IS II Active

Page 1


IS-II active Product Catalog

Contents S.L.A. Surface of IS-II active

4

Features of IS-II active

6

IS-II active Line up

8

Prosthetic Flow Chart

10

IS Full Kit

12

IS Full Kit Components

13

IS-II active Drilling Sequence

15


S.L.A. Surface of IS-II active S.L.A. (Sandblasting with Large grit and Acid etching)

IS-II active Surface

Macropore & Micropore

Macropores and micropores formed by S.L.A. surface treatment increase B.I.C.(Bone-Implant Contact) and allow better blood flow on the implant surface.

S.L.A. Surface

S.L.A.

S.L.A. surface is formed by undergoing the process of sandblasting with smaller than 50 ㎛ HA (Hydroxy Apatite) particles to roughen the machined surface and to form many macropores. After sandblastingand acid etching is done to increase B.I.C. and promote cell’s activity. With this process, the typical treatment period can be shortened and the patients will be more satisfied with the result.

S.L.A. Surface Treatment Process Miling

Sand Blasting

Acid Etching HA Powder

Machined

4

R.B.M.

S.L.A.


S.L.A. Surface of IS-II active Roughness of IS-II active Regular roughness / R.A. 2.0 (Roughness Average)

1,960 RA(㎛)

2,0 20 RA(㎛)

Other company’s S.L.A. Surface

Neobiotech’s S.L.A. Surface

Cell adhesion capability of S.L.A. Surface It is observed that S.L.A. surface has the capability of attaching more cells on the titanium surface than the machined or R.B.M. surfaces.

Machined

R.B.M.

S.L.A.

Measured distance of newly formed bone Measured distance of newly formed bone is approved to be longer in S.L.A. surface compared to R.B.M. surface.

R.B.M.

Distance of newly formed bone Left : 1.976mm/ Right : 2.35mm

F : Fixture / BM : Bone Marrow / NB : New Bone

S.L.A.

Distance of newly formed bone Left : 2.460 mm Right : 2.41mm

F : Fixture / BM : Bone Marrow / NB : New Bone

5


Features of IS-II active Based on the accumulated clinical cases and studies over 10 years, IS-II active has been continuously developed for the improvement. IS-II active has an internal submerged type design with S.L.A. surface that allows faster and stronger osseointegration.

BioSeal(0.5mm) BioSeal is a curved S shape placed at the top of the fixture broadens the surface and increases the attachment of the soft tissue, therefore minimizes the bone loss.

Straight–Taper Body helps implant to be drilled and inserted smoothly and also self-compaction is easily achieved in the soft bone.

Coronal Macro Thread

(Thread pitch 0 .8mm)

Coronal Macro thread gains better primary stability at the cortical bone that helps to achieve better fixation in immediate placement.

Magic Thread Magic Thread helps to achieve strong and stable initial fixation and also the inverted triangular threads enables to endure vertical and lateral forces.

Apex Apex is powerful in drilling and due to this selfcompactable and tapered apex design, initial fixation is easily achieved. It works great in both immediate placement and immediate loading.

S.L.A. Surface S.L.A. Surface has no impurities on the implant surface (No residual acid or cell toxicity is observed in the material examination). Also it has an appropriate rough average that can have the excellent osteoconductivity.

BioSeal BioSeal has a curved S shape with the application of 0 .5mm micro grooves on the machined surface. This design is invented to minimize the bone loss by maximizing soft tissue sealing.

Coronal Macro Thread Coronal macro threads helps to achieve excellent primary stability at the cortical bone and initial fixation at the apex is excellent, therefore IS-II active works great in both immediate placement and immediate loading.

Magic Thread Magic Thread with the inverted triangular shaped powerful deep thread helps to achieve strong and stable initial fixation and also this special design allows to endure vertical and lateral forces effectively.

6


Features of IS-II active Connection of IS-II active Conical Sealing & Internal Hex Structure 22

22 0 .4mm

- Group A : IS-II active all Narrow, Regular, Wide 7.3mm Fixture - Group B : IS-II active Regular, Wide 8.5, 10 .0 , 11.5, 13.0 mm Fixture

Group A (Gray)

Group B (White)

IS-II active Fixture is compatible with all abutments of IS system. * In order to increase the strength of fixture body, Internal hex of Group A is designed 0 .4mm higher than Group B.

