14. Cromatografía
GENERAL CATALOGUE 2010/11
Familias de productos
Viales
1169
Ampollas, Septums, Tapones 1169
Jeringas
1178
Jeringas de microlitros 1178
Preparación de muestras
1184
SPE 1184
Columnas para cromatografía
1212
HPLC (alta resolución) 1212 + Instantáneo (Flash) 1239 + Almacenamiento/Manipulación de disolventes 1240 + GC (cromatografía de gas) 1253 + GC (cromatografía de gas) 1268
Cromatografía de capa fina Placas de microvaloración 1272 + Cámaras 1282 + Jeringas 1283 + Detección 1285 + Accesorios 1288
1168
1272
14. Cromatografía
GENERAL CATALOGUE 2010/11
Viales/Ampollas, Septums, Tapones 1 2 3 4 General informations - vials and caps
1
Materials
MACHEREY-NAGEL
According to the high requirements of chemical analyses, especially with regard to reproducibility combined with high detection sensivity, the container material for the respective samples is of great importance. In general, for this purpose vials made from glass are used. The hydrolytic resistance of the glass can be taken as a measure for its chemical inertness. Determination of the hydrolytic resistance and the resulting classification of a glass grade are governed by the German and international industrial standard DIN 12111/ISO 719. Glass grades are classified in hydrolytic classes . We supply vials from the following classes:
2
1st hydrolytic class Glass grades made from borosilicate, such as Duranfi , Pyrexfi , Fiolaxfi and others belong to this group. Glass of this class, which is often called neutral glass, has a very good chemical resistiance towards acid and neutral solutions. The relatively low alkali content permits good values for the resistance towards alkaline solutions, too. If nothing else is stated, the vials of our programm are made from glass of the 1st hydrolytic class (manufactured in accordance with Eu.Ph. VI Ed., U.S.P. XXV Ed., DAB-10, Ph. Jap. 13). 3rd hydrolytic class, AR glass Glass of this class, also called soft glass or lime soda glass, has a mediumhydrolytic resistance. For longtime storage of aqueous and especially alkaline-aqueous samples (for example to use them repeatedly) it is not recommended. Nevertheless, it can be used for many analytical applications.
3
We supply the following types of sample bottles: vials with crimp top and corresponding caps screw thread vials and srew caps sealing disks for individual combinations of cap and seal Except for a few frequently used combi packs, vials and caps can be ordered separately, thus allowing a wide range of possible combinations.
4
Advantages of the DIN crimp top: Crimp top vials are available with 3 differnt rim heights: 3 mm, DIN crimp top with 3.6 mm and 4mm. When using only one crimper, tedious adjustments for the different heights are necessary. The standardized DIN crimp top avoids this problem. The rim height in accordance with DIN 58366 should be 3.6 ±0.2 mm. We supply vials with DIN crimp top for volumes above 5 ml. Except where explicitly mentioned, caps with sealing disks are supplied assembled, i. e. ready-to-use. Seals below the caps are shown for illustration purposes only, and they are pictured upside down.
Physical properties of glass grades Parameter 1st hydrolytic class density: 2.64 thermal coefficient of linear expansion (K-1): 60 * 10-7 quenching stability (Δ T in K) in accordance with DIN 52321: 60 internal pressure resistance (bar) in accordance with DIN 52320: at least 6 bar Temperature stability of sealing disks and plastic caps shaped butyl rubber disks, center coated with PTFE natural rubber butyl rubber silicone rubber PTFE PE (polyethylene) PP (polypropylene) Allowable variation for the thickness of sealing disks: ±0.25 mm.
3rd hydrolytic class density: 2.5 thermal coefficient of linear expansion (K-1): 85 * 10-7 quenching stability (Δ T in K) in accordance with DIN 52321: 42 internal pressure resistance (bar) in accordance with DIN 52320: at least 6 bar 120°C (-40°C) 140°C 190°C (-30°C) 200°C (-60°C) 250°C 80°C 120 - 130°C
Salvo error u omisión
1169
14. Cromatografía
GENERAL CATALOGUE 2010/11
Viales/Ampollas, Septums, Tapones 1 Viales encapsulables y tapones
1
Los viales encapsulables son frascos para inyecciones con rebordes de 8, 11, 13 ó 20mm que pueden cerrarse con cápsulas de aluminio o tapones de PE (los tapones de PE sólo son para viales con rebordes de diámetros 11 y 20mm).
MACHEREY-NAGEL
Los viales "snap-ring", con reborde de 11mm de diámetro, pueden cerrarse con tapones de PE "snap-on" o cápsulas de aluminio. Los viales cónicos son viales con una cámara interior que se va estrechando, utilizados para muestras de volúmen muy pequeño. Pueden cerrarse con cápsulas de aluminio o tapones de PE. Los micro-inserts se utilizan para reducir el volúmen de los viales habituales para aplicaciones con muestras de volúmen muy pequeño. Los viales se cierran normalmente. Como alternativa a los micro-inserts pueden utilizarse los viales cónicos mencionados con anterioridad. Las cápsulas de aluminio pueden utilizarse en viales encapsulables y "snap-ring". Están disponibles con o sin séptums, con orificio central, con lengüeta de cierre central, etc. Los tapones con orificio central están hechos de aluminio, aluminio con insertos de acero o acero. Éstos dos últimos son magnéticos. Hay disponible una gran diversidad de séptums para las cápsulas de aluminio y los tapones de PE.
Descripción
Capacidad
diámetro / altura
Ø x altura
ud.E
Código
N 8-08, transparente N 11-1 HP, transparente* N 11-1 HP, transparente, con zona de escritura*
ml 0,80 1,50 1,50
mm 8/3 11 / 3 11 / 3
mm 8,2 x 30,0 11,6 x 32,0 11,6 x 32,0
100 100 100
9.003 427 7.086 520 6.700 977
N 11-1 HP, ámbar, con zona de escritura*
1,50
11 / 3
11,6 x 32,0
100
6.700 976
Micro-insert cónico para N11-1 HP
0,20
-
5,5 x 30,0
100
7.401 744
Micro-inserts para N11-1 HP y "snap-ring" con muelle de PP
0,25
-
5,5 x 29,0
100
6.093 247
Vial "snap-ring" N 11-1, transparente* Vial "snap-ring" N 11-1, transparente, con zona de escritura* Vial "snap-ring" N 11-1, ámbar, con zona de escritura* Micro-inserts para "snap-ring", cono pronunciado, punta de 15mm Micro-insert para "snap-ring", punta de 12mm
1,50 1,50
11 / 11 / -
11,5 x 32,5 11,5 x 32,5
100 100
6.073 833 4.001 545
1,50
11 / -
11,5 x 32,5
100
7.059 846
0,20
-
5,5 x 30,0
100
4.001 546
0,30
-
5,5 x 30,0
100
4.001 547
N-13-4, transparente N 20-6 PE, transparente, fondo con bordes redondeados, boca cónica encapsulable N 20-20 PE, transparente, fondo de bordes redondeados y boca cónica encapsulable para inyectores automáticos PE N20-20 HP/CTC, transparente, fondo de bordes redondeados, boca plana encapsulable y cuello largo para inyectores automaticos PE/CTC y HP
4,00 6,00
13 / 3,6 20 / 4
14,75 x 45 22 x 38,25
100 100
4.001 529 7.052 186
20,00
20 / 4
23 x 75,5
100
7.060 463
20,00
20 / 3,6
22 x 75,5
100
9.003 453
*cuello ancho Los viales "snap-ring" N11 pueden utilizarse con los tapones encapsulables N11
1170
Salvo error u omisión
14. Cromatografía
GENERAL CATALOGUE 2010/11
Viales/Ampollas, Septums, Tapones Viales encapsulables y tapones Los viales encapsulables son frascos para inyecciones con rebordes de 8, 11, 13 ó 20mm que pueden cerrarse con cápsulas de aluminio.
MACHEREY-NAGEL
Los viales "snap-ring", con reborde de 11mm de diámetro, pueden cerrarse con tapones de PE "snap-on" o cápsulas de aluminio. Los viales cónicos son viales con una cámara interior que se va estrechando, utilizados para muestras de volúmen muy pequeño. Pueden cerrarse con cápsulas de aluminio o tapones de PE. Los micro-inserts se utilizan para reducir el volúmen de los viales habituales para aplicaciones con muestras de volúmen muy pequeño. Los viales se cierran normalmente. Como alternativa a los micro-inserts pueden utilizarse los viales cónicos mencionados con anterioridad. Las cápsulas de aluminio pueden utilizarse en viales encapsulables y "snap-ring". Están disponibles con o sin séptums, con orificio central, con lengüeta de cierre central, etc. Los tapones con orificio central están hechos de aluminio, aluminio con insertos de acero o acero. Éstos dos últimos son magnéticos. Hay disponible una gran diversidad de séptums para las cápsulas de aluminio y los tapones de PE.
Snap ring caps: Descripción
N 11 transparente N 11 azul N 11 azul
Diám. de orificio mm 6,0 6,0 6,0
N 11 azul
Material / Septum
Espesor / Dureza
ud.E
Código
mm 1,0 / 60 1,3 / 45 1,0 / 45
100 100 100
7.059 844 4.001 544 6.073 555
1,0 / 55
100
6.073 834
Espesor / Dureza
ud.E
Código
Caucho but¡lico y PTFE caucho butilo rojo / PTFE incoloro caucho silicona blanca / PTFE rojo
mm 1,3 / 45 0,9 / 45 1,3 / 45
100 100 100
9.003 441 9.003 443 9.003 444
caucho butilo rojo / PTFE incoloro caucho butilo rojo / PTFE incoloro caucho silicona blanco / PTFE rojo caucho silicona blanco / PTFE rojo disco de caucho butilo gris oscuro con forma / PTFE gris claro
1,3 0,9 1,3 1,3 2,0
45 45 45 45 50
100 100 100 100 100
4.001 7.060 9.003 4.001 7.060
caucho natural rojo anaranjado / PTFE incoloro caucho silicona blanco / PTFE rojo PTFE rojo / caucho silicona blanco / PTFE rojo
6,0 caucho silicona blanco / PTFE azul, ranurado
Crimp caps: Descripción
N 11 TB/oA N 8 TB/oA-4 aluminio color N 8 TS/oA aluminio color N N N N N
11 11 11 11 13
TB/oA aluminio color TB/oA-0.9 aluminio color TS/oA aluminio color TS/oA-M magnetico TB/oA aluminio color
Diám. de orificio mm 5,6 4,0 4,0 5,6 5,6 5,6 5,0 6,0
Material / Septum
/ / / / /
523 469 446 564 475
N20 TB/oA, aluminio color N20 TB/oA, aluminio color
10,0 caucho butilo rojo / PTFE gris 10,0 caucho butilo gris claro / PTFE gris oscuro
3,0 / 55 3,0 / 50
100 100
9.003 454 4.001 549
N20 TS/oA, aluminio color N 20 TS/oA aluminio color
10,0 caucho silicona azul / PTFE incoloro 10,0 caucho silicona crema / PTFE gris
3,0 / 40 3,0 / 60
100 100
4.001 553 9.003 447
N20 TB/HS, aluminio color N20 TS/HS, aluminio color
8,0 caucho butilo rojo / PTFE gris 8,0 caucho silicona crema / PTFE gris
3,0 / 55 3,0 / 60
100 100
9.003 455 9.003 456
N20 TB/oA ASM bimetal, magnetico N20 TS/oA ASM bimetal, magnetico N20 TS/oA ASM bimetal, magnetico
8,0 caucho butilo gris / PTFE gris 8,0 caucho silicona crema / PTFE gris 8,0 caucho silicona azul / PTFE incoloro
3,0 / 50 3,0 / 60 3,0 / 40
100 100 100
9.003 457 9.003 458 6.234 541
Frascos de borde rodado y tapones a presión N 11 Kombi Discos de cierre hermético colocados
MACHEREY-NAGEL
Descripción
ud.E
Código
Combipack N 11-1 HP, incoloro + N 11 N 20 TB/oA tapón de aluminio Disoco o arandela de cierre hermético de goma de butilo rojo/ PTFE incoloro, para HPLC Combipack N11-1 HP, incoloro + N11 TS/oA, tapón de aluminio Arandela de cierre hermético de goma de Silicona blanca / PTFE rojo, para HPLC y GC
1000
9.003 439
1000
9.003 440
Salvo error u omisión
1171
14. Cromatografía
GENERAL CATALOGUE 2010/11
Viales/Ampollas, Septums, Tapones 1
1 Tapones obturadores MACHEREY-NAGEL Descripción
Tapones obturadores N20 de caucho gris claro Tapones obturadores N20 para congelación-liofilización
2
Dureza /
ud.E
Código
Aspecto 37 37
100 100
7.060 433 7.076 651
2 Viales y tapones de rosca Los viales con reborde roscado están disponibles en los tamaños N8, N9 y N13. Éstos utilizan tapones de rosca.
MACHEREY-NAGEL
Los viales cónicos con reborde roscado y paredes de vidrio gruesas son viales para utilizar con muestras de pequeño volúmen, los cuales se cierran con tapones de rosca. Los micro-inserts se utilizan para reducir el volúmen de los viales habituales para aplicaciones con volúmenes de muestra muy pequeños. Los viales se cierran normalmente. Como alternativa se pueden utilizar los viales cónicos comentados anteriormente. Los tapones de rosca pueden encontrarse con o sin septum, y con o sin orificio central. Disponible gran variedad de séptums para los tapones de rosca.
Descripción
Capacidad
Ø x altura
N 8-1, incoloro N 8-1, ámbar N 8-1, ámbar, con zona para escritura Micro-inserts para N8-1, con muelle de PP Micro-inserts para N8-1, transparente estàndard Micro-inserts para N8-1, de cono pronunciado Muelles para micro-inserts, 5 x 30mm N9-1, transparente, boca ancha N9-1, transparente, boca ancha, con zona para escritura
ml 0,00 1,50 1,50 0,25 0,25 0,20 0,00 1,50 1,50
mm 11,5 11,5 x 32,5 11,5 x 32,5 5 x 29 5 x 30 5 x 30
N9-1, ámbar, con zona para escritura, boca ancha N 13-4 G, transparente N 13-4 G, ámbar Micro-inserts para viales N13-4 G Muelles para micro-inserts 6 x 40mm
1,50 4,00 4,00 0,30 0,00
11,6 14,75 14,75 6
11,6 x 32 11,6 x 32 x x x x
32 45 45 40
ud.E
Código
100 100 100 100 100 100 100 100 100
9.003 9.003 7.081 4.001 9.003 7.401 7.086 9.003 4.001
481 480 414 556 435 066 408 448 520
100 100 100 100 100
9.003 9.003 7.058 7.055 4.001
449 482 142 486 567
Combi packs of screw thread vials and screw caps N 8 Sealing wads assembled
MACHEREY-NAGEL
Description Combipack N 8-1, clear + N 8, with phenolic resin screw caps and red / natural seals Combipack N 8-1, clear + N 8, with phenolic resin screw caps and red / white seals
1172
Salvo error u omisión
PK
Cat. No.
1000
9.003 437
1000
9.003 438
14. Cromatografía
GENERAL CATALOGUE 2010/11
Viales/Ampollas, Septums, Tapones 1 Screw caps N 8, N 9, N 13
1
with or without sealing wads
MACHEREY-NAGEL
N 8 8-425 threads N 9 short threads N 13 13-425 threads
Description
Int. bore Material / Sealing disk diameter mm 5.5 Red butyl rubber/clear PTFE 5.5 Red nat. rubber / colourless PTFE
N8* N8*
Thickness / Hardness
PK
Cat. No.
mm / Image 1.3 / 60 1.3 / 60
100 100
9.003 483 6.224 027
N8*
5.5 White silicone rubber / red PTFE w/slit
1.3 / 35
100
6.232 178
N8* N8* N8** N 9 blue*
5.5 5.5 0.0 5.5
White silicone rubber / red PTFE without seal without seal red nat. rubber / colourless PTFE
1.3 / 35 -/-/1.0 / 45
100 100 100 100
9.003 7.060 7.075 9.003
N 9 blue* N 9 blue*
5.5 White silicone rubber / red PTFE 5.5 White silicone rubber / red PTFE w/slit
1.3 / 35 1.3 / 35
100 100
9.003 451 4.001 521
N 13*
8.5 Nat. rubber / PTFE
1.3 / 60
100
4.001 566
N 13*
8.5 White silicone rubber / red PTFE
1.3 / 35
100
7.510 053
Hardness
PK
Cat. No.
Image 60 35 55
100 100 100
7.060 417 7.060 419 7.085 892
ud.E
Código
484 421 960 450
*with centre hole, **witout centre hole
2 Sealing disks N 8
2
Sealing wads for screw caps
Description
N 8 Nat. rubber, red / colourless PTFE N 8 White silicone rubber / red PTFE N 8 White silicone rubber / blue PTFE /slit
MACHEREY-NAGEL
Ext. diam. mm 8 8 8
Wall thickness mm 1.3 1.3 1.0
3 Tenazas de cierre y abertura (manual)
3
Para cerrar herméticamente y manualmente los frascos de muestras con borde rodado MACHEREY-NAGEL o bien para abrilos se necesitan tanto una tenaza de cierre como de abertura. Usted tiene por ejemplo, frascos de muestras con un diámetro de borde rodado de 20 mm y tapones a presión que se adaptan a las dimensiones (por ejemplo, N 20 TB/oA), y dispone ahora de las tenazas de abertura y cierre N20 o N20OE. Las tenazas de cierre que se le ofrecen (excepto N8) son ajustables a las distintas alturas del borde rodado con ayuda de una llave hexagonal adjunta. Descripción Tenaza Tenaza Tenaza Tenaza
de de de de
cierre cierre cierre cierre
ud.E N N N N
8 13 11 20
1 1 1 1
Código 9.003 9.003 9.003 9.003
470 473 471 475
Pinzas para abrir viales Para frascos o viales de muestras, inyecciones e infusiones con tapones de aluminio y combinados. Para Ø mm 1 1 1 1
11 13 20
Salvo error u omisión
9.003 9.003 9.003 9.003
511 367 368 369
1173
14. Cromatografía
GENERAL CATALOGUE 2010/11
Viales/Ampollas, Septums, Tapones Contenedores para viales Disponibles en 3 tamaños diferentes para: viales pequeños (de N8 a N11), viales medianos (N13) y viales grandes (N20). Aptos para congeladores. Apilables. Descripción
MACHEREY-NAGEL
ud.E
Código
81 posiciones, para viales N8, N9 y N11, con inserto integrado, tamaño 130 x 130 x 45mm, codificado, con tapa
1
6.225 649
49 posiciones, para viales N13, con inserto integrado, tamaño 130 x 130 x 50mm, con tapa
1
4.001 527
25 posiciones, para viales N20, con inserto extraíble, tamaño 130 x 130 x 80mm, con tapa
1
4.001 528
ud.E
Código
100 100 100
9.003 600 9.003 601 9.003 602
ud.E
Código
De 0,10 ml, cónico, de vidrio
100
9.003 603
De 0,15 ml, cónico, de vidrio con inserto POLYSPRING De 0,25 ml, con base plana, de vidrio
100
9.003 604
500
9.003 605
ud.E
Código
100 100 100
9.003 606 9.003 607 9.003 608
ud.E
Código
100 100 500
9.003 609 9.003 610 9.003 611
1 Viales para muestras
1
Viales transparentes de vidrio de borosilicato ámbar o incoloro. Se suministran con o sin espacio para rótulos. Medidas: 12 x 32 mm. Con reborde, boca estándar. Tipo 2,0 ml, transparente 2,0 ml, transparente con espacio para rótulos 2,0 ml, ámbar con espacio para rótulos
2 3 4 Insertos Insertos de 5 mm. Tipo
2
5
6
3
4
5 6 Viales Frascos con reborde, boca ancha. Medidas: 12 x 32 mm. Tipo 2,0 ml, transparente 2,0 ml, transparente con espacio para rótulos 2,0 ml, ámbar con espacio para rótulos
7 8 9 Insertos Insertos de 6 mm. Tipo De 0,25 ml, cónico, de vidrio De 0,25 ml, cónico, de vidrio con inserto Polyspring De 0,35 ml, con base plana, de vidrio
7
1174
8
9
Salvo error u omisión
14. Cromatografía
GENERAL CATALOGUE 2010/11
Viales/Ampollas, Septums, Tapones 1 Tapones para viales
1
De aluminio con junta de PTFE, caucho natural o silicona. Con reborde para boca estándar y ancha. Diámetro: 11 mm. Tipo Junta Junta Junta Junta
ud.E de de de de
PTFE PTFE y caucho natural PTFE y silicona PTFE rojo y silicona
1000 1000 100 100
Código 9.003 9.003 9.003 9.003
612 613 614 615
2 Tapones para viales Seal 2000
2
Tapones de aluminio en color y junta de PTFE y caucho. Diámetro: 11 mm. Otros colores bajo pedido. Color
ud.E
Código
Plata
100
9.003 616
3 4 Viales con boca roscada
3
4
Con abertura ancha. Tamaño 12 x 32 mm. Tipo 2,0 ml, transparente 2,0 ml, transparente con espacio para rótulos 2,0 ml, ámbar con espacio para rótulos
ud.E
Código
100 100 100
9.003 617 9.003 618 9.003 619
ud.E
Código
100 100 500
9.003 609 9.003 610 9.003 611
5 6 7 Insertos Insertos de 6 mm Tipo De 0,25 ml, cónico, de vidrio De 0,25 ml, cónico, de vidrio con inserto Polyspring De 0,35 ml, con base plana, de vidrio
5
6
7
8 Tapones roscados
8
Diámetro: 10 mm. Tapones roscados abiertos de polipropileno, en varios colores. Color
ud.E
Negro Rojo Azul Verde
100 100 100 100
Código 9.003 9.003 9.003 9.003
620 621 622 623
9 Septums
9
Septums. 10 mm. Tipo
ud.E
Código
PTFE PTFE rojo/silicona blanca
1000 100
9.003 624 9.003 627
Salvo error u omisión
1175
14. Cromatografía
GENERAL CATALOGUE 2010/11
Viales/Ampollas, Septums, Tapones 1 2 Viales con boca roscada Con abertura estándar. Tamaño 12 x 32 mm. Tipo 2,0 2,0 2,0 2,0
ml, ml, ml, ml,
ud.E transparente transparente con espacio para rótulos ámbar ámbar con espacio para rótulos
1
100 100 100 100
Código 9.003 9.003 9.003 9.003
629 630 631 632
2 4
3
5
3 4 5 Insertos Insertos de 5 mm. Tipo
ud.E
Código
De 0,10 ml, cónico, de vidrio De 0,15 ml, cónico, de vidrio con inserto POLYSPRING
100 100
9.003 603 9.003 604
De 0,25 ml, con base plana, de vidrio
500
9.003 605
Tipo
ud.E
Código
Fenol, negro PP, negro
1000 100
9.003 633 9.003 634
Tipo
ud.E
Código
PTFE PTFE/Caucho PTFE rojo/silicona blanca
1000 100 100
9.003 635 9.003 636 9.003 638
7
6
6 7 Tapones roscados Diámetro: 8 mm. Tapones roscados abiertos.
8
8 Septums Septums. 8 mm.
9
9 Septums tricapa, para altas temperaturas Temperatura máxima de trabajo: 200°C. Ø mm 9,5 10,0 13,0
1176
Salvo error u omisión
Hamilton ud.E
Código
12 12 12
9.221 803 9.221 805 9.221 809
Filtration MACHEREY-NAGEL
Find out about high-quality products for filtration. As one of the leading filter paper manufacturers, we offer more than 7000 products from the following ranges:
• Quantitative (ashless) filter papers • Qualitative filter papers • Glass fibre filters • Filter papers for technical applications • Extraction thimbles • PORAFIL® filter membranes • CHROMAFIL® syringe filters • CHROMABOND ® MULTI 96 filters • Special products and costum-made products • ... and many more
Quality „Made in Germany“
We produce our filter papers exclusively in Germany. Thereby we guarantee constant high quality for our customers. With pride we look back to a almost 100-year-old successful history. Founded in 1911 MACHEREYNAGEL today is a worldwide operating company. We develop and produce a large number of special products for analytical chemistry.
• Filter and filtration products • Rapid tests for environmental, process and food analysis • Test papers for medical urine analysis • Consumables for chromatography • Kits for purification of DNA and proteins
Be prepared for the future
Rely on MACHEREY-NAGEL filter papers at any time in the future. As a family-owned company the friendly expert advice for our highly-valued customers as well as outstanding product quality have been the cornerstones of our corporate success for almost 100 years.
MACHEREY-NAGEL
14. Cromatografía
GENERAL CATALOGUE 2010/11
Jeringas/Jeringas de microlitros 1 Jeringas de microlitros, códigos 1
N (aguja) Jeringas con aguja estándar cementada. La aguja de acero fino se ha fijado en un cuerpo de vidrio de manera que coincide con el punto cero.
Hamilton
LTN (aguja tipo Luer) Jeringas con aguja cementada en cuerpos de vidrio que se estrechan. En las jeringas de la serie 1000 (= 1ml) se fija la aguja en el cono Luer. SN (aguja especial) Jeringas, cuyas agujas tienen unas medidas especiales. Para fabricar las puntas SN se necesitan los datos siguientes: Longitud, diámetro (gauge), forma de la jeringa, puntas estrechadas electrolíticamente (electroafilado). Se emplean los valores estándar donde no aparecen indicaciones especiales. Ejemplo de una especificación exacta: 701 SN, 70 mm, Gauge 25, pst.3, afilada RN (aguja extraible) Jeringas con agujas intercambiables. Las agujas RN se ajustan asimismo como agujas firmemente cementadas al punto cero de la escala. Por lo tanto su conexión está libre de volumen muerto. Las agujas para las jeringas con un volumen de 5 hasta 100 µl son fácilmente intercambiables, y lo mismo ocurre con las agujas para las puntas con un volumen de 250 µl hasta 10 ml. LT (Punta Luer) El cuerpo de vidrio de esta jeringa tiene un final cónico de vidrio, que se puede calentar a más de 100º. Se pueden acoplar agujas Luer a las jeringas de punta Luer. Las jeringas LT se suministran sin cánula. C (Cheminert) Este tipo de jeringas dispone de un cierre o final de rosca C estándar (1/4 Zoll-28 UNF). Las jeringas de este tipo se pueden atornillar a miniválvulas. TLL, TLLX (Teflonfi Cierre Luer) Adicionalmente al cierre de Teflon fi cónico, las jeringas de este tipo disponen de un manguito de rosca de doble vía. Las puntas TLL son adecuadas para su uso en diluidores y dispensadores HAMILTON así como en otros muchos sistemas dosificadores. Las jeringas TLL se suministran sin agujas. Se pueden emplear agujas con una pieza de metal (identificación:N) y con una pieza de PCTFE (identificación:KF). Las jeringas se alteran si se calientan por encima de los 50ºC. AD (AccuDilfi ) Las jeringas de esta serie se han desarrollado especialmente para aparatos dosificadores. Se atornillan directamente con una rosca fina (M8x0,75) al soporte. No existe una escala. DAD (Diluter AccuDilfi ) Estas jeringas disponen de una rosca fina axiaal (M8x0,75) y un cierre M6 lateral. Como las jeringas D se emplean en diluidores. SL (SampleLock) La jeringa SampleLock se emplea para la recogida, almacenamiento y cesión de muestras de gas y líquido.
1178
Salvo error u omisión
14. Cromatografía
GENERAL CATALOGUE 2010/11
Jeringas/Jeringas de microlitros 1 Jeringas de microlitros, formas de las puntas Forma de punta 2: Forma de punta estándar con un afilado de 12º, ligeramente inclinada hacia dentro (Protección ante el taponamiento). Ideal para la cromatografía de gases
Hamilton
1
Forma de punta 3: Punta con un afilado de 90º. Para la dosificación exacta en las aplicaciones de cromatografía de capa fina y de alta resolución. Forma de punta 4: Estas agujas tienen una inclinación. Se utilizan para aplicaciones en veterinaria y ciencias de la vida. Forma de punta 5: Estas agujas tienen un final cerrado. La abertura lateral impide un taponamiento de la aguja al penetrar el septum. Estas agujas se encuentran disponibles en 26S, 23 y 23S Forma de punta AS: Con un cono de 8*afilado por el frontal. Especial para el automuestreo en CG.
2 Jeringas tipo Hamilton, serie 700
2
Con aguja cimentada (N, NR). Los tipos NR son especificados por Rheodyne. Embolos esmerilados individualmente, por lo que no son intercambiables y no se suministran como repuesto. Las agujas se afilan electrolíticamente. Longitud Aguja Tipo 75 N 701 N 701 N 702 N 705 N 710 N 725 N 750 N 701 702 705 710 725
N NR NR NR NR
Hamilton
51 mm Capacidad µl 5 10 10 25 50 100 250 500 5 10 25 50 100 250 500
Calibre
Puntas
26s 26s 26s 22s 22s 22s 22s 22s
2 2 2 2 2 2 2 2
26s 22s 22s 22s 22s
3 3 3 3 3
ud.E 1 1 6 1 1 1 1 1 1 1 1 1 1 1 1
Código 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221 6.055
001 002 010 003 004 005 006 007 011 012 013 014 015 016 335
3 Jeringas tipo Hamilton, serie 700
3
Aguja desenroscable (RN). El émbolo ha sido esmerilado individualmente, por lo que no es intercambiable y no se suministra como repuesto. Las agujas se afilan electrolíticamente.
Longitud Aguja Forma de punta Tipo 75 RN 701 RN 701 RN 702 RN 705 RN 710 RN 725 RN 750 RN 701 LT 702 LT 705 LT 710 LT 725 LT 750 LT
Hamilton
51 mm 2 (GC) Capacidad µl 5 10 10 25 50 100 250 500 10 25 50 100 250 500
Calibre
Puntas
26s 26s 26s 22s 22s 22s 22s 22 26s 22s 22s 22s 22s 22
2 26s 2 2 22s 2 2 2
ud.E 1 1 6 1 1 1 1 1 1 1 1 1 1 1
Salvo error u omisión
Código 9.221 9.221 6.059 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221
080 081 899 082 083 084 085 086 021 022 023 024 025 026
1179
14. Cromatografía
GENERAL CATALOGUE 2010/11
Jeringas/Jeringas de microlitros 1
1 Agujas para RN Desenroscables. No apropiadas para HPLC. Longitud Modelo de punta Tipo
2
51 mm 2 (GC)
Ø ext. mm 0,5 0,7 0,7 0,7
7758-02 7758-03 7779-01 7779-03
Hamilton
Ø int. mm 0,13 0,15 0,41 0,15
Calibre
26s 22s 22s 22s
Capacidad
ud.E
2,5 µl - 100 µl 2,5 µl - 100 µl 250 µl - 10 ml 250 µl - 10 ml
6 6 6 6
Calibre Longitud Aguja Forma de punta Tipo 85 N 801 N 802 N 805 N 810 N 825 N
26s 51 mm 2 (GC)
Capacidad µl 5 10 25 50 100 250
Calibre
Puntas
26s 26s 22s 22s 22s 22s
2 2 2 2 2 2
ud.E 1 1 1 1 1 1
Código 9.221 9.221 9.221 9.221 9.221 9.221
105 110 111 112 113 114
3 Jeringas tipo Hamilton, serie 800
Galga Longitud aguja Forma de punta Tipo 85 RN 801 RN 802 RN 805 RN 810 RN 825 RN 85 RN 801 RN 810 RN 85 RN B/P 801 RN B/P
Hamilton
26s 51 mm 2 (GC)
Capacidad µl 5 10 25 50 100 250 5 10 100 5 10
Calibre
Puntas
26s 26s 22s 22s 22s 22s 26s 26s 22s 2 2
2 2 2 2 2
5 10
ud.E 1 1 1 1 1 1 1 1 1 1 1
Código 9.221 9.221 9.221 9.221 9.221 9.221 6.222 6.231 6.803 9.221 9.221
115 116 117 118 119 120 013 153 384 171 172
4 Puntas de microlitros, serie 1700/1000. Con punta de émbolo0 de teflon, con conexión Luer (LT). Puntas de microlitros herméticas al gas sin cánulas MS = Tope de émbolo para no sobrecargar la junta de teflon. Tipo
1710 1725 1750 1001 1002 1005
1180
692 693 694 695
Hamilton
Modelos RN completos, con empuñadura metálica Modelos RN B/P sólo jeringa, sin empuñadura metálica (jeringas de repuesto).
4
9.221 9.221 9.221 9.221
2 Jeringas microlitros, serie 800 Con aguja estándar cimentada (N). Empuñadura metálica. El émbolo ha sido esmerilado individualmente, por lo que no es intercambiable y no se suministra como repuesto. Las agujas se afilan electrolíticamente.
3
Código
Capacidad
LT LT LT LT LT LT
µl 100 250 500 1000 2500 5000
Graduación µl 1 5 10 10 50 100
Salvo error u omisión
Hamilton
ud.E
1 1 1 1 1 1
Código
9.221 9.221 9.221 9.221 9.221 9.221
210 225 250 251 252 255
14. Cromatografía
GENERAL CATALOGUE 2010/11
Jeringas/Jeringas de microlitros 1 Puntas de microlitros serie 1700/1000
1
Con puntas de émbolo de teflon /Luer-Lock (TLL). Tipo TLLX con rosca hembra 6-32 UNC. Permite la conexión a los mecanismos del brazo impulsor, por ejemplo, diluidores/dispensadores Microlab serie 500. Jeringas herméticas al gas, sin aguja.
Hamilton
MS = Tope de émbolo para no sobrecargar la junta de teflon. Tipo
1702 1705 1710 1725 1750 1001 1001 1001 1002 1005 1010 1025 1025
Capacidad
Graduación µl 0,25 0,5 1 5 10 10 20 0,01 50 100 200 500 0,25
µl 25 50 100 250 500 1000 1000 1000 2500 5000 10000 25000 25000
TLLX TLLX TLLX/MS TLLX/MS TLLX/MS TLL TLL/MS TLLX TLL TLL TLL TLL TLL
ud.E
1 1 1 1 1 1 1 1 1 1 1 1 1
Código
9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221
300 305 310 315 320 348 325 328 330 335 340 347 345
2 Cánulas para puntas de microlitros LT/TLL/TLLX
2
Encajables. Con conexión Luer de Kel-F. Todas las agujas se suministran bajo pedido en longitudes que van desde 10 hasta máximo 1.100 mm. Longitud Aguja Tipo
KF KF KF KF KF KF
51 mm Ø ext. mm 0,5 0,7 1,1 3,4 0,7 0,7
726 722 719 710 722 S 722 PsT 3
Hamilton
Ø int. mm 0,30 0,40 0,70 0,70 0,20 0,40
Calibre
Puntas
26 22 19 10 22s 22
2 2 2 2 3 3
ud.E
6 6 6 6 6 6
Código
9.221 9.221 9.221 9.221 9.221 9.221
626 622 619 610 607 722
3 Puntas de microlitros, serie 1700/1000
3
Jeringas tipo Hamilton con aguja desenroscable (RN). Aguja cimentada Forma de punta Tipo 1701 1702 1705 1710 1725 1750 1001 1002
RN RN RN RN RN RN RN RN
Capacidad µl 10 25 50 100 250 500 100 2500
Hamilton
51 mm 2 (GC) Calibre 26 22 22 22 22 22 22 22
ud.E
s s s s s
1 1 1 1 1 1 1 1
Código 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221
487 488 489 490 491 492 493 494
4 Jeringas tipo Hamilton, serie 1700/1000
4
Punta del émbolo de teflón. Jeringas herméticas con aguja cimentada (N). Aguja afilada electrolíticamente (LTN). Longitud Aguja Puntas Tipo 1701 1702 1705 1710 1725 1750 1001 1002 1005 1010
N N N N N LTN LTN LTN LTN LTN
Capacidad µl 10 25 50 100 250 500 1000 2500 5000 10000
Hamilton
51 mm 2 Calibre
ud.E
26s 22s 22s 22s 22s 22 22 22 22 22
1 1 1 1 1 1 1 1 1 1
Salvo error u omisión
Código 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221
448 449 450 455 460 465 470 475 480 485
1181
14. Cromatografía
GENERAL CATALOGUE 2010/11
Jeringas/Jeringas de microlitros Jeringas tipo Hamilton, serie 800 Con aguja estándar cimentada (N). Empuñadura metálica. El émbolo ha sido esmerilado individualmente, por lo que no es intercambiable y no se suministra como repuesto.
Hamilton
Las agujas se afilan electrolíticamente.
26s 51 mm 2 (GC)
Galga Longitud Aguja Forma de punta Capacidad µl 10 25 50 100 250 10 25 50 100 250
Tipo 1801 1802 1805 1810 1825 1801 1802 1805 1810 1825
1
N N N N N RN RN RN RN RN
Calibre
Puntas
26s 22s 22s 22s 22s 26s 22s 22s 22s 22s
2 2 2 2 2 2 2 2 2 2
ud.E 1 1 1 1 1 1 1 1 1 1
Código 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221 9.221
836 837 838 839 840 831 832 833 834 835
1 Puntas de microlitros, serie 7000 Con aguja intercambiable /unidad de émbolo.
Hamilton
Dosificación según el principio de desplazamiento positivo mediante alambre de volframio en la aguja, sin volumen muerto. Piezas individuales recambiables.
Longitud Aguja Tipo 7000.5 KH 7001 KH 7101 KH 7002 KH 7102 KH 7105 KH 7000.50C KH 7000.5 KH 7001 KH 7101 KH 7002 KH 7102 KH 7105 KH
70 mm Volumen µl 0,5 1,0 1,0 2,0 2,0 5,0 0,5 0,5 1,0 1,0 2,0 2,0 5,0
Calibre
Puntas
50 47 70 50 63 56 23 50 47 70 50 63 56
2 2 2 2 2 2 3 3 3 3 3 3 3
ud.E 1 1 1 1 1 1 1 1 1 1 1 1 1
Código 6.700 9.221 6.802 6.204 6.801 9.221 9.221 9.221 6.802 9.221 9.221 9.221 6.050
111 121 391 624 037 125 590 126 598 131 122 132 160
Spare unit for Microlitre syringes, 7000 series Hamilton Type Spare Spare Spare Spare Spare Spare
2
PK unit unit unit unit unit unit
for for for for for for
syringes syringes syringes syringes syringes syringes
7000.5 7001 7002 7105 7101 7102
1 1 1 1 1 1
9.221 9.221 9.221 9.221 9.221 9.221
181 182 183 184 185 186
2 Cánulas para HPLC Desenroscables. Sistema Rheodyne y Valco VISF 2. Para jeringas Hamilton de 5 - 100 µl. Galga Longitud aguja Forma de punta Tipo
7770-01
1182
Cat. No.
Hamilton
22s 51 mm 3 (HPLC) Capacidad
ud.E
Código
2,5 µl - 100 µl
6
9.221 603
Salvo error u omisión
14. Cromatografía
GENERAL CATALOGUE 2010/11
Jeringas/Jeringas de microlitros Puntas microlitros para automuestreo GC Con agujas cementadas (N). Para automuestreo CG Hewlett-Packard 7670 A, 7671 A, 7672 A. Calibre: Longitud aguja Puntas Tipo 701 N 1701 N
Hamilton
26s 51 mm 2
Capacidad µl 10 10
ud.E
Código
1 1
9.221 002 9.221 448
1 Puntas microlitros para automuestreo GC
1
Con agujas cementadas (N). Para automuestreo: - Hewlett-Packard 7673 A. Calibre: Longitud aguja: Puntas: Tipo 701 ASN 23S
Hamilton
23s 43 mm AS (GC) Capacidad µl 10
ud.E
Código
1
9.221 196
2 Dispositivo para dosificaciones reproducibles
2
Para jeringas de 25 µl a 2,5 ml. Cada vez que se pulsa el botón el dispositivo dosifica el 2% del volumen total de la jeringa. Tipo PB 600-1
Hamilton
ud.E
Código
1
9.221 650
N´hesitez pasofercie à Podemos suministrar W naszej Possiamo l’intera We can supply this wir liefern das toda la мы поставляем
nous consulter pour znajdziecie Państwo pełny gesamte Programm gama de productos di всю продукцию di manufactorer’s tout autre modèle de este whole zakres produktów!
produttore. des fabricante! Herstellers производителя de cetterange marque.! product
Salvo error u omisión
1183
14. Cromatografía
GENERAL CATALOGUE 2010/11
Preparación de muestras/SPE
Basic principles of SPE SPE is a form of digital (step-wise) chromatography designed to extract, partition, and / or adsorb one or more components from a liquid phase (sample) onto a stationary phase (adsorbent or resin). An adsorbed substance can be removed from the adsorbent by step-wise increase of elution strength of the eluent (step gradient technique). SPE extends a chromatographic system’s lifetime, improves qualitative and quantitative analysis, and the demand placed on an analytical instrument is considerably lessened.
In general, SPE is used for three important purposes in stateof-the-art analyses: Solid phase extraction (SPE) is a powerful method for sample preparation and is used by most chromatographers today. More than 20 years ago MACHEREY-NAGEL designed and introduced CHROMABOND® SPE cartridges containing silica-based adsorbents. Since then we developed the widest range of phases and products for SPE based on silica and polymeric materials. SPE has capabilities in a broad range of applications: pharmaceutical and biochemical analyses
removal of interfering compounds (protection of subsequent analyses like HPLC, GC, TLC, UV or IR spectroscopy, …) changing an analyte’s environment to a simpler matrix more suitable for subsequent analyses Advantages of SPE compared to classical liquid-liquid extraction:
organic chemistry
lower consumption of solvents
food analysis
faster – enormous time savings lower costs per sample potential for automation
ge
il So
Ve
ta
bl
e
high consistency in individual sample handling Ta ble Bl ts oo d
Ur ine
Drinking water
d Foo
Solid phase extraction
environmental analyses
concentration of the analyte (up to factor 10.000 - increase of chromatographic sensibility / improved limits of detection)
te
PRUH VSHFL¿ F VHOHFWLYLW\ EHFDXVH RI WKH EURDG UDQJH RI DGVRUEHQWV and different retention mechanisms l oi
optimisation of extraction by variation or adjusting of the solid phase and chromatographic conditions
as
W
Fruit Separation of food additives 1. Acesulfam K 2. Saccharin 3. Benzoic acid 4. Sorbic acid 5. Aspartam
1 Pesticides PAHs PCBs Drugs Dyes Vitamins
1184
2
3
4
5
before SPE
after SPE time [min] A
Salvo error u omisión
14. Cromatografía
GENERAL CATALOGUE 2010/11
Preparación de muestras/SPE
Basic principles of SPE
CHROMABOND®
CHROMAFIX®
sample reservoir
CHROMABOND® LV
CHROMABOND® MULTI 96
sample reservoir
/XHU ¿ WWLQJ IHPDOH
polypropylene or glass
84 72.3
1°
SRO\SURS\OHQH PO
90
.
