GC_2010_UK_Chap3

Page 1

GENERAL CATALOGUE 2010/11

3. Analytical measurement and testing Contents

Electrochemical meters

246

Multi meters 246 + pH meters 259 + Conductivity meters 279 + Oxygen meters 286

Balances

292

Pocket balances 292 + Precision balances 296 + Analytical balances 302 + Moisture balances 305 + Accessories 308

Thermometers

312

Laboratory thermomters 312 + Contact, Insertion themometers 319 + Temperature meters 328 + Temperature logger 333

Timing

338

Timers 338 + Clocks 343

Climate measurement

344

Hygrometer 344 + Special climate meters 350

Density determination

352

Density meter, Pycnometer 352 + Viscosimeter 358

Analytical instruments and systems

363

Melting point determination 363 + Spectrophotometers 368

245



GENERAL CATALOGUE 2010/11

3. Analytical measurement and testing Electrochemical meters/Multi meters

1 2 3 4 MultiLine⊃ IDS A new definition of multiparameter measurement WTW The new MultiLine⊃ handhelds with intelligent digital IDS sensors are perfectly suited for all multiparameter applications. The biggest advantage: signals are directly processed in the sensor. Each sensor logs onto the instrument and transfers its ID data including calibration records. Theres no danger of confusion, the digital signal transfer allows the use of long cables for all parameters. The unique QSC functionality for IDS pH sensors gives a realistic rating of the current sensor condition. The pH CMC indicates the optimum pH measuring range. A wide range of IDS pH, conductivity and DO probes covers almost any application. Universal waterproof quick-locks secure the sensor against loss. The robust and waterproof (IP67) MultiLine⊃ handhelds are equipped with a colour graphic display for optimum information. A special silicone keypad provides excellent handling comfort. For data transfer to USB sticks or selected printers a USB host interface is provided. NiMHrechargeable batteries provide an energy-efficient operation. Available as field case sets including sensors and accessores.

2

3

4

1

265

E & OE.

247


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Multi meters 1 2 3

There are 3 different models available: WTW Multi 3410: A single channel meter for pH, ORP, conductivity and DO measurement. It is particularly aimed at those users measuring one parameter but occasionally having requirements for measuring a second or third. Multi 3420: A dual channel instrument for simultaneous measurement of two equal or different parameters Multi 3430: A triple channel instrument for simultaneous measurement of up to three equal or different parameters Selected IDS-Sensors: SenTix® 940: Low maintenance combined pH electrode with ATC, QSC suitable, memory for 10 calibrations, stored serial number, pH 0.000 to 14.000 (±0.004 pH), temperature range 0.0 to 80.0°C ±0.2°C SenTix® 950: Combined pH-electrode with plastic shaft, 3 mol/l KCl, ATC, QSC-suitable, memory for 10 calibrations, stored serial number, pH 0.000 to 14.000 (±0.004 pH), temperature range 0.0 to 80.0°C ±0.2°C SenTix® 980: Combined pH-electrode with plastic shaft, 3 mol/l KCl, ATC, platinum wire junction, QSC-suitable, memory for 10 calibrations, stored serial number, pH 0.000 to 14.000 (±0.004 pH), temperature range 0.0 to 100.0°C ±0.2°C

1

TetraCon® 925: Robust, general purpose 4-electrode conductivity cell with graphite electrodes incorporating integral temperature sensor. Memory for 10 calibrations, stored serial number, measuring range 10 µS/cm to 2000 mS/cm ±0.5% of value, 0.0 to 100.0°C ±0.2°C LR 925/01: 2-electrode stainless steel conductivity cell for low conductivities, integrated temperature sensor, flow through vessel, memory for 10 calibrations, stored serial number, measuring range 0.01 µS/cm to 200µS/cm ±0.5% of value, 0.0 to 100.0°C ±0.2°C FDO® 925: Extremely fast (T99< 60 s) and precise optical DO sensor for field and laboratory applications. Handy, suits in different BOD bottles. Waterproof for depth measurement to 25m. Bevelled, air bubble repelling membrane, Green light technology for extended operation time. Insensitive against H2S. O2 concentration: 0.00 to 20.00mg/l, O2 saturation: 0.0 to 200.0% O2 partial pressure: 0.0 to 400hPa. Accuracy ±0.5% of value. 9.920 048

2

Measurement ranges pH: mV: Conc.: Oxygen measurement O2 concentration: O2 saturation: O2 partial pressure: Conductivity measurement:

Temp.: Memory: Power supply:

9.920 050

3

-2.000 to 20.000 -2.00 to +20.00 ±2500,±1250 0.00 to 20.00 mg/l (20.0mg/l*) 0.0 to 400% 0.0mS/cm to 2000mS/cm in 5 mode 0.00µS/cm to 19.99µS/cm (at K=0.1cm−1) 0.000µS/cm to 2.000µS/cm (at K=0.01cm−1) -5.0°C to +105°C manual or time controlled logger, 10000 records 4 x 1.2V NiMH, A-Type, battery charger

9.920 047

Type Multi Multi Multi Multi Multi

Description 3410 3410 3420 3420 3430

248

SET SET SET SET SET

5 E H G G

including including including including including

PK

FDO⊃ 925-3 m SenTix⊃ 980, LR 925/01 SenTix⊃ 950, TetraCon⊃ 925 SenTix⊃ 940-3,FDO⊃ 925-3,TetraCon⊃ 925-3 SenTix⊃ 940-3,FDO⊃ 925-3,TetraCon⊃ 925-3

1 1 1 1 1

E & OE.

Cat. No. 9.920 9.920 9.920 9.920 9.920

046 047 048 049 050


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Multi meters 1 Multiparameter Multi 350i Multi 350i with combined conductivity/ dissolved oxygen sensor ConOx

WTW

1

- measures pH/oxygen/conductivity/temperature simultaneously - data logger and memory for 1500 GLP compliant entries - universal, robust, watertight The new Multi 350i: multifunctional, with high accuracy, flexible usage, universal application. A multi for every situation: pH, ORP, ISE, oxygen, conductivity, in a pocket unit. Up to 4 parameters including temperature can be simultaneously measured, displayed and stored by using the new combined conductivity/oxygen sensor ConOx. Beyond this, in addition to pH and combined ISE, every currently-available WTW oxygen or conductivity sensor can be connected to this unit. Menu-driven, backlit graphics display, data logger and 1800 data point memory. Builtin, high-quality NiMH batteries give up to 500 hours of continuous use, universal power supply for charging and operating where power is available. Set includes electrodes and accessories. PC communication package also available.

Measurement ranges pH/ion measurement: pH: mV: Conc.: Oxygen measurement O2 concentration: O2 saturation: O2 partial pressure: Conductivity measurement:

Temp.: Salinity: TDS: Specific resistance: Temperature compensation pH/ion measurement: oxygen measurement: conductivity measurement:

-2.00 to 19.999 -999.9 to +999.9 -1999 to +1999 0.01 to 1999 mg/l 0.00 to 19.99 mg/l (19.9 mg/l*) 0.0 to 90.0 mg/l (90 mg/l*) 0.00 to 19.99 % 0.0 to 600 % 0.0 to 199.9 mbar (199 mbar*) 0.0 to 1250 mbar 0.0 mS/cm to 2000 mS/cm in 5 measuring ranges in AutoRange mode plus: 0.00 µS/cm to 20.00 µS/cm (at K=0.1 cm−1) 0.000 µS/cm to 2.000 µS/cm (at K=0.01 cm−1) -5.0°C to +105°C 0.0 to 70.0 0 to 1999 mg/l 0.00 to 1999 M W auto. -5 to +105.0°C man. -20 to +130°C at ambient temp. 5°C to 30°C: ±0.5 %, < 2 % at 0 to +40°C Temp: ±0.01 K non-linear function for ultrapure water, water EN 27 888 linear comp. of 0.01% to 3.00%/K compensation can be ad

Barometric compensation Oxygen measurement: Salinity correction Oxygen measurement: Reference temperature Conductivity measurement: Cell constant Conductivity measurement:

265

autom. with integral pressure sensor (500 to 1100 hPa) automatic selectable 20°C or 25°C fixed 0.475 cm−1, 0.1 cm−1, 0.01 cm−1, adjustable between 0.25 to 2.5 cm−1, 0.09 to 0.11 cm−1

Description

PK

Cat. No.

with pH/DIN input, a.c. adapter, operating instructions, without sensors, PC communication pack

1

9.920 035

with pH/DIN input and SenTix 41-3m, ConOx-3m, transport case incl. accessories and PC com.

1

9.920 036

Sentix 41-1m, accessories in transport case Set with multi parameter sonde MPP350 and transport case

1 1

9.920 023 9.920 024

E & OE.

249


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Multi meters 1 Conductivity and oxygen sensor ConOx

1

- Measures oxygen, conductivity and temperature simultaneously - Enables full automatic salinity correction - Modular structure, lean and handy

WTW

ConOx: with fully automatic salinity correction for conductivity and oxygen measurement. A narrow and handy sensor for three parameters: conductivity, dissolved oxygen and temperature. The oxygen module is simple to replace and operates on the proven galvanic principle. Ready to use immediately, low maintenance, for all water analysis applications in the laboratory and field - such as ground water and well water measurements. With the A325/S attachment and SK-325 cage guard, this instrument is outstanding for fish farm applications. Includes calibration vessel OxiCal⊃ CX. The conductivity sensor uses the proven 4-pole technique. It can also be operated without the oxygen module. Precise, insensitive to deposits and dirt, easy to clean: the hallmark of user-friendly, modern instrument technology. Specifications: Electrode material: Shaft material: Shaft length: Cell constant: Diameter: Measuring range: Temperature range: O2 sensor type:

Graphite Epoxy/POM about 145 mm 0.475 cm−1 15.3 mm 1 µS/cm to 2 S/cm 0 to 50°C galvanic

Type ConOx-1.5 ConOx-3 ConOx-6

PK

Cat. No.

1 1 1

9.920 039 9.920 040 9.920 041

2 ProfiLine Multi 1970i Multi 197i is robust - watertight - reliable - a true multi-talented instrument for measuring at depth

2

WTW

The new WTW ProfiLineMulti 197i is not only protected from strong water jets (IP66) but also submersion (IP67). It has a GLP-compliant memory with real-time clock (500 data records) as well as memory output capabilities via an RS232 interface. It accommodates simultaneous connection of pH, conductance and oxygen sensors. The parameter to be measured is set into the display with the "M" function key and can then be measured or stored. Includes a combination carrying handle/stand bracket as well as a carrying strap. The Multi 1970i has an integrated preamplifier which makes it suitable for depth measurements (down to 100m) in single parameter mode when combined with the WTW depth probe.

Specifications: Measurement ranges pH measurement:

pH: -2.00 to 19.99 mV: -1999 to +1999

Oxygen measurement O2 concentration: O2 saturation: Conductivity measurement:

Temperature compensation pH measurement:

265

Oxygen measurement: Conductivity measurement: Air pressure compensation oxygen measurement: Salinity correction oxygen measurement: Reference temperature conductance measurement: Cell constant conductivity measurement:

Type ProfiLine Multi 1970i

250

E & OE.

0.00 to 19.99 mg/l 0.0 to 90.0 mg/l 0.00 to 19.99 % 0.0 to 600 % 0.0 mS/cm to 500 mS/cm in 4 measurement ranges when in AutoRange mode Temp.: -5.0°C to +105.0°C Salinity: 0.0 to 70.0 automatic -5 to +105.0°C manual -20 to +130°C for ambient temp. 5°C to 30°C: ±0.5 % < 2 % at 0 to +40°C non-linear function for natural water per EN 27 888 automatic with integral pressure sensor (500 to 1100 hPa) automatic 20°C/25°C, selectable K=0.475 cm−1

PK

Cat. No.

1

9.920 034


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Multi meters 1 Multiparameter meter inoLab⊃ Multi 720

1

inoLab⊃ Multi 720 is an economical basic level unit for routine measurements. With its large multifunctional display it is possible to carry out all standard measurements which do not require GLP-compliant documentation. Specifications: pH-measurement Measuring ranges: pH: mV:

WTW

-2.00 to +16.00 ±199.9 ±1999 automatic -5 to +105.0°C manual: -20°C to +130°C

Temperature compensation: Oxygen measurement Measuring ranges: O2 concentration O2 saturation O2 partial pressure Temperature compensation: Temperature measuring range: Conductivity measurement Measuring ranges:

Salinity: TDS: Temperature compensation: Temperature measuring range:

0.00 to 19.99mg/l 0.0 to 90mg/l 0.0 to 90mg/l 0 to 600% 0.0 to 199.9 mbar 0 to 1250 mbar Automatic via IMT- compensation of 0 to 40°C 0 to +50°C 0.0 µS/cm to 500 µS/cm in 5 measuring ranges or AutoRange, additionally for K = 0.01 (0.000 to 1.999 µS/cm) K = 0.1 (0.00 to 19.99 µS/cm) 0.0 to 70.0 0 to 1999mg/l Linear and non-linear function for pure and natural water -5.0 to +105.0°C

Type

Description

inoLab⊃ Multi 720 inoLab⊃ Multi 720 set

meter only incl. Sentix 81, CellOx 325, TetraCon 325, accessories

265

PK

Cat. No.

1 1

9.704 195 9.704 207

We can supply this

manufactorer’s whole product range !

E & OE.

251


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Multi meters 1 Multiparameter meter pH/ION/Cond 750

1

Two independent galvanic pH inputs make it possible to perform simultaneous WTW measurements of pH value, Redox potential or ion concentration. Calibration procedures, with up to 7 standard solutions, can be carried out for exact measurements across the entire range of an ISE electrode. Up to 5 individual calibration routines can be stored in memory. The calculation of the calibration curve makes allowance for non-linear segments. The following processes are available for determining ion concentrations: Direct potentiometry, standard addition/subtraction, specimen addition/subtraction, double standard addition, blank value correction, standard addition with blank value correction, reference measurement. The conductivity measurement allows specific resistance, salinity, TDS and specimen-specific temperature coefficients to be determined. Concentration curves for standard chemicals, like NaCl, are already stored in the instrument. A wide range of additional functions, such as measurement data management, PC connection via MultiLab⊃ pilot, GLP compliant calibration and measurement data acquisition, and bi-directional RS 232 interface are also incorporated.

265

Measurement ranges/accuracy (±1 digit): pH/ion measurement: pH: -2.000 to +20.000/±0.004 -2.00 to +20.000/±0.01 mV: ±999.9/±0.2 ±2000/±1 Concentration: 0.001 mg/l to 200 g/l Temperature: automatic: -5.0 to +105.0°C NTC30 KOhm: ±0.1 K Pt 1000: ±0.1 K from 0.01% to 3.00%/K Conductivity measurement: 0.0 µS/cm to 2000 mS/cm in 5 ranges when in AutoRange mode 0.01 to 20.00 µS/cm (K=0.1 cm−1 ) 0.001 to 2.000 µS/cm (K=0.01 cm−1 ) Temperature: -5.0 to +105.0°C Salinity: 0.0 to 70.0 TDS: 0 to 2000 mg/l Spec. resistance: 0.00 to 2000 MOhm Conductance: ±0.5 % of measured value Temperature compensation -0.5 to +100°C manual: -20 to +130°C (linear and non-linear function for ultra-pure water and natural water (EN27888)) Deactivate compensation Reference temperature selectable: 20/25°C Cell constants fixed: 0.01 cm−1 freely adjustable: 0.090 to 0.110 cm−1 Calibration: 0.450 to 0.500 cm−1

Type

Description

inoLab⊃ pH/Ion/Cond 750

inoLab⊃ pH/Ion/Cond 750 SET

252

PK

Cat. No.

with 2 DIN inputs and broad range a.c. adapter (individual unit), without printer

1

9.774 396

inoLab⊃ pH/Ion/Cond 750 + SenTix 81 with DIN plugs including TetraCon 325

1

9.774 397

E & OE.


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Multi meters 1

265

1 Multi-parameter measuring instrument Lab 870 - Reliable and precise measuring values due to perfect matching with the measuring SI Analytics GmbH system. - fast pH measurment and calibration through advanced measuring algorithm. - maintains reliablity with "CalClock”, sensor recognition and calibration timer. - fast and easy documentation complying with GLP through perfect communication via USB (slave) and RS232 (except Lab 850) - highest safety for measuring and calibrating through wireless sensor recognition (Lab 870) ID electrodes and meters with automatic identification and data exchange and allocation. The special stand mounting with one click... and the stand is positioned firmly and safely. Items supplied in set: - measuring instrument - electrode with integrated temperature sensor - buffer solutions - stand - universal power supply unit - cover Specifications pH measuring range:

-2.000pH to +19.999pH -2.00pH to +19.99pH ±0.005 ±0.01 -999.9mV to +999.9mV; -999mV to +999mV ±0.3mV ±1mV -5.0°C to + 120.0°C 0.1°C

Accuracy (±1digit): mV measuring range: Accuracy (±1digit) Temperature measuring range: Accuracy (±1digit): Type Lab 870 DIN Set Lab 870 BNC Set

E & OE.

PK

Cat. No.

1 1

9.773 851 9.773 852

253


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Multi meters 1

2

9.773 864

9.773 866

1 2 Multi-parameter measuring instrument ProLab 1000/2000 - highest safety level with measurements and calibration through: automized user SI Analytics GmbH identification, user recognition with electronic ID card through wireless transponder technology - wireless sensor recognition ID electrodes and measuring instrument with automatic identification and data exchange and allocation - high-precision and reliable measurements through perfect matching with the measuring system. - safety at a glance with "CalClock”, Sensor evaluation and calibration timer - fast and easy documentation complying with GLP via USB (slave) and RS232 ports The special stand - mounting with one click...and the stand is positioned firmly and safely. Items supplied as set: - measuring instrument - electrode with integrated temperature sensor - buffer solutions - stand - universal power supply unit - cover

Specifications pH measuring range:

Accuracy (±1digit): mV measuring range: Accuracy (±1digit) Temperature measuring range: Accuracy (±1digit): Only ProLab 2000: ISE measuring range: Conductivity measurement O2 concentration

0.000 to 10000mg/l 0.000µS/cm to 2000mS/cm 0 to 20.00 mg/l x 0.01 mg/l

Type ProLab ProLab ProLab ProLab

254

272

-2.000pH to +20.000pH -2.00pH to +20.00pH -2.0pH to +20.0pH ±0.003 ±0.01 -1999.9mV to +1999.9mV; -1999mV to +1999mV ±0.2mV ±1mV -10.0°C to + 120.0°C 0.1°C

PK 1000 1000 2000 2000

DIN Set BNC Set DIN Set BNC Set

1 1 1 1

E & OE.

Cat. No. 9.773 9.773 9.773 9.773

864 865 866 867


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Multi meters 1 2 Multiparametermeters ProLab 3000/ProLab 4000

1

- "Windows" interface and operation SI Analytics GmbH - flexible display of measuring values on a high resolution, bright, backlit, colour-graphics display (320x240 pixels) - 2-channel pH/mV (galvanically isolated) inputs and dU differential measurement - ID electrodes with automatic identification and data exchange or allocation with the meter - automatic user identification with electronic identity card including password entry - recorder functions: display of measurement against time, scalable coordinate axis - numerical display of measurement value via mouse click (time, data, measurement value, temperature) - Interfaces: RS232C interface (bi-directional), USB connection (slave, bi-directional), USB master connection with direct connection (without configuration) to: USB-hub, USB-printer, USB-memory, keyboard, mouse, USB-stick

2 Specifications pH measuring range:

Accuracy (±1digit): mV measuring range: Accuracy (±1digit) ISE measuring range: Temperature measuring range: Accuracy (±1digit): ProLab 4000 only: Conductivity measuring range: Accuracy (±1digit):

-2.000 pH to +20.000pH -2.00 pH to +20.00pH -2.0 pH to +20.0pH ±0.002 ±0.01 -2200.0mV to +2200.0mV; -2200mV to +2200mV ±0.1mV ±1mV 1.0E−40 to 9.9E³9 mg/l -35.0°C to + 150.0°C 0.1°C 0.000µS/cm to 2000mS/cm 0.5 % from measurment value at an ambient temperature of 5°C to 30°C

Type ProLab ProLab ProLab ProLab

9.773 861

PK 3000 3000 4000 4000

DIN Set BNC Set DIN Set BNC Set

1 1 1 1

Cat. No. 9.773 9.773 9.773 9.773

857 859 861 863

3 Combined pH/conductivity/temperature testers

3

Simultaneous display of pH- and/or conductivity measurement value and temperature. Hanna Automatic temperature compensation of pH- and/or conductivity measurement gives enhanced accuracy. User selection of temperature coefficient enables use in alkaline and acidic media. Easy calibration with pre-programmed pH and conductivity solution values. Integral, robust, carbon conductivity probe. Exchangeable pH electrode HI 73127. Model HI 98130 features a very wide measuring range of 0 to 19.99 mS

Measuring ranges: pH: EC: TDS: °C: Accuracy: pH: EC/TDS: °C: Batteries: Ambient conditions: Weight:

0.0 to 14.0 0 to 3999 µS (HI 98129) 0 to 19.99 mS (only HI 98130) 0 to 2000 mg/l (HI 98129) 0 to 10.00 g/l (HI 98130) ±0.05 ±2% of the upper range value ±0.5 4 x 1.5 Volt 0 to 50.0°C 100 g

Type HI 98129 HI 98130

E & OE.

PK

Cat. No.

1 1

9.773 995 9.773 996

255


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Multi meters 1 Portable pH/ mV/ °C Meters HI8314N & HI83141

1

HI 8314N: supplied complete with plastic-bodied pH Electrode HI1217D with integral temperature sensor, calibration screwdriver, 9 Volt Battery.

Hanna

HI 83141: supplied complete with plastic-bodied pH Electrode HI1230B, separate temperature probe, calibration screwdriver, 9 Volt Battery.

Measuring range/Accuracy: pH: mV: °C: pH calibration: Temperature compensation: Dimensions: Battery type/operating life:

0.00 to 14.00/±0.01 0 to ±1999 (ORP)/±1 0.0 to 100.0/±0.4 manual, 2 point, through trimmers, (offset ±1 pH; slope 85 to 105%) automatic, 0 to 70°C (32 to 158°F) 185 x 82 x 45mm 1 x 9V/approx. 100 hours of continuous use

Type HI 8314N HI 83141

PK

Cat. No.

1 1

9.773 959 9.773 953

2 Laboratory pH meters, inoLab⊃ pH 730

2

Compact, with intuitive operation. WTW Precision pH/mV-meter with large multifunctional display for pH value and temperature, automatic temperature compensation, MultiCal⊃ calibration system with integral measurement memory, GLP-compliant documentation output facility and digital interface. Also available with built-in printer (paper width 112 mm) and document-quality thermal paper. Specifications: Measuring range/Accuracy: pH: mV: Temperature: Temperature compensation: AutoRead: Real-time clock: MultiCal⊃Automatic calibration:

265

Type

Description

inoLab pH 730 inoLab pH 730 set inoLab pH 730P inoLab pH 730P set

256

Calibration protocol: Memory: Output:

-2.000 to +19.999/±0.005 pH-units -2.00 to +19.99/±0.01 pH-units -999.9 to +999.9/±0.3 mV -1999 to +1999/±1 mV -5 to +105°C/±0.1 K -5 to +105°C automatic via TFK 150, TFK 325 or Pt1000, or -20 to +130°C on manual input of sample temperature For reproducibility higher than 0.02 pH-units Battery back-up using lithium battery, operational life > 10 years AutoCal: automatic 2-point calibration with DIN buffers AutoCal TEC: automatic 2-point calibration with WTW technical buffers ConCal: conventional 1/2-point calibration with any number of buffers GLP-conform logging of calibration, final log stored in memory 800 data records (measurements, temperature) bidirectional RS 232 (digital/analogue)

PK

Cat. No.

with serial interface

1

9.704 176

incl. multifunction box, pH electrode SenTix 41, accessories with additional built-in printer for GLP compliant documentation with built-in printer, incl. multifunction box, pH electrode SenTix 41, accessories

1

9.704 205

1

9.704 177

1

9.704 206

E & OE.


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Multi meters 1 Bench pH-/mV-/°C-Meters pH 211 and pH 213 -

1

Large LCD display Hanna displays pH/mV and Temperature simultaneously Stability indicator prevents unstable measurements automatic 2 point calibration with pre-programmed standard buffers (pH 7.01; 4.01; 10.01) automatic temperature compensation enables highest accuracy graphical symbols guide the user through the calibration and measurement procedures adjustable pH measurement resolution: 0.01 or 0.001 (pH 213 only) pH 213 is additionally supplied with RS 232 output to transfer data to PC pH 211 & pH 213 are supplied with HI 1131B glass pH electrode, temperature probe, electrode holder, pH 7.01 and 4.01 buffer solutions (20 ml each), electrolyte solution, 12 V d.c. power adapter

Ranges: pH: mV: °C: Accuracy: pH: mV: °C: Power supply: Operating temp. range: Weight:

0.00 to 14.00 ±400 (ISE); ±2000 (ORP) 0.0 to 100 ±0.01; ±0.002 (pH 213 only) ±0.2 (ISE); ±2 (ORP) ±0.5 12 V d.c. adapter (included) 0 to 50.0°C 3 kg

Type pH 211 pH 213

PK

Cat. No.

1 1

9.774 000 9.774 001

2 Bench pH Meter with Cal Check Function, HI221

2

Large, simultaneous, LCD display of pH or mV together with temperature. Automatic Hanna 2-point calibration with programmed standard buffers (pH 7.01; 4.01; 10.01). Graphic Symbols guide the user through calibration process and measurements Automatic or manual temperature compensation from -20°C to 120°C. Electrode condition and response time during calibration are indicated on the display. The meter compares the characteristics of the pH Electrode from one calibration to next. If there are large variances in the electrode condition, the user is alerted that the buffer might be contaminated or the electrode has to be cleaned (Calibration Check-Function). Calibration data (date, time, offset and slope) are memorised and can be checked at any time by simply pressing a button (GLP Functions). An alarm function alerts the user if a new calibration is required. By pressing the LOG button up to 100 values together with date and time can be stored in the memory. The data can downloaded to PC via RS232. Bench pH Meter Set: meter with pH glass electrode HI1131P, temperature probe, pH 7.01 & pH 4.01 buffer solutions (20 ml each), electrolyte solution, electrode holder, 12 Volt Adapter.

Measuring range/Accuracy: pH: mV: °C: Power supply: Operating temp. range: Weight:

-2.00 to 16.00/±0.01 ±699.9 (ISE); ±2000 (ORP)/ ±0.1 (ISE); ±1(ORP) -20.0 to 60.0/±0.4 12V d.c. adapter (included) 0 to 50°C 3 kg

Description Bench meter only Bench pH meter set

E & OE.

PK

Cat. No.

1 1

6.234 028 6.227 285

257


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Multi meters 1

1 Waterproof pH-/mV-/°C- Meters HI 9125 and HI 9126 -

rugged waterproof pH Meters Hanna pH or mV value and temperature are displayed simultaneously graphical symbols guide the user through calibration and measurement automatic one or two point calibration with pre-programmed standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) automatic or manual temperature compensation rechargeable batteries and inductive charger are supplied with the instrument additionally, HI 9126 displays the electrode status, 2 customs buffers can be programmed and the meter has a backlit display - HI 9125 & HI 9126 are supplied with plastic pH electrode, temperature probe buffer solutions pH 4.01 and 7.01 (20ml each), 4 x 1.2V AAA rechargeable batteries, inductive charger, all contained within a carrying case Specifications Range: pH mV °C Accuracy: pH mV °C Dimensions: Weight:

-2.00 to 16.00 -1999 to +1999 -20.0 to +120.0 ±0.01 ±1 ±0.4 192 x 72 x 36mm 525g

Type

PK

HI 9125 HI 9126 Spare electrode HI 1230B Temperature sensor, 1m cable

2

1 1 1 1

Cat. No. 9.773 9.773 6.050 9.773

978 979 012 960

2 Accessories for pH-/mV-/°C-meters pH 211 and 213 Hanna Type Electrode HI 1131B Calibration Kit pH 7.01 & 4.01 (5 x 20 ml each) Calibration Kit pH 7.01 & 10.01 (5 x 20 ml each)

3

PK

Cat. No.

1 1 1

9.040 993 9.773 932 9.773 934

3 Waterproof Multimeters HI991300/HI991301 pH or Conductivity (TDS) values are displayed together with temperature. Supplied with Hanna multi-parameter probe, all measurements can be taken without changing the probe. Automatic temperature compensation ensures high accuracy of the measurements. Automatic Calibration with preprogrammed pH buffer (pH 7.01; pH 4.01; pH 10.01) und Conductivity solutions 1413 µS (for HI 991300) or 12880 µS (for HI 991301). Graphic Symbols guide the user through Calibration and measurements. HI991300 and HI991301 are supplied complete with multi-parameter probe with 1 metre cable, 4 x 1.5 Volt batteries, all together in a carrying case.

Measurement range/Accuracy: pH: EC:

0.00 to 14.00/±0.01 0 to 3999µS/cm (HI991300) 0 to 20.00µS/cm (HI991301)/ ±2 % of the Measurement range 0 to 2000 mg/l (HI991300) 0 to 10.00 g/l (HI991301)/ ±2 % of the Measurement range 0.0 to 60.0

TDS:

°C: Resolution: pH: EC:

0.01 1µS/cm (HI991300) 0.01mS/cm (HI991301) 1mg/l (HI991300) 0.01g/l (HI991301) 0.1°C 4 x 1.5 Volt AAA 145 x 80 x 36mm 210g

TDS: °C: Batteries: Dimension: Weight: Type HI 991300 HI 991301

258

E & OE.

PK

Cat. No.

1 1

6.231 448 9.773 998


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/pH meters 1 pH tester, Checker 1

1

Pocket pH tester with exchangeable electrode. Ideal for pH testing small amounts of liquid and in narrow vessels. Specifications: Measuring range: Accuracy: Battery: Probe dimensions: Weight:

Hanna

0.00 to 14.00 pH ±0.2 pH 2 x 1.5 V cells 66 x 55 x 25 mm 63 g

Type

PK

Checker 1 Spare electrode Calibration kit, 5 x 20 ml pH 4 and pH 7 Calibration kit, 10 x 20 ml pH 7

1 1 1 1

2 Pocket pH meters, Piccolo

Cat. No. 9.773 9.773 9.773 9.773

930 931 932 933

2

Handy pocket pH meters with built-in amplifier electrode for greater measurement stability. Automatic temperature compensation via built-in temperature sensor. Two point calibration. Piccolo Plus model has additional temperature display. Supplied complete with electrode, batteries and buffer solutions in ABS case. Specifications: Measuring range: 0.00 to 13.00pH 0 to 70°C (Piccolo Plus only) Accuracy: ±0.01pH ±1°C (Piccolo Plus only) Batteries: 3 x 1.5V cells giving up to 100 hours operation Dimensions: 172 x 29 x 15mm Weight: 80g Type Piccolo I Piccolo II Piccolo Plus

Hanna

PK

Cat. No.

1 1 1

9.773 946 9.773 945 9.773 944

Spare electrodes for pH meters Piccolo Hanna Type

Length mm 90 160 160

HI 1280 Piccolo I HI 1290 Piccolo II HI 1295 Piccolo Plus

PK

Cat. No.

1 1 1

9.773 947 9.773 948 9.773 950

3 pH/°C tester pHep®-4

3

Recently developed waterproof pH °C tester (IP67). Hanna First pH tester with handheld measuring device features. Automatic two point calibration with 3 pre-programmed standard buffers (pH 7.01; pH 4.01; pH 10.01). Stability indicator for high-precision measurements. Simultaneous display of pH value and °C. Optional automatic or manual temperature compensation. Includes exchangeable HI 73127 pH electrode. Specifications: Measuring range: Accuracy: Batteries: Environmental conditions: Dimensions: Weight:

0.0 to 14.0 pH 0.0 to 60.0°C ±0.1 pH ±0.5°C 4 x 1.5 V 0 to +50°C 163 x 40 x 26 mm 100 g

Type

PK

pHep®-4 Spare electrode Calibration Kit pH 7.01 + 10.01, 5 x 20 ml Calibration kit pH 4.00 + 7.01, 5 x 20 ml

1 1 1 1

E & OE.

Cat. No. 9.773 9.773 9.773 9.773

920 921 934 932

259


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/pH meters 1

1 pH/°C Meter HI 991001 -

Portable pH/°C -Meter for laboratory use displays pH and temperature simultaneously stabilty Indicator prevents unstable measurements automatic 2 point calibration with pre-programmed standard buffers ( pH 7.01; 4.01; 10.01) automatic temperature compensation enables highest accuracy supplied with amplified pH Electrode HI 1296D with integral temperature sensor

Specifications: Measuring ranges: Accuracy: Battery: Operating temp. range: Weight:

-2.00 to 16.00 pH -5.0 to 105°C ±0.02 pH ±0.5°C 1x 9 Volt 0 to 50.0°C 500 g

Type HI 991001

2

Hanna

PK

Cat. No.

1

9.733 998

2 Accessories for pH-/°C- Meter HI 991001 Hanna Type Electrode HI 1296 D Calibration Kit pH 7.01 & 4.01 (5 x 20 ml each) Calibration Kit pH 7,01 & 10,01 (5 x 20 ml)

3

PK

Cat. No.

1 1 1

9.773 982 9.773 932 9.773 934

3 pH/Redox-Meter AL20pH The new, microprocessor-controlled, AL20, hand-held meter range meets the day-to-day AQUALYTIC requirement for sturdy and reliable systems to measure pH or redox, conductivity/TDS, temperature and dissolved oxygen. The water-tight housing complies with IP67 and is fitted with protective armouring to ensure reliable operation, even in extreme ambient conditions. The support can be flipped up to hang the meter on pipes or branches. -

battery operation period up to 15000 hours (4 x 1.5V type AA batteries) auto Hold function internal memory for 20 data sets 1/2 or 3-point-Calibration automatic buffer recognition sensor connections: DIN 19262 and two 4mm banana sockets "Temp" and "Ref" pH electrode: Gel-Type, plastic, with integral temperature sensor

Items supplied: AL20pH, lanyard, batteries and manual. AL20pH Set additionally with carrying case and electrodes.

