EUinstruments, syringe filters

Page 1

Cellulose Acetate Syringe Filters Filter syringe with a regenerated cellulose membrane, hydrophilic material with an excellent perfomance filtering organic solvents, including also filtering acetonitrile. Usually used for clarifying and sterilizing HPLC samples.

can besterilized byautoclaving.

Three different diameters available to take in account depending the sample volume to filter: diameters 4, 15 and 25 mm, non-sterile presentation despite

The available pore sizes are 0.20, 0.45, 0.80, 1.20 and 5.00 µm.

Alsoavailable in pore sizes of 0,20 and 0,45 µm,

Technical Especifications Pore size µm 0,20 0,45 0,80 1,20 5,00 Code 16534 16534K 16555 16555K 16592 16592K 17593 17593K 17594 17594K Presentation units/box 100, 500 50 100, 500 50 100, 500 50 100, 500 50 100, 500 50 Type Non sterileSterile Non sterile Sterile Non sterile Sterile Non sterile Sterile Non sterile Sterile Membrane Cellulose acetate Cellulose acetate Cellulose acetate Cellulose acetate Cellulose acetate Housing Cyrolite Cyrolite Cyrolite Cyrolite Cyrolite Diameter mm 25 25 25 25 25 5,3 5,3 5,3 5,3 5,3 Filtration area cm2 Hold-up volume ml 0,1 0,1 0,1 0,1 0,1 Bubble point hPa 32 16 8 7 4 Max. Pressure hPa 45 45 45 45 45 Break pressure hPa 60 60 60 60 60 Max. Temperature °C 50 50 50 50 50 Flow (water, Δp 1 bar) ml/min 60 180 300 400 500 Inlet Luer lock Luer lock Luer lock Luer lock Luer lock Outlet Luer lock Luer lock Luer lock Luer lock Luer lock Hydrophylic

Yes

Yes

Yes

Applications Sterilized aqueous samples Biological samples Protein samples To determine the sitting up index inwine samples Celular culture media filtering Alimentary samples clarification Serum samples filtration

Yes

Yes

Ordering Information CODE

TYPE

SIZE mm Ø

PORE µm

PRESENTATION units/box

16534-100

Non sterile

25

0.20

100

16534 Q

Non sterile

25

0.20

500

16555-100

Non sterile

25

0.45

100

16555 Q

Non sterile

25

0.45

500

16592-100

Non sterile

25

0.80

100

16592 Q

Non sterile

25

0.80

500

17593-100

Non sterile

25

1.20

100

17593 Q

Non sterile

25

1.20

500

17594-100

Non sterile

25

5.00

100

17594 Q

Non sterile

25

5.00

500

16534 K

Sterile

25

0.20

50

16555 K

Sterile

25

0.45

50

16592 K

Sterile

25

0.80

50

17593 K

Sterile

25

1.20

50

17594 K

Sterile

25

5.00

50


Glass Fiber Syringe Filters Asyringe filter fitted with aglass microfibre pre-filter retaining 0,7 µm. These filters are very useful clarifying tubid samples with heavy charges which could drive tothe premature filter silting up. Using them together with 0,45 or 0,20 µm syringe filters can be use as a pre-filter. Are available in 0,45 or 0,20 µm membrane, inthe same housing. Presentation are 100 or 500 units box.

Applications Carrying out venting work with machines todetermine tobacco nicotine Prefiltration before 0,45 and 0,20 µm syringe filters To clarify samples with heavy particle charge content

