Laura Graden Portfolio 2013

Page 1


Laura graden portfolio Laura.graden@gmail.com

208.521.8442

35 Rotary Ave. Binghamton, NY 13901

02 04 06 08 12 14

MREC sustainable lab Legacy Crossing Fire Station M.ARCH Thesis CADD Samples Graphic Design

Cover Image: CiGi Campus, Canada: KPMB Architects, Toronto Photo: Maris Mezulis


Sustainable Principles: Extensive Green Roof A lightly seeded green roof helps mitigate solar heat gain, filters storm water for collection, and helps prevent excess stormwater runoff. The cooler temperatures can increase the efficiency of photovoltaics, while the plantings provide habitat for native species of birds and insects.

Brise Soleil Low energy glass allows the transmission of sunlight, but not heat. The system mimics a Double- Skin Facade, which cools passively by circulating warm air past the facade, pulling warm air from the interior.

Occupancy Sensor Lighting Lighting that operates only when a space is occupied prevents overuse of electricity. Lights in day lit spaces can be set to auto-dim when the lighting levels are sufficient with daylight alone.

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

Storm + Grey Water Re-use Stormwater runoff can be used in toilets or for non-potable applications in a building. Grey water, such as that used for washing hands, can also be re-used or processed on-site through a wetland, preventing over dependence on the sewer system.

Non- Hazards lab Bio + Chem Lab

Office

Second Floor PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

Learning LAb 1 Computing

Learning LAb 2

Except for the laboratories, which have strict air quality and humidity constraints, the building is cooled using hydronic radiant-in-floor cooling, which not only is more energy, efficient, it also improves indoor air quality. Heating is not required in this climate.

1

2

4

3

Facade Perforation Development Trabeculae: The facade pattern is derived from an image of Acropora Millepora, or Pacific Coral, a species indigenous to the Salt River Bay.

Mech Collections/ Research

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

Storage

First Floor

02

Radiant Floor Cooling

Bio+Chem lab

Marine Research Education Center Sustainable Lab

St. Croix, US Virgin Islands

This lab was funded as part of a Sustainable Laboratory competition challenging students to design a Net-Zero, Carbon Neutral Marine Biology lab serving the MREC institute on the island of St. Croix, in the US Virgin Islands. The lab provides “wet lab” space for processing marine tissues, as well as support services, student laboratories, offices, and computing labs.

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

Dry Lab

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

Storage Storage

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

1st floor Hall

Dorm

Collections library lab loading dock

view from Administrative Building

admin


sixth street plaza

Legacy Circle apartments

Restaurants Dwelling Units

Parking

100 x7 x90+ x223 x

Hotel Rooms

Sixth Street

Grocery Apartments

Transit & Service

typ. Studio

20

Deluxe Studio 2 bed

9

7

F. E.

F. E.

1

4

5

55

Courtyard Hotel New H. R. Building 100 141

6

3

Legacy Crossing master plan

Live- Work Units 14

Corner of Sixth + Jackson, Moscow, ID

This collaborative project developed a phased master plan for a crucial junction between the University and downtown known as Legacy crossing. Currently, the site is a brownfield; the site of an old rail station and grain elevators used for processing the area’s wheat and lentils. I was responsible for the design of the Legacy Circle apartments, in conjunction with rendering all the images shown, and rendering the site plan.

26

Conference Center

36

Ground Floor

04

St. Auggies

ion

8

Grocery/ Convenience Open Retail Mechanical Rooms Lobby Resident Mail desk Rental Office Live-Work Studios Public Restrooms Medical Office

ens

1 2 3 4 5 6 7 8 9

Grain Silo Theatre

ext

1 bed

Second Floor Typ.

2

ury

Lounge

2 bed

er elt Sh s Bu

Legacy Circle Mixed-income Apts

asb

Ground Floor amenities: 2 bed

aCc ess On ly

new Bookstore + Post Office 1 bed

Mixed Use

University Pointe

20

ve hA t h Eig


View from Front St.

Lobby Second floor

key:

OPEN TO BELOW

3

1

1 conference Room 2 Open Offices 3 Roof Deck 4 vehicle maintenance 5 truck bays & Gear-up 6 Living quarters 7 firefighter lounge 8 private courtyard 9 kitchen 10 exercise room 11 lobby 12 Training Tower

2 OPEN TO BELOW

First floor 6

10

8

12

Exploded axon Detail @ window

1 4

5 7 9

06

Boise Fire Station 5

11

212 South 16th Street, Boise ID

The station was designed using CMU as a prominent material for the Idaho Concrete Masonry Association annual design competition. It was one of 10 finalists out of almost 50 entries. The project mitigates many challenges, including the nearby freeway interchange sheltering a homeless population, requiring a careful interface between public and private to maintain the privacy of the resident firefighters while still promoting the Civic nature of a fire station.

