Sample College Physical Condition Survey
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
Physical Condition Survey
Buildings included in this report Sample College (001) - Site (00) Sample College (001) - The Bunglow (01) Sample College (001) - The Residence (02) Sample College (001) - The House (03) Sample College (001) - Main Block (04) Sample College (001) - Study Centre (05) Sample College (001) - B Hostel (06) Sample College (001) - C Hostel (07) Sample College (001) - A Hostel (08) Sample College (001) - Learning Resources Block (09) Sample College (001) - Sports Hall (10) Sample College (001) - Garage (11)
Sample College Physical Condition Survey
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
Physical Condition Survey
Index Executive Summary General Comments Survey Method Physical Condition Methodology Risk Assessment Matrix Remaining Life of Building Elements Remaining Life of M & E Elements
Sample College Physical Condition Survey
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
Physical Condition Survey
Executive Summary Oakleaf have undertaken a Physical Condition Survey of the Sample College site. The surveys undertaken within this study relate to conditions prevailing on site in November 2009. MAIN ISSUES Backlog Maintenance Works Total remedial work required for the BUILDING and M&E Elements: Building Survey M & E Survey TOTAL COST Cost per m2 (average)
£ 666,142.00 £ 223,800.00 £ 889,942.00 £ 67.00/m2
(Please note that this is based on an estimated Gross Internal Floor Area of 13,282m2) Budget for Future Maintenance Works Total remedial work likely to be required within a five year period for the BUILDING and M&E Elements: Building Survey M&E Survey TOTAL COST Cost per m2 (average)
£ 1,390,223.00 £ 308,600.00 £ 1,698,823.00 £ 127.90/m2
(Please note that this is based on an estimated Gross Internal Floor Area of 13,282m2) These figures are exclusive of Prelims, Profit, Contingency, Fees, Expenses and VAT. Please note that these costs are for backlog works only, they exclude costs relating to any proposed service or facilities developments. They are based on bringing all areas up to a sound and operational (not new) condition. Breakdown of Condition Bands The Sample College blocks surveyed fall into the following Condition Bands: Band 1 (£0 - £25/m2) Band 2 (£26 - £75/m2) Band 3 (£76 - £100/m2) Band 4 (>£100/m2)
13.3% 13.3% 00.0% 73.4%
Please note that the percentages above are based on the number of properties that fall into each band. Breakdown of Priority Grading The Sample College blocks surveyed fall into the following Priority Grading: Priority 1 Priority 2 Priority 3 Priority 4
Sample College Physical Condition Survey
22.3% 42.6% 24.2% 10.8%
£ 578,450.00 £ 1,102,816.00 £ 626,975.00 £ 280,524.00
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
Physical Condition Survey
General Comments Sample College is located to the west of Sample and is located just outside the city centre. Oakleaf identified 15 blocks onsite with the majority being constructed in the mid part of the 1960’s. Of the 15 blocks identified there are 6 educational blocks, 5 residential blocks, a sports hall, 1 garage and 2 blocks are derelict. General Structure 11 – Garage: The building has existed beyond its life expectancy with complete replacement required. The cost allows for the removal of the existing structure and a temporary building of a similar size to be installed. 14 – Derelict Block: This block has been part demolished due to adjacent building works, with structural survey required. 15 – Derelict Block: This block has been part demolished due to adjacent building works, with structural survey required. External Fabric 02 – The Residence: There is evidence of minor cracking to the rear of the garage indicating that some movement has occurred. Remedial action includes the monitoring of the crack to observe any on-going movement. 06 – B Hostel: There is evidence that one of the zinc cladding sheets located above the windows has slipped with remedial work required. 08 – A Hostel: There is evidence of significant cracking to the brickwork on elevation 3 with remedial works to include making good and monitoring for further crack expansion. It is also noted that, like block 6, a number of the zinc cladding panels located above the windows have dismounted with their replacement required. 10 – Sports Hall: The metal sheet cladding to the block has been vandalised along the side elevation with evidence of steel reinforcing rods protruding from the cladding, costs allow for removal and making good. Windows & Doors 01 – The Bungalow: The crittal steel single glazed windows and door to the block are considered to be in poor condition along with having poor insulating qualities. Their complete replacement is therefore required. 02 – The Residence: The crittal steel single glazed windows and door to the block are considered to be in poor condition along with having poor insulating qualities. Their complete replacement is therefore required. 03 – The House: The crittal steel single glazed windows to the block are considered to be in poor condition along with having poor insulating qualities; their complete replacement is therefore required. The steel garage door is also considered to be coming to the end of its life and requiring replacement. 04 – Teaching Block: The crittal steel single glazed windows to the block are considered to be in poor condition along with having poor insulating qualities; their complete replacement is therefore required. There are also a number of softwood timber single glazed windows that are in varying condition with either making good and redecoration required or replacement. There has been some window replacement to the block with aluminium and PVCU framed double glazed windows
Sample College
Physical Condition Survey
January 2010 Project 0000
Issued by Oakleaf Surveying Ltd - 0845 293 7571
Physical Condition Survey some window replacement to the block with aluminium and PVCU framed double glazed windows being installed and these are considered to be in reasonable condition. The doors to the block are predominately of softwood timber construction and considered to be in reasonable condition with only decorative works required within the maintenance period, however the automatic aluminium doors to the main entrance are considered to be dated and require replacement within the maintenance period. 05 – Study Centre: The aluminium double glazed windows to the block are considered to be coming to the end of their expected life and complete replacement is therefore required. The doors to the block are of aluminium and timber construction and considered to be in reasonable condition with only decorative works to the timber doors required within the maintenance period. 06 – B Hostel: The crittal steel single glazed windows to the block are considered to be in poor condition along with having poor insulating qualities; their complete replacement is therefore required. There are also a number of softwood timber single glazed windows that are in poor condition and require replacement. There has been some window replacement to the block with aluminium framed double glazed windows being installed and these are considered to be in reasonable condition. The doors to the block are predominately of softwood timber construction and considered to be in reasonable condition, however there is a steel door that requires replacement due to its age and condition. 07 – C Hostel: The crittal steel single glazed windows to the block are considered to be in poor condition along with having poor insulating qualities; their complete replacement is therefore required. There are also a number of softwood timber single glazed windows that are in poor condition and require replacement. There has been some window replacement to the block with PVCU framed double glazed windows being installed and these are considered to be in reasonable condition. The doors to the block are predominately of softwood timber construction and considered to be in reasonable condition, however there is a steel door that requires replacement due to its age and condition. 08 – A Hostel: The crittal steel single glazed windows to the block are considered to be in poor condition along with having poor insulating qualities; their complete replacement is therefore required. There are also a number of softwood timber and aluminium single glazed windows that are in poor condition and require replacement. There has been some window replacement to the block with aluminium and PVCU framed double glazed windows being installed and these are considered to be in reasonable condition despite the seals to one of the windows failing. The doors to the block are predominately of softwood timber construction and considered to be in reasonable condition, however there is a steel door that requires replacement due to its age and condition. 09 – Learning Resources Block: The windows to the block are of aluminium framed single glazed construction and considered to be coming to the end of their expected life with complete replacement required. The doors to the block are of aluminium and timber construction with the original aluminium doors all requiring replacement due to their age and condition and the timber doors all requiring redecoration works within the maintenance period. 12 – Link Corridor: The corridor is lined with full height aluminium framed single glazed windows which are considered to be coming to the end of their expected life with complete replacement Sample College Physical Condition Survey
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
Physical Condition Survey which are considered to be coming to the end of their expected life with complete replacement required within the maintenance period. Roofs N.B. It was noted that the vast majority of gutters, downpipes and drainage outlets are suffering from a build up of debris with a regular clearing programme recommended to be implemented. Pitched Roofs 01 – The Bungalow: The Bungalow has one pitched concrete tile roof that is considered to be in reasonable condition however the mineral felt flashing is showing signs of deterioration with replacement required. 02 – The Residence: The Residence has one pitched concrete tile roof that is considered to be in reasonable condition however the mineral felt flashing is showing signs of deterioration with replacement required. 03 – The House: The House has one pitched concrete tile roof that is considered to be in reasonable condition however the mineral felt flashing is showing signs of deterioration with replacement required.
Sample College Physical Condition Survey
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
Physical Condition Survey
Survey Method Oakleaf have developed specific data capture pro-forma’s to cover each aspect of the regulations for each type of survey. This approach enables us to not only identify which items do not meet an appropriate condition, but also those which do. We consider that this approach is thorough and also enables the client to confirm that no items have simply been missed. Client Checks on Data Capture This approach enables the client to be able to check all on site data captured to see first hand that all items are covered and that nothing has been missed. Survey Quality Checks It also provides a mechanism to standardise on the quality of information being collected and allows ongoing monitoring of survey staff to check for quality and standard. Hand Held Electronic Data Capture using PDA's Oakleaf have their own data capture software which we will use to ensure data consistency. This uses pre-populated 'pick lists' to ensure data integrity between all auditors.
Sample College Physical Condition Survey
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
Physical Condition Survey
Physical Condition Methodology Oakleaf have developed specific data capture pro-forma’s to cover each aspect of a Physical Condition Appraisal. Oakleaf's approach is not only to identify which items do not meet an appropriate condition, but also those which do. We consider that this approach is thorough and also enables the client to confirm that no items have simply been missed. We will also provide a written Executive Summary that lists the main findings. Aspects covered in the appraisal:Each element states Condition Category (A, B, C, CX, D or DX). Each element has been identified with a budget cost to repair it. Each element has been identified with a remaining life expectancy when it will have to be either repaired or replaced. Each element has been identified with a budget cost to upgrade it to Condition 'B'. All the above have been recorded on our standard pro-forma’s and listed in a spreadsheet and database to enable the local users to maintain and update the data base on an ongoing basis. The survey covers:a) The condition of all building and engineering components, the cost for repairs and renewals and the time scale projected over a twenty year period. b) Any enforceable requirement necessary to comply with current legislation. Each building (block) has been appraised under the following categories:BUILDING A) Physical Structure B) External Fabric C) Internal Fabric D) Roof F) External Works G) Gardens MECHANICAL H) Drainage I) Heating Systems J) Steam Systems K) Vent & Air Con L) Medical Gases M) Hot/Cold Water N) Lifts O) Main Plant (Boilers/Calorifiers) P) Main Plant (Fixed Plant) P) Lightning Protection
Sample College Physical Condition Survey
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
Physical Condition Survey ELECTRICAL R) Electrical V) Fire Alarms W) Telecoms Each element category has been sub-divided into subsidiary components for ease of identification for example structure has been sub-divided into: General Structure, Foundations, Ground Stability etc. A supplementary note and cost has been provided to support identifiable work listed under subsidiary components i.e. a roof frame may require numerous items of repair such as work to wall plates, tie rods, bracing, etc. Each subsidiary component has been graded, utilising the WIMS system viz: Condition A = Good. Performing as intended and operating efficiently. B = Satisfactory. Performing as intended but exhibiting minor deterioration. B(C) = Items currently condition B but will fall to condition C within 5 year period. C = Poor. Exhibiting major defects and/or not operating as intended. D = Bad. Life expired and/or serious risk of imminent failure. X = Added to C or D if item cannot be repaired and must be replaced. In addition a repair cost has been entered against each repair to bring the component up to a sound/operationally safe condition. An estimate of time remaining until the repair is implemented has also been allocated. Time allocation covers a five year projection. Extent of items has been measured and a descriptive note recording location within premises so that items can be located. A note describing the fault and corrective work has been provided together with its location by floor and room number. Digital Photographs We have included digital photographs of key items requiring remedial work to assist in communicating the works required.
Sample College Physical Condition Survey
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
Physical Condition Survey
Risk Assessment Matrix
Sample College Physical Condition Survey
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
Physical Condition Survey
Remaining Life of Building Elements When calculating the remaining life of elements Oakleaf use the BMI publication: Life Expectancy of Building Components. Below are building elements that have the potential to fall within the 5 year backlog maintenance plan and their respective life expectancy. Timber Pitched Roof Asphalt Flat Roof Bitumen Felt Flat Roof Slate Covering to Pitched Roof Tile Covering to Pitched Roof Softwood Windows Hardwood Windows Aluminium Windows Cast Iron Gutters PVC Gutters PVC Windows Steel Windows Vinyl Sheet Flooring Carpet Flooring Decorations Lathe and Plaster Ceiling Suspended Ceilings
85 years 35 years 20 years 75 years 65 years 35 years 50 years 45 years 50 years 30 years 35 years 50 years 10 years 10 years 7 years 60 years 25 years
Clearly these are affected by on site conditions and in many cases have deteriorated to the extent that they require replacement within the above stated periods. Conversely; if the element has reached the end of its expected life but is in good condition the stated remaining life will be greater than the above.
Sample College Physical Condition Survey
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
Physical Condition Survey
Remaining Life of M & E Elements When calculating the remaining life of elements Oakleaf use the BMI publication: Life Expectancy of Building Components. Below are building elements that have the potential to fall within the 5 year backlog maintenance plan and their respective life expectancy. Plastic Water Storage Tank GRP Water Storage Tank PVCU Water Storage Tank Copper Pipework Boiler Solid Fuel Back Boiler Major Pump Radiators Thermostatic Radiator Valves Aluminium Air-Conditioning Ductwork Steel Air-Conditioning Ductwork Air-Conditioning Heater Air-Conditioning Chiller Air-Conditioning Pump Air-Conditioning Fan Heating Program Controller/Timer Thermostat Controls Electric Lighting Circuit Electric Power Circuit Fuse Box/Consumer Unit Power Outlet Socket Light Switch Fluorescent Luminaire Fluorescent Tube Incandescent Light Bulb Wet Riser Sprinkler System Dry Riser Sprinkler System Sprinkler Head Traction Drive Passenger Lift Hydraulic Passenger Lift Industrial Scissor Lift
30 years 35 years 25 years 40 years 20 years 20 years 12 years 25 years 15 years 30 years 25 years 15 years 15 years 15 years 15 years 15 years 15 years 30 years 30 years 30 years 25 years 25 years 15 years 3 years 2 years 30 years 40 years 25 years 30 years 25 years 20 years
Clearly these are affected by on site conditions and in many cases have deteriorated to the extent that they require replacement within the above stated periods. Conversely; if the element has reached the end of its expected life but is in good condition the stated remaining life will be greater than the above.
Sample College Physical Condition Survey
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
utility subrepor
Physical Condition Survey - Backlog Summary
Site :
001 - Sample College
Block : 01 - The Bunglow Condition: Year
C Year Total
2009 Block Total :
Site :
C Building
Engineering
£9,500
£8,000
£1,500
£9,500
£8,000
£1,500
001 - Sample College
Block : 02 - The Residence Condition: Year
C Year Total
2009 Block Total :
Site :
Building
Engineering
£64,150
£64,150
£0
£64,150
£64,150
£0
001 - Sample College
Block : 03 - The House Condition: Year
C Year Total
2009 Block Total :
Site :
C Building
Engineering
£23,372
£20,472
£2,900
£23,372
£20,472
£2,900
001 - Sample College
Block : 04 - Main Block Condition: Year
C Year Total
2009 Block Total :
Site :
C Building
Engineering
£538,549
£350,649
£187,900
£538,549
£350,649
£187,900
001 - Sample College
Block : 05 - Study Centre Condition: Year
C Year Total
2009 Block Total :
Sample College Physical Condition Survey
C Building
Engineering
£9,970
£2,120
£7,850
£9,970
£2,120
£7,850
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager Site :
Physical Condition Survey - Backlog Summary
001 - Sample College
Block : 06 - B Hostel Condition: Year
C Year Total
2009 Block Total :
Site :
C Building
Engineering
£40,462
£39,362
£1,100
£40,462
£39,362
£1,100
001 - Sample College
Block : 07 - C Hostel Condition: Year
C Year Total
2009 Block Total :
Site :
C Building
Engineering
£31,550
£30,100
£1,450
£31,550
£30,100
£1,450
001 - Sample College
Block : 08 - A Hostel Condition: Year
C Year Total
2009 Block Total :
Site :
C Building
Engineering
£34,894
£33,794
£1,100
£34,894
£33,794
£1,100
001 - Sample College
Block : 09 - Learning Resources Block Condition: Year
C Year Total
2009 Block Total :
Site :
C Building
Engineering
£63,240
£51,240
£12,000
£63,240
£51,240
£12,000
001 - Sample College
Block : 10 - Sports Hall Condition: Year
C Year Total
2009 Block Total :
Sample College Physical Condition Survey
C Building
Engineering
£11,380
£3,380
£8,000
£11,380
£3,380
£8,000
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager Site :
Physical Condition Survey - Backlog Summary
001 - Sample College
Block : 11 - Garage Condition: Year
C Year Total
2009
Building
Engineering
£60,000
£60,000
£0
Block Total :
£60,000
£60,000
£0
SiteTotal :
£887,067
£663,267
£223,800
Report Total :
£887,067
£663,267
£223,800
Sample College Physical Condition Survey
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
utility subrepor
Physical Condition Survey - Budget Summary
Site :
001 - Sample College
Block : 00 - Site Budget based on year condition 'B' becomes condition 'C' or worse Year
Year Total
Engineering
2010
£800
£800
£0
2013
£45,000
£45,000
£0
£45,800
£45,800
£0
Block Total :
Site :
Building
001 - Sample College
Block : 01 - The Bunglow Budget based on year condition 'B' becomes condition 'C' or worse Year
Year Total
Engineering
2010
£1,260
£1,260
£0
2011
£2,760
£2,760
£0
2012
£1,300
£1,300
£0
2013
£400
£400
£0
£5,720
£5,720
£0
Block Total :
Site :
Building
001 - Sample College
Block : 02 - The Residence Budget based on year condition 'B' becomes condition 'C' or worse Year
Year Total
Building
Engineering
2010
£2,000
£2,000
£0
2011
£800
£800
£0
2013
£2,450
£2,450
£0
2014
£1,500
£1,500
£0
£6,750
£6,750
£0
Block Total :
Sample College Physical Condition Survey
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager Site :
Physical Condition Survey - Budget Summary
001 - Sample College
Block : 03 - The House Budget based on year condition 'B' becomes condition 'C' or worse Year
Year Total
Engineering
2010
£4,342
£4,342
£0
2011
£1,850
£1,100
£750
2012
£1,180
£1,180
£0
2013
£3,120
£3,120
£0
2014
£14,450
£1,000
£13,450
£24,942
£10,742
£14,200
Block Total :
Site :
Building
001 - Sample College
Block : 04 - Main Block Budget based on year condition 'B' becomes condition 'C' or worse Year
Year Total
Engineering
2010
£19,745
£19,745
£0
2011
£59,416
£57,016
£2,400
2012
£50,004
£18,604
£31,400
2013
£253,554
£253,554
£0
2014
£117,489
£91,439
£26,050
£500,208
£440,358
£59,850
Block Total :
Site :
Building
001 - Sample College
Block : 05 - Study Centre Budget based on year condition 'B' becomes condition 'C' or worse Year
Year Total
Building
Engineering
2010
£7,420
£7,420
£0
2011
£89,850
£52,550
£37,300
2012
£14,733
£14,733
£0
2013
£1,400
£1,400
£0
2014
£111,800
£111,800
£0
£225,203
£187,903
£37,300
Block Total :
Sample College Physical Condition Survey
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager Site :
Physical Condition Survey - Budget Summary
001 - Sample College
Block : 06 - B Hostel Budget based on year condition 'B' becomes condition 'C' or worse Year
Year Total
Engineering
2010
£53,577
£53,577
£0
2011
£45,928
£30,928
£15,000
2012
£25,404
£22,804
£2,600
2013
£14,760
£14,760
£0
2014
£2,200
£0
£2,200
£141,869
£122,069
£19,800
Block Total :
Site :
Building
001 - Sample College
Block : 07 - C Hostel Budget based on year condition 'B' becomes condition 'C' or worse Year
Year Total
Engineering
2010
£16,240
£16,240
£0
2011
£22,538
£22,538
£0
2012
£29,219
£13,719
£15,500
2013
£46,293
£46,293
£0
2014
£31,400
£0
£31,400
£145,690
£98,790
£46,900
Block Total :
Site :
Building
001 - Sample College
Block : 08 - A Hostel Budget based on year condition 'B' becomes condition 'C' or worse Year
Year Total
Building
Engineering
2010
£92,935
£92,935
£0
2011
£47,895
£22,395
£25,500
2012
£34,398
£32,998
£1,400
2013
£12,175
£11,775
£400
2014
£10,775
£2,775
£8,000
£198,178
£162,878
£35,300
Block Total :
Sample College Physical Condition Survey
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager Site :
Physical Condition Survey - Budget Summary
001 - Sample College
Block : 09 - Learning Resources Block Budget based on year condition 'B' becomes condition 'C' or worse Year
Year Total
Engineering
2010
£1,500
£1,500
2011
£63,750
£63,750
£0
2012
£3,750
£3,750
£0
£0
2013
£90,460
£10,460
£80,000
2014
£108,140
£108,140
£0
£267,600
£187,600
£80,000
Block Total :
Site :
Building
001 - Sample College
Block : 10 - Sports Hall Budget based on year condition 'B' becomes condition 'C' or worse Year
Year Total
Building
Engineering
2010
£2,150
£2,150
£0
2011
£3,545
£3,545
£0
2012
£870
£870
£0
2013
£1,743
£1,743
£0
2014
£17,455
£2,205
£15,250
Block Total :
£25,763
£10,513
£15,250
SiteTotal :
£1,587,723
£1,279,123
£308,600
£1,587,723
£1,279,123
£308,600
Report Total :
Sample College Physical Condition Survey
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
Summary of Block Appraisal Cost by Total Cost
Site
Block
GIA (m2)
Block Total Cost/m2 Band
Physical Condition 001 - Sample College
04 - Main Block
3,433
£1,038,757
302.6
4
001 - Sample College
09 - Learning Resources Block
2,600
£330,840
127.2
4
001 - Sample College
05 - Study Centre
1,263
£235,173
186.2
4
001 - Sample College
08 - A Hostel
1,507
£233,072
154.7
4
001 - Sample College
06 - B Hostel
1,299
£182,331
140.4
4
001 - Sample College
07 - C Hostel
955
£177,240
185.6
4
001 - Sample College
02 - The Residence
101
£70,900
702.0
4
001 - Sample College
11 - Garage
425
£60,000
141.2
4
001 - Sample College
03 - The House
100
£48,314
483.1
4
001 - Sample College
10 - Sports Hall
850
£37,143
43.7
2
001 - Sample College
01 - The Bunglow
100
£15,220
152.2
4
Overall Total:
Sample College Physical Condition Survey
£2,428,990
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
Physical Condition Survey - Costs Summary
Year Total
Building
Engineering
Status Backlog 2009
£887,067
£663,267
£223,800
Total
£887,067
£663,267
£223,800
VAT
£155,237
£116,072
£39,165
Fees
£133,060
£99,490
£33,570
Total
£1,175,364
£878,829
£296,535
Sample College Physical Condition Survey
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
Physical Condition Survey - Costs Summary
EstateManager Year Total
Building
Engineering
Status Budget - Based on year condition 'B' becomes condition 'C' or worse 2010
£201,969
£201,969
£0
2011
£338,332
£257,382
£80,950
2012
£160,858
£109,958
£50,900
2013
£471,355
£390,955
£80,400
2014
£415,209
£318,859
£96,350
Total
£1,587,723
£1,279,123
£308,600
VAT
£277,852
£223,847
£54,005
Fees
£238,158
£191,868
£46,290
Total
£2,103,733
£1,694,838
£408,895
Sample College Physical Condition Survey
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
Physical Condition Survey - Costs Summary
EstateManager Year Total
Building
Engineering
Overall Budget - Backlog & Budget Total
£2,474,790
£1,942,390
£532,400
VAT
£433,088
£339,918
£93,170
Fees
£371,219
£291,359
£79,860
Total
£3,279,097
£2,573,667
£705,430
Sample College Physical Condition Survey
January 2010 Project 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
Summary of Block Appraisal Cost by Priority
Site
Block
Block Total
Priority 1
%
Priority 2
%
Priority 3
%
Priority 4
%
Physical Condition 001 - Sample College
00 - Site
£45,800
001 - Sample College
01 - The Bunglow
£15,220
£7,450
48.9%
£45,000
98.3%
£3,050
20.0%
£800
1.7%
£1,820
12.0%
001 - Sample College
02 - The Residence
£70,900
£63,250
89.2%
£6,400
9.0%
£1,250
1.8%
001 - Sample College
03 - The House
£48,314
£12,850
26.6%
£16,100
33.3%
£16,790
34.8%
£2,574
5.3%
001 - Sample College
04 - Main Block
£1,038,757
£318,700
30.7%
£457,786
44.1%
£170,595
16.4%
£91,676
8.8%
001 - Sample College
05 - Study Centre
£235,173
£149,550
001 - Sample College
06 - B Hostel
£182,331
£27,800
15.2%
£69,380
63.6%
£53,305
22.7%
£32,318
13.7%
38.1%
£53,145
29.1%
£32,006
17.6%
001 - Sample College
07 - C Hostel
£177,240
£21,050
11.9%
001 - Sample College
08 - A Hostel
£233,072
£20,700
8.9%
£42,950
24.2%
£87,500
49.4%
£25,740
14.5%
£115,050
49.4%
£69,970
30.0%
£27,352
11.7%
£2,900
19.1%
001 - Sample College
09 - Learning Resources Block
£330,840
£42,700
12.9%
£79,500
24.0%
£148,580
44.9%
£60,060
18.2%
001 - Sample College
10 - Sports Hall
£37,143
£950
2.6%
£10,400
28.0%
£21,815
58.7%
£3,978
10.7%
001 - Sample College
11 - Garage
£60,000
£60,000 100.0%
£2,474,790
£575,450
Totals: Percentage:
Sample College Physical Condition Survey
23.3%
£995,166 40.2%
£625,850 25.3%
£278,324 11.2%
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Site : Sample College - 001 Block : Site - 00 Facet: 1 - Building F - Building - External Works
Location: External 01 - Roads
B(C)
£40,000
4
2
0 0
0
2013
02 - Car Parks
B
£0
6
0
0 0
0
2015
02 - Car Parks
B
£0
6
0
0 0
0
2015
02 - Car Parks
B
£0
8
0
0 0
0
2017
02 - Car Parks
B
£0
10
0
0 0
0
2019
£5,000
4
2
0 0
0
2013
03 - Paths
B(C)
Tarmac: Clean and re-surface likely to be required within the maintenance period. Concrete grass: Located to main car park. Loose stones: Located to sports hall car park. Tarmac: Located to sports hall car park.
Brick paviours: Located to main car park. Tarmac: Clean and re-surface likely to be required within the maintenance period.
G - Building - Gardens
Location: External
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Fences
B(C)
01 - Fences 01 - Fences
Block Total
Sample College Physical Condition Survey
Cost to B Rem Life Priority C L
R
Year
£800
1
4
0 0
0
2010
B
£0
6
0
0 0
0
2015
B
£0
10
0
0 0
0
2019
Notes
Remedial Action
Painted metal: Requires redecoration. Located to road edge. Timber post & rail: Low-level to path and road edge. Gate - Metal (painted): Located to courtyard between A & C Hostel.
£45,800.00
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Site : Sample College - 001 Block : The Bunglow - 01 Facet: 1 - Building A - Building - Physical Structure
Location: Whole Block 01 - General Structure 02 - Foundations 03 - Ground Stability
B B B
£0 £0 £0
40 60 60
0 0 0
0 0 0 0 0 0
0 0 0
2049 2069 2069
Brickwork: Generally sound. Generally sound. Generally sound.
04 - Windows
C
£850
0
1
0 0
0
2009
06 - Doors
C
£1,500
0
1
0 0
0
2009
06 - Doors
B
£0
8
0
0 0
0
2017
Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 1 - 1No. Steel: Need to replace - located to elevation 1 - 1No. single. PVCU: Located to elevation 1.
C
£850
0
1
0 0
0
2009
Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 2 - 1No.
C
£2,550
0
1
0 0
0
2009
£200
4
3
0 0
0
2013
Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 3 - 3No. Softwood timber: Redecorate and make good located to elevation 3 - 1No. single.
B - Building - External Fabric
Location: Elevation 01
Location: Elevation 02 04 - Windows
Location: Elevation 03 04 - Windows
06 - Doors
Sample College Physical Condition Survey
B(C)
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: Elevation 04 04 - Windows
06 - Doors
C
B(C)
£1,700
0
1
0 0
0
2009
Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 4 - 2No. Softwood timber: Redecorate and make good located to elevation 4 - 1No. single.
£200
4
3
0 0
0
2013
£0 £0 £0 £0
20 20 20 20
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2029 2029 2029 2029
Brickwork. Brickwork. Brickwork. Brickwork.
£260
2
4
0 0
0
2011
£0
20
0
0 0
0
2029
£350
2
3
0 0
0
2011
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule. Anti-slip vinyl sheet flooring: In good condition. Fixed units: Kitchen units in good condition.
Location: Whole Block 01a - Masonry - Cracking 01b - Masonry - Spalling 01c - Masonry - Pointing 01d - Masonry - Finish
B B B B
C - Building - Internal Fabric
Location: 001-01-0-001 01 - Decorations
02 - Ceiling
B(C)
B
03 - Floor
B(C)
03 - Floor
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
15
0
0 0
0
2024
£260
3
4
0 0
0
2012
£0
20
0
0 0
0
2029
Location: 001-01-0-002 01 - Decorations
02 - Ceiling Sample College Physical Condition Survey
B(C)
B
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor 08 - Fixed Units
B B
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£0 £0
6 10
0 0
0 0 0 0
0 0
2015 2019
Anti-slip vinyl sheet flooring. Sanitary fittings: In good condition.
£260
3
4
0 0
0
2012
£0
20
0
0 0
0
2029
B(C)
£350
2
3
0 0
0
2011
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
B(C)
£260
3
4
0 0
0
2012
£0
20
0
0 0
0
2029
B(C)
£350
2
3
0 0
0
2011
B(C)
£260
3
4
0 0
0
2012
£0
20
0
0 0
0
2029
£350
2
3
0 0
0
2011
Location: 001-01-0-003 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Location: 001-01-0-004 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-01-0-005 01 - Decorations
02 - Ceiling 03 - Floor
B B(C)
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-01-0-006 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
£260
3
4
0 0
0
2012
£0
20
0
0 0
0
2029
B(C)
£350
2
3
0 0
0
2011
B(C)
£260
1
4
0 0
0
2010
£0
20
0
0 0
0
2029
B(C)
£350
2
3
0 0
0
2011
C
£250
0
2
0 0
0
2009
B
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-01-0-007 01 - Decorations
02 - Ceiling 03 - Floor
05 - Condition of Internal Walls
B
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule. Plaster - make good and redecorate water damage to plaster walls. Located to rear of shower.
D - Building - Roof
Location: Roof 01 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing
B B B(C)
£0 £0 £1,000
6 8 1
0 0 2
0 0 0 0 0 0
0 0 0
2015 2017 2010
01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins
B(C)
£400
2
3
0 0
0
2011
£0 £0
40 40
0 0
0 0 0 0
0 0
2049 2049
Sample College Physical Condition Survey
B B
Concrete tiles. Mineral felt. Mineral felt: Evidence of deterioration, with replacement required within the maintenance period. Painted timber: Redecorate completely. Timber. Timber. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
01g - Attached - Guttering
C
£150
0
2
0 0
0
2009
Mineral felt lined: Require clearing. PVCU - Internal: Require clearing.
01h - Attached - Down Rainwater pipes
C
£150
0
2
0 0
0
2009
01 - Heat Emitters
C
£1,500
0
2
0 0
0
2009
01 - Heat Emitters
B
£0
17
0
0 0
0
2026
B
£0
17
0
0 0
0
2026
Aniston combination boiler in good order.
B
£0
12
0
0 0
0
2021
Extract fans in good order.
03 - Distribution Boards
B
£0
15
0
0 0
0
2024
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
Hager distribution board in good order. Surface fluorescent lights in good order. Emergency lights in good order.
Facet: 2 - Engineering I - Engineering - Heating Systems
Location: Whole Block 6No. high efficiency convectors with no low surface temperature covers throughout the building require covering or replacement. Heat emitters with low surface temperature covers in good order.
O - Engineering - Main Plant
Location: Whole Block 01 - Heating Boilers P - Engineering - Main Plant
Location: Whole Block 04 - Extract Fans R - Engineering - Electrical
Location: Whole Block
V - Engineering - Fire Alarms
Location: Whole Block Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Sounders 02 - Call Points 03 - Smoke Detectors 05 - Fire Main/Zone Panel Block Total
Sample College Physical Condition Survey
Cost to B Rem Life Priority C L
B B B B
£0 £0 £0 £0
12 12 12 10
0 0 0 0
0 0 0 0
0 0 0 0
R
Year
0 0 0 0
2021 2021 2021 2019
Notes
Remedial Action
Fire sounders in good order. Fire call points in good order. Smoke detectors in good order. Fixfire main panel in good order.
£15,220.00
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Site : Sample College - 001 Block : The Residence - 02 Facet: 1 - Building A - Building - Physical Structure
Location: Whole Block 01 - General Structure 02 - Foundations 03 - Ground Stability
B B B
£0 £0 £0
40 60 60
0 0 0
0 0 0 0 0 0
0 0 0
2049 2069 2069
Brickwork: Generally sound. Generally sound. Generally sound.
04 - Windows
C
£3,400
0
1
0 0
0
2009
06 - Doors
C
£800
0
1
0 0
0
2009
06 - Doors
C
£1,500
0
1
0 0
0
2009
Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 1 - 4No. Softwood timber: Need to replace located to elevation 1 1No. single. Steel: Need to replace located to elevation 1 - 1No. single.
C
£250
0
3
0 0
0
2009
Brickwork: Remove ivy growth located to elevation 2.
C
£500
0
1
0 0
0
2009
Brickwork: Evidence of minor cracking, with monitoring for further movement required located to rear of garage (elevation 3).
B - Building - External Fabric
Location: Elevation 01
Location: Elevation 02 01d - Masonry - Finish
Location: Elevation 03 01a - Masonry - Cracking
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
01b - Masonry - Spalling
C
£250
0
1
0 0
0
2009
Brickwork: Make good to missing bricks - located to elevation 3 - 1st floor level.
04 - Windows
C
£5,950
0
1
0 0
0
2009
B(C)
£200
4
3
0 0
0
2013
Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 3 - 7No. Softwood timber: Redecorate and make good - located to elevation 3 - 1No. single.
C
£850
0
1
0 0
0
2009
Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 4 - 1No.
B
£0
20
0
0 0
0
2029
Brickwork.
B(C)
£2,250
4
2
0 0
0
2013
Galvanised Steel garage doors: Need to replace.
C
£50,000
0
1
0 0
0
2009
Derelict, with cost allowing for complete refurbishment.
