SMART power design
ENATEL | 2010 PRODUCT CATALOGUE We are specialists in the design and manufacture of a range of standby power solutions for the telecom, networking, wireless and industrial markets. Enatel’s smart power design offers intelligent solutions at an empowering price. In a market where only the fast survive, we respond quickly and cost-effectively so our customers can do the same.
Offering a range of solutions from small standalone systems for applications like access nodes to medium systems for radio base stations for mobile networks and larger systems for central office power applications. Our knowledge and experience of the global marketplace, along with our talented team, enable us to create power supply solutions that meet each customer’s unique specifications no matter what volume they require.
We not only create our own suite of products, we also offer a comprehensive contract manufacturing service. Our highly flexible environment allows us to specialize in small to medium volume as well as highly repetitive production.
AC-DC POWER SYSTEMS........................................................................... 4
FLAT MOUNT RECTIFIERS........................................................................ 34
1U MICRO COMPACT SYSTEM 0.8 - 2.4kW 48V DC........................................ 5
RF SERIES FLAT MOUNT RECTIFIERS............................................................ 35
1U ULTRA COMPACT SYSTEM 1.0 - 4.0kW 48V DC........................................ 6 1U ULTRA COMPACT SYSTEM 1.0 - 4.0kW 48V DC........................................ 7
WALL MOUNT RECTIFIERS....................................................................... 36 RW SERIES WALL MOUNT RECTIFIERS......................................................... 37
2U ULTRA COMPACT SYSTEM 1.0 - 6.0kW 48V DC........................................ 8 2U ULTRA COMPACT SYSTEM 1.0 - 6.0kW 48V DC........................................ 9
DC-AC POWER SYSTEMS......................................................................... 38
2U ULTRA COMPACT SYSTEM 1.0 - 8.0kW 48V DC...................................... 10 3U COMPACT SYSTEM 1.0 - 6.0kW 48V DC................................................... 11 3U COMPACT SYSTEM 1.0 - 6.0kW 48V DC................................................... 12 3U COMPACT SYSTEM 1.0 - 8.0kW 48V DC................................................... 13 5U MAXI COMPACT SYSTEM 1.0 - 14.0kW 48V DC....................................... 14
DC-AC INVERTERS...................................................................................... 39 IM SERIES MODULAR INVERTERS.................................................................. 40 SBM SERIES STATIC BYPASS MODULE........................................................ 41
DC-DC CONVERTERS. ............................................................................... 42
5U MAXI COMPACT SYSTEM 1.0 - 14.0kW 48V DC....................................... 15
CM SERIES 1.7kW MODULAR DC-DC CONVERTERS.................................... 43
5U MAXI COMPACT SYSTEM 1.0 - 14.0kW 48V DC....................................... 16
CM SERIES 500W to 1.0kW MODULAR DC-DC CONVERTERS..................... 44
6U MAXI COMPACT SYSTEM 1.0 - 22.0kW 48V DC....................................... 17 15U MEDIUM SYSTEM 3.0 - 27.0kW 48V DC.................................................. 18 2.0M MEDIUM SYSTEM 3.0 - 54.0kW 48V DC................................................. 19 2.2M INTEGRATED BASE TRANSCEIVER STATION SYSTEM 1.0 - 16.0kW 48V DC......................................................... 20
MONITORING................................................................................................ 45 SM36 SUPERVISORY MODULE....................................................................... 46 SM35 SUPERVISORY MODULE....................................................................... 47 SM32 SUPERVISORY MODULE....................................................................... 48 SM31 SUPERVISORY MODULE....................................................................... 49
1.6M MEDIUM SYSTEM 3.0 - 27.0kW 48V DC................................................. 21
SM11 SUPERVISORY MODULE....................................................................... 50
2.0M LARGE DATA CENTER SOLUTIONS....................................................... 22
FAN CONTROLLER BOARD............................................................................. 50
WALL MOUNT SYSTEM 4.0kW 48V DC / 2.1kW 24V DC................................ 23
BATTERY CONDITION MONITOR.................................................................... 51 AC MAINS MONITOR........................................................................................ 51
MODULAR RECTIFIERS.............................................................................. 24 RM3048 3.0kW 48V DC MODULAR RECTIFIER............................................... 25
FTTX POWER SOLUTIONS........................................................................ 52 nSURE 1U MICRO COMPACT SYSTEM 0.8 - 2.4KW 48V DC......................... 53
RM3048/24 3.0kW 48V DC / 1.7kW 24V DC MODULAR RECTIFIER............... 26
nSURE NS300-12.............................................................................................. 54
RM3060/48 3.0kW 60/48V DC MODULAR RECTIFIER.................................... 27
nSURE NS30-12................................................................................................ 55
RM2324 2.3kW 24V DC MODULAR RECTIFIER............................................... 28 RM2048XP 2.0KW 48V DC MODULAR RECTIFIER.......................................... 29 RM2048/24 2.0kW 48V DC / 1.0kW 24V DC MODULAR RECTIFIER............... 30 RM1860/48 1.8kW 60/48V DC MODULAR RECTIFIER.................................... 31
INDUSTRIAL SOLUTIONS.......................................................................... 56 2U ULTRA COMPACT SYSTEM 3.0 - 6.0kW 110V DC.................................... 57 WALL MOUNT BATTERY CHARGER 3.0kW 110V DC..................................... 58 RM30110 3.0KW 110V DC MODULAR RECTIFIER.......................................... 59
RM1048 1.0kW 48V DC MODULAR RECTIFIER............................................... 32
SM34 SUPERVISORY MODULE....................................................................... 60
RM848 800W 48V DC MODULAR RECTIFIER.................................................. 33
SM33 SUPERVISORY MODULE....................................................................... 61 ENATEL | 2010 PRODUCT CATALOGUE |
AC-DC POWER SYSTEMS - World leading power density.
Our DC power systems are designed to meet the requirements of
- Fully featured telecom
telecommunications applications requiring high reliability and optimum
performance with easy expansion by way of hot pluggable modular rectifiers.
grade rectifiers.
- Network monitoring available. - Modular 19� design for ease
of installation.
- Includes AC surge protection. - More room for revenue
creating equipment.
- Upgrade existing systems
to higher power.
They are the ideal solution for powering telecommunications and data networks requiring 24V, 48V or 60V DC. We offer a range of solutions for applications from small standalone systems for applications like access nodes to medium sized systems for radio base stations for mobile networks to larger systems for central office power applications.
- High reliability means less cost
Systems are configured using Enatel’s state of the art high frequency switch
mode rectifier modules, intelligent network capable controllers, AC & DC
of maintenance.
- Full remote monitoring available
distribution modules, and cabinets, and can be customized and configured to
meet individual customer requirements.
means less site visits and less cost.
- Cost competitive. - Suitable for more harsh
environments.
| ENATEL | 2010 PRODUCT CATALOGUE
For details on a Enatel power system that meets your requirements contact us.
1U MICRO COMPACT SYSTEM 0.8 - 2.4kW 48V DC AC Input:
Single phase.
AC Current:
170V AC, 15.0A max. 230V AC, 11.1A nominal.
(refer to RM8xx, series brochures for full details)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full load)
Termination:
Single phase, 1.5m flying lead.
48 2.4
V
nominal output voltage.
DC Output Nominal Voltage:
-48V
Rated System Output Power:
2400W max. (50A @ -48V; 44.4A @ -54.0V)
Polarity:
Positive earth. (negative earth available to special order).
kW
maximum output power.
DC Distribution:
Load:
2x 10A, 2x 20A load circuit breakers.
Battery:
2x 30A battery circuit breakers.
Breaker Fail Detection:
Supervisory Module
RM848
RM848
RM848
SM36
Electronic fail detection on both load and battery breakers.
DC Terminals (Front Connected):
Load:
6mm² push-in spring cage.
Battery:
55A power-pole plug-in connectors.
Low Voltage Disconnect:
50A battery LVD (magnetically latching) fitted as standard.
Mechanical Dimensions, W,H,D:
482.6mm (standard 19” module), also fits ETSI 515mm mounting cabinet,
44.45mm (1U, 1.75”), 285mm (11.6”)
Weight:
5kg (excluding rectifier modules)
Shipping Dimensions, W,H,D: 540mm, 95mm, 400mm Weight:
6kg (excluding rectifier modules)
Monitoring & Control:
Various monitoring options are available via the Enatel SM35/36 series
of control & supervisory modules. Standard features include full
temperature compensation, automated and manual battery testing/
equalisation, 6x general purpose inputs and 6x voltage-free relay alarm
outputs. For further details, refer to the SM35/36 series of brochures.
Accessories ACA-BC08P2:
2m, 8mm Ø battery cable kit. (other lengths available to special order)
Part Numbers:
Actual part numbers will vary with configuration.
PSX1606211F-000:
Micro compact system, 2x 800W 48V rectifiers, 6x load
2x battery MCB’s, front termination, SM35 supervisory module.
PSX1606221F-000:
Micro compact system, 2x 800W 48V rectifiers, 6x load
2x battery MCB’s, front termination, SM36 supervisory module.
PSX2404211F-000:
Micro compact system, 3x 800W 48V rectifiers, 4x load
2x battery MCB’s, front termination, SM35 supervisory module.
PSX2404221F-000:
Micro compact system, 3 x 800W 48V rectifiers, 4x load
2x battery MCB’s, front termination, SM36 supervisory module. ENATEL | 2010 PRODUCT CATALOGUE |
1U ULTRA COMPACT SYSTEM 1.0 - 4.0kW 48V DC
48 4.0 V
nominal output voltage.
maximum output power.
SM32
Single phase. (refer to RM series brochures for full details)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full load)
Termination:
Single phase, 10mm² L, N, E tunnel terminals.
DC Output
kW
Supervisory Module
AC Input:
Nominal Voltage:
-48V (+24V available to special order)
Rated System Output Power:
4000W @ -48V (2000W @ -48V. Low power option.)
Polarity:
Positive earth. (negative earth available to special order)
DC Distribution:
Load
Battery
ULTRA
compact
Load:
1x 63A load circuit breaker.
(1x 50A load circuit breaker. Low power option.)
1x 63A battery circuit breaker.
Battery:
(1x 50A battery circuit breaker. Low power option.)
Breaker Fail Detection:
Electronic fail detection on both load and battery breakers.
DC Terminals:
Tunnel terminals, 10mm².
Low Voltage Disconnect:
80A battery LVD fitted as standard.
(50A battery LVD fitted as standard. Low power option.)
Mechanical Dimensions, W, H, D:
482.6mm (standard 19” module), 44.45mm (1U, 1¾”), 350mm (13¾”)
Weight:
5kg (excluding rectifier modules)
Shipping Dimensions, W, H, D: 540mm, 95mm, 400mm
| ENATEL | 2010 PRODUCT CATALOGUE
Weight:
6kg (excluding rectifier modules)
Monitoring & Control:
Various monitoring options are available via the Enatel SM30 series of
control & supervisory modules. Standard features include full temperature
compensation, automated and manual battery testing/equalisation and
three voltage-free relay alarm outputs. Options include extension I/O PCBs
that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free
relay outputs. For further details, refer to the SM30 series of brochures.
Part Numbers:
Actual part numbers will vary with configuration.
PSC04020110-000:
1U Ultra Compact System including standard SM31 supervisory module.
PSC04020111-000:
1U Ultra Compact System including standard
SM31 supervisory module and I/O expansion card.
PSC04020120-000:
1U Ultra Compact System including standard SM32 supervisory module.
PSC04020121-000:
1U Ultra Compact System including standard
SM32 supervisory module and I/O expansion card.
PSC02020110-000:
Low Power 1U Ultra Compact System including standard
SM31 supervisory module.
PSC02020111-000:
Low Power 1U Ultra Compact System including standard
SM31 supervisory module and I/O expansion card.
PSC02020120-000:
Low Power 1U Ultra Compact System including standard
SM32 supervisory module.
PSC02020121-000:
Low Power 1U Ultra Compact System including standard
SM32 supervisory module and I/O expansion card.
1U ULTRA COMPACT SYSTEM 1.0 - 4.0kW 48V DC AC Input:
Single phase. (refer to RM series brochures for full details)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full load)
Termination:
Single phase, 6mm² L, N, E tunnel terminals.
48 4.0
V
nominal output voltage.
DC Output Nominal Voltage:
-48V, -60V (+24V available to special order)
Rated System Output Power:
4000W @ -48V (2000W @ -48V. Low power option.)
Polarity:
Positive earth. (negative earth available to special order)
DC Distribution:
Load:
Battery:
kW
3x 20A load circuit breakers.
maximum output power.
(3x 10A load circuit breakers. Low power option.) 2x 30A battery circuit breakers.
(2x 20A battery circuit breakers. Low power option.)
Breaker Fail Detection:
Electronic fail detection on both load and battery breakers.
Supervisory Module
SM32
ULTRA
compact
DC Terminals:
Live:
Common:
Tunnel terminals, 6mm² Tunnel terminals, 6mm²
Low Voltage Disconnect:
80A battery LVD fitted as standard.
(50A battery LVD fitted as standard. Low power option.)
Mechanical Dimensions, W, H, D:
482.6mm (standard 19” module), 44.45mm (1U, 1¾”), 350mm (13¾”)
Weight:
5kg (excluding rectifier modules)
Shipping Dimensions, W, H, D: 540mm, 95mm, 400mm Weight:
6kg (excluding rectifier modules)
Monitoring & Control:
Various monitoring options are available via the Enatel SM30 series of
control & supervisory modules. Standard features include full temperature
compensation, automated and manual battery testing/equalisation and
three voltage-free relay alarm outputs. Options include extension I/O PCBs
that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free
relay outputs. For further details, refer to the SM30 series of brochures.
Part Numbers:
Actual part numbers will vary with congifuration.
PSC04020110-100:
1U Ultra Compact System including standard SM31 supervisory module.
PSC04020111-100:
1U Ultra Compact System including standard SM31
supervisory module and I/O expansion card.
PSC04020120-100:
1U Ultra Compact System including standard SM32 supervisory module.
PSC04020121-100:
1U Ultra Compact System including standard SM32
supervisory module and I/O expansion card.
PSC02020110-100:
Low Power 1U Ultra Compact System including standard
SM31 supervisory module.
PSC02020111-100:
Low Power 1U Ultra Compact System including standard
SM31 supervisory module and I/O expansion card.
PSC02020120-100:
Low Power 1U Ultra Compact System including standard
SM32 supervisory module.
PSC02020121-100:
Low Power 1U Ultra Compact System including standard
SM32 supervisory module and I/O expansion card. ENATEL | 2010 PRODUCT CATALOGUE |
2U ULTRA COMPACT SYSTEM 1.0 - 6.0kW 48V DC
48 6.0 V
nominal output voltage.
maximum output power.
1 Load 2
3 Load 4
AC Input:
Three phase or single phase. (refer to RM series brochures for full details)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full load)
Termination:
Three phase, 6mm² L1, L2, L3, N, E tunnel terminals.
(Single phase by linking L1, L2, L3 terminals)
DC Output
kW
5 Load 6
Supervisory Module
SM32
Nominal Voltage:
-48V, -60V (+24V available to special order)
Rated System Output Power:
6000W @ -48V (3000W @ -48V. Low power option)
Polarity:
Positive earth. (negative earth available to special order)
DC Distribution:
1 Battery 2
ULTRA
compact
Load:
2x 10A, 2x 20A, 2x 32A load circuit breakers.
(2x 6A, 2x 10A, 2x 20A load circuit breakers. Low power option.)
2x 63A battery circuit breakers.
Battery:
(2x 63A battery circuit breakers. Low power option.)
Breaker Fail Detection:
Electronic fail detection on both load and battery breakers.
DC Terminals:
Load:
Battery:
Tunnel terminals, 16mm² (rear connected) Tunnel terminals, 35mm² (rear connected)
Low Voltage Disconnect:
125A battery LVD fitted as standard. (magnetically latching contactor)
(80A battery LVD fitted as standard. Low power option)
Mechanical Dimensions, W, H, D:
482.6mm (standard 19” module), 89mm (2U, 3½”),
350mm (13¾”) (390mm with cable strain relief)
Weight:
9kg (excluding rectifier modules)
Shipping Dimensions, W, H, D: 540mm, 150mm, 435mm
| ENATEL | 2010 PRODUCT CATALOGUE
Weight:
10.5kg (excluding rectifier modules)
Monitoring & Control:
Various monitoring options are available via the Enatel SM30 series of
control & supervisory modules. Standard features include full temperature
compensation, automated and manual battery testing/equalisation and
three voltage-free relay alarm outputs. Options include extension I/O PCBs
that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free
relay outputs. For further details, refer to the SM30 series of brochures.
Part Numbers:
Actual part numbers will vary with congifuration.
PSC06030210-000:
2U Ultra Compact System including standard SM31 supervisory module.
PSC06030211-000:
2U Ultra Compact System including standard SM31
supervisory module and I/O expansion card.
PSC06030220-000:
2U Ultra Compact System including standard SM32 supervisory module.
PSC06030221-000:
2U Ultra Compact System including standard SM32
supervisory module and I/O expansion card.
PSC03030210-000:
Low Power 2U Ultra Compact System including standard
SM31 supervisory module.
PSC03030211-000:
Low Power 2U Ultra Compact System including standard
SM31 supervisory module and I/O expansion card.
PSC03030220-000:
Low Power 2U Ultra Compact System including standard
SM32 supervisory module.
PSC03030221-000:
Low Power 2U Ultra Compact System including standard
SM32 supervisory module and I/O expansion card.
2U ULTRA COMPACT SYSTEM 1.0 - 6.0kW 48V DC AC Input:
Three phase or single phase. (refer to RM series brochures for full details)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full load)
Termination:
Three phase, 6mm² L1, L2, L3, N, E tunnel terminals.
(Single phase by linking L1, L2, L3 terminals)
48 6.0
V
nominal output voltage.
DC Output Nominal Voltage:
-48V, -60V (+24V available to special order)
Rated System Output Power:
6000W @ -48V (3000W @ -48V. Low power option.)
Polarity:
Positive earth. (negative earth available to special order)
DC Distribution:
Load:
(8x 6A, 4x 10A, 4x 20A load circuit breakers. Low power option.)
2x 100A battery circuit breakers.
Battery:
(2x 50A battery circuit breakers. Low power option.)
Breaker Fail Detection:
Electronic fail detection on both load and battery. breakers
Load:
ULTRA
compact
10A, 6mm² tunnel terminals. 20A & 30A, 10mm² tunnel terminals. (6A & 10A, 6mm² tunnel terminals.
20A, 10mm² tunnel terminals. Low power option.)
100A, 35mm² tunnel terminals.
(50A, 16mm² tunnel terminals. Low power option.)