15th Street elevation


guiding principles Tactility: The focus for this project was to combine digital and analog media resulting in a final, buildable project. Accessibility: Universal design issues to consider include ease of construction, portability, and maneuverability of the structure or pieces of the structure, as well as universal access.

Flexibility: Ideally, folded structures are some of the most responsive and flexible structures in regards to

environmental and temporal stimuli. These issues include the range of motion of finished design, which can accommodate not only programmatic changes, but lighting, ventilation and seasonal changes as well.

Sustainability: Folded architectural forms can help prevent material and resource waste, if properly positioned and tessellated across the raw material. A larger tesselation allows more efficient material usage. Flatpacking building elements can reduce shipping bulk, waste and cost. In the case of this particular project, and area approximately 300 cubic feet can be condensed to less than 2 cubic feet when the panels are flattened. The original parameters required over 100 completely unique units, which is not sustainable. Using the geometries as the main parameter, only 4 unique panel types were required. Parametric design is a powerful generative tool, but it rarely results in materially efficient fabrication methods, which has problematic implications for sustainability, and lifetime cost of a structure.

Structure: From the folding studies, I discovered that folded paper is strongest in compression, but this

Scan for Full Project Report

design utilizes the folds in tension. While most of the structural capacity comes from the tabs, which act as structural ribs, the miscalculations in the connection angles greatly reduce the load-bearing capacity of these tabs. These gaps keep an otherwise stable structure from being completely self-supporting. I believe if the tabs were correctly calculated and able to be secured, that these stability issues would resolve. If the structure was made of wood, these issues would not occur; however the mitering and precise calculations required for each panel to fit exactly would also prevent quick or easy construction.

tesselation diagrams

folds into

08

M. ARCH Thesis Project

Material Sustainability in Parametric Design Ridenbaugh Art Gallery, Moscow, ID

STATUS: Temporary Installation, Currently not constructed MATERIALS: Wax coated paperboard, Nylon cable ties, Pine supports, RHINO 3D w/ Grasshopper. Found object chair COST: $100 SQ. FOOTAGE: 36


Final Grasshopper Definition

Construction

Supplies

Creasing panels

Stacked units

Assembled base units

Securing tabs

Fabrication methods These layouts show the break down of the full-scale panels as required by the max material sizes of the laser cutter used for fabrication. The paper was donated in 24x36 sheets, which were cut in half to fit the Universal 460 Laster cutter’s max dimensions of 18x24. The panels were broken down to fit these dimensions. As is evident, quite a bit of material waste is created at the panel edges.

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

Final Pictures

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

Securing zip ties

PRODUCED BY AN EDUCATIONAL PROD PRODUCED BYAUTODESK AN AUTODESK EDUCATIONAL P

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

Hanging suspension hardware

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

Lighting Module

PRODUCED BY AN EDUCATIONAL PROP PRODUCED BYAUTODESK AN AUTODESK EDUCATIONAL

Scale Physical Model

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

BY EDUCATIONAL PRODUCT EDAN BYAUTODESK AN AUTODESK EDUCATIONAL PRODUCT

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

Example Setting in a Library

Base unit attached base


AWNING SILL @ CMU W/ EIFS PRECAST SILL

ALUMINUM SILL CASEMENT HEAD @ CFMF W/ BRICK VENEER

HEAD

HEAD

ALUMINUM AWNING WINDOW AS SPECIFIED SEALANT AT SILL, BOTH SIDES

UTILITY MASONRY VENEER

8/ 10" CMU

EIFS AS SPECIFIED PRECAST SILL WITH DRIP EDGE

P-LAM, OR WOOD WINDOW STOOL

SHEET METAL FLASHING

ALUMINUM THRUWALL FLASHING EIFS APPLIED AS SPECIFIED

3 5/8" CFMF STUD WALL 16" O.C.

P-LAM, OR WOOD WINDOW STOOL

5/8" ABUSE RESISTANT GWB CAVITY VENT @ 24" O.C.