06 - Doors
Location: Elevation 04 04 - Windows
Location: Whole Block 01c - Masonry - Pointing
06 - Doors C - Building - Internal Fabric
Location: Whole Block 12 - Comments D - Building - Roof Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: Roof 01 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing
B B B(C)
£0 £0 £2,000
6 8 1
0 0 2
0 0 0 0 0 0
0 0 0
2015 2017 2010
01d - Attached - Verges/Fascias/ Soffits
B(C)
£800
2
3
0 0
0
2011
01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
B B C
£0 £0 £250
40 40 0
0 0 2
0 0 0 0 0 0
0 0 0
2049 2049 2009
01h - Attached - Down Rainwater pipes
C
£250
0
2
0 0
0
2009
£1,500
5
2
0 0
0
2014
£0 £0 £150
10 10 0
0 0 2
0 0 0 0 0 0
0 0 0
2019 2019 2009
Concrete tiles. Mineral felt. Mineral felt: Evidence of deterioration with replacement required. Close boarded timber: Redecorate and make good close boarded timber fascia/soffit. Timber. Timber. Parapet gutters with mineral felt lining: Require clearing. PVCU - Internal: Require clearing.
Location: Roof 02 02a - Flat - Covering
02b - Flat - Decking 02c - Flat - Flashing 02h - Flat - Down Rainwater pipes Block Total
Sample College Physical Condition Survey
B(C)
B B C
Mineral felt: Evidence of significant moss growth with replacement likely to be required within the maintenance period. Softwood. Lead. PVCU - Internal: Require clearing.
£70,900.00
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Site : Sample College - 001 Block : The House - 03 Facet: 1 - Building A - Building - Physical Structure
Location: Whole Block 01 - General Structure 02 - Foundations 03 - Ground Stability
B B B
£0 £0 £0
40 60 60
0 0 0
0 0 0 0 0 0
0 0 0
2049 2069 2069
Brickwork: Generally sound. Generally sound. Generally sound.
04 - Windows
C
£5,950
0
1
0 0
0
2009
06 - Doors
C
£400
0
2
0 0
0
2009
Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 1 - 7No. Softwood timber: Redecorate and make good located to elevation 1 - 2No. single.
C
£850
0
1
0 0
0
2009
Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 2 - 1No.
C
£4,250
0
1
0 0
0
2009
Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 3 - 5No.
B - Building - External Fabric
Location: Elevation 01
Location: Elevation 02 04 - Windows
Location: Elevation 03 04 - Windows
Location: Elevation 04
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Windows
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
C
£1,700
0
1
0 0
0
2009
Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 4 - 2No.
B B B B B(C)
£0 £0 £0 £0 £2,250
20 20 20 20 4
0 0 0 0 2
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
2029 2029 2029 2029 2013
£0
10
0
0 0
0
2019
Brickwork. Brickwork. Brickwork. Brickwork. Galvanised steel garage doors: Need to replace. PVCU.
Location: Whole Block 01a - Masonry - Cracking 01b - Masonry - Spalling 01c - Masonry - Pointing 01d - Masonry - Finish 06 - Doors 06 - Doors
B
C - Building - Internal Fabric
Location: 001-03-0-001 01 - Decorations
B(C)
£260
4
4
0 0
0
2013
02 - Ceiling 03 - Floor
B B(C)
£0 £350
10 4
0 3
0 0 0 0
0 0
2019 2013
B(C)
£260
4
4
0 0
0
2013
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-03-0-002 01 - Decorations
02 - Ceiling 03 - Floor
B B
£0 £0
10 10
0 0
0 0 0 0
0 0
2019 2019
05 - Condition of Internal Walls
B
£0
10
0
0 0
0
2019
08 - Fixed Units
B
£0
10
0
0 0
0
2019
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Laminate flooring: In good condition. Ceramic wall tiling: In good condition. Fixed units: Kitchen units in good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-03-0-003 01 - Decorations
C
£130
0
4
0 0
0
2009
02 - Ceiling 03 - Floor
B C
£0 £175
6 0
0 3
0 0 0 0
0 0
2015 2009
£1,250
1
2
0 0
0
2010
C
£260
0
4
0 0
0
2009
B B(C)
£0 £350
6 2
0 3
0 0 0 0
0 0
2015 2011
C
£260
0
4
0 0
0
2009
B B(C)
£0 £350
6 2
0 3
0 0 0 0
0 0
2015 2011
B(C)
£130
1
4
0 0
0
2010
£0
6
0
0 0
0
2015
08 - Fixed Units
B(C)
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Vinyl sheet flooring: Requires replacement due to age and condition. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-03-0-004 01 - Decorations
02 - Ceiling 03 - Floor
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-03-0-005 01 - Decorations
02 - Ceiling 03 - Floor
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-03-0-006 01 - Decorations
02 - Ceiling Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
03 - Floor
C
£175
0
3
0 0
0
2009
Vinyl sheet tiles: Require replacement due to age and condition. Sanitary fittings: Require replacement due to age and level of deterioration.
08 - Fixed Units
C
£5,000
0
2
0 0
0
2009
B
£0
6
0
0 0
0
2015
Cupboard fit for purpose.
01 - Decorations
C
£182
0
4
0 0
0
2009
02 - Ceiling 03 - Floor
B C
£0 £245
6 0
0 3
0 0 0 0
0 0
2015 2009
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet.
B(C)
£130
3
4
0 0
0
2012
Location: 001-03-0-007 12 - Comments
Location: 001-03-0-008
Location: 001-03-1-001 01 - Decorations
02 - Ceiling 03 - Floor
B B
£0 £0
6 6
0 0
0 0 0 0
0 0
2015 2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Laminate flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-03-1-002 01 - Decorations
B(C)
£260
1
4
0 0
0
2010
02 - Ceiling 03 - Floor
B B(C)
£0 £350
6 3
0 3
0 0 0 0
0 0
2015 2012
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-03-1-003 01 - Decorations
B(C)
£260
1
4
0 0
0
2010
02 - Ceiling 03 - Floor
B B(C)
£0 £350
6 3
0 3
0 0 0 0
0 0
2015 2012
01 - Decorations
B(C)
£260
1
4
0 0
0
2010
02 - Ceiling 03 - Floor
B B(C)
£0 £350
6 3
0 3
0 0 0 0
0 0
2015 2012
B(C)
£182
1
4
0 0
0
2010
B C
£0 £245
6 0
0 3
0 0 0 0
0 0
2015 2009
£0 £0 £2,000
6 8 1
0 0 2
0 0 0 0 0 0
0 0 0
2015 2017 2010
£0 £0
8 40
0 0
0 0 0 0
0 0
2017 2049
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-03-1-004 Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-03-1-005 01 - Decorations
02 - Ceiling 03 - Floor
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet.
D - Building - Roof
Location: Roof 01 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing
B B B(C)
01c - Attached - Flashing 01e - Attached - Rafters
B B
Sample College Physical Condition Survey
Concrete tiles. Mineral felt. Mineral felt: Evidence of deterioration with replacement required. Lead. Timber. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
01f - Attached - Purlins 01g - Attached - Guttering
B C
£0 £250
40 0
0 2
0 0 0 0
0 0
2049 2009
01h - Attached - Down Rainwater pipes
C
£250
0
2
0 0
0
2009
£1,000
5
2
0 0
0
2014
£0
10
0
0 0
0
2019
Notes
Remedial Action
Timber. Parapet gutters with mineral felt lining: Require clearing. PVCU - Internal: Require clearing.
Location: Roof 02 02a - Flat - Covering
B(C)
02b - Flat - Decking
B
02c - Flat - Flashing 02e - Flat - Verges/Fascias/ Soffits
B B(C)
£0 £400
10 2
0 3
0 0 0 0
0 0
2019 2011
02h - Flat - Down Rainwater pipes
C
£150
0
2
0 0
0
2009
Mineral felt: Evidence of significant moss growth with replacement likely to be required within the maintenance period. Softwood.
Lead. Close boarded timber: Redecorate and make good close boarded timber fascia/soffit. PVCU - Internal: Require clearing.
Facet: 2 - Engineering I - Engineering - Heating Systems
Location: Whole Block
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
C
01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£100
0
1
0 0
0
2009
Old radiant heater to be removed.
B(C)
£4,800
5
3
0 0
0
2014
12No. steel panel radiators require upgrading within the maintenance schedule.
01 - Heating Boilers
B(C)
£5,000
5
3
0 0
0
2014
02 - Pumps
B(C)
£750
2
2
0 0
0
2011
Netaheat Profile heating boiler requires upgrading within the maintenance schedule. Grundfos heating pump requires upgrading within the maintenance schedule.
03 - Calorifiers
B(C)
£1,000
5
3
0 0
0
2014
O - Engineering - Main Plant
Location: Whole Block
Pre-insulated cylinder calorifier requires upgrading within the maintenance schedule.
P - Engineering - Main Plant
Location: Whole Block
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Controls
Cost to B Rem Life Priority C L
B(C)
R
Year
Notes
Remedial Action
£300
5
3
0 0
0
2014
3 Port Honeywell control valves require upgrading within the maintenance schedule.
Incoming cable in good order. MEM distribution board in good order. 14No. tungsten lights require replacement. 2No. surface fluorescent lights in good order.
R - Engineering - Electrical
Location: Whole Block 01 - Incoming Cable 03 - Distribution Boards
B B
£0 £0
10 20
0 0
0 0 0 0
0 0
2019 2029
04 - Lighting Installation
C
£2,800
0
2
0 0
0
2009
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
V - Engineering - Fire Alarms
Location: Whole Block 03 - Smoke Detectors
B(C)
£1,350
5
3
0 0
0
2014
05 - Fire Main/Zone Panel
B(C)
£1,000
5
3
0 0
0
2014
Block Total
Sample College Physical Condition Survey
9No. smoke detectors require upgrading within the maintenance schedule. Minerva main fire panel requires upgrading within the maintenance schedule.
£48,314.00
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Site : Sample College - 001 Block : Main Block - 04 Facet: 1 - Building A - Building - Physical Structure
Location: Elevation 06 & 08 05 - External Fire Escape
B
£0
10
0
0 0
0
2019
Galvanised steel walk-way to first floor - located between elevations 6 & 8.
B B B
£0 £0 £0
40 60 60
0 0 0
0 0 0 0 0 0
0 0 0
2049 2069 2069
Brickwork: Generally sound. Generally sound. Generally sound.
Aluminium: Requires replacing due to age and condition located to elevation 1 automatic. Steel framed canopy: Requires redecoration to frame and fascias - located to elevation 1 (main entrance).
Location: Whole Block 01 - General Structure 02 - Foundations 03 - Ground Stability B - Building - External Fabric
Location: Elevation 01 06 - Doors
B(C)
£1,200
4
2
0 0
0
2013
08 - Porches
B(C)
£400
1
3
0 0
0
2010
04 - Windows
B(C)
£4,400
5
3
0 0
0
2014
06 - Doors
B(C)
£400
4
3
0 0
0
2013
Location: Elevation 02
Sample College Physical Condition Survey
Softwood timber - Single: Redecorate and make good including infill panels - located to elevation 20 - 11No. Softwood timber: Redecorate and make good - located to elevation 20 - 2No. single. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: Elevation 03 04 - Windows
B(C)
£1,500
5
3
0 0
0
2014
Softwood timber - Single: Redecorate and make good including infill panels - located to elevation 3 - 5No. Softwood timber: Redecorate and make good - located to elevation 3 - 2No. single.
06 - Doors
B(C)
£400
4
3
0 0
0
2013
£0
6
0
0 0
0
2015
£700
4
3
0 0
0
2013
£0
6
0
0 0
0
2015
B(C)
£1,000
4
3
0 0
0
2013
Softwood timber: Redecorate and make good - located to elevation 7 - 2No. double & 2No. single.
04 - Windows
C
£1,200
0
1
0 0
0
2009
04 - Windows
C
£2,400
0
1
0 0
0
2009
£500
1
3
0 0
0
2010
Steel - Single: Replace crittal steel windows with more suitable alternative - located to elevation 10 - 2No. Softwood timber - Single: Replace with new - located to elevation 10 - 3No. Softwood timber: Redecorate and make good - located to elevation 10 - 1No. single & 1No. double.
Location: Elevation 06 04 - Windows
B
06 - Doors
B(C)
06 - Doors
B
Aluminium - Double: Located to elevation 6. Softwood timber: Redecorate and make good - located to elevation 6 - 2No. single & 1No. double. Aluminium: Located to elevation 6.
Location: Elevation 07 06 - Doors
Location: Elevation 10
06 - Doors
Sample College Physical Condition Survey
B(C)
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: Elevation 11 06 - Doors
B
£0
10
0
0 0
0
2019
Steel: Located to elevation 11 1No. single. Steel framed lean-to with polycarbonate covering located to elevation 11.
08 - Porches
B
£0
8
0
0 0
0
2017
C
£24,000
0
1
0 0
0
2009
B(C)
£1,500
1
3
0 0
0
2010
C
£1,800
0
1
0 0
0
2009
Steel - Single: Replace crittal steel windows with more suitable alternative - located to elevation 13 - 3No.
02a - Cladding - Attachment
B
£0
15
0
0 0
0
2024
02b - Cladding - Cracking
B
£0
15
0
0 0
0
2024
02c - Cladding - Joints
B
£0
15
0
0 0
0
2024
02d - Cladding - Finish
B
£0
15
0
0 0
0
2024
Plastic profiled sheet cladding: Located to elevation 14. Plastic profiled sheet cladding: Located to elevation 14. Plastic profiled sheet cladding: Located to elevation 14. Plastic profiled sheet cladding: Located to elevation 14.
C
£14,400
0
1
0 0
0
2009
Location: Elevation 12 04 - Windows
06 - Doors
Steel - Single: Replace crittal steel windows with more suitable alternative - located to elevation 12 - 40No. Softwood timber: Redecorate and make good located to elevation 12 - 3No. double & 3No. single.
Location: Elevation 13 04 - Windows
Location: Elevation 14
Location: Elevation 16 04 - Windows
Sample College Physical Condition Survey
Steel - Single: Replace crittal steel windows with more suitable alternative - located to elevation 16 - 24No. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 06 - Doors
B(C)
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£400
4
3
0 0
0
2013
Softwood timber: Redecorate and make good - located to elevation 16 - 2No. single.
C
£11,400
0
1
0 0
0
2009
Steel - Single: Replace crittal steel windows with more suitable alternative - located to elevation 17 - 19No.
C
£10,800
0
1
0 0
0
2009
Steel - Single: Replace crittal steel windows with more suitable alternative - located to elevation 18 - 18No.
C
£36,600
0
1
0 0
0
2009
B(C)
£1,400
4
3
0 0
0
2013
Steel - Single: Replace crittal steel windows with more suitable alternative - located to elevation 19 - 61No. Softwood timber: Redecorate and make good - located to elevation 19 - 4No. single & 2No. double.
£0 £0 £0 £0 £0 £0 £0 £0 £0
10 20 10 20 10 20 10 20 10
0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0
2019 2029 2019 2029 2019 2029 2019 2029 2019
Location: Elevation 17 04 - Windows
Location: Elevation 18 04 - Windows
Location: Elevation 19 04 - Windows
06 - Doors
Location: Whole Block 01a - Masonry - Cracking 01a - Masonry - Cracking 01b - Masonry - Spalling 01b - Masonry - Spalling 01c - Masonry - Pointing 01c - Masonry - Pointing 01d - Masonry - Finish 01d - Masonry - Finish 04 - Windows
Sample College Physical Condition Survey
B B B B B B B B B
0 0 0 0 0 0 0 0 0
Render. Brickwork. Render. Brickwork. Render. Brickwork. Render. Brickwork. PVCU - Double.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
C - Building - Internal Fabric
Location: 001-04-0-001/2/3 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
£1,300
4
4
0 0
0
2013
Redecoration required as part of a regular maintenance schedule.
£0
20
0
0 0
0
2029
B(C)
£1,750
1
3
0 0
0
2010
Plaster ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£1,300
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
£1,750
3
3
0 0
0
2012
£0
6
0
0 0
0
2015
£104
4
4
0 0
0
2013
£0
20
0
0 0
0
2029
B
Location: 001-04-0-001a 01 - Decorations
02 - Ceiling
B
03 - Floor
B(C)
03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Parquet timber block flooring: In good condition.
Location: 001-04-0-004 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B(C)
B
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
03 - Floor
C
£140
0
3
0 0
0
2009
08 - Fixed Units
B
£0
10
0
0 0
0
2019
Notes
Remedial Action
Anti-slip vinyl sheet flooring: Requires replacement due to age and condition. Sanitary fittings: In good condition.
Location: 001-04-0-005 01 - Decorations
B(C)
£390
4
4
0 0
0
2013
02 - Ceiling 03 - Floor
B B(C)
£0 £525
6 4
0 3
0 0 0 0
0 0
2015 2013
Redecoration required as part of a regular maintenance schedule. Ceiling paper: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B
£0
6
0
0 0
0
2015
Fit for purpose.
B
£0
6
0
0 0
0
2015
Fit for purpose.
C
£390
0
4
0 0
0
2009
B B(C)
£0 £525
6 2
0 3
0 0 0 0
0 0
2015 2011
Redecoration required as part of a regular maintenance schedule. Ceiling paper: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£1,170
4
4
0 0
0
2013
Location: 001-04-0-005a 12 - Comments
Location: 001-04-0-005b 12 - Comments
Location: 001-04-0-006 01 - Decorations
02 - Ceiling 03 - Floor
Location: 001-04-0-007 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
02 - Ceiling
B(C)
£5,400
5
2
0 0
0
2014
03 - Floor
B(C)
£1,575
2
3
0 0
0
2011
B(C)
£312
4
4
0 0
0
2013
C
£312
0
2
0 0
0
2009
B(C)
£420
4
3
0 0
0
2013
B(C)
£312
4
4
0 0
0
2013
C
£312
0
2
0 0
0
2009
B(C)
£420
4
3
0 0
0
2013
B(C)
£208
4
4
0 0
0
2013
C
£100
0
3
0 0
0
2009
Notes
Remedial Action
Suspended ceiling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-008 01 - Decorations
02 - Ceiling 03 - Floor
Redecoration required as part of a regular maintenance schedule. Ceiling paper: Requires replacement. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-008a 01 - Decorations
02 - Ceiling 03 - Floor
Redecoration required as part of a regular maintenance schedule. Ceiling paper: Requires replacement. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-009 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
08 - Fixed Units
B(C)
Cost to B Rem Life Priority C L
R
Year
£280
3
3
0 0
0
2012
£0
12
0
0 0
0
2021
B(C)
£208
4
4
0 0
0
2013
C
£100
0
3
0 0
0
2009
B(C)
£280
3
3
0 0
0
2012
£0
12
0
0 0
0
2021
£208
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
B(C)
£280
3
3
0 0
0
2012
B(C)
£5,200
4
4
0 0
0
2013
£0
20
0
0 0
0
2029
B
Notes
Remedial Action
Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Fitted units in good condition.
Location: 001-04-0-010 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Fitted units in good condition.
Location: 001-04-0-011 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-012 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£7,000
5
3
0 0
0
2014
Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£1,300
4
4
0 0
0
2013
£0
20
0
0 0
0
2029
B(C)
£1,750
5
3
0 0
0
2014
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£208
4
4
0 0
0
2013
C
£200
0
2
0 0
0
2009
B(C)
£280
5
3
0 0
0
2014
B(C)
£520
4
4
0 0
0
2013
£0
20
0
0 0
0
2029
£700
5
3
0 0
0
2014
Location: 001-04-0-012a 01 - Decorations
02 - Ceiling 03 - Floor
B
Location: 001-04-0-012b 01 - Decorations
02 - Ceiling
03 - Floor
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: Make good and redecorate water ingress to plaster ceiling. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-012c 01 - Decorations
02 - Ceiling 03 - Floor
Sample College Physical Condition Survey
B B(C)
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-04-0-012e 01 - Decorations
£208
4
4
0 0
0
2013
£0
20
0
0 0
0
2029
B(C)
£280
5
3
0 0
0
2014
01 - Decorations
B(C)
£520
1
4
0 0
0
2010
02 - Ceiling
B(C)
£2,400
4
2
0 0
0
2013
03 - Floor
B(C)
£700
1
3
0 0
0
2010
01 - Decorations
C
£520
0
4
0 0
0
2009
02 - Ceiling
B
£0
20
0
0 0
0
2029
£700
3
3
0 0
0
2012
£0
10
0
0 0
0
2019
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-013 Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-014
03 - Floor
08 - Fixed Units
B(C)
B
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Kitchen units in good condition.
Location: 001-04-0-014a
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
B(C)
Cost to B Rem Life Priority C L
R
Year
£208
3
4
0 0
0
2012
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£208
3
4
0 0
0
2012
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-04-0-014b 01 - Decorations
B(C)
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£104
5
4
0 0
0
2014
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-04-0-014c 01 - Decorations
B(C)
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
8
0
0 0
0
2017
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition.
Location: 001-04-0-015 01 - Decorations
B(C)
£390
1
4
0 0
0
2010
02 - Ceiling
B(C)
£1,800
4
2
0 0
0
2013
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£525
2
3
0 0
0
2011
Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
01 - Decorations
B(C)
£1,040
1
4
0 0
0
2010
02 - Ceiling
B(C)
£4,800
4
2
0 0
0
2013
03 - Floor
B(C)
£1,400
2
3
0 0
0
2011
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Vinyl sheet: Requires replacement within the maintenance schedule due to age and condition.
01 - Decorations
B(C)
£208
3
4
0 0
0
2012
02 - Ceiling
B(C)
£960
4
2
0 0
0
2013
03 - Floor
B(C)
£280
2
3
0 0
0
2011
01 - Decorations
C
£312
0
4
0 0
0
2009
02 - Ceiling
C
£1,440
0
2
0 0
0
2009
Location: 001-04-0-016
Location: 001-04-0-017 Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-017b
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£420
1
3
0 0
0
2010
Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£312
3
4
0 0
0
2012
£1,440
0
2
0 0
0
2009
B(C)
£420
1
3
0 0
0
2010
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£910
1
4
0 0
0
2010
C
£4,200
0
2
0 0
0
2009
B(C)
£1,225
4
3
0 0
0
2013
01 - Decorations
C
£1,040
0
4
0 0
0
2009
02 - Ceiling
C
£4,800
0
2
0 0
0
2009
Location: 001-04-0-017c 01 - Decorations
02 - Ceiling
03 - Floor
C
Location: 001-04-0-018 01 - Decorations
02 - Ceiling
03 - Floor
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-019
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£1,400
2
3
0 0
0
2011
Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
01 - Decorations
B(C)
£1,040
2
4
0 0
0
2011
02 - Ceiling
B(C)
£4,800
4
2
0 0
0
2013
03 - Floor
B(C)
£1,400
2
3
0 0
0
2011
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Vinyl sheet: Requires replacement within the maintenance schedule due to age and condition.
B(C)
£1,040
2
4
0 0
0
2011
£150
0
3
0 0
0
2009
B(C)
£1,400
4
3
0 0
0
2013
B(C)
£208
3
4
0 0
0
2012
Location: 001-04-0-020
Location: 001-04-0-021 01 - Decorations
02 - Ceiling 03 - Floor
C
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-022a 01 - Decorations
02 - Ceiling
B
£0
8
0
0 0
0
2017
03 - Floor
B
£0
8
0
0 0
0
2017
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition.
Location: 001-04-0-022b Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
Cost to B Rem Life Priority C L
R
Year
B(C)
£78
3
4
0 0
0
2012
02 - Ceiling
B
£0
8
0
0 0
0
2017
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
10
0
0 0
0
2019
B(C)
£78
3
4
0 0
0
2012
02 - Ceiling
B
£0
8
0
0 0
0
2017
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
10
0
0 0
0
2019
B(C)
£78
3
4
0 0
0
2012
02 - Ceiling
B
£0
8
0
0 0
0
2017
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
10
0
0 0
0
2019
B(C)
£78
3
4
0 0
0
2012
B
£0
8
0
0 0
0
2017
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-04-0-022c 01 - Decorations
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-04-0-022d 01 - Decorations
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-04-0-022e 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£910
4
4
0 0
0
2013
Notes
Remedial Action
Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-04-0-023 01 - Decorations
B(C)
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
C
£1,225
0
3
0 0
0
2009
B(C)
£78
3
4
0 0
0
2012
02 - Ceiling
B
£0
8
0
0 0
0
2017
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
10
0
0 0
0
2019
B(C)
£78
3
4
0 0
0
2012
02 - Ceiling
B
£0
8
0
0 0
0
2017
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
10
0
0 0
0
2019
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet.
Location: 001-04-0-023a 01 - Decorations
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-04-0-023b 01 - Decorations
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-04-0-023c Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
B(C)
Cost to B Rem Life Priority C L
R
Year
£208
3
4
0 0
0
2012
02 - Ceiling
B
£0
8
0
0 0
0
2017
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£104
3
4
0 0
0
2012
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-04-0-023d 01 - Decorations
B(C)
02 - Ceiling
B
£0
8
0
0 0
0
2017
03 - Floor
B
£0
8
0
0 0
0
2017
£312
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
B(C)
£420
4
3
0 0
0
2013
01 - Decorations
B(C)
£650
2
4
0 0
0
2011
02 - Ceiling
B(C)
£3,000
4
2
0 0
0
2013
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition.
Location: 001-04-0-024 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-025
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£875
2
3
0 0
0
2011
Vinyl sheet: Requires replacement within the maintenance schedule due to age and condition.
C
£208
0
4
0 0
0
2009
B(C)
£960
4
2
0 0
0
2013
B
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Quarry tile flooring: In good condition.
C
£78
0
4
0 0
0
2009
B(C)
£360
4
2
0 0
0
2013
£0
6
0
0 0
0
2015
B(C)
£1,250
2
3
0 0
0
2011
01 - Decorations
B(C)
£1,560
1
4
0 0
0
2010
02 - Ceiling
B(C)
£7,200
4
2
0 0
0
2013
Location: 001-04-0-026 01 - Decorations
02 - Ceiling
03 - Floor
Location: 001-04-0-027 01 - Decorations
02 - Ceiling
03 - Floor 08 - Fixed Units
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Quarry tile flooring: In good condition. Fixed unit: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-04-0-028
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
£2,100
1
3
0 0
0
2010
08 - Fixed Units
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
6
0
0 0
0
2015
B(C)
£208
2
4
0 0
0
2011
C
£960
0
2
0 0
0
2009
B(C)
£280
4
3
0 0
0
2013
B(C)
£520
2
4
0 0
0
2011
Notes
Remedial Action
Vinyl sheet: Requires replacement within the maintenance schedule due to age and condition. Fixed units: Art units in good condition. Fixed units: Belfast sink unit in good condition.
Location: 001-04-0-028a 01 - Decorations
02 - Ceiling
03 - Floor
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-029 01 - Decorations
02 - Ceiling
C
£2,400
0
2
0 0
0
2009
03 - Floor
B
£0
8
0
0 0
0
2017
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Anti-slip vinyl sheet flooring: In good condition.
Location: 001-04-0-030 01 - Decorations
B(C)
£520
2
4
0 0
0
2011
02 - Ceiling
B(C)
£2,400
4
2
0 0
0
2013
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
C
£1,250
0
3
0 0
0
2009
£650
4
4
0 0
0
2013
£0
20
0
0 0
0
2029
B(C)
£875
2
3
0 0
0
2011
01 - Decorations
B(C)
£520
4
4
0 0
0
2013
02 - Ceiling
B(C)
£2,400
5
2
0 0
0
2014
03 - Floor
B(C)
£700
2
3
0 0
0
2011
B(C)
£3,900
5
4
0 0
0
2014
£250
0
3
0 0
0
2009
£5,250
2
3
0 0
0
2011
Notes
Remedial Action
Anti-slip vinyl sheet flooring: In good condition. Fixed units: Sink unit requires replacement due to age and level of deterioration.
Location: 001-04-0-031 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Vinyl sheet: Requires replacement within the maintenance schedule due to age and condition.
Location: 001-04-0-032 Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Vinyl sheet: Requires replacement within the maintenance schedule due to age and condition.
Location: 001-04-0-033 01 - Decorations
02 - Ceiling 03 - Floor
Sample College Physical Condition Survey
C B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Vinyl sheet: Requires replacement within the maintenance schedule due to age and condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-04-0-033a 01 - Decorations
B(C)
£156
4
4
0 0
0
2013
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
C
£210
0
3
0 0
0
2009
B(C)
£260
4
4
0 0
0
2013
C
£100
0
3
0 0
0
2009
B(C)
£350
5
3
0 0
0
2014
B(C)
£312
4
4
0 0
0
2013
C
£100
0
3
0 0
0
2009
B(C)
£420
5
3
0 0
0
2014
01 - Decorations
C
£312
0
4
0 0
0
2009
02 - Ceiling
B
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Vinyl sheet: Requires replacement due to age and condition.
Location: 001-04-0-033b 01 - Decorations
02 - Ceiling 03 - Floor
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-033c 01 - Decorations
02 - Ceiling 03 - Floor
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-034
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£420
4
3
0 0
0
2013
Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
01 - Decorations
C
£312
0
4
0 0
0
2009
02 - Ceiling
B
£0
6
0
0 0
0
2015
B(C)
£420
1
3
0 0
0
2010
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£1,560
4
4
0 0
0
2013
£0
20
0
0 0
0
2029
B(C)
£2,100
4
3
0 0
0
2013
B(C)
£1,040
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
£1,400
4
3
0 0
0
2013
Location: 001-04-0-035
03 - Floor
Location: 001-04-0-036 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-037 01 - Decorations
02 - Ceiling 03 - Floor
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-038 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
£1,040
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
B(C)
£1,400
4
3
0 0
0
2013
B(C)
£78
4
4
0 0
0
2013
B
£0
20
0
0 0
0
2029
B(C)
£105
4
3
0 0
0
2013
B(C)
£260
4
4
0 0
0
2013
£0
20
0
0 0
0
2029
B(C)
£350
4
3
0 0
0
2013
B(C)
£104
1
4
0 0
0
2010
£0
6
0
0 0
0
2015
B
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-038a 01 - Decorations
02 - Ceiling 03 - Floor
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-038b 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-038c 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
C
£140
0
3
0 0
0
2009
Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
01 - Decorations
C
£78
0
4
0 0
0
2009
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Quarry tile flooring: In good condition.
£4,550
5
4
0 0
0
2014
£250
0
3
0 0
0
2009
B(C)
£6,125
4
3
0 0
0
2013
B(C)
£780
4
4
0 0
0
2013
£0
15
0
0 0
0
2024
£1,050
5
3
0 0
0
2014
Location: 001-04-0-038d
Location: 001-04-0-039 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
C
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Vinyl sheet: Requires replacement within the maintenance schedule due to age and condition.
Location: 001-04-0-040 01 - Decorations
02 - Ceiling 03 - Floor
B B(C)
Redecoration required as part of a regular maintenance schedule. Timber panelling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-040b
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
£208
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
B(C)
£280
5
3
0 0
0
2014
B(C)
£104
1
4
0 0
0
2010
B
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-040c 01 - Decorations
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
C
£140
0
3
0 0
0
2009
01 - Decorations
C
£312
0
4
0 0
0
2009
02 - Ceiling
C
£312
0
2
0 0
0
2009
03 - Floor
C
£420
0
3
0 0
0
2009
01 - Decorations
C
£208
0
4
0 0
0
2009
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
C
£280
0
3
0 0
0
2009
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Vinyl tile flooring: Requires replacement due to age and condition.
Location: 001-04-0-041 Redecoration required as part of a regular maintenance schedule. Ceiling paper: Requires replacement. Carpet: Requires replacement with contract quality carpet.
Location: 001-04-0-041a
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Vinyl tile flooring: Requires replacement due to age and condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-04-0-042 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
£650
2
4
0 0
0
2011
£0
10
0
0 0
0
2019
B(C)
£875
2
3
0 0
0
2011
B(C)
£208
2
4
0 0
0
2011
£0
10
0
0 0
0
2019
B(C)
£280
2
3
0 0
0
2011
B(C)
£650
2
4
0 0
0
2011
£0
10
0
0 0
0
2019
B(C)
£875
4
3
0 0
0
2013
B(C)
£1,300
2
4
0 0
0
2011
B
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Vinyl tile flooring: Requires replacement within the maintenance schedule due to age and condition.
Location: 001-04-0-042a 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Vinyl tile flooring: Requires replacement within the maintenance schedule due to age and condition.
Location: 001-04-0-043 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-044 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02 - Ceiling 03 - Floor
08 - Fixed Units
B B(C)
B
Cost to B Rem Life Priority C L
R
Year
£0
10
0
0 0
0
2019
£1,750
2
3
0 0
0
2011
£0
6
0
0 0
0
2015
Notes
Remedial Action
Plaster ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-04-0-101 01 - Decorations
B(C)
£4,550
4
4
0 0
0
2013
02 - Ceiling 03 - Floor
B B(C)
£0 £6,125
40 5
0 3
0 0 0 0
0 0
2049 2014
B
£0
8
0
0 0
0
2017
02 - Ceiling
B
£0
20
0
0 0
0
2029
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
20
0
0 0
0
2029
02 - Ceiling
B
£0
20
0
0 0
0
2029
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
20
0
0 0
0
2029
03 - Floor
Redecoration required as part of a regular maintenance schedule. Exposed decking: Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Timber floor: In good condition.
Location: 001-04-0-101a Plaster ceiling: In good condition. Vinyl sheet flooring: In good condition. Fairfaced blockwork: In good condition.
Location: 001-04-0-101b Plaster ceiling: In good condition. Vinyl sheet flooring: In good condition. Fairfaced blockwork: In good condition.
Location: 001-04-0-C1 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
£1,300
2
4
0 0
0
2011
£150
0
3
0 0
0
2009
B(C)
£1,750
2
3
0 0
0
2011
B(C)
£2,600
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£3,500
2
3
0 0
0
2011
B(C)
£2,600
4
4
0 0
0
2013
£0
10
0
0 0
0
2019
B(C)
£3,500
2
3
0 0
0
2011
B(C)
£1,560
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
C
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-C2 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-C3 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-0-C4 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£2,100
2
3
0 0
0
2011
Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
01 - Decorations
B(C)
£2,600
3
4
0 0
0
2012
02 - Ceiling
B(C)
£12,000
4
2
0 0
0
2013
03 - Floor
B(C)
£3,500
2
3
0 0
0
2011
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
B(C)
£520
4
4
0 0
0
2013
£0
20
0
0 0
0
2029
B(C)
£700
5
3
0 0
0
2014
01 - Decorations
C
£390
0
4
0 0
0
2009
02 - Ceiling
C
£1,800
0
2
0 0
0
2009
03 - Floor
C
£525
0
3
0 0
0
2009
Location: 001-04-0-C5
Location: 001-04-1-001 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-LG-045
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Vinyl tile flooring: Requires replacement due to age and condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-04-LG-045a 01 - Decorations
C
£312
0
4
0 0
0
2009
02 - Ceiling
B
£0
20
0
0 0
0
2029
03 - Floor
C
£420
0
3
0 0
0
2009
01 - Decorations
C
£156
0
4
0 0
0
2009
02 - Ceiling
B
£0
20
0
0 0
0
2029
B(C)
£210
2
3
0 0
0
2011
01 - Decorations
B(C)
£520
4
4
0 0
0
2013
02 - Ceiling
B(C)
£2,400
2
2
0 0
0
2011
£0
8
0
0 0
0
2017
£1,300
3
4
0 0
0
2012
£150
0
3
0 0
0
2009
Redecoration required as part of a regular maintenance schedule. Concrete decking: In good condition. Carpet tiles: Require replacement with contract quality carpet.