Low Voltage Disconnect:
125A battery LVD fitted as standard.
(80A battery LVD fitted as standard. Low power option.)
1 Battery 2 SM32
Battery:
maximum output power.
Supervisory Module
DC Terminals (rear connected):
kW
8x 10A, 4x 20A, 4x 30A load circuit breakers.
Mechanical Dimensions, W, H, D:
482.6mm (standard 19” module), 89mm (2U, 3½”),
350mm (13¾”) (390mm with cable strain relief)
Weight:
9kg (excluding rectifier modules)
Shipping Dimensions, W, H, D: 540mm, 150mm, 435mm Weight:
10.5kg (excluding rectifier modules)
Monitoring & Control:
Various monitoring options are available via the Enatel SM30 series of
control & supervisory modules. Standard features include full temperature
compensation, automated and manual battery testing/equalisation and
three voltage-free relay alarm outputs. Options include extension I/O PCBs
that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free
relay outputs. For further details, refer to the SM30 series of brochures.
Part Numbers:
Actual part numbers will vary with congifuration.
PSC06030210-100:
2U Ultra Compact System including standard SM31 supervisory module.
PSC06030211-100:
2U Ultra Compact System including standard SM31
supervisory module and I/O expansion card.
PSC06030220-100:
2U Ultra Compact System including standard SM32 supervisory module.
PSC06030221-100:
2U Ultra Compact System including standard SM32
supervisory module and I/O expansion card.
PSC03030210-100:
Low Power 2U Ultra Compact System including standard
SM31 supervisory module.
PSC03030211-100:
Low Power 2U Ultra Compact System including standard
SM31 supervisory module and I/O expansion card.
PSC03030220-100:
Low Power 2U Ultra Compact System including standard
SM32 supervisory module.
PSC03030221-100:
Low Power 2U Ultra Compact System including standard
SM32 supervisory module and I/O expansion card. ENATEL | 2010 PRODUCT CATALOGUE |
2U ULTRA COMPACT SYSTEM 1.0 - 8.0kW 48V DC
48 8.0 V
nominal output voltage.
maximum output power.
AC Input:
Three phase or single phase. (refer to RM series brochures for full details)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full load)
Termination:
Three phase, 10mm² L1, L2, L3, N tunnel terminals,
16mm² E tunnel terminal. (Single phase by linking L1, L2, L3 terminals)
DC Output
kW
Nominal Voltage:
-48V, -60V (+24V available to special order)
Rated System Output Power:
8000W @ -48V
Polarity:
Positive earth. (negative earth available to special order)
DC Distribution: Supervisory Module
SM32
1 Load 2
3 Load 4
1 Battery 2
ULTRA
compact
Load:
2x 20A, 2x 63A load circuit breakers.
Battery:
2x 100A battery circuit breakers.
Breaker Fail Detection:
Electronic fail detection for load breakers.
Auxiliaries for battery MCB fail detection.
DC Terminals:
Load:
Tunnel terminals, 16mm² (rear connected)
Battery:
Tunnel terminals, 35mm² (rear connected)
Low Voltage Disconnect:
150A battery LVD fitted as standard. (magnetically latching contactor)
Mechanical Dimensions, W, H, D:
482.6mm (standard 19” module), 89mm (2U, 3½”),
350mm (13¾”) (390mm with cable strain relief)
Weight:
9kg (excluding rectifier modules)
Shipping Dimensions, W, H, D: 483mm, 88.9mm, 350mm
10 | ENATEL | 2010 PRODUCT CATALOGUE
Weight:
10.5kg (excluding rectifier modules)
Monitoring & Control:
Various monitoring options are available via the Enatel SM30 series of
control & supervisory modules. Standard features include full temperature
compensation, automated and manual battery testing/equalisation and
three voltage-free relay alarm outputs. Options include extension I/O PCBs
that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free
relay outputs. For further details, refer to the SM30 series of brochures.
Part Numbers:
Actual part numbers will vary with congifuration.
PSC08040210-000:
2U Ultra Compact System including standard SM31 supervisory module.
PSC08040211-000:
2U Ultra Compact System including standard SM31
supervisory module and I/O expansion card.
PSC08040220-000:
2U Ultra Compact System including standard SM32 supervisory module.
PSC08040221-000:
2U Ultra Compact System including standard SM32
supervisory module and I/O expansion card.
3U COMPACT SYSTEM 1.0 - 6.0kW 48V DC AC Input:
Three phase or single phase. (refer to RM series brochures for full details)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full load)
Termination:
Three phase L1, L2, L3, N, E 10mm² terminal blocks.
(Single phase by linking line terminals)
48 6.0
V
nominal output voltage.
DC Output Nominal Voltage:
-48V, -60V (+24V available to special order)
Rated System Output Power:
6000W @ -48V
Polarity:
Positive earth. (negative earth available to special order)
kW
maximum output power.
DC Distribution: 3U Compact System
Load:
1
4x 10A, 4x 20A, 4x 32A load circuit breakers.
2 3
Battery:
2x 100A battery circuit breakers.
4
5
Load
6 7 8
9
Load
10
1
11
Battery
12
2
Supervisory Module
SM32
Breaker Fail Detection:
Electronic fail detection on both load and battery breakers.
DC Terminals (rear connected):
Load:
16mm² tunnel terminals.
Battery:
35mm² tunnel terminals.
Low Voltage Disconnect:
125A battery LVD fitted as standard.
Mechanical Dimensions, W, H, D:
482.6mm (standard 19” module), 133.3mm (3U, 5¼”),
350mm (13¾”) (390mm with cable strain relief)
Weight:
11kg (excluding rectifier modules)
Shipping Dimensions, W, H, D: 540mm, 200mm, 435mm Weight:
14kg (excluding rectifier modules)
Monitoring & Control:
Various monitoring options are available via the Enatel SM30 series of
control & supervisory modules. Standard features include full temperature
compensation, automated and manual battery testing/equalisation and
three voltage-free relay alarm outputs. Options include extension I/O PCBs
that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free
relay outputs. For further details, refer to the SM30 series of brochures.
Part Numbers:
Actual part numbers will vary with congifuration.
PSC06030310-000:
3U Compact System including standard SM31 supervisory module.
PSC06030311-000:
3U Compact System including standard SM31
supervisory module and I/O expansion card.
PSC06030320-000:
3U Compact System including standard SM32 supervisory module.
PSC06030321-000:
3U Compact System including standard SM32
supervisory module and I/O expansion card. ENATEL | 2010 PRODUCT CATALOGUE | 11
3U COMPACT SYSTEM 1.0 - 6.0kW 48V DC
48 6.0 V
nominal output voltage.
maximum output power.
AC Input:
Three phase or single phase. (refer to RM series brochures for full details)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full load)
Termination:
Three phase L1, L2, L3, N, E 6mm2 terminal blocks.
(Single phase by linking line terminals)
Proctection:
20A circuit breaker provided per rectifier.
DC Output
kW
Nominal Voltage:
-48V, -60V (+24V available to special order)
Rated System Output Power:
6000W @ -48V
Polarity:
Positive earth. (negative earth available to special order)
DC Distribution: Rectifiers
AC Input
1
4
10
2
5
11
3
6
1
7
2
Load
3
Load
12 13
8
14
9
15
3U Compact System
Load
Battery
1
2
Load:
5x 10A, 4x 20A, 4x 32A load circuit breakers.
Battery:
2x 100A battery circuit breakers.
Supervisory Module
SM32
Breaker Fail Detection:
Electronic fail detection on both load and battery breakers.
DC Terminals (rear connected):
Load:
10A, 6mm² tunnel terminals.
32A, 10mm² tunnel terminals.
50A, 16mm² tunnel terminals.
35mm² tunnel terminals.
Battery:
Low Voltage Disconnect:
125A battery LVD fitted as standard.
Mechanical Dimensions, W, H, D:
482.6mm (standard 19” module), 133.3mm (3U, 5¼”),
350mm (13¾”) (390mm with cable strain relief)
Weight:
11.5kg (excluding rectifier modules)
Shipping Dimensions, W, H, D: 540mm, 200mm, 435mm
12 | ENATEL | 2010 PRODUCT CATALOGUE
Weight:
14.5kg (excluding rectifier modules)
Monitoring & Control:
Various monitoring options are available via the Enatel SM30 series of
control & supervisory modules. Standard features include full temperature
compensation, automated and manual battery testing/equalisation and
three voltage-free relay alarm outputs. Options include extension I/O PCBs
that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free
relay outputs. For further details, refer to the SM30 series of brochures.
Part Numbers:
Actual part numbers will vary with congifuration.
PSC06030310-200:
3U Compact System including standard SM31 supervisory module.
PSC06030311-200:
3U Compact System including standard SM31
supervisory module and I/O expansion card.
PSC06030320-200:
3U Compact System including standard SM32
supervisory module.
PSC06030321-200:
3U Compact System including standard SM32
supervisory module and I/O expansion card.
3U COMPACT SYSTEM 1.0 - 8.0kW 48V DC AC Input:
Three phase or single phase. (refer to RM series brochures for full details)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full load)
Termination:
Single phase L, N, E 16mm² terminal blocks
Single phase surge protection. (40KA 8/20µsec)
(Three phase without surge protection available to special order)
48 8.0
V
nominal output voltage.
DC Output Nominal Voltage:
kW
-48V, -60V (+24V available to special order)
Rated System Output Power:
8000W @ -48V
Polarity:
Positive earth. (negative earth available to special order)
maximum output power.
DC Distribution:
3U Compact System
Supervisory Module
SM32
1
Load: Battery:
Breaker Fail Detection:
2x 10A, 2x 20A, 4x 32A load circuit breakers.
2 AC Input
SPD
3
Input MCB
4
5
Load
6 7 8
1 Battery 2
2x 100A battery circuit breakers. Electronic fail detection on both load and battery breakers.
DC Terminals (rear connected):
Load:
16mm² tunnel terminals.
Battery:
35mm² tunnel terminals.
Low Voltage Disconnect:
150A battery LVD fitted as standard.
Mechanical Dimensions, W, H, D:
482.6mm (standard 19” module), 133.3mm (3U, 5¼”),
350mm (13¾”) (390mm with cable strain relief)
Weight:
11kg (excluding rectifier modules)
Shipping Dimensions, W, H, D: 483mm, 133.35mm, 350mm Weight:
11.5kg (excluding rectifier modules)
Monitoring & Control:
Various monitoring options are available via the Enatel SM30 series of
control & supervisory modules. Standard features include full temperature
compensation, automated and manual battery testing/equalisation and
three voltage-free relay alarm outputs. Options include extension I/O PCBs
that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free
relay outputs. For further details, refer to the SM30 series of brochures.
Part Numbers:
Actual part numbers will vary with congifuration.
PSC08040310-000:
3U Compact System including standard SM31 supervisory module.
PSC08040311-000:
3U Compact System including standard SM31
supervisory module and I/O expansion card.
PSC08040320-000:
3U Compact System including standard SM32
supervisory module.
PSC08040321-000:
3U Compact System including standard SM32
supervisory module and I/O expansion card. ENATEL | 2010 PRODUCT CATALOGUE | 13
5U MAXI COMPACT SYSTEM 1.0 - 14.0kW 48V DC
48 14.0 V
nominal output voltage.
Three phase (refer to RM series brochures for full details)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full load)
Termination:
Three phase L1, L2, L3, N, E 10mm² terminal blocks.
Surge protection. (40kA 8/20msec)
DC Output
kW
maximum output power.
AC Input:
Nominal Voltage:
-48V, -60V (+24V available to special order)
Rated System Output Power:
14000W @ -48V DC
Polarity:
Positive earth. (negative earth available to special order)
DC Distribution: 5U Compact System
AC Input
1
2
3
4
5
6
Load
7
8
9
Battery
10
1
Supervisory Module
SM32
2
3
4
Load:
2x 10A, 6x 32A, 2x 50A load circuit breakers.
Battery:
4x 100A battery circuit breakers.
Breaker Fail Detection:
Electronic fail detection on both load and battery breakers.
DC Terminals (rear connected):
Load:
16mm² tunnel terminals.
Battery:
35mm² tunnel terminals.
Low Voltage Disconnect:
300A battery LVD fitted as standard.
Mechanical Dimensions, W, H, D:
482.6mm (standard 19” module), 222.2mm (5U, 8¾”),
350mm (13¾”) (390mm with cable strain relief)
Weight:
14kg (excluding rectifier modules)
Shipping Dimensions, W, H, D: 540mm, 350mm, 435mm
14 | ENATEL | 2010 PRODUCT CATALOGUE
Weight:
18kg (excluding rectifier modules)
Monitoring & Control:
Various monitoring options are available via the Enatel SM30 series of
control & supervisory modules. Standard features include full temperature
compensation, automated and manual battery testing/equalisation and
three voltage-free relay alarm outputs. Options include extension I/O PCBs
that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-
free relay outputs. For further details, refer to the SM30 series of brochures.
Part Numbers:
Actual part numbers will vary with congifuration.
PSC12070510-000:
5U Maxi Compact System including standard SM31 supervisory module.
PSC12070511-000:
5U Maxi Compact System including standard SM31
supervisory module and I/O expansion card.
PSC12070520-000:
5U Maxi Compact System including standard SM32 supervisory module.
PSC12070521-000:
5U Maxi Compact System including standard SM32
supervisory module and I/O expansion card.
5U MAXI COMPACT SYSTEM 1.0 - 14.0kW 48V DC AC Input:
Three phase. (refer to RM series brochures for full details)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full load)
Termination:
Three phase L1, L2, L3, N, E 16mm² terminal blocks.
48 14.0
V
nominal output voltage.
DC Output Nominal Voltage:
-48V, -60V (+24V available to special order)
Rated System Output Power:
14000W @ -48V
Polarity:
Positive earth. (negative earth available to special order)
kW
maximum output power.
DC Distribution:
Load:
6x 10A, 4x 20A, 4x 32A, 4x 50A load circuit breakers.
Battery:
4x 100A battery circuit breakers.
Breaker Fail Detection:
Electronic fail detection on both load and battery breakers.
DC Terminals:
Load
Battery
1
2
3
4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Supervisory Module
SM32
Load:
16mm² tunnel terminals.
Battery:
35mm² tunnel terminals.
Low Voltage Disconnect:
5U Compact System
300A battery LVD fitted as standard. (option 2x LVDs)
Mechanical Dimensions, W, H, D:
482.6mm (standard 19” module), 222.2mm (5U, 8¾”),
350mm (13¾”) (390mm with cable strain relief)
Weight:
14kg (excluding rectifier modules)
Shipping Dimensions, W, H, D: 540mm, 350mm, 435mm Weight:
18kg (excluding rectifier modules)
Monitoring & Control:
Various monitoring options are available via the Enatel SM30 series of
control & supervisory modules. Standard features include full temperature
compensation, automated and manual battery testing/equalisation and
three voltage-free relay alarm outputs. Options include extension I/O PCBs
that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free
relay outputs. For further details, refer to the SM30 series of brochures.
Part Numbers:
Actual part numbers will vary with congifuration.
PSC12070510-001:
5U Maxi Compact System including standard SM31 supervisory module.
PSC12070511-001:
5U Maxi Compact System including standard SM31
supervisory module and I/O expansion card.
PSC12070520-001:
5U Maxi Compact System including standard SM32 supervisory module.
PSC12070521-001:
5U Maxi Compact System including standard SM32
supervisory module and I/O expansion card. ENATEL | 2010 PRODUCT CATALOGUE | 15
5U MAXI COMPACT SYSTEM 1.0 - 14.0kW 48V DC
48 14.0 V
nominal output voltage.
Three phase (refer to RM series brochures for full details)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full load)
Termination:
Three phase L1, L2, L3, N, E, 16mm² terminal blocks
DC Output
kW
maximum output power.
AC Input:
Nominal Voltage:
-48V, -60V (+24V available to special order)
Rated System Output Power:
14000W @ -48V
Polarity:
Positive earth (negative earth available to special order)
DC Distribution: 5U Compact System
1
AC Input
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20
Load
Supervisory Module
SM32
Battery
1
2
3
4
Load:
6x 10A, 4x 20A, 6x 32A, 4x 50A load circuit breakers
Battery:
4x 100A battery circuit breakers
Breaker Fail Detection:
Electronic fail detection on both load and battery breakers
DC Terminals:
Load:
16mm² tunnel terminals
Battery:
35mm² tunnel terminals
Low Voltage Disconnect:
300A battery LVD fitted as standard
Mechanical Dimensions, W, H, D:
482.6mm (standard 19” module), 222.2mm (5U, 8¾”),
350mm (13¾”) (390mm with cable strain relief)
Weight:
15kg (excluding rectifier modules)
Shipping Dimensions, W, H, D: 540mm, 350mm, 435mm
16 | ENATEL | 2010 PRODUCT CATALOGUE
Weight:
18kg (excluding rectifier modules)
Monitoring & Control:
Various monitoring options are available via the Enatel SM30 series of
control & supervisory modules. Standard features include full temperature
compensation, automated and manual battery testing/equalisation and
three voltage-free relay alarm outputs. Options include extension I/O PCBs
that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free
relay outputs. For further details, refer to the SM30 series of brochures.
Part Numbers:
Actual part numbers will vary with congifuration.
PSC12070510-200:
5U Maxi Compact System including standard SM31 supervisory module.
PSC12070511-200:
5U Maxi Compact System including standard SM31
supervisory module and I/O expansion card.
PSC12070520-200:
5U Maxi Compact System including standard SM32 supervisory module.
PSC12070521-200:
5U Maxi Compact System including standard SM32
supervisory module and I/O expansion card.
6U MAXI COMPACT SYSTEM 1.0 - 22.0kW 48V DC AC Input:
Three phase. (refer to RM series brochures for full details)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full load)
Termination:
Three phase L1, L2, L3, N, E 10mm² terminal blocks.
Surge protection. (40kA 8/20msec)
DC Output Nominal Voltage:
-48V, -60V (+24V available to special order)
Rated System Output Power:
22000W @ -48V DC
Polarity:
Positive earth. (negative earth available to special order)
DC Distribution:
Load:
2x 20A, 4x 32A, 4x 63A load circuit breakers.
Battery:
4x 100A battery circuit breakers.
Breaker Fail Detection:
Electronic fail detection on both load and battery breakers.
48 22.0
V
nominal output voltage.
kW
maximum output power.
6U Compact System
DC Terminals (rear connected):
AC Input
Load:
20A, 32A, 63A, 16mm² tunnel terminals.
Battery:
35mm² tunnel terminals.
Low Voltage Disconnect:
500A battery LVD fitted as standard.