SHEET METAL FLASHING

8/ 10" REINF. CMU 5/8" GWB LINTEL, GROUTED FULL

STEEL ANGLESREFER TO STRUCTURAL DRAWINGS FOR SIZES. SEALANT BOTH SIDES

C-CHANNEL HEADER

ALUMINUM THRUWALL FLASHING

ON 7/8" METAL FURRING

5/8" GWB ON 7/8" METAL FURRING

STEEL PLATE WELDED TO NEW DOOR HEAD ANGLES. FINISH AS SCHEDULED. SEE STRUCTURAL DRAWINGS FOR SIZES.

SHIM AS REQ. DOOR & FRAME AS SCHEDULED

CORNER BEAD

CONT. SEALANT

CASEMENT SILL @ CFMF W/ 8"BRICK VENEER 1x1CMU SNAP TRIM OR 10" WALL

EIFS APPLIED AS SPECIFIED

SHIM AS REQ'D

8" OR 10" CMU WALL

CONT. SEALANT

LOOSE-LAID LINTEL

ALUMINUM AWNING WINDOW UNIT, AS SPECIFIED

1

ALUMINUM CASEMENT WINDOW AS SPECIFIED

SEALANT & BACKER RODS (BOTH SIDES)

ALUMINUM FRAME & SILL

SEALANT & BACKER RODS (BOTH SIDES)

CONTINUOUS SEALANT (BOTH SIDES) HOLLOW METAL DOOR FRAME

SEALANT AT INTERIOR SILL, BOTH SIDES

AIRSPACE DRAINAGE MAT ON 1 1/2" RIGID INSULATION

PRECAST SILL WITH DRIP EDGE

AIR BARRIER AS SPECIFIED

METAL STUDS BOX HEADER WITH INSULATION

LIQUID-APPLIED AIR BARRIER AS SPECIFIED

ALUMINUM AWNING WINDOW AS SPECIFIED

HM DOOR 2 HR RATING @ HEAD N.T.S

2

HM DOOR @ EXPANSION JOINT @ HEAD N.T.S

ALUMINUM SILL FRAME, BRICK SILL

EIFS SILL SILL

1/2" EXTERIOR PLYWOOD SHEATHING ALUMINUM CASEMENT WINDOW

ALUMINUM CASEMENT WINDOW AS SPECIFIED

ALUMINUM AWNING WINDOW AS SPECIFIED AS SPECIFIED

AWNING HEAD @ CMU W/ EIFS

UTILITY MASONRY VENEER

SEALANT AT INTERIOR STOOL, BOTH SIDES

AIRSPACE DRAINAGE MAT ON 1 1/2" RIGID INSULATION

SHIM AS REQ'D

WEATHER BARRIER

ALUMINUM SNAP TRIM

PRECAST SILL WITH DRIP EDGE

ALUMINUM P-LAM, OR WOOD WINDOW STOOL SNAP TRIM

ALUMINUM FLASHING

CAULK- COLOR TO MATCH WALL COLOR

SHEET METAL FLASHING

SINGLE/ DOUBLE HUNG SILL @ CMU W/ BRICK VENEER

P.T. FURRING SEALANT

CAULK- COLOR TO MATCH WALL COLOR

MASONRY OR PRECAST CONCRETE SILL

SEALANT

2X P.T. BLOCKING

2x BLOCKING ALUMINUM THRUWALL FLASHING

5/8" GWB INVERTED C- CHANNEL SILL PLATE ON 7/8" METAL FURRING

UTILITY MASONRY VENEER

EIFS APPLIED AS SPECIFIED

FRAME EXTENDER/ FLASHING SET IN CONTINUOUS SEALANT BED AGAINST SILL

ALUMINUM SINGLE HUNG WINDOW AS SPECIFIED (DOUBLE HUNG SIMILAR)

BATT INSULATION R= ON 3 5/8" CFMF STUD WALL

1/2" EXTERIOR GRADE SHEATHING

8" OR 10" CMU WALL

WEATHER BARRIER TAPE

5/8" GWB RIGID INSULATION R=

5/8" GWB

1/2" EXTERIOR GRADE SHEATHING

3 5/8" CFMF STUD WALL W/ BATT INSULATION R=

CASEMENT JAMB @ CFMF W/ BRICK VENEER

INSECT SCREEN

JAMB

SEALANT BOTH SIDES

WINDOW STOOL

PRECAST SILL

JAMB

EIFS MFR APPROVED SEALANT W/ BACKER ROD

WOOD FRAME CASEMENT WINDOW VAPOR/ AIR BARRIER AS SPECIFIED.