Location: 001-04-LG-045b
03 - Floor
Redecoration required as part of a regular maintenance schedule. Concrete decking: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-LG-045c
03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Anti-slip vinyl sheet flooring: In good condition.
Location: 001-04-LG-045d 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B(C)
C
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
B
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£0
6
0
0 0
0
2015
Anti-slip vinyl sheet flooring: In good condition.
£1,040
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
B(C)
£1,400
4
3
0 0
0
2013
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£650
4
4
0 0
0
2013
C
£150
0
3
0 0
0
2009
B(C)
£875
4
3
0 0
0
2013
B(C)
£10,400
4
4
0 0
0
2013
Location: 001-04-LG-046 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Location: 001-04-LG-048 01 - Decorations
02 - Ceiling 03 - Floor
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-LG-049 01 - Decorations
02 - Ceiling
B
£0
20
0
0 0
0
2029
02 - Ceiling
B
£0
20
0
0 0
0
2029
03 - Floor
B
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Plaster ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition.
Location: 001-04-LG-050
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
B(C)
Cost to B Rem Life Priority C L
R
Year
£5,200
4
4
0 0
0
2013
02 - Ceiling
B
£0
20
0
0 0
0
2029
03 - Floor
B
£0
6
0
0 0
0
2015
B(C)
£1,250
2
3
0 0
0
2011
B(C)
£390
4
4
0 0
0
2013
08 - Fixed Units
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-04-LG-051 01 - Decorations
02 - Ceiling
B
£0
20
0
0 0
0
2029
03 - Floor
B
£0
8
0
0 0
0
2017
£130
4
4
0 0
0
2013
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Vinyl sheet flooring: In good condition.
Location: 001-04-LG-051a 01 - Decorations
B(C)
02 - Ceiling
B
£0
20
0
0 0
0
2029
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
8
0
0 0
0
2017
£390
4
4
0 0
0
2013
£0
20
0
0 0
0
2029
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-04-LG-052 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£525
1
3
0 0
0
2010
Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£130
4
4
0 0
0
2013
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-04-LG-052a 01 - Decorations
02 - Ceiling
B
£0
20
0
0 0
0
2029
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
8
0
0 0
0
2017
B(C)
£600
4
2
0 0
0
2013
03 - Floor
C
£175
0
3
0 0
0
2009
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
6
0
0 0
0
2015
C
£208
0
4
0 0
0
2009
B(C)
£960
4
2
0 0
0
2013
C
£280
0
3
0 0
0
2009
Location: 001-04-LG-053 02 - Ceiling
Suspended ceiling: Requires replacement within the maintenance schedule. Anti-slip vinyl sheet flooring: Requires replacement due to age and condition. Ceramic wall tiling: In good condition. Fixed units: Steel kitchen units in good condition.
Location: 001-04-LG-053a 01 - Decorations
02 - Ceiling
03 - Floor
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Anti-slip vinyl sheet flooring: Requires replacement due to age and condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 08 - Fixed Units
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
6
0
0 0
0
2015
Fixed units: Sink unit in good condition.
C
£312
0
4
0 0
0
2009
£1,440
4
2
0 0
0
2013
C
£420
0
3
0 0
0
2009
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Anti-slip vinyl sheet flooring: Requires replacement due to age and condition.
01 - Decorations
B(C)
£312
1
4
0 0
0
2010
02 - Ceiling
B(C)
£1,440
4
2
0 0
0
2013
£0
6
0
0 0
0
2015
£1,440
4
2
0 0
0
2013
Location: 001-04-LG-053b 01 - Decorations
02 - Ceiling
03 - Floor
B(C)
Location: 001-04-LG-053c
03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Quarry tile flooring: In good condition.
Location: 001-04-LG-053d 02 - Ceiling
B(C)
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
£910
1
4
0 0
0
2010
Suspended ceiling: Requires replacement within the maintenance schedule. Concrete flooring: In good condition. Plastic Sheet walls: In good condition.
Location: 001-04-LG-054 01 - Decorations
Sample College Physical Condition Survey
B(C)
Redecoration required as part of a regular maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
02 - Ceiling
B(C)
£4,200
4
2
0 0
0
2013
03 - Floor
B(C)
£1,225
2
3
0 0
0
2011
Suspended ceiling: Requires replacement within the maintenance schedule. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition.
B
£0
6
0
0 0
0
2015
Plant room fit for purpose.
B
£0
6
0
0 0
0
2015
Plant room fit for purpose.
B
£0
6
0
0 0
0
2015
Plant room fit for purpose.
£130
1
4
0 0
0
2010
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-04-LG-055 12 - Comments
Location: 001-04-LG-056 12 - Comments
Location: 001-04-LG-057 12 - Comments
Location: 001-04-LG-058 01 - Decorations
B(C)
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
10
0
0 0
0
2019
B(C)
£78
1
4
0 0
0
2010
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
10
0
0 0
0
2019
Location: 001-04-LG-058a 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-04-LG-059 01 - Decorations
B(C)
£312
1
4
0 0
0
2010
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£130
1
4
0 0
0
2010
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-04-LG-059a 01 - Decorations
B(C)
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£5,200
3
4
0 0
0
2012
£0
15
0
0 0
0
2024
B(C)
£7,000
4
3
0 0
0
2013
B(C)
£130
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-04-LG-060 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Timber ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-04-LG-060a 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02 - Ceiling 03 - Floor
B
Cost to B Rem Life Priority C L
R
Year
£0
20
0
0 0
0
2029
B(C)
£175
2
3
0 0
0
2011
B(C)
£260
2
4
0 0
0
2011
£0
20
0
0 0
0
2029
Notes
Remedial Action
Plaster ceiling: In good condition. Vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition.
Location: 001-04-LG-060b 01 - Decorations
02 - Ceiling
B
03 - Floor
B(C)
£350
2
3
0 0
0
2011
08 - Fixed Units
B(C)
£1,250
2
3
0 0
0
2011
08 - Fixed Units
B(C)
£5,000
2
3
0 0
0
2011
£0
20
0
0 0
0
2029
£350
2
3
0 0
0
2011
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration. Timber Bar - is in poor condition with replacement required within the maintenance period.
Location: 001-04-LG-060c 02 - Ceiling 03 - Floor
B B(C)
05 - Condition of Internal Walls
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
8
0
0 0
0
2017
Plaster ceiling: In good condition. Vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-04-LG-060d Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£260
1
4
0 0
0
2010
£0
15
0
0 0
0
2024
£350
2
3
0 0
0
2011
B B B B B
£0 £0 £0 £0 £0
20 50 50 10 10
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
2029 2059 2059 2019 2019
Metal sheet. Metal. Metal. Aluminium. PVCU.
B B C
£0 £0 £1,000
20 30 0
0 0 3
0 0 0 0 0 0
0 0 0
2029 2039 2009
B B B B
£0 £0 £0 £0
50 50 10 10
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2059 2059 2019 2019
Metal sheet. Timber. Painted timber: Redecorate complete. Metal. Timber. PVCU. PVCU.
B
£0
10
0
0 0
0
2019
Aluminium Velux.
£0 £0 £1,000
8 15 1
0 0 3
0 0 0 0 0 0
0 0 0
2017 2024 2010
Concrete tile. Mineral felt. Painted timber: Redecorate complete.
B B(C)
Redecoration required as part of a regular maintenance schedule. Timber ceiling: In good condition. Vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition.
D - Building - Roof
Location: Roof 01 01a - Attached - Covering 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering 01h - Attached - Down Rainwater pipes
Location: Roof 02 01a - Attached - Covering 01b - Attached - Sarking 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering 01h - Attached - Down Rainwater pipes 01i - Attached - Skylights
Location: Roof 03 01a - Attached - Covering 01b - Attached - Sarking 01d - Attached - Verges/Fascias/ Soffits Sample College Physical Condition Survey
B B B(C)
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
R
Year
£0
8
0
0 0
0
2017
B B B(C)
£0 £0 £1,250
40 40 2
0 0 2
0 0 0 0 0 0
0 0 0
2049 2049 2011
B(C)
£600
2
2
0 0
0
2011
01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
B B B B(C)
£0 £0 £0 £250
8 15 15 5
0 0 0 3
0 0 0 0
0 0 0 0
0 0 0 0
2017 2024 2024 2014
B B B(C)
£0 £0 £250
40 40 2
0 0 2
0 0 0 0 0 0
0 0 0
2049 2049 2011
01h - Attached - Down Rainwater pipes
B(C)
£100
2
2
0 0
0
2011
£0 £0 £0 £0 £0
8 15 15 40 40
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
2017 2024 2024 2049 2049
01h - Attached - Down Rainwater pipes
B
Cost to B Rem Life Priority C L
Notes
Remedial Action
Hanging clay tiles: Located to eaves. Timber. Timber. PVCU: Evidence of deterioration with replacement likely to be required within the maintenance period. PVCU: Evidence of deterioration with replacement likely to be required within the maintenance period.
Location: Roof 04 Concrete tile. Mineral felt. Lead. Painted timber: Redecorate complete. Timber. Timber. PVCU: Evidence of deterioration with replacement likely to be required within the maintenance period. PVCU: Evidence of deterioration with replacement likely to be required within the maintenance period.
Location: Roof 05 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01e - Attached - Rafters 01f - Attached - Purlins Sample College Physical Condition Survey
B B B B B
0 0 0 0 0
Single ply membrane. Timber. Lead. Timber. Timber. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
01g - Attached - Guttering
C
£250
0
2
0 0
0
2009
Integrated: Requires the implementation of a regular clearing programme. PVCU - Internal.
01h - Attached - Down Rainwater pipes 01i - Attached - Skylights
B
£0
6
0
0 0
0
2015
B
£0
6
0
0 0
0
2015
Polycarbonate domed skylights (4No).
£35,000
4
2
0 0
0
2013
Mineral felt with stone chippings: Evidence of deterioration with replacement required within the maintenance period. Timber. Lead. Timber. Timber. Integrated: Requires the implementation of a regular clearing programme. PVCU - Internal.
Location: Roof 06 01a - Attached - Covering
B(C)
01b - Attached - Sarking 01c - Attached - Flashing 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
B B B B C
£0 £0 £0 £0 £250
6 15 40 40 0
0 0 0 0 2
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
2015 2024 2049 2049 2009
01h - Attached - Down Rainwater pipes 01i - Attached - Skylights
B
£0
6
0
0 0
0
2015
£3,000
4
2
0 0
0
2013
Polycarbonate domed skylights (5No.): Evidence of deterioration with replacement required within the maintenance period.
Single ply membrane. Timber. Rendered brick with stone coping. PVCU - Internal.
B(C)
Location: Roof 07 02a - Flat - Covering 02b - Flat - Decking 02d - Flat - Parapets
B B B
£0 £0 £0
10 15 10
0 0 0
0 0 0 0 0 0
0 0 0
2019 2024 2019
02h - Flat - Down Rainwater pipes
B
£0
10
0
0 0
0
2019
Location: Roof 08 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02a - Flat - Covering 02b - Flat - Decking 02c - Flat - Flashing 02e - Flat - Verges/Fascias/ Soffits 02h - Flat - Down Rainwater pipes
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B B B B B
£0 £0 £0 £0 £0
10 15 15 10 10
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
2019 2024 2024 2019 2019
Single ply membrane. Timber. Lead. Composite fibre board. PVCU - Internal.
B B B B
£0 £0 £0 £0
10 15 8 10
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2019 2024 2017 2019
Single ply membrane. Timber. PVCU. PVCU - Internal.
02a - Flat - Covering
C
£50,000
0
1
0 0
0
2009
02b - Flat - Decking
C
£0
0
1
0 0
0
2009
£400
4
2
0 0
0
2013
£0
6
0
0 0
0
2015
Mineral felt with solar reflective covering: Evidence of deterioration to the covering with complete replacement required. Woodwool: Replacement required with roof covering. Cost included. PVCU - part Internal: Require replacing due to age and condition. Polycarbonate domed skylights (6No).
Location: Roof 09 02a - Flat - Covering 02b - Flat - Decking 02e - Flat - Verges/Fascias/ Soffits 02h - Flat - Down Rainwater pipes
Location: Roof 10
02h - Flat - Down Rainwater pipes
02i - Flat - Skylights
B(C)
B
Location: Roof 11 02a - Flat - Covering
B(C)
£2,000
1
2
0 0
0
2010
02b - Flat - Decking
B(C)
£0
1
2
0 0
0
2010
£250
0
1
0 0
0
2009
02f - Flat - Drainage Fall
Sample College Physical Condition Survey
C
Mineral felt: Requires replacing due to age and condition. Woodwool: Replacement required with roof covering. Cost included. Mineral felt: Evidence of significant standing water with investigation into drainage outlets required. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02h - Flat - Down Rainwater pipes
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
6
0
0 0
0
2015
PVCU - Internal.
02a - Flat - Covering
C
£60,000
0
1
0 0
0
2009
02b - Flat - Decking
C
£0
0
1
0 0
0
2009
B B(C)
£0 £16,200
6 4
0 2
0 0 0 0
0 0
2015 2013
Mineral felt with solar reflective covering: Evidence of deterioration of the covering with complete replacement required. Woodwool: Replacement required with roof covering. Cost included. PVCU - Internal. Polycarbonate domed skylights (27No.): Evidence of minor sun damage with replacement within the maintenance period likely to be required.
02a - Flat - Covering
C
£17,500
0
1
0 0
0
2009
02b - Flat - Decking
C
£0
0
1
0 0
0
2009
02h - Flat - Down Rainwater pipes 02i - Flat - Skylights
B C
£0 £20,000
6 0
0 1
0 0 0 0
0 0
2015 2009
Location: Roof 12
02h - Flat - Down Rainwater pipes 02i - Flat - Skylights
Location: Roof 13 Mineral felt with solar reflective covering: Evidence of deterioration of the covering with complete replacement required. Woodwool: Replacement required with roof covering. Cost included. Roof drains directly onto roof 16. Aluminium framed North lights with Georgian wire glazing: In poor condition with evidence of failure to seals, complete replacement required.
Location: Roof 14
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
02a - Flat - Covering
C
£2,500
0
1
0 0
0
2009
02b - Flat - Decking
C
£0
0
1
0 0
0
2009
02h - Flat - Down Rainwater pipes 02i - Flat - Skylights
B B
£0 £0
6 6
0 0
0 0 0 0
0 0
2015 2015
02a - Flat - Covering
C
£60,000
0
1
0 0
0
2009
02b - Flat - Decking
C
£0
0
1
0 0
0
2009
02h - Flat - Down Rainwater pipes 02i - Flat - Skylights
B C
£0 £600
6 0
0 1
0 0 0 0
0 0
2015 2009
B(C)
£3,000
4
2
0 0
0
2013
B(C)
£45,000
4
2
0 0
0
2013
Notes
Remedial Action
Mineral felt with solar reflective covering: Evidence of deterioration of the covering with complete replacement required. Woodwool: Replacement required with roof covering. Cost included. Roof drains directly onto roof 16. Polycarbonate domed skylights (2No).
Location: Roof 15
02i - Flat - Skylights
Mineral felt with solar reflective covering: Evidence of deterioration of the covering with complete replacement required. Woodwool: Replacement required with roof covering. Cost included. PVCU - Internal. Polycarbonate domed skylights (1No.): Evidence of significant sun damage with replacement required. Polycarbonate domed skylights (5No.): Evidence of deterioration with replacement required within the maintenance period.
Location: Roof 16 02a - Flat - Covering
Sample College Physical Condition Survey
Mineral with stone chippings: Evidence of deterioration with replacement required within the maintenance period.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02b - Flat - Decking
B(C)
02c - Flat - Flashing
Cost to B Rem Life Priority C L
R
Year
£0
4
2
0 0
0
2013
C
£4,000
0
1
0 0
0
2009
B B(C)
£0 £5,400
6 4
0 2
0 0 0 0
0 0
2015 2013
02a - Flat - Covering
B(C)
£15,000
4
2
0 0
0
2013
02b - Flat - Decking
B(C)
£0
4
2
0 0
0
2013
02c - Flat - Flashing
C
£1,000
0
1
0 0
0
2009
£0 £600
6 2
0 2
0 0 0 0
0 0
2015 2011
02h - Flat - Down Rainwater pipes 02i - Flat - Skylights
Notes
Remedial Action
Woodwool: Replacement required with roof covering. Cost included. Lead: Evidence of the removal of the flashing as a result of theft with part of the flashing already replaced with a lead substitute. Cost allows for further replacement. PVCU - Internal. Polycarbonate domed skylights (9No.): Evidence of deterioration with replacement required.
Location: Roof 17
02h - Flat - Down Rainwater pipes 02i - Flat - Skylights
B B(C)
Mineral with stone chippings: Evidence of deterioration with replacement required within the maintenance period. Woodwool: Replacement required with roof covering. Cost included. Lead: Evidence of the removal of the flashing as a result of theft with part of the flashing already replaced with a lead substitute. Cost allows for further replacement. PVCU - Internal. Polycarbonate domed skylights (1No.): Evidence of deterioration with replacement required.
Location: Roof 18
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02a - Flat - Covering
B(C)
02b - Flat - Decking 02c - Flat - Flashing
B C
02d - Flat - Parapets
B(C)
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£50,000
5
2
0 0
0
2014
Asphalt: Evidence of deterioration with re-covering likely to be required within the maintenance period. Reinforced concrete. Lead: Evidence of flashing coming away from the wall with making good required. Concrete wall part covered with mineral felt: Evidence of localised deterioration with making good required.
£0 £250
10 0
0 1
0 0 0 0
0 0
2019 2009
£1,250
1
2
0 0
0
2010
B B B B B B
£0 £0 £0 £0 £0 £0
10 20 10 10 10 10
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
2019 2029 2019 2019 2019 2019
Single ply membrane. Metal. Lead. Zinc. PVCU - Internal. Aluminium framed glazed skylight.
01 - Heat Emitters
C
£250
0
2
0 0
0
2009
01 - Heat Emitters
B(C)
£3,000
5
3
0 0
0
2014
High efficiency convector with no low surface temperature cover require replacement. Perimeter heating sill line requires upgrading within the maintenance schedule.
£250
0
2
0 0
0
2009
Location: Roof 19 02a - Flat - Covering 02b - Flat - Decking 02c - Flat - Flashing 02e - Flat - Verges/Fascias/ Soffits 02h - Flat - Down Rainwater pipes 02i - Flat - Skylights
Facet: 2 - Engineering I - Engineering - Heating Systems
Location: 001-04-1-001/2/3
Location: 001-04-1-005 01 - Heat Emitters
Sample College Physical Condition Survey
C
High efficiency convector with no low surface temperature cover require replacement. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-04-1-005b 01 - Heat Emitters
C
£400
0
2
0 0
0
2009
Fan convector requires replacement.
B(C)
£2,000
5
3
0 0
0
2014
Perimeter heating sill line requires upgrading within the maintenance schedule.
B(C)
£2,000
5
3
0 0
0
2014
Perimeter heating sill line requires upgrading within the maintenance schedule.
B
£0
10
0
0 0
0
2019
Steel panel radiator in good order.
B
£0
10
0
0 0
0
2019
Steel panel radiator in good order.
B
£0
10
0
0 0
0
2019
Steel panel radiator in good order.
£400
3
3
0 0
0
2012
Fan convector requires upgrading within the maintenance schedule.
Location: 001-04-1-006 01 - Heat Emitters
Location: 001-04-1-007 01 - Heat Emitters
Location: 001-04-1-008a 01 - Heat Emitters
Location: 001-04-1-009 01 - Heat Emitters
Location: 001-04-1-011 01 - Heat Emitters
Location: 001-04-1-012 01 - Heat Emitters
B(C)
Location: 001-04-1-012a Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£800
3
3
0 0
0
2012
2No. fan convectors require upgrading within the maintenance schedule.
B(C)
£400
2
3
0 0
0
2011
Fan convector requires upgrading within the maintenance schedule.
B
£0
10
0
0 0
0
2019
Fan convector in good order.
B
£0
10
0
0 0
0
2019
2No. heat emitters with low surface temperature covers in good order.
£400
3
3
0 0
0
2012
Fan convector requires upgrading within the maintenance schedule.
B
£0
10
0
0 0
0
2019
Fan convector in good order.
B
£0
10
0
0 0
0
2019
Steel panel radiator in good order.
B(C)
£500
5
3
0 0
0
2014
Perimeter heating sill line requires upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Fan convector requires upgrading within the maintenance schedule.
Location: 001-04-1-012b 01 - Heat Emitters
Location: 001-04-1-012c 01 - Heat Emitters
Location: 001-04-1-012d 01 - Heat Emitters
Location: 001-04-1-012e 01 - Heat Emitters
B(C)
Location: 001-04-1-013 01 - Heat Emitters
Location: 001-04-1-014 01 - Heat Emitters
Location: 001-04-1-015 01 - Heat Emitters
Location: 001-04-1-016 01 - Heat Emitters
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-04-1-017b 01 - Heat Emitters
B(C)
£400
3
3
0 0
0
2012
Fan convector requires upgrading within the maintenance schedule.
£0
10
0
0 0
0
2019
Electric convector in good order.
£400
3
3
0 0
0
2012
Fan convector requires upgrading within the maintenance schedule.
£0
10
0
0 0
0
2019
Steel panel radiator in good order at high level.
B(C)
£800
3
3
0 0
0
2012
2No. fan convectors require upgrading within the maintenance schedule.
B(C)
£800
3
3
0 0
0
2012
2No. fan convectors require upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Fan convector requires upgrading within the maintenance schedule.
£0
10
0
0 0
0
2019
Heat emitter with low surface temperature cover in good order.
Location: 001-04-1-017c 01 - Heat Emitters
B
Location: 001-04-1-018 01 - Heat Emitters
B(C)
Location: 001-04-1-018a 01 - Heat Emitters
B
Location: 001-04-1-019 01 - Heat Emitters
Location: 001-04-1-020 01 - Heat Emitters
Location: 001-04-1-021 01 - Heat Emitters
Location: 001-04-1-022b 01 - Heat Emitters
B
Location: 001-04-1-022d Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
10
0
0 0
0
2019
Heat emitter with low surface temperature cover in good order.
B
£0
10
0
0 0
0
2019
Heat emitter with low surface temperature cover in good order.
B
£0
10
0
0 0
0
2019
Fan convector in good order.
B
£0
10
0
0 0
0
2019
Heat emitter with low surface temperature cover in good order.
B
£0
10
0
0 0
0
2019
Heat emitter with low surface temperature cover in good order.
B
£0
10
0
0 0
0
2019
Steel panel radiator in good order.
B(C)
£800
3
3
0 0
0
2012
2No. fan convectors require upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Fan convector requires upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Fan convector requires upgrading within the maintenance schedule.
Location: 001-04-1-022e 01 - Heat Emitters
Location: 001-04-1-023 01 - Heat Emitters
Location: 001-04-1-023c 01 - Heat Emitters
Location: 001-04-1-023d 01 - Heat Emitters
Location: 001-04-1-024 01 - Heat Emitters
Location: 001-04-1-028 01 - Heat Emitters
Location: 001-04-1-029 01 - Heat Emitters
Location: 001-04-1-030 01 - Heat Emitters
Location: 001-04-1-031 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£400
3
3
0 0
0
2012
Fan convector requires upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Fan convector requires upgrading within the maintenance schedule.
B(C)
£800
3
3
0 0
0
2012
2No. fan convectors require upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Fan convector requires upgrading within the maintenance schedule.
B
£0
10
0
0 0
0
2019
Heat emitter with low surface temperature cover in good order.
B
£0
10
0
0 0
0
2019
Heat emitter with low surface temperature cover in good order.
B
£0
10
0
0 0
0
2019
Heat emitter with low surface temperature cover in good order.
£800
3
3
0 0
0
2012
2No. fan convectors require upgrading within the maintenance schedule.
Location: 001-04-1-032 01 - Heat Emitters
Location: 001-04-1-036 01 - Heat Emitters
Location: 001-04-1-040 01 - Heat Emitters
Location: 001-04-1-042 01 - Heat Emitters
Location: 001-04-1-043 01 - Heat Emitters
Location: 001-04-1-044 01 - Heat Emitters
Location: 001-04-1-C1 01 - Heat Emitters
B(C)
Location: 001-04-1-C2
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£1,200
3
3
0 0
0
2012
3No. fan convectors require upgrading within the maintenance schedule.
01 - Heat Emitters
C
£1,000
0
2
0 0
0
2009
2No. pipe coils require replacement.
01 - Heat Emitters
B(C)
£800
3
3
0 0
0
2012
2No. fan convectors require upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Fan convector requires upgrading within the maintenance schedule.
01 - Heat Emitters
B(C)
£400
3
3
0 0
0
2012
01 - Heat Emitters
B
£0
10
0
0 0
0
2019
2No. fan convectors require upgrading within the maintenance schedule. Skirting heater in good order.
B(C)
£400
3
3
0 0
0
2012
Fan convector requires upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Fan convector requires upgrading within the maintenance schedule.
Location: 001-04-1-C3
Location: 001-04-1-C4 01 - Heat Emitters
Location: 001-04-1-C5
Location: 001-04-LG-045 01 - Heat Emitters
Location: 001-04-LG-045c 01 - Heat Emitters
Location: 001-04-LG-046 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
C
£400
0
2
0 0
0
2009
Fan convector requires replacement.
C
£400
0
2
0 0
0
2009
Fan convector requires replacement.
B
£0
10
0
0 0
0
2019
Underfloor heating in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
10
0
0 0
0
2019
Vent in good order.
B
£0
10
0
0 0
0
2019
Vent in good order.
Location: 001-04-LG-048 01 - Heat Emitters
Location: 001-04-LG-049 01 - Heat Emitters
Location: 001-04-LG-050 01 - Heat Emitters
Location: 001-04-LG-051 01 - Heat Emitters
Location: 001-04-LG-051a 01 - Heat Emitters
Location: 001-04-LG-052 01 - Heat Emitters
Location: 001-04-LG-052a 01 - Heat Emitters K - Engineering - Vent & Air Con
Location: 001-04-1-022b 03 - Grilles & Diffusers
Location: 001-04-1-022c 03 - Grilles & Diffusers Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-04-1-022d 03 - Grilles & Diffusers
B
£0
10
0
0 0
0
2019
Vent in good order.
B
£0
10
0
0 0
0
2019
Vent in good order.
B
£0
10
0
0 0
0
2019
Vent in good order.
B
£0
10
0
0 0
0
2019
Vent in good order.
B
£0
10
0
0 0
0
2019
Vent in good order.
B
£0
10
0
0 0
0
2019
Vent in good order.
£2,000
2
3
0 0
0
2011
Vent is tired and requires upgrading within the maintenance schedule.
B
£0
10
0
0 0
0
2019
Air conditioning unit in good order.
B
£0
10
0
0 0
0
2019
Air conditioning unit in good order.
B
£0
10
0
0 0
0
2019
Vent in good order.
Location: 001-04-1-022e 03 - Grilles & Diffusers
Location: 001-04-1-023a 03 - Grilles & Diffusers
Location: 001-04-1-023b 03 - Grilles & Diffusers
Location: 001-04-1-023c 03 - Grilles & Diffusers
Location: 001-04-1-033 03 - Grilles & Diffusers
Location: 001-04-1-039 03 - Grilles & Diffusers
B(C)
Location: 001-04-LG-045a 05 - Cooling Units
Location: 001-04-LG-045b 05 - Cooling Units
Location: 001-04-LG-045d 03 - Grilles & Diffusers
Location: 001-04-LG-053 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Grilles & Diffusers
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£10,000
3
3
0 0
0
2012
Kitchen canopy is tired and in need of upgrade.
B(C)
£500
5
3
0 0
0
2014
Ductwork requires upgrading within the maintenance schedule.
C
£15,000
0
2
0 0
0
2009
Ductwork is very old and requires replacement.
B
£0
10
0
0 0
0
2019
Ductwork in good order.
01 - Local Water Heaters
B
£0
10
0
0 0
0
2019
03 - Blending Valves
B
£0
10
0
0 0
0
2019
Heatre Sadia under sink water heater in good order. Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
Location: 001-04-LG-055 01 - Ductwork
Location: 001-04-LG-057 01 - Ductwork
Location: 001-04-LG-060 01 - Ductwork M - Engineering - Hot/Cold Water
Location: 001-04-1-004
Location: 001-04-1-022b 03 - Blending Valves
Location: 001-04-1-022d 03 - Blending Valves
Location: 001-04-1-022e 03 - Blending Valves
Location: 001-04-1-023a Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Blending Valves
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
15
0
0 0
0
2024
Over sink water heater in good order.
C
£100,000
0
2
0 0
0
2009
2No. lifts require replacement.
B
£0
15
0
0 0
0
2024
Worcester heating boiler in good order.
C
£40,000
0
2
0 0
0
2009
4No. Potterton Derwent condensing boilers require replacement.
Location: 001-04-1-023b 03 - Blending Valves
Location: 001-04-1-023c 03 - Blending Valves
Location: 001-04-LG-052b 01 - Local Water Heaters N - Engineering - Lifts
Location: 001-04-LG-045e 01 - Lifts
O - Engineering - Main Plant
Location: 001-04-LG- 060d 01 - Heating Boilers
Location: 001-04-LG-057 01 - Heating Boilers
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
01 - Heating Boilers
B
£0
10
0
0 0
0
2019
Lochinvar boiler serving two (No Suggestions) calorifiers in good order. Domestic hot water service flow pump newly installed in parallel which causes a deadleg issue also top pump is a heating pump.
02 - Pumps
C
£1,000
0
2
0 0
0
2009
02 - Pumps
C
£3,000
0
2
0 0
0
2009
Grundfos heating pump requires replacement.
02 - Pumps
B
£0
12
0
0 0
0
2021
02 - Pumps
B
£0
15
0
0 0
0
2024
£10,000
5
2
0 0
0
2014
Grundfos domestic hot water service return pump in good order. 5No. Grundfos heating pumps in good order. 2No. Lochinvar calorifiers in good order will require upgrading within the maintenance schedule. Lochinvar DGF calorifier in good order.
03 - Calorifiers
B(C)
03 - Calorifiers
B
£0
12
0
0 0
0
2021
B
£0
7
0
0 0
0
2016
Extract fan in good order.
B
£0
7
0
0 0
0
2016
Extract fan in good order.
P - Engineering - Main Plant
Location: 001-04-1-014a 04 - Extract Fans
Location: 001-04-1-014b 04 - Extract Fans
Location: 001-04-1-014c Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Extract Fans
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
10
0
0 0
0
2019
Extract fan in good order.
B
£0
10
0
0 0
0
2019
Extract fan in good order.
05 - AHUs
C
£15,000
0
2
0 0
0
2009
06 - Plant Room Ventilation
B
£0
10
0
0 0
0
2019
Air handling unit is very old and requires replacement. Louvered door in good order.
B
£0
15
0
0 0
0
2024
Air handling unit in good order.
B(C)
£1,500
5
3
0 0
0
2014
Roof unit extract fan requires upgrading within the maintenance schedule.
C
£10,000
0
2
0 0
0
2009
Control panel is very old and requires replacement.
£750
5
3
0 0
0
2014
Extract fan requires upgrading within the maintenance schedule.
Location: 001-04-1-033b 04 - Extract Fans
Location: 001-04-LG- 057
Location: 001-04-LG- 060d 05 - AHUs
Location: 001-04-LG-055 04 - Extract Fans
Location: 001-04-LG-057 03 - Controls
Location: 001-04-LG-060c 04 - Extract Fans
B(C)
R - Engineering - Electrical Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-04-1-001/2/3 04 - Lighting Installation 05 - Emergency Lighting
B B
£0 £0
13 13
0 0
0 0 0 0
0 0
2022 2022
CAT II light in good order. Emergency light in good order.
B
£0
13
0
0 0
0
2022
Surface fluorescent light in good order.
B
£0
13
0
0 0
0
2022
Surface fluorescent light in good order.
B B
£0 £0
13 10
0 0
0 0 0 0
0 0
2022 2019
2No. CAT II lights in good order. Sockets and switches in good order.
C
£200
0
2
0 0
0
2009
Tungsten light requires replacement.
04 - Lighting Installation
B
£0
13
0
0 0
0
2022
05 - Emergency Lighting
B
£0
13
0
0 0
0
2022
Surface fluorescent light in good order. Emergency light in good order.
B
£0
13
0
0 0
0
2022
CAT II light in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
12No. surface fluorescent lights in good order. Sockets and switches in good order.
Location: 001-04-1-004 04 - Lighting Installation
Location: 001-04-1-004a 04 - Lighting Installation
Location: 001-04-1-005 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-04-1-005a 04 - Lighting Installation
Location: 001-04-1-005b
Location: 001-04-1-006 04 - Lighting Installation
Location: 001-04-1-007
Location: 001-04-1-008a Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation
06 - Sockets/Switches
B(C)
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£400
5
3
0 0
0
2014
2No. CAT II lights require upgrading within the maintenance schedule. Sockets and switches in good order.
B
£0
10
0
0 0
0
2019
B B
£0 £0
13 10
0 0
0 0 0 0
0 0
2022 2019
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
13 10
0 0
0 0 0 0
0 0
2022 2019
CAT II light in good order. Sockets and switches in good order.
B B B B B
£0 £0 £0 £0 £0
20 13 15 13 10
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
2029 2022 2024 2022 2019
Distribution board in good order. CAT II light in good order. CAT II light in good order. Emergency light in good order. Sockets and switches in good order.
B B B B
£0 £0 £0 £0
15 13 13 10
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2024 2022 2022 2019
Distribution board in good order. CAT II light in good order. Emergency light in good order. Sockets and switches in good order.
B B
£0 £0
20 13
0 0
0 0 0 0
0 0
2029 2022
Distribution board in good order. Surface fluorescent light in good order.
Location: 001-04-1-009 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-04-1-011 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-04-1-012 03 - Distribution Boards 04 - Lighting Installation 04 - Lighting Installation 05 - Emergency Lighting 06 - Sockets/Switches
Location: 001-04-1-012a 03 - Distribution Boards 04 - Lighting Installation 05 - Emergency Lighting 06 - Sockets/Switches
Location: 001-04-1-012b 03 - Distribution Boards 04 - Lighting Installation
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-04-1-012c 04 - Lighting Installation
B
£0
13
0
0 0
0
2022
Surface fluorescent light in good order. Sockets and switches in good order.
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
B
£0
13
0
0 0
0
2022
CAT II light in good order.
£400
5
3
0 0
0
2014
£0
10
0
0 0
0
2019
2No. surface fluorescent lights require upgrading within the maintenance schedule. Sockets and switches in good order.
