Nuheat Manual Cable Layout Assistant

Page 1

Nuheat Cable Layout Assistant - 120V THIS IS NOT A SPACING TOOL. The spacing between cable runs should be 3” throughout the entire installation. The distance shown in the tables below specifies the distance to install the cable off the walls. Ensure that the Nuheat Cable is installed in areas where heating is essential (toe-kicks, immediately in front of toilet/shower/tub). DO NOT INSTALL the Nuheat Cable more than 1” from these areas. Adjustments need to be compensated in non-essential areas such as behind the toilet or behind the door. This tool is a GENERAL GUIDELINE only.

Model No. N1C004008

N1C009012

N1C013019

N1C020022

N1C023028

N1C029036

N1C037045

N1C046049

Sq Ft Distance 4 2.2" 5 3.4" 6 4.4" 7 5.3" 8 6.0" 9 2.2" 10 3.1" 11 3.9" 12 4.6" 13 2.3" 14 3.1" 15 3.8" 16 4.5" 17 5.1" 18 5.7" 19 6.0" 20 2.8" 21 3.4" 22 4.0" 23 2.7" 24 3.3" 25 3.8" 26 4.4" 27 4.9" 28 5.4" 29 2.7" 30 3.2" 31 3.7" 32 4.2" 33 4.7" 34 5.1" 35 5.6" 36 6.0" 37 2.6" 38 3.0" 39 3.5" 40 3.9" 41 4.4" 42 4.8" 43 5.2" 44 5.6" 45 6.0" 46 2.6" 47 3.1" 48 49

3.5" 3.9"

Model No. Sq Ft Distance 50 2.5" N1C050058 51 2.9" 52 3.3" 53 3.7" 54 4.1" 55 4.5" 56 4.8" 57 5.2" 58 5.6" N1C059073 59 2.4" 60 2.8" 61 3.2" 62 3.6" 63 3.9" 64 4.3" 65 4.6" 66 5.0" 67 5.3" 68 5.6" 69 5.9" 70 6.0" 71 6.0" 72 6.0" 73 6.0" 74 2.0" N1C074088 75 2.0" 76 2.0" 77 2.2" 78 2.5" 79 2.9" 80 3.2" 81 3.5" 82 3.8" 83 4.1" 84 4.4" 85 4.7" 86 5.0" 87 5.3" 88 5.6" 91 3.0" N1C089100 92 3.3" 93 3.6" 94 3.9" 95 4.2" 96 4.5" 97 4.8" 98 5.1" 99 5.4" 100 5.7"

1689 Cliveden Ave | Delta, BC | V3M 6V5 1.800.778.WARM (9276) | www.nuheat.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.
Nuheat Manual Cable Layout Assistant by Marble Trend - Issuu