J-13 Master Bedroom (Interior Working Drawings Sample)

Page 1

1085

470 100

No.

Revision/Issue

Date

-General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

6215

3165

3735

1280

General Notes

4455 4310

Key Plan

145

Mortal

680

3850

668

Brick

Demolished

1638

1091

1650

15 3

4605

Start: 0mm Height: 2900mm

145

160 Start: 0mm Height: 2220mm

600

2257

Sheet Name.

3597

Master BR As Built & Demo.

180

1935

Sheet No.

1215

Start: 0mm Height: 1210mm

1215 790

1600

2355

3597

2257 2502

2060

854

4250

3585

285 1460

3472

3676 1110

574

1303

120

160

2395

125

ID-401 04.06.2020

A3

Project Name

1

Master BR - As Built SCALE: 1 : 50

2

Master BR - Demolished SCALE: 1 : 50

J-13 Interior Project Address

Package Code

5th Settlement Project Code

ID | J-13

Scale

As indicated


3 ID-402

985 100

160 No.

Start: 0mm Height: 2900mm

565

2840

Revision/Issue

Date

1100

720

Start: 530mm Height: 1650mm

6115

575

Start: 0mm Height: 2900mm

SCALE:

Demolished

83

4

Brick

741

100

2270

Start: 0mm Height: 2900mm

1850 Refer to Master BR Masonary S2

400 650

2900

2900

1200 110

Master BR Masonary

530

150

Sheet Name.

992

25

1250

Start: 0mm End: 2180mm

95

460

25

1165

Start: 0mm End: 900mm

854

1650

4250

2900

1280

1168

Start: 0mm Height: 750mm

650

720

100 Start: 0mm Height: 2900mm

3610

SCALE: 1 : 50

Mortal

Master BR - Masonary Detail

83

1496

Master BR - Masonary S1

1116

983 Start: 0mm Height: 2900mm With Door Opening

950

100 4222

2205 60

2

100

9825

1202

3750 2 ID-402

-General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

Key Plan

Master BR - Masonary Detail

574

750

2180

900

2900

3760

1280

General Notes

3

Master BR - Masonary S2 SCALE: 1 : 50

Sheet No.

ID-402 04.06.2020

1

Master BR - Masonary SCALE: 1 : 50

A3

Project Name

J-13 Interior Project Address

Package Code

5th Settlement Project Code

ID | J-13

Scale

As indicated


120

No.

520

2880

Start: 0mm Height: 2900mm

Revision/Issue

Date

1055 Start: 530mm Height: 1650mm

General Notes -General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

6095

3615

4455

4197

Key Plan

258

Mortal

Brick

1008

1303

2200

1476

900 280

145

2060

600 1230

574

900 1143

85

65 140

280

Start: 0mm Height: 750mm

293

Start: 0mm Height: 2900mm

83

1066

4197

83

9800

1252

Demolished

Sheet Name.

854

Master BR Mortal

1042

854 1590

150

1800

110 1200

Start: 0mm Height: 2180mm

435

4250

1165

3565

3500

Start Height: 900mm

Sheet No.

ID-403 04.06.2020

A3

Project Name

1

J-13 Interior

Master BR - Mortal

Project Address

SCALE: 1 : 50

5th Settlement Project Code

ID | J-13

Package Code

Scale

As indicated


1

2405

50

1722

CW-05

TA-03

SE-02

626

580 50

900

925

258

1671

No.

890

400

810

300

-General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

525

3188

150

300

910

1680

SE-01

1477

9800

1663

2570

425

900

957

1200 145 536

80 650

Sheet Name.

Master BR Plan & Furniture

650

CW-01

580

1280

95

1170 1090

3000

1170

1582

600

554 145

CW-02

2190

110

563

500 650

336

Marble

642

1072 782

975

3567

1050

536

1540

1075

1381

1765

600

Glass

600

2030

786

Wood-Cut

2030

3567

ID-415 2

ID-414 2

500

ID-415 1

986

636 600

ID-413 3

ID-416 1 3567

ID-412

ID-416 2 2030

1430

600

636

492

ID-413 4

265

1310

1333

1310

ID-414 1

900

1200

265

1072

650

4250

618

920

224 3100

508

500

Wood-Fin.