£600
3
3
0 0
0
2012
Location: 001-04-1-012d 04 - Lighting Installation
Location: 001-04-1-012e 04 - Lighting Installation
06 - Sockets/Switches
B(C)
B
Location: 001-04-1-013 04 - Lighting Installation
B(C)
3No. surface fluorescent lights require upgrading within the maintenance schedule. CAT II light in good order.
04 - Lighting Installation
B
£0
13
0
0 0
0
2022
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
13 10
0 0
0 0 0 0
0 0
2022 2019
B
£0
10
0
0 0
0
2019
2No. surface fluorescent lights in good order.
£800
5
3
0 0
0
2014
4No. surface fluorescent lights require upgrading within the maintenance schedule.
Location: 001-04-1-014 Hager distribution board in good order. CAT II light in good order. Sockets and switches in good order.
Location: 001-04-1-014a 04 - Lighting Installation
Location: 001-04-1-014b 04 - Lighting Installation
Sample College Physical Condition Survey
B(C)
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-04-1-014c 03 - Distribution Boards
B
£0
20
0
0 0
0
2029
Hager distribution board in good order. Surface fluorescent light in good order.
04 - Lighting Installation
B
£0
13
0
0 0
0
2022
B
£0
13
0
0 0
0
2022
CAT II light in good order.
B B
£0 £0
13 10
0 0
0 0 0 0
0 0
2022 2019
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
13 10
0 0
0 0 0 0
0 0
2022 2019
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
13 10
0 0
0 0 0 0
0 0
2022 2019
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
13 10
0 0
0 0 0 0
0 0
2022 2019
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
13 10
0 0
0 0 0 0
0 0
2022 2019
CAT II light in good order. Sockets and switches in good order.
B
£0
13
0
0 0
0
2022
CAT II light in good order.
Location: 001-04-1-015 04 - Lighting Installation
Location: 001-04-1-016 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-04-1-017 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-04-1-017b 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-04-1-017c 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-04-1-018 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-04-1-018a 04 - Lighting Installation Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-04-1-019 04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
13 10
0 0
0 0 0 0
0 0
2022 2019
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
13 10
0 0
0 0 0 0
0 0
2022 2019
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
13 10
0 0
0 0 0 0
0 0
2022 2019
CAT II light in good order. Sockets and switches in good order.
04 - Lighting Installation
B
£0
13
0
0 0
0
2022
05 - Emergency Lighting
B
£0
13
0
0 0
0
2022
Surface fluorescent light in good order. Emergency light in good order.
B
£0
13
0
0 0
0
2022
Surface fluorescent light in good order.
B
£0
13
0
0 0
0
2022
Surface fluorescent light in good order.
B
£0
13
0
0 0
0
2022
Surface fluorescent light in good order.
B
£0
13
0
0 0
0
2022
Surface fluorescent light in good order.
Location: 001-04-1-020 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-04-1-021 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-04-1-022a
Location: 001-04-1-022b 04 - Lighting Installation
Location: 001-04-1-022c 04 - Lighting Installation
Location: 001-04-1-022d 04 - Lighting Installation
Location: 001-04-1-022e 04 - Lighting Installation
Location: 001-04-1-023 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation 06 - Sockets/Switches
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B B
£0 £0
13 10
0 0
0 0 0 0
0 0
2022 2019
CAT II light in good order. Sockets and switches in good order.
B
£0
13
0
0 0
0
2022
Surface fluorescent light in good order.
04 - Lighting Installation
B
£0
13
0
0 0
0
2022
05 - Emergency Lighting
B
£0
13
0
0 0
0
2022
Surface fluorescent light in good order. Emergency light in good order.
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B
£0
13
0
0 0
0
2022
3No. Hager distribution boards in good order. CAT II light in good order.
B
£0
13
0
0 0
0
2022
CAT II light in good order.
C
£200
0
2
0 0
0
2009
Tungsten light requires replacement.
B(C)
£200
3
3
0 0
0
2012
Surface fluorescent light requires upgrading within the maintenance schedule.
B B
£0 £0
13 10
0 0
0 0 0 0
0 0
2022 2019
CAT II light in good order. Sockets and switches in good order.
B
£0
13
0
0 0
0
2022
CAT II light in good order.
Location: 001-04-1-023c 04 - Lighting Installation
Location: 001-04-1-023d
Location: 001-04-1-024
Location: 001-04-1-025 04 - Lighting Installation
Location: 001-04-1-026 04 - Lighting Installation
Location: 001-04-1-027 04 - Lighting Installation
Location: 001-04-1-028 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-04-1-028a 04 - Lighting Installation Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-04-1-028b 03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B
£0
13
0
0 0
0
2022
05 - Emergency Lighting
B
£0
13
0
0 0
0
2022
2No. Hager distribution boards in good order. Surface fluorescent lights in good order. Emergency light in good order.
B
£0
13
0
0 0
0
2022
CAT II light in good order.
B
£0
13
0
0 0
0
2022
CAT II light in good order.
B B
£0 £0
13 10
0 0
0 0 0 0
0 0
2022 2019
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
13 10
0 0
0 0 0 0
0 0
2022 2019
CAT II light in good order. Sockets and switches in good order.
B
£0
13
0
0 0
0
2022
CAT II light in good order.
B
£0
13
0
0 0
0
2022
Surface fluorescent light in good order.
B B
£0 £0
13 10
0 0
0 0 0 0
0 0
2022 2019
2No. CAT II lights in good order. Sockets and switches in good order.
Location: 001-04-1-029 04 - Lighting Installation
Location: 001-04-1-030 04 - Lighting Installation
Location: 001-04-1-031 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-04-1-032 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-04-1-033 04 - Lighting Installation
Location: 001-04-1-033a 04 - Lighting Installation
Location: 001-04-1-033b 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-04-1-033c Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation 05 - Emergency Lighting
B B
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£0 £0
13 13
0 0
0 0 0 0
0 0
2022 2022
CAT II light in good order. Emergency light in good order.
£0 £400
13 5
0 3
0 0 0 0
0 0
2022 2014
£0
10
0
0 0
0
2019
Distribution board in good order. 2No. CAT II lights require upgrading within the maintenance schedule. Sockets and switches in good order.
£0 £2,000
10 3
0 3
0 0 0 0
0 0
2019 2012
B
£0
10
0
0 0
0
2019
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
13
0
0 0
0
2022
04 - Lighting Installation
C
£200
0
2
0 0
0
2009
04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
13 10
0 0
0 0 0 0
0 0
2022 2019
03 - Distribution Boards
B
£0
10
0
0 0
0
2019
04 - Lighting Installation
B
£0
13
0
0 0
0
2022
Location: 001-04-1-034 03 - Distribution Boards 04 - Lighting Installation
06 - Sockets/Switches
B B(C)
B
Location: 001-04-1-036 03 - Distribution Boards 04 - Lighting Installation
06 - Sockets/Switches
B B(C)
Distribution board in good order. 10No. surface fluorescent lights require upgrading within the maintenance schedule. Sockets and switches in good order.
Location: 001-04-1-039 Surface fluorescent light in good order. 2No. emergency lights in good order.
Location: 001-04-1-040 Tungsten light requires replacement. 4No. CAT II lights in good order. Sockets and switches in good order.
Location: 001-04-1-040b
Sample College Physical Condition Survey
MK distribution board in good order. Surface fluorescent light in good order. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-04-1-040c 04 - Lighting Installation
C
£200
0
2
0 0
0
2009
Tungsten light requires replacement.
£1,200
3
3
0 0
0
2012
£0
13
0
0 0
0
2022
6No. CAT II lights require upgrading within the maintenance schedule. Emergency light in good order.
£1,200
3
3
0 0
0
2012
£0 £0
13 10
0 0
0 0 0 0
0 0
2022 2019
£2,000
5
3
0 0
0
2014
£0 £0
13 10
0 0
0 0 0 0
0 0
2022 2019
£600
3
3
0 0
0
2012
£0
13
0
0 0
0
2022
£0 £800
20 3
0 3
0 0 0 0
0 0
2029 2012
Location: 001-04-1-042 04 - Lighting Installation
B(C)
05 - Emergency Lighting
B
Location: 001-04-1-043 04 - Lighting Installation
B(C)
05 - Emergency Lighting 06 - Sockets/Switches
B B
6No. CAT II lights require upgrading within the maintenance schedule. Emergency light in good order. Sockets and switches in good order.
Location: 001-04-1-044 04 - Lighting Installation
B(C)
05 - Emergency Lighting 06 - Sockets/Switches
B B
10No. surface fluorescent lights require upgrading within the maintenance schedule. Emergency light in good order. Sockets and switches in good order.
Location: 001-04-1-044a 04 - Lighting Installation
B(C)
05 - Emergency Lighting
B
3No. CAT II lights require upgrading within the maintenance schedule. Emergency light in good order.
Location: 001-04-1-061 03 - Distribution Boards 04 - Lighting Installation
Sample College Physical Condition Survey
B B(C)
Distribution board in good order. 4No. surface fluorescent lights require upgrading within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-04-1-061a 04 - Lighting Installation
B(C)
£400
3
3
0 0
0
2012
2No. surface fluorescent lights require upgrading within the maintenance schedule.
B(C)
£1,200
3
3
0 0
0
2012
6No. surface fluorescent lights require upgrading within the maintenance schedule.
Surface fluorescent light in good order. Emergency light in good order.
Location: 001-04-1-061b 04 - Lighting Installation
Location: 001-04-1-C1 04 - Lighting Installation
B
£0
13
0
0 0
0
2022
05 - Emergency Lighting
B
£0
13
0
0 0
0
2022
04 - Lighting Installation
B
£0
13
0
0 0
0
2022
05 - Emergency Lighting
B
£0
13
0
0 0
0
2022
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
12 13
0 0
0 0 0 0
0 0
2021 2022
05 - Emergency Lighting
B
£0
13
0
0 0
0
2022
04 - Lighting Installation
B
£0
13
0
0 0
0
2022
05 - Emergency Lighting
B
£0
13
0
0 0
0
2022
B
£0
20
0
0 0
0
2029
Location: 001-04-1-C2 Surface fluorescent light in good order. Emergency light in good order.
Location: 001-04-1-C3 Down light in good order. Surface fluorescent light in good order. 2No. emergency lights in good order.
Location: 001-04-1-C4 Surface fluorescent light in good order. Emergency light in good order.
Location: 001-04-1-C5 03 - Distribution Boards
Sample College Physical Condition Survey
MEM distribution board in good order.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
04 - Lighting Installation
B
£0
13
0
0 0
0
2022
2No. surface fluorescent lights in good order. 2No. emergency lights in good order.
05 - Emergency Lighting
B
£0
13
0
0 0
0
2022
B
£0
20
0
0 0
0
2029
Distribution board in good order.
B
£0
20
0
0 0
0
2029
2No. distribution boards in good order.
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
13 14
0 0
0 0 0 0
0 0
2022 2023
05 - Emergency Lighting
B
£0
13
0
0 0
0
2022
CAT II light in good order. Surface fluorescent light in good order. Emergency light in good order.
B
£0
13
0
0 0
0
2022
2No. CAT II lights in good order.
B
£0
10
0
0 0
0
2019
2No. CAT II lights in good order.
04 - Lighting Installation
B
£0
14
0
0 0
0
2023
05 - Emergency Lighting
B
£0
13
0
0 0
0
2022
Surface fluorescent light in good order. Emergency light in good order.
04 - Lighting Installation
B
£0
14
0
0 0
0
2023
05 - Emergency Lighting
B
£0
13
0
0 0
0
2022
Surface fluorescent light in good order. Emergency light in good order.
B
£0
13
0
0 0
0
2022
CAT II light in good order.
Location: 001-04-LG- 045a 03 - Distribution Boards
Location: 001-04-LG- 060d 03 - Distribution Boards
Location: 001-04-LG-045
Location: 001-04-LG-045a 04 - Lighting Installation
Location: 001-04-LG-045b 04 - Lighting Installation
Location: 001-04-LG-045c
Location: 001-04-LG-045d
Location: 001-04-LG-046 04 - Lighting Installation Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 05 - Emergency Lighting
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
13
0
0 0
0
2022
Emergency light in good order.
B B
£0 £0
13 13
0 0
0 0 0 0
0 0
2022 2022
CAT II light in good order. Emergency light in good order.
04 - Lighting Installation
B
£0
14
0
0 0
0
2023
05 - Emergency Lighting
B
£0
14
0
0 0
0
2023
Surface fluorescent light in good order. Emergency light in good order.
04 - Lighting Installation
B
£0
14
0
0 0
0
2023
04 - Lighting Installation 05 - Emergency Lighting
B B
£0 £0
14 14
0 0
0 0 0 0
0 0
2023 2023
£400
5
3
0 0
0
2014
2No. CAT II lights require upgrading within the maintenance schedule.
B
£0
14
0
0 0
0
2023
Surface fluorescent light in good order.
B
£0
14
0
0 0
0
2023
Surface fluorescent light in good order.
B B
£0 £0
10 14
0 0
0 0 0 0
0 0
2019 2023
2No. CAT II lights in good order. Surface fluorescent light in good order.
Location: 001-04-LG-048 04 - Lighting Installation 05 - Emergency Lighting
Location: 001-04-LG-049
Location: 001-04-LG-050 Surface fluorescent light in good order. 6No. uplighters in good order. Emergency light in good order.
Location: 001-04-LG-051 04 - Lighting Installation
B(C)
Location: 001-04-LG-051a 04 - Lighting Installation
Location: 001-04-LG-051b 04 - Lighting Installation
Location: 001-04-LG-052 04 - Lighting Installation 04 - Lighting Installation
Location: 001-04-LG-052a Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
14
0
0 0
0
2023
Surface fluorescent light in good order.
B
£0
14
0
0 0
0
2023
Surface fluorescent light in good order.
04 - Lighting Installation
B
£0
14
0
0 0
0
2023
05 - Emergency Lighting
B
£0
13
0
0 0
0
2022
Surface fluorescent light in good order. Emergency light in good order.
B
£0
14
0
0 0
0
2023
Surface fluorescent light in good order.
B
£0
14
0
0 0
0
2023
Surface fluorescent light in good order.
B
£0
14
0
0 0
0
2023
Surface fluorescent light in good order.
B
£0
14
0
0 0
0
2023
Surface fluorescent light in good order.
B
£0
14
0
0 0
0
2023
Surface fluorescent light in good order.
B
£0
14
0
0 0
0
2023
Surface fluorescent light in good order.
Location: 001-04-LG-052b 04 - Lighting Installation
Location: 001-04-LG-053
Location: 001-04-LG-053a 04 - Lighting Installation
Location: 001-04-LG-053b 04 - Lighting Installation
Location: 001-04-LG-053c 04 - Lighting Installation
Location: 001-04-LG-053d 04 - Lighting Installation
Location: 001-04-LG-053e 04 - Lighting Installation
Location: 001-04-LG-054 04 - Lighting Installation
Location: 001-04-LG-055 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02 - Main Switchgear 04 - Lighting Installation
B
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£0
30
0
0 0
0
2039
Eaton William MEM switchgear in good order. 2No. surface fluorescent lights require upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
C
£400
0
2
0 0
0
2009
2No. tungsten lights require replacement.
6No. surface fluorescent lights require upgrading within the maintenance schedule. Emergency light requires upgrading within the maintenance schedule.
Location: 001-04-LG-056 04 - Lighting Installation
Location: 001-04-LG-057 04 - Lighting Installation
B(C)
£1,200
5
3
0 0
0
2014
05 - Emergency Lighting
B(C)
£200
5
3
0 0
0
2014
Location: 001-04-LG-060 04 - Lighting Installation
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order. 3No. HID lights in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
04 - Lighting Installation
B
£0
14
0
0 0
0
2023
05 - Emergency Lighting
B
£0
13
0
0 0
0
2022
B
£0
10
0
0 0
0
2019
9No. down lighters in good order.
04 - Lighting Installation
B
£0
14
0
0 0
0
2023
05 - Emergency Lighting
B
£0
13
0
0 0
0
2022
Surface fluorescent light in good order. Emergency light in good order.
Location: 001-04-LG-060a Surface fluorescent light in good order. Emergency light in good order.
Location: 001-04-LG-060b 04 - Lighting Installation
Location: 001-04-LG-060c
Location: 001-04-LG-060d Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
10
0
0 0
0
2019
2No. surface fluorescent lights in good order.
B
£0
13
0
0 0
0
2022
Fire alarm main panel in good order.
B
£0
13
0
0 0
0
2022
Smoke detector in good order.
B
£0
13
0
0 0
0
2022
Smoke detector in good order.
B
£0
13
0
0 0
0
2022
Smoke detector in good order.
B
£0
13
0
0 0
0
2022
Smoke detector in good order.
B
£0
13
0
0 0
0
2022
Smoke detector in good order.
B
£0
13
0
0 0
0
2022
4No. smoke detectors in good order.
B
£0
13
0
0 0
0
2022
Smoke detector in good order.
B
£0
13
0
0 0
0
2022
Smoke detector in good order.
B
£0
13
0
0 0
0
2022
Smoke detector in good order.
V - Engineering - Fire Alarms
Location: 001-04-1-005b 05 - Fire Main/Zone Panel
Location: 001-04-1-007 03 - Smoke Detectors
Location: 001-04-1-012c 03 - Smoke Detectors
Location: 001-04-1-014c 03 - Smoke Detectors
Location: 001-04-1-033 03 - Smoke Detectors
Location: 001-04-1-034 03 - Smoke Detectors
Location: 001-04-1-039 03 - Smoke Detectors
Location: 001-04-1-040 03 - Smoke Detectors
Location: 001-04-1-042 03 - Smoke Detectors
Location: 001-04-1-044 03 - Smoke Detectors Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-04-1-044a 03 - Smoke Detectors
B
£0
13
0
0 0
0
2022
Smoke detector in good order.
B
£0
13
0
0 0
0
2022
Smoke detector in good order.
B
£0
13
0
0 0
0
2022
Smoke detector in good order.
B
£0
13
0
0 0
0
2022
2No. smoke detectors in good order.
B
£0
13
0
0 0
0
2022
Smoke detector in good order.
B
£0
13
0
0 0
0
2022
Smoke detector in good order.
B
£0
14
0
0 0
0
2023
2No. smoke detectors in good order.
B
£0
14
0
0 0
0
2023
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
14
0
0 0
0
2023
Smoke detector in good order.
B
£0
14
0
0 0
0
2023
Smoke detector in good order.
Location: 001-04-1-C1 03 - Smoke Detectors
Location: 001-04-1-C2 03 - Smoke Detectors
Location: 001-04-1-C3 03 - Smoke Detectors
Location: 001-04-1-C4 03 - Smoke Detectors
Location: 001-04-1-C5 03 - Smoke Detectors
Location: 001-04-LG-045 03 - Smoke Detectors
Location: 001-04-LG-045a 03 - Smoke Detectors
Location: 001-04-LG-045b 03 - Smoke Detectors
Location: 001-04-LG-045d 03 - Smoke Detectors
Location: 001-04-LG-046 03 - Smoke Detectors
Location: 001-04-LG-048 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Smoke Detectors
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
14
0
0 0
0
2023
Smoke detector in good order.
B
£0
14
0
0 0
0
2023
2No. smoke detectors in good order.
B
£0
14
0
0 0
0
2023
Smoke detector in good order.
B
£0
14
0
0 0
0
2023
Smoke detector in good order.
B
£0
14
0
0 0
0
2023
Smoke detector in good order.
B
£0
14
0
0 0
0
2023
Smoke detector in good order.
B
£0
14
0
0 0
0
2023
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
14
0
0 0
0
2023
Smoke detector in good order.
01 - Sounders
B
£0
12
0
0 0
0
2021
02 - Call Points
B
£0
12
0
0 0
0
2021
Fire alarm sounders in good order. Fire alarm call points in good order.
Location: 001-04-LG-050 03 - Smoke Detectors
Location: 001-04-LG-051 03 - Smoke Detectors
Location: 001-04-LG-051b 03 - Smoke Detectors
Location: 001-04-LG-052b 03 - Smoke Detectors
Location: 001-04-LG-054 03 - Smoke Detectors
Location: 001-04-LG-056 03 - Smoke Detectors
Location: 001-04-LG-060 03 - Smoke Detectors
Location: 001-04-LG-060b 03 - Smoke Detectors
Location: Whole block
Block Total
Sample College Physical Condition Survey
£1,038,757.00
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Site : Sample College - 001 Block : Study Centre - 05 Facet: 1 - Building A - Building - Physical Structure
Location: Whole Block 01 - General Structure 02 - Foundations 03 - Ground Stability
B B B
£0 £0 £0
60 80 80
0 0 0
0 0 0 0 0 0
0 0 0
2069 2089 2089
Steel frame: Generally sound. Generally sound. Generally sound.
Aluminium - Double: Require replacing due to age and condition - located to elevation 1 - 40No. Softwood timber: Redecorate and make good located to elevation 1 - 2No. double.
B - Building - External Fabric
Location: Elevation 01 04 - Windows
B(C)
£26,000
5
2
0 0
0
2014
06 - Doors
B(C)
£600
3
3
0 0
0
2012
B(C)
£29,250
5
2
0 0
0
2014
Aluminium - Double: Require replacing due to age and condition - located to elevation 2 - 45No.
04 - Windows
B(C)
£23,400
5
2
0 0
0
2014
06 - Doors
B(C)
£300
3
3
0 0
0
2012
Aluminium - Double: Require replacing due to age and condition - located to elevation 3 - 36No. Softwood timber: Redecorate and make good located to elevation 3 - 1No. double.
Location: Elevation 02 04 - Windows
Location: Elevation 03
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: Elevation 04 04 - Windows
B(C)
£23,400
5
2
0 0
0
2014
06 - Doors
B(C)
£600
3
3
0 0
0
2012
B B B B B B B B B(C)
£0 £0 £0 £0 £0 £0 £0 £0 £3,925
40 40 40 40 10 10 10 10 3
0 0 0 0 0 0 0 0 3
0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0
2049 2049 2049 2049 2019 2019 2019 2019 2012
£0
8
0
0 0
0
2017
£780
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
£1,050
2
3
0 0
0
2011
Aluminium - Double: Require replacing due to age and condition - located to elevation 4 - 36No. Softwood timber: Redecorate and make good located to elevation 4 - 2No. double.
Location: Whole Block 01a - Masonry - Cracking 01b - Masonry - Spalling 01c - Masonry - Pointing 01d - Masonry - Finish 02a - Cladding - Attachment 02b - Cladding - Cracking 02c - Cladding - Joints 02d - Cladding - Finish 05 - Window cills 06 - Doors
B
Brickwork. Brickwork. Brickwork. Brickwork. Curtain walling. Curtain walling. Curtain walling. Curtain walling. Timber: Need to make good & redecorate. Aluminium.
C - Building - Internal Fabric
Location: 001-05-0-100 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-0-100a Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
£390
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£525
2
3
0 0
0
2011
B(C)
£390
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£525
2
3
0 0
0
2011
B(C)
£780
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£1,050
2
3
0 0
0
2011
B(C)
£780
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-0-100b 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-0-101 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-0-102 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£1,050
2
3
0 0
0
2011
Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
B(C)
£780
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£1,050
2
3
0 0
0
2011
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
B(C)
£780
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£1,050
2
3
0 0
0
2011
B(C)
£780
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
£1,050
2
3
0 0
0
2011
Location: 001-05-0-103 01 - Decorations
02 - Ceiling 03 - Floor
B
Location: 001-05-0-104 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-0-105 01 - Decorations
02 - Ceiling 03 - Floor
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-0-106 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
£780
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£1,050
2
3
0 0
0
2011
B(C)
£780
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£1,050
2
3
0 0
0
2011
B(C)
£780
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£1,050
2
3
0 0
0
2011
B(C)
£650
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-0-107 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-0-108 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-0-109 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£875
2
3
0 0
0
2011
Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
B(C)
£520
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£700
2
3
0 0
0
2011
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
B(C)
£130
2
4
0 0
0
2011
C
£100
0
3
0 0
0
2009
B(C)
£175
2
3
0 0
0
2011
B(C)
£780
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
£1,050
2
3
0 0
0
2011
Location: 001-05-0-110 01 - Decorations
02 - Ceiling 03 - Floor
B
Location: 001-05-0-110a 01 - Decorations
02 - Ceiling 03 - Floor
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-0-111 01 - Decorations
02 - Ceiling 03 - Floor
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-0-112 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Cost to B Rem Life Priority C L
R
Year
£1,690
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
£2,275
5
3
0 0
0
2014
£0
8
0
0 0
0
2017
£208
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Fixed units: Kitchen units in good condition.
Location: 001-05-0-112a 01 - Decorations
02 - Ceiling
B(C)
B
03 - Floor
B(C)
£280
5
3
0 0
0
2014
08 - Fixed Units
B(C)
£1,750
1
3
0 0
0
2010
B(C)
£1,040
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£1,400
5
3
0 0
0
2014
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Fixed units: Kitchen unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-05-0-113 01 - Decorations
02 - Ceiling 03 - Floor
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition.
Location: 001-05-0-114 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
£650
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£875
5
3
0 0
0
2014
B(C)
£520
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£700
5
3
0 0
0
2014
B(C)
£520
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£700
5
3
0 0
0
2014
B(C)
£130
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition.
Location: 001-05-0-115 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition.
Location: 001-05-0-116 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition.
Location: 001-05-0-117 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
£175
2
3
0 0
0
2011
08 - Fixed Units
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
8
0
0 0
0
2017
£260
5
4
0 0
0
2014
Notes
Remedial Action
Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition. Fixed units: Sluice in good condition.
Location: 001-05-0-118 01 - Decorations
B(C)
02 - Ceiling
B
£0
10
0
0 0
0
2019
03 - Floor
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
12
0
0 0
0
2021
£260
5
4
0 0
0
2014
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-05-0-119 01 - Decorations
B(C)
02 - Ceiling
B
£0
10
0
0 0
0
2019
03 - Floor
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
12
0
0 0
0
2021
£130
5
4
0 0
0
2014
£0
10
0
0 0
0
2019
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-05-0-120 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
03 - Floor
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
12
0
0 0
0
2021
£130
5
4
0 0
0
2014
Notes
Remedial Action
Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-05-0-121 01 - Decorations
B(C)
02 - Ceiling
B
£0
10
0
0 0
0
2019
03 - Floor
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
12
0
0 0
0
2021
£390
5
4
0 0
0
2014
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-05-0-122 01 - Decorations
B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
02 - Ceiling
B
£0
10
0
0 0
0
2019
03 - Floor
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
12
0
0 0
0
2021
B
£0
6
0
0 0
0
2015
Electrics - Fit for purpose
B
£0
6
0
0 0
0
2015
Boiler Plant - Fit for purpose
£520
2
4
0 0
0
2011
Redecoration required as part of a regular maintenance schedule.
Location: 001-05-0-123 12 - Comments
Location: 001-05-0-124 12 - Comments
Location: 001-05-1-001 01 - Decorations
Sample College Physical Condition Survey
B(C)
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02 - Ceiling 03 - Floor
B
Cost to B Rem Life Priority C L
R
Year
£0
6
0
0 0
0
2015
B(C)
£700
2
3
0 0
0
2011
B(C)
£520
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£700
2
3
0 0
0
2011
B(C)
£390
1
4
0 0
0
2010
C
£100
0
3
0 0
0
2009
B(C)
£525
2
3
0 0
0
2011
B(C)
£650
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£875
2
3
0 0
0
2011
Notes
Remedial Action
Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-1-002 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-1-004 01 - Decorations
02 - Ceiling 03 - Floor
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-1-005 01 - Decorations
02 - Ceiling 03 - Floor
Sample College Physical Condition Survey
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-05-1-006 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
£650
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£875
2
3
0 0
0
2011
B(C)
£650
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£875
2
3
0 0
0
2011
B(C)
£650
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£875
2
3
0 0
0
2011
B(C)
£650
3
4
0 0
0
2012
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-1-007 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-1-008 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-1-009 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02 - Ceiling 03 - Floor
B
Cost to B Rem Life Priority C L
R
Year
£0
6
0
0 0
0
2015
B(C)
£875
2
3
0 0
0
2011
B(C)
£910
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£1,225
2
3
0 0
0
2011
B(C)
£1,560
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£2,100
2
3
0 0
0
2011
B(C)
£520
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
£700
2
3
0 0
0
2011
Notes
Remedial Action
Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-1-010 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-1-011 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-1-012 01 - Decorations
02 - Ceiling 03 - Floor
Sample College Physical Condition Survey
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-05-1-013 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
£780
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£1,050
2
3
0 0
0
2011
B(C)
£390
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£525
2
3
0 0
0
2011
B(C)
£1,300
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-1-014 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-1-015 01 - Decorations
02 - Ceiling
B
03 - Floor
B(C)
£1,750
2
3
0 0
0
2011
08 - Fixed Units
B(C)
£1,500
2
3
0 0
0
2011
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Reception desk requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-05-1-016 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
£780
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£1,050
2
3
0 0
0
2011
B(C)
£2,600
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£3,500
2
3
0 0
0
2011
B(C)
£1,040
1
4
0 0
0
2010
B
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-1-017 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-05-1-018 01 - Decorations
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
C
£1,400
0
3
0 0
0
2009
B(C)
£2,500
1
3
0 0
0
2010
£520
0
4
0 0
0
2009
08 - Fixed Units
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet. Fixed units: Kitchen units require replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-05-1-019 01 - Decorations
Sample College Physical Condition Survey
C
Redecoration required as part of a regular maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02 - Ceiling 03 - Floor
B
Cost to B Rem Life Priority C L
R
Year
£0
6
0
0 0
0
2015
B(C)
£700
4
3
0 0
0
2013
B(C)
£520
1
4
0 0
0
2010
£0
6
0
0 0
0
2015
£700
1
3
0 0
0
2010
£0
6
0
0 0
0
2015
£390
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
£525
2
3
0 0
0
2011
£0
10
0
0 0
0
2019
£130
1
4
0 0
0
2010
£0
6
0
0 0
0
2015
Notes
Remedial Action
Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition.
Location: 001-05-1-020 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule. Fixed units: Kitchen units in good condition.
Location: 001-05-1-021 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule. Sanitary fittings: In good condition.
Location: 001-05-1-022 01 - Decorations
02 - Ceiling Sample College Physical Condition Survey
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
08 - Fixed Units
B(C)
B
Cost to B Rem Life Priority C L
R
Year
£175
4
3
0 0
0
2013
£0
10
0
0 0
0
2019
£130
1
4
0 0
0
2010
£0
6
0
0 0
0
2015
£175
4
3
0 0
0
2013
£0
10
0
0 0
0
2019
£182
1
4
0 0
0
2010
£0
8
0
0 0
0
2017
£245
4
3
0 0
0
2013
Notes
Remedial Action
Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Sanitary fittings: In good condition.
Location: 001-05-1-023 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Sanitary fittings: In good condition.
Location: 001-05-1-024 01 - Decorations
02 - Ceiling
B(C)
B
03 - Floor
B(C)
03 - Floor
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
B(C)
£78
1
4
0 0
0
2010
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Quarry tile flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-05-1-025 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02 - Ceiling 03 - Floor
B
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£0
6
0
0 0
0
2015
Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition.
B(C)
£105
4
3
0 0
0
2013
B B B B B B(C)
£0 £0 £0 £0 £0 £1,750
15 25 60 60 6 5
0 0 0 0 0 2
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
2024 2034 2069 2069 2015 2014
Metal. Mineral felt. Metal. Metal. Box gutters. Aluminium: Evidence of minor deterioration with replacement likely to be required within the maintenance period.
B B B(C)
£0 £0 £300
6 10 5
0 0 2
0 0 0 0 0 0
0 0 0
2015 2019 2014
Mineral felt with stone chippings. Plywood. Aluminium: Evidence of minor deterioration with replacement likely to be required within the maintenance period.
B B B(C)
£0 £0 £300
6 10 5
0 0 2
0 0 0 0 0 0
0 0 0
2015 2019 2014
Mineral felt with stone chippings. Plywood. Aluminium: Evidence of minor deterioration with replacement likely to be required within the maintenance period.
D - Building - Roof
Location: Roof 01 01a - Attached - Covering 01b - Attached - Sarking 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering 01h - Attached - Down Rainwater pipes
Location: Roof 02 02a - Flat - Covering 02b - Flat - Decking 02h - Flat - Down Rainwater pipes
Location: Roof 03 02a - Flat - Covering 02b - Flat - Decking 02h - Flat - Down Rainwater pipes
Facet: 2 - Engineering Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
I - Engineering - Heating Systems
Location: 001-05-0-100 01 - Heat Emitters
B
£0
15
0
0 0
0
2024
Heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
Heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
Heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
Heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
2No. heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
2No. heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
Heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
Heat emitter with low surface temperature cover in good order.
Location: 001-05-0-101 01 - Heat Emitters
Location: 001-05-0-102 01 - Heat Emitters
Location: 001-05-0-103 01 - Heat Emitters
Location: 001-05-0-104 01 - Heat Emitters
Location: 001-05-0-105 01 - Heat Emitters
Location: 001-05-0-106 01 - Heat Emitters
Location: 001-05-0-107 01 - Heat Emitters
Location: 001-05-0-108 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
15
0
0 0
0
2024
2No. heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
Heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
Heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
Heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
Heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
Heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
2No. heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
Heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
Heat emitter with low surface temperature cover in good order.
Location: 001-05-0-109 01 - Heat Emitters
Location: 001-05-0-110 01 - Heat Emitters
Location: 001-05-0-110a 01 - Heat Emitters
Location: 001-05-0-111 01 - Heat Emitters
Location: 001-05-0-112 01 - Heat Emitters
Location: 001-05-0-113 01 - Heat Emitters
Location: 001-05-0-114 01 - Heat Emitters
Location: 001-05-0-115 01 - Heat Emitters
Location: 001-05-0-116 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
15
0
0 0
0
2024
Heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
Heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
Heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
Heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
Heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
Heat emitter with low surface temperature cover in good order.
C
£250
0
2
0 0
0
2009
High efficiency convector with no low surface temperature cover requires replacement.
C
£250
0
2
0 0
0
2009
High efficiency convector with no low surface temperature cover requires replacement.
C
£250
0
2
0 0
0
2009
High efficiency convector with no low surface temperature cover requires replacement.
Location: 001-05-0-118 01 - Heat Emitters
Location: 001-05-0-119 01 - Heat Emitters
Location: 001-05-0-120 01 - Heat Emitters
Location: 001-05-0-121 01 - Heat Emitters
Location: 001-05-0-122 01 - Heat Emitters
Location: 001-05-1-001 01 - Heat Emitters
Location: 001-05-1-002 01 - Heat Emitters
Location: 001-05-1-004 01 - Heat Emitters
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-05-1-005 01 - Heat Emitters
C
£500
0
2
0 0
0
2009
2No. high efficiency convector with no low surface temperature cover requires replacement. Electric heater requires replacement.
01 - Heat Emitters
C
£300
0
2
0 0
0
2009
C
£250
0
2
0 0
0
2009
High efficiency convector with no low surface temperature cover requires replacement.
C
£500
0
2
0 0
0
2009
2No. high efficiency convector with no low surface temperature cover requires replacement.