Specifications: pH: Accuracy: Temperature: Accuracy: Redox (ORP): Redox (relative): Accuracy: Impedance: Input current: Nominal temperature: Operating temperature: Storage temperature: Power consumption: Auto off function:

0.00 to 14.00 ±0.01 pH at 25°C, ±1 sig. digit -10.0 to +110.0°C 14.0 to 230.0°F ±0.2°C (0 to 50°C, otherwise ±0.4°C) -1999 to +2000mV -1792 to +2206mV (DIN 38 404) ±0.1% fsd (mV or rel. mV) >101² Ω (typ.) <1 pA 25°C 0 to 50°C -20 to 70°C 0.2mA 0 to 120min

Type AL20pH Set AL20pH

260

E & OE.

PK

Cat. No.

1 1

9.699 260 9.699 261


GENERAL CATALOGUE 2010/11

3. Analytical measurement and testing Electrochemical meters/pH meters

Accessories for pH meter AL20pH AQUALYTIC Description

PK

pH-Electrode Redox electrode Lanyard Z 100 Carrying case, incl. foam insert

1 1 1 1

Cat. No. 9.699 9.699 9.699 9.699

262 263 252 253

1 pH meter Vario pH Ergonomic design, with a variety of uses

WTW

1

Attractive: as well as its eye-catching design, the new Vario has no buttons but an innovative touchscreen instead. All functions can easily be called up and set - with just one hand. A slight touch on the display suffices - and the Vario is ready to measure. Immersing the probe in the sample solution starts measurement automatically. The stable measurement value, including temperature, is easily legible on the large display; a Hold function freezes the display. GLP compliant memory stores up to 50 measurements for subsequent evaluation. But the Vario can do even more. Included in Vario Set accessories is an adapter which makes the device compatible with conventional precision electrodes. This allows the Vario to measure as accurately and reliably as a manual unit. If the Vario is not in use for pH measurements, it is useful as a lab clock or timer.

Specifications: Vario pH range: accuracy: Temperature measurement range: Automatic temperature compensation: Automatic buffer detection: Calibration points: Calibration alarm: Calibration date (GLP): Memory: AutoRead:

-2.00 to 16.00 pH ±0.01 pH -5.0 to 100.0°C yes TEC/NIST 3 (MultiCal®) yes yes 50 automatic AutoRead function Hold function to freeze measurement display

Description

PK

Cat. No.

Vario single unit including case, buffer 4/7

1

9.774 385

Vario Set 1 (case, DIN adapter, buffer 4/7 and SenTix 21) Vario Set 2 (case, DIN adapter, buffer 4/7 and SenTix 41) Vario Set 3 (case, S7 and DIN adapter, buffer 4/7 and SenTix 20)

1

9.774 386

1

9.774 387

1

9.774 388

Vario Set 4 (case, S7 and DIN adapter, buffer 4/7 and SenTix 60)

1

9.774 389

Vario Set 5 (case, short electrode including temperature probe, buffer 4/7)

1

9.774 392

Accessories for Vario pH meters WTW Description S7-Adapter DIN-Adapter Electrode with temperature sensor

E & OE.

PK

Cat. No.

1 1 1

9.774 393 9.774 394 9.774 395

261


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/pH meters 1 Pocket pH meters

1

The WTW ProfiLine, hand-held, pH/mV meters are robust and waterproof, according to WTW IP67. They have LCD or graphics displays. The proven DIN socket for connecting pH electrodes permits pH measurement even in wet environments. The instruments can be operated by standard alkaline or rechargeable batteries.

2 3 Portable pH meter pH 3110

2

Make testing simple. WTW Easy operation virtually eliminates errors. All function keys of the 3110 can be operated even when wearing gloves; automatic calibration and AutoRead functions ensure stable and reproducible results. The multifunctional display for pH, and temperature is always easy to read. Measuring ranges pH: Accuracy: mV:

3

Accuracy: Temperature: Accuracy: Temperature compensation:

Type

Description

pH pH pH pH

meter only case set including SenTix 21 and accessories case set including SenTix 41 and accessories case set including SenTix 81 and accessories

3110 3110 SET 1 3110 SET 2 3110 SET 3

-2.0 to +19.9 -2.0 to +19.9 ±0.01 pH (±1 digit) ±1200.0 ±2000 ±0.5 from +15°C to +35°C -5.0 to +105.0°C ±0.1K Automatic via pH electrodes with integral temperature probe, TFK 325 or Pt100

PK 1 1 1 1

Cat. No. 9.774 9.774 9.774 9.774

367 376 354 317

4 Portable pH meter pH 3210

4

Convenient and versatile pH/mV meter with backlit graphics display and menu controlled WTW operation. Waterproof and robust. With 5 point calibration for WTW technical or DIN/NIST buffers. Additional 16 pre-programmed buffer sets. The new CMC function (Continuous Measurement Control) helps maintain the optimum measuring range and warns when limits are exceeded.

Measuring ranges pH: Accuracy: mV: Accuracy: Temperature: Accuracy: Type

Description

pH pH pH pH

meter only case set including SenTix 41 and accessories case set including SenTix 81 and accessories case set including SenTix 51 and accessories

3210 3210 Set 2 3210 Set 3 3210 Set 4

262

-2.00 to +19.99 -2.000 to +19.999 ±0.005 from +15°C to +35°C ±1200.0 ±2500 ±0.3 from +15°C to 35°C -5.0 to +105°C ±0.1K PK 1 1 1 1

E & OE.

Cat. No. 9.774 9.774 9.774 9.774

377 355 318 319


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/pH meters 1 2 pH-Meter pH 3310

1

The pH/mV handheld meter with integral, time controlled, data logger and memory for WTW 5000 GLP compliant records is ideal for extended data collection. With 1 to 5-point pH calibration. Menu controlled, with backlit graphics display for comfortable and safe operation. Unique CMC-function for controlling the optimum measuring range. 100% waterproof, USB interface for fast data transfer. Includes driver software and cable.

Measuring ranges pH:

-2.0 to +19.9 -2.0 to +19.9 ±0.005 from +15°C to +35°C ±1200.0 ±2500 ±0.3 from +15°C to 35°C -5.0 to +105°C ±0.1K 5000 records (measured value, temperature, date, time, ID)

Accuracy: mV: Accuracy: Temperature: Accuracy: Memory:

Type

Description

pH pH pH pH

meter only case set including SenTix 41 and accessories case set including SenTix 81 and accessories case set including SenTix 51 and accessories

3310 3310 SET 2 3310 SET 3 3310 SET 4

2

PK 1 1 1 1

Cat. No. 9.774 9.774 9.774 9.774

337 356 375 329

Protective armouring for ProfiLine handheld meters SM Pro Soft rubber, shock absorbing cover for ProfiLine handheld meters

WTW

Type SM Pro

3 Storage and maintenance kit

PK

Cat. No.

1

9.774 118

3

Kit with one pH storage sleeve, technical buffer solution pH 4 and pH 7, 30ml KCl, 50ml cleaning and 50ml storage solutions. Type

WTW

PK

Cat. No.

1

9.774 117

4 Foodcare pH Meter HI 99161 with penetration electrode

4

The FC202D electrode supplied is highly suitable for measurements in Food products like Hanna fruit juices, yoghurt, butter, cheese and meat, due to its conical profile. It has a built in temperature sensor. pH and temperature are displayed simultaneously. With Stability indicator. Automatic 1- or 2point calibration with pre-programmed standard buffers (pH 4.01; 7.01; 10.01). Instrument is supplied with Foodcare Electrode FC202D, pH 7.01 & pH 4.01 buffer solutions (one sachet of 20 ml each), cleaning solutions (2 x 20 ml) 4 x 1.5 Volt batteries, all contained in a carrying case.

Measuring range/Accuracy: pH: °C: Battery type: Operating range: Weight:

0.00 to 14.00/±0.01 0.0 to 100.0/±0.4 4 x 1.5 Volt AAA 0 to 50°C 210g

Type HI 99161 E & OE.

PK

Cat. No.

1

6.233 767

263


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/pH meters 1 Laboratory pH meters, inoLab pH 720

1

Simple and reliable pH meter for routine use. Lab-pH/mV-meter with large multifunctional display for pH value and temperature, automatic temperature compensation, MultiCal® calibration system and battery power supply. Specifications: Measuring range/Accuracy (±1 digit): pH:

-2.000 to +19.999/±0.005 -2.00 to +19.99/±0.01 ±999.9/±0.3 ±1999/ ±1 0 to +105.0°C/±0.1 K automatic: -5.0 to +105.0°C manual: -20 to +130°C For reproducibility higher than 0.02 pH-units MultiCal®: automatic 3-point calibration with DIN buffers or WTW technical buffers ConCal: conventional 1/2-point calibration with any number of buffers

mV: Temperature: Temperature compensation: AutoRead: Calibration:

Type

Description

inoLab® pH 720 inoLab® pH 720 set

meter only incl. pH electrode SenTix 41 and accessories incl. pH electrode SenTix 81 and accessories

inoLab® pH 720 set

2

WTW

PK

Cat. No.

1 1

9.704 175 9.704 239

1

9.704 240

2 pH Meters, Lab 850 and 860 "CalClock" keeps your calibration under control: This unique combination of sensor evaluation and calibration timer monitors all calibration relevant parameters (buffer, electrode, curve slope, zero-point, time) and immediately indicates any errors. - keypad - clock - large LCD display - calibration interval adjustable - alarm

SI Analytics GmbH

Additional features Lab 860: - bi-directional RS 232C interface - USB connection - memory: 800 data records - GLP compliant Items supplied: pH meter Lab 850 or pH meter Lab 860, electrode BlueLine pH14 with temperature sensor, support, cover, power supply and DIN buffers 4.01 and 6.87

Specifications: Measuring range:

Temperature range: Calibration:

-2.00 to +19.999pH or -999.9 to +999.9mV and -1999 to +1999mV -5.0 to +120.0°C 1/2/3 point

Type Lab 850 Set Lab 860 Set

3

PK

Cat. No.

1 1

9.773 850 9.773 855

3 pH buffer solutions in sachets with certificate of analysis One 20ml sachet is sufficient for each calibration. Sachets are well sealed and protected against light. Single use only, so no risk of contamination. Accuracy: ±0.01 pH at 25°C. The outer box contains a certificate of analysis, showing the date of production and Lot Nr. (Expiry date). The solutions are produced again NIST standards. pHvalue at 25 °C pH 4.01 pH 7.01 pH 10.01

264

E & OE.

Hanna

PK

Cat. No.

25 25 25

6.803 609 6.803 610 6.803 611


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/pH meters 1 pH buffer solutions

1

Colored buffer solutions, standardized against NIST references, accuracy ±0.01 pH at 25°C, 500ml bottles with label that indicates correlation between pH-value and temperature. pHvalue at 25 °C pH 7.01 pH 4.01 pH 10.01 pH 7.01 pH 4.01 pH 10.01

Description

Hanna

PK

with certificate with certificate with certificate without certificate without certificate without certificate

1 1 1 1 1 1

Cat. No.

6.225 6.225 6.225 6.053 6.053 6.090

206 208 207 384 383 412

Storage and cleaning solutions Hanna Type Storage Solution, 500ml Cleaning solution, general purpose, 500ml Cleaning solution for proteins, 500ml

2 Pepsin cleaning solution PEP/pH

PK

Cat. No.

1 1 1

9.773 987 6.080 217 6.223 522

2

DIN. Supplied in bottles of 250 ml.

WTW

Type Pepsin cleaning solution*

PK

Cat. No.

3

9.040 796

3 pH combination electrodes, gel electrolyte, SenTix®

3

Basic pH combination electrodes, with gel electrolyte. Type

Connector

Cable

SenTix® 20 SenTix® 21 SenTix® 21-3 SenTix® 22 SenTix®41 SenTix® 41-3 SenTix®42

Plug-in head DIN, waterproof DIN, waterproof BNC DIN, waterproof DIN, waterproof BNC

m 1 3 1 1 3 1

WTW Int. temp. probe

PK

no no no no yes yes yes

1 1 1 1 1 1 1

Cat. No.

9.040 9.040 9.040 9.040 9.040 9.040 9.040

851 872 873 840 876 877 841

4

4 pH combination electrodes, liquid electrolyte, SenTix® Standard pH combination electrodes with non-solid electrolytes, length 120mm. Type

Connector

Cable

SenTix® 60 SenTix® 61 SenTix® 62 SenTix® 81 SenTix® 82

Plug head DIN, watertight BNC DIN, watertight BNC

m 1 1 1 1

Int. temp. probe

WTW PK

no no no yes yes

1 1 1 1 1

Cat. No.

9.040 9.040 9.040 9.040 9.040

842 881 843 886 844

5

5 pH combination electrode, liquid electrolyte, SenTix®H Precision pH combination electrodes with plug head. Length 165mm.

WTW

Description SenTix® H

E & OE.

PK

Cat. No.

1

9.040 845

265


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/pH meters 1

1 pH electrodes, SenTix® pH electrodes with plug head for special applications. Type

Description

SenTix® Sp SenTix® Sur SenTix® Mic

For penetration measurements For surface measurements pH micro combination electrode

WTW PK

Cat. No.

1 1 1

9.040 890 9.040 891 9.040 892

2 Electrode BlueLine 11 pH SCHOTT® Instruments pH combination electrode with glass body, Ag/AgCl reference system, cone membrane, platinum junction and screw head. LB 1A or LB 1BNC cable combination please order separately. Application: Universal use in chemical, pharmaceutical and food industries.

2

Specifications: Temperature range: pH range: Temperature sensor: Length/ Dia.: Electrolyte: Diaphragm: Membrane resistance at 25°C: Refill opening cover:

-5 to 100°C 0 to 14 pH No 120mm/12mm Liquid, KCl 3 mol/l Platinum 250Mohm Sliding cover

Type BlueLine 11 pH

266

SI Analytics GmbH

E & OE.

PK

Cat. No.

1

9.041 140



3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/pH meters 1

1 Electrode BlueLine 12 pH Generally as BlueLine 11 pH, but with 1 metre x 3 mm dia. fixed cable and DIN plug connection. Type BlueLine 12 pH

SI Analytics GmbH PK

Cat. No.

1

9.041 141

2 Electrode BlueLine 13 pH SCHOTT® Instruments pH-combination electrode with glass body, Ag/AgCl reference SI Analytics GmbH system and plug-in head. LB 1A or LB 1BNC cable combination please order separately. Applications: Universal use in chemical, pharmaceutical and food industries. Ideal for low ionic strength materials (Cremes, Emulsions, Dispersions and Suspensions).

2

Specifications: Temperature range: pH range: Temperature sensor: Length/Dia.: Electrolyte: Diaphragm: Membrane resistance at 25°C: Refill hole seal:

-5 to 100°C 0 to 14 pH No 170 mm/12 mm Fluid, KCl 3 mol/l Ground joint 300 M ohm Slide valve

Type BlueLine 13 pH

PK

Cat. No.

1

9.041 142

3 Electrode BlueLine 14 pH with temperature sensor 3

SCHOTT® Instruments pH-combination electrode with glass shaft, Ag/AgCl reference system and 1 metre x 5 mm dia. fixed cable, with DIN and 4 mm pin plug connections. Applications:Universal use in the chemical, pharmaceutical and food industries.

Specifications: Temperature range: pH range: Temperature sensor: Length/Dia.: Electrolyte: Diaphragm: Membrane resistance at 25°C: Refill hole seal:

-5 to 100°C 0 to 14 pH NTC 30 k ohm 120 mm/12 mm Fluid, KCl 3 mol/l Platinum 300 M ohm Slide valve

Type BlueLine 14 pH BlueLine 14 pH ID

4

PK

Cat. No.

1 1

9.041 143 6.233 381

4 Electrode BlueLine 15 pH As BlueLine 14 pH, but with built-in ATC, 1 metre long x 5 mm diameter fixed cable, BNC plug and 4mm banana plug. Type BlueLine 15 pH BlueLine 15 pH ID

268

SI Analytics GmbH

E & OE.

SI Analytics GmbH

PK

Cat. No.

1 1

9.041 144 9.041 155


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/pH meters 1 Micro Electrode BlueLine 16 pH

1

SCHOTT® Instruments micro-pH-combination electrode with glass body, Ag/AgCl reference system and plug-in head. LB 1A or LB 1BNC cable combination please order separately. Ideal for small sample volumes.

Specifications: Temperature range: pH range: Temperature sensor: Length // Dia.: Electrolyte: Diaphragm: Membrane resistance at 25°C: Refill hole seal:

SI Analytics GmbH

-5 to 100°C 0 to 14 pH No 40/80 mm // 12/5 mm Fluid, KCI 3 mol/l Platinum 300 M Ω Slide valve

Type BlueLine 16 pH

PK

Cat. No.

1

9.041 145

2 Spear-tip electrode, BlueLine 21 pH

2

SCHOTT® Instruments pH combination electrode with glass body, Ag/AgCl reference system, spear membrane tip and plug head. LB 1A or LB 1BNC cable combination please order separately. Particularly suitable for penetration measurements in semi-solid media. Specifications: Temperature range: pH range: Temperature sensor: Taper length // Dia. max./min. Electrolyte: Diaphragm: Membrane resistance at 25°C: Refill hole cover:

SI Analytics GmbH

-5 to + 80°C 2 to 13 pH No 65/25mm // 12/5mm Referid® Hole 400Mohm No refill hole

Type BlueLine 21 pH

PK

Cat. No.

1

9.041 146

3

3 Plastic bodied electrode, BlueLine 22 pH pH combination electrode with plastic body, Ag/AgCl reference system and plug head LB SI Analytics GmbH 1A or LB 1BNC cable combination please order separately. Use: Universal application in chemical, pharmaceutical and food industries, and in water/waste water plants and for field use.

Specifications: Temperature range: pH range: Temperature sensor: Length/Dia.: Electrolyte: Junction: Membrane resistance at 25°C: Refill hole cover:

-5 to 80°C 0 to 14 pH No 120 mm/12 mm Gel Fibre 400 M ohm No refill hole

Type BlueLine 22 pH

PK

Cat. No.

1

9.041 147

4

4 Electrode BlueLine 23 pH As BlueLine 22 pH, but with 1 metre long x 3 mm diameter fixed cable and DIN plug. Type BlueLine 23 pH

E & OE.

SI Analytics GmbH PK

Cat. No.

1

9.041 148

269


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/pH meters 1

1 Electrode, BlueLine 24 pH, with temperature sensor pH combination electrode with plastic body, Ag/AgCl reference system and 1 metre fixed SI Analytics GmbH cable with 5 mm DIN and 4 mm pin plug connections. Applications: Universal use, such as in water supply and effluent treatment departments of chemical, pharmaceutical and food factories and for field use. Specifications: Temperature range: pH range: Temperature sensor: Length/Ø: Electrolyte: Diaphragm: Membrane resistance at 25°C: Refill hole seal:

-5 to 80°C 0 to 14 pH NTC 30 Kohm 120 mm/12 mm Gel Fibre 400 Megohm No refill hole

Type BlueLine 24 pH

2

Type BlueLine 25 pH

Type BlueLine 26 pH

Specifications: Temperature range: pH range: Temperature sensor: Length/Dia.: Electrolyte: Diaphragm: Membrane resistance at 25°C: Refill opening:

SI Analytics GmbH PK

Cat. No.

1

9.041 150

SI Analytics GmbH PK

Cat. No.

1

9.041 151

SI Analytics GmbH

-5 to 50°C 2 to 13 pH no 120 mm/12 mm Referid® Annular space 400 Megohm No refill hole

Type BlueLine 27 pH

PK

Cat. No.

1

9.041 152

5 Redox (ORP) electrodes, BlueLine 31 RX SCHOTT® Instruments Redox combination electrode with glass body, Ag/AgCl reference system and plug head. LB 1A or LB 1BNC cable combination please order separately. Application: Universal applications in chemical and food industries. Specifications: Temperaturbereich: Sensor: Temperature sensor: Length/Dia.: Electrolyte: Junction: Membrane: Refill opening:

SI Analytics GmbH

-5 to 100°C Pt disc No 120 mm/12 mm liquid, KCl 3 mol/l Ceramic Platinum Sliding panel

Type BlueLine 31 RX

270

9.041 149

4 Electrode, BlueLine 27 pH, for surface measurements SCHOTT® Instruments pH-combination electrode with glass body, Ag/AgCl reference system and plug-in head. LB 1A or LB 1BNC cable combination please order separately. Specially suitable for surface measurements.

5

1

3 Electrode, BlueLine 26 pH, with temperature sensor As BlueLine 24 pH, but with built-in ATC, 1 m long, 5 mm dia. fixed cable, BNC plug and 4 mm banana plug.

4

Cat. No.

2 Electrode, BlueLine 25 pH As BlueLine 24 pH, but without temperature sensor and with 1 metre long, 3 mm dia. fixed cable, BNC plug.

3

PK

E & OE.

PK

Cat. No.

1

9.041 153


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/pH meters 1 2 electrodes, IoLine

1

pH electrodes for the most demanding measuring tasks

SI Analytics GmbH

The new Schott Instruments® IoLine electrode family with iodine/iodide reference system has been developed to meet the most demanding laboratory measurement tasks. These electrodes are 100% metal ion free and hence ideally suited for measurements that may cause sample contamination by such ions (e.g. silver ions) and for pH measurements in Tris buffers too. Advantages of IoLine Electrodes over classical Ag/AgCl reference systems are notably by: - longer service life thanks to a patented three-chambers Iodine reservoir in the reference electrode. - fast reaction, precise measurement and clearly improved stability of measurement values, especially with changing temperatures or at temperatures other than the calibration temperature. This is due to the lower temperature sensitivity of the iodine/iodide reference potential. - free choice of the bridge electrolyte, hence optimum adaptation to the sample by double electrolyte system. The electrodes are available in different membrane glass shapes and types and with different plugs to ensure that the user gets the instrument best suited to his needs. ID versions are available for use with Schott Instruments ProLab line of high-end laboratory meters.

2

IoLine electrodes are the right choice for the most critical pH measurements in research and quality control in pharmacy, biotechnology or food industry. Specifications: Temp. range Zero point pH range Shaft material Diaphragm:

-5 to 100°C pH = 7.00 ±0.25 0 to 14 Glass Platinum

Type IoLine-pHT-A IoLine-pHT-A IoLine-pHT-A IoLine-pHT-A IoLine-pHT-A

Length mm 120 170 120 120 170

120-MF* 170-MF* 120-MF-DIN 120-MF-DIN N** 170-MF-DIN N**

PK 1 1 1 1 1

Cat. No. 9.041 9.041 9.041 9.041 9.041

163 164 165 166 167

*S7 **banana plug

3 ID-Electrodes for pH measurement Schott® Instruments Specifications: shaft material Zero point pH range Fixed cable

3 SI Analytics GmbH

glass pH = 7.00 ±0.25 0 to 14 1m long, with DIN ( BNC plug available on request)

Type A 7780 1M-DIN-ID A 157 1M-DIN-ID

PK

Cat. No.

1 1

6.235 995 9.041 156

4 Cable combinations, LB 1 A and LB 1 BNC

4

For BlueLine pH electrodes, ScienceLine and IoLine.

SI Analytics GmbH

Type LB1-A LB1-BNC

PK

Cat. No.

1 1

9.041 303 9.041 304

5 6 Combination pH Electrodes

5 SI Analytics GmbH

Type Combination electrode N 6000 A Combination pH electrode N 1042 A

E & OE.

PK

Cat. No.

1 1

9.041 160 9.041 217

6

271


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/pH meters 1 Metal (ORP) electrodes, ScienceLine

1

SI Analytics GmbH Type Redox electrode Pt 6280 Electrode Ag 6280

PK

Cat. No.

1 1

9.041 207 9.041 211

2 pH-Electrodes ScienceLine

2

With plug head, glass shaft, ceramic diaphragm, 3 mol/l KCl electrolyte, 12mm dia. spherical membrane. pH range: 0 to 14

Type

Temp. range °C -5 to +100 -5 to +100 -5 to +100

N 6280, with plug head N 6180 N 42 A

Length

Material

mm 120 170 120

N-glass N-glass A-glass

SI Analytics GmbH

PK

Cat. No.

1 1 1

9.041 117 9.041 180 9.041 182

pH-combination electrodes With plug head, glass shaft, platinum diaphragm, 3 mol/l KCl electrolyte, Silamid® reference system and 12mm dia. spherical membrane. Type

N H N H N

61 61 62 62 64

3

Temp. range °C -5 to +100 +10 to +100 -5 to +100 -+10 to +100 -5 to +100

Length Material mm 170 170 120 120 170

SI Analytics GmbH PK

A-glass H-glass A-glass H-glass A-glass

1 1 1 1 1

Type

Connector

Cable

AS/DIN AS/DIN-3 AS/BNC

DIN DIN BNC

m 1 3 1

PK

Cat. No.

1 1 1

9.040 895 9.040 896 9.040 897

4 Electrode stand

Type Electrode stand

WTW PK

Cat. No.

1

9.040 870

5 KCL electrolyte solutions, test solutions For refilling or replacing reference electrolyte. Supplied in 250 ml Duran® bottles. Redox buffer solutions available on request. Type

SI Analytics GmbH

PK

2 mol/L KNO3 + 0.001 mol/l KCI for Ag-probes 3 mol/l KCl 3 mol/l KCI, Ag/AgCl saturated 4.2 mol/l KCl

272

100 105 110 112 120

WTW

With flexible electrode holder for two electrodes and temperature sensor.

5

9.041 9.041 9.041 9.041 9.041

3 Accessories for combination electrodes Connection cable for pH electrodes with plug head connection to plugs as indicated.

4

Cat. No.

E & OE.

1 1 1 1

Cat. No. 9.041 9.041 9.041 9.041

072 092 036 033


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/pH meters 1 Standard buffer solutions

1

To DIN/NIST. Supplied in 250 ml bottles.

WTW

pHvalue at 25 °C 4.01 6.87 9.18

PK

Cat. No.

1 1 1

9.040 744 9.040 746 9.040 749

Buffer solutions, sterile Steam sterilized. Individually batch numbered. With preservatives. Type

Capacity

pH 4.01 pH 6.87 pH 9.18

250ml Duran® bottle 250ml Duran® bottle 250ml Duran® bottle

SI Analytics GmbH PK

Cat. No.

1 1 1

9.041 004 9.041 007 9.041 009

Other buffer solutions available on request.

2 Technical buffer solutions

2

Identified by colour-coded labels. pHvalue

WTW

Capacity Type ml 50 1000 50 1000 1000 1000

4.01 4.01 7.00 7.00 10.00 10.01*

PK

STP 4 TEP 4 STP 7 TEP 7 TEP 10 TEP 10 TRACE

1 1 1 1 1 1

Cat. No.

9.040 9.040 9.040 9.040 9.040 9.040

734 722 735 723 724 725

*For handheld meters 315i, 330i, 340i, 350i, 3110, 3210, 3310 and Inolab 720, 730, 740 and 750.

3 pH buffer solutions

3

Without colour coding. Stated pH values at 25°C. Available in 250ml containers. Shelf life approx. 2 years, accuracy ±0.02 pH. Calibration set for pH measurement. Set contains 20 x 17 ml ampoules filled with pH 4.00, 7.00 and 10.00 solutions (at 25°C). Type

Capacity ml 250 250 250 17

pH 4,00 pH 7,00 pH 10.01 Set

Colour

SI Analytics GmbH

PK

clear clear clear 3 x 20 x 17 ml ampoules

1 1 1 1

Cat. No. 9.041 9.041 9.041 9.041

043 045 048 081

4 pH buffer solutions

4

Colour coded. pH values at 25°C. Provided with label that gives the pH value at different temperatures. Supplied in 250ml containers. Shelf life approx. 2 years. Tolerance ±0.02 pH. Type pH 4.01 pH 7.00 pH 10.01

Capacity ml 250 250 250

SI Analytics GmbH

Colour

PK

Cat. No.

yellow green orange

1 1 1

9.041 050 9.041 051 9.041 052

Regeneration solution and storage solution For pH-probes Type Regeneration solution / Storage solution

SI Analytics GmbH Capacity ml 250

5 Calibration and maintenance solution set SORT/K

PK

Cat. No.

1

9.041 034

5

Supplied in box with three 250 ml bottles of pH 4.01, 6.87, 9.18 buffer solutions, pepsin cleaning solution and KCl filling solution 3 mol/l. Type SORT/K

E & OE.

WTW

PK

Cat. No.

1

9.040 760

273


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/pH meters 1

1 Redox buffer solution For testing ORP electrodes. 427 mV, pH7. Supplied in pack of 250ml. Type Redox

2

WTW PK

Cat. No.

1

9.040 782

2 Test strips, Aquadur® For determining water hardness. Supplied in boxes of 100 strips. Scale gradation °d* 0, 5, 10, 15, 20, 25 0, 4, 7, 14, 21 0, 4, 8, 4, 14

MACHEREY-NAGEL PK

Cat. No.

100 100 100

9.130 393 9.130 394 9.130 400

* German units. Multiply by 1.25 to convert to UK units (°e), and by 10 for US units (mg/l CaCO3)

3

3 Litmus paper Litmus paper, available in blue, red and neutral. Supplied in books of 100 strips, 10 x 75 mm W x L. Type Litmus paper, blue Litmus paper, red Litmus paper, neutral

4

Range

Cat. No.

1 1 1

9.130 112 9.130 116 9.130 118

MACHEREY-NAGEL

PK

pH 0.5 to 5.5 5.5 to 9.0 1 to 11 1 to 14

1 1 1 1

Refill packs universal contain 3 rolls. Range

Cat. No.

9.130 9.130 9.130 9.130

305 325 200 210

MACHEREY-NAGEL PK

pH 0.5 to 5.5 1 to 11 1 to 14 5.5 to 9.0

3 3 3 3

Cat. No.

9.130 9.130 9.130 9.130

306 203 213 326

5 Indicator paper, Duotest Roll length 5 m, 10 mm width. With two colour zones. Plastic box with 1 roll of indicator paper and colour scale. Range

MACHEREY-NAGEL

PK

pH 1 to 12 1.0 to 4.3 3.5 to 6.8 5.0 to 8.0 7.0 to 10.0 9.5 to 14.0

274

PK

4 Universal indicator papers For determination of pH- value. Plastic dispensing reel with 1 roll of indicator paper and colour scale.

5

MACHEREY-NAGEL

1 1 1 1 1 1

E & OE.

Cat. No.

9.130 9.130 9.130 9.130 9.130 9.130

344 356 359 347 362 363


GENERAL CATALOGUE 2010/11

3. Analytical measurement and testing Electrochemical meters/pH meters

1

Refill packs Duotest contain 3 rolls.

MACHEREY-NAGEL

Range

PK

Cat. No.

pH 1 to 12 5 to 8

3 3

9.130 355 9.130 358

2 Universal indicator paper, Tritest

1

2

For determination of pH- value. Roll length 5 m, 10 mm width. With three colour zones, without hydrophobic zone. Plastic container with 1 roll of indicator paper and colour scale.

MACHEREY-NAGEL

Range

PK

Cat. No.

pH 1 to 11

1

9.130 367

3 Universal indicator paper Tritest L

3

For determination of pH- value. Roll length 6 m, 14 mm width. With three colour zones and 2 hydrophobic zones. Plastic container with 1 roll of indicator paper and colour scale.

MACHEREY-NAGEL

Range

PK

Cat. No.

pH 1 to 11

1

9.130 360

Refill packs Tritest L contain 3 rolls.

MACHEREY-NAGEL

Range

PK

Cat. No.

pH 1 to 11

3

9.130 361

Refill packs Tritest contain 3 rolls.

MACHEREY-NAGEL

Range

PK

Cat. No.

pH 1 to 11

3

9.130 368

4 Indicator paper, Pehanon速

4

For determination of pH- value. Supplied in packs of 200, 11 x 100mm W x L strips.

MACHEREY-NAGEL

Range

PK

pH 1 to 12 0 to 1.8 1.0 to 2.8 1.8 to 3.8 2.8 to 4.6 3.8 to 5.5 4.0 to 9.0 5.2 to 6.8 6.0 to 8.1 7.2 to 8.8 8.0 to 9.7 9.5 to 12.0 10.5 to 13.0 12.0 to 14.0

200 200 200 200 200 200 200 200 200 200 200 200 200 200

E & OE.

Cat. No.

9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130

657 658 651 652 656 603 659 605 626 660 366 661 663 666

275


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/pH meters 1

1 pH-Fix indicator strips For determination of pH- value. Permanent colour. Non bleeding.

MACHEREY-NAGEL

Range

PK

pH 0 to 14.0 0 to 6.0 2.0 to 9.0 4.5 to 10.0 6.0 to 10.0 7.0 to 14.0 3.6 to 6.1 5.1 to 7.2 6.0 to 7.7 7.5 to 9.5 7.9 to 9.8 0 to 14.0*

100 100 100 100 100 100 100 100 100 100 100 100

Cat. No.

9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130

381 382 380 383 392 384 387 388 389 390 391 379

*PlopTop tube

2

2 pH indicator strips Non-bleeding. Ranges as indicated. Supplied in packs of 100 strips.

3

Type

Range

Universal Acilit Neutralit Alkalit

pH 0 to 14 0 to 6 5 to 10 7.5 to 14

Merck

Increments

PK

pH units 1 0.5 0.5 0.5

100 100 100 100

Cat. No.