224

660

Mortal

1181

2873

796

796

Brick

500

CW-04 2220

224

500

2220

580

1252

Key Plan 150

668

Date

General Notes

1400

1700

700

700 150

580

Revision/Issue

2158 150

ID-411 2

4455

1

LI-02

2100

ID-410 1

1280

500

TA-02

1735

50

LI-02

1457

945

285 130

TA-01

ID-411 1 ID-409 1

180

LI-01

278

180

777

448

2900

1653

500

BD-01

278

140

ID-408

Sheet No.

ID-404

1

Master BR Plan SCALE: 1 : 50

2

Master BR Furniture Plan SCALE: 1 : 50

PL-01

04.06.2020

A3

Project Name

J-13 Interior Project Address

Package Code

5th Settlement Project Code

ID | J-13

Scale

As indicated


80 140

Revision/Issue

Date

397

-300 -280

Amplifire Speaker

-300

-280

80

50 50

550

No.

393

405

-300 -350

General Notes -General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

-300

500

50 50 80

1790 3915

250

50 50

500

777

278

80

4455

-300 -300

-350

-300

Key Plan

-280

250

1277

20

20

2150

-300 3150

2501

1026

500

500

250

50 50 80

-280

Amplifire Speaker

20

145

-500

450

300

+800 F2

-300

-450

100

300

200

224

-450 23

-450

20

488

-350

-400

2030

100

1900

-450

100

130

-500

Sheet Name.

3567

1050

-462 3500

-450

-500

470

2252

1100 1750

1050

1410 2232

20

1100

GF-Master BR Ceiling

-500

120

100

4250

1100

1050

1895

1725

20 110

Sheet No.

ID-405

20

40

-400

04.06.2020

1

Master BR - Ceiling SCALE: 1 : 50

A3

Project Name

J-13 Interior Project Address

Package Code

5th Settlement Project Code

ID | J-13

Scale

1 : 50


L

C1

A3

780

A3,C1

A3,C1

480

2340

C1 580

1055

No.

50

642

393

1700

Date

663

L A3

393

General Notes -General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

663

B1,2

B2

1115

300

B1,2

6053

1400

1115

B1 3915

Revision/Issue

+670

1778

300

50

1115

880

50

Amplifire Speaker

Key Plan X

LED Light

405 //

Pendant Fixture Spotlight Type 1

A2

A1,2,3

A1,2,3

533

Track Light

Can Downlight

3150

Amplifire Speaker

393

0

533

A1 A3

Switch (x:Lines) Chandelier

1115

50

393 //

1115

E1,2,3

Indirect LED Light 1014 1540

L

+450

Track Light

E1,2,3

680

A3

120

145

F2

235 235

20

F1

+1810

20

850

850

875

F3

L +1810

300x300 Overhead Shower

545 850

F3

Sheet Name.

GF-Master BR Lighting

20

235

545

875

825

+1500

L

80

800

L

536

235 235

+1500

E3

L

200x200 Exhaust Fan

950 // 875 //

950 //

L

800

E2

L

1136

+660

875 //

225

LED Wall Outlet at Level

+1300

360

+0

F2

L

690

L

F1,3

120

1400

20 360

F2

800

E1

580

225

225 225

Lantern Fixture

628

628

235 20

Sheet No.

ID-406

1

Master BR Lighting RC SCALE: 1 : 50

2

Master BR Lighting Plan SCALE: 1 : 50

04.06.2020

A3

Project Name

J-13 Interior Project Address

Package Code

5th Settlement Project Code

ID | J-13

Scale

1 : 50


+550

2200

+550

854

A3,C1

No.