C
£250
0
2
0 0
0
2009
High efficiency convector with no low surface temperature cover requires replacement.
01 - Heat Emitters
C
£500
0
2
0 0
0
2009
01 - Heat Emitters
C
£300
0
2
0 0
0
2009
2No. high efficiency convector with no low surface temperature cover requires replacement. Electric heater requires replacement.
C
£250
0
2
0 0
0
2009
High efficiency convector with no low surface temperature cover requires replacement.
C
£250
0
2
0 0
0
2009
High efficiency convector with no low surface temperature cover requires replacement.
Location: 001-05-1-006 01 - Heat Emitters
Location: 001-05-1-007 01 - Heat Emitters
Location: 001-05-1-008 01 - Heat Emitters
Location: 001-05-1-009
Location: 001-05-1-010 01 - Heat Emitters
Location: 001-05-1-011 01 - Heat Emitters
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-05-1-012 01 - Heat Emitters
C
£250
0
2
0 0
0
2009
High efficiency convector with no low surface temperature cover requires replacement.
C
£250
0
2
0 0
0
2009
High efficiency convector with no low surface temperature cover requires replacement.
C
£250
0
2
0 0
0
2009
High efficiency convector with no low surface temperature cover requires replacement.
C
£250
0
2
0 0
0
2009
High efficiency convector with no low surface temperature cover requires replacement.
C
£250
0
2
0 0
0
2009
High efficiency convector with no low surface temperature cover requires replacement.
C
£250
0
2
0 0
0
2009
High efficiency convector with no low surface temperature cover requires replacement.
C
£250
0
2
0 0
0
2009
High efficiency convector with no low surface temperature cover requires replacement.
Location: 001-05-1-013 01 - Heat Emitters
Location: 001-05-1-015 01 - Heat Emitters
Location: 001-05-1-016 01 - Heat Emitters
Location: 001-05-1-017 01 - Heat Emitters
Location: 001-05-1-018 01 - Heat Emitters
Location: 001-05-1-020 01 - Heat Emitters
Location: 001-05-1-021
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
C
£250
0
2
0 0
0
2009
High efficiency convector with no low surface temperature cover requires replacement.
B
£0
10
0
0 0
0
2019
Grille in good order.
B
£0
10
0
0 0
0
2019
Grille in good order.
B
£0
10
0
0 0
0
2019
Grille in good order.
B
£0
10
0
0 0
0
2019
Grille in good order.
B
£0
10
0
0 0
0
2019
Grille in good order.
B
£0
10
0
0 0
0
2019
Grille in good order.
B
£0
10
0
0 0
0
2019
Grille in good order.
B
£0
10
0
0 0
0
2019
Grille in good order.
B
£0
10
0
0 0
0
2019
Grille in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
K - Engineering - Vent & Air Con
Location: 001-05-0-118 03 - Grilles & Diffusers
Location: 001-05-0-119 03 - Grilles & Diffusers
Location: 001-05-0-120 03 - Grilles & Diffusers
Location: 001-05-0-121 03 - Grilles & Diffusers
Location: 001-05-0-122 03 - Grilles & Diffusers
Location: 001-05-1-020 03 - Grilles & Diffusers
Location: 001-05-1-023 03 - Grilles & Diffusers
Location: 001-05-1-024 03 - Grilles & Diffusers
Location: 001-05-1-025 03 - Grilles & Diffusers M - Engineering - Hot/Cold Water
Location: 001-05-0-118 03 - Blending Valves Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-05-0-119 03 - Blending Valves
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
4No. Seagold heating boilers require upgrading within the maintenance schedule. 2No. Grundfos heating twinhead pumps require upgrading within the maintenance schedule. Hertel pre-insulated cylinder requires upgrading within the maintenance schedule. 2No. Crane systems pressurisation units require upgrading within the maintenance schedule.
Location: 001-05-0-121 03 - Blending Valves
Location: 001-05-0-122 03 - Blending Valves
Location: 001-05-1-020 03 - Blending Valves
Location: 001-05-1-023 03 - Blending Valves O - Engineering - Main Plant
Location: 001-05-0-123a 01 - Heating Boilers
B(C)
£20,000
2
2
0 0
0
2011
02 - Pumps
B(C)
£3,000
2
2
0 0
0
2011
03 - Calorifiers
B(C)
£1,000
2
2
0 0
0
2011
05 - Pressurisation Units
B(C)
£5,000
2
2
0 0
0
2011
C
£2,000
0
2
0 0
0
2009
Location: 001-05-1-019 03 - Calorifiers
Calorifier requires replacement.
P - Engineering - Main Plant Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-05-0-123a 03 - Controls
B(C)
£7,500
2
2
0 0
0
2011
ASTEC Services Limited control panel requires upgrading within the maintenance schedule.
B B
£0 £0
14 14
0 0
0 0 0 0
0 0
2023 2023
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
14 14
0 0
0 0 0 0
0 0
2023 2023
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
14 14
0 0
0 0 0 0
0 0
2023 2023
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
14 14
0 0
0 0 0 0
0 0
2023 2023
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
14 14
0 0
0 0 0 0
0 0
2023 2023
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
14 14
0 0
0 0 0 0
0 0
2023 2023
CAT II light in good order. Sockets and switches in good order.
R - Engineering - Electrical
Location: 001-05-0-100 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-05-0-100a 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-05-0-100b 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-05-0-101 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-05-0-102 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-05-0-103 04 - Lighting Installation 06 - Sockets/Switches
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-05-0-104 04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
14 14
0 0
0 0 0 0
0 0
2023 2023
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
14 14
0 0
0 0 0 0
0 0
2023 2023
CAT II light in good order. Sockets and switches in good order.
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
14 14
0 0
0 0 0 0
0 0
2023 2023
Merlin Gerin distribution board in good order. CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
14 14
0 0
0 0 0 0
0 0
2023 2023
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
14 14
0 0
0 0 0 0
0 0
2023 2023
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
14 14
0 0
0 0 0 0
0 0
2023 2023
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
14 14
0 0
0 0 0 0
0 0
2023 2023
CAT II light in good order. Sockets and switches in good order.
Location: 001-05-0-105 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-05-0-106
Location: 001-05-0-107 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-05-0-108 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-05-0-109 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-05-0-110 04 - Lighting Installation 06 - Sockets/Switches
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-05-0-110a 04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
14 14
0 0
0 0 0 0
0 0
2023 2023
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
14 14
0 0
0 0 0 0
0 0
2023 2023
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
14 15
0 0
0 0 0 0
0 0
2023 2024
CAT II light in good order. Emergency light in good order.
B B
£0 £0
14 15
0 0
0 0 0 0
0 0
2023 2024
CAT II light in good order. Emergency light in good order.
B B
£0 £0
14 15
0 0
0 0 0 0
0 0
2023 2024
CAT II light in good order. Emergency light in good order.
B
£0
14
0
0 0
0
2023
CAT II light in good order.
04 - Lighting Installation
B
£0
14
0
0 0
0
2023
04 - Lighting Installation
B
£0
14
0
0 0
0
2023
Surface fluorescent light in good order. CAT II light in good order.
B
£0
14
0
0 0
0
2023
Location: 001-05-0-111 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-05-0-112 04 - Lighting Installation 05 - Emergency Lighting
Location: 001-05-0-113 04 - Lighting Installation 05 - Emergency Lighting
Location: 001-05-0-114 04 - Lighting Installation 05 - Emergency Lighting
Location: 001-05-0-115 04 - Lighting Installation
Location: 001-05-0-116
Location: 001-05-0-117 04 - Lighting Installation
Surface fluorescent light in good order.
Location: 001-05-0-118 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
14
0
0 0
0
2023
Surface fluorescent light in good order.
B
£0
14
0
0 0
0
2023
Surface fluorescent light in good order.
04 - Lighting Installation
B
£0
14
0
0 0
0
2023
05 - Emergency Lighting
B
£0
15
0
0 0
0
2024
Surface fluorescent light in good order. Emergency light in good order.
B
£0
14
0
0 0
0
2023
Surface fluorescent light in good order.
B
£0
14
0
0 0
0
2023
2No. surface fluorescent lights in good order.
01 - Incoming Cable 02 - Main Switchgear
B B
£0 £0
15 15
0 0
0 0 0 0
0 0
2024 2024
03 - Distribution Boards
B
£0
15
0
0 0
0
2024
03 - Distribution Boards
B
£0
15
0
0 0
0
2024
Incoming cable in good order. 2No. compartmentalised switchgear in good order. Square D distribution board in good order. Load Centre Square D distribution board in good order.
£800
2
2
0 0
0
2011
4No. surface fluorescent lights require upgrading within the maintenance schedule.
£0
14
0
0 0
0
2023
CAT II light in good order.
Location: 001-05-0-119 04 - Lighting Installation
Location: 001-05-0-120
Location: 001-05-0-121 04 - Lighting Installation
Location: 001-05-0-122 04 - Lighting Installation
Location: 001-05-0-123
Location: 001-05-0-123a 04 - Lighting Installation
B(C)
Location: 001-05-1-001 04 - Lighting Installation
Sample College Physical Condition Survey
B
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 06 - Sockets/Switches
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
15
0
0 0
0
2024
Sockets and switches in good order.
B B
£0 £0
14 15
0 0
0 0 0 0
0 0
2023 2024
CAT II light in good order. Sockets and switches in good order.
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B
£0
14
0
0 0
0
2023
2No. Square D distribution boards in good order. 2No. surface fluorescent lights in good order.
B B
£0 £0
14 15
0 0
0 0 0 0
0 0
2023 2024
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
14 15
0 0
0 0 0 0
0 0
2023 2024
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
14 15
0 0
0 0 0 0
0 0
2023 2024
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
14 15
0 0
0 0 0 0
0 0
2023 2024
CAT II light in good order. Sockets and switches in good order.
B
£0
14
0
0 0
0
2023
CAT II light in good order.
Location: 001-05-1-002 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-05-1-004
Location: 001-05-1-005 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-05-1-006 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-05-1-007 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-05-1-008 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-05-1-009 04 - Lighting Installation Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 06 - Sockets/Switches
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
15
0
0 0
0
2024
Sockets and switches in good order.
B B
£0 £0
14 15
0 0
0 0 0 0
0 0
2023 2024
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
14 15
0 0
0 0 0 0
0 0
2023 2024
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
14 15
0 0
0 0 0 0
0 0
2023 2024
CAT II light in good order. Sockets and switches in good order.
B B B
£0 £0 £0
14 12 15
0 0 0
0 0 0 0 0 0
0 0 0
2023 2021 2024
CAT II light in good order. Emergency light in good order. Sockets and switches in good order.
04 - Lighting Installation
B
£0
14
0
0 0
0
2023
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order. Emergency light in good order.
B B B
£0 £0 £0
14 12 15
0 0 0
0 0 0 0 0 0
0 0 0
2023 2021 2024
Location: 001-05-1-010 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-05-1-011 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-05-1-012 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-05-1-013 04 - Lighting Installation 05 - Emergency Lighting 06 - Sockets/Switches
Location: 001-05-1-014
Location: 001-05-1-015 04 - Lighting Installation 05 - Emergency Lighting 06 - Sockets/Switches
CAT II light in good order. Emergency light in good order. Sockets and switches in good order.
Location: 001-05-1-016 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
14
0
0 0
0
2023
CAT II light in good order.
B B B
£0 £0 £0
14 12 15
0 0 0
0 0 0 0 0 0
0 0 0
2023 2021 2024
CAT II light in good order. Emergency light in good order. Sockets and switches in good order.
B
£0
14
0
0 0
0
2023
CAT II light in good order.
B
£0
14
0
0 0
0
2023
2No. surface fluorescent light in good order.
B B
£0 £0
14 12
0 0
0 0 0 0
0 0
2023 2021
CAT II light in good order. Emergency light in good order.
04 - Lighting Installation
B
£0
14
0
0 0
0
2023
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order. Emergency light in good order.
04 - Lighting Installation
B
£0
14
0
0 0
0
2023
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
B
£0
14
0
0 0
0
2023
Surface fluorescent light in good order.
B
£0
14
0
0 0
0
2023
Surface fluorescent light in good order.
Location: 001-05-1-017 04 - Lighting Installation 05 - Emergency Lighting 06 - Sockets/Switches
Location: 001-05-1-018 04 - Lighting Installation
Location: 001-05-1-019 04 - Lighting Installation
Location: 001-05-1-020 04 - Lighting Installation 05 - Emergency Lighting
Location: 001-05-1-021
Location: 001-05-1-022 Surface fluorescent light in good order. Emergency light in good order.
Location: 001-05-1-023 04 - Lighting Installation
Location: 001-05-1-024 04 - Lighting Installation
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 05 - Emergency Lighting
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
12
0
0 0
0
2021
Emergency light in good order.
B
£0
14
0
0 0
0
2023
Surface fluorescent light in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Fire alarm main panel in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
Sounders in good order. Call points in good order.
Location: 001-05-1-025 04 - Lighting Installation V - Engineering - Fire Alarms
Location: 001-05-1-011 03 - Smoke Detectors
Location: 001-05-1-013 03 - Smoke Detectors
Location: 001-05-1-014 05 - Fire Main/Zone Panel
Location: 001-05-1-016 03 - Smoke Detectors
Location: 001-05-1-018 03 - Smoke Detectors
Location: Whole Block 01 - Sounders 02 - Call Points Block Total
Sample College Physical Condition Survey
£235,173.00
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Site : Sample College - 001 Block : B Hostel - 06 Facet: 1 - Building A - Building - Physical Structure
Location: Whole Block 01 - General Structure 02 - Foundations 03 - Ground Stability
B B B
£0 £0 £0
40 60 60
0 0 0
0 0 0 0 0 0
0 0 0
2049 2069 2069
Brickwork: Generally sound. Generally sound. Generally sound.
04 - Windows
C
£4,500
0
1
0 0
0
2009
04 - Windows
B(C)
£2,300
1
2
0 0
0
2010
06 - Doors
B(C)
£1,000
4
3
0 0
0
2013
Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 1 - 10No. Softwood timber - Single: Require replacement - located to elevation 1 - 2No. Softwood timber: Redecorate and make good - located to elevation 1 - 5No. single.
B - Building - External Fabric
Location: Elevation 01
Location: Elevation 02 02a - Cladding - Attachment
C
£200
0
1
0 0
0
2009
04 - Windows
C
£3,150
0
1
0 0
0
2009
Zinc sheet: Section has come away with making good required - located to elevation 2. Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 2 - 7No.
Location: Elevation 03
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Windows
06 - Doors
C
B(C)
Cost to B Rem Life Priority C L
R
Year
£4,950
0
1
0 0
0
2009
£900
4
3
0 0
0
2013
Notes
Remedial Action
Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 3 - 11No. Softwood timber: Redecorate and make good - located to elevation 3 - 3No. single & 1No. double.
Location: Elevation 04 02a - Cladding - Attachment
B
£0
10
0
0 0
0
2019
02b - Cladding - Cracking
B
£0
10
0
0 0
0
2019
02c - Cladding - Joints
B
£0
10
0
0 0
0
2019
02d - Cladding - Finish
B
£0
10
0
0 0
0
2019
02a - Cladding - Attachment
B
£0
8
0
0 0
0
2017
02b - Cladding - Cracking
B
£0
8
0
0 0
0
2017
02c - Cladding - Joints
B
£0
8
0
0 0
0
2017
02d - Cladding - Finish
B
£0
8
0
0 0
0
2017
Plastic profiled sheet cladding: Located to elevation 4 (extension). Plastic profiled sheet cladding: Located to elevation 4 (extension). Plastic profiled sheet cladding: Located to elevation 4 (extension). Plastic profiled sheet cladding: Located to elevation 4 (extension).
Location: Elevation 05
Sample College Physical Condition Survey
Plastic profiled sheet cladding: Located to elevation 5 (two storey section). Plastic profiled sheet cladding: Located to elevation 5 (two storey section). Plastic profiled sheet cladding: Located to elevation 5 (two storey section). Plastic profiled sheet cladding: Located to elevation 5 (two storey section).
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
04 - Windows
C
£5,850
0
1
0 0
0
2009
06 - Doors
C
£1,250
0
1
0 0
0
2009
04 - Windows
C
£5,400
0
1
0 0
0
2009
04 - Windows
B(C)
£1,150
1
2
0 0
0
2010
06 - Doors
B(C)
£600
4
3
0 0
0
2013
Notes
Remedial Action
Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 5 - 13No. Steel: Need to replace located to elevation 5 - 1No. single.
Location: Elevation 06 Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 6 - 12No. Softwood timber - Single: Require replacement - located to elevation 6 - 1No. Softwood timber: Redecorate and make good - located to elevation 6 - 3No. single.
Location: Whole Block 01a - Masonry - Cracking 01b - Masonry - Spalling 01c - Masonry - Pointing 01d - Masonry - Finish 02b - Cladding - Cracking
B B B B B
£0 £0 £0 £0 £0
20 20 20 20 6
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
2029 2029 2029 2029 2015
Brickwork. Brickwork. Brickwork. Brickwork. Zinc sheet.
02c - Cladding - Joints 02d - Cladding - Finish 04 - Windows 06 - Doors
B B B B
£0 £0 £0 £0
6 6 6 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2015 2015 2015
Zinc sheet. Zinc sheet. Aluminium - Double. Aluminium.
C - Building - Internal Fabric Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-06-0-001 01 - Decorations
02 - Ceiling
B(C)
B
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
03 - Floor
B(C)
£350
2
3
0 0
0
2011
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£312
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-06-0-002 01 - Decorations
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
10
0
0 0
0
2019
08 - Fixed Units
B
£0
6
0
0 0
0
2015
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£350
2
3
0 0
0
2011
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-06-0-003 01 - Decorations
02 - Ceiling 03 - Floor
Sample College Physical Condition Survey
B(C)
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 08 - Fixed Units
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£1,250
1
2
0 0
0
2010
Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
B(C)
£208
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-06-0-004 01 - Decorations
02 - Ceiling
B
03 - Floor
B(C)
£280
2
3
0 0
0
2011
08 - Fixed Units
B(C)
£1,250
2
2
0 0
0
2011
B(C)
£208
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
£280
4
3
0 0
0
2013
£0
8
0
0 0
0
2017
£520
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
Location: 001-06-0-004a 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit - In Good Condition
Location: 001-06-0-004b 01 - Decorations
02 - Ceiling Sample College Physical Condition Survey
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
08 - Fixed Units
B(C)
B
Cost to B Rem Life Priority C L
R
Year
£700
4
3
0 0
0
2013
£0
8
0
0 0
0
2017
£208
3
4
0 0
0
2012
Notes
Remedial Action
Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit - In Good Condition
Location: 001-06-0-005 01 - Decorations
B(C)
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
£260
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition.
Location: 001-06-0-006 01 - Decorations
B(C)
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
10
0
0 0
0
2019
08 - Fixed Units
B
£0
6
0
0 0
0
2015
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-06-0-007 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
08 - Fixed Units
B(C)
B
Cost to B Rem Life Priority C L
R
Year
£350
3
3
0 0
0
2012
£0
6
0
0 0
0
2015
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
Notes
Remedial Action
Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-06-0-008 01 - Decorations
02 - Ceiling
B(C)
B
03 - Floor
B(C)
£350
2
3
0 0
0
2011
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-06-0-009 01 - Decorations
02 - Ceiling
B
03 - Floor
B(C)
£350
2
3
0 0
0
2011
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-06-0-010 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling
B(C)
B
Cost to B Rem Life Priority C L
R
Year
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
03 - Floor
B(C)
£350
2
3
0 0
0
2011
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-06-0-015 01 - Decorations
02 - Ceiling
B
03 - Floor
B(C)
£350
2
3
0 0
0
2011
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£350
2
3
0 0
0
2011
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-06-0-016 01 - Decorations
02 - Ceiling 03 - Floor
Sample College Physical Condition Survey
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 08 - Fixed Units
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£1,250
1
2
0 0
0
2010
Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
B(C)
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-06-0-017 01 - Decorations
02 - Ceiling
B
03 - Floor
B(C)
£350
2
3
0 0
0
2011
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£350
3
3
0 0
0
2012
£0
6
0
0 0
0
2015
£260
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
Location: 001-06-0-018 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-06-0-019 01 - Decorations
02 - Ceiling Sample College Physical Condition Survey
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
£130
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£175
2
3
0 0
0
2011
B(C)
£442
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£595
3
3
0 0
0
2012
£0
6
0
0 0
0
2015
£312
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£420
3
3
0 0
0
2012
Notes
Remedial Action
Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition.
Location: 001-06-0-020 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-021 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-06-0-022 01 - Decorations
02 - Ceiling 03 - Floor
Sample College Physical Condition Survey
B(C)
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 08 - Fixed Units
B
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£0
6
0
0 0
0
2015
Fixed units: Sink unit in good condition.
£312
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£420
3
3
0 0
0
2012
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
£208
3
4
0 0
0
2012
Location: 001-06-0-023 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Location: 001-06-0-024 01 - Decorations
B(C)
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
10
0
0 0
0
2019
08 - Fixed Units
B
£0
6
0
0 0
0
2015
B(C)
£442
3
4
0 0
0
2012
02 - Ceiling
C
£100
0
3
0 0
0
2009
03 - Floor
B
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-06-0-025 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Anti-slip vinyl sheet flooring: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
05 - Condition of Internal Walls
B
£0
10
0
0 0
0
2019
08 - Fixed Units
B
£0
6
0
0 0
0
2015
£130
3
4
0 0
0
2012
Notes
Remedial Action
Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-06-0-026 01 - Decorations
B(C)
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
01 - Decorations
B(C)
£78
3
4
0 0
0
2012
02 - Ceiling 03 - Floor
B B(C)
£0 £105
10 2
0 3
0 0 0 0
0 0
2019 2011
B(C)
£104
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition.
Location: 001-06-0-027 Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-035 01 - Decorations
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Fixed units: Sink unit in good condition.
Location: 001-06-0-036
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
B(C)
Cost to B Rem Life Priority C L
R
Year
£182
3
4
0 0
0
2012
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
8
0
0 0
0
2017
£260
3
4
0 0
0
2012
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition.
Location: 001-06-0-037 01 - Decorations
B(C)
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£312
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£420
3
3
0 0
0
2012
£0
6
0
0 0
0
2015
£312
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-06-0-038 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-06-0-039 01 - Decorations
Sample College Physical Condition Survey
B(C)
Redecoration required as part of a regular maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
6
0
0 0
0
2015
£442
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£595
3
3
0 0
0
2012
£0
6
0
0 0
0
2015
£208
3
4
0 0
0
2012
Notes
Remedial Action
Suspended ceiling: In good condition. Vinyl sheet flooring: In good condition. Fixed units: Sink unit in good condition.
Location: 001-06-0-040 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-06-0-041 01 - Decorations
B(C)
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
8
0
0 0
0
2017
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition.
Location: 001-06-0-042 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
08 - Fixed Units
B(C)
B
Cost to B Rem Life Priority C L
R
Year
£350
3
3
0 0
0
2012
£0
6
0
0 0
0
2015
£260
3
4
0 0
0
2012
Notes
Remedial Action
Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-06-0-043 01 - Decorations
B(C)
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
B(C)
£10,000
1
2
0 0
0
2010
B(C)
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
08 - Fixed Units
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: Require replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-06-0-044 01 - Decorations
02 - Ceiling
B
03 - Floor
B(C)
£350
2
3
0 0
0
2011
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£260
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-06-0-045 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02 - Ceiling
B
Cost to B Rem Life Priority C L
R
Year
£0
6
0
0 0
0
2015
Notes
Remedial Action
Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
03 - Floor
B(C)
£350
2
3
0 0
0
2011
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
N/A
£0
0
0
0 0
0
2009
No Access
B(C)
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-06-0-046 12 - Comments
Location: 001-06-0-047 01 - Decorations
02 - Ceiling
B
03 - Floor
B(C)
£350
2
3
0 0
0
2011
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£468
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£630
3
3
0 0
0
2012
Location: 001-06-0-048 01 - Decorations
02 - Ceiling 03 - Floor
Sample College Physical Condition Survey
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 08 - Fixed Units
B
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£0
6
0
0 0
0
2015
Fixed units: Sink unit in good condition.
£468
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£630
3
3
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£78
3
4
0 0
0
2012
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£350
2
3
0 0
0
2011
Location: 001-06-0-050 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Location: 001-06-0-050a 01 - Decorations
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-06-0-051 01 - Decorations
02 - Ceiling 03 - Floor
Sample College Physical Condition Survey
B(C)
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 08 - Fixed Units
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£1,250
1
2
0 0
0
2010
Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
B(C)
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-06-0-052 01 - Decorations
02 - Ceiling
B
03 - Floor
B(C)
£350
2
3
0 0
0
2011
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
Location: 001-06-0-053 01 - Decorations
02 - Ceiling
B
03 - Floor
B(C)
£350
2
3
0 0
0
2011
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£260
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-06-0-054 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02 - Ceiling 03 - Floor
08 - Fixed Units
B B(C)
B
Cost to B Rem Life Priority C L
R
Year
£0
6
0
0 0
0
2015
£350
3
3
0 0
0
2012
£0
6
0
0 0
0
2015
£260
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
£350
1
3
0 0
0
2010
£0
6
0
0 0
0
2015
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
Notes
Remedial Action
Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-06-0-055 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-06-0-056 01 - Decorations
02 - Ceiling
B(C)
B
03 - Floor
B(C)
£350
2
3
0 0
0
2011
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-06-0-057 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
B(C)
Cost to B Rem Life Priority C L
R
Year
£260
3
4
0 0
0
2012
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-06-0-058 01 - Decorations
02 - Ceiling
B(C)
B
03 - Floor
B(C)
£350
2
3
0 0
0
2011
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£130
1
4
0 0
0
2010
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-06-0-059 01 - Decorations
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 08 - Fixed Units
B(C)
08 - Fixed Units
B
Cost to B Rem Life Priority C L
R
Year
£1,750
2
2
0 0
0
2011
£0
6
0
0 0
0
2015
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
Notes
Remedial Action
Fixed units: Fitted unit requires replacement within the maintenance schedule due to age and level of deterioration. Fixed units: Sluice in good condition.
Location: 001-06-0-060 01 - Decorations
02 - Ceiling
B(C)
B
03 - Floor
B(C)
£350
2
3
0 0
0
2011
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£130
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-06-0-061 01 - Decorations
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
£390
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition.
Location: 001-06-0-062 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£525
1
3
0 0
0
2010
Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£312
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£420
1
3
0 0
0
2010
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£260
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£350
1
3
0 0
0
2010
B(C)
£312
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
£420
1
3
0 0
0
2010
Location: 001-06-0-063 01 - Decorations
02 - Ceiling 03 - Floor
B
Location: 001-06-0-064 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-065 01 - Decorations
02 - Ceiling 03 - Floor
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-066 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
£260
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£350
1
3
0 0
0
2010
B(C)
£104
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£140
2
3
0 0
0
2011
B(C)
£156
3
4
0 0
0
2012
B
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-067 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-068 01 - Decorations
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
B(C)
£10,000
1
2
0 0
0
2010
B(C)
£312
3
4
0 0
0
2012
08 - Fixed Units
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: Require replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-06-0-069 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02 - Ceiling 03 - Floor
B
Cost to B Rem Life Priority C L
R
Year
£0
6
0
0 0
0
2015
B(C)
£420
2
3
0 0
0
2011
B(C)
£390
3
4
0 0
0
2012
Notes
Remedial Action
Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-070 01 - Decorations
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
£156
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition.
Location: 001-06-0-071 01 - Decorations
B(C)
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
8
0
0 0
0
2017
£312
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
£420
1
3
0 0
0
2010
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Fixed units: Kitchen units in good condition.
Location: 001-06-0-072 01 - Decorations
02 - Ceiling 03 - Floor
Sample College Physical Condition Survey
B(C)
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-06-0-073 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
£442
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£595
1
3
0 0
0
2010
B(C)
£208
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£280
1
3
0 0
0
2010
B(C)
£312
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£420
1
3
0 0
0
2010
B(C)
£1,300
4
4
0 0
0
2013
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-074 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-075 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-076 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02 - Ceiling 03 - Floor
B
Cost to B Rem Life Priority C L
R
Year
£0
15
0
0 0
0
2024
B(C)
£1,750
3
3
0 0
0
2012
B(C)
£312
3
4
0 0
0
2012
Notes
Remedial Action
Timber panelling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-077 01 - Decorations
02 - Ceiling
B
£0
20
0
0 0
0
2029
03 - Floor
B
£0
10
0
0 0
0
2019
08 - Fixed Units
B
£0
20
0
0 0
0
2029
B(C)
£52
4
4
0 0
0
2013
02 - Ceiling
B
£0
20
0
0 0
0
2029
03 - Floor
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£260
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Vinyl sheet flooring: In good condition. Fixed units: Kitchen units in good condition.
Location: 001-06-0-078 01 - Decorations
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-06-0-079 01 - Decorations
B(C)
02 - Ceiling 03 - Floor
B B
£0 £0
10 6
0 0
0 0 0 0
0 0
2019 2015
08 - Fixed Units
B
£0
8
0
0 0
0
2017
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Fixed units: Kitchen units in good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-06-0-080 01 - Decorations
B(C)
£468
3
4
0 0
0
2012
02 - Ceiling 03 - Floor
B B(C)
£0 £630
10 2
0 3
0 0 0 0
0 0
2019 2011
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
£0
6
0
0 0
0
2015
Cupboard fit for purpose.
£390
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£525
1
3
0 0
0
2010
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£1,170
4
4
0 0
0
2013
Location: 001-06-0-081 12 - Comments
B
Location: 001-06-0-082 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Location: 001-06-0-083 01 - Decorations
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
8
0
0 0
0
2017
£390
2
4
0 0
0
2011
Redecoration required as part of a regular maintenance schedule. Timber panelling: In good condition. Anti-slip vinyl sheet flooring: In good condition.
Location: 001-06-0-084 01 - Decorations
Sample College Physical Condition Survey
B(C)
Redecoration required as part of a regular maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02 - Ceiling 03 - Floor
B
Cost to B Rem Life Priority C L
R
Year
£0
6
0
0 0
0
2015
B(C)
£525
1
3
0 0
0
2010
B(C)
£312
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£420
1
3
0 0
0
2010
B(C)
£260
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£350
1
3
0 0
0
2010
B(C)
£312
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
£420
1
3
0 0
0
2010
Notes
Remedial Action
Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-085 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-086 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-087 01 - Decorations
02 - Ceiling 03 - Floor
Sample College Physical Condition Survey
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-06-0-088 01 - Decorations
02 - Ceiling
B(C)
C
£1,170
2
4
0 0
0
2011
£150
0
3
0 0
0
2009
£1,575
2
3
0 0
0
2011
03 - Floor
B(C)
03 - Floor
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
8
0
0 0
0
2017
£312
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
B(C)
£420
1
3
0 0
0
2010
B(C)
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
£350
2
3
0 0
0
2011
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Anti-slip vinyl sheet flooring: In good condition. Fixed units: Kitchen units in good condition.
Location: 001-06-0-089 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-101 01 - Decorations
02 - Ceiling 03 - Floor
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-102 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
B(C)
Cost to B Rem Life Priority C L
R
Year
£104
3
4
0 0
0
2012
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
B(C)
£350
2
3
0 0
0
2011
B(C)
£104
3
4
0 0
0
2012
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-06-0-103 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-104 01 - Decorations
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-06-0-105
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
B(C)
£350
2
3
0 0
0
2011
B(C)
£104
3
4
0 0
0
2012
B
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-106 01 - Decorations
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
B(C)
£350
2
3
0 0
0
2011
B(C)
£104
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-06-0-107 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-108 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
B(C)
£350
2
3
0 0
0
2011
B(C)
£104
3
4
0 0
0
2012
Notes
Remedial Action
Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-06-0-109 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-110 01 - Decorations
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£260
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-06-0-111 01 - Decorations
Sample College Physical Condition Survey
B(C)
Redecoration required as part of a regular maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
B(C)
£350
2
3
0 0
0
2011
B(C)
£104
3
4
0 0
0
2012
Notes
Remedial Action
Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-06-0-112 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-113 01 - Decorations
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£130
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-06-0-114 01 - Decorations
Sample College Physical Condition Survey
B(C)
Redecoration required as part of a regular maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
B(C)
£350
2
3
0 0
0
2011
B(C)
£104
3
4
0 0
0
2012
Notes
Remedial Action
Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-06-0-115 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-116 01 - Decorations
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£260
4
4
0 0
0
2013
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-06-0-117 01 - Decorations
Sample College Physical Condition Survey
B(C)
Redecoration required as part of a regular maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02 - Ceiling 03 - Floor
B
Cost to B Rem Life Priority C L
R
Year
£0
6
0
0 0
0
2015
B(C)
£350
2
3
0 0
0
2011
B(C)
£104
3
4
0 0
0
2012
Notes
Remedial Action
Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-118 01 - Decorations
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
B(C)
£52
3
4
0 0
0
2012
B
£0
6
0
0 0
0
2015
B(C)
£70
2
3
0 0
0
2011
B(C)
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-06-0-119 01 - Decorations
02 - Ceiling 03 - Floor
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-0-120 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£350
2
3
0 0
0
2011
Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£104
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-06-0-121 01 - Decorations
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£130
3
4
0 0
0
2012
Location: 001-06-0-122 01 - Decorations
B(C)
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-06-0-123 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£350
2
3
0 0
0
2011
Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
C
£100
0
3
0 0
0
2009
B(C)
£350
2
3
0 0
0
2011
B
£0
20
0
0 0
0
2029
Suspended ceiling: Replace water damaged tiles. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fairfaced brickwork: In good condition.
B(C)
£78
2
4
0 0
0
2011
02 - Ceiling
C
£150
0
2
0 0
0
2009
03 - Floor
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
Location: 001-06-0-124 02 - Ceiling 03 - Floor
05 - Condition of Internal Walls
Location: 001-06-1-001 01 - Decorations
Redecoration required as part of a regular maintenance schedule. Artex ceiling: Make good and redecorate water ingress to Artex ceiling. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-06-1-002 01 - Decorations
B(C)
£260
4
4
0 0
0
2013
02 - Ceiling 03 - Floor
B B(C)
£0 £350
10 2
0 3
0 0 0 0
0 0
2019 2011
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-1-003 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
01 - Decorations
B(C)
£390
4
4
0 0
0
2013
02 - Ceiling 03 - Floor
B B(C)
£0 £525
10 2
0 3
0 0 0 0
0 0
2019 2011
01 - Decorations
B(C)
£208
4
4
0 0
0
2013
02 - Ceiling 03 - Floor
B B(C)
£0 £280
10 2
0 3
0 0 0 0
0 0
2019 2011
B(C)
£650
2
4
0 0
0
2011
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-1-004 Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-LG-001 01 - Decorations
02 - Ceiling
B
£0
20
0
0 0
0
2029
03 - Floor
B
£0
8
0
0 0
0
2017
B(C)
£4,000
4
2
0 0
0
2013
B(C)
£650
4
4
0 0
0
2013
£0
20
0
0 0
0
2029
08 - Fixed Units
Laundry: Redecoration required as part of a regular maintenance schedule. Laundry: Plaster ceiling: In good condition. Laundry: Anti-slip vinyl sheet flooring: In good condition. Laundry: Fixed units: Laundry units require replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-06-LG-002 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Laundry: Redecoration required as part of a regular maintenance schedule. Laundry: Plaster ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
03 - Floor
B
£0
8
0
0 0
0
2017
05 - Condition of Internal Walls
C
£250
0
2
0 0
0
2009
B(C)
£650
4
4
0 0
0
2013
Notes
Remedial Action
Laundry: Anti-slip vinyl sheet flooring: In good condition. Laundry: Plaster wall: Make good and redecorate plaster walls.