9.130 9.130 9.130 9.130

001 016 017 018

3 Special indicator strips Non-bleeding. Supplied in packs of 100 strips. Range pH 0.0 to 2.5 2.0 to 9.0 2.5 to 4.5 4.0 to 7.0 5.2 - 7.2 6.5 to 10.0 11.0 to 13.0

276

Merck

Increments

PK

pH units 0.3 to 0.5 0.5 0.2 to 0.5 0.2 to 0.5 0.1 to 0.3 0.2 to 0.5 0.2 to 0.5

100 100 100 100 100 100 100

E & OE.

Cat. No.

9.130 9.130 9.130 9.130 9.130 9.130 9.130

002 003 004 007 008 010 013


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/pH meters 1 Quantofix® test strips For semi-quantitative determinations. Strips 6mm wide x 95mm long. Supplied in packs of 100 strips.

MACHEREY-NAGEL

For

Measuring range

Aluminium* Ammonia* Arsenic 50* Arsenic 10* Ascorbic acid Calcium** Carbon hardness Chlorine* Chloride Chromate* Cyanide* EDTA Iron 1000* Iron 100* Formaldehyde* Potassium* Cobalt Alkalinity of cooling lubricant

5 to 500 mg/l Al3+ 10 to 400 mg/l NH4+ 0.05 to 3.00 mg/l As3+/5+ 0.01 to 0.50 mg/l As3+/5+ 50 to 2000 mg/l 10 to 100 mg/l Ca2+ 0 to 20 °d 1 to 100 mg/l Cl2 0 to 3000 mg/l Cl3 to 100 mg/l CrO421 to 30 mg/l CN100 to 400 mg/l EDTA 5 to 1000 mg/l Fe2+/3+ 2 to 100 mg/l Fe2+/3+ 10 to 200 mg/l HCHO 200 to 1500 mg/l K+ 10 to 1000 mg/l Co2+ 15 to 200 mmol/l KOH

100 100 100 100 100 60 100 100 100 100 100 100 100 100 100 100 100 100

9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130 9.130

401 414 415 416 402 417 418 419 420 403 421 432 404 405 422 423 406 434

Copper Molybdate* Nickel Nitrate/Nitrite

10 to 300 mg/l Cu2+ 5 to 250 mg/l Mo6+ 10 to 1000 mg/l Ni2+ 10 to 500 mg/l NO3-, 1 to 80 mg/l NO21to 80 mg/l NO2100 to 3000 mg/l NO250 to 1000 mg/l H2O2 1 to 100 mg/l H2O2 0.5 to 25 mg/l H2O2 3 to 100 mg/l PO4310 to 1000 mg/l Quat

100 100 100 100

9.130 9.130 9.130 9.130

407 424 408 409

100 100 100 100 100 100 100

9.130 9.130 9.130 9.130 9.130 9.130 9.130

410 425 426 411 427 428 433

200 to 1600 mg/l SO4210 to 1000 mg/l SO322 to 100 mg/l Zn2+ 10 to 500 mg/l Sn2+

100 100 100 100

9.130 9.130 9.130 9.130

429 412 430 413

Nitrite Nitrite 3000 Peroxide 1000 Peroxide 100 Peroxide 25 Phosphate* Quaternary ammonium compounds Sulphate Sulphite Zinc* Tin

PK

Cat. No.

*Test strips with reagent **Box with 60 test strips and reagent

1

E & OE.

277


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/pH meters-Conductivity meters 2

1

1 2 Merckoquant test strips Merck

3

For

Measuring range

PK

Cat. No.

Aluminium Ammonia Ascorbic acid Lead Calcium Chromate Cobalt Cyanide Iron Formaldehyde Total hardness Total hardness Total hardness Total hardness Potassium Copper Manganese Molybdenum Nickel Nitrate Nitrite Nitrite Peracetic acid

10 to 250 mg/l Al3+ 10 to 400 mg/l NH4+ 50 to 2000 mg/l 20 to 500 mg/l Pb 10 to 100 mg/l Ca2+ 3 to 100 mg/l CrO4210 to 1000 mg/l Co2+ 1 to 30 mg/l CN3 to 500 mg/l Fe2+/3+ 10 to 100 mg/l HCHO 5 to 25 °dH 3 to 21 °dH 3 to 21°dH 4 to 21 °dH 250 to 1500 mg/l K+ 10 to 300 mg/l Cu2+ 2 to 100 mg/l Mn 5 to 250 mg/l Mo6+ 10 to 500 mg/l Ni2+ 10 to 500 mg/l NO3-, 2 to 80 mg/l NO20.1 to 3 mg/l NO25 to 50 mg/l

100 100 100 100 60 100 100 100 100 100 100 100 1000 5000 100 100 100 100 100 100 100 100 100

9.129 9.129 9.129 9.129 9.129 9.129 9.129 9.129 9.129 9.129 9.129 9.129 9.129 9.129 9.129 9.129 9.129 9.129 9.129 9.129 9.129 9.129 9.129

901 902 904 905 907 909 911 912 913 914 916 918 919 921 922 923 926 927 928 931 932 933 943

Peroxide Silver Sulphate Sulphite Zinc Tin

0.5 to 25 mg/l H2O2 0.5 to 10 mg/l Ag 200 to 1600 mg/l SO4210 to 400 mg/l SO3210 to 250 mg/l Zn2+ 10 to 200 mg/l Sn2+

100 100 100 100 100 50

9.129 9.129 9.129 9.129 9.129 9.129

934 936 937 938 941 942

3 Conductivity testers, DIST Pocket measuring device with digital display for testing the conductivity in drinking water and industry

Hanna

DIST 3: suitable for measuring drinking water, reverse osmosis monitoring and in the laboratory. DIST 4: ideal for measurements required in industry, horticulture, sewage, cooling towers.

Specifications: Measuring range: Resolution: Accuracy: Batteries: Dimensions: Weight:

DIST 3/3 WP: 0 to 1990 µS DIST 4/4 WP: 0 to 19.90 mS DIST 3/3 WP: 1 µS/cm DIST 4/4 WP: 0.01 mS ±2% measuring range 4 x 1.5 V button cells (MP 675H) 145 x 41 x 23 mm 78 g

Type DIST 3 DIST 4

278

E & OE.

PK

Cat. No.

1 1

9.704 010 9.704 014


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Conductivity meters 1 Conductivity meter HI 8733N -

1

Multi range conductivity meter for laboratory use can be used for various applications from deionized water to brine automatic temperature enables highest accuracy for various strong acids or bases the temperature coefficient can be adjusted between 0% and 2% per °C instrument is supplied with 4-ring, potentiometric probe for all 4 ranges

Specifications: Ranges:

Accuracy: Temperature compensation: Calibration: Battery: Operating temp. range: Weight:

Hanna

0.00 to 199 µS 0 to 1999 µS 0 to 19.99 mS 0 to 199.9 mS ±1% Full Scale automatic from 0 to 50°C manual single point trough trimmer 1 x 9 Volt 0 to 50°C 500 g

Type HI 8733N

PK

Cat. No.

1

9.704 016

2 Conductivity solutions for Conductivity meter HI 8733

2 Hanna

Type

PK

12880 µS 1413 µS 84 µS 80.000 µS

1 1 1 1

Cat. No. 9.704 9.704 9.773 9.773

017 018 992 993

3 Determining Conductivity Meter 970

3

- reliable and precise measurements due to perfect matching with the measuring SI Analytics GmbH system. - fast and easy documentation complying with GLP through perfect communication via USB (slave) and RS232 - measuring acc. to USP28 - complete support including IQ and OQ documentation and qualified service. - ultimate reliability for measurement and calibration by wireless sensor recognition (Lab 970) ID electrodes and meters with automatic identification and data exchange and allocation. The special stand - mounts with one click... and the stand is firmly and securely positioned. Items supplied in set: - meter - conductivity cell - conductivity testing solution - stand - universal power supply unit - cover Specifications Conductivity measuring range: Accuracy (±1digit): Temperature measuring range: Accuracy (±1digit):

0.000 µS/cm to 500mS/cm ±0.5 -5.0°C to + 120.0°C 0.1°C

Type Lab 970 Set

E & OE.

PK

Cat. No.

1

9.773 853

279


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Conductivity meters 1 Conductivity testers, Dist 5 and Dist 6

1

Watertight pH-/ conductivity-/ TDS- /°C-testers. Simultaneous display of conductivity Hanna and/or TDS and temperature values. Automatic temperature compensation for highest measuring accuracy. User selection of temperature coefficient enables use in alkaline and acidic media. Stability indicator prevents incorrect measurements

Specifications: Measuring range:

DIST 5 : 0 to 3990 mS (0 to 2000 ppm) DIST 6 : 0 to 20.00 mS (0 to 10.00 ppm) 0.0 to 60.0°C ±2% in each measuring range ±0.5°C 4 x 1.5 V button cells 0 to 50.0°C 100 g

Temperature range: Resolution EC/TDS: Resolution: Batteries: Operating temp. range: Weight: Type

PK

Cat. No.

Dist 5 Dist 6

1 1

9.704 012 9.704 013

2 Pocket conductivity meters

2

The new ProfiLine hand-held conductivity meters have a waterproof (IP 67) housing and WTW a new, completely sealed silicone membrane keypad with tactile feedback. A separate battery compartment allows easy exchange of standard alkaline, or rechargeable, batteries. The carefully laid out, large displays indicate the reading and other important information. 3210 and 3310 series meters have a backlit, graphics display and menu-controlled operation. A selection of application specific conductivity cells cover virtually all measurement tasks.

3 4 Conductivity cell probes

3

TetraCon® 325 standard conductivity cell probe: 4-pole cell with integral temperature sensor. Cable length 1.5 metres. Measuring range: 1µS/cm to 2S/cm.

4

WTW

TetraCon® 325/Pt high performance conductivity cell probe: 4-pole glass cell probe with integral temperature sensor. Universally applicable, even in partially aqueous and highly aggressive media. Cable length 1.5 metres. Measuring range: 1µS/cm to 1S/cm. LR 325/01 ultra-pure water conductivity cell probe: With integral temperature sensor and flowthrough vessel D 01/T for measuring very low conductivity ranges (<1 mS/cm) e.g. boiler feed water or deionised water. Cable length 1.5 metres. Min./max. insertion depth 35/110mm and flowthrough, measuring range: 0.001mS/cm to 200mS/cm. TetraCon® DU/T conductivity flowthrough cell: 4-pole conductivity cell with integral temperature sensor for standard applications. Connection via 10mm diameter tubing nozzles (the adapter cable KKDU with 1 metre cable is required for connection). Filling volume 7ml. Measuring range: 1mS/cm to 2S/cm.

Type

Electrode

Shaft diameter

TetraCon® 325

Graphite

Epoxy resin

LR 325/01 TetraCon® DU/T

V4A steel Graphite

V4A steel Epoxy resin

KKDU 325

Connection cable

-

280

Length Cell constant mm 120 K =0,475

PK

Cat. No.

1

9.704 081

121 K = 0.1 155 K = approx. 0.8

1 1

9.704 083 9.704 078

100 -

1

9.704 079

E & OE.


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Conductivity meters 1 2 Conductivity meter Cond 3310

1

Comfortable and versatile conductivity meter with integral, time controlled, data logger WTW and 5000 GLP-compliant record memory for extended data collection. Menu controlled, with backlit, graphics display for comfortable, safe operation. Wide range of conductivity cells attachable. GLPsupporting functions, enhanced choice of cell constants, automatic and manual temperature compensation (which can be switched off) with linear and non-linear functions for pure water and natural waters acc. to EN 27888.

Specifications: Conductivity: Conductivity: TDS: Spec. resistance: Memory:

0.000µS/cm to 1.999µS/cm (at K=0.01 cm -1) 0 bis 1999 mg/l, 0.0 to 199.9 g/l 0.00 to 1999 MΩ /cm 5000 records (measured value, temperature, date, time, ID)

Type

Description

Cond 3310 Cond 3310 SET 1

meter only case set including conductivity probe TetraCon 325 and accessories case set including 4-pole conductivity probe TetraCon 325 (3m) and accessories case set including 2-pole conductivity probe LR 325 / 01and accessories

Cond 3310 SET 2 Cond 3310 SET 4

3 4 Portable conductivity meter Cond 3110

2

PK

Cat. No.

1 1

9.774 409 9.774 400

1

9.774 401

1

9.774 402

PK

Cat. No.

3

Easy to operate rugged conductivity meter for measurement of conductivity and salinity. WTW Simplified keypad for clear and secure operation. Simultaneous display of measurement value and temperature. Large LCD display for easy reading. Automatic nlF compensation for all grades of natural water. Works with four-electrode cell TetraCon® 325 or two-electrode cell KLE 325. Specifications: Measuring ranges/Resolution Conductivity: Temperature: Salinity: Tref:

0.0 µS/cm to 500 mS/cm with 5 measuring ranges in the Auto Range mode 0.0 to 70.0 20°C/25°C switchable

4

Type Cond Cond Cond Cond

Description 3110 3110 SET 1 3110 SET 2 3110 SET 3

meter only cased set including conductivity probe TetraCon 325 and accessories cased set including conductivity probe TetraCon 325 (3m) and accessories cased set including conductivity probe KLE 325 and accessories

E & OE.

1 1 1 1

9.774 9.774 9.774 9.774

372 358 403 404

281


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Conductivity meters 1 Portable conductivity meter Cond 3210

1

Convenient and versatile, hand-held, conductivity meter with backlit graphics display WTW and menu-controlled operation. Waterproof and robust. For the measurement of conductivity, specific resistivity, salinity and TDS. Includes a 200 x GLP-compliant record memory. Wide selection of different conductivity cells attachable. Automatic and manual temperature compensation with linear temperature function and non-linear function for ultra-pure water and natural water in accordance with EN 27888. Specifications: Measuring ranges/Resolution (as Cond 3110, but additionally with): Conductivity: TDS: Spec. resistance: Memory:

Type

Description

Cond 3210 Cond 3210 SET 1

0.00µS/cm to 19.99µS/cm (when K = 0.1 cm-1) 0.0 to 1000mS/cm 0 to 1999mg/l, 0.0 to 199g/l 0.0 to 20MΩ/cm 200 data records (measured value, temperature, date, time, ID)

PK

Cat. No.

meter only cased set including conductivity probe TetraCon 325 and accessories

1 1

9.774 379 9.774 398

Cond 3210 SET 2

cased set including 4-pole conductivity probe TetraCon 325 (3m) and accessories

1

9.774 405

Cond 3210 SET 4

cased set including 2-pole conductivity probe LR 325 / 01and accessories

1

9.774 399

2

2 Vario Cond Set conductivity instrument The Vario Cond has a lot to offer. This instrument was designed with ergonomic WTW requirements in mind. It is ideal for service work and inspection measurements on process equipment. The TetraCon® 325 measuring cell, recognised around the world, was shortened and modified especially for the Vario Cond. If that is not enough; an adapted ultra-pure water cell with plug-in head and flowthrough vessel can also be used with the Vario Cond. Specifications: Measurement range/Resolution Conductivity: Temperature: Salinity: TDS: Spec. resistance: Accuracy (±1 digit) Conductivity: Temperature: Reference temp. (Tref): Cell constant: Temperature comp.: Temperature coefficient:

±0.5 % of measurement ±0.1 K selectable 20°C or 25°C fixed 0.475 cm-1, 0.1 cm-1 automatic or switched off - non-linear function of natural water (nLF) per EN 27888 and ultra-pure water function - linear compensation of 0.01 to 2.99 %/K - no compensation

Type

Description

2X00-001A

incl. transport case, TetraCon® 325 and KCL solution incl. transport case and LR 01/V

2X00-001B

282

0.0 µS/cm to 200 mS/cm -0.5 to +105.0°C 0.0 to 70.0°C 0 to 1999 mg/l 0.000 to 1999 Mohm/cm

E & OE.

PK

Cat. No.

1

9.774 390

1

9.774 391


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Conductivity meters 1 Laboratory conductivity meter inoLab® Cond 720

1

Simple and reliable. WTW Routine laboratory application conductivity meter with large multifunctional display, simultaneous temperature display and automatic temperature compensation. Reference temperatures of 20°C or 25°C can also be manually set. TDS and salinity can also be measured in addition to conductivity and temperature. Adjustment to various cell constants is possible using the TetraCon®325 4-point measuring cell which is suitable for connection to the ultrapure water measuring cell LR 325/01 and other specialised measurement cells. Specifications: Measuring range/Resolution Conductivity:

0.0 µS/cm to 500 mS/cm in 5 measuring ranges or AutoRange: additionally for K = 0.1; 0.00 to 19.999 µS/cm -5.0 to +105°C 0.0 to 70.0 20°C/25°C switchable 300 x 250 x 70 mm

Temperature: Salinity: Tref: Dimensions (WxDxH): Type

Description

inoLab® Cond 720 inoLab® Cond 720 Set

meter only incl. conductivity probe TetraCon 325 and accessories

2 Laboratory conductivity meter inoLab Cond 730

PK

Cat. No.

1 1

9.704 188 9.704 214

PK

Cat. No.

1 1

9.704 189 9.704 208

1

9.704 190

1

9.704 209

2

Compact, with intuitive operation. WTW Standard laboratory conductivity meter with large multifunctional display, simultaneous temperature display and automatic temperature compensation. Integral measurement memory with logger function and real-time clock permits GLP-compliant documentation output. Also available with built-in thermal printer (paper width 112 mm) with document-quality printout. Reference temperatures of 20°C or 25°C can be manually set. TDS and salinity can also be measured in addition to conductivity and temperature. Adjustment to various cell constants is possible using the TetraCon® 325 4-point measuring cell which is suitable for connection to the ultrapure water measuring cell LR 325/01 and other specialised measurement cells. Specifications: Measuring range/Resolution:

Interface: Dimensions (WxDxH):

Conductivity: 0.0 µS/cm to 500 mS/cm in 5 measuring ranges or AutoRange: additionally for K = 0.1; 0.000 to 19.999 µS/cm Temperature: -5.0 to +99.9°C Salinity: 0.0 to 70.0 TDS: 0 to 1999mg/l Self-configuring as analogue output or bidirectional RS 232 interface 300 x 250 x 70 mm

Type

Description

inoLab® Cond 730 inoLab® Cond 730 Set

with serial interface incl. multifunction box, conductivity probe TetraCon 325, accessories as 9.704 189 but with integral printer for GLP-compliant documentation with integral printer, incl. multifunction box, conductivity probe TetraCon 325, accessories

inoLab® Cond 730 inoLab Cond 730P Set ®

E & OE.

283


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Conductivity meters 1 Laboratory conductivity meter inoLab®Cond 740

1

Flexible and powerful. WTW Research level meter with graphics display and digital recorder function, simultaneous temperature display and automatic temperature compensation. With integral measurement memory, logger function, real-time clock and optional built-in printer (thermal paper) guaranteeing GLP-compliant documentation. Reference temperatures of 20°C or 25°C can be manually set. TDS and salinity can also be measured in addition to conductivity and temperature. Adjustment to various cell constants is possible using the TetraCon®325 4-point measuring cell which is suitable for connection to the ultrapure water measuring cell LR 325/01 and other specialised measurement cells. A PC keyboard interface is provided for connection to external keyboard or barcode reader. Can be controlled directly from the user's PC using software included. InoLab® Cond 740 has integrated all measurement functions and cable connections in its intelligent multifunction controller. In addition the measuring process is triggered directly from the cell stand.

Specifications: Measuring range/Resolution:

Interface: Dimensions (WxDxH):

Conductivity: 0.0 µS/cm to 2000 mS/cm in 5 measuring ranges or AutoRange: additionally for K = 0.1; 0.000 to 20.00 µS/cm Temperature: -5.0 to +99.9°C Salinity: 0.0 to 70.0 TDS: 0 to 2000mg/l Self-configured for analogue output or bidirectional RS 232 interface 300 x 250 x 70 mm

Description

PK

Cat. No.

1

9.704 191

multifunction controller, universal interface and integral printer

1

9.704 192

multifunction controller, universal interfaceTetraCon 325, 4-point conductivity measuring cell and accessories

1

9.704 193

multifunction controller, universal interfaceTetraCon® 325, integral printer 4-point conductivity measuring cell and accessories

1

9.704 194

multifunction controller, universal interface

®

2 Conductivity meter HI 9033

2

Waterproof housing, perfect for laboratory and field work.

Hanna

- 4 different ranges from 0 to199.9 mS can be selected by simply pressing a button - automatic temperature compensation grants highest accuracy - manual calibration at 1 point trough trimmer Supplied in a transport case, complete with 4 ring conductivity probe with 1 metre cable, calibration screwdriver and battery. Specifications: Measuring range/Resolution: 0.0 to 199.9µS/0.1µS 0 to 1999 µS/1 µS 0 to 19.99 mS/0.1 mS 0 to 199.9 mS/1 mS Accuracy: ±1% full scale Temperature compensation: automatically from 0 to 50°C Operating range: 0 to 50°C Battery: 1 x 9V Weight: 1 kg (incl. transport case) Type HI 9033

PK

Cat. No.

1

6.095 234

Conductivity solutions Values stated at 25°C. Supplied in containers as indicated. Accuracy ±2%. Type 147µS/cm* 12.9mS/cm* 1413µS/cm

SI Analytics GmbH

Capacity ml 17 17 250

* Supplied in vials!

284

E & OE.

PK

Cat. No.

18 18 1

9.041 053 9.041 055 9.041 056


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Conductivity meters 1 Conductivity Meter AL20Con Set

1

The new, microprocessor-controlled, AL20 hand-held meter range meets the day-to-day AQUALYTIC demand for sturdy and reliable sytems for the measurement of pH or redox, conductivity/TDS, temperature and dissolved oxygen. The water-tight housing complies with IP67 and is fitted with protective armouring to ensure reliable operation, even in extreme ambient conditions. The support can be flipped up to hang the meter on pipes or branches. -

battery operation period up to 3000 hours (4 x 1.5V type AA batteries) auto Hold function internal memory for 20 data sets 1-point calibration in the range 1000 to 2000 µS/cm temperature compensation selectable: linear (0.3 to 3.0 /K), non-linear (in acc. with EN 27 888) or no compensation - 4-pole conductivity measuring cell with integrated temperature-sensor (NTC10kΩ). Electrode material: special graphite, Shaft material: epoxy. Temperature sensor: stainless steel, dimensions: 120 x 12mm L x dia. Items supplied: AL20Con, batteries, 4-Pole conductivity cell, in case Specifications: Conductivity:

Resistance: TDS: Salinity: Accuracy: Temperature: Accuracy: Cell constant: Reference temperature: Nominal temperature: Operating temperature Sensor: Measuring cell: Power consumption: Auto-Off Function:

0.0 to 200.0µS/cm 0 to 2000µS/cm 0.00 to 20.00mS/cm 0.0 to 200.0mS/cm 0.005 to 100.0kΩ/cm 0 to 1999mg/l 0.0 to 70.0g/kg (±0.5% v MW ±0.5% FS ±3 Digits) -5.0 to 100.0°C, meter accuracy ±0.3°C ±0.3K 0.50 ±0.10cm-1 20°C and 25°C 25°C 0 to 50°C -5 to 80°C (up to 100°C for short periods) approx. 3 mA 0 to 120min

Type AL20Con Set

PK

Cat. No.

1

9.699 255

Accessories for Conductivity meter AL20Con AQUALYTIC Type

PK

Cat. No.

Electrode for CD 24, 4-pole Calibration solution 1413µS/cm, 500ml, according to N.I.S.T

1 1

9.699 256 9.699 257

Lanyard Z100 Carrying case, incl. foam insert

1 1

9.699 252 9.699 253

We can supply this

manufactorer’s whole product range ! E & OE.

285


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Oxygen meters 1 Waterproof Oxygen Meter HI9146

1

DO measurements can be displayed in ppm (mg/l) or in % saturation, together with Hanna temperature value. Automatic calibration in the air, at 100%. Automatic temperature compensation from 0 to 50°C. Instrument allows manual compensation of altitude and salinity. Hold-Function allows the user to "freeze" the reading on the LCD. Auto-off after 4 hours of inactivity, input for 12V d.c. adapter. Waterproof Oxygen Meter supplied complete with Oxygen Probe, electrolyte solution for DO probe (30 ml), 2 membranes, 4 batteries and a hard carrying case.

Measuring range/Accuracy: O2 concentration:

0.00 to 45.00 mg/l/ ±1.5 % of Measuring range 0.0 to 300.0 %/ ±1.5 % of Measuring range 0.0 to 50.0°C/±0.5°C

O2 saturation: Temperature: Resolution: O2 concentration: O2 saturation: Temperature: Temperature compensation: Height compensation: Salinity compensation: Environment: Dimensions: Weight:

0.01mg/l 0.1% 0.1°C automatic from 0 to 50°C 0 to 4km/Resolution 0.1km 0 to 80g/Resolution 1g 0 to 50°C 80 x 196 x 60mm 500g

Type

Description

HI 9146-04 HI 9146-10

incl. Oxygen Probe with 4m cable incl. Oxygen Probe with 10m cable

PK

Cat. No.

1 1

9.773 997 9.773 999

2 Portable dissolved oxygen meter Oxi 3205 Robust and easy to use dissolved oxygen meter for standard alkaline, or rechargeable, batteries. Menu-controlled with backlit graphics display for ease of use under all lighting conditions. Suitable for use in harsh environments. Measuring ranges: O2 concentration:

0.00 to 19.99mg/l (19.9mg/l*) 0.0 to 90.0mg/l (90mg/l*) 0.0 to 199.9% (199%*) 0 to 600% -5.0 to +50.0°C * when using DurOx oxygen sensor probes

O2 saturation: Temperature: Accuracy: O2 concentration: O2 saturation:

±0.5% of reading ±0.5% of reading

Type

Description

Oxi Oxi Oxi Oxi

meter only case set including DO sensor CellOx 325 and accessories case set including DO sensor CellOx 325 (3m) and accessories case set including DO sensor DurOx 325 (3m) and accessories

3205 3205 SET 1 3205 SET 2 3205 SET 3

PK 1 1 1 1

2

286

WTW

E & OE.

Cat. No. 9.774 9.774 9.774 9.774

378 340 406 343


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Oxygen meters 1 Portable dissolved oxygen meter Oxi 3210

1

Convenient and versatile dissolved oxygen meter. Menu controlled, with backlit, graphics display. Memory, including GLP supporting functions, temperature compensation, barometric pressure and salinity. Powered by standard alkaline, or rechargeable, batteries.

Measuring ranges: O2 concentration: O2 saturation: Partial pressure: Temperature: Accuracy: O2 concentration: O2 saturation: Partial pressure: Datalogger:

0.00 to 19.99 mg/l (19.9 mg/l*) 0.0 to 90.0 mg/l (90 mg/l*) 0.0 to 199.9% (199%*) 0 to 600% 0.0 to 199.9mbar (199 mbar*) 0 to 1250mbar -5.0 to +50.0°C * when using DurOx oxygen sensor probes ±0.5% of reading ±0.5% of reading ±0.5% of reading 200 records (Reading, Temperature, Date, Time, ID)

Type

Description

Oxi Oxi Oxi Oxi

meter only cased set including DO sensor CellOx 325 and accessories cased set including DO sensor CellOx 325 (3m) and accessories cased set including DO sensor DurOx 325 (3m) and accessories

3210 3210 Set 1 3210 Set 2 3210 Set 3

WTW

PK 1 1 1 1

2 3 DO meter Oxi 3310

Cat. No. 9.774 9.774 9.774 9.774

350 351 407 357

2

Comfortable and versatile DO meter with integral, time controlled, data logger and WTW memory for 5000 GLP compliant records for extended data collection. Menu controlled, with backlit graphics display for comfortable and safe operation. Calibration against external standards possible. Automatic temperature, barometric pressure and salinity compensation. 100% waterproof, USB interface for fast data transfer. Includes driver software and cable. Measuring ranges: O2 concentration: O2 saturation: Temperature: Accuracy: O2 concentration: O2 saturation: Memory:

0.00 to 19.99 mg/l (19.9 mg/l*) 0.0 to 90.0 mg/l (90 mg/l*) 0.0 to 199.9% (199%*) 0 to 600% -5.0 to +50.0°C * when using DurOx oxygen sensor probes ±0.5% of reading ±0.5% of reading 5000 records (measured value, temperature, date, time, ID)

Type

Description

Oxi 3310 Oxi 3310 SET 1 Oxi 3310 SET 2

meter only cased set including DO sensor CellOx 325 and accessories cased set including DO sensor CellOx 325 (3m) and accessories

PK

Cat. No.

1 1 1

9.774 338 9.774 339 9.774 408

3

E & OE.

287


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Oxygen meters 1 Portable/bench dissolved oxygen meters, ProfiLine Oxi 1970i

1

With robust and impact resistant housing. Splashproof (IP66) and submersible (IP67). WTW Cable lengths up to 100 metres are available on request for oxygen measurement at depth. With rechargeable battery giving up to 600 hours of operating time, shoulder strap, hinged carrying handle which also acts as a stand, and electrode case. User friendly, multi-function display, auto test, non-volatile data memory for 50 pairs of readings and RS232 output interface. ProfiLine Oxi 1970i: Unbreakable oxygen meter with rechargeable battery and network operation, data storage, GLP test functions, OxiCal® rapid calibration, automatic air pressure correction by integral barometeric pressure sensor (500 to 1100 hPa), automatic temperature compensation via IMT compensation procedure, automatic salinity correction of 0.0 to 70.0 (adjustable via display), AutoRead for better reproducibility ±0.05 mg/l. Accessories required for oxygen measurement at depth can be obtained upon request.

Measuring range: O2 concentration: O2 saturation: Temperature: Accuracy: O2 concentration: O2 saturation: Temperature:

0.00 to 19.99 mg/l 0.0 to 90.0 mg/l 0.0 to 199.9 % 0 to 600 % -5.0 to +50.0°C ±0.5 % of reading ±0.5 % of reading ±0.1K

Type ProfiLine Oxi 1970i

PK

Cat. No.

1

9.822 592

2 Laboratory dissolved oxygen meters, inoLab®Oxi 730

2

Whether for routine dissolved oxygen measurement in factory processes and quality WTW control, or precise measurement in research and laboratory work, this high accuracy, dissolved oxygen meter offers the highest level of usability, reliability and accuracy for all applications. Variable programme combinations permit routine tasks to be automated. Fully automatic or manual procedures are available for research tasks. inoLab® Oxi 730 Compact, with intuitive operation. Standard dissolved oxygen meter with large multifunctional display for routine laboratory use. Automated functions such as barometric pressure correction, temperature compensation with IMT procedure and OxiCal® rapid calibration enable easy operation. With integral measurement memory, analogue and RS 232 digital outputs and optional built-in printer (paper width 112 mm) guarantee GLP-compliant documentation.

Specifications: Measuring range/Resolution: O2 concentration: O2 saturation: O2 partial pressure: Accuracy (±1 digit): Calibration: Memory:

Type

Description

inoLab Oxi 730 inoLab Oxi 730 Set

with serial interface incl. multifunction box, oxygen probe CellOx 325, accessories as 9.704 182 but additionally with built-in printer for GLP-compliant documentation with built-in printer, incl. multifunction box, self-stirring oxygen probe StirrOx 325, accessories

inoLab Oxi 730

inoLab Oxi 730P Set

288

0.00 to 19.99mg/l 0.0 to 90mg/l 0.0 to 199.9% 0 to 600% 0.0 to 199.9 mbar 0 to 1250 mbar 0.5% of measured value With OxiCal®-SL 800 data records (measured value, temperature, date, time, ID)

E & OE.

PK

Cat. No.

1 1

9.704 182 9.704 215

1

9.704 183

1

9.704 216


GENERAL CATALOGUE 2010/11

3. Analytical measurement and testing Electrochemical meters/Oxygen meters

1 Laboratory dissolved oxygen meters, inoLab Oxi 740 Flexible and powerful. Research level meters with graphics display and digital recorder function for laboratory dissolved oxygen measurement. Automated functions such as barometric pressure correction, temperature compensation with IMT procedure and OxiCal®-rapid calibration enable easy, routine operation. With integral measurement memory, analogue and RS 232 digital outputs and optional built-in printer (paper width 112 mm) guaranteeing GLP-compliant documentation.

WTW

When used in conjunction with StirrOx® G with automatic Start/Stop function inoLab Oxi Level 3 is the ideal meter for routine BOD5 oxygen analysis to DIN 38409 T 51 Specifications: Measuring range/Resolution: O2 concentration: 0.00 to 19.99mg/l 0.0 to 90mg/l O2 saturation: 0.0 to 199.9% 0 to 600% O2 partial pressure 0.0 to 199.9 mbar 0 to 1250 mbar Accuracy (±1 digit): 0.5% of measured value Calibration: With OxiCal®-SL Type

Description

PK

Cat. No.

inoLab Oxi 740 inoLab Oxi 740

with multifunction controller and universal interface As 9.704 184 but additionally with CellOx® 325 oxygen sensor and accessories

1 1

9.704 184 9.704 185

inoLab Oxi 740

With integral printer, multifunction controller and universal interface

1

9.704 186

1

E & OE.

289


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Oxygen meters 1

1 Accessories for Oxygen meters StirrOx G: For inoLab®Oxi 730, ProfiLine 197i/1970i, inoLab®740 Oxi, Self-stirring oxygen sensor. - single-handed use - high reproducibility - ready for immediate use, no polarisation period necessary - extremely low internal consumption of oxygen by the electrode - no zero point calibration necessary - OxiCal®-SL calibration and storage vessel included - 6 months operation with one electrolyte filling - IMT function compensation - membrane leakage monitoring, damaged membranes are indicated. Supplied with case, spare parts and maintenance solutions.

