lamellar filter allows the final filtration of all impurities.
MAGNETIC + SELF CLEANING FILTER
Service tanks + Pumps units. Quotation on request depending on output and configuration.
ACCESSORIES
ECOFLAM heavy oil burners are delivered with electrical pre-heater assembled into the burner body or in a separate skid. Additional Forced system â&#x20AC;&#x153;OIL RINGâ&#x20AC;? can be design and delivered assembled on skid/frame or offered as single component.
PRE-HEATER UNIT
1. Feeding and filtering system 2. Fuel heating system for reducing oil viscosity plus service tank 3. Forced oil supply system â&#x20AC;&#x153;RINGâ&#x20AC;?
STANDARD SYSTEM COMPOSITION FOR LIGHT OIL AND HEAVY OIL HEATING AND PUMPING UNIT
FORCED OIL PREPARATION RING
A 3
5
13
12
3 6
hot water pipe / steam pipe
insula on
Return
7
electrical hea ng cable
hot water pipe / steam pipe
sez. A-A : sec on B-B
5
oil pipe
T
oil pipe
T
4
9
B
For heavy oil with more than 50°E at 50°C ECOFLAM recommends to decrease the maximum output of 10-20% and work in eccess of air in order to grant better operation and reduce maintenance.
All installations using heavy oil burners have to be completed with a Forced oil preparation ring in order to guarantee oil supply to the burner at suitable temperature and pressure (temperature +/- 80°C, pressure 3 bar).
OIL ! HEAVY WARNINGS
7
8
11
A
2
HEAVY OIL PREPARATION RING: SUGGESTED SCHEME
B
10
1. Burners 2. Service tank 3. Electric heaters 4. Safety and operation thermostat 5. Level switch (working + safety) 6. Heating coil 7. Self cleaning oil filter 8. Load pumps 9. Ring pumps 10. Oil ring control pressure device 11. Heating cable 12. Main heavy oil storage tank 13. Heating coil
LEGENDA
1
1
www.ecoflam-burners.com
27
Gas train matching table and pressure drop diagrams for natural gas/LPG are available in the gas train technical documentation.
EXPORT configuration (other additional options to be added by installer in compliance with local safety regulations): • double solenoid valves VCS Kromschröder: double solenoid valves including min gas pressure switch; • GasMultiBloc Dungs GB-LE 055 Class B: compact double solenoid valve with integrated filter, regulator and min pressure switch available for MAX GAS 40-120; • single solenoid valve Brahma E6G*SR P and EG12*L for MAX GAS 40-120 complete with min gas pressure switch; • single solenoid valve Kromschröder VAS125 and VAS240 for MAX GAS 170-250 complete with min gas pressure switch.
EN676 configuration: • GasMultiBloc Dungs: compact double solenoid valve with integrated filter, regulator and min pressure switch; • double solenoid valves VCS Kromschröder: double solenoid valves including min gas pressure switch + separate gas governor and filter FGDR.
All MAX GAS are delivered for natural gas and can operate with LPG by changing the nozzle with a kit. MAX GAS two stages are complete with two stages MultiBloc valves MBZRDLE for the models 120-250 where models 350-500 operate in two stage with butterfly valve. Progressive version are availble for models MAX GAS 350-500 and can be transformed into modulating with the PID KITMD-RWF50.
BBCH: Burner Body with Combustion Head → TC short head and TL long head GT: Gas train separate → EN676 or Export configuration KIT & ACS: kits and accessories according to local rules installation
MAX GAS range is available in the following versions and is delivered in a modular system of boxes: • P: 1 stage soft start • PAB: 2 stages • PR: 2 stage progressive mechanical
MAX GAS - Low NOx class 3 (<80 mg/kWh)
GAS BURNERS
instruction manual for adjustments and modifications.
All burners 230-400V/50Hz are factory tested at 400V/50Hz
! three-phase. If main supply is three-phase 230V/50Hz see
• CV: Continuous ventilation version • HT: High Temperature version • OEM and special application version only on request
AVAILABLE CONFIGURATIONS ON REQUEST
• LPG KIT • KIT Wieland plugs • PID modulating KIT and probe • Antivibration coupling and ball valve
KIT - ACS (see dedicated pages)
28
www.ecoflam-burners.com
GT-D1-GBLE055-RP15-MAXGAS40-120 GT-H1-E6GSRP-RP15-MAXGAS40-120 GT-H1-EG12L-RP15-MAXGAS40-120 GT-K1-VAS125-RP25-MAXGAS170-250 GT-K1-VAS240-RP40-MAXGAS170-250
DESIGNATION
GAS TRAIN - Export configuration
1/230V/50-60Hz
MAX GAS 120 P TW
1/230V/50-60Hz
MAX GAS 105 P TW
1/230V/50-60Hz
MAX GAS 70 P TW
1/230V/50-60Hz
MAX GAS 40 P TW
MODEL
49
49
34
17
MIN
120
108
70
48
MAX
DESCRIPTION
3142748
3142747
TC
TL
3142746
3142745
TC
TL
3142744
3142743
TC
TL
3142742
3142741
TL
TC
BURNER BODY BLAST TUBE CODE
MultiBloc class B - EN676 up to 70 kW single solenoid valve with min gas pressure switch single solenoid valve with min gas pressure switch single solenoid valve with min gas pressure switch single solenoid valve with min gas pressure switch
OUTPUT [kW]
One stage Low NOx class 3 (NOx <80 mg/kWh)
GAS BURNERS MAX GAS
40-120 40-120 40-120 170-250 170-250
TYPE OF BURNER
9 9 9 9 10 11 16 18 10 11 16 18 16 18 34 36 16 18 34 36 16 18 34 36 16 18 34 36
65 200 65 200 360 360 65 200 360 360 65 200 360 360 65 200 360 360 65 200 360 360 65 200 360 360 65 200
PRESSURE [mbar] MIN MAX
Ø
1/2" 1/2" 1/2" 1" 1"1/2
3141885 3123944 3141885 3123944 3123560 3141886 3141885 3123944 3123560 3141886 3141885 3123944 3123560 3141886 3141885 3123944 3123560 3141886 3141885 3123944 3123560 3141886 3141885 3123944 3123560 3141886 3141885 3123944
CODE
MBC 65 DLE MB-DLE 403 MBC 65 DLE MB-DLE 403 MB-DLE 405 MBC 120 DLE MBC 65 DLE MB-DLE 403 MB-DLE 405 MBC 120 DLE MBC 65 DLE MB-DLE 403 MB-DLE 405 MBC 120 DLE MBC 65 DLE MB-DLE 403 MB-DLE 405 MBC 120 DLE MBC 65 DLE MB-DLE 403 MB-DLE 405 MBC 120 DLE MBC 65 DLE MB-DLE 403 MB-DLE 405 MBC 120 DLE MBC 65 DLE MB-DLE 403
GAS TRAIN TYPE
1/2"
3/4"
1/2"
3/4"
1/2"
3/4"
1/2"
3/4"
1/2"
3/4"
1/2"
3/4"
1/2"
1/2"
Ø
CODE
3142027 3141888 3141887 3142815 3142816
included
included
included
included
included
included
included
included
GAS GOVERNOR AND FILTER
www.ecoflam-burners.com
29
120
100
55
55
500
350
240
175
OUTPUT [kW] MIN MAX
3143286
3143285
TC
TL
3143284
3143283
TC
TL
3142752
3142751
TC
TL
3142750
3142749
TL
TC
BURNER BODY BLAST TUBE CODE
3/230-400V/50Hz
MAX GAS 500 P TW
1/230V/50Hz
MAX GAS 350 P TW
1/230V/50Hz
MAX GAS 250 P TW
1/230V/50Hz
MAX GAS 170 P TW
MODEL
120
100
55
55
500
350
240
175
OUTPUT [kW] MIN MAX
3143286
3143285
TC TL
3143284
3143283
TC TL
3142752
3142751
TC TL
3142749 3142750
TC TL
BURNER BODY BLAST TUBE CODE
One stage Low NOx class 3 (NOx <80 mg/kWh) - VCS gas train versions - 1/230/50-60Hz
3/230-400V/50Hz
MAX GAS 500 P TW
1/230V/50Hz
MAX GAS 350 P TW
1/230V/50Hz
MAX GAS 250 P TW
1/230V/50Hz
MAX GAS 170 P TW
MODEL
20 20 15 34 15 34 18 54 18 54 24 98 24 98
500
500
500
500
500
500
500 500
360
360
360
360
360
360
360
360
PRESSURE [mbar] MIN MAX
13 17 26 13 17 26 15 17 26 40 15 17 26 40 17 20 37 60 17 20 37 60 20 35 55 90 20 35 55 90
PRESSURE [MBAR] MIN MAX
3141906 3141906 3142251 3141906 3142251 3141906 3142375 3142374 3142375 3142374 3142375 3142374 3142375 3142374
CODE
3123947 3123525 3123560 3123947 3123525 3123560 3141899 3123947 3123525 3123560 3141899 3123947 3123525 3123560 3142296 3142295 3142665 3142392 3142296 3142295 3142665 3142392 3142296 3142295 3142665 3142392 3142296 3142295 3142665 3142392
CODE
VCS-125 VCS-125 VCS-240 VCS-125 VCS-240 VCS-125 VCS-240 350/500 VCS-125 350/500 VCS-240 350/500 VCS-125 350/500 VCS-240 350/500 VCS-125 350/500 VCS-240 350/500 VCS-125 350/500
GAS TRAIN TYPE
MB-DLE 410 MB-DLE 407 MB-DLE 405 MB-DLE 410 MB-DLE 407 MB-DLE 405 MB-DLE 412 MB-DLE 410 MB-DLE 407 MB-DLE 405 MB-DLE 412 MB-DLE 410 MB-DLE 407 MB-DLE 405 MB-DLE 415 350/500 MB-DLE 412 350/500 MB-DLE 410 350/500 MB-DLE 407 350/500 MB-DLE 415 350/500 MB-DLE 412 350/500 MB-DLE 410 350/500 MB-DLE 407 350/500 MB-DLE 415 350/500 MB-DLE 412 350/500 MB-DLE 410 350/500 MB-DLE 407 350/500 MB-DLE 415 350/500 MB-DLE 412 350/500 MB-DLE 410 350/500 MB-DLE 407 350/500
GAS TRAIN TYPE
1" 1" 1"1/2 1" 1"1/2 1" 1"1/2 1" 1"1/2 1" 1"1/2 1" 1"1/2 1"
Ø
1" 3/4" 3/4" 1" 3/4" 3/4" 1"1/4 1" 3/4" 3/4" 1"1/4 1" 3/4" 3/4" 1"1/2 1"1/4 1" 3/4" 1"1/2 1"1/4 1" 3/4" 1"1/2 1"1/4 1" 3/4" 1"1/2 1"1/4 1" 3/4"
Ø
3142521 3142521 3142523 3142521 3142523 3142521 3142523 3142521 3142523 3142521 3142523 3142521 3142523 3142521
FGDR 1" FGDR 1" FGDR 1"1/2 FGDR 1" FGDR 1"1/2 FGDR 1" FGDR 1"1/2 FGDR 1" FGDR 1"1/2 FGDR 1" FGDR 1"1/2 FGDR 1" FGDR 1"1/2 FGDR 1"
