TENNIS COURT LIGHTING
OUTDOOR TENNIS COURT LIGHTING
Artificial lighting to sporting facilities needs to be carefully planned in order to meet the high levels of illumination and uniformity required by each sport, as well as avoid glare and provide an energy efficient solution. Each sport has its own specific lighting requirements which are determined by the pace of play, size and speed of the ball, spectator location, and nature of the sport.
Up until recently, particularly for outdoor sporting facilities, it was only metal halide flood lights that could handle this task. The high output lamps could deliver the best luminous efficacy, whilst also provide appropriate levels of colour temperature and colour rendering for this specialist area of lighting.
Advancements in LED technology mean that it is now possible to substitute metal halide fittings for LED’s with an equivalent lumen package that consume only half of the power of their traditional counterparts. This is in addition to all of the other benefits of LED’s over HIT lamps such as reduced maintenance intervals, instantaneous operation, and colour stability.
1
With the above in mind, the following examples illustrate the advantages of contemporary LED area lighting over conventional Metal Halide when applied to Outdoor Tennis Court Lighting.
Tennis is a fast paced sport which demands high levels of visual acuity. Good contrast between the ball and the vertical surrounds are important, however the drop off in illumination levels beyond the boundary lines should not to be too stark as players are also active in those areas.
In addition to the court itself being uniformly lit, the ball should also have a consistent level of illumination for players to better judge its velocity and trajectory during play.
Luminaires should be mounted at a sufficient height in order to mitigate glare.
2
Recommended lighting levels
Based on the requirements set out in BS EN 12193:2007 and shown in the table referenced, there are three levels of classification for outdoor tennis courts:
* Table from the European Standard for Sports Lighting EN12193
Class I
Top-level national and international competitions (non-televised) with requirements for spectators with potentially long viewing distances.
Class II
Mid-level competition, such as regional or local club tournaments. This generally involves medium-sized numbers of spectators with average viewing distances. High-level training may also be included in this class.
Class III
Twin court systems
11 m 11 m Mounting Height 7.0 m 33 m
Lighting specifications for outdoor courts 7 m 7 m Mounting Height 7.0 m 33 m
33 m
11 m 11 m Mounting Height 7.0 m
3
court
Single
systems
Residential Standard 4 x Environ 1000 Standard 10 x Environ 1000 9 x Poles Deluxe 12 x Environ 1000 9 x Poles
Low-level competition, such as local or small club tournaments. This does not usually involve spectators. General training, school sportsand recreational activities also fall into this class. Horizontal illuminance Uniformity of illuminance Glare Lamp colour temperature Lamp colour rendering Eh average (lux) Emix / Eh ave GR (K) R a Class l > 500* > 0.7 < 50 > 4000 > 80 Class ll > 300* > 0.7 < 50 > 4000 > 65 Class lll > 200* > 0.6 < 55 > 2000 > 20 16.5 m
Lighting calculations
The following DIALux illuminance calculations analyse a standard metal halide flood light solution against two contemporary LED flood light options, and how they compare side by side when lighting single and twin outdoor tennis courts.
Whilst traditional (metal halide) lighting installations would require costly additional hardware in order to accommodate staged lighting between the different classes, LED flood lights are better equipped for this scenario allowing for more flexibility (professional, amateur, recreational level of play) and energy savings.