WTW

CellOx 325: For Oxi 3xx, Oxi 3xxi, ProfiLine Oxi 197, ProfiLine Oxi 197i, ProfiLine Multi 197i, Multi 340i, Oxi 3205, Oxi 3210, Oxi 3310, ProfiLine Oxi 1970i, ProfiLIne Multi 1970i inoLab® Membrane-covered, galvanic oxygen sensor. - ready for immediate use, no polarisation period necessary - IMT function compensation - 6 months operation with one electrolyte filling - stable zero point - 1.5 metre cable and waterproof plug (to IP 67) (other cable lengths available on request) - OxiCal®-SL calibration and storage vessel included TriOxmatic® 300: For Oxi 3000 HJ, MultiLab P5 V and MultiLab P4. Membrane-covered, precision oxygen sensor with potentiostatic mode of operation in accordance with the three-pole process. - long-term stability - low internal consumption of oxygen by the electrode - membrane leakage monitoring - automatic monitoring of the remaining electrolyte - short response time - stable zero point - pressure-resistant up to 6 bar - Temperature range 0 to 50°C - IMT function temperature compensation - shaft diameter only 15.5mm, shaft length 160mm - With 1.5 metre cable and OxiCal®-SL calibration and storage vessel . Supplied with case, spare parts and maintenance solutions.

Type StirrOx G CellOx 325 TriOxmatic® 300

2

PK

Cat. No.

1 1 1

9.822 560 9.822 551 9.822 632

2 Oxygen sensor DurOx 325 For use with Oxi 3xxi, ProfiLine Oxi 197i. Membrane-covered oxygen sensor with low flow requirement and removable cage guard, for field applications (fish farm revival pools) and for educational purposes. -

ready to measure - no polarisation time IMT compensation via two integral temperature sensors service life with one electrolyte filling approx. 6 months minimal flow requirement no residual current sensor is watertight (IP 68 - 2) standard with 3 m cable and watertight plug standard with calibration/storage vessel OxiCal® -D standard with cage guard SK-D

Type DurOx 325

290

WTW

E & OE.

PK

Cat. No.

1

9.920 045


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Electrochemical meters/Oxygen meters 1 Dissolved oxygen meter AL20Oxi AQUALYTIC

The new, microprocessor-controlled, AL20 hand-held meter range meets the day-to-day requirement for sturdy and reliable systems for pH or redox, conductivity/TDS, temperature and dissolved oxygen measurement. The water-tight housing complies with IP67 and is fitted with protective armouring to ensure reliable operation even in extreme ambient conditions. The support can be flipped up to hang the meter on pipes or branches. -

battery operation period up to 15.000 hours (4 x 1.5V Type AA batteries) auto Hold function internal memory for 20 data sets self-polarising oxygen electrode with integral NTC sensor

Specifications: O2 partial pressure: O2 concentration: O2 saturation: Accuracy: Temperature: Accuracy: Abs. air pressure: Accuracy: Nominal temperature: Operating temperature: Storage temperature: Power consumption: Auto-Off Function:

0.0 to 570.0hPa, 0.0 to 427.4mmHg, or 0 to 1200hPa, 0 to 900mmHg 0.00 to 25.00mg/l or 0.0 to 70.0mg/l 0.0 to 250.0% or 0 to 600% ±1.5 ±0.2 mg/l (0 to 25 mg/l) or ±2.5 ±0.3 mg/l (25 to 70 mg/l) ±1 digit -5.0 to +50.0°C 23.0 to 122.0°F ±0.1°C 500 to 1100hPa ±0.5% fsd 25°C 0 to 50°C -20 to 70°C max. 0.25mA 0 to 120min

Type

Description

AL20Oxi Set

complete in carrying case

PK

Cat. No.

1

9.699 245

Accessories for Dissolved-Oxygen-Meter AL20Oxi Type

PK

Cat. No.

Oxygen electrode, 1m cable Oxygen electrode, 10m cable Oxygen electrode, 30m cable Service Set for Oxygen electrode with 3 Membrane Heads, 100ml KOH solution

1 1 1 1

9.699 9.699 9.699 9.699

248 249 250 251

Lanyard Z100 Carrying case, incl. foam insert

1 1

9.699 252 9.699 253

1

E & OE.

291


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Balances/Pocket balances 1

1 Pocket electronic balances, CM series This wallet-sized balance is well protected by it's hinged cover against all kinds of Kern & Sohn impacts, pressure and dust and fits neatly into a jacket pocket. With integrated 'Weigh-in' function for mixture preparation and 'Cal' adjustment programme for precise calibration. Supplied with batteries. Dimensions (WxDxH): 85 x 130 x 25mm Weight: 175g Type

CM CM CM CM

2

60-2N 150-1N 320-1N 1K1N

Readability

Capacity

g 0.01 0.1 0.1 1.0

g 60 150 320 1000

Pan dim. mm 80 x 70 80 x 70 80 x 70 80 x 70

PK

1 1 1 1

9.901 9.901 9.901 9.901

366 364 365 362

2 Pocket Balances Simple, compact and handy. WxDxH: 13.6 x 8.3 x 2.0cm. Ideal for precise weighing in the field. - automatic calibration, using external weight. - large, high-contrast, liquid crystal display with back light. - robust plastic housing. - auto-off function prolongs battery life. - includes protective cover and batteries.

Type

JE120 JE250 JE500

3

Cat. No.

Readability Weighing range g g 0.1 120 0.1 250 0.1 500

Pan dim. mm 83 x 76 83 x 76 83 x 76

Ohaus

PK

Cat. No.

1 1 1

9.902 413 9.902 414 9.902 415

3 Portable electronic balances, CS series -

Compact and practical with choice of weighing ranges from 200g to 5000g Sleek, low-profile housing Stainless steel weighing pan Large, 11mm high digital display Energy-saving, automatic switch-off Robust plastic construction Battery or mains operation

Ohaus

Supplied with 3 x 1.5V AAA batteries and mains adapter. Dimensions WxDxH: 135 x 193 x 39mm Accessories: 1050ml plastic container Type

CS200 CS2000 CS5000

Readability Weighing range g g 0.1 200 1.0 2000 1.0 5000

Weighing pan mm 146 x 133 146 x 133 146 x 133

PK

Cat. No.

1 1 1

9.950 222 9.950 223 9.950 224

Accessories for Portable electronic balances, CS series Ohaus Description Plastic container, 1050ml Mains adapter Stainless steel weighing pan cover

292

E & OE.

PK

Cat. No.

1 1 1

9.947 300 9.947 301 9.947 302


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Balances/Pocket balances 1 2 Portable Balances, Scout Pro series

1

The Scout Pro offers simple operation and higher resolution to accommodate more Ohaus applications than ever before: - high contrast, LCD display. - parts counting, percentage weighing, check weighing, totalisation, weigh-below facility, display-hold-function - simple, two-button operation - density determination kit for automatic specific gravity calculations (optional accessory) - optional USB or RS232 interface accessories (cable included) - battery or a.c. operation (a.c. adapter included) - 1 mg readability model supplied with draught shield - programmable, energy saving, auto switch-off - below-balance weighing (weighing hook included)

Type

SPU123 SPU202 SPU402 SPU401 SPU602 SPU601 SPU2001 SPU4001 SPU6000 SPU6001

Readability Weighing range g g 0.001 120 0.01 200 0.01 400 0.1 400 0,01 600 0.1 600 0.1 2000 0.1 4000 1 6000 0,1 6000

Pan dim. mm 90 dia. 120 dia. 120 dia. 120 dia. 120 dia. 165 x 142 165 x 142 165 x 142 165 x 142 165 x 142

PK

1 1 1 1 1 1 1 1 1 1

2

Cat. No.

9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902

420 421 422 423 428 424 425 426 427 429

3 Electronic letter scale

3

Electronic letter and small packet scale with practical one-key operation. Scale features lift-up platform to weight large size envelopes without obscuring the display. Powered by batteries (supplied) or mains adapter. Automatic switch-off after approx. 1 min of non-use in battery mode to maximise battery lifetime.

Balance: Weighing pan: Weight:

205 x 170 x 42mm 160 x 153mm. 910g

Type WEDO 2000 Mains adapter

PK

Cat. No.

1 1

9.017 900 9.017 910

4 Compact balances Type EMB

4

Economically priced, battery-operated models. Large LCD readout with 16mm high Kern & Sohn digits. "Weigh-in" function simplifies mixing. Supplied with 4 x 1.5V AA batteries. With d.c. power connection socket (accessory mains adapter available at extra cost). Auto-off function activates after 3 minutes without use for saving battery power. Dimensions WxDxH: Net weight: Type

EMB EMB EMB EMB EMB EMB EMB EMB

200-2 600-2 220-1 500-1 1200-1 2200-0 5.2K1 5.2 K 5

170 x 240 x 38mm approx. 600g

Readability

Capacity

PK

g 0.01 0.01 0.1 0.1 0.1 1.0 1.0 5.0

g 200 600 220 500 1200 2200 5200 5200

1 1 1 1 1 1 1 1

E & OE.

Cat. No.

9.901 9.901 9.901 9.901 9.901 9.901 9.901 9.901

320 321 370 322 323 371 324 372

293


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Balances/Pocket balances 1 2 3 Balances, electronic, compact, 440 series

1

With features including formulation, piece counting programmes and high accuracy Kern & Sohn these balances are ideal for routine laboratory tasks. Calibration adjustment programme maintains accuracy. Can be battery operated (9V PP3, not supplied). With stainless steel balance platform as indicated. Supplied with working cover and mains adapter requiring a 230V 50/60Hz supply.

Overall (WxDxH): Weight: Type

9.901 348

440-21N 440-21A 440-33N 440-35N 440-35A 440-43N 440-45N 440-47N 440-49N 440-49A 440-51N 440-53N

165 x 230 x 80 mm approx. 1 kg

Readability

Capacity

g 0.001 0.001 0.01 0.01 0.01 0.1 0.1 0.1 0.1 0.1 1 1

g 40 60 200 400 600 400 1000 2000 4000 6000 4000 6000

Reproducibility Âąg 0.001 0.001 0.01 0.01 0.01 0.1 0.1 0.1 0.1 0.1 1 1

Pan dim. mm 81 dia. 81 dia. 105 dia. 105 dia. 105 dia. 130 x 130 130 x 130 130 x 130 170 x 150 170 x 150 170 x 150 170 x 150

2

9.901 9.901 9.901 9.901 9.901 9.901 9.901 9.901 9.901 9.901 9.901 9.901

338 340 348 349 341 344 346 347 343 342 345 350

9.901 343

4 Compact Balances EK-i series -

EK-610i and EK-6100i can be verified compact, low profile design multiple Weighing Units: g,%, pcs, oz, ozt, tl, lb, GN, dwt, ct, mo large, backlit, wide-angle LCD readout control zero, mode selection and data output with RS232C port triple range weighing for EW-i series conformity to GLP with I.D. and serial number output auto power off sealed key panel protection against dust and spills full digital calibration standard comparator function-Hi/OK/LO annunciator ACAI counting function for highly accurate counting overload protection security ring secures balance to bench to protect against theft WinCT data software CD-ROM included

Type

EK-410i EK-610i-EC EK-4100i EK-6100i-EC EK-12Ki

294

1 1 1 1 1 1 1 1 1 1 1 1

Cat. No.

3

9.901 346

4

PK

Readability

Capacity

g 0.01 0.01 0.01 0.1 1.00

g 400 600 4000 6000 12000

E & OE.

Pan dim. mm 110 dia. 110 dia. 133 x 170 133 x 170 133 x 170

A&D Inst.

PK

1 1 1 1 1

Cat. No.

9.901 9.901 9.901 9.901 9.901

511 512 515 516 517


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Balances/Pocket balances-Precision balances 1 Compact Balances HL-i series -

1

High weighing resolution of 1/2000 Large LCD readout Calibration function Tare function Auto Power OFF function Multiple weighing units Batteries included

Type

HL-200i HL-2000i

Readability

Capacity

g 0.1 1.0

g 200 2000

A&D Inst.

Pan dia. mm 130 130

PK

Cat. No.

1 1

9.901 521 9.901 523

2 Balances, electronic, precision, 572 series

2

Weighing speed adjustable in two stages. Unit transfer to bullion and non-metric units Kern & Sohn of weight. With calibration adjustment programme. With net/total weighing. Piece counting: 1, 5, 10 or 20 reference pieces. Percentage weighing. Bi-directional RS232C data output supplied. Ultra lowprofile, metal casing (WxDxH): 150 x 310 x 60mm. Supplied with mains adapter for 230V 50/60Hz. Balances can be alternatively operated by accessory batteries. Also available with DKD certified calibration weight, thermal printer, statistic printer, rechargeable battery pack or label printer at additional cost.

Type

572-31* 572-32* 572-33 572-35 572-37 572-45 572-49 572-57

Readability

Capacity

g 0.001 0.001 0.01 0.01 0.01 0.1 0.1 0.1

g 241 301 1610 2410 3010 12100 16100 24100

Reproducibility Âąg 0.001 0.001 0.01 0.01 0,01 0.1 0.1 0.1

Pan dim. mm 105 dia. 105 dia. 150 dia. 150 dia. 160 x 200 160 x 200 160 x 200 160 x 200

PK

1 1 1 1 1 1 1 1

Cat. No.

9.900 6.229 9.901 9.901 6.227 9.900 9.901 9.901

990 315 333 335 789 991 336 354

*with removable draught shield

We can supply this

manufactorer’s whole product range ! E & OE.

295


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Balances/Precision balances 1

2

9.901 403

9.901 410

1 2 3 Precision balance KB

3

Convenience model at an economical price

9.901 401

- for applications that require verification, please order verification at the same time, verification at a later date is not possible. - user guidance step by step in the display - freely programmable weighing units, e.g. display directly in special units such as the length of thread g/m, paper weight g/m², or similar - precise counting. The automatic reference optimization gradually improves the average value of the piece weighing - numerical tare deduction for container weighing. Useful when checking loads - ring-shaped draft shield standard, 90 x 40mm dia. x ht. for models with readability d = 0.001g also available with DKD certified calibration weight, thermal printer, statistics printer, or label printer at additional cost.

Type

KB KB KB KB KB KB KB KB KB KB KB KB KB KB

296

Kern & Sohn

120-3N 200-3N 240-3N 360-3N 1200-2N 2000-2N 2400-2N 3600-2N 10K0.05N 10000-1N 650-2NM 2000-2NM 6500-1NM 10000-1NM

Readability

Capacity

g 0.001 0.001 0.001 0.001 0.01 0.01 0.01 0.01 0.05 0.1 0.01 0.01 0.1 0.1

g 121 201 241 361 1210 2010 2410 3610 10100 10100 650 2000 6500 10000

E & OE.

Reproducibility ±g 0.001 0.001 0.001 0.001 0.01 0.01 0.01 0.01 0.05 0.1 0.01 0.01 0.1 0.1

Linearity

PK

±g 0.003 0.003 0.003 0.003 0.03 0.03 0.03 0.03 0.15 0.3 0.03 0.03 0.3 0.3

1 1 1 1 1 1 1 1 1 1 1 1 1 1

Cat. No.

6.234 9.901 6.235 9.901 6.233 6.231 9.901 9.901 9.901 9.901 9.901 9.901 9.901 9.901

511 401 214 402 613 607 403 404 405 406 407 408 409 410


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Balances/Precision balances 1 2 Precision balance PLE Low-cost precision balance with wide range of functions

Kern & Sohn

- weighing sum memory adds single weighing results - weighing with tolerance range (Checkweighing) - percentage determination: makes it possible to store a given weight value (100%) and to determine deviations from this target value. - ring-shaped, glass draught shield as standard on all models with readability d = 0.001g]. Removable metal cover with pipette opening. Weighing space 150 x 50mm dia. x ht. - integral rechargeable battery pack. Operating time approx. 35 hours, charging time approx. 10 hours. Also available with DKD certified calibration weight, thermal printer, statistics printer, or label printer at additional cost.

1

2

Type

PLE PLE PLE PLE

310-3N 3100-2N 610-3NM 6100-1NM

Readability

Capacity

g 0.001 0.01 0.001 0.01

g 310 3100 610 6100

Reproducibility ±g 0.001 0.01 0.001 0.01

Pan dia. mm 80 135 80 135

Linearity

PK

±g 0.002 0.02 0.002 0.02

1 1 1 1

3 Precision balances type EW-N, EG-N

Cat. No.

9.901 9.901 9.901 9.901

325 326 327 328

3

High quality laboratory balances, housed in a robust and stable metal casing. With bar Kern & Sohn graph capacity display which shows the current available weighing range remaining. Fitted with protective working cover for casing and keyboard. Suitable for EC verification (factory option at additional cost - details on request). Convenient, internal automatic calibration (only type EG-N) as well as extensive configuration and application menus. Glass draught shield supplied with all 0.001g readability models. Additionally supplied with parts counting facility, percentage weighing function, flush-mounted platform, dust and liquid, splash protection. Dimensions WxDxH: 190 x 265 x 90mm.

Type

EW220-3NM EW420-3NM EW620-3NM EW820-2NM EW2200-2NM* EW4200-2NM* EW6200-2NM* EW12000-1NM* EG220-3NM EG420-3NM EG620-3NM EG2200-2NM* EG4200-2NM*

Readability

Capacity

g 0.001 0.001 0.001 0.01 0.01 0.01 0.01 0.1 0.001 0.001 0.001 0.01 0.01

g 220 420 620 820 2200 4200 6200 12000 220 420 620 2200 4200

Reproducibility ±g 0.001 0.001 0.001 0.01 0.01 0.01 0.01 0.1 0.001 0.001 0.001 0.01 0.01

Pan dim. mm 118 dia. 118 dia. 118 dia. 170 x 142 180 x 160* 180 x 160* 180 x 160* 180 x 160* 118 dia. 118 dia. 118 dia. 180 x 160* 180 x 160*

PK

1 1 1 1 1 1 1 1 1 1 1 1 1

Cat. No.

9.901 9.901 9.901 9.901 9.901 9.901 9.901 9.901 9.901 9.901 9.901 9.901 9.901

007 008 009 010 011 012 013 014 018 019 015 016 017

* Overall dimensions WxDxH (without glass draught shield): 182 x 235 x 75mm

E & OE.

297


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Balances/Precision balances 1 2 Precision balance Type PLS/PLJ - ergonomically optimised keypad for left and right-handed users Kern & Sohn - ring-shaped glass draught shield standard for all models with 0.001g resolution. Removable metal cover with pipette opening. Weighing space 150mm dia., height 60mm - count/weight switchover at the press of a button - precise counting. The automatic optimisation of reference weight gradually improves the average value of the piece weight. The automatic optimisation of reference weight gradually improves the average value of the piece weight - weighing with tolerance range Input of an upper/lower limit value. A visual signal assists with portion division, dispensing or grading - percentage determination makes it possible to store a given weight value (100%) and to determine deviations from this target value in % - density determination of liquids and solids with immediate display of the density on the display - pre-Tare function for manual deduction of a known container weight. Useful for checking fill-levels - model PLJ only: automatic internal calibration which can be time-controlled, or activated when there is a change in temperature >1.5°C

1

Type

PLS 310-3F PLS 510-3A PLS 720-3A PLS 1200-3A PLS 1200-3DA PLS 3100-2F PLS 4200-2A PLS 6200-2A PLS 6200-2DA PLJ 510-3AM

Readability Weighing range g g 0.001 310 0.001 510 0.001 720 0.001 1200 0.001/0.01 720/1200 0.01 3100 0.01 4200 0.01 6200 0.01/0.1 4200/6200 0.001 510

2

Reproducibility ±g 0.002 0.001 0.001 0.001 0.001/0.01 0.01 0.01 0.01 0.01/0.1 0.1

Linearity

PK

±g 0.003 0.002 0.002 0.002 0.002/0.02 0.03 0.02 0.02 0.02/0.2 0.002

1 1 1 1 1 1 1 1 1 1

Cat. No.

9.901 9.901 9.901 9.901 9.901 9.901 9.901 9.901 9.901 9.901

411 412 413 414 415 416 417 418 419 420

3 Precision balance, AdventurerTM Pro series

3

Ideal for standard weighing tasks in laboratory, industrial and educational routines. Ohaus - easy to use and with a robust housing. - simple 4-button-operation - backlit, twin-line display with text guidance and weight displays - parts counting, percentage weighing, below-balance weighing, totalisation, animal weighing, checkweighing facilities, gross/net/tare-function, - display-hold function - GLP/GMP protocol with date/time - RS232 interface - protective working cover for the display - electronic filter - full glass draught shield for the 1 mg model - battery or mains supply with automatic switch-off. - also available as approved model.

Type

AV212 AV412 AV812 AV2101 AV4101 AV8101

298

Readability Weighing range g g 0.01 210 0.01 410 0.01 810 0.1 2100 0.1 4100 0.1 8100

Pan dim. mm 120 dia. 149 x 162 149 x 162 149 x 162 149 x 162 149 x 162

Description

external external external external external external

PK

calibration calibration calibration calibration calibration calibration

1 1 1 1 1 1

E & OE.

Cat. No.

9.947 9.947 9.947 9.947 9.947 9.947

651 652 653 654 655 656


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Balances/Precision balances 1 2 Precision balances, Explorer® Pro series

1

The Explorer® Pro provides 7 application programmes, a high-contrast graphics display and a menu navigation in 5 selectable languages. Modern weighing technology satisfies the demanding requirements of the analytical laboratory. - large, backlit and high-contrast, graphics display - easy, menu-driven operation with cursor keys - weighing, parts counting, animal weighing, percentage weighing, check weighing, net/ total formulation - GLP-protocol with date and time - an additional interface for connecting a secondary display or indicator - optional AutoCal™ for optimized weighing performance - ergonomic levelling system - weigh-below facility - menu navigation in 5 selectable languages - digital vibration filter levels enable the balances to optimally adapt to environmental conditions. - keyboard/display protective working cover supplied - bi-directional RS232 interface - type-approved versions also available

Type

EP213 EP413 EP613 EP413D EP612 EP2102 EP4102 EP4102D EP6102 EP4101 EP6101 EP8101 EP213C** EP413C** EP613C** EP413DC** EP612C** EP2102C** EP4102C** EP4102DC** EP6102C** EP4101C** EP6101C** EP8101C**

Readability Weighing range g g 0.001 210 0.001 410 0.001 610 0.001*/0.01 100*/410 0.01 610 0.01 2100 0.01 4100 0.01*/0.1 1000*/4100 0.01 6100 0.1 4100 0.1 6100 0.1 8100 0.001 210 0.001 410 0.001 610 0.001*/0.01 100*/410 0.01 610 0.01 2100 0.01 4100 0.01*/0.1 1000*/4100 0.01 6100 0.1 4100 0.1 6100 0.1 8100

Pan dim. mm 121 dia. 121 dia. 121 dia. 121 dia. 173 x 173 173 x 173 173 x 173 173 x 173 173 x 173 203 x 203 203 x 203 203 x 203 121 dia. 121 dia. 121 dia. 121 dia. 173 x 173 173 x 173 173 x 173 173 x 173 173 x 173 173 x 173 173 x 173 173 x 173

Description

Ohaus

PK

external calibration external calibration external calibration external calibration external calibration external calibration external calibration external calibration external calibration external calibration external calibration external calibration internal calibration internal calibration internal calibration internal calibration internal calibration internal calibration internal calibration internal calibration internal calibration internal calibration internal calibration internal calibration

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Cat. No.

9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902

174 175 176 177 178 179 180 181 185 182 183 184 390 391 392 393 394 395 396 397 398 399 400 401

* moveable fine range **Type-approved models available on request

2

E & OE.

299


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Balances/Precision balances 1 Precision balance ExplorerÂŽ Pro Giant

1

Applications made easy. High precision and robust design are key features of these Ohaus balances. - large, back-lit graphics LCD readout - cursor selection keys and menu navigation in 5 languages for ease-of-use - weighing, parts counting, animal weighing, percent weighing, filling, dynamic weighing, check weighing, density - statistics function and application library - GLP-protocol with date and time - optional AutoCal™ for optimized weighing performance - below-balance weighing - ergonomic levelling system with front level bubble - user selectable filter, stability indicator and auto-zero tracking settings to compensate for vibration - protective in-use cover - bi-directional, RS232 interface - type-approved versions also available.

Type

EP12001 EP22001 EP32001 EP12001C EP22001C EP32001C EP12001CM EP22001CM EP32001CM

Readability Weighing range g g 0.1 12000 0.1 22000 0.1 32000 0.1 12000 0.1 22000 0.1 32000 0.1 12000 0.1 22000 0.1 32000

Description

ext. calibration ext. calibration ext. calibration int. calibration int. calibration int. calibration int. calibration * int. calibration * int. calibration *

280 280 280 280 280 280 280 280 280

Pan dim. mm x 360 x 360 x 360 x 360 x 360 x 360 x 360 x 360 x 360

PK

1 1 1 1 1 1 1 1 1

Cat. No.

9.947 9.947 9.947 9.947 9.947 9.947 9.947 9.947 9.947

630 631 632 633 634 635 636 637 638

* calibrated ex works

2 3 Precision Balances FX-i series -

compact B5 size fast stabilization speed (1 second) multiple weighing units standard RS-232C interface USB interface (driver installation not necessary) Ethernet interface with WinCT-Plus software GLP, GMP, GCP, ISO compliant statistical calculation function comparator function large, bright, vacuum fluorescent display built-in rechargeable battery weigh-below hook for suspended weighing standard draught shield for 1mg resolution models counting function with ACAI ( Automatic Counting Accuracy Improvement) auto power ON/OFF function digital calibration function

Type

Readability

Capacity

g 0.001 0.01

g 320 3200

FX-300i* FX-3000i

A&D Inst.

Pan dia. mm 130 150

*Supplied with Glass draught shield

2

300

3

E & OE.

PK

Cat. No.

1 1

9.901 501 9.901 503


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Balances/Precision balances-Analytical balances 1 Precision Balances Pioneer™ -

1

weighing (18 units + 1 custom unit), parts counting, percentage weighing Ohaus LCD readout mains power RS232 for sending balance ID and weight solid, diecast, metal housing, stainless steel pan fixed, integral, weigh-below hook, all-glass draught shield with 3 sliding doors, front levelling bubble, menu and calibration locks

Type

PA213 PA213C PA213CM PA413 PA413C PA413CM PA512 PA512C PA512CM PA2102 PA2102C PA2102CM PA4102 PA4102C PA4102CM PA4101 PA4101C PA4101CM

Readability

Capacity

1mg 1mg 1mg 1mg 1mg 1mg 0.01g 0.01g 0.01g 0.01g 0.01g 0.01g 0.01g 0.01g 0.01g 0.1g 0.1g 0.1g

g 210 210 210 410 410 410 510 510 510 2100 2100 2100 4100 4100 4100 4100 4100 4100

Pan dia. mm 120 120 120 120 120 120 180 180 180 180 180 180 180 180 180 180 180 180

Description

PK

external calibration internal calibration internal calibration external calibration internal calibration internal calibration external calibration internal calibration internal calibration external calibration internal calibration internal calibration external calibration internal calibration internal calibration external calibration internal calibration internal calibration

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

2 Semi-micro/Analytical Balance -

GR-200

Readability

Capacity

g 0.1

g 210

9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902 6.234 9.902 9.902 9.902 9.902 9.902 9.902 9.902

130 131 132 133 134 135 136 137 138 139 850 141 142 143 144 145 146 147

2

One-touch, fully automatic, autocalibration Easy access door Splashproof keyboard and display Advanced stabilization software Automatic, adjustable environmental filter setting Multiple weighing units GLP compliant Standard RS-232C communication Below-balance weighing hook supplied WinCT data software CD-ROM included

Type

Cat. No.

A&D Inst.

Pan dia. mm 85

E & OE.

PK

Cat. No.

1

9.901 531

301


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Balances/Analytical balances 1

1 Balances, electronic, analytical, ABS and ABJ series High performance, low cost analytical balances with a robust and stable metal housing Kern & Sohn and bar graph capacity display which shows the current available weighing range remaining. User-programmable, 4-figure balance ID number, LCD readout with 14mm high digits and 80mm diameter weighing pan. For 230V 50/60 Hz supplies. Also available with DKD certified, calibration weight, ionizer, thermal printer, statistic printer, rechargeable battery pack or label printer at additional cost. Analytical balance ABJ: Generally as type ABS, but additionally features automatic internal calibration and g to ct conversion function.

Housing WxDxH: Weighing chamber: Net weight:

2

Type

Readability

ABS 80-4 ABS 120-4 ABS 220-4 ABJ 80-4M ABJ 120-4M ABJ 220-4M ABJ 320-4

mg 0,1 0.1 0.1 0.1 0.1 0.1 0,1

225 x 315 x 330mm 190 x 155 x 200mm approx. 7kg Capacity Reproducibility g 83 120 220 83 120 220 320

± mg 0,1 0.1 0.1 0.1 0.1 0.1 0,1

Pan dia. mm 80 80 80 80 80 80 80

PK

1 1 1 1 1 1 1

Cat. No.

9.901 9.901 9.901 9.901 9.901 9.901 9.901

389 385 386 390 391 392 421

2 Balances, electronic, analytical, AES/AEJ series High performance, low cost analytical balances with compact housing, bar graph Kern & Sohn capacity display which shows the current available weighing range and user-programmable LCD readout with 17mm high digits. Also incorporates automatic internal calibration. For 230V 50/60 Hz supplies. Available with DKD certified calibration weight at additional cost. external calibration available. Languages: D, UK, FR, ES, IT, PL.

3

Type

Readability

AES 120-4 AES 220-4 AEJ 120-4M AEJ 220-4M

mg 0.1 0.1 0.1 0.1

Weighing range g 120 220 120 220

Reproducibility ± mg 0.1 0.1 0.1 0.1

PK

1 1 1 1

Cat. No.

9.900 9.900 9.900 9.900

950 951 952 953

3 Balances, electronic, analytical, ABT series Analytical and semi-microbalances which are suitable for verification. Kern & Sohn All models have automatic calibration adjustment function by internal, motor-driven, calibration weight. It is possible to log ISO/GLP-compliant weighing or calibration data at any time via an accessory printer (not supplied) or data interface (bi-directional RS232-C). Additionally, the balances have formulation, piece counting and percentage determination functions, as well as a flush-mounted weighing platform. All models are supplied with a modern, all-glass draught shield with sliding doors to the left, right and top. Also available with DKD certified, calibration weight, ionizer, thermal printer, statistic printer, recchargeable battery pack or label printer at additional cost.

Weighing pan, stainless steel: Weighing chamber (WxDxH): Dimensions (WxDxH): Mains adapter: Type

ABT ABT ABT ABT ABT

302

120-4 220-4 320-4 120-5 220-5

Readability

M M M DM DM

mg 0.1 0.1 0.1 0.01 / 0.1 0.01 / 0.1

80mm dia. 168 x 172 x 223mm 217 x 356 x 338mm 220V

Weighing range g 120 220 320 42 / 120 82 / 220

Reproducibility ± mg 0.1 0.1 0.1 0.02 / 0.1 0.05 / 0.1

E & OE.

PK

1 1 1 1 1

Cat. No.

9.900 9.900 9.900 9.900 9.900

955 956 957 958 959


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Balances/Analytical balances 1 Analytical balance Pioneer™

1

-

weighing (18 units + 1 custom unit), parts counting, percentage weighing Ohaus LCD readout mains power RS232 for outputting balance ID and weight solid, diecast, metal housing, stainless steel pan fixed, integral, weigh-below hook, all-glass draught shield with 3 sliding doors, front levelling bubble, menu and calibration locks - type-approved versions also available

Type

Readability

PA64 PA64C PA64CM PA114 PA114C PA114CM PA214 PA214C PA214CM

mg 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1

Weighing range g 65 65 65 110 110 110 210 210 210

Pan dia. mm 90 90 90 90 90 90 90 90 90

PK

1 1 1 1 1 1 1 1 1

Cat. No.

6.234 9.902 9.902 6.233 9.902 9.902 9.902 6.233 9.902

827 151 152 682 154 155 156 795 158

2 Analytical balances Explorer Pro series

2

The Explorer Pro provides 7 application programmes, a high-contrast graphics display and a menu navigation in 5 selectable languages. Modern weighing technology satisfies the demanding requirements of the analytical laboratory. - large, backlit and high-contrast, graphics display - easy, menu-driven operation with cursor keys - weighing, parts counting, animal weighing, percentage weighing, check weighing, net/ total formulation - GLP-protocol with date and time - an additional interface for connecting a secondary display or indicator - optional AutoCal™ for optimized weighing performance - ergonomic levelling system - weigh-below facility - menu navigation in 5 selectable languages - digital vibration filter levels enable the balances to optimally adapt to environmental conditions. - keyboard/display protective working cover supplied - bi-directional RS232 interface - type-approved versions also available

Type

Description

Readability

EP64 EP114 EP214 EP214D EP64C EP114C EP214C EP214DC

ext. calibration ext. calibration ext. calibration ext. calibration int. calibration int. calibration int. calibration int. calibration

mg 0.1 0.1 0.1 0.1*/1 0.1 0.1 0.1 0.1*/1

Weighing range g 62 110 210 100*/210 62 110 210 100*/210

Pan dia. mm 90 90 90 90 90 90 90 90

Ohaus

PK

1 1 1 1 1 1 1 1

Cat. No.

9.902 9.902 9.902 9.902 9.902 9.902 9.902 9.902

170 171 172 173 190 191 192 193

* movable fine range

E & OE.

303


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Balances/Analytical balances-Moisture balances 1 Analytical balances, Discovery

1

Premium performance and precision. Ohaus With internal, motorised calibration, GLP-software and 11 essential analytical software applications, each Analytical Plus balance provides a perfect combination of user-friendly operation and supreme performance. - GLP-software - statistics for up to 255 samples - density and volume determination - internal autocalibration with two internal weights - digital temperature compensation - menu and calibration assurance - analogue weighing range indication - bi-directional RS232 interface - type-approved versions also available.