1051

Revision/Issue

Date

+350

1985

1085

350

-General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

+850

B1,2

1300

1500

+550

+850

1280

General Notes

+550 +350

1500

952

H1,G2

+350

250

GF-Master BR Electrical Fixture

300

T +350

+350

A1,2,3

600

1320

1135

300

796

330

330

200 225

+600

+350

+600

F1,3

324

+800 F2

265

900

115 300 150

300

X

+0 +0

Switch (x:Lines) Power Socket Outlet 16 A - 220 V HV Power Socuke Outlet Telephone / Network Outlet TV Outlet On/Off Switch (Shutter)

T

Thermostat Controller

210

+350

1100

250

920

E1,2,3

T +350

900

Description Count LED Wall Outlet 7 Duplex Power Outlet 5 Power Outlet 5 Switch with Power Outlet 1 Duplex Switches with Power Outlet 2 Duplex Switches 2 Triplex Switches 2 Shutter Switch 2 Telephone / Network Outlet 1 TV Outlet 1 HV Power Socket 1 Thermostat Controller 1

Key Plan

Sheet Name.

GF-Master BR Power Sheet No.

ID-407 04.06.2020

1

Master BR Power SCALE: 1 : 50

A3

Project Name

J-13 Interior Project Address

Package Code

5th Settlement Project Code

ID | J-13

Scale

1 : 50


No.

Revision/Issue

Date

General Notes

20mm Mortal

300

1850

2900

258 797

258

1055 32

3

Key Plan

470

138 3955

ID-408

1735

750

100

8mm Wood GF-07-W-01

200

6mm Mirror

140

20mm Marble GF-07-M-01

-General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

ID-409 1

1477

+350

ID-411 1 ID-410 1 ID-411 2

18mm Wood &Fabric GF-07-F-01 200

10

18mm Wood GF-07-W-01

20mm Marble GF-07-M-01

22mm Blocking Wood

1

Master BR - Callout 1 SCALE: 1 : 25

280 300

3

6mm Mirror

Master BR Detail 0 SCALE: 1 : 5

10

50 10 30 10 100

10mm Metal

Sheet Name.

Master BR Details

Sheet No.

ID-408 04.06.2020

A3

Project Name

J-13 Interior Project Address

Package Code

5th Settlement Project Code

ID | J-13

Scale

As indicated


No.

Revision/Issue

Date

-General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

300

220

38

100

720

350

500

500

500

462

500

General Notes

Wood-Cut

Glass

Marble

850

2180

350

100

SCALE: 1 : 25

Wood-Fin.

838

860 450

Master BR - A

Mortal

2600

2900 2400 450

900

1

Brick

2800

1540

1280 2400

2300

1712

Key Plan

Sheet Name.

Master BR Elevation A Sheet No.

ID-409 04.06.2020

A3

Project Name

J-13 Interior Project Address

Package Code

5th Settlement Project Code

ID | J-13

Scale

As indicated


No.

Revision/Issue

Date

20mm Mortal 20mm Marble GF-07-M-01 18mm Wood & Fabric GF-07-F-01

450

1540

Brick

Mortal

Wood-Fin.

Wood-Cut

Glass

Marble

2200

1700

2200

950

2550

2900

2900

2687

Fabric

-General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

Key Plan

2012

850

850

150

700

350

240

General Notes

500

10mm Decoration Metal

113

8mm Wood

1

324

260

460

Master BR - C SCALE: 1 : 25

860

850 600

CW-04

100

100

278

100 200

348 300

150

TA-03

Sheet Name.

Master BR Elevation C Sheet No.

ID-410 04.06.2020

A3

Project Name

J-13 Interior Project Address

Package Code

5th Settlement Project Code

ID | J-13

Scale

As indicated


2787

10mm Groove

8 238

10mm Metal

348 100 200

100

100

18 200

Master BR - B

Revision/Issue

Date

24mm Wood GF-07-W-02 18mm Wood GF-07-W-02

General Notes -General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

Key Plan Brick

Mortal

Wood-Fin.