DGVRUEHQW /XHU WLS ¿ OWHU male HOHPHQWV
¿ OWHU HOHPHQWV DGVRUEHQW
DGVRUEHQW /XHU WLS ¿ OWHU HOHPHQWV
DGVRUEHQW /XHU WLS ¿ OWHU HOHPHQWV
Solid phase extraction
Design of columns, cartridges and 96-well plates All CHROMABOND® FROXPQV FDUWULGJHV DQG ZHOO SODWHV DUH PDQXIDFWXUHG IURP SRO\SURS\OHQH 33 ZLWK ORZHVW FRQWHQW RI H[WUDFWDEOHV SODVWLFL] HUV VWDELOLVHUV « RIIHULQJ EODQN YDOXH IUHH UHVXOWV E\ XVDJH RI PRVW FRPPRQ VROYHQWV 7KH KLJK TXDOLW\ &+520$%21'® DGVRUEHQWV DUH NHSW LQ SODFH E\ FKHPLFDOO\ YHU\ LQHUW SRO\HWK\OHQH ¿ OWHU HOHPHQWV 3( VWDQGDUG SRUH VL]H P CHROMABOND® polypropylene columns
CHROMABOND® LV columns
33 FROXPQV ZLWK 3( ¿ OWHU HOHPHQWV
ODUJH YROXPH 33 FROXPQV ZLWK 3( ¿ OWHU HOHPHQWV
GLIIHUHQW VL]HV IURP XS WR PO
WKUHH GLIIHUHQW DGVRUEHQW ZHLJKWV DQG PJ
DGVRUEHQW ZHLJKWV IURP PJ WR J
IXQQHO VKDSHG UHVHUYRLU ZLWK PO YROXPH
PDOH OXHU WLS DV H[LW
HVSHFLDOO\ IRU FOLQLFDO VDPSOHV WKH ZKROH VDPSOH H J XULQH VHUXP EORRG FDQ EH DSSOLHG WR WKH FROXPQ LQ RQH VWHS
FRPSDWLEOH ZLWK PRVW URERWV H J *LOVRQ $63(& &DOLSHU $XWR7UDFH® «
FDQ EH GLUHFWO\ XVHG LQ WKH =\PDWH® ODE URERWV RI =\PDUN
CHROMABOND® glass columns
CHROMABOND® MULTI 96 · SPE in 96-well format
JODVV FROXPQV ZLWK FKHPLFDOO\ YHU\ LQHUW JODVV ¿ EUH ¿ OWHU HOHPHQWV QRPLQDO SRUH VL]H P
WZR GLIIHUHQW VL]HV DQG PO
ZHOO SRO\SURS\OHQH SODWHV ZLWK 3( ¿ OWHU HOHPHQWV DGVRUEHQW ZHLJKWV IURP WR PJ VXSSOLHG ZLWK DQ\ &+520$%21'® 63( DGVRUEHQWV
DYDLODEOH ZLWK DOO &+520$%21'® SKDVHV
H[FOXGHV DQ\ LQÀ XHQFH IURP WKH FROXPQ PDWHULDO H J SODVWLFL]HUV «
CHROMAFIX® cartridges
IRU VLPXOWDQHRXV SUHSDUDWLRQ RI VDPSOHV HDV\ PHWKRG WUDQVIHU IURP &+520$%21'® columns or CHROMAFIX® FDUWULGJHV WR &+520$%21'® 08/7, UHDGLO\ DGDSWDEOH WR DOO FRPPRQ DXWRPDWHG URERWLF KDQGOLQJ V\V WHPV
33 FDUWULGJHV ZLWK 3( ¿ OWHU HOHPHQWV WKUHH GLIIHUHQW VL]HV ZLWK GLIIHUHQW DGVRUEHQW ZHLJKWV Small PO MHGLXP PO LDUJH PO
IHPDOH /XHU WLS DW WKH LQOHW PDOH /XHU WLS DV H[LW RIIHUV DOWHUQDWLYH ZD\ RI KDQGOLQJ XVLQJ SRVLWLYH SUHVVXUH E\ V\ULQJHV RU SHULVWDOWLF SXPSV HVSHFLDOO\ VXLWHG IRU FRQYHQLHQW VROLG SKDVH H[WUDFWLRQ RI VPDOO VDPSOH volumes
Salvo error u omisión
1185
14. Cromatografía
GENERAL CATALOGUE 2010/11
Preparación de muestras/SPE
Summary of MN phases for SPE
Phase Matrix RP phases HR-X 36 '9% Easy 36 '9%
0RGL¿ FDWLRQ $SSOLFDWLRQ
PS-RP
36 '9%
UHPRYDO RI RUJDQLF FRPSRQHQWV
& HF
VLOLFD
RFWDGHF\O HQGFDSSHG
&
VLOLFD
RFWDGHF\O QRW HQGFDSSHG
6LPLODU SKDVHV (19, &KURP 3 6WUDWD ; 2DVLV® +/% 1H[XV 6WUDWD ; 2DVLV® +/% 3RUDSDN 5'; 1H[XV %RQG (OXW® 33/ )RFXV 6W\UH 6FUHHQ® '9% %DNHUERQG +22 SKLOLF '9% ,VROXWH® (19 6WUDWD 6'% / %RQG (OXW® (19 %RQG (OXW® /06 '&6 36 '9% (19 36 '9% %DNHUERQG +22 SKRELF '9% ,VROXWH® 6WUDWD & ( 6HS 3DN® W& %RQG (OXW® & '6& /W (19, /& &/($1 83® & %DNHUERQG® 2FWDGHF\O ,VROXWH & (& /L&KUROXW 53 ( 6WUDWD & 8 $FFXERQG® & %DNHUERQG 3RODU3OXV ,VROXWH® & /L&KUROXW® 53
SRODU ELIXQFWLRQDO
& +\GUD VLOLFD & VLOLFD
RFWDGHF\O QRW HQGFDSSHG IRU SRODU DQDO\WHV RFW\O
&6H5
SKHQ\O
VLOLFD
XQPRGL¿ HG
NH2
VLOLFD
DPLQRSURS\O
2+ &1
VLOLFD VLOLFD
GLRO &\DQR
6WUDWD 6L %RQG (OXW® VLOLFD '6& 6L /& 6L &/($1 83® VLOLFD $FFXERQG® VLOLFD %DNHUERQG VLOLFD JHO ,VROXWH® VLOLFD /L&KUROXW® 6L 6WUDWD 1+2 6HS 3DN® 1+2 %RQG (OXW 1+2 '6& 1+2 /& 1+2 &/($1 83® DPLQRSURS\O $FFXERQG® 1+2 %DNHUERQG DPLQR ,VROXWH® 1+2 /L&KUROXW® 1+2 '6& 'LRO /& 'LRO $FFXERQG® 'LRO 2+
6WUDWD &1 6HS 3DN® &1 %RQG (OXW® &1 8 '6& &1 /& &1 &/($1 83® &1 $FFXERQG® &1 %DNHUERQG F\DQR ,VROXWH® &1 /L&KUROXW® &1 /& $OXPLQD $ 1 % $FFXERQG® DOXPLQLXP R[LGH $ 1 % 6WUDWD )/ 35 6HS 3DN® )ORULVLO® %RQG (OXW® )ORULVLO® (19, )ORULVLO® /& )ORULVLO® &/($1 83® )ORULVLO® $FFXERQG® )ORULVLO® %DNHUERQG )ORULVLO® ,VROXWH® )/ /L&KUROXW® )ORULVLO® '3$ 6
$OR[ $ 1 % DOXPLQLXP R[LGH DFLGLF QHXWUDO EDVLF )ORULVLO® PDJQHVLXP VLOLFDWH
3$ SRO\DPLGH Ion exchangers 6% VLOLFD
TXDWHUQDU\ DPPRQLXP DQLRQ H[FKDQJHU 6$;
6$
VLOLFD
EHQ]HQHVXOSKRQLF DFLG FDWLRQ H[FKDQJHU 6&;
36$ +5 ;&
VLOLFD 36 '9%
SURS\OVXOSKRQLF DFLG FDWLRQ H[FKDQJHU VWURQJ PL[HG PRGH FDWLRQ H[FKDQJHU IRU EDVLF DQ DO\WHV 0&;
36 2+– 36 '9% VWURQJ DQLRQ H[FKDQJHU 2+– IRUP PS-H 36 '9% VWURQJ FDWLRQ H[FKDQJHU + IRUP 36 $J 36 '9% VWURQJ FDWLRQ H[FKDQJHU $J IRUP 36 %D 36 '9% VWURQJ FDWLRQ H[FKDQJHU %D IRUP Phases for special applications 'UXJ VLOLFD ELIXQFWLRQDO & 6$ IRU HQULFKPHQW RI GUXJV IURP XULQH
'UXJ ,,
VLOLFD
&1 6L2+ VLOLFD NH2 & VLOLFD Na2624 )ORULVLO® 6$ 6L2+ VLOLFD 6L2+ + VLOLFD 6$ 1$1 VLOLFD $J12 1D2624 'LDPLQR VLOLFD
ELIXQFWLRQDO & 6% IRU H[WUDFWLRQ RI 7+& DQG GHULYD WLYHV DV ZHOO DV DFLGLF DQDO\WHV IURP ELRORJLFDO À XLGV FRPELQDWLRQ SKDVH IRU 3$+V IURP VRLO FRPELQDWLRQ SKDVH IRU 3$+V IURP ZDWHU FRPELQDWLRQ SKDVH IRU H[WUDFWLRQ RI K\GURFDUERQV IURP ZDWHU ',1 + ,62 ',6
FRPELQDWLRQ SKDVH IRU 3&%V IURP ZDVWH RLO FRPELQDWLRQ SKDVH WRJHWKHU ZLWK 6L2+ IRU HQULFKPHQW RI 3&%V IURP RLO FRPELQDWLRQ SKDVH IRU HQULFKPHQW RI 3&%V IURP VOXGJH
6WUDWD 6$; 6HS 3DN® 6$; %RQG (OXW® 6$; '6& 6$; /& 6$; &/($1 83® 4XDWHUQDU\ $PLQH $FFXERQG® 6$; %DNHUERQG 4XDWHU QDU\ $PLQH ,VROXWH® 6$; /L&KUROXW® 6$; 6WUDWD 6&; %RQG (OXW® 6&; '6& 6&; /& 6&; &/($1 83® %HQ]HQHVXOIRQLF $FLG $FFXERQG® 6&; %DNHUERQG $URPDWLF 6XOIRQLF $FLG ,VROXWH® 6&; /L&KUROXW® 6&; 2DVLV® 0&; 6WUDWD ; & 6W\UH 6FUHHQ® '%; 2DVLV® 0$; 2DVLV® 0&; 6WUDWD ; &
6WUDWD 6FUHHQ & %RQG (OXW® &HUWLI\ , '6& 0&$; &OHDQ 6FUHHQ® '$8 $FFXERQG® (YLGH[ %DNHUERQG 1DUF ,VROXWH® +&; /L&KUROXW® 76& 6WUDWD 6FUHHQ $ %RQG (OXW &HUWLI\ ,, &OHDQ 6FUHHQ® 7+& %DNHUERQG® 1DUF ,VROXWH® +$;
pULPDU\ DQG sHFRQGDU\ DPLQH IXQFWLRQV 36$ IRU GH 6XSHOFOHDQ 36$ %RQG (OXW 36$ WHUPLQDWLRQ RI SHVWLFLGHV LQ IRRG 4X(&K(56 PHWKRG
SKDVHV ZKLFK SURYLGH D VLPLODU VHOHFWLYLW\ EDVHG RQ FKHPLFDO RU SK\VLFDO SURSHUWLHV OLVW QRW FRPSOHWH
1186
Salvo error u omisión
Solid phase extraction
Normal phases 6L2+ VLOLFD
6WUDWD & 6HS 3DN® & %RQG (OXW® & '6& (19, /& &/($1 83® & $FFXERQG® & %DNHUERQG 2FW\O ,VROXWH & (&
6WUDWD 3+ %RQG (OXW® 3+ '6& 3K &/($1 83® 3KHQ\O $FFXERQG® 3KHQ\O %DNHUERQG 3KHQ\O ,VROXWH 3+ (&
14. CromatografĂa
GENERAL CATALOGUE 2010/11
PreparaciĂłn de muestras/SPE 1 Chromabondfi HR-X
1
hydrophobic polystyrene-divinylbenzene copolymer MACHEREY-NAGEL pH stability 1 to14 high-purity material with highest reproducibility and lowest blank values due to a novel manufacturing process spherical particles 85¾m; pore size 55 to 60Å very high surface 1000m²/g capacity 390mg/g (caffeine in water) excellent recovery rates especially for the enrichment of pharmaceuticals/active ingredients due to the spherical structure of the particles, very homogeneous surface, and optimised pore structure recommended applications: pharmaceuticals/active ingredients from tablets, creams and water/waste water drugs and pharmaceuticals from urine, blood, serum and plasma trace analysis of pesticides
Capacity
Capacity
PK
mg 30 60 100 200 200 500 500 500 1000 200 200
30 30 30 30 30 30 30 20 20 250 250
ml 1 3 1 3 6 3 6 15 15 3 6
Cat. No.
4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003
808 811 809 807 814 813 818 819 820 806 815
BIGpacks: 4.003 806/4.003 815
Highest reproducibility within each batch Compounds:
Standard protocol for method development with CHROMABONDÂŽ HR-X Column type: CHROMABONDÂŽ HR-X 3 ml / 200 mg Sample pretreatment: if necessary, adjust pH value Column conditioning: 5 ml methanol Equilibration: 5 ml water Sample application: slowly aspirate the sample through the column Column washing: PO ZDWHU Âą PHWKDQRO Y Y
Elution: after drying 3 x 2 ml methanol
from batch to batch 100
A phenobarbital B pentobarbital C hexobarbital
50
0
A B C
A B C
A B C
Batch 1
Batch 2
Batch 3
Further analysis: if necessary, evaporate and redissolve in a suitable VROYHQW +3/& RU *&
Barbiturates from serum Column type: ÂŽ CHROMABOND HR-X 3 ml / 200 mg Sample: QJ PO HDFK LQ VHUXP Column conditioning: 5 ml methanol, 5 ml dist. water Sample application: 1 ml spiked serum Column washing: 5 ml water Elution: after drying 3 x 2 ml methanol Further analysis: +3/& RQ 18&/(2'85ÂŽ &18 ec, see MN Appl. 1R 01 $SSO 1R
Salvo error u omisiĂłn
01 $SSO 1R
1187
14. CromatografĂa
GENERAL CATALOGUE 2010/11
PreparaciĂłn de muestras/SPE CHROMABONDfi Easy CopolĂmero de poliestireno-divinilbenceno modificado polar con un intercambiador aniĂłnico dĂŠbil
MACHEREY-NAGEL
Superficie especĂfica 650 a 70m2/g, tamaĂąo de partĂcula de 80 Âľm, tamaĂąo de poro 50 A, estabilidad del pH 1 a 14. Debido a las modificaciones bifuncionales, polĂmeros de poliestireno-divinilbenceno mucho mĂĄs hidrofĂlicos que convencionales y por consiguiente fĂĄcilmente mojables con agua Aplicaciones recomendadas: - herbicidas/pesticidas polares de agua (ĂĄcidos, neutros, bĂĄsicos) - fenoles polares del agua - compuestos poliaromĂĄticos - bifenilos policlorados - anĂĄlisis de fĂĄrmacos de orina, sangre, suero, plasma ingredientes /farmacĂŠĂşticos/activos de comprimidos, cremas Debido a la modificaciĂłn bifuncional el CHROMABONDfi Easy es considerablemente mĂĄs hidrofĂlico que los polĂmeros convencionales de poliestireno-divinilbenceno y por consiguiente fĂĄcilmente mojables con agua. El Easy effect: Muestras acuosas se pueden cargar directamente sin acondicionado previo! Esto significa que no se necesita acondicionamiento, en comparaciĂłn con los materiales de SPE estĂĄndar, donde las tasas de recuperaciĂłn normalmente disminuyen, en el peor caso hasta cero! Dependiendo de la tarea de separaciĂłn se puede requerir el acondicionamiento y se recomienda para el desarrollo del mĂŠtodo. Un efecto lateral positivo de la humectabilidad excelente: no existe descenso de los Ăndices de recuperaciĂłn, si el cartucho se mantiene seco, por tanto la automaciĂłn es mĂĄs fĂĄcil o en algunos casos - en comparaciĂłn con los materiales de sĂlice - solamente accesible con CHROMABONDfi EASY, porque se puede usar un vacĂo permanente sin supervisiĂłn. Otras ventajas de utilizar un material polimĂŠrico: - gran superficie, esto significa una capacidad de enlace muy buena (2-5 veces superior a los adsorbentes a base de sĂlice) - menos adsorbente es necesario en el cartucho (sin perder sensibilidad o recuperaciĂłn) - anĂĄlisis mĂĄs rĂĄpido, ya que se puede reducir la altura del lecho de adsorbente - disolventes ĂĄcidos o bĂĄsicos (por ejemplo, TFA) no destruyen la fase, o conducen a productos secundarios no previstos Debido a la modificaciĂłn polar el material es adecuado para una amplia gama de compuestos (ĂĄcidos, neutros, bĂĄsicos, polares y no polares). Tasas de recuperaciĂłn altamente reproducibles se podrĂĄn obtener incluso si el cartucho funciona en seco (especialmente ventajosas cuando se usan placas de 96 pocillos, donde no se dispone de llaves de cierre) Capacidad
ml 1 3 1 3 6 3 6 15 15 3 6
Capacidad
ud.E
mg 30 60 100 200 200 500 500 500 1000 200 200
30 30 30 30 30 30 30 20 20 250 250
CĂłdigo
4.003 4.003 4.003 6.226 6.234 4.003 6.224 4.003 4.003 4.003 4.003
719 721 720 452 375 728 850 726 727 723 724
BIGpacks: 4.003 723/4.003 724
'XH WR WKH ELIXQFWLRQDO PRGLÂż FDWLRQ &+520$%21'ÂŽ (DV\ LV FRQVLGHUDEO\ PRUH K\GURSKLOLF WKDQ FRQYHQWLRQDO SRO\VW\ UHQH GLYLQ\OEHQ]HQH SRO\PHUV DQG WKXV HDVLO\ ZHWWDEOH ZLWK ZDWHU The Easy effect: DTXHRXV VDPSOHV FDQ EH ORDGHG GLUHFWO\ ZLWKRXW SUHFRQ ditioning! 7KLV PHDQV WKDW OLWWOH RU HYHQ QR FRQGLWLRQLQJ LV QHHGHG LQ FRQWUDVW WR VWDQGDUG 63( PDWHULDOV ZKHUH UH FRYHU\ UDWHV QRUPDOO\ GHFUHDVH LQ WKH ZRUVW FDVH GRZQ WR ]HUR 'HSHQGLQJ RQ WKH VHSDUDWLRQ WDVN FRQGLWLRQLQJ PD\ EH UHTXLUHG DQG LV UHFRPPHQGHG IRU PHWKRG GHYHORSPHQW $ SRVLWLYH VLGH HIIHFW RI WKH H[FHOOHQW ZHWWDELOLW\ WKHUH LV QR GHFUHDVH RI UHFRYHU\ UDWHV LI WKH FDUWULGJH UXQV GU\ WKHUHIRUH DXWRPDWLRQ LV HDVLHU RU LQ VRPH FDVHV Âą FRP SDUHG WR VLOLFD PDWHULDOV Âą RQO\ IHDVLEOH ZLWK &+520$%21'ÂŽ (DV\ EHFDXVH D SHUPDQHQW YDFXXP FDQ EH XVHG ZLWKRXW VXSHUYLVLRQ
1188
Salvo error u omisiĂłn
)XUWKHU DGYDQWDJHV RI D SRO\PHULF PDWHULDO KLJK VXUIDFH WKLV PHDQV YHU\ KLJK ELQGLQJ FDSDFLW\ Âą WLPHV KLJKHU WKDQ VLOLFD EDVHG DGVRUEHQWV
OHVV DGVRUEHQW LV QHHGHG LQ WKH FDUWULGJH ZLWKRXW ORVLQJ VHQVLWLYLW\ RU UHFRYHU\
IDVWHU DQDO\VLV EHFDXVH WKH KHLJKW RI WKH DGVRUE HQW EHG FDQ EH UHGXFHG DFLGLF RU EDVLF VROYHQWV H J 7)$ GR QRW GHVWUR\ WKH SKDVH RU OHDG WR XQLQWHQGHG VLGH SURGXFWV %HFDXVH RI WKH SRODU PRGLÂż FDWLRQ WKH PDWHULDO LV VXLWDEOH IRU D EURDG UDQJH RI FRPSRXQGV DFLGLF QHXWUDO EDVLF SRODU DQG QRQSRODU VXEVWDQFHV +LJKO\ UHSURGXFLEOH UHFRYHU\ UDWHV DUH REWDLQHG HYHQ LI WKH FDUWULGJH UXQV GU\ HVSHFLDOO\ DGYDQWDJHRXV ZKHQ XVLQJ ZHOO SODWHV ZKHUH VWRSFRFNV DUH QRW DYDLODEOH
14. Cromatografía
GENERAL CATALOGUE 2010/11
Preparación de muestras/SPE 1 Chromabondfi C18 ec
1
octadecyl modified silica phase for SPE, endcapped
MACHEREY-NAGEL
base material silica, pore size 60Å, particle size 45µm for C18 ec, 100µm for C18 ec f (for fast flow), specific surface 500m²/g, pH stability 2 to 8 octadecyl phases, endcapped, carbon content 14% very non-polar, hydrophobic interactions with a wide variety of organic compounds advantageous for clean-up of samples with large structural variations (polarity differences) recommended applications: non-polar compounds aflatoxins, amphetamines, antibiotics, antiepileptics, barbiturates, caffeine, drugs, preservatives, fatty acids, nicotine, PAHs, pesticides, PCBs, heavy metals, vitamins very well suited for desalting of samples
Capacity
ml 1 3 3 6 6 6 15 45 70 3 6 6
Capacity
PK
mg 100 200 500 500 1000 2000 2000 5000 10000 500 500 1000
100 50 50 30 30 30 20 20 10 250 250 250
Cat. No.
4.003 4.003 4.003 4.003 4.003 6.701 4.003 4.003 4.003 4.003 4.003 4.003
442 444 448 451 454 243 603 604 560 446 450 452
BIGpacks: 4.003 446/4.003 450/4.003 452
2 Chromafixfi C18 ec
2 MACHEREY-NAGEL
Columns for C18 ec Size
S M L
Capacity
PK
Cat. No.
mg 270 530 950
50 50 50
4.003 839 4.003 840 4.003 841
Salvo error u omisión
1189
14. Cromatografía
GENERAL CATALOGUE 2010/11
Preparación de muestras/SPE 1
1 CHROMABONDfi C18 octadecyl modified silica phase for SPE, not endcapped
MACHEREY-NAGEL
base material silica, pore size 60Å, particle size 45µm for C18, 100µm for C18 f (for fast flow), specific surface 500m²/g, pH stability 2 to 8 octadecyl phases, not endcapped, carbon content 14% similar to C18 ec, however possesses more free silanols (SiOH), which allow secondary interactions with polar groups of the analytes recommended applications: non-polar compounds pesticides Capacity
Capacity
PK
mg 100 200 500 500 1000 2000 2000 5000 10000 500 500 1000
100 50 50 30 30 30 20 20 10 250 250 250
ml 1 3 3 6 6 6 15 45 70 3 6 6
2
6.226 9.003 4.003 4.003 4.003 4.003 4.003 6.700 4.003 4.003 4.003 4.003
798 487 434 436 438 512 464 747 561 433 435 437
2 CHROMAFIXfi C18 columns for C18 Size
S M L
3
Cat. No.
MACHEREY-NAGEL
Capacity
PK
Cat. No.
mg 270 530 950
50 50 50
7.083 665 7.079 617 4.003 838
3 Chromabondfi C18 Hydra octadecyl modified silica phase for SPE of polar analytes
MACHEREY-NAGEL
base material silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8 special octadecyl phase for polar analytes, not endcapped, carbon content 15% recommended applications: more polar compounds like pesticides and their polar degradation products, phenols, phenoxycarboxylic acids, nitroaromatics, pharmaceuticals
Capacity
ml 1 1 3 3 6 3 6 6 6
1190
Capacity
PK
mg 50 100 200 500 500 1000 1000 2000 3000
100 100 50 50 30 50 30 30 30
Salvo error u omisión
Cat. No.
4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003
565 566 567 569 573 571 575 576 577
14. Cromatografía
GENERAL CATALOGUE 2010/11
Preparación de muestras/SPE 1 Chromabondfi C8
1
octyl modified silica phase for SPE, not endcapped
MACHEREY-NAGEL
base material silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8 octyl phase, not endcapped, carbon content 8% similar to C18, however slightly more polar secondary interactions with polar compounds are more pronounced due to shorter alkyl chains recommended applications: pesticides, PCBs
Capacity
ml 1 3 3 6 6
Capacity
PK
mg 100 200 500 500 1000
100 50 50 30 30
Cat. No.
4.003 6.203 4.003 4.003 6.224
460 672 461 462 849
2 CHROMABONDfi C6H5
2
phenyl modified silica phase for SPE
MACHEREY-NAGEL
base material silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8 phenyl phase, carbon content 8% polarity similar to C8 in addition to hydrophobic interactions more selective adsorption is possible by Π-Π interactions due to the electron density of the phenyl ring recommended applications: aflatoxins caffeine phenols
Capacity
ml 1 3 3
Capacity
PK
Cat. No.
mg 100 200 500
100 50 50
4.003 491 4.003 608 6.224 848
3 Chromabondfi CN
3
cyanopropyl modified silica phase for SPE
MACHEREY-NAGEL
base material silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8 cyanopropyl phase, carbon content 5.5% polar to mid-polar in addition to weak hydrophobic interactions selective interactions are possible due to the high electron density of the CN group recommended application: cyclosporins carbohydrates Capacity
ml 1 3 3
Capacity
PK
Cat. No.
mg 100 200 500
100 50 50
4.003 473 4.003 611 4.003 474
Salvo error u omisión
1191
14. Cromatografía
GENERAL CATALOGUE 2010/11
Preparación de muestras/SPE 1
1 Chromabondfi NH2 aminopropyl modified silica phase for SPE
MACHEREY-NAGEL
base material silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8 aminopropyl phase, carbon content 3.5% polar, weak anion exchanger recommended applications: trace elements lipids Capacity
Capacity
PK
mg 100 200 500 500 1000 500
100 50 50 30 30 250
ml 1 3 3 6 6 3
Cat. No.
4.003 4.003 6.205 4.003 4.003 4.003
465 609 143 533 678 466
BIGpacks: 4.003 466
2
2 Chromabondfi OH diol modified silica phase for SPE
MACHEREY-NAGEL
Base material silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8 diol phase, carbon content 5.5% polar properties similar to SiOH recommended application: antibiotics prostaglandins Capacity
ml 1 3 3 6
3
Capacity
PK
mg 100 200 500 500
100 50 50 30
Cat. No.
4.003 4.003 4.003 6.224
470 610 471 847
3 Chromabondfi SiOH unmodified silica phase for SPE
MACHEREY-NAGEL
unmodified, weakly acidic silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8 very polar adsorbs humidity from air, for this reason it should be kept well closed and if necessary dried before use due to its high affinity for polar compounds it should not be conditioned with polar (e.g. methanol) or water-containing solvents recommended applications: aflatoxins chloramphenicol pesticides steroids vitamins
Capacity
ml 1 3 3 6 6 6 15 45 70 150 3 6 6
Capacity
PK
mg 100 200 500 500 1000 2000 2000 5000 10000 50000 500 1000 2000
100 50 50 30 30 30 20 20 10 10 250 250 250
BIGpacks: 4.003 477/4.003 482/4.003 499
1192
Salvo error u omisión
Cat. No.
4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 6.202 4.003 4.003 4.003 4.003
476 548 479 475 481 498 550 605 850 630 477 482 499
14. Cromatografía
GENERAL CATALOGUE 2010/11
Preparación de muestras/SPE 1 Chromabondfi Alox A/Alox N/Alox B
1
aluminium oxide, acidic, neutral, basic
MACHEREY-NAGEL
aluminium oxide, high purity, pore volume 0.90ml/g, particle size 60 to 150µm, specific surface 150m²/g acidic, pH 4 ±0.5 recommended application: together with phase SA for PCB and pesticides Alox A: acidic, pH 4 ±0.5 Alox N: neutral, pH 7 ±0.5 Alox B: basic, pH 9.5 ±0.5 Phase
Alox Alox Alox Alox Alox Alox Alox Alox Alox Alox Alox Alox
Capacity
Capacity
PK
ml 3 6 6 45 3 6 6 45 3 6 6 45
mg 500 500 1000 4000 500 500 1000 4000 500 500 1000 4000
50 30 30 20 50 30 30 20 50 30 30 20
A A A A N N N N B B B B
Cat. No.
4.003 4.003 4.003 4.003 4.003 4.003 4.003 6.226 4.003 4.003 4.003 4.003
621 622 456 623 619 620 515 917 615 628 458 629
2 Chromafixfi Alox
2
Columns for Alox Phase
Size
Alox N Alox N
M L
MACHEREY-NAGEL Capacity
PK
Cat. No.
mg 850 1700
50 50
4.003 853 4.003 854
3 Chromabondfi Florisilfi
3
magnesium silicate for SPE
MACHEREY-NAGEL
matrix magnesium silicate (MgO to SiOH 15:85), high purity, particle size 150 to 250µm recommended application: organic tin compounds, aliphatic carboxylic acids, PCBs, PAHs Capacity
ml 3 3 6 6 6 6
Capacity
PK
mg 200 500 500 1000 1000 1000
50 50 30 30 250 30
Cat. No.
4.003 4.003 4.003 6.224 4.003 4.003
624 488 557 842 489 490
BIGpacks: 4.003 489/4.003 490
Salvo error u omisión
1193
14. Cromatografía
GENERAL CATALOGUE 2010/11
Preparación de muestras/SPE 1
1 Chromabondfi PA polyamide 6 for SPE
MACHEREY-NAGEL
matrix polyamide 6, unmodified, high purity, particle size 40 to 80µm recommended application: flavonoids, PAHs Capacity
Capacity
PK
mg 200 500 500 1000
50 50 30 30
ml 3 3 6 6
2
Cat. No.
4.003 4.003 7.089 7.400
595 511 089 537
2 Chromabondfi PSA propylsulphonic acid modified silica cation exchanger for SPE
MACHEREY-NAGEL
Base material silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8 propylsulphonic acid modified silica very strong cation exchanger (capacity ~ 0.7meq/g) contrary to the SA phase no Π-Π interactions recommended applications: weak cations
Capacity
Capacity
PK
Cat. No.
mg 100 500 1000
100 50 30
4.003 626 4.003 627 6.206 233
ml 1 3 6
3
3 Chromabondfi SA benzenesulphonic acid modified silica cation exchanger for SPE (SCX)
MACHEREY-NAGEL
base material silica, pore size 60Å, particle size 45 µm, specific surface 500m²/g, pH stability 2 to 8 benzenesulphonic acid modified silica strongly acidic cation exchanger (capacity ~ 0.5meq/g) adsorbent with hydrophobic and Π-Π interactions (benzene ring) ion exchange of organic compounds from aqueous matrix elution of interesting compounds with solvent systems, which compensate the ionic and nonpolar interactions, e.g. methanolic HCl recommended application: amino acids amines chlorophyll PCBs
Capacity
Capacity
PK
mg 100 200 500 500 1000 500
100 50 50 30 30 250
ml 1 3 3 6 6 3 BIGpacks: 4.003 485
1194
Salvo error u omisión
Cat. No.
6.314 4.003 7.051 4.003 6.224 4.003
563 563 056 613 846 485
14. Cromatografía
GENERAL CATALOGUE 2010/11
Preparación de muestras/SPE 1 Chromabondfi SB
1
quaternary ammonium modified silica anion exchanger for SPE (SAX)
MACHEREY-NAGEL
base material silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8 silica modified with quaternary amine strongly basic anion exchanger (capacity ~ 0.3meq/g) not suited for very strong anions such as sulphonic acids, because these are difficult to elute recommended application: organic acids caffeine saccharin Capacity
Capacity
PK
mg 100 200 500 500 1000 500
100 50 50 30 30 250
ml 1 3 3 6 6 3
Cat. No.
4.003 4.003 7.075 4.003 6.206 4.003
486 580 759 614 234 487
BIGpacks: 4.003 487
2 Polymer-based ion exchangers for SPE
2
The innovative cation exchanger offers:
MACHEREY-NAGEL
mixed-mode SPE phase with distinct cation exchange and RP properties excellent enrichment of basic analytes modern support polymer with optimised pore structure and large specific surface good reproducibility, reliable and cost-efficient analyses more aggressive washing procedures for matrix removal possible cleaner samples and protection of analytical HPLC and GC instrumentation quantificationof analytes from heavily contaminated samples lower limits of detection also for critical matrices ... the perfect fit for basic analytes in comination with CHROMABOND® HR-X
3 Chromabondfi HR-XC
3
benzenesulphonic acid modified polymeric cation exchanger for SPE
MACHEREY-NAGEL
base material spherical PS/DVB copolymer, pore size 65 - 75Å, particle size 85µm, very large specific surface 800m²/g, pore volume 1.4cm³/g, pH stability 1 to 14 benzenesulphonic acid modification, exchange capacity 1.0meq/g RP capacity 300mg/g (caffeine in water) high-purity material, highest reproducibility and lowest blank values due to an optimised production process outstanding recovery rates especially for the enrichment of basic analytes recomended application: basic active ingredients from strongly matrix-contaminated samples e.g. urine, plasma, serum fungicides from food basic analytes, e.g. amines
Capacity
ml 3 3 6
Capacity
PK
Cat. No.
mg 200 500 500
30 30 30
4.003 821 4.003 822 4.003 823
Salvo error u omisión
1195
14. CromatografĂa
GENERAL CATALOGUE 2010/11
PreparaciĂłn de muestras/SPE Fractionation of acidic, neutral and basic analytes from serum Column type: CHROMABONDÂŽ HR-XC / 3 ml / 200 mg
3.500 mAU 3.000
100
serum sample without SPE
2.000 80
1.000
Further analysis IRU IUDFWLRQ $ +3/& H J RQ 18&/(2'85ÂŽ C18 *UDYLW\ IROORZLQJ 01 $SSO 1R IRU IUDFWLRQ % +3/& RQ 18&/(2'85ÂŽ C8 *UDYLW\ IROORZLQJ 01 $SSO 1R
60
after SPE with HR-XC
0
Recovery rates [%]
40
1
Fraction A: neutral and Fraction B: acidic analytes basic analytes
2
20
3
0
Compound
4
after SPE with HR-XC 0
5
10
15
min
MN Appl. No. 304780
1
Sample: PO VSLNHG PDWUL[ DFLGL¿ HG ZLWK —O +3PO4 Column conditioning: 5 ml methanol, then 5 ml water Sample application: VORZO\ SDVV PO VSLNHG VHUXP WKURXJK the column Washing: PO PRO O +&O Elution: PO PHWKDQRO fraction A: neutral and acidic analytes); then 5 ml methanol – NH3 Y Y fraction B: basic analytes)
Suprofen Naproxen Tolmetin Phenobarbital ,QGRPHWKDFLQ Hexobarbital
85 73 33
Compound 'R[HSLQ ,PLSUDPLQH 3. Amitriptyline 4. Trimipramine
HR-XC OasisŽ Strata¸ 0&; X-C 68 95 71 85 94 78 81
1 CHROMAFIXfi HR-XC Columns for HR-XC Size
S M L
1196
HR-XC
MACHEREY-NAGEL
Capacity
PK
Cat. No.
mg 155 240 500
50 50 50
4.003 835 4.003 836 4.003 837
Salvo error u omisiĂłn
14. Cromatografía
GENERAL CATALOGUE 2010/11
Preparación de muestras/SPE 1 Cromabond PS-RP/PS-OH-/PS-H+/PS-Mix/PS-Ag+/PS-Ba2+ phases for RP/ion chromatography
1 MACHEREY-NAGEL
base material: high-purity polystyrene-divinylbenzene copolymers (PS/DVB) pore size 100 Ä, paricle size 100 µm verly low degree of swelling, thus very well suited for chromatography reliable function over the whole pH range from 0-14 different modifications for different applications from elimination of nonpolar compounds up to removal of specific polar comonents recommended application: removal of interfering compounds - improves chromatographic separtions, if the interfering components overlap with the analyte in the chromatogram - improves lifetime of the chromatographic column, since interfering components can irreversibly block the column packing enrichment of the analytes
removal of organic interfering components from water removal or concentration of anions from water increasing the pH value in acidic samples removal or concentration of cations from water decreasing the pH value in basic samples desalting of water removal of halide ions from water removal of sulphate ions from water
PS-RP hydrophobic PS/DVB-copolymer PS-OH- strong PS/DVB anion exanger, OH- form capacity 0.6 meq/g PS-H+ strong PS/DVB cation exchanger, H+ form, capacity 2.9 meg/g PS-Mix mixture of PS-OH- and PS-H+ PS-AG+ strong PS/DVB cation exchanger, Ag+ form PS-Ba2+ strong PS/DVB cation exchanger, Ba2+ Form
Phase
Capacity
Capacity
PK
PS-OHPS-H+ PS-OHPS-H+ PS-OHPS-H+
ml 3 3 3 3 6 6
mg 200 200 500 500 500 500
30 30 30 30 30 30
Cat. No.
4.003 4.003 4.003 4.003 4.003 4.003
600 702 581 589 591 590
2 Chromafixfi PS
2
Columns for PS Phase
Size
PS-RP PS-OHPS-H+ PS-Ag+ PS-Ba2+ PS-RP PS-OHPS-H+ PS-Ag+ PS-Ba2+ PS-OH PS-H+
S S S S S M M M M M L L
MACHEREY-NAGEL Capacity
PK
mg 200 200 230 240 280 320 380 430 480 550 800 900
50 50 50 50 50 50 50 50 50 50 50 50
Salvo error u omisión
Cat. No.
4.003 4.003 4.003 4.003 4.003 6.228 4.003 7.401 4.003 7.402 4.003 4.003
869 867 866 865 868 258 861 474 864 218 862 863
1197
14. CromatografĂa
GENERAL CATALOGUE 2010/11
PreparaciĂłn de muestras/SPE 1
1 Chromabondfi Drug special silica phase for SPE enrichment of drugs from urine or plasma
MACHEREY-NAGEL
base material silica, pore size 60Å, particle size 45¾m, specific surface 500m²/g, pH stability 2 to 8 special bifunctional modification - C8/SA (strong cation exchanger - benzenesulphonic acid) recommended application: enrichment of acidic, neutral and basic drugs from urine or plasma
Capacity
Capacity
PK
mg 100 200 500 500
100 50 50 30
ml 1 3 3 6
2
Cat. No.
4.003 6.802 4.003 4.003
696 715 699 697
2 Chromabondfi Drug II Special silica phase for SPE of THC and derivatives acidic analytes from biological fluids (urine, blood ...)
MACHEREY-NAGEL
base material silica, pore size 60Å, particle size 45¾m, specific surface 500m²/g, pH stability 2 to 8 special bifunctional modification - C8/SB (strong anion exchanger - quaternary amine) recommended applications: extraction of THC and derivatives from urine, blood, serum, plasma acidic analytes from biological fluids
Capacity
Capacity
PK
mg 100 200 500 500
100 50 50 30
ml 1 3 3 6
3
Cat. No.
4.003 4.003 4.003 4.003
700 695 701 698
3 Chromabondfi NH2/C18 Combination phase for SPE analysis of PAHs from water containing humic acids
MACHEREY-NAGEL
Special combination phase: aminopropyl phase for removal of interfering humic acids octadecyl phase for enrichment of PAHs recommended application: PAHs from water containing humic acids
Capacity
ml 6 6
500 / 500 /
Capacity
PK
Cat. No.
mg 500 1000
30 30
6.228 257 4.003 675
PAHs from water containing humic acids Column type: Sample application: DVSLUDWH PO RI WKH SUHWUHDWHG CHROMABONDÂŽ NH & PO PJ J ZDWHU VDPSOH WKURXJK WKH FROXPQ a PO PLQ
glass column Washing: PO GLVW ZDWHU Âą SURSDQRO Y Y WKHQ Sample pretreatment: GU\ FROXPQ DERXW PLQ YDFXXP
PL[ PO ZDWHU VDPSOH ZLWK PO SURSDQRO Elution: [ PO &+ Cl SHUFRODWH Âż UVW PO LQWR Column conditioning: PO GLFKORURPHWKDQH PO WKH FROXPQ SDFNLQJ ZLWKRXW YDFXXP WKH DSSO\ OLJKW PHWKDQRO WKHQ PO GLVW ZDWHU Âą SURSDQRO YDFXXP LI QHFHVVDU\ HYDSRUDWH LQ D VWUHDP RI QLWURJHQ v/v) DQG Âż OO XS ZLWK D VXLWDEOH VROYHQW 01 $SSO 1R
1198
Salvo error u omisiĂłn
14. CromatografĂa
GENERAL CATALOGUE 2010/11
PreparaciĂłn de muestras/SPE 1 Chromabondfi CN/SiOH Combination phase for SPE analysis of PAH
1 MACHEREY-NAGEL
special combination phase cyanopropyl phase for selective adsorption of polycyclic aromatics via Î -Î interactions unmodified silica phase for removal of polar compounds recommended applications: extraction of the 16 PAHs according to EPA from soil samples Capacity
ml 3 6 6
Capacity
PK
Cat. No.
mg 1000 1000 1000
50 30 250
4.003 507 6.233 128 4.003 514
500 / 500 / 500 /
BIGpacks: 4.003 514
PAHs from soil Column type: Sample application: CHROMABONDÂŽ CN/SiOH, DVSLUDWH PO RI WKH H[WUDFW WKURXJK WKH FROXPQ 6 ml, 500/1000 mg Washing: PO SHWUROHXP HWKHU Elution: [ PO DFHWRQLWULOH WROXHQH Y Y WKHQ Sample pretreatment: GU\ J VRLO ZLWK VRGLXP VXO SKDWH DQG UHĂ€ X[ K ZLWK PO SHWUROHXP HWKHU LQ D HYDSRUDWH RU Âż OO WR WKH YROXPH UHTXLUHG Soxhlet extractor. For low PAH contents (colourless or )XUWKHU DQDO\VLV +3/& H J ZLWK FROXPQ [ PP weakly coloured extracts) concentrate extract to 1/10 NUCLEOSILÂŽ &18 PAH of its volume in a rotation evaporator. recovery rates see application 301310 at Column conditioning: PO SHWUROHXP HWKHU www.mn-net.com MN Appl. Nr. 301310
2 Chromabondfi Na2SO4/Florisilfi Combination phase for SPE of hydrocarbons from water acc. to DIN H53/ISO DIS 9377-4
2 MACHEREY-NAGEL
Special combination phase of sodium sulphate and Florisilfi recommended application: hydrocarbons from drinking, surface and waste waters Capacity
ml 6 6 6
Capacity
PK
Cat. No.
mg 2000 2000 2000
30 30 250
4.003 558 6.900 415 4.003 559
2000 / 2000 / 2000 /
BIGpacks: 4.003 559
Hydrocarbons from water Column type: $GG HQRXJK GLVW ZDWHU WR VHSDUDWH WKH RUJDQLF IURP CHROMABONDÂŽ Na2SO4/FlorisilÂŽ, WKH DTXHRXV SKDVH 2000/2000 mg, 6 ml glass column Column conditioning: PO SHWUROHXP HWKHU Internal standard solution: dissolve 20 mg n-tetraconSample application: tane (C40H82) in petroleum ether, add 20 ml n-decane slowly aspirate or force the sample through the column (C10H22 DQG Âż OO XS WR OLWUH ZLWK SHWUROHXP HWKHU )RU Elution: ZDVK ZLWK PO SHWUROHXP HWKHU (YDSRUDWH perparation of the extraction solution dilute standard the combined solutions from sample application and VROXWLRQ ZLWK SHWUROHXP HWKHU HOXWLRQ WR PO DW DERXW ƒ& ,I QHFHVVDU\ Âż OO XS WR Sample pretreatment: adjust 900 ml water (10 °C) with PO DJDLQ ,I WKH K\GURFDUERQ FRQWHQW LV KLJK HYDSR HCl (12 mol/l) to pH 2 and add 80 g MgSO4 $GG PO UDWLRQ WR PO PD\ QRW EH QHFHVVDU\
of the extraction solution, close the bottle and stir the Recovery rate: must be > 80 % for n WHWUDFRQWDQH 01 $SSO 1R VXVSHQVLRQ LQWHQVHO\ IRU PLQ
3 Chromabondfi SA/SiOH Combination phase for SPE analysis of PCBs
3 MACHEREY-NAGEL
Special combination phase: SA: strongly acidic cation exchanger based on silica with benzenesulphonic acid modification SiOH: unmodified silica for removal of polar compounds recommended application: extraction of PCBs from waste oil (hexane extract) Capacity
ml 3 3
Capacity
PK
Cat. No.
mg 500 500
50 250
6.901 798 4.003 513
500 / 500 /
BIGpacks: 4.003 513
1199
14. CromatografĂa
GENERAL CATALOGUE 2010/11
PreparaciĂłn de muestras/SPE
PCBs from waste oil Column type: CHROMABONDŽ SA/SiOH, 3 ml, 500/500 mg Column conditioning: 1 ml n-hexane Sample application: DSSO\ —O ZDVWH RLO WR WKH FROXPQ DQG DVSLUDWH RU force it into the adsorbent with 2 x 1 ml n-hexane 01 $SSO 1R
Elution: DVSLUDWH RU IRUFH DQRWKHU [ —O n-hexane through the column; collect all n-hexane fractions and if necessary adjust to a concentration suitable for subsequent analysis by either evaporting n-hexane in a stream of nitrogen or by dilution with n-hexane Recovery rates: 3&% 3&% 3&% 3&% 3&% 3&% 3&%
1 CHROMABONDfi SiOH-H+/SA
1
Combination phase for SPE analysis of PCBs
MACHEREY-NAGEL
SiOH-H+: H2SO4-impregnated silica phase for oxidation of accompanying compounds to ionic and/or polar compounds SA: strongly acidic cation exchanger based on silica with benzenesulphonic acid modification for removal of ionic and sulphur-containing compounds recommended application: extraction of PCBs from oil with reference to German industrial standard DIN 51527, part 1. This combination column is used together with a SiOH column.