1
2
3
4
5
6
Load
7
8
9
Battery
10
1
2
3
4
Supervisory Module
SM32
Mechanical Dimensions, W, H, D:
482.6mm (standard 19” module), 266.7mm (6U, 10½”),
350mm (13¾”) (390mm with cable strain relief)
Weight:
21kg (excluding rectifier modules)
Shipping Dimensions, W, H, D: 540mm, 350mm, 435mm Weight:
30kg (excluding rectifier modules)
Monitoring & Control:
Various monitoring options are available via the Enatel SM30 series of
control & supervisory modules. Standard features include full temperature
compensation, automated and manual battery testing/equalisation and
three voltage-free relay alarm outputs. Options include extension I/O PCBs
that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free
relay outputs. For further details, refer to the SM30 series of brochures.
Part Numbers:
Actual part numbers will vary with congifuration.
PSC22110610-000:
6U Maxi Compact System including standard SM31 supervisory module.
PSC22110611-000:
6U Maxi Compact System including standard SM31
supervisory module and I/O expansion card.
PSC22110620-000:
6U Maxi Compact System including standard SM32 supervisory module.
PSC22110621-000:
6U Maxi Compact System including standard SM32
supervisory module and I/O expansion card.
PSC22110610-F00:
6U Front Terminal Maxi Compact System including standard
SM31 supervisory module.*
PSC22110611-F00:
6U Front Terminal Maxi Compact System including standard
SM31 supervisory module and I/O expansion card.*
PSC22110620-F00:
6U Front Terminal Maxi Compact System including standard
SM32 supervisory module.*
PSC22110621-F00:
6U Front Terminal Maxi Compact System including standard
SM32 supervisory module and I/O expansion card.*
*for front terminal systems a minimum of 3U height above
the 6U system is recommended for load and battery cabling. ENATEL | 2010 PRODUCT CATALOGUE | 17
15U MEDIUM SYSTEM 3.0 - 27.0kW 48V DC
48 27.0
AC Input
V
nominal output voltage.
maximum output power.
kW
AC Input Range:
312-500V AC (full power output)
156-312V AC (reduced output power)
Maximum Input Current:
60A/ph (ph-N)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full power)
Style:
3-phase neutral and earth.
Surge Protection:
MOV; 3x Ph-N, 1x N-Earth.
In(8/20µS):
20kA
Imax(8/20µS):
40kA
DC Output Nominal System Output Voltage:
-48V
Maximum Power Output:
27000W
Polarity:
Positive earth. (standard)
Load & Battery Distribution:
16x load positions for 18mm wide circuit breakers,
plus 4x battery breakers up to 125A each.
May be arranged in different configurations of load and battery
Low Voltage Disconnect Options:
Single battery LVD fitted as standard.
Up to 2x LVDs with independent control may
LVD Current Rating:
breakers. Fuse options also available. (options)
be fitted on battery or load side. (option) 600A
Supervisory & Monitoring Module: SM31 (standard) SM32 TCP/IP enabled for
web based viewing & configuration. (option)
Supervisory Module Mounting:
Door mounted for improved system terminal access.
Battery Condition Monitoring:
Optional full battery monobloc monitoring.
(bloc voltage & string current)
Alarms (voltage free contacts):
1x fixed alarm - “Monitor failed”
Up to 9x user configurable, 2 of which are pre-programmed:
- Non-urgent summary alarm
- Urgent summary alarm
7x unassigned, may be assigned to any one of 37 alarm events,
(e.g. rectifier fail, mains fail etc.) on an “AND” or “OR” basis Contacts rated for 1A at 60V DC
Environmental Requirements Temperature:
-10°C to +70°C (max. power de-rated above 50°C)
Humidity:
5-95% RH (non-condensing)
Altitude:
<2500m, De-rate maximum ambient temperature
by 4°C per 1000m above sea level.
Mechanical Dimensions W, D, H:
600mm (23 ½”) , 19” standard mounting rails 450mm (17 ¾”),
800mm (31 ½”) providing 15U of rack space.
Weight:
75kg (approx)
Shipping Size L, W, H
900mm x 700mm x 550mm
Shipping weight:
80kg (approx)
Compliances
18 | ENATEL | 2010 PRODUCT CATALOGUE
Safety:
EN60950
Part Numbers:
Actual part numbers will vary with congifuration.
Contact us for further details on a solution that suits your requirements.
1.6M MEDIUM SYSTEM 3.0 - 27.0kW 48V DC AC Input AC Input Range:
312-500V AC (full power output)
156-312V AC (reduced output power)
Maximum Input Current:
54A/ph (ph-N)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full power)
Style:
3-phase neutral and earth.
Surge Protection:
MOV; 3x Ph-N, 1x N-Earth. (spark gap)
In(8/20µS):
20kA
Imax(8/20µS):
40kA
48 27.0
V
nominal output voltage.
kW
DC Output Nominal System Output Voltage:
-48V
Maximum Power Output:
27000W
Polarity:
Positive earth. (standard)
maximum output power.
Load Distribution:
Priority:
6x 18mm MCBs.
Non-Priority:
5x 18mm MCBs, 2x 100A DIN00 fuses, 2x 160A DIN00 fuses.
Battery Distribution:
2x 400A DIN02 fuses.
LVD Options:
2x LVDs with independent control on load side.
LVD Rating:
Priority:
400A
Non-Priority:
200A
Supervisory & Monitoring Module: SM31 (standard) SM32 TCP/IP enabled for
Supervisory Module Mounting:
web based viewing & configuration. (option) Door mounted for improved system terminal access.
Battery Condition Monitoring:
Optional full battery monobloc monitoring.
(bloc voltage & string current)
Alarms (voltage free contacts):
1x fixed alarm – “Monitor failed”
Up to 9x user configurable, 2 of which are pre-programmed:
- Non-urgent summary alarm
- Urgent summary alarm
7x unassigned, may be assigned to any one of 37 alarm events,
(e.g. rectifier fail, mains fail etc.) on an “AND” or “OR” basis.
Contacts rated for 1A at 60V DC
Environmental Requirements Temperature:
-10°C to +70°C (max. power de-rated above 50°C)
Humidity:
5-95% RH (non-condensing)
Altitude:
<2500m, De-rate maximum ambient temperature
by 4°C per 1000m above sea level.
Mechanical Dimensions W, D, H:
600mm (23.6”), 600mm (23.6”), 1600mm (63”),
providing 33U of rack space.
Weight:
120kg (approx)
Shipping Size L, W, H
1700mm x 720mm x 830mm
Shipping weight:
130kg (approx)
Compliances Safety:
EN60950
Part Numbers:
Actual part numbers will vary with congifuration.
Contact us for further details on a solution that suits your requirements. ENATEL | 2010 PRODUCT CATALOGUE | 19
2.0M MEDIUM SYSTEM 3.0 - 54.0kW 48V DC
48 54.0 V
nominal output voltage.
maximum output power.
kW
AC Input Voltage Range:
312-500V AC (full power output)
156-312V AC (reduced output power)
Maximum Input Current:
120A/ph (ph-N)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full power)
Style:
3-phase neutral and earth.
Surge Protection:
MOV; 3x Ph-N, 1x N-Earth.
In(8/20µS):
20kA
Imax(8/20µS):
40kA
DC Output Nominal System Output Voltage:
-48V
Maximum Power Output:
54000W
Polarity:
Positive earth. (standard)
Load & Battery Distribution:
56x positions for 18mm wide DIN rail mount circuit breakers.
May be arranged in many configurations of loads and batteries.
Fuse options also available. (options)
Low Voltage Disconnect Options:
Single battery LVD fitted as standard.
Up to 2x LVDs with independent control
may be fitted on battery or load side. (option)
LVD Current Rating:
1200A
Supervisory & Monitoring Module: SM31 (standard) SM32 TCP/IP enabled
for web based viewing & configuration. (option)
Supervisory Module Mounting:
Door mounted for improved system terminal access.
Battery Condition Monitoring:
Optional full battery monobloc monitoring.
(bloc voltage & string current)
Alarms (voltage free contacts):
1x fixed alarm – “Monitor failed”
Up to 9x user configurable, 2 of which are pre-programmed:
- Non-urgent summary alarm
- Urgent summary alarm
7x unassigned, may be assigned to any one of 37 alarm events,
(e.g. rectifier fail, mains fail etc.) on an “AND” or “OR” basis
Contacts rated for 1A at 60V DC
Environmental Requirements Temperature:
-10°C to +70°C (max. power de-rated above 50°C)
Humidity:
5-95% RH (non-condensing)
Altitude:
<2500m, De-rate maximum ambient temperature
by 4°C per 1000m above sea level.
Mechanical Dimensions W, D, H:
600mm (23.6”), 19” standard mounting rails, 600mm (23.6”),
2000mm (78 ¾”) 40U of rack space.
Weight:
180kg (approx)
Shipping Size L, W, H
2100mm, 720mm, 830mm
Shipping weight:
195kg (approx)
Compliances
20 | ENATEL | 2010 PRODUCT CATALOGUE
Safety:
EN60950
Part Numbers:
Actual part numbers will vary with congifuration.
Contact us for further details on a solution that suits your requirements.
2.2M INTEGRATED BASE TRANSCEIVER STATION SYSTEM 1.0 - 16.0kW 48V DC AC Input AC Input Range:
312-500V AC (full power output)
156-312V AC (reduced output power)
Maximum Input Current:
36A/ph (ph-N)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full power)
Style:
3-phase neutral and earth.
Surge Protection:
MOV; 3x Ph-N, 1x N-Earth. (spark gap)
In(8/20µS):
20kA
Imax(8/20µS):
40kA
48 16.0
V
nominal output voltage.
kW
maximum output power.
DC Output Nominal System Output Voltage:
-48V
Maximum Power Output:
16000W
Polarity:
Positive earth. (standard)
Load & Battery Distribution:
24x load positions for 18mm wide circuit breakers, plus 3x battery
breakers up to 100A each. May be arranged in different
configurations of load and battery breakers. (option)
Low Voltage Disconnect Options:
Single battery LVD fitted as standard. Up to 2x LVDs with
independent control may be fitted on load side. (option)
LVD Current Rating:
400A
Supervisory & Monitoring Module: SM31 (standard) SM32 TCP/IP enabled
for web based viewing & configuration. (option)
Supervisory Module Mounting:
Door mounted for improved system terminal access.
Rectifier Modules:
RM2048, 48V 2.0kW module.
Environmental Requirements Temperature:
-10°C to +70°C (max. power de-rated above 50°C)
Humidity:
5-95% RH (non-condensing)
Altitude:
<2500m, De-rate maximum ambient temperature
by 4°C per 1000m above sea level.
Mechanical Dimensions W, D, H:
600mm (23.6”), 600mm (23.6”),2200mm (86.6”)
Weight:
1000kg when fitted with 4x strings of 180Ahr batteries. (approx)
Shipping Size L, W, H
2400mm x 720mm x 830mm
Shipping weight:
180kg (no batteries fitted, approx)
Battery Accommodation Battery Trays:
Up to 4x 180Ahr monoblocs of up to 60kg each per tray.
(max. of 250kg per tray)
Battery Monobloc Size W, D, H:
110mm, 555mm, 288mm
Compliances Safety:
EN60950
Part Numbers:
Actual part numbers will vary with congifuration.
Contact us for further details on a solution that suits your requirements. ENATEL | 2010 PRODUCT CATALOGUE | 21
2.0M LARGE DATA CENTER SOLUTIONS
48 54.0 V
nominal output voltage.
scalable output power.
kW
AC Input Voltage Range:
312-500V AC (full power output)
156-312V AC (reduced output power)
Maximum Input Current:
120A/ph (ph-N)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full power)
Style:
3-phase neutral and earth.
Surge Protection:
MOV; 3x Ph-N, 1x N-Earth.
In(8/20µS):
20kA
Imax(8/20µS):
40kA
DC Output Nominal System Output Voltage:
-48V
Maximum Power Output:
From 54000W scalable to over 300kW.
Polarity:
Positive earth. (standard) Load & Battery Distribution:
56x positions for 18mm wide
DIN rail mount circuit breakers.
May be arranged in many
configurations of loads and
batteries. Fuse options also
available. (options)
LVD Options:
Single battery LVD.
Up to 2x LVDs with independent
control may be fitted on battery
or load side. (option)
LVD Current Rating:
1200A
Monitoring:
SM31 (standard) SM32 TCP/IP
enabled for web based viewing
& configuration. (option)
Supervisory Module Mounting: Door mounted for improved
system terminal access.
Battery Condition Monitoring: Optional full battery monobloc
monitoring. (bloc voltage &
string current)
Environmental Requirements Temperature:
-10°C to +70°C (max. power
de-rated above 50°C)
Humidity:
5-95% RH (non-condensing)
Altitude:
<2500m, De-rate maximum
ambient temperature by 4°C
per 1000m above sea level.
Mechanical Dimensions W, D, H:
600mm (23.6”), 19” standard
mounting rails, 600mm (23.6”),
2000mm (78 ¾”)
40U of rack space.
Weight:
180kg (approx)
Shipping Size L, W, H
2100mm, 720mm, 830mm
Shipping weight:
195kg (approx)
Compliances Safety:
EN60950
Part Numbers: Actual part numbers will vary with congifuration.
22 | ENATEL | 2010 PRODUCT CATALOGUE
Contact us for further details on a solution that
suits your requirements.
WALL MOUNT SYSTEM 4.0kW 48V DC / 2.1kW 24V DC AC Input:
Single phase with surge protection and input 32A MCB (refer to rectifier brochure for full details)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full load)
Termination:
Single phase. Direct MCB termination for L. 10mm² N, E tunnel
V
terminals. DC Output Nominal Voltages:
-48V version.
+24V version.
Max Rated System Output Power:
4000W @ -48V DC, 83A max.
2140W @ +24V DC, 80A max.
Polarity:
Positive earth.
Negative Earth.
1x RM3048 3000W rectifier or
1x RM2324 2140W rectifier or
2x RM2048 2000W rectifiers.
2x RM1848/24 900W rectifiers.
DC Distribution:
Load:
Max 8x 18mm MCB load circuit breakers.
Battery:
Max 2x 18mm MCB load circuit breakers.
Breaker Fail Detection:
Electronic fuse fail. (Auxiliaries optional)
DC Terminals:
Live: Direct MCB connections.
Load:
Common: 16mm tunnel terminals.
Battery:
Common: 35mm tunnel terminals.
48 4.0 24 2.1
Low Voltage Disconnect:
80A battery LVD fitted as standard on -48V and 24V systems.
Weight:
Approx. 10.5Kg
Dimensions (L, H,W):
620mm x 375mm x 80mm
Shipping Dimensions (L, H,W):
730mm x 470mm x 200mm
Monitoring and Control:
Various monitoring options via the Enatel SM30 series of control
& supervisory modules. Standard features include full temperature
compensation, automated and manual battery testing/equalisation
and three voltage-free relay alarm outputs. Options include extension
remote I/O PCBs that give an extra 6x digital inputs, 6x analogue
inputs and 8x voltage-free relay outputs. For further details,
refer to the SM30 series of brochures.
Part Numbers:
Actual part numbers will vary with congifuration.
PSW-4204810-000:
48V, 2x 2000W rectifiers, SM31 supervisory module.
PSW-4204820-000:
48V, 2x 2000W rectifiers, SM32 supervisory module.
(Remote communication via SNMP)
PSW-3104810-000:
48V, 1x 3000W rectifier, SM31 supervisory module.
PSW-3104820-000:
48V, 1x 3000W rectifier, SM32 supervisory module.
(Remote communication via SNMP)
PSW-2102410-000:
24V, 1x 2140W rectifier, SM31 supervisory module.
PSW-2102420-000:
24V, 1x 2140W rectifier, SM32 supervisory module.
(Remote communications via SNMP)
PSW-2202410-000:
24V, 2x 900W rectifiers, SM31 supervisory module.
PSW-2202420-000:
24V, 2x 900W rectifiers, SM32 supervisory module.
(Remote communication via SNMP)
nominal output voltage.
kW
maximum output power.
V
nominal output voltage.
kW
maximum output power.
ENATEL | 2010 PRODUCT CATALOGUE | 23
MODULAR RECTIFIERS - Force cooled.
If you are looking for modular, plug and play rectifiers with some of the highest
- Microprocessor controlled.
power densities in the market you have come to the right place.
- Power factor corrected. - Thermally protected.
These rectifiers are designed for integration into systems that require intelligent
- Input/output voltage
features and remote control. With efficiencies in excess of 92% and power
and current protected.
- Serial alarm and control interface.
factors of greater than 0.98 these rectifiers will save operating costs, and reduce heat dissipation. Suitable for powering a wide range of telecommunications and data networking applications including wireless, access networks and central office switching environments.
24 | ENATEL | 2010 PRODUCT CATALOGUE
RM3048 3.0kW 48V DC MODULAR RECTIFIER AC Input Nominal:
230V
Voltage Range:
90-300V (reduced power below 175V)
Frequency Range:
45-65 Hz
Power Factor:
>0.99
Efficiency:
>92% (>45% output power)
Input Fuses:
HRC fuses in phase and neutral.
Maximum Input Current:
19A
Protection:
Input Voltage:
Auto shutdown, auto restart when correct voltage restored.
Input Inrush:
<2x maximum input current.
48 3.0 60.0
V
nominal output voltage.
kW
DC Output Output Ratings:
Constant power output from 50V to 58V
Nominal Voltage:
48V
Rated Voltage:
58V
Voltage Range:
43-60V
Maximum Current:
60A
Regulation:
Line:
±0.1%
Load:
±0.5% (no load to full load)
Hold-up Time:
>15ms for 20% output voltage drop.
Start-up Time:
Start up delay 1 second. (varies with AC supply voltage)
Walk-in delay 6 seconds at full output. (varies with DC output voltage)
nominal output power.
A
maximum output current.
Protection:
Current Limit:
Adjustable to 50-100% of maximum rated current.
Over Temperature:
Automatic current turndown, backup shutdown protection.
Polarity Reversal:
Output fuse with crowbar diode.
Over voltage:
Adjustable limit.
Noise: (under nominal conditions)
Ripple <100Hz:
<1mV rms unweighted
Voice band 100Hz-5KHz:
<1mV rms psophometric
Wide band 5kHz-1MHz:
<5mV rms unweighted
Peak to Peak 0-20MHz:
<50mV peak to peak
Isolation:
Input to Output:
4000V DC
Input to Chassis:
3500V DC (VDR to chassis removed)
Output to Chassis:
2100V DC
Environmental Requirements Ambient Temperature:
Nominal:
25+/-5ºC
Range:
-10ºC to +70ºC (maximum output power is derated above +50ºC)
Storage Temperature:
-20ºC to +70ºC
Humidity:
5-95% RH (non-condensing)
Altitude:
<2500m, De-rate maximum ambient temperature by 4ºC per 1000m above sea level.
