Arunda verbindingssysteem

Page 1

Create your own timber frame dovetail assemblies ! info@arunda.ch www.arunda.ch


The Arunda® System

The Advantages

Arunda® is a system for manually making dovetailed wood-to-wood joints to assemble timber frame structures.

Speed. 8 to 18 mortise/tenon joints per hour. Ease of use. Push-down dovetail assembly is very fast and easy. No need to pull apart the load-bearing beams to insert tenons.

All you need is a pair of Arunda® jigs (one for the tenon and the other for the mortise), a powerful router fitted with the special Arunda® cutter, and some accessories.

Precision. Double-cone self-tightening joints. Flexibility. Perpendicular or angled joints on floor joists or rafter (roof systems).

There are several models available but only one size will be selected to fit your most commonly used timber widths. Keep in mind: The bigger the joint, the greater and better its resistance!

Versatility. Usable on a wide range of timber widths from 60 to 300 mm (2 3/8” to 11 13/16” ), for new construction as well as for restoration work.

Timber widths and working loads tables

The jig models Class “A” with fixed fences (90°)

Timber width (mm/inches)

Class “S” with tilting fences (+50°/-50°) N° 60

min. 50 2” 60-80 mm 2 3/8” - 3 1/8”

120-180 mm 4 3/4” - 7 1/16”

N° 120

0

50

max. 200 mm 7 7/8”

100 150 200 Timber width (mm)

270-730 kg 590-1610 lbs 370-930 kg 810-2050 lbs

N° 100

max. 160 mm 6 1/4”

465-1200 kg 1020-2645 lbs

N° 120 570-1700 kg 1255-3745 lbs

N° 160 250

300

Quality. A fine all-timber roof frame assembly.

150-450 kg 330-990 lbs

N° 80

min. 140 5 1/2” 160-300 mm 6 1/4” - 11 13/16”

N° 160 Several models available, you choose just one – that best adapted to your needs!

Working loads (kg) N° 60

max. 140 mm 5 1/2”

100-140 mm 4” - 5 1/2”

N° 100

min./max.

max. 100 mm 4”

80-120 mm 3 1/8” - 4 3/4”

N° 80

optimal

Time-saving. Identical router bit setting to cut both mortise and tenon.

0

250

500 750 1000 1250 1500 1750 Working loads (kg) per joint

Comparison between assemblies using metal connectors and the Arunda® System № 60 (A/S)

№ 80 (A/S)

№ 100 (A/S)

№ 120+ (A/S)

№ 160+ (A)

Tenon on timber width: 60-80 (max. 100) mm 2 3/8” - 3 1/8” (max. 4”) Height: 90-280 mm 3 1/2” - 11” Section: min. 50x90 mm max. 100x280 mm min. 2” x 3 1/2” max. 4” x 11”

Tenon on timber width: 80-120 (max. 140) mm 3 1/8” - 4 3/4” (max. 5 1/2”) Height: 90-280 mm 3 1/2” - 11” Section: min. 80x90 mm max. 140x280 mm min. 3 1/8” x 3 1/2” max. 5 1/2” x 11”

Tenon on timber width: 100-140 (max. 160) mm 4” - 5 1/2” (max. 6 1/4”) Height: 90-280 mm 3 1/2” - 11” Section: min. 100x90 mm max. 160x280 mm min. 4” x 3 1/2” max. 6 1/4” x 11”

Tenon on timber width: 120-180 (max. 200) mm 4 3/4” - 7 1/16” (max. 7 7/8”) Height: 90-330 mm 3 1/2” - 13” Section: min. 120x90 mm max. 200x330 mm min. 4 3/4” x 3 1/2” max. 7 7/8” x 13”

Tenon on timber width: 160-300 mm 6 1/4” - 11 13/16” Height: 90-420 mm 3 1/2” - 16 1/2” Section: min. 140x90 mm max. 300x420 mm min. 5 1/2” x 3 1/2” max. 11 13/16” x 16 1/2”

Metal connector ✓ ✓ ✓ 5 to 8 units/hour CHF 10.- to 16.Cost of metal connector (ATF Type) CHF 19.- to 33.Cost of metal connector screws (between 16 and 46 screws according to model) CHF 1.- to 3.Total cost per joint (excluding write-off of material and machines) CHF 30.- to 50.Speed + Ease of assembly: Scale from 1 (bad) to 10 (excellent) 6-7 Milling the joist Milling the rafter Positioning the metal connector (by measuring or using the guide) Screwing (16 to 46 screws) Number of joints per hour

Arunda® ✓ ✓ 8 to 18 units/hour CHF 5.- to 10.CHF 5.- to 10.9-10

Strength. Workloads of up to 1700 kg / 3745 lbs per joint. Mobility. Just as easy to use in the workshop as on the job site. Economy. A low-cost replacement for metal connectors. You buy Arunda only once.