Wood-Cut

Glass

Marble

500

5 ID-503

500

4 ID-503

300

SCALE: 1 : 25

6 127 113

1

100 192 24 300 24 8

18mm Wood & Fabric GF-07-F-01

789

No.

2006

Fabric

2900

10mm Metal

Marble

2500

250

2687

Mirror

2014

18mm Wood GF-07-W-01

1300

1500

238

300

113 1350

22mm Blocking Wood

250

1150

Marble Limit

Gypsum Board

Sheet Name. 1580

2006

CW-05

Master BR Elevations

100

2600

2300

CW-03 Glass

Sheet No. 8mm Wood

2

320

CW-04

04.06.2020

A3

Master BR -D SCALE: 1 : 25

100

J-13 Interior 350

600

500

Project Name

350

100 192 24 300 24 8

750

ID-411

Project Address

Package Code

5th Settlement Project Code

ID | J-13

Scale

As indicated


No.

1

Revision/Issue

Date

3

2220

ID-503

ID-503

General Notes

50x50mm Wood Block

-General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

6mm Glass

224

20mm Wood

2294

796

10x10mm Metal

6mm Glass

660

24mm Wood

280

508

500

900

265

600 600

8mm Wood

18

18mm Wood

1200

Key Plan

600

1310

2045

600

ID-415

1430 2

Wood-Fin.

Wood-Cut

Glass

Marble

145

Mortal

490

554

110

95

600

3000

80

18

18

145

1540

600

1396

Brick

782

18

ID-415 1

18

ID-414 2

18 600

ID-413 3

600

ID-413 4

ID-416 1

1072

450

2873

24

ID-414 1

536

650

536

3100

2397

500

ID-416 2

650

600

18 300 18

1272

8

1090

18

1170

750

1135

18 650

1240 650

1072

Sheet Name.

883

993

8

300

Master BR Dressing & Bath.

693

Sheet No.

ID-412 04.06.2020

1

Master BR - Dressing & Bath. SCALE: 1 : 25

A3

Project Name

J-13 Interior Project Address

Package Code

5th Settlement Project Code

ID | J-13

Scale

As indicated


500

462

500

220

100

Gypsum Board

Revision/Issue

Date

1540

General Notes -General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM. 200

Key Plan

100

300

450

838

860

1092

450

2438

1280

1090

2062

No.

Dressing - A

450

SCALE: 1 : 25

100

Sheet Name.

799

2400

1876

Sheet No.

04.06.2020 732

762

20mm Wood GF-07-W-01

Master BR Dressing Details

ID-413

1110

22mm Blocking Wood

2050

928 24 18 150 18 150 18

12 150 18 150 18

61

1090

150

150

12 150

100 38

100 50

462

4

Project Name

500

J-13 Interior Project Address

Dressing - C SCALE: 1 : 25

100

100

100

100

300

3

A3

Package Code

5th Settlement Project Code

ID | J-13

Scale

1 : 25


500

225

100

500

500

450

500

6mm Glass 50x50mm Wood Block GF-07-W-01

100

500

10x10mm Metal

Revision/Issue

Date

300

1090

300

No.

18

2400

2400

2450

300

1092

300

300

2400

300

General Notes -General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

Dressing - B

500

450

100

100 38 1090

1090

150

150

100 1090

462

100 1090

500

SCALE: 1 : 25

500

1

100

100

175

Key Plan

Sheet Name.

18

2450

Master BR Dressing Details

1888 204

204

204

Sheet No.

270

ID-414

300

1092

12

150 12 150 12 150 12

600

624

04.06.2020

SCALE: 1 : 25

J-13 Interior 100

100

100

100

100

2

Dressing - D

A3

Project Name

300

12

1092

1092

18

18

300

Project Address

Package Code

5th Settlement Project Code

ID | J-13

Scale

1 : 25


No.

Revision/Issue

Date

300x300 Overhead Shower

300 100 100

300

300

650

650

450

290

100

400

400

300 200

300 100

400

400

General Notes

Key Plan

1500

Brick

Mortal

Wood-Fin.