Mechanical Dimensions, W, H, D:
41mm, 220mm, 305mm overall.
Weight:
2.7kg
Shipping Dimensions W, H, D:
52mm, 230mm, 340mm
Shipping Weight:
2.85kg
Cooling:
Forced cooled, using dual temperature controlled high reliability fans.
Compliances Safety:
EN60950
Electrostatic Discharge:
CISPR24
Radiated Radio Frequency:
CISPR22
AC Harmonics:
EN61000-3-2
AC Flicker and Fluctuation:
EN61000-3-3
Other:
CE & RoHS compliant. ENATEL | 2010 PRODUCT CATALOGUE | 25
RM3048/24 3.0kW 48V DC / 1.7kW 24V DC MODULAR RECTIFIER
48 3.0 24 1.7 60.0
AC Input
V
nominal output voltage.
nominal output power.
kW
90-300V (reduced power below 175V)
Frequency Range:
45-65 Hz
Power Factor:
>0.99
Efficiency:
>92% (>45% output power)
Input Fuses:
HRC fuses in phase and neutral.
Maximum Input Current:
19A
Input Voltage:
Auto shutdown, auto restart when correct voltage restored.
Input Inrush:
<2x maximum input current.
DC Output - Software Switchable
48V
24V
Output Ratings:
Constant power output from 50V to 60V
Current limited to 60A
Nominal Voltage:
48V
24V
Rated Voltage:
58V
29V
Voltage Range:
43-60V
21-30V
Maximum Current:
60A
60A
Regulation:
nominal output voltage.
Line:
±0.1%
Load:
±0.5% (no load to full load)
Hold-up Time:
>15ms for 20% output voltage drop.
Start-up Time:
Start up delay 1 second. (varies with AC supply voltage)
Walk-in delay 6 seconds at full output. (varies with DC output voltage)
Protection:
kW
maximum output current.
230V
Voltage Range:
Protection:
V
nominal output power.
Nominal:
Current Limit:
Adjustable to 50-100% of maximum rated current.
Over Temperature:
Automatic current turndown, backup shutdown protection.
Polarity Reversal:
Output fuse with crowbar diode.
Over voltage:
Adjustable limit.
Noise: (under nominal conditions)
Ripple <100Hz:
<1mV rms unweighted
Voice band 100Hz-5KHz:
<1mV rms psophometric
Wide band 5kHz-1MHz:
<5mV rms unweighted
Peak to Peak 0-20MHz:
<50mV peak to peak
Isolation:
A
Input to Output:
4000V DC
Input to Chassis:
3500V DC (VDR to chassis removed)
Output to Chassis:
2100V DC
Environmental Requirements Ambient Temperature:
Nominal:
25+/-5ºC
Range:
-10ºC to +70ºC (maximum output power is derated above +50ºC)
Storage Temperature:
-20ºC to +70ºC
Humidity:
5-95% RH (non-condensing)
Altitude:
<2500m, De-rate maximum ambient
temperature by 4ºC per 1000m above sea level.
Mechanical Dimensions, W, H, D:
41mm, 220mm, 305mm overall.
Weight:
2.7kg
Shipping Dimensions W, H, D:
52mm, 230mm, 340mm
Shipping Weight:
2.85kg
Cooling:
Forced cooled, using dual temperature controlled high reliability fans.
Compliances
26 | ENATEL | 2010 PRODUCT CATALOGUE
Safety:
EN60950
Electrostatic Discharge:
CISPR24
Radiated Radio Frequency:
CISPR22
AC Harmonics:
EN61000-3-2
AC Flicker and Fluctuation:
EN61000-3-3
Other:
CE & RoHS compliant.
RM3060/48 3.0kW 60/48V DC MODULAR RECTIFIER AC Input Nominal:
230V
Voltage Range:
90-300V (reduced power below 175V)
Frequency Range:
45-65 Hz
Power Factor:
>0.99
Efficiency:
>92% (>45% output power)
Input Fuses:
HRC fuses in phase and neutral.
Maximum Input Current:
19A
60/48 3.0 50.0
Protection:
Input Voltage:
Auto shutdown, auto restart when correct voltage restored.
Input Inrush:
<2x maximum input current.
DC Output - Software Switchable
60V
48V
Output Ratings:
Constant power output from 60V to 74V
Current limited to 50A
Nominal Voltage:
60V
48V
Rated Voltage:
68V
58V
Voltage Range:
52-74V
43-60V
Maximum Current:
50A
50A
Regulation:
Line:
±0.1%
Load:
±0.5% (no load to full load)
V
nominal output voltage.
Hold-up Time:
>15ms for 20% output voltage drop
Start-up Time:
Start up delay 1 second. (varies with AC supply voltage)
Walk-in delay 6 seconds at full output. (varies with DC output voltage)
kW
nominal output power.
A
maximum output current.
Protection:
Current Limit:
Adjustable to 50-100% of maximum rated current.
Over Temperature:
Automatic current turndown, backup shutdown protection.
Polarity Reversal:
Output fuse with crowbar diode.
Over voltage:
Adjustable limit.
Noise: (under nominal conditions)
Ripple <100Hz:
<1mV rms unweighted
Voice band 100Hz-5KHz:
<1mV rms psophometric
Wide band 5kHz-1MHz:
<5mV rms unweighted
Peak to Peak 0-20MHz:
<50mV peak to peak
Isolation:
Input to Output:
4000V DC
Input to Chassis:
3500V DC (VDR to chassis removed)
Output to Chassis:
2100V DC
Environmental Requirements Ambient Temperature:
Nominal:
25+/-5ºC
Range:
-20ºC to +70ºC (maximum output power is derated above +50ºC)
Storage Temperature:
-20ºC to +70ºC
Humidity:
5-95% RH (non-condensing)
Altitude:
<2500m, De-rate maximum ambient temperature
by 4ºC per 1000m above sea level.
Mechanical Dimensions, W, H, D:
41mm, 220mm, 305mm overall.
Weight:
2.8kg
Shipping Dimensions W, H, D:
52mm, 230mm, 340mm
Shipping Weight:
2.95kg
Cooling:
Forced cooled, using dual temperature controlled high reliability fans.
Compliances Safety:
EN60950
Electrostatic Discharge:
CISPR24
Radiated Radio Frequency:
CISPR22
AC Harmonics:
EN61000-3-2
AC Flicker and Fluctuation:
EN61000-3-3
Other:
CE & RoHS compliant. ENATEL | 2010 PRODUCT CATALOGUE | 27
RM2324 2.3kW 24V DC MODULAR RECTIFIER
24 2.3 80.0
AC Input
V
nominal output voltage.
nominal output power.
230V
Voltage Range:
90-300V (reduced power below 150V)
Frequency Range:
45-65 Hz
Power Factor:
>0.99
Efficiency:
>91% (>45% output power)
Input Fuses:
HRC fuses in phase and neutral.
Maximum Input Current:
19A
Protection:
kW
maximum output current.
Nominal:
Input Voltage:
Auto shutdown, auto restart when correct voltage restored.
Input Inrush:
<2x maximum input current.
DC Output Output Ratings:
Current limited to 80A
Nominal Voltage:
24V
Rated Voltage:
29V
Voltage Range:
21-30V
Maximum Current:
80A
Regulation:
A
Line: ±0.1%
Load: ±0.5% (no load to full load)
Hold-up Time:
>15ms for 20% output voltage drop.
Start-up Time:
Start up delay 1 second. (varies with AC supply voltage)
Walk-in delay 7 seconds at full output. (varies with DC output voltage)
Protection:
Current Limit:
Adjustable to 50-100% of maximum rated current.
Over Temperature:
Automatic current turndown, backup shutdown protection.
Polarity Reversal:
Output fuse with crowbar diode.
Over voltage:
Adjustable limit.
Noise: (under nominal conditions)
Ripple <100Hz:
<1mV rms unweighted
Voice band 100Hz-5KHz:
<1mV rms psophometric
Wide band 5kHz-1MHz:
<5mV rms unweighted
Peak to Peak 0-20MHz:
<50mV peak to peak
Isolation:
Input to Output:
4000V DC
Input to Chassis:
3500V DC (VDR to chassis removed)
Output to Chassis:
2100V DC
Environmental Requirements Ambient Temperature:
Nominal:
25+/-5ºC
Range:
-10ºC to +70ºC (maximum output power is derated above +50ºC)
Storage Temperature:
-20ºC to +70ºC
Humidity:
5-95% RH (non-condensing)
Altitude:
<2500m, De-rate maximum ambient temperature
by 4ºC per 1000m above sea level.
Mechanical Dimensions, W, H, D:
41mm, 220mm, 305mm overall.
Weight:
2.7kg
Shipping Dimensions W, H, D:
52mm, 230mm, 340mm
Shipping Weight:
2.75kg
Cooling:
Forced cooled, using dual temperature controlled high reliability fans.
Compliances
28 | ENATEL | 2010 PRODUCT CATALOGUE
Safety:
EN60950
Electrostatic Discharge:
CISPR24
Radiated Radio Frequency:
CISPR22
AC Harmonics:
EN61000-3-2
AC Flicker and Fluctuation:
EN61000-3-3
Other:
CE & RoHS compliant.
RM2048XP 2.0KW 48V DC MODULAR RECTIFIER AC Input Nominal:
230V
Voltage Range:
90-300V (reduced power below 175V)
Frequency Range:
45-65 Hz
Power Factor:
>0.99
Efficiency:
>92% (>50% output power)
Total Harmonic Distortion (THD):
<5% (>30% output power)
Input Fuses:
HRC fuses in phase and neutral.
Maximum Input Current:
12A
Protection:
Input Voltage:
Auto shutdown, auto restart when correct voltage restored.
Input Inrush:
<12A rms
DC Output Output Ratings:
Constant power output from 48V to 58V
Nominal Voltage:
48V
Rated Voltage:
58V
Voltage Range:
43-60V
Maximum Current:
41.7A
Regulation:
Line:
±0.1%
Load:
±0.5% (no load to full load)
Hold-up Time:
>15ms for 20% output voltage drop.
Start-up Time:
Start up delay 1 second. (varies with AC supply voltage)
Walk-in delay 6 seconds at full output. (varies with DC output voltage)
48 2.0 41.7
V
nominal output voltage.
kW
nominal output power.
A
maximum output current.
Protection:
Current Limit:
Adjustable to 50-100% of maximum rated current.
Over Temperature:
Automatic current turndown, backup shutdown protection.
Polarity Reversal:
Output fuse with crowbar diode.
Over voltage:
Adjustable limit.
Noise: (under nominal conditions)
Ripple <100Hz:
<1mV rms unweighted
Voice band 100Hz-5KHz:
<1mV rms psophometric
Wide band 5kHz-1MHz:
<5mV rms unweighted
Peak to Peak 0-20MHz: Isolation: Input to Output: Input to Chassis:
<100mV peak to peak
2100V DC
Output to Chassis:
4000V DC 3500V DC (VDR to chassis removed)
Environmental Requirements Ambient Temperature:
Nominal:
25+/-5ºC
Range:
-10ºC to +70ºC (maximum output power is derated above +50ºC)
Storage Temperature:
-20ºC to +70ºC
Humidity:
5-95% RH (non-condensing)
Altitude:
<2500m, De-rate maximum ambient temperature
by 4ºC per 1000m above sea level.
Mechanical Dimensions, W, H, D:
111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)
Weight:
1.5kg
Shipping Dimensions W, H, D:
120mm, 52mm, 325mm
Shipping Weight:
1.6kg
Cooling:
Forced cooled.
Compliances Safety:
EN60950
Electrostatic Discharge:
CISPR24
Radiated Radio Frequency:
CISPR22
AC Harmonics:
EN61000-3-2
AC Flicker and Fluctuation:
EN61000-3-3
Other:
CE & RoHS compliant. ENATEL | 2010 PRODUCT CATALOGUE | 29
RM2048/24 2.0kW 48V DC / 1.0kW 24V DC MODULAR RECTIFIER
48 2.0 24 1.0 41.7
AC Input
V
nominal output voltage.
nominal output power.
90-300V (reduced power below 175V)
Frequency Range:
45-65 Hz
Power Factor:
>0.99
Efficiency:
>91% (>50% output power)
Input Fuses:
HRC fuses in phase and neutral.
Maximum Input Current:
13A
Input Voltage:
Auto shutdown, auto restart when correct voltage restored.
Input Inrush:
<2x maximum input current.
DC Output - Software Switchable
48V
24V
Output Ratings:
Constant power output from 54V to 60V
Current limited to 41.7A
Nominal Voltage:
48V
24V
Rated Voltage:
58V
29V
Voltage Range:
43-60V
21-30V
Maximum Current:
41.7A
41.7A
Regulation:
V
nominal output voltage.
Line:
±0.1%
Load:
±0.5% (no load to full load)
Hold-up Time:
>15ms for 20% output voltage drop.
Start-up Time:
Start up delay 1 second. (varies with AC supply voltage)
Walk-in delay 6 seconds at full output. (varies with DC output voltage)
Protection:
kW
maximum output current.
230V
Voltage Range:
Protection:
kW
nominal output power.
Nominal:
Current Limit:
Adjustable to 50-100% of maximum rated current.
Over Temperature:
Automatic current turndown, backup shutdown protection.
Polarity Reversal:
Output fuse with crowbar diode.
Over voltage:
Adjustable limit.
Noise: (under nominal conditions)
Ripple <100Hz:
<1mV rms unweighted
Voice band 100Hz-5KHz:
<1mV rms psophometric
Wide band 5kHz-1MHz:
<5mV rms unweighted
Peak to Peak 0-20MHz:
<50mV peak to peak
Isolation:
A
Input to Output:
4000V DC
Input to Chassis:
3500V DC (VDR to chassis removed)
Output to Chassis:
2100V DC
Environmental Requirements Ambient Temperature:
Nominal:
25+/-5ºC
Range:
-10ºC to +70ºC (maximum output power is derated above +50ºC)
Storage Temperature:
-20ºC to +70ºC
Humidity:
5-95% RH (non-condensing)
Altitude:
<2500m, De-rate maximum ambient temperature
by 4ºC per 1000m above sea level.
Mechanical Dimensions, W, H, D:
111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)
Weight:
1.5kg
Shipping Dimensions W, H, D:
120mm, 52mm, 325mm
Shipping Weight:
1.6kg
Cooling:
Forced cooled.
Compliances
30 | ENATEL | 2010 PRODUCT CATALOGUE
Safety:
EN60950
Electrostatic Discharge:
CISPR24
Radiated Radio Frequency:
CISPR22
AC Harmonics:
EN61000-3-2
AC Flicker and Fluctuation:
EN61000-3-3
Other:
CE & RoHS compliant.
RM1860/48 1.8kW 60/48V DC MODULAR RECTIFIER AC Input Nominal:
230V
Voltage Range:
90-300V (reduced power below 175V)
Frequency Range:
45-65 Hz
Power Factor:
>0.99
Efficiency:
>91% (>50% output power)
Input Fuses:
HRC fuses in phase and neutral.
Maximum Input Current:
11A
60/48 1.8 30.0
Protection:
Input Voltage:
Auto shutdown, auto restart when correct voltage restored.
Input Inrush:
<2x maximum input current.
DC Output - Software Switchable
60V
48V
Output Ratings:
Constant power output from 60V to 74V
Current limited to 30A
Nominal Voltage:
60V
48V
Rated Voltage:
68V
54V
Voltage Range:
52-74V
43-60V
Maximum Current:
30A
30A
Regulation:
Line:
±0.1%
Load:
±0.5% (no load to full load)
V
nominal output voltage.
Hold-up Time:
>15ms for 20% output voltage drop
Start-up Time:
Start up delay 1 second. (varies with AC supply voltage)
Walk-in delay 6 seconds at full output. (varies with DC output voltage)
kW
nominal output power.
A
maximum output current.
Protection:
Current Limit:
Adjustable to 50-100% of maximum rated current.
Over Temperature:
Automatic current turndown, backup shutdown protection.
Polarity Reversal:
Output fuse with crowbar diode.
Over voltage:
Adjustable limit.
Noise: (under nominal conditions)
Ripple <100Hz:
<1mV rms unweighted
Voice band 100Hz-5KHz:
<1mV rms psophometric
Wide band 5kHz-1MHz:
<5mV rms unweighted
Peak to Peak 0-20MHz:
<50mV peak to peak
Isolation:
Input to Output:
4000V DC
Input to Chassis:
3500V DC (VDR to chassis removed)
Output to Chassis:
2100V DC
Environmental Requirements Ambient Temperature:
Nominal:
25+/-5ºC
Range:
-10ºC to +70ºC (maximum output power is derated above +50ºC)
Storage Temperature:
-20ºC to +70ºC
Humidity:
5-95% RH (non-condensing)
Altitude:
<2500m, De-rate maximum ambient temperature
by 4ºC per 1000m above sea level.
Mechanical Dimensions, W, H, D:
111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)
Weight:
1.4kg
Shipping Dimensions W, H, D:
120mm, 52mm, 325mm
Shipping Weight:
1.5kg
Cooling:
Forced cooled.
Compliances Safety:
EN60950
Electrostatic Discharge:
CISPR24
Radiated Radio Frequency:
CISPR22
AC Harmonics:
EN61000-3-2
AC Flicker and Fluctuation:
EN61000-3-3
Other:
CE & RoHS compliant. ENATEL | 2010 PRODUCT CATALOGUE | 31
RM1048 1.0kW 48V DC MODULAR RECTIFIER
48 1.0 21.0 V
nominal output voltage.
nominal output power.
kW
maximum output current.
A
AC Input Nominal:
230V
Voltage Range:
90-300V (reduced power below 175V)
Frequency Range:
45-65 Hz
Power Factor:
>0.99
Efficiency:
>90% (>50% output power)
Input Fuses:
HRC fuses in phase and neutral.
Protection:
Input Voltage:
Input Inrush:
Maximum Input Current:
Auto shutdown, auto restart when correct voltage restored. <2x maximum input current. 7A
DC Output Output Ratings:
Constant power output from 48V to 58V
Nominal Voltage:
48V
Rated Voltage:
58V
Voltage Range:
43-60V
Maximum Current:
21A
Regulation:
Line:
±0.1%
Load:
±0.5% (no load to full load)
Hold-up Time:
>15ms for 20% output voltage drop.
Start-up Time:
Start up delay 1 second. (varies with AC supply voltage)
Walk-in delay 6 seconds at full output. (varies with DC output voltage)
Protection:
Current Limit:
Adjustable to 50-100% of maximum rated current.
Over Temperature:
Automatic current turndown, backup shutdown protection.
Polarity Reversal:
Output fuse with crowbar diode.