4
Six of Single 1050W HIT = 6,300W
Three of Dual 1050W HIT = 6,300W
E avg = 318 lx
Emin/Eavg = 0.38
Emin = 120 lx E max = 738 lx
MUSTANG 34
MS-93051
Six of Single 1050W HIT = 6,300W
E avg = 355 lx
Emin/Eavg = 0.40
Emin = 143 lx E max = 471 lx
Six of Single 1050W HIT = 6,300W
Three of Dual 1050W HIT = 6,300W
E avg = 318 lx
Emin/Eavg = 0.38
Emin = 120 lx E max = 738 lx
5
Metal halide solution
SINGLE COURT - Lighting level class III
TWIN COURT - Lighting level class II
TWIN COURT - Lighting level class III
Ten of Dual 275W LED = 5,500W
Nine poles total, centre pole with four heads
E avg = 300 lx
Emin/Eavg = 0.71
Emin = 214 lx E max = 494 lx
LED solution
BILLUND 3
BIU-90025
Six of Dual 275W LED = 3,300W
E avg = 318 lx
Emin/Eavg = 0.62
Emin = 197 lx E max = 396 lx
Ten of Dual 275W LED = 5,500W
Nine poles total, centre pole with four heads
E avg = 300 lx
Emin/Eavg = 0.71
Emin = 214 lx E max = 494 lx
6
SINGLE COURT - Lighting level class III
TWIN COURT - Lighting level class II
TWIN COURT - Lighting level class III
Nine of Dual 210W LED = 3,780W
E avg = 211 lx
Emin/Eavg = 0.72
Emin = 152 lx E max = 316 lx
LED solution
STEAMER 12
SE-90032
SINGLE COURT - Lighting level class III
Six of Dual 210W LED = 2,520W
E avg = 266 lx
Emin/Eavg = 0.62
Emin = 164 lx E max = 363 lx
Nine of Dual 210W LED = 3,780W
E avg = 211 lx
Emin/Eavg = 0.72
Emin = 152 lx E max = 316 lx
7
TWIN COURT - Lighting level class II
TWIN COURT - Lighting level class III
Comparing the various solutions and their respective power consumption, the energy savings that can be made by switching from Metal Halide to LED flood lights quickly become apparent.
When taking into account the additional benefits that LED lamps provide – such as longer life, colour stability, sophisticated control options, instantaneous operation, and optimised beam distribution – and thanks to the availability of high output modules, this advanced lighting technology can now be embraced by the specialist field of sports lighting.
8
LIGMAN MUSTANG 34 MS-93051 6 of 1050W HIT 6,300W LIGMAN BILLUND 3 BIU-90025 12 of 275W LED 3,300W Consumes 48% less power than HIT equivalent LIGMAN STEAMER 12 SE-90032 12 of 210W LED 2,520W Consumes 60% less power than HIT equivalent LIGMAN MUSTANG 34 MS-93051 12 of 1050W HIT 12,600W LIGMAN BILLUND 3 BIU-90025 20 of 275W LED 5,500W Consumes 56% less power than HIT equivalent LIGMAN STEAMER 12 SE-90032 18 of 210W LED 3,780W Consumes 70% less power than HIT equivalent
BILLUND Family
9
1 m 1.5 m 2 m 1.70 m 2.5 m 3 m 3.5 m 4 m 4.5 m 5 m 5.5 m 6 m 6.5 m 7 m 7.5 m 8 m
BILLUND 1 BIU-90001
BILLUND 2 BIU-90011
4 m - 6 m
BILLUND 3 BIU-90021
Innovative, high-performance, sustainable street and area lighting family. Future proof solutions offering flexible glare-controlled optic options, high efficacies, robust environmental protection and a slim attractive profile
une famille d’éclairage innovante de rues et de parkings. Performante et durable.
Solutions d’avenir offrant des options optiques souples à éblouissement contrôlé, des rendements élevés, une protection de l’environnement robuste et un profil esthétique.
Familia innovadora y sustentable, de alto rendimiento, de iluminación de calles y ambientes.