Capacity
ml 3 3
Capacity
PK
Cat. No.
mg 500 500
50 250
7.051 054 4.003 492
500 500
BIGpacks: 4.003 492
CHROMABONDfi SiOH-H+/SA MACHEREY-NAGEL Description
PK
Cat. No.
Kombi-Kit for extraction of PCBs from oil with reference to DIN 51527, part 1, 25 columns each CHROMABONDfi SiOH-H+/SA and CHROMABONDfi SiOH
25
7.051 055
PCBs in oil samples (German industrial standard DIN 51527) Column type: Sample application: aspirate 500 ¾l sample through CHROMABONDŽ SiOH-H2SO4/SA 3 ml, 500/500 mg and the CHROMABONDŽ SiOH-H2SO4/SA column. Place CHROMABONDŽ SiOH / 3 ml / 500 mg CHROMABONDŽ SiOH-H2SO4/SA column on top of SiOH or Kombi-Kit PCB FROXPQ ZLWK DQ DGDSWRU DQG DIWHU DW OHDVW V À XVK Sample pretreatment: sample into the SiOH column with 2 x 1 ml n-hexane. extract oil-contaminated solids with n-hexane. Elution: elute SiOH column with 3 x 0.5 ml n-hexane; Homogenise other oil samples and dissolve 1.5 to 2.0 g adjust to a suitable concentration for subsequent GC in 50 ml n-hexane. Water which may cause turbidity analysis by evaporation of n-hexane in a stream of can be removed with sodium sulphate. nitrogen or by dilution with n-hexane Column conditioning: let 1 ml n KH[DQH À RZ WKURXJK Recovery rates: the CHROMABONDŽ SiOH-H2SO4/SA column PCB-28 99 %, PCB-52 95 %, PCB-101 99 %, PCB-138 MN Appl. No. 301380 94 %, PCB-153 99 %, PCB-180 96 %, PCB-209 101 %
1200
Salvo error u omisiĂłn
14. CromatografĂa
GENERAL CATALOGUE 2010/11
PreparaciĂłn de muestras/SPE 1 Chromabondfi NAN
1
Special phase for SPE analysis of PCB from sludge
MACHEREY-NAGEL
special combination phase: N: sodium sulphate for removal of trace water A: SiOH/AgNO3 phase for removal of sulphur, sulphur-containing and polar compounds recommended application: extraction of PCB from sludge Capacity ml 3 6 6
400 / 700 / 700 /
Capacity mg 1400 / 400 2000 / 700 2000 / 700
PK
Cat. No.
50 30 250
4.003 503 6.204 684 4.003 517
BIGpacks: 4.003 517
PCBs from sludge Compounds investigated: Column conditioning: PO n-hexane polychlorinated biphenyls (PCB) Sample application: This method is also suited for soil samples. aspirate 2 ml of the extract through the column Column type: Elution: VORZO\ DVSLUDWH PO n-hexane through the CHROMABONDÂŽ NAN, FROXPQ ZLWK OLJKW YDFXXP WKHQ HYDSRUDWH DQG Âż OO WR 6 ml, 700/2000/700 mg 5 ml with n-hexane Sample pretreatment: extract 2 g lyophilised sludge Recovery rates: with 70 ml n KH[DQH HYDSRUDWH H[WUDFW DQG Âż OO WR PO 3&% 3&% 3&% 3&% with n-hexane 3&% 3&% 3&% 01 $SSO 1R
Salvo error u omisiĂłn
1201
14. Cromatografía
GENERAL CATALOGUE 2010/11
Preparación de muestras/SPE 1
1
QuEChERS method and pre-mixes MACHEREY-NAGEL Within a fes years after its devleopment by Anastassiades et al. the QuEChERS method has gained a leading position for determination of pesticide residues in food by GC-MS or LC-MS allowing rapid and cheap clean-up of strongly matrix-contaminated samples. Standard clean-up of food samples 10 g sample are homogenised with 10 ml acetonitrile. After adding the internal standard the sample is shaken with 4 g MgSO4 and 1 g NaCI and afterwards centrifuged. 1 ml of the supernantant is spiked with 25 mg CHROMABOND® Diamino and 150 mg MgSO4 and shaken again. After centrifugation the supernatant is injected into the GC/MS. For optimising the extraction of pH-dependent compounds, for minimising decomposition of sensitive substances, and for broadending the matrix spectrum, different modifications of the QuEChERS method have been elaborated.
2 CHROMABONDfi
2
Además del CHROMABONDfi Diamino MACHEREY-NAGEL ofrece un número de tampones previamente mezclados y mezclas de extracción, que se determinan de forma especial en diferentes matrices de muestras.
MACHEREY-NAGEL
Método 1 para muestras de alimentos estándar: La muestra es extraida con Mix II y se puede purificar luego con Mix III o Mix IV (para alimentos con elevado contenido en grasas) Método 2 para alimentos complejos o ricos en grasas: La muestra es extraida con Mix I, luego purificada con - Mix III( muestras con bajo contenido en grasas) - Mix IV (contenido medio en clorofila y carotinoides; por ejemplo, ensalada) - Mix V (contenido elevado en clorofila y carotinoides; por ejemplo, paprica de verduras, espinacas) - Mix VI (contenido alto en grasas; por ejemplo, aguacate
Capacidad ml 15
Descripción Mix I Mezcla de extracción de citrato
15 15 15 15 15
Mix Mix Mix Mix Mix
3
II Mezcla de extracción de acetato III Mezcla de limpieza Diamino IV - Mezcla de limpieza Diamino/carbón V Mezcla de limpieza Diamino/Carbón VI Mezcla de limpieza Diamino/C 18 ec
ud.E
Código
4 g MgSO4, 1 g NaCl, 0,5 g Na2H-citrato*1,5 H2O, 1 g Na3-citrato*2H2O
50
4.003 824
6g 0,9 0,9 0,9 0,9
50 50 50 50 50
4.003 4.003 4.003 4.003 4.003
MgSO4 - 1,5 g acetato sódico g MgSO4 g MgSO4 - 0,015 g CHROMABOND Carbon g MgSO4 - 0,150 g CHROMABOND C 18 ec g MgSO4 - 0,045 g CHROMABOND Carbón
825 826 827 829 828
3 Chromabond® Diamino Special silica phase for determination of pesticides in food samples
MACHEREY-NAGEL
Base material silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8 Primary and Secondary Amine functions (PSA), 5% C removes polar compounds (e. g. organic acids, pigments, sugars) from matrices like fruit or vegetables similar phases: Supelclean PSA, Bond Elut PSA recommended application: special SPE phase for quick and cheap determination of pesticides in strongly matrix-contaminated samples by GC QuEChERS method = Quick Easy Cheap Effective Rugged Safe QuEChERS clean-up mixes containing 0.15 g Chromabond® Diamino each
Capacity
ml 3 6
1202
Capacity
PK
Cat No.
mg 200 500
50 30
4.003 652 4.003 653
Salvo error u omisión
14. Cromatografรญa
GENERAL CATALOGUE 2010/11
Preparaciรณn de muestras/SPE 1 Chromabondfi Diamino
1
Adsorbent
MACHEREY-NAGEL
Weight g 100 20
PK
Cat. No.
100 20
4.003 688 4.003 689
2
2 Chromabond QuEchERS fi
QuEChERS accessories
MACHEREY-NAGEL
Type
PK
Cat. No.
50 ml PP-centrifuge tube with crew cap
50
4.003 552
3 Manifold de vacรญo Chromabondfi y accesorios para manipular columnas y cartuchos de SPE Para la preparaciรณn simultรกnea de hasta 12, 16 รณ 24 muestras. Repuestos y accesorios para aplicaciones especiales
3
MACHEREY-NAGEL
Manifold de vacรญo completo que incluye: cabina de cristal con tapa y junta para la tapa, agujas desechables en la parte inferior de la tapa, indicador de vacรญo y vรกlvula de control de รฉste, tapones, vรกlvulas individuales y gradilla variable.
Descripciรณn
ud.E
Cรณdigo
Manifold de vacรญo completo para hasta 12 columnas o cartuchos de SPE (incluye depรณsito de reserva)
1
9.003 479
Manifold de vacรญo completo para hasta 16 columnas o cartuchos de SPE
1
4.003 586
Manifold de vacรญo completo para hasta 24 columnas o cartuchos de SPE
1
7.056 914
Tapa con junta para 12 columnas (incluye conexiones Luer y vรกlvulas), plรกstico
1
4.003 530
Juntas para tapa de 12 columnas Conexiones Luer para tapa, hembra Conexiones Luer para tapa, macho Vรกlvulas de plรกstico Agujas de acero inoxidable Accesorio de secado para 12 columnas Productos para la protecciรณn de contaminaciones cruzadas. Vรกlvulas cromadas, mate
2 12 12 12 12 1 1
6.801 4.003 4.003 7.089 7.079 4.003 4.003
Productos para la protecciรณn de contaminaciones cruzadas. Vรกlvula como anterior Productos para protecciรณn de contaminaciones cruzadas. Conectores de acero inoxidable
12 12
7.089 162 7.079 431
Productos para protecciรณn de contaminaciones cruzadas. Conectores de PTFE con vรกvula
12
6.234 376
4
6.900 713
Tubo adaptador para columnas de polipropileno de 1, 3 y 6ml (teflรณn, 1ml)
Protection from cross contamination
Drying attachment
)RU VSHFLDO DSSOLFDWLRQV ZKLFK UHTXLUH PD[LPXP SURWHF WLRQ IURP FURVV FRQWDPLQDWLRQ ZH VXSSO\ FKURPH SODWHG brass valves and stainless steel or PTFE connectors, the DSSOLFDWLRQ RI ZKLFK LV VKRZQ EHORZ 7KHVH VSHFLDO FRQ QHFWRUV DUH ยฟ WWHG WKURXJK WKH OLG WKXV WKH VDPSOH RQO\ has contact with the inert connector and not with the lid, GLUHFWO\ ร RZLQJ LQWR WKH UHFHSWDFOH
If the eluate has to be evaporated, this can be performed ZLWK WKH VR FDOOHG GU\LQJ DWWDFKPHQW 11 VHH EHORZ 7KLV VSHFLDO OLG KDV D JDV FRQQHFWRU RQ RQH VLGH 12), from ZKLFK WKH JDV LV IHG VLPXOWDQHRXVO\ WR WKH RU VWD tions (13 7KXV RU HOXDWHV FDQ EH HYDSRUDWHG VLPXO WDQHRXVO\ E\ MXVW FKDQJLQJ WKH OLG DQG DSSO\LQJ D VWUHDP RI LQHUW JDV H J QLWURJHQ
608 534 535 161 432 536 538
SPE column with frits and solid phase /XHU ยฟ WWLQJ IHPDOH lid of vacuum manifold with bore /XHU ยฟ WWLQJ PDOH connector stainless steel needle Salvo error u omisiรณn
1203
14. Cromatografía
GENERAL CATALOGUE 2010/11
Preparación de muestras/SPE Columnas vacías y accesorios para SPE CHROMABONDfi para empaquetamientos individuales de columnas de SPE con adsorbentes CHROMABONDfi Descripción
MACHEREY-NAGEL ud.E
Código
Columna de polipropileno vacía con elemento filtrante de PE, 3 ml
50
7.510 238
Columna de polipropileno vacía con elemento filtrante de PE, 6 ml
30
7.510 090
Columna de polipropileno vacía con elemento filtrante de PE, 15 ml
20
4.003 555
Columna de polipropileno vacía con elemento filtrante de PE, 45 ml
20
4.003 584
Columna de polipropileno vacía con elemento filtrante de PE, 30 ml
20
4.003 592
Columna de polipropileno vacía con elemento filtrante de PE, 70 ml
20
4.003 521
Columna de polipropileno vacía con elemento filtrante de PE, 150 ml
20
4.003 631
Columna de vidrio vacía con elemento filtrante de fibra de vidrio, 3 ml
50
4.003 528
Columna de vidrio vacía con elemento filtrante de fibra de vidrio, 6 ml
30
7.054 440
Elemento filtrante de fibra de vidrio para columna de vidrio de 3 ml Elemento filtrante de fibra de vidrio para columna de vidrio de 6 ml Adaptador (PP) para columnas de polipropileno (1, 3 y 6 ml) Columna de polipropileno, 70 ml, 1 adaptador
1
250 250 10 10
7.056 7.054 7.401 4.003
687 441 419 594
1 2 3 Chromabond® XTR For liquid-liquid extraction MACHEREY-NAGEL Base material coarse-grained kieselguhr (also known as diatomaceous earth, hydromatrix, celite) large pore size, high pore volume, constantly high batch-to-batch quality pH working range 1to13 application: liquid-liquid extraction of highly viscous aqueous solutions such as physiological fluids (blood, plasma, and serum) in clinical chemistry, dyes in textiles, environmental and food analysis without use of a separation funnel high water loadability without water breakthrough during elution with organic solvents also suited for removing small amounts of water from solvents which are not miscible with water.
2
advantages: fast, reproducible and economical simultaneous preparation of several samples no problems with phase separation, no formation of emulsions high recovery rates saving of time and solvents organic solutions need not to be dried after separation.
Capacity
3
ml 1 3 6 6 15 30 45 70 70 150
Capacity
g 0.25 1.50 1.00 1.00 3.00 4.50 8.30 14.50 14.50 37.50
max. volume capacity of aq. solution µl 0.25 0.50 1.00 1.00 3.00 5.00 10.00 20.00 20.00 50.00
BIGpacks: 4.003 637/4.003 648
1204
Salvo error u omisión
PK
100 50 30 250 30 30 30 30 100 10
Cat No.
4.003 4.003 4.003 4.003 4.003 6.205 4.003 6.225 4.003 4.003
645 646 636 637 638 372 647 180 648 650
14. Cromatografía
GENERAL CATALOGUE 2010/11
Preparación de muestras/SPE General column parameters CHROMABOND® XTR volume amount of adsorbent 1 ml 250 mg 3 ml 500 mg 6 ml 1g 15 ml 3g 30 ml 4.5 g 45 ml 8.3 g 70 ml 14.5 g 150 ml 37.5 g
max. volume capacity of aqueous sollution 0.25 ml 0.5 ml 1 ml 3 ml 5 ml 10 ml 20 ml 50 ml
Solvents applicable for elution waiting pe- elution riod before volume elution 5 min 5 min 5 – 10 min 5 – 10 min 5 – 10 min 10 – 15 min 10 – 15 min 10 – 15 min
3 ml 6 ml 8 ml 12 ml 16 ml 24 ml 40 ml 90 ml
diethyl ether tert-butyl methyl ether ethyl acetate n-hexane cyclohexane toluene dichloromethane (methylene chloride) trichloromethane (chloroform) trichloromethane / methanol (90:10, v/v) trichloromethane / methanol (85:15, v/v) diethyl ether / ethanol (90:10, v/v) diethyl ether / ethanol (80:20, v/v) dichloromethane / 2-propanol (90:10, v/v) dichloromethane / 2-propanol (85:15, v/v)
Adsorbente Chromabondfi XTR 50 bolsas de 14.5g (para preparar soluciones acuosas de 20ml max.)
MACHEREY-NAGEL
Descripción
ud.E
para columnas de PP con 100 elementos filtrantes de PE para NT20 con 50 elementos filtrantes de PE (10 mm diámetro) 500 g 1 kg 5 kg
50 50 500 1000 5000
Código 4.003 6.900 4.003 4.003 4.003
656 717 658 657 659
wirPodemos liefernsuministrar das gesamte Programm toda la
gama de productos des Herstellers de este fabricante!
Salvo error u omisión
1205
14. Cromatografía
GENERAL CATALOGUE 2010/11
Preparación de muestras/SPE
6\ULQJH ¿ OWHUV &+520$),/® Syringe ¿ OWHUV DUH XVHG IRU ¿ OWUDWLRQ RI VXVSHQGHG PDWWHU IURP OLTXLG VDP SOHV RU JDVHV :LWK CHROMAFIL® UDSLG SXUL¿ FDWLRQ DQG UHPRYDO RI SDUWL FOHV LV YHU\ VLPSOH MXVW SODFH WKH ¿ OWHU RQ WKH V\ULQJH DQG \RX DUH UHDG\ IRU ¿ OWUDWLRQ 6SHFLDO PDQLSXODWLRQV DUH QRW UHTXLUHG &RQWDPLQDWLRQ RI VHQ VLWLYH LQVWUXPHQWDWLRQ E\ VROLG LPSXULWLHV FDQ EH DYRLGHG WKXV LQFUHDVLQJ OLIHWLPH RI FKURPDWRJUDSKLF FROXPQV DQG HTXLSPHQW $GYDQWDJHV 3RO\SURS\OHQH KRXVLQJ FRQVLGHUDEO\ EHWWHU VROYHQW VWDELOLW\ FRPSDUHG WR DFU\ODWH DQG SRO\ VW\UHQH ¿ OWHUV ORZ FRQWHQW RI H[WUDFWDEOH VXEVWDQFHV +RXVLQJ XOWUDVRQLFDOO\ VHDOHG QRW JOXHG QR H[WUDFWDEOH FRPSRQHQWV IURP JOXHV 7KH VSHFLDO WKLFN ULP RI WKH KRXVLQJ LV LGHDO IRU XVH RI WKH ¿ OWHUV LQ ODERUDWRU\ URERWV H J %HQFKPDWH )LOWUDWLRQ LQ ERWK GLUHFWLRQV SRVVLEOH WKH OLTXLG FDQQRW E\SDVV WKH PHPEUDQH /XHU ORFN RQ VLGH RI HQWU\ VDIH FRQQHFWLRQ RQ WKH ´KLJK SUHVVXUH³ VLGH
6DPSOH FODUL¿ FDWLRQ
/XHU H[LW VWDQGDUG OXHU IRU PP ¿ OWHUV PLQLVSLNH OXHU ZLWK ORZ GHDG YROXPH DQG VPDOO 2' IRU PP ¿ OWHUV )LOWHU LQOHW DQG ¿ OWHU H[LW FDQ EH ¿ WWHG WR WKH &+520$%21'® FROXPQV IRU VHOHFWLYH VDPSOH SUHSDUDWLRQ ZLWK WKH DLG RI D VSHFLDO DGDSWRU 'HÀ HFWRU WKH VWUHDP RI OLTXLG LV EURNHQ DQG GLVWULEXWHG DQG GRHV QRW GLUHFWO\ KLW WKH PHPEUDQH WKLV SUHYHQWV UXSWXUH RI WKH PHPEUDQH
PP RU PP TXDOLW\ V\ULQJH ¿ OWHUV IRRG VDIH 3( ER[ ZLWK VFUHZ FDS HFRQRPLFDO SULFH
6WDU VKDSHG GLVWULEXWLRQ GHYLFH WKH OLTXLG LV HYHQO\ GLVWULEXWHG WR WKH ZKROH PHPEUDQH VXUIDFH WKLV UHVXOWV LQ D EHWWHU XWLOLVDWLRQ RI WKH WRWDO DUHD WKH ¿ OWHU LV QRW SOXJJHG XS UDSLGO\ KLJK À RZ HI¿ FLHQF\ &RORXU FRGHG ¿ OWHUV ¿ OWHUV ZLWK P SRUHV KDYH D \HOORZ XSSHU VKHOO WKDW RI ¿ OWHUV ZLWK P SRUHV LV FRORXUOHVV WKH GLIIHUHQW PHPEUDQH W\SHV DUH GLVWLQJXLVKHG E\ GLIIHUHQW FRORXUV RI WKH ORZHU VKHOO $YDLODEOH SRUH VL]HV DQG P H[FHSWLRQV 3(7 ¿ OWHUV ZLWK P JODVV ¿ EUH ¿ OWHUV ZLWK P 3(6 ¿ OWHUV ZLWK NjP )LOWHU VL]HV DQG PP GLDPHWHU 7KH VPDOO GLDPHWHU ¿ OWHUV DUH HVSHFLDOO\ UHFRPPHQGHG IRU YHU\ VPDOO VDPSOHV ZKLFK UHTXLUH H[WUHPHO\ ORZ GHDG YROXPHV O IRU PP O IRU PP $OO ¿ OWHUV FDQ EH DXWRFODYHG DW 121 °C DQG EDU IRU PLQ 5HFRPPHQGHG ¿ OWHU VL]H GHSHQGLQJ RQ VDPSOH YROXPH VDPSOH YROXPH ± PO ± PO
1206
CHROMAFIL® %,* %2;(6
UHFRPPHQGHG ¿ OWHU GLDPHWHU PP PP
'HSHQGLQJ RQ \RXU ¿ OWUDWLRQ WDVN \RX FDQ FKRRVH ¿ OWHU PHPEUDQHV PDGH IURP GLIIHUHQW PDWHULDOV 0DWHULDO 3RO\HVWHU 3(7 ZLWK RU ZLWKRXW JODVV ¿ EUH SUH¿ OWHU 5HJHQHUDWHG FHOOXORVH 5&
7HÀ RQ® 37)(
&HOOXORVH PL[HG HVWHUV 09
&HOOXORVH DFHWDWH &$ Â VWHULOH DQG QRQ VWHULOH 3RO\DPLGH 1\ORQ 3$
3RO\HWKHUVXOIRQH 3(6 Â VWHULOH 3RO\YLQ\OLGHQH GLÀ XRULGH 39') ZLWK RU ZLWKRXW JODVV ¿ EUH SUH¿ OWHU *ODVV ¿ EUH *)
Salvo error u omisión
14. Cromatografía
GENERAL CATALOGUE 2010/11
Preparación de muestras/SPE Syringe filters CHROMAFILfi CHROMAFIL® Xtra
MACHEREY-NAGEL
labelled for method validation and cerification Xtra: imprint for direct identification of membrane type, diameter and pore size Xtra: low bleeding polypropylene housing Xtra: colour-free plain polypropylene
Filtros de jeringa Chromafilfi PET con membrana de poliéster Membrana hidrofílica de uso general
MACHEREY-NAGEL
Para soluciones polares y no-polares. Filtro utilizado para HPLC, especialmente preparado para mezclas de agua y disolventes orgánicos; determinaciones para TOC/DOC. No utilizado para análisis citotóxicos; no inhibe el crecimiento de microorganismos y otras células. Filtro de poliéster con prefiltro de fibra de vidrio integrado (GF/PET): recomendado para soluciones con una gran carga de partículas o soluciones muy viscosas. Tipo
PET-20/25 PET- 45/25 PET-120/25 PET-20/25 PET- 45/25 PET-120/25 GF / PET- 20 / 25 GF / PET- 45 / 25 PET-45/15 MS GF / PET- 20 / 25 GF / PET- 45 / 25
Ø poro
Ø Membrana Color carcasa parte superior
µm 0.20 0.45 1.2 0.20 0.45 1.2
mm 25 25 25 25 25 25 25 25 15 15 25 25
1.0 / 0.45 0.20 0.45 1.0 / 0.20 1.0 / 0.45
marcado marcado marcado marcado marcado marcado azul negro amarillo incoloro azul negro
Color carcasa parte inferior
ud.E
100 100 100 400 400 400 100 100 800 800 400 400
naranja naranja naranja naranja naranja naranja
Código
4.003 6.232 6.232 4.003 4.003 6.233 9.049 9.049 4.003 4.003 9.049 9.049
417 548 549 418 416 172 079 080 397 398 020 021
MS = MiniSpike a la salida del filtro CHROMAFILfi Xtra: 4.003 417/6.232 548/6.232 549 BIG-BOX: 4.003 418/4.003 416/6.233 172/4.003 397/4.003 398/9.049 020/9.049 021
1 Filtros de jeringa CHROMAFILfi RC con membrana de celulosa regenerada Membrana hidrofílica con muy poca adsorción
1
MACHEREY-NAGEL
Para soluciones orgánicas y acuosas y muestras polares y medianamente polares. Capacidad de retención para proteinas 84ug/filtro Tipo
RC-20/25 RC-45/25 RC-20/25 RC-45/25 RC-15 / 15 MS RC-20/15 MS RC-45 / 15 MS RC-45/15 MS
Ø poro
µm 0,20 0,45 0,20 0,45 0,20 0,20 0,45 0,45
Ø Membrana Color carcasa parte superior mm 25 25 25 25 15 15 15 15
marcado marcado marcado marcado amarillo amarillo incoloro incoloro
Color carcasa parte inferior
ud.E
100 100 400 400 100 800 100 800
azul azul azul
Código
4.003 4.003 4.003 6.233 9.049 4.003 9.049 4.003
424 426 425 891 025 399 026 400
MS = MiniSpike a la salida del filtro BIG-BOX: 4.003 425/6.233 891/4.003 399/4.003 400
Salvo error u omisión
1207
14. Cromatografía
GENERAL CATALOGUE 2010/11
Preparación de muestras/SPE 1
1 Filtros de jeringa Chromafilfi PTFE con membrana de Teflonfi Membrana hidrofóbica.
MACHEREY-NAGEL
Para líquidos y gases no-polares. Muy resistente a todo tipo de disolventes, ácidos y bases. Pasando por la membrana alcohol, seguido de agua, se hace más hidrofóbica la membrana original. Tipo
Ø poro
Ø Membrana Color carcasa parte superior
µm 0,20 0,45 0,20 0,45 0,20 0,45 0,20 0,45 0,20 0,45
PTFE-20/25 PTFE-45/25 PTFE-20/25 PTFE-45/25 O- 20 / 3 O- 45 / 3 O- 20 / 15 MS O- 45 / 15 MS O-20/15 MS O-45/15 MS
mm 25 25 25 25 3 3 15 15 15 15
marcado marcado marcado marcado incoloro incoloro amarillo incoloro amarillo incoloro
Color carcasa parte inferior
incoloro incoloro incoloro incoloro incoloro incoloro incoloro incoloro
ud.E
100 100 400 400 100 100 100 100 800 800
Código
4.003 9.049 4.003 9.049 9.049 9.049 9.049 9.049 4.003 4.003
409 059 410 060 053 054 055 056 394 395
MS = MiniSpike a la salida del filtro BIG-BOX: 4.003 410/9.049 060/4.003 394/4.003 395
2
2 Mezcla de ésteres de celulosa (MV) Membrana hidrofílica
MACHEREY-NAGEL
Para soluciones acuosas y polares. Tipo
MV-20/25 MV-45/25 MV-20/25 MV-45/25
Ø poro
Ø Membrana Color carcasa parte superior
µm 0,20 0,45 0,20 0,45
mm 25 25 25 25
ud.E
marcado marcado marcado marcado
100 100 400 400
Código
4.003 4.003 4.003 4.003
407 405 408 406
BIG-BOX: 4.003 408/4.003 406
3
3 Acetato de celulosa (CA) Membrana hidrofílica
MACHEREY-NAGEL
Para filtraciones de aguas, polímeros solubles, especialmente preparado para macromoléculas biológicas. Muy alta estabilidad en soluciones acuosas. Extremadamente baja capacidad de retención de proteinas (21ug/filtro). También disponible en envase estéril (S) para filtraciones en condiciones de esterilidad (cada filtro envasado individualmente). Tipo
CA-20/25 CA-45/25 CA-20/25 CA-45/25 CA-20/25 S CA-45/25 S
Ø poro
µm 0,20 0,45 0,20 0,45 0,20 0,45
Ø Membrana Color carcasa parte superior mm 25 25 25 25 25 25
marcado marcado marcado marcado amarillo incoloro
BIG-BOX: 4.003 420/4.003 422
1208
Salvo error u omisión
Color carcasa parte inferior
rojo rojo
ud.E
100 100 400 400 50 50
Código
4.003 4.003 4.003 4.003 9.049 9.049
419 421 420 422 036 037
14. Cromatografía
GENERAL CATALOGUE 2010/11
Preparación de muestras/SPE 1 Poliamida (PA)/nylon
1
Membrana hidrofílica
MACHEREY-NAGEL
Para soluciones acuosas y orgánicas. Filtración de soluciones de muestras de polaridad media.
Tipo
PA-20/25 PA-45/25 PA-20/25 PA-45/25 AO-20/3 AO-45/3
Ø poro
Ø Membrana Color carcasa parte superior
µm 0,20 0,45 0,20 0,45 0,20 0,45
mm 25 25 25 25 3 3
Color carcasa parte inferior
marcado marcado marcado marcado crema crema
ud.E
100 100 400 400 100 100
crema crema
Código
4.003 6.232 4.003 6.234 9.049 9.049
411 389 412 011 047 048
BIG-BOX: 4.003 412/4.234 011
2 Polyethersulfone (PES)
2
hydrophilic membrane
MACHEREY-NAGEL
for aqueous and slightly organic liquids with higher flow rates very low adsorption for pharmaceuticals and proteins, with good stability against acids and bases for sterile filtration of non-sterile solutions we recommend the Chromafil Sterilizer PES (each filter individually sealed) binding capacity for proteins 29µg/filter Type
Pore size µm 0.20
Sterilizer PES - blue rim
Membrane dia. mm 25
PK
Cat. No.
50
6.228 095
3 Polivinilideno difluoruro (PVDF)
3
Membrana hidrofílica
MACHEREY-NAGEL
Para soluciones polares y no-polares, y polímeros solubles en agua Capacidad de retención para proteinas: 82 µg/filtro El filtro de PVDF con el prefiltro de fibra de vidrio integrado está recomendado para filtraciones de muestras biológicas con gran carga de partículas. Este filtro presenta una gran capacidad de retención para proteinas. También adecuado para filtraciones de soluciones polares y no-polares. Tipo
Ø poro
PVDF-20/25 PVDF-45/25 PVDF-20/25 PVDF-45/25 GF/P-45/25 GF/P-45/25
µm 0.20 0.45 0.20 0.45 1.0 / 0.45 1.0 / 0.45
Ø Membrana Color carcasa parte superior mm 25 25 25 25 25 25
marcado marcado marcado marcado negro negro
Color carcasa parte inferior
ud.E
100 100 400 400 400 100
blanco blanco
Código
4.003 9.049 4.003 4.003 4.003 4.003
413 063 414 415 402 401
CHROMAFILfi Xtra: 4.003 413/9.049 063/4.003 414/4.003 415 BIG-BOX: 4.003 414/4.003 402
Salvo error u omisión
1209
14. Cromatografía
GENERAL CATALOGUE 2010/11
Preparación de muestras/SPE 1 Fibra de vidrio (GF)
1
Filtro inerte. El tamaño de poro de 1um permite mayores flujos que los filtros con poro de filtro más pequeño.
MACHEREY-NAGEL
Para soluciones con gran carga de partículas o con alta viscosidad (muestras de suelos, caldos de cultivo) Como prefiltros para otros filtros Chromafil, previenen taponamientos de las membranas.
Tipo
Ø poro
GF- 100/25 GF- 100/25 GF- 100/15 MS
µm 1,0 nominal 1,0 nominal 1,0 nominal
Ø Membrana Color carcasa parte superior mm 25 marcado 25 marcado 15 azul
Color carcasa parte inferior
incoloro
ud.E
Código
100 400 100
6.232 362 4.003 423 9.049 077
MS = MiniSpike a la salida del filtro CHROMAFILfi Xtra: 6.232 362/4.003 423 BIG-BOX: 4.003 423
2
2 Placas filtrantes Chromabondfi Multi 96 Placas de polipropileno de 96 pocillos para la filtración simultánea de 96 muestras. Algunas de las ventajas de este sistema de alto rendimiento son: -
MACHEREY-NAGEL
resulta económico por el ahorro de tiempo y disolvente el uso de pipetas multicanal facilitan la operación preparado para adaptarse a los más comunes sistemas automáticos minimiza el volúmen muerto (≤40µl) los materiales de las membranas son los mismos que los de los filtros para jeringa Chromafilfi
Descripción
ud.E
Código
Placa para filtración con mezcla de ésteres de celulosa como elemento filtrante (0,20µm) Placa para filtración con mezcla de ésteres de celulosa como elemento filtrante (0,45µm)
1 1
4.003 976 4.003 977
Placa para filtración con mezcla de ésteres de celulosa como elemento filtrante (3,0µm)
1
4.003 978
Placa para filtración con celulosa regenerada (RC) como elemento filtrante (0,20µm)
1
4.003 971
Placa para filtración con celulosa regenerada (RC) como elemento filtrante (0,45µm)
1
6.227 345
Placa para filtración con PTFE como elemento filtrante (0,2µm)
1
6.227 343
Placa para filtración con PTFE como elemento filtrante (0,45µm)
1
6.227 344
Placa para filtración con PTFE como elemento filtrante (1,0µm)
1
4.003 974
Placa para filtración con PTFE como elemento filtrante (3,0µm)
1
4.003 975
Placa para filtración con PE como elemento filtrante (20µm)
1
4.003 970
Placa para filtración con PE como elemento filtrante (50µm)
1
4.003 973
Placa para filtración con fibra de vidrio (GF) como elemento filtrante (1µm)
1
6.227 346
Placa para filtración con fibra de vidrio (GF) como elemento filtrante (3µm)
1
4.003 972
Manifold de vacío para mono-bloques, con depósito, indicador y control de vacío. Requerido para filtración en placas de 96 pocillos
1
4.003 962
1210
Salvo error u omisión
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Preparación de muestras/SPE &KHPLFDO FRPSDWLELOLW\ RI ¿ OWHU PDWHULDOV The following table lists the chemical compatibility of our CHROMAFILŽ materials. The chemical compatibility depends on several parameters such as time, pressure, temperature and concentration. In most cases, CHROMAFILŽ ¿ OWHUV ZLOO KDYH RQO\ VKRUW FRQWDFW ZLWK D VROYHQW ,Q WKHVH FDVHV WKH\ PD\ EH XVHG GHVSLWH of limited compatibility. )RU H[DPSOH D 37)( ¿ OWHU ZLWK 33 KRXVLQJ GRHV QRW OLEHUDWH DQ\ 89 GHWHFWDEOH VXEVWDQFHV GXULQJ ¿ OWUDWLRQ RI PO 7+) although PP shows only limited resistance towards THF. Solvent Acetaldehyde Acetic acid, 100 % Acetone Acetonitrile $PPRQLD Benzene n–Butanol Cyclohexane 'LFKORURPHWKDQH 'LHWK\O HWKHU 'LPHWK\OIRUPDPLGH ¹'LR[DQH Ethanol Ethyl acetate Ethylene glycol Formic acid, 100 % Hydrochloric acid, 30 % Methanol 1LWULF DFLG Oxalic acid, 10 % aqueous Petroleum ether Phosphoric acid, 80 % Potassium hydroxide, 1 mol/l 2–Propanol Sodium hydroxide, 1 mol/l Tetrachloromethane Tetrahydrofuran Toluene Trichloroethene Trichloromethane 8UHD Water Xylene
09
CA
RC
Ňą Ňą Ňą Ňą Ňą
Ňą Ňą Ňą Ňą Ňą
Ň° Ňą Ň° Ň°
Ň°
Ň°
Ň°
PA
Material PTFE 39')
Ňą Ň° Ň° Ňą
Ň° Ň° Ň° Ň° Ň°
Ň°
Ň°
Ň° Ň° Ňą Ň° Ň°
PES
PET
GF
PP
Ň° Ň° Ň° Ň°
Ň° Ň° Ň° Ň° Ň°
Ň° Ň° Ň° Ň°
Ň°
Ň°
Ň° Ňą Ň° Ň°
Ň°
Ň°
Ň°
Ň°
Ň°
Ň°
Ň°
Ň°
Ň°
Ň° Ň°
Ň° Ňą
Ň° Ň° Ň°
Ňą Ň°
Ň° Ň° Ň°
Ň° Ň° Ň°
Ň° Ň° Ň°
Ň° Ň° Ň°
Ň° Ňą
Ňą
Ňą
Ňą Ňą Ňą
Ňą Ň° Ňą
Ň°
Ň°
Ňą
Ň° Ňą Ň° Ňą
Ň°
Ň°
Ň°
Ň° Ň° Ň°
Ň° Ň° Ň°
Ň° Ň° Ň°
Ň° Ň°
Ňą Ň° Ň°
Ň° Ň° Ň°
Ň° Ň° Ň°
Ň°
Ň°
Ň°
Ň°
Ň°
Ň°
Ň°
Ň°
Ň°
Ňą Ň° Ňą Ň° Ň°
Ňą Ňą Ň° Ňą Ňą Ň° Ňą
Ň° Ň° Ň°
Ň° Ň° Ň°
Ň° Ň° Ň°
Ňą Ň°
Ň° Ň° Ň°
Ň° Ň°
Ň°
Ň° Ň° Ň°
Ň° Ň° Ň° Ň° Ň° Ň° Ň°
Ň° Ň° Ň° Ňą Ň° Ň° Ň°
Ň° Ň° Ň°
Ň°
Ň° Ň°
Ň°
Ň° Ň°
Ň° Ň° Ň°
Ň°
Ň°
Ň°
Ň°
Ň°
Ň° Ňą Ňą Ňą Ň° Ň° Ňą
Ňą Ňą Ňą Ňą Ňą Ň° Ňą
Ňą Ň° Ňą
Ňą Ň° Ňą
Ň°
Ň° Ň° Ň°
Ň°
Ňą
Ň°
Ň°
Ňą
Ňą
Ň°
Ň°
Ňą
Ň°
Ň° Ň° Ň° Ň° Ň°
Ň° Ňą Ň° Ň° Ň°
Ň° Ň° Ň° Ň° Ň°
Ň°
Ň°
Ňą Ň°
Ň°
Ň°
Ň°
Ňą Ň° Ň° Ň°
Ň° Ň° Ň° Ň° Ň°
Ň° Ň° Ň° Ň°
Ňą Ň°
Ň°
Ň°
Ň° Ň° Ň° Ň° Ň°
Ň° Ň° Ň° Ň° Ň°
Ňą Ň° Ň°
'DWD QRW JXDUDQWHHG Ň° resistant, Ňą not resistant, limited resistance 09 FHOOXORVH PL[HG HVWHUV &$ FHOOXORVH DFHWDWH 5& UHJHQHUDWHG FHOOXORVH 3$ SRO\DPLGH 37)( SRO\WHWUDĂ€ XRURHWK\OHQH 7HĂ€ RQ 39') SRO\YLQ\OLGHQH GLĂ€ XRULGH 3(6 SRO\HWKHUVXOIRQH 3(7 SRO\HVWHU *) JODVV Âż EUH 33 SRO\SURS\OHQH KRXVLQJ PDWHULDO
Salvo error u omisiĂłn
1211
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/HPLC(alta resoluciĂłn)
NUCLEODURÂŽ high purity silica for HPLC
NUCLEODURŽ is a fully synthetical type B silica (silica of 3rd JHQHUDWLRQ Rӽ HULQJ KLJKO\ advanced physical properties like totally spherical particle shape, outstanding surface microstructure, high pressure stability and low metal content. NUCLEODURŽ as a state-of-the-art silica is the ideal base material for modern HPLC SKDVHV ,W LV WKH UHVXOW RI 0$&+(5(< 1$*(/¡V pioneering research in chromatography for PRUH WKDQ \HDUV DQG VXFFHHGV 01¡V IDPRXV NUCLEOSILŽ silica.
Columns for HPLC
,Q 53 OLTXLG FKURPDWRJUDSK\ WKH HÔ&#x20AC; FLHQF\ RI WKH SDFN LQJ LV VWURQJO\ DÓ˝ HFWHG E\ WKH TXDOLW\ RI WKH EDVH VLOL ca itself. Shortcomings in the surface geometry of the particles or metal contaminants are the main reasons for inadequate coverage with the covalently bonded alkylsilanes in the subsequent derivatization steps. It is well known, that poor surface coverage and, in consequence, high activity of residual free silanols often results in peak tailing or adsorption, particularly with basic compounds.
Particle shape and surface symmetry
Elementary analysis (metal ions) of NUCLEODURÂŽ 100-5 Aluminium Iron Sodium Calcium Titanium Zirconium Arsenic Mercury
< < < < < < < <
5 5 5 10 1 1 0.5 0.05
ppm ppm ppm ppm ppm ppm ppm ppm
Pressure stability The totally spherical and 100% synthetic silica gel exhibits an outstanding mechanical stability, even at KLJK SUHVVXUHV XS WR EDU DQG HOHYDWHG HOXHQW Óż RZ rates. In addition, after several cycles of repeated packing, no VLJQLÓž FDQW GURS LQ SUHVVXUH FDQ EH REVHUYHG 7KH ODW ter is of prime importance for preparative and processscale applications. Physical properties of NUCLEODURÂŽ Surface (BET) Pore size Pore volume
340 m2/g 110 Ă&#x2026; 0.9 ml/g
NUCLEODURÂŽ PRGLÓž FDWLRQV
NUCLEODURÂŽ silicas are synthesized in a unique and carefully controlled manufacturing process which provides silica particles, which are totally spherical. The picture shows the outstanding smoothness of the NUCLEODURÂŽ surface.
Purity As already mentioned above, a highly pure silica is required for achieving symmetric peak shapes and maximum resolution. Inclusions of e. g. iron or alkaline earth metal ions on the silica surface are largely responsible for the unwanted interactions with ionizable analytes, e. g. amines or phenolic compounds.
1212
NUCLEODURÂŽ is virtually free of metal impurities and low acidic surface silanols. Elemental analysis data of NUCLEODURÂŽ Ä&#x201A;P PHDVXUHG E\ $$6 DUH OLVWHG EHORZ
6HYHUDO GLÓ˝ HUHQW VXUIDFH PRGLÓž FDWLRQV EDVHG on NUCLEODURÂŽ silica have been developed over the last years providing a full range of VSHFLÓž HG +3/& SKDVHV DQG DQ LGHDO WRRO IRU every separation: NUCLEODURÂŽ C18 Gravity and C8 Gravity NUCLEODURÂŽ C18 Isis NUCLEODURÂŽ C18 Pyramid NUCLEODURÂŽ Sphinx RP NUCLEODURÂŽ CN and CN-RP NUCLEODURÂŽ NH2 and NH2-RP NUCLEODURÂŽ C18 ec and C8 ec For important properties of NUCLEODURÂŽ phases please see our summary.