Over voltage:
Adjustable limit.
Noise: (under nominal conditions)
Ripple <100Hz:
<1mV rms unweighted
Voice band 100Hz-5KHz:
<1mV rms psophometric
Wide band 5kHz-1MHz:
<5mV rms unweighted
Peak to Peak 0-20MHz:
<50mV peak to peak
Isolation:
Input to Output:
4000V DC
Input to Chassis:
3500V DC (VDR to chassis removed)
Output to Chassis:
2100V DC
Environmental Requirements Ambient Temperature:
Nominal:
25+/-5ºC
Range:
-10ºC to +75ºC (maximum output power is derated above +50ºC)
Storage Temperature:
-20ºC to +75ºC
Humidity:
5-95% RH (non-condensing)
Altitude:
<2500m, De-rate maximum ambient temperature
by 4ºC per 1000m above sea level.
Mechanical Dimensions, W, H, D:
111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)
Weight:
1.4kg
Shipping Dimensions W, H, D:
120mm, 52mm, 325mm
Shipping Weight:
1.5kg
Cooling:
Forced cooled
Compliances
32 | ENATEL | 2010 PRODUCT CATALOGUE
Safety:
EN60950
Electrostatic Discharge:
CISPR24
Radiated Radio Frequency:
CISPR22
AC Harmonics:
EN61000-3-2
AC Flicker and Fluctuation:
EN61000-3-3
Other:
CE & RoHS compliant.
RM848 800W 48V DC MODULAR RECTIFIER AC Input Nominal:
230V
Voltage Range:
90-300V (reduced power below 175V)
Frequency Range:
45-65 Hz
Power Factor:
>0.99
Efficiency:
>92% (>50% output power)
Input Fuses:
HRC fuses in phase and neutral.
Maximum Input Current:
5.5A
Protection:
Input Voltage:
Auto shutdown, auto restart when correct voltage restored.
Input Inrush:
<2x maximum input current.
DC Output Output Ratings:
Constant power output from 54V to 58V
Nominal Voltage:
48V
Rated Voltage:
58V
Voltage Range:
43-60V
Maximum Current:
16.6A
Regulation:
Line:
±0.1%
Load:
±0.5% (no load to full load)
Hold-up Time:
>15ms for 20% output voltage drop.
Start-up Time:
Start up delay 1 second. (varies with AC supply voltage)
Walk-in delay 6 seconds at full output. (varies with DC output voltage)
48 800 16.6
V
nominal output voltage.
W
nominal output power.
A
maximum output current.
Protection:
Current Limit:
Adjustable to 50-100% of maximum rated current.
Over Temperature:
Automatic current turndown, backup shutdown protection.
Polarity Reversal:
Output fuse with crowbar diode.
Over voltage:
Adjustable limit.
Noise: (under nominal conditions)
Ripple <100Hz:
<1mV rms unweighted
Voice band 100Hz-5KHz:
<2mV rms psophometric
Wide band 5kHz-1MHz:
<5mV rms unweighted
Peak to Peak 0-20MHz:
<50mV peak to peak
Isolation:
Input to Output:
4000V DC
Input to Chassis:
3500V DC (VDR to chassis removed)
Output to Chassis:
2100V DC
Environmental Requirements Ambient Temperature:
Nominal:
25+/-5ºC
Range:
-20ºC to +70ºC (maximum output power is derated above +50ºC)
Storage Temperature:
-20ºC to +70ºC
Humidity:
0-98% RH (non-condensing)
Altitude:
<3000m, De-rate maximum ambient temperature
by 4ºC per 1000m above sea level.
Mechanical Dimensions, W, H, D:
55mm , 44mm (1U), 235mm overall (rack depth 260mm)
Weight:
800g
Shipping Dimensions W, H, D:
100mm, 80mm, 300mm
Shipping Weight:
1.0kg
Cooling:
Forced cooled.
Compliances Safety:
EN60950
Electrostatic Discharge:
CISPR24
Radiated Radio Frequency:
CISPR22
AC Harmonics:
EN61000-3-2
AC Flicker and Fluctuation:
EN61000-3-3
Other:
CE & RoHS compliant. ENATEL | 2010 PRODUCT CATALOGUE | 33
FLAT MOUNT RECTIFIERS - Forced cooled.
Flat mount rectifiers have been developed to allow provision of simple, and low
- Thermally protected.
cost solutions where only a limited amount of rack space is available. With all
- Power factor corrected.
input and output connections available on the front panel of the rectifier units
- Input/output voltage
they can be easily integrated in simple DC systems solutions.
and current protected.
- Temperature compensation. - Automatic float/boost charge cycle. - Alarm and control interface
including active load sharing.
- Optional built-in low
voltage disconnect.
With power ratings of 300W up to 1.4kW and output voltages of 12, 24 and 48V DC these rectifiers offer temperature compensation, and auto float/boost switching as standard. They have options available for internal low voltage disconnect (LVD) and an
- Optional internal alarm
alarm card, with relay outputs. These rectifiers can provide the powering solution
for most small and medium telecommunications, and data networking power
card with relay outputs.
applications. Efficient and reliable, these rack mounting rectifiers allow for easy paralleling of modules to provide redundancy or higher power outputs. Internal options include low voltage disconnect (LVD) and an alarm card with relay outputs. The unique design allows for mounting two rectifiers in a 1U x 19â&#x20AC;? rack space. Custom configurations can be specified and additional features can be added. Easy to install and compact, these robust, reliable rectifiers are forced cooled by a speed controlled and monitored fan.
34 | ENATEL | 2010 PRODUCT CATALOGUE
RF SERIES FLAT MOUNT RECTIFIERS AC Input Nominal: Voltage Range: Frequency Range: Power Factor: Efficiency: Maximum Input Current: Input Fuses: Protection: Input Voltage: Input Rush: DC Output Nominal Voltage: Rated Voltage: Voltage Range: Maximum Current: Regulation: Line: Load: Hold-up Time: Start-up Time: Protection: Current Limit: Over Temp: Polarity Reversal: Over Voltage: Noise: (under nominal conditions) Ripple <100Hz: Voice Band 100Hz to 5KHz: Wide Band 5kHz to 1 MHz: Peak to Peak 0 to 20MHz: Isolation: Input to Output: Input to Chassis: Output to Chassis: Environmental Requirements Nominal Ambient Temperature: Range: Humidity: Altitude:
RF1448 RF1124 220/240V, 50/60Hz 220/240V, 50/60Hz 180-275V AC 180-275V AC (full power output), (full power output), 150-180V AC 150-180V AC (reduced power output) (reduced power output) 45-66Hz >0.93 (full load) RF1448 RF1124 90% 92% 8.5A 8.5A HRC fuses in phase & neutral.
RF748U 110-220V, 50/60Hz 100-275V AC (full power output), 85-100V AC (reduced power output)
RF624U 110-220V, 50/60Hz 100-275V AC (full power output), 85-100V AC (reduced power output)
RF512U 110-220V, 50/60Hz 100-275V AC (full power output), 85-100V AC (reduced power output)
RF348U 110-220V, 50/60Hz 100-275V AC (full power output), 85-100V AC (reduced power output)
RF748U 89% 8.5A
RF624U 87% 8.5A
RF512U 85% 8.5A
RF348U 85% 8.5A
RF624U 24V 29V 22-30V 22A
RF512U 12V 14.5V 11.5-15V 40A
RF348U 48V 58V 45-60V 6A
RF624U <5mV rms unweighted. <1mV rms psophometric. <5mV rms unweighted. <50mV p-p unweighted.
RF512U RF348U <5mV rms unweighted. <5mV rms unweighted. <0.5mV rms psophometric. <0.5mV rms psophometric. <2.5mV rms unweighted. <2.5mV rms unweighted. <50mV p-p unweighted. <50mV p-p unweighted.
Automatic shutdown, restarts automatically when correct voltage restored. <2x maximum input current. RF1448 48V 58V 45-60V 25A
RF1124 24V 29V 22-30V 40A
RF748U 48V 58V 45-60V 12A
±0.1% ±0.5% (no load to full load) >15ms for 20% output voltage drop. Walk-in delay 2 seconds. (depends on AC input voltage) Adjustable to 50-100% of maximum rated current. Automatic current turndown, backup shutdown protection. Output fuse with crowbar diode. Adjustable limit. RF1124 RF748U RF1448 <10mV rms unweighted. <5mV rms unweighted. <10mV rms unweighted. <2mV rms psophometric. <1mV rms psophometric. <2mV rms psophometric. <10mV rms unweighted. <5mV rms unweighted. <10mV rms unweighted. <50mV p-p unweighted. <50mV p-p unweighted. <50mV p-p unweighted. 3000V AC 2500V AC (VDR to chassis removed) 1500V AC 25+/-5°C -10 to +50°C 5-95% RH (non-condensing.) <2500m de-rate maximum ambient temperature by +4˚ per 1000m above sea level.
Mechanical Dimensions, W, H, D: Weight: Shipping Dimensions, W, H, D: Shipping Weight: Cooling: Connections: Mains: Output to Load: Temperature Sensor: Monitor Connection: Internal Alarm Card:
IEC 320 universal connection. 4 way lumberg macromodule. 2 way lumberg macromodule. RJ45 Mini combicon.
Standard Features Temperature Compensation: Auto Float/Boost: Alarm and Indicator Controls:
Output voltage slope adjustable 0.1 to 0.2%/°C (standard) Rectifier enters boost mode at power up. When battery current reduces to float threshold limit (adjustable from 0.1A to 40% MRC), unit reverts to float voltage setting. When in boost but out of current limit, rectifier will automatically switch back to float after approximately four hours. If battery current exceeds the float threshold limit when the rectifier is in float mode it will automatically switch to boost mode. Positive V out, Load share signal (in/out), External shutdown, Open collector ‘off normal’ alarm, (OSVD, over temp., current limit, fan fail), LVD synchronisation signal (in/out), Temperature compensation input signal, Open collector rectifier fail (via 4k7 resistor), Open collector mains fail, Negative V out.
Options Low Voltage Disconnect: Voltage Adjustment Range: Maximum Load Current: Internal Alarm Card:
RF1448 RF1124 RF748U RF624U RF512U RF348U 38-48V 19-24V 38-48V 19-24V 9.5-12V 38-48V 25A 40A 12A 22A 40A 6A 4x N.O or N.C (selectable) relay contacts with single common for rectifier fail, off normal, float low, float high. 1x VF changeover relay contact for mains fail. Relay contacts rated at 100V DC 1A. Connections via “mini combicon” connector accepts 1.5mm dia wire.
Maintenance LED Indicators: Internal Adjustments:
Green - Mains on. (primary converter operating) Green - Temperature probe connected and within normal limits. Red - Rectifier ‘failed’. Green - Rectifier in ‘float’ mode. Yellow - Rectifier in ‘boost’ mode. Yellow - Rectifier in ‘current’ limit. Red - Rectifier ‘off normal’. (over temp., OVSD, low output volts) Float voltage. Boost voltage. Over voltage shut down. Current limit. Temperature compensation slope. Auto boost to float threshold limit. Load disconnect voltage. (if fitted) Load disconnect hysteresis voltage. (if fitted)
Compliances Safety: Electrostatic Discharge: Radiated Radio Frequency: AC Harmonics: AC Flicker and Fluctuation:
EN60950 CISPR24 CISPR22 EN61000-3-2 EN61000-3-3
Ordering Information RFxxxx-10: RFxxxx-11: RFxxxx-20: RFxxxx-21:
Standard Standard Standard Standard
227mm, 44mm (1U), 270mm, (293mm over handle) 1.5kg 377mm, 235mm, 122mm 2.4kg Forced cooled.
with with with with
temperature temperature temperature temperature
compensation, compensation, compensation, compensation,
auto auto auto auto
float float float float
boost, boost, boost, boost,
alarm alarm alarm alarm
and and and and
control control control control
I/F. I/F, low volts disconnect. I/F, alarm card. I/F, low volts disconnect, alarm card.
ENATEL | 2010 PRODUCT CATALOGUE | 35
WALL MOUNT RECTIFIERS - Convection cooled.
The Enatel RW series of wall mount rectifiers have been developed to provide
- Thermally protected.
fully integrated power solutions for small telecommunications, and data
- Power factor corrected.
networking applications.
- Input/output voltage
and current protected.
- Automatic float/boost
charge cycle.
- Alarm and control interface
with active load sharing.
- Temperature compensation. - Output current indicator.
Easily paralleled to provide redundancy, or higher power outputs these rectifiers are simple to install and can be bolted directly to a wall or flat panel space. Providing outputs of 12, 24 and 48V from 300W up to 700W output these rectifiers offer temperature compensation, and auto float/boost switching as standard.
- Optional built-in low
They have options available for internal low voltage disconnect (LVD) and an
alarm card, with relay outputs. These highly efficient rectifiers offer a range of
voltage disconnect.
- Optional internal alarm
output voltages and power levels.
card with relay outputs. Easy to install and compact, these robust, reliable rectifiers are convection cooled and are available with temperature compensation, and options for internal low voltage disconnect (LVD) and alarm card with relay outputs. They can be used as standalone power sources or can be operated in parallel to provide redundancy or higher output ratings. Choose from a range of internal options including load disconnect, current indicators, alarm and control interface and auto float/boost. Custom configurations can be specified and additional features can be added.
36 | ENATEL | 2010 PRODUCT CATALOGUE
RW SERIES WALL MOUNT RECTIFIERS AC Input Nominal: Voltage Range: Frequency Range: Power Factor: Efficiency: Maximum Input Current: Input Fuses: Protection: Input Voltage: Input Rush: DC Output Nominal Voltage: Rated Voltage: Voltage Range: Maximum Current: Regulation: Line: Load: Hold-up Time: Start-up Time: Protection: Current Limit: Over Temp: Polarity Reversal: Over Voltage: Noise: (under nominal conditions) Ripple <100Hz: Voice Band 100Hz to 5KHz: Wide Band 5kHz to 1 MHz: Peak to Peak 0 to 20MHz: Isolation: Input to Output: Input to Chassis: Output to Chassis: Environmental Requirements Nominal Ambient Temperature: Range: Humidity: Altitude:
110/220V, 50/60Hz 100-275V AC (full power output), 85-100V AC (reduced power output) 45-66Hz >0.99 (full load) RW748U RW624U RW512U 88% 87% 85% 8.5A 8.5A 8.5A HRC fuses in phase & neutral.
RW348U 88% 8.5A
RW324U 87% 4A
RW312U 85% 4A
RW348U 48V 58V 45-60V 6A 300W
RW324U 24V 29V 22-30V 10A 300W
RW312U 12V 14.5V 11.5-15V 20A 300W
RW324U <5mV rms unweighted. <1mV rms psophometric. <5mV rms unweighted. <50mV p-p unweighted.
RW312U <5mV rms unweighted. <0.5mV rms psophometric. <2.5mV rms unweighted. <50mV p-p unweighted.
Automatic shutdown, restarts automatically when correct voltage restored. <2x maximum input current. RW748U 48V 58V 45-60V 12A 700W
RW624U 24V 29V 22-30V 22A 600W
RW512U 12V 14.5V 11.5-15V 35A
±0.1% ±0.5% (no load to full load) >15ms for 20% output voltage drop. Walk-in delay 2 seconds (depends on AC input voltage) Adjustable to 50-100% of maximum rated current. Automatic current turndown, backup shutdown protection. Output fuse with crowbar diode. Adjustable limit. RW748U RW624U RW512U RW348U <10mV rms unweighted. <5mV rms unweighted. <5mV rms unweighted. <10mV rms unweighted. <2mV rms psophometric. <1mV rms psophometric. <0.5mV rms psophometric. <2mV rms psophometric. <10mV rms unweighted. <5mV rms unweighted. <2.5mV rms unweighted. <10mV rms unweighted. <50mV p-p unweighted. <50mV p-p unweighted. <50mV p-p unweighted. <50mV p-p unweighted. 3000V AC. 2500V AC (VDR to chassis removed) 1500V AC 25+/-5°C -10 to +50°C 5-95% RH (non-condensing) <2500m de-rate maximum ambient temperature by +4˚ per 1000m above sea level.
Mechanical Dimensions, W, H, D: Weight: Shipping Dimensions, W, H, D: Shipping Weight: Cooling: Connections: Mains: Output to Load: Output to Batteries: Temperature Sensor: Monitor Connection: Internal Alarm Card:
IEC 320 universal connection. 4 way lumberg macromodule. 4 way lumberg macromodule. 2 way lumberg macromodule. RJ45. Mini combicon.
Standard Features Output Current Indicator: Temperature Compensation: Auto Float/Boost: Alarm and Indicator Controls:
Ten segment red LED “dot” display (standard) Output voltage slope adjustable 0.1 to 0.2%/°C (standard) Rectifier enters boost mode at power up. When battery current reduces to float threshold limit (adjustable from 0.1A to 40% MRC), unit reverts to float voltage setting. When in boost but out of current limit, rectifier will automatically switch back to float after approximately four hours. If battery current exceeds the float threshold limit when the rectifier is in float mode it will automatically switch to boost mode. Positive V out, Load share signal (in/out), External shutdown, Open collector ‘off normal’ alarm (OSVD, over temp. limit), LVD synchronisation signal (in/out) Temperature compensation input signal, Open collector rectifier fail (via 4k7 resistor), Open collector mains fail, Negative V out.
Options Low Voltage Disconnect: Voltage Adjustment Range: Maximum Load Current: Internal Alarm Card:
RW748U RW624U RW512U RW348U RW324U RW312U 38-48V 19-24V 9.5-12V 38-48V 19-24V 9.5-12V 12A 22A 35A 6A 10A 20A 4x N.O or N.C (selectable) relay contacts with single common for rectifier fail, off normal, float low, float high. 1x VF changeover relay contact for mains fail. Relay contacts rated at 100V DC 1A. Connections via “mini combicon” connector accepts 1.5mm dia wire.
Maintenance LED Indicators: Internal Adjustments:
Green - Mains on. (primary converter operating) Green - Temperature probe connected and within normal limits. Red - Rectifier ‘failed’. Green - Rectifier in ‘float’ mode. Yellow - Rectifier in ‘boost’ mode. Yellow - Rectifier in ‘current’ limit. Red - Rectifier ‘off normal’. (over temp. OVSD, low output volts) Float voltage. Boost voltage. Over voltage shut down. Current limit. Temperature compensation slope. Auto boost to float threshold limit. Load disconnect voltage. (if fitted) Load disconnect hysteresis voltage. (if fitted)
Compliances Safety: Electrostatic Discharge: Radiated Radio Frequency: AC Harmonics: AC Flicker and Fluctuation:
EN60950 CISPR24 CISPR22 EN61000-3-2 EN61000-3-3
Ordering Information RWxxxx-10: RWxxxx-11: RWxxxx-20: RWxxxx-21:
Standard Standard Standard Standard
311mm, 163mm, 62mm 1.5kg 377mm, 235mm, 122mm 2.4kg Convection cooled.
with with with with
temperature temperature temperature temperature
compensation, compensation, compensation, compensation,
auto auto auto auto
float float float float
boost, boost, boost, boost,
alarm alarm alarm alarm
and and and and
control control control control
I/F. I/F, low volts disconnect. I/F, alarm card. I/F, low volts disconnect, alarm card.