Fixture Placement Procedure

Take the fixture out from the box

Remove the package surrounding the fixture

Connect the fixture to the driver

Take the fixture out from the holder

Take of the back seal

Take out the holder carefully

7


IS-II active Fixture Line Up Narrow Ø 3.5 Ø 3.5

Actual Size

Length

Length (mm)

Product Code

8.5

BIS350 8A

10 .0

BIS3510 A

11.5

BIS3511A

13.0

BIS3513A

Length (mm)

Product Code

7.3

BIS40 0 7A

8.5

BIS40 0 8A

10 .0

BIS40 10 A

11.5

BIS40 11A

13.0

BIS40 13A

Length (mm)

Product Code

7.3

BIS450 7A

8.5

BIS450 8A

10 .0

BIS4510 A

11.5

BIS4511A

13.0

BIS4513A

Length (mm)

Product Code

7.3

BIS50 0 7A

8.5

BIS50 0 8A

10 .0

BIS50 10 A

11.5

BIS50 11A

13.0

BIS50 13A

Ø 3.5

Regular Ø 4.0 Ø 3.7

Actual Size

Length

Ø 4.0

Regular Ø 4.5 Ø 3.9

Actual Size

Length

Ø 4.5

Wide Ø 5.0 Ø 4.4

Actual Size

Length

Ø 5.0

8


IS-II active Fixture Line Up S-wide Platform

Diameter (Ø)

Length

5.5

Platform (Ø)

4.4

Diameter

6.0

7.0

4.9

5.8

Length (mm)

Code

7.3

BIS550 7A

8.5

BIS550 8A

10 .0

BIS5510 A

11.5

BIS5511A

13.0

BIS5513A

7.3

BIS60 0 7A*

8.5

BIS60 0 8A*

10 .0

BIS60 10 A*

11.5

BIS60 11A*

13.0

BIS60 13A*

7.3

BIS70 0 7A*

8.5

BIS70 0 8A*

10 .0

BIS70 10 A*

11.5

BIS70 11A*

13.0

BIS70 13A*

Length (mm)

Product Code

5.0

BIS50 0 5A

6.0

BIS50 0 6A

5.0

BIS550 5A*

6.0

BIS550 6A*

Short Platform

Length

7.3mm

Diameter (Ø)

Platform (Ø)

5.0

4.4

5.5

4.5

Diameter

S-wide Kit

* S-Wide Kit is necessary to place S-wide Fixture and Ø 5.5 Short Fixture

9


Prosthetic Flow Chart Solid Abutment

Plastic coping

Lab analog

Impression cap

1.2 Hex driver

Healing abutment

Solid abutment

Protective cap

Cover screw

1.2 Hex driver

IS-II active

10


Prosthetic Flow Chart Cement & Screw Abutment

Straight

SCRP multi

Hex

R

Gold

SCRP multi

Hex

Non-hex Abutment positioner

Angled

R

Non-hex

CCM

Plastic coping

Hex

Non-hex

SCRP multi

Hex

Shapable

R

Non-hex

Plastic

Lab analog Hex

SCRP multi

R

Impression cap

SCRP multi

Pick up 1.2 Hex driver

Non-hex

Transfer

Abutment positioner

Healing abutment

Non-hex

Lab analog

R

Hex

Hex

Non-hex

Cover screw

Impression coping positioner

1.2 Hex driver

IS-II active

11


IS-II active Drilling Sequence IS-II active Fixture Ø3.5 X 10 mm (D1/D2 bone) Point Lindemann Ø2.3

Initial Drill Ø2.2

Twist Drill Ø2.9

Profile Tap Ø3.5

* Drilling Speed & Torque Point Lindemann, Initial Drill, Twist Drill : 1,20 0 R.P.M / 30 ~ 45 Ncm Profile Tap : 50 R.P.M / 50 Ncm

D1 10 mm

D2

Tip Length 1 mm

※ If the bone density is low and soft, drilling 10 mm with Ø 2.3 Lindemann drill and then place the fixture.

IS-II active Fixture Ø4.0 X 10 mm (D1/D2 bone) Point Lindemann Ø2.3

Initial Drill Ø2.2

Twist Drill Ø2.9

Twist Drill Ø3.4

Profile Tap Ø4.0

D1 10 mm

D2

Tip Length 1 mm

※ If the bone density is low and soft, drill 10 mm up to Ø 2.9 Twist drill and then place the fixture.

IS-II active Fixture Ø4.5 X 10 mm (D1/D2 bone) Point Lindemann Ø2.3

Initial Drill Ø2.2

Twist Drill Ø2.9

Twist Drill Ø3.4

Twist Drill Ø3.9

Profile Tap Ø4.5

D1 10 mm

D2

Tip Length 1 mm

※ If the bone density is low and soft, drill 10 mm up to Ø 3.4 Twist drill and then place the fixture.

IS-II active Fixture Ø5.0 X 10 mm (D1/D2 bone) Point Lindemann Ø2.3

Initial Drill Ø2.2

Twist Drill Ø2.9

Twist Drill Ø3.4

Twist Drill Ø3.9

Twist Drill Ø4.4

Profile Tap Ø5.0

D1 10 mm

D2

Tip Length 1 mm

※ If the bone density is low and soft, drill 10 mm up to Ø 3.9 Twist drill and then place the fixture.

IS-II active Fixture Ø5.5 X 10 mm (D1/D2 bone) Point Lindemann Ø2.3

Initial Drill Ø2.2

Twist Drill Ø2.9

Twist Drill Ø3.4

Twist Drill Ø3.9

Twist Drill Twist Drill Ø4.4 Ø4.9

Profile Tap Ø5.5

D1 10 mm Tip Length 1 mm

D2

※ If the bone density is low and soft, drill 10 mm up to Ø 4.4 Twist drill and then place the fixture.