GAS GOVERNOR AND FILTER CODE TYPE
included
included
included
included
3122300
included
3122300
included
3122300
included
3122300
included
GAS GOVERNOR + FILTER KIT ADAPTOR
30
www.ecoflam-burners.com
3/230-400V/50Hz
MAX GAS 500 PAB TW
1/230V/50Hz
MAX GAS 350 PAB TW
1/230V/50Hz
MAX GAS 250 PAB TW
1/230V/50Hz
MAX GAS 170 PAB TW
1/230V/50-60Hz
MAX GAS 120 PAB
MODEL
120
100
55
55
40
MIN
500
350
240
175
120
MAX
OUTPUT [kW]
Two stages Low NOx class 3 (NOx <80 mg/kWh)
3143290
3143289
TC
TL
3143288
3143287
TC
TL
3142785
3142784
TC
TL
3142783
3142782
TC
TL
3123955
TC TL
CODE
3123954
BLAST TUBE
BURNER BODY
90
55
3142392
3142665
3142295 360
35
3142392 3142296
20
90
3142665
35
360
3142296 3142295
20 55
3142392
60
3142665
3142295
360
20 37
3142296
3142392
17
60
3142665
3142295
20 37
3142296 360
3123960
17
3123961
40
26
3123962
17 360
3141901
3123960
3123961
15
40
26
3141901 3123962
15 17 360
3123962 3123961 3123960
360
3123960
26
17
13
26
3123962
3123960 3123961
360
CODE
3123960
13
360
360
MAX
17
16
16
MIN
PRESSURE [mbar]
MB-DLE 407 350/500
MB-DLE 410 350/500
MB-DLE 412 350/500
MB-DLE 415 350/500
MB-DLE 407 350/500
MB-DLE 410 350/500
MB-DLE 412 350/500
MB-DLE 415 350/500
MB-DLE 407 350/500
MB-DLE 410 350/500
MB-DLE 412 350/500
MB-DLE 415 350/500
MB-DLE 407 350/500
MB-DLE 410 350/500
MB-DLE 412 350/500
MB-DLE 415 350/500
MB-ZRDLE 405
MB-ZRDLE 407
MB-ZRDLE 410
MB-ZRDLE 412
MB-ZRDLE 405
MB-ZRDLE 407
MB-ZRDLE 410
MB-ZRDLE 412
MB-ZRDLE 405
MB-ZRDLE 407
MB-ZRDLE 410
MB-ZRDLE 405
MB-ZRDLE 407
MB-ZRDLE 410
MB-ZRDLE 405
MB-ZRDLE 405
TYPE
GAS TRAIN Ø
3/4"
1"
1"1/4
1"1/2
3/4"
1"
1"1/4
1"1/2
3/4"
1"
1"1/4
1"1/2
3/4"
1"
1"1/4
1"1/2
3/4"
3/4"
1"
1"1/4
3/4"
3/4"
1"
1"1/4
3/4"
3/4"
1"
3/4"
3/4"
1"
3/4"
3/4"
included
included
included
included
3122300
included
3122300
included
3122300
included
3122300
included
included
included
GAS GOVERNOR AND FILTER KIT ADAPTOR
www.ecoflam-burners.com
31
120
100
500
350
OUTPUT [kW] MIN MAX
3143290
3143289
TC
TL
3143288
3143287
TL
TC
BURNER BODY BLAST TUBE CODE
Tightness control Modulation kit Probe LPG kit Adaptor kit for gas train Additional gas accessories
DESCRIPTION
KIT - ACCESSORIES
3/230-400V/50Hz
MAX GAS 500 PR TW
1/230V/50Hz
MAX GAS 350 PR TW
MODEL
120
100
3140050
3140049
TC
TL
3140048
3140047
TL
TC
BURNER BODY BLAST TUBE CODE
see accessories page see accessories page see accessories page see accessories page see accessories page see accessories page
500
350
OUTPUT [kW] MIN MAX
Two stage progressive mechanical Low NOx class 3 (NOx <80 mg/kWh)
3/230-400V/50Hz
MAX GAS 500 PAB TW
1/230V/50Hz
MAX GAS 350 PAB TW
MODEL
Two stages Low NOx class 3 (NOx <80 mg/kWh) - VCS gas train versions
500
500
500
500
17 20 37 60 17 20 37 60 20 35 55 90 20 35 55 90 360
360
360
360
PRESSURE [mbar] MIN MAX
18 54 18 54 14 18 54 14 18 54
PRESSURE [mbar] MIN MAX
3142296 3142295 3142665 3142392 3142296 3142295 3142665 3142392 3142296 3142295 3142665 3142392 3142296 3142295 3142665 3142392
CODE
3142375 3142374 3142375 3142374 3142376 3142375 3142374 3142376 3142375 3142374
CODE
MB-DLE 415 350/500 MB-DLE 412 350/500 MB-DLE 410 350/500 MB-DLE 407 350/500 MB-DLE 415 350/500 MB-DLE 412 350/500 MB-DLE 410 350/500 MB-DLE 407 350/500 MB-DLE 415 350/500 MB-DLE 412 350/500 MB-DLE 410 350/500 MB-DLE 407 350/500 MB-DLE 415 350/500 MB-DLE 412 350/500 MB-DLE 410 350/500 MB-DLE 407 350/500
GAS TRAIN TYPE
VCS-240 350/500 VCS-125 350/500 VCS-240 350/500 VCS-125 350/500 VCS-350 350/500 VCS-240 350/500 VCS-125 350/500 VCS-350 350/500 VCS-240 350/500 VCS-125 350/500
GAS TRAIN TYPE
1"1/2 1"1/4 1" 3/4" 1"1/2 1"1/4 1" 3/4" 1"1/2 1"1/4 1" 3/4" 1"1/2 1"1/4 1" 3/4"
Ø
1"1/2 1" 1"1/2 1" 2" 1"1/2 1" 2" 1"1/2 1"
Ø
FGDR 1"1/2 FGDR 1" FGDR 1"1/2 FGDR 1" FGDR 2" FGDR 1"1/2 FGDR 1" FGDR 2" FGDR 1"1/2 FGDR 1"
included
included
included
included
GAS GOVERNOR AND FILTER
3142523 3142521 3142523 3142521 3142524 3142523 3142521 3142524 3142523 3142521
GAS GOVERNOR AND FILTER CODE TYPE
32
www.ecoflam-burners.com
120
100
55
55
49
49
34
17
500
350
240
175
120
108
70
48
OUTPUT [kW] MIN MAX
TC TL TC TL TC TL TC TL TC TL TC TL TC TL TC TL
120
100
55
55
40
500
350
240
175
120
OUTPUT [kW] MIN MAX
TC TL TC TL TC TL TC TL TC TL
3123954 3123955 3142782 3142783 3142784 3142785 3143287 3143288 3143289 3143290
BURNER BODY BLAST TUBE CODE
3/230-400/50Hz
MAX GAS 500 PR TW
1/230/50Hz
MAX GAS 350 PR TW
MODEL
120
100
500
350
OUTPUT [kW] MIN MAX
TC TL TC TL
3140047 3140048 3140049 3140050
BURNER BODY BLAST TUBE CODE
Two stage progressive mechanical Low NOx class 3 (NOx <80 mg/kWh) - LPG versions
3/230-400/50Hz
MAX GAS 500 PAB TW
1/230/50Hz
MAX GAS 350 PAB TW
1/230/50Hz
MAX GAS 250 PAB TW
1/230/50Hz
MAX GAS 170 PAB TW
1/230/50-60Hz
MAX GAS 120 PAB
MODEL
3142741 3142742 3142743 3142744 3142745 3142746 3142747 3142748 3142749 3142750 3142751 3142752 3143283 3143284 3143285 3143286
BURNER BODY BLAST TUBE CODE
Two stages Low NOx class 3 (NOx <80 mg/kWh) - LPG versions
3/230-400V/50Hz
MAX GAS 500 P TW
1/230V/50Hz
MAX GAS 350 P TW
1/230V/50Hz
MAX GAS 250 P TW
1/230V/50Hz
MAX GAS 170 P TW
1/230V/50-60Hz
MAX GAS 120 P TW
1/230V/50-60Hz
MAX GAS 105 P TW
1/230V/50-60Hz
MAX GAS 70 P TW
1/230V/50-60Hz
MAX GAS 40 P TW
MODEL
One stage Low NOx class 3 (NOx <80 mg/kWh) - LPG versions
360
360
360
360
65
65
65
65
360
360
360
360
360
52
33
360
360
PRESSURE [mbar] MIN MAX
52
33
34
23
15
PRESSURE [mbar] MIN MAX
52
33
34
23
24
24
15
7
PRESSURE [mbar] MIN MAX
3142392
3142392
CODE
3142392
3142392
3123960
3123960
3123960
CODE
3122392
3122392
3123560
3123560
3141885
3141885
3141885
3141885
CODE
MB-DLE 407 350/500
MB-DLE 407 350/500
GAS TRAIN TYPE
MB-DLE 407 350/500
MB-DLE 407 350/500
MB-ZRDLE 405
MB-ZRDLE 405
MB-ZRDLE 405
GAS TRAIN TYPE
MB-DLE 407 350/500
MB-DLE 407 350/500
MB-DLE 405
MB-DLE 405
MBC 65 DLE
MBC 65 DLE
MBC 65 DLE
MBC 65 DLE
GAS TRAIN TYPE
3/4"
3/4"
Ø
3/4"
3/4"
3/4"
3/4"
3/4"
Ø
3/4"
3/4"
3/4"
3/4"
1/2"
1/2"
1/2"
1/2"
Ø
3142431
3142431
LPG KIT CODE
3142431
3142431
3122302
3122302
3122301
LPG KIT CODE
3142431
3142431
3122302
3122302
3122301
3122301
3122301
3122301
LPG KIT CODE
-
-
ADAPT. KIT CODE
-
-
3122300
3122300
-
ADAPT. KIT CODE
-
-
3122300
3122300
-
-
-
-
ADAPT. KIT CODE
www.ecoflam-burners.com
33
All burners 230-400V/50Hz are factory tested at 400V/50Hz instruction manual for adjustments and modifications.
Gas train matching table and pressure drop diagrams for natural gas/LPG are available in the gas train technical documentation.
! three-phase. If main supply is three-phase 230V/50Hz see
• CV: Continuous ventilation version • OEM and special application version only on request • KITSWIRL: Swirl system for flame customized in our Flexshop
AVAILABLE CONFIGURATIONS ON REQUEST
• LPG KIT up to Blu 2000.1 • KIT Wieland plugs • PID modulating KIT and probe • Antivibration coupling and ball valve • Silencer (starting from platform 260)
KIT - ACS (see dedicated pages)
§ VGD Siemens: default blank spring, head pressure 0...22 mbar; from BLU 300.1 change spring and damping (see pag. 53).
EXPORT configuration (others additional options to be added by installer in compliance with local safety regulations): • double solenoid valves VCS Kromschröder: double solenoid valves including min gas pressure switch; • double gas valves with actuators and regulator VGD Siemens§.
EN676 configuration: • GasMultiBloc Dungs: compact double solenoid valve with integrated filter, regulator and min pressure switch up to model BLU 2000.1; • double solenoid valves VCS Kromschröder: double solenoid valves including minimum gas pressure switch + separate gas governor and filter FGDR; • double gas valves with actuators and regulator VGD Siemens§ + gas filter; • KITTC-... Tightness control device must be included over 1200 kW according to EN676; • KITPRES... Maximum pressure switch as option or in compliance with local safety regulations.
BBCH: Burner body with combustion head → TC short head and TL long head GT: Gas train separate → EN676 or Export configuration GTCP: Connection pipe between burner and gas train starting from model 1700.1 FGDR: Gas governor and filter for double solenoid valves VCS Kromschröder FILTER: for double gas valves VGD Siemens KITTC-...: Tightness control kit to be included over 1200 kW according to EN676 KITPRES-...: Maximum pressure switch KIT & ACS can be added according to local rules installations (silencer, ball valve, antivibration coupling...)