ENATEL | 2010 PRODUCT CATALOGUE | 37
DC-AC POWER SYSTEMS - Integrated monitoring presents
Enatelâ&#x20AC;&#x2122;s ISM series inverter solutions offer a hot swappable modular inverter
system for supplying critical AC loads in telecom, and data networking
simplified systems management.
- Hot-swap/hot-plug modules
applications.
with n+1 redundancy.
- Small size means more room for
revenue generating equipment.
- Fully featured telecom
single point.
monitoring optional.
The inverter modules are available in 1.5kVA with either 110/120 or 220/230V AC
- High reliability means
output, and are scalable up to 15kVA. The inverter system solutions also include
less cost of maintenance.
- Full remote monitoring reduces
12kVA static switch and maintenance bypass modules.
maintenance costs.
- Easily customized and configured to
integrate AC/DC rectifiers, DC/DC converters and also DC/AC inverters into a system with a single controller, providing remote monitoring capabilities from a
grade inverters.
- TCP/IP and SNMP network
One of the unique features offered by the Enatel system solution is the ability to
For further information on Enatelâ&#x20AC;&#x2122;s range of inverter systems, contact us today.
suit eachcustomers individual needs.
7U Inverter System
Supervisory Module
SM32
IM10230-48
38 | ENATEL | 2010 PRODUCT CATALOGUE
IM10230-48
IM10230-48
IM10230-48
IM10230-48
IM10230-48
IM10230-48
IM10230-48
IM10230-48
DC-AC INVERTERS Efficient and reliable, these modular rack mount inverters allow for easy
- Pure sine wave.
paralleling of modules to provide redundancy or higher power outputs.
- Hot swapable.
Designed for use in modern telecommunications networks these inverters
- High efficiency.
offer unrivalled power densities.
- Smart fan speed control. - Wide operation temperature range.
The unique design allows for mounting nine inverters in a 5U x 19” rack space or two inverters in a 1U x 19” rack space. “Plug and Play” installation allows quick and easy installation and system expansion. These robust, reliable inverters are forced cooled by two speed controlled and monitored high reliability fans.
- DSP chip designed. - N+X redundancy system. - Lower audible noise. - High power density. - Enatel RCP bus. - 48V DC telecom system application. - CE & RoHS compliant.
ENATEL | 2010 PRODUCT CATALOGUE | 39
IM SERIES MODULAR INVERTERS DC Input Operating Voltage Range:
40.5-58V DC
AC Output Nominal Output Voltage:
110/230V AC (refer to part number table below for model numbers)
Output Voltage Range:
110/115/120V AC or 208/220/230/240V AC
Output Voltage Tolerance:
+/- 2%
Output Voltage Frequency:
50/60Hz selectable.
Output Frequency Tolerance:
+/- 0.5%
Total Harmonic Distortion:
<3% on linear loads.
<5% for non linear loads.
Turn On Delay:
<3 seconds.
Crest Factor:
3:1 (nominal power)
Efficiency:
90%
Output Power
(refer to part number table below for model numbers)
Nominal Value:
1000VA, 800W/
1500VA, 1200W
Overload (5 Seconds):
2000VA
Permanent Overload:
10%
Admissible Load Power Factor:
0 inductive to 0 capacitive (100% load)
Isolation:
Input/Output:
2500V AC
Output/Earth:
2500V AC
Input Earth:
1500V AC
Operating Temperature Range:
-40ยบC to +50ยบC, derated to +70ยบC
Acoustic Noise:
<55dBa @ 1m
Display:
3x LEDs, fail, off normal, power on.
Serial Comms:
Enatel SBI interface to SM3X supervisory module.
Mechanical Dimensions, W, H, D:
215mm, 43.8mm, 270mm overall.
Weight:
2.5kg
Shipping Dimensions W, H, D:
52mm, 230mm, 340mm
Shipping Weight:
2.65kg
Cooling:
Forced cooled.
Compliances Immunity:
CISPR24
Emissions:
CISPR22 Class B
Safety:
IEC60950
Other:
CE & RoHS compliant.
Part Numbers
40 | ENATEL | 2010 PRODUCT CATALOGUE
IM10230-48:
1U, 48V DC input, 230V AC output, 1.0kVA 800W
IM10110-48:
1U, 48V DC input, 120V AC output, 1.0kVA 800W
IM15230-48:
1U, 48V DC input, 230V AC output, 1.5kVA 1200W
IM15110-48:
1U, 48V DC input, 120V AC output, 1.5kVA 1200W
SBM SERIES STATIC BYPASS MODULE The Enatel SBM series static bypass module increases system reliability by
- Universal input range.
automatically switching between the inverter output and the utility supply.
- Hot-swap replacement in shelf. - Back feed protection.
The SBM12000 can be programmed so that the system operates in a standby
- Redundant fan design.
backup mode were the utility is the normal source of supply or alternatively the
- Redundant power supply design.
system can be the normal source of supply with automatic switchover to the utility in the event of system failure.
- Fast transfer time, typically
less than ¼ cycle.
- Wide operation temperature
range -20 to +70°C.
- Lower audible noise <55dBA.
Input
- Emergency power off
AC Voltage Range:
function embedded.
110/115/120V AC:
From 89 to 138V AC.
- No-cross connect.
208/220/240V AC:
176 to 276V AC.
- Optional maintenance bypass
Over Voltage Threshold:
switch function with interlock.
- Operation priority setup of
Adjustable Using Controller: 220 to 240V AC for 208V AC systems.
transfer side by setting in
233 to 252V AC for 220V AC systems.
controller module.
244 to 264V AC for 230V AC systems.
254 to 276V AC for 240V AC systems.
117 to127V AC for 110V AC systems.
122 to 132V AC for 115V AC systems.
127 to 138V AC for 120V AC systems.
Under Voltage Threshold:
Adjustable Using Controller:
176 to 198V AC for 208V AC systems.
176 to 209V AC for 220V AC systems.
185 to 218V AC for 230V AC systems.
193 to 228V AC for 240V AC systems.
89 to 105V AC for 110V AC systems.
93 to 110V AC for 115V AC systems.
100 to 114V AC for 120V AC systems.
Redundant Power Supply Design:
Startup power-on by priority source or alternative.
Output Waveform:
Sinusoidal.
Nominal Output Voltage:
Same as mains AC or the output of inverter modules.
Permissible Frequency Area:
Max. ±2.5% (Synchronize area of inverter).
±1.5Hz for 60Hz inverter.
±1.25Hz for 50Hz inverter.
Transfer Time:
Typical ¼ cycle.
Rated Current:
50A (All voltage settings).
Operation Methods:
Inverter priority or utility priority (Programmable).
Part Number: SBM12000:
50A/12kVA static bypass module. ENATEL | 2010 PRODUCT CATALOGUE | 41
DC-DC CONVERTERS - Force cooled.
These converters offer plug and play operation, and can be easily paralleled to
- Thermally protected.
provide higher power outputs.
- Input/output voltage
and current protected.
- Wide input voltage range. - Serial alarm and control interface. - Microprocessor controlled.
These units offer the same high levels of conversion efficiency as other Enatel power products, and will provide the same benefits to the customer of reduced operating costs and lower levels of heat dissipation. The converters include a relay contact to indicate converter failure, and have a load share input that ensures that all units connected in parallel carry an equal share of the load.
42 | ENATEL | 2010 PRODUCT CATALOGUE
CM SERIES 1.7kW MODULAR DC-DC CONVERTERS DC Input
CM1760-48
CM1748-60
CM1748-48
Nominal Input Voltage:
48V
60V
48V
Input Voltage Range:
40-60V
52-74V
40-60V
Input Protection:
Fuses:
Fuse in the positive input with crowbar diode.
Input Voltage:
Converter shuts down when input voltage is out of range,
Automatically restarts when correct voltage is restored.
DC Output
CM1760-48
CM1748-60
CM1748-48
Nominal Output Voltage:
60V
48V
48V
Output Voltage Range:
57-65V
46-52V
46-52V
Maximum Output Current:
27A
33A
33A
Maximum Output Power:
1700W
1700W
1700W
Efficiency:
91%
91%
91%
Regulation:
Line:
± 0.1%
Load:
± 0.5% (no load to full load)
Start-up Time:
Walk-in delay 2-8 seconds depending on load.
Protection:
Current Limit:
Adjustable to 50-100% of maximum rated current.
Over Temperature:
Auto current turndown, backup shutdown protection.
Polarity Reversal:
Output fuse in positive with crowbar diode.
Over Voltage:
Adjustable limit.
Noise: (under nominal conditions)
Ripple <100Hz:
<1mV rms unweighted
Voice Band 100Hz-5KHz:
<1mV rms psophometric
Wide Band 5kHz-1MHz:
<5mV rms unweighted
Peak to Peak 0-20MHz:
<50mV peak to peak
Isolation:
Input to Output:
4230V DC
Input to Chassis:
2115V DC (VDR to chassis removed)
Output to Chassis:
2115V DC
Environmental Requirements Ambient Temperature:
Nominal:
+25 +/- 5ºC
Range:
-10 to +70ºC (maximum output power is derated above +50ºC)
Storage Temperature:
-20 to +70ºC
Humidity:
5-95% RH (non condensing)
Altitude:
<2500m, De-rate maximum ambient temperature
by +4ºC per 1000m above sea level.
Mechanical Dimensions W, H, D:
111.5mm, 44mm (1U), 282 overall (rack depth 260mm)
Weight:
1.1kg
Shipping Dimensions W, H, D:
170mm, 52mm, 325mm
Shipping Weight:
1.6kg
Cooling:
Forced cooled.
Compliances Safety:
EN60950
Electostatic Discharge:
CISPR24
Radiated Radio Frequency:
CISPR22
Additional Accesories ACM-4T:
1U 4 position DC-DC converter shelf, no cables.
Part Numbers CM1760-48:
1.7kW 48 to 60V DC modular DC-DC converter.
CM1748-60:
1.7kW 60 to 48V DC modular DC-DC converter.
CM1748-48:
1.7kW 48 to 48V DC modular DC-DC converter. ENATEL | 2010 PRODUCT CATALOGUE | 43
CM SERIES 500W to 1.0kW MODULAR DC-DC CONVERTERS DC Input Nominal Input Voltage: Input Voltage Range: Input Protection: Fuses: Input Voltage:
CM1048-24 CM1024-48 CM648-24 24V 48V 24V 20-30V 40-60V 20-30V
CM624-48 48V 40-60V
Fuse in the positive input with crowbar diode. Converter shuts down when input voltage is out of range, Automatically restarts when correct voltage is restored.
DC Output CM1048-24 CM1024-48 CM648-24 CM624-48 Nominal Output Voltage: 48V 24V 48V 24V Output Voltage Range: 46-52V 22-26V 46-52V 22-26V Maximum Output Current: 21.6A 43A 13.5A 25A Maximum Output Power: 1040W 1040W 650W 650W 91% 91% Efficiency: 91% 91% Regulation: ± 0.1% Line: Load: ± 0.5% (no load to full load) Start-up Time: Walk-in delay 2-8 seconds depending on load and output Protection: Adjustable to 50-100% of maximum rated current. Current Limit: Over Temperature: Auto current turndown, backup shutdown protection. Polarity Reversal: Output fuse in positive with crowbar diode. Over Voltage: Adjustable limit. Noise: (under nominal conditions) Ripple <100Hz: <1mV rms unweighted Voice Band 100Hz-5KHz: <1mV rms psophometric Wide Band 5kHz-1MHz: <5mV rms unweighted Peak to Peak 0-20MHz: <50mV peak to peak Isolation: 4230V DC Input to Output: 2115V DC (VDR to chassis removed) Input to Chassis: Output to Chassis: 2115V DC Environmental Requirements Ambient Temperature: Nominal: Range: Storage Temperature: Humidity: Altitude:
CM612-48 12V 11-14V 40A 560W 89%
voltage.
+25 +/- 5ºC -10 to +70ºC (maximum output power is derated above +50ºC) -20 to +70ºC 5-95% RH (non condensing) <2500m, De-rate maximum ambient temperature by +4ºC per 1000m above sea level.
Mechanical Dimensions W, H, D: 111.5mm, 44mm (1U), 282 overall (rack depth 260mm) Weight: 1.1kg Shipping Dimensions W, H, D: 170mm, 52mm, 325mm Shipping Weight: 1.6kg Cooling: Forced cooled.
44 | ENATEL | 2010 PRODUCT CATALOGUE
CM612-48 48V 40-60
Compliances Safety: Electostatic Discharge: Radiated Radio Frequency: Other:
EN60950 CISPR24 CISPR22 CE & RoHS compliant
Additional Accesories ACM-4T:
1U 4 position DC-DC converter shelf, no cables.
Part Numbers CM1048-24: CM1024-48: CM648-24: CM624-48: CM612-48:
1.0kW 24 to 48V DC modular DC-DC converter. 1.0kW 48 to 24V DC modular DC-DC converter. 650W 24 to 48V DC modular DC-DC converter. 650W 48 to 24V DC modular DC-DC converter. 560W 48 to 12V DC modular DC-DC converter.
MONITORING Enatel offer a range of supervisory modules and monitoring options, which have
- Temperature compensation.
been designed to work with our power products. Allowing for easy integration
- LVD control.
into our complete DC power systems solutions for telecommunications and data
- Setup from front panel.
networking applications.
- Boost control and timer. - LCD display of parameters.
ENATEL | 2010 PRODUCT CATALOGUE | 45
SM36 SUPERVISORY MODULE
LVD WEB USB dual lvd control.
web based configurator.
usb port for local connection.
46 | ENATEL | 2010 PRODUCT CATALOGUE
Input Voltage: Current: Interface Display: Communications: Serial: Relay: TCP/IP: LVD: Indicators: 3x LED’s: Audible: Controls: Signal Inputs: Alarms: Alarm Contacts: Default Alarm Map: Relay 1: Relay 2: Relay 3: Relay 4 - 6: Logging Capacity: Periodic Log: Event Log: Battery Mid-point Monitoring:
16-75V DC <150mA maximum.
4 line x 16 character multi-lingual alpha numeric display. 1x USB port on front panel for local PC interface. 1x RS232 port, rear mounted for remote serial/modem communications. 6x alarm and control relays, five of which can be mapped for customized alarm settings. (extra available with I/O expansion board) Ethernet interface for communication using SNMP protocol and internal web based configurator. 3x standard or 2x pulse control LVD contacts. (for magnetically latched LVD contactors) Green - power on/monitor OK. Yellow - non urgent alarm. Red - urgent alarm. 90dBA buzzer mappable to user defined conditions. 3x push buttons for parameter setting or viewing on front panel. 2x serial buses for rectifier control and interface to peripheral modules. 10x general purpose inputs. (6x for customer connection, 4x reserved for internal system connection.) 4x battery MCB sensors. (reserved for internal system connection.) 3x current shunt inputs. (reserved for internal system connection.) 1x DC voltage inputs. (reserved for internal system connection.) 6x alarm relays. 0.3A 100V volts free changeover contacts. Monitor fail. (non programmable.) Non-urgent. (programmable.) Urgent. (programmable.) Unassigned. Typically 16000 records. (dependant on number of parameters logged.) Typically 16000 records. (dependant on number of parameters logged.) 3x strings with individual string currents. (more available with shared string currents.)
Physical Dimensions, W, H, D: Weight: Connections: Operating Temperature: Storage Temperature:
111.5mm , 44mm (1U), 265mm overall (rack depth 244mm) 365g Relay outputs, mini combicon to accept 1.5mm csa wire. Serial communications to rectifier shelf & peripheral devices - RJ45. USB port - USB mini B. -25 to +55°C -50 to +85°C
Compliances Radiated Emissions: RF Susceptibility:
EN55022 EN55024
Optional Accessories ACA-TC3C: ACA-TC7C: ASM-AC3P: ASM-ABM-24: ASM-SM36IO: Voltage Range: Current: Connection: Alarms: Signal Inputs: Operating Temperature: Storage Temperature:
3m temperature sensor and cable. 7m temperature sensor and cable. 3 phase AC voltage and current monitor. Battery condition monitor, 24 blocks. (maximum 4x BCM cards) Standard I/O expansion board (maximum of 4 per supervisory module.) 15-75V DC <150mA maximum Connects via rectifier serial bus, 2x RJ45. Up to 8x alarm and control relays, able to be mapped for customized alarm settings. Up to 6x digital inputs. Up to 6x analogue inputs. -25 to +55°C -50 to +85°C
Part Numbers SM36-00: SM36-00-1U: SM36-10-1U: SM36-00-PM: SM36-10-PM:
Standard 1U modular controller, 6x relays, 6x digital inputs. Standard 1U x 19” mounting version controller, 6x relays, 6x digital inputs. Standard 1U x 19” mounting version controller, 6x relays, 6x digital inputs; with standard I/O expansion board. Standard panel mount version controller, 6x relays, 6x digital inputs. Standard panel mount version controller, 6x relays, 6x digital inputs; with standard I/O expansion board.
SM35 SUPERVISORY MODULE Input Voltage: Current: Interface Display: Communications: Serial: Relay: LVD: Indicators: 3x LED’s Audible: Controls: Signal Inputs: Alarms: Alarm Contacts: Default Alarm Map: Relay 1: Relay 2: Relay 3: Relay 4 - 6: Logging Capacity: Periodic Log: Event Log: Battery Mid-point Monitoring:
16-75V DC <150mA maximum.
4 line x 16 character multi-lingual alpha numeric display. 1x USB port on front panel for local PC interface. 6x alarm and control relays, five of which can be mapped for customized alarm settings. 3x standard or 2x pulse control LVD contacts. (for magnetically latched LVD contactors) Green - power on/monitor OK. Yellow - non urgent alarm. Red - urgent alarm. 90dBA buzzer mappable to user defined conditions. 3x push buttons for parameter setting or viewing on front panel. 2x serial buses for rectifier control and interface to peripheral modules. 10x general purpose inputs. (6x for customer connection, 4x reserved for internal system connection.) 4x battery MCB sensors. (reserved for internal system connection.) 3x current shunt inputs. (reserved for internal system connection.) 1x DC voltage inputs. (reserved for internal system connection.) 6x alarm relays. 0.3A 100V volts free changeover contacts.