SILLWINDOW BELOWSTOOL PROFILE WILL VARY

1x1 ALUMINUM TRIM 2X P.T. BLOCKING

1

2

ALUMINUM THRUWALL FLASHING

1/2" GWB

3 5/8" CFMF STUD WALL W/ BATT INSULATION R=

1/2" EXTERIOR GRADE SHEATHING

SHIM AS REQ'D

D.H. WOOD FRAME WINDOW AS SPECIFIED

WINDOW STOOL PROFILE WILL VARY

2X P.T. BLOCKING

N.T.S

6" CFMF STUD WALL W/ BATT INSULATION R=

HEAD

3 5/8" CFMF STUD WALL W/ BATT INSULATION

R=

SHIM AS REQ'D

HEAD

2X DOUBLE SILL PLATE

4

N.T.S

DOUBLE HUNG WINDOW IN CMU W/ BRICK @ SILL N.T.S

CFMF 3 5/8" STUDS 16" O.C.

JAMB

METAL PANEL & ASSOC. FRAMING AS SPECIFIED

5/8" ABUSE RESISTANT GWB

BATT OR BLOWN IN INSULATION AS SPECIFIED

CFMF BOX HEADER

1/2" GYPSUM WALL BOARD

fiber cement siding (WOOD/ FIBER CEMENT/ VINYL/ ALUMINUM) SIDING ON 1/2" EXT. PLYWOOD SHEATHING

