THE BEST COOLING SOLUTIONS FOR THE PLASTIC INDUSTRY
With more than 40 years experience in Plastic Process Cooling Systems, Frigel has developed the most efficient, reliable and flexible cooling systems in the industry today. Your solution is guaranteed to achieve the highest standards of efficiency due to our exclusive engineering approach employing a deep analysis of the process to be cooled and the local temperature conditions. In this way you are assured of a system that is a tailor-made cooling solution, modular and easily expandable.
Intelligent Process Cooling
ECODRY® SYSTEM – SINGLE CIRCUIT WITH MACHINE-SIDE TCU/CHILLER UNITS
Micro
Ecodry EDK - Closed-Circuit Adiabatic Fluid Cooler - Power consumption: 0.014 kWh/kW / 0.05 kWh/Ton - Clean Water, Low Maintenance, Modular and Expandable. - Simple & Inexpensive Installation with one set of non-insulated pipes.
Turbo
RCM - Single Zone RCD – Double Zone High Performance Process Chiller - LWT: 0°C to 90°C / 32°F to 195°F - Precision: ± 0.1°C / ± 0.2°F - Max. Mold Water ΔT: 1.5°C / 2°F
RBM - Single Zone RBD – Double Zone High Performance Temperature Control Unit - TCU - LWT: up to 90°C / 195°F - Precision: ± 0.1°C / ± 0.2°F - Max. Mold ΔT: 1.5°C / 2°F
Plastic Injection Moulding Ecodry System – with glycol (typical layout)
Plastic Injection and Blow Moulding Ecodry System – self-draining version - no glycol (typical layout)
ECODRY® SYSTEM – SINGLE CIRCUIT WITH MACHINE-SIDE TCU/CHILLER UNITS
ECODRY SYSTEM: - Serial interface for - Low Operating Costs - Individual process control of water communication with process machine. temperature and flow. - High energy savings with the free - Search and Storage of optimum cooling valve, available in each cooling parameters for each unit. mould. - No maintenance problems related to water quality.
- Automatic Mould Preheat. - Automatic Loading and Draining of moulds.
Extrusion Plants No need for gravitational return channels. No need for concrete tanks and/or underground pools. Specific control of temperature for each extrusion line.
RCX
Plastic Extrusion
for EXTRUSION Single-Zone High Performance Process Chiller Water Temperature: from 10 to 30 °C / from 50 to 90 °F
Ecodry System – EDK and Microgel RCX (typical layout)
RCP PET Injection High flow rate and pressure It can work with open circuit Cooling Tower.
PET preforms Injection Ecodry System – EDK and Microgel RCP (typical layout)
DOUBLE SYSTEM – TWO WATER CIRCUITS WITH CENTRAL CHILLERS AND TCU (TEMPERATURE CONTROL UNIT)
Designed to minimize energy costs and maximize productivity. The Turbogel TCU (RBM – Single Zone and RBD – Dual Zone) guarantees the best hydraulic performances to each process.
Heavy
EFX
High performances Chillers With last generation compressors (high efficiency screw, oil-free centrifugal).
Plastic Injection Moulding Double Circuit with Water Condensed Chiller EDK and Heavygel EFX (typical layout)
Plastic Injection Moulding Double Circuit with Air Condensed Chiller EDK and Heavygel HGL (typical layout)
Heavy
HGL
Heavy Duty Chiller Available also in Tropicalized version, for ambient temperature up to +52 °C.
Ask for a Free “Efficiency & Energy Savings Check-Up” of Your Cooling System! Head Quarters: Frigel Firenze SpA Via Pisana, 316 50018 Scandicci (Italy) Ph +39 (055) 722-0920 Fax +39 (055) 731-1271 E-mail: sales@frigel.it
www.frigel.com
Frigel North America Inc. 150 Prairie Lake Rd, Unit A East Dundee, IL 60118 USA Ph +1 (847) 540-0160 Fax +1 (847) 540-0161 E-mail: sales.fna@frigel.com
Frigel North Italy branch E-mail: sales.italia@frigel.it Frigel Asia-Pacific ltd. E-mail: fapsales@frigel.it