Technical Especifications Retention

µm

Code Presentation

units/box

0,7

0,7 + 0,20

0,7+ 0,45

17824K 178240

17823K 178230

17829K 178290

50 500

50 500

Type Sterile

Sterile Non sterile

Sterile Non sterile

Membrane

Glass fiber

Housing

50

100 500

Sterile Non sterile

Glass fib+Cel. Acetate Glass fib+Cel. Acetate

Cyrolite

Cyrolite

Cyrolite

Diameter

mm

25

25

25

Filtration area

cm2

5,3

5,3

5,3 0,25

Hold-up volume

ml

0,25

0,25

Bubble point

hPa

5

5

5

Max. Pressure

hPa

45

45

45

Break pressure

hPa

60

60

60

°C

50

50

50

Max. Temperature

Flow (waler, ΔP 1bar) ml/min

600

600

600

Inlet

Luer lock

Luer lock

Luer lock

Outlet

Luer lock

Luer lock

Luer lock

Yes

Yes

Yes

Hydrophobic

Ordering Information CODE

TYPE

SIZE mm Ø

MEMBRANE

17824 K

Slerile

PORE PRESENTATION µm units/box

25

Glass fiber

50

17824 Q Non slerile

25

Glass fiber

500

17823 K

25 Glass fiber +Cel. Acetale

0.20

50

17823 Q Non slerile

Slerile

25 Glas fiber +Cel. Acetale

0.20

500

17829 K

25 Glass fiber +Cel. Acetale

0.45

50

25 Glas fiber +Cel. Acetale

0.45

500

Slerile

17829 Q Non slerile


Regenerated Cellulose Syringe Filters Filter syringe with a regenerated cellulose membrane, hydrophilic material with an excellent perfomance filtering organic solvents, including also filtering acetonitrile. Usually used for clarifying and sterilizing HPLC samples. Three different diameters available to take in account depending the sample volume to filter: diameters 4, 15 and 25 mm, non-sterile presentation despite can besterilized by autoclaving. Alsoavailable in pore sizes of 0,20 and 0,45 µm.

Technical Especifications Pore size

µm

Diameter

mm

0,20

Code Presentation

units/box

Type

0,45

4

15

25

4

15

25

17821K

17761

17764

17822K

17762

17765

50

100/500

100/500

50

100/500

100/500

Non sterile Non sterile Non sterile Non sterile Non sterile Non sterile

Membrane

Regenerated cellulose

Housing Filtration area

Regenerated cellulose

Polypropylene

Polypropylene

cm2

0,07

1,7

4,8

0,07

1,7

4,8

ml

0,005

0,01

0,15

0,005

0,01

0,15

Bubble point

hPa

33

33

54

22

22

34

Max. Pressure

hPa

7

6

6

7

6

6

Hold-up volume

Max. Temperature Flow (water, Δp 1 bar)

°C ml/min

121/30 min

121/30 min

1

30

55

2

65

150

Flow (metanol, Δp 1 bar) ml/min

1.5

75

110

5

150

240

Flow (hexane, Δp 1 bar) ml/min

5

140

230

10

280

430

Inlet

Luer lock

Luer lock

Outet

Luer slip

Luer slip

Hydrophylic

Yes

Yes

Applications

Yes

Yes

Yes

Yes

Ordering Information

HPLC samples

CODE

Clarification oforganic solvent samples

17821 K

Filtration of mixed samples (aqueous-organic)

17822 K

Non esterile

4

0,45

50

17761-100

Non esterile

15

0,20

100

TYPE

SIZE mm Ø

Non esterile

4

PORE PRESENTATION µm units/box 0,20

50

17761 Q

Non esterile

15

0,20

500

17762-100

Non esterile

15

0,45

100 500

17762 Q

Non esterile

15

0,45

17764-100

Non esterile

25

0,20

100

17764 Q

Non esterile

25

0,20

500

17765-100

Non esterile

25

0,45

100

17765 Q

Non esterile

25

0,45

500


Polyamide Syringe Filters Polyamide filter syringe are worldwide used for HLPC sampling. The excellent chemical characteristics, physical strength and hydrophilic nature make them to be a syringe filter generally used in laboratories. And socan be used in aqueous samples, biological fluids, organic samples, etc. Available pore sizes: 0,20 and 0,45 μm diameter 25 mm.

Technical Especifications Pore size

µm

0,20

Diameter

mm

25

25

17845

17846

Code Presentation

units/box

0,45

100/500

100/500

Type

Non sterile

Non sterile

Membrane

Polyamide

Polyamide

Polypropylene

Polypropylene

Housing Filtration area

cm2

4,8

4,8

ml

0,15

0,15

Bubble point (isopropanol)

hPa

34

20

Max. Pressure

hPa

6

6

Max. Temperature

°C

121/30 min

121/30 min

Flow (air, Δp 1 bar)

ml/min

Hold-up volume

65

110

Inlet

Luer lock

Luer lock

Outet

Luer slip

Luer slip

Yes

Yes

Hydrophylic

Applications HPLC samples Clarification oforganic solvent samples Filtration ofaqueous samples Culture media sterilization

Ordering Information CODE

TYPE

SIZE mm Ø

PORE PRESENTATION µm units/box

17845-100

Non esterile

25

0,20

100

17845 Q

Non esterile

25

0,20

500

17846-100

Non esterile

25

0,45

100

17846 Q

Non esterile

25

0,45

500


Polytetrafluorethylene Syringe Filters PTFE syringe filter main characteristic is its hydrophobic nature and make them not compatible with aqueous samples. By the other side PTFE is a material with an excellent chemical compatibility infront ofalmost all pure disolvent oraggresive samples.