Type

Readability

DV114C DV 114CM** DV214C DV 214CM** DV 314C DV 314CM** DV 215CD* DV 215CDM* **

mg 0.1 0.1 0.1 0.1 0.1 0.1 0.01/0.1 0.01/0.1

Weighing range g 110 110 210 210 310 310 81/210 81/210

Pan dia. mm 90 90 90 90 90 90 90 90

PK

1 1 1 1 1 1 1 1

Cat. No.

9.902 9.902 6.232 6.233 9.902 9.902 6.229 6.227

160 161 314 833 164 165 783 197

* Autoranging **calibrated ex factory

2 3 Moisture balances MB-23 and MB-25

2

The Ohaus MB Series Moisture Analyzers MB-23 and MB-25 provide stable results with 0.1% or 0.05% moisture resolution because of precision weighing technology. They are supplied with either an infra-red, or halogen, heating system. Applicable for most applications. Graphical interface control. No programming necessary. -

Ohaus

halogen (MB-25) or infra-red (MB23) technology 110g capacity operating temperature 50^C to 160°C, set in 5°C displayed data: 0.005g/0.05% (MB25) and 0.001g/0.1% (MB23) sample holder included in MB25 but as option in MB23 delivered with 50 x 90mm aluminium sample dishes and dust cover

3

Specifications Capacity (g): Electricity supply: Dimensions (WxHxD): Net weight (kg): Type

Heating

MB23 MB25

Infra-red heating (no glass) Halogen heating

304

110 100 to 240V 50/60 Hz a.c. 17 x 13 x 28cm 2.3 Reproducibility ±g 0.2% (10g sample) 0.05% (10g sample)

E & OE.

Readability mg 10 5

PK

Cat. No.

1 1

9.947 604 9.947 605


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Balances/Moisture balances 1 Halogen moisture balance MB-35

1

The basic model MB35 offers fast, halogen heating and powerful software for simple operation. Temperature range: 50° to 160°C. Standard tasks can be achieved quickly, simply and with absolute reliability. Also, with its robust and stable housing, the MB-35 provides accurate and repeatable results where quality has to ensured, even in difficult conditions. - Halogen-technology (up to 40% faster than infra-red) - 35 g capacity with 0.01%/0.001 g readability - Reproducibility 0.10% - 0.03% - Temperature range: 50° to 160°C ( 5°C increments) - Backlit graphics display - 3 selectable automatic shut-off modes - Menu-driven in 5 selectable languages - RS232 Interface - Compact and robust housing.

Type

MB 35

Readability Weighing range g g 0.01% / 0.001 35

Pan dia. mm 90

Ohaus

PK

Cat. No.

1

9.947 500

2 Moisture balance MB-45 -

2

Halogen heating technology Menu navigation in 5 selectable languages Four, user defined, temperature profiles Large, back-lit graphics LCD readout Six selectable automatic shut-off modes Fifty, user-defined, drying programmes RS232 data interface

Specifications Weighing range: Readability: Temperature range: Timer: Measurement display: Shut-off modes: Temperature profile: Memory: Weight calibration: Dryer calibration.: Dimensions WxDxH: Weight: Accessories, optional:

Ohaus

45 g 0.01%/0.001 g 50 to 200°C (1°C stages) 1.0 to 120 mins. (0.1 min. increments) % moisture, % dry substance, % ratio, gram or user defined Manual, time-controlled, Auto30, Auto60, Auto90, automatic can be freely selected Standard, rapid, gentle, gradual 50 named drying procedures 20g external calibration weight, optional 100°C and 160°C with optional temperature calibration set 190 x 350 x 150mm 4.6kg Disposable sample dishes, reusable sample dishes, glass fibre filters, theft protection, protection cap, temperature calibration set, calibration weight, printer

Type MB-45

PK

Cat. No.

1

9.950 065

Moisture balance MB-45, accessories Ohaus Description

PK

Calibration weight 20g Protective cover Temperature calibration set Theft protection clamp

1 2 1 1

E & OE.

Cat. No. 9.947 9.947 9.947 9.947

309 313 314 316

305


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Balances/Moisture balances 1 Halogen Moisture Analyser MLB 50-3N

1

-

2 Halogen quartz glass heaters, each 200W 10 sample dishes included 3 displays for temperature, drying in %, drying time Application table. Various examples in the user manual CAL adjustment programme. External calibration weights are available at additional cost The last value measured remains on the display until it is replaced by a new measurement

Specifications Readability d: Weighing range, max: Reproducibility: Linearity: Temperature range:

Kern & Sohn

0.001 g 50 g 0.001 g ±0.003 g 50 to 160°C

Type MLB 50-3

PK

Cat. No.

1

9.901 400

2 3 Halogen moisture analyzers MS-70/MX-50/MF-50/ML-50

2

-

fast and uniform heating with a straight halogen lamp A&D Inst. high reproducibility due to SHS (Super Hybrid Sensor) technology innovative SRA (Secondary Radiation Assist) technology shorten measurement time standard WinCT-Moisture (for MS-70/MX-50 only) Sodium Tartrate Dehydrate with its stable moisture rate comes as standard for accuracy checking optional temperature calibrator, calibration result can be output memory function four choices of measurement programmes, Standard, Automatic Complete, Timer, and Manual Mode are selectable selectable heating modes; standard, quick, step and ramp heating clear and easy-to-read, large, vacuum fluorescent display integral RS232C conformity to GLP,GMP,GCP and ISO with date/time ID calibration data and check record outputs

3

Specifications Max. weight sample MS-70: MX-50/MF-50/ML-50: Drying temperature MS-70: MX-50/MF-50/ML-50: Pan size: Type

Resolution Weight

Resolution Value

MS-70 MX-50 MF-50 ML-50

0.0001 g 0.001 g 0.002 g 0.005 g

0.001% / 0.01% / 0.1% 0.01% / 0.1% 0.05% / 0.1% / 1% 0.1% / 1%

306

71g 51g 30 to 200°C 50 to 200°C diam. 85 mm Reproducibility >1g 0.05% 0.10% 0.20% 0.5%

E & OE.

Reproducibility >5 g 0.01% 0.02% 0.05% 0.1%

PK

1 1 1 1

Cat. No.

9.901 9.901 9.901 9.901

541 542 543 544


GENERAL CATALOGUE 2010/11

3. Analytical measurement and testing Balances/Moisture balances-Accessories

1 2 Aluminium sample dishes

1

Ideal for use with infrared moisture analysers. Samples can be evenly distributed horizontally to absorb heat uniformly over the entire dish area. Can also be used as laboratory dishes.

Dia. mm 100 100

Height mm 7 8

PK

Cat. No.

80 50

9.106 265 6.236 854

3 Calibration weights, class M1

3

Brass, finely turned (also available in stainless steel). Plastic box with internal foam support available on request. Also available with internationally recognised DKD calibration certification on request. Weight g 1 2 5 10 20 50 100 200 500 1000 2000 5000 10000

2

Accuracy Âą mg 1.0 1.2 1.5 2.0 2.5 3.0 5.0 10 25 50 100 250 500

Kern & Sohn

PK 1 1 1 1 1 1 1 1 1 1 1 1 1

Cat. No. 9.900 9.900 9.900 9.900 9.900 9.900 9.900 9.900 9.900 9.900 9.900 9.900 9.900

501 502 505 510 512 515 520 522 525 531 532 535 540

Also available: Single weights from 1mg - 2000 kg or complete weight sets from 1mg - 10kg in OIML-classes E1, E2, F1, F2, M1, M2, M3.

4 Calibration weights, class F1

4

Nickel plated brass (also available in stainless steel). Plastic box with internal foam support available on request. Also available with internationally recognised DKD calibration certification on request. Weight g 1 2 5 10 20 50 100 200 500 1000 2000 5000 10000

Accuracy Âą mg 0.1 0.12 0.15 0.2 0.25 0.3 0.5 1.0 2.5 5.0 10.0 25.0 50.0

Kern & Sohn

PK 1 1 1 1 1 1 1 1 1 1 1 1 1

Cat. No. 9.900 9.900 9.900 9.900 9.900 9.900 9.900 9.900 9.900 9.900 9.900 9.900 9.900

566 567 568 569 570 571 572 573 574 575 576 577 578

Also available: Single weights from 1mg to 2000 kg or complete weight sets from 1 mg to 10 kg in OIML-classes E1, E2, F1, F2, M1, M2, M3

5 Weighing scoops

5

Glass. Ideal for powders or granules which are dispensed via the tubular stem.

Capacity ml 3 6 10

E & OE.

PK

Cat. No.

1 1 1

9.301 066 9.301 067 9.301 068

307


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Balances/Accessories 1

1 Weighing scoops Without counterweight. Length mm 70 90 105 60 80 100

2

Kern & Sohn

Material

PK

Aluminium Aluminium Aluminium Glass Glass Glass

1 1 1 1 1 1

Cat. No. 9.301 9.301 9.301 9.301 9.301 9.301

006 008 010 026 028 030

2 Kjeldahl weighing boats 609 Ideal for weighing and transporting all types of sample. Especially for determination of Whatman nitrogen according to Kjeldahl (e.g. determination of total protein content in foodstuff). Made of nitrogen-free parchment paper. Can be dropped into the Kjeldahl flask and be dissolved together with the sample. Width mm 10

Length mm 55

Height mm 10

PK

Cat. No.

100

9.069 011

Weighing bottles Duran速. DIN 12605. With interchangeable standard ground joint stopper, fused ceramic matt marking area, statement of volume and dimensions marked permanently on each weighing bottle.

3

3 Weighing bottles Low form. Capacity ml 6 15 15 30 45 80

4

Bottom dia. mm 25 40 35 50 60 80

Height

PK

mm 25 25 30 30 30 30

1 1 1 1 1 1

Height

PK

mm 40 50 70 80 80

1 1 1 1 1

Cat. No.

9.300 9.300 9.300 9.300 9.300 9.300

022 021 023 032 037 041

4 Weighing bottles Tall form. Capacity ml 10 20 45 70 110

5

Bottom dia. mm 25 30 35 40 50

Cat. No.

9.300 9.300 9.300 9.300 9.300

113 118 123 124 127

5 6 Aluminium sample dishes Ideal for use with infrared moisture analysers. Samples can be evenly distributed horizontally to absorb heat uniformly over the entire dish area. Can also be used as laboratory dishes.

Dia. mm 100 100

Height mm 8 7

6

308

E & OE.

PK

Cat. No.

50 80

6.236 854 9.106 265


GENERAL CATALOGUE 2010/11

3. Analytical measurement and testing Balances/Accessories

1 Weighing boats

1

Polystyrene, disposable. Available in black or white. Capacity ml 30 100 30 100

Cope

Colour

PK

White White Black Black

500 250 500 250

Cat. No. 9.950 9.950 9.950 9.950

190 191 192 193

2 Weighing boats

2

Polystyrene, disposable. Antistatic, manufactured to eliminate the problems caused by static build-up when weighing fine powders. Capacity ml 30 100 30 100

Colour

PK

White White Black Black

500 250 500 250

Cat. No. 9.950 9.950 9.950 9.950

194 195 196 197

3 Hexagonal Weighing Boats

3

Bend flexible boats at points to form pour spouts. Flat bottoms and sloping sides provide accurate transfer. These antistatic, polystrene boats are inert to most substances. Resist temperatures up to 150째C. Top dia. mm 38 64 102 127

Bottom dia. mm 25 51 76 89

PK

500 500 500 500

Cat. No.

9.900 9.900 9.900 9.900

893 894 895 896

4 Weighing boats

4

Polystyrene. Capacity ml 7 100 250 5 7 100 250 5

Dimensions mm 44 x 44 80 x 80 140 x 140 Diamond shaped 44 x 44 80 x 80 140 x 140 Diamond shaped

Colour

PK

White White White White Black Black Black Black

1000 1000 1000 1000 1000 1000 1000 1000

Cat. No. 9.900 9.900 9.900 9.900 9.900 9.900 9.900 9.900

792 794 796 795 780 781 782 783

5 Weighing boats

5

Polystyrene. Antistatic. Capacity ml 7 100 250 5 7 100 250 5

Dimensions mm 44 x 44 80 x 80 140 x 140 Diamond shape 44 x 44 80 x 80 140 x 140 Diamond shape

Colour

PK

White White White White Black Black Black Black

1000 1000 1000 1000 1000 1000 1000 1000

Cat. No. 9.900 9.900 9.900 9.900 9.900 9.900 9.900 9.900

785 786 787 788 789 791 800 801

6 Weighing bottles

6

PP. Transparent. with push-on lid. Capacity litres 30 25 65 65 50 200 400

Dia. mm 30 40 40 60 50 60 70

Kartell

Height mm 50 30 60 35 30 90 120

PK 1 1 1 1 1 1 1

E & OE.

Cat. No. 9.300 9.300 9.300 9.300 9.300 9.300 9.300

805 810 815 820 825 830 835

309


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Balances/Accessories 1

1 Planar weighing apparatus Glass. For all weighing procedures involving the dispersal of material into a thin layer. Type Planar weighing apparatus

2

PK

Cat. No.

1

9.300 500

2 Weighing boats MN808 MACHEREY-NAGEL Paper Dimensions:

58 x 10 x 10 mm

Type MN808

3

Cat. No.

100

9.301 069

3 Weighing paper Block of 100 sheets. Type MN 226

4

PK

Width mm 90

MACHEREY-NAGEL Length mm 115

PK

Cat. No.

100

9.058 975

4 Weighing table, TWK I High quality weighing table for damping the effects of harmonic and impact vibrations when using sensitive microbalances. Tubular steel frame with wood-block cladding. The weighing platform is constructed in shockabsorbing, artificial stone. With integral drawer for weighing utensils. Damping approx. 7.5% at 5.5-16Hz vertical and horizontal frequency. Width mm 900

5

Depth mm 600

Height mm 750

PK

Cat. No.

1

9.733 060

5 Weighing table, TWK II Robust weighing table for use with ultramicro balances or vibration-sensitive equipment to dampen vibrations caused by resonance or impact shock. Solid, artificial stone block construction. Damping approx. 7.5% at 13-29 Hz vertical and horizontal frequency. Width mm 900

6

Depth mm 600

Height mm 750

PK

Cat. No.

1

9.733 070

6 Weighing table For positioning of analytical balances. Vibration-free even for smallest sample quantities. Description Weighing table

310

Width mm 900

Depth mm 600

E & OE.

Height mm 750

Kรถttermann PK

Cat. No.

1

9.731 285


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Balances/Accessories-Thermometers/Laboratory thermomters 1 Anti-vibration platform, Vibrasorb

1

For absorbing and damping vibrations down to 9 Hz. Comprises a moulded terazzo slab supported on four vibration absorbers with non-slip feet. Suitable for isolating sensitive analytical instruments such as balances and microscopes. Will support up to 16 kg. Weight: 39 kg.

Bel-Art Products

Type

PK

Cat. No.

1

9.951 600

Width mm 450

Vibrasorb

Depth mm 560

Height mm 76

2 General-purpose thermometers

2

Enclosed-scale type, with eyelet, 7 to 8 mm dia. With uncoated, prismatic measuring capillary. Red spirit filling (except 9.235 265: blue). Resolution 1°C. Measuring range °C -10/0 to +50 -10/0 to +100 -10/0 to +150 -10/0 to +200 * -10/0 to +250 *

Length

PK

mm 200 260 260 300 300

1 1 1 1 1

Cat. No.

9.235 9.235 9.235 9.235 9.235

245 250 255 260 265

*Note: With these types the colour can fade after extended periods of use at higher temperatures.

3 General-purpose thermometer

3

Enclosed-scale type, with eyelet, 7 to 8 mm diameter. Environmentally friendly thermometer, with biodegradable filling. Uncoated, prismatic measuring capillary. Green spirit filled. Measuring range °C -10 to +110 -10 to +110 -10 to +150 -10 to +250 -10 to +360

Graduations °C 1.0 0.5 1.0 2.0 2.0

Length

PK

mm 300 300 300 300 300

1 1 1 1 1

Cat. No.

9.235 9.235 9.235 9.235 9.235

271 272 273 274 270

4 General-purpose thermometers

4

Glass, solid stem, with loop, 7 to 8 mm diameter, white backed. Environmentally friendly thermometer, with biodegradable, green spirit filling. Partial immersion (76 mm). Measuring range °C -10 / 0 to +110 -10 / 0 to +110 -10 / 0 to +150 -10 to +250 -10 to +360

Graduations °C 1.0 0.5 1.0 2.0 2.0

Length

PK

mm 300 300 300 300 300

1 1 1 1 1

E & OE.

Cat. No.

9.235 9.235 9.235 9.235 9.235

275 276 277 278 279

311


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Laboratory thermomters 1 Laboratory thermometers

1

Suitable for official calibration. Enclosed scale type, 8 to 9 mm dia. Richter seal with button. Available mercury-filled, with prismatic, luminous blue, measuring capillary or red spirit filled with uncoated capillary. Total immersion.

Measuring range °C -5/0 to +50 -10/0 to +50 -10/0 to +100 -10/0 to +100 -10/0 to +250 -5/0 to +50 -5/0 to +100 0 to +50 0 to +100

2

Length Resolution mm 220 220 270 270 420 350 420 420 550

°C 1/ 1/ 1/ 1/ 1/ 1/ 1/ 1/ 1/

2 2 2 2 2 5 5 10 10

Filling

PK

mercury red spirit mercury red spirit mercury mercury mercury mercury mercury

1 1 1 1 1 1 1 1 1

Cat. No.

9.235 9.235 9.235 9.235 9.235 9.235 9.235 9.235 9.235

405 495 410 496 425 450 455 485 490

2 Laboratory thermometers To DIN standards as indicated. Calibrated with state certificate. Enclosed scale type, 8 to 9 mm diameter. Prismatic measuring capillary, uncoated. Mercury filled. Measuring range °C 0 to +50 0 to +50 0 to +50 0 to +100 0 to +100 0 to +100 0 to +100 0 to +150 0 to +250 0 to +360

3

Resolution °C 1/ 1/ 1/ 1/ 1/ 1/ 1/ 1/ 1/ 1/

2 10 5 2 1 5 10 1 1 1

Length

DIN

PK

mm 220 420 350 270 305 420 550 305 350 380

12775 12775 12775 12775 12775 12775 12775 12775 12778 12778

1 1 1 1 1 1 1 1 1 1

Cat. No.

9.235 9.235 9.235 9.235 9.235 9.235 9.235 9.235 9.235 9.235

505 545 546 510 547 548 549 550 525 536

3 Environmental thermometers with PTFE jacket Suitable for official calibration (1- to 6-point). With mercury protection (optimal protection against glass splinters and mercury contamination in case of breakage due to double-walled, welded, transparent PTFE jacket). Temperature resistant up to 200°C. Enclosed scale type. Prismatic, luminous blue, measuring capillary. Total immersion. Mercury filled. Measuring range °C 0 to +100 0 to +150 0 to +200 -5 to +100 -5 to +100 -10 to +50 -30 to +50 -10 to +100 -10 to +200

312

Resolution °C 1/ 1/ 1/ 1/ 1/ 1/ 1/ 1/ 1/

1 1 1 2 5 10 1 1 1

Length

PK

mm 305 305 305 270 420 420 260 260 300

1 1 1 1 1 1 1 1 1

E & OE.

Cat. No.

9.235 9.235 9.235 9.235 9.235 9.235 9.235 9.235 9.235

081 082 083 084 085 086 087 088 089


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Laboratory thermomters 1 Pocket thermometers

1

Red spirit filled glass thermometers with nickel-plated, double plug collar which locks the thermometer into its case or allows the case to connect to the top of the thermometer as an extenson handle. Approx. dimensions when fitted into case: 140 x 11.5 mm diameter, with pocket clip. With uncoated prismatic measuring capillary. Graduated every 1°C. Measuring range °C -35 to +50 -10 to +100

PK

Cat. No.

1 1

9.239 001 9.239 002

2 Maximum thermometers for whirling, enclosed scale

2

With shake-down reset. Enclosed scale type, 7 to 8mm dia. With luminous blue, prismatic measuring capillary. Mercury filled. Resolution 1°C. Measuring range °C -10 to +100 -10 to +150 -10 to +250

Length

PK

Cat. No.

mm 260 260 300

1 1 1

9.235 910 9.235 915 9.235 925

3 Thermometers, ground glass joint

3

With NS14.5/23 cone. To DIN 12784. With fixed immersion (immersion length = lower section + ground joint). Enclosed-scale type, NS 14.5/23. Translucent glass scale. Upper section approx. 11 mm dia., lower section 7.5 mm dia. Richter-top finish seal without button. Suitable for official calibration. Graduated every 1°C.

Measuring range

Corpus

°C -10 -10 -10 -10 -10 -10 -10 -10

mm 250 350 300 350 250 350 300 350

to to to to to to to to

+150:1 +150:0.5 +250:1 +360:1 +150:1 +150:0.5 +250:1 +360:1

Immersion Charge length mm 75 75 75 75 100 100 100 100

PK

colour red red blue green red red blue green

1 1 1 1 1 1 1 1

E & OE.

Cat. No.

9.236 9.236 9.236 9.236 9.236 9.236 9.236 9.236

021 022 023 024 025 026 027 028

313


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Laboratory thermomters 1 Enclosed-scale thermometers

1

With 8 mm diameter stem. With cork seal, round collar, upper section approx. 235 x 20 mm. Prismatic, yellow measuring capillary. Available either Mercury filled, or red, blue or green spirit-filled. Translucent glass scale. Graduated every 1°C (except 0 to +300°C/+360°C range thermometers which are graduated every 2°C).

Measuring range °C -30 to +50 -30 to +50 -30 to +50 -30 to +50 -30 to +50 -30 to +50 -30 to +50 0 to +100 0 to +100 0 to +100 0 to +100 0 to +100 0 to +100 0 to +100 0 to +100 0 to +100 0 to +160 0 to +160 0 to +160 0 to +160 0 to +160 0 to +160 0 to +160 0 to +160 0 to +160 0 to +200 0 to +200 0 to +200 0 to +200 0 to +300 0 to +300 0 to +300 0 to +300 0 to +300 0 to +360 0 to +360

2

Length Filling mm 105 105 165 165 213 213 303 105 105 165 165 213 213 303 303 405 105 105 165 165 213 213 303 303 405 105 105 213 213 165 213 213 303 405 105 213

PK

mercury red spirit mercury red spirit mercury red spirit mercury mercury red spirit mercury red spirit mercury red spirit mercury red spirit mercury mercury red spirit mercury red spirit mercury red spirit mercury red spirit mercury mercury red / blue spirit mercury red / blue spirit mercury green spirit mercury mercury mercury green spirit green spirit

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Cat. No.

9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238 9.238

010 345 015 346 020 347 030 110 350 115 351 120 352 130 354 140 210 355 215 356 220 357 230 359 240 250 360 260 362 315 367 320 330 340 370 372

2 Low temperature thermometers Suitable for official calibration. Enclosed scale type, 8 to 9 mm diameter, with Lab Logistics Group translucent glass scale and Richter seal. Prismatic, uncoated measuring capillary. The -200 to +30°C thermometer has a luminous blue measuring capillary, and is pentane filled. Further thermometers are available, red toluene filled with uncoated measuring capillary. Graduated every 1°C. Measuring range °C -50 to +50 -100 to +30 -200 to +30

314

Length

PK

Cat. No.

mm 300 300 300

1 1 1

9.235 705 9.235 710 9.235 720

E & OE.


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Laboratory thermomters Standard thermometers Exact-Temp, red spirit-filled For

Freezers Refrigerators Blood banks Coolers Incubators Warming rooms, ovens Warming rooms, ovens

Measuring range °C -90 to +20 -30 to 0 -5 to +20 -5 to +15 +18 to +50 +20 to +130 +35 to +200

Grad.

Length Liquid filling

°C 1.0 0.5 0.5 0.5 0.5 1.0 1.0

mm 145 125 145 125 135 135 145

PK

Propylene Glycol Propylene Glycol Ethylene Glycol Ethylene Glycol Ethylene Glycol Vermiculite Vermiculite

1 1 1 1 1 1 1

Cat. No.

9.235 9.235 9.235 9.235 9.235 9.235 9.235

663 664 665 666 667 668 669

Exact-Temp Standard thermometers, mercury-filled For

Freezers Refrigerators Incubators Warming rooms, ovens Warming rooms, ovens

Measuring range °C -30 to 0 -5 to +15 +18 to +50 +20 to +130 +35 to +200

Grad.

Length Liquid filling

°C 0.5 0.5 0.5 1.0 1.0

mm 115 125 135 135 145

PK

Propylene Glycol Ethylene Glycol Ethylene Glycol Vermiculite Vermiculite

1 1 1 1 1

Cat. No.

9.235 9.235 9.235 9.235 9.235

670 671 672 673 674

Precision thermometers Exact-Temp, blue spirit-filled For

Freezers Refrigerators Blood banks Incubators Incubators Warming rooms, ovens

Measuring range °C -25 to -5 -2 to +10 -2 to +10 +15 to +30 +25 to +45 +95 to +115

Grad.

Length Liquid filling

°C 0.1 0.1 0.1 0.1 0.1 0.1

mm 210 180 180 180 190 200

PK

Propylene Glycol Propylene Glycol Ethylene Glycol Ethylene Glycol Ethylene Glycol Vermiculite

1 1 1 1 1 1

Cat. No.

9.235 9.235 9.235 9.235 9.235 9.235

675 676 677 678 679 680

Precision thermometers Exact-Temp, mercury-filled For

Cold rooms, Freezers Refrigerators Blood banks Incubators Incubators Warming rooms, ovens

Measuring range °C -25 to -5 -2 to +10 -2 to +10 15 to 30 25 to 45 95 to 115

Grad.

°C 0.1 0.1 0.1 0.1 0.1 0.1

Length Liquid filling mm 210 180 180 180 190 200

PK

Propylene Glycol Propylene Glycol Ethylene Glycol Ethylene Glycol Ethylene Glycol Vermiculite

1 1 1 1 1 1

1 Refrigerator thermometer

Cat. No.

9.235 9.235 9.235 9.235 9.235 9.235

681 682 683 684 685 686

1

Plastic, with loop or hook clip mountings. Measuring range -40 to +40°C. Graduated every 1°C. Dimensions (L x dia.) 185 x 20 mm. Type Refrigerator thermometer

E & OE.

PK

Cat. No.

1

9.242 340

315


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Laboratory thermomters 1

1 Max./Min. thermometers Six's pattern. Measuring range: -30 to +50°C.

Type

Width mm 90

With cover and push-button magnet, on plastic plate

2

Length mm 200

PK

Cat. No.

1

9.241 130

PK

Cat. No.

1

9.241 134

2 Max/Min Thermometer - ivory plastic - with push button - mercury-free Dimensions: Weight:

230 x 60mm 120g

Type Mmaxima-Minima-Thermometer

3

3 Irreversible temperature strips Thermax strips, 8-step. 5 types cover the measuring range +37 to +280°C, each strip displays 8 different temperatures (8 temperature changing points). Each strip measures 51 x 18 mm. Type

06460108 06460916 06461724 06462532 06463341 06460005

4

Measuring range °C +37 to +65 +71 to +110 +116 to +154 +161 to +204 +204 to +260 +249 to +280

Testo

PK

10 10 10 10 10 10

Cat. No.

9.246 9.246 9.246 9.246 9.246 9.246

002 003 004 005 006 007

4 Irreversible temperature strips 5-step irreversible temperature measuring strips covering the temperature range 29 to 290°C. Each strip measures 35 x 15 mm. Type

S A B C D E F G H I

316

Measuring range °C +29 to +40 +37 to +46 +49 to +71 +77 to +99 +104 to +127 +132 to +154 +160 to +182 +188 to +210 + 216 to +249 +249 to +290

PK

10 10 10 10 10 10 10 10 10 10

E & OE.

Cat. No.

9.246 9.246 9.246 9.246 9.246 9.246 9.246 9.246 9.246 9.246

310 311 312 313 314 315 316 317 318 319


GENERAL CATALOGUE 2010/11

3. Analytical measurement and testing Thermometers/Laboratory thermomters

1 Mini-Thermometer

1

Dipping/penetration thermometer for measuring the temperature in air, soft or powdery materials and liquids. Specifications Measuring range: -50 to +250°C Accuracy (±1 Digit): ±1°Χ (−10 το +99.9°Χ) ±2% ϖ.Μω. (+100 το +199.9°Χ) ±3% ϖ.Μω. (+200 το +250°Χ) Readabilty: 0.1°C (-19.9 to +199.9°C) 1°C (remaining range) Operating range: -10 to +50°C Service life: 150 hours Protection class: IP67 Batterie: Coin cell battery LR44, 1.5 volt

Description Coin cell battery LR44, 1.5 volt Mini-Thermometer

Testo

2

PK

Cat. No.

2 1

9.012 932 9.243 141

2 Digital window thermometer Vision With large display, for outdoor temperature (-25°C to 70°C), maximum and minimum values with auto reset, weather resistant casing, adhesive mounting pad and battery 1.5 V AAA included

3 Type Vision thermometer

PK

Cat. No.

1

9.241 133

3 Maximum/Minimum Indoor/outdoor thermometer Optimal for controlling of freezer temperature. - 50 to +70°C in 0.1°C. External remote sensor cable, length 3 metres, with stand and accessories for wall mounting. Dimensions: approx. 80 x 55 x 20 mm, with battery.

Type Maximum/Minimum Indoor/outdoor thermometer

E & OE.

Amarell

PK

Cat. No.

1

9.235 120

317


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Laboratory thermomters-Contact, Insertion themometers 1

1 Digital Max./Min. Thermometer Digital thermometer, wall hanging, for indoor or outdoor use. With blue, splash-proof casing, selectable °C/°F ranges and battery. weight: 161g Measuring range °C -50 to +70

Width

Depth

Height

PK

Cat. No.

mm 75

mm 44

mm 115

1

9.241 131

2

2 Laboratory Max./Min. thermometer Display of current, highest and lowest temperature, hold function, alarm at freely adjustable temperature values (upper/lower limit), measuring range -50 to +70°C, accuracy ±0.5°C at -20 to +25°C, otherwise ±1°C, selectable °C/°F readout. Supplied with table stand and magnet, probe with 3m cable and 3V Lithium CR2032 button cell

Type Laboratory Max./Min. thermometer

3

PK

Cat. No.

1

9.851 022

3 Support Labo-Clip Stable support for clamping test tubes, thermometers, pH electrodes and other Amarell laboratory instruments onto laboratory containers (e.g. beakers). Extensive chemical resistance, with strong flexible foam rubber plate perforated with 5 apertures of varying diameters. Metal components are corrosion-resistant.

Type Labo-Clip

4

Cat. No.

1

9.234 990

4 Digital Thermometer SA 880 SSX -

display: Temperature measuring range: -50°C to +250°C sensor: 96mm long, stainless steel probe resolution: 0.1°C to 0.5°C °C and °F selectable measuring update: 1 or 10sec. alarm: upper and lower temperature value programmable with table stand and wall mounting 1 x 1.5V AAA battery dimensions: 107 x 59 x 20mm weight: 100g

Type SA 880 SSX

318

PK

E & OE.

Oregon Scientific

PK

Cat. No.

1

9.243 135


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Contact, Insertion themometers 1 Contact thermometers

1

With MS 121st2 flat plug. Measuring range 째C 0 to +100 -20 to +150 0 to +100 -20 to +150 0 to +250 0 to +100 -20 to +150 0 to +250 -20 to +150 0 to +250 -20 to +150 0 to +250 -20 to +150 0 to +250

Heju

Grad.

Length*

PK

째C 1 1 1 1 2 1 1 2 1 2 1 2 1 2

50 50 100 100 100 150 150 150 200 200 250 250 300 300

1 1 1 1 1 1 1 1 1 1 1 1 1 1

Cat. No.

9.233 9.233 9.233 9.233 9.233 9.233 9.233 9.233 9.233 9.233 9.233 9.233 9.233 9.233

010 015 110 115 125 210 215 225 315 325 345 347 365 367

* Probe length (mm)

2 Contact thermometers

2

With diode plug MS 121st3. Measuring range 째C -20 to +150 0 to +250 -20 to +150 0 to +250 0 to +250

Heju

Grad.

Length*

PK

째C 1 2 1 2 2

100 100 150 150 200

1 1 1 1 1

Cat. No.

9.233 9.233 9.233 9.233 9.233

116 126 216 226 326

* Probe length (mm)

Contact thermometers, accessory connecting cable With flat coupling and diode connection for relay. Length 0.8 metres.

Heju

For Contact thermometers with flat plug MS 121st2 Contact thermometers with diode plug MS 121st3

E & OE.

PK

Cat. No.

1 1

9.233 400 6.091 756

319


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Contact, Insertion themometers 1

2

1 2 Universal digital thermometers, Maxi-T and Maxi-Pen Water-proof casing. Measuring range -50 to 200°C x 0.1°C, switchable to °F. Maximum-minimum memory, hold function and 125 x 3.5 mm stainless steel penetration probe. With battery. Type Maxi-T Maxi-Pen

3

PK

Cat. No.

1 1

9.243 120 9.243 121

3 Food and frozen goods thermometers For measurements according to the EU Directive concerning the control of foodstuffs (HACCP). Waterproof, IP65protection level, can be rinsed. With battery.

Testo

Type 105. One-handed, penetration thermometer. Sensor (Dia. x L): 5 x 100mm Measuring tip dia.: 3.5 mm Accuracy: -20 to +70°C: ±0.8°C rest of range: ±2°C. Type

105

4

Measuring range °C -40 to +230

PK

Cat. No.

1

9.718 002

4 Temperature Probe Lemo-Compact Pt100 Temperature probe with integral Lemo-connector. Particularly useful for measuring temperature in aggressive media (temperature range: -200°C to +250°C). The temperature element is located in a stainless steel core which is entirely sealed in a solid and seamless PTFE coating. This provides high chemical resistance and rigidity, however, the probe can be bent manually to the desired shape. The tip of the probe is narrower (6mm dia.) for faster measurement response. Connector: 1 x Lemo, size 1, connector with 4 cores. The connector is situated directly at the end of the probe so that it can be used for further applications without removing any cables.