The Arunda® System

The Advantages

Arunda® is a system for manually making dovetailed wood-to-wood joints to assemble timber frame structures.

Speed. 8 to 18 mortise/tenon joints per hour. Ease of use. Push-down dovetail assembly is very fast and easy. No need to pull apart the load-bearing beams to insert tenons.

All you need is a pair of Arunda® jigs (one for the tenon and the other for the mortise), a powerful router fitted with the special Arunda® cutter, and some accessories.

Precision. Double-cone self-tightening joints. Flexibility. Perpendicular or angled joints on floor joists or rafter (roof systems).

There are several models available but only one size will be selected to fit your most commonly used timber widths. Keep in mind: The bigger the joint, the greater and better its resistance!

Versatility. Usable on a wide range of timber widths from 60 to 300 mm (2 3/8” to 11 13/16” ), for new construction as well as for restoration work.

Timber widths and working loads tables

The jig models Class “A” with fixed fences (90°)

Timber width (mm/inches)

Class “S” with tilting fences (+50°/-50°) N° 60

min. 50 2” 60-80 mm 2 3/8” - 3 1/8”

120-180 mm 4 3/4” - 7 1/16”

N° 120

0

50

max. 200 mm 7 7/8”

100 150 200 Timber width (mm)

270-730 kg 590-1610 lbs 370-930 kg 810-2050 lbs

N° 100

max. 160 mm 6 1/4”

465-1200 kg 1020-2645 lbs

N° 120 570-1700 kg 1255-3745 lbs

N° 160 250

300

Quality. A fine all-timber roof frame assembly.

150-450 kg 330-990 lbs

N° 80

min. 140 5 1/2” 160-300 mm 6 1/4” - 11 13/16”

N° 160 Several models available, you choose just one – that best adapted to your needs!

Working loads (kg) N° 60

max. 140 mm 5 1/2”

100-140 mm 4” - 5 1/2”

N° 100

min./max.

max. 100 mm 4”

80-120 mm 3 1/8” - 4 3/4”

N° 80

optimal

Time-saving. Identical router bit setting to cut both mortise and tenon.

0

250

500 750 1000 1250 1500 1750 Working loads (kg) per joint

Comparison between assemblies using metal connectors and the Arunda® System № 60 (A/S)

№ 80 (A/S)

№ 100 (A/S)

№ 120+ (A/S)

№ 160+ (A)

Tenon on timber width: 60-80 (max. 100) mm 2 3/8” - 3 1/8” (max. 4”) Height: 90-280 mm 3 1/2” - 11” Section: min. 50x90 mm max. 100x280 mm min. 2” x 3 1/2” max. 4” x 11”

Tenon on timber width: 80-120 (max. 140) mm 3 1/8” - 4 3/4” (max. 5 1/2”) Height: 90-280 mm 3 1/2” - 11” Section: min. 80x90 mm max. 140x280 mm min. 3 1/8” x 3 1/2” max. 5 1/2” x 11”

Tenon on timber width: 100-140 (max. 160) mm 4” - 5 1/2” (max. 6 1/4”) Height: 90-280 mm 3 1/2” - 11” Section: min. 100x90 mm max. 160x280 mm min. 4” x 3 1/2” max. 6 1/4” x 11”

Tenon on timber width: 120-180 (max. 200) mm 4 3/4” - 7 1/16” (max. 7 7/8”) Height: 90-330 mm 3 1/2” - 13” Section: min. 120x90 mm max. 200x330 mm min. 4 3/4” x 3 1/2” max. 7 7/8” x 13”

Tenon on timber width: 160-300 mm 6 1/4” - 11 13/16” Height: 90-420 mm 3 1/2” - 16 1/2” Section: min. 140x90 mm max. 300x420 mm min. 5 1/2” x 3 1/2” max. 11 13/16” x 16 1/2”

Metal connector ✓ ✓ ✓ 5 to 8 units/hour CHF 10.- to 16.Cost of metal connector (ATF Type) CHF 19.- to 33.Cost of metal connector screws (between 16 and 46 screws according to model) CHF 1.- to 3.Total cost per joint (excluding write-off of material and machines) CHF 30.- to 50.Speed + Ease of assembly: Scale from 1 (bad) to 10 (excellent) 6-7 Milling the joist Milling the rafter Positioning the metal connector (by measuring or using the guide) Screwing (16 to 46 screws) Number of joints per hour

Arunda® ✓ ✓ 8 to 18 units/hour CHF 5.- to 10.CHF 5.- to 10.9-10

Strength. Workloads of up to 1700 kg / 3745 lbs per joint. Mobility. Just as easy to use in the workshop as on the job site. Economy. A low-cost replacement for metal connectors. You buy Arunda only once.


Create your own timber frame dovetail assemblies ! info@arunda.ch www.arunda.ch


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.