126 LCD USB
serial control for up to 126 rectifiers/ converters plus peripheral devices.
lcd display.
usb port for local connection.
Monitor fail. (non programmable.) Non-urgent. (programmable.) Urgent. (programmable.) Unassigned. Typically 16000 records. (dependant on number of parameters logged.) Typically 16000 records. (dependant on number of parameters logged.) 3x strings with individual string currents. (more available with shared string currents.)
Physical Dimensions, W, H, D: Weight: Connections: Operating Temperature: Storage Temperature:
111.5mm , 44mm (1U), 265mm overall (rack depth 244mm) 325g Relay outputs, mini combicon to accept 1.5mm csa wire. Serial communications to rectifier shelf & peripheral devices - RJ45. USB port - USB mini B. -25 to +55°C -50 to +85°C
Compliances Radiated Emissions: RF Susceptibility:
EN55022 EN55024
Optional Accessories ACA-TC3C: ACA-TC7C: ASM-AC3P: ASM-ABM-24: ASM-SM3XIO: Voltage Range: Current: Connection: Alarms: Signal Inputs: Operating Temperature: Storage Temperature:
3m temperature sensor and cable. 7m temperature sensor and cable. 3 phase AC voltage and current monitor. Battery condition monitor, 24 blocks. (maximum 4x BCM cards.) Standard I/O expansion board (maximum of 4 per supervisory module.) 15-75V DC <150mA maximum Connects via rectifier serial bus, 2x RJ45. Up to 8x alarm and control relays, able to be mapped for customized alarm settings. Up to 6x digital inputs. Up to 6x analogue inputs. -25 to +55°C -50 to +85°C
Part Numbers SM35-00: SM35-00-1U: SM35-10-1U: SM35-00-PM: SM35-10-PM:
Standard 1U modular controller, 6x relays, 6x digital inputs. Standard 1U x 19” mounting version controller, 6x relays, 6x digital inputs. Standard 1U x 19” mounting version controller, 6x relays, 6x digital inputs; with standard I/O expansion board. Standard panel mount version controller, 6x relays, 6x digital inputs. Standard panel mount version controller, 6x relays, 6x digital inputs; with standard I/O expansion board. ENATEL | 2010 PRODUCT CATALOGUE | 47
SM32 SUPERVISORY MODULE
LVD WEB USB dual lvd control.
web based configurator.
usb port for local connection.
48 | ENATEL | 2010 PRODUCT CATALOGUE
Input Voltage: Current: Interface Display: Communications: Serial: Relay: TCP/IP: LVD: Indicators: 3x LED’s Audible: Controls: Signal Inputs: Alarms: Alarm Contacts: Default Alarm Map: Logging Capacity: Periodic Log: Event Log:
16-75V DC <150mA maximum.
4 line x 16 character multi-lingual alpha numeric display. 1x USB port on front panel for local PC interface. 1x RS232 port, rear mounted for remote serial/modem communications. 3x alarm and control relays, two of which can be mapped for customized alarm settings. (extra available with I/O expansion board) Ethernet interface for communication using SNMP protocol and internal web based configurator. 3x standard or 2x pulse control LVD contacts. (for magnetically latched LVD contactors) Green - power on/monitor OK. Yellow - non urgent alarm. Red - urgent alarm. 90dBA buzzer mappable to user defined conditions. 3x push buttons for parameter setting or viewing on front panel. Serial bus for rectifier control and interface to peripheral modules. Fuse fail. 5x spare digital inputs. 2x temperature sensors. 3x current shunts. 2x DC voltage inputs. 3x alarm relays. 0.3A 100V volts free changeover contacts. Urgent. Non-urgent. Monitor fail. 16384 records. (dependant on number of parameters logged.) 16384 records. (dependant on number of parameters logged.)
Physical Dimensions, W, H, D: Weight: Connections: Operating Temperature: Storage Temperature:
111.5mm , 44mm (1U), 282mm overall (rack depth 260mm) 1.5kg Relay outputs, mini combicon to accept 1.5mm csa wire. Serial communications to rectifier shelf & peripheral devices - RJ45. USB port - USB mini B. -25 to +55°C -50 to +85°C
Compliances Radiated Emissions: RF Susceptibility:
EN55022 EN55024
Optional Accessories ACA-TC3C: ACA-TC7C: ASM-AC3P: ASM-ABM-24: ASM-SM3XIO: Voltage Range: Current: Connection: Alarms: Signal Inputs: Operating Temperature: Storage Temperature:
3m temperature sensor and cable. 7m temperature sensor and cable. 3 phase AC voltage and current monitor. Battery condition monitor, 24 blocks. (maximum 4x BCM cards.) Standard I/O expansion board (maximum of 4 per supervisory module.) 15-75V DC <150mA maximum Connects via rectifier serial bus, 2x RJ45. Up to 8x alarm and control relays, able to be mapped for customized alarm settings. Up to 6x digital inputs. Up to 6x analogue inputs. -25 to +55°C -50 to +85°C
Part Numbers SM32-00: SM32-10: SM32-00-1U: SM32-10-1U: SM32-00-PM: SM32-10-PM:
Standard 1U modular controller, 3x relays, 6x digital inputs. Standard 1U modular controller, 3x relays, 6x digital inputs; with standard I/O expansion board mounted onto baseplate metalwork. Standard 1U x 19” mounting version controller, 3x relays, 6x digital inputs. Standard 1U x 19” mounting version controller, 3x relays, 6x digital inputs; with standard I/O expansion board. Standard panel mount version controller, 3x relays, 6x digital inputs. Standard panel mount version controller, 3x relays, 6x digital inputs; with standard I/O expansion board.
SM31 SUPERVISORY MODULE Input Voltage: Current: Interface Display: Communications: Serial: Relay: LVD: Indicators: 3x LED’s Audible: Controls: Signal Inputs: Alarms: Alarm Contacts: Default Alarm Map: Logging Capacity: Periodic Log: Event Log:
16-75V DC <150mA maximum.
4 line x 16 character multi-lingual alpha numeric display. 1x USB port on front panel for local PC interface. 3x alarm and control relays, two of which can be mapped for customized alarm settings. 3x standard or 2x pulse control LVD contacts. (for magnetically latched LVD contactors) Green - power on/monitor OK. Yellow - non urgent alarm. Red - urgent alarm. 90dBA buzzer mappable to user defined conditions. 3x push buttons for parameter setting or viewing on front panel. 2x serial buses for rectifier control and interface to peripheral modules. Fuse fail. 5x spare digital inputs. 2x temperature sensors. 3x current shunts. 2x DC voltage inputs. 3x alarm relays. 0.3A 100V volts free changeover contacts. Urgent. Non-urgent. Monitor fail.
126 LCD USB
serial control for up to 126 rectifiers/ converters plus peripheral devices.
lcd display.
usb port for local connection.
16384 records. (dependant on number of parameters logged.) 16384 records. (dependant on number of parameters logged.)
Physical Dimensions, W, H, D: Weight: Connections: Operating Temperature: Storage Temperature:
111.5mm , 44mm (1U), 282mm overall (rack depth 260mm) 1.5kg Relay outputs, mini combicon to accept 1.5mm csa wire. Serial communications to rectifier shelf & peripheral devices - RJ45. USB port - USB mini B. -25 to +55°C -50 to +85°C
Compliances Radiated Emissions: RF Susceptibility:
EN55022 EN55024
Optional Accessories ACA-TC3C: ACA-TC7C: ASM-AC3P: ASM-ABM-24: ASM-SM3XIO: Voltage Range: Current: Connection: Alarms: Signal Inputs: Operating Temperature: Storage Temperature:
3m temperature sensor and cable. 7m temperature sensor and cable. 3 phase AC voltage and current monitor. Battery condition monitor, 24 blocks. (maximum 4x BCM cards.) Standard I/O expansion board (maximum of 4 per supervisory module.) 15-75V DC <150mA maximum Connects via rectifier serial bus, 2x RJ45. Up to 8x alarm and control relays, able to be mapped for customized alarm settings. Up to 6x digital inputs. Up to 6x analogue inputs. -25 to +55°C -50 to +85°C
Part Numbers SM31-00: SM31-10: SM31-00-1U: SM31-10-1U: SM31-00-PM: SM31-10-PM:
Standard 1U modular controller, 3x relays, 6x digital inputs. Standard 1U modular controller, 3x relays, 6x digital inputs; with standard I/O expansion board mounted onto baseplate metalwork. Standard 1U x 19” mounting version controller, 3x relays, 6x digital inputs. Standard 1U x 19” mounting version controller, 3x relays, 6x digital inputs; with standard I/O expansion board. Standard panel mount version controller, 3x relays, 6x digital inputs. Standard panel mount version controller, 3x relays, 6x digital inputs; with standard I/O expansion board. ENATEL | 2010 PRODUCT CATALOGUE | 49
SM11 SUPERVISORY MODULE
TEMP LVD LCD temperature compensation.
lvd control.
lcd display of parameters.
Input Voltage: Current:
35-60V DC <85mA maximum.
Interface Display: Communications: Serial: Relay: Indicators: Controls: Signal Inputs: Alarms: Alarm Contacts: Alarm List:
6 character starburst. Interfaces with up to 6x RF series rectifiers. RS232 serial for downloading configuration files. 7x alarm and control relays. 8x LED. 3x push buttons for parameter setting on front panel. External shutdown. Fuse fail. Rectifier fail. Mains fail. Rectifier off normal. 2x voltmeter. 2x current meter. (100mV) 7x alarm relays. 1A 100V volts free changeover contacts. Off normal. Rectifier fail. Mains fail. Float high. Float low. LVD. (control line for external LVD contactor)
Physical Dimensions W, H, D: Weight: Connections: Operating Temperature: Storage Temperature:
275mm, 44mm (1U), 104mm 0.55kg Mini combicon to accept 1.5mm csa wire. -25 to +55째C -50 to +85째C
Versions SM11-12: SM11-24: SM11-48:
12V 24V 48V
Accessories Temp Sensor: ACA-TC2U: ACA-TC7U: Rectifier Interface: ACA-Alarm0.5: Current Sensor: ACS-S150:
2 metre temp sensor and cable. 7 metre temp sensor and cable. 500mm RJ45 patch cable. 150 Amp 100mV shunt assembly.
FAN CONTROLLER BOARD - Uses the SM3X temp sensor
The optional fan controller module allows the smart control of four 24V or 48V
fans with fan stall detection.
to control fan speed.
- Individual minimum fan speed
configurable to prevent fan stall.
- 4x fans controlled per module
and up to 2x modules per system.
Up to two fan controller modules can be connected in a system, giving a total of 8 controlled fans. Each module operates individually and has separate settings, so can have different temperature set points and operate at different speeds. The fans on one module all operate at the same speed.
50 | ENATEL | 2010 PRODUCT CATALOGUE
Input Voltage Range: Fan Voltage: Maximum Fan Current:
16-75V DC 12V, 24V, 48V & 60V DC 300mA maximum per fan connection.
Number Of Fans Controlled: Number Of Modules On Bus: Temperature Control Range: Communications: Alarms:
4x per fan controller module. (8x per system) 2x per system. The range of the SM3X temp sensor. Enatel serial bus interface. Controlled via SM3X fan fail.
Dimensions, W, H, D: Weight:
90mm, 67mm, 25mm 61g
Part Number: Fan Controller Board:
ASM-FCM4
BATTERY CONDITION MONITOR The Enatel BCM consists of peripheral circuit boards that can be added to an
- Compatible with SM22, SM32
Enatel system utilizing the SM22, SM32 or SM36 supervisory module to monitor
the performance of the installed stand-by battery system.
- 26 voltage inputs.
or SM36 supervisory modules.
- 8 pairs of current inputs. The monitor is designed to be connected to a number of different battery configurations with minimal changes to its configuration. The BCM includes the capability to log battery parameters during discharge and on a periodic time basis.
- 4 temperature inputs. - Discharge logging. - Periodic logging. - Ease of installation. - Compact design.
Voltage Resolution: Voltage Accuracy: Current Resolution: Current Accuracy:
0.01V ± 0.02V 1A ± 2A
Temperature:
± 2˚C (standard sensor, upgraded sensor available for ± 1˚C)
Standard Configurations:
4 8 1 1 8
Communications:
Enatel serial bus interface.
Alarms:
Controlled via SM22, SM32 or SM36. Voltage symmetry fault. (based on deviation from average string block measurement) Battery current imbalance. (based on deviation from average string current across all strings in system) Battery temperature high. Battery temperature low. Battery string open. (detects string voltage deviation from system DC bus to conclude battery is disconnected from system)
Data Logging: SM22: SM32:
Utilization of supervisory module memory: 15,500 data points. 196,000 data points. Actual number of discharge events stored depends on frequency of discharges, logging interval and parameters measured.
Mechanical Dimensions, W, H, D: Weight:
80mm , 145mm, 27mm 100g
Part Number Battery Condition Monitor:
ASM-ABM-24
strings, 4 voltage measurements per string. (requires 1x PCB) strings, 2 voltage measurements per string. (requires 1x PCB) string, 24 voltage measurements per string. (requires 1x PCB) string, 12 voltage measurements per string. (requires 1x PCB) string, 4 voltage measurements per string. (requires 2x PCBs)
AC MAINS MONITOR The AC mains monitor can be added to the SM range of supervisory modules if
- Compatible with SM range
AC supply metering is required.
of supervisory modules.
- Ease of installation. - Compact design. Communications:
Enatel serial bus interface.
Alarms:
Controlled via SM21, SM22, SM31, SM32, SM35 or SM36. Voltage phase high, voltage phase low, voltage phase lost. (separate alarms for each phase). AC phase current high. (common alarm for all phases) Frequency high, frequency low.
Mechanical Dimensions, W, H, D: Weight:
145mm, 15mm, 85mm 61.5g
Part Number AC Mains Mointor:
ASM-AC3P ENATEL | 2010 PRODUCT CATALOGUE | 51
FTTX POWER SOLUTIONS EPON INFRASTRUCTURE
SOHO / RESIDENTIAL APPLICATIONS
Enatel have recognised the need for DC Power Supplies specifically sized
The SOHO (Small Office/Home Office) and residential market is going to have
for Fibre to the Home requirements and developed a range of standalone and
the largest requirement for DC systems. If the customer premise is fitted
modular rectifiers and Micro Compact Power Shelves to suit every application
with alarms, nurse call or any other monitored device they will need a battery
within the FTTX environment. Be it Central Office or Customer Premise we
backed DC supply to ensure communication is available during an AC outage.
have the power solution to fit. Enatel have two solutions to suit these applications:
CENTRAL OFFICE APPLICATIONS
nSURE NS300-12
Experience shows that the majority of Central Office OLT units have a power
For the SOHO Client Enatel’s nSURE NS300-12 can provide long term
consumption of up to 1600W.
backup for all their communications needs.
Enatel’s Micro Compact Power System is perfect for this application having
SOHO (Small Office/Home Office) clients with security systems will need
3 x 800W rectifiers gives an N+1 redundancy solution, built in distribution
Enatel’s nSURE NS300-12 power supply. Couple into this the ONU, Security
and full configured Supervisory Module.
system, residential gateway and wireless router and it can be business as usual from a laptop during an AC outage. The NS300-12 is wall mountable
OFFICE / APARTMENT APPLICATIONS
and convection cooled making it ideal for office locations. - 12V, 300W output.
These ONT’s range in power consumption from 60W to 500W, typically have
- Mains fail alarm.
dual DC feeds and are 19” rack mountable.
- Convection cooled. - Wall mountable.
Enatel’s Micro Compact range with 200W and 400W modules are purpose
- Automatic float/boost charge cycle.
built for this application, giving optimum power output with space for
- Power factor corrected.
redundancy and standby battery recharge in the event of an AC failure.
- Thermally protected.
MICRO COMPACT POWER SYSTEM
- Input/output voltage and current protected.
nSURE NS30-12 Enatel’s new range of Micro Compact Power Systems utilize Enatel’s intelligent controllers and modular rectifiers. With rectifier output ratings
To suit the residential needs Enatel offers the nSURE NS30-12 (with
of 200, 400 and 800W and Supervisory modules capable of Ethernet
integrated battery) for basic autodialer backup functionality.
communication as standard these 1U power shelves are ideal for FTTX solutions. They offer output power in line with the OLT /ONU usage and
For home owners with alarm auto dialers FTTH means their alarms will not be
have the capacity for N+1 redundancy. With various output distribution
monitored in the event of an AC Outage. Enatel’s nSURE NS30-12 provides
options they cater to all the requirements of this growing market.
battery backed power to the ONU even when the lights go out. Security or Nurse call devices will operate as normal.
- Micro compact size means more room
for revenue generating equipment.
- Telecom grade 12V DC (30W max.) output.
- World leading power density.
- Up to 8 hours* of standby battery backup.
- Fully featured telecom grade rectifiers.
- Flexibility of wall or desktop mount.
- Network monitoring available. - Modular 19”/515mm ETSI design for ease of installation. - High reliability means less cost of maintenance. - Full remote monitoring available
means less site visits and less cost.
- Easily customized and configured to
- Easy user replaceable battery without power interruption. - Microprocessor based intelligent control. - Cold start capable. - Local audible and visual indicators with remote alarms. - Optional extended runtime.
suit each customers individual needs.
AC POWER SOLUTIONS As some FTTX equipment is AC powered Enatel can also offer integrated DC-AC Inverters, this allows for a telecommunications grade UPS (Long backup times) on the entire FTTX system. The Inverters are monitored and controlled through the same controller as the rest of the DC Power system. Enatel can supply the complete solution in a wall mount cabinet or ready to integrate into the OLT/ONU mounting system. 52 | ENATEL | 2010 PRODUCT CATALOGUE
nSURE 1U MICRO COMPACT SYSTEM 0.8 - 2.4KW 48V DC AC Input:
Single phase.
AC Current:
170V AC, 15.0A max. 230V AC, 11.1A nominal.
(refer to RM8xx, series brochures for full details)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full load)
Termination:
Single phase, 1.5m flying lead.
48 2.4
V
nominal output voltage.
DC Output Nominal Voltage:
-48V
Rated System Output Power:
2400W max. (50A @ -48V; 44.4A @ -54.0V)
Polarity:
Positive earth. (negative earth available to special order).
kW
maximum output power.
DC Distribution:
Load:
2x 10A, 2x 20A load circuit breakers.
Battery:
2x 30A battery circuit breakers. Supervisory Module
SM36
Breaker Fail Detection:
RM848
RM848
RM848
Electronic fail detection on both load and battery breakers.
DC Terminals (Front Connected):
Load:
6mm² push-in spring cage.