Soluciones de prueba a futuro que ofrecen opciones ópticas flexibles de deslumbramiento controlado, alta eficiencia, protección ambiental robusta y un perfil atractivo delgado
10 STREET & AREA LIGHTING LUMINAIRES
underwater inground recessed light column post top street light solar light surface ceiling pendant High bay bollard oodlight GOBO poles Solar LINE ES FR EN
- SU01 - SU02 - SU03 - SU04 - SW01 - SW02 - SW03 Concrete Softscape Stone Corten Oak Walnut Pine Urban Urban Urban Urban Woodland Woodland Woodland
colour code - 01 - 02 - 03 - 05 - 06 Black Dark Grey White Matt Silver Bronze RAL 9011 RAL 7043 RAL 9003 RAL 9006 RAL 6014
BILLUND
Special finishes upon request
Product
Luminaire structure ES
- Die-cast aluminium housing
- Pre-treated before powder coating ensuring high corrosion resistance
- Thermal heat dissipation body
- One IP68 connector supplied with 0.3 m of 3x1.0 sqmm outdoor cable
- Stainless steel fasteners in grade 304 with zinc flake coating (ZFC)
- Durable silicone rubber gasket
- High-efficiency polycarbonate lens
- High-efficiency PMMA lens
- Clear toughened glass
- Surge protection 10kV
- Constant lumen output (CLO) and Night-time dimming options
Feature symbols
- Boîtier en aluminium moulé
- Pré-traitée avant revêtement en poudre assurant une résistance élevée à la corrosion
- Corps de dissipation thermique
- Un connecteur IP68 fourni avec 0.3 m de câble extérieur 3x1.0 mm²
- Vis en acier inoxydable 304, Enduit de zinc lamellaire (ZFC)
- Joint en caoutchouc silicone durable
- Lentille en polycarbonate à haute efficacité
- Lentille en PMMA à haute efficacité
- Verre trempé transparent
- Protection contre les surtensions 10kV
- Options disponibles Luminosité constante (CLO) et Gradation nocturne
Light symbols
- Carcasa de aluminio fundido a presión
- Pretratado antes del recubrimiento en polvo que garantiza una alta resistencia a la corrosión
- Cuerpo de disipación de calor térmico
- Un conector IP68 suministrado con 0,3 m de cable para exteriores de 3x1,0 mm²
- Sujetadores de acero inoxidable grado 304, Recubierto de escamas de zinc (ZFC)
- Junta de goma de silicona duradera
- Lente de policarbonato de alta eficiencia
- Lente PMMA de alta eficiencia
- Vidrio templado transparente
- Protección contra sobretensiones 10kV
- Salida de luz constante (CLO) y opciones de atenuación nocturna
11
EN
FR
T5
T1 T2 T3 T4
Dhaka mawa bhanga expressway, Dhaka, Bangladesh
* Please refer to POLES section for different pole options.
12 STREET & AREA LIGHTING LUMINAIRES Product code guide BIU-90025-LC - T2 - 8030 - ND - SC60 - 01- A90891 Spigot CCT / CRI Optic Product colour Dimming type BILLUND Spigot SC42-48 – Dia. 42-48mm. SC60 – Dia. 60mm. SC76 – Dia. 76mm. CCT / CRI 8030 – 3000K CRI80 8040 – 4000K CRI80 Dimming type ND – On/Off DI – 1-10V DA – DALI Product colour 01 – Black 02 – Dark Grey 03 – White 05 – Matt Silver 06 – Bronze Product code Light source Power Lumen Weight Optic CCT / CRI Dimming type T1 T2 T2-A T3 T3-A T4 T5 Large BILLUND 3 BIU-90025 144 LED 275 W 33136-41464 lm 15.1 kg 138°x125° 140°x63° 153°x97° 133°x66° 146°x100° 111°x65° 92°x121° 8030 | 8040 ND | DI | DA