BLU range is available in the following versions and is delivered in a modular system of boxes: • PAB: 2 stages • PR: 2 stages progressive mechanical
BLU - Low NOx class 3 (<80 mg/kWh) and class 2 (<120 mg/kWh)
GAS BURNERS
34
www.ecoflam-burners.com
3/230-400/50Hz
BLU 1000.1 PAB
MODEL
Two stages
3/230-400/50Hz
BLU 1500.1 PAB Low NOx
3/230-400/50Hz
BLU 1200.1 PAB Low NOx
3/230-400/50Hz
BLU 1000.1 PAB Low NOx
3/230-400/50Hz
BLU 700.1 PAB Low NOx
MODEL
1550
1100
875
700
245
970
OUTPUT [kW] MIN MAX
300
290
280
270
OUTPUT [kW] MIN MAX
Two stages Low NOx (NOx <80 mg/kWh)
GAS BURNERS BLU
TL
TC
3124015
3124014
BURNER BODY BLAST TUBE CODE
3140313
3140312
TC
TL
3140310
3140309
TC
TL
3140304
3140303
TC
TL
3124013
3124012
TL
TC
BURNER BODY BLAST TUBE CODE
OPT
OPT
SILENCER
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
SILENCER
-
-
CONNECTION PIPE
-
3141842 3142076
-
3141842 3142076
-
-
-
-
-
-
CONNECTION PIPE
500 500 500 500 500 500 500 500 500 500 500 500 500 500
500
500
500
500
25 55 165 25 55 165
500
500
PRESSURE [mbar] MIN MAX
15 30 175 15 30 175 30 60 170 30 60 170 20 30 65 20 30 65 30 40 60 130 30 40 60 130
PRESSURE [mbar] MIN MAX
3141862 3142025 3142024 3141862 3142025 3142024
CODE
3141862 3142025 3142024 3141862 3142025 3142024 3141862 3142025 3142024 3141862 3142025 3142024 3123860 3141862 3142025 3123860 3141862 3142025 3124110 3123860 3141862 3142025 3124110 3123860 3141862 3142025
CODE
VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125
GAS TRAIN TYPE
VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VGD 20.503 VCS 350 VCS 240 VGD 20.503 VCS 350 VCS 240 VGD 40.065 VGD 20.503 VCS 350 VCS 240 VGD 40.065 VGD 20.503 VCS 350 VCS 240
GAS TRAIN TYPE
2" 1"1/2 1" 2" 1"1/2 1"
Ø
2" 1"1/2 1" 2" 1"1/2 1" 2" 1"1/2 1" 2" 1"1/2 1" 2" 2" 1"1/2 2" 2" 1"1/2 2"1/2 2" 2" 1"1/2 2"1/2 2" 2" 1"1/2
Ø
FGDR 2" FGDR 1"1/2 FGDR 1" FGDR 2" FGDR 1"1/2 FGDR 1" FGDR 2" FGDR 1"1/2 FGDR 1" FGDR 2" FGDR 1"1/2 FGDR 1" Filter 2" FGDR 2" FGDR 1"1/2 Filter 2" FGDR 2" FGDR 1"1/2 Filter 2"1/2 Filter 2" FGDR 2" FGDR 1"1/2 Filter 2"1/2 Filter 2" FGDR 2" FGDR 1"1/2
3142524 3142523 3142523 3142524 3142523 3142523
FGDR 2" FGDR 1"1/2 FGDR 1"1/2 FGDR 2" FGDR 1"1/2 FGDR 1"1/2
GAS GOVERNOR AND FILTER CODE TYPE
3142524 3142523 3142521 3142524 3142523 3142521 3142524 3142523 3142521 3142524 3142523 3142521 3121384 3142524 3142523 3121384 3142524 3142523 3124111 3121384 3142524 3142523 3124111 3121384 3142524 3142523
GAS GOVERNOR AND FILTER CODE TYPE
www.ecoflam-burners.com
35
414
342
260
2150
1770
1200
OUTPUT [kW] MIN MAX
3140331
3140330
TC
TL
3140327
3140326
TC
TL
3124017
3124016
TL
TC
BURNER BODY BLAST TUBE CODE
3/230-400/50Hz
BLU 1200.1 PR Low NOx
3/230-400/50Hz
BLU 1000.1 PR Low NOx
3/230-400/50Hz
BLU 700.1 PR Low NOx
MODEL
290
280
270
1100
875
700
OUTPUT [kW] MIN MAX
3140397
3140396
TC
TL
3140391
3142587
TC
TL
3123886
3124030
TL
TC
BURNER BODY BLAST TUBE CODE
Two stage progressive mechanical Low NOx class 3 (NOx <80 mg/kWh)
3/230-400/50Hz
BLU 2000.1 PAB
3/230-400/50Hz
BLU 1700.1 PAB
3/230-400/50Hz
BLU 1200.1 PAB
MODEL
OPT
OPT
OPT
OPT
OPT
OPT
SILENCER
OPT
OPT
OPT
OPT
OPT
OPT
SILENCER
-
-
-
-
-
-
CONNECTION PIPE
3142074
3142069 3142197
3142074
3142069 3142197
3142074
3142069
3142074
3142069
-
-
CONNECTION PIPE
500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500
15 30 175 15 30 175 30 60 170 30 60 170 20 30 65 20 30 65
500 500 500 500 500 500
500
500
500
500
PRESSURE [mbar] MIN MAX
25 35 80 25 35 80 20 45 65 150 20 45 65 150 23 35 60 90 220 23 35 60 90 220
PRESSURE [mbar] MIN MAX
3141862 3142025 3142024 3141862 3142025 3142024 3141862 3142025 3142024 3141862 3142025 3142024 3123860 3141862 3142025 3123860 3141862 3142025
CODE
3123860 3141862 3142025 3123860 3141862 3142025 3142026 3123860 3141862 3142025 3142026 3123860 3141862 3142025 3142026 3124110 3123860 3141862 3142025 3142026 3124110 3123860 3141862 3142025
CODE
VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VGD 20.503 VCS 350 VCS 240 VGD 20.503 VCS 350 VCS 240
GAS TRAIN TYPE
VGD 20.503 VCS 350 VCS 240 VGD 20.503 VCS 350 VCS 240 VGD 40.080 VGD 20.503 VCS 350 VCS 240 VGD 40.080 VGD 20.503 VCS 350 VCS 240 VGD 40.080 VGD 40.065 VGD 20.503 VCS 350 VCS 240 VGD 40.080 VGD 40.065 VGD 20.503 VCS 350 VCS 240
GAS TRAIN TYPE
2" 1"1/2 1" 2" 1"1/2 1" 2" 1"1/2 1" 2" 1"1/2 1" 2" 2" 1"1/2 2" 2" 1"1/2
Ø
2" 2" 1"1/2 2" 2" 1"1/2 DN80 2" 2" 1"1/2 DN80 2" 2" 1"1/2 DN80 2"1/2 2" 2" 1"1/2 DN80 2"1/2 2" 2" 1"1/2
Ø
Filter 2" FGDR 2" FGDR 1"1/2 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter DN65 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter DN65 Filter 2" FGDR 2" FGDR 1"1/2
3142524 3142523 3142521 3142524 3142523 3142521 3142524 3142523 3142521 3142524 3142523 3142521 3121384 3142524 3142523 3121384 3142524 3142523
FGDR 2" FGDR 1"1/2 FGDR 1" FGDR 2" FGDR 1"1/2 FGDR 1" FGDR 2" FGDR 1"1/2 FGDR 1"1/2 FGDR 2" FGDR 1"1/2 FGDR 1"1/2 Filter 2" FGDR 2" FGDR 1"1/2 Filter 2" FGDR 2" FGDR 1"1/2
GAS GOVERNOR AND FILTER CODE TYPE
3121384 3142524 3142523 3121384 3142524 3142523 3142088 3121384 3142524 3142523 3142088 3121384 3142524 3142523 3142088 3124111 3121384 3142524 3142523 3142088 3124111 3121384 3142524 3142523
GAS GOVERNOR AND FILTER CODE TYPE
36
www.ecoflam-burners.com
300
3/230-400/50Hz
BLU 2000.1 PR
3/230-400/50Hz
BLU 1700.1 PR
3/230-400/50Hz
BLU 1200.1 PR
3/230-400/50Hz
BLU 1000.1 PR
MODEL
414
342
260
245
2150
1770
1200
970
OUTPUT [kW] MIN MAX
1550
OUTPUT [kW] MIN MAX
Two stage progressive mechanical
3/230-400/50Hz
BLU 1500.1 PR Low NOx
MODEL
3140400
3124109
3140404
3140403
TC
TL
3140402
3140401
TC
TL
3124034
3124033
TC
TL
3124032
3124031
TL
TC
BURNER BODY BLAST TUBE CODE
TL
TC
BURNER BODY BLAST TUBE CODE
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
SILENCER
OPT
OPT
SILENCER
3142074
3142069 3142197
3142074
3142069 3142197
3142074
3142069
3142074
3142069
-
-
-
-
CONNECTION PIPE
-
3141842 3142076
-
3141842 3142076
CONNECTION PIPE
500 500 500 500 500 500 500 500
25 55 165 25 55 165 25 35 80 25 35 80 20 45 65 150 20 45 65 150 23 35 60 90 220 23 35 60 90 220 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500
500
500
PRESSURE [mbar] MIN MAX
30 40 60 130 30 40 60 130
PRESSURE [mbar] MIN MAX
3141862 3142025 3142024 3141862 3142025 3142024 3123860 3141862 3142025 3123860 3141862 3142025 3142026 3123860 3141862 3142025 3142026 3123860 3141862 3142025 3142026 3124110 3123860 3141862 3142025 3142026 3124110 3123860 3141862 3142025
CODE
3124110 3123860 3141862 3142025 3124110 3123860 3141862 3142025
CODE
VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VGD 20.503 VCS 350 VCS 240 VGD 20.503 VCS 350 VCS 240 VGD 40.080 VGD 20.503 VCS 350 VCS 240 VGD 40.080 VGD 20.503 VCS 350 VCS 240 VGD 40.080 VGD 40.065 VGD 20.503 VCS 350 VCS 240 VGD 40.080 VGD 40.065 VGD 20.503 VCS 350 VCS 240
GAS TRAIN TYPE
VGD 40.065 VGD 20.503 VCS 350 VCS 240 VGD 40.065 VGD 20.503 VCS 350 VCS 240
GAS TRAIN TYPE
2" 1"1/2 1" 2" 1"1/2 1" 2" 2" 1"1/2 2" 2" 1"1/2 DN80 2" 2" 1"1/2 DN80 2" 2" 1"1/2 DN80 DN65 2" 2" 1"1/2 DN80 DN65 2" 2" 1"1/2
Ø
2"1/2 2" 2" 1"1/2 2"1/2 2" 2" 1"1/2
Ø
Filter 2"1/2 Filter 2" FGDR 2" FGDR 1"1/2 Filter 2"1/2 Filter 2" FGDR 2" FGDR 1"1/2
3142524 3142523 3142523 3142524 3142523 3142523 3121384 3142524 3142523 3121384 3142524 3142523 3142088 3121384 3142524 3142523 3142088 3121384 3142524 3142523 3142088 3124111 3121384 3142524 3142523 3142088 3124111 3121384 3142524 3142523
FGDR 2" FGDR 1"1/2 FGDR 1"1/2 FGDR 2" FGDR 1"1/2 FGDR 1"1/2 Filter 2" FGDR 2" FGDR 1"1/2 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter DN65 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter DN65 Filter 2" FGDR 2" FGDR 1"1/2
GAS GOVERNOR AND FILTER CODE TYPE
3124111 3121384 3142524 3142523 3124111 3121384 3142524 3142523
GAS GOVERNOR AND FILTER CODE TYPE
www.ecoflam-burners.com
37
3/230-400/50Hz
BLU 2000.1 PAB
3/230-400/50Hz
BLU 1700.1 PAB
3/230-400/50Hz
BLU 1200.1 PAB
3/230-400/50Hz
BLU 1000.1 PAB
MODEL
3/230-400/50Hz
BLU 1500.1 PAB Low NOx
3/230-400/50Hz
BLU 1200.1 PAB Low NOx
3/230-400/50Hz
BLU 1000.1 PAB Low NOx
3/230-400/50Hz
BLU 700.1 PAB Low NOx
MODEL
1550
1100
875
700
414
342
260
245
2150
1770
1200
970
OUTPUT [kW] MIN MAX
300
290
280
270
OUTPUT [kW] MIN MAX
Two stages - MultiBloc gas train
3140331
3140330
TC
TL
3140327
3140326
TL
TC
3124017
3124016
TC
TL
3124015
3124014
TL
TC
BURNER BODY BLAST TUBE CODE
3140313
3140312
TC
TL
3140310
3140309
TC
TL
3140304
3140303
TC
TL
3124013
3124012
TL
TC
BURNER BODY BLAST TUBE CODE
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
SILENCER
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
SILENCER
3142074
3142074
3142074
3142074
-
-
-
-
CONNECTION PIPE
3142076
3142076
-
-
-
-
-
-
CONNECTION PIPE
360
360
360
360
360
360
360
360
27 35 75 27 35 75 40 50 100 40 50 100 60 85 60 85 75 100 75 100 360
360
360
360
360
360
360
360
PRESSURE [mbar] MIN MAX
17 25 75 17 25 75 35 40 75 35 40 75 35 45 85 35 45 85 60 70 60 70
PRESSURE [mbar] MIN MAX
3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141847 3141846 3141847 3141846 3141847 3141846
CODE
3141847 3141846 3142022 3141847 3141846 3142022 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141847 3141846
CODE
MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 415
GAS TRAIN TYPE
MB-DLE 420 MB-DLE 415 MB-DLE 410 MB-DLE 420 MB-DLE 415 MB-DLE 410 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 415
GAS TRAIN TYPE
2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 2" 1"1/2 2" 1"1/2 2" 1"1/2
Ø
2" 1"1/2 1" 2" 1"1/2 1" 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 2" 1"1/2
Ø
included
included
included
included
included
included
included
included
GAS GOVERNOR AND FILTER
included
included
included
included
included
included
included
included
GAS GOVERNOR AND FILTER
38
www.ecoflam-burners.com
3/230-400/50Hz