Salvo error u omisiĂłn
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/HPLC(alta resolución)
Overview of NUCLEODUR® HPLC phases
&KDUDFWHULVWLFV
C18 Gravity
B
6WDELOLW\
RFWDGHF\O SKDVH, high GHQVLW\ FRDWLQJ PXOWL HQGFDSSLQJ
S+ VWDELOLW\ ² VXLWHG IRU /& 06
& Á 863 L1
C8 Gravity
RFW\O SKDVH KLJK GHQVLW\ FRDWLQJ PXOWL HQGFDSSLQJ
S+ VWDELOLW\ ² VXLWHG IRU /& 06
S+ VWDELOLW\ ² VXLWHG IRU /& 06
NUCLEODUR® (Si-O2)n
RFWDGHF\O SKDVH ZLWK VSHFLDOO\ FURVVOLQNHG VXUIDFH PRGLӾ FDWLRQ HQGFDSSLQJ
VWDEOH LQ DTXHRXV HOXHQWV ZLWKRXW SKDVH FROODSVH S+ VWDELOLW\ VXLWHG IRU /& 06
NUCLEODUR® (Si-O2)n
& Á 863 L7
C18 Isis
ELIXQFWLRQDO 53 SKDVH EDODQFHG UDWLR RI SURS\O SKHQ\O DQG &18 OLJDQGV HQGFDSSLQJ
S+ VWDELOLW\ VXLWHG IRU /& 06
NUCLEODUR® (Si-O2)n
& Á 863 L1
S+ VWDELOLW\ ²
& 863 L1 DQG L11
C18 ec
RFWDGHF\O SKDVH PHGLXP GHQVLW\ FRDWLQJ HQGFDSSLQJ & Á 863 L1
C8 ec
RFW\O SKDVH PHGLXP GHQVLW\ FRDWLQJ HQGFDSSLQJ
S+ VWDELOLW\ ²
CN / &1 53
NH2 / NH2 53
SiOH
F\DQR QLWULOH SKDVH IRU 13 DQG 53 VHSDUDWLRQV
²
& Á 863 L10
DPLQR SKDVH IRU 13 DQG 53 VHSDUDWLRQV
²
& Á 863 L8
XQPRGLӾ HG 863 L3
²
Q D
²
S+ VWDELOLW\ ² VXLWHG IRU PRELOH SKDVHV ZLWK KLJK FRQWHQWV RI ZDWHU
NUCLEODUR® (Si-O2)n
& Á 863 L7
S+ VWDELOLW\ ² VXLWHG IRU PRELOH SKDVHV ZLWK KLJK FRQWHQWV RI ZDWHU
NUCLEODUR® (Si-O2)n
Columns for HPLC
Sphinx RP
C18 PRGLӾ FDWLRQ ZLWK SRODU HQGFDSSLQJ
NUCLEODUR® (Si-O2)n
& Á 863 L1
C18 Pyramid
6WUXFWXUH
C NUCLEODUR® (Si-O2)n
A
NUCLEODUR® (Si-O2)n
6SHFLӾ FDWLRQ
NUCLEODUR® (Si-O2)n
Phase
S+ VWDELOLW\ ²
(Si-O2)n
OH OH
Si OH
Si O Si(CH ) 3 3
Si OH
Si O Si(CH ) 3 3 C N Si OH C N Si O Si(CH ) 3 3 NH2 Si OH NH2 Si OH
Si OH
$ K\GURSKRELF VHOHFWLYLW\ % SRODU LRQLF VHOHFWLYLW\ & VWHULF VHOHFWLYLW\
Salvo error u omisión
1213
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/HPLC(alta resoluciĂłn)
An optimised phase for every separations
$SSOLFDWLRQ
6LPLODU SKDVHV
LQ JHQHUDO FRP SRXQGV ZLWK LRQ L]DEOH IXQFWLRQDO JURXSV VXFK DV EDVLF SKDUPDFHXWL FDOV DQG SHVWLFLGHV
NUCLEOSILÂŽ C18 HD
OLNH &18 *UDYLW\ KRZHYHU JHQHUDOO\ VKRUWHU UHWHQWLRQ WLPHV IRU QRQSRODU FRPSRXQGV
6HSDUDWLRQ SULQFLSOH Ă 5HWHQWLRQ PHFKDQLVP
:DWHUV ;WHUUDÂŽ 5318 06 &18; 3KHQRPHQH[ /XQDÂŽ C18 (2), 6\QHUJLÂ&#x152; XQG 0D[ 53 =RUED[ÂŽ only hydrophobic ([WHQG & ,QHUWVLOÂŽ 2'6 ,,, 3XURVSKHUÂŽ 53 6WDU 53 interactions
NUCLEOSILÂŽ
C8 HD
N O
:DWHUV ;WHUUDÂŽ 538 06 &8; 3KHQRPHQH[ /XQDÂŽ C8; =RUED[ÂŽ (FOLSVH ;'% &
EDVLF SKDUPDFHX WLFDO LQJUHGLHQWV YHU\ SRODU FRP SRXQGV RUJDQLF DFLGV
hydrophobic interactions DQG polar interactions + ERQGV
3KHQRPHQH[ $TXDÂŽ; <0&ÂŽ AQ; :DWHUV $WODQWLVÂŽ G&
FRPSRXQGV ZLWK DURPDWLF DQG PXO QR VLPLODU SKDVHV WLSOH ERQG V\VWHPV
CH3
OH H H 3C
N O
Â&#x203A; Â&#x203A; LQWHUDFWLRQV DQG hydrophobic hydrophobic interactions
NO2
NUCLEOSILÂŽ C18 6SKHULVRUEÂŽ 2'6 ,, +\SHUVLOÂŽ 2'6 :DWHUV 6\PPHWU\ÂŽ C18; ,QHUWVLOÂŽ 2'6 ,, .URPDVLOÂŽ & /L&KURVSKHUÂŽ 53
NUCLEOSILÂŽ C8 ec / C8 ÂŽ ÂŽ UREXVW &8 SKDVH IRU 6SKHULVRUE & +\SHUVLO ÂŽ C8; 026 :DWHUV 6\PPHWU\ URXWLQH DQDO\VHV .URPDVLOÂŽ & /L&KURVSKHUÂŽ 53
NUCLEOSILÂŽ &1 &1 53
only hydrophobic interactions YDQ GHU :DDOV LQWHUDFWLRQV
VRPH UHVLGXDO VLODQRO LQWHUDFWLRQV
polar / ionic interactions, hydrophobic interactions
SRODU RUJDQLF FRP XQPRGLÓž HG 18&/(26,/ÂŽ SRXQGV LQ JHQHUDO
polar / ionic interactions
H3C
SiOH
C
Â&#x203A; Â&#x203A; LQWHUDFWLRQV, polar interactions + ERQGV hydrophobic interactions
VXJDUV VXJDU DOFR KROV DQG RWKHU K\ GUR[\ FRPSRXQGV NUCLEOSILÂŽ '1$ EDVHV SRODU NH2 / NH2 53 FRPSRXQGV LQ JHQHUDO
CH3
Si(CH3)3
N O
N
O C N +
H HO
NH3 OH H
O
SiOH
O2N
SKDVHV ZKLFK SURYLGH D VLPLODU VHOHFWLYLW\ EDVHG RQ FKHPLFDO DQG SK\VLFDO SURSHUWLHV
1214
Salvo error u omisiĂłn
Columns for HPLC
steric interactions DQG hydrophobic hydrophobic interactions
SRODU RUJDQLF FRPSRXQGV EDVLF GUXJV PROHFXOHV FRQWDLQLQJ Â&#x203A; HOHF WURQ V\VWHPV
H 3C
YDQ GHU :DDOV LQWHUDFWLRQV
KLJK VWHULF VHOHF WLYLW\ WKXV VXLWHG NUCLEOSILÂŽ C18 AB IRU VHSDUDWLRQ RI SRVLWLRQDO DQG ,QHUWVLOÂŽ 2'6 3 VWUXFWXUDO LVRPHUV <0&ÂŽ 3UR & 56 SODQDU QRQ SOD QDU PROHFXOHV
UREXVW &18 phase IRU URXWLQH DQDO\VHV
CH3
Si(CH3)3
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/HPLC(alta resoluciĂłn)
3DUWLFOH VL]H DQG VHSDUDWLRQ HÔ&#x20AC; FLHQF\
Â&#x2014;P SDUWLFOHV IRU LQFUHDVHG VHSDUDWLRQ HÔ&#x20AC; FLHQF\ decrease of analysis time (ultra fast HPLC) VKRUWHU FROXPQV ZLWK KLJK VHSDUDWLRQ HÔ&#x20AC; FLHQF\ VLJQLÓž FDQW LPSURYHPHQW RI UHVROXWLRQ LQFUHDVHG GHWHFWLRQ VHQVLWLYLW\ suitable for LC/MS due to low bleeding characteristics all NUCLEODURÂŽ SUHPLXP SKDVHV DUH DYDLODEOH LQ Â&#x2014;P C *UDYLW\ & *UDYLW\ & ,VLV & 3\UDPLG 6SKLQ[ 53 NUCLEODURÂŽ Â&#x2014;P SDUWLFOHV DUH IUDFWLRQDWHG WR OLPLW WKH LQFUHDVH LQ EDFN SUHVVXUH
1RZ DYDLODEOH Ä&#x201A;P SDUWLFOH VL]H
5HVROXWLRQ DV D IXQFWLRQ RI SDUWLFOH VL]H
)HDWXUHV RI Ä&#x201A;P 18&/(2'85ÂŽ VLOLFD SDUWLFOHV LQFUHDVH RI VHSDUDWLRQ HÔ&#x20AC; FLHQF\ E\ KLJKHU QXPEHU RI WKHRUHWLFDO SODWHV 1
Eluent: Flow rate: Pressure: Detection: Peaks: 1. Naphthalene 2. Ethylbenzene
VLJQLÓž FDQW LPSURYHPHQW LQ UHVROXWLRQ
Columns for HPLC
ORZ FROXPQ EDFN SUHVVXUH &RPSDULVRQ RI EDFN SUHVVXUH (OXHQW )ORZ UDWH 7HPSHUDWXUH &ROXPQ GLPHQVLRQ
PHWKDQRO PO PLQ Â&#x192;& [ PP
1
A) 3 Îźm Rs = 1.11
B) 1.8 Îźm Rs = 1.42 2
NUCLEODURÂŽ C *UDYLW\
Competitor A
EDU EDU
â&#x20AC;&#x201C; EDU
Ä&#x201A;P Ä&#x201A;P
50 x 4 mm NUCLEODURÂŽ C18 Gravity A) 3 Âľm, B) 1.8 Âľm acetonitrile â&#x20AC;&#x201C; water (80:20, v/v) 2 ml/min A) 80 bar, B) 160 bar UV, 254 nm
Column:
1
2
VKRUWHU UXQ WLPHV 0.4
0.6
0.4
0.6 min
5HGXFWLRQ RI DQDO\VLV WLPH Column: 50 x 4 mm (for 5 Âľm 125 x 4 mm) NUCLEODURÂŽ C18 Isis Eluent: 100 % methanol Flow rates and pressure see Ă&#x20AC; JXUH Detection: UV, 254 nm m-Terphenyl
1.8 Âľm, 3.00 ml/min (320 bar) o-Terphenyl
Triphenylene p-Terphenyl
1.8 Âľm, 2.00 ml/min (220 bar)
1.8 Âľm, 1.15 ml/min (125 bar) 5 Âľm, 0.8 ml min (50 bar) 0.0
0.5
1.0
1.5
2.0
2.5
3.0
Salvo error u omisiĂłn
3.5
4.0
min
1215
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/HPLC(alta resolución) HPLC columns with NUCLEODUR® Phasen NUCLEODUR® C18 - C 8 Gravity nonpolar high density phases
MACHEREY-NAGEL
available as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modifications Pore size 110 Ä; particle sizes 1.8 µm, 3 µm and 5 µm for C18, 1.8 and 5 µm for C8 7, 10, 12 and 16 µm particles for preparative separations on request carbon content 18 % C for C18 , 11 % C for C8 ideal for method development allows HPLC at pH extremes (pH 1 - 11) suitable for LC/MS due to low bleeding characteristics recommended for overall sophisticated analytical separations compound classes separated so far: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants; herbicides; phytopharmaceuticals; immunosppressants
Nucleodurfi C18 Gravity, 1,8µm Columnas analíticas EC. Tamaño de partícula 1,8µm, 18% C. Tipo
2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d.
MACHEREY-NAGEL
Longitud
ud.E
mm 30 30 30 30 50 50 50 50
1 1 1 1 1 1 1 1
Código
4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004
392 393 394 395 396 397 398 399
Nucleodurfi C18 Gravity, 3µm Columnas analíticas EC. Tamaño de partícula 3µm, 18% C. Tipo
2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4.6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4.6 mm i.d.
MACHEREY-NAGEL
Longitud
ud.E
mm 50 50 50 50 125 125 125 125 150 150 150 150 250 250 250 250
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Código
4.004 4.004 4.004 4.004 4.004 6.232 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004
400 401 402 403 404 333 405 406 411 412 413 414 407 408 409 410
Precolumnas para Nucleodurfi C18 Gravity, 3µm MACHEREY-NAGEL Tipo
2 y 3 mm i.d. 4 y 4,6 mm i.d.
1216
Salvo error u omisión
ud.E
Código
3 3
4.004 624 4.004 625
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/HPLC(alta resolución) Nucleodurfi C18 Gravity, 5µm Columnas analíticas EC. Tamaño de partícula 5µm, 18% C. Tipo
2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d.
MACHEREY-NAGEL
Longitud
ud.E
mm 50 50 50 50 125 125 125 125 150 150 150 150 250 250 250 250
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Código
4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 6.224 4.004
422 423 424 425 415 416 417 418 426 427 428 429 419 420 511 421
VarioPrep preparative columns NUCLEODURfi C18 Gravity particle size 5, 10 µm, 11 % C Type
10 mm ID 10 mm ID 10 mm i.d.
MACHEREY-NAGEL
Length
PK
Cat. No.
mm 50 250 10
1 1 2
4.004 773 4.004 775 4.004 780
*
Precolumnas para Nucleodurfi C18 Gravity, 5µm MACHEREY-NAGEL Tipo
2 y 3 mm i.d. 4 y 4,6 mm i.d.
ud.E
Código
3 3
7.510 912 4.004 626
Nucleodurfi C8 Gravity, 1.8µm Columnas analíticas EC. Tamaño de partícula 1.8 µm, 11% C. Tipo
2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d.
MACHEREY-NAGEL
Longitud
ud.E
mm 30 30 30 30 50 50 50 50
1 1 1 1 1 1 1 1
Salvo error u omisión
Código
4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004
563 564 565 566 559 560 561 562
1217
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/HPLC(alta resolución) Nucleodurfi C8 Gravity, 5µm Columnas analíticas EC. Tamaño de partícula 5µm, 11% C. Tipo
MACHEREY-NAGEL
Longitud
ud.E
mm 50 50 50 50 125 125 125 125 150 150 150 150 250 250 250 250
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d.
Código
4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004
543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558
Guard columns for Nucleodurfi C8 Gravity, 5 µm MACHEREY-NAGEL Type
2 and 3 mm i.d. 4 and 4.6 mm i.d.
PK
Cat. No.
3 3
4.004 719 4.004 720
VarioPrep preparative columns NUCLEODURfi C8 Gravity MACHEREY-NAGEL
particle size 5 µm, 11 % C Available on request.
1218
Salvo error u omisión
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/HPLC(alta resoluciĂłn) NUCLEODURfi C Isis phase with high steric selectivity C18 phase with special polymeric, crosslinked surface modification - USP L1 pore size 110 Ă&#x201E;, particle sizes 1.8 Âľm, 3 Âľm and 5 Âľm; 20 % C high steric selectivity outstanding surface deactivation suitable for LC/MS due low bleeding characteristics pH stability 1 - 10 broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitamins
MACHEREY-NAGEL
6XUIDFH PRGLÂż FDWLRQ %\ XVH RI VSHFLÂż F &18 silanes and appropriate polymeric bonding technologies a dense shield of alkyl chains protects the subjacent silica matrix. (OHPHQWDO DQDO\VLV RI 18&/(2'85ÂŽ C18 ,VLV VKRZV D FDUERQ ORDG RI The target crosslinking of the C18 chains on the surface enables the separation of compounds with similar molecular structure but different stereochemical properties. The technical term for this feature is steric selectivity. Steric selectivity of NUCLEODURÂŽ C18 Isis &ROXPQV [ PP NUCLEODURÂŽ C18 Isis, monomerically coated C18 phase, C18 phase with polar endcapping Eluent: methanol â&#x20AC;&#x201C; water (90:10, v/v) )ORZ UDWH PO PLQ WHPSHUDWXUH Â&#x192;& 'HWHFWLRQ 89 QP ,QMHFWLRQ YROXPH Â&#x2014;O Peaks: 2 1. o-Terphenyl m-Terphenyl 1 p-Terphenyl 4 7ULSKHQ\OHQH 3
The separation of o-terphenyl and triphenylene is a concrete example to evaluate the selectivity potential of a reversed phase column in terms of the different shape of two molecules. The phenyl rings of o-terphenyl are twisted out of plane while triphenylene has a planar geometry. 7KH VHSDUDWLRQ IDFWRU ÄŽ YDOXH LV D PHDVXUH IRU WKH VWHULF VHOHFWLYLW\ $V LV VKRZQ LQ WKH IROORZLQJ FKURPDWRJUDPV WKH ÄŽ YDOXH LV FRQVLGHUDEOH ODUJHU RQ 18&/(2'85ÂŽ C18 Isis compared to a conventional C18 column. Steric selectivity of NUCLEODURÂŽ C18 Isis &ROXPQV [ PP HOXHQW PHWKDQRO Âą ZDWHU Y Y
)ORZ UDWH PO PLQ WHPSHUDWXUH Â&#x192;& 'HWHFWLRQ 89 QP LQMHFWLRQ YROXPH Â&#x2014;O Peaks: 1. o 7HUSKHQ\O 7ULSKHQ\OHQH
1
1
2
2
C18, polar endcapping monomeric C18 C18 Isis 0
NUCLEODURÂŽ C18 Isis
monomerically 1 coated C18 phase
= 1.93
= 1.35 2
3
4
min
5
0
5
10
0
5
10 min
Nucleodurfi C18 Isis, 1.8Âľm Columnas analĂticas EC. TamaĂąo de partĂcula 1.8Âľm, 20% C. Tipo
3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d.
MACHEREY-NAGEL
Longitud
ud.E
mm 30 30 30 30 50 50 50 50 100
1 1 1 1 1 1 1 1 1
Salvo error u omisiĂłn
CĂłdigo
4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.006
501 502 503 504 497 498 499 500 019
1219
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/HPLC(alta resolución) Nucleodurfi C18 Isis, 3µm Columnas analíticas EC. Tamaño de partícula 3µm, 20% C. Tipo
2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d.
MACHEREY-NAGEL
Longitud
ud.E
mm 50 50 50 50 100 125 125 125 125 150 150 150 150 250 250 250 250
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Código
4.004 4.004 4.004 4.004 4.006 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004
481 482 483 484 020 485 486 487 488 489 490 491 492 493 494 495 496
Columnas preparativas VarioPrep Tamaño de partícula 10µm, 18% C. Tipo
40 mm i.d.
MACHEREY-NAGEL
Longitud
mm 250
ud.E
Código
1
4.004 782
Precolumnas para Nucleodur C18 Isis, 3µm fi
MACHEREY-NAGEL Tipo
2 y 3 mm i.d. 4 y 4,6 mm i.d.
ud.E
Código
3 3
4.004 629 4.004 630
Nucleodurfi C18 Isis, 5µm Columnas analíticas EC. Tamaño de partícula 5µm, 20% C. Tipo
2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d.
MACHEREY-NAGEL
Longitud
ud.E
mm 50 50 50 50 100 125 125 125 125 150 150 150 150 250 250 250 250
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Código
4.004 4.004 4.004 4.004 4.006 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004
505 506 507 508 021 509 510 511 512 513 514 515 516 517 518 519 520
Precolumnas para Nucleodurfi C18 Isis, 5µm MACHEREY-NAGEL Tipo
2 y 3 mm i.d. 4 y 4,6 mm i.d.
1220
Salvo error u omisión
ud.E
Código
3 3
4.004 640 4.004 641
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/HPLC(alta resoluciĂłn) Columnas preparativas VarioPrep NUCLEODURfi C18 Isis TamaĂąo de partĂcula 5Âľm, 20% C. Tipo
MACHEREY-NAGEL
Longitud
ud.E
CĂłdigo
mm 50 250
1 1
4.004 801 4.004 797
21 mm i.d. 10 mm i.d.
Columnas preparativas para HPLC C18 Isis, 3, 5Âľm MACHEREY-NAGEL Tipo
Longitud
ud.E
CĂłdigo
mm 10 20
2 2
4.004 802 4.004 803
8 mm i.d. 16 mm i.d.
Las precolumnas VarioPrep 10 x 8mm i.d. requieren el soporte de columna VP 8mm y se utilizan con columnas VarioPrep de 8 y 10mm i.d. Las precolumnas VarioPrep 20 x 16mm i.d. requieren el soporte de columna VP 16mm y se utilizan con columnas VarioPrep de 16 y 21mm i.d.
NUCLEODUR C18 Pyramid phase for highly aqueous eluents stabel in 100 % aqueous eluent systems- SUP L1 pore size 110 Ă&#x201E;, particle sizes 1.8 Âľm, 3 Âľm and 5 Âľm; 14 % C 7 and 10 Âľm particles for preparative separations on request interesting polar selectivity features excellent base deactivation; suitable for LC/MS due low bleeding characteristics pH stability 1 - 9
MACHEREY-NAGEL
classes of compounds separated so far: analgesics, penicillin antibiotics, nucleic acid bases, water-soluble vitamins, complexing agetns, organic acids
RP HPLC with highly aqueous eluents
'LIIHUHQW DSSURDFKHV FDQ EH XVHG WR LQFUHDVH FROXPQ VWD ELOLW\ ZLWK KLJKO\ DTXHRXV PRELOH SKDVH V\VWHPV 7KH PRVW SURPLVLQJ FRQFHSWV DUH LQFRUSRUDWLQJ D SRODU JURXS LQ WKH K\GURSKRELF DON\O FKDLQ RU XVLQJ K\GURSKLOLF HQGFDSSLQJ SURFHGXUHV WR LPSURYH WKH ZHWWDELOLW\ RI WKH UHYHUVHG SKDVH PRGLÂż FDWLRQ Stability features 18&/(2'85ÂŽ C18 3\UDPLG LV D VLOLFD SKDVH ZLWK K\GURSKLOLF HQGFDSSLQJ GHVLJQHG HVSHFLDOO\ IRU XVH LQ HOXHQW V\VWHPV RI XS WR ZDWHU 7KH VWDELOLW\ WHVW VKRZV WKH UHWHQWLRQ EHKDYLRXU RI WDUWDULF DFHWLF DQG PDOHLF DFLG XQGHU SXUHO\ DTXHRXV FRQGLWLRQV RQ 18&/(2'85ÂŽ C18 3\UDPLG LQ FRP SDULVRQ ZLWK D FRQYHQWLRQDOO\ ERQGHG 53 SKDVH ,W FDQ EH VKRZQ WKDW WKH UHWHQWLRQ WLPHV IRU 18&/(2'85ÂŽ C18 3\UDPLG UHPDLQ QHDUO\ XQFKDQJHG EHWZHHQ LQLWLDO LQ MHFWLRQ DQG UHVWDUW DIWHU WKH Ă&#x20AC; RZ KDV EHHQ VWRSSHG IRU KRXUV ZKLOVW WKH SHUIRUPDQFH RI WKH FRQYHQWLRQDO 53 FROXPQ FROODSVHG WRWDOO\ DIWHU PLQ Retention characteristics 7KH SRODU VXUIDFH GHULYDWL]DWLRQ H[KLELWV UHWHQWLRQ FKDUDF WHULVWLFV ZKLFK GLIIHUHQWLDWH WKH Âł3\UDPLG´ IURP FRQYHQ tional C18 VWDWLRQDU\ SKDVHV 7KH FKURPDWRJUDP DW ULJKW VKRZV WKH LPSURYHG UHWHQWLRQ EHKDYLRXU RI YHU\ SRODU FRPSRXQGV VXFK DV VKRUW FKDLQ RUJDQLF DFLGV ZKLFK DUH LQVXIÂż FLHQWO\ UHWDLQHG RQ 53 FROXPQV ZLWK SUHGRPLQDQWO\ K\GURSKRELF VXUIDFH SURSHUWLHV
Stability test initial injection UHVWDUW DIWHU K
Pyramid
3
3
1
1
stop
2
2
UHVWDUW DIWHU PLQ
3
FRQYHQWLRQDO &18
&RQYHQWLRQDO UHYHUVHG SKDVH FROXPQV RIWHQ GLVSOD\ VWD ELOLW\ SUREOHPV LQ HOXHQW V\VWHPV ZLWK KLJK SHUFHQWDJH RI ZDWHU ! DV HYLGHQFHG E\ D VXGGHQ GHFUHDVH RI UHWHQWLRQ WLPH DQG RYHUDOO SRRU UHSURGXFLELOLW\ 7KLV SKH QRPHQRQ LV GHVFULEHG DV SKDVH FROODSVH FDXVHG E\ WKH PRELOH SKDVH H[SHOOHG IURP WKH SRUHV GXH WR WKH IDFW WKDW K\GURSKRELF 53 SKDVHV DUH LQFRPSOHWHO\ ZHWWHG ZLWK WKH PRELOH SKDVH
1
stop
2
5 min
0
0
5 min
ERWK FROXPQV [ PP ,' P0 .+2324 S+ PO PLQ Â&#x192;& 89 QP LQMHFWLRQ YROXPH 1 Âľl Peaks: WDUWDULF DFLG DFHWLF DFLG PDOHLF DFLG 01 $SSO 1R
Separation of very polar compounds &ROXPQ [ PP 18&/(2'85ÂŽ C18 3\UDPLG Â&#x2014;P (OXHQW + 324 1 )ORZ UDWH PO PLQ 7HPSHUDWXUH Â&#x192;& 'HWHFWLRQ 89 QP 2 ,QMHFWLRQ YROXPH Â&#x2014;O Peaks: )RUPLF DFLG $FHWLF DFLG t0
01 $SSO 1R
Salvo error u omisiĂłn
0
2
min
1221
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/HPLC(alta resolución) Nucleodurfi C18 Pyramid, 1.8µm Columnas analíticas EC. Tamaño de partícula 1.8µm, 14% C. Tipo
2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d.
MACHEREY-NAGEL
Longitud
ud.E
mm 30 30 30 30 50 50 50 50
1 1 1 1 1 1 1 1
Código
4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004
473 474 475 476 477 478 479 480
Nucleodurfi C18 Pyramid, 3µm Columnas analíticas EC. Tamaño de partícula 3µm, 14% C. Tipo
2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d.
MACHEREY-NAGEL
Longitud
ud.E
mm 50 50 50 50 125 125 125 125 150 150 150 150 250 250 250 250
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Código
4.004 4.004 4.004 4.004 4.004 4.004 4.004 6.232 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004
469 470 471 472 458 459 460 796 461 462 463 464 465 466 467 468
Precolumnas para Nucleodurfi C18 Pyramid, 3µm MACHEREY-NAGEL Tipo
2 y 3 mm i.d. 4 y 4,6 mm i.d.
ud.E
Código
3 3
4.004 739 4.004 740
Nucleodurfi C18 Pyramid, 5µm Columnas analíticas EC. Tamaño de partícula 5µm, 14% C. Tipo
2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d.
1222
MACHEREY-NAGEL
Longitud
ud.E
mm 50 50 50 50 125 125 125 125 150 150 150 150 250 250 250 250
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Salvo error u omisión
Código
4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 6.226 4.004
443 444 445 446 447 448 449 450 454 455 456 457 451 452 913 453
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/HPLC(alta resolución) Precolumnas para Nucleodurfi C18 Pyramid, 5µm MACHEREY-NAGEL Tipo
2 y 3 mm i.d. 4 y 4,6 mm i.d.
ud.E
Código
3 3
4.004 721 4.004 722
Columnas preparativas VarioPrep NUCLEODURfi C18 Pyramid Tamaño de partícula 5µm, 14% C. Tipo
10 mm i.d. 21 mm i.d.
MACHEREY-NAGEL
Longitud
ud.E
Código
mm 250 250
1 1
4.004 783 4.004 785
VarioPrep columns for preparative HPLC C18 Pyramid, 3, 5µm MACHEREY-NAGEL Type
8 mm i.d. 16 mm i.d.
Longitud
PK
Cat. No.
mm 10 20
2 2
4.004 788 4.004 789
VarioPrep guard columns require the 8mm VP guard column holder and are suited for 8 and 10mm ID VP columns, 20 x 16mm ID VarioPrep guard columns require the 16mm VP guard column holder and are used for 16 and 21mm ID VP columns.
NUCLEODURfi Sphinx RP bifunctional RP phase distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11 MACHEREY-NAGEL pore size 110 Ä, particle sizes 1.8 µm, 3 µm and 5 µm; 14 % C high density of covalently bonded silanes for tailing-free peaks widens the scope for method development pH stability 1 - 10 suitable for LC/MS due low bleeding characteristics high reproducibility and consistent quality due to tight QC procedures range of application: quinolone antibiotics, sulfonamides, xanthines, substituted aromatics
Salvo error u omisión
1223
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/HPLC(alta resoluciĂłn) Alternative RP selectivity 18&/(2'85ÂŽ 6SKLQ[ 53 LV FKDUDFWHUL]HG E\ H[FHSWLRQDO selectivity features generated by a well-balanced ratio of FRYDOHQWO\ ERQGHG RFWDGHF\O DQG SKHQ\O JURXSV 7KH FRP bination of classical hydrophobic with Â&#x203A; Â&#x203A; interactions DURPDWLF ULQJ V\VWHP H[SDQGV WKH VFRSH RI VHOHFWLYLW\ LQ FRPSDULVRQ ZLWK FRQYHQWLRQDO UHYHUVHG SKDVH SDFNLQJV 18&/(2'85ÂŽ 6SKLQ[ 53 LV SDUWLFXODUO\ VXLWHG IRU WKH VHSDUDWLRQ RI PROHFXOHV FRQWDLQLQJ DURPDWLF DQG PXOWLSOH ERQGV )RU WKH VHSDUDWLRQ RI SRODU FRPSRXQGV 18&/(2 '85ÂŽ 6SKLQ[ 53 FDQ EH HVSHFLDOO\ UHFRPPHQGHG DQG FDQ DOVR RXWSHUIRUP PDQ\ FXVWRPDU\ & SKDVHV
,Q DGGLWLRQ H[KDXVWLYH HQGFDSSLQJ VWHSV PLQLPL]H XQ ZDQWHG VXUIDFH VLODQRO DFWLYLW\ DQG JXDUDQWHH H[FHOOHQW peak shapes even for strongly basic analytes 'LIIHUHQW IURP VWDQGDUG SKHQ\O SKDVHV 18&/(2'85ÂŽ 6SKLQ[ 53 LV IDU PRUH VWDEOH WRZDUGV K\GURO\VLV DQG LV DOVR VXJJHVWHG IRU /& 06 DSSOLFDWLRQV 'XH WR WKH DGGLWLRQDO LQWHUPROHFXODU LQWHUDFWLRQV 18&/(2 '85ÂŽ 6SKLQ[ 53 LV DQ LQWHUHVWLQJ UHSOHQLVKPHQW WR WKH KLJK GHQVLW\ ERQGHG SKDVHV 18&/(2'85ÂŽ & & Gravity DQG WKH SRODU HQGFDSSHG 18&/(2'85ÂŽ & 3\UDPLG
6HSDUDWLRQ RI Ă&#x20AC; DYRQRLGV RQ GLIIHUHQW 18&/(2'85ÂŽ phases &ROXPQV [ PP A) NUCLEODURÂŽ C8 Gravity, 5 Âľm B) NUCLEODURÂŽ C18 Gravity, 5 Âľm C) NUCLEODURÂŽ Sphinx RP, 5 Âľm (OXHQW ZDWHU Âą PHWKDQRO Y Y PO PLQ Â&#x192;& 'HWHFWLRQ 89 QP LQMHFWLRQ YROXPH Â&#x2014;O Peaks: &DWHFKLQ 5XWLQ )LVHWLQ 4XHUFHWLQ .DHPSIHURO ,VRUKDPQHWLQ
A
B
C 1
01 $SSO 1R
0.0
2
3 2.5
4
5 5.0
6 7.5 min
Nucleodurfi , Sphinx RP, 1.8Âľm Columnas analĂticas EC. TamaĂąo de partĂcula 1.8Âľm, 14% C. Tipo
2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d.
MACHEREY-NAGEL
Longitud
ud.E
mm 30 30 30 30 50 50 50 50
1 1 1 1 1 1 1 1
CĂłdigo
4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004
598 599 600 601 602 603 604 605
Nucleodurfi , Sphinx RP, 3Âľm Columnas analĂticas EC. TamaĂąo de partĂcula 3Âľm, 14% C. Tipo
2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d.
1224
MACHEREY-NAGEL
Longitud
ud.E
mm 50 50 50 50 125 125 125 125 150 150 150 150 250 250 250 250
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Salvo error u omisiĂłn
CĂłdigo
4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004
586 587 588 589 590 591 592 593 582 583 584 585 594 595 596 597
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/HPLC(alta resolución) Precolumnas para Nucleodurfi C18 SPHINX RP, 3µm MACHEREY-NAGEL Tipo
2 y 3 mm i.d. 4 y 4,6 mm i.d.
ud.E
Código
3 3
4.004 696 4.004 697
Nucleodurfi , Sphinx RP, 5µm Columnas analíticas EC. Tamaño de partícula 5µm, 14% C. Tipo
2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d.
MACHEREY-NAGEL
Longitud
ud.E
mm 50 50 50 50 125 125 125 125 150 150 150 150 250 250 250 250
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Código
4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 6.225 4.004 4.004 4.004 4.004 4.004
567 568 569 570 571 572 573 574 575 576 971 577 578 579 580 581
Precolumnas para Nucleodurfi C18 SPHINX RP, 5µm MACHEREY-NAGEL Tipo
2 y 3 mm i.d. 4 y 4,6 mm i.d.
ud.E
Código
3 3
4.004 681 4.004 682
Columnas preparativas VarioPrep NUCLEODURfi C18 SPHINX RP Tamaños de partícula 5µm, 14% C. Tipo
10 mm i.d. 10 mm i.d.
MACHEREY-NAGEL
Longitud
ud.E
Código
mm 50 250
1 1
4.004 790 4.004 791
Precolumnas para columnas preparativas VarioPrep SPHINX RP, 3, 5µm MACHEREY-NAGEL Tipo
8 mm i.d. 16 mm i.d.
Longitud
ud.E
Código
mm 10 20
2 2
4.004 795 4.004 796
Las precolumnas VarioPrep 10 x 8mm i.d. requieren el soporte de columna VP 8mm y se utilizan con columnas VarioPrep de 8 y 10mm i.d. Las precolumnas VarioPrep 20 x 16mm i.d. requieren el soporte de columna VP 16mm y se utilizan con columnas VarioPrep de 16 y 21mm i.d.
Salvo error u omisión
1225
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/HPLC(alta resoluciĂłn) NUCLEODURfi C18 ec - C8 ec nonpolar phases for routine analyses available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Ă&#x201E;, particle sizes, 3 Âľm and 5 Âľm; 7 Âľm, 10 Âľm, 12 Âľm, 16 Âľm, 20 Âľm, 30 Âľm und 50 Âľm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC pH stability 1 - 9 carbon content 17.5 % C for C18 , 10.5 % C for C8 high reproducibility from lot to lot for standard routine applications in reversed phase chromatography
NUCLEODURÂŽ C18 ec for daily routine analysis and up-scaling in preparative HPLC 7KH HIÂż FLHQF\ RI D VHSDUDWLRQ LV FRQWUROOHG E\ SDUWLFOH VL]H DQG VHOHFWLYLW\ RI WKH VWDWLRQDU\ SKDVH 7KH H[FHSWLRQDO VXUIDFH FRYHUDJH RI PRQRPHULF ERQGHG DON\OVLODQHV FRP ELQHG ZLWK DQ H[KDXVWLYH HQGFDSSLQJ UHVXOWV LQ D VXU IDFH ZLWK ORZHVW VLODQRO DFWLYLW\ 7KLV DOORZV WKH WDLOLQJ IUHH HOXWLRQ RI SRODU FRPSRXQGV VXFK DV EDVLF GUXJV 18&/(2'85ÂŽ C18 HF LV DOVR LGHDO IRU VFDOH XS SXUSRVHV Chemical stability 7KH XWPRVW SXULW\ RI WKH EDVH VLOLFD DQG WKH H[FHSWLRQDO VLODQH ERQGLQJ FKHPLVWU\ PLQLPL]HV WKH ULVN RI GLVVROXWLRQ RU K\GURO\VLV DW S+ H[WUHPHV
MACHEREY-NAGEL
Separation of phenols &ROXPQV [ PP 18&/(2'85ÂŽ C8 ec / C18 ec (OXHQW $ ZDWHU % PHWKDQRO *UDGLHQW IRU &8 PLQ % WKHQ WR % LQ PLQ JUDGLHQW IRU &18 PLQ % WKHQ WR % LQ PLQ )ORZ UDWH PO PLQ WHPSHUDWXUH Â&#x192;& 'HWHFWLRQ 89 QP LQMHFWLRQ YROXPH Â&#x2014;O Peaks: 5HVRUFLQRO 3\URFDWHFKRO 0HWKR[\SKHQRO 3KHQRO 0HWKR[\SKHQRO (WKR[\SKHQRO 9HUDWURO %LSKHQ\O RO 3KHQHWROH 7
High loadability /RDGDELOLW\ SUREDEO\ WKH PRVW LPSRUWDQW IHDWXUH IRU SUH SDUDWLYH /& LV GHWHUPLQHG E\ SRUH VL]H SRUH YROXPH DQG VXUIDFH DUHD RI WKH SDFNLQJ
6
1 5 7
2 3
1
NUCLEODURÂŽ octyl phases
8
6
9
4
%DVHG RQ WKH VDPH WRWDOO\ VSKHULFDO DQG KLJKO\ SXUH VLOLFD the C8 SKDVHV H[KLELW WKH VDPH H[FHOOHQW FKHPLFDO DQG PHFKDQLFDO VWDELOLW\ IHDWXUHV DV WKH &18 FRXQWHUSDUWV 'XH WR WKH VKRUWHU FKDLQ DQG OHVV K\GURSKRELF SURSHUWLHV RI WKH VWDWLRQDU\ SKDVH WKH UHWHQWLRQ RI QRQSRODU FRPSRXQGV LV GHFUHDVHG DQG LQ FRQVHTXHQFH D UHGXFWLRQ LQ WLPH RI DQDO\VLV FDQ EH DFKLHYHG 0RUHRYHU D VWURQJHU SRODU VHOHF WLYLW\ SDUWLFXODUO\ ZLWK WKH VHSDUDWLRQ RI LRQL]DEOH DQDO\WHV LV IUHTXHQWO\ REVHUYHG DV GLVWLQFW IURP WKH &18 SKDVHV
2
3
C8 ec 5
89
4
0
5
C18 ec
10
15
20
min
01 $SSO 1R
6RPH JHQHUDO SULQFLSOHV DUH
+LJK GHQVLW\ &8 and C18 SKDVHV DOORZ WDLOLQJ IUHH HOXWLRQ HYHQ IRU YHU\ SRODU FRPSRXQGV 2FW\O SKDVHV &8 VKRZ VXSHULRU SRODU VHOHFWLYLW\ 2FWDGHF\O SKDVHV &18 VKRZ VXSHULRU K\GURSKRELF VHOHFWLYLW\ +\GURSKRELF FRPSRXQGV VKRZ VKRUWHU UHWHQWLRQ WLPHV RQ &8 phases
Nucleodurfi 100-3 C18 ec Columnas analĂticas EC. Fase octadecilo 17.5%, tamaĂąo de partĂcula 3Âľm. Tipo
2 mm i.d. 3 mm i.d. 4 mm i.d. 4,6 mm i.d. 2 mm ID 3 mm ID 4 mm ID 4,6 mm ID 4,6 mm ID 2 mm ID 3 mm ID 4 mm ID 4,6 mm ID
1226
MACHEREY-NAGEL
Longitud
ud.E
mm 50 50 50 50 125 125 125 125 150 250 250 250 250
1 1 1 1 1 1 1 1 1 1 1 1 1
Salvo error u omisiĂłn
CĂłdigo
4.004 4.004 4.004 4.004 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003
375 376 377 378 796 797 798 799 800 801 802 803 804
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/HPLC(alta resolución) Guard columns for NUCLEODURfi 100-3 C18 ec MACHEREY-NAGEL Type
3 mm i.d. 4 mm i.d.
PK
Cat. No.
3 3
9.003 794 9.003 795
Nucleodurfi 100-5 C18 ec Columnas analíticas EC. Fase octadecilo 17.5%, tamaño de partícula 5µm. Tipo
2 mm ID 3 mm ID 4 mm ID 4,6 mm ID 2 mm ID 3 mm ID 4 mm ID 4,6 mm ID 4,6 mm ID 2 mm ID 3 mm ID 4 mm ID 4,6 mm ID
MACHEREY-NAGEL
Longitud
ud.E
mm 50 50 50 50 125 125 125 125 150 250 250 250 250
1 1 1 1 1 1 1 1 1 1 1 1 1
Código
4.004 4.004 4.004 4.004 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003
368 369 370 371 816 817 818 819 820 821 822 823 824
MACHEREY-NAGEL Type
3 mm i.d. 4 mm i.d.
PK
Cat. No.
3 3
9.003 814 9.003 815
Columnas preparativas VarioPrep NUCLEODURfi 100-5 C18 ec Fase octadecilo 17.5%, tamaño de partícula 5µm. Tipo
10 mm ID
MACHEREY-NAGEL
Longitud
ud.E
Código
mm 250
1
4.004 752
Columnas preparativas VarioPrep NUCLEODURfi 100-7 C18 ec Fase octadecilo 17.5%, tamaño de partícula 7µm. Tipo
10 mm ID 10 mm ID
MACHEREY-NAGEL
Longitud
ud.E
Código
mm 50 250
1 1
4.004 759 4.004 757
Columnas preparativas VarioPrep NUCLEODURfi 100-10 C18 ec Fase octadecilo 17.5%, tamaño de partícula 10µm. Tipo
10 mm ID 21 mm ID 10 mm ID
MACHEREY-NAGEL
Longitud
ud.E
Código
mm 50 50 250
1 1 1
4.004 749 4.004 751 4.004 745
Salvo error u omisión
1227
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/HPLC(alta resolución) Precolumnas para columnas preparativas VarioPrep 100-5, 100-7, 100-10, C18 ec MACHEREY-NAGEL Tipo
8 mm ID 16 mm ID
Longitud
ud.E
Código
mm 10 20
2 2
4.004 769 4.004 770
Las precolumnas VarioPrep 10 x 8mm i.d. requieren el soporte de columna VP 8mm y se utilizan con columnas VarioPrep de 8 y 10mm i.d. Las precolumnas VarioPrep 20 x 16mm i.d. requieren el soporte de columna VP 16mm y se utilizan con columnas VarioPrep de 16 y 21mm i.d.
Nucleodurfi 100-3 C8 ec Columnas analíticas EC. Fase octilo 10.5%, tamaño de partícula 3µm. Tipo
2 mm ID 3 mm ID 4 mm ID 4,6 mm ID 2 mm ID 3 mm ID 4 mm ID 4,6 mm ID 4,6 mm ID 2 mm ID 3 mm ID 4 mm ID 4,6 mm ID
MACHEREY-NAGEL
Longitud
ud.E
mm 50 50 50 50 125 125 125 125 150 250 250 250 250
1 1 1 1 1 1 1 1 1 1 1 1 1
Código
4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004
388 389 390 391 379 380 381 382 383 384 385 386 387
Precolumnas para Nucleodurfi 100-3 C8 ec MACHEREY-NAGEL Tipo
2 y 3 mm ID 4 y 4,6 mm ID
ud.E
Código
3 3
4.004 607 4.004 608
Nucleodurfi 100-5 C8 ec Columnas analíticas EC. Fase octilo 10.5%, tamaño de partícula 5µm. Tipo
2 mm ID 3 mm ID 4 mm ID 4,6 mm ID 2 mm ID 3 mm ID 4 mm ID 4,6 mm ID 4,6 mm ID 2 mm ID 3 mm ID 4 mm ID 4,6 mm ID
MACHEREY-NAGEL
Longitud
ud.E
mm 50 50 50 50 125 125 125 125 150 250 250 250 250
1 1 1 1 1 1 1 1 1 1 1 1 1
Código
4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 6.228
521 522 523 524 525 526 527 528 529 530 531 532 531
Precolumnas para Nucleodurfi 100-5 C8 ec MACHEREY-NAGEL Tipo
2 y 3 mm ID 4 y 4,6 mm ID
1228
Salvo error u omisión
ud.E
Código
3 3
4.004 708 4.004 709
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/HPLC(alta resoluciĂłn) Columnas preparativas VarioPrep Fase octilo 10.5%, tamaĂąo de partĂcula 5Âľm. Tipo
10 mm ID 10 mm ID
MACHEREY-NAGEL
Longitud
ud.E
CĂłdigo
mm 50 250
1 1
4.004 767 4.004 761
Columnas preparativas para HPLC VarioPrep 100-5 C8 ec MACHEREY-NAGEL Tipo
8 mm ID 16 mm ID
Longitud
ud.E
CĂłdigo
mm 10 20
2 2
4.004 771 4.004 772
Las precolumnas VarioPrep 10 x 8mm i.d. requieren el soporte de columna VP 8mm y se utilizan con columnas VarioPrep de 8 y 10mm i.d. Las precolumnas VarioPrep 20 x 16mm i.d. requieren el soporte de columna VP 16mm y se utilizan con columnas VarioPrep de 16 y 21mm i.d.