Wood-Cut

Glass

Marble

2300

2500

2500

2300 300

2600

650

1800

300

125

20

2600

300

10

1000

500

865

20

125 750

37 5

-General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

1000

Sheet Name.

Master BR - Bath.

100

100

430

600

900

1000

100

1345

1200

1200

600

700

1050

80

20 150

350

Bath Mixer & Hand Shower

1

Master Bath. - A SCALE: 1 : 20

2

Master Bath. - B

Sheet No.

ID-415

SCALE: 1 : 20 04.06.2020

A3

Project Name

J-13 Interior Project Address

Package Code

5th Settlement Project Code

ID | J-13

Scale

As indicated


No.

Revision/Issue

Date

400

300

300

400

Gypsum Board

650

100 100

400

General Notes -General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

Brick

Mortal

Wood-Fin.

Wood-Cut

Glass

Marble

600

700

100

2600

2600

2200

2500

1200

20

300

10

1800

300

20

Key Plan

Sheet Name.

100

Master BR - Bath.

1

Master Bath. - C SCALE: 1 : 20

2

Master Bath. - D SCALE: 1 : 20

Sheet No.

ID-416 04.06.2020

A3

Project Name

J-13 Interior Project Address

Package Code

5th Settlement Project Code

ID | J-13

Scale

As indicated


24

A

750

24

300

190

2 ID-502

616

426

200 24

312

726

24

1 ID-502

B

3

-General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

Elevation B SCALE: 1 : 10

700

24

24

986

586

24

538

252

Date

General Notes

12 24

702

24

276

Key Plan

616

640

200

200 24

24

24

24

402

24

750

300

C

4

SCALE: 1 : 10 24

SCALE: 1 : 10

Elevation D

Sheet Name. 290

CW-02 Master Dressing Seating Sheet No.

ID-501

290

426

450

426

616

12

24

24

166

190

24

Plan Detail 24

1

640

04.06.2020

24

D

Revision/Issue

200

200 24

250

640

No.

2

Elevation C SCALE: 1 : 10

5

A3

Project Name

J-13 Interior

Elevation A

Project Address

SCALE: 1 : 10

5th Settlement Project Code

ID | J-13

Package Code

Scale

1 : 10


750

450

986

300

586

450

536

No.

536

986

750

300

450 750

290

336

586

300

450

640 250

Date

450

290

450

200

Revision/Issue

200

General Notes -General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

640

616

426

450

426

616

640

24

24

190

24

24

640

450

Key Plan

Sheet Name.

CW-02 Master Dressing Seating Sheet No.

ID-502 04.06.2020

1

Detail Section A SCALE: 1 : 10

2

Detail Section B SCALE: 1 : 10

A3

Project Name

J-13 Interior Project Address

Package Code

5th Settlement Project Code

ID | J-13

Scale

1 : 10


5 ID-503

10x10 Metal

6mm Glass

50x50 Wood Block GF-07-W-01

50

111

50

111

50

111

50

111

50

111

50

111

50

111

111

50

111

50

40

10

91

10 50 2020 500

20

87

50

350

111

20mm Wood GF-07-W-01

No.

350

50

Revision/Issue

Date

450

111

500

50

500

111

67

50

26 12 12

111

50

50

224

65

50

87

67 20

2220

100

50 150

50

1

50

CW-03 - Plan 1

General Notes

22

5 ID-503

20

20

SCALE: 1 : 10

2101

224

3 ID-503

22

100

2020

20

20

2245 2205

1 ID-503

-General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

1540

1540

Key Plan

25 24

61

2400

2300

SCALE: 1 : 10

2550

2830

CW-03 - Plan 2

2

20mm Wood GF-07-W-01 20

2 ID-503

10 20 750

860

600

799

20 10 20 50 10

224

124

660

6mm Glass

3

CW-03 - Plan 3 SCALE: 1 : 10

4

50 20

100

10x10 Metal

CW-03 - Section 2 SCALE: 1 : 15

Sheet Name.