BLU 2000.1 PR
3/230-400/50Hz
BLU 1700.1 PR
3/230-400/50Hz
BLU 1200.1 PR
3/230-400/50Hz
BLU 1000.1 PR
MODEL
3/230-400/50Hz
BLU 1500.1 PR Low NOx
3/230-400/50Hz
BLU 1200.1 PR Low NOx
3/230-400/50Hz
BLU 1000.1 PR Low NOx
3/230-400/50Hz
BLU 700.1 PR Low NOx
MODEL
1550
1100
875
700
414
342
260
245
2150
1770
1200
970
OUTPUT [kW] MIN MAX
300
290
280
270
OUTPUT [kW] MIN MAX
Two stage progressive mechanical
3140404
3140403
TC
TL
3140402
3140401
TC
TL
3124034
3124033
TC
TL
3124032
3124031
TL
TC
BURNER BODY BLAST TUBE CODE
3140400
3124109
TC
TL
3140397
3140396
TC
TL
3140391
3142587
TC
TL
3123886
3124030
TL
TC
BURNER BODY BLAST TUBE CODE
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
SILENCER
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
SILENCER
3142074
3142074
3142074
3142074
-
-
-
-
CONNECTION PIPE
3142076
3142076
-
-
-
-
-
-
CONNECTION PIPE
360
360
360
360
360
360
360
360
27 35 75 27 35 75 40 50 100 40 50 100 60 85 60 85 75 100 75 100 360
360
360
360
360
360
360
360
PRESSURE [mbar] MIN MAX
17 25 75 17 25 75 35 40 75 35 40 75 35 45 85 35 45 85 60 70 60 70
PRESSURE [mbar] MIN MAX
3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141847 3141846 3141847 3141846 3141847 3141846
CODE
3141847 3141846 3142022 3141847 3141846 3142022 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141845 3141847 3141846 3141847 3141846
CODE
MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 415
GAS TRAIN TYPE
MB-DLE 420 MB-DLE 415 MB-DLE 410 MB-DLE 420 MB-DLE 415 MB-DLE 410 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB -DLE 412 MB-DLE 420 MB-DLE 415 MB -DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 412 MB-DLE 420 MB-DLE 415 MB-DLE 420 MB-DLE 415
GAS TRAIN TYPE
2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 2" 1"1/2 2" 1"1/2 2" 1"1/2
Ø
2" 1"1/2 1" 2" 1"1/2 1" 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 1"1/4 2" 1"1/2 2" 1"1/2
Ø
included
included
included
included
included
included
included
included
GAS GOVERNOR AND FILTER
included
included
included
included
included
included
included
included
GAS GOVERNOR AND FILTER
www.ecoflam-burners.com
39
1500
1200
875
630
5800
5000
3900
3000
OUTPUT [kW] MIN MAX
3141762
3141761
TC
TL
3141759
3141758
TC
TL
3141757
3141756
TC
TL
3141754
3141753
TL
TC
BURNER BODY BLAST TUBE CODE
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
SILENCER
3142069+ 3142073 3142069 3142197 3142075 3142069+ 3142073 3142069 3142197 3142075 3142069+ 3142073 3142069 3142197 3142075 3142069+ 3142073 3142069 3142197 3142075 3142198 3142070+ 3142073 3142070 3142071 3142075 3142198 3142070+ 3142073 3142070 3142071 3142075 3142198 3142070+ 3142073 3142070 3142071 3142075 3142198 3142070+ 3142073 3142070 3142071 3142075
CONNECTION PIPE
500 500 500 500
100 180 340
500
60
60
500 500 500 500
75 140 250 50
500 500 500 500
500
45
100 180 340 50
500 500 500 500
500
45 75 140 250 35
500 500 500 500
500 500 500
50 90 170 50 90 170 35
500
30
500
500 500 500
35 55 100
30
500
500 500 500
35 55 100 22
500
22
PRESSURE [mbar] MIN MAX
3142026 3124110 3123860
3141869
3142026 3124110 3123860 3142666
3141869
3142026 3124110 3123860 3142666
3141869
3142026 3124110 3123860 3142666
3141869
3142026 3124110 3123860 3142666
3141869
3142026 3124110 3123860
3141869
3142026 3124110 3123860
3141869
3142026 3124110 3123860
3141869
CODE
! ยง VGD Siemens: default blank spring, head pressure 0...22 mbar; from BLU 3000.1 change spring and damping (see pag. 53)
3/400/50Hz
BLU 6000.1 PR
3/400/50Hz
BLU 5000.1 PR
3/400/50Hz
BLU 4000.1 PR
3/400/50Hz
BLU 3000.1 PR
MODEL
Two stage progressive mechanical
VGD 40.080 VGD 40.065 VGD 20.503
VGD 40.100
VGD 40.080 VGD 40.065 VGD 20.503 VGD 40.125
VGD 40.100
VGD 40.080 VGD 40.065 VGD 20.503 VGD 40.125
VGD 40.100
VGD 40.080 VGD 40.065 VGD 20.503 VGD 40.125
VGD 40.100
VGD 40.080 VGD 40.065 VGD 20.503 VGD 40.125
VGD 40.100
VGD 40.080 VGD 40.065 VGD 20.503
VGD 40.100
VGD 40.080 VGD 40.065 VGD 20.503
VGD 40.100
VGD 40.080 VGD 40.065 VGD 20.503
VGD 40.100
GAS TRAIN (ยง) TYPE
DN80 DN65 2"
DN100
DN80 DN65 2" DN125
DN100
DN80 DN65 2" DN125
DN100
DN80 DN65 2" DN125
DN100
DN80 DN65 2" DN125
DN100
DN80 DN65 2"
DN100
DN80 DN65 2"
DN100
DN80 DN65 2"
DN100
ร
3142088 3124111 3121384
3142205
3142088 3124111 3121384 3142206
3142205
3142088 3124111 3121384 3142206
3142205
3142088 3124111 3121384 3142206
3142205
3142088 3124111 3121384 3142206
3142205
3142088 3124111 3121384
3142205
3142088 3124111 3121384
3142205
3142088 3124111 3121384
3142205
Filter DN80 Filter DN65 Filter 2"
Filter DN100
Filter DN80 Filter DN65 Filter 2" Filter DN125
Filter DN100
Filter DN80 Filter DN65 Filter 2" Filter DN125
Filter DN100
Filter DN80 Filter DN65 Filter 2" Filter DN125
Filter DN100
Filter DN80 Filter DN65 Filter 2" Filter DN125
Filter DN100
Filter DN80 Filter DN65 Filter 2"
Filter DN100
Filter DN80 Filter DN65 Filter 2"
Filter DN100
Filter DN80 Filter DN65 Filter 2"
Filter DN100
GAS GOVERNOR AND FILTER CODE TYPE
40
www.ecoflam-burners.com
3/400/50Hz
4000
3690
2700
2500
2000
1500
17000
15000
13000
10500
8500
7500
OUTPUT [kW] MIN MAX
TC
TC
TC
TC
TC
TC
3143752
3143751
3143750
3143749
3143748
3143747
BURNER BODY BLAST TUBE CODE
OPT
OPT
OPT
OPT
OPT
OPT
SILENCER
3142422+ 3142425 3142422 3142424 3142423 3142422+ 3142425 3142422 3142424 3142423 3142422+ 3142425 3142422 3142424 3142423 3142422+ 3142425 3142422 3142424 3142422+ 3142425 3142422 3142424 3142422+ 3142425 3142422
CONNECTION PIPE
330
210
230 450
150
230 420
175
165 290 550
115
110 210 410
85
75 140 280
60
500
500
500
500
500
500
PRESSURE [mbar] MIN MAX
3141869
3142666
3141869 3142026
3142666
3141869 3142026
3142666
3141869 3142026 3124110
3142666
3141869 3142026 3124110
3142666
3141869 3142026 3124110
3142666
CODE
see accessories page
see accessories page
see accessories page
see accessories page
see accessories page
see accessories page
Tightness control
Modulation kit
Probe
LPG kit
Adaptor kit for gas train
Additional gas accessories
BLU - DUOBLOCK AND ELECTRONIC BURNERS Versions from 2 to 25 MW are available on request for selected output to match main boilers and industry application.
see accessories page
Silencer
DESCRIPTION
KIT - ACCESSORIES
! ยง VGD Siemens: default blank spring, head pressure 0...22 mbar; from BLU 3000.1 change spring and damping (see pag. 53)
3/400/50Hz
BLU 18000.1 PR
3/400/50Hz
BLU 15000.1 PR
3/400/50Hz
BLU 12000.1 PR
3/400/50Hz
BLU 10000.1 PR
3/400/50Hz
BLU 8000.1 PR
BLU 7000.1 PR
MODEL
VGD 40.100
VGD 40.125
VGD 40.100 VGD 40.080
VGD 40.125
VGD 40.100 VGD 40.080
VGD 40.125
VGD 40.100 VGD 40.080 VGD 40.065
VGD 40.125
VGD 40.100 VGD 40.080 VGD 40.065
VGD 40.125
VGD 40.100 VGD 40.080 VGD 40.065
VGD 40.125
GAS TRAIN (ยง) TYPE
DN100
DN125
DN100 DN80
DN125
DN100 DN80
DN125
DN100 DN80 DN65
DN125
DN100 DN80 DN65
DN125
DN100 DN80 DN65
DN125
ร
3142205
3142206
3142205 3142088
3142206
3142205 3142088
3142206
3142205 3142088 3124111
3142206
3142205 3142088 3124111
3142206
3142205 3142088 3124111
3142206
Filter DN100
Filter DN125
Filter DN100 Filter DN80
Filter DN125
Filter DN100 Filter DN80
Filter DN125
Filter DN100 Filter DN80 Filter DN65
Filter DN125
Filter DN100 Filter DN80 Filter DN65
Filter DN125
Filter DN100 Filter DN80 Filter DN65
Filter DN125
GAS GOVERNOR AND FILTER CODE TYPE
www.ecoflam-burners.com
41
All burners 230-400V/50Hz are factory tested at 400V/50Hz instruction manual for adjustments and modifications.
Gas train matching table and pressure drop diagrams for natural gas/LPG are available in the gas train technical documentation.
! three-phase. If main supply is three-phase 230V/50Hz see
• CV: Continuous ventilation version • OEM and special application version only on request • KITSWIRL: Swirl system for flame customized in our Flexshop
AVAILABLE CONFIGURATIONS ON REQUEST
• LPG KIT up to MULTICALOR 200.1 • KIT automatic fuel changeover • PID modulating KIT and probe • KIT Wieland plugs • Antivibration coupling and ball valve • Silencer (starting from platform 260)
KIT - ACS (see dedicated pages)
§ VGD Siemens: default blank spring, head pressure 0...22 mbar; from MULTICALOR 300.1 change spring and damping (see pag. 53).
EXPORT configuration (others additional options to be added by installer in compliance with local safety regulations): • Double solenoid valves VCS Kromschröder: double solenoid valves including min gas pressure switch • Double gas valves with actuators and regulator VGD Siemens§
EN676 configuration: • GasMultiBloc Dungs: compact double solenoid valve with integrated filter, regulator and min pressure switch up to model MULTICALOR 200.1; • double solenoid valves VCS Kromschröder: double solenoid valves including minimum gas pressure switch + separate gas governor and filter FGDR; • double gas valves with actuators and regulator VGD Siemens§ + gas filter; • KITTC-... Tightness control device must be included over 1200 kW according to EN676; • KITPRES... Maximum pressure switch as option or in compliance with local safety regulations.
Standard version running on manual fuel selection mode and on request kit for automatic fuel changeover. The automatic changeover system can be triggered by a gas pressure switch or by a timer.
BBCH: Burner body with combustion head → TC short head and TL long head. Easy maintenance system with hinge flange for models 1500.1 - 1800.1. GT: Gas train separate → EN676 or Export configuration GTCP: Connection pipe between burner and gas train starting from model 170.1 FGDR: Gas governor and filter for double solenoid valves VCS Kromschröder FILTER for double gas valves VGD Siemens KITTC-...: Tightness control kit to be included over 1200 kW according to EN676 KITPRES...: Maximum pressure switch KIT & ACS can be added according to local rules installations (silencer, ball valve, antivibration coupling...)