535 430 100 100 128 10° 10° 10° 212 110 110 Ø60-76 380 950 455 115 115 131 245 15° 15° 15° 137 865 125 125 251 15° 15° 15° BILLUND 1 & 4 BILLUND BILLUND 3 & 6 Spigot SC60 Spigot Spigot SC48 Spigot SC60 Spigot SC60 Spigot SC76 Ø78 Ø82 Ø100 260 100 100 128 10° 10° 10° 212 380 455 115 115 131 245 15° 15° 15° 137 865 125 15° 15° Spigot SC60 Spigot SC76 Spigot SC48 Spigot SC60 Ø78 Ø82 260 100 100 128 10° 10° 10° 212 380 950 455 115 115 131 245 15° 15° 15° 137 865 125 15° 15° 15° Spigot SC60 Spigot SC76 Spigot SC48 Spigot SC60 Ø78 Ø82 BILLUND 3 & 6 DALI Control System Large - LIGHTCONNECT™ BILLUND 3 BIU-90025-LC 144 LED 275 W 33136-41464 lm 15.1 kg 138°x125° 140°x63° 153°x97° 133°x66° 146°x100° 111°x65° 92°x121° 8030 | 8040 DA NEMA 7 Zhaga Book 18 (Down) Zhaga Book 18 (Up) Motion sensor - PIR - DALI - Up to 3 m Motion sensor - PIR - DALI - Up to 12 m A90891 A90991-D A90991-U A91691-L2 A91691-L7 BIU-90025-LC Accessory www.ligman.com/billund
STEAMER Family
13
STEAMER 1 SE-90002+A91060
STEAMER 2 SE-90012+A91360
4
6
1 m 1.5 m 2 m 1.70 m 2.5 m 3 m 3.5 m 4 m 4.5 m 5 m 5.5 m 6 m 6.5 m 7 m 7.5 m 8 m 8.5 m 9 m 9.5 m 10 m
STEAMER 12 SE-90032+A91560
m -
m
STEAMER
Column-mounted contemporary area lighting family. Modern and powerful high-end column range using optimum-quality area floodlights.
Famille d’éclairage urbain contemporain. Gamme de têtes de mât haut de gamme moderne et puissant utilisant des projecteurs de qualité optimale pour l’éclairage routier.
Familia contemporánea de columnas empotradas en la zona de iluminación. Moderna y potente gama de columnas de gama alta con proyectores de iluminación de área de óptima calidad.
Special finishes upon request
14 STREET & AREA LIGHTING LUMINAIRES underwater inground recessed light column post top street light solar light surface ceiling pendant High bay bollard oodlight GOBO poles Solar LINE ES FR EN
- SU01 - SU02 - SU03 - SU04 - SW01 - SW02 - SW03 Concrete Softscape Stone Corten Oak Walnut Pine Urban Urban Urban Urban Woodland Woodland Woodland
code - 01 - 02 - 03 - 05 - 06 Black Dark Grey White Matt Silver Bronze RAL 9011 RAL 7043 RAL 9003 RAL 9006 RAL 6014
Product colour
Luminaire structure ES
- Die-cast aluminium housing
- Pre-treated before powder coating ensuring high corrosion resistance
- One IP68 connector supplied with 0.5 m of 3x1.0
sqmm outdoor cable
- Stainless steel fasteners in grade 304 with zinc flake coating (ZFC)
- Durable silicone rubber gasket
- Clear toughened glass
- Surge protection 10kV
Feature symbols
- Boîtier en aluminium moulé
- Pré-traitée avant revêtement en poudre assurant une résistance élevée à la corrosion
- Un connecteur IP68 fourni avec 0.5 m de câble extérieur 3x1.0 mm²
- Vis en acier inoxydable 304, Enduit de zinc lamellaire (ZFC)
- Joint en caoutchouc silicone durable
- Verre trempé transparent
- Protection contre les surtensions 10kV
Light symbols
- Carcasa de aluminio fundido a presión
- Pretratado antes del recubrimiento en polvo que garantiza una alta resistencia a la corrosión