WF EXT. DOOR @ HEAD

SLIDING HEAD @ CFMF W/ METAL PANEL

ALUMINUM FRAME

ALUMINUM TRIM

3

1/2" EXTERIOR GRADE SHEATHING

FIXED HEAD @ WLF W/ SIDING FIXED ALUMINUM WINDOW UNIT BATT INSULATION AS SPECIFIED

1/2" GYP. BOARD WALL

ALUMINUM CASEMENT WINDOW5/8"@ CFMF W/ BRICK GWB

ALUMINUM THRUWALL FLASHING LAP OVER AIR BARRIER

CONTINUOUS SEALANT- BOTH SIDES GROUT FULL

SHEET METAL FLASHING

ALUMINUM SILL FLASHING

2x WOOD HEADER

ANCHOR

1/2" GYPSUM WALL BOARD

SLIDING ALUMINUM WINDOW AS SPECIFIED

WOOD SIDING ON 5/8" EXTERIOR PLYWOOD SHEATHING

ALUMINUM WINDOW FRAME CLIP

FRAME ANCHOR

WOOD FRAME SILL

HOLLOW METAL FRAME AS SCHEUDLED

SLIDING SILL @ CFMF W/ METAL PANEL

FIXED WOOD WINDOW AS SPECIFIED PROFILE WILL VARY

BATT INSULATION R=

6" OR 8" CMU BACK UP WALL

MOISTURE RETARDER SILL BELOW

CAULK- COLOR TO MATCH WALL COLOR ALUMINUM CASEMENT WINDOW AS SPECIFIED 2X BLOCKING

MASONRY OR PRECAST CONCRETE SILL CAULK-COLOR TO MATCH WALL COLOR SELECTION PROFILE MAY VARY

ALUMINUM AWNING WINDOW @ CMU W/ EIFS AWNING JAMB @ CMU W/ SILL EIFS@ WLF W/ SIDING FIXED N.T.S RIGID INSULATION R=

5/8" ABUSE-RESISTANT GYPSUM WALLBOARD ON UTILITY MASONRY 3 5/8" METAL STUDVENEER FRAMING

5/8" GWB ON 7/8" METAL FURRING

WOOD FRAME AS SPECIFIED

WOOD FRAME CASEMENT WINDOW AS SPECIFIED

1/2" EXTERIOR GRADE SHEATHING

UTILITY MASONRY VENEER

P.T., WEATHER PROOFED WOOD SILL. PROFILE WILL VARY

SEALANT B&R OR compression DEPENDING ON SPACE

AIR SPACE DRAINAGE MAT ON 1 1/2 RIGID INSULATION R=

AS SPECIFIED

6"/ 8" CONCRETE MASONRY UNIT SILL FLASHING UNDER WINDOW FIN W/ BULLNOSED EDGE LAP OVER AIR BARRIER

SHEET METAL FLASHING

UTILITY BRICK MASONRY VENEER

WOOD FRAME, BRICK SILL

ALUMINUM AWNING WINDOW UNIT AS SPECIFIED

P.T. WOOD BLOCKING

SILL BELOW

LIQUID-APPLIED AIR BARRIER

WOOD FRAME & SILL

EIFS PER SPECIFICATIONS

SHEET METAL FLASHING

SELF-ADHERED 40 MIL VAPOR/AIR BARRIER WINDOW PERIMETER WRAP

SILL BELOW

SILL ALUMINUM SILL

1/2" GYP. BOARD . FINISH AS SPECIFIED

HOLLOW METAL FRAME

FIXED WOOD WINDOW UNIT AS SPECIFIED PROFILE MAY VARY

BATT INSULATION

ALUMINUM HORIZONTAL SLIDING WINDOW AS SPECIFIED

CONT. SEALANT

GROUT FULL

INVERTED C-CHANNEL SILL PLATE WEATHER-RESISTANT WOOD SILL 2x DOUBLE SILL PLATE

WOOD SIDING ON 1/2" EXTERIOR PLYWOOD SHEATHING

ALUMINUM SILL

WOOD WINDOW STOOL W/ CASING TRIM SHIM AS REQ'D

3 5/8" CFMF STUD WALL W/ BATT INSULATION

METAL PANEL SILL & ASSOC. FRAMING LAP FLASHING AND WRB @ PANEL JOINTS

5

HM DOOR IN CFMF @ JAMB @ PARTITION

4" CONCRETE MASONRY UNITS

N.T.S

BATT OR BLOWN IN INSULATION AS SPECIFIED

1/2" GYPSUM WALL BOARD

5/8" ABUSE RESISTANT GWB

HEAD

BATT INSULATION R=

NEW 4" CONCRETE MASONRY UNITS

3

WF SINGLE HUNG WINDOW @ WLF W/ FIBER CEMENT N.T.S

CERAMIC WALL TILEsee Room Finish Schedule for Locations CONTINUOUS SEALANT (BOTH SIDES)

METAL PANEL SILL

4

SLIDING WINDOW @ CFMF W/ INSULATED METAL PANEL N.T.S

ALUMINUM HORIZONTAL SLIDING WINDOW AS SPECIFIED

GROUT FULL STEEL LINTEL - see Structural Drawings for Lintel Schedule

GROUT FULL

INVERTED C-CHANNEL SILL PLATE SHEET METAL SUB-SILL FLASHING 3 5/8" CFMF STUD WALL W/ BATT INSULATION

12

5/8" ABUSE RESISTANT GWB

CONTINUOUS SEALANT (BOTH SIDES)

METAL PANEL SILL & ASSOC. FRAMING LAP FLASHING AND WRB @ PANEL JOINTS

HOLLOW METAL FRAME

BATT OR BLOWN IN INSULATION AS SPECIFIED

GROUT FULL

ANCHOR HOLLOW METAL DOOR FRAME

cadd- standard details

NEW 6" CONCRETE MASONRY UNIT

BCK-IBI Group, Binghamton, NY

I completed significant updates to BCK’s CAD standards library by converting and drafting a large number of standard details in REVIT 2013. This sheet illustrates familiarity with drafting and CAD standards, as well as basic Construction Document layout.

6

HM DOOR IN CMU W/ GLAZED TILE @ JAMB N.T.S

7

HM DOOR FRAME ANCHORED IN CMU N.T.S


r e l l o R Full Track

’ n e Wom s Flat

Contact

Derby

: n o i t a m r o f n I e r o For M m ames.co D y rb e D ls il H g in ll o www.R gmail.com s@ e m a D y rb e D ls il H Rolling

14

sports branding

Rolling Hills Derby Dames: Marketing Coordinator

Logo line work provided by RHDD. Solely responsible for logo colorization, layouts and typography. Clockwise from above: 11x17 poster 3’ x 6’ vinyl banner 3x5 bumper sticker Web banner Die-Cut sticker 1/4 sheet fliers


16

Event Branding

Roller Derby Bout: April 6, 2012, 2000+ Attendees

Original full-color illustrations, typography & layout. Black and white logos provided by event partners Clockwise from above: 11x17 Event Poster Press Pass VIP Tickets Day-of Program & Schedule 1/4 sheet fliers


thank you. Laura.graden@gmail.com 35 rotary Ave. Binghamton, NY 13901 208.521.8442


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.