MULTICALOR is available in the following versions and is delivered in a modular system of boxes: • AB: 2 stages gas and light oil / soft start light oil • PR-AB: 2 stage progressive mechanical gas / 2 stages light oil - soft start light oil • PR: 2 stage progressive mechanical gas - oil
MULTICALOR
DUAL FUEL BURNERS (GAS/LIGHT OIL)
42
www.ecoflam-burners.com
3/230-400/50Hz
MULTICALOR 200.1
3/230-400/50Hz
MULTICALOR 170.1
3/230-400/50Hz
MULTICALOR 140
3/230-400/50Hz
MULTICALOR 100
3/230-400/50Hz
MULTICALOR 70
3/230-400/50Hz
MULTICALOR 45
MODEL
414
342
400
300
250
190
2150
1770
1300
1000
700
500
OUTPUT [kW] MIN MAX
Two stages gas / Two stages light oil
3142631
3142630
TC
TL
3142629
3142628
TC
TL
3140438
3140439
TC
TL
3140432
3140433
TC
TL
3140430
3140431
TC
TL
3140428
3140429
TL
TC
BURNER BODY BLAST TUBE CODE
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
-
-
SILENCER
DUAL FUEL BURNERS (GAS/LIGHT OIL) MULTICALOR
3142075
3142069 3142197
3142075
3142069 3142197
3142075
3142069
3142075
3142069
-
-
-
-
-
-
-
-
CONNECTION PIPE
17 90 17 90 15 30 170 15 30 170 25 40 165 25 40 165 25 35 80 25 35 80 20 45 65 150 20 45 65 150 23 35 60 90 220 23 35 60 90 220 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500
500
500
500
500
500
500
PRESSURE [mbar] MIN MAX
3142025 3142024 3142025 3142024 3141862 3142025 3142024 3141862 3142025 3142024 3141862 3142025 3142024 3141862 3142025 3142024 3123860 3141862 3142025 3123860 3141862 3142025 3142026 3123860 3141862 3142025 3142026 3123860 3141862 3142025 3142026 3124110 3123860 3141862 3142025 3142026 3124110 3123860 3141862 3142025
CODE
VCS 240 VCS 125 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VCS 350 VCS 240 VCS 125 VGD 20.503 VCS 350 VCS 240 VGD 20.503 VCS 350 VCS 240 VGD 40.080 VGD 20.503 VCS 350 VCS 240 VGD 40.080 VGD 20.503 VCS 350 VCS 240 VGD 40.080 VGD 40.065 VGD 20.503 VCS 350 VCS 240 VGD 40.080 VGD 40.065 VGD 20.503 VCS 350 VCS 240
GAS TRAIN TYPE
1"1/2 1" 1"1/2 1" 2" 1"1/2 1" 2" 1"1/2 1" 2" 1"1/2 1" 2" 1"1/2 1" 2" 2" 1"1/2 2" 2" 1"1/2 DN80 2" 2" 1"1/2 DN80 2" 2" 1"1/2 DN80 2"1/2 2" 2" 1"1/2 DN80 2"1/2 2" 2" 1"1/2
Ø
3142523 3142521 3142523 3142521 3142524 3142523 3142521 3142524 3142523 3142521 3142524 3142523 3142523 3142524 3142523 3142523 3121384 3142524 3142523 3121384 3142524 3142523 3142088 3121384 3142524 3142523 3142088 3121384 3142524 3142523 3142088 3124111 3121384 3142524 3142523 3142088 3124111 3121384 3142524 3142523
FGDR 1"1/2 FGDR 1" FGDR 1"1/2 FGDR 1" FGDR 2" FGDR 1"1/2 FGDR 1" FGDR 2" FGDR 1"1/2 FGDR 1" FGDR 2" FGDR 1"1/2 FGDR 1"1/2 FGDR 2" FGDR 1"1/2 FGDR 1"1/2 Filter 2" FGDR 2" FGDR 1"1/2 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter DN65 Filter 2" FGDR 2" FGDR 1"1/2 Filter DN80 Filter DN65 Filter 2" FGDR 2" FGDR 1"1/2
GAS GOVERNOR AND FILTER CODE TYPE
www.ecoflam-burners.com
43
3/230-400/50Hz
MULTICALOR 200.1 PR-AB
3/230-400/50Hz
MULTICALOR 170.1 PR-AB
3/230-400/50Hz
MULTICALOR 140 PR-AB
3/230-400/50Hz
MULTICALOR 100 PR-AB
3/230-400/50Hz
MULTICALOR 70 PR-AB
MODEL
414
342
250
200
190
2150
1770
1300
1000
700
OUTPUT [kW] MIN MAX
3142641
3142640
TC
TL
3142639
3142638
TC
TL
3142637
3142636
TC
TL
3142635
3142634
TC
TL
3142633
3142632
TL
TC
BURNER BODY BLAST TUBE CODE
Two stage progressive mechanical gas / Two stages light oil
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
SILENCER
500
80
3142075
35
500 500 500
90
500 220
60
3142197
500
500 23
220 3142069
500
500 90
60 3142075
500 500
23 35
500
3142069
500
65 150
500
45
500 500
150 20
500
500
65
45
500 500
80 20
500
35
500
500
35 25
3123860
3142025
3141862
3123860
3124110
3142026
3142025
3141862
3123860
3124110
3142026
3142025
3141862
3123860
3142026
3142025
3141862
3123860
3142026
3142025
3141862
3123860
3142025
3141862
3142024 500
3142025
3141862
25
500
165
40
25
3142024
3142025
500
40 165
3142024 3141862
3142025
3141862
3142024
3142025
25
500
500
3141862
CODE
170
30
15
170
30
15
PRESSURE [mbar] MIN MAX
3142197
3142075
3142069
3142075
3142069
-
-
-
-
-
-
CONNECTION PIPE
VCS 240
VCS 350
VGD 20.503
VGD 40.065
VGD 40.080
VCS 240
VCS 350
VGD 20.503
VGD 40.065
VGD 40.080
VCS 240
VCS 350
VGD 20.503
VGD 40.080
VCS 240
VCS 350
VGD 20.503
VGD 40.080
VCS 240
VCS 350
VGD 20.503
VCS 240
VCS 350
VGD 20.503
VCS 125
VCS 240
VCS 350
VCS 125
VCS 240
VCS 350
VCS 125
VCS 240
VCS 350
VCS 125
VCS 240
VCS 350
GAS TRAIN TYPE
1"1/2
2"
2"
2"1/2
DN80
1"1/2
2"
2"
2"1/2
DN80
1"1/2
2"
2"
DN80
1"1/2
2"
2"
DN80
1"1/2
2"
2"
1"1/2
2"
2"
1"
1"1/2
2"
1"
1"1/2
2"
1"
1"1/2
2"
1"
1"1/2
2"
Ø
3142523
3142524
3121384
3124111
3142088
3142523
3142524
3121384
3124111
3142088
3142523
3142524
3121384
3142088
3142523
3142524
3121384
3142088
3142523
3142524
3121384
3142523
3142524
3121384
3142523
3142523
3142524
3142523
3142523
3142524
3142521
3142523
3142524
3142521
3142523
3142524
FGDR 1"1/2
FGDR 2"
Filter 2"
Filter DN65
Filter DN80
FGDR 1"1/2
FGDR 2"
Filter 2"
Filter DN65
Filter DN80
FGDR 1"1/2
FGDR 2"
Filter 2"
Filter DN80
FGDR 1"1/2
FGDR 2"
Filter 2"
Filter DN80
FGDR 1"1/2
FGDR 2"
Filter 2"
FGDR 1"1/2
FGDR 2"
Filter 2"
FGDR 1"1/2
FGDR 1"1/2
FGDR 2"
FGDR 1"1/2
FGDR 1"1/2
FGDR 2"
FGDR 1"
FGDR 1"1/2
FGDR 2"
FGDR 1"
FGDR 1"1/2
FGDR 2"
GAS GOVERNOR AND FILTER CODE TYPE
44
www.ecoflam-burners.com
3/230-400/50Hz
MULTICALOR 200.1
3/230-400/50Hz
MULTICALOR 170.1
3/230-400/50Hz
MULTICALOR 140
3/230-400/50Hz
MULTICALOR 100
3/230-400/50Hz
MULTICALOR 70
3/230-400/50Hz
MULTICALOR 45
MODEL
414
342
400
300
250
190
2150
1770
1300
1000
700
500
OUTPUT [kW] MIN MAX
3142631
3142630
TC
TL
3142629
3142628
TC
TL
3140438
3140439
TC
TL
3140432
3140433
TC
TL
3140430
3140431
TC
TL
3140428
3140429
TL
TC
BURNER BODY BLAST TUBE CODE
Two stages gas / Two stages light oil - MultiBloc gas train
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
SILENCER
3142075
3142075
3142075
3142075
-
-
-
-
-
-
-
-
CONNECTION PIPE
100
75
100
75
85
60
360
360
360
360
3141846
3141847
3141846
3141847
3141846
3141847
3141846
3141847 85
60
3141846 3141845
360
3141847
100
50
40
3141845
3141846 360
50 100
3141845 3141847
3141846
3141847
75
360
40
35
27
3141845
3141846
360
35 75
3142022 3141847
3141846
75
360
3141847
27
25
17
3142022
3141846
25 75
3141847
17 360
3141843
3142022
85
50
3141845
360
3141846
30
3141843
3142022
15
85
50
3141845
30 360
3141846
CODE
15
PRESSURE [mbar] MIN MAX
MB-DLE 415
MB-DLE 420
MB-DLE 415
MB-DLE 420
MB-DLE 415
MB-DLE 420
MB-DLE 415
MB-DLE 420
MB-DLE 412
MB-DLE 415
MB-DLE 420
MB-DLE 412
MB-DLE 415
MB-DLE 420
MB-DLE 412
MB-DLE 415
MB-DLE 420
MB-DLE 412
MB-DLE 415
MB-DLE 420
MB-DLE 410
MB-DLE 415
MB-DLE 420
MB-DLE 410
MB-DLE 415
MB-DLE 420
MB-DLE 407
MB-DLE 410
MB-DLE 412
MB-DLE 415
MB-DLE 407
MB-DLE 410
MB-DLE 412
MB-DLE 415
GAS TRAIN TYPE
1"1/2
2"
1"1/2
2"
1"1/2
2"
1"1/2
2"
1"1/4
1"1/2
2"
1"1/4
1"1/2
2"
1"1/4
1"1/2
2"
1"1/4
1"1/2
2"
1"
1"1/2
2"
1"
1"1/2
2"
3/4"
1"
1"1/4
1"1/2
3/4"
1"
1"1/4
1"1/2
Ø
included
included
included
included
included
included
included
included
included
included
included
included
GAS GOVERNOR AND FILTER
www.ecoflam-burners.com
45
414
342
250
200
190
2150
1770
1300
1000
700
OUTPUT [kW] MIN MAX
3142641
3142640
TC
TL
3142639
3142638
TC
TL
3142637
3142636
TC
TL
3142635
3142634
TC
TL
3142633
3142632
TL
TC
BURNER BODY BLAST TUBE CODE
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
SILENCER
3142075
3142075
3142075
3142075
-
-
-
-
-
-
CONNECTION PIPE
250
300
400
342
414
MULTICALOR 100 PR - 3/230-400/50Hz
MULTICALOR 140 PR - 3/230-400/50Hz
MULTICALOR 170.1 PR - 3/230-400/50Hz
MULTICALOR 200.1 PR - 3/230-400/50Hz
MIN
MULTICALOR 70 PR - 3/230-400/50Hz
MODEL
2150
1770
1300
1000
700
OUTPUT [kW] MAX
TL
TL
TL
TL
TL
100
75
100
75
85
60
85
on request
on request
on request
on request
OPT
OPT
OPT
OPT
OPT
SILENCER
360
360
360
360
3141846
3141847
3141846
3141847
3141846
3141847
3141846
3141845 3141847
3141846
3141847
60
360
100
50
40
3141845
3141846
360
50 100
3141847
40
3141846 3141845
360
3141847
75
35
27
3141845
3141846
75
3141847
35 360
27
3141846
3141847
3142022
3141846
3142022
360
360
3141847
CODE
75
25
17
75
25
17
PRESSURE [mbar] MIN MAX
on request
BURNER BODY BLAST TUBE CODE
Two stage progressive mechanical gas / Two stage progressive mechanical light oil - Only body
3/230-400/50Hz
MULTICALOR 200.1 PR-AB
3/230-400/50Hz
MULTICALOR 170.1 PR-AB
3/230-400/50Hz
MULTICALOR 140 PR-AB
3/230-400/50Hz
MULTICALOR 100 PR-AB
3/230-400/50Hz
MULTICALOR 70 PR-AB
MODEL
Two stage progressive mechanical gas / Two stages light oil - MultiBloc gas train
MB-DLE 415
MB-DLE 420
MB-DLE 415
MB-DLE 420
MB-DLE 415
MB-DLE 420
MB-DLE 415
MB-DLE 420
MB-DLE 412
MB-DLE 415
MB-DLE 420
MB-DLE 412
MB-DLE 415
MB-DLE 420
MB-DLE 412
MB-DLE 415
MB-DLE 420
MB-DLE 412
MB-DLE 415
MB-DLE 420
MB-DLE 410
MB-DLE 415
MB-DLE 420
MB-DLE 410
MB-DLE 415
MB-DLE 420
GAS TRAIN TYPE
1"1/2
2"
1"1/2
2"
1"1/2
2"
1"1/2
2"
1"1/4
1"1/2
2"
1"1/4
1"1/2
2"
1"1/4
1"1/2
2"
1"1/4
1"1/2
2"
1"
1"1/2
2"
1"
1"1/2
2"
Ø
included
included
included
included
included
included
included
included
included
included
GAS GOVERNOR AND FILTER
46
www.ecoflam-burners.com
1500
1200
875
630
5800
5000
3900
3000
OUTPUT [kW] MIN MAX
3143772
3143771
TC
TL
3143770
3143769
TC
TL
3143768
3143767
TC
TL
3143766
3143765
TL
TC
BURNER BODY BLAST TUBE CODE
OPT
OPT
OPT
OPT
OPT
OPT
OPT
OPT
SILENCER
3142069+ 3142073 3142069 3142197 3142075 3142069+ 3142073 3142069 3142197 3142075 3142069+ 3142073 3142069 3142197 3142075 3142069+ 3142073 3142069 3142197 3142075 3142198 3142070+ 3142073 3142070 3142071 3142075 3142198 3142070+ 3142073 3142070 3142071 3142075 3142198 3142070+ 3142073 3142070 3142071 3142075 3142198 3142070+ 3142073 3142070 3142071 3142075
CONNECTION PIPE
500 500 500 500
100 180 340
500
60
60
500 500 500 500
75 140 250 50
500 500 500 500
500
45
100 180 340 50
500 500 500 500
500
45 75 140 250 35
500 500 500 500
500 500 500
50 90 170 50 90 170 35
500
30
500
500 500 500
35 55 100
30
500
500 500 500
35 55 100 22
500
22
PRESSURE [mbar] MIN MAX
3142026 3124110 3123860
3141869
3142026 3124110 3123860 3142666
3141869
3142026 3124110 3123860 3142666
3141869
3142026 3124110 3123860 3142666
3141869
3142026 3124110 3123860 3142666
3141869
3142026 3124110 3123860
3141869
3142026 3124110 3123860
3141869
3142026 3124110 3123860
3141869
CODE
! ยง VGD Siemens: default blank spring, head pressure 0...22 mbar; from MULTICALOR 3000.1 change spring and damping (see pag. 53)
3/400/50Hz
MULTICALOR 600.1 PR
3/400/50Hz
MULTICALOR 500.1 PR
3/400/50Hz
MULTICALOR 400.1 PR
3/400/50Hz
MULTICALOR 300.1 PR
MODEL
Two stage progressive mechanical gas / Two stage progressive mechanical light oil
VGD 40.080 VGD 40.065 VGD 20.503
VGD 40.100
VGD 40.080 VGD 40.065 VGD 20.503 VGD 40.125
VGD 40.100
VGD 40.080 VGD 40.065 VGD 20.503 VGD 40.125
VGD 40.100
VGD 40.080 VGD 40.065 VGD 20.503 VGD 40.125
VGD 40.100
VGD 40.080 VGD 40.065 VGD 20.503 VGD 40.125
VGD 40.100
VGD 40.080 VGD 40.065 VGD 20.503
VGD 40.100
VGD 40.080 VGD 40.065 VGD 20.503
VGD 40.100
VGD 40.080 VGD 40.065 VGD 20.503
VGD 40.100
GAS TRAIN (ยง) TYPE
DN80 DN65 2"
DN100
DN80 DN65 2" DN125
DN100
DN80 DN65 2" DN125
DN100
DN80 DN65 2" DN125
DN100
DN80 DN65 2" DN125
DN100
DN80 DN65 2"
DN100
DN80 DN65 2"
DN100
DN80 DN65 2"
DN100
ร
3142088 3124111 3121384
3142205
3142088 3124111 3121384 3142206
3142205
3142088 3124111 3121384 3142206
3142205
3142088 3124111 3121384 3142206
3142205
3142088 3124111 3121384 3142206
3142205
3142088 3124111 3121384
3142205
3142088 3124111 3121384
3142205
3142088 3124111 3121384
3142205
Filter DN80 Filter DN65 Filter 2''
Filter DN100
Filter DN80 Filter DN65 Filter 2'' Filter DN125
Filter DN100
Filter DN80 Filter DN65 Filter 2'' Filter DN125
Filter DN100
Filter DN80 Filter DN65 Filter 2'' Filter DN125
Filter DN100
Filter DN80 Filter DN65 Filter 2" Filter DN125
Filter DN100
Filter DN80 Filter DN65 Filter 2"
Filter DN100
Filter DN80 Filter DN65 Filter 2"
Filter DN100
Filter DN80 Filter DN65 Filter 2"
Filter DN100
GAS GOVERNOR AND FILTER CODE TYPE
www.ecoflam-burners.com
47
4000
3690
2700
2500
2000
1500
17000
15000
13000
10500
8500
7500
OUTPUT [kW] MIN MAX
TC
TC
TC
TC
TC
TC
3143778
3143777
3143776
3143775
3143774
3143773
BURNER BODY BLAST TUBE CODE
OPT
OPT
OPT
OPT
OPT
OPT
SILENCER
3142422+ 3142425 3142422 330
210
230 450
150
3142422+ 3142425 3142422 3142424
230 420
175
3142422+ 3142425 3142422 3142424
165 290 550
115
3142422+ 3142425 3142422 3142424 3142423
110 210 410
85
3142422+ 3142425 3142422 3142424 3142423
75 140 280
500
500
500
500
500
500
60
3142422+ 3142425 3142422 3142424 3142423
PRESSURE [mbar] MIN MAX
CONNECTION PIPE
3141869
3142666
3141869 3142026
3142666
3141869 3142026
3142666
3141869 3142026 3124110
3142666
3141869 3142026 3124110
3142666
3141869 3142026 3124110
3142666
CODE
see accessories page see accessories page see accessories page see accessories page see accessories page see accessories page see accessories page see accessories page
MULTICALOR - DUOBLOCK AND ELECTRONIC BURNERS Versions from 2 to 25 MW are available on request for selected output to match main boilers and industry application.