320

Dia.

Length

mm 8 8 8 8

mm 170 370 470 570

Effective length mm 100 300 400 500

PK

1 1 1 1

E & OE.

Bohlender

Cat. No.

9.243 9.243 9.243 9.243

221 222 223 224


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Contact, Insertion themometers 1 Double Temperature Probe Pt100 Lemo Compact

1

Temperature probe with two independent temperature elements and two Bohlender Lemo-connectors. Particularly useful for parallel evaluation of values measured in aggressive media (temperature range: -200°C to +250°C). The temperature elements are located in a stainless steel core which is entirely sealed in a solid and seamless PTFE coating. This provides high chemical resistance and rigity, however, the probe can be bent manually to the desired shape. The tip of the probe is smaller (6mm dia.) for faster measurement response. 2 x Lemo size 1 connectors, with 4 cores. Both connectors are situated directly at the end of the probe. It can easily be used for further applications without removing any cables.

Dia.

Length

mm 8 8 8

mm 400 500 600

Effective length mm 300 400 500

PK

Cat. No.

1 1 1

9.243 226 9.243 227 9.243 228

2 Digital thermometer, Checktemp C

2

With very high measurement accuracy of ±0.3°C (-20 to +90°C) and integral stainless steel insertion probe. Equipped with the unique "Checkcal" function which tests internal instrument electronics when the Checktemp is switched on. Range: Resolution: Accuracy:

Hanna

-50 to +150°C 0.1°C ±0.3°C (-20 to 90°C) ±0.5°C (rest of range) 170 x 50 x 25mm 105 x 3mm 100g

Overall L x W x H: Probe L x dia.: Weight: Type Checktemp C

PK

Cat. No.

1

9.950 179

3 Digital thermometer Checktemp 1 C

3

With very high measurement accuracy of ±0.3°C (-20 to +90°C) and integral stainless Hanna steel insertion probe with handle and 1 metre cable, ensuring flexibility in use. Equipped with the unique "Checkcal" function which tests internal instrument electronics when the Checktemp 1 is switched on. Specifications Range: Resolution: Accuracy: Overall L x W x H: Probe length L x dia.: Weight:

-50 to +150°C 0.1°C ±0.3°C (-20 to 90°C) ±0.5°C (rest of range) 170 x 50 x 25 mm 106 x 3 mm 80 g

Type Checktemp 1 C

PK

Cat. No.

1

9.950 180

4 Thermometer Checkfridge

4

-specially designed to monitor the internal temperature of freezers and refrigeration units - magnetic backing provides an easy way to attach the thermometer to all metal refrigerators and freezers - the sensor with 1 metre cable can be easily placed within the freezer/fridge cabinet - Very high accuracy - The unique Cal Check Function enables the user to check the internal electronics of the thermometer Specifications: Measuring range: -50 to +150°C Accuracy: ±0.3°C (-50 to +90°C) Probe: 40 x 5mm, with 1 metre cable Battery type: 1 x 1.5 V Weight: 100 g Type Checkfridge

E & OE.

Hanna

PK

Cat. No.

1

9.851 098

321


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Contact, Insertion themometers 1

1 Digital thermometer, pocket, "Multi" Range: -50 to +200°C, resolution 0.1°C. Suitable for most laboratory applications. With stainless steel probe (L x diameter) 125 x 3.5 mm (Also available with probe length 300/500 mm). Hold function with memory for instantaneous display, on/off switch and automatic switch off. Supplied with protective case and probe clip. Battery life approx. 5000 hours. Type Multi digital thermometer, pocket

2

PK

Cat. No.

1

9.243 108

2 Core thermometer Ideal for quick, simple core temperature measurements in various fields, e.g. restaurants, hotels, service kitchens, supermarkets etc. Wide measurement range and highly accurate. With Auto-Hold function for final reading. Includes sensor protection cap and battery. Calibration certificate on request.

Testo

The testo 106-T1 kit also contains a TopSafe protective case and a holster clip for belt or wall.

Specifications Temperature range (°C): Accuracy ±1 digit (°C):

Resolution (°C): Battery type:

-50 to +275 ±1% of measurement value (+100 to +275) ±0.5 (-30 to +99.9) ±1 (-50 to +230) 0.1 Lithium (CR2032)

Type

3

Testo 106 Testo 106-T1 Kit

PK

Cat. No.

1 1

9.718 208 9.718 209

3 Accessories for core thermometer testo 106 Testo

Type

Description

TopSafe protective sleeve (IP67)

water-tight, dishwasher-safe

322

E & OE.

PK

Cat. No.

1

9.718 232


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Contact, Insertion themometers 1 2 Thermometers TFN-Series

1

1- or 2-Channel thermometers for use with thermocouples (Type K, J, T, E) TFN 520/TFN 520 SMP/TFN 530/TFN 530 SMP

ebro

Ex-proof versions also available! Applications: Heating/Air-conditioning, ventilation/Air, gases, fluids/Surface temperature/Plastic materials/Laboratories Attributes: - Robust and impact resistant - Min/Max, Hold facility - °C/°F selectable - Battery charge status indicator - Changeable battery - Factory calibration certificate

2

Measuring range Type K Measuring range Type J Measuring range Type T Measuring range Type E Accuracy at +25°C, Type Accuracy at +25°C, Type Accuracy at +25°C, Type Accuracy at +25°C, Type Resolution Resolution Resolution Resolution

Type Type Type Type

K J T E

K J T E

Protection class: Dimensions: Housing: Weight: Sensor: Sensor connection: Number of channels: Battery: Measuring rate:

-200 to +1200°C -100 to +800°C -50 to +300°C -100 to +600°C ±0.3°C (-100 to +250°C) ±0.3°C (-50 to +190°C) ±0.3°C (-50 to +220°C) ±0.3°C (-50 to +150°C) ±0.5 % for remaining range 0.1°C (-200 to +250°C) 0.1°C (-100 to +190°C) 0.1°C ( -50 to +220°C) 0.1°C ( -100 to +150°C ) 1°C for remaining range IP 67 (TFN 520/TFN 530); IP 40 (TFN 520 SMP/TFN 530 SMP) 115 x 54 x 22 mm ABS approx. 90 g external; thermocouple Type K, J, T, E LEMO (TFN 520/TFN 530); SMP (TFN 520 SMP/TFN 530 SMP) 1 (TFN 520/TFN 520 SMP); 2 (TFN 530/TFN 530 SMP) Lithium, 3 V; battery life approx. 5 years 0.5 to 15 secs.

Type

Description

TFN 520 TFN 520-SMP TFN 530 TFN 530-SMP TPN 211 TPN 341 TPN 140 TPN 360

Thermometer (Lemo connection) Thermometer (SMP Connection) Thermometer (Lemo Connection) Thermometer (SMP Connection) Penetration probe, SMP Paddle probe, SMP Rod probe, 3 mm dia., 185 mm length, Lemo Surface probe up to 500°C, 15 mm dia., 30 mm length, 1m silicone cable, Lemo Penetration probe up to 500°C, 2.1mm dia., 100 mm length, silicone cable, Lemo

TPN 230

PK

E & OE.

Cat. No.

1 1 1 1 1 1 1 1

9.908 9.908 9.908 9.908 9.908 9.908 9.908 9.908

060 061 062 063 064 065 066 067

1

9.908 068

323


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Contact, Insertion themometers 1 Electronic Contact Thermometer GFX 460

1

Applications: - control of magnetic stirrers, stirrer/hotplates, etc. - laboratory - process monitoring

ebro

Attributes: - high accuracy through Fuzzy logic algorithm - minimizes temperature overshoot - suitable for all magnetic stirrers Safety features: Probe failure identification, Probe limit warning. Safety and control circuit according to DIN 12878 Class 1 and 2 Specifications Measuring range: -50 to +300°C Resolution: 1°C Accuracy: ±1°C Measuring rate: 1s Measuring probe: Pt1000 Operating temperature: -5 to +60°C Storage temperature: -30 to +70°C Type of control: Fuzzy logic control Protection class: IP 65 Connection: 5-pin diode plug DIN 45322 Display: Background illumination LED display for control status Power supply: external 9-12V d.c., 20mA Dimensions (WxDxH): 54 x 22 x 110 mm without probe Housing material: Polyamide, acid-resistant Weight: approx. 150g Type

Description

GFX 460

with V2A probe 205 x 3 mm L x dia. with glass-coated probe 235 x 7 mm L x dia.

GFX 460 G Adapter Relay box

2

PK

Cat. No.

1

9.908 056

1

9.908 057

1 1

9.908 058 9.908 059

2 3 Infrared thermometer Mini-Flash II Compact and easy to use. Surface temperatures of hazardous samples or hard-to-reach objects can safely be measured within 0.5 seconds. Features - switchable °C/°F ranges - memory for maximum/minimum values - hold function maintains reading automatically for 15 seconds - lock function for long-term monitoring - supplied with key ring Measuring range: Accuracy: Resolution: Response time: Emissivity: Battery: Dimensions: Weight:

3

-33°C to +220°C ±1.5°C 0.1°C 500 msec. 0.95 1 x cell CR2032 68 x 37 x 18mm 80g (incl. packaging)

Type Mini-Flash II

324

E & OE.

PK

Cat. No.

1

9.851 026


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Contact, Insertion themometers 1 ScanTemp 410

1

Infra-red thermometer with laser aiming. For quick, easy and safe measurement of surface temperatures. Easy to use: just point, press the button and read the measurement from the large, illuminated display. Specifications Temperature range Precision Response time Spectral sensitivity Operating temperature Optical resolution Laser Dimensions (L x W x H) Weight Battery:

-33°C to 500°C ±2 % of measurement or 2°C 0.5 secs. 7 to 18µm 0 to 50°C 11:1 Spot laser 175 x 39 x 79 mm 300 g (incl. packaging) 2 x 1.5V AAA Batteries

Type Scan Temp 410

PK

Cat. No.

1

9.851 919

2 Infrared thermometer, Dualtemp Pro, with penetration probe

2

For simple, rapid, non-contact, temperature measurement. - dual display - wide measurement ranges: - infra-red: -33 to +220°C - conventional penetration probe: -55 to + 220°C - measuring spot:distance ratio 3:1 - Max./ Min., Hold functions - auto-off after 15 secs. - belt-clip included - accessories: certificate of calibration & pilot drill for taking measurements from frozen items Resolution of display: Accuracy (IR): Accuracy (penetration probe): Spectral sensitivity: Adjustable emissivity: Operating temperature: Battery: Dimensions: Weight:

0.1°C ±2% or 2°C, whichever is largest ±1% or ±1°C 6 to 14µm 0.10 to 1.00 0 to 50°C Lithium cell CR2032 24.2 x 39.8 x 156mm 380g (incl. packaging)

Type Dualtemp Pro

E & OE.

PK

Cat. No.

1

9.851 023

325


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Contact, Insertion themometers 1

1 2 Infra-red thermometers, testo 830 series Testo 830-T1 Infra-red thermometer with 1-point laser sighting, adjustable limit values and alarm function

Testo

Testo 830-T2 Infra-red thermometer with 2-point laser sighting, adjustable limit values, alarm function and connection of external probes Testo 830-T2 Set Infra-red thermometer testo 830-T2 incl. surface sensor and protective leather case. Testo 830-T3 IR temperature meter with close focus optics, incl. 2-point laser sighting, adjustable limit values, alarm function and alternative contact sensor probe socket, incl. battery Technical Specifictations Accuracy: Testo 830-T1/T2:

2

±1 digit at +23°C ambient temperature ±1.5°C or 1.5% of meas. value (+0.1 to +400°C) ±2°C or ±2% of meas. value (-30 to 0°C) ±1°C (-20 to +100°C) ±2°C or ±2% of meas. value (remaining range) 0.5°C -20 to + 50°C -40 to +70°C 200 g 9V PP3 battery

Testo 830-T3: Resolution: Operating Temperature: Storage Temperature: Weight: Battery type: Type

testo testo testo testo

3

830-T1 830-T2 830-T2 Set 830-T3

Measuring range °C -30 to 400 -30 to 400 -30 bis 400°C -25 to 400

PK

1 1 1 1

Cat. No.

9.718 9.718 9.718 9.718

413 414 417 416

3 Digital thermometers, Scantemp ST series Infra-red thermometers with laser sighting. This handheld, infra-red thermometer enables the simple and rapid measurement of temperatures without contact with the measured object. Very simple to operate. Particular features include short measuring times (0.5 sec.) and convenient measuring from long distance. Allows measurement of difficult to reach or potentially dangerous instruments, e.g. high-voltage machinery. With memory storage of Max., Min. and Average values. ST60/ST80 additionally offer a visual and acoustic alarm when set limits are exceeded, 12 measurement memory and contact sensor probe connection. ProScan 520: incl. thermocouple sensor type K, USB interface and Windows software. Accuracy: Reproducibility: Time: Spectral sensitivity: Display resolution: Working temperature range: Voltage supply: Dimensions L x W x H: Weight: Dot laser Type

ProScan 510 ProScan 520

Temp. range °C -32°C to 530°C -32°C to 760°C

±1.0% of measured value or ±1°C, larger value applies ±0.5% of measured value or ±1°C, larger value applies 300ms 8 to 14µm 0.1°C (4-digit LCD) 0 to 50°C 9 V PP3 battery 190 x 38 x 45mm 500g (incl. packaging) Emissivity

Optical resolution

0.100 to 1.000 0.100 to 1.500

20 : 1 40 : 1

PK

Cat. No.

1 1

9.851 928 9.851 929

PK

Cat. No.

1

9.718 409

Protective leather case for Infra-red thermometer testo 830-T1/-T2/-T3 Testo Description Protective case, incl. belt holder

326

E & OE.


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Contact, Insertion themometers-Temperature meters 1 Resistance glass covered temperature sensor Pt100 To DIN EN 60751, class A tolerance. Pt100 Glass temperature sensor Temperature range: Measuring resistance: Protective covering: External diameter: Connection: Coupling: Type

Single Pt100 Single Pt100 Single Pt100 Single Pt100 Single Pt100 Double Pt100 Double Pt100 Double Pt100 Double Pt100 Double Pt100

1 Buddeberg

- 30°C to + 350°C M-FK 422.4 (Heraeus) 3.3 borosilicate glass 8mm 4-wire Lemo Grade 1.

Immersion length mm 100 200 300 400 500 100 200 300 400 500

PK

1 1 1 1 1 1 1 1 1 1

Cat. No.

9.774 9.774 9.774 9.774 9.774 9.774 9.774 9.774 9.774 9.774

800 801 802 803 804 805 806 807 808 809

Alternative designs are available - details on request !

2 Thermometer Pocket-Digitemp

2

Waterproof instrument in plastic housing (food-grade). Low budget, durable instrument for measuring temperature in air, gas, liquid and platical substances. Range of applications: Food (HACCP), industry, agriculture and hobby. Features: waterproof, 1-second measuring frequency, Max-Min-Hold function, °C/°F-selectable.

Sensor: Measuring range: Resolution: Accurancy: Dimensions: Probe dimensions: Weight:

NTC -40°C to +200°C 0.1°C ±0.8°C (at 0°C to 100°C) others 1.5°C 202 x 20 x 16 mm (long version) 75 x 3.5 mm (short version) 150 x 20 x 16 mm (short version) 126 x 3.5 mm (long version) 40 g

Type short version long version

PK

Cat. No.

1 1

9.851 028 9.851 029

3 Digital thermometer ama-digit ad 14 th

3

Range: -35 to +500°C, resolution 1°C. Rapid response and ergonomic design. Dimensions (WxDxH) 90 x 60 x 25 mm. With stainless steel probe (L x dia.) approx. 100 x 2.5 mm. With battery.

Amarell

Type ama-digit ad 14 th

E & OE.

PK

Cat. No.

1

9.243 100

327


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Temperature meters 1

1 Digital thermometer ama-digit ad 15 th Range: -40 to +120°C, resolution 0.1°C. Precise and cost-effective. Dimensions (WxDxH) 90 x 60 x 25 mm. With stainless steel probe approx. 30 x 2.5 mm (L x dia). With battery. Available in red, blue, green, yellow and black. Please state colour when ordering. Type ama-digit ad 15 th

2

PK

Cat. No.

1

9.243 101

2 Digital thermometer α∝α−διγιτ αδ 20 τη Range: -50 to +300°C. resolution 0.1°C from -50 to +180°C, 1°C for the rest of the range. Dimensions (WxDxH) 90 x 60 x 25 mm. With battery. For appropriate temperature probes see order no. 9.243 111 to 114 Type ama-digit ad 20 th

3

Amarell

PK

Cat. No.

1

9.243 102

3 Temperature probes, Pt 100 for ama-digit ad 20 th Class A. Stainless steel sheathed probe, approx. 105 x 3mm L x dia. With handle and approx. 1m cable. Type Pt100 Pt100 Pt100 Pt100

4

Amarell

PK immersion probe penetration probe surface probe air probe

1 1 1 1

Cat. No. 9.243 9.243 9.243 9.243

111 112 113 114

4 Digital thermometers ama-digit ad 30 th/31 th Range: -40 to +150°C, resolution 0.1°C. Proven and precise. Dimensions (WxDxH) Amarell 115 x 65 x 26 mm. With stainless steel probe 100 x 2.5 mm (L x dia.) and surface measuring tip. Hold function. With battery. Type 31 th additionally has an analogue recorder output.

Type ama-digit ad 30 th ama-digit ad 31 th

5

PK

Cat. No.

1 1

9.243 103 9.243 105

5 Precision thermometer Precisa -ad 3000 th Digital precision thermometer, measuring range -20 to +150°C, resolution 0.001°C. With Max./Min. memory storage. For heavy-duty applications. Excellent reproducibility, long term stability. Optional accessories: - RS 232 serial interface - software - 9V power supply adapter - measuring range: up to +200°C Reproducibility: ±0.01°C up to +100°C, ±0.1°C rest of range Temperature Probe: Pt 1000 Battery: 9V, 6F22 Housing (WxDxH): 150 x 80 x 32 mm Type ad 3000 th

328

E & OE.

Amarell

PK

Cat. No.

1

9.243 110


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Temperature meters 1 High Precision Thermometer Physics 1000

1

The Physics 1000 high precision digital thermometer provides excellent resolution, Schneider precision and linearity for mains-independent, temperature measurements in quality assurance, process monitoring and product control applications. Primary work areas of Physics 1000 are within the chemical and pharmaceutical industries, food industry, as well as research and development. -

1 output channel for digital interfaces high resolution A/D converter. 24bit, 2.5 Mbit/s easy operation via 4 soft keys and cursor measuring menu: 2 values and difference indication measuring functions: zero setting, hold multipoint calibration for highest accuracy functions: max/min value, 100 result memory sensor programming: dimension, resolution, hold, comment device configuration: device designation, display contrast and illumination time, baud rate language selection: german, english, french DKD Calibraton Certificate optional

Specifications Measuring inputs: Galv. disconnect.: Sensor function: Range: Resolution: Self calibration: Accuracy: Temperature drift: Temperature units: Output: Display: Display illumination: Memory intern: Battery operation: Current consumption without illumination: with illumination: Mains adapter: Dimensions (L x W x H): Weight housing: Material housing: Protection class, DIN EN 60529: Type

Physics 1000 Resistance thermometer WT-GL-303-3/6* Resistance thermometer WT-MI-303-D-30E*

2 input channels Semiconductor relay (50V) Pt100 (current of probe: 1mA) -200°C to +400°C 0.001K/0.01K Zero point, measuring current 0.01% v.Value ±3 digit 0.003 %/°C °C, °F, K 1 plug for interface cable 128 x 64 pixel, 8 lines 2 white LED´s 100 values 3 x 1.5V AA Alkaline 20mA 40mA 230V a.c./12V d.c., 200mA /40mA 127 x 83 x 42mm 290g ABS (max. 70°C) IP54 Shaft diameter

Temp. range °C

glass, diam. 6 mm, recessed metal, diam. 3 mm, continuous

-50 to +310 -90 to +410

PK

Cat. No.

1 1 1

9.908 040 9.908 041 9.908 042

*Pt100 to DIN EN 60751 class A, 4-Leiterschaltung

2 Temperature meter, digital, testo 922/925

2

Without probe. With battery and calibration protocol. For °C, °F, °K. Hold function and battery display.

Testo

Model testo 925. Economical. Very robust. with 1 measuring input. Also available with IR probe for contact-free measurement on request.

Measuring range: Sensor: Accuracy: Battery:

-50 to +1000°C Type K (NiCr-Ni) -40 to +900°C : ±0.5°C, ±0.3 % otherwise: ±0.7°C, 0.5 % 9V, 6F22

Type testo 925 testo 922

E & OE.

PK

Cat. No.

1 1

9.851 324 9.851 325

329


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Temperature meters 1 Thermometer H370

1

Perfectly designed instrument for measurements according to HACCP rules. The instrument is very robust and watertight (IP65). The probe included is exchangeable and the connection is very strong (screwthreaded connector). Supplied with a traceable calibration certificate. Especially suitable for direct measurement of materials.

Specifications Measuring range: Resolution: Accuracy: Display: Housing: Dimensions: Weight: Batteries:

-100 to +300°C 0.1°C ±0.4°Χ (−30 το 15°Χ), οτηερωισε ±0.6°Χ +0.1% ∝εασυρινγ ρανγε 2-line LCD, 7 segments ABS plastic 150 x 66 x 31mm 350g 3 x 1.5V AAA

Type

PK

Cat. No.

H370

1

6.235 813

2 3 4 5 6 Digital thermometers, testo 925 /922, accessory probes Waterproof immersion/penetration probe (a) Precise, watertight food probe, stainless steel, resistant to cleaning by aggressive materials and oven-proof up to 205°C (b) Precise and rapid, waterproof immersion probe (c) Rapid reaction surface probe (d) Robust food penetration probe with special handle Robust, economical, air probe (e) Description Immersion / penetration probe Stainless steel food probe Immersion probe Surface probe Penetration food probe Air probe

Figure

PK

a b c d e

1 1 1 1 1 1

3

2

-a-

Testo

4

-b-

9.718 9.718 9.718 9.718 9.718 9.718

200 201 202 222 203 230

6

5

-c-

Cat. No.

-d-

-e-

Accessories for temperture meters testo 925/922 Testo Type

For

TopSafe testo 925 TopSafe testo 922

protective cover against impact and dust protective cover against impact and dust

330

E & OE.

PK

Cat. No.

1 1

9.718 011 9.718 020


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Temperature meters 1 2 Digital thermometers testo 110/112 For use with accessory NTC sensor probes. For control measurements in the food industry and laboratories. Features: switchable °C, °F readout, with Hold function, low battery indicator and battery saving automatic switch-off after a period without use. With battery and calibration certificate. Accuracy testo 110: System accuracy using immersion/penetration probes. -25 to +75°C : ±0.4°C, +100 to +150°C : ±1 % Meas. value., ±0.8°C: rest of range Model testo 112: Suitable for verification use between -25 to +120°C. Accuracy in accordance with notified requirements, with internal temperature monitoring.

Battery: Type

testo 110 testo 112

Testo

9V, 6F22 Measuring range °C -50 to +150 -25 to +120

1

PK

Cat. No.

1 1

9.851 300 9.851 299

2

9.851 299

9.851 300

We can supply this

manufactorer’s whole product range ! E & OE.

331


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Temperature meters 1 2 3 4 5 Digital thermometers testo 110/112, accessories Testo Type

For

Dia.

TopSafe (IP68 protective boot)

testo 110

mm 0

TopSafe (IP68 protective boot)

testo 112

0

NTC immersion/penetration probe

testo 110

4

NTC laboratory probe, glass sheathed NTC surface probe, with widened measuring tIP NTC air probe, robust

testo 110

PK

Cat. No.

1

9.718 020

1

9.718 011

110 -50 to +150

1

9.851 716

6

200 -50 to +150

1

9.851 717

testo 110

5

115 -50 to +150

1

9.851 720

testo 110

5

115 -50 to +150

1

9.851 723

NTC food probe, appropriate for verification NTC immersion/penetration probe, appropriate for verification

testo 112

4

124 -25 to +125

1

9.851 315

testo 112

5

115 -25 to +125

1

9.851 348

NTC air probe, appropriate for verification

testo 112

5

115 -25 to +125

1

9.851 349

Robust food penetration probe with special handle

testo 110

5

115 -25 to +120

1

9.851 352

2

1

9.851 315

332

0 -

5

4

3

9.851 349

Length Measuring range mm 째C 0 -

9.851 716

E & OE.

9.851 723

9.851 720


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Temperature logger 1 Temperature logger Temperature recording and memory system Specifications Measuring ranges, internal sensor: External sensor: LCD readout function: Measurement accuracies, standard unit: Unit with external sensor: Resolution: Memory: Measuring interval: Measuring mode: Dimensions: Temperature sensor: Battery: With calibration certificate.

Type

Description

EBI-2T-112

1 ebro -40 to + 75°C -50 to + 150°C (400°C) -20 to + 50°C ±0.2°C ±1 Digit ±0.4°C ±1 Digit 0.1°C up to 40000 values Selectable from 1 sec. to 8 hrs. continuous or intermittent 96 x 48 x 28mm Pt1000 Lithium, 3.6V

PK

Cat. No.

Temperature logger with internal sensor

1

9.908 103

EBI-2T-311

Temperature logger with external sensor

1

9.908 104

EBI-FUE-T-1.0

External Pt1000 sensor probe, cable length 1 metre.

1

9.908 105

EBI-KSY-RS-232 EBI-WINLOG-2000S EBI-2T-321

1 1 1

9.908 109 9.908 110 9.908 049

EBI-FUE-T100-2,5M-L

RS232 interface Data retrieval software Temperature logger with external sensor probe with Lemo connector

1

9.908 050

EBI-FUE-T100-2,5M

probe without Lemo connector

1

9.908 051

EBI-2T-331

Temperature logger with external sensor probe Pt 1000 with Lemo connector probe Pt 1000 without Lemo connector

1

9.908 052

1

9.908 053

1

9.908 054

EBI-FUE-T200-L Pt EBI-FUE-T200-2,5M

2 Temperature data logger, EBI series

2

Designed for temperature and pressure measurement when heat treating food and ebro pharmaceutical products. For monitoring the sterilization of autoclaves, store rooms, blood banks, etc. The loggers are individually programmed via an accessory external interface, then placed at the test location and subsequently readings are downloaded and read via the interface. Range, Temperature: Range, Pressure: Accuracy, Temperature: Accuracy, Pressure: Temperature sensor: Resolution, Temperature: Resolution, Pressure: Battery: Housing: Protection level: Calibration certificate

0 to +150^C 1 to 4000mbar 0.3°C 20mbar Pt1000 0.1°C 1mbar 3.5V Stainless steel, (V4A), PEEK, IP68

Type

Description

EBI 100-T100 EBI 100-T230 EBI 100-TP230

-40 to +150°C -40 to +150°C, axial sensor 0°C to + 150°C,1mbar to 4000mbar

E & OE.

PK

Cat. No.

1 1 1

9.908 087 9.908 088 9.908 089

333


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Temperature logger 1 Accessories for temperature data logger, EBI series 85 - 125 A

1

ebro Type

Description

EBI IF 200

4-point Interface for EBI 100

PK

Cat. No.

1

9.908 090

2 3 4 Data Logger EBI-20 T/EBI-20 TH/EBI-20-TE/EBI 20-THP

2

Applications: - reliable temperature and temperature/humidity recording - transport - storage monitoring - refrigeration areas and coldrooms Features: - excellent price/performance ratio - waterproof - visual Alarm - Max/Min values on display - replaceable battery Specifications Measuring range temperature: Measuring range humidity: Accuracy, temperature: Accuracy, humidity: Resolution temperature: Resolution humidity: Memory: Sensor: Operating temperature: Storage temperature: Measuring period: Measuring mode:

3

Battery: Battery life: Protection class: Housing : Dimensions: Weight:

4

Type

Description

EBI-20 T EBI-20 TH EBI-20 T-Set EBI-20 TH-Set

EBI-20-TE EBI 20-THP EBI-20 AUF

334

ebro

-30 to +60°C 0% to 100% R.H. ±0.5°C (-20 to +40°C); ±0.8°C for remaining measuring range ±3% R.H. (10 to 90% R.H.) 0.1°C 0.1% R.H. 8000 measured values NTC for temperature/capacitive for humidity -30 to +60°C -40 to +60°C 1 minute to 24 hours immediate loop measurement, measurement from starting point, start immediately until memory full, start/stop measuring, start when button pressed 3V lithium, replaceable At least 2 years (at 15min measuring rate @ 25°C) IP 67 (EBI-20 T); IP 52 (EBI-20TH) ABS 69 x 48 x 22mm approx. 45g

PK

Cat. No.

Temperature Logger Temperature Humidity Logger Starter-Set (Temperature Logger, evaluation software, Interface) Starter-Set (Temperature Humidity Logger, evaluation software, Interface)

1 1 1

9.908 069 9.908 070 9.908 073

1

9.908 074

Temperature Logger Temperature, Humidity, Pressure Data Logger Wall mounting

1 1 1

6.228 382 9.908 055 9.908 079

E & OE.


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Temperature logger 1 Data Logger EBI-20 T/EBI-20 TH Starter-Set SL 1100 for routine checks The set contains: 1 x temperature logger EBI 10-TP 230 1 x silicone protection box AL 101 1 x interface EBI IF 100 1 x Winlog.med validation software 1 x carrying case Specifications Measuring range, temperature: Measuring range, pressure: Accuracy temperature: Accuracy pressure: Sensor: Operating pressure Memory: Type

Description

SL 1100 EBI 10-TP230

1 ebro

-40 to +150°C 1 mbar to 3500mbar ±0.1°C (0 to +140°C) ±0.2°C (140 to +150°C) ±15 mbar 1 Temperature, external, axial 7 bar 27000 readings PK

Cat. No.

Starter Set (Temperature and pressure)

1

9.908 046

Temperature logger

1

9.908 091

2 Accessories for data logger EBI-6

2 ebro

Type

Description

EBI 6-KOF

Case for max. 10 data loggers & accessories External sensor RS232 interface

EBI-6-FUE EBI 6-RS232

PK

Cat. No.

1

9.908 082

1 1

9.908 083 9.908 084

3 Temperature data loggers, mini , testo 175 H2

3

2 channel humidity/temperature logger with internal sensors, wall mount and calibration protocol. Reliabe monitoring of humidity/temperature ranges in industrial processes, in stores and museums.

Testo

Accesories as testo 175-T2 ! Technical Data: Measurement: Probe: Measuring channels: Measuring range: Resolution: Accuracy system: Internal: ±1 Digit Store: Operating temperature: Storage temperature: Weight: Protection rate:

Humidity/Temperature Humidity probe /NTC (internal) 2-channel (internal %R.H.;°C) 0 to 100 %R.H. -20°C to +70°C 0.1%R.H./0.1°C ±0.3%R.H. ±0.5°C 16000 Measurements -20°C to +70°C -40°C to +85°C 85g IP68

Type testo testo testo testo

PK 175-H2 175-H2 with calibration certificate 0520 0151 175-H2 with calibration certificate 0520 0076 175-H2 with calibration certificate 0520 0076 + temperature calibration certificate 0520 0221

1 1 1 1

Cat. No. 6.802 6.222 7.400 6.902

095 161 893 378

Certificate of calibration on request available

E & OE.

335


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Temperature logger 1 Polymeter

1

On polished wood mount. Lacqered finish. Combined with thermometer for determining relative humidity, temperature and dew point, saturation deficit, pressure and absolute humidity. Measuring ranges: Face dia.:

Thies

0 to 100% R.H. -30 to +50°C in 1° divsions 80 mm

Type Polymeter

PK

Cat. No.

1

9.125 505

2 Thermometers, digital, professional level, TFX-430 series Applications: - temperature monitoring - laboratory - air, liquids, plastic masses - aggressive media, surfaces - process monitoring - reference measurement Features: - high accuracy - four-wire measuring system - waterproof IP67 - approx. 5 years battery life - factory calibration certificate - different probes for different applications

2

Specifications Measuring range: Accuracy:

Resolution:

Operating temperature: Storage temperature: Probes: Measurement interval: Battery: Switch-off: Dimensions: Weight: Protection class: Housing material: Type

Description

TFX 430 TFX 430 + TPX 130

Pt100 (without probe) Pt100, with probe (Length 130mm, 3mm dia., blunt) Pt100, with probe (Length 130mm, 3mm dia., pointed) Pt100, with probe (Length 190mm, 8mm dia., glass-coated)

TFX 430 + TPX 230 TFX 430 + TPX 330

336

ebro

-100 to +500°C without probe: ±0.1°C (from -50 to +100°C); remaining measuring range: ±0.2°C with probe: ±0.05°C (from -50 to +199.99°C); remaining measuring range: ±0.2°C without probe: 0.02°C (from -50.00 to +99.98°C); remaining measuring range: 0.1°C with probe: 0.01°C (from -100 to +199.99°C); remaining measuring range: 0.1°C -20 to +50°C -30 to +70°C Pt100 1 to 15 secs Lithium 3V, 1Ah, Type CR2477 Automatically after 2 hours 109 x 54 x 22mm approx. 90g IP67 ABS

E & OE.

PK

Cat. No.

1 1

9.908 075 9.908 076

1

9.908 077

1

9.908 078


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Thermometers/Temperature logger-Timing/Timers Temperature data loggers, mini , testo 175 series, accessories Set ComSoft 3 - Basic, Basis Software with diagrammatic and table representation, interface for logger with table mount and PC connection cable.

Testo

Printer testo 575 Set Data collector testo 580 incl. mount for logger Type Set ComSoft 3-Basic Printer testo 575 Data collector testo 580

2

1

PK

Cat. No.