And this iswhy it isrecommended forfiltering agressive nature samples orfor venting work. Are available in diameters 4, 15, and 25 mm. Pore sizes of 0,20 and 0,45 μm, non-sterile presentation but also can be sterilized by autoclaving.

Technical Especifications Pore size

µm

Diameter

mm

0,20

Code Presentation

25

17573

17575

15

17820K 17574 Non sterile

PTFE

Housing

PTEF

Polypropylene

Filtration area

Polypropylene

cm2

1,7

4,8

0,07

1,7

4,8

ml

0,01

0,1

0,001

0,01

0,1

Bubble point (isopropanol)

hPa

14

14

9

9

9

Max. Pressure

hPa

6

6

6

6

6

Hold-up volume

Max. Temperature

°C

127/30 min

Flow (air, Δp 1 bar) ml/min

0,6

127/30 min

1,7

0,1

0,9

Inlet

Luer lock

Luer lock

Outet

Luer slip

Luer slip

Yes

Yes

Hydrophylic

Ordering Information CODE

TYPE

SIZE mm Ø

PORE PRESENTATION µm units/box

HPLC pure solvent samples

17820 K

Non eslerile

4

0,45

50

Filtration of agresive solovent samples

17573-100

Non eslerile

15

0,20

100

17573 Q

Non eslerile

15

0,20

500

17574-100

Non eslerile

15

0,45

100

Sampling aerosol

17574 Q

Non eslerile

15

0,45

500

Venting air

17575-100

Non eslerile

25

0,20

100

17575 Q

Non eslerile

25

0,20

500

17576-100

Non eslerile

25

0,45

100

17576 Q

Non eslerile

25

0,45

500

Protection of vacuum pumps

25 17576

50 100/500 100/500

Non sterile

Membrane

Esterilizacion of air or gas samples

4

units/box 100/500 100/500

Type

Applications

0,45

15

3


Nylon membrane Syringe Filters Syringe filters offers a nylon membrane in a polypropylene housing. Due to their high chemical compatibility and physical strength, these syringe filters are recommended for clarifying and sterilizing HPLC samples up to 200 ml in volume. These units can be autoclaved. Product Features – Strong membranes with high thermostability – Compatible with aqueous and organic solutions (except acids and bases), including most HPLC solvents – Hydrophilic surface; does not require pre-wetting

Technical Especifications Pore size

µm

Membrane Housing

0,20

0,45

Nylon membrane

Nylon membrane

Polypropylene

Polypropylene

cm2

4,8

4,8

Hold-up volume

ml

0,15

0,15

Bubble point

bar

3,4

2,0

Filtration area

Flow rates

Typical values for water at differential pressure = 1 bar (100 kPa), 110 ml/min (0,45 μm), 65 ml/min (0,2 μm)

Limits for use

Max. recommended operating pressure 6 bar (600 kPa) Max. temperature, 21°C/30min

Inlet

Luer lock

Luer lock

Outet

Luer slip

Luer slip

Venting Syringe Filters Venting syringe filters are reusable units that contain a reinforced PTFE membrane with polypropylene gauze, in a polypropylene housing. These units are lightweight, approx. 20 grams, and easily connected to fermenters or containers and could work at higher pressure. The large filtering surface (20 cm2) makes it possible to work at high air flow rates even with a low pressure differential. The units are autoclavable at temperatures up to 121ºC (at least 20 times) or up to 134ºC.

Technical Especifications Pore size

µm

0,20

Membrane Housing Filtration area

0,45 Reinforced PTFE Polypropylene 20

cm2

Hold-up volume ml Bubble point

bar

0,5 1,4 (with isopropanol)

Inlet

Luer lock

Outet

Luer slip

Maximum pressurebar Temperature max.ºC Air flow (p 1 bar) Connectors

3 134

134

1,1 l/min (Δp 0,02 bar)

2,9 l/min (Δp 0,05 bar)

6–12 mm or 1/8" NTP

6–12 mm or 1/8" NTP


Turn static files into dynamic content formats.

Create a flipbook