Silencer Tightness control Modulation kit Probe LPG kit Additional gas accessories Automatic fuel changeover kit Oil pumping unit
DESCRIPTION
KIT - ACCESSORIES
! ยง VGD Siemens: default blank spring, head pressure 0...22 mbar; from MULTICALOR 3000.1 change spring and damping (see pag. 53)
3/400/50Hz
MULTICALOR 1800.1 PR
3/400/50Hz
MULTICALOR 1500.1 PR
3/400/50Hz
MULTICALOR 1200.1 PR
3/400/50Hz
MULTICALOR 1000.1 PR
3/400/50Hz
MULTICALOR 800.1 PR
3/400/50Hz
MULTICALOR 700.1 PR
MODEL
VGD 40.100
VGD 40.125
VGD 40.100 VGD 40.080
VGD 40.125
VGD 40.100 VGD 40.080
VGD 40.125
VGD 40.100 VGD 40.080 VGD 40.065
VGD 40.125
VGD 40.100 VGD 40.080 VGD 40.065
VGD 40.125
VGD 40.100 VGD 40.080 VGD 40.065
VGD 40.125
GAS TRAIN (ยง) TYPE
DN100
DN125
DN100 DN80
DN125
DN100 DN80
DN125
DN100 DN80 DN65
DN125
DN100 DN80 DN65
DN125
DN100 DN80 DN65
DN125
ร
3142205
3142206
3142205 3142088
3142206
3142205 3142088
3142206
3142205 3142088 3124111
3142206
3142205 3142088 3124111
3142206
3142205 3142088 3124111
3142206
Filter DN100
Filter DN125
Filter DN100 Filter DN80
Filter DN125
Filter DN100 Filter DN80
Filter DN125
Filter DN100 Filter DN80 Filter DN65
Filter DN125
Filter DN100 Filter DN80 Filter DN65
Filter DN125
Filter DN100 Filter DN80 Filter DN65
Filter DN125
GAS GOVERNOR AND FILTER CODE TYPE
48
www.ecoflam-burners.com
All burners 230-400V/50Hz are factory tested at 400V/50Hz instruction manual for adjustments and modifications.
Gas train matching table and pressure drop diagrams for natural gas/LPG are available in the gas train technical documentation.
! three-phase. If main supply is three-phase 230V/50Hz see
• CV: Continuous ventilation version • OEM and special application version only on request • KITSWIRL: Swirl system for flame customized in our Flexshop
AVAILABLE CONFIGURATIONS ON REQUEST
• KIT automatic fuel changeover • PID modulating KIT and probe • KIT Wieland plugs • Antivibration coupling and ball valve • Silencer (starting from platform 260)
KIT - ACS (see dedicated pages)
§ VGD Siemens: default blank spring, head pressure 0...22 mbar; from MULTIFLAM 300.1 change spring and damping (see pag. 53).
EN676 configuration: • double gas valves with actuators and regulator VGD Siemens§ + gas filter; • KITTC-... Tightness control device must be included over 1200 kW according to EN676; • KITPRES... Maximum pressure switch as option or in compliance with local safety regulations.
Standard version running on manual fuel selection mode and on request kit for automatic fuel changeover. The automatic changeover system can be triggered by a gas pressure switch or by a timer.
BBCH: Burner body with combustion head → TC short head and TL long head in D version for heavy oil with max visc 50°E at 50°C. Electrical pre-heater preassembled into the burner body. All burners body are delivered with sliding bar system up to model 1200.1 and with hinge flange for models 200.1 and 1500.1 - 1800.1. GT: Gas train separate → EN676 or Export configuration GTCP: Connection pipe between burner and gas train starting from model 170.1 FGDR: Gas governor and filter for double solenoid valves VCS Kromschröder FILTER for double gas valves VGD Siemens KITTC-...: Tightness control kit to be included over 1200 kW according to EN676 KITPRES...: Maximum pressure switch KIT & ACS can be added according to local rules installations (silencer, ball valve, antivibration coupling...)
MULTIFLAM range is available in the following versions and is delivered in a modular system of boxes: • PAB: 2 stages gas and heavy oil / soft start heavy oil • PR: 2 stage progressive mechanical gas - heavy oil
MULTIFLAM - Max visc. 50°E at 50°C
DUAL FUEL BURNERS (GAS/HEAVY OIL)
www.ecoflam-burners.com
49
414
2150
OUTPUT [kW] MIN MAX
TL
TC
3142670
3142669
BURNER BODY BLAST TUBE CODE
OPT
OPT
SILENCER
55 100
3142935 3143080
35
100
3143080 -
55
35
500
500
500
500
500
500
PRESSURE [mbar] MIN MAX
3142935
-
CONNECTION PIPE
875
630
3900
3000
OUTPUT [kW] MIN MAX
3143782
3143781
TC
TL
3143780
3143779
TL
TC
BURNER BODY BLAST TUBE CODE
OPT
OPT
OPT
OPT
SILENCER
90 170
3142935 3143080
170
3143080
50
90
3142935
-
50
-
30
30
3142073
3142073
55 100
3142935 3143080
35
100
3143080 -
55
3142935 22
35
-
3142073
22
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
PRESSURE [mbar] MIN MAX
3142073
CONNECTION PIPE
3123860
3124110
3142026
3141869
3123860
3124110
3142026
3141869
3123860
3124110
3142026
3141869
3123860
3124110
3142026
3141869
CODE
3123860
3124110
3142026
3123860
3124110
3142026
CODE
! § VGD Siemens: default blank spring, head pressure 0...22 mbar; from MULTIFLAM 3000.1 change spring and damping (see pag. 53)
3/400/50Hz
MULTIFLAM 400.1 PR
3/400/50Hz
MULTIFLAM 300.1 PR
MODEL
Two stage progressive mechanical gas / Two stage progressive mechanical heavy oil - 50°E fuel viscosity at 50°C
3/230-400/50Hz
MULTIFLAM 200.1
MODEL
Two stages gas / Two stages heavy oil - 50°E fuel viscosity at 50°C
DUAL FUEL BURNERS (GAS/HEAVY OIL) MULTIFLAM - Max visc. 50°E at 50°C
VGD 20.503
VGD 40.065
VGD 40.080
VGD 40.100
VGD 20.503
VGD 40.065
VGD 40.080
VGD 40.100
VGD 20.503
VGD 40.065
VGD 40.080
VGD 40.100
VGD 20.503
VGD 40.065
VGD 40.080
VGD 40.100
GAS TRAIN TYPE
VGD 20.503
VGD 40.065
VGD 40.080
VGD 20.503
VGD 40.065
VGD 40.080
GAS TRAIN TYPE
2"
DN65
DN80
DN100
2"
DN65
DN80
DN100
2"
DN65
DN80
DN100
2"
DN65
DN80
DN100
Ø
2"
DN65
DN80
2"
DN65
DN80
Ø
Filter 2"
Filter DN65
Filter DN80
Filter 2"
Filter DN65
Filter DN80
3121384
3124111
3142088
3142205
3121384
3124111
3142088
3142205
3121384
3124111
3142088
3142205
3121384
3124111
3142088
3142205
Filter 2"
Filter DN65
Filter DN80
Filter DN100
Filter 2"
Filter DN65
Filter DN80
Filter DN100
Filter 2"
Filter DN65
Filter DN80
Filter DN100
Filter 2"
Filter DN65
Filter DN80
Filter DN100
GAS GOVERNOR AND FILTER CODE TYPE
3121384
3124111
3142088
3121384
3124111
3142088
GAS GOVERNOR AND FILTER CODE TYPE
50
www.ecoflam-burners.com
5800
5000
3143786
3143785
TC
TL
3143784
3143783
TL
TC
BURNER BODY BLAST TUBE CODE
OPT
OPT
OPT
OPT
SILENCER
180 340
3142935 3143080
60
3142073 100
50
3143105
-
340
3143080
180
60
3142073
3142935
50
3143105
100
250
3143080
-
140
3142935
45
3142073 75
35
3143105
-
250
140
3142935 3143080
75
45
3142073 -
35
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
PRESSURE [mbar] MIN MAX
3143105
CONNECTION PIPE
3123860
3124110
3142026
3141869
3142666
3123860
3124110
3142026
3141869
3142666
3123860
3124110
3142026
3141869
3142666
3123860
3124110
3142026
3141869
3142666
CODE
Silencer Tightness control Modulation kit Probe LPG kit Additional gas accessories Automatic fuel changeover kit Oil heating pumping unit
DESCRIPTION
KIT - ACCESSORIES
see accessories page see accessories page see accessories page see accessories page see accessories page see accessories page see accessories page see accessories page
! ยง VGD Siemens: default blank spring, head pressure 0...22 mbar; from MULTIFLAM 3000.1 change spring and damping (see pag. 53)
3/400/50Hz
1500
MULTIFLAM 600.1 PR
3/400/50Hz
1200
OUTPUT [kW] MIN MAX
MULTIFLAM 500.1 PR
MODEL
VGD 20.503
VGD 40.065
VGD 40.080
VGD 40.100
VGD 40.125
VGD 20.503
VGD 40.065
VGD 40.080
VGD 40.100
VGD 40.125
VGD 20.503
VGD 40.065
VGD 40.080
VGD 40.100
VGD 40.125
VGD 20.503
VGD 40.065
VGD 40.080
VGD 40.100
VGD 40.125
GAS TRAIN TYPE
2"
DN65
DN80
DN100
DN125
2"
DN65
DN80
DN100
DN125
2"
DN65
DN80
DN100
DN125
2"
DN65
DN80
DN100
DN125
ร
3121384
3124111
3142088
3142205
3142206
3121384
3124111
3142088
3142205
3142206
3121384
3124111
3142088
3142205
3142206
3121384
3124111
3142088
3142205
3142206
Filter 2''
Filter DN65
Filter DN80
Filter DN100
Filter DN125
Filter 2''
Filter DN65
Filter DN80
Filter DN100
Filter DN125
Filter 2''
Filter DN65
Filter DN80
Filter DN100
Filter DN125
Filter 2''
Filter DN65
Filter DN80
Filter DN100
Filter DN125
GAS GOVERNOR AND FILTER CODE TYPE
www.ecoflam-burners.com
51
4000
3690
2700
2500
2000
1500
17000
15000
13000
10500
8500
7500
OUTPUT [kW] MIN MAX
TC
TC
TC
TC
TC
TC
-
-
-
-
-
-
BURNER BODY BLAST TUBE CODE
OPT
OPT
OPT
OPT
OPT
OPT
SILENCER
330
500
MULTIFLAM - DUOBLOCK AND ELECTRONIC BURNERS Versions from 2 to 25 MW are available on request for selected output to match main boilers and industry application.