NUCLEODURfi CN/CN-RP cyano-modified high purity silica phase pore size 110 Ă&#x201E;, particle sizes 3 Âľm and 5 Âľm; 7 % C - USP L10 multi-mode columns (RP and NP) widens the scope in selectivity differnet retention characteristics compared to C8 and C18 stable against hydrolysis at low pH values, working range pH 1-8 high reproducibility from lot to lot classes of compounds separated so far: tricyclic antidepressants, steroids, organic acids
MACHEREY-NAGEL
6HSDUDWLRQ RI FROG PHGLFLQH LQJUHGLHQWV RQ WZR GLIIHUHQW 18&/(2'85ÂŽ SKDVHV &ROXPQV 4 A) 250 x 4 mm NUCLEODURÂŽ 100-5 C18 HF ÂŽ B) 250 x 4 mm NUCLEODUR 100-5 CN-RP (OXHQW DFHWRQLWULOH Âą P0 VRGLXP FLWUDWH 4 S+ Y Y
)ORZ UDWH PO PLQ WHPSHUDWXUH Â&#x192;& 'HWHFWLRQ 89 QP LQMHFWLRQ YROXPH Â&#x2014;O Peaks: 0DOHLF DFLG 3 2 5 1RUHSKHGULQH 3 5 (SKHGULQH 2 $FHWDPLQRSKHQ 1 6 &KORUSKHQLUDPLQH A %URPSKHQLUDPLQH B 1
01 $SSO 1R
0
6 4
8
12 min
Nucleodurfi 100-3 CN-RP Columnas analĂticas EC. Ciano fase reversa. TamaĂąo de partĂcula 3Âľm. Tipo
2 mm ID 3 mm ID 4 mm ID 4,6 mm ID
MACHEREY-NAGEL
Longitud
ud.E
mm 50 125 150 150
1 1 1 1
CĂłdigo
4.004 4.004 4.004 4.004
442 441 439 440
Precolumnas para NUCLEODURfi 100-3 CN-RP MACHEREY-NAGEL Tipo
2 y 3 mm ID 4 y 4,6 mm ID Salvo error u omisiĂłn
ud.E
CĂłdigo
3 3
4.004 663 4.004 664
1229
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/HPLC(alta resolución) Nucleodurfi 100-5 CN-RP Columnas analíticas EC. Ciano fase reversa. Tamaño de partícula 5µm. Tipo
4 mm ID 4,6 mm ID 4,6 mm ID 4 mm ID 4,6 mm ID
MACHEREY-NAGEL
Longitud
ud.E
mm 125 125 150 250 250
1 1 1 1 1
Código
4.004 4.004 4.004 4.004 4.004
436 437 438 434 435
Precolumnas para Nucleodurfi 100-5 CN-RP MACHEREY-NAGEL Tipo
4 y 4,6 mm ID
ud.E
Código
3
4.004 655
Nucleodurfi 100-5 CN Columnas analíticas EC. Ciano. Tamaño de partícula 5µm. Tipo
4 mm ID 4,6 mm ID 4 mm ID 4,6 mm ID
MACHEREY-NAGEL
Longitud
ud.E
mm 125 125 250 250
1 1 1 1
Código
4.004 4.004 4.004 4.004
432 433 430 431
Precolumnas para Nucleodurfi 100-5 CN MACHEREY-NAGEL Tipo
4 y 4,6 mm ID
ud.E
Código
3
4.004 654
Como precolumnas para las columnas EC se utilizan las precolumnas ChromCartfi con su adaptador EC. Las precolumnas en cartuchos ChromCartfi 8mm se presentan en paquetes de 3; las demás en paquetes de 1.
NUCLEODURfi NH2 /NH2 -RP amino-modified high purity silica phase pore size 110 Ä, particle sizes 5 µm; 2.5 % C; not endcapped - USP L8 multi-mode columns (RP and NP)
MACHEREY-NAGEL
normal phase chromatography (NP) with hexan, dichloromethane or 2-propanol as mobile phase for polar compounds such as substituted anilines, esters, chlorinated pesticides reversed phase chromatography (RP) of polar compounds like sugars in aqueous-organic eluent systems ion exchange chromatography of anions and organic acids using common buffers and organic modifiers stable against hydrolysis at low pH, working range pH 2-8, 100 % stable in water, suitable for LC-MS classes of compounds separated so far: polar compounds under RP conditions (sugars, DNA bases), hydrocarbons under NP conditions Eluent in column is n-heptane for the NP mode - RP columns are delivered in acetonitrile - water. For changing the solvent system a rinsing step with THF may be necessary.
1230
Salvo error u omisión
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/HPLC(alta resoluciĂłn)
&ROXPQ (OXHQW )ORZ UDWH 'HWHFWLRQ Peaks: )UXFWRVH *OXFRVH 6DFFKDURVH 0DOWRVH /DFWRVH
5HYHUVHG SKDVH VHSDUDWLRQ RI VXJDUV [ PP 18&/(2'85ÂŽ 1+2 53 1 DFHWRQLWULOH Âą ZDWHU Y Y
PO PLQ 5,
3
2
4
01 $SSO 1R
0
2
4
6
5
8
10 min
Nucleodurfi 100-5 NH2-RP Columnas analĂticas EC. Amino fase reversa. TamaĂąo de partĂcula 5Âľm. Tipo
4 mm ID 4,6 mm ID 4,6 mm ID 4 mm ID 4,6 mm ID
MACHEREY-NAGEL
Longitud
ud.E
mm 125 125 150 250 250
1 1 1 1 1
CĂłdigo
4.004 4.004 4.004 4.004 4.004
538 539 540 541 542
Precolumnas para Nucleodurfi 100-5 NH2-RP MACHEREY-NAGEL Tipo
4 y 4,6 mm ID
ud.E
CĂłdigo
3
4.004 628
Nucleodurfi 100-5 NH2 Columnas analĂticas EC. Amino. TamaĂąo de partĂcula 5Âľm. Tipo
4 mm ID 4,6 mm ID 4,6 mm ID 4 mm ID 4,6 mm ID
MACHEREY-NAGEL
Longitud
ud.E
mm 125 125 150 250 250
1 1 1 1 1
CĂłdigo
4.004 4.004 4.004 4.004 4.004
533 534 535 536 537
Precolumnas para Nucleodurfi 100-5 NH2 MACHEREY-NAGEL Tipo
4 y 4,6 mm ID
ud.E
CĂłdigo
3
4.004 627
Como precolumnas para las columnas EC se utilizan las precolumnas de cartucho ChromCartfi con su adaptador EC.
Unmodified NUCLEODURfi for normal phase separations totally spherical high purity silica - USP L3 pore size 110 Ă&#x201E;, pore volume 0.9 ml/g, surface (BET) 340 m2/g, density 0.47 g/ml, pressure stability 800 bar, pH stability 2 - 8 available particle sizes 3 Âľm and 5 Âľm; larger particles (10, 12, 16, 20 , 30 and 50 Âľm) for preparative applications are available as bulk materials
Salvo error u omisiĂłn
MACHEREY-NAGEL
1231
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/HPLC(alta resoluciĂłn) Nucleodurfi 100-5 Columnas analĂticas EC. TamaĂąo de partĂcula 5Âľm. Tipo
MACHEREY-NAGEL
Longitud
ud.E
CĂłdigo
mm 150 250 250
1 1 1
4.004 374 4.004 372 4.004 373
4,6 mm ID 4 mm ID 4,6 mm ID
Precolumnas para Nucleodurfi 100-5 MACHEREY-NAGEL Tipo
4 y 4,6 mm ID
ud.E
CĂłdigo
3
4.004 623
Columnas preparativas VarioPrep NUCLEODURfi 100-5 TamaĂąo de partĂcula 5Âľm. Tipo
10 mm ID
MACHEREY-NAGEL
Longitud
ud.E
CĂłdigo
mm 250
1
4.004 743
NUCLEOSILfi 100-5 C18 PAH special octadecyl phase for PAH analysis base material NUCLEOSILfi silica, particle size 5 Âľm, pore size 110 Ă&#x201E;; polymeric coating MACHEREY-NAGEL - USP L1 eluent in column acetonitrile/water 70:30 allows efficient gradient separation of the 16 PAH in accordance with EPA detection of the separated PAH by UV (250 to 280 nm), with diode array or with fluorescence detection at different wavelegths for excitation and emission (acenaphthylene cannot be analysed with fluorescence detection)
Rapid separation of 16 PAH according to EPA &ROXPQ [ PP 18&/(26,/ÂŽ 100-5 C 3$+ (OXHQWV $ ZDWHU % DFHWRQLWULOH *UDGLHQW IURP WR % LQ PLQ WKHQ PLQ DW % Âż QDOO\ LQ PLQ IURP WR % )ORZ UDWH PO PLQ SUHVVXUH Âą EDU 6 7HPSHUDWXUH Â&#x192;& 'HWHFWLRQ 89 QP 5 10 ,QMHFWLRQ YROXPH Â&#x2014;O 9 11 Peaks: 1DSKWKDOHQH $FHQDSKWK\OHQH $FHQDSKWKHQH )OXRUHQH 3KHQDQWUHQH $QWKUDFHQH )OXRUDQWKHQH 3\UHQH %HQ]>D@DQWKUDFHQH &KU\VHQH %HQ]R>E@Ă&#x20AC; XRUDQWKHQH %HQ]R>N@Ă&#x20AC; XRUDQWKHQH %HQ]R>D@S\UHQH 'LEHQ]>DK@DQWKUDFHQH %HQ]R>JKL@SHU\OHQH ,QGHQR> FG@S\UHQH
8 7 2 1
0
01 $SSO 1R
4
13 15 12 14
16
3
10 min
Nucleosilfi 100-5 C18 PAH Columnas analĂticas EC. Fase octadecilo PAH, tamaĂąo de partĂcula 5Âľm. Tipo
4 mm ID 3 mm ID 4 mm ID 2 mm ID 3 mm ID 4 mm ID 4,6 mm ID
1232
MACHEREY-NAGEL
Longitud
ud.E
mm 50 150 150 250 250 250 250
1 1 1 1 1 1 1 Salvo error u omisiĂłn
CĂłdigo
4.002 4.002 4.002 7.089 4.002 4.002 4.002
491 493 494 855 372 373 374
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/HPLC(alta resolución) Guard columns for NUCLEOSILfi 100-5 C18 PAH MACHEREY-NAGEL As guard columns for EC columns use ChromCartfi guard column cartridges with guard column adaptor EC.
1 HPLC columns for enantiomer separation
1
NUCLEOCEL ALPHA enantiomer separation based on amylose derivatives
MACHEREY-NAGEL
base material silica, chiral selector amylose-(3.5-dimethylphenylcarbamate) - USP L51 similar phases: Chiralpakfi AD, Kromasilfi , AmyCoatfi , Europak 01 high resolution type (S) with 5 µm particle size, allows use of shorter columns (150 mm) for faster separations, pressure stability up to ~ 150 bar (2000 psi) NUCLEOCEL ALPHA for normal phase applications: eluent in column n-heptane - propanol-2 (90:10, v/v) typical eluents are heptane - propanol mixtures NUCLEOCEL ALPHA-RP for reversed phase applications: eluent in column acetonitrile - water (50:50), v/v) designed for use either in polar organic mode or with eluents containing high concentrations of chaotropic salts such as perchlorate recommended application: pharmaceutically active compounds, chiral pollutants (e. g. herbicides, PCB), chiral compounds in food (dyes, preservatives), chiral catalysts and bioorganic compounds
Enantiomer separation of hexobarbital Column: 250 x 4.6 mm NUCLEOCEL ALPHA S Eluent: n-heptane – 2-propanol (80:20, v/v) Flow rate: 1 ml/min Temperature: 22 °C Detection: UV, 210 nm Injection volume: 5 µl Concentration: 1 µg/µl
ƴ = 1.39 Rs = 3.78
O
N
CH3
NH O
0
MN Appl. No. 121940
CH3 O
5
10
15 min
Nucleocel ALPHA S Columnas analíticas EC. Eluyente en columna n-heptano, 2-propanol. Tamaño de partícula 5 µm. Tipo
4,6 mm ID 4,6 mm ID
MACHEREY-NAGEL
Longitud
ud.E
Código
mm 150 250
1 1
4.002 477 4.002 478
Precolumnas para Nucleocel ALPHA S MACHEREY-NAGEL Tipo
4,6 mm ID
ud.E
Código
1
4.002 509
Nucleocel ALPHA-RP S Columnas analíticas EC. Eluyente en columna acetonitrilo, agua. Tamaño de partícula 5µm. Tipo
4,6 mm ID 4,6 mm ID
MACHEREY-NAGEL
Longitud
ud.E
Código
mm 150 250
1 1
4.002 479 4.002 480
Salvo error u omisión
1233
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/HPLC(alta resolución) Precolumnas para Nucleocel ALPHA-RP S, 5 µm MACHEREY-NAGEL Tipo
ud.E
Código
1
4.002 510
4,6 mm ID Como precolumnas para las columnas EC se utilizan las precolumnas de cartucho ChromCartfi con su adaptador EC. Las precolumnas de cartucho ChromCartfi 8mm vienen en paquetes de 3, todas las demás vienen en paquetes de 1 columna.
1
1 HPLC columns for enantiomer separation NUCLEOCEL DELTA enantiomer separation based on cellulose derivatives
MACHEREY-NAGEL
base material silica, chiral selector Cellulosetris-(3.5-dimethylphenylcarbamate) - USP L40 similar phases: Chiralcelfi OD, Kromasilfi , CelluCoat™, Eurocelfi 01 standard particle size 10 µm, high resolution type (S) with 5 µm particle size, allows use of shorter columns (150 mm) for faster separations, pressure stability up to ~ 150 bar (2000 psi) NUCLEOCEL DELTA for normal phase applications: eluent in column n-heptane - propanol-2 (90:10, v/v) typical eluents are heptane - propanol mixtures NUCLEOCEL DELTA-RP for reversed phase applications: eluent in column acetonitrile - water (40:60), v/v) designed for use either in polar organic mode or with eluents containing high concentrations of chaotropic salts such as perchlorate recommended applications: pharmaceutically active compounds, chiral pollutants (e. g. herbicides, PCB), chiral compounds in food (dyes, preservatives), chiral catalysts and bioorganic compounds
(QDQWLRPHU VHSDUDWLRQ RI À DYDQRQH Column: 250 x 4.6 mm NUCLEOCEL DELTA Eluent: n-heptane – 2-propanol (90:10, v/v) Flow rate: 1 ml/min Temperature: 25 °C Detection: UV, 254 nm Injection volume: 5 µl &RQFHQWUDWLRQ J O
ƴ = 1.29 Rs = 2.6 O
O
0
MN Appl. No. 121260
10
min
Nucleocel DELTA S Columnas analíticas EC. Eluyente en columna n-heptano, 2-propanol. Tamaño de partícula 5µm. Tipo
4,6 mm ID 4,6 mm ID
MACHEREY-NAGEL
Longitud
ud.E
Código
mm 150 250
1 1
4.002 446 4.002 445
Precolumnas para Nucleocel DELTA S MACHEREY-NAGEL Tipo
4,6 mm ID
1234
Salvo error u omisión
ud.E
Código
1
4.002 511
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/HPLC(alta resolución) Nucleocel DELTA Columnas analíticas EC. Eluyente en columna n-heptano, 2-propanol. Tamaño de partícula 10µm. Tipo
MACHEREY-NAGEL
Longitud
ud.E
Código
mm 250
1
4.002 444
4,6 mm ID
Precolumnas para Nucleocel DELTA MACHEREY-NAGEL Tipo
4,6 mm ID
ud.E
Código
1
4.002 513
Nucleocel DELTA-RP S Columnas analíticas EC. Eluyente en columna acetonitrilo, agua. Tamaño de partícula 5µm. Tipo
MACHEREY-NAGEL
Longitud
ud.E
Código
mm 150 250
1 1
4.002 449 4.002 448
4,6 mm ID 4,6 mm ID
Precolumnas para Nucleocel DELTA-RP S MACHEREY-NAGEL Tipo
4,6 mm ID
ud.E
Código
1
4.002 512
Nucleocel DELTA-RP Columnas analíticas EC. Eluyente en columna acetonitrilo, agua. Tamaño de partícula 10µm. Tipo
4,6 mm ID
MACHEREY-NAGEL
Longitud
ud.E
Código
mm 250
1
4.002 447
Guard columns for Nucleocel DELTA-RP MACHEREY-NAGEL Type
4.6 mm i.d.
Salvo error u omisión
PK
Cat. No.
1
4.002 514
1235
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/HPLC(alta resoluciĂłn) NUCLEOGELÂŽ SUGAR 810 separation of sugars MACHEREY-NAGEL
sulphonated polystyrene/divinylbenzene resins in diffent ionic forms and RP chromatography separation mechanism includes ion exclusion, ion exchange, size exclusion, ligand exchange as well as NP and RP chromatography H+ form: separation of sugars, sugar alcohols and organic acids - USP L17 - eluent in column 0.01 N H2SO4 Ca2+ form: separation of mono-, di- and oligosaccharides - USP L19 eluent in column water
6XJDUV DQG VXJDU DOFRKROV &ROXPQ [ PP 18&/(2*(/ÂŽ 68*$5 &D (OXHQW ZDWHU Ă&#x20AC; RZ UDWH PO PLQ GHWHFWLRQ 5,
2UJDQLF DFLGV DQG DOFRKROV [ PP 18&/(2*(/Ž 68*$5 + Injection volume: 5 ¾l (OXHQW PPRO +2624 )ORZ UDWH PO PLQ Temperature: 35 °C 'HWHFWLRQ 5,
&ROXPQ
0DOWRWULRVH 5DIÂż QRVH Cellobiose Trehalose 0DOWRVH 6XFURVH Lactose Palatinose 0HOLELRVH Lactulose *OXFRVH *DODFWRVH Xylose 6RUERVH Lactitol 0DOWLWRO 0DQQRVH 5KDPQRVH Palatitol )UXFWRVH $UDELQRVH meso (U\WKULWRO 0DQQLWRO $UDELWRO Xylitol 6RUELWRO 5LERVH
2[DOLF DFLG Citric acid 2URWLF DFLG 0DOHLF DFLG Tartaric acid Pyruvic acid 0DOLF DFLG 6XFFLQLF DFLG Lactic acid )RUPLF DFLG $FHWLF DFLG )XPDULF DFLG 0HWKDQRO Propionic acid 3\URJOXWDPLF DFLG (WKDQRO i %XW\ULF DFLG %XW\ULF DFLG 0
5
10 15 5HWHQWLRQ WLPH >PLQ@
20
25
01 $SSO 1R
0
5
10 5HWHQWLRQ WLPH >PLQ@
15
20 01 $SSO 1R
Nucleogelfi SUGAR 810 H Columnas tipo Valco. SeparaciĂłn de azĂşcares, alcoholes de azĂşcares y ĂĄcidos orgĂĄnicos - USP L17. Eluyente en columna 0,01N H2SO4. Tipo
7,8 mm ID
MACHEREY-NAGEL
Longitud
ud.E
CĂłdigo
mm 300
1
4.002 276
Precolumnas para Nucleogelfi SUGAR 810 H MACHEREY-NAGEL Tipo
4 mm ID
1236
Salvo error u omisiĂłn
ud.E
CĂłdigo
2
4.002 277
14. Cromatografรญa
GENERAL CATALOGUE 2010/11
Columnas para cromatografรญa/HPLC(alta resoluciรณn) Nucleogelfi SUGAR 810 Ca MACHEREY-NAGEL
Columnas tipo Valco. Separaciรณn de mono-, di- y oligosacรกridos - USP L19. Eluyente en columna agua. Tipo
Longitud
ud.E
Cรณdigo
mm 300
1
4.002 274
7,8 mm ID
Precolumnas para NUCLEOGEL fi SUGAR 810 Ca MACHEREY-NAGEL Tipo
4 mm ID
ud.E
Cรณdigo
2
4.002 275
Las precolumnas de cartucho ChromCart Nucleogelfi SUGAR 810 miden 30 x 4mm y requieren el soporte de columna CC 30mm. Las columnas vienen en pack/1, las precolumnas en pack/2.
MN column systems MACHEREY-NAGEL
VarioPrep columns
column system for preparative HPLC manufactured from stainless steel with one adjustable end fitting (on request, columns with two adjustable end fittings are also available, e.g for frequent use of backflushing techniques) allows compensation of a dead volume, which could result at the column inlet after some time of operation, without need for opening the column packed with NUCLEODURfi and NUCLEOSILfi spherical silica
Available standard dimensions of 9DULR3UHS FROXPQV ZLWK D[LDOO\ DGMXVWDEOH HQG ยฟ WWLQJ ,' [mm] 8 10 16 21 32 40 50 80
Length [mm] 10*
20*
x x
50
100
125
x x x x
x x x x x x x x
x x x x
x
x
(QG ำพ WWLQJ GHVLJQ 150
x x x x
250
x x x x x x x x
500
x
x x
[ PP ,' JXDUG FROXPQV UHTXLUH WKH 93 JXDUG FROXPQ KROGHU PP DQG DUH VXLWHG IRU DQG PP ,' 93 FROXPQV [ PP ,' JXDUG FROXPQV UHTXLUH WKH 93 JXDUG FROXPQ KROGHU PP DQG DUH XVHG IRU DQG PP ,' 93 FROXPQV
1 Soportes y recambios para precolumnas VarioPrep Juntas tรณricas bajo pedido.
1 MACHEREY-NAGEL
Descripciรณn para precolumnas de 8 y 10 mm ID para precolumnas de 16 y 21 mm ID
2 Accesorios para columnas VarioPrep
ud.E
Cรณdigo
1 1
4.002 176 4.002 175
2 MACHEREY-NAGEL
Descripciรณn
ud.E
"Plunger fitting" VP 10 mm Conector VP 10 mm Kit aislante VP 10 mm Arandelas de estanqueidad VP 10 mm Combinaciรณn de juntas MN Inert VP 10 mm "Plunger fitting" VP 21 mm Conector VP 21 mm Kit aislante VP 21 mm Arandelas de estanqueidad VP 21 mm Combinaciรณn de juntas MN Inert VP 21 mm
1 1 1 1 1 1 1 1 1 1 Salvo error u omisiรณn
Cรณdigo 4.002 4.002 4.002 4.002 4.002 4.002 4.002 4.002 4.002 4.002
209 210 218 212 211 215 216 213 214 217
1237
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/HPLC(alta resoluciĂłn) MN column systems EC standard columns for analytical HPLC
MACHEREY-NAGEL
analytical column system manufactured from stainless steel M 8 outer threads on both ends combination of sealing element and very fine-meshed stainless steel screen, PTFE sealing ring and fitting adaptor column heads SW 12 with inner threads M8 x 0.75 and UNF 10-32 as built -in guard columns use ChromCartfi guard column cartridges with 8 mm lenght with the guard column adaptor EC packed with NUCLEODURfi spherical silica
$YDLODEOH VWDQGDUG GLPHQVLRQV RI (& FROXPQV Ă&#x201A; SOHDVH DVN IRU DYDLODELOLW\ RI FHUWDLQ SKDVHV ,' [mm]
8*
20
50
2 4
â&#x20AC;&#x201C; x x â&#x20AC;&#x201C;
x x x x
x x x x
x x x x
/HQJWK >PP@ 75 100 125 x x x x
x x x x
x x x x
(QG Âż WWLQJ GHVLJQ 150
200
250
x x x x
x x x x
x x x x
x x x x
3OHDVH QRWH WKDW PP ,' JXDUG FROXPQ FDUWULGJHV DUH DSSOLFDEOH IRU PP ,' DQG PP ,' (& FROXPQV ZKLOH PP ,' JXDUG FROXPQ FDUWULGJHV DUH DOVR XVHG IRU PP ,' (& FROXPQV
,QVWDOODWLRQ RI WKH (& JXDUG FROXPQ DGDSWRU &DW 1R
(& FROXPQ ZLWK && JXDUG FROXPQ
Accesorios y recambios para columnas EC MACHEREY-NAGEL ud.E
DescripciĂłn
1 1 1 1 1 1 1 1
Adaptador de precolumna EC Conector de OD 1/16" para conectar capilares de 1/16" FĂŠrrula de 1/16" TapĂłn terminal de plĂĄstico de 1/16" Adaptador terminal EC Conector EC Arandelas de estanqueidad EC de PTFE Kit de juntas para columnas EC
1238
Salvo error u omisiĂłn
CĂłdigo 7.081 4.002 4.002 4.002 4.002 4.002 4.002 4.002
898 179 180 178 219 220 221 222
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/Instantáneo (Flash) 1 Chromabondfi Flash cartridges for Biotagefi systems
1
product range designed for use in Flash systems of Biotage AB (Flash 12i™ and FlashMaster™) without additional connectors or capillaries
MACHEREY-NAGEL
on request all column types listed below can be packed with any Chromabondfi adsorbent (please note that other packings often result in differing adsorbent weights) Chromabondfi Flash RS columns for Teledyne Iscofi systems (RS) on request.
Description
CHROMABONDfi CHROMABONDfi CHROMABONDfi CHROMABONDfi CHROMABONDfi CHROMABONDfi CHROMABONDfi CHROMABONDfi CHROMABONDfi CHROMABONDfi CHROMABONDfi CHROMABONDfi CHROMABONDfi
Flash Flash Flash Flash Flash Flash Flash Flash Flash Flash Flash Flash Flash
FM FM FM FM FM FM FM FM FM FM FM FM FM
15/2 SiOH 25/5 SiOH 25/10 SiOH 70/10 SiOH 70/20 SiOH 70/25 SiOH 150/25 SiOH 150/50 SiOH 150/70 SiOH 15/2 C18 ec 25/5 C18 ec 70/10 C18 ec 150/50 C18 ec
Column length
Int. dia.
Capacity
PK
cm 9.0 10.0 10.0 15.4 15.4 15.4 17.0 17.0 17.0 9.0 10.0 15.4 17.0
mm 15.80 20.50 20.50 26.80 26.80 26.80 38.20 38.20 38.20 15.80 20.50 26.80 38.20
g 2.0 5.0 10.0 10.0 20.0 25.0 25.0 50.0 70.0 2.0 5.0 10.0 50.0
50 50 50 30 30 30 20 20 10 50 20 20 10
Cat. No.
4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003
785 792 693 787 799 793 694 789 784 791 786 788 790
Gel de sílice estándar 60. MACHEREY-NAGEL Tamaño de poro ~ 60 Å; volúmen de poro ~ 0.75 ml/g; BET ~ 500 m2/g. altamente porosa, ácido silícico amorfo en forma de granos duros, fabricados por precipitación de vidrio soluble con ácido sulfúrico. Para requisitos especiales les recomendamos nuestros geles de sílice altamente puros POLYGOPRE. Gel de sílice FIA, para procedimientos de adsorción con indicadores fluorescentes en determinaciones de hidrocarburos en el análisis de combustibles según DIN 51791 y ASTM D 1319-58T. En el procedimiento FIA se determinan por cromatografía los hidrocarburos saturados, las olefinas y las sustancias aromáticas de una muestra en una columna rellena de gel de sílice FIA por adsorción y desorción en presencia de una mezcla de colorantes fluorescente. Descripción Gel de sílice 60, tamaño de grano: 0.015 - 0.04 mm Gel de sílice 60, tamaño de grano 0.025 - 0.04 mm Gel de silice 60, tamaño de grano 0.04 - 0.063 mm Gel de sílicea 60 M, tamaño de grano 0.04 - 0.063 mm Gel de sílice 60, tamaño de grano 0.05 - 0.1 mm Gel de sílice 60, tamaño de grano: 0.05 - 0.2 mm Gel de sílice 60, tamaño de grano: 0. 063 - 0.2 mm Gel de sílice 60, tamaño de grano: < 0.063 mm Gel de sílice 60, tamaño de grano:< 0.08 mm Gel de sílice 60, tamaño de grano:0.1 - 0.2 mm Gel de sílice 60, tamaño de grano:0.2 - 0.5 mm Gel de sílice 60, tamaño de grano:0.5 - 1.0 mm Gel de sílice 60, tamaño de grano:0.015 - 0.04 mm Gel de sílice60, tamaño de grano:0.025 - 0.04 mm Gel de sílice 60, tamaño de grano:0.04 - 0.063 mm Gel de sílice 60 M, tamaño de grano: 0.04 - 0.063 mm Gel de sílice 60, tamaño de grano:0.05 - 0.1 mm Gel de sílice 60, tamaño de grano: 0.05 - 0.2 mm Silica 60, 0. 063 - 0.2 mm Gel de sílice 60, tamaño de grano< 0.063 mm Gel de sílice 60, tamaño de grano< 0.08 mm Gel de sílice 60, tamaño de grano:0.1 - 0.2 mm Gel de sílice 60, tamaño de grano: 0.2 - 0.5 mm Gel de sílice 60, tamaño de grano: 0.5 - 1.0 mm Gel de sílice 60, tamaño de grano:0.015 - 0.04 mm Gel de sílice 60, tamaño de grano:0.025 - 0.04 mm Gel de sílice 60, tamaño de grano: 0.04 - 0.063 mm Gel de sílice 60 M, tamaño de grano:0.04 - 0.063 mm Gel de sílice 60, tamaño de grano:0.05 - 0.1 mm Gel de sílice 60, tamaño de grano:0.05 - 0.2 mm Gel de sílice 60, tamaño de grano:0. 063 - 0.2 mm Gel de sílice 60, tamaño de grano< 0.063 mm Gel de sílice 60, tamaño de grano< 0.08 mm Gel de sílice 60, tamaño de grano:0.2 - 0.5 mm Gel de sílice 60, tamaño de grano:0.5 - 1.0 mm Gel de sílice FIA fino Gel de sílice FIA grueso
Tamaño de partícula mesh/mm
230 230 130 70 70
- 400 - 400 - 270 - 270 - 230 + 230 + 190 70 - 130 35 - 70 18 - 35
mesh mesh mesh mesh mesh mesh mesh mesh mesh mesh
230 230 130 70 70
mesh mesh mesh mesh mesh mesh mesh mesh mesh mesh
- 400 - 400 - 270 - 270 - 230 + 230 + 190 70 - 130 35 - 70 18 - 35
230 230 130 70 70
- 400 mesh - 400 mesh - 270 mesh - 270 mesh - 230 mesh + 230 mesh + 190 mesh 35 - 70 mesh 18 - 35 mesh 0.071 - 0.16 mm 0.071 - 0.63 mm
Peso kg 1 1 1 1 1 1 1 1 1 1 1 1 5 5 5 5 5 5 5 5 5 5 5 5 25 25 25 25 25 25 25 25 25 25 25 1 1
Salvo error u omisión
ud.E 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Código 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.005 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.005 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004 4.004
999 948 968 971 974 954 957 977 951 960 962 965 001 950 970 973 976 956 959 979 953 961 964 967 000 949 969 972 975 955 958 978 952 963 966 980 981
1239
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/Instantáneo (Flash)-Almacenamiento/Manipulación de disolventes Aluminium oxide adsorbents for column chromatography aluminium oxides produced by dehydration of different aluminium hydroxides, e. g. hydrargillite between 400 and 500°C, activity grade I, particle size 50 to 200µm, specific surface (BET) ~ 130m²/g
Type
Aluminium Aluminium Aluminium Aluminium Aluminium Aluminium Aluminium Aluminium Aluminium
1240
Range
oxide oxide oxide oxide oxide oxide oxide oxide oxide
90 90 90 90 90 90 90 90 90
basic neutral acidic basic neutral acidic basic neutral acidic
pH pH 9,5 ± 0,3 pH 7 ± 0,5 pH 4 ± 0,3 pH 9,5 ± 0,3 pH 7 ± 0,5 pH 4 ± 0,3 pH 9,5 ± 0,3 pH 7 ± 0,5 pH 4 ± 0,3
MACHEREY-NAGEL
Weight
PK
kg 1 1 1 5 5 5 25 25 25
1 1 1 1 1 1 1 1 1
Salvo error u omisión
Cat. No.
4.004 6.231 4.004 4.004 4.004 4.004 4.004 4.004 4.004
934 726 939 936 938 941 935 937 940
Safety for Laboratory
and Production
Level control
Fire-resistant
Safety Specialist
WasteManagement
HPLC Extraction
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/Almacenamiento/Manipulación de disolventes 1 Safety Caps
1
La válvula de ventilación integrada bloquea los vapores perjudiciales y purifica el aire Scat circulante de partículas de polvo y suciedad. Mediante conexiones variables se pueden conectar múltiples capilares y tubos para la toma de líquidos. Los cierres están disponibles para todo tipo de frascos de laboratorio (por ejemplo, frascos de cristal con rosca GL45). Para otros recipientes existe el adaptador apropiado. Un accionado especial de las instalaciones HPLC evalúa las ventajas de SCAT Safety Caps, ya que los disolventes se mantienen libres de impurezas y la aparición de "Geisterpeaks" pertenece al pasado. También el cociente de mezcla se mantiene estable, puesto que los componentes ya no se pueden diluir más. Las ventajas más importantes: - no aparecen vapores perjudiciales - no existe suciedad - los tubos no giran - cambio simple de recipientes - ninguna aspiración de aire (HPLC) - ningún gasto por la dilución de los disolventes
2 3 Safety Caps Extracción segura de líquidos Con válvula de ventilación integrada. Para una función segura les recomendamos el cambio de la válScat vula de ventilación cada 6 meses, puesto que la válvula filtra las partículas de polvo y la suciedad del aire ambiental para proteger sus líquidos. La válvula se adapta universalmente a todos los tapones de seguridad, incluso cuando se emplean modelos antiguos; cambio simple de la válvula nueva! Descripción
Conexión
Safety Safety Safety Safety Safety Safety Safety Safety Safety Safety Safety
1 2 3 4 6 1 2 3 4 6 2
ud.E
Código
capilar (3,2 mm AD) capilares (3,2 mm AD) capilares (3,2 mm AD) capilares (3,2 mm AD) capilares (3,2 mm AD) capilar (3,2 mm AD) capilares (3,2 mm AD) capilares (3,2 mm AD) capilares (3,2 mm AD) capilares (3,2 mm AD) capilares (3,2 mm AD)
1 1 1 1 1 1 1 1 1 1 1
9.139 9.139 9.139 9.139 9.139 9.139 9.139 9.139 9.139 9.139 9.139
Safety Caps III, combinado, GL45 (2 con grifo / 1 sin grifo)
3 capilares (3,2 mm AD)
1
9.139 861
Safety Caps I, para 3/16 pulgadas, GL45 Safety Caps II para NS 29/32 frasco esmerilado
1 capilar (3/16 pulgadas AD) 2 capilares (3,2 mm AD)
1 1
9.139 862 9.139 863
Caps Caps Caps Caps Caps Caps Caps Caps Caps Caps Caps
I, GL45 II, GL45 III, GL45 IV, GL45 VI, GL45 con 1 grifo, GL45 II, con 2 grifos, GL45 III, con 3 grifos, GL45 IV, con 4 grifos, GL45 VI, con 6 grifos, GL45 II, combinado, GL45 (1 con grifo / 1 sin grifo)
2
3
850 851 852 853 854 855 856 857 858 859 860
4
4 Válvula de ventilación para SafetyCaps Valvula de ventilación para SafetyCaps, con filtro de aire integrado. La válvula se abre al ponerse en marcha la bomba HPLC y deja que el aire entre en el frasco - esto impide que se forme un vacío en el frasco. Tan pronto la bomba se para, la membrana se cierra herméticamente y ya no pueden salir los vapores nocivos del disolvente.
Descripción Valvula de ventilación para SafetyCaps Válvula de ventilación para SafetyCaps
1242
Salvo error u omisión
Scat
ud.E
Código
1 10
9.139 864 4.005 886
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/Almacenamiento/Manipulación de disolventes 1 SafetyCaps Basic ignífugo
1
Para frascos de disolvente GL45 en aparatos HPLC - ignífugos - color naranja - 1 hasta 6 conexiones opcionales
Descripción
Scat
Conexión 1 2 3 4 6
x x x x x
ud.E
conexión, diámetro exterior de 3,2 mm conexión, 3,2 mm de diámetro externo conexión 3,2 mm de diámetro exterior conexión de 3,2 mm de diámetro exterior conexión de 3,2 mm de diámetro exterior
1 1 1 1 1
2 SafetyCaps con grifo de cierre ignífugo
Conexión
SafetyCap SafetyCap SafetyCap SafetyCap SafetyCap
1 2 3 4 6
I GL45 II GL45 II GL45 IV GL45 VI GL45
x x x x x
conexión conexión conexión conexión conexión
4.005 4.005 4.005 4.005 4.005
770 780 781 776 779
2
Para frascos de disolvente GL45 en aparatos HPLC - con grifo de cierre - ignífugo - naranja - opcional 1 hasta 6 conexiones
Descripción
Código
Scat
ud.E 3,2 mm diámetro exterior con grifo de paso Ø 3,2 mm AD respectivamente con grifo de cierre Ø 3,2 mm AD respectivamente con grifo de cierre Ø 3,2 mm AD respectivamente con grifo de cierre Ø 3,2 mm diámetro exterior con grifo de paso
1 1 1 1 1
3 Válvula de ventilación ignífuga, naranja, para SafeyCaps
Código 4.005 4.005 4.005 4.005 4.005
772 785 786 777 778
3
La válvula se abre al ponerse en marcha la bomba HPLC y permite que el aire penetre y Scat circule por el frasco - esto evita que se forme el vacío en el frasco. Tan pronto como la bomba se para, se cierra herméticamente la membrana y ya no se pueden escapar los vapores nocivos de disolvente. Descripción Válvula de ventilación ignífuga, con filtro de aire integrado
4 Safety Waste Caps ignífugos, naranjas
Descripción
SafetyWasteCap GL45
1 1 1 2 1 3 4 1
SafetyWasteCap GL45 SafetyWasteCap GL45 SafetyWasteCap GL45
x x x x x x x x
Código
1
4.005 769
ud.E
Código
1
4.005 773
1
4.005 788
1 1
4.005 783 4.005 787
4
Para frascos de rosca GL45. El sistema de cierre consta de tapón y embudo de seguridad (bajo pedido) - ofrece una elevada flexibilidad en sus aplicaciones. Mediante el uso de PTFE y PE-HD puro los SafetyWaste Caps son resistentes a medios agresivos, por ejemplo, disolvente orgánicos, ácidos y lejías.
Descripción
ud.E
embudo de seguridad con tamiz conexión de 2,3/3,2 mm diámetro AD tubo de conexión de 6,4 mm ID conexión Ø 2,3/3,2 mm AD tubo de conexión Ø 6,4 mm ID conexión Ø 2,3/3,2 mm AD conexión Ø 2,3/3,2 mm AD tubo de conexión Ø 6,4 mm ID
Salvo error u omisión
Scat
1243
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/Almacenamiento/Manipulación de disolventes 1 Filtro de carbón activo ignífugo para Safety Waste Caps
1
Ignífugom, naranja. Para líquidos fácilmente inflamables
Scat
Descripción Filtro de ventilación tamaño S (24 g), ignífugo filtro de ventilación, tamaño M (48 g), ignífugo
ud.E
Código
1 1
4.005 782 4.005 784
2 3 Safety Waste Caps Para la recogida segura de residuos líquidos. Scat Safety Waste Caps tiene una conexión para el filtro del aire de salida. El filtro del aire de salida absorbe el 99% de todos los vapores y gases, que se pueden forman en la recogida de residuos líquidos. También aquí se tiene en cuenta la protección ambiental y de la salud. Para la fabricación de Safety Waste Caps se emplea PTFE puro o PE-HD, que garantiza una resistencia química máxima incluso frente a disolventes orgánicos agresivos. Solicitar el filtro para el aire de salida por separado Rosca
Conexión
GL45 GL45 GL80
3 conexión 2,3/3,2 mm diam.ext 2 conexión 2,3/3,2 mm diam.ext, 1 tubo 6,4 mm Diam interno 4 conexión 2,3/3,2 mm diam.ext, 1 tubo 6,4 mm Diam interno
2
Conexión
S51 S55 S60/61 S60/61 S70/71 S90
2 2 3 2 2 4
1244
x x x x x x
conexión conexión conexión conexión conexión conexión
Ø Ø Ø Ø Ø Ø
2,3/3,2 2,3/3,2 2,3/3,2 2,3/3,2 2,3/3,2 2,3/3,2
mm mm mm mm mm mm
AD, AD, AD AD, AD, AD,
1 1 1
9.139 865 9.139 866 9.139 869
ud.E
Código
4
diferente diámetro de rosca probablemente 1 hasta 4 conexiones Filtro de ventilación Embudo de seguridad Control del nivel de llenado
Rosca
Código
3
4 Safety Waste Caps con conexión de tubo rosca S -
ud.E
Scat
1 x conexión Ø 6,4 mm ID 1 x conexión Ø 6,4 mm ID
1 1 1 1 1 1
1 x conexión Ø 6,4 mm ID 1 x conexión Ø 6,4 mm ID 1 x conexión Ø 6,4 mm ID
Salvo error u omisión
4.005 4.005 9.139 9.139 4.005 9.139
583 584 867 868 585 870
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/Almacenamiento/Manipulación de disolventes
1 Safety Waste Caps
1
Rosca B con conexión de tubo
Rosca
Conexión
53B
4 1 4 1
83B
x x x x
conexión conexión conexión conexión
de de de de
Scat
2,3/2,2 mm diámetro ext. 6,4 mm diámetro exterior 2,3/3,2 mm diámetro ext. 6,4 mm diámetro exterior
2 Filtro de carbon activo para Safety Waste Caps
24 48 100
ud.E
Código
1 1 1
9.139 871 9.139 872 9.139 873
El filtro purifica el aire de salida de los vapores de disolvente. Con una superficie específica de 1200 m2/g este filtro de granulado especial a base de carbón activo es el medio de filtración óptimo para casi todos los vapores del disolvente - el 99% de las sustancias volátiles son absorbidas aquí.
4.005 441
1
4.005 438
ud.E
Código
1 1 1
4.005 634 4.005 631 4.005 635
3
Scat
Descripción
24 con pantalla protectora 48 con pantalla protectora 100 con pantalla protectora
4 Filtro de carbono activo para envases de almacenamiento de Safety Waste Caps Filtro de ventilación envase de almacenamiento (azul)
4 Scat
Descripción
Envase de almacenamiento S Envase de almacenamiento M
1
Scat
3 Filtro de carbón activo para Safety Waste Caps con defensa contra salpicaduras o pantalla protectora
Filtro de ventilación S - pequeño Filtro de ventilación M - mediano Filtro de ventilación L - grande
Código
2
Según la capacidad de recepción disponible existen 3 filtros de carbon activo para aproximadamente 3/6 ó 9 meses
Tamaño
ud.E
24 48
Salvo error u omisión
ud.E
Código
4 3
4.005 884 4.005 885
1245
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/Almacenamiento/Manipulación de disolventes 1 Piezas recolectoras para Safety Waste Caps
1
Para la conexión lateral del tubo
Scat
Descripción 2 3 2 3
2
ud.E
x capilar de conexión, 1 x tubo de conexión x tubo de conexión x tubo de conexión veces recolector para 3 capilares con 3,2 AD
1 1 1 1
Código 4.005 4.005 4.005 9.139
859 864 865 888
2 Piezas de recogida para Safety Waste Caps Con accesorios y junta cónica 3,2 mm. Para una conexión de tubo en vertical.
Scat
Descripción Recolector triple para 3 capilares con 3,2 AD 8 veces recolector para 8 capilares con 3,2 AD
ud.E
Código
1 1
9.139 888 9.139 889
3 Safety Waste Caps con embudo de seguridad
3
El embudo de seguridad se abre durante el abastecimiento de líquidos.Al sortar el Scat automático de cierre el recipiente se cierra automáticamente. Aqui se integra el filtro de ventilación, para la protección óptima de los vapores existentes. Cada cierre está dotado de conexiones variables para capilares y tubos.
