Explosion Proof Combined Detector Technical Specifications • •

• • • • • •

Features and Benefits 1. 2. 3. 4. 5.

Multifunctional and highly reliable detector Sensing chamber for exceptional dust proof ability Twin LED for 360º vision Low profile design Initiated by fire alarm point using I-9332Ex Interface

Description C-9101 Explosion-proof Combination Heat/Photoelectric Smoke Detector is a kind of combination detector consisting of smoke sensing parts and semi-conductor heat sensing parts in technological structure and circuit structure. It’s applicable to zone 1 and zone 2 of areas with explosion-proof requirement in petroleum and chemical industries. It can match with fire alarm controller, explosion-proof addressable interface box, explosion-proof detector and terminal resistor produced by GST to conduct the processing of detector signals.

• •

Operating Voltage: DC24V, range allowed: DC12V~DC24V Operating Current: Standby Current≤60μA Alarming Current≤30mA Wiring: 1 pair Alarm Confirming LED: Red Heat Sensitivity: Class I Dimension: Diameter: 100mm, Height: 42mm (excluding the base) Safety Barrier Parameters: Uo=28VDC, Io=93mA Operating Environment: Temperature: -10ºC+40 ºC Relative Humidity:≤95%, no condensation Monitoring Area: When space height is 6m to 12m, the monitoring area of a detector is 80m2 for normal protection area; When space height is less than 6m, it is 60 m2. Enclosure Protection Level: IP22 Material and Color of Enclosure: ABS, ivory white

Call Point Installation The detector should be installed complied with all local codes or NFPA 72 National Fire Alarm Code, NFPA 70 National Electrical Code, BS5839, EN54.It is installed onto a standard one gang electrical box with a mounting hole that have 6.5cm spacing.

Mounting Hole

DZ- 03 Ex

C-9101Ex

A B


Explosion Proof Combined Detector C-9101Ex Wiring and Connection

Safety Area

Hazardous Area

K1 K2

O2

I-9332 Interface

Explosion-proof Detector

Explosion-proof Detector

O1 I1

Terminal Resistor

I2

Explosion-proof Manual Call Point

Explosion-proof Detector

Sample wiring diagram above show detectors are connected with I-9333 Interface. There are four terminals with numbers on the explosion-proof orientation base, “1” is the anode input, “2” is the anode output, “3” is the power cathode, “4” is null.

Selection of compatible Control Panels Compatible with all GST Intelligent Fire Alarm Panels via I-9332Ex Explosion Proof Interface (purchased separately)

Ordering Information: Part No C-9101Ex DZ-03 I-9332

Description Explosion Proof and Intrinsically Safe Combined Smoke and Heat Detector Conventional Standard Base Interface Module

Weight/Kg

Pack Qty per Box

0.221

120

0.050 1.5Kg

360 1

MANUFACTURED IN ACCORDANCE WITH

Note: Specifications are subject to change without notice.