Lobel Solar Power System
Lobel Wind Turbine Installation Drawing
Blade
Air flow
Cover
Alternator Assembly
Hub
Yaw assembly SIKCO’s scope End user’s scope
Flange
Spare flange
‘C’ class GI/MS pipe PCC Foundation or Anchored with proper support
Lobel Solar Power System
www.lobelpower.com info@lobelpower.com
09327007854
Lobel Solar Power System
4
3 2
7
9
10
5
1
6 8
12
11
13 Convex
SN 1 2 3 4 5 6 7 8
Description Cover & Safety screw Hub cover Sunk Blade Hub Key Screw M10/ M08 Face plate Lobel Solar Power System
Concave
SN 9 10 11 12 13 14 15 16
Description Alternator Alternator body Screw M6 Slip ring Yaw main shaft Screw M12 Matching flange Connection from alternator
14
SN 17 18 19 20 21 22 23 24
Description Slip ring connection Breaking switch connection Rectifier connection Over voltage relay Charge controller Connection to Battery Inverter SEB power
www.lobelpower.com info@lobelpower.com
09327007854
Lobel Solar Power System
16 Alternator
R Y B 17 Slip ring 18 Breaking switch 19 Rectifier 20
Over voltage relay From control box +
- 21 Charge Controller
+
- +
- To DC load
To battery 22
Battery
Inverter
Output
+
P
-
N 23 To state board power 24
Lobel Solar Power System
www.lobelpower.com info@lobelpower.com 09327007854
Lobel Solar Power System
6’ /10’ 15 Spare flange
SIKCO’s scope
Ht 5 ‘/ 10’
End user’s scope
(2’/50 mm dia)
100 / 150 mm dia meter ‘C’ class GI/MS pipe 20’/30’/40’
Ht 5 ‘/ 10’ (2’/50 mm dia) PCC Foundation or Anchored with proper support
Ht 20’ Dia 4” / 6” (100 mm /150 mm )
Single pole design
Lobel Solar Power System
www.lobelpower.com info@lobelpower.com
09327007854
Lobel Solar Power System
5 ft
50 ft
Lattice Tower Design
Lobel Solar Power System info@lobelpower.com
www.lobelpower.com 09327007854