1 1 1

9.718 331 9.718 332 9.718 333

3

1 Mechanical stopwatch Start/stop/reset by single crown, clockwork mechanism, 13 jewels, chrome metal case, measuring range 15 minutes, 1/10 second increments. Supplied with lanyard and soft case, 250g (incl. packaging)

Type Mechanical stopwatch

PK

Cat. No.

1

9.851 021

2 Stopwatches, mechanical Impact resistant, dustproof and water resistant. With diamond-turned metal case. 55 mm diameter. Built-in strap ring. Time intervals secs. 1 / 5 1 / 10

Display

PK

Cat. No.

mins. 30 15

1 1

9.262 005 9.262 010

3 Stopwatches, mechanical Impact resistant, dustproof, water resistant. With diamond-turned metal case. 55 mm diameter. Built-in strap ring. Time intervals secs. 1 / 5 1 / 10

Display

PK

Cat. No.

mins. 30 15

1 1

9.262 205 9.262 210

E & OE.

337


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Timing/Timers 1

1 Stopwatches, mechanical Amigo. Impact resistant. Unbreakable spring movement. 55 mm diameter ABS case. Supplied with 120 cm lanyard.

Time intervals secs. 1 / 10 1 / 5

2

Display

PK

Cat. No.

mins. 15 30

1 1

9.262 410 9.262 411

2 Stopwatch Tristop. Separate 1/10 second display magnified 10 times. Chrome-plated ABS housing with neck cord (120 cm), 7 jewel, pin lever movement. 1/5 sec. divisions. 0 to 30 minute face. Type Tristop

3

PK

Cat. No.

1

9.262 510

PK

Cat. No.

1

9.851 020

PK

Cat. No.

1

6.230 554

3 Stopwatch, hitrax run 1/100 seconds,max. 23 hours, 59 minutes, 59 seconds, split time, clock, date, alarm. Supplied with 3V Lithium long-life battery CR 2332 button cell

Type HiTrax Run

4

4 Timer SL 110 -

1/1000 sec. timer up to 40 minutes, 1 sec. timer for 40 minutes up to 24 hours lap time function time in 12/24-hour-format time, month, day, alarm snooze function splash water resistant Incl. 1 x 1.5V button cell SR44 dimensions: 69 x 59 x 19 mm weight: 51g

Type SL 110

338

E & OE.


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Timing/Timers 1 Stopclock, digital

1

Stopstar 2. ABS housing with lanyard. Temperature range -10 to +55째C. With 7-digit, 7 mm high LCD readout. Start/Stop/Reset, Cumulative (as often as required), Split interval timing (as often as required), dual measurement of two events in quick succession. Time display: 9 hrs, 59 mins, 59.99 sec. Battery life approx. 2 to 3 years. Supplied with button cell (IEC R 6). Dimensions: Weight:

82 x 61 x 28 mm 70 g

Type Stopstar 2

PK

Cat. No.

1

9.262 062

2 Stopwatch, digital

2

Profile LCD. 2 button operation, with 5 event memory, each with split and lap times, 8 mm high LCD readout, 7-figure + 2 event counter, display range: 9 hrs, 59 mins, 59.99 secs. With Start/Stop/Reset, Add./Split/Lap, time functions. Type Stopwatch, digital

PK

Cat. No.

1

9.262 111

3 Stopwatches, Delta E series

3

Delta E 100 - 65 memories with evaluation, fast run/memory functions - Large, clear, 2.5-line LCD readout with 7mm high digits - Battery status indicator - Function window for Lap, Short-Lap and time. Date indicator and pre-settable split time from the real-time clock - Mode function button - Display and memory button. Delta E 200 Generally as Delta E 100 model, but additionally with: - Pacer function (1 to 300 strokes/min.) - Countdown function - Countdown and stopwatch can be used simultaneously.

Type

Colour

Delta E 100 Delta E 100 Delta E 200

black red black

PK

Cat. No.

1 1 1

9.262 520 9.262 521 9.262 530

4 Timer

4

Compact. Countdown/Countup. Digital reading, with alarm and repeat function. 12 hr. clock function. Countdown and countup display: 23 hrs, 59 mins, 59 secs. Dimensions (WxDxH): 64 x 60 x 16 mm Weight: 40 g Type Compact

PK

Cat. No.

1

9.262 071

5 Electronic timer clock

5

Count down/count up timer with loud alarm signal at end of timed period. With Clock, Stopwatch and Memory functions. Timer up to 24 hours. Fittings: magnet, stand and clip. Dimensions (WxDxH): 68 x 53 x 20 mm, with battery. Type

E & OE.

Amarell

PK

Cat. No.

1

9.235 145

339


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Timing/Timers 1

1 Electronic Timer and Stopwatch With large display and 10-key setting. Counts up or down from 10 hours to 1 second. With pocket clip, bench stand, magnetic attachment and battery. Overall 70 x 60 x 25mm, weight 95g.

Type

2

Cat. No.

1

9.851 027

2 3-channel-timer Indispensable for laboratories. Triple timer with large display. -

Dostmann electronic

indicates three separate times simultaneously stopwatch function integrated quartz watch supplied with magnet and clip

Technical Specifications Range: Operating temperature: Power supply: Dimensions: Weight:

1 sec to 20 hours 0 to 50째C 1.5V AAA 88 x 71 x 24mm 115g

Type 3-channel-timer

3

PK

PK

Cat. No.

1

6.233 690

3 Stopwatch WB 388 Three separate timers in one instrument. Countdown/countup. Audible alarm sounds when 'zero' reached. 12/24 hour clock. Loud/soft alarm switch. Operating instructions in 3 languages. Dimensions (WxDxH): 83 x 22 x 70 mm Weight: 80 g Type WB 388

4

Cat. No.

1

9.260 184

4 Countdown timer TR 113 -

large, 4 digit, LCD readout countdown/countup 99 min., 59 sec. measuring cylinders Audible alarm sounds when 'zero' reached with pocket clip/bench stand and magnet operation manual in 5 languages with 1x 1.5V AAA battery dimensions: 73 x 66 x 18mm weight: 61g

Type

340

PK

E & OE.

Oregon Scientific

PK

Cat. No.

1

6.700 333


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Timing/Timers 1 Dual Timer TR 118 OS -

1

Large, 6 digit, LCD readout 2 separate timers in one instrument Countdown/countup 99 hrs., 59 mins., 59 secs. Clock function switch Audible alarm sounds when 'zero' reached With pocket clip/bench stand and magnet Operating instructions in 3 languages. Supplied with 'AAA' 1.5 V battery

Dimensions (WxDxH): Weight:

73 x 66 x 18 mm 63 g

Type TR 118 OS

PK

Cat. No.

1

9.260 186

2 Digi-Clock timer, TR 119 OS -

2

Large, 6-digit LCD display Programmable for up to 23 hrs, 59 mins, 59 secs. 1-minute audible alarm when timed period has expired Countdown or countup functions Time display Case incorporates combined bench stand/pocket clip with magnet. With instructions in 3 languages

Supplied with 1 x 1.5 V AAA battery. Dimensions (WxDxH): 73 x 70 x 19 mm Weight: 50 g Type TR 119 OS

PK

Cat. No.

1

9.260 189

3 Microchronometer, TR 112 OS -

3

4-figure LCD time readout for minutes and seconds Programmable for up to 99 mins, 59 secs. 30-second audible alarm when timed period has expired Countdown Timer memory function Case incorporates combined bench stand/pocket clip with magnet. With instructions in 3 languages Supplied with 1 x 1.5 V AAA battery.

Dimensions (WxDxH): Weight:

66 x 56 x 18 mm 45 g

Type TR 112 OS

PK

Cat. No.

1

9.260 181

4 4 Short period timer KT 188. Countdown timer from max. 99 mins., 59 secs. A 30 Sec. loud audible alarm sounds when 'zero' reached. With magnet. Operating instructions in 3 languages. Supplied with 'SR 44' 1.5 V button cell.

Dimensions (WxDxH): Weight:

88 x 12 x 46 mm 30 g

Type Short period timer

E & OE.

PK

Cat. No.

1

9.260 188

341


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Timing/Timers-Clocks 1 Microchronometer with clock Easy to operate. Quartz-accurate. With electronic alarm signal. Adjustable from 1 sec. to 24 hrs. Memory. Dimensions (WxDxH): 80 x 45 x 85 mm Weight: 120 g Type Microchronometer with clock

1

PK

Cat. No.

1

9.260 187

2

2 Interval timer with alarm Benchtop mechanical timer. Suitable for standing or hanging. Casing and rotary setting knob are white, the dial is black. Running time max. 60 mins. Dimensions (WxDxH):

65 x 35 x 65 mm

Type Interval timer with alarm

3

PK

Cat. No.

1

9.260 020

3 Stopclock, analogue, Mesotron Quartz-accurate timer with large, analogue display. Measuring range: 0 to 60 secs, 0 to 60 mins. Inner scale 1 to 100 secs/100 mins. 110 mm dia. dial. Battery life over 18 months with a 1.5 V button cell. Dimensions (WxDxH): 130 x 40/95 x 175 mm Weight: 375 g Type Mesotron stopclock

4

PK

Cat. No.

1

9.262 080

PK

Cat. No.

1 1

9.260 178 9.260 179

4 Benchtop timers, countdown/countup, Prisma series Prisma 200. - ABS plastic case - Large, easy to read LCD display - Stopwatch function - Normal time display - Selectable time resolution 999mins., 59 secs. or 9 hrs., 59 mins., 59 secs., 1/10 sec. - Loud audible alarm - 2 channels with start/stop operation, either separately or together. Prisma 400. Generally as Prisma 200, but additionally with: - Sequence programming - Function window - 4 channels.

342

Type

Colour

Prisma 200 Prisma 400

white white E & OE.


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Timing/Clocks 1 Radio alarm clock RM 912 TC grey OS -

1

Time adjustment and synchronization via radio signal DCF-77 for Central European time zones only With 24 hour display with hh: mm: ss Date display: day/month Weekday display in choice of 4 languages Second time zone function Time and date manually adjustable Radio signal strength display in 3 stages Backlighting by pressing on the snooze button (5 sec.) and during the alarm (5 sec.) Alarm function Snooze function (8 mins.) 2-minute crescendo alarm Easy adjustment "24 h Alarm off" and "Permanent On/Off" Two independent alarm times can be set Battery change display Supplied with 2 x 1.5 V 'AAA' batteries.

Dimensions (WxDxH): Weight:

85 x 47 x 107 mm 160 g

2 Radio controlled wall clock -

2

Highest precision radio-controlled clock Analogue display with second hand Digital display of date Large dial Ideal for home, office, waiting room, lobby or entrance hall and as a gift Ø 300 mm Battery included 1.5 V AA

Type Radio controlled wall clock

PK

Cat. No.

1

9.851 019

3 Time switches

3

With earthed plug. Timer 26 - Daily programme adjustable in 15 min. segments Eltimo 020 S - Switch-on intervals: 10 to 120 min. - Switching capacity 3500 W

Theben

Type Timer 26 Eltimo 020 S

PK

Cat. No.

1 1

9.000 030 9.000 031

4 Electronic timer UTI 1

4

UTI 1 electronic long duration timer. Ideal for automatically switching off devices after long processes, such as e.g. an extraction. Times from 0.1 to 999.9 min adjustable in steps of 6 sec. ”Locking function“ against accidental changes to the settings. Specifications External dimensions (W x H x D) Voltage Switching capacity Connection of the devices Time-setting range Type

Description

UTI 1

Electronic timer

Behr

approx. 14.5 x 9.5 x 20.5cm with fold-out foot approx. 14.0 x 12.5 x 20.5cm 220V 50Hz, max. 2200W max. 2.2 kVA at 230V a.c. via mains plug on the rear of the UTI 1 0.1 - 999.9 min, digitally adjustable in steps of 6 sec.

E & OE.

PK

Cat. No.

1

9.882 112

343


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Climate measurement/Hygrometer 1

1 Thermohygrometer, analogue Synthetic hair, spun metal case with dial and brass hanging ring. Measuring range Relative humidity: 0 to 100% Temperature: -15 to 55°C Wieght: 105g Dia. mm 100

2

PK

Cat. No.

1

9.726 403

PK

Cat. No.

1

9.726 404

2 Thermohygrometer, "Climatherm" Spun metal case with dial, separate humidity and temperature indicators, and brass hanging ring. Measuring range Relative humidity: 15 to 100% Temperature: 0 to 40°C Weight: 90g Dia. mm 100

3

3 Thermohygrometer Universal application thermohygrometer with outdoor probe and stand/attachment device. Accessory wall mounting (screws or adhesive tape) are available on request. Specifications Measuring range: Dimensions (WxDxH):

0 to 50 x 0.1°C 20 to 99 x 1% R.H. approx. 65 x 20 x 97mm

Type Thermohygrometer

4

Amarell

PK

Cat. No.

1

9.235 135

PK

Cat. No.

1

9.726 405

4 Thermohygrometer TA 100 - very fast humidity sensor - dewpoint and max./min. function - °C/°F-switchable - Hi-Lo alarm with red warning LED Specifications Temperature Measuring range: -40 to +70°C Display resolution: 0.1°C Accuracy: ±0.5°C (0 to 60°C) remaining range ±1°C Humidity Measuring range: 0 to 99% R.H. Display resolution: 0.1% Accuracy: ±5% (20 to 80%) Working temperature: -40 to +70°C Batteries: 2 x 1.5 Volt AAA Dimensions: 105 x 105 x 44mm Weight: 150g (incl. packaging) Type TA100 thermohygrometer

344

E & OE.


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Climate measurement/Hygrometer 1 Thermohygrometers, testo 608-H1/-H2

1

The standard testo 608-H1 hygrometer continuously measures humidity, temperaure and dew point. The testo 608-H2 precision alarm-hygrometer includes an LED alarm lamp, indicating the set point has been reached.

Testo

- With dew point calculation td and max/min display - Humidity sensor is not affected by condensation - Battery monitor (batteries included)

Specifications: Temperature: Measuring range: Accuracy (±1 Digit): Resolution: Humidity Measuring range: Accuracy (±1 Digit): Resolution: Dewpoint Measuring range: Operating temperature: Storage temperature: Dimensions (WxDxH): Weight:

testo 608-H1/testo 608-H2 0 to +50°C/0 to +70°C ±0.5°C (at +25°C) 0.1°C +10 to +95%R.H./+10 to +98%R.H. ±3%R.H./±2%R.H. 0.1%R.H. -20 to +50°C td/-40 to +70°C td 0 to +50°C/-10 to +70°C -40 to +70°C 120 x 40 x 89 mm 168 g

Type testo 608-H1 testo 608-H2

PK

Cat. No.

1 1

9.726 964 9.726 965

We can supply this

manufactorer’s whole product range ! E & OE.

345


3. Analytical measurement and testing Climate measurement/Hygrometer 1 2 Precision handheld instruments P600 series For temperature, moisture and airflow. For highly accurate temperature measurements with RS232 PC online interface. (Optional: Windows SmartGraph software for graphical and tabular documentation, etc). Integral probe calibration for sensor tolerance compensation. Min.- Max.- Hold- and AVG- functions. The large LCD shows two measurements synchronously, even temperature differences can be displayed ( P605, P655, P670). P600/P615: high-quality thermocouple probe instruments (-200 to +1370°C) P610/P605: The all-rounders, with a wide temperature range for Pt100 and thermocouple probes (-200 to +1730°C) P650/P655: highly accurate reference instruments for a variety of parameters (±0.03°C), temperature, moisture, thaw point and flow. Specifications General (all models): RS232 interface, Max-Min memory, Hold function, true average calculation over a freely selectable period, Auto-off function, measured quantities can be freely assigned to instrument channels, comprehensive calibration options (selectable 1-point, 2-point or 3-point calibration), large display with bar graph for simultaneous display of 2 measured values P600/P605 1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S) measurement ranges and accuracies: Pt100:-200 to +850°C ( ±0.1°C -100 to +200°C, otherwise ±0.1% of measurement value) thermocouples, DIN types (-200 to +1760°C) P650/P655 1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S, moisture, flow) measurement ranges and accuracies: Pt100: -200 to +850°C (±0.03°C -50 to +200°C, ±0.05°C -200 to +200°C, otherwise ±0.05% of measurement value) thermocouples, DIN type (types J, K, L, N, T 0 to 200°C, ±0.3°C, +200 to +1000°C ±1.0°C, otherwise ±.5°C; type R, S ±1.0°C +0.1% of measurement value) humidity 0 to 100% R.H. ( ±0.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value +1.0% of final value) P670 2 measurement channels (Pt100, thermocouples type J, K, L, N, T, R, S, moisture, flow) measurement ranges and accuracies: Pt100: -200 to +850°C ( ±0.1°C -100 to +200°C, otherwise ±0.1% of measurement value) thermocouples, DIN types, humidity 0 to 100%R.H. ( ±0.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value) Dimensions (L x W x D)/ weight: 200 x 85 x 40 mm/300 g

1

346

2

E & OE.

GENERAL CATALOGUE 2010/11


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Climate measurement/Hygrometer Type

Description

PK

Cat. No.

P610

1 channel, thermocouples type K, L, N, T

1

9.851 993

P615

2 channel, thermocouples type K, L, N, T

1

9.851 994

P600

1 channel, Pt100, thermocouples J, K, L, N, T, R, S 2 channel, Pt100, thermocouples J, K, L, N, T, R, S

1

9.851 971

1

9.851 972

1 channel, Pt100, thermocouples, moisture, dew point, flow 2 channel, Pt100, thermocouples, moisture, dew point, flow 1 channel, Pt100, explosion-proof to ATEX II 2 G EEX ib IIB T4

1

9.851 973

1

9.851 974

1

9.851 976

P655X

2 channel, Pt100, explosion-proof to ATEX II 2 G EEX ib IIB T4

1

9.851 977

P670

2 channel, Pt100, thermocouples, moisture, dew point, flow

1

9.851 975

PK

Cat. No.

P605

P650 P655 P600X

1 2 3 Accessories for hand-held meters Description Immersion probe Pt100, -50 to +350°C, Cl. B, 150x3mm Immersion probe Pt100, -50 to +350°C, Cl. B, 300x3mm Immersion probe Pt100, -200 to +450°C, ±0.03°C, 150x3mm Immersion probe Pt100, -200 to +450°C, ±0.03°C, 300x3mm Insertion probe Pt100, -200 to +500°C, Cl. B, 150x4mm Immersion probe NiCr-Ni/Type K, -40°C to +1100°C, Cl. 1, 300x1.5mm Surface probe NiCr-Ni/Type K, T90 3 sec., max. +400°C, 120x6mm

1 1 1 1 1 1 1

9.851 9.851 9.851 9.851 9.851 9.851 9.851

935 936 937 938 948 949 957

Temp. / relative Humidity -40 to 80°C / 0 to 100%, 120x20mm Airflow Turbine probe 0 to 20m/s, diam. 22 x 28mm, 150mm lg. Software DE-Graph for 95 / 98 / 2000 / NT / Vista PC-Cable, RS232 USB-RS232-adapter Powerpack 230V a.c. Service case suitable up to 3 probes & accessories

1 1 1 1 1 1 1

9.851 9.851 9.851 9.851 9.851 9.851 9.851

954 955 925 926 958 927 924

1

2

9.851 957

3

9.851 954

9.851 955

5 Temperature and moisture logger, EBI-2-TH-611

5

Designed for measuring the relative humidity and temperature of air and gases. ebro The impulse measurement procedure combined with capacitive moisture sensors ensure a long battery operating life of approx. 5 to 8 years. The dew point can be determined by simultaneously measuring moisture and temperature. With works calibration certificate. Functions: dew point, calibration, data logger memory 2 x 30000 data points. Measuring ranges: 0 to 100% R.H., 10 to +75°C Resolution: 0.1% R.H., 0.1°C Accuracy: ±2 % R.H. (for 2 to 98% R.H.), ±0.3°C Display: 9.5 mm digit LCD Battery: 3.6V Lithium Probe cable: 1.5m long Dimensions(HxBxT): 96 x 48 x 28 mm

Type

Description

EBI-2-TH-611 EBI-WINLOG-2000S EBI-KSY-RS-232

Temperature and humidity logger Standard-Software Interface

E & OE.

PK

Cat. No.

1 1 1

9.908 111 9.908 110 9.908 109

347


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Climate measurement/Hygrometer 1 2 3 LOG32 Temperature/Humidity logger -

Can store up to 32000 measurements (16000 per sensor) Freely selectable measuring intervals from 2 seconds up to 24 hours battery life time approx. 2 years status indication using 2 x LED lamps built-in USB interface WindowsTM-compatible software (german/english/french) included wall mounting

Applications: Offers the best solution to record ambient humidity and temperature data of transport containers, storage, laboratory, production plant, greenhouses etc. - quality control in laboratory, production or warehouse facilities - monitoring warehouse and cooled transport according to HACCP - ambient temp in power plants - monitoring medical refrigeration equipment

1 2

Specifications Temperature Measuring range: Accuracy: Precision: Humidity Measuring range: Resolution: Accuracy: Housing: Battery: Dimensions: Weight:

-40 to +70°C 0.1°C ±1.0°C (-20 to +50°C), otherwise ±2.0°C 0 to 100%rH 0.1% R.H. ±3%Ρ.Η. Plastic (ABS) 1 x 3.6V ½ AA Lithium 130 x 30 x 25mm 117g (incl. packaging)

Type LOG32

3

PK

Cat. No.

1

9.726 407

4 CO2 Meter, Air CO2ntrol 3000 -

Large display Measuring range: 0 to 3000ppm Incl. Power supply for 230 VAC 24-hour data logger Adjustable Alarm C°/°F-selectable Relay output for ventilation control

Applications: Ideal for monitoring the environment (CO2 concentration) in public buildings, such as universities,schools - Hospitals - Education - Office - Production plants - Public Facilities Specifications CO2 Range: Resolution:

0 up to 3000 ppm 1 ppm (0 up to 1000 ppm); 5ppm (1000 up to 2000 ppm); 10 ppm (<2000 ppm) 50 ppm or 5%, larger value applies

Accuracy: Temperature Range: Resolution: Accuracy: Display: Housing: Supply requirements: Dimensions: Weight:

0 up to +50°C 0.1°C ±1% or 1°C, larger value applies 7 segment LCD(twin-lined) Plastic (ABS) 230 VAC adapter or 4 x AA Batteries 165 x 80 x 23 mm 600 g (incl. packaging)

Type Air CO2ntrol 3000

348

E & OE.

PK

Cat. No.

1

9.726 408


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Climate measurement/Hygrometer 1 Aspiration psychrometer

1

Portable, robust and handy standard measuring instrument for psychrometric measurement of air humidity. Suitable as reference device. Measuring range: Increments: Aspirator: Dimensions (Ø x H):

Thies

-10 to +60°C 0.2°C Spring motor 90 x 420 mm

Type Aspiration psychrometer

PK

Cat. No.

1

9.726 525

2 Hygrothermographs

2

White plastic-coated metal casing, with high quality bimetallic temperature measuring system. Spring movement type: Measuring range: 0 to +40°C 0 to 100 % R.H. Dimensions(HxTxB): 280 x 140 x 260 mm Recording: 7 days/24 hrs selectable Humidity measuring element: "K" Quartz clock type: Measuring range: -10 to +50°C/10 to 100 % R.H. Operation period: 1, 7 and 31 days selectable Other measuring ranges are available on request. Type Spring clock Quartz clock Quartz clock, with plastic hood

Thies

PK

Cat. No.

1 1 1

9.726 560 9.726 531 9.726 533

4

E & OE.

349


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Climate measurement/Special climate meters 1 2 3 4 Weather station with photo viewer, "Image“

2

- 7" colour monitor with weather icons, graphics and texts, photo viewer with slide show TFA Dostmann mode - IR remote control, transmission of outdoor temperature and humidity via up to 5 transmitters (868 MHz., max. 30m) - indoor temperature and humidity indication, max./min. function - weather forecast with symbols, atmospheric pressure and tendency, bar graph indication and history of the last 24 hours - radio-controlled clock with alarm and date, indication of sun and moon position and moon phase - °C/°F selectable - bench or wall mounting

1

Supplied with: Outdoor temperature and humidity transmitter, with 2 x 1.5 V AAA batteries, IR remote control with CR2025 button cell battery, power adapter, USB cable, stand and 3 x 1.5 V AAA back-up batteries for display station.

Specifications Temperature range outdoor: indoor: Humidity: Language: Operating systems: Internal memory: Supported memory cards: Interface: Dimensions: Weight:

-20 to + 60°C 0 to +40°C 25 to 95% English Windows® Vista™/XP/XP Pro/2000 SP3 128MB SD, MMC, Memory Stick/PRO, Memory Stick (PRO) Duo (card adaptor needed) 2.0 USB device as access card reader and internal memory 220 x 165 x 32mm 2670g

Type Image

1

9.726 409

5 Weather station “diva plus“ - transmission of outdoor temperature and humidity via up to 3 transmitters (max. 100m) - indication of indoor temperature and humidity, - Max./min. function - weather forecast, tendency of atmospheric pressure, bar graph indication of atmospheric pressure of the last 24 hours - radio controlled clock with date, time zone ±12 hrs - interchangeable °C/°F display - wall or table mounting Supplied with: Outdoor temperature and humidity Specifications Temperature range outdoors: indoors: Humidity: Dimensions basis station: Dimensions transmitter: Weight:

TFA Dostmann

transmitter, batteries 5 x 1.5V AA

-40 to +60°C (-14 to 140°F) -10 to +60°C (-4 to 140°F) 1 to 99 % 180 x 100 x 35mm 160 x 43 x 28mm 520g

Type diva plus

350

Cat. No.

4

3

5

PK

E & OE.

PK

Cat. No.

1

9.726 410


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Climate measurement/Special climate meters 1 Moisture meter HumidCheck Mini

1

Easy to use: remove protection cap, press measuring button and insert measuring electrodes in object. - scale for construction materials and wood - automatic instrument test - with clip Applications: Used to measure the moisture level in sawn timber and construction materials. Suitable for field work.

Specifications Measuring principle: Measuring range wood: Accuracy wood: Measuring construction materials: Accuracy construction materials: Temperature range: Batteries: Housing: Dimensions: Weight:

electrical resistance 6 to 42% <30% ±2%; >30% ±4% 0.2 to 2.0% <1.4% ±0.1%; >1.4% ±0.2% 0 to 40°C (32 to 104°F) 4 x coin cell (LR44) impact-resistant plastic 80 x 40 x 20mm 80g (incl. packaging)

Type HumidCheck Mini

PK

Cat. No.

1

9.726 406

2 Meteorograph

2

Triple chart, recording measuring device for the most important meteorological data. With spring-driven movement. Measuring range:

Recording width: Dimensions: Recording time: Humidity measuring element:

Thies

10 to 100 % R.H. -35 to +45°C 945 to 1052 hPa 3 x 82 mm 280 x 140 x 350 mm 1/7 days selectable "H".

Type Meteorograph

PK

Cat. No.

1

9.726 577

3 Rain and snow gauge

3

Hellmann type. Short form. Precipitation can be collected directly into the measuring cylinder. Measuring cylinder: 250 cm³ = 25 mm precipitation Divisions: 1 mm precipitation Collecting area: 100 cm² Dimensions (Dia. x H): 120 x 255 mm

Thies

Type Complete with measuring cylinder Spare 250 ml measuring cylinder

E & OE.

PK

Cat. No.

1 1

9.194 050 9.194 051

351


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Density determination/Density meter, Pycnometer 1

1 Pycnometers, Blaubrand® Borosilicate glass 3.3. DIN ISO 3507, guy-lussac type . Including individual certificate. BRAND Adjusted. With NS10/19 capillary stopper. Stopper top ground and polished. Inscription in highly contrasting blue enamel. Actual volume given to 0.001cm³ accuracy. Calibrated to contain. Every pycnometer is calibrated with its own stopper; hence, stoppers are not interchangeable. Each bottle and its stopper is marked with an unique matching identification number. Nom. capacity cm³ 5 10 25 50 100

2

PK

1 1 1 1 1

Cat. No.

9.277 9.277 9.277 9.277 9.277

305 310 325 350 400

2 Pycnometers, Blaubrand®, with thermometer and side capillary Borosilicate glass 3.3. DIN ISO 3507, guy-lussac type . Including individual certificate. BRAND Adjusted. With thermometer and side capillary. Calibrated to contain. Actual volume given to 0.001cm³ accuracy. Inscription in highly contrasting blue enamel. Thermometer with translucent glass scale, with conical ground joint 10/19. Measuring range 10 to 35°C (0.2°C increments), mercury filled. Side capillary with conical ground joint cap 7/16. Every pycnometer is calibrated with its own stopper; hence, stoppers are not interchangeable. Each bottle and its stopper is marked with an unique matching identification number.

Nom. capacity cm³ 10 25 50 100

3

PK

1 1 1 1

9.277 9.277 9.277 9.277

410 425 450 500

3 Pycnometers, not calibrated Borosilicate glass 3.3. DIN 12797.

Isolab

Capacity ml 5 10 25 50 100

4

Cat. No.

PK 1 1 1 1 1

Cat. No. 9.277 9.277 9.277 9.277 9.277

510 511 512 513 514

4 Hydrometers, relative density (S.G.) Shot poised. Without thermometer. Measuring range g / ml 0.600 to 0.800 0.800 to 1.000 1.000 to 1.200 1.200 to 1.400 1.400 to 1.600 1.600 to 1.800 0.700 to 1.000 1.000 to 1.500 1.500 to 2.000

Subdivisions g / ml 0.002 0.002 0.002 0.002 0.002 0.002 0.005 0.005 0.005

Length

PK

mm 300 300 300 300 300 300 300 300 300

1 1 1 1 1 1 1 1 1

Further models availlable on request.

352

E & OE.

Cat. No.

9.004 9.004 9.004 9.004 9.004 9.004 9.004 9.004 9.004

006 008 010 012 014 016 057 060 065


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Density determination/Density meter, Pycnometer 1 Hydrometers, density, M 100 series

1

DIN 12791 (and BS718). Adjustable. M 100 series. Shot poised. Without thermometer. Reference temperature: +20°C.

Measuring range g / ml 0.800 to 0.900 0.900 to 1.000 1.000 to 1.100 1.100 to 1.200 1.200 to 1.300 1.300 to 1.400 1.400 to 1.500 1.500 to 1.600

Subdivisions g / ml 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002

Length

PK

mm 250 250 250 250 250 250 250 250

1 1 1 1 1 1 1 1

Cat. No.

9.004 9.004 9.004 9.004 9.004 9.004 9.004 9.004

108 109 110 111 112 113 114 115

Further models availlable on request.

2 Hydrometers, density

2

Shot poised. Without thermometer. Reference temperature: +20°C. Measuring range g / ml 0.760 to 0.820 0.820 to 0.880 0.880 to 0.940 0.940 to 1.000 1.000 to 1.060 1.060 to 1.120 1.120 to 1.180 1.180 to 1.240 1.240 to 1.300 1.300 to 1.360 1.360 to 1.420

Subdivisions g / ml 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001

Length

PK

mm 160 160 160 160 160 160 160 160 160 160 160

1 1 1 1 1 1 1 1 1 1 1

Cat. No.

9.004 9.004 9.004 9.004 9.004 9.004 9.004 9.004 9.004 9.004 9.004

153 154 155 156 157 158 159 160 161 162 163

Further models availlable on request.

3 Hydrometers, density

3

General purpose. For measuring relative density (specific gravity). Calibrated at 60/60°F. Measuring range g / ml 0.600 to 0.800 0.800 to 1.000 1.000 to 1.200 1.200 to 1.400 1.400 to 1.600 1.600 to 1.800 1.800 to 2.000 0.700 to 1.000 1.000 to 1.300 1.000 to 1.500 1.300 to 1.600 1.500 to 2.000 0.700 to 2.000

Grad.

Length

PK

ml 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.005 0.005 0.005 0.005 0.005 0.010

mm 300 300 300 300 300 300 300 300 300 300 300 300 300

1 1 1 1 1 1 1 1 1 1 1 1 1

Cat. No.

9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950

001 002 003 004 005 006 007 008 009 010 011 012 013

4 Hydrometers, Baumé

4

Baumé type. Shot poised. Without thermometer. Reference temperature: +15°C.

Measuring range Bé 0 to 5 0 to 10 0 to 15 0 to 20 0 to 30 0 to 40 0 to 50 0 to 70

Subdivisions Bé 0.1 1.0 1.0 1.0 1.0 1.0 1.0 1.0

Length

PK

mm 260 220 230 230 250 250 280 300

1 1 1 1 1 1 1 1

Cat. No.

9.004 9.004 9.004 9.004 9.004 9.004 9.004 9.004

305 310 315 320 330 340 350 370

Further models availlable on request.

E & OE.

353


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Density determination/Density meter, Pycnometer 1

1 Hydrometers, mineral oil With -10 to +60°C thermometer. Adjustable. Reference temperature: +15°C. Measuring range g / ml 0.610 to 0.700 0.680 to 0.770 0.750 to 0.840 0.820 to 0.910 0.890 to 0.990

2

Subdivisions g / ml 0.001 0.001 0.001 0.001 0.001

Length

PK

mm 390 390 390 390 390

1 1 1 1 1

Cat. No.

9.004 9.004 9.004 9.004 9.004

561 568 575 582 589

2 Hydrometers, Dr. Ammer Dr. Ammer type. For testing boiler feedwater. With integral thermometer and temperature correction. Reference temperature +20°C. Measuring range Bé -1 / 0 / +2

3

Length

PK

Cat. No.

mm 290 290

1 1

9.004 601 9.004 602

Length

PK

Cat. No.

mm 300

1

9.004 640

Length

PK

Cat. No.

mm 240

1

9.004 650

3 Hydrometers, lime water For lime water Ca(OH)2. Without thermometer. Reference temperature: +20°C. Measuring range 0 to 340 g / l

4

4 Salinometers Bischoff type. For common salt. Without thermometer. Measuring range g / ml 0 to 27

354

E & OE.