Location: 001-06-LG-003 01 - Decorations
02 - Ceiling
B
£0
20
0
0 0
0
2029
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
8
0
0 0
0
2017
02 - Ceiling
B
£0
20
0
0 0
0
2029
03 - Floor
B
£0
8
0
0 0
0
2017
05 - Condition of Internal Walls
B
£0
10
0
0 0
0
2019
Laundry: Redecoration required as part of a regular maintenance schedule. Laundry: Plaster ceiling: In good condition. Laundry: Anti-slip vinyl sheet flooring: In good condition. Laundry: Fixed units: Belfast sink unit in good condition. Laundry: Fixed units: Sink unit in good condition.
Location: 001-06-LG-004 Laundry: Plaster ceiling: In good condition. Laundry: Anti-slip vinyl sheet flooring: In good condition. Laundry: Plastic walls: In good condition.
Location: 001-06-LG-005 01 - Decorations
B(C)
£260
2
4
0 0
0
2011
02 - Ceiling
B(C)
£1,200
2
2
0 0
0
2011
03 - Floor
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
Sample College Physical Condition Survey
Laundry: Redecoration required as part of a regular maintenance schedule. Laundry: Suspended ceiling: Requires replacement within the maintenance schedule. Laundry: Anti-slip vinyl sheet flooring: In good condition. Laundry: Sanitary fittings: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-06-LG-006 01 - Decorations
B(C)
£130
1
4
0 0
0
2010
02 - Ceiling
B(C)
£600
2
2
0 0
0
2011
03 - Floor
B(C)
£175
1
3
0 0
0
2010
C
£312
0
4
0 0
0
2009
Bursar's Room's: Redecoration required as part of a regular maintenance schedule. Bursar's Room's: Suspended ceiling: Requires replacement within the maintenance schedule. Bursar's Room's: Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-06-LG-007 01 - Decorations
02 - Ceiling
B(C)
£1,440
2
2
0 0
0
2011
03 - Floor
B(C)
£420
1
3
0 0
0
2010
£2,500
0
2
0 0
0
2009
08 - Fixed Units
C
Bursar's Room's: Redecoration required as part of a regular maintenance schedule. Bursar's Room's: Suspended ceiling: Requires replacement within the maintenance schedule. Bursar's Room's: Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Bursar's Room's: Fixed units: Kitchen units require replacement due to age and level of deterioration.
Location: 001-06-LG-008 01 - Decorations
B(C)
£312
1
4
0 0
0
2010
02 - Ceiling
B(C)
£1,440
2
2
0 0
0
2011
Sample College Physical Condition Survey
Bursar's Room's: Redecoration required as part of a regular maintenance schedule. Bursar's Room's: Suspended ceiling: Requires replacement within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£420
1
3
0 0
0
2010
Bursar's Room's: Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B B B(C)
£0 £0 £500
10 20 2
0 0 3
0 0 0 0 0 0
0 0 0
2019 2029 2011
B
£0
60
0
0 0
0
2069
Metal sheet. Metal sheet. Painted timber: Require redecoration. Metal.
B B B
£0 £0 £0
60 8 8
0 0 0
0 0 0 0 0 0
0 0 0
2069 2017 2017
Timber. Box gutters - Metal. PVCU.
B B B B
£0 £0 £0 £0
6 6 10 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2015 2019 2015
B B B
£0 £0 £0
20 20 6
0 0 0
0 0 0 0 0 0
0 0 0
2029 2029 2015
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. Aluminium framed glazed skylights.
B B
£0 £0
6 8
0 0
0 0 0 0
0 0
2015 2017
D - Building - Roof
Location: Roof 01 01a - Attached - Covering 01b - Attached - Sarking 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters
01f - Attached - Purlins 01g - Attached - Guttering 01g - Attached - Guttering
Location: Roof 02 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01i - Attached - Skylights
Location: Roof 03 01a - Attached - Covering 01b - Attached - Sarking Sample College Physical Condition Survey
Concrete tiles. Mineral felt. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
01h - Attached - Down Rainwater pipes
Cost to B Rem Life Priority C L
R
Year
B B
£0 £0
15 6
0 0
0 0 0 0
0 0
2024 2015
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
B
£0
6
0
0 0
0
2015
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
B
£0
6
0
0 0
0
2015
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
B B
£0 £0
20 20
0 0
0 0 0 0
0 0
2029 2029
Notes
Remedial Action
Lead. Metal sheet coping to brick parapets. Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
Location: Roof 04 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
01h - Attached - Down Rainwater pipes
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
Location: Roof 05 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins Sample College Physical Condition Survey
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
01g - Attached - Guttering
C
£1,000
0
2
0 0
0
2009
01h - Attached - Down Rainwater pipes
B
£0
6
0
0 0
0
2015
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
B
£0
6
0
0 0
0
2015
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
Notes
Remedial Action
Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
Location: Roof 06 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
01h - Attached - Down Rainwater pipes
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
Location: Roof 07 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
Sample College Physical Condition Survey
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01h - Attached - Down Rainwater pipes
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
6
0
0 0
0
2015
PVCU - Internal.
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
B
£0
6
0
0 0
0
2015
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
B
£0
6
0
0 0
0
2015
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
B
£0
6
0
0 0
0
2015
Concrete tiles.
Location: Roof 08 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
01h - Attached - Down Rainwater pipes
Location: Roof 09 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
01h - Attached - Down Rainwater pipes
Location: Roof 10 01a - Attached - Covering Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B B B
£0 £0 £0
8 15 6
0 0 0
0 0 0 0 0 0
0 0 0
2017 2024 2015
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
B
£0
6
0
0 0
0
2015
Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
B B B
£0 £0 £0
6 8 6
0 0 0
0 0 0 0 0 0
0 0 0
2015 2017 2015
Mineral felt with stone chippings. Timber. Mineral felt.
02a - Flat - Covering 02b - Flat - Decking
B B
£0 £0
6 8
0 0
0 0 0 0
0 0
2015 2017
Mineral felt with stone chippings. Timber.
02c - Flat - Flashing
B
£0
6
0
0 0
0
2015
Mineral felt.
B B B
£0 £0 £0
6 8 6
0 0 0
0 0 0 0 0 0
0 0 0
2015 2017 2015
Mineral felt with stone chippings. Timber. Mineral felt.
01h - Attached - Down Rainwater pipes
Location: Roof 11 02a - Flat - Covering 02b - Flat - Decking 02c - Flat - Flashing
Location: Roof 12
Location: Roof 13 02a - Flat - Covering 02b - Flat - Decking 02c - Flat - Flashing
Location: Roof 14 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02a - Flat - Covering
B(C)
02b - Flat - Decking
Cost to B Rem Life Priority C L
R
Year
£500
1
2
0 0
0
2010
B
£0
6
0
0 0
0
2015
02d - Flat - Parapets
B
£0
6
0
0 0
0
2015
02i - Flat - Skylights
B
£0
6
0
0 0
0
2015
£500
3
2
0 0
0
2012
Notes
Remedial Action
Mineral felt: Requires replacing due to age and condition. Timber.
Brickwork with metal sheet coping. Polycarbonate domed skylights.
Location: Roof 15 02a - Flat - Covering
B(C)
Mineral felt: Requires replacing due to age and condition. Timber.
02b - Flat - Decking
B
£0
6
0
0 0
0
2015
02d - Flat - Parapets
B
£0
6
0
0 0
0
2015
02i - Flat - Skylights
B
£0
6
0
0 0
0
2015
Brickwork with metal sheet coping. Polycarbonate domed skylights.
B B
£0 £0
10 20
0 0
0 0 0 0
0 0
2019 2029
Mineral felt. Timber.
Location: Roof 16 02a - Flat - Covering 02b - Flat - Decking
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
02c - Flat - Flashing
C
£2,500
0
1
0 0
0
2009
Temporary tape: Requires replacement with a lead alternative product. Brickwork with metal sheet coping and metal tubular rails.
02d - Flat - Parapets
B
£0
10
0
0 0
0
2019
02h - Flat - Down Rainwater pipes
B
£0
10
0
0 0
0
2019
PVCU - Internal.
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
£0
10
0
0 0
0
2019
Natural convector in good order.
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
Facet: 2 - Engineering I - Engineering - Heating Systems
Location: 001-06-0-001 01 - Heat Emitters
Location: 001-06-0-003 01 - Heat Emitters
Location: 001-06-0-004 01 - Heat Emitters
B
Location: 001-06-0-005 01 - Heat Emitters
Sample College Physical Condition Survey
B(C)
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-06-0-007 01 - Heat Emitters
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
£0
10
0
0 0
0
2019
Skirting heating in good order.
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
Location: 001-06-0-008 01 - Heat Emitters
Location: 001-06-0-009 01 - Heat Emitters
Location: 001-06-0-010 01 - Heat Emitters
Location: 001-06-0-011 01 - Heat Emitters
B
Location: 001-06-0-015 01 - Heat Emitters
Location: 001-06-0-016 01 - Heat Emitters
Location: 001-06-0-017 01 - Heat Emitters
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-06-0-018 01 - Heat Emitters
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
B
£0
10
0
0 0
0
2019
Natural convector in good order.
B
£0
10
0
0 0
0
2019
Steel panel radiator in good order.
B
£0
10
0
0 0
0
2019
Skirting heating in good order.
B
£0
10
0
0 0
0
2019
Skirting heating in good order.
B
£0
10
0
0 0
0
2019
Skirting heating in good order.
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
B
£0
10
0
0 0
0
2019
Skirting heating in good order.
B
£0
10
0
0 0
0
2019
Skirting heating in good order.
B
£0
10
0
0 0
0
2019
Skirting heating in good order.
Location: 001-06-0-019 01 - Heat Emitters
Location: 001-06-0-020 01 - Heat Emitters
Location: 001-06-0-021 01 - Heat Emitters
Location: 001-06-0-022 01 - Heat Emitters
Location: 001-06-0-023 01 - Heat Emitters
Location: 001-06-0-037 01 - Heat Emitters
B(C)
Location: 001-06-0-038 01 - Heat Emitters
Location: 001-06-0-039 01 - Heat Emitters
Location: 001-06-0-040 01 - Heat Emitters
Location: 001-06-0-042 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
£0
10
0
0 0
0
2019
Skirting heating in good order.
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
Location: 001-06-0-044 01 - Heat Emitters
Location: 001-06-0-045 01 - Heat Emitters
Location: 001-06-0-047 01 - Heat Emitters
Location: 001-06-0-048 01 - Heat Emitters
B
Location: 001-06-0-051 01 - Heat Emitters
Location: 001-06-0-052 01 - Heat Emitters
Location: 001-06-0-053 01 - Heat Emitters
Location: 001-06-0-054 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
B(C)
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
£0
10
0
0 0
0
2019
2No. steel panel radiators in good order.
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
£0
12
0
0 0
0
2021
Natural convector in good order.
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
B(C)
£1,000
2
3
0 0
0
2011
2No. natural convectors require upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
Location: 001-06-0-055 01 - Heat Emitters
B
Location: 001-06-0-056 01 - Heat Emitters
Location: 001-06-0-058 01 - Heat Emitters
Location: 001-06-0-059 01 - Heat Emitters
B
Location: 001-06-0-060 01 - Heat Emitters
Location: 001-06-0-064 01 - Heat Emitters
Location: 001-06-0-066 01 - Heat Emitters
Location: 001-06-0-068 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
10
0
0 0
0
2019
Heat emitter with low surface temperature cover in good order.
B
£0
10
0
0 0
0
2019
Skirting heating in good order.
B(C)
£1,000
2
3
0 0
0
2011
2No. natural convectors require upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
B B
£0 £0
10 10
0 0
0 0 0 0
0 0
2019 2019
Skirting heating in good order. Fan convector in good order.
B
£0
10
0
0 0
0
2019
Skirting heating in good order.
C
£500
0
2
0 0
0
2009
Steel panel radiator with no low surface temperature cover requires replacement
B
£0
10
0
0 0
0
2019
Skirting heating in good order.
£500
2
3
0 0
0
2011
Natural convector requires upgrading within the maintenance schedule.
Location: 001-06-0-070 01 - Heat Emitters
Location: 001-06-0-073 01 - Heat Emitters
Location: 001-06-0-075 01 - Heat Emitters
Location: 001-06-0-076 01 - Heat Emitters 01 - Heat Emitters
Location: 001-06-0-077 01 - Heat Emitters
Location: 001-06-0-080 01 - Heat Emitters
Location: 001-06-0-083 01 - Heat Emitters
Location: 001-06-0-086 01 - Heat Emitters
B(C)
Location: 001-06-0-088 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B B
£0 £0
10 10
0 0
0 0 0 0
0 0
2019 2019
Fan convector in good order. Skirting heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
Location: 001-06-0-101 01 - Heat Emitters
Location: 001-06-0-103 01 - Heat Emitters
Location: 001-06-0-105 01 - Heat Emitters
Location: 001-06-0-107 01 - Heat Emitters
Location: 001-06-0-109 01 - Heat Emitters
Location: 001-06-0-111 01 - Heat Emitters
Location: 001-06-0-112 01 - Heat Emitters
Location: 001-06-0-115 01 - Heat Emitters
Location: 001-06-0-117
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
10
0
0 0
0
2019
Heat emitter with low surface temperature cover in good order.
B
£0
10
0
0 0
0
2019
Skirting heating in good order.
B
£0
10
0
0 0
0
2019
Skirting heating in good order.
01 - Heat Emitters
B
£0
10
0
0 0
0
2019
01 - Heat Emitters
B
£0
15
0
0 0
0
2024
Skirting heating in the Care Staff Rest Room in good order. Heat emitters with low surface temperature covers in good order.
Location: 001-06-0-120 01 - Heat Emitters
Location: 001-06-0-122 01 - Heat Emitters
Location: 001-06-0-123 01 - Heat Emitters
Location: 001-06-0-124 01 - Heat Emitters
Location: 001-06-1-001 01 - Heat Emitters
Location: 001-06-1-002 01 - Heat Emitters
Location: 001-06-1-003 01 - Heat Emitters
Location: Lower Ground
K - Engineering - Vent & Air Con Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: Lower Ground 01 - Ductwork
B
£0
12
0
0 0
0
2021
Ductwork in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
C
£200
0
2
0 0
0
2009
Door closer clashes with the pipes and requires attention.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
M - Engineering - Hot/Cold Water
Location: 001-06-0-002 03 - Blending Valves
Location: 001-06-0-006 03 - Blending Valves
Location: 001-06-0-022 03 - Blending Valves
Location: 001-06-0-023 03 - Blending Valves
Location: 001-06-0-024 03 - Blending Valves
Location: 001-06-0-026 02 - Pipework
Location: 001-06-0-037 03 - Blending Valves
Location: 001-06-0-043 03 - Blending Valves
Location: 001-06-0-057 03 - Blending Valves
Location: 001-06-0-077 03 - Blending Valves
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-06-0-102 03 - Blending Valves
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
Location: 001-06-0-104 03 - Blending Valves
Location: 001-06-0-106 03 - Blending Valves
Location: 001-06-0-108 03 - Blending Valves
Location: 001-06-0-110 03 - Blending Valves
Location: 001-06-0-111 03 - Blending Valves
Location: 001-06-0-113 03 - Blending Valves
Location: 001-06-0-116 03 - Blending Valves
Location: 001-06-0-118 03 - Blending Valves
Location: 001-06-0-121 03 - Blending Valves
Location: 001-06-0-122 03 - Blending Valves P - Engineering - Main Plant
Location: 001-06-0-002 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Extract Fans
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Silavent extract fan in good order.
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Extract fan in good order.
Location: 001-06-0-006 04 - Extract Fans
Location: 001-06-0-019 04 - Extract Fans
Location: 001-06-0-024 04 - Extract Fans
Location: 001-06-0-025 04 - Extract Fans
Location: 001-06-0-035 04 - Extract Fans
Location: 001-06-0-037 04 - Extract Fans
Location: 001-06-0-043 04 - Extract Fans
Location: 001-06-0-057 04 - Extract Fans
Location: 001-06-0-068 04 - Extract Fans
Location: 001-06-0-071 04 - Extract Fans
Location: 001-06-0-079 04 - Extract Fans
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-06-0-102 04 - Extract Fans
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Extract fan in good order.
B
£0
12
0
0 0
0
2021
Xpelair extract fan in good order.
Location: 001-06-0-104 04 - Extract Fans
Location: 001-06-0-106 04 - Extract Fans
Location: 001-06-0-108 04 - Extract Fans
Location: 001-06-0-110 04 - Extract Fans
Location: 001-06-0-111 04 - Extract Fans
Location: 001-06-0-113 04 - Extract Fans
Location: 001-06-0-114 04 - Extract Fans
Location: 001-06-0-116 04 - Extract Fans
Location: 001-06-0-118 04 - Extract Fans
Location: 001-06-0-121 04 - Extract Fans
Location: Lower Ground 04 - Extract Fans Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
R - Engineering - Electrical
Location: 001-06-0-001 04 - Lighting Installation
B(C)
£200
3
3
0 0
0
2012
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
£200
3
3
0 0
0
2012
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-06-0-002 Surface fluorescent light in good order. Emergency light in good order.
Location: 001-06-0-003 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
C
£200
0
2
0 0
0
2009
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
B
£0
12
0
0 0
0
2021
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-06-0-004 Fluorescent light over visual display equipment is not suitable and requires upgrading. Sockets and switches in good order.
Location: 001-06-0-005 04 - Lighting Installation
Surface fluorescent light in good order.
Location: 001-06-0-006 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
2No. surface fluorescent lights in good order. Emergency light in good order.
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
Lighting track in good order. Surface fluorescent light in good order.
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
Lighting track in good order. Surface fluorescent light in good order.
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
Lighting track in good order. Surface fluorescent light in good order.
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light requires upgrading within the maintenance schedule. Sockets and switches in good order.
Location: 001-06-0-007 Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-06-0-008 04 - Lighting Installation 04 - Lighting Installation
Location: 001-06-0-009 04 - Lighting Installation 04 - Lighting Installation
Location: 001-06-0-010 04 - Lighting Installation 04 - Lighting Installation
Location: 001-06-0-011 04 - Lighting Installation
B(C)
£200
3
3
0 0
0
2012
04 - Lighting Installation
B(C)
£200
3
3
0 0
0
2012
B
£0
12
0
0 0
0
2021
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
Location: 001-06-0-015 04 - Lighting Installation Sample College Physical Condition Survey
Lighting track in good order. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
Lighting track in good order. Surface fluorescent light in good order.
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
Lighting track in good order. Surface fluorescent light in good order.
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
Lighting track in good order. Surface fluorescent light in good order.
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B(C)
£400
3
3
0 0
0
2012
MEM distribution board in good order. 2No. surface fluorescent lights require upgrading within the maintenance schedule.
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
2No. CAT II lights in good order. Sockets and switches in good order.
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-06-0-016 04 - Lighting Installation 04 - Lighting Installation
Location: 001-06-0-017 04 - Lighting Installation 04 - Lighting Installation
Location: 001-06-0-018 04 - Lighting Installation 04 - Lighting Installation
Location: 001-06-0-019
Location: 001-06-0-020 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-06-0-021
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-06-0-022 04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
Lighting track in good order. Surface fluorescent light in good order.
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
Lighting track in good order. Surface fluorescent light in good order.
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order. Emergency light in good order.
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
MEM distribution board in good order. Surface fluorescent light in good order.
B
£0
12
0
0 0
0
2021
Location: 001-06-0-023 04 - Lighting Installation 04 - Lighting Installation
Location: 001-06-0-024
Location: 001-06-0-025 2No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-06-0-026 04 - Lighting Installation
Location: 001-06-0-027
Location: 001-06-0-035 04 - Lighting Installation
Surface fluorescent light in good order.
Location: 001-06-0-036
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation
B(C)
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£200
3
3
0 0
0
2012
Surface fluorescent light requires upgrading within the maintenance schedule.
Surface fluorescent light in good order. Emergency light in good order.
Location: 001-06-0-037 04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
Lighting track in good order. Sockets and switches in good order.
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
Lighting track in good order. Surface fluorescent light in good order.
Location: 001-06-0-038 Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-06-0-039 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-06-0-040
Location: 001-06-0-041 04 - Lighting Installation
Location: 001-06-0-042 04 - Lighting Installation 04 - Lighting Installation
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 06 - Sockets/Switches
B
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£0
12
0
0 0
0
2021
Sockets and switches in good order.
£200
5
3
0 0
0
2014
CAT II light requires upgrading within the maintenance schedule. Surface fluorescent light in good order.
Location: 001-06-0-043 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
Location: 001-06-0-044 Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-06-0-045 Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-06-0-047 Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-06-0-048
Sample College Physical Condition Survey
Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-06-0-051 04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
Lighting track in good order. Sockets and switches in good order.
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
Lighting track in good order. Sockets and switches in good order.
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
£600
5
3
0 0
0
2014
Location: 001-06-0-052
Location: 001-06-0-053 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-06-0-054
Location: 001-06-0-055 04 - Lighting Installation
B(C)
05 - Emergency Lighting 06 - Sockets/Switches
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
3No. CAT II light requires upgrading within the maintenance schedule. Emergency light in good order. Sockets and switches in good order.
Location: 001-06-0-056 04 - Lighting Installation 04 - Lighting Installation
Sample College Physical Condition Survey
Lighting track in good order. Surface fluorescent light in good order. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 06 - Sockets/Switches
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
12
0
0 0
0
2021
Sockets and switches in good order.
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order. Emergency light in good order.
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
B
£0
12
0
0 0
0
2021
2No. surface fluorescent lights in good order.
04 - Lighting Installation
C
£200
0
2
0 0
0
2009
04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
Fluorescent light over visual display equipment is not suitable and requires upgrading. Lighting track in good order. Sockets and switches in good order.
£0 £0 £200
30 30 5
0 0 3
0 0 0 0 0 0
0 0 0
2039 2039 2014
Incoming cable in good order. MEM switchgear in good order. Surface fluorescent light requires upgrading within the maintenance schedule.
£0
12
0
0 0
0
2021
3No. surface fluorescent lights in good order.
Location: 001-06-0-057
Location: 001-06-0-058 Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-06-0-059 04 - Lighting Installation
Location: 001-06-0-060
Location: 001-06-0-061 01 - Incoming Cable 02 - Main Switchgear 04 - Lighting Installation
B B B(C)
Location: 001-06-0-062 04 - Lighting Installation
Sample College Physical Condition Survey
B
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 05 - Emergency Lighting
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
12
0
0 0
0
2021
Emergency light in good order.
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
3No. surface fluorescent lights in good order. Emergency light in good order.
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B(C)
£200
3
3
0 0
0
2012
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
Location: 001-06-0-063
Location: 001-06-0-064 3No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-06-0-065 3No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-06-0-066 MEM distribution board in good order. 2No. surface fluorescent lights in good order.
Location: 001-06-0-067 MEM distribution board in good order. Tungsten light requires upgrading within the maintenance schedule. Emergency light in good order.
Location: 001-06-0-068 Surface fluorescent light in good order. Emergency light in good order.
Location: 001-06-0-070 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation
06 - Sockets/Switches
B(C)
B
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£400
5
3
0 0
0
2014
2No. tungsten lights require upgrading within the maintenance schedule. Sockets and switches in good order.
£0
12
0
0 0
0
2021
£200
3
3
0 0
0
2012
Surface fluorescent light requires upgrading within the maintenance schedule.
3No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-06-0-071 04 - Lighting Installation
B(C)
Location: 001-06-0-072 04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
Location: 001-06-0-073 3No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-06-0-074 3No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-06-0-075 MEM distribution board in good order. 3No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-06-0-076
Sample College Physical Condition Survey
Surface fluorescent light in good order. Emergency light in good order. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-06-0-077 04 - Lighting Installation
B
£0
12
0
0 0
0
2021
2No. surface fluorescent lights in good order.
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
£400
5
3
0 0
0
2014
B
£0
12
0
0 0
0
2021
2No. tungsten lights require upgrading within the maintenance schedule. Sockets and switches in good order.
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
£400
5
3
0 0
0
2014
Location: 001-06-0-078 04 - Lighting Installation
Location: 001-06-0-079 04 - Lighting Installation
Location: 001-06-0-080 04 - Lighting Installation
06 - Sockets/Switches
B(C)
Location: 001-06-0-082 3No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-06-0-083 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
2No. tungsten lights require upgrading within the maintenance schedule. 2No. surface fluorescent lights in good order.
Location: 001-06-0-084 3No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-06-0-085 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
3No. surface fluorescent lights in good order. Emergency light in good order.
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
B
£0
12
0
0 0
0
2021
8No. surface fluorescent lights in good order.
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
3No. surface fluorescent lights in good order. Emergency light in good order.
B B B
£0 £0 £0
10 10 12
0 0 0
0 0 0 0 0 0
0 0 0
2019 2019 2021
Lighting track in good order. CAT II light in good order. Sockets and switches in good order.
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
B B B
£0 £0 £0
10 10 12
0 0 0
0 0 0 0 0 0
0 0 0
2019 2019 2021
CAT II light in good order. Lighting track in good order. Sockets and switches in good order.
Location: 001-06-0-086 MEM distribution board in good order. 2No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-06-0-088 04 - Lighting Installation
Location: 001-06-0-089
Location: 001-06-0-101 04 - Lighting Installation 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-06-0-102 04 - Lighting Installation
Location: 001-06-0-103 04 - Lighting Installation 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-06-0-104 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
B B B
£0 £0 £0
10 10 12
0 0 0
0 0 0 0 0 0
0 0 0
2019 2019 2021
CAT II light in good order. Lighting track in good order. Sockets and switches in good order.
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
B B B
£0 £0 £0
10 10 12
0 0 0
0 0 0 0 0 0
0 0 0
2019 2019 2021
CAT II light in good order. Lighting track in good order. Sockets and switches in good order.
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
B B B
£0 £0 £0
10 10 12
0 0 0
0 0 0 0 0 0
0 0 0
2019 2019 2021
Lighting track in good order. CAT II light in good order. Sockets and switches in good order.
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
B
£0
12
0
0 0
0
2021
2No. surface fluorescent lights in good order.
Location: 001-06-0-105 04 - Lighting Installation 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-06-0-106 04 - Lighting Installation
Location: 001-06-0-107 04 - Lighting Installation 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-06-0-108 04 - Lighting Installation
Location: 001-06-0-109 04 - Lighting Installation 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-06-0-110 04 - Lighting Installation
Location: 001-06-0-111 04 - Lighting Installation
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-06-0-112 04 - Lighting Installation 04 - Lighting Installation 06 - Sockets/Switches
B B B
£0 £0 £0
10 10 12
0 0 0
0 0 0 0 0 0
0 0 0
2019 2019 2021
Lighting track in good order. CAT II light in good order. Sockets and switches in good order.
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
B B B
£0 £0 £0
10 10 12
0 0 0
0 0 0 0 0 0
0 0 0
2019 2019 2021
CAT II light in good order. Lighting track in good order. Sockets and switches in good order.
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
B B B
£0 £0 £0
10 10 12
0 0 0
0 0 0 0 0 0
0 0 0
2019 2019 2021
Lighting track in good order. CAT II light in good order. Sockets and switches in good order.
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
Location: 001-06-0-113 04 - Lighting Installation
Location: 001-06-0-114 04 - Lighting Installation
Location: 001-06-0-115 04 - Lighting Installation 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-06-0-116 04 - Lighting Installation
Location: 001-06-0-117 04 - Lighting Installation 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-06-0-118 04 - Lighting Installation
Location: 001-06-0-119
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
MEM distribution board in good order. Surface fluorescent light in good order.
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
B B B
£0 £0 £0
10 10 12
0 0 0
0 0 0 0 0 0
0 0 0
2019 2019 2021
Lighting track in good order. CAT II light in good order. Sockets and switches in good order.
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
B
£0
12
0
0 0
0
2021
Sockets and switches in good order.
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
22No. surface fluorescent lights in good order. 4No. emergency lights in good order.
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
£200
3
3
0 0
0
2012
Tungsten light requires upgrading within the maintenance schedule.
Location: 001-06-0-120 04 - Lighting Installation 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-06-0-121 04 - Lighting Installation
Location: 001-06-0-122 04 - Lighting Installation
Location: 001-06-0-123 06 - Sockets/Switches
Location: 001-06-0-124
Location: 001-06-1-001 04 - Lighting Installation
Location: 001-06-1-002 04 - Lighting Installation
Sample College Physical Condition Survey
B(C)
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 06 - Sockets/Switches
B
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£0
12
0
0 0
0
2021
Sockets and switches in good order.
£200
3
3
0 0
0
2012
£0
12
0
0 0
0
2021
Tungsten light requires upgrading within the maintenance schedule. Sockets and switches in good order.
£200
3
3
0 0
0
2012
Location: 001-06-1-003 04 - Lighting Installation
06 - Sockets/Switches
B(C)
B
Location: 001-06-1-004 04 - Lighting Installation
B(C)
Tungsten light requires upgrading within the maintenance schedule. Emergency light in good order.
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B(C)
£200
3
3
0 0
0
2012
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting 06 - Sockets/Switches
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
Location: Lower Ground Square D distribution board in good order. MEM distribution board in good order. Surface fluorescent light in the Care Staff Rest Room requires upgrading within the maintenance schedule. Surface fluorescent lights in good order. Emergency lights in good order. Sockets and switches in good order.
V - Engineering - Fire Alarms
Location: 001-06-0-001 03 - Smoke Detectors
Location: 001-06-0-002 03 - Smoke Detectors Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-06-0-003 03 - Smoke Detectors
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
Location: 001-06-0-004 03 - Smoke Detectors
Location: 001-06-0-005 03 - Smoke Detectors
Location: 001-06-0-007 03 - Smoke Detectors
Location: 001-06-0-008 03 - Smoke Detectors
Location: 001-06-0-009 03 - Smoke Detectors
Location: 001-06-0-010 03 - Smoke Detectors
Location: 001-06-0-011 03 - Smoke Detectors
Location: 001-06-0-015 03 - Smoke Detectors
Location: 001-06-0-016 03 - Smoke Detectors
Location: 001-06-0-017 03 - Smoke Detectors
Location: 001-06-0-018 03 - Smoke Detectors Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-06-0-020 03 - Smoke Detectors
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
Location: 001-06-0-021 03 - Smoke Detectors
Location: 001-06-0-022 03 - Smoke Detectors
Location: 001-06-0-023 03 - Smoke Detectors
Location: 001-06-0-025 03 - Smoke Detectors
Location: 001-06-0-026 03 - Smoke Detectors
Location: 001-06-0-027 03 - Smoke Detectors
Location: 001-06-0-035 03 - Smoke Detectors
Location: 001-06-0-036 03 - Smoke Detectors
Location: 001-06-0-038 03 - Smoke Detectors
Location: 001-06-0-039 03 - Smoke Detectors
Location: 001-06-0-040 03 - Smoke Detectors Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-06-0-041 03 - Smoke Detectors
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
Location: 001-06-0-042 03 - Smoke Detectors
Location: 001-06-0-043 03 - Smoke Detectors
Location: 001-06-0-044 03 - Smoke Detectors
Location: 001-06-0-045 03 - Smoke Detectors
Location: 001-06-0-047 03 - Smoke Detectors
Location: 001-06-0-048 03 - Smoke Detectors
Location: 001-06-0-051 03 - Smoke Detectors
Location: 001-06-0-052 03 - Smoke Detectors
Location: 001-06-0-053 03 - Smoke Detectors
Location: 001-06-0-054 03 - Smoke Detectors
Location: 001-06-0-055 03 - Smoke Detectors Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-06-0-056 03 - Smoke Detectors
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
Smoke detector in good order. Fixfire main panel in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
Location: 001-06-0-057 03 - Smoke Detectors
Location: 001-06-0-058 03 - Smoke Detectors
Location: 001-06-0-059 03 - Smoke Detectors
Location: 001-06-0-060 03 - Smoke Detectors
Location: 001-06-0-061 03 - Smoke Detectors
Location: 001-06-0-062 03 - Smoke Detectors 05 - Fire Main/Zone Panel
Location: 001-06-0-063 03 - Smoke Detectors
Location: 001-06-0-064 03 - Smoke Detectors
Location: 001-06-0-065 03 - Smoke Detectors
Location: 001-06-0-066 03 - Smoke Detectors
Location: 001-06-0-067 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Smoke Detectors
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
Location: 001-06-0-070 03 - Smoke Detectors
Location: 001-06-0-071 03 - Smoke Detectors
Location: 001-06-0-072 03 - Smoke Detectors
Location: 001-06-0-074 03 - Smoke Detectors
Location: 001-06-0-075 03 - Smoke Detectors
Location: 001-06-0-076 03 - Smoke Detectors
Location: 001-06-0-079 03 - Smoke Detectors
Location: 001-06-0-080 03 - Smoke Detectors
Location: 001-06-0-082 03 - Smoke Detectors
Location: 001-06-0-083 03 - Smoke Detectors
Location: 001-06-0-084 03 - Smoke Detectors
Location: 001-06-0-085 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Smoke Detectors
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
Location: 001-06-0-088 03 - Smoke Detectors
Location: 001-06-0-089 03 - Smoke Detectors
Location: 001-06-0-101 03 - Smoke Detectors
Location: 001-06-0-103 03 - Smoke Detectors
Location: 001-06-0-105 03 - Smoke Detectors
Location: 001-06-0-107 03 - Smoke Detectors
Location: 001-06-0-109 03 - Smoke Detectors
Location: 001-06-0-111 03 - Smoke Detectors
Location: 001-06-0-112 03 - Smoke Detectors
Location: 001-06-0-115 03 - Smoke Detectors
Location: 001-06-0-117 03 - Smoke Detectors
Location: 001-06-0-119 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Smoke Detectors
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
3No. smoke detectors in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
03 - Smoke Detectors
B
£0
10
0
0 0
0
2019
03 - Smoke Detectors
B
£0
12
0
0 0
0
2021
Smoke detectors in the Care Staff Rest Room in good order. Smoke detectors in good order.
01 - Sounders
B
£0
12
0
0 0
0
2021
02 - Call Points
B
£0
12
0
0 0
0
2021
Location: 001-06-0-120 03 - Smoke Detectors
Location: 001-06-0-123 03 - Smoke Detectors
Location: 001-06-0-124 03 - Smoke Detectors
Location: 001-06-1-002 03 - Smoke Detectors
Location: 001-06-1-003 03 - Smoke Detectors
Location: 001-06-1-004 03 - Smoke Detectors
Location: Lower Ground Floor
Location: Whole Block
Block Total
Sample College Physical Condition Survey
Fire alarm sounders in good order. Fire alarm call points in good order.