Battery:
55A power-pole plug-in connectors..
Low Voltage Disconnect:
50A battery LVD (magnetically latching) fitted as standard.
Mechanical Dimensions, W,H,D:
482.6mm (standard 19” module), also fits
ETSI 515mm mounting cabinet, 44.45mm (1U, 1.75”), 285mm (11.6”)
Weight:
5kg (excluding rectifier modules)
Shipping Dimensions, W,H,D: 540mm, 95mm, 400mm Weight:
6kg (excluding rectifier modules)
Monitoring & Control:
Various monitoring options are available via the Enatel SM35/36 series
of control & supervisory modules. Standard features include full
temperature compensation, automated and manual battery testing/
equalisation, 6x general purpose inputs and 6x voltage-free relay alarm
outputs. For further details, refer to the SM35/36 series of brochures.
Accessories ACA-BC08P2:
2m, 8mm Ø battery cable kit. (other lengths available to special order)
Part Numbers:
Actual part numbers will vary with configuration.
PSX1606211F-000:
Micro compact system, 2x 800W 48V rectifiers, 6x load
2x battery MCB’s, front termination, SM35 supervisory module.
PSX1606221F-000:
Micro compact system, 2x 800W 48V rectifiers, 6x load
2x battery MCB’s, front termination, SM36 supervisory module.
PSX2404211F-000:
Micro compact system, 3x 800W 48V rectifiers, 4x load
2x battery MCB’s, front termination, SM35 supervisory module.
PSX2404221F-000:
Micro compact system, 3 x 800W 48V rectifiers, 4x load
2x battery MCB’s, front termination, SM36 supervisory module. ENATEL | 2010 PRODUCT CATALOGUE | 53
nSURE NS300-12
12 300 V
nominal output voltage.
maximum output power.
W
54 | ENATEL | 2010 PRODUCT CATALOGUE
AC Input Nominal: Voltage Range: Frequency Range: Power Factor: Efficiency: Input Fuses: Maximum Input Current: Protection: Input Voltage: Input Rush: DC Output Nominal Voltage: Rated Voltage: Voltage Range: Maximum Current: Regulation: Line: Load: Hold-up Time: Start-up Time: Protection: Current Limit: Over Temp: Polarity Reversal: Over Voltage: Noise: (under nominal conditions) Ripple <100Hz: Voice Band 100Hz to 5KHz: Wide Band 5kHz to 1 MHz: Peak to Peak 0 to 20MHz: Isolation: Input to Output: Input to Chassis: Output to Chassis: Environmental Requirements Nominal Ambient Temperature: Range: Humidity: Altitude:
110/220V, 50/60Hz 100-275V AC (full power output), 85-100V AC (reduced power output) 45-66Hz >0.99 (full load) 85% HRC Fuses in phase & neutral. 4A Automatic shutdown, restarts automatically when correct voltage restored. <2x maximum input current.
12V 14.5V 11.5-15V 20A ±0.1% ±0.5% (no load to full load) >15ms for 20% output voltage drop. Walk-in delay 2 seconds (depends on AC input voltage) Adjustable to 50-100% of maximum rated current. Automatic current turndown, backup shutdown protection. Output fuse with crowbar diode. Adjustable limit. <5mV rms unweighted. <0.5mV rms psophometric. <2.5mV rms unweighted. <50mV p-p unweighted. 3000V AC 2500V AC (VDR to chassis removed.) 1500V AC
25+/-5°C -10 to +60°C 5-95% RH (non-condensing) <2500m de-rate maximum ambient temperature by +4˚ per 1000m above sea level.
Mechanical Dimensions, W, H, D: Weight: Shipping Dimensions, W, H, D: Shipping Weight: Cooling: Connections: Mains: Output to Load: Output to batteries:
IEC 320 universal connection. 4 way lumberg macromodule. 4 way lumberg macromodule.
Standard Features Auto Float/Boost: Alarm and Indicator Controls:
Rectifier enters boost mode at power up. When battery current reduces to float threshold limit (adjustable from 0.1A to 40% MRC), unit reverts to float voltage setting. When in boost but out of current limit, rectifier will automatically switch back to float after approximately four hours. If battery current exceeds the float threshold limit when the rectifier is in float mode it will automatically switch to boost mode. Open collector rectifier fail (via 4k7 resistor), Open collector mains fail.
Compliances: Safety: EN60950 Electrostatic Discharge: Radiated Radio Frequency: AC Harmonics: AC Flicker and Fluctuation:
CISPR24 CISPR22 EN61000-3-2 EN61000-3-3
311mm, 163mm, 62mm 1.5kg 377mm, 235mm, 122mm 2.4kg Convection cooled.
nSURE NS30-12 Input Nominal Input Voltage:
120V AC/230V AC
Voltage Range:
80-260V AC
Frequency Range:
45Hz-65Hz
Plug Type: IEC inlet.
Output Output Power (Max):
30W/2.2A
Normal Voltage:
12V DC
Output Voltage Range:
10.5-13.8V DC
Line Mode Efficiency:
>80%
12 30
V
nominal output voltage.
W
maximum output power.
Plug Type: 7pin terminal strip. (2 * DC output, 5 * dry contact alarms)
Battery Type/Rating:
12V/7Ah x 1pc (12V/9Ah option)
Discharge Prevention:
10.5V ± 0.5V
Rated Charging Voltage:
13.7V ± 0.25
Recharge Time (Internal Battery):
4 hours to 90% without load after discharge.
Charge Current:
2.5A maximum.
Hot Swappable Battery:
Yes.
Indicators AC Mode:
Solid green LED.
Backup Mode:
Solid yellow LED.
Battery Low:
Flashing yellow LED.
Battery Replace:
Flashing red LED.
Battery Missing:
Flashing red LED.
Fault:
Flashing red LED.
Battery Self Test:
Flashing green LED.
Audible Alarm Backup Mode:
5 seconds.
Battery Low:
1 second.
Battery Replace:
2 seconds.
Battery Missing:
Continuous.
Fault:
Continuous.
Mute Function:
Switch. (on/off)
Environment Operating Temperature:
0 to 40°C
Operating Humidity:
0 to 90%
Operating Elevation:
0 to 3000m
Physical Dimensions, W, H, D:
212mm, 216mm, 87mm
Weight:
4.0Kg ENATEL | 2010 PRODUCT CATALOGUE | 55
INDUSTRIAL SOLUTIONS - World leading power density.
Based on our proven range of modular telecom power solutions, we have
- Fully featured telecom
developed a range of solutions for use in 110V DC industrial applications.
grade rectifiers.
- Network monitoring available.
Systems are configured using Enatelâ&#x20AC;&#x2122;s state of the art high frequency switch
- Modular 19â&#x20AC;? design for ease
mode rectifier modules, intelligent network capable controllers, AC & DC
of installation.
- Includes AC surge protection. - More room for revenue
creating equipment.
- Upgrade existing systems
to higher power.
- High reliability means less cost
of maintenance.
- Full remote monitoring available
means less site visits and less cost.
- Cost competitive. - Suitable for more harsh
environments.
56 | ENATEL | 2010 PRODUCT CATALOGUE
distribution modules, and cabinets, and can be customized and configured to meet individual customer requirements. For details on a Enatel power system that meets your requirements contact us.
2U ULTRA COMPACT SYSTEM 3.0 - 6.0kW 110V DC AC Input:
Single phase 90 – 300V AC
AC Current:
38A max / Ph (Ph-N) (refer to RM30110 brochure for full details)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full load)
Termination:
Single phase, 16mm2 L, N, E tunnel terminals at rear.
Single phase surge protection. (40kA, 8/20µ sec)
110 6.0
V
nominal output voltage.
kW
DC Output Nominal Voltage:
121.5V
Rated Voltage:
80-155V DC
Rated System Output Power:
6.0kW max @ 121.5V DC (50A)
+60V / -60V
maximum output power.
Supervisory Module
SM34
Polarity:
AC Input
Load
Battery
ULTRA
compact
HV
DC Distribution:
Load:
1x 63A 2 pole load MCB (breaks +ve & -ve)
35mm tunnel terminals at rear.
1x 63A 2 pole battery MCB (breaks +ve & -ve)
Battery:
35mm tunnel terminals at rear.
Breaker Fail Detection:
Auxiliaries on both load and battery breakers.
Earth Leakage Detection:
Configurable via software, factory set at 25mA
Mechanical Dimensions, W, H, D:
482.6mm (standard 19” module), 89mm (1U, 3.5”), 415mm (16.3”)
Weight:
7.5kg (excluding rectifier modules)
Shipping Dimensions, W, H, D: 530mm, 154mm, 430mm Weight:
9kg (excluding rectifier modules)
Monitoring & Control:
Various monitoring options are available via the Enatel SM33/34 series of
control & supervisory modules. Standard features include full temperature
compensation, automated and manual battery testing/equalisation and
three voltage-free relay alarm outputs.
Part Numbers:
Actual part numbers will vary with configuration.
PSC06021130-000:
2U HV Ultra Compact Power System
including standard SM33 supervisory module.
PSC06021140-000:
2U HV Ultra Compact Power System
including standard SM34 supervisory module. ENATEL | 2010 PRODUCT CATALOGUE | 57
WALL MOUNT BATTERY CHARGER 3.0kW 110V DC
110 3.0 nominal output voltage.
maximum output power.
V
kW
AC Input:
Single phase with surge protection and input 32A MCB
(refer to rectifier brochure for full details)
Frequency Range:
45-66Hz
Power Factor:
>0.99 (full load)
Termination:
Single phase. Direct MCB termination for L. 10mm² N, E tunnel terminals.
Max Rated System Output Power:
110V (80-155V DC)
3000W @ 120V DC, 27A max.
Polarity:
Isolated output. 1x RM30110 3000W rectifier.
DC Distribution:
Load:
1x 63A 2 pole MCB.
Battery:
1x 63A 2 pole MCB.
Breaker Fail Detection:
Auxiliaries.
DC Terminals:
Live: Direct MCB connections.
Weight:
Approx. 10.5Kg
Dimensions, D, H, W:
620mm x 375mm x 80mm
Shipping Dimensions, D, H, W: 730mm x 470mm x 200mm
58 | ENATEL | 2010 PRODUCT CATALOGUE
Monitoring and Control:
Various monitoring options via the Enatel SM30 series of control &
supervisory modules. Standard features include full temperature
compensation, automated and manual battery testing/equalisation
and three voltage-free relay alarm outputs. For further details,
refer to the SM30 series of brochures.
Part Numbers:
Actual part numbers will vary with congifuration.
PSW-3111030-000:
Wall mount charger including standard SM33 supervisory module.
PSW-3111040-000:
Wall mount charger including standard SM34 supervisory module.
RM30110 3.0KW 110V DC MODULAR RECTIFIER AC Input Nominal: Voltage Range: Frequency Range: Power Factor: Efficiency: Input Fuses: Maximum Input Current: Protection: Input Voltage: Input Inrush:
230V 90-300V (reduced power below 175V) 45-65 Hz >0.99 >92% (>45% output power) HRC fuses in phase and neutral. 19A Auto shutdown, auto restart when correct voltage restored. <2x maximum input current.
DC Output Output Ratings: Constant Current: 80-110V DC (27.3A) Constant Power: 110-155VD C (3.0kW) Nominal Voltage: 120V Rated Voltage: 145V Voltage Range: 80-155V Maximum Current: 27.3A Regulation: Line: ±0.1% ±0.5% (no load to full load) Load: Hold-up Time: >15ms for 20% output voltage drop. Start-up Time: Start up delay 1 second. (varies with AC supply voltage) Walk-in delay 6 seconds at full output. (varies with DC output voltage) Protection: Current Limit: Adjustable to 50-100% of maximum rated current. Automatic current turndown, backup shutdown protection. Over Temperature: Polarity Reversal: Output fuse with crowbar diode. Over voltage: Adjustable limit. Noise: (under nominal conditions) Ripple <100Hz: <1mV rms unweighted. Voice band 100Hz-5KHz: <2mV rms psophometric. Wide band 5kHz-1MHz: <5mV rms unweighted Peak to Peak 0-20MHz: <200mV peak to peak. Isolation: Input to Output: 4000V DC Input to Chassis: 3500V DC (VDR to chassis removed) Output to Chassis: 2100V DC Environmental Requirements Ambient Temperature: Nominal: Range: Storage Temperature: Humidity: Altitude:
110 3.0 27.3
V
nominal output voltage.
kW
nominal output power.
A
maximum output current.
25+/-5ºC -10ºC to +70ºC (maximum output power is derated above +50ºC) -20ºC to +70ºC 5-95% RH (non-condensing) <2500m, De-rate maximum ambient temperature by 4ºC per 1000m above sea level.
Mechanical Dimensions, W, H, D: 41mm, 220mm, 305mm overall. Weight: 2.8kg Shipping Dimensions W, H, D: 52mm, 230mm, 340mm Shipping Weight: 2.95kg Cooling: Forced cooled, using dual temperature controlled high reliability fans. Compliances Safety: Electrostatic Discharge: Radiated Radio Frequency: AC Harmonics: AC Flicker and Fluctuation:
EN60950 CISPR24 CISPR22 EN61000-3-2 EN61000-3-3
Other:
CE & RoHS compliant. ENATEL | 2010 PRODUCT CATALOGUE | 59
SM34 SUPERVISORY MODULE
LVD WEB USB dual lvd control.
web based configurator.
usb port for local connection.
Input Voltage:
80-160V DC
Current:
<50mA maximum.
Interface Display:
4 line x 16 character multi-lingual alpha numeric display.
Communications:
Serial:
1x USB port on front panel for local PC interface.
1x RS232 port, rear mounted for remote serial/modem communications.
3x alarm and control relays, two of which
Relay:
can be mapped for customized alarm settings.
TCP/IP:
Ethernet interface for communication using SNMP
protocol and internal web based configurator.
LVD:
3x standard or 2x pulse control LVD contacts. (for magnetically latched LVD contactors)
Indicators:
3x LED’s
Green - power on/monitor OK.
Yellow - non urgent alarm.
Red - urgent alarm.
90dBA buzzer mappable to user defined conditions.
Audible:
Controls:
3x push buttons for parameter setting or viewing on front panel.
Signal Inputs:
Serial bus for rectifier control and interface to peripheral modules.
Fuse fail.
5x spare digital inputs.
2x temperature sensors.
3x current shunts.
2x DC voltage inputs.
Alarms:
3x alarm relays.
Alarm Contacts:
0.3A 100V volts free changeover contacts or
0.15A 160V volts free changeover contacts.
Default Alarm Map:
Urgent.
Non-urgent.
Monitor fail.
Logging Capacity:
Periodic Log:
16384 records. (dependant on number of parameters logged.)
Event Log:
16384 records. (dependant on number of parameters logged.)
Physical Dimensions, W, H, D:
111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)
Weight:
1.5kg
Connections:
Relay outputs, mini combicon to accept 1.5mm csa wire.
Serial communications to rectifier shelf & peripheral devices - RJ45.
USB port - USB mini B.
Operating Temperature:
-25 to +55°C
Storage Temperature:
-50 to +85°C
Compliances Radiated Emissions:
EN55022
RF Susceptibility:
EN55024
Optional Accessories ACA-TC3C:
3m temperature sensor and cable.
ACA-TC3C:
7m temperature sensor and cable.
ASM-AC3P110:
3 phase AC voltage and current monitor.
ASM-ABM-24:
Battery condition monitor, 24 blocks. (maximum 4x BCM cards.)
Part Numbers
60 | ENATEL | 2010 PRODUCT CATALOGUE
SM34-00:
Standard 1U modular controller, 3x relays, 6x digital inputs.
SM34-00-1U:
Standard 1U x 19” mounting version controller, 3x relays, 6x digital inputs.
SM34-00-PM:
Standard panel mount version controller, 3x relays, 6x digital inputs.
SM33 SUPERVISORY MODULE Input Voltage:
80-160V DC
Current:
<50mA maximum.
Interface Display:
4 line x 16 character multi-lingual alpha numeric display.
Communications:
Serial:
1x USB port on front panel for local PC interface.
Relay:
3x alarm and control relays, two of which
can be mapped for customized alarm settings.
3x standard or 2x pulse control LVD contacts.
LVD:
(for magnetically latched LVD contactors)
Indicators:
3x LED’s
Green - power on/monitor OK.
Yellow - non urgent alarm.
Red - urgent alarm.
90dBA buzzer mappable to user defined conditions.
Audible:
Controls:
3x push buttons for parameter setting or viewing on front panel.
Signal Inputs:
2x serial buses for rectifier control and interface to peripheral modules.
Fuse fail.
5x spare digital inputs.
2x temperature sensors.
3x current shunts.
2x DC voltage inputs.
Alarms:
3x alarm relays.
Alarm Contacts:
0.3A 100V volts free changeover contacts or
0.15A 160V volts free changeover contacts.
Default Alarm Map:
Urgent.
Non-urgent.
Monitor fail.
126 LCD USB
serial control for up to 126 rectifiers/ converters plus peripheral devices.
lcd display.
usb port for local connection.
Logging Capacity:
Periodic Log:
16384 records. (dependant on number of parameters logged.)
Event Log:
16384 records. (dependant on number of parameters logged.)
Physical Dimensions, W, H, D:
111.5mm , 44mm (1U), 282mm overall (rack depth 260mm)
Weight:
1.5kg
Connections:
Relay outputs, mini combicon to accept 1.5mm csa wire.
Serial communications to rectifier shelf & peripheral devices - RJ45.
USB port - USB mini B.
Operating Temperature:
-25 to +55°C
Storage Temperature:
-50 to +85°C
Compliances Radiated Emissions:
EN55022
RF Susceptibility:
EN55024
Optional Accessories ACA-TC3C:
3m temperature sensor and cable.
ACA-TC7C:
7m temperature sensor and cable.
ASM-AC3P110:
3 phase AC voltage and current monitor.
ASM-ABM-24:
Battery condition monitor, 24 blocks. (maximum 4x BCM cards.)
Part Numbers SM33-00:
Standard 1U modular controller, 3x relays, 6x digital inputs.
SM33-00-1U:
Standard 1U x 19” mounting version controller, 3x relays, 6x digital inputs.
SM33-00-PM:
Standard panel mount version controller, 3x relays, 6x digital inputs. ENATEL | 2010 PRODUCT CATALOGUE | 61
62 | ENATEL | 2010 PRODUCT CATALOGUE
Š Copyright Enatel Limited 2010. Due to product development specifications are subject to change without prior notice. Pictures may be representative, actual products may differ.
321 Tuam Street PO Box 22-333 Christchurch New Zealand
Phone +64-3-366 4550 Fax +64-3-366 0884 Email sales@enatel.net www.enatel.net