VGD 40.100
VGD 40.125
VGD 40.150
175 210
VGD 40.080
450
VGD 40.100
VGD 40.125
150 230
VGD 40.150
125 500
VGD 40.080
420
VGD 40.100
VGD 40.125
175 230
VGD 40.150
160 500
VGD 40.065
550
VGD 40.080
VGD 40.100
165 290
VGD 40.125
115 500
VGD 40.065
410
VGD 40.080
VGD 40.100
110 210
VGD 40.125
85 500
VGD 40.065
VGD 40.080
280
140
VGD 40.100
75 500
VGD 40.125
GAS TRAIN (§) TYPE
60
PRESSURE [mbar] MIN MAX
! § VGD Siemens: default blank spring, head pressure 0...22 mbar; from MULTIFLAM 3000.1 change spring and damping (see pag. 53)
3/400/50Hz
MULTIFLAM 1800.1 PR
3/400/50Hz
MULTIFLAM 1500.1 PR
3/400/50Hz
MULTIFLAM 1200.1 PR
3/400/50Hz
MULTIFLAM 1000.1 PR
3/400/50Hz
MULTIFLAM 800.1 PR
3/400/50Hz
MULTIFLAM 700.1 PR
MODEL
Two stage progressive mechanical gas / Two stage progressive mechanical heavy oil - 50°E fuel viscosity at 50°C
DN100
DN125
DN150
DN80
DN100
DN125
DN150
DN80
DN100
DN125
DN150
DN65
DN80
DN100
DN125
DN65
DN80
DN100
DN125
DN65
DN80
DN100
DN125
Ø
Filter DN100
Filter DN125
Filter DN150
Filter DN80
Filter DN100
Filter DN125
Filter DN150
Filter DN80
Filter DN100
Filter DN125
Filter DN150
Filter DN65
Filter DN80
Filter DN100
Filter DN125
Filter DN65
Filter DN80
Filter DN100
Filter DN125
Filter DN65
Filter DN80
Filter DN100
Filter DN125
GAS GOVERNOR AND FILTER
52
www.ecoflam-burners.com
Export gas trains MAX GAS 40-250
Only Export (not EN676)
RP 25 - 1" RP 40 - 1"1/2
GT-K1-VAS125-RP25-MAXGAS170-250 GT-K1-VAS240-RP40-MAXGAS170-250
RP 15 - 1/2"
GT-B1-E6GSRP-RP15-MAXGAS40-120
RP 15 - 1/2"
RP 15 - 1/2" GT-B1-EG12L-RP15-MAXGAS40-120
Ø
RP 50 - 2"
GT-K2-VCS350-RP50-MAXGAS350-500/MULTI
GT-D1-GBLE055-RP15-MAXGAS40-120
RP 40 - 1"1/2
GT-K2-VCS240-RP40-MAXGAS350-500/MULTI
DESIGNATION
RP 25 - 1"
DESCRIPTION
Ø
DESIGNATION GT-K2-VCS125-RP25-MAXGAS350-500/MULTI
DESCRIPTION
CONFIGURATION
RP 40 - 1"1/2
VCS Kromschröder MAX GAS 350-500
RP 25 - 1"
GT-K1-VCS240-RP40-MAXGAS170-250
RP 40 - 1"1/2
GT-D2-MBDLE415-RP40-MAXGAS350-500
GT-K1-VCS125-RP25-MAXGAS170-250
RP 32 - 1"1/4
GT-D2-MBDLE412-RP32-MAXGAS350-500
VCS Kromschröder MAX GAS 170-250
RP 25 - 1"
GT-D2-MBDLE410-RP25-MAXGAS350-500
Ø
RP 20 - 3/4"
DESIGNATION
Ø
DESIGNATION
RP 40 - 1"1/2
GT-D2-MBZRDLE415-RP40-MAXGAS170-250 GT-D2-MBDLE407-RP20-MAXGAS350-500
RP 32 - 1"1/4
GT-D2-MBZRDLE412-RP32-MAXGAS170-250
RP 40 - 1"1/2
GT-D1-MBDLE415-RP40-MAXGAS170-250
RP 25 - 1"
RP 32 - 1"1/4
GT-D1-MBDLE412-RP32-MAXGAS170-250
RP 20 - 3/4"
RP 25 - 1"
GT-D1-MBDLE410-RP25-MAXGAS170-250
GT-D2-MBZRDLE410-RP25-MAXGAS170-250
RP 20 - 3/4"
GT-D1-MBDLE407-RP20-MAXGAS170-250
GT-D2-MBZRDLE407-RP20-MAXGAS170-250
RP 20 - 3/4"
GT-D1-MBDLE405-RP20-MAXGAS40-120
RP 20 - 3/4"
RP 15 - 1/2"
GT-D1-MBDLE403-RP15-MAXGAS40-120
GT-D2-MBZRDLE405-RP20-MAXGAS40-120
RP 20 - 3/4"
GT-D1-MBC120DLE-RP20-MAXGAS40-120
Ø
RP 15 - 1/2"
GT-D1-MBC65DLE-RP15-MAXGAS40-120
DESIGNATION
Ø
DESIGNATION
DESCRIPTION
MB-DLE MultiBloc Dungs MAX GAS 350-500
DESCRIPTION
MB-ZRDLE MultiBloc Dungs MAX GAS 40-250
DESCRIPTION
MB-DLE MultiBloc Dungs MAX GAS 40-250
DESCRIPTION
Double solenoid valves VCS Kromschröder and min pressure switch + ACS gas governor & filter
Export EN676 + FGDR
CONFIGURATION
WARNING: EN676 compulsory kit and accessories in order to comply to the safety regulations. Additional accessories and kits shall be installed by the installer in accordance to the local safety regulations and codes of practise.
MultiBloc Dungs: compact double solenoid valve with integrated filter, regulator and min pressure switch.
EN676
CONFIGURATION
GAS TRAIN: MAX GAS CODE
3142816
3142815
3141887
3141888
3142027
CODE
3142376
3142375
3142374
CODE
3142251
3141906
CODE
3142296
3142295
3142665
3142392
CODE
3123879
3141901
3123962
3123961
3123960
CODE
3123969
3141899
3123947
3123525
3123560
3123944
3141886
3141885
www.ecoflam-burners.com
53
WARNING: from BLU 1700.1 - MULTICALOR 170.1 MULTIFLAM 200.1, in order to fit the gas train, the corresponding connection pipe must be ordered (GTCP size and fitting depend on the burner and the gas train selected)
GAS TRAIN CONNECTION PIPE
WARNING: from BLU 3000.1 - MULTICALOR 300.1 MULTIFLAM 300.1 change spring and damping
Export / EN676 + FGDR Double gas valves with actuators and regulator VGD Siemens and min pressure switch + ACS gas filter. Default blank spring: head pressure 0...22 mbar
VGD SIEMENS
Export / EN676 + FGDR Double solenoid valves VCS Kromschröder and min pressure switch + ACS gas governor & filter
VCS KROMSCHRÖDER
EN676 MultiBloc Dungs: compact double solenoid valve with integrated filter, regulator and min pressure switch.
MB-DLE MULTIBLOC DUNGS
SPRING
DAMPING THROTTLE
Gas trains include ACTUATORS
DESCRIPTION GTCP RP50-DN65 platform 260 GTCP RP50 platform 280 GTCP RP50 platform 280/320/380 GTCP RP50 BLU 1500 with MB415-420 GTCP RP50 adaptor for MULTIFLAM GTCP DN65 platform 260/280/320 GTCP DN80 platform 260/280/320 GTCP DN65 platform 380 GTCP DN80 platform 380 GTCP reducer from DN80 to DN65 for MULTIFLAM GTCP reducer from DN100 to DN80 platform 320/380 GTCP reducer from DN125 to DN80 platform 320/380 GTCP DN125 platform 380 GTCP DN65 platform 630 GTCP DN80 platform 630/710 GTCP DN100 platform 630/710 GTCP DN125 platform 630/710 Both codes necessary for gas train DN125 GTCP reducer from DN125 to DN100
DESIGNATION GT-D2-MBDLE407-RP20-BLU/MULTI GT-D2-MBDLE410-RP25-BLU/MULTI GT-D2-MBDLE412-RP32-BLU/MULTI GT-D2-MBDLE415-RP40-BLU/MULTI GT-D2-MBDLE420-RP50-BLU/MULTI DESIGNATION GT-K2-VCS125-RP25-BLU/MULTI GT-K2-VCS240-RP40-BLU/MULTI GT-K2-VCS350-RP50-BLU/MULTI DESIGNATION GT-S2-VGD20-RP50-BLU/MULTI GT-S2-VGD40-DN65-BLU/MULTI GT-S2-VGD40-DN80-BLU/MULTI GT-S2-VGD40-DN100-BLU/MULTI GT-S2-VGD40-DN100+VDK-BLU/MULTI GT-S2-VGD40-DN125-BLU/MULTI GT-S2-VGD40-DN125+VDK-BLU/MULTI Yellow setpoint spring for SKP25... Damping throttle for SKP25...
GAS TRAIN AND GTCP: BLU - MULTICALOR - MULTIFLAM
DESIGNATION GTCP-RP50-DN65-260 GTCP-RP50-280 GTCP-RP50-320/380 GTCP-RP50-BLU1500-MB415-420 GTCP-RP50-ADAPTOR-MULTIFLAM GTCP-DN65-260/280/320 GTCP-DN80-260/280/320 GTCP-DN65-380 GTCP-DN80-380 GTCP-REDUCERDN80TODN65 GTCP-REDUCERDN100TODN80 GTCP-REDUCERDN125TODN80 GTCP-DN125-380 GTCP-DN65-630 GTCP-DN80-630/710 GTCP-DN100-630/710 GTCP-DN125-630/710 GTCP-REDUCERDN125TODN100
Head pressure: 15...120 mbar
Ø RP 20 - 3/4" RP 25 - 1" RP 32 - 1"1/4 RP 40 - 1"1/2 RP 50 - 2" Ø RP 25 - 1" RP 40 - 1"1/2 RP 50 - 2" Ø RP 50 - 2" DN 65 - 2" 1/2 DN 80 - 3" DN 100 - 4" DN 100 - 4" + VDK DN 125 - 5" DN 125 - 5" + VDK
CODE 3141842 3142074 3142075 3142076 3143080 3142197 3142069 3142071 3142070 3142935 3142073 3143105 3142198 3142423 3142424 3142422 3142422 3142425
CODE 3141843 3142022 3141845 3141846 3141847 CODE 3142024 3142025 3141862 CODE 3123860 3124110 3142026 3141869 3141871 3142666 3141872 3142204 3142207
54
www.ecoflam-burners.com
500 mbar 500 mbar 500 mbar 500 mbar 500 mbar 500 mbar 1 bar 1 bar 1 bar 1 bar 1 bar
RP 15 - 1/2" *
RP 20 - 3/4" *
RP 25 - 1" *
RP 32 - 1"1/4 *
RP 40 - 1"1/2 *
RP 50 - 2" *
FS1B RP 50 - 2"
FS1B DN 65 - 2"1/2
FS1B DN 80 - 3"
FS1B DN 100 - 4"
FS1B DN 125 - 5"
SPRING for GAS GOVERNOR and FILTER FGDR
GAS PRESSURE RANGE 5÷15 mbar 10÷30 mbar 25÷80 mbar 70÷160 mbar 150÷280 mbar 270÷350 mbar 5÷15 mbar 10÷25 mbar 20÷70 mbar 65÷130 mbar 120÷250 mbar 240÷350 mbar 5÷15 mbar 10÷35 mbar 30÷80 mbar 70÷220 mbar 210÷350 mbar
DESCRIPTION
Green spring FGDR 15-20-25
Neutral spring FGDR 15-20-25
Violet spring FGDR 15-20-25
Brown spring FGDR 15-20-25
Blue spring FGDR 15-20-25
White spring FGDR 15-20-25
Green spring FGDR 32-40
Neutral spring FGDR 32-40
Violet spring FGDR 32-40
Brown spring FGDR 32-40
White spring FGDR 32-40
Black spring FGDR 32-40
Green spring FGDR 50
Neutral spring FGDR 50
Violet spring FGDR 50
Brown spring FGDR 50
Blue spring FGDR 50
* Default spring is neutral for outlet pressure range 10-30 mbar
GAS GOVERNOR and FILTER FGDR
MAX GAS PRESSURE
DESCRIPTION
KIT AND ACCESSORIES FOR GAS
3142563
3142562
3142561
3142560
3142559
3142558
3142557
3142556
3142555
3142554
3142553
3142552
3142551
3142550
3142549
3142548
3142547
CODE
on request
on request
3142538
3141983
3142051
3142524
3142523
3142522
3142521
3142520
3142519
CODE
MANUAL VALVE
ANTIVIBRATION COUPLING
GAS FILTER
CODE 3142000 3142254 3121430 3142253 3142101 3142102 3142062 3143730 3141997 3141998
RP 15 - 1/2" RP 20 - 3/4" RP 25 - 1" RP 32 - 1"1/4 RP 40 - 1"1/2 RP 50 - 2" DN 65 - 2"1/2 DN 80 - 3" DN 100 - 4" DN 125 - 5"
3122321 3122322 3122323 3122324 3122325 3122326 3142060 3122328 3122329 3142061
RP 15 - 1/2" RP 20 - 3/4" RP 25 - 1" RP 32 - 1"1/4 RP 40 - 1"1/2 RP 50 - 2" DN 65 - 2"1/2 DN 80 - 3" DN 100 - 4" DN 125 - 5"
DESCRIPTION
CODE
RP 15 - 1/2" RP 20 - 3/4" RP 25 - 1" RP 40 - 1"1/2 RP 50 - 2" DN 65 - 2"1/2 DN 80 - 3" DN 100 - 4" DN 125 - 5"
DESCRIPTION