4
Rosca
Conexión
S 50 S 55 S 60/61 S 65 S 70/71 83B S90 S95
2 2 2 4 4 4 4 4
x x x x x x x x
conexión conexión conexión conexión conexión conexión conexión conexión
ud.E 2,3/3,2 2,3/3,2 2,3/3,2 2,3/3,2 2,3/3,2 2,3/3,2 2,3/3,2 2,3/3,2
mm mm mm mm mm mm mm mm
diam diam diam diam diam diam diam diam
ext ext ext ext ext ext ext ext
1 1 1 1 1 1 1 1
Código 9.139 9.139 9.139 9.139 9.139 9.139 9.139 9.139
874 875 876 877 878 879 880 881
4 5 Safety Waste Caps con indicador automático del nivel de llenado -
tecnología SCAT Technologie garantizada de SafetyWasteCaps diferente diámetro de rosca conexiones 1 hasta 4 opcionales Filtro de ventilación Embudo de seguridad Control del nivel de llenado sin contacto opcional: SafeLock como equipo con el recipiente
Scat
5
Rosca
Conexión
S55 S60/61 S90
2 x conexión Ø 2,3/3,2 mm AD, 1 x conexión 6,4 mm ID 2 x conexión Ø 2,3/3,2 mm AD, 1 x conexión 6,4 mm ID 4 x conexión Ø 2,3/3,2 mm AD, 1 x conexión 6,4 mm ID
1246
Salvo error u omisión
ud.E
Código
1 1 1
4.005 612 4.005 613 4.005 616
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/Almacenamiento/Manipulación de disolventes 1
1 Control del nivel de llenado electrónico y sin contacto Supervise hasta 15 niveles de llenado al mismo tiempo con las cajas de señales Scat Además se pueden manipular los aparatos externos a través de un interruptor de contacto (contacto libre de potencial), por ejemplo, bombas o válvulas. Todas las cajas de señales se suministran con una fuente de alimentación (110/230 V). Sensor de disco Detección del nivel de llenado sin contacto con el contenido del recipiente. La sensibilidad del sensor de disco es ajustable para distintos grosores de pared. Adecuada para todos los recipientes de vidrio y de plástico no conductor. No adecuado para recipientes de acero inoxidable y cestas de plástico electroconductoras. Cable para la transmisión a la caja de señales y para la conexión de aparatos periféricos Combine el cable de alargamiento para mantener el recipiente a una distancia de hasta 200 metros. Vigile los aparatos conectados a través del cable de conexión con un contacto libre de potencial. Descripción
Descripción
Nivel de llenado Safety Set
Caja de señales con sensor del nivel de llenado de disco (1-canal), 220 V, fuente de alimentación EU, cable de señal de 3 metros, sensor del material de fijación Caja de señales con sensor de disco del nivel de vacio (1-canal), fuente de alimentación de 220 V EU, cable de señalización de 3 metros, sensor del material de fijación
Nivel de vacio Safety Set
2 Accesorios y junta cónica para Safety Waste Caps
ud.E
Código
1
4.005 638
1
4.005 797
2 Scat
Descripción
ud.E
Accesorios PP, universal Accesorios PP, universal Junta cónico PTFE, 1,6 mm DI Junta cónica de PTFE, 1,6 mm DI Junta cónica de PTFE 2,3 mm DI
5 10 5 10 5 10 5 10
Junta cónica de PTFE 3,2 mm DI Junta cónica de PTFE, 3,2 mm DI
Código 4.005 9.139 4.005 9.139 4.005 9.139 4.005 9.139
944 884 941 885 942 886 943 887
3 Ajustes PTFE con junta cónica integrada
3 Scat
Descripción para para para para para para para para
tubos tubos tubos tubos tubos tubos tubos tubos
ud.E
Ø 1,6 mm DE de 1,6 mm diámetro exterior de 2,3 mm de diámetro exterior de 2,3 mm de diámetro exterior de 3,2 mm de diámetro exterior de 3,2 mm de diámetro exterior de 4,76 mm diámetro exterior (3/16") de 6,35 mm (1/4") diámetro exterior
5 10 5 10 5 10 1 1
Código 4.005 4.005 4.005 4.005 4.005 4.005 4.005 4.005
938 444 939 445 940 446 448 447
4 Cierres
4
Roscas de cierre
Scat
Descripción para para para para para para para
ud.E
conexiones a capilares estándar Ø 3,2 mm DI, PTFE conexiones a capilares estandar Ø 3,2 mm DI, PTFE conexiones a capilares estándar Ø 3,2 mm DI, PTFE conexiones Ø 4,76 mm(3/16"), PTFE conexiones Ø 4,76 mm (3/16"), PTFE conexiones Ø 6,35 mm DI, PTFE conexión del viltro de ventilación
5 10 50 5 10 1 1
Código 4.005 4.005 4.005 4.005 4.005 4.005 4.005
946 881 947 945 880 883 504
5 Adaptador de rosca para Safety Waste Caps, PTFE
5 Scat
Descripción Adaptador GL38(w)-GL45(m) Adaptador GL40(w)-GL45(m)
Salvo error u omisión
ud.E
Código
1 1
9.139 882 9.139 883
1247
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/Almacenamiento/Manipulación de disolventes 1 Filtro de aspiración para disolventes
1
Filtro de disolvente HPLC
Scat
Descripción
ud.E
Código
5 5
4.005 890 4.005 891
Filtro de disolvente PP de HPLC, para Ø 1/8" (diámetro exterior 3,2 mm) Filtro de disolvente de HPLC PFA/PTFE, para Ø de 1/8" (Ø 3,2 mm diam exterior)
2
2 Embudo de seguridad PE-HD electroconductor Embudo de seguridad PE-HD, negro, electroconductor - cable de conexión a tierra incluido - para sustancias químicas de todo tipo - distintos tamaños de rosca - con o sin tamiz - para barriles - suministrado como un equipo con recipiente Rosca
Descripción
GL45 GL45 S55 S55 S60/61 S60/61 S65 S65 83B 83B
con con con con con con con con con con
Scat
ud.E
defensa ante salpicaduras tamiz para suciedad de acero inoxidable defensa ante salpicaduras tamiz para la suciedad de acero inoxidable defensa frente a salpicaduras tamiz para la suciedad de acero inoxidable defensa frente a salpicaduras tamiz de protección de acero inoxidable defensa frente a salpicaduras tamiz para suciedad de acero inoxidable
1 1 1 1 1 1 1 1 1 1
para todos los embudos de seguridad, electroconductor, negro
515 756 518 759 514 755 519 760 520 761
Scat
Descripción
ud.E
Código
1
4.005 537
Tamiz para la suciedad de acero inoxidable
4
4 Embudo de seguridad PE-HD, no conductor, blanco -
para todo tipo de sustancias químicas diferentes tamaños de rosca con o sin tamiz para barriles
Rosca
Descripción
GL45 GL45 S55 S55 S60/61 S60/61 S65 S65 83B 83B
con con con con con con con con con con
Scat
ud.E
defensa contra salpicaduras tamiz para la suciedad de acero defensa contra salpicaduras tamiz para la suciedad de acero defensa contra salpicaduras tamiz para la suciedad de acero defensa contra salpicaduras tamiz para la suciedad de acero defensa contra salpicaduras tamiz para la suciedad de acero
1 1 1 1 1 1 1 1 1 1
inoxidable inoxidable inoxidable inoxidable inoxidable
Código 4.005 4.005 4.005 4.005 4.005 4.005 4.005 4.005 4.005 4.005
621 741 624 744 620 740 625 745 628 748
5 Tamiz de acero fino para la suciedad para embudos de seguridad, blanco para todos los embudos de seguridad, blanco
Descripción Tamiz de acero fino para la suciedad, para todos los embudos de seguridad blanco
1248
4.005 4.005 4.005 4.005 4.005 4.005 4.005 4.005 4.005 4.005
3 Tamiz para la suciedad de acero inoxidable
3
5
Código
Salvo error u omisión
Scat
ud.E
Código
1
4.005 540
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/Almacenamiento/Manipulación de disolventes 1 Sistemas de conexión Tapas de seguridad DG
1
Las tapas de seguridad DG son sistemas de conexión flexibles, desarrollados DURAN Group específicamente para el manipulado con líquidos agresivos y gasógenos. Equipadas de forma individualizada con 1, 2 ó 3 tomas - con o sin llaves de paso - las tapas de seguridad DG son particularmente adecuadas para aplicaciones en la industrias farmacéutica y química. - No se produce salida de gases peligrosos - Los tubos flexibles no pueden resbalar - No se produce merma de sustancias por evaporación - Limpieza en el trabajo Las tapas de seguridad van completamente equipadas, incluyendo una junta cónica (Øint=3,2 mm) y se pueden utilizar directamente. Para adaptarse a otras aplicaciones se ofrecen op¬cionalmente juntas cónicas para 2 diámetros de tubo flexible adicionales (Øext=1,6 y 2,3 mm). Las tapas de seguridad DG para desechos son idóneas para la conservación segura y la recogida de residuos líquidos en el laboratorio. Gracias a la variedad de posibilidades de conexión que ofrecen y a sus filtros de carbón activado, mejoran la seguridad del personal de laboratorio. - Recogida sin goteo de medios usados o contaminados - Los filtros de carbón activado previenen la salida de gases nocivos - Posibilidades de conexión adicionales para filtros de carbón activado y tubos de fuga Descripción Tapa Tapa Tapa Tapa Tapa Tapa Tapa Tapa Tapa
de de de de de de de de de
seguridad seguridad seguridad seguridad seguridad seguridad seguridad seguridad seguridad
ud.E DG I (1 toma) DG II (2 tomas) DG III (3 tomas) DG I (1 toma), con llave de paso DG II (2 tomas), con llaves de paso DG III (3 tomas), con llaves de paso para NS 29/32 para desechos GL 45 para desechos GL 45, para tubo fuga
1 1 1 1 1 1 1 1 1
Código 9.072 9.072 9.072 9.072 9.072 9.072 9.072 9.072 9.072
530 531 532 533 534 535 536 537 538
2 3 Accesorio para sistema de conexión Tapas de seguridad DG DURAN Group Descripción
ud.E 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Filtro de carbón activado pequ., capacidad 24 g Filtro de carbón activado grande, capacidad 48 g Tornillo de conexión, PP (juego de repuesto) Válvula de ventilación Adaptador de rosca GL 40/GL45 PTFE Adaptador de rosca GL 40/GL45 PP Adaptador de rosca GL 38/GL45 PTFE Adaptador de rosca GL 38/GL45 PP Adaptador de rosca GL 32/GL45 PTFE Adaptador de rosca GL 32/GL45 PP Tornillos ciegos PTFE UNF 1/4'' Junta cónica, Ø int. 1,6 mm, PTFE Junta cónica, Ø int. 2,3 mm, PTFE Junta cónica, Ø int. 3,2 mm, PTFE Tornillo conexión con jta. cónica, Ø int. 1,6 mm, PTFE Tornillo conexión con jta. cónica, Ø int. 2,3 mm, PTFE Tornillo conexión con jta. cónica, Ø int. 3,2 mm, PTFE Herram. montaje para tornillo con. PP (llave macho) Herram. montaje para tornillo conexión de PTFE Tapón ciego NPT 1/8", para conexión fugas, PTFE Filtro membrana para válvula de ventilación, 1 µm, membrana de PTFE
2
Código 9.209 9.209 9.209 9.209 9.209 9.209 9.209 9.209 9.209 9.209 9.209 9.209 9.209 9.209 9.209 9.209 9.209 9.209 9.209 9.209 9.209
090 091 092 093 094 095 096 097 098 099 100 101 102 103 104 105 106 107 108 109 110
3
Salvo error u omisión
1249
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/Almacenamiento/Manipulación de disolventes 1
1 Frasco DURANfi HPLC, sistema completo, tapón de rosca de 4 orificios Para la transferencia estéril de líquidos o para la alimentación de equipo HPLC con DURAN Group disolventes. El frasco es resistente a la presión entre -1 y +1,5 bar y resistente al vacío (según la norma EN 1596, certificada mediante el sello TÜV). Completo con cierre roscado de 4 puertos (autoclavable, reutilizable). Apto para tubos flexibles de 1,6 mm y 3,2 mm de diámetro. Las piezas de recambio pueden adquirirse por separado. Otros componentes del sistema de conexión para roscas GL45 a petición. (Los tubos flexibles no están incluidos en el volumen de suministro). Con código de retorno (identificación de lote), con certificado disponible via internet. Vidrio neutro/tipo I conforme a USP/EP Capacidad ml 500 1000
2
ud.E
Código
1 1
9.072 526 9.072 525
2 3 Accessories for connecting system for Duranfi GL 45 bottles (HPLC) DURAN Group
3
Description
PK
Cat. No.
Screw cap HPLC GL 45, 4 Port complete Spare set for HPLC screw cap
1
6.226 328
1
6.226 329
Pressure equilization, 0,2 µm for 4-Port-cap, incl. membrane filter
1
6.226 915
Spare membrane filter for pressure equilization, 0,2 µm Bottle 1000 ml, GL 45, Duran pressure resistant up to +1,5 bar Bottle 500 ml, GL 45, Duran pressure resistant up to +1,5 bar
1
6.230 844
1
9.971 704
1
9.071 707
1250
Salvo error u omisión
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/Almacenamiento/Manipulación de disolventes 1 Sistema de conexión flexible para frascos DURAN GL45 (HPLC)
1
Materiales utilizados: PP y PTFE. Sistema modular flexible. Se pueden conectar cuatro DURAN Group diámetros de tubo distintos (1,6 mm; 3,0 mm; 3,2 mm; y 6,0 mm). Es posible una equalización de presión estéril mediante el uso de un filtro de membrana. Los orificios no usados se pueden tapar. Aplicaciones típicas: transporte seguro de medios líquidos en un sistema cerrado y esterilizado (se reduce la evaporación) Ejemplo de pedido Le gustaría ajustar dos botellas a un sistema de conexión de 3 orificios. Le gustaría trabajar con dos diámetros de tubo distintos (1,6 mm y 3 mm) y equalización de la presión. Por consiguiente, necesita los componentes individuales siguientes: Tapón de rosca GL 45 3 orificios (Art. nr. 7.263 018) 1 estuche (2 por estuche) Tapón de rosca GL 14 (art. nr. 6.227 781) 2 estuches (2 por estuche) Inserto para tapón de rosca GL14 diámetro interior 1,6 mm (art.nr. 6.229 494)2 estuches (1 por estuche) Inserto para tapón de rosca GL14 diámetro interior 3,0 mm (art. nr. 6.229 495) 2 estuches (1 por estuche); Equipo de equalización de la presión (completo) (art. nr. 6.228 023) 2 estuches (1 por estuche)
Descripción
ud.E
Tapón de rosca GL 45, 2 Port GL 14 Tapón de rosca GL 45, 3 Port GL 14 Tapón de rosca GL 14 para conector de tubos Pieza para el tapón de rosca GL 14, Ø int. 1,6 mm Pieza para el tapón de rosca GL 14, Ø int. 3,0 mm Pieza para el tapón de rosca GL 14, Ø int. 3,2 mm Pieza para el tapón de rosca GL 14, Ø int. 6,0 mm Tapón de rosca GL 14, rojo Equalizador de presión, filtro de 0,2 µm, para tapón de rosca de 2/3 orificios Ersatz-Membranfilter für Druckausgleichset, 0,2 µm Frasco 1000 ml, GL 45, Duran resistente a la presión hasta +1,5 bar Frasco 500 ml, GL 45, resistente a la presión hasta +1,5 bar, Duran
1 1 1 1 1 1 1 1 1 2 1 1
2 3 Scrubber Adapter for Bottles
Código 6.227 7.623 6.227 6.229 6.229 6.230 6.227 7.623 6.228 6.230 9.971 9.071
780 018 781 494 495 213 782 838 023 844 704 707
2
Consisting of PTFE body with connecting nut and two lateral GL18 threaded necks, a Bohlender 300mm long FEP inlet tube and a gas distributor with frit. Easy in- and outlet of gas by means of rigid-walled tubing (e.g. PTFE) which can be connected to the threaded necks using Bola Laboratory Screw Joints. Elastic tubing can be connected by means of hose connectors. Inlet tube can be individually shortened. Special feature: the body of the adapter can be turned independently from the connecting nut. This means, that the completely assembled adaptor can be removed and fixed onto another bottle without the risk of disarranging the tubing. Suitable for bottles from Duran Group (formerly Schott, Mainz) with GL45 or GLS80 threads and capacities between 100 and 5000ml.
3 For thread type Thread GL45 Thread GLS 80
PK
Cat. No.
1 1
9.110 310 9.110 311
4 Distributors for Reaction Vessels (R)
4
Blue screw cap made of PP with GLS80 thread and PTFE body. Centre neck with GL25 thread for connecting tubing up to 15 mm o.d., four lateral necks with GL18 thread. Exchangeable shaft guide (PTFE) with screw cap (PPS) for inserting and fixing a stirrer shaft in the centre neck included.
Bohlender
Very good chemical resistance, for working temperatures up to max.+250°C (PP screw cap max. +140°C). Centre neck
Lateral neck
For diam. stirrer shaft
GL 25 GL 25
4 x GL 18 4 x GL 18
8 mm 10 mm
Salvo error u omisión
PK
Cat. No.
1 1
9.209 920 9.209 921
1251
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/Almacenamiento/Manipulación de disolventes 1
1 Cabezales para frascos con varias entradas PTFE, con cuellos roscados GL y tapones roscados. Sirven para frascos de rosca GL 45. Bohlender Ideal para el trasvase de líquidos. Los cuellos se puede conectar a un sistema dispensador de líquido o a un sistema de sobrepresión o depresión (hasta 6 mm de diámetro máximo). Para empalmar tubos con facilidad recomendamos los adaptadores roscados BOLA, que se tienen que encargar aparte y en función del diámetro exterior del tubo.
2
Tipo
Boca
PTFE PTFE PTFE
2 x GL 14 3 x GL 14 3 x GL 18
ud.E
Código
1 1 1
9.209 851 9.209 852 9.209 844
2 Ground Joint GL Adapters Bohlender Black screw cap made of PPS with GL45 thread or blue screw cap made of PP with GLS80 thread, movable insert with ground joint made of PTFE. Transition from a ground joint to a glass thread. The body can be turned independently from the screw cap. The complete, assembled adapter can be removed and fixed onto another bottle without the risk of disarranging the tubing. Very good chemical resistance, for working temperatures up to max. +250°C. Type
3
Joint size NS
PK
Cat. No.
1
6.224 507
3 4 Flexible Distributors Polypropylene. For connecting elastic tubing by simply slipping it onto hose connectors. Bohlender Suitable for GL45 threaded bottles. With screw cap made of glass-fibre reinforced PP, ideal for transferring liquids or gases. The angled tubing connectors can be attached to a liquid source, or to a pressure or vacuum system and avoid crimping of the tubing. The distributor can be loosened by simply turning the screw cap. The complete distribution system can then be fixed onto another bottle.
4
5
number of nozzles For tubing bore mm 2 6 - 9 mm 3 6 - 9 mm 2 7 - 11 mm
PK
Cat. No.
1 1 1
7.634 892 9.209 858 9.209 859
5 Conexiones GL Conexiones de PTFE con unión roscada GL. Sirven para unir de forma segura tubos de Bohlender PTFE, PFA, FEP y tubos de vidrio o metal. Soportan la acción de casi cualquier sustancia. Resisten hasta aprox. 250°C. En combinación con las uniones roscadas BOLA pueden trabajar con presiones de hasta 10 bar (a temperatura ambiente). Otra ventaja consiste en que se pueden conectar a una sola pieza central tubos rígidos o tubos de diámetros exteriores diferentes. Para conectar tubos con facilidad recomendamos las conexiones roscadas BOLA. Éstas tienen que pedirse aparte y según el diámetro exterior de tubo.
Roscas GL 14 18 25
1252
Ø Orificio
ud.E
Código
mm 6,5 10,5 14,5
1 1 1
9.207 113 9.207 114 9.207 115
Salvo error u omisión
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/GC(cromatografĂa de gas)
Summary of MN phases for GC )RU FRPSRQHQWV IHDWXULQJ GLÓ˝ HUHQW K\GURJHQ ERQG LQJ FDSDFLWLHV DQG WKH DELOLW\ WR IRUP VWURQJ K\GURJHQ ERQGV SRO\HWK\OHQH JO\FRO SKDVHV :$; DUH WKH EHVW FKRLFH IRU D VHSDUDWLRQ 7\SLFDO DQDO\WHV DUH DOFRKROV DQG FDUER[\OLF DFLGV
01 RÓ˝ HUV PRUH WKDQ GLÓ˝ HUHQW SKDVHV IRU JDV FKUR PDWRJUDSK\ IURP YHU\ QRQSRODU WR SRODU FROXPQV 1RQSRODU VWDWLRQDU\ SKDVHV H J GLPHWK\OSRO\ VLOR[DQH SKDVHV VHSDUDWH E\ YRODWLOLW\ L H ERLOLQJ SRLQW RQO\ 7\SLFDO DQDO\WHV DUH OLQHDU K\GURFDUERQV Q DONDQHV
6HOHFWLYLW\ KDV WR EH RSWLPL]HG IRU WKH FULWLFDO SDLU RI FRPSRQHQWV RU IRU WKH PDLQ FRPSRQHQW <RX VKRXOG DOZD\V VHOHFW WKH OHDVW SRODU FROXPQ ZKLFK VROYHV \RXU VHSDUDWLRQ WDVN $ERXW RI DOO VHSDUDWLRQV FDQ EH SHUIRUPHG RQ QRQ WR PLGSRODU FROXPQV 7KHVH FRO XPQV JHQHUDOO\ IHDWXUH KLJK WHPSHUDWXUH VWDELOLW\
3RODU SKDVHV Rӽ HU DGGLWLRQDO LQWHUDFWLRQV ZKLFK PD\ LPSURYH D VHSDUDWLRQ :KHQ LQFUHDVLQJ WKH SRODULW\ H J E\ LQWURGXFLQJ SKHQ\O DQG RU F\DQRSURS\O JURXSV VHSDUDWLRQ LV LQFUHDVLQJO\ LQӿ XHQFHG E\ GLӽ HUHQFHV LQ GLSROH PRPHQW DQG E\ FKDUJH WUDQVIHU Hӽ HFWV H J IRU ² GLSKHQ\OSRO\VLOR[DQH SKDVHV 7\SLFDO DQDO\WHV DUH K\GURFDUERQV ZKLFK FRQWDLQ R[\JHQ VXOSKXU QL WURJHQ SKRVSKRUXV RU KDORJHQ DWRPV XQVDWXUDWHG PROHFXOHV ZKLFK FDQ EH SRODULVHG DQG DURPDWLFV
Comparison of separation properties of selected OPTIMAÂŽ phases 3
1 3
5
2 4
6
3
8 9 10
8
7
5 1
OPTIMAÂŽ 225
6 74
PD[ WHPS Â&#x192;&
OPTIMAÂŽ 1701
9 10
PD[ WHPS Â&#x192;& 4
2
6 7
8 9 10
5
3 1 4 25
OPTIMAÂŽ 17 PD[ WHPS Â&#x192;&
6
8 9 10
7
OPTIMAÂŽ 5 PD[ WHPS Â&#x192;&
1 2 3 4
0
All columns: Sample: Injection: Carrier gas: Temperature: Detector:
10
5
6
8
7
20
min
OPTIMAÂŽ 1 9 10
PD[ WHPS Â&#x192;&
increasing polarity
Capillary columns for GC
1 2
30
Peaks: 1. Undecane 2. Dodecane 3. Octanol 4. Dimethylaniline 5. Decylamine
Ä&#x201A;P Óž OP P [ PP ,' MN-OPTIMAÂŽ test mixture 1.0 Âľl, split 1:50 80 kPa N2 80 °C A Tmax (isothermal), 8 °C/min FID, 260 â&#x20AC;&#x201C; 300 °C, 26
6. Methyl decanoate 7. Methyl undecanoate 8. Henicosane 9. Docosane 10. Tricosane
(DFK FROXPQ LV LQGLYLGXDOO\ WHVWHG DQG VXSSOLHG ZLWK WHVW FHUWLÓž FDWH DQG WHVW FKURPDWRJUDP EXW ZLWKRXW Óž WWLQJV RU IHUUXOHV &ROXPQ HQGV DUH PHOWHG RU FORVHG ZLWK VHSWD DQG WKXV SURWHFWHG IURP DWPRVSKHULF R[\JHQ $GGLWLRQDOO\ ZH LQFOXGH WKH FRUUHVSRQGLQJ WHVW PL[WXUH ZLWK HDFK FROXPQ 2Q UHTXHVW DOO FROXPQV FDQ EH VXSSOLHG ZLWK D LQFK FP FDJH IRU WKH $JLOHQW *&
Salvo error u omisiĂłn
1253
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/GC(cromatografĂa de gas)
Summary of MN phases for GC
Phase
Composition
max. temperature 1
2
USP
Similar phases
G1 G2 G38 G1 G2 G38
PERMABONDÂŽ SE-30, OV-1, DB-1, SE-30, HP-1, SPB-1, CP-Sil 5 CB, RtxÂŽ-1, 007-1, BP1, MDN-1, ATâ&#x201E;˘-1, ZB-1, OV-101
Standard phases OPTIMAÂŽ 1
100 % dimethylpolysiloxane
340/360 °C
OPTIMAÂŽ 1 MS Accent
100 % dimethylpolysiloxane
340/360 °C
OPTIMAÂŽ 5
5 % phenyl â&#x20AC;&#x201C; 95 % methylpolysiloxane
340/360 °C
OPTIMAÂŽ 5 MS
OPTIMAÂŽ 17 OPTIMAÂŽ 624
340/360 °C
340/360 °C
320/340 °C 280/300 °C
PERMABONDÂŽ SE-52, SE-54, SE-52, DB-5, G27 HP-5, SPB-5, CP-Sil 8, RtxÂŽ-5, 007-5, BP5, G36 MDN-5, ATâ&#x201E;˘-5, ZB-5 G27 G36 DB-5MS, HP-5MS, Ultra-2, Equityâ&#x201E;˘-5, CP-Sil 8CB low bleed/MS, RtxÂŽ-5SIL-MS, RtxÂŽ-5MS, G27 007-5MS, BPX5, MDN-5S, ATâ&#x201E;˘-5MS, VF-5MS G36 G3
OV-17, DB-17, HP-50+, HP-17, SPB-50, SP2250, RtxÂŽ-50, CP-Sil 24 CB, 007-17, ZB-50
DB-624, DB-VRX, SPB-624, G43 HP-624, HP-VOC, CP-624, RtxÂŽ-624, RtxÂŽ-Volatiles, 007-624, G43 BP624, VOCOL
OPTIMAÂŽ 624 LB as above, low bleed phase
280/300 °C
OPTIMAÂŽ 1701
14 % cyanopropylphenyl â&#x20AC;&#x201C; 86 % dimethylpolysiloxane
300/320 °C
OV-1701, DB-1701, CP-Sil 19 CB, HP-1701, G46 RtxÂŽ-1701, SPB-1701, 007-1701, BP10, ZB1701
OPTIMAÂŽ 225
50 % cyanopropylmethyl â&#x20AC;&#x201C; 50 % phenylmethylpolysiloxane
260/280 °C
G7 DB-225, HP-225, OV-225, RtxÂŽ-225, CP-Sil G19 43, 007-225, BP225
OPTIMAÂŽ WAX
polyethylene glycol 20 000 Dalton
250/260 °C
G16
OPTIMAÂŽ FFAP
polyethylene glycol-2-nitroterephthalate
250/260 °C
PERMABONDÂŽ CW 20 M, DB-Wax, Supelcowaxâ&#x201E;˘, HP-Wax, HP-INNOWax, RtxÂŽ-Wax, CP-Wax 52 CB, Stabilwax, 007-CW, BP20, ATâ&#x201E;˘-Wax, ZB-Wax G25 PERMABONDÂŽ FFAP, DB-FFAP, HP-FFAP, G35 CP-SIL 58 CB, 007-FFAP, CP-FFAP CB, Nukol
Phases for special separations 5 % phenyl â&#x20AC;&#x201C; 95 % methylpolysiloxane, G27 300/320 °C Rtx-5 Amine, PTA-5 specially deactivated for G36 amine separations octakis-(2,6-di-O-pentyl 2 EXW\U\O Ćś F\FORGH[WULQ 200/220 °C â&#x20AC;&#x201C; â&#x20AC;&#x201C; LIPODEXÂŽ E for enantiomer separation heptakis-(2,3-di-O-methylHYDRODEX 6-O-t-butyldimethyl-silyl)230/250 °C â&#x20AC;&#x201C; â&#x20AC;&#x201C; Ćľ F\FORGH[WULQ IRU HQDQWL Ćľ 7%'0 omer separation heptakis-(2,3-di-O-acetylHYDRODEX 6-O-t-butyldimethyl-silyl)220/240 °C â&#x20AC;&#x201C; â&#x20AC;&#x201C; Ćľ F\FORGH[WULQ IRU HQDQWL Ćľ 7%'$F omer separation 1 Óž UVW WHPSHUDWXUH IRU LVRWKHUPDO RSHUDWLRQ VHFRQG YDOXH IRU VKRUW LVRWKHUPV LQ D WHPSHUDWXUH SURJUDPPH 3OHDVH QRWH WKDW IRU FROXPQV ZLWK PP ,' DQG IRU FROXPQV ZLWK WKLFNHU Óž OPV WHPSHUDWXUH OLPLWV DUH JHQHUDOO\ ORZHU )RU GHWDLOV refer to the description of individual phases. 2 phases which provide a similar selectivity based on chemical and physical properties
OPTIMAÂŽ 5 Amine
1254
Salvo error u omisiĂłn
Capillary columns for GC
OPTIMAÂŽ 5 MS Accent
5 % diphenyl 95 % dimethylpolysiloxane silarylene phase with selectivity similar to 5 % diphenyl â&#x20AC;&#x201C; 95 % dimethylpolysiloxanphasee phenylmethylpolysiloxane, 50 % phenyl 6 % cyanopropylphenyl â&#x20AC;&#x201C; 94 % dimethylpolysiloxane
Ultra-1, DB-1MS, HP-1MS, RtxÂŽ-1MS, Equityâ&#x201E;˘-1, ATâ&#x201E;˘-1MS, VF-1MS, CP-Sil 5 CB MS
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/GC(cromatografía de gas) 1 Columnas capilares OPTIMAfi 1 para la CG 100% dimetilpolisiloxano
MACHEREY-NAGEL
1
fase no polar Separación de componentes según el punto de ebullición grosor de película ≥ 3 µm, en particular para la analítica de disolventes USP G1/G2/G38 fases similares: PREMABONDfi SE30, OV-1, DB-1, SE-30, HP™1, SPB™1, CP-Sil 5 CB, Rtx-1, 007™1, BP1,MDN™1, AT1, ZB-1,OV-101 para columnas con 0,2-0,32 mm DI y grosores de película <3µm la temperatura máxima para el modo de trabajo isotérmico es de 340ºC, la temperatura máxima para isotermas cortas en un programa de temperatura es de 360ºC para columnas con DI de 0,53 mm y grosores de película < 3µm las temperaturas máximas son de 320 o 340ºC para columnas con grosores de película ≥ 3 µm las temperaturas máximas ascienden a 300 ó 320ºC Tipo
0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,32 0,32 0,32 0,32 0,32 0,32 0,32 0,32 0,32 0,32 0,32 0,32 0,32 0,32 0,32 0,32 0,32 0,32 0,32 0,32 0,32 0,32 0,32 0,32 0,32 0,32 0,32
mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm
DI (0,4 mm DE) DI(0,4 mmDE) DI (0,4 mm DE) DI(0,4 mm DE) DI(0,4 mm DE) DI(0,4 mm DE) DI (0,4 mm DE) DI (0,4 mm DE) DI(0,4 mm DE) DI(0,4 mm DE) ID DI(0,4 mm DE) ID DI (0,4 mmDE) ID DI (0,5 mm DE) ID DI(0,32 mm DE) ID DI(0,5 mm DE) ID DI(0,5 mm DE) DI (0,5 mm DE) ID ID DI (0,5 mm DE) DI (0,5 mm DE) ID DI (0,5 mm DE) ID ID ID ID ID DI (0,5 mm DE) ID ID DI(0,5 mm DE) ID ID ID ID
0,53 mm DI (0,8 mm DE) 0,53 mm DI (0,8 mm DE)
0,53 mm DI (0,8 mm DE) 0,53 mm DI (0,8 mm DE) 0,53 mm d.i. (0,8 mm d.e.)
Grosor de película
Longitud
ud.E
µm 0,10 0,25 0,50 1,00 0,10 0,25 0,50 1,00 0,25 0,50 1,00 0,10 0,25 0,50 1,00 0,10 0,25 0,35 0,50 1,00 3,00 5,00 0,10 0,25 0,35 0,50 1,00 3,00 5,00 0,10 0,25 0,35 0,50 1,00 3,00 5,00 0,10 0,25 0,35 0,50 1,00 3,00 0,50 1,00 2,00 5,00 0,50 1,00 2,00 5,00 5,00
m 25 25 25 25 30 30 30 30 50 50 50 60 60 60 60 25 25 25 25 25 25 25 30 30 30 30 30 30 30 50 50 50 50 50 50 50 60 60 60 60 60 60 25 25 25 25 30 30 30 30 50
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Código
9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003
657 662 667 671 658 663 668 672 664 669 673 659 665 670 674 676 682 686 691 697 701 706 677 683 687 692 698 702 707 678 684 688 693 699 703 708 679 685 689 694 700 704 149 164 152 265 150 165 153 266 267
Además del programa estándar aquí indicado suministramos también columnas conforme a la especificación del cliente. Cada columna se verifica por separado y se suministra con un certificado de prueba y el cromatograma de pruebas, pero sin ajustes de cierre o Ferrules.Todas las columnas se cierran con tapones en sus extremos y se protegen de ese modo de la entrada de oxígeno. Además disponemos de la mezcla de ensayo empleada.
Salvo error u omisión
1255
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/GC(cromatografĂa de gas) 1 Columnas capilares OPTIMAfi 1 MS Accent para GC
1
100% dimetilpolisiloxano
MACHEREY-NAGEL
fase no polar con sangrado ultra-mĂnimo, ideal para detectores MS ion-trap y quadrupol sensibilidad elevada debido a un nivel de seĂąal de ruido mĂnimo perfecta inactividad para compuestos bĂĄsicos lavado de solventes para la eliminaciĂłn de impurezas aplicable a todo tipo de aplicaciones: fase para anĂĄlisis ambientales, anĂĄlisis de trazas, mĂŠtodos EPA, pesticidas, PCB, analisis de alimentos y fĂĄrmacos fases similares: Ultra-1, DB-1, MS, HP-1, MS, Rtx-1, MS, Equityâ&#x201E;˘1, AT-1 MS, VF-1 MS, CP-Sil 5 CB MS temperatura mĂĄxima para funcionamiento isotĂŠrmico 340ÂşC, mĂĄx. temperatura para isotermas cortas en un programa de temperatura 360ÂşC
Tipo
0,25 mm DI (0,4 mm DE) 0,25 mm DI (0,4 mm DE) 0,25 mm DI (0,4 mm DE) 0,32 0,32 0,32 0,32
mm mm mm mm
DI (0,5 mm DE) DI(0,5 mm DE) DI (0,5 mm DE) DI (0,5 mm DE)
Grosor de pelĂcula
Longitud
ud.E
Âľm 0,25 0,50 0,25 0,50 0,25 0,50 0,25 0,50
m 30 30 60 60 30 30 60 60
1 1 1 1 1 1 1 1
CĂłdigo
4.003 4.003 4.003 4.003 4.002 4.003 4.002 4.003
001 003 002 004 998 005 999 006
Cada columna es analizada por separado y se suministra con el certificado de anĂĄlisis y el cromatograma de prueba, pero sin ajustes o ferrules. Todas las columnas se cierran con tapones y se protegen de la entrada de oxĂgeno. AdemĂĄs, nosotros suministramos la mezcla de prueba correspondiente con cada columna
2
EPA 8140 / 8141 / 8141 A org. P pesticides Column: OPTIMAÂŽ 06 $FFHQW Ç&#x2039;P Âż OP P [ PP ,' 6DPSOH Ç&#x2039;J PO LQ KH[DQH 23 SHVWLFLGHV FDOLEUDWLRQ mix A + 8141 OP pesticides calibration mix B; IS triphenyl phosphate and tributyl phosphate
13
Injection splitless (for 1 min); inj. temperature 250 °C Carrier gas He, 1 ml/min, constant pressure Temperature 100 °C A 180 °C, 10 °C/min (2 min) A 300 °C, 18 °C/min (3 min) 'HWHFWRU )3' Ă&#x20AC; DPH SKRWRPHWULF GHWHFWRU Â&#x192;& Peaks: 1. Dichlorvos, 2. Hexamethylphosphoramide, 3. Mevinphos, 4. Trichlorfon, 5. TEPP, 6. Thionazin, 7. Demeton-O, 8. Ethoprop 9. Tributyl phosphate (IS), 10. Dicrotophos, 11. Monocrotophos, 12. Naled, 13. Sulfotepp, 14. Phorate, 15. Dimethoate, 16. Demeton-S, 17. Dioxathion, 18. Terbufos, 19. Fonophos, 20. Phosphamidon-Isomer, 21. Diazinon, 22. Disulfoton, 23. Phosphamidon, 24. Dichlorofenthion, 25. Parathion-methyl, 26. Chlorpyrifos methyl, 27. Ronnel, 28. Fenitrothion, 29. Malathion, 30. Fenthion, 1 31. Aspon, 32. Parathion-ethyl, 33. Chlorpyrifos, 34. Trichloronate, 35. Chlorfenvinphos, 36. Merphos, 37. Crotoxyphos, 38. Stirofos, 39. Tokuthion, 40. Merphos oxidation product, 41. Fensulfothion, 42. Famphur, 43. Ethion, 44. Bolstar, 45. Carbophenothion, 46. Triphenyl phosphate (IS), 47. Phosmet, 48. EPN, 49. Azinphosmethyl, 50. Leptophos, 51. Tri-o-cresyl phosphate, 52. Azinphosethyl, 53. Coumaphos
MN Appl. No. 213030
1256
51
31 32 33
6 9 10 11 12 8 3
5
4
43 44
24 25
42
18 19 45 27 48 30 36 46 47 26 28 37 15 41 29 14 49 50 34 21 38 5253 22 35 39 40 23 16 17
7 20
4
Salvo error u omisiĂłn
8
12
16 min
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/GC(cromatografía de gas) 1 Optimafi 5 capillary columns for GC
1
5 % phenyl - 95 % dimethylpolysiloxane
MACHEREY-NAGEL
USP G27, G36 nonpolar standard phase with large range of application similar phases: Permabondfi SE-52 , SE-54, SE-52, DB-5, HP-5, SPB-5, CP-Sil 8, Rtx-5, 007-5, BP5, MDN-5, AT-5, ZB-5 for columns with 0.1 to 0.32mm ID and films <3µm the max. temperature for isothermal operation is 340°C, the max. temperature for short isotherms in a temperature programme is 360°C for 0.53mm ID columns with films < 3µm the max. temperatures are 320 and 340°C, resp. for thick film columns with films ≥ 3µm the max. temperatures are 300 and 320°C, resp.
Type
0.10 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.53 0.53 0.53 0.53 0.53 0.53 0.53 0.53 0.53 0.53 0.53
mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm
i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d.
(0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.8 (0.8 (0.8 (0.8 (0.8 (0.8 (0.8 (0.8 (0.8 (0.8 (0.8
mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm
o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.)
Film thickness
Length
PK
µm 0.10 0.10 0.25 0.35 0.50 1.00 0.10 0.25 0.35 0.50 1.00 0.10 0.25 0.35 0.50 1.00 0.10 0.25 0.35 0.50 1.00 0.10 0.25 0.35 0.50 1.00 3.00 5.00 0.10 0.25 0.35 0.50 1.00 3.00 5.00 0.10 0.25 0.35 0.50 1.00 3.00 0.10 0.25 0.35 0.50 1.00 3.00 0.50 1.00 2.00 5.00 0.50 1.00 2.00 5.00 2.00 5.00 2.00
m 10 25 25 25 25 25 30 30 30 30 30 50 50 50 50 50 60 60 60 60 60 25 25 25 25 25 25 25 30 30 30 30 30 30 30 50 50 50 50 50 50 60 60 60 60 60 60 25 25 25 25 30 30 30 30 50 50 60
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Cat. No.
4.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003
235 709 715 719 723 727 710 716 720 724 728 711 717 721 725 729 712 718 722 726 730 733 738 742 746 751 755 760 734 739 743 747 752 756 761 735 740 744 748 753 757 736 741 745 749 754 758 155 168 158 261 156 169 159 262 160 263 161
In addition to this standard programme we will be happy to supply columns custom-made to your specifications. Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen. Additionally, we supply the corresponding test mixture with each column.
Salvo error u omisión
1257
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/GC(cromatografĂa de gas) 1 Optimafi 5 MS capillary columns for GC 5 % diphenyl - 95 % dimethylpolysiloxane
1
MACHEREY-NAGEL
USP G36 nonpolar phase with low bleeding ideal for GC/MS and ECD applications and general analyses at trace level perfect inertness for basic compounds similar phases: DB-5 MS, HP-5 MS, Ultra-2, Equity-5, CP-Sil 8 CB low bleed/MS, Rtx-5SIL-MS, Rtx-5 MS, 007-5 MS, BPX5, MDN-5S, AT-5 MS, VF-5 MS max. temperature for isothermal operation: 340°C, max. temperature for short isotherms in a temperature programme: 360°C
Type
0.25 0.25 0.25 0.25 0.25 0.32 0.32 0.32 0.32 0.32
mm mm mm mm mm mm mm mm mm mm
i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d.
(0.4 (0.4 (0.4 (0.4 (0.4 (0.5 (0.5 (0.5 (0.5 (0.5
mm mm mm mm mm mm mm mm mm mm
o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.)
Film thickness
Length
PK
Âľm 0.25 0.50 1.00 0.25 0.50 1.00 0.25 0.50 1.00 1.00
m 30 30 30 60 60 25 30 30 50 60
1 1 1 1 1 1 1 1 1 1
Cat. No.
7.080 4.003 4.003 4.003 4.003 4.003 6.700 4.003 4.003 7.080
092 099 101 098 100 091 690 093 092 742
In addition to this standard programme we will be happy to supply columns custom-made to your specifications.
12
Analysis of various phenols OPTIMAÂŽ 5 MS, 30 m x 0.25 mm ID, Â&#x2014;P Âż OP PD[ WHPSHUDWXUH Â&#x192;& Sample: 5 ppm each except N-i-propylaniline (9.4 ppm) Method: SPME Temperature: 40 °C (2 min) A 240 °C, 6 °C/min A 320 °C, 20 °C/min Detector: MSD Peaks: 1. Toluene-D8 2. Phenol 3. 2-Methylphenol (o-Cresol) 4. Nitrobenzene-D5 5. N-i-Propylaniline 6. 2,4-Dichlorophenol 7. 4-Chlorophenol 8. 4-Bromo-2-chlorophenol 9. 3-Bromophenol 10. 4-Chloro-3-methylphenol 11. 2,4-Dibromophenol 12. 2-Hydroxybiphenyl 13. 2-Cyclohexylphenol +H[DĂ&#x20AC; XRURELVSKHQRO $ Column:
8
10 5
9
7 1
34
13
2 6
courtesy of Riedel-de-HaĂŤn, Seelze, Germany MN Appl. No. 210110
Salvo error u omisiĂłn
14
10
11 20
30
min
1259
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/GC(cromatografĂa de gas) 1 Optimafi 5 MS Accent capillary columns for GC
1
MACHEREY-NAGEL
silarylene phase with polarity similar to a 5 % diphenyl -95 % dimethylpolysiloxane phase. USP G27, G36
lowest column bleed, nonpolar phase, ideal for ion trap and quadrupol MS detectors solvent rinsing for removal of impurities applicable application areas: all-round phase for environmental analyses, trace analyses, EPA methods, pesticides, PCB, food and drug analyses similar phases: DB-5 MS, HP-5 MS, Ultra-2, Equity-5, CP-Sil 8 CB low bleed/MS, Rtx-5SIL-MS, Rtx-5 MS, 007-5 MS, BPX5, MDN-5S, AT-5 MS, VF-5 MS max. temperature for isothermal operation: 340°C, max. temperature for short isotherms in a temperature programme: 360°C Type
0.25 0.25 0.25 0.25 0.25 0.25 0.32 0.32 0.32 0.32 0.32
mm mm mm mm mm mm mm mm mm mm mm
i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d.
(0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.5 (0.5 (0.5 (0.5 (0.5
mm mm mm mm mm mm mm mm mm mm mm
Film thickness
Length
PK
Âľm 0.25 0.50 1.00 0.25 0.50 1.00 1.00 0.25 0.50 0.25 1.00
m 30 30 30 60 60 60 25 30 30 60 60
1 1 1 1 1 1 1 1 1 1 1
o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.)
Cat. No.
4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003
017 019 021 018 020 022 011 009 013 010 012
Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen. Additionally, we supply the corresponding test mixture with each column.
7KH EOHHG FRPSDULVRQ WHVW RI WKH 237,0$ÂŽ 5-MS Accent with a conventional 5-MS phase shows the outstanding performance of the silarylene phase.
7KH XQPDWFKHG ORZ EDFNJURXQG OHYHO RI WKH 237,0$ÂŽ 5 MS Accent, which is approximately three times lower FRPSDUHG WR D 06 EUDQG FROXPQ SURYLGHV VLJQLÂż FDQWO\ increased sensitivity and allows the application in trace analyses particularly of high-boiling compounds.