- Un conector IP68 suministrado con 0,5 m de cable para exteriores de 3x1,0 mm²
- Sujetadores de acero inoxidable grado 304, Recubierto de escamas de zinc (ZFC)
- Junta de goma de silicona duradera
- Vidrio templado transparente
- Protección contra sobretensiones 10kV
15
EN
FR
M T2 W T3 EW T4 ME
Bureaux Caen, Caen, France
St mary’s bus interchange, Sydney, Australia
Galeries lafayette car park in annecy (74), Annecy, France
16 STREET & AREA LIGHTING LUMINAIRES
Product code guide Product code Light source Power Lumen Weight Optic CCT / CRI Dimming type M W EW T2 T3 T4 ME Rectangular - Medium Round - Large STEAMER 12 SE-90032 4 x 24 LED 209 W 24479 - 28297 lm 16.1 kg 30° 57° 105°x115° 136°x51° 119°x86° 102°x74° 137°x58° 8030 | 8040 ND | DI | DA Round - Large - LIGHTCONNECT™ STEAMER 12 SE-90032-LC 4 x 24 LED 209 W 24479 - 28297 lm 16.1 kg 30° 57° 105°x115° 136°x51° 119°x86° 102°x74° 137°x58° 8030 | 8040 DA Single arm mount Double arm mount Single arm mount Double arm mount Single arm mount Double arm mount A91060 A91160 A91260 A91360 A91460 A91560 SE-90032 SE-90032-LC • • • • • • Single adjustable 60° Double adjustable 60° Triple arm mountType 1 Triple arm mountType 2 A91660 A91760 A92260 A92360 SE-90032 SE-90032-LC SE-90032-LC - T3 - 8040 - DI - SC60 - 01 - A90891 CCT / CRI Spigot Optic Dimming type Accessory Product colour Spigot SC60 – Dia. 60mm. CCT / CRI 8030 – 3000K CRI80 8040 – 4000K CRI80 Dimming type ND – On/Off DI – 1-10V DA – DALI Product colour 01 – Black 02 – Dark Grey 03 – White 05 – Matt Silver 06 – Bronze DALI Control System Motion sensorPIR - 0-10V - Up to 3 m Motion sensorPIR - 0-10V - Up to 6 m Motion sensorPIR - 0-10V - Up to 12 m Remote controller for the motion sensor (A90191) NEMA 7 Zhaga Book 18 (Down) Zhaga Book 18 (Up) Motion sensor - PIR - DALIUp to 3 m Motion sensor - PIR - DALIUp to 12 m A90191-L2 A90191-L3 A90191-L7 A90791 A90891 A90991-D A90991-U A91691-L2 A91691-L7 SE-90032 SE-90032-LC STEAMER ROUND 75 450 520 520 650 100 Steamer street and area MEDIUM CIRCULAR LARGE CIRCULAR 580 105 80 650 350 500 100 580 75 500 650 650 730 MEDIUM RECTANGULAR LARGE RECTANGULAR 75 450 520 520 650 100 Steamer street and area MEDIUM CIRCULAR LARGE CIRCULAR 580 105 80 650 350 500 100 580 75 500 350 650 650 105 730 80 MEDIUM RECTANGULAR LARGE RECTANGULAR ø60X89 102 www.ligman.com/steamer
STEAMER
LIGMAN Lighting Co., Ltd.
17/2 Moo 4, Monthong, Bang Nam Priao, 24150 Chachoengsao
Thailand
Tel: +66 33 026 082
Lighting Experience Center
The LANTERN Building, 2300 Rama 9 Rd, Suan Luang, Suan Luang, 10250 Bangkok Thailand
Tel: +66 2 321 8211
info@ligman.com www.ligman.com
Social
/ligmangroup
For up to date contacts, please visit: www.ligman.com
LIGMAN is continually developing and improving its products. All details presented in this catalogue are correct at the time of printings, including the online version, and are not to be regarded as a form of contract. LIGMAN reserves the right to change any specification without prior notification.
Copyright © Ligman Lighting Co., Ltd.
All rights reserved.
Publication on: 2021/4 FM-MA-16/99
Updated: 01/07/23
www.ligman.com