CODE 3141957 3142045 3142046 3141954 3121384 3124111 3142088 3142205 3142206
DESCRIPTION
www.ecoflam-burners.com
55
KIT LPG / KIT GN
MANOMETER + PUSH BUTTON
MAXIMUM GAS PRESSURE SWITCH
TIGHTNESS CONTROL
KITTC-VPS504-VCS KITTC-LPGVPS504-VCS KITTC-VPS504-MB-VGDDN65-80 KITTC-LPGVPS504-MB-VGDDN65-80 KITTC-VPS504-VGD20503 KITTC-LPGVPS504-VGD20503 KITTC-VDK200 KITTC-LDU11
Kit tightness control VPS504 for VCS gas valve
Kit tightness control VPS504 LPG for VCS gas valve
Kit tightness control VPS504 for MB and VGD65-80 valve
Kit tightness control VPS504 LPG for MB and VGD65-80 valve
Kit tightness control VPS504 for VGD20503 valve
Kit tightness control VPS504 LPG for VGD20503 valve
Kit tightness control VDK for VGD100-125
Kit tightness control LDU
100÷5800 kW 7000÷25000 kW GAS PRESSURE 0…60 mbar 1/2" 0…250 mbar 1/4" 0…1000 mbar 1/4" Diameter 1/4" Diameter 1/2" BURNER MAX GAS 40-120 MAX GAS 40-120 MAX GAS 170-250 MAX GAS 170-250 MAX GAS 350-500 BLU 500.1 BLU 700.1 BLU 1000.1-1200.1-1500.1 BLU 1700.1-2000.1
KITPRES50
KITPRES150
DESCRIPTION
Gas manometer
Gas manometer
Gas manometer
Push button 1/4"
Push button 1/2"
DESIGNATION
KITLPG-MAXGAS40-120
KITADAPTOR-MAXGAS40-120
KITLPG-MAXGAS170-250
KITADAPTOR-MAXGAS170-250
KITLPG-MAXGAS350-500
KITLPG-BLU500.1
KITLPG-BLU700.1
KITLPG-BLU1000.1-1500.1
KITLPG-BLU1700.1-2000.1
Other model kit on request
OUTPUT RANGE
DESIGNATION
Kit adaptor for kit VPS pilot gas train
DESIGNATION
DESCRIPTION
KIT AND ACCESSORIES FOR GAS
30÷150 mbar
2,5÷50 mbar
GAS PRESSURE
CODE
3142667
3124489
3124488
3124487
3142431
3122300
3122302
3122299
3122301
CODE
3142057
3142058
3142054
3142055
3142056
CODE
3142033
3141921
CODE
3142754
3142314
3141922
3142688
3122305
3142190
3122303
3142238
3141929
56
www.ecoflam-burners.com
KIT-AUTOMATICFUELSWITCH-MULTI
DESIGNATION Dual fuel burners: MULTICALOR and MULTIFLAM
DESCRIPTION
Swirls for blast tube that can reduce flame lenght up to 10-50% depending on fuel, backpressure and shape of combustion chamber. The system is available for different fuel burner blast tubes
DESCRIPTION
“OIL RING” can be design and delivered assembled on skid or offered as single component
DESCRIPTION
Separate service tanks and pump units
DESCRIPTION
From OILFLAM 300.1 pre-heater can be supplied separately with extra cost
DESCRIPTION
BLU - MULTICALOR (PR versions)
KITWP-BLU/MULTICALOR-PR/MD
MAIOR 45 - 300.1
KITWP-MAIOR35-300.1PAB BLU 500.1 - 2000.1 (PAB versions)
DESCRIPTION
DESIGNATION
KITWP-BLU500.1-2000.1PAB
MAXFLAM range OILFLAM range
DESCRIPTION
DESIGNATION
KITOIL250KG-MAGNETIC+SELFCLEANING-FILTER
MAX P 12-15 AB HS
KITBIODIESEL-PUMP-AT2/AT3
KITOIL50KG-MAGNETIC+SELFCLEANING-FILTER
MAX 1...30 and MAX P 25 AB HS
KITBIODIESEL-PUMP-AS47
DIAGNOSTIC TOOL
CODE
3142931 3833018
PC interface for BCU
CODE
3141932
3142034
3142037
CODE
3141965
3142092
CODE
3124103
3141917
CODE
3142021
E-BCU Diagnostic tool for 1 stage BCU
DESCRIPTION
DIAGNOSTIC TOOL FOR THERMOWATT CONTROL
SWIRL SYSTEM
HEAVY OIL HEATING AND PUMPING UNIT
LIGHT OIL PUMPING UNIT
SEPARATE PRE-HEATER UNIT
KIT WIELAND PLUGS
MAGNETIC + SELFCLEANING FILTER
KIT BIODIESEL
DESCRIPTION
DESIGNATION
Standard version running on manual fuel selection mode and with the automatic changeover the system change fuel triggered by a gas pressure switch or by a timer
KIT FOR AUTOMATIC FUEL SWITCH GAS/OIL
KIT AND ACCESSORIES FOR OIL
www.ecoflam-burners.com
57
LIGHT OIL
Option available starting from platform 260
Separate ventilator silencer / Sound proof platform on request
DUOBLOCK
MAIOR 700.1 - 1200.1
DESCRIPTION
3122317
CODE 3141911 3122298 3141913 3141914 3142276 3142668
KITSIL-260 KITSIL-280 KITSIL-320 KITSIL-380 KITSIL-630 KITSIL-710
OILFLAM 1500.1 - 1800.1
OILFLAM 700.1 - 1200.1
OILFLAM 500.1 - 600.1
OILFLAM 300.1 - 400.1
OILFLAM 170.1 - 200.1
OILFLAM 50.1 - 120.1
MULTICALOR 1500.1 - 1800.1
MULTICALOR 700.1 - 1200.1
MULTICALOR 500.1 - 600.1
MULTICALOR 300.1 - 400.1
MULTICALOR 170.1 - 200.1
MULTICALOR 45 - 140
DUAL FUEL (GAS/LIGHT OIL)
PROBE-HOTAIR-LIQUID450C
Hot air or liquid probe up to 0÷450° С
HEAVY OIL
PROBE-STEAM16BAR PROBE-STEAM40BAR
Steam probe 0÷16 bar Steam probe 0÷40 bar
PROBE-STEAM4BAR PROBE-STEAM10BAR
Steam probe 0÷4 bar Steam probe 0÷10 bar
3124100
PROBE-STEAM2BAR
Steam probe 0÷2 bar
MULTIFLAM 1500.1 - 1800.1
MULTIFLAM 700.1 - 1200.1
MULTIFLAM 500.1 - 600.1
MULTIFLAM 300.1 - 400.1
MULTIFLAM 170.1 - 200.1
MULTIFLAM 50.1 - 120.1
DUAL FUEL (GAS/HEAVY OIL)
3122314
3122320
3122319
3122318
3122316
DESIGNATION PROBE-WATER130C
DESCRIPTION
CODE
CODE 3143713
DESIGNATION KITMD-RWF50
Water probe up to 0÷130° С
Kit for progressive version
PLATFORM
MAIOR 1500.1 - 1800.1
BLU 7000.1 - 12000.1
BLU 15000.1 - 18000.1
KITSIL-630
MAIOR 500.1 - 600.1
MAIOR 300.1 - 400.1
MAIOR 150.1 - 200.1
MAIOR 45 - 120
KITSIL-710
BLU 3000.1 - 4000.1
BLU 5000.1 - 6000.1
KITSIL-320
BLU 1500.1 - 2000.1
KITSIL-280
KITSIL-380
GAS
BLU 700.1 - 1200.1
PLATFORM
KITSIL-260
SILENCER
MATCHING PROBE FOR FULL MD VERSION
MODULATING PID CONTROLLER
LOAD CONTROLLER AND PROBES
BURNER SELECTION FORM SECTION 1 - GENERAL INFORMATION CUSTOMER - COUNTRY REFERENCE SALES PERSON REQUEST DATE INSTALLATION LOCATION SEGMENT
heating heating OEM
bakery dryers
projects other industry
SECTION 2 - BOILER INFORMATION
BOILER TYPE
three pass boiler
Boiler brand
reverse flame boiler
Boiler model
water tube boiler
Boiler manuf. year
diathermic boiler incinerator APPLICATION TYPE
dryer / hot air generator oven steam (saturated)
Steam capacity
[TPH]
Required steam pressure
bar
hot water
Steam temperature
[°C]
salt / oil
Medium temperature
[°C]
Medium inlet temperature
[°C]
steam (superheated) HEAT TRANSFER MEDIUM
STEAM
OTHER
others
POWER REQUIREMENT
BOILER LOCATION
Boiler Output
[kW]
Boiler Input
[kW]
Boiler efficiency
[%]
Burner power
[kW]
Backpressure
[mbar]
1 kW = 860 kcal/h
outdoor indoor
HEIGHT ABOVE SEA LEVEL [m]
DIMENSIONS [mm] Inner diameter
Furnace position FURNACE CHAMBER DATA
horizontal
Length
top-down
Return chamber length
bottom-up
Length Height
ELECTRICAL SUPPLY DATA
Width
min [mm]
Required blast tube Lenght
max [mm]
Voltage single phase
110 V
220 V
230 V
240 V
Voltage three phase
220 V
380 V
400 V
415 V
Frequency
50 Hz
60 Hz
Required IP factor
IP40
IP54
440 V
460 V
480 V
other:
SECTION 3 - FUEL INFORMATION LIGHT OIL - HEAVY OIL
GAS / LPG
Type: …………………………...............
58
BIOGAS-TOWNGAS (Max H2S<0,1%)
Type: ………………………..............
Type: ………………………………………..................
Lower calorific value
[kcal/kg]
Lower calorific value
[kcal/m3]
Lower calorific value
[kcal/m3]
Viscosity at 50°C
[°E]
Supply pressure
[mbar]
Supply pressure
[mbar]
Required flowrate
[kg/h]
Required flowrate
[m3/h]
Required flowrate
[m3/h]
www.ecoflam-burners.com
SECTION 4 - BURNER BURNER TYPE
BURNER POWER
Duoblock
Monoblock
[°C] (Max 200°C) [mbar] [m3/h] [mbar]
refer to the field "burner power" in the section "power requirement" mechanical: electronic:
NOMINAL TURNDOWN RATIO EMISSIONS LEVEL
Combustion air temperature Heat exchanger pressure losses flowrate: Current fan (if existing): pressure:
NOx: CO:
Gas:
1:3 1:6
electronic with inverter: electronic with inverter:
<120 mg/kWh
<80 mg/kWh
Class 2
Class 3
EN676
0...100 mg/kWh
FUEL SUPPLY
single fuel two fuels three fuels
CONTROL TYPE
1 stage 2 stages 2 stage progressive mechanical modulating mechanical with PID modulating electronic
OPTIONS FOR ELECTRONIC VERSION
inverter (modulating electronic only) O2 trim (modulating electronic only) CO trim (modulating electronic only)
ELECTRICAL CONFIGURATION
standard electrical panel loosen form with derivative panel separate switch cabinet
Light Oil: EN267
1:8 1:10 <250 mg/kWh
<185 mg/kWh
Class 1
Class 2
0...110 mg/kWh
FUEL 1: FUEL 2: FUEL 3:
<120 mg/kWh Class 3 0...60 mg/kWh
Automatic fuel changeover
Other requirements: specify
SECTION 5 - GAS TRAIN CONFIGURATION Gas governor and filter Gas train type
Dungs MultiBloc Siemens VGD Kromschröder VCS Honeywell
FGDR Max 500 mbar FS1B Max 1 bar ST4B Max 4 bar Filter Max 1 bar
Tightness control VPS VDK LDU Electronic
Maximum pressure switch KITPRES50 up to 6 MW KITPRES150 up to 25 MW
Other requirements: specify
NOTES - ADDITIONAL INFORMATION
www.ecoflam-burners.com
59
HEAD OFFICE: Via Roma, 64 31023 Resana (TV)
REGISTERED OFFICE: Viale A. Merloni, 45 60044 Fabriano (AN)
Tel.: +39 0423 719500 Fax: +39 0423 719580 Web: www.ecoflam-burners.com Email: export@ecoflam-burners.com Company subject to the direction and coordination of Ariston Thermo SpA. - Via A. Merloni, 45 - 60044 Fabriano (AN) - CF 01026940427
Version 1.5 - 15/07/2014 ECOFLAM Bruciatori S.p.A. reserves the right to make any adjustments, without prior notice, which is considered necessary or useful to its products, without aďŹ&#x20AC;ecting their main features.