Background noise at 340 °C
FID Signal in mV
107.8
90.2
Standard 5 MS Phase 107.6
90
107.4
89.8
107.2
89.6
0
1260
10
20
30 s
0
Salvo error u omisiĂłn
OPTIMAÂŽ 5 MS Accent 10
20
30 s
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/GC(cromatografĂa de gas) 1 Optimafi 17 capillary columns for GC phenylmethylpolysiloxane (50 % phenyl)
MACHEREY-NAGEL
1
USP G3 medium polar phase suitable for higher temperatures preferred applications: steroids, pesticides, drug analyses similar phases: OV-17, DB-17, HP50+, HP17, SPB-50, SP-2250, Rtx-50, CP-Sil 24 CB, 007-17, ZB50 max.temperature for isothermal operation: 320°C, max. temperature for short isotherms in a temperature programme: 340°C, for 0.53mm ID columns the max. temperatures are 300 and 320°C, resp.
Type
0.10 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.53 0.53
mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm
i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d.
(0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.4 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.8 (0.8
mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm
Film thickness
Length
PK
Âľm 0.10 0.15 0.25 0.50 0.15 0.25 0.50 0.15 0.25 0.50 0.15 0.25 0.50 0.25 0.35 0.50 0.15 0.25 0.35 0.50 0.25 0.35 0.50 0.25 0.35 0.50 1.00 1.00
m 10 25 25 25 30 30 30 50 50 50 60 60 60 25 25 25 30 30 30 30 50 50 50 60 60 60 25 30
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.)
Cat. No.
4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003
236 181 026 046 182 027 047 183 028 048 184 029 049 112 194 185 193 113 195 186 114 196 187 115 197 188 191 192
In addition to this standard programme we will be happy to supply columns custom-made to your specifications.
1
Analysis of pesticides Column: Sample: Inj. volume: Carrier gas: Temperature: Detector:
2
5
10
OPTIMAÂŽ Â&#x2014;P Âż OP 25 m x 0.20 mm ID, max. temperature 320/340 °C, pesticide standard of the cantonal laboratory Schaffhausen (Switzerland), 0.1 mg/ml or 0.01 mg/ml each 1.0 Âľl He, 25 cm/s, 3 s without split 100 °C (3 min), 8 °C/min A 250 °C, 10 °C/min A 320 °C MSD HP 5971 MN Appl. No. 200930
13
34 6 7 89
10
Salvo error u omisiĂłn
20
1112
Peaks: 1. Dichlorphos 2. Naled 3. Vinclozolin 4. Chlorthalonil 5. Chlorpyrifos 'LFKORĂ&#x20AC; XDQLG 7. Procymidon 8. Captan 9. Folpet 10. Carbophenothion 11. Iprodion 12. Captafol 13. Coumaphos
30 min
1261
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/GC(cromatografĂa de gas) 1 Optimafi 1701 capillary columns for GC
1
14 % Cyanopropyl-phenyl - 86 % Dimethylpolysiloxane
MACHEREY-NAGEL
USP G46 medium polar phase special selectivity due to high cyanopropyl content reference column for structure identification, e.g. in combination with Optima 5 film thickness ? 1 ¾m for solvent analyses similar phases: OV-1701, DB-1701, CP?Sil 19 CB, HP-1701, Rtx-1701, SPB-1701, 007-1701, BP10, ZB-1701 max. temperature for isothermal operation: 300°C, max. temperature for short isotherms in a temperature programme: 320°C for 0.53mm ID columns the max. temperatures are 280 and 300°C, resp.
Type
0.25 mm i.d. (0.4 mm o.d.) 0.25 mm i.d. (0.4 mm o.d.) 0.25 mm i.d. (0.4 mm o.d.) 0.25 mm i.d. (0.4 mm o.d.) 0.25 mm i.d. (0.4 mm o.d.) 0.25 mm i.d. (0.4 mm o.d.) 0.25 mm i.d. (0.4 mm o.d.) 0.32.mm i.d. (0.5 mm o.d.) 0.32.mm i.d. (0.5 mm o.d.) 0.32.mm i.d. (0.5 mm o.d.) 0.32.mm i.d. (0.5 mm o.d.) 0.32.mm i.d. (0.5 mm o.d.) 0.32.mm i.d. (0.5 mm o.d.) 0.32.mm i.d. (0.5 mm o.d.) 0.32.mm i.d. (0.5 mm o.d.) 0.32.mm i.d. (0.5 mm o.d.) 0.32.mm i.d. (0.5 mm o.d.) 0.32.mm i.d. (0.5 mm o.d.) 0.32.mm i.d. (0.5 mm o.d.) 0.32.mm i.d. (0.5 mm o.d.) 0.32.mm i.d. (0.5 mm o.d.) 0.32.mm i.d. (0.5 mm o.d.) 0.32.mm i.d. (0.5 mm o.d.) 0.53 mm i.d. (0.8 mm o.d.) 0.53 mm i.d. (0.8 mm o.d.) 0.53 mm i.d. (0.8 mm o.d.) 0.53 mm i.d. (0.8 mm o.d.) 0.53 mm i.d. (0.8 mm o.d.)
Film thickness
Length
PK
Âľm 0.25 0.25 0.50 1.00 0.25 0.25 0.50 0.25 0.35 0.50 1.00 0.25 0.35 0.50 1.00 0.25 0.35 1.00 1.00 0.25 0.35 0.50 1.00 1.00 2.00 1.00 2.00 2.00
m 25 30 30 30 50 60 60 25 25 25 25 30 30 30 30 50 50 50 50 60 60 60 60 25 25 30 30 50
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Cat. No.
4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003 7.088 4.003 4.003 4.003 4.003 4.003 4.003
035 036 039 272 037 038 040 103 222 107 268 104 223 108 269 105 224 109 270 106 225 327 271 172 178 173 179 180
In addition to this standard programme we will be happy to supply columns custom-made to your specifications.
2
Analysis of aromatic hydrocarbons Column: ,QM YROXPH &DUULHU JDV Split: Temperature: Detector: Peaks: 1. Benzene 2. Toluene (WK\OEHQ]HQH 4. p-Xylene 5. o-Xylene 6. Phenol
1262
OPTIMAÂŽ Â&#x2014;P Âż OP P [ PP ,' PD[ WHPS Â&#x192;& Â&#x2014;O EDU 12 1:40 60 °C A Â&#x192;& Â&#x192;& PLQ FID 260 °C
6 7
1 4
9 3
5
7. 2-Methylphenol 8. 2,6-Dimethylphenol 9. 4-Methylphenol 10. 2,4-Dimethylphenol 11. 2,4,6-Trimethylphenol
8
01 $SSO 1R
Salvo error u omisiĂłn
0
5
10
10 11
15 min
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/GC(cromatografía de gas) 1 Optimafi 624 capillary columns for GC
1
6 % cyanopropyl-phenyl - 94 % dimethylpolysiloxane
MACHEREY-NAGEL
USP G43 medium polar phase recommended for environmental analyses similar phases: HP-624, HP-VOC, DB-624, DB-VRX, SPB-624, CP-624, Rtx-624, Rtx-Volatiles, 007-624, BP624, VOCOL max. temperature for isothermal operation: 280°C, max. temperature for short isotherms in a temperature programme: 300°C Type
0.25 0.25 0.25 0.32 0.32 0.32 0.53 0.53
mm mm mm mm mm mm mm mm
i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d.
(0.4 (0.4 (0.4 (0.5 (0.5 (0.5 (0.8 (0.8
mm mm mm mm mm mm mm mm
Film thickness
Length
PK
µm 1.40 1.40 1.40 1.80 1.80 1.80 3.00 3.00
m 30 50 60 30 50 60 25 30
1 1 1 1 1 1 1 1
o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.)
Cat. No.
4.003 4.003 4.003 4.003 4.003 4.003 4.003 4.003
211 212 213 217 218 219 220 221
In addition to this standard programme we will be happy to supply columns custom-made to your specifications.
2 Optimafi 624 LB capillary columns for GC
2
6 % cyanopropyl-phenyl - 94 % dimethylpolysiloxane
MACHEREY-NAGEL
USP G 43 medium polar phase low bleed columns for halogenated hydrocarbons, volatiles, aromatic compounds, solvents etc. similar phases: HP-624, HP-VOC, DB-624, DB-VRX, SPB-624, CP-624, Rtx-624, Rtx-Volatiles, 007-624, BP624, VOCOL max. temperature for isothermal operation: 280°C, max. temperature for short isotherms in a temperature programme: 300°C
Type
0.32 mm i.d. (0.5 mm o.d.) 0.32 mm i.d. (0.5 mm o.d.)
Film thickness
Length
PK
Cat. No.
µm 1.80 1.80
m 30 50
1 1
4.003 214 4.003 215
In addition to this standard programme we will be happy to supply columns custom-made to your specifications.
Salvo error u omisión
1263
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/GC(cromatografĂa de gas) Solvents and semi-volatiles Column: Carrier gas: 7HPSHUDWXUH ,QMHFWLRQ Detection:
OPTIMAÂŽ 624 LB Â&#x2014;P Âż OP P [ PP ,' 5HWHQWLRQ *DS 3KH 6LO P [ PP 1.1 bar He 15 17 1 Â&#x192;& PLQ A Â&#x192;& Â&#x192;& PLQ A 14 Â&#x192;& Â&#x192;& PLQ PLQ Â&#x192;& Â&#x2014;O SSP SHU VXEVWDQFH LQ DFHWRQH 8 cold on-column 16 13 FID 280 °C
Peaks:
1. Acetone 2. Ethyl acetate 3. Tetrahydrofuran 4. Cyclohexane 0HWK\O EXWDQRO 6. Butanol-1 7. Pyridine 8. Toluene 9. Dimethylformamide 10. Dimethylsulphoxide
11. Decane 12. Octanol-1 13. Acetophenone 14. Butyrophenone +HSWDQRSKHQRQH 0HWKR[\ LQGROH 17. Dibenzylamine 18. Methyl eicosanoate 19. Methyl cis-13-docosenoate 20. Methyl docosanoate
7
2
45 3 6
01 $SSO 1R 0
11 12
18
19 20
9 10
10
20
30
40 min
1 OPTIMAfi 225 capillary columns for GC
1
MACHEREY-NAGEL
50 % cyanopropylmethyl - 50 % phenylmethylpolysiloxane USP G7/G19 middle polar phase recommended for fatty acid analyses similar phases: DB-225, HP-225, OV-225, Rtx-225, CP-Sil 43, 007-225, BP225 max. temperature for isothermal operation: 260°C, max. temperature for short isotherms in a temperature programme: 280°C Type
0.10 0.25 0.25 0.25 0.32 0.32 0.32
mm mm mm mm mm mm mm
i.d. i.d. i.d. i.d. i.d. i.d. i.d.
(0.4 (0.4 (0.4 (0.4 (0.5 (0.5 (0.5
mm mm mm mm mm mm mm
Film thickness
Length
PK
Âľm 0.10 0.25 0.25 0.25 0.25 0.25 0.25
m 10 30 50 60 30 50 60
1 1 1 1 1 1 1
o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.)
In addition to this standard programme we will be happy to supply columns custom-made to your specifications.
Analysis of FAME in porcine fat Column: Carrier gas: Temperature: Detector: Peaks: 1. C4:0 2. C5:0 3. C6:0 4. C8:0 5. C10:0 6. C11:0 7. C12:0 8. C13:0 9. C13:1 10. C14:0 11. C14:1 12. C15:0 13. C15:1 14. C16:0 15. C16:1 16. C17:0 17. C17:1
OPTIMAÂŽ Â&#x2014;P Âż OP P [ PP ,' PD[ WHPSHUDWXUH Â&#x192;& 60 kPa H2, injection volume 1 Âľl, split 1:40 50 °C (2 min) A 125 °C, 30 °C/min A 160 °C, 5 °C/min A 180 °C, 20 °C/min A 200 °C, 3 °C/min A 220 °C, 20 °C/min (10 min) FID 260 °C FAME in porcine fat FAME standard 7 8 10 14 15 20 14 18 20 18. C18:0 19 18 19. C18:1 19 20. C18:2 21. C18:3 8 22. C19:0 23. C20:0 24. C20:1 25. C20:2 26. C20:4 27. C20:3 28. C20:5 24 16 29. C22:0 25 30. C22:1 15 12 31. C22:2 22 32. C22:6 21 10 33. C24:0 22 34. C24:1 3 4
courtesy of Dr. Bantleon, Mr. Leusche, Mr. Hagemann, VFG-Labor, Versmold, Germany MN Appl. No. 210060
1264
2
5
6
9 1113 17
1
28 30 23 26 3132 27 29 3334
24 2 5
0
10
20
min
Salvo error u omisiĂłn
0
7
1112 10
16 17
21
25 23 26 27 20
32 min
Cat. No.
4.003 4.003 4.003 4.003 4.003 4.003 4.003
050 066 067 068 117 118 119
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/GC(cromatografĂa de gas)
1 Optimafi WAX capillary columns for GC
1
polyethylene glycol 20000 daltons
MACHEREY-NAGEL
USP G16 polar phase recommended for solvent analysis and alcohols suitable for aqueous solutions similar phases: Premabondfi CW 20 M , DB-Wax, Supelcowax, HP-Wax, HP-INNOWAX, Rtx-Wax, CP-Wax 52 CB, Stabilwax, 007-CW, BP20, AT-Wax, ZB-Wax max. temperature for isothermal operation 250°C, max. temperature for short isotherms in a temperature programme: 260°C, for 0.53 mm ID columns the max. temperatures are 220 and 240°C, resp.
Type
0.25 0.25 0.25 0.25 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.53 0.53 0.53
mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm
i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d.
(0.4 (0.4 (0.4 (0.4 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.8 (0.8 (0.8
mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm
o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.)
Film thickness
Length
PK
Âľm 0.25 0.25 0.25 0.25 0.25 0.50 0.25 0.50 0.25 0.50 0.25 0.50 1.00 1.00 2.00
m 25 30 50 60 25 25 30 30 50 50 60 60 25 30 30
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Cat. No.
9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 4.003 4.003 4.003
762 763 764 765 766 770 767 771 768 772 769 773 175 176 174
In addition to this standard programme we will be happy to supply columns custom-made to your specifications.
0RGLÂż HG *URE WHVW Column: Inj. volume: Carrier gas: Split: Temperature:
OPTIMAÂŽ :$; Â&#x2014;P Âż OP P [ PP ,' PD[ WHPSHUDWXUH Â&#x192;& 1 Âľl 1,2 bar He 1 1:20 3 2 80 °C Î&#x; 250 °C, 4 Â&#x192;& PLQ FID 250 °C
Detector: Peaks: 1. Decane 2. Undecane 3. Octanol 4. Methyl decanoate 5. Dicyclohexylamine 6. Methyl undecanoate 7. Methyl dodecanoate 8. 2,6-Dimethylaniline 9. 2,6-Dimethylphenol
MN Appl. No. 211170
0
5
Salvo error u omisiĂłn
10
15
6 5
7
89
20
min
1265
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/GC(cromatografĂa de gas) 1 Optimafi FFAP capillary columns for GC
1
polyethylene glycol 2-nitroterephthalate
MACHEREY-NAGEL
close equivalent USP G25/G35 polar phase recommended for FAME, free carboxylic acids similar phases: Permabond FFAP , DB-FFAP, HP-FFAP, CP-Sil 58 CB, 007-FFAP, CP-FFAP CB, Nukol for columns with 0.10 to 0.32mm ID the max. temperature for isothermal operation is 250°C, the max. temperature for short isotherms in a temperature programme is 260°C for 0.53mm ID columns the max. temperatures are 220 and 240°C, resp. Type
0.10 0.25 0.25 0.25 0.25 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.53 0.53
mm mm mm mm mm mm mm mm mm mm mm mm mm mm
i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d. i.d.
(0.4 (0.4 (0.4 (0.4 (0.4 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.5 (0.8 (0.8
mm mm mm mm mm mm mm mm mm mm mm mm mm mm
Film thickness
Length
PK
Âľm 0.10 0.25 0.25 0.25 0.25 0.25 0.50 0.25 0.50 0.25 0.50 0.25 1.00 0.50
m 10 25 30 50 60 25 25 30 30 50 50 60 25 30
1 1 1 1 1 1 1 1 1 1 1 1 1 1
o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.) o.d.)
Cat. No.
4.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 9.003 4.003 4.003
079 774 775 776 777 778 782 779 783 780 784 781 111 110
In addition to this standard programme we will be happy to supply columns custom-made to your specifications. Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen. Additionally, we supply the corresponding test mixture with each column.
FAME test Column: Carrier gas: Temperature:
OPTIMAÂŽ ))$3 Â&#x2014;P Âż OP P [ PP ,' PD[ WHPSHUDWXUH Â&#x192;& 1.2 bar He, split 55 °C Î&#x; 250 °C, 6 °C/min 1,0 Âľl, 220 °C 2 FID 220 °C 3
Injection: Detector: Peaks: 1. C4 2. C6 3. C8 4. C10 5. C12 6. C14 7. C16 8. C18 9. C18:1 cis/trans 10. C18:2 11. C18:3 12. C20 13. C22 14. C22:1 15. C24
MN Appl. No. 211140
4
5
1
9 6
7 8
11 10 12 13 14
0
10
20
30
40
50
15
60 min
Optimafi 5 Amine GC capillary columns for amine separation especially deactivated for the analysis of polyfunctional amines such as ethanolamines, amino-functionalised diols and similar compounds, which are important base materials in industrial chemistry, and shows strong tailing on standard-deactivated columns similar phases: Rtx-5 Amine, PTA-5
MACHEREY-NAGEL
USP G27/G36 improved linearity for analyses of active components at trace levels: no amine absorptions even for aliphatic and aromatic amines at concentrations of 100 pg/peak tested with the Optimafi Amine test mixture, which among others also contains diethanolamine and propanol-pyridine (this test mixture is supplied with each column) max. temperature for isothermal operation: 300°C, max. temperature for short isotherms in a temperature programme: 320°C Type
0.25 mm i.d. (0.4 mm o.d.) 0.25 mm i.d. (0.4 mm o.d.) 0.32 mm i.d. (0.5 mm o.d.)
1266
Film thickness
Length
PK
Cat. No.
Âľm 0.50 1.00 0.25
m 30 30 30
1 1 1
6.900 659 4.003 123 4.003 125
Salvo error u omisiĂłn
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/GC(cromatografĂa de gas)
Separation of secondary and tertiary amines Column: OPTIMAÂŽ $PLQH Â&#x2014;P Âż OP P [ PP ,' PD[ WHPSHUDWXUH Â&#x192;& Injection volume: 1 Âľl 2 Carrier gas: 0,6 bar H2, Split 1:100 3 6 Temperature: 100 °C (3 min) A 280 °C, 10 °C/min 5 7 8 'HWHFWRU ),' Â&#x192;& 1 4 Peaks: 'LHWK\ODPLQH 'L LVREXW\ODPLQH 'L LVRSURS\ODPLQH 8. Tri-n-butylamine 3. Triethylamine 'L LVRKH[\ODPLQH 'L n-propylamine 'LF\FORKH[\ODPLQH 'L n-butylamine 'LEHQ]\ODPLQH 6. Tri-n-propylamine 12. Tri-n-hexylamine 0
MN Appl. No. 210280
9
10
12 11
10
20 min
Capillary columns for special separations LIPODEXÂŽ cyclodextrin phase for enantiomer separation
MACHEREY-NAGEL
base material: cyclic oligosaccharide consisting of eight glucose units bonded through Îą-1.4-linkages (y-cylodextrin) regioselective alkylation and acylation of the hydroxyl groups leads to a lipophilic phase, which is well suited for GC enantiomer analyses important advantage: many compounds can be analysed without derivatisation (however, for certain substances enantioselectivity can be favourably influenced by formation of derivatives) A large number of separations have been achieved, however, it is not possible to make gerneral predictions. Even for compounds with small structural differences or within a homologous series the enantiodifferentia-tion can be quite different. LIPODEX fi is patented under EP 0407 412 and US Re. 36.092
Lipodexfi E ¡ octakis-(2.6-di-O-pentyl-3-O-butyryl)-γ-cyclodextrin recommended for ι-amino acids, ι- and β-hydroxycarboxylic acid esters, alcohols (TFA), diols (TFA), ketones, pheromones (cyclic acetals), amines, alkyl halides, lactones
MACHEREY-NAGEL
max. temperature for isothermal operation: 200°C, max. temperature for short isotherms in a temperature programme: 220°C Tipo
Ă&#x2DC;
FS-LIPODEXfi E FS-LIPODEXfi E
0.25 mm i.d. (0.4 mm o.d.) 0.25 mm i.d. (0.4 mm o.d.)
Longitud m 25 50
ud.E
CĂłdigo
1 1
4.002 925 4.002 926
Enantiomer separation of amino acid methyl esters (TFA) &ROXPQ
)6 /,32'(;ÂŽ ( P [ PP ,' PD[ WHPS Â&#x192;& Â&#x2014;O N3D + a A Â&#x192;& Â&#x192;& PLQ ),' Â&#x192;& $7
9ROXPH &DUULHU JDV 6SOLW 7HPSHUDWXUH 'HWHFWRU Peaks: ' LV HOXWHG EHIRUH / H[FHSW IRU SUROLQH / EHIRUH '
$ODQLQH 9DOLQH /HXFLQH 3UROLQH $VSDUWLF DFLG 3KHQ\ODODQLQH
01 $SSO 1R
2
1
3
6
4 5
0
10
Salvo error u omisiĂłn
20 min
1267
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/GC(cromatografĂa de gas) HYDRODEX cyclodextrin phases for enantiomer separation cyclodextrin derivatives with high melting point: for GC-enantiomer separation diluted with polysiloxanes
MACHEREY-NAGEL
heptakis-(2.3-di-O-methyl-6-O-t-butyldimethyl-silyl)-β-cyclodextrin phase diluted with optimised polysiloxane recommended for γ-lactones, cyclopentanones, terpenes, esters, tartrates
MACHEREY-NAGEL
max. temperature for isothermal operation: 230°C, max. temperature for short isotherms in a temperature programme: 250°C Type
Diam.
FS- HYDRODEX βâ&#x2C6;&#x2019; 6 TBDM FS- HYDRODEX βâ&#x2C6;&#x2019; 6 TBDM
0.25 mm i.d. (0.4 mm o.d.) 0.25 mm i.d. (0.4 mm o.d.)
Length m 25 50
PK
Cat. No.
1 1
4.002 931 4.002 932
heptakis-(2.3-di-O-acetyl-6-O-t-butyldimethyl-silyl)-β-cyclodextrin all columns 0.25 mm ID, 0.4 mm OD
MACHEREY-NAGEL
phase diluted with optimised polysiloxane recommended for alcohols, esters, ketones, aldehydes, δ-lactones max. temperature for isothermal operation: 220°C, max. temperature for short isotherms in a temperature programme: 240°C Type
Diam.
FS-HYDRODEX β-TBDAC FS-HYDRODEX β-TBDAC
0.25 mm i.d. (0.4 mm o.d.) 0.25 mm i.d. (0.4 mm o.d.)
Length m 25 50
6HSDUDWLRQ RI LVRPHULF DQWLLQĂ&#x20AC; DPPDWRU\ GUXJV &RXUWHV\ RI 3URI : $ .|QLJ +DPEXUJ *HUPDQ\ &ROXPQ +<'52'(; ` 7%'0 P [ PP ,' max. temperature 250 °C &DUULHU JDV +H 7HPSHUDWXUH Â&#x192;& A Â&#x192;& Â&#x192;& PLQ 'HWHFWRU ),' Peaks: ,EXSURIHQ )OXUELSURIHQ )HQRSURIHQ 4. Naproxen 5. Ketoprofen
2
10
Cat. No.
1 1
4.002 935 4.002 936
6HSDUDWLRQ RI 5 6 FLWURQHOORO FLWURQHOODO &ROXPQ
)6 +<'52'(; ` 7%'$F P [ PP ,' PD[ WHPSHUDWXUH Â&#x192;& EDU +2 VSOLW PO PLQ Â&#x192;& Â&#x2014;O LQ &+2Cl2 ),' Â&#x192;&
&DUULHU JDV 7HPSHUDWXUH ,QMHFWLRQ 'HWHFWRU Peaks: 5 6 &LWURQHOODO 6 5 &LWURQHOODO 6 &LWURQHOORO 5 &LWURQHOORO
O
3 1 SR
PK
1
OH
3
4
2
4 5
15
20
30
40
50 min 0
01 $SSO 1R
10
20
30
min
01 $SSO 1R
Reagents and methods for derivatisation Derivatisation reagents
MACHEREY-NAGEL
for improved volatility, better thermal stability or low limit of detection in gas chromatography prerequisite: quantitative, rapid and reproducible formation of only on derivative halogen atoms introduced by derivatisation (e.g. trifluoroacetates) allow specific detection (ECD) with the advantage of high sensitivity elution order and fragmentation patterns in MS can be influenced by a specific derivatisation reagents for silylation - alkylation (methylation) - acylation are available
1268
Salvo error u omisiĂłn
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/GC(cromatografía de gas) Selection guide for derivatisation of important functional groups in GC Function
method
derivative
recommended reagents
silylation acylation alkylation
R’O – TMS R’O – CO – R R’O – R
MSTFA HFBA, MBTFA TMSH
R’O – TMS R’ – NR’’ – TMS R’ – NR’’ – CO – R R’ – NR’’ – TMS not stable
BSTFA, SILYL-991 MSTFA, SILYL-991 HFBA, MBTFA MSTFA
Amides
silylation silylation acylation silylation silylation
Amino acids
acylation silylation
R’ – CO – NH – CO – R R’ – CH(NH – TMS) – CO – O – TMS
MBTFA, HFBA BSTFA, MSTFA
R’ – CH(NH – CO – R) – CO – O – R
Carboxylic acids
alkylation (a) + acylation (b) silylation
a) TMSH b) HFBA, MBTFA MSTFA
Alcohols, phenols R’OH sterically hindered
Amines primary, secondary hydrochlorides
R’ – CO – O – TMS susceptible to hydrolysis
(fatty acids)
Carbohydrates
alkylation silylation
Steroids
acylation acylation
R’ – CO – O – R
TMSH MSTFA MBTFA MBTFA, HFBA
Derivatisation method development kit MACHEREY-NAGEL
Which type of derivatisation is best suited for your sample (alkylation, acylation or silylation)? Contents of the kit 2 x 1 ml each of TMSH, MSTFA, MBTFA
PK
Cat. No.
1
4.001 514
Acylation kit Which is the proper reagent for acylation?
MACHEREY-NAGEL
Contents of the kit 2 x 1 ml each for MBTFA , TFAA, MBHFBA
PK
Cat. No.
1
6.207 118
Alkylation kit MACHEREY-NAGEL
Which is the proper reagent for methylation? Contents of the kit 3 x 1 ml each for TMSH, DMF-DMA
PK
Cat. No.
1
4.001 513
Silylation kit MACHEREY-NAGEL
Which is the proper reagent for silylation? Contents of the kit 2 x 1 ml each for MSTFA, BSTFA, TSIM, MSHFBA
PK
Cat. No.
1
6.704 458
Acylation reagents for GC - Anhydrides MACHEREY-NAGEL by-products of acylation with anhydrides: corresponding acids excess reagent and the acid formed have to be removed Acylation with fluorinated acid anhydrides can be used for alcohols, phenols, carboxylic acids, amines, amino acids and steroids forming volatile, stable derivatives suited for FID as well as for ECD detection. Heptafluorobutyric acid anhydride (HFBA) m.w. 410.06, Bp 106 - 107°C (760 mm Hg), C3F7 - CO - O - CO - C3F7 density d20°/4° = 1.665
Code
Capacity
PK
Cat. No.
HFBA HFBA HFBA
20 x 1 ml 1 x 10 ml 5 x 10 ml
20 1 5
4.001 480 4.001 479 4.001 481
Salvo error u omisión
1269
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/GC(cromatografĂa de gas)
Methods for acylation $F\ODWLRQ ZLWK Ă&#x20AC; XRULQDWHG DFLG DQK\GULGHV
$F\ODWLRQ ZLWK Ă&#x20AC; XRULQDWHG DFLG DPLGHV
Acylation with HFBA can be used for alcohols, phenols, carboxylic acids, amines, amino acids and steroids forming volatile, stable derivatives suited for FID as well as for ECD detection.
This method is recommended for alcohols, primary and secondary amines as well as thiols under mild, neutral conditions. MBTFA also forms very volatile derivatives with carbohydrates [J. Sullivan and L. Schewe, J. Chromatogr. Sci. 15 (1977) 196 â&#x20AC;&#x201C; 197].
Procedure: Dissolve 0.1 to 1 mg of the sample in 0.1 ml solvent, add 0.1 ml HFBA and heat to 60 â&#x20AC;&#x201C; 70 °C for 1 â&#x20AC;&#x201C; 2 hours. If the sample need not be concentrated prior to the analysis and if there is no danger of catalytically induced side reactions, pyridine is used as solvent. The reaction solution can be injected directly into the gas chromatograph. Otherwise use a volatile solvent and evaporate solvent, excess derivatisation reagent and free acid in a stream of nitrogen. Dissolve the residue in 50 Âľl hexane, chloroform etc. and inject aliquot portions.
Procedure: Add 0.5 ml MBTFA to about 2 mg sample. If there is no reaction at ambient temperature, heat the reaction PL[WXUH WR Â&#x192;& &RPSRXQGV ZKLFK DUH GLIÂż FXOW WR GLVVROYH FDQ EH WULĂ&#x20AC; XRUDFHW\ODWHG LQ VXLWDEOH VROYHQW mixtures. It is recommended to use a ratio of solvent to MBTFA of 4 : 1. The reaction mixture can be chromatographed directly.
MN Appl. No. 213042
MN Appl. No. 213051
Acylation reagents for GC - Bisacylamides by-products: corresponding neutral acylamides, which can be easily removed due to MACHEREY-NAGEL their high volatility; because of neutral conditions and favourable chromatographic properties often removal of the bisacylamide is not necessary. Thus sample preparation is much more convenient. Acylation with fluorinated acid amides is recommended for alcohols, primary and secondary amines as well as for thiols under mild, neutral conditions. MBTFA also forms very volatile derivatives with carbohydrates. MBTFA /MBHFBA N-methyl-bis(trifluoroacetamide) MBTFA m.w. 223.08, Bp 123 - 124°C (760 mm Hg), density d20°/4° = 1.55 CF3 - CO - N(CH3) - CO - CF3
Code
Capacity
PK
Cat. No.
MBTFA MBTFA MBTFA
20 x 1 ml 1 x 10 ml 5 x 10 ml
20 1 5
7.401 143 7.510 796 6.228 605
Due to their purpose, derivatisation reagents are very reactive substances. For this reason they should be stored cool and protected from moisture. Our derivatisation reagents are supplied in vials with crimp caps for easy access with a syringe. Vials with pierced sealing disks have limited stability and should be used soon.
Alkylation reagents for GC - Trimethylsulphonium hydroxide TMSH (0.2 M in methanol) M.G. 94.06
MACHEREY-NAGEL
Code
Capacity
PK
Cat. No.
TMSH TMSH TMSH
10 x 1 ml 20 x 1 ml 5 x 10 ml
10 20 5
7.086 147 7.083 308 4.001 512
Silylation reagents Usually the term silylation in GC stands for replacement of active hydrogen atoms by a MACHEREY-NAGEL trimethylsilyl group (TMS derivative). Sometimes, however, trialkylsilyl groups or dimethylalkylsilyl groups with longer alkyl chains are used for derivatisation. The trialkylsilyl group increases volatility and enhances thermal stability of the sample. Silylation can be catalysed either acidic by addition of TMCS or basic by addition of pyridine (e. g. for sterically hindered functionalities like tert. alcohols)
1270
Salvo error u omisiĂłn
14. CromatografĂa
GENERAL CATALOGUE 2010/11
Columnas para cromatografĂa/GC(cromatografĂa de gas) Silylation reagents - BSTFA, SILYL-991 MACHEREY-NAGEL N,O-bis-trimethylsilyl-trifluoroacetamide m.w. 257.4, Bp 40°C (12 mm Hg), density d20°/4° = 0.961 BSTFA: R = CF3 powerful trimethylsilyl donor with approximately the same donor strength as the non-fluorinated analogue BSA advantage of BSTFA over BSA: greater volatility of its reaction products (particularly useful for GC of some lower boiling TMS amino acids. BSTFA is nonpolar (less polar than MSTFA), and can be mixed with acetonitrile for improved solubility. For silylating fatty acid amides, hindered hydroxyls and other compounds, which are difficult to silylate (like secondary alcohols and amines), we recommend BSTFA + 1 % trimethylchlorosilane (TMCS), available under the designation SILYL-991. Description BSTFA BSTFA BSTFA SILYL-991 (BSTFA - TMCS (99:1) SILYL-991 (BSTFA - TMCS (99:1) SILYL-991 (BSTFA - TMCS (99:1)
Capacity ml 1 10 10 1 50 100
PK 20 1 5 1 1 1
Cat. No. 4.001 6.803 4.001 4.001 4.001 4.001
486 320 487 511 510 509
Due to their purpose, derivatisation reagents are very reactive substances. For this reason they should be stored cool and protected from moisture. Our derivatisation reagents are supplied in vials with crimp caps for easy access with a syringe. Vials with pierced sealing disks have limited stability and should be used soon.
6LO\ODWLRQ ZLWK %67)$ RU 6,/</ %67)$ 70&6 Procedure: Add 0.5 ml silylation reagent to 1 â&#x20AC;&#x201C; 10 mg sample; if necessary, add some solvent (normally pyridine or DMF [dimethylformamide] are used). Heat to 60 â&#x20AC;&#x201C; 80 °C for 20 min to increase the reaction rate. BSTFA MN Appl. No. 213092 ¡ SILYL-991 MN Appl. No. 213093
1 Silylation reagents - MSTFA
1
N-methyl-N-trimethylsilyl-trifluoroacetamide MACHEREY-NAGEL m.w. 199.1, Bp 70°C (75 mm Hg), density d20°/4° = 1.11 MSTFA: R' = CF3, R" = CH3 the most volatile trimethylsilyl amide available very strong TMS donor which does not cause any noticeable FID fouling even after long-time measuring series The already good solution characteristics can be improved by addition of submolar quantities of protic solvents (e.g. TFA for extremely polar compounds such as hydrochlorides) or pyridine (e.g. for carbohydrates). recommended application: carboxylic acids, hydroxy and ketocarboxylic acids, amino acids, amines, alcohols, polyalcohols, sugars, mercaptans and similar compounds with active hydrogen atoms. Even amine hydrochlorides can be silylated directly. advantages: complete reaction with high reaction rates, even without a catalyst (1 to 2% TMCS or TSIM) the by-product of the reaction (N-methyltrifluoroacetamide) features high volatility and short retention time.
Description
PK
MSTFA MSTFA MSTFA MSTFA MSTFA MSTFA MSTFA
20 1 5 1 6 1 1
Cat. No. 7.055 6.704 6.085 6.227 6.227 4.001 4.001
892 091 475 683 450 493 492
Due to their purpose, derivatisation reagents are very reactive substances. For this reason they should be stored cool and protected from moisture. Our derivatisation reagents are supplied in vials with crimp caps for easy access with a syringe. Vials with pierced sealing disks have limited stability and should be used soon.
Silylation with MSTFA Procedure: Dissolve 10 â&#x20AC;&#x201C; 15 mg sample in 0.8 ml solvent, then add 0.2 ml MSTFA. The reaction mixture can be heated to 60 â&#x20AC;&#x201C; 70 °C for up to 1 h and can be analysed directly. If TFA is used as a solvent, proceed as follows [M. Donike, J. Chromatogr. 85 (1973) 1 â&#x20AC;&#x201C; 7]: Dissolve 1 â&#x20AC;&#x201C; 2 mg sample in 100 Âľl TFA. Dropwise add 0.9 ml MSTFA. After cooling the sample can be chromatographed directly. MN Appl. No. 213111
Salvo error u omisiĂłn
1271
14. Cromatografía
GENERAL CATALOGUE 2010/11
Columnas para cromatografía/GC-Cromatografía de capa fina/Placas de microvaloración 1 Columnas para cromatografía
1
Grifo de PTFE. Esmerilado NS 14/23 en la parte superior. Con frita soldada. Porosidad 0. Abertura del cono del grifo: 2,5 mm. Longitud mm 200 300 200
Ø Capacidad int. mm ml 10 15 10 23 15 35
Lenz ud.E
Código
1 1 1
9.025 912 9.025 913 9.025 914
2 Columnas para cromatografía
2
Grifo de PTFE. Esmerilado NS en la parte superior tal como se ha indicado. Incisiones por encima del grifo para alojar un tapón de algodón. Longitud mm 200 400 600
Ø Capacidad int. mm ml 10 15 20 125 30 430
Lenz
Descripción
NS 14 / 23 con adaptador NS 29 / 32 con adaptador NS 29 / 32
1 Medio de intercambio iónico Whatman
DE52 DEAE-celulosa microgranulada prehinchada, 500 g DE52 DEAE-celulosa microgranulada prehinchada, 2 kg DE52 CM-celulosa microgranulad prehinchada, 500 g CF11 polvo fibroso de celulosa para trabajos con columnas, 500 g P11 celulosa seca bifuncional de intercambio de cationes, 100 g P11 celulosa seca bifuncional de intercambio de cationes, 500 g
2
2 Papeles para cromatografía Delgado (0,20 mm) papel de celulosa DEAE con gran capacidad de intercambio aniónico básico con grupos funcionales dietilaminoetilo. Capacidad de intercambio iónico igual a 1,7 µeq/cm2 y flujo de 95 mm/30 minuto. Para el uso en ensayos de transcriptasa reversa y ADN polimerasa.
1272
1 1 1
9.025 932 9.025 934 9.025 936
ud.E
Código
1
9.950 365
1
9.950 366
1
9.950 367
1
9.950 368
1
9.950 369
1
9.950 370
1
Descripción
DE81
Código
Whatman
Medio de intercambio iónico para columnas de cromatografía y separaciones.
Calidad
ud.E
Ø mm 23
Salvo error u omisión
Whatman
ud.E
Código
400
9.950 335
MACHEREY-NAGEL . . . we Meet your Needs
Professional Solutions for HPLC ➢ C18 and C8 Gravity unique base-deactivation for pH extremes
➢ C18
Pyramid
polar endcapped phase
➢ Sphinx
RP
distinct selectivity for aromatic compounds
➢ C18
Isis
exceptional steric selectivity
Products for Solid Phase Extraction ➢ modern polymer resins – HR-X, EASY, PS/DVB copolymers ➢ standard phases – C18ec, SiOH, NH2, . . . ➢ cation / anion exchangers – HR-XC, HR-XA, SA, SB ➢ polar phases – Alox, Diol, Florisil®, . . . ➢ phases for special applications – QuEChERS, PCB, PAH, THC, . . .
Europe's leading SPE manufacturer www.mn-net.com MACHEREY-NAGEL Germany · USA · Switzerland · France
e-mail: info@mn-net.com
14. CromatografĂa
GENERAL CATALOGUE 2010/11
CromatografĂa de capa fina/Placas de microvaloraciĂłn
Sorbente Florisilfi para la cromatografĂa en columna Oxido de magnesio-gel de sĂlice en grano duro : MACHEREY-NAGEL MgO 15,5 Âą0,5%, SiO2 84,0 Âą0,5%, Na2SO4 â&#x2030;¤1,0% aplicaciones tĂpicas: Limpieza de residuos de pesticidas, separaciĂłn de pesticidas clorados, aislamiento de esteroides, hormonas sexuales, antibiĂłticos, lĂpidos,etc DescripciĂłn Florisil standard 60 / 100 mesh FLORISIL-Standard 60/100 mesh
TamaĂąo de partĂcula mesh/mm 0.15 / 0.25 mm 0,15 / 0,25 mm
Peso kg 1 5
ud.E
CĂłdigo
1 1
6.232 873 4.005 002
01 UHDG\ WR XVH OD\HUV IRU 7/& $GYDQWDJHV FRQWLQXRXV KLJK TXDOLW\ guaranteed by stringent production control including VWDQGDUGLVHG ORW WHVWV VXUIDFH FKHFNV IRU URXJKQHVV RU FUDFNV DV ZHOO DV KDUGQHVV DQG DGKHUHQFH FKHFNV FRPSUHKHQVLYH UDQJH RI SKDVHV IRU 7/& +37/& WKHUH LV QR XQLYHUVDO 7/& SODWH ZKLFK PHHWV DOO SRV VLEOH W\SHV RI DQDO\VHV 2XU YHUVDWLOH UDQJH RI 7/& UHDG\ WR XVH OD\HUV FRYHUV PDQ\ GLIIHUHQW W\SHV RI DSSOLFDWLRQV LPPHGLDWHO\ UHDG\ IRU FKURPDWRJUDSKLF VHSDUD tion coatings or impregnations are not necessary KRPRJHQHRXV VPRRWK ZHOO DGKHULQJ OD\HUV DQ LPSRUWDQW FULWHULXP HVSHFLDOO\ IRU UHSURGXFLEOH TXDQWLWDWLYH HYDOXDWLRQ
1274
(OHFWURQ PLFURVFRSLF SKRWRJUDSK RI D FURVV VHFWLRQ WKURXJK D JODVV SODWH ZLWK VLOLFD OD\HU PDJQLÂż FDWLRQ [
Salvo error u omisiĂłn
14. Cromatografía
GENERAL CATALOGUE 2010/11
Cromatografía de capa fina/Placas de microvaloración
Standard silica layers for TLC MACHEREY-NAGEL
Support materials for TLC ready-to-use layers
Glass plates: glass, ~ 1.3 mm thick, high requirments for weight, packaging and storage, ideal torsional strength, high temerature stability, susceptible to breakage, can not be cut with scissors, high resistance against solvents, mineral acids and conc. ammonia, suitability for aqueous detection reagents depends on the phase POLYGRAM®: polyester, ~ 0.2 mm thick, low requirments for weight, packaging and storage, low torsional strength, max. 185°C temerature stability, not susceptible to breakage, can be cut with scissors, high resistance against solvents, mineral acids and conc. ammonia, very suitable for aqueous detection reagents ALUGRAM®: aLuminium, ~ 0.15 mm thick, low requirments for weight, packaging and storage, relatively high torsional strength, high temerature stability, not susceptible to breakage, can be cut with scissors, high resistance against solvents, low resistance against mineral acids and conc. ammonia, limited suitable for aqueous detection reagents
Adamant unmodified standard silica layers for TLC silica 60, specific surface (BET) ~ 500m²/g, mean pore size 60Å, MACHEREY-NAGEL specific pore volume 0.75ml/g, particle size 5 to 17µm outstanding hardness and abrasion resistance due to an optimized binder system increased separation efficiency due to an optimized particle size distirbution high suitability for trace analyses resulting from a UV indicator with brilliance and a low-noise background of the layer available as glass plates with or without fluorescent indicator (UV254) Type
ADAMAT ADAMAT ADAMAT ADAMAT ADAMAT ADAMAT ADAMAT ADAMAT ADAMAT ADAMAT ADAMAT
Plate size
UV254 UV254 UV254 UV254 UV254 UV254 UV254
cm 2.5 x 7.5 5 x 10 5 x 10 5 x 10 5 x 10 5 x 20 10 x 10 10 x 10 10 x 20 20 x 20 20 x 20
Thickness of layer
PK
mm 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25
100 50 50 200 200 100 25 25 50 25 25
Cat. No.
4.005 4.005 4.005 4.005 4.005 4.005 4.005 4.005 4.005 4.005 4.005
060 067 061 068 062 063 069 064 065 070 066
Separation of steroids Layers: ADAMANT UV254, SIL G/UV254; eluent: trichloromethane – methanol (97:3) Developing time: 10 minutes; 0.1 % solution in CHCl3
Rf Cortisone Corticosterone Testosterone Desoxycorticosterone Progesterone Migration distance
ADAMANT 0.37 0.43 0.50 0.55 0.73 5.0 cm
SIL G 0.27 0.30 0.39 0.46 0.62 5.7 cm
MN Appl. No. 402930
Salvo error u omisión
ADAMANT UV 254
SIL G/UV254
1275
14. Cromatografía
GENERAL CATALOGUE 2010/11
Cromatografía de capa fina/Placas de microvaloración 1
2
3
1 2 3 SIL G capas de gel de sílice estándar no modificadas para la CCF (crom. capa fina) Placas de vidrio, POLYGRAMfi , ALUGRAMfi
MACHEREY-NAGEL
Gel de sílice 60, superficie específica (BET)- 500 m2/g, tamaño de poro medio 60 A, volumen de poro específico 0,75 ml/g, tamaño de partícula 5-17 µm; calidad estándar Grosor de capa para placas analíticas 0,25 mm para placas preparativas 0,5 y 1 mm, para capas preparativas con 2 mm de grosor se emplea un material algo más basto Indicadores: silicato de zinc activado por manganeso con fluorescencia verde en luz UV de onda corta (254 nm), aglutinante: producto altamente polimerizado, que es resistente en caso todos los disolventes orgánicos y frente a reactivos de detección agresivos; el sistema aglutinante de las áminas POLYGRAMfi es un eluyente acuoso puro estable.