CW-03 Master Partition Sheet No.

5

CW-03 - Section 1 SCALE: 1 : 15

ID-503 04.06.2020

A3

Project Name

J-13 Interior Project Address

Package Code

5th Settlement Project Code

ID | J-13

Scale

As indicated


838

576

500 4 164

352

148

2 ID-506

3 ID-506

No.

200

4 ID-506

-General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

176

176

290

300

466

2 ID-505

307

Key Plan

18

278

278

458

820

838

1 ID-505

838

24

24

24 57 176 8

24 152 8 24

200 290

Date

General Notes

18

450

3 ID-505

490

Revision/Issue

240

290

490

540

Elevation A

1

2

SCALE: 1 : 10

2 ID-506

3 ID-506

SCALE: 1 : 10

18

4 ID-506

Elevation B

CW-04 Master TV Unit

24

838

1 ID-505

Sheet No.

ID-504 04.06.2020

486

152 8 24

278

278

176 8

24

338 24 458

820

838

Sheet Name.

3 ID-505

2 ID-505

A3

Project Name

J-13 Interior Project Address

Package Code

3

Elevation C SCALE: 1 : 10

18

5th Settlement

4

Elevation D SCALE: 1 : 10

Project Code

ID | J-13

Scale

1 : 10


A

3 ID-506

2 ID-506

50

4 ID-506

540

36

186

18

1398

24

450

1 ID-506

B No.

344

D

500

8

98

18

18

540

18 18

556

1

186

6

710

230

24

676

710 2220

General Notes -General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

C

SCALE: 1 : 10

A 3 ID-506

2 ID-506

50

4 ID-506

Date

24

724

Plan Detail 1

Revision/Issue

18

2

540

18

18

186

18

8

450

1 ID-506

450

D

500

Key Plan

366

8

770

8

230

B

8 24

C

Plan Detail 2 SCALE: 1 : 10

A 3 ID-506

2 ID-506

Sheet Name.

CW-04 Master TV Unit

148

4 ID-506

18

540

700

920

24

724 450

B

Sheet No.

ID-505

352

D

920

500

576 1 ID-506

18

04.06.2020

2220

Project Name

C

3

Plan Detail 3 SCALE: 1 : 10

A3

J-13 Interior Project Address

Package Code

5th Settlement Project Code

ID | J-13

Scale

1 : 10


3 ID-506

2 ID-506

18

4 ID-506

338

3 ID-505

18

Date

-General Contractors Must Visit The Site In Order To Become Familiar With What Could Hinder Their Work In Any Way. -The Contractor Is Responsible For Checking All Dimensions Related To His Scope Before Work Commences On Site. -All Errors Or Anomalies Should Be Reported. -The Contractor Should Coordinate The Drawings With All Related Disciplines. -Architectural Drawings Should Be Revised With Interior Design Package And Landscape Package. -All Dimensions Are In MM.

500

24 152 8 24 278

24 176 8 274

2 ID-505

Revision/Issue

General Notes

10 8

458

820

1 ID-505

838

24

No.

20

Key Plan

1

Detail Section A SCALE: 1 : 10 1 ID-506

1 ID-506

18

1 ID-506

338

3 ID-505

1 ID-505

1 ID-505

820

838

176

24

3 ID-505

Sheet Name.

300

8 282

2 ID-505

300

2 ID-505

2 ID-505

CW-04 Master TV Unit Sheet No.

10

274 10 8

176

838

200

152

1 ID-505

8 24

838

24

338

3 ID-505

20

ID-506 04.06.2020

2

Detail Section B SCALE: 1 : 10

3

Detail Section C SCALE: 1 : 10

4

Detail Section D SCALE: 1 : 10

A3

Project Name

J-13 Interior Project Address

Package Code

5th Settlement Project Code

ID | J-13

Scale

1 : 10


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.