15


STOP DRILL KIT

Linderman Drill Diameter

Product Name

⌀2.3

LDS23C

Stop Drill Diameter ⌀

Length

(mm)

⌀2.2

⌀3.0

⌀3.5

⌀4.0

⌀4.5

⌀5.0

7.3

TSD2207S9

TSD3007S9

TSD3507S9

TSD4007S9

TSD4507S9

TSD5007S9

8.5

TSD2208S9

TSD3008S9

TSD3508S9

TSD4008S9

TSD4508S9

TSD5008S9

10.0

TSD2210S9

TSD3010S9

TSD3510S9

TSD4010S9

TSD4510S9

TSD5010S9

11.5

TSD2211S9

TSD3011S9

TSD3511S9

TSD4011S9

TSD4511S9

TSD5011S9

13.0

TSD2213S7

TSD3013S7

TSD3513S7

TSD4013S7

TSD4513S7

TSD5013S7

7.3mm

8.5mm

10.0mm

11.5mm

13.0mm


STOP DRILL KIT Cortical Drill & Tap (0.8 , 0.9 Pitch) Cortical Drill

Diameter ⌀

Cortical Tap (IS II active)

Cortical Tap (IS III active)

FØ3.5

CD38

CT38S08

CT38S09

FØ4.0

CD43

CT43S08

CT43S09

FØ4.5

CD45

CT45S08

CT45S09

FØ5.0

CD50

CT50S08

CT50S09

FØ5.5

CD55

CT55S08

CT55S09

Fixture Driver

Connector

Length

Product Name

Length

Product Name

Ratchet(Short)

ISFD10R

Long

RC15

Ratchet(Long)

ISFD15R

Contra Angle(Short)

ISFD05C

Product Name

CAA00

Contra Angle(Long)

ISFD05CL

Direction Pin

Parallel Pin

Diameter

Product Name

Length

Product Name

⌀3.5

DPIS35C

7.0mm

PP07F

⌀4.5

DPIS45C

8.5mm

PP08F

10.0mm

PP10F

Drill Extension

Hex Driver Length(mm)

Product Name

15mm

HD1215S

Torque Ratchet Product Name

Product Name

DE01

Driver Holder & Depth Gauge TW60

Product Name

DHDG


IS CORE KIT IS Fixture Driver

Point Drill

Surgical Drill

Cortical Tap

Hex Driver

Ratchet

Connector

Torque Ratchet

Drill Stopper

Drill Extension

Product Name

Parallel Pin

NEOCKIT

Point Drill ⌀ 2.3

Drilling Sequence (IS-III active)

Surgical Drill ⌀ 2.2

Surgical Drill ⌀ 3.0

Surgical Drill Cortical Tap ⌀ 4.0 ⌀ 4.0

D1 D2

10mm Drill Tip 1.2mm

Drill Tip

1.2mm

bone or in condition of getting fixation at implant apex, Ø3.0 surgical drill is the final drill *※ InInSoft(D4) Soft(D4) bone or in condition of getting fixation at implant apex, ⌀3.0 surgical drill is

Point Drill ⌀ 2.3

Surgical Drill ⌀ 2.2

Surgical Drill ⌀ 3.0

Surgical Drill ⌀ 4.0

Option

Drilling Sequence (IS-II active) Drill Tip

1.2mm

* In Soft(D4) bone or in condition of getting fixation at implant apex, ⌀3.0 surgical drill is


IS CORE KIT Guide Point Drill

Surgical Drill

Diameter

Product Name

Diameter

Product Name

⌀2.3

PD13

⌀2.2

TSD22CL

⌀3.0 (3.5F)

TSD30CL

⌀3.5 (4.0F)

TSD35CL

⌀4.0 (4.5F)

TSD40CL

⌀4.5 (5.0F)

TSD45CL

Cortical Tap

Drill Stopper

Diameter

Product Name

⌀3.5

CTS38S09

⌀4.0

CTS43S09

⌀4.5

CTS45S09

Length(mm)

⌀5.0

CTS50S09

Product Name

IS Fixture Driver Product Name

ISFD05C

DE01

Length(mm)

Product Name

8.5

PP08F

10.0

PP10F

Product Name

RC15

Torque Ratchet HD1215S

Product Name

10.0

11.5

13.0

DS070C DS085C DS100C DS115C DS130C

Ratchet Connector

Hex Driver Product Name

8.5

Parallel Pin

Drill Extension Product Name

7.3

TW60


20 12.0 9.20 Ver.1

Neobiotech Co., Ltd. E-Space #10 10 , 212-26, Guro-dong, Guro-gu, Seoul, Koea 152-789 Tel : +82-2-582-2885 Fax : +82-2- 864-2894 Email : info@neobiotech.co.kr


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.