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Density determination/Density meter, Pycnometer 1 Hydrometers for special applications Without thermometer. Total length:

1

250 to 280 mm

For

Measuring range

PK

Ammonia Sodium hydroxide Sodium hydroxide Nitric acid Hydrochloric acid Sulphuric acid Hydrogen peroxide

0 to 35 x 0.5 % 0 to 27 x 1 % 0 to 10 x 0.1 % 0 to 47 x 1 % 0 to 39 x 1 % 45 to 95 x 1 % 0 to 30 x 1 %

1 1 1 1 1 1 1

Cat. No.

9.004 9.004 9.004 9.004 9.004 9.004 9.004

651 652 653 654 655 656 657

2 Hydrometers, density, BS718

2

Density: g/ml at 20째C. Measuring ranges 0.6 to 1.0 are adjusted for liquids with low surface tension. Measuring ranges 1.0 to 2.0 are adjusted for liquids with medium surface tension. Measuring range g / ml 0.600 to 0.650 0.650 to 0.700 0.700 to 0.750 0.750 to 0.800 0.800 to 0.850 0.850 to 0.900 0.900 to 0.950 0.950 to 1.000 1.000 to 1.050 1.050 to 1.100 1.100 to 1.150 1.150 to 1.200 0.800 to 0.900 0.900 to 1.000 1.000 to 1.100 1.100 to 1.200 1.200 to 1.300 1.300 to 1.400 1.400 to 1.500 1.500 to 1.600

Grad.

Length

PK

ml 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002

mm 190 190 190 190 190 190 190 190 190 190 190 190 250 250 250 250 250 250 250 250

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Cat. No.

9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950 9.950

014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033

3 Alcoholometer

3

Richter-Tralles type. 0 to 100 % at reference temperature: +20째C. Without thermometer. Type Alcoholometer

E & OE.

PK

Cat. No.

1

9.004 400

355


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Density determination/Density meter, Pycnometer 1

1 Hydrometer jars PP. With overflow chamber so that hydrometer can be read when cylinder is completely full. Impact resistant and flexible. With spout.

Capacity ml 500

2

Int. dia. mm 50

BRAND

Height

PK

Cat. No.

mm 350

1

9.004 900

PK

Cat. No.

2 Hydrometer jars Glass, with spout and base. Height mm 150 200 200 250 300 350

3

Dia. mm 38 38 50 50 50 63

1 1 1 1 1 1

9.950 9.950 9.950 9.950 9.950 9.950

034 035 036 037 038 039

3 Battery hydrometer Battery acid tester 1.10 to 1.30. Boxed complete with glass tube, rubber bulb and hydrometer. Type Battery hydrometer

4

PK

Cat. No.

1

9.004 710

4 Dipping flow cups Frikmar Aluminium. DIN 53211 viscometer. For all types of liquid chemicals, varnishes, fluid enamels, gravure printing inks and leather dyes, oils, fats, foodstuffs etc. With 4 mm flow nozzle. Accessory 2, 3, 5, 6, 7 and 8 mm nozzles are available on request.

Type Dipping flow cups Frikmar

356

E & OE.

PK

Cat. No.

1

9.149 898


GENERAL CATALOGUE 2010/11

3. Analytical measurement and testing Density determination/Density meter, Pycnometer

Flow cups DIN 53211. With fixed nozzle, 4mm. (Also available with 2, 3, 5, 6, 7 and 8 mm nozzles - details on request) Type Flow cups

1 Flow cups, without nozzles

PK

Cat. No.

1

9.149 862

PK

Cat. No.

1

For 2, 3, 4, 5, 6, 7 and 8 mm outlet detachable nozzles. Type Flow cups

PK

Cat. No.

1

9.149 860

Flow cup nozzles Flow cup nozzles to DIN 53211. For flow cup 9.149 860. Int. bore dia. mm 2 3 4 5 6 7 8

1 1 1 1 1 1 1

2 Flow cup stand, adjustable

9.149 9.149 9.149 9.149 9.149 9.149 9.149

872 873 874 875 876 877 878

2

With adjustable cup holder. For 9.149 862 and 9.149 860. Type Flow cup stand, adjustable

PK

Cat. No.

1

9.149 887

3 Flow cup stand, ring stand

3

Stainless steel. Type Flow cup stand, ring stand

E & OE.

PK

Cat. No.

1

9.149 881

357


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Density determination/Viscosimeter 1 Viscometer SV-10/SV-100 Sine-wave Vibro Viscometer SV-10/SV-100 measures viscosity by detecting the driving electric current necessary to resonate the two sensor plates at constant frequency of 30Hz and amplitude of less than 1mm. - wide range of measurements - temperature measurements: 0 to 160°C - high accuracy: ¹1% of measured value - small sample size of 35ml and optional 10ml sample vial or 13ml quartz glass vial - easy cleaning of stainless steel sensor plates and temperature sensor (all gold plated) - WinCT-Viscosity is software to import the measured data of viscosity and temperature to a PC and graphically display the changes in real-time for your analysis - easy calibration with distilled water (SV-10) - sample heating or cooling with "Water Jacket" - approved measuring method acc. to JCSS (Japan Calibration Service Systems)

2

Type

Measuring range

Unit

SV-10 SV-100

0.3 to 10000 mPAs 1 to 100 Pas

mPAs, Pas, cP, P Pas, P

PK

Cat. No.

1 1

9.901 560 9.901 561

2 Viscometers, glass, kinematic, Ubbelohde Ubbelohde. To ISO/DIS 3105. DIN 51562. BS 188. NF T 60 to 100. Without documentation of the constants. For manual and automatic relative measurements. Type

Capillary

53001 53003 53010 53013 53020 53023 53030 53033 53040

0a 0c I Ic II IIc III IIIc IV

Constant K 0.005 0.003 0.01 0,03 0.1 0.3 1 3 10

SI Analytics GmbH

PK 1 1 1 1 1 1 1 1 1

1

358

A&D Inst.

E & OE.

Cat. No. 9.268 9.268 9.268 9.268 9.268 9.268 9.268 9.268 9.268

301 303 310 313 320 323 330 333 340


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Density determination/Viscosimeter Viscometers, glass, kinematic Ubbelohde. To ISO/DIS 3105. DIN 51562. BS 188. NF T 60 to 100. For manual or automatic measurements. Constants documented in manufacturer's certificate. Type

Capillary

501 501 501 501 501 501 501 501 501 501 501 501 501 532 532 532 532 532 532

0 0c 0a I Ic Ia II IIc IIa III IIIc IIIa IV I Ic II Iic III Iiic

00 03 01 10 13 11 20 23 21 30 33 31 40 10 13 20 23 30 33

Capillary Constant i.d. mm 0.36 0.47 0.53 0.63 0.84 0.95 1.13 1.50 1.69 2.01 2.65 3.00 3.60 0.63 0.84 1.13 1.50 2.65 3.60

K 0.001 0.003 0.005 0.01 0.03 0.05 0.1 0.3 0.5 1 3 5 10 0.01 0.03 0.1 0.3 3 10

SI Analytics GmbH

Measuring range

PK

mm2 / sec 0.2 to 1 0 to 3 0.8 to 5 1.2 to 10 3 to 30 5 to 50 10 to 100 30 to 300 50 to 500 100 to 1000 300 to 3000 500 to 5000 1000 to 10000 1.2 to 10 3 to 30 10 to 100 30 to 300 300 to 3000 1000 to 10000

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 Viscometer holders

Cat. No.

9.268 9.268 9.268 9.268 9.268 9.268 9.268 9.268 9.268 9.268 9.268 9.268 9.268 9.268 9.268 9.268 9.268 9.268 9.268

100 103 101 110 113 111 120 123 121 130 133 131 140 210 213 220 223 230 233

1

Type 05392. SI Analytics GmbH VA steel. Suitable for all Ubbelohde viscometers without TC sensors. For manual and automatic measurements. Holds the viscometer perpendicularly. Accuracy <1째. Protects the viscometer from damage.

Type 05392

PK

Cat. No.

1

9.268 790

2 2 Viscometer heating jacket With support plate for Ubbelohde and capillary viscometers. Can be thermoregulated in mantles in the temperature range 0 to 180째C. Type Viscometer heating jacket

SI Analytics GmbH

PK

Cat. No.

1

9.269 420

3 Viscometers

3

U-tube. Calibrated to ASTM D455-IP71, BS188 and ISO3105 against a primary standard traceable to all international standards. All viscometers can be used with transparent liquids. To ASTM D455-IP71, BS188, ASTM D446; 51562, BS2000 Section 71, ISO3104, ISO3105. Size

Nominal constant

Viscosity range

PK

O A B C D E

0.001 0.003 0.01 0.03 0.1 0.3

0.3 to 1 0.9 to 3 2.0 to 10 6 to 30 20 to 100 60 to 300

1 1 1 1 1 1

E & OE.

Cat. No.

9.950 9.950 9.950 9.950 9.950 9.950

040 041 042 043 044 045

359


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Density determination/Viscosimeter 1 Automatic viscometer ViscoClock Introductory model for automatic viscosity analysis. For determining absolute and relative viscosity.

SI Analytics GmbH

The most precise method for determining the viscosity of liquids is to measure it in capillary viscometers. The ViscoClock works in accordance with this method. Optical fibres precisely determine the liquid meniscus on two measuring planes, the running time is determined and displayed with a resolution of 0.01 secs. Since the measuring process runs automatically, subjective sources of error are reliably excluded. The 0.01% accuracy of the measured time for calculating the absolute and relative viscosity is given as a measuring uncertainty with a confidence level of 95 %. The ViscoClock was designed to use of Ubbelohde, micro Ubbelohde or micro Ostwald viscometers and can be operated in all thermostatic baths with transparent tanks. Measuring range: Timing accuracy: Measuring range viscosity:

RS 232C interface: Operating temperature: Dimensions (WxDxH): Weight: Viscometers accepted:

Up to 999.99 secs./resolution 0.01 sec. ±0.01 sec. ±1 digit, but not more accurate than 0.1%, given as measuring uncertainty with a confidence level of 95% 0.35 to 10000 mm²/sec. (cSt) The absolute, kinematic viscosity is also dependent on the uncertainty of the numerical value of the viscometer constants and on the measuring environment, in particular the measuring temperature For connecting a printer with a serial interface or a computer (PC) for documenting the data Stand: -40 to +150°C Electronic measuring unit: +10 to +40°C approx. 95 x 50 x 490 mm approx. 450g (without viscometer) Power pack approx. 220g Ubbelohde (DIN, ISO, ASTM, micro), micro Ostwald.

Type ViscoClock

1

360

E & OE.

PK

Cat. No.

1

9.269 480


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Density determination/Viscosimeter 1 Viscometers, Haake Viscotester® 6 plus and 7 plus

1

The Haake Vicostester 6 plus and 7 plus are classical rotation viscometers, in which the Thermo Electron resistance of the media under test is measured against the speed. The result of the shear modulus is a dimension for the viscosity of the liquid sample. Due to the the geometry of the spindle the actual shear rate can only be measured in Newtonian units. Type Haake Vicotester 7 plus With RS232 interface for data transfer and for control by PC using the measuring and control software Haake RheoWin (optional). Pt100 temperature probe for measuring sample temperature. A lot of international Norms use the Brookfield method for description of viscosity. The viscotester fulfils the requirements of the following norms: BS:6075, 5350 ISO:2555, 1652 ASTM:115, 789, 1076, 1084, 1286, 1417, 1439, 1638, 1824, 2196, 2336, 2364, 2393, 2556, 2669, 2849, 2983, 2994, 3232, 3236, 3716. Range of viscosity Version L: 3 to 6.000.000 mPas in 84 ranges (21 speeds with 4 spindles for low and medium viscosity substances. Range of viscosity Version R: 20 to 40.000.000 mPas in 126 ranges (21 speeds with 6 spindles for medium and high viscosity substances. Items supplied: The viscotester is delivered in a rigid carrying case and multilingual documentation. Each basic model has a laboratory stand and a complete set of spindles with rack.

display: standardized speed in rpm: inaccuracy: torque: uncertainty of meaurement: reproducibility:

dynamic viscosity in mPas, measuring moment % of the ultimate value, Speed in rpm, Spindle Number, Temperature in °C (Model 7plus only) <±0.5 % of absolute point 0.1; 0.2; 0.3; 0.5; 0.6; 1; 1.5; 2; 2.5; 3; 4; 5; 10; 12; 20; 30; 50; 60; 100; 200 Versions L and R have a differentiation factor of 6. ±1% of the ultimate value ±0.2%

Type

Description

VT6L plus VT6R plus VT7L plus RheoWin/VT7L

Haake Viscotester VT6L 100-240V 50/60Hz Haake Viscotester VT6R plus 100-240V 50/60Hz Haake Viscotester VT7L plus 100-240V 50/60Hz RheoWin Software for control of VT7L plus, data acquisition and evaluation Haake Viscotester VT7R 100-240V 50/60Hz RheoWin Software for control of VT7R plus, data acquisition and evaluation

VT7R plus RheoWin/VT7R

PK

Cat. No.

1 1 1 1

9.885 9.885 9.885 9.885

074 075 076 077

1 1

9.885 078 9.885 079

We can supply this

manufactorer’s whole product range ! E & OE.

361


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Density determination/Viscosimeter 1 Laboratory Viscometer ProRheo R180 ProRheo R180 is both a portable and "stand alone" rotational viscometer. - rugged instrument housing - easy to use and wide measurement range - relevant parameters can be stored - measuring systems according to DIN 53018ff - measurement accuracy: < 1 % - measurement range: 5 mPas to 540.000 mPas - Torque: 0.25 to 10 mNm Âą0.01 mNm - rotational speed: 5 to 1000 rpm - Measurement programmes: 8 measurement points at different shear rates: 2 predefined test set-ups, 8 programmable test set-ups. R180 viscometer includes: - Power supply - stand - measuring tubes 1, 2 and 3 - measuring bobs 1, 2 and 3 - tube caps 1, 2 and 3 - Instrument case - Operating instructions Application table for measuring tubes and bobs

Type

Measuring system

R180 R180 R180

11 22 33

Tube dia. mm 32.5 26.1 15.2

External body dia. mm 30 24 14

Viscosity min. mPa. 5 10 20

Viscosity max. mPa. 10000 20000 100000

Capacity ml approx. 24 approx. 16 approx. 9

All applications are done with the same instrument.

1

362

E & OE.

PK

Cat. No.

1 1 1

9.106 650 9.106 650 9.106 650


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Analytical instruments and systems/Melting point determination 1 Laser Particle Sizer Analysette 22 MicroTec plus

1

For rapid, automatic particle size analysis of solids, dry or in suspension and emulsions Fritsch through laser diffraction in a convergent laser beam. The Analysette 22 MicroTec plus offers an extra wide measuring range of 0.08 to 2000µm in a single, exceptionally small, instrument. The MaS control software included enables perfect dispersion and navigates you through the entire measuring process, analysis and cleaning - and this in all fields of applications for an extraordinarily low price. Typical applications: The Analysette 22 is used worldwide in production testing and quality control, as well as in research and development. With short analysis times, consistently reproducible and reliably comparable results, it offers decisive advantages in the precise determination of particle sizes by laser diffraction. Operation/Design: The Analysette 22 uses the physical principle of electromagnetic wave scattering for the analysis of the particle size distribution. The Analysette 22 MicroTec plus is developed as a highly practical, modular system with perfectly conceived units for dry and wet dispersion. All dispersion modules can be connected to the measuring unit individually, or in combination and can easily be adjusted or upgraded for new measurement tasks. Overview of performance features: - compact size - compact price - extra-wide measuring range 0.08 to 2000 µm - exceptionally high reproducibility - revolutionary, dual-laser-technology - practical modular system - quick change between wet and dry measurement - variable suspension volume with the wet dispersion unit - simple cleaning - small footprint - 24 month warranty

Specifications: Method of analysis: Measuring: Measuring range: Analysis: Measuring time: Weight: Dimensions (WxDxH):

Laser diffraction (Scattering) any solids dry or in suspension and emulsions 0.08 to 2000µm according to Fraunhofer or Mie theory with the Fritsch MaS control software 5 to 10sec. 38kg (Measuring unit) 30kg (Wet dispersion unit) 530 x 620 x 350mm (Measuring unit) 320 x 620 x 440mm (Wet dispersion unit)

Description Measuring unit Wet dispersion unit Dry dispersion unit

PK

Cat. No.

1 1 1

9.739 026 9.739 027 9.739 028

We can supply this

manufactorer’s whole product range ! E & OE.

363


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Analytical instruments and systems/Melting point determination 1 Melting point apparatus, Electrothermal IA 9100/9200 With microprocessor heating oven control. Up to 3 melting points can be quickly and accurately determined simultaneously. The ramp starting temperature of the approximate melting range can be input via the keyboard. The units quickly heat up to this temperature and give an optical and acoustic signal once it has been reached. By the operator then pressing another key, the devices begin to heat up at a constant rate (IA 9100 fixed at 1°C/min., IA 9200 adjustable between 0.2 to 10°C/min. in increments of 0.1°C). Up to 4 melting points can be recorded and transferred to the memory as discreet temperatures for later recall on the display. The different phases of a melt or the critical melting temperatures of various samples can be investigated under the same conditions in this way. Model IA 9200 provides the opportunity for computer-supported data analysis. The initial temperature and heating rate can be set via the keyboard in order that various test protocols are available. An accessory printer enables documentation of the results, date, time (real time) and sample number. Model IA 9200 can allocate continuous sample numbers or recall data via the keyboard. Information can be transferred directly to a LIMS computer via the RS 232 C interface. The 8X magnifier has a Ø of 40mm and an adjustable focal point. Units comply with VDE requirements.

Dimensions (WxDxH): Weight: Input: Output: Power: Oven output: Oven chamber illumination: Oven temperature range: Digital thermometer Sensor: Measuring range: Resolution: Accuracy: Display:

200 x 350 x 85 mm 2.5 kg 220-240 V 12 V 45 W 18 W 12 V 2.2 W 45 to 400°C linearised industrial platinum resistance thermometer, compensated Amb. to 400°C 0.1°C ±0.6°C at 50°C ±1 digit ±1.0°C at 350°C ±1 digit Four-digit, 12 mm high LCD

Type IA 9100 IA 9200

PK

Cat. No.

1 1

9.830 441 9.830 442

PK

Cat. No.

Melting point apparatus, Electrothermal IA 9100/9200, accessories For IA 9100/9200 Type Cold finger Dust cover Calibration set Interface cable for serial printer Capillary tubes, 2.0 mm Ø Printer with connection cable Cal. std. Carbazole (245.61 °C) 0.5 g Capillary tubes, 1.5 mm Ø

1 1 1 1 100 1 1 100

1

364

E & OE.

9.830 9.830 9.830 9.830 9.830 9.830 9.830 9.830

445 446 451 452 447 448 469 463


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Analytical instruments and systems/Melting point determination 1 2 Melting point apparatus, model SMP10

1

- Resolution 1°C - Maximum temperature 300°C - Digital temperature setting and control with LED readout - Pt100 temperature sensor - Two heating ramp rates: - 20°C/minute to plateau temperature - 2°C/minute to melt - Accepts up to 2 sample tubes - Built-in sample illumination - Accuracy : ±1°C at 20°C WxDxH 160 x 220 x 170 mm Weight 1.8kg. For 230 V 50 Hz supplies. Supplied with 100 melting point tubes, open one end. With BioCote, silver-based, antimicrobial protection.

Stuart

2

Type SMP10

PK

Cat. No.

1

9.950 177

3 4 5 Melting Point Apparatus, advanced, SMP30 -

3

Maximum temperature 400°C Patented head up display Integrated cooling 350°C to 50°C in 10 minutes Large easy to read user friendly interface

Stuart

The SMP30 can take three samples simultaneously within the optimised heating block. To allow maximum flexibility a plateau facility is included with variable ramp rate between 0.5 and 10°C in 0.1°C increments. The tubes are illuminated with bright white LEDs to give the clearest view of the samples during the melt. The block has been designed for easy access for cleaning. To allow the most comfortable viewing angle the SMP30 features a two stage head adjustment. The SMP30 features the patent pending head up display, this unique feature displays a floating image of the block temperature, visible through the eyepiece, in front of the tubes.

4

An accessory printer is available separately to produce a written record of the melt. Specifications No of samples: Temperature range: Temperature resolution: Display: Ramp rates: Memory: Date/time display: Cool down time: Heat up time: Supply requirements: Language variants: Temperature units:

3 Ambient to 400°C 0.1°C 40 x 4 segment LCD 0.5 to 10°C in 0.1°C increments 8 results per tube Yes 350 to 50°C (~12 mins) 50 to 350°C (~ 6 mins) 120V/230V 50Hz English, German, French, Italian °C

Type Melting point apparatus, complete with pack of 100 melting point tubes, closed at one end. Melting point tubes, closed at one end.

E & OE.

5

PK

Cat. No.

1 100

9.950 188 6.803 067

365


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Analytical instruments and systems/Melting point determination 2

1 2 Automatic Melting Point Apparatus, SMP40 -

maximum temperature 400°C utilises latest technology in digital imaging 5.7" colour VGA touch screen display unique split design concept integrated cooling: 350°C to 50°C in 10 minutes

Stuart

The SMP40 automatic melting point uses the latest technology in digital image processing to accurately identify the melt of up to three samples simultaneously. The unit comes with a 5.7" colour VGA display, on which the melt can be watched real time, or the melt video will automatically be saved as an AVI file that can be reviewed later, either on the unit or via PC. The result can also be overridden if for any reason the operator does not agree with the result calculated by the image processing algorithm. The SMP40 has an innovative split design concept, the unit can be used as normal or the control side and the melt side can be separated, allowing maximum footprint flexibility. Once the unit has been split the control panel side can be used in two orientations, either landscape or portrait to allow the perfect viewing angle whether you are sat or stood at the bench, the screen automatically changes orientation with the unit. The unit can store up to 200 result files with videos, if required data can be easily transferred from the unit to a flash memory drive or PC via one of the USB connectors. All units are supplied with a calibration certificate showing individual serial numbers for traceability. The SMP40 conforms to Pharmacopeia and GLP.

Specifications No of samples: Temperature range: Temperature resolution: Display: Ramp rates: Memory: Date/time display: Cool down time: Heat up time: Flash memory/PC interface: Supply requirements: Language: Temperature units:

3 simultaneously Ambient to 400°C 0.1°C 5.7“ Colour VGA touchscreen 1.1 to 10°C in 0.1°C increments 200 results with video Yes 350 to 50°C (approx. 10 mins) 50 to 350°C (approx. 6 mins) USB 120V, 230V 50Hz a.c. English °C, °F, °K

Type Melting point apparatus, incl. 100 melting point tubes, closed at both ends Glass melting point tubes, closed at both ends

PK

Cat. No.

1 100

9.950 398 9.950 400

1

3

3 Melting point apparatus, Thiele tube Thiele pattern tube. With side limb.

Lenz

Type Melting point apparatus

366

E & OE.

PK

Cat. No.

1

9.208 000


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Analytical instruments and systems/Melting point determination-Spectrophotometers 1 Melting point tubes

1

Capillary tubes for melting point analysis, one end closed. Clear glass, different diameters and lengths. Special remarks are available. Other sizes on request.

Type

Length mm 75 80 100 80 100

Sealed one end Sealed one end Sealed one end Open both ends Open both ends

Ext. dia. mm 1.6 1.0 1.0 1.0 1.0

Hirschmann

Int. dia. mm 1.20 0.80 0.80 0.80 0.80

PK

100 100 100 100 100

2 3 Spectrophotometer/Colorimeters Lovibond PFX995, PFX950, PFX880 Series

Cat. No.

9.208 9.208 9.208 9.208 9.208

076 081 101 080 100

2

Automatic colorimeters for oils, fats, chemicals, fuels and other transparent Tintometer samples. A series of high-precision, spectrophotometric colorimeters offering measurement options that vary from focussed instruments for specific colour scales through to a flexible, full-scale package. An integrated sample heater unit is available as a factory fitted option for maintaining samples such as fats and waxes in a liquid state. These colorimeters are easy to use, automatic instruments. There is no need to build up calibration curves as they are already established in the instruments. The menu system guides operators through the selection of operating parameters. Thereafter, measurements are initiated by just a single key press and take less than 25 seconds to complete. Each instrument accommodates cells up to 153 mm (6") path length, ensuring precise colour measurement even with unsaturated samples such as solvents and white oils. Ruggedly built, with fabricated steel housings, they function equally as QC instruments within the laboratory or on 24-hour operation in a production environment.

Type PFX995:

PFX880/L: PFX995/P: PFX880/P:

Scales Lovibond RYBN, AOCS-Tintometer Colour, Gardner Colour, Pt-Co/Hazen/APHA Colour, FAC Colour, Chlorophyll A & B, beta Carotene, Iodine Colour, Hess-Ives Colour Units, Klett Colour, Cross Value, CIE Values, Spectral Data Lovibond RYBN, CIE Values, Spectral Data Saybolt Colour, ASTM Colour, Pt-Co/Hazen/APHA Colour, Gardner Colour, Lovibond RYBN, IP Units, CIE Values, Spectral Data Saybolt & ASTM Colour, CIE Values, Spectral Data

Type

PK

PFX995 PFX995 + heater PFX880/L PFX880/L + heater PFX995/P PFX995/P + heater PFX880/P PFX880/P + heater

1 1 1 1 1 1 1 1

Cat. No. 9.947 9.947 9.947 9.947 9.947 9.947 9.947 9.947

319 320 321 322 323 324 325 326

Each instrument is supplied complete with optical glass cells of the relevant path lengths for each of the colour scales included, a calibrated glass conformance filter, a spare lamp and instructions.

3

E & OE.

367


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Analytical instruments and systems/Spectrophotometers 1 Automatic Transmittance Colorimeters, Lovibond PFX195 Series

1

Tintometer d- consistent and reliable colour data - comprehensive and flexible choice of standard colour scales - remote upgrade facility for adding scales once in service - allows calculation and description of off-hue status - gives closest match to stored references - generates a customised colour scale from reference samples - robust design that is easy to operate and maintain - includes a glass colour standard for conformance checks - supplied with colour control software for data analysis - output conforming to GLP including date, time, sample and user ID - accommodates a range of sample cells and tubes d A series of spectrophotometric colorimeters for colour grading of light transmitting samples. Each version of the PFX195 includes a selection of standard colour scales that are used in a specific industry sector; additional scales can be added as optional upgrades. Results can also be displayed in terms of spectral data and CIE values. dDetails of the most popular PFX195 versions are shown below. Versions that include FAC Colour, Klett Colour (blue filter KS-42), Hess-Ives Colour Units, Yellowness Index, US Naval Stores Rosin, Chinese Pharmacopoeia, ICUMSA Colour and Pfund/Honey are also available. d Type

For

Colour scale

PK

Cat. No.

PFX195/1

Liquid chemicals & industrial oils

Pt-Co/Hazen/APHA, Gardner, Iodine, CIE Values, Spectral data Saybolt, ASTM Colour, Pt-Co/Hazen/APHA, CIE Values, Spectral data EBC Colour, ASBC Colour, Series 52 (Brown), CIE Values, Spectral data

1

9.947 327

PFX195/2

Petroleum oils & fuels

1

9.947 328

PFX195/4

Beers, malts & caramels

1

9.947 329

PFX195/5

Pharmaceutical solutions

European/US Pharmacopoeia, Pt-Co/Hazen/ APHA, CIE Values, Spectral data

1

9.947 330

Each PFX195 is supplied complete with optical glass cells for the colour scales included, a certified glass filter of specified colour value for regular conformance testing, a spare lamp and instructions.

2

2 Visual Colorimeter, Lovibond Tintometer Model F Individually housed glass colour standards Prismatic optical system for accurate and repeatable colour matching Standardised and diffused tungsten-halogen light source Replacement inserts simplify cleaning and maintain interior whiteness

Tintometer

The Model F is a versatile visual colorimeter for measuring the colour of liquids, solids, powders and pastes in terms of Lovibond units. The user simultaneously compares the colour of light that is either transmitted through or reflected from the sample with that transmitted through a series of glass colour filters in 3 primary colours - red, blue and yellow. The slides are adjusted until a visual colour match is found for the light from the sample and the colour is then expressed in Lovibond RYBN units. The Model F is supplied with a complete set of Lovibond coloured glass filters (Red 0.1 to 70; Yellow 0.1 to 70; Blue 0.1 to 40; Neutral 0.1 to 3.0), a sample chamber insert for easy cleaning, fused glass cells (one each of 1" and 5Âź"), accessories and instructions. An optional solid sample accessory pack is available for measuring light-reflecting products. Includes a 12 Volt a.c. power pack switchable to suit 110/220/Volt supply.

Description Tintometer Model F

PK

Cat. No.

1

9.947 340

Each instrument is supplied with optical cuvettes of the appropriate path length for the individual colour scales, calibration filter, spare lamp and operating instructions.

368

E & OE.


GENERAL CATALOGUE 2010/11

3. Analytical measurement and testing Analytical instruments and systems/Spectrophotometers

Accessories for visual Colorimeter, Lovibond Tintometer Model F Tintometer Description

PK

½“ optical glass cell 1“ optical glass cell 5¼“ optical glass cell 1“ borosilicate glass cell 5¼“ borosilicate glass cell Replacement sample chamber insert for Model F Accessory pack for solid sample measurement

1 1 1 1 1 3 1

Cat. No. 9.947 9.947 9.947 9.947 9.947 9.947 9.947

341 342 343 344 345 346 347

1 Reflectance Tintometers, RT100, Lovibond

1 Tintometer

d- low cost spectral system - 0º/45º measuring geometry - compact, lightweight unit - rapid reflectance data at the click of a button - storage of reference and measured values - certified calibration standard included dCompact, lightweight colorimeter, giving spectral reflectance data for quality control of surface colour. It combines advanced microspectrometer technology with the computing power of a PC. The measuring head links to a standard PC computer with software installed for instrument operation and for presentation, analysis and logging of reflectance data. Results can be expressed in a choice of colour values and colour difference measurements: X Y Z tristimulus values, CIE L*a*b*, CIE x y Y, CIE L'u'v', CIE L*C*h*, Whiteness Index, Yellowness Index, ΔE, ΔL*, Δa*, Δb*, ΔC*, Δh*colour differences, reflectance, metameric index. Type RT100 Reflectance Tintometer

PK

Cat. No.

1

9.947 337

2 Comparator Lovibond 3000 Visual comparators for colour grading. A series of 3-field instrument designed for visual colour grading by direct comparison between the sample and coloured glass standards. The sample and two adjacent glasses on the colour scale are viewed simultaneously, making it easier to achieve the optimum colour match. The tungsten halogen light source is colour corrected to CIE Standard Illuminant C (B for the EBC Comparator 3000) and guarantees constant lighting conditions for colour grading. Versions of the Comparator 3000 are available for the following scales, each supplied with the appropriate range of colour standards and sample containers:

Tintometer

Type Typical Applications AF 228 Gardner Comparator 3000: Chemicals and oils including resins, varnishes, drying oils and fatty acids (ASTM D1544; ISO 4630, AOCS Methods Ja 9-87, Td 1a-64, Td 3a-64). AF 650 Petroleum Oils Petroleum oils and fuels (ASTM D1500; IP 196; DIN 51 578; ISO 2049; BS 5859) Comparator: AF 607 EBC Comparator 3000: Beers, malt worts, caramels and similarly coloured liquids (Analytica)

Type AF 607 EBC-Comparator 3000 AF 650 Mineral oil-Comparator AF 228 Gardner Comparator 3000

PK

Cat. No.

1 1 1

9.600 705 9.600 706 9.600 728

2

E & OE.

369


3. Analytical measurement and testing

GENERAL CATALOGUE 2010/11

Analytical instruments and systems/Spectrophotometers 1 Nessleriser Systems, Pt-Co/Hazen/APHA Scale, Lovibond For colour grading of clear, light yellow liquids such as clear oils, chemicals, Tintometer petrochemicals and water. Each system covers a set measuring range and includes: - A visual comparator instrument with a long path length, ensuring good sensitivity and accuracy when grading pale coloured samples. - A selection of Pt-Co/APHA colour standards - stable-coloured glass filters in test discs, which have been precalibrated to give direct Pt-Co Colour readings over set measuring ranges. - A standardised bench-top light source to ensure constant and uniform lighting conditions for colour matching and therefore consistent and accurate readings. - Nessler cylinders of the appropriate path length.

Model AF 329:

Apparatus included Nessleriser 2150 with Daylight 2000 Lighting Unit and 113mm (50ml) Nessler cylinders, Nessleriser 2250 upgrade with 250mm Nessler cylinders, Pt-Co discs CAA (0 to 30mg Pt/l) CAB (30 to 70mg Pt/l), NSB (70 to 250mg Pt/l), stand for using Nessleriser with na Nessleriser 2150 with Daylight 2000 Lighting Unit and 113 mm (50 ml) Nessler cylinders, Pt-Co discs NSH (10 to 90 mg Pt/l), NSB (70 to 250 mg Pt/l), stand for using Nessleriser with natural light. Nessleriser 2250 with Daylight 2000 Lighting Unit and 250 mm Nessler cylinders, Pt-Co discs CAA (0 to 30 mg Pt/l), CAB (30 to 70 mg Pt/l), stand for using Nessleriser with natural light.

AF 325:

AF 328:

Type

Pt-Co range

AF 329 AF 325 AF 328

0 to 250 mg Pt/l 10 to 250 mg Pt/l 0 to 70 mg Pt/l

1

370

E & OE.

PK

Cat. No.

1 1 1

9.947 334 9.947 335 9.947 336


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.