£182,331.00
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Site : Sample College - 001 Block : C Hostel - 07 Facet: 1 - Building A - Building - Physical Structure
Location: Whole Block 01 - General Structure 02 - Foundations 03 - Ground Stability
B B B
£0 £0 £0
40 60 60
0 0 0
0 0 0 0 0 0
0 0 0
2049 2069 2069
Brickwork: Generally sound. Generally sound. Generally sound.
04 - Windows
C
£1,800
0
1
0 0
0
2009
04 - Windows
B(C)
£1,150
1
2
0 0
0
2010
06 - Doors
B(C)
£200
3
3
0 0
0
2012
Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 1 - 4No. Softwood timber - Single: Replace with new located to elevation 1 - 1No. Softwood timber: Redecorate and make good located to elevation 1 - 1No. single.
B - Building - External Fabric
Location: Elevation 01
Location: Elevation 02 02a - Cladding - Attachment
B
£0
8
0
0 0
0
2017
02b - Cladding - Cracking
B
£0
8
0
0 0
0
2017
02c - Cladding - Joints
B
£0
8
0
0 0
0
2017
Sample College Physical Condition Survey
Plastic profiled sheet cladding: Located to elevation 2 (two storey section). Plastic profiled sheet cladding: Located to elevation 2 (two storey section). Plastic profiled sheet cladding: Located to elevation 2 (two storey section).
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
02d - Cladding - Finish
B
£0
8
0
0 0
0
2017
Plastic profiled sheet cladding: Located to elevation 2 (two storey section). Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 2 - 12No. Steel: Need to replace located to elevation 2 - 1No. single.
04 - Windows
C
£5,400
0
1
0 0
0
2009
06 - Doors
C
£1,250
0
1
0 0
0
2009
04 - Windows
C
£4,500
0
1
0 0
0
2009
04 - Windows
B(C)
£2,300
1
2
0 0
0
2010
06 - Doors
B(C)
£800
3
3
0 0
0
2012
C
£2,700
0
1
0 0
0
2009
Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 4 - 6No.
04 - Windows
C
£5,400
0
1
0 0
0
2009
04 - Windows
B(C)
£1,150
1
2
0 0
0
2010
06 - Doors
B(C)
£600
3
3
0 0
0
2012
Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 5 - 12No. Softwood timber - Single: Replace with new located to elevation 5 - 1No. Softwood timber: Redecorate and make good located to elevation 5 - 3No. single.
Location: Elevation 03 Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 3 - 10No. Softwood timber - Single: Replace with new located to elevation 3 - 2No. Softwood timber: Redecorate and make good located to elevation 3 - 4No. single.
Location: Elevation 04 04 - Windows
Location: Elevation 05
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: Whole Block 01a - Masonry - Cracking 01b - Masonry - Spalling 01c - Masonry - Pointing 01d - Masonry - Finish 02a - Cladding - Attachment 02a - Cladding - Attachment 02b - Cladding - Cracking 02c - Cladding - Joints 02d - Cladding - Finish 04 - Windows 06 - Doors
B B B B B B B B B B B
£0 £0 £0 £0 £0 £0 £0 £0 £0 £0 £0
20 20 20 20 6 6 6 6 6 6 6
0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0
2029 2029 2029 2029 2015 2015 2015 2015 2015 2015 2015
Brickwork. Brickwork. Brickwork. Brickwork. Zinc sheet. Zinc sheet. Zinc sheet. Zinc sheet. Zinc sheet. PVCU - Double. Aluminium.
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
C - Building - Internal Fabric
Location: 001-07-0-001 01 - Decorations
02 - Ceiling
B(C)
B
03 - Floor
B(C)
£350
4
3
0 0
0
2013
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
Location: 001-07-0-002 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
£350
2
3
0 0
0
2011
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
6
0
0 0
0
2015
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
Notes
Remedial Action
Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-07-0-003 01 - Decorations
02 - Ceiling
B(C)
B
03 - Floor
B(C)
£350
4
3
0 0
0
2013
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
£350
4
3
0 0
0
2013
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-07-0-004 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-07-0-004a Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
R
Year
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
£350
4
3
0 0
0
2013
£0
6
0
0 0
0
2015
£650
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
£875
4
3
0 0
0
2013
£0
6
0
0 0
0
2015
B(C)
£260
3
4
0 0
0
2012
02 - Ceiling
C
£100
0
3
0 0
0
2009
03 - Floor
B
£0
6
0
0 0
0
2015
£260
3
4
0 0
0
2012
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
Cost to B Rem Life Priority C L
B B(C)
B
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-07-0-004b 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-07-0-005 01 - Decorations
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Anti-slip vinyl sheet flooring: In good condition.
Location: 001-07-0-006 01 - Decorations
Sample College Physical Condition Survey
B(C)
Redecoration required as part of a regular maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
£350
4
3
0 0
0
2013
£0
8
0
0 0
0
2017
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
£350
4
3
0 0
0
2013
£0
8
0
0 0
0
2017
Notes
Remedial Action
Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-07-0-007 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-07-0-008 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-07-0-009
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling
B(C)
B
Cost to B Rem Life Priority C L
R
Year
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
03 - Floor
B(C)
£350
4
3
0 0
0
2013
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-07-0-010 01 - Decorations
02 - Ceiling
B
03 - Floor
B(C)
£350
4
3
0 0
0
2013
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£390
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
£525
4
3
0 0
0
2013
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-07-0-011 01 - Decorations
02 - Ceiling 03 - Floor
Sample College Physical Condition Survey
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-0-011a 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B B(C)
£130
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£175
2
3
0 0
0
2011
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-07-0-015 01 - Decorations
02 - Ceiling
B(C)
B
03 - Floor
B(C)
£350
4
3
0 0
0
2013
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£520
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-07-0-016 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
08 - Fixed Units
B(C)
B
Cost to B Rem Life Priority C L
R
Year
£700
4
3
0 0
0
2013
£0
8
0
0 0
0
2017
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
Notes
Remedial Action
Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-07-0-017 01 - Decorations
02 - Ceiling
B(C)
B
03 - Floor
B(C)
£350
4
3
0 0
0
2013
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-07-0-018 01 - Decorations
02 - Ceiling
B
03 - Floor
B(C)
£350
4
3
0 0
0
2013
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-07-0-019 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£350
4
3
0 0
0
2013
B(C)
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
£350
4
3
0 0
0
2013
£0
8
0
0 0
0
2017
£520
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
£700
4
3
0 0
0
2013
£0
8
0
0 0
0
2017
B
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition.
Location: 001-07-0-020 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-07-0-021 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-07-0-022
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Cost to B Rem Life Priority C L
R
Year
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
£350
4
3
0 0
0
2013
£0
8
0
0 0
0
2017
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
£350
4
3
0 0
0
2013
£0
8
0
0 0
0
2017
£208
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£280
2
3
0 0
0
2011
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-07-0-023 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-07-0-024 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B B(C)
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-0-025 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B B(C)
£390
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£525
2
3
0 0
0
2011
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£104
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£140
4
3
0 0
0
2013
01 - Decorations
B(C)
£130
4
4
0 0
0
2013
02 - Ceiling 03 - Floor
B B(C)
£0 £175
10 3
0 3
0 0 0 0
0 0
2019 2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-07-0-026 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition.
Location: 001-07-0-027 Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-07-0-035 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
Cost to B Rem Life Priority C L
R
Year
£130
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£175
4
3
0 0
0
2013
£0
6
0
0 0
0
2015
£156
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£210
4
3
0 0
0
2013
B(C)
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£350
2
3
0 0
0
2011
B B(C)
B
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Fixed units: Sink unit in good condition.
Location: 001-07-0-036 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-07-0-037 01 - Decorations
02 - Ceiling 03 - Floor
B B(C)
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-07-0-038 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Cost to B Rem Life Priority C L
R
Year
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
£350
4
3
0 0
0
2013
£0
8
0
0 0
0
2017
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
£350
4
3
0 0
0
2013
£0
8
0
0 0
0
2017
£520
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
£700
4
3
0 0
0
2013
£0
8
0
0 0
0
2017
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-07-0-039 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-07-0-040 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-07-0-041 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
R
Year
£130
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£175
4
3
0 0
0
2013
B(C)
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
£350
4
3
0 0
0
2013
£0
8
0
0 0
0
2017
B(C)
£260
3
4
0 0
0
2012
02 - Ceiling
C
£100
0
3
0 0
0
2009
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
8
0
0 0
0
2017
02 - Ceiling 03 - Floor
B(C)
Cost to B Rem Life Priority C L
B
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-07-0-042 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-07-0-043 01 - Decorations
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-07-0-044
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling
B(C)
B
Cost to B Rem Life Priority C L
R
Year
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
03 - Floor
B(C)
£350
4
3
0 0
0
2013
08 - Fixed Units
B(C)
£1,250
2
2
0 0
0
2011
B(C)
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
£350
4
3
0 0
0
2013
£0
8
0
0 0
0
2017
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
£350
4
3
0 0
0
2013
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-07-0-045 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-07-0-047 01 - Decorations
02 - Ceiling 03 - Floor
Sample College Physical Condition Survey
B(C)
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 08 - Fixed Units
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£1,250
2
2
0 0
0
2011
Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
B(C)
£130
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
B(C)
£175
2
3
0 0
0
2011
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition.
B(C)
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
Location: 001-07-0-048 01 - Decorations
02 - Ceiling 03 - Floor
B
Location: 001-07-0-051 01 - Decorations
02 - Ceiling
B
03 - Floor
B(C)
£350
4
3
0 0
0
2013
08 - Fixed Units
B(C)
£1,250
2
2
0 0
0
2011
B(C)
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-07-0-052 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
03 - Floor
B(C)
£350
4
3
0 0
0
2013
08 - Fixed Units
B(C)
£1,250
2
2
0 0
0
2011
B(C)
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
Notes
Remedial Action
Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-07-0-053 01 - Decorations
02 - Ceiling
B
03 - Floor
B(C)
£350
4
3
0 0
0
2013
08 - Fixed Units
B(C)
£1,250
2
2
0 0
0
2011
B(C)
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
£350
4
3
0 0
0
2013
£0
8
0
0 0
0
2017
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-07-0-054 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-07-0-055 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Cost to B Rem Life Priority C L
R
Year
£520
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£700
2
3
0 0
0
2011
£0
6
0
0 0
0
2015
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-07-0-056 01 - Decorations
02 - Ceiling
B(C)
B
03 - Floor
B(C)
£350
4
3
0 0
0
2013
08 - Fixed Units
B(C)
£1,250
2
2
0 0
0
2011
B(C)
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£350
2
3
0 0
0
2011
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-07-0-057 01 - Decorations
02 - Ceiling 03 - Floor
05 - Condition of Internal Walls Sample College Physical Condition Survey
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Ceramic wall tiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 08 - Fixed Units
B
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£0
10
0
0 0
0
2019
Sanitary fittings: In good condition.
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-07-0-058 01 - Decorations
02 - Ceiling
B(C)
B
03 - Floor
B(C)
£350
4
3
0 0
0
2013
08 - Fixed Units
B(C)
£1,250
2
2
0 0
0
2011
B(C)
£156
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£210
2
3
0 0
0
2011
£0
6
0
0 0
0
2015
£1,500
4
2
0 0
0
2013
£0
6
0
0 0
0
2015
Location: 001-07-0-059 01 - Decorations
02 - Ceiling 03 - Floor
05 - Condition of Internal Walls
B B(C)
B
08 - Fixed Units
B(C)
08 - Fixed Units
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Ceramic wall tiling: In good condition. Fixed units: Fitted unit requires replacement within the maintenance schedule due to age and level of deterioration. Fixed units: Sluice in good condition.
Location: 001-07-0-060 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling
B(C)
B
Cost to B Rem Life Priority C L
R
Year
£260
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
03 - Floor
B(C)
£350
4
3
0 0
0
2013
08 - Fixed Units
B(C)
£1,250
2
2
0 0
0
2011
01 - Decorations
B(C)
£208
2
4
0 0
0
2011
02 - Ceiling 03 - Floor
B B(C)
£0 £280
6 2
0 3
0 0 0 0
0 0
2015 2011
B(C)
£390
1
4
0 0
0
2010
£0
6
0
0 0
0
2015
B(C)
£525
4
3
0 0
0
2013
B(C)
£312
3
4
0 0
0
2012
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-07-0-061 Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition.
Location: 001-07-0-062 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-07-0-063 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02 - Ceiling 03 - Floor
Cost to B Rem Life Priority C L
R
Year
C
£100
0
3
0 0
0
2009
B(C)
£420
4
3
0 0
0
2013
B(C)
£260
3
4
0 0
0
2012
C
£100
0
3
0 0
0
2009
B(C)
£350
4
3
0 0
0
2013
B(C)
£312
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£420
4
3
0 0
0
2013
B(C)
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£350
4
3
0 0
0
2013
Notes
Remedial Action
Suspended ceiling: Replace water damaged tiles. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-07-0-064 01 - Decorations
02 - Ceiling 03 - Floor
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-07-0-065 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-07-0-066 01 - Decorations
02 - Ceiling 03 - Floor
Sample College Physical Condition Survey
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-0-067 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
£312
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£420
4
3
0 0
0
2013
B(C)
£208
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£280
4
3
0 0
0
2013
B(C)
£390
3
4
0 0
0
2012
C
£100
0
3
0 0
0
2009
B(C)
£525
4
3
0 0
0
2013
B(C)
£260
3
4
0 0
0
2012
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-07-0-068 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-07-0-069 01 - Decorations
02 - Ceiling 03 - Floor
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-07-0-070 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02 - Ceiling 03 - Floor
Cost to B Rem Life Priority C L
R
Year
C
£100
0
3
0 0
0
2009
B(C)
£350
4
3
0 0
0
2013
B(C)
£312
3
4
0 0
0
2012
C
£100
0
3
0 0
0
2009
B(C)
£420
4
3
0 0
0
2013
B(C)
£1,430
3
4
0 0
0
2012
£0
15
0
0 0
0
2024
Notes
Remedial Action
Suspended ceiling: Replace water damaged tiles. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-07-0-071 01 - Decorations
02 - Ceiling 03 - Floor
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-07-0-072 01 - Decorations
02 - Ceiling
B
03 - Floor
B(C)
£1,925
4
3
0 0
0
2013
03 - Floor
B(C)
£1,925
4
3
0 0
0
2013
£0
6
0
0 0
0
2015
£5,000
2
2
0 0
0
2011
05 - Condition of Internal Walls 08 - Fixed Units
Sample College Physical Condition Survey
B B(C)
Redecoration required as part of a regular maintenance schedule. Timber panelling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Ceramic wall tiling: In good condition. Fixed units: Kitchen unit requires replacement within the maintenance schedule due to age and level of deterioration. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-0-073 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
£52
4
4
0 0
0
2013
B
£0
6
0
0 0
0
2015
B(C)
£70
4
3
0 0
0
2013
B
£0
10
0
0 0
0
2019
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Sanitary fittings: In good condition.
Location: 001-07-0-074 01 - Decorations
B(C)
£260
4
4
0 0
0
2013
02 - Ceiling 03 - Floor
B B(C)
£0 £350
10 4
0 3
0 0 0 0
0 0
2019 2013
£0
8
0
0 0
0
2017
08 - Fixed Units
B
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Fixed units: Kitchen units in good condition.
Location: 001-07-0-075 01 - Decorations
B(C)
£520
4
4
0 0
0
2013
02 - Ceiling 03 - Floor
B B(C)
£0 £700
10 3
0 3
0 0 0 0
0 0
2019 2012
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-07-0-076
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
Cost to B Rem Life Priority C L
R
Year
B(C)
£312
3
4
0 0
0
2012
C
£100
0
3
0 0
0
2009
B(C)
£420
4
3
0 0
0
2013
B(C)
£1,170
4
4
0 0
0
2013
£0
15
0
0 0
0
2024
B(C)
£1,575
4
3
0 0
0
2013
B(C)
£520
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£700
4
3
0 0
0
2013
B(C)
£312
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-07-0-077 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Timber panelling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition.
Location: 001-07-0-078 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-07-0-079 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£420
4
3
0 0
0
2013
Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
B(C)
£350
4
3
0 0
0
2013
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£104
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£140
2
3
0 0
0
2011
Location: 001-07-0-080 01 - Decorations
02 - Ceiling 03 - Floor
B
Location: 001-07-0-081 01 - Decorations
02 - Ceiling 03 - Floor
B B(C)
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
B(C)
£52
4
4
0 0
0
2013
B
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-07-0-082 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£70
2
3
0 0
0
2011
Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition.
B(C)
£208
4
4
0 0
0
2013
£0
15
0
0 0
0
2024
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Fixed units: Kitchen unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-07-0-083 01 - Decorations
02 - Ceiling
B
03 - Floor
B(C)
£280
2
3
0 0
0
2011
08 - Fixed Units
B(C)
£2,500
1
2
0 0
0
2010
01 - Decorations
B(C)
£468
4
4
0 0
0
2013
02 - Ceiling 03 - Floor
B B(C)
£0 £630
10 2
0 3
0 0 0 0
0 0
2019 2011
B(C)
£312
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
Location: 001-07-0-084 Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition.
Location: 001-07-0-085 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£420
4
3
0 0
0
2013
Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£312
3
4
0 0
0
2012
C
£100
0
3
0 0
0
2009
B(C)
£420
4
3
0 0
0
2013
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£1,430
4
4
0 0
0
2013
£0
6
0
0 0
0
2015
Location: 001-07-0-086 01 - Decorations
02 - Ceiling 03 - Floor
Location: 001-07-0-087 01 - Decorations
02 - Ceiling
B
03 - Floor
B(C)
£1,925
2
3
0 0
0
2011
03 - Floor
B(C)
£1,925
4
3
0 0
0
2013
£0
8
0
0 0
0
2017
£312
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
08 - Fixed Units
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Fixed units: Kitchen units in good condition.
Location: 001-07-0-088 01 - Decorations
02 - Ceiling Sample College Physical Condition Survey
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£420
4
3
0 0
0
2013
Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£130
4
4
0 0
0
2013
C
£150
0
2
0 0
0
2009
B(C)
£175
4
3
0 0
0
2013
£0
10
0
0 0
0
2019
Redecoration required as part of a regular maintenance schedule. Artex ceiling - evidence of water ingress with making good and redecoration required. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Sanitary fittings: In good condition.
Location: 001-07-1-001 01 - Decorations
02 - Ceiling
03 - Floor
08 - Fixed Units
B
Location: 001-07-1-002 01 - Decorations
B(C)
£260
4
4
0 0
0
2013
02 - Ceiling 03 - Floor
B B(C)
£0 £350
10 4
0 3
0 0 0 0
0 0
2019 2013
01 - Decorations
B(C)
£260
4
4
0 0
0
2013
02 - Ceiling 03 - Floor
B B(C)
£0 £350
10 4
0 3
0 0 0 0
0 0
2019 2013
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-07-1-003
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-1-004 01 - Decorations
B(C)
£208
4
4
0 0
0
2013
02 - Ceiling 03 - Floor
B B(C)
£0 £280
10 4
0 3
0 0 0 0
0 0
2019 2013
B B B(C)
£0 £0 £500
10 20 2
0 0 3
0 0 0 0 0 0
0 0 0
2019 2029 2011
B B(C)
£0 £150
60 4
0 3
0 0 0 0
0 0
2069 2013
B B B
£0 £0 £0
60 8 8
0 0 0
0 0 0 0 0 0
0 0 0
2069 2017 2017
B B B B
£0 £0 £0 £0
6 6 10 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2015 2019 2015
B B B
£0 £0 £0
20 20 6
0 0 0
0 0 0 0 0 0
0 0 0
2029 2029 2015
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
D - Building - Roof
Location: Roof 01 01a - Attached - Covering 01b - Attached - Sarking 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins
01f - Attached - Purlins 01g - Attached - Guttering 01g - Attached - Guttering
Metal sheet. Metal sheet. Painted timber: Require redecoration. Metal. Timber pier: Requires restaining - located to central courtyard. Timber. Box gutters - Metal. PVCU.
Location: Roof 02 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01i - Attached - Skylights
Sample College Physical Condition Survey
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. Aluminium framed glazed skylights.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: Roof 03 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
01h - Attached - Down Rainwater pipes
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
B
£0
6
0
0 0
0
2015
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
B
£0
6
0
0 0
0
2015
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
B B B
£0 £0 £0
6 8 15
0 0 0
0 0 0 0 0 0
0 0 0
2015 2017 2024
Concrete tiles. Mineral felt. Lead.
Location: Roof 04 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
01h - Attached - Down Rainwater pipes
Location: Roof 05 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
01h - Attached - Down Rainwater pipes
Cost to B Rem Life Priority C L
R
Year
B
£0
6
0
0 0
0
2015
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
B
£0
6
0
0 0
0
2015
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
B
£0
6
0
0 0
0
2015
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
B B
£0 £0
20 20
0 0
0 0 0 0
0 0
2029 2029
Notes
Remedial Action
Metal sheet coping to brick parapets. Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
Location: Roof 06 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
01h - Attached - Down Rainwater pipes
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
Location: Roof 07 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins Sample College Physical Condition Survey
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
01g - Attached - Guttering
C
£1,000
0
2
0 0
0
2009
01h - Attached - Down Rainwater pipes
B
£0
6
0
0 0
0
2015
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
B
£0
6
0
0 0
0
2015
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
Notes
Remedial Action
Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
Location: Roof 08 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
01h - Attached - Down Rainwater pipes
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
Location: Roof 09 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
Sample College Physical Condition Survey
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01h - Attached - Down Rainwater pipes
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
6
0
0 0
0
2015
PVCU - Internal.
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
B
£0
6
0
0 0
0
2015
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
B B B
£0 £0 £0
6 8 6
0 0 0
0 0 0 0 0 0
0 0 0
2015 2017 2015
Mineral felt with stone chippings. Timber. Mineral felt.
B B B
£0 £0 £0
6 8 6
0 0 0
0 0 0 0 0 0
0 0 0
2015 2017 2015
Mineral felt with stone chippings. Timber. Mineral felt.
B B B
£0 £0 £0
6 8 6
0 0 0
0 0 0 0 0 0
0 0 0
2015 2017 2015
Mineral felt with stone chippings. Timber. Mineral felt.
Location: Roof 10 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
01h - Attached - Down Rainwater pipes
Location: Roof 11 02a - Flat - Covering 02b - Flat - Decking 02c - Flat - Flashing
Location: Roof 12 02a - Flat - Covering 02b - Flat - Decking 02c - Flat - Flashing
Location: Roof 13 02a - Flat - Covering 02b - Flat - Decking 02c - Flat - Flashing
Location: Roof 14
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02a - Flat - Covering
B(C)
02b - Flat - Decking 02d - Flat - Parapets 02h - Flat - Down Rainwater pipes 02i - Flat - Skylights
Cost to B Rem Life Priority C L
R
Year
£500
3
2
0 0
0
2012
B B
£0 £0
6 6
0 0
0 0 0 0
0 0
2015 2015
B B
£0 £0
6 6
0 0
0 0 0 0
0 0
2015 2015
£500
3
2
0 0
0
2012
Notes
Remedial Action
Mineral felt: Requires replacing due to age and condition. Timber. Brickwork with metal sheet coping. PVCU. Polycarbonate domed skylights.
Location: Roof 15 02a - Flat - Covering
B(C)
Mineral felt: Requires replacing due to age and condition. Timber. Brickwork with metal sheet coping. PVCU. Polycarbonate domed skylights.
02b - Flat - Decking 02d - Flat - Parapets
B B
£0 £0
6 6
0 0
0 0 0 0
0 0
2015 2015
02h - Flat - Down Rainwater pipes 02i - Flat - Skylights
B B
£0 £0
6 6
0 0
0 0 0 0
0 0
2015 2015
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
Facet: 2 - Engineering I - Engineering - Heating Systems
Location: 001-07-0-001 01 - Heat Emitters
Location: 001-07-0-003 01 - Heat Emitters
Location: 001-07-0-004 01 - Heat Emitters
Location: 001-07-0-004a
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
B(C)
£800
3
3
0 0
0
2012
2No. natural convectors require upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
£0
10
0
0 0
0
2019
Heat emitter with low surface temperature cover in good order.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
Location: 001-07-0-004b 01 - Heat Emitters
Location: 001-07-0-005 01 - Heat Emitters
Location: 001-07-0-006 01 - Heat Emitters
B
Location: 001-07-0-007 01 - Heat Emitters
Location: 001-07-0-008 01 - Heat Emitters
Location: 001-07-0-009 01 - Heat Emitters
Location: 001-07-0-010 01 - Heat Emitters
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-0-011 01 - Heat Emitters
B
£0
12
0
0 0
0
2021
Skirting heater in good order.
B
£0
10
0
0 0
0
2019
Heat emitter with low surface temperature cover in good order.
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
£0
12
0
0 0
0
2021
Skirting heater in good order.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
B
£0
12
0
0 0
0
2021
Skirting heater in good order.
B
£0
12
0
0 0
0
2021
Skirting heater in good order.
Location: 001-07-0-011a 01 - Heat Emitters
Location: 001-07-0-015 01 - Heat Emitters
B(C)
Location: 001-07-0-016 01 - Heat Emitters
B
Location: 001-07-0-017 01 - Heat Emitters
Location: 001-07-0-018 01 - Heat Emitters
Location: 001-07-0-020 01 - Heat Emitters
Location: 001-07-0-021 01 - Heat Emitters
Location: 001-07-0-022 01 - Heat Emitters
Location: 001-07-0-023 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
12
0
0 0
0
2021
Skirting heater in good order.
B
£0
10
0
0 0
0
2019
Heat emitter with low surface temperature cover in good order.
B
£0
12
0
0 0
0
2021
Natural convector in good order.
C
£400
0
2
0 0
0
2009
Skirting heater requires replacement.
B
£0
12
0
0 0
0
2021
Natural convector in good order.
B
£0
12
0
0 0
0
2021
Skirting heater in good order.
B
£0
12
0
0 0
0
2021
Skirting heater in good order.
B
£0
12
0
0 0
0
2021
Skirting heater in good order.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
Location: 001-07-0-024 01 - Heat Emitters
Location: 001-07-0-025 01 - Heat Emitters
Location: 001-07-0-036 01 - Heat Emitters
Location: 001-07-0-037 01 - Heat Emitters
Location: 001-07-0-038 01 - Heat Emitters
Location: 001-07-0-039 01 - Heat Emitters
Location: 001-07-0-040 01 - Heat Emitters
Location: 001-07-0-041 01 - Heat Emitters
Location: 001-07-0-042 01 - Heat Emitters
Location: 001-07-0-043 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
B
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£0
10
0
0 0
0
2019
Heat emitter with low surface temperature cover in good order.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
Location: 001-07-0-044 01 - Heat Emitters
Location: 001-07-0-045 01 - Heat Emitters
Location: 001-07-0-047 01 - Heat Emitters
Location: 001-07-0-051 01 - Heat Emitters
Location: 001-07-0-052 01 - Heat Emitters
Location: 001-07-0-053 01 - Heat Emitters
Location: 001-07-0-054 01 - Heat Emitters
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-0-055 01 - Heat Emitters
B
£0
10
0
0 0
0
2019
Steel panel radiator in good order.
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
£0
12
0
0 0
0
2021
Natural convector in good order.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
B(C)
£800
3
3
0 0
0
2012
2No. natural convectors require upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
Location: 001-07-0-056 01 - Heat Emitters
B(C)
Location: 001-07-0-059 01 - Heat Emitters
B
Location: 001-07-0-062 01 - Heat Emitters
Location: 001-07-0-064 01 - Heat Emitters
Location: 001-07-0-066 01 - Heat Emitters
Location: 001-07-0-068 01 - Heat Emitters
Location: 001-07-0-071 01 - Heat Emitters
Location: 001-07-0-072 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
Skirting heater in good order. Fan convector in good order.
C
£250
0
2
0 0
0
2009
High efficiency convector with no low surface temperature cover requires replacement.
B
£0
12
0
0 0
0
2021
Skirting heater in good order.
B(C)
£800
3
3
0 0
0
2012
2No. natural convectors require upgrading within the maintenance schedule.
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
B
£0
10
0
0 0
0
2019
Steel panel radiator in good order.
B
£0
10
0
0 0
0
2019
Heat emitter with low surface temperature cover in good order.
B
£0
10
0
0 0
0
2019
Heat emitter with low surface temperature cover in good order.
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
Fan convector in good order. Perimeter heating in good order.
Location: 001-07-0-075 01 - Heat Emitters
Location: 001-07-0-077 01 - Heat Emitters
Location: 001-07-0-078 01 - Heat Emitters
Location: 001-07-0-080 01 - Heat Emitters
Location: 001-07-0-081 01 - Heat Emitters
Location: 001-07-0-084 01 - Heat Emitters
Location: 001-07-0-085 01 - Heat Emitters
Location: 001-07-0-087 01 - Heat Emitters 01 - Heat Emitters
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-0-089 01 - Heat Emitters
B(C)
£400
3
3
0 0
0
2012
Natural convector requires upgrading within the maintenance schedule.
01 - Heat Emitters
B(C)
£400
5
3
0 0
0
2014
01 - Heat Emitters
B
£0
10
0
0 0
0
2019
Fan convector require upgrading within the maintenance schedule. Electric heater in good order.
B
£0
12
0
0 0
0
2021
Blending valve in good order.
B
£0
12
0
0 0
0
2021
Blending valve in good order.
B
£0
12
0
0 0
0
2021
Blending valve in good order.
B
£0
12
0
0 0
0
2021
Blending valve in good order.
B
£0
12
0
0 0
0
2021
Blending valve in good order.
B
£0
12
0
0 0
0
2021
Blending valve in good order.
C
£200
0
2
0 0
0
2009
Boxing around pipes smashed by door require replacement.
B
£0
12
0
0 0
0
2021
Blending valve in good order.
Location: Lower Ground
M - Engineering - Hot/Cold Water
Location: 001-07-0-001 03 - Blending Valves
Location: 001-07-0-003 03 - Blending Valves
Location: 001-07-0-004b 03 - Blending Valves
Location: 001-07-0-006 03 - Blending Valves
Location: 001-07-0-024 03 - Blending Valves
Location: 001-07-0-025 03 - Blending Valves
Location: 001-07-0-026 02 - Pipework
Location: 001-07-0-037 03 - Blending Valves Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-0-043 03 - Blending Valves
B
£0
12
0
0 0
0
2021
Blending valve in good order.
B
£0
12
0
0 0
0
2021
Blending valve in good order.
B
£0
12
0
0 0
0
2021
Blending valve in good order.
B
£0
12
0
0 0
0
2021
Blending valve in good order.
B
£0
12
0
0 0
0
2021
Blending valve in good order.
B
£0
12
0
0 0
0
2021
Vent Axia extract fan in good order.
B
£0
12
0
0 0
0
2021
Vent Axia extract fan in good order.
B
£0
12
0
0 0
0
2021
Vent Axia extract fan in good order.
B
£0
12
0
0 0
0
2021
Vent Axia extract fan in good order.
B
£0
12
0
0 0
0
2021
Vent Axia extract fan in good order.
Location: 001-07-0-057 03 - Blending Valves
Location: 001-07-0-058 03 - Blending Valves
Location: 001-07-0-060 03 - Blending Valves
Location: 001-07-0-073 03 - Blending Valves P - Engineering - Main Plant
Location: 001-07-0-001 04 - Extract Fans
Location: 001-07-0-002 04 - Extract Fans
Location: 001-07-0-003 04 - Extract Fans
Location: 001-07-0-006 04 - Extract Fans
Location: 001-07-0-011a 04 - Extract Fans
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-0-019 04 - Extract Fans
B
£0
12
0
0 0
0
2021
Vent Axia extract fan in good order.
B
£0
12
0
0 0
0
2021
Vent Axia extract fan in good order.
B
£0
12
0
0 0
0
2021
Vent Axia extract fan in good order.
£1,500
3
3
0 0
0
2012
Extract fan requires upgrading within the maintenance schedule.
B
£0
12
0
0 0
0
2021
Vent Axia extract fan in good order.
B
£0
12
0
0 0
0
2021
Vent Axia extract fan in good order.
B
£0
12
0
0 0
0
2021
Vent Axia extract fan in good order.
B
£0
12
0
0 0
0
2021
Vent Axia extract fan in good order.
B
£0
12
0
0 0
0
2021
Vent Axia extract fan in good order.
Location: 001-07-0-024 04 - Extract Fans
Location: 001-07-0-025 04 - Extract Fans
Location: 001-07-0-026 04 - Extract Fans
B(C)
Location: 001-07-0-035 04 - Extract Fans
Location: 001-07-0-037 04 - Extract Fans
Location: 001-07-0-043 04 - Extract Fans
Location: 001-07-0-057 04 - Extract Fans
Location: 001-07-0-058 04 - Extract Fans
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-0-060 04 - Extract Fans
B
£0
12
0
0 0
0
2021
Vent Axia extract fan in good order.
B
£0
12
0
0 0
0
2021
Vent Axia extract fan in good order.
B
£0
12
0
0 0
0
2021
Vent Axia extract fan in good order.
B
£0
12
0
0 0
0
2021
Vent Axia extract fan in good order.
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
Location: 001-07-0-072 04 - Extract Fans
Location: 001-07-0-077 04 - Extract Fans
Location: 001-07-0-087 04 - Extract Fans R - Engineering - Electrical
Location: 001-07-0-001
Location: 001-07-0-002 Surface fluorescent light in good order. Emergency light in good order.
Location: 001-07-0-003
Sample College Physical Condition Survey
Surface fluorescent light in good order. Lighting track in good order. Sockets and switches in good order.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-0-004 04 - Lighting Installation
C
£200
0
2
0 0
0
2009
Tungsten light requires replacement. Surface fluorescent light in good order. Sockets and switches in good order.
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
2No. surface fluorescent lights in good order. Emergency light in good order.
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
Location: 001-07-0-004a 2No. surface fluorescent lights in good order. Sockets and switches in good order.
Location: 001-07-0-004b 2No. surface fluorescent lights in good order. Sockets and switches in good order.
Location: 001-07-0-005 04 - Lighting Installation
Location: 001-07-0-006
Location: 001-07-0-007 Surface fluorescent light in good order. Lighting track in good order. Sockets and switches in good order.
Location: 001-07-0-008 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-07-0-009 Surface fluorescent light in good order. Lighting track in good order. Sockets and switches in good order.
Location: 001-07-0-010 Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-07-0-011 Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-07-0-011a 04 - Lighting Installation
Location: 001-07-0-015
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-0-016 04 - Lighting Installation
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order. Lighting track in good order. Sockets and switches in good order.
Location: 001-07-0-017 Surface fluorescent light in good order. Lighting track in good order. Sockets and switches in good order.
Location: 001-07-0-018 Surface fluorescent light in good order. Lighting track in good order. Sockets and switches in good order.
Location: 001-07-0-019 MEM distribution board in good order. Surface fluorescent light in good order.
Location: 001-07-0-020 Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-07-0-021 04 - Lighting Installation Sample College Physical Condition Survey
Surface fluorescent light in good order. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation 06 - Sockets/Switches
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
Lighting track in good order. Sockets and switches in good order.
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
B
£0
12
0
0 0
0
2021
2No. surface fluorescent lights in good order.
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
MEM distribution board in good order. Surface fluorescent light in good order. Emergency light in good order.
Location: 001-07-0-022
Location: 001-07-0-023 Surface fluorescent light in good order. Lighting track in good order. Sockets and switches in good order.
Location: 001-07-0-024 Surface fluorescent light in good order. Emergency light in good order.
Location: 001-07-0-025 04 - Lighting Installation
Location: 001-07-0-026 04 - Lighting Installation
Location: 001-07-0-027
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-0-035 04 - Lighting Installation
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order. Emergency light in good order.
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
B
£0
12
0
0 0
0
2021
Location: 001-07-0-036 04 - Lighting Installation
Location: 001-07-0-037
Location: 001-07-0-038 Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-07-0-039 Surface fluorescent light in good order. Lighting track in good order. Sockets and switches in good order.
Location: 001-07-0-040 Surface fluorescent light in good order. Lighting track in good order. Sockets and switches in good order.
Location: 001-07-0-041 04 - Lighting Installation Sample College Physical Condition Survey
Surface fluorescent light in good order. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-0-042 04 - Lighting Installation
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order. Lighting track in good order. Sockets and switches in good order.
Location: 001-07-0-043 Surface fluorescent light in good order. Emergency light in good order.
Location: 001-07-0-044 Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-07-0-045 Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-07-0-047 Surface fluorescent light in good order. Lighting track in good order. Sockets and switches in good order.
Location: 001-07-0-048 04 - Lighting Installation Sample College Physical Condition Survey
Surface fluorescent light in good order. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 05 - Emergency Lighting
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
12
0
0 0
0
2021
Emergency light in good order.
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
£200
5
3
0 0
0
2014
£0
12
0
0 0
0
2021
Location: 001-07-0-051
Location: 001-07-0-052 Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-07-0-053 Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-07-0-054 Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-07-0-055 04 - Lighting Installation
06 - Sockets/Switches
Sample College Physical Condition Survey
B(C)
B
CAT II light requires upgrading within the maintenance schedule. Sockets and switches in good order.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-0-056 04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
Lighting track in good order. Surface fluorescent light in good order. Sockets and switches in good order.
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order. Emergency light in good order.
£30,000
5
3
0 0
0
2014
Location: 001-07-0-057 Surface fluorescent light in good order. Emergency light in good order.
Location: 001-07-0-058 Surface fluorescent light in good order. Emergency light in good order.
Location: 001-07-0-059 04 - Lighting Installation
Location: 001-07-0-060
Location: 001-07-0-061 01 - Incoming Cable
B(C)
02 - Main Switchgear 03 - Distribution Boards
B B
£0 £0
30 20
0 0
0 0 0 0
0 0
2039 2029
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
Incoming cable is cloth covered and requires upgrading within the maintenance schedule. MEM switchgear in good order. MEM distribution board in good order. Surface fluorescent light in good order.
Location: 001-07-0-062 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
B
£0
12
0
0 0
0
2021
Notes
Remedial Action
3No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-07-0-063 3No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-07-0-064 3No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-07-0-065 3No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-07-0-066 MEM distribution board in good order. 2No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-07-0-067 3No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-07-0-068 04 - Lighting Installation
3No. surface fluorescent lights in good order.
Location: 001-07-0-069 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
3No. surface fluorescent lights in good order. Emergency light in good order.
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order. Sockets and switches in good order.
04 - Lighting Installation
C
£400
0
2
0 0
0
2009
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
Location: 001-07-0-070 3No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-07-0-071 MEM distribution board in good order. Surface fluorescent light in good order.
Location: 001-07-0-072 04 - Lighting Installation
Location: 001-07-0-073 04 - Lighting Installation
Location: 001-07-0-074
Location: 001-07-0-075 2No. tungsten lights require replacement. Sockets and switches in good order.
Location: 001-07-0-076
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
3No. surface fluorescent lights in good order. Emergency light in good order.
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
06 - Sockets/Switches
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
B
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
Location: 001-07-0-077 Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-07-0-078 3No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-07-0-079 3No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-07-0-080 MEM distribution board in good order. 2No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-07-0-081 04 - Lighting Installation
Location: 001-07-0-082 04 - Lighting Installation
Location: 001-07-0-083
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation
B
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£0
12
0
0 0
0
2021
Surface fluorescent light in good order.
£400
5
3
0 0
0
2014
B
£0
12
0
0 0
0
2021
2No. CAT II lights require upgrading within the maintenance schedule. Sockets and switches in good order.
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
CAT II light in good order. Sockets and switches in good order.
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
3No. surface fluorescent lights in good order. Emergency light in good order.
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
£400
5
3
0 0
0
2014
£0
12
0
0 0
0
2021
Location: 001-07-0-084 04 - Lighting Installation
06 - Sockets/Switches
B(C)
Location: 001-07-0-085 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-07-0-086
Location: 001-07-0-087 Surface fluorescent light in good order. Emergency light in good order.
Location: 001-07-0-088 3No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-07-0-089 04 - Lighting Installation
06 - Sockets/Switches
Sample College Physical Condition Survey
B(C)
B
2No. CAT II lights require upgrading within the maintenance schedule. Sockets and switches in good order.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: Lower Ground 02 - Main Switchgear 03 - Distribution Boards
B B
£0 £0
20 20
0 0
0 0 0 0
0 0
2029 2029
MEM switchgear in good order. MEM distribution board in good order. CAT II lights in good order. Surface fluorescent lights in good order. Emergency lights in good order. Sockets and switches in good order.
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
10 10
0 0
0 0 0 0
0 0
2019 2019
05 - Emergency Lighting 06 - Sockets/Switches
B B
£0 £0
10 15
0 0
0 0 0 0
0 0
2019 2024
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
V - Engineering - Fire Alarms
Location: 001-07-0-001 03 - Smoke Detectors
Location: 001-07-0-003 03 - Smoke Detectors
Location: 001-07-0-004 03 - Smoke Detectors
Location: 001-07-0-004a 03 - Smoke Detectors
Location: 001-07-0-004b 03 - Smoke Detectors
Location: 001-07-0-005 03 - Smoke Detectors
Location: 001-07-0-007 03 - Smoke Detectors
Location: 001-07-0-008 03 - Smoke Detectors Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-0-009 03 - Smoke Detectors
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
Location: 001-07-0-010 03 - Smoke Detectors
Location: 001-07-0-011 03 - Smoke Detectors
Location: 001-07-0-015 03 - Smoke Detectors
Location: 001-07-0-016 03 - Smoke Detectors
Location: 001-07-0-017 03 - Smoke Detectors
Location: 001-07-0-018 03 - Smoke Detectors
Location: 001-07-0-019 03 - Smoke Detectors
Location: 001-07-0-020 03 - Smoke Detectors
Location: 001-07-0-021 03 - Smoke Detectors
Location: 001-07-0-022 03 - Smoke Detectors
Location: 001-07-0-023 03 - Smoke Detectors Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-0-026 03 - Smoke Detectors
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
Location: 001-07-0-035 03 - Smoke Detectors
Location: 001-07-0-036 03 - Smoke Detectors
Location: 001-07-0-038 03 - Smoke Detectors
Location: 001-07-0-039 03 - Smoke Detectors
Location: 001-07-0-040 03 - Smoke Detectors
Location: 001-07-0-041 03 - Smoke Detectors
Location: 001-07-0-042 03 - Smoke Detectors
Location: 001-07-0-043 03 - Smoke Detectors
Location: 001-07-0-044 03 - Smoke Detectors
Location: 001-07-0-045 03 - Smoke Detectors
Location: 001-07-0-047 03 - Smoke Detectors Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-0-048 03 - Smoke Detectors
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
Location: 001-07-0-051 03 - Smoke Detectors
Location: 001-07-0-052 03 - Smoke Detectors
Location: 001-07-0-053 03 - Smoke Detectors
Location: 001-07-0-054 03 - Smoke Detectors
Location: 001-07-0-055 03 - Smoke Detectors
Location: 001-07-0-056 03 - Smoke Detectors
Location: 001-07-0-057 03 - Smoke Detectors
Location: 001-07-0-058 03 - Smoke Detectors
Location: 001-07-0-059 03 - Smoke Detectors
Location: 001-07-0-060 03 - Smoke Detectors
Location: 001-07-0-061 03 - Smoke Detectors Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-0-063 03 - Smoke Detectors
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
Location: 001-07-0-064 03 - Smoke Detectors
Location: 001-07-0-065 03 - Smoke Detectors
Location: 001-07-0-066 03 - Smoke Detectors
Location: 001-07-0-067 03 - Smoke Detectors
Location: 001-07-0-068 03 - Smoke Detectors
Location: 001-07-0-069 03 - Smoke Detectors
Location: 001-07-0-070 03 - Smoke Detectors
Location: 001-07-0-072 03 - Smoke Detectors
Location: 001-07-0-074 03 - Smoke Detectors
Location: 001-07-0-075 03 - Smoke Detectors
Location: 001-07-0-076 03 - Smoke Detectors Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-07-0-078 03 - Smoke Detectors
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
12
0
0 0
0
2021
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detectors in good order.
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
Sounders in good order. Call points in good order.
Location: 001-07-0-079 03 - Smoke Detectors
Location: 001-07-0-080 03 - Smoke Detectors
Location: 001-07-0-083 03 - Smoke Detectors
Location: 001-07-0-084 03 - Smoke Detectors
Location: 001-07-0-085 03 - Smoke Detectors
Location: 001-07-0-086 03 - Smoke Detectors
Location: 001-07-0-087 03 - Smoke Detectors
Location: 001-07-0-088 03 - Smoke Detectors
Location: Lower Ground 03 - Smoke Detectors
Location: Whole Block 01 - Sounders 02 - Call Points Block Total Sample College Physical Condition Survey
£177,240.00 January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Site : Sample College - 001 Block : A Hostel - 08 Facet: 1 - Building A - Building - Physical Structure
Location: Whole Block 01 - General Structure 02 - Foundations 03 - Ground Stability 05 - External Fire Escape
B B B B(C)
£0 £0 £0 £100
40 60 60 4
0 0 0 3
0 0 0 0
0 0 0 0
0 0 0 0
2049 2069 2069 2013
Brickwork: Generally sound. Generally sound. Generally sound. Cantilevered concrete staircase with a painted metal handrail: Cost allows for redecoration of metal railings.
B - Building - External Fabric
Location: Elevation 01 04 - Windows
C
£2,700
0
1
0 0
0
2009
Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 1 - 6No.
06 - Doors
B
£0
8
0
0 0
0
2017
Aluminium: Located to elevation 1.
04 - Windows
C
£4,950
0
1
0 0
0
2009
04 - Windows
B(C)
£2,300
1
2
0 0
0
2010
Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 2 - 11No. Softwood timber - Single: Replace with new located to elevation 2 - 2No.
Location: Elevation 02
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 06 - Doors
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£800
3
3
0 0
0
2012
Softwood timber: Redecorate and make good located to elevation 2 - 4No. single.
01a - Masonry - Cracking
C
£500
0
1
0 0
0
2009
02a - Cladding - Attachment
C
£800
0
1
0 0
0
2009
04 - Windows
C
£6,750
0
1
0 0
0
2009
06 - Doors
C
£1,250
0
1
0 0
0
2009
Brickwork: Evidence of cracking, with making good and monitoring for further crack expansion - located to elevation 3. Zinc sheets: 2 panels have dismounted with re-attachment and making good required. Located to elevation 3. Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 3 - 15No. Steel: Need to replace located to elevation 3 - 1No. single.
02a - Cladding - Attachment
B
£0
8
0
0 0
0
2017
04 - Windows
C
£150
0
1
0 0
0
2009
B(C)
£200
3
3
0 0
0
2012
£3,600
0
1
0 0
0
2009
Location: Elevation 03
Location: Elevation 04
06 - Doors
Softwood timber boarding: Located to elevation 4 (where extension joins original building). Aluminium - Double: Evidence that the seal has failed with making good required - located to elevation 4. Softwood timber: Redecorate and make good located to elevation 4 - 1No. single.
Location: Elevation 05 04 - Windows
Sample College Physical Condition Survey
C
Steel - Single: Replace crittal steel windows with more suitable alternative located to elevation 5 - 8No. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
04 - Windows
B(C)
£2,300
1
2
0 0
0
2010
Softwood timber - Single: Replace with new located to elevation 5 - 2No.
06 - Doors
B(C)
£200
3
3
0 0
0
2012
Softwood timber: Redecorate and make good located to elevation 5 - 1No. single.
04 - Windows
B(C)
£4,600
1
2
0 0
0
2010
04 - Windows
B(C)
£36,400
1
2
0 0
0
2010
06 - Doors
B(C)
£1,000
3
3
0 0
0
2012
Softwood timber - Single: Replace with new located to elevation 6 - 4No. Aluminium - Single: Replace with new located to elevation 6 56No. Softwood timber: Redecorate and make good located to elevation 6 - 2No. single & 2No. double.
Location: Elevation 06
Location: Whole Block 01b - Masonry - Spalling
B
£0
20
0
0 0
0
2029
Brickwork.
01c - Masonry - Pointing 01d - Masonry - Finish
B B
£0 £0
20 20
0 0
0 0 0 0
0 0
2029 2029
Brickwork. Brickwork.
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
02b - Cladding - Cracking
B
£0
6
0
0 0
0
2015
Zinc sheets.
02b - Cladding - Cracking
B
£0
8
0
0 0
0
2017
Softwood timber boarding.
02c - Cladding - Joints 02c - Cladding - Joints 02d - Cladding - Finish 02d - Cladding - Finish 04 - Windows
B B B B B
£0 £0 £0 £0 £0
6 8 6 6 6
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
2015 2017 2015 2015 2015
Zinc sheets. Softwood timber boarding. Zinc sheets. Softwood timber boarding. PVCU - Double.
B(C)
£260
1
4
0 0
0
2010
C
£250
0
2
0 0
0
2009
03 - Floor
B(C)
£350
1
3
0 0
0
2010
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
Redecoration required as part of a regular maintenance schedule. Artex ceiling: Make good and redecorate water ingress to Artex ceiling. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
C - Building - Internal Fabric
Location: 001-08-0-001 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-002 01 - Decorations
B(C)
£260
1
4
0 0
0
2010
02 - Ceiling 03 - Floor
B B(C)
£0 £350
6 1
0 3
0 0 0 0
0 0
2015 2010
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£260
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-08-0-003 01 - Decorations
02 - Ceiling 03 - Floor
B B
£0 £0
6 6
0 0
0 0 0 0
0 0
2015 2015
08 - Fixed Units
B
£0
6
0
0 0
0
2015
B(C)
£520
3
4
0 0
0
2012
02 - Ceiling
C
£100
0
3
0 0
0
2009
03 - Floor
B
£0
6
0
0 0
0
2015
£260
1
4
0 0
0
2010
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Fixed units: Kitchen units in good condition.
Location: 001-08-0-004 01 - Decorations
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Anti-slip vinyl sheet flooring: In good condition.
Location: 001-08-0-006 01 - Decorations
02 - Ceiling Sample College Physical Condition Survey
B(C)
B
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
03 - Floor
B(C)
£350
1
3
0 0
0
2010
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
01 - Decorations
B(C)
£260
1
4
0 0
0
2010
02 - Ceiling 03 - Floor
B B(C)
£0 £350
6 1
0 3
0 0 0 0
0 0
2015 2010
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
01 - Decorations
B(C)
£442
3
4
0 0
0
2012
02 - Ceiling 03 - Floor
B B(C)
£0 £595
6 1
0 3
0 0 0 0
0 0
2015 2010
B(C)
£78
3
4
0 0
0
2012
B
£0
6
0
0 0
0
2015
Notes
Remedial Action
Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-08-0-007 Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-08-0-008 Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-008a 01 - Decorations
02 - Ceiling Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
03 - Floor
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
Notes
Remedial Action
Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-08-0-009 01 - Decorations
B(C)
£260
1
4
0 0
0
2010
02 - Ceiling 03 - Floor
B B(C)
£0 £350
6 1
0 3
0 0 0 0
0 0
2015 2010
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
01 - Decorations
B(C)
£442
3
4
0 0
0
2012
02 - Ceiling 03 - Floor
B B(C)
£0 £595
6 1
0 3
0 0 0 0
0 0
2015 2010
C
£500
0
2
0 0
0
2009
B(C)
£78
3
4
0 0
0
2012
B
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-08-0-010
05 - Condition of Internal Walls
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Plaster - make good and redecorate damage to plaster walls.
Location: 001-08-0-010a 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
03 - Floor
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
Notes
Remedial Action
Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-08-0-011 01 - Decorations
B(C)
£260
1
4
0 0
0
2010
02 - Ceiling 03 - Floor
B B(C)
£0 £350
6 1
0 3
0 0 0 0
0 0
2015 2010
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
01 - Decorations
B(C)
£130
4
4
0 0
0
2013
02 - Ceiling
B(C)
£600
2
2
0 0
0
2011
03 - Floor
B(C)
£175
1
3
0 0
0
2010
B(C)
£260
1
4
0 0
0
2010
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-08-0-012 Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-013 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
03 - Floor
B(C)
£350
1
3
0 0
0
2010
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
01 - Decorations
B(C)
£260
1
4
0 0
0
2010
02 - Ceiling 03 - Floor
B B(C)
£0 £350
6 1
0 3
0 0 0 0
0 0
2015 2010
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£260
3
4
0 0
0
2012
£0
8
0
0 0
0
2017
£350
3
3
0 0
0
2012
£0
8
0
0 0
0
2017
Notes
Remedial Action
Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-08-0-014 Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-08-0-016 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-08-0-017
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Cost to B Rem Life Priority C L
R
Year
£260
3
4
0 0
0
2012
£0
8
0
0 0
0
2017
£350
3
3
0 0
0
2012
£0
8
0
0 0
0
2017
£260
3
4
0 0
0
2012
£0
8
0
0 0
0
2017
£350
3
3
0 0
0
2012
£0
8
0
0 0
0
2017
£260
3
4
0 0
0
2012
£0
8
0
0 0
0
2017
£350
3
3
0 0
0
2012
£0
8
0
0 0
0
2017
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-08-0-018 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-08-0-019 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-08-0-020 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Cost to B Rem Life Priority C L
R
Year
£260
3
4
0 0
0
2012
£0
8
0
0 0
0
2017
£350
3
3
0 0
0
2012
£0
8
0
0 0
0
2017
£260
3
4
0 0
0
2012
£0
8
0
0 0
0
2017
£350
3
3
0 0
0
2012
£0
8
0
0 0
0
2017
£260
3
4
0 0
0
2012
£0
8
0
0 0
0
2017
£350
3
3
0 0
0
2012
£0
8
0
0 0
0
2017
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-08-0-021 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-08-0-022 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-08-0-023 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
01 - Decorations
B(C)
£260
1
4
0 0
0
2010
02 - Ceiling 03 - Floor
B B(C)
£0 £350
6 1
0 3
0 0 0 0
0 0
2015 2010
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
01 - Decorations
B(C)
£260
1
4
0 0
0
2010
02 - Ceiling 03 - Floor
B B(C)
£0 £350
6 1
0 3
0 0 0 0
0 0
2015 2010
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
01 - Decorations
B(C)
£260
1
4
0 0
0
2010
02 - Ceiling 03 - Floor
B B(C)
£0 £350
6 1
0 3
0 0 0 0
0 0
2015 2010
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-08-0-024 Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-08-0-025
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 08 - Fixed Units
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£1,250
1
2
0 0
0
2010
Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
01 - Decorations
B(C)
£260
1
4
0 0
0
2010
02 - Ceiling 03 - Floor
B B(C)
£0 £350
6 1
0 3
0 0 0 0
0 0
2015 2010
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
01 - Decorations
B(C)
£156
3
4
0 0
0
2012
02 - Ceiling 03 - Floor
B B(C)
£0 £210
10 1
0 3
0 0 0 0
0 0
2019 2010
01 - Decorations
B(C)
£468
3
4
0 0
0
2012
02 - Ceiling 03 - Floor
B B(C)
£0 £630
10 1
0 3
0 0 0 0
0 0
2019 2010
Location: 001-08-0-026
Location: 001-08-0-027a Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-027b
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-027c 01 - Decorations
B(C)
£260
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
02 - Ceiling 03 - Floor
B B(C)
£0 £350
10 1
0 3
0 0 0 0
0 0
2019 2010
B(C)
£78
3
4
0 0
0
2012
B B
£0 £0
10 6
0 0
0 0 0 0
0 0
2019 2015
£1,500
2
2
0 0
0
2011
£0
6
0
0 0
0
2015
Cupboard fit for purpose.
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-08-0-027d 01 - Decorations
02 - Ceiling 03 - Floor 08 - Fixed Units
B(C)
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: Require replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-08-0-027e 12 - Comments
B
Location: 001-08-0-028 01 - Decorations
B(C)
£260
1
4
0 0
0
2010
02 - Ceiling 03 - Floor
B B(C)
£0 £350
6 1
0 3
0 0 0 0
0 0
2015 2010
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-029 01 - Decorations
02 - Ceiling
B(C)
B
£260
3
4
0 0
0
2012
£0
8
0
0 0
0
2017
03 - Floor
B(C)
£350
1
3
0 0
0
2010
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
01 - Decorations
B(C)
£260
1
4
0 0
0
2010
02 - Ceiling 03 - Floor
B B(C)
£0 £350
6 1
0 3
0 0 0 0
0 0
2015 2010
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
01 - Decorations
B(C)
£260
1
4
0 0
0
2010
02 - Ceiling 03 - Floor
B B(C)
£0 £350
6 1
0 3
0 0 0 0
0 0
2015 2010
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-08-0-030 Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-08-0-031
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 08 - Fixed Units
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£1,250
1
2
0 0
0
2010
Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
B(C)
£260
4
4
0 0
0
2013
£0
8
0
0 0
0
2017
B(C)
£350
4
3
0 0
0
2013
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£260
3
4
0 0
0
2012
£0
8
0
0 0
0
2017
£350
3
3
0 0
0
2012
£0
8
0
0 0
0
2017
Location: 001-08-0-032 01 - Decorations
02 - Ceiling 03 - Floor
B
Location: 001-08-0-033 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed unit: Sink unit in good condition.
Location: 001-08-0-034 01 - Decorations
B(C)
£260
1
4
0 0
0
2010
02 - Ceiling 03 - Floor
B B(C)
£0 £350
6 1
0 3
0 0 0 0
0 0
2015 2010
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 08 - Fixed Units
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£1,250
1
2
0 0
0
2010
Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
01 - Decorations
B(C)
£260
3
4
0 0
0
2012
02 - Ceiling 03 - Floor
B B(C)
£0 £350
10 1
0 3
0 0 0 0
0 0
2019 2010
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-08-0-034b
08 - Fixed Units
B
Location: 001-08-0-035 01 - Decorations
B(C)
£260
1
4
0 0
0
2010
02 - Ceiling 03 - Floor
B B(C)
£0 £350
6 1
0 3
0 0 0 0
0 0
2015 2010
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£260
1
4
0 0
0
2010
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-08-0-036 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
03 - Floor
B(C)
£350
1
3
0 0
0
2010
08 - Fixed Units
B(C)
£1,250
1
2
0 0
0
2010
B(C)
£260
3
4
0 0
0
2012
Notes
Remedial Action
Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit requires replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-08-0-037 01 - Decorations
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
B
£0
6
0
0 0
0
2015
Electrical Switch Room - fit for purpose.
B(C)
£130
1
4
0 0
0
2010
C
£50
0
3
0 0
0
2009
03 - Floor
B(C)
£175
2
3
0 0
0
2011
05 - Condition of Internal Walls
B(C)
£175
2
2
0 0
0
2011
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Ceramic wall tiling: Requires replacement within the maintenance schedule.
Location: 001-08-0-038 12 - Comments
Location: 001-08-0-039 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 08 - Fixed Units
B(C)
08 - Fixed Units
B
Cost to B Rem Life Priority C L
R
Year
£1,250
2
2
0 0
0
2011
£0
6
0
0 0
0
2015
£260
3
4
0 0
0
2012
Notes
Remedial Action
Fixed units: Fitted units require replacement within the maintenance schedule due to age and level of deterioration. Fixed units: Sluice in good condition.
Location: 001-08-0-040 01 - Decorations
B(C)
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
£350
2
2
0 0
0
2011
£0
10
0
0 0
0
2019
05 - Condition of Internal Walls
08 - Fixed Units
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: Requires replacement within the maintenance schedule. Sanitary fittings: In good condition.
Location: 001-08-0-041 01 - Decorations
B(C)
£312
4
4
0 0
0
2013
02 - Ceiling
B(C)
£1,440
2
2
0 0
0
2011
03 - Floor
B(C)
£420
1
3
0 0
0
2010
B(C)
£650
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-042 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
02 - Ceiling
B(C)
£1,625
4
2
0 0
0
2013
03 - Floor
B(C)
£875
1
3
0 0
0
2010
B(C)
£182
3
4
0 0
0
2012
Notes
Remedial Action
Timber panelling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-043 01 - Decorations
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
£245
2
2
0 0
0
2011
£0
10
0
0 0
0
2019
05 - Condition of Internal Walls
08 - Fixed Units
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: Requires replacement within the maintenance schedule. Sanitary fittings: In good condition.
Location: 001-08-0-044 01 - Decorations
B(C)
£442
4
4
0 0
0
2013
02 - Ceiling
B(C)
£2,040
2
2
0 0
0
2011
03 - Floor
B(C)
£595
1
3
0 0
0
2010
B(C)
£312
4
4
0 0
0
2013
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-045 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
02 - Ceiling
B(C)
£1,440
2
2
0 0
0
2011
03 - Floor
B(C)
£420
1
3
0 0
0
2010
B(C)
£208
3
4
0 0
0
2012
Notes
Remedial Action
Suspended ceiling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-046 01 - Decorations
02 - Ceiling 03 - Floor
B B
£0 £0
6 6
0 0
0 0 0 0
0 0
2015 2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
B(C)
£78
3
4
0 0
0
2012
02 - Ceiling 03 - Floor
B B
£0 £0
6 6
0 0
0 0 0 0
0 0
2015 2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£130
3
4
0 0
0
2012
£0 £0
6 6
0 0
0 0 0 0
0 0
2015 2015
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Vinyl sheet flooring: In good condition. Fixed units: Kitchen units in good condition.
Location: 001-08-0-047 01 - Decorations
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-08-0-048 01 - Decorations
02 - Ceiling 03 - Floor
Sample College Physical Condition Survey
B(C)
B B
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 08 - Fixed Units
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£1,750
3
2
0 0
0
2012
Fixed units: Laundry units require replacement within the maintenance schedule due to age and level of deterioration.
01 - Decorations
B(C)
£442
3
4
0 0
0
2012
02 - Ceiling 03 - Floor
B B(C)
£0 £595
6 1
0 3
0 0 0 0
0 0
2015 2010
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£260
3
4
0 0
0
2012
£0
6
0
0 0
0
2015
£350
3
3
0 0
0
2012
£0
6
0
0 0
0
2015
Location: 001-08-0-049
Location: 001-08-0-050 01 - Decorations
02 - Ceiling 03 - Floor
05 - Condition of Internal Walls
B B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Ceramic wall tiling: In good condition.
Location: 001-08-0-051 01 - Decorations
B(C)
£650
3
4
0 0
0
2012
02 - Ceiling
B(C)
£1,625
4
2
0 0
0
2013
03 - Floor
B(C)
£875
1
3
0 0
0
2010
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Timber panelling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-052 01 - Decorations
B(C)
£442
4
4
0 0
0
2013
02 - Ceiling
B(C)
£2,040
2
2
0 0
0
2011
03 - Floor
B(C)
£595
1
3
0 0
0
2010
01 - Decorations
C
£104
0
4
0 0
0
2009
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
10
0
0 0
0
2019
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£260
1
4
0 0
0
2010
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-053 Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-08-0-054 01 - Decorations
B(C)
02 - Ceiling
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
C
£250
0
2
0 0
0
2009
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Plaster - make good and redecorate damage to plaster walls.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 08 - Fixed Units
B
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£0
10
0
0 0
0
2019
Sanitary fittings: In good condition.
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-055 01 - Decorations
B(C)
£130
3
4
0 0
0
2012
02 - Ceiling 03 - Floor
B B(C)
£0 £175
10 4
0 3
0 0 0 0
0 0
2019 2013
01 - Decorations
B(C)
£312
4
4
0 0
0
2013
02 - Ceiling
B(C)
£1,440
2
2
0 0
0
2011
03 - Floor
B(C)
£420
1
3
0 0
0
2010
01 - Decorations
B(C)
£104
3
4
0 0
0
2012
02 - Ceiling
B(C)
£480
4
2
0 0
0
2013
03 - Floor
C
£140
0
3
0 0
0
2009
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
6
0
0 0
0
2015
Location: 001-08-0-056 Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-057
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Anti-slip vinyl sheet flooring: Requires replacement due to age and condition. Ceramic wall tiling: In good condition. Fixed units: Sink unit in good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-058 01 - Decorations
B(C)
£208
3
4
0 0
0
2012
02 - Ceiling 03 - Floor
B B(C)
£0 £280
10 2
0 3
0 0 0 0
0 0
2019 2011
08 - Fixed Units
B(C)
£2,250
5
2
0 0
0
2014
B(C)
£52
3
4
0 0
0
2012
C
£150
0
2
0 0
0
2009
B(C)
£70
2
3
0 0
0
2011
B
£0
10
0
0 0
0
2019
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Vinyl tile flooring: Requires replacement within the maintenance schedule due to age and condition. Fixed units: Kitchen units require replacement within the maintenance schedule due to age and level of deterioration.
Location: 001-08-0-059 01 - Decorations
02 - Ceiling
03 - Floor
08 - Fixed Units
Redecoration required as part of a regular maintenance schedule. Plaster ceiling: Make good and redecorate water ingress to plaster ceiling. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Sanitary fittings: In good condition.
Location: 001-08-0-060 01 - Decorations
B(C)
£104
3
4
0 0
0
2012
02 - Ceiling 03 - Floor
B B(C)
£0 £140
10 3
0 3
0 0 0 0
0 0
2019 2012
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-061 01 - Decorations
B(C)
£572
3
4
0 0
0
2012
02 - Ceiling 03 - Floor
B B(C)
£0 £770
10 3
0 3
0 0 0 0
0 0
2019 2012
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
£0
6
0
0 0
0
2015
Cupboard fit for purpose.
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-062 12 - Comments
B
Location: 001-08-0-063 01 - Decorations
B(C)
£182
3
4
0 0
0
2012
02 - Ceiling 03 - Floor
B B(C)
£0 £245
10 3
0 3
0 0 0 0
0 0
2019 2012
B(C)
£520
3
4
0 0
0
2012
02 - Ceiling
C
£100
0
3
0 0
0
2009
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
Location: 001-08-0-064 01 - Decorations
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-08-0-065 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
Cost to B Rem Life Priority C L
R
Year
B(C)
£182
3
4
0 0
0
2012
02 - Ceiling
C
£100
0
3
0 0
0
2009
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
10
0
0 0
0
2019
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-08-0-066 01 - Decorations
B(C)
£312
4
4
0 0
0
2013
02 - Ceiling
B(C)
£1,440
2
2
0 0
0
2011
03 - Floor
B(C)
£420
1
3
0 0
0
2010
01 - Decorations
B(C)
£520
3
4
0 0
0
2012
02 - Ceiling
B(C)
£1,300
4
2
0 0
0
2013
03 - Floor
B(C)
£700
1
3
0 0
0
2010
N/A
£0
0
0
0 0
0
2009
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-067 Redecoration required as part of a regular maintenance schedule. Timber panelling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-068 12 - Comments Sample College Physical Condition Survey
No Access January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-069 01 - Decorations
B(C)
£260
3
4
0 0
0
2012
02 - Ceiling
C
£100
0
3
0 0
0
2009
03 - Floor
B
£0
6
0
0 0
0
2015
£350
2
2
0 0
0
2011
£0
10
0
0 0
0
2019
05 - Condition of Internal Walls
08 - Fixed Units
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: Requires replacement within the maintenance schedule. Sanitary fittings: In good condition.
Location: 001-08-0-070 01 - Decorations
B(C)
£312
4
4
0 0
0
2013
02 - Ceiling
B(C)
£1,440
2
2
0 0
0
2011
03 - Floor
B(C)
£420
1
3
0 0
0
2010
01 - Decorations
B(C)
£312
4
4
0 0
0
2013
02 - Ceiling
B(C)
£1,440
2
2
0 0
0
2011
03 - Floor
B(C)
£420
1
3
0 0
0
2010
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-071
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-072 01 - Decorations
B(C)
£312
4
4
0 0
0
2013
02 - Ceiling
B(C)
£1,440
2
2
0 0
0
2011
03 - Floor
B(C)
£420
1
3
0 0
0
2010
B(C)
£442
3
4
0 0
0
2012
£0
8
0
0 0
0
2017
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-073 01 - Decorations
02 - Ceiling
B
02 - Ceiling 03 - Floor
B B(C)
£0 £595
10 1
0 3
0 0 0 0
0 0
2019 2010
01 - Decorations
B(C)
£520
3
4
0 0
0
2012
02 - Ceiling
B(C)
£1,300
4
2
0 0
0
2013
03 - Floor
B(C)
£700
1
3
0 0
0
2010
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-074 Redecoration required as part of a regular maintenance schedule. Timber panelling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-075
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
01 - Decorations
B(C)
£312
4
4
0 0
0
2013
02 - Ceiling
B(C)
£1,440
2
2
0 0
0
2011
03 - Floor
B(C)
£420
1
3
0 0
0
2010
01 - Decorations
B(C)
£390
3
4
0 0
0
2012
02 - Ceiling
B(C)
£1,800
2
2
0 0
0
2011
03 - Floor
B(C)
£525
5
3
0 0
0
2014
B(C)
£260
3
4
0 0
0
2012
£0
8
0
0 0
0
2017
B(C)
£350
3
3
0 0
0
2012
B(C)
£104
3
4
0 0
0
2012
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-076 Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Requires replacement within the maintenance schedule. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-101 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-102 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
02 - Ceiling
B
£0
8
0
0 0
0
2017
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
10
0
0 0
0
2019
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£104
3
4
0 0
0
2012
Notes
Remedial Action
Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-08-0-103 01 - Decorations
B(C)
02 - Ceiling
B
£0
8
0
0 0
0
2017
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
10
0
0 0
0
2019
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£260
3
4
0 0
0
2012
£0
8
0
0 0
0
2017
B(C)
£350
3
3
0 0
0
2012
B(C)
£390
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-08-0-104 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-105 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02 - Ceiling 03 - Floor
05 - Condition of Internal Walls
B