Tipo
Formato de las placas
Glass plates SIL G-25 UV254 Glass plates SIL G-25 Glass plates SIL G-25 Glass plates SIL G-25 Glass plates SIL G-25 Glass plates SIL G-25 Glass plates SIL G-25 UV254 Glass plates SIL G-25 UV254 Glass plates SIL G-25 Glass plates SIL G-25 UV254 Glass plates SIL G-25 Glass plates SIL G-25 UV254 Glass plates SIL G-100 Glass plates SIL G-100 UV254 Glass plates SIL G-200 Glass plates SIL G-200 UV254 POLYGRAMfi polyester sheets SIL G POLYGRAMfi polyester sheets SIL G UV254 POLYGRAMfi polyester sheets SIL G POLYGRAMfi polyester sheets SIL G UV254 POLYGRAMfi polyester sheets SIL G POLYGRAMfi polyester sheets SIL G UV254 POLYGRAMfi polyester sheets SIL G POLYGRAMfi polyester sheets SIL G UV254 POLYGRAMfi polyester sheets SIL G POLYGRAMfi polyester sheets SIL G UV254 ALUGRAMfi aluminium sheets SIL G UV254 ALUGRAMfi aluminium sheets SIL G UV254 ALUGRAMfi aluminium sheets SIL G ALUGRAMfi aluminium sheets SIL G UV254 ALUGRAMfi aluminium sheets SIL G ALUGRAMfi aluminium sheets SIL G UV254 ALUGRAMfi aluminium sheets SIL G ALUGRAMfi aluminium sheets SIL G UV254 ALUGRAMfi aluminium sheets SIL G ALUGRAMfi aluminium sheets SIL G UV254 ALUGRAMfi aluminium sheets SIL G ALUGRAMfi aluminium sheets SIL G UV254
cm 2.5 x 7.5 5 x 10 5 x 10 5 x 10 5 x 10 5 x 20 5 x 20 10 x 10 10 x 20 10 x 20 20 x 20 20 x 20 20 x 20 20 x 20 20 x 20 20 x 20 2.5 x 7.5 2.5 x 7.5 4x8 4x8 5 x 20 5 x 20 20 x 20 20 x 20 40 x 20 40 x 20 2.5 x 7.5 4x8 5 x 7.5 5 x 7.5 5 x 10 5 x 10 5 x 20 5 x 20 10 x 20 10 x 20 20 x 20 20 x 20
1276
Espesor de la capa mm 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 1,00 1,00 2,00 2,00 0,20 0,20 0,20 0,20 0,20 0,20 0,20 0,20 0,20 0,20 0,20 0,20 0,20 0,20 0,20 0,20 0,20 0,20 0,20 0,20 0,20 0,20
Salvo error u omisión
ud.E
100 50 50 200 200 100 100 25 50 50 25 25 15 15 12 12 200 200 50 50 50 50 25 25 25 25 200 50 20 20 50 50 50 50 20 20 25 25
Código
4.004 6.230 4.004 4.004 4.004 4.004 6.232 9.003 6.227 6.230 9.003 9.003 4.004 7.300 6.224 4.004 4.004 4.004 4.004 9.003 6.803 9.003 6.202 9.003 4.004 4.004 4.005 9.003 4.005 6.227 6.802 9.003 7.084 9.003 4.005 6.233 7.059 9.003
850 729 848 847 849 846 660 474 917 274 491 492 853 555 417 854 827 826 825 493 651 476 190 494 822 824 043 496 042 948 883 477 918 478 052 568 745 497
14. CromatografĂa
GENERAL CATALOGUE 2010/11
CromatografĂa de capa fina/Placas de microvaloraciĂłn SILGUR capas de gel de sĂlice estĂĄndar no modificadas con zona de concentraciĂłn para la CCF Placas de vidrio
MACHEREY-NAGEL
Gel de sĂlice 60, superficie especĂfica (BET) - 500 m2/g, tamaĂąo de poro medio 60 A, volumen de poro especĂfico 0,75 ml/g, tamaĂąo de partĂcula 5-17 Âľm se suministra como placas de vidrio con y sin indicador de fluorescencia (UV 254) Zona de Kieselgur para una aplicaciĂłn rĂĄpida de la muestra: puesto que el Kieselgur es totalmente inerte frente a la mayorĂa de compuestos, las muestras son empujadas juntas siguiendo una lĂnea siempre en la lĂnea de separaciĂłn de ambos sorbentes, independientemente de como se haya aplicado la muestra en la zona de concentraciĂłn.La separaciĂłn se realiza luego en la capa de gel de sĂlice Tipo
Placa Placa Placa Placa
Formato de las placas
de de de de
vidrio vidrio vidrio vidrio
Espesor de la capa mm 0,25 0,25 0,25 0,25
cm 10x20 10X20 20X20 20X20
SILGUR 25 SILGUR-25 UV 254 SILGUR-25 SILGUR 25 UV254
ud.E
50 50 25 25
CĂłdigo
4.004 4.004 6.093 7.400
856 857 869 306
Nano-ADAMANT nanocapas de gel de sĂlice no modificadas para la HPTLC Placas de vidrio
MACHEREY-NAGEL
Gel de sĂlice 60, superficie especĂfica (BET)-500 m2/g, tamaĂąo medio del poro 60 A, volumen especĂfico del poro 0,75 ml/g, tamaĂąo de partĂcula 2-10 Âľm dureza sorprendente y resistencia a la abrasiĂłn gracias a un sistema aglutinante optimizado potencia de separaciĂłn elevada gracias a una distribuciĂłn Ăłptima del tamaĂąo de grano muy adecuada para la analĂtica de trazas gracias a un indicador UV con fuerza luminosa brillante en combinaciĂłn con una base pobre en ruido fraccionamiento estrecho de las partĂculas de gel de sĂlice que permite una precisiĂłn de separaciĂłn elevada, tiempos de separaciĂłn cortos, recorridos cortos, una cantidad de muestra mĂnima y una sensibilidad elevada en la detecciĂłn en comparaciĂłn con el gel de sĂlice estĂĄndar. se suministra como placas de vidrio con y sin indicador de fluorescencia (UV 254)
Tipo
Formato de las placas
Nano-ADAMANT NANO-ADAMANT UV 254 Nano-ADAMANT Nano-ADAMANT UV254 Nano-ADAMANT Nano-ADAMANT UV254
cm 5X5 5X5 10X10 10X10 10X20 10X20
Espesor de la capa mm 0,20 0,20 0,20 0,20 0,20 0,20
ud.E
100 100 25 25 50 50
CĂłdigo
4.005 4.005 4.005 6.226 4.005 4.005
073 071 074 346 075 072
&RPSDULVRQ RI $'$0$17 DQG 1DQR $'$0$17 SODWHV IRU VHSDUDWLRQ RI DQWKUDTXLQRQH G\HV A 1 /D\HUV $ $'$0$17 % 1DQR $'$0$17 6DPSOH Â&#x2014;O DERXW (OXHQW WROXHQH Âą F\FORKH[DQH 2 Y Y
5 0LJUDWLRQ WLPH 3 4 7 $ PLQ % PLQ 6 Peaks: 1. Blue 3 10 20 30 40 50 mm 2. Violet 2 3. Red 4. Green 5. Blue 1 1 B 6. Greenish blue 7. Violet 1 2
3
10
4
5
7
6
20
30
40 mm
Salvo error u omisiĂłn
1277
14. Cromatografía
GENERAL CATALOGUE 2010/11
Cromatografía de capa fina/Placas de microvaloración
1 Nano-SIL nanocapas de gel de sílice no modificadas para la HPTLC Alugramfi
1 MACHEREY-NAGEL
Gel de sílice 60, superficie específica (BET)-500 m2/g, tamaño de poro medio 60 A, volumen de poro específico 0,75 ml/g Tamaño de partícula 2-10 µm Indicador: silicato de zinc activado por mangano con fluorescencia verde en luz UV de onda corta (254 nm) Aglutinante:producto altamente polimérico, que es resistente en casi todos los disolventes orgánicos y contra reactivos de detección agresivos El fraccionamiento estrecho de las partículas de gel de sílice permite una precisión de separación superior, tiempos de separación más cortos, recorridos más cortos, una cantidad de muestra menor y una elevada sensibilidad en la detección en comparación con el gel de sílice estándar. Tipo
ALUGRAM ALUGRAM ALUGRAM ALUGRAM
Formato de las placas
NANP-SIL G NANO-SIL G UV254 NANO-SIL G NANO-SIL G UV254
cm 5X20 5X20 20X20 20X20
Espesor de la capa mm 0,20 0,20 0,20 0,20
ud.E
50 50 25 25
2 3 RP-18 W/UV254 nanocapas de gel de sílice modificadas por octadecilo para la HPTLC Placas de cristal, ALUGRAMfi
Código
4.005 6.227 6.227 4.005
044 900 899 045
2
MACHEREY-NAGEL
Material de base: Gel de sílice 60, superficie específica (BET) - 500 m2/g, tamaño medio del poro 60 A, volumen de poro específico 0,75 ml/g, tamaño medio de partícula 9 µm, estabilidad del pH 2-10 sustancia luminosa. Producto estable en medio ácido con fluorescencia azul en luz UV de onda corta (254 nm); aparecen sustancias que absorben los rayos UV como manchas azul oscuro hasta negras sobre el fondo azul claro modificación parcial del octadecilo, reticulable con agua, contenido de C 14% Secuencia de polaridad: gel de sílice>DIOL>NH2>CN>RP-2>C 18-50>RP-18W>C 18-100 Separaciones de fases normales y fase invertida con eluyentes de los disolventes anhidros hasta mezclas con elevado contenido en agua; la polaridad relativa del eluyente determina la polaridad de la capa.
3
aplicaciones recomendadas: aminofenoles, barbituratos, sustancias conservantes, nucleobases, hidrocarburos de carbono aromáticos policíclicos, esteroides, tetraciclina, plastificantes (ftalato) Suministrable como placas con y sin indicador de fluorescencia (UV 254nm)
Tipo
Formato de las placas
Placas de vidrio RP-18 UV 254 Placas de vidrio RP-18 W UV 254 Placas de vidrio RP-18 W UV254 Placas de vidrio RP-18W UV254 Placas de vidrio RP W UV254 ALUGRAMA RP-18 W UV254 ALUGRAMA RP-18 UV254 ALUGRAMA RP-18W UV254 ALUGRAMA RP-18 UV254 ALUGRAMA RP-18W UV 254
cm 5x20 10x10 10x20 20x20 20x20 4X8 5X10 5X20 10X10 20X20
1278
Espesor de la capa mm 0,25 0,25 0,25 0,25 1,00 0,15 0,15 0,15 0,15 0,15
Salvo error u omisión
ud.E
50 25 50 25 15 50 50 50 25 25
Código
4.004 6.206 4.004 4.004 4.004 7.400 6.901 4.005 4.005 6.704
880 173 879 878 881 375 143 046 047 046
14. Cromatografía
GENERAL CATALOGUE 2010/11
Cromatografía de capa fina/Placas de microvaloración 1
1 Placas TLC Estándar, placas rígidas TLP en una variedad de medios, materiales de apoyo y según dimensiones indicadas.
Material
Medidas
MACHEREY-NAGEL
ud.E
Código
25 25
9.003 495 9.003 498
mm poliéster con óxido de aluminio* aluminio con óxido de aluminio*
mm 0,2 200 x 200 0,2 200 x 200
*con ind. UV 254 nm
Juegos micro TLC, juegos de introducción para la clase de ciencias naturales Juego de principiantes Separación con medios simples; las muestras poseen un color propio, de manera que aparece un color Todas las propiedades del aparato se indican en el juego.
Descripción Juego TLC-micro A para principiantes
MACHEREY-NAGEL
ud.E
Código
1
6.057 472
TLC micro-set A for beginners This kit contains all chemicals and accessories for the following separations:
ϑ separation of the fat-soluble (lipophilic) test mixture 1: butter yellow, indophenol, sudan blue II, sudan red G
ϑ separation of a mixture of anthraquinone dyes (test dye mixture 2): blue 1, blue 3, green, greenish blue, red, violet 1, violet 3
ϑ separation of a mixture of food dyes (test dye mixture 3): brilliant black BN (E151), fast red E, erythrosine (E127), yellow orange S (sunset yellow CFC, E110), naphthol red S, ponceau 4 R (E124), tartrazine (E102)
ϑ separation of dyes from felt tip pens
Contents of TLC micro-set A for beginners 1 manual 3 developing chambers 50 glass capillaries 1 µl 1 spotting guide 1 measuring cylinder10 ml 50 polyester sheets each 4 x 8 cm POLYGRAM® SIL G/UV254, ALOX N/UV254 and CEL 300 8 ml each of test dye mixture 1 (4 lipophilic dyes), test dyes sudan red G and sudan blue II 8 ml each of test dye mixture 2 (7 anthraquinone dyes), test dyes blue 1 and violet 2 8 ml each of test dye mixture 3 (7 food dyes), test dyes yellow orange S and brilliant black BN 100 ml each of toluene, toluene/cyclohexane (2:1, v/v) chloroform/acetone (1:1, v/v) 2.5 % sodium citrate solution 25 % ammonia/2-propanol (5:3, v/v) 2 felt tip pens
Salvo error u omisión
1279
14. Cromatografía
GENERAL CATALOGUE 2010/11
Cromatografía de capa fina/Placas de microvaloración 1 Placas TLC
1
K Linear: da reconocimiento rápido, exacto. La capa del pre-adsorbente es más gruesa Whatman que la capa de silica y funciona como una esponja que preconcentra la muestra antes de que reaccione con la capa de la silica. Esto permite que el usuario aplique volúmenes de muestra que no serían posibles con placas TLC estándares. El símbolo del silica gel es K (del kieselgel alemán). seguido por una designación de clasificación: - K5 10 - 12µm silica con poro 150 Å - K6 10 - 12µm silica con poro 60 Å - la silica de alto rendimiento se prefija con las letras HP: HP-K 4.5, poro 60 Å - las placas de fases inversas con un grupo alkyl son representadas por una K, seguida por la longitud de la cadena alkyl KC-18 10 - 12µm Silica 60 Å, de la fase enlazada octadecil. La información adicional para la identificacón de una placa en particular se puede encontrar en los códigos siguientes: - L: capa del pre-adsorbente para el uso más fácil de volúmenes grandes. Comprime cada muestra en una banda horizontal estrecha, también conocida como Linear-K, el prefijo L. - D: placas acanaladas con carriles separados. 2 mm de canales de cristal separan los carriles individuales de la muestra para evitar que se mezclan, también para la división D. - F: indicador fluorescente, las placas fluorescentes brillan en verde intenso bajo la luz UV . Las muestras que absorben UV a 254 nm son reconocidas apagando la fluorescencia. - M: Portaobjetos, tamaño de la placa 25/75 mm. - P: capa preparatoria. Tiene un grueso de 500 o 1000 µm para muestras grandes. Estos códigos de letras permiten la identifcation fácil y rápida de todas las placas TLC, por ejemplo PLK6DF = placa de preparación K6 silica 60 Å diámetro de poro, carriles separados, indicador fluorescente y capa preadsorbente.
2 Placas flexibles TLC para cromatografía de capa fina
2
Placas de silicagel. Capa 250 µm. Todas las placas son de 20 x 20 cm y se pueden cortar con tijeras. Las placas flexibles Silica-Gel 60A, disponibles en aluminio o poliester, tienen un rendimiento similar a las placas de cristal K6 y a menudo se usan para analitos polares de moderado a fuertes. Las placas intercambiadoras de iones (DEAE) se usan para especies aniónicas y estan disponibles en soporte de poliester. Tipo PE PE AL AL
Sil Sil Sil Sil
Descripción G G/UV 254* G G/UV 254*
Con Con Con Con
reverso reverso reverso reverso
de de de de
Whatman
ud.E poliéster poliéster aluminio aluminio
25 25 25 25
Código 9.950 9.950 9.950 9.950
336 337 338 339
* Con un indicador fluorescente
3 Placas de vidrio para cromatografía de capa fina
3
Placas para cromatografía de fase reversa. Capa de 200 µm. Tipo
Tamaño
MKC18F KC18 KC18F KC18F LKC18F LKC18F LKC18F
2,5 x 7,6 cm 20 x 20 cm 5 x 20 cm 20 x 20 cm 20 x 20 cm 5 x 20 cm 20 x 20 cm
Whatman ud.E 100 25 75 25 25 75 25
Código 9.950 9.950 9.950 9.950 9.950 9.950 9.950
340 341 342 343 344 345 346
4
4 Placas de adsorción K6 60 Å. Capa de 250 µm. PK6F: Capa de 1000 µm. Tipo
Tamaño
MK6F K6 K6 K6 K6F K6F K6F K6F PK6F LK6D LK6D LK6DF LK6DF
2,5 x 7,6 cm 5 x 20 cm 10 x 20 cm 20 x 20 cm 5 x 10 cm 5 x 20 cm 10 x 20 cm 20 x 20 cm 20 x 20 cm 5 x 20 cm 20 x 20 cm 5 x 20 cm 20 x 20 cm
1280
Whatman ud.E 500 75 50 25 150 75 50 25 20 75 25 75 25
Salvo error u omisión
Código 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950
347 348 349 350 351 352 353 354 355 356 357 358 359
14. Cromatografía
GENERAL CATALOGUE 2010/11
Cromatografía de capa fina/Placas de microvaloración 1 Placas TLC
1
Silica gel 60 F 254.
Merck
Material
Anchura
Longitud
ud.E
mm 20,0 10,0 5,0 5,0 5,0 5,0 2,5 2,5 20,0 5,0 5,0 20,0
mm 20,0 20,0 20,0 20,0 10,0 10,0 7,5 7,5 20,0 10,0 7,5 20,0
25 50 100 25 200 25 100 500 25 50 20 25
Código
mm Vidrio Vidrio Vidrio Vidrio Vidrio Vidrio Vidrio Vidrio Aluminio Aluminio Aluminio Plástico
0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,20 0,20 0,20 0,20
9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130
050 051 052 053 054 055 056 057 058 059 060 063
Placas TLC Silica gel 60F 254.
Merck
Material
Medidas
ud.E
Código
20 12
9.130 061 9.130 062
mm mm Base de vidrio Base de vidrio
2
2 Papel cromatográfico/intercambiador de iones Los papeles de cromatografía de Whatman son los papeles más usados en el mundo de Whatman la cromatografía. Esta aceptación y uso refleja la pureza, alta calidad y consistencia de los papeles Whatman. Estas calidades son confiadas por cromatógrafos y esenciales para el éxito de la cromatografía. La base de papel de cromatografía Whatman es la selecta celulosa de algodón. Un riguroso control de calidad para las importantes características del cromatógrafo aseguran uniformidad dentro del grado. 1 Chr papel estándar de cromatografía en el mundo. Una superficie lisa, 0,18mm de grueso con un caudal linear (agua) de 130 mm/30 minuto. Buena resolución para las separaciones analíticas generales. 3MM Chr usado extensamente como papel secante, 3MM Chr se utiliza en electrophoresis y para la química en general. Un papel semigrueso (0,34 mm) usado ampliamente en cromatografía y electroforesis generales. El caudal es 130 mm/30 minuto. 3 Chr papel medio grueso (0,36mm) con un caudal de 130 mm/30 minuto. Para usos generales con cargas de soluciones medias/pesadas. Utilizado con frecuencia para la separación de compuestos inorgánicos y para electroforesis. 17 Chr grueso (0,92 mm) y altamente absorbente con un caudal muy alto de 190 mm/30 minuto. Apropiado para las cargas más pesadas e ideal para la cromatografía de papel y electroforesis preparatorias. Papeles de intercambio de iones DE81 Un fino y débil (0,20 mm) papel de celulosa DEAE de anión básico cambiador con los grupos funcionales dietilaminoetilo. La capacidad de intercambio de iones 1.7 µeq/cm² y el caudal es 95 mm/30 minuto. Para el uso con transcriptasas y la polimerasas del DNA invertidas. SG81 Un papel único (0,27 mmde grueso) que combina la celulosa y el poro de gel de silicona. Apropiado para separaciones en las cuales la partición y la adsorción son importantes, incluyendo la separación de fosfolípidos, esteroides, fenoles y tintes. El caudal es 110 mm/30 minuto. P81 Un papel fino de fosfato de celulosa (0,23mm). Cambiador de catión fuerte de alta capacidad. La capacidad de intercambio de iones 18,0 µeq/cm2 y el caudal es 125 mm/30 minuto. Para el uso con análisis de quinasas de proteína con substratos de péptidos. Calidad
Tamaño
1Chr 1Chr 1Chr 1Chr 3MMChr 3MMChr 3Chr 3MMChr 3MMChr 4Chr 17Chr DE81 SG81 P81
100 200 250 460 200 315 460 460 580 460 460 460 460 460
x x x x x x x x x x x x x x
300 200 250 570 200 355 570 570 680 570 570 570 570 570
ud.E mm mm mm mm mm mm mm mm mm mm mm mm mm mm
100 100 100 100 100 100 100 100 100 100 25 25 25 25 Salvo error u omisión
Código 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950
308 309 310 311 312 313 314 371 315 316 317 318 319 320
1281
14. Cromatografía
GENERAL CATALOGUE 2010/11
Cromatografía de capa fina/Placas de microvaloración-Cámaras
1
1 Papeles para cromatografía Papel cromatográfico 1CHR Papel cromatográfico estandar. Buena resolución para separaciones analíticas generales. Celulosa pura. Grueso 0,18mm. Capilares (agua) 130 mm/30 min.
Whatman
Papel cromatográfico 3MM CHR Para electroforesis, en química general y como papel secante. Pura celulosa. Grueso 0,34mm. Capilares (agua) 130 mm/30 min. Calidad 1Chr 1Chr 1Chr 1Chr 1Chr 1Chr 1Chr 3MMChr 3MMChr 3MMChr 3MMChr 3MMChr 3MMChr
Anchura mm 10 20 30 40 50 100 150 20 100 150 190 230 270
Longitud mm 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
ud.E 1 1 1 1 1 1 1 1 1 1 1 1 1
Código 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950
322 323 324 325 326 328 329 327 330 331 332 333 334
Papeles para cromatografía Dividido en 12 bandas, 15 mm de ancho cada una, para separaciones de 12 muestras en paralelo. Calidad 1Chr CRL
2
Anchura mm 110
Longitud mm 213
Whatman ud.E
Código
100
9.950 321
2 Cubetas estándar de revelado Con los cantos de la base y tapa esmerilados, para todo tipo de placas cromatográficas de hasta 200 x 200 mm. Base absolutamente plana. Otros tipos de cubetas bajo pedido. Tipo
ud.E
Cubeta de revelado con asa tipo bola Cubeta de revelado con placa de vidrio esmerilado Asa tipo bola para ref. 9.020 160 Placa de vidrio para ref. 9.020 173
3
9.020 9.020 9.020 9.020
160 173 163 177
3 Cubeta de revelado simultáneo para TLC Para placas cromatográficas de hasta 20 x 20 cm.
1282
1 1 1 1
Código
Salvo error u omisión
MACHEREY-NAGEL
14. Cromatografía
GENERAL CATALOGUE 2010/11
Cromatografía de capa fina/Cámaras-Jeringas 1 Cubetas de revelado simultáneo
1
Cantos de la base y tapa esmerilados, con ranuras para introducir 5 placas cromatográficas de TLC de 200 x 200 mm. Base absolutamente plana.
Tipo Cubeta de revelado simultáneo con placa de asa tipo bola Cubeta de revelado simultáneo con placa de vidrio
2 Cubetas de revelado para nanocromatografía
ud.E
Código
1
9.020 167
1
9.020 174
ud.E
Código
1
9.020 112
1
9.020 210
1
9.020 212
2
La nanocromatografía de capa fina TLC o HPTLC encuentra cada vez más aplicación. Por ello, se han desarrollado cubetas de revelado para los formatos de placa más usados, es decir de 100 x 100 mm y 200 x 100 mm, manteniendo las ventajas de las cubetas.
Tipo Cubeta de revelado para placas de nanocromatografía de 200 x 100 mm, con tapa de acero inoxidable Cubeta de revelado para placas de nanocromatografía de 100 x 100 mm, con tapa de casa tipo bola Cubeta de revelado para placas de nanocromatografía de 100 x 100 mm, con tapa de acero inoxidable Tapa de acero inoxidable de 200 x 100 mm Tapa de 100 x 100 mm con asa tipo bola Tapa de acero inoxidable de 100 x 100 mm Nanofiltro de papel para saturación con gas de la cubeta 210 x 110 mm, 25 hojas
1 1 1 25
3 Cubetas de revelado H
9.020 9.020 9.020 9.020
117 211 213 214
3
Esta cubeta aprovecha plenamente las ventajas de la cromatografía HPTLC. Tamaño de Sarstedt (Desaga) partícula pequeño (5 µm), mejor empaque y más platos teóricos. Es económica y se suministra tanto para el formato 50 x 50 mm (económico y rápido) como para el formato clásico 100 x 100 mm. Se consiguen separaciones óptimas incluso en los recorridos más cortos. Tipo Cubeta de revelado H Cubeta de revelado H Varillas sinterizadas Tapa Tapa
Anchura mm 50 100 0 50 100
Longitud mm 50 100 50 50 100
ud.E 1 1 5 1 1
Código 9.023 9.023 9.023 9.023 9.023
150 160 955 956 957
4 5 Jeringas desechables de PP
4
Jeringuilla en 2-piezas: Cilindro: PP. Pistón: PE. Estériles. Desechable con punta Luer.
Capacidad ml 1 : 1/100 (Tuberculina) 2 (3) 5 (6) 10 (12) 20 (24) 30 50 (60)
ud.E 100 100 100 100 100 50 30
Salvo error u omisión
Código 9.410 9.410 9.410 9.410 9.410 9.410 9.410
5
000 002 005 010 020 025 050
1283
14. Cromatografía
GENERAL CATALOGUE 2010/11
Cromatografía de capa fina/Jeringas 1
1 Jeringas desechables De polipropileno con émbolo de dos piezas y conexión Luer. Sin aguja. Estériles. Se suministran en sobres individuales colocados en cajas. Capacidad ml 1 2 5 10 20 50
2
ud.E 100 100 100 100 120 60
4
Capacidad Graduación ml ml 25 1 50 1 100 1 50 1 100 1
Tipo
6
7
1284
296 297 298 299 300 301
Poulten & Graf
ud.E
sin llave de paso sin llave de paso sin llave de paso con llave capilar con llave capilar
1 1 1 1 1
Código
9.143 9.143 9.143 9.143 9.143
055 056 057 066 067
4 5 Jeringas de vidrio FORTUNA OPTIMAfi Vidrio borosilicato. Con cono de vidrio o metálico centrado. Émbolo y cilindro intercambiables. Graduación de color ámbar. Esterilizables hasta 134°C.
5
9.950 9.950 9.950 9.950 9.950 9.950
2 3 Jeringas de muestreo FORTUNAfi De vidrio de borosilicato. Cilindro transparente calibrado. Graduación ámbar grabada (difundida) resistente frente a ácidos y bases.
3
Código
Capacidad Material Cono del ml 1 Vidrio 2 Vidrio 5 Vidrio 10 Vidrio Vidrio 20 50 Vidrio 1 Metálico 2 Metálico 5 Metálico 10 Metálico 20 Metálico 50 Metálico
Poulten & Graf
Conexión
ud.E
Luer Luer Luer Luer Luer Luer Luer-Lock Luer-Lock Luer-Lock Luer-Lock Luer-Lock Luer-Lock
1 1 1 1 1 1 1 1 1 1 1 1
Código
9.222 9.222 9.222 9.222 9.222 9.222 9.222 9.222 9.222 9.222 9.222 9.222
021 022 025 030 032 035 061 062 065 070 072 075
6 7 Glass-metal syringes With calibrated glass cylinder and plunger made of stainless steel. Plungers and cylinders interchangeable. With central metal cone. Graduated. Sterilizable ip to +200°C.
Henke-Sass, Wolf
Capacidad ml 1 2 5 10 20 50 1 2 5 10 20 50
Conexión
ud.E
Luer Luer Luer Luer Luer Luer Luer-Lock Luer-Lock Luer-Lock Luer-Lock Luer-Lock Luer-Lock
1 1 1 1 1 1 1 1 1 1 1 1
Salvo error u omisión
Código 9.222 9.222 9.222 9.222 9.222 9.222 9.222 9.222 9.222 9.222 9.222 9.222
221 222 225 230 232 235 241 242 245 250 252 255
14. Cromatografía
GENERAL CATALOGUE 2010/11
Cromatografía de capa fina/Jeringas-Detección 1 Agujas desechables
1
Estériles. Envase individual. Con Cono Luer. Conexión de plástico. Tipo Pravaz Pravaz Pravaz Pravaz Pravaz Pravaz Pravaz
1 2 12 14 16 18 20
Ø mm 0,9 0,8 0,7 0,6 0,6 0,5 0,4
Longitud mm 40 40 30 30 25 25 20
Color
ud.E
amarillo verde negro azul azul marrón gris
100 100 100 100 100 100 100
Código 9.410 9.410 9.410 9.410 9.410 9.410 9.410
101 102 112 114 116 118 120
2 Agujas desechables
2
Acero inoxidable Con conexión Luer para utilizar con jeringas desechables. Estériles. Se suministran en cajas de 100 envases individuales sellados. Con códigos de colores. Calibre 18G 19G 20G 21G 23G 25G
x x x x x x
1 1½ pulgada 1 1½ pulgada 1 pulgada 1 1½ pulgada 1 pulgada 5 /8 pulgada
Ø mm 1,2 1,1 0,9 0,8 0,6 0,5
Longitud mm 40 40 25 40 25 16
ud.E 100 100 100 100 100 100
Código 9.950 9.950 9.950 9.950 9.950 9.950
302 303 304 305 306 307
9.950 302 es una aguja de pared delgada con una pequeña inclinación. 9.950 304 y 9.950 305 son agujas intravenosas de pared delgada.
3 Microcapilares
3
Estos capilares desechables se rellenan por si solos de punta a punta. Tienen una precisión superior al 1 %. Con cada envase se suministra un soporte de capilares. Además de una guía, el soporte tiene una pequeña bolita con un orificio en el que encaja el capilar. Este dispositivo es de gran ayuda a la hora de sacar o meter los capilares en el soporte. Capacidad µl 0,5 1,0 2,0 5,0 10,0
ud.E 100 100 100 100 100
Código 9.020 9.020 9.020 9.020 9.020
192 193 194 195 196
4 Nebulizador SG 1
4
Nebulización sin CFC con bomba potente y silenciosa. No depende de la red eléctrica. Nebuliza finamente líquidos con viscosidades próximas a las de los aceites ligeros. El diámetro de partícula oscila entre 5 y 10 µm con un caudal de 20 ml/min (agua). La botella que contiene el reactivo a nebulizar es de vidrio de borosilicato. Se enrosca en el cabezal nebulizador, fabricado con PTFE de gran calidad, y se puede cambiar en segundos. El cargador rápido puede servir como soporte de almacenamiento. Gracias a la protección contra sobrecargas el nebulizador puede permanecer constantemente en el cargador. Se suministra con batería recargable, cargador, frasco y cabezal nebulizador.
Tipo SG 1 Recipiente de la sustancia 50 ml
ud.E
Código
1 10
9.539 045 9.539 046
5 Nebulizador especial
5
Con pera de goma para nebulizar reactivos. Se puede conectar a otra fuente de aire a presión. Tipo Nebulizador especial
Salvo error u omisión
ud.E
Código
1
9.024 000
1285
14. Cromatografía
GENERAL CATALOGUE 2010/11
Cromatografía de capa fina/Detección 1
1 Nebulizador para tubos de ensayo De vidrio. Para nebulizar cantidades muy pequeñas de reactivos. El dispositivo nebulizador está alojado en un tubo de ensayo de 12 ml con junta que se ajusta al tubo de ensayo mediante pinzas. Tipo Nebulizador para tubos de ensayo
2
ud.E
Código
1
9.023 990
2 Pulverizador con ventilador Para pulverizar placas DC con medios agresivos. Carcasa de PVC resistente a los ácidos, para placas hasta 200 x 200 mm. El ventilador silencioso mueve 400 m³/h. El empalme del tubo está orientado hacia arriba para la conexión de un tubo de instalación de 100 DN. Las gotas de reactivo se recogen en una cubeta a parte. Medidas (An x F x Al) 620 x 610 x 580 mm. Tipo Pulverizador con ventilador
ud.E
Código
1
9.020 031
3 Termoplaca S Placa calefactora electrónica de precisión para laboratorios, ideada para garantizar un calentamiento controlado y uniforme de placas de cromatografía de capa fina con el fin de mejorar la repetibilidad y evaluación. Con ella se calienta la zona de aplicación para una rápida evaporación del solvente. Secado intermedio definido durante revelados múltiples. Concentración o evaporación de pequeñas cantidades de líquido a temperatura constante. Conservación del calor en reacciones a una temperatura prefijada, p. ej. en determinaciones colorimétricas. Control visual de la aparición de color. La temperatura se prefija e indica digitalmente.
3
Superficie caliente: Rango de temperatura: Precisión:
240 x 240 mm 25 a 199°C 2K
Tipo Termoplaca S
ud.E
Código
1
9.023 840
4 Lámpara para análisis con luz transmitida CabUVIS. Iluminación uniforme con tubos fluorescentes de Hg de baja presión para 254 y 366 nm, y filtros UV especiales. Luz reflejada y transmitida con tubos fluorescentes de luz diurna de 8 W y pantalla difusora de 200 x 200 mm. El equipo básico se suministra con tapa transparente. Existe un accesorio opcional que permite observar o documentar objetos sin espacio oscuro. Tipo CabUVIS
4
1286
Salvo error u omisión
ud.E
Código
1
9.539 341
14. Cromatograf铆a
GENERAL CATALOGUE 2010/11
Cromatograf铆a de capa fina/Detecci贸n 1
2
1 2 HPLC Detector lamps Kinesis Type
Para
PK
Cat. No.
LD-ABI-100
ABI 757 759 783A 785A 1000S 980 120A 130A D2 Lamp
1
4.007 053
LD-AGI-101 LD-AGI-104 LD-AGI-104LL LD-AGI-105 LD-AGI-105LL LD-DIO-102LL LD-DIO-105LL
Agilent Agilent Agilent Agilent Agilent Dionex Dionex
1 1 1 1 1 1 1
4.007 4.007 4.007 4.007 4.007 4.007 4.007
LD-GIL-101
Gilson115/116/117/118/119/151/152/155/156 D2 Lamp
1
4.007 108
LD-JAS-101LL
Jasco 970 975 (B & C Series) 1570 1575 2075 D2 Lamp
1
4.007 112
LD-KNA-101 LD-MEH-100
Knauer Wellchrom K2000 K2500 K2501 D2 Lamp Hitachi LaChrom L Series, Elite, U Series nosed D2 Lamp
1 1
4.007 115 4.007 127
LD-PER-100-3 LD-PER-160
Perkin Elmer Series 200 D2 Lamp XPack3 PE Lambda 2 to 45 800 900 Bio, 55X Series LC480 D2 Lamp
1 1
4.007 132 4.007 139
LD-SHI-101LL
Shimadzu SPD-10A, AVP, AV, AVVP, M10AVP, 20A, 20AV Lamp
1
4.007 156
LD-SHI-102 LD-SHI-103LL LD-TSP-102
Shimadzu Spectrophotometer D2 Lamp Shimadzu LC2010 Longlife D2 Longlife Lamp TSP UV100/1000/2000/3000 Focus Spectrachrom D2 Lamp
1 1 1
4.007 157 4.007 159 4.007 164
LD-TSP-106 LD-VAR-103LL
TSP UV 6000 DAD Surveyor D2 Lamp Varian UV50/100/200 9050 Prostar 310 D2 Longlife lamp
1 1
4.007 167 4.007 173
LD-VAR-105LL LD-WAT-102 LD-WAT-104LL LD-WAT-105LL
Varian Prostar 325 335 Longlife D2 Lamp Waters 486 D2 Lamp Waters 996, 2996 PDA Longlife D2 Lamp Waters 2487 Longlife D2 Lamp
1 1 1 1
4.007 4.007 4.007 4.007
1050C 1050DAD 1090 D2 Lamp 1100 VWD D2 Lamp 1100 VWD Longlife D2 Lamp 1100 DAD, 8453 D2 Lamp 1100, 1200 DAD Longlife D2 Lamp PDA-100, PDA-3000, AD-25 D2 Lamp Ultimate UVD 3000 Nano LC D2 Longlife Lamp
Salvo error u omisi贸n
058 061 064 067 070 096 099
176 184 186 188
1287
14. Cromatografía
GENERAL CATALOGUE 2010/11
Cromatografía de capa fina/Detección-Accesorios 1 Lámpara para análisis HP-UVISfi
1
Para análisis con luz UV sin espacio oscuro. La lámpara de mercurio de alta presión emite una radiación muy intensa a 366 nm para la evaluación fluoroanalítica. A 254 nm se obtiene un contraste óptimo gracias a filtros especiales. Requiere menos espacio pese a contar con la misma posibilidad de observación de 2 placas de 200 x 200 mm. Evaluación cómoda gracias a la posición inclinada de las placas. Medidas (largo x ancho x alto): 325 x 280 x 475 mm. Alimentación: 230 V. Tipo HP-UVIS
ud.E
Código
1
9.539 360
2 UV irradiation systems BIO-LINK
2
-
Compact and powerful, ideal for a broad range of applications Precise measurement and control technology, non-ageing UV sensors Choice for irradiation parameter energy or time Easy operation: Programme memory, storage of the last parameters, programme resumes after opening of the door, auto-restart after power failure - Secure and stable construction, very easy to use - Available in 3 different wavelengths - Easy exchange of the UV tubes for wavelength change Dimensions (WxDxH) Housing: Interior:
350 x 360 x 305mm 260 x 330 x 145mm
Type
Description
Tubes
BLX-E254 BLX-E312 BLX-E365
UV crosslinker UV irradiation system UV irradiation system
5x8W 5x8W 5x8W
Wavelength nm 254 312 365
PK
Cat. No.
1 1 1
9.971 923 9.971 924 9.971 925
3 TLC Viewing cabinets
3
Model CN-6: - for one or two UV hand lamps model VL-6; choice of combined wavelengths 254nm, 312nm and 365nm - cabinet dimensions (WxDxH): 300 x 280 x 240mm; easy access also for large samples Model CN-15: - integral high intensity UV lamps, extra large capacity; easy access also for large samples; white-light bulb for normal observation - removable bottom panel for use with an ETX Professional Line transilluminator - cabinet dimensions (W x D x H): 505 x 415 x 280mm Type
Description
Tubes
CN-6 CN-15.LC*
without UV handlamps with integrated UV tubes and white-light source
2 x 15W each
Wavelength nm 365 / 254
PK
Cat. No.
1 1
9.971 926 9.971 927
Other models available on request
Juego de accesorios DC MACHEREY-NAGEL Descripción
ud.E
Cámara simultánea DC para 5 placas, 20x20 cm Pulverizador de laboratorio, vidrio con bola de goma Capilares de vidrio 1 µl Plantillas del pedido Papel de cromatografía MN 260, 7,5x17 cm (para saturación de cámara)
4
1 1 150 2 100
Código 9.003 4.004 7.056 4.004 4.004
500 909 849 903 907
4 Cortador de placas de cromatografía de capa fina Para cortar placas de vidrio de TLC o hacer incisiones sobre ellas. Concebido para ahorrar costes en el consumo de placas, o para preparar derivados con las distintas franjas de la placa tras la separación. Se suministra con rueda de corte y plantilla. Tipo Cortador de placas de cromatografía de capa fina
1288
Salvo error u omisión
ud.E
Código
1
9.539 041
14. Cromatografía
GENERAL CATALOGUE 2010/11
Cromatografía de capa fina/Accesorios-Accesorios generales 1 Plantilla universal para aplicación y evaluación
1
De plexiglás. Facilita la aplicación, rotulación y evaluación de cromatogramas en capa fina. Tamaño: 200 x 200 mm. Tipo Plantilla universal para aplicación y evaluación
ud.E
Código
1
9.020 131
2 Plantillas de aplicación
2
Topes para colocar la placa exactamente sobre la plantilla. Guía exacta para pipetas mediante cortes triangulares en la rejilla de 5mm, con lo que se obtienen 9, 19 o 39 puntos de aplicación, dependiendo del tamaño de la plantilla. La plantilla tiene una base antideslizante para evitar que se desplace sobre la mesa de trabajo. Anchura mm 100 50 100 200
Longitud mm 100 50 200 200
ud.E 1 1 1 1
Código 9.020 9.020 9.020 9.020
134 135 136 137
3 Secador para laboratorio 3 velocidades, 230 V, (0/700/1400 W). 2 niveles de calor o soplado, tobera adicional, botón para aire frío, filtro de aire extraíble. Cable de 3 m (muy flexible). Color: cromo/negro. Tipo
ud.E
Código
1
9.018 995
3 Secador para laboratorio
Secador del laboratorio profesional PHT 30 3 niveles de calor y 3 de aire frío y 3 velocidades que permiten 12 combinaciones calor/aire frío. Protección contra sobrecalentamiento. Rejilla de entrada de aire y filtro extraíbles. Requisito de alimentación: 230 a 240 V, 50 Hz, 1600-1800 W. Tipo PHT 30
Salvo error u omisión
ud.E
Código
1
9.106 809
1289
THE NEW DURAN GROUP The DURAN GROUP brings together expertise in specialist glass manufacturing with the technical heritage of its former parent, SCHOTT AG. At its production plants in Mainz and Wertheim, Germany and Pula, Croatia, the DURAN GROUP controls the entire process chain from raw material selection and glass melting to intricate postprocessing and machining processes. The DURAN GROUP offers its customers the flexibility of a medium-sized business combined with the extensive skills and expertise resulting from many years of experience.
WHY DURAN® IS SPECIAL Optimum physical and chemical characteristics make DURAN® glass the material of choice for laboratory applications: • Uniform wall thickness distribution throughout the product • Therefore better mechanical stability and greater thermal shock resistance • Prevents material stresses, which may cause the glass to crack when subject to heating or cooling • Benefits: improves safety for laboratory technicians, increases the lifespan of laboratory glassware and protects valuable substances.
THE BATCH CERTIFICATE All DURAN® laboratory glass bottles, beakers, Erlenmeyer flasks and reagent bottles have a “Retrace Code”. • An eight-digit batch code printed on the product • By providing the retrace code and the DURAN® product number, the end-user can quickly retrieve a batch and quality certificate at any time from the DURAN GROUP homepage • Allows bottles, beakers, and Erlenmeyer flasks to be retraced to the point of production, including the corresponding batch • Provides a continuous record within our quality management system
DURAN GROUP GmbH D-55122 Mainz info.duran@duran-group.com
www.duran-group.com
Our umbrella brand
Our product brand
The highest quality, for a performance you can measure.
VITLAB
volumetric flasks opaque for a greater protection of light-sensitive substances. ®
VITLAB
appeal 128 907
plastic products in sterile packaging for secure work processes. ®
VITLAB
liquid handling instruments for the best measurement results. ®
VITLAB
®
is one of the leading manufacturers of Liquid Handling instruments and high
quality plastic laboratory products. Our development and manufacturing goals are laboratory products that simplify your daily work and always produce perfect results. VITLAB® also offers a wide range of sterile plastic products in individual packaging to suit your needs. When using them, the time-consuming cleaning and autoclaving processes required when working with glass or plastic labware without sterile packaging are no longer necessary. Your work processes become more secure and you save time and money. VITLAB GmbH • Linus-Pauling-Str. 1 • 63762 Grossostheim • Germany • tel: +49 (0) 6026 9 77 99-0 • fax: 9 77 99-30 • e-mail: info@vitlab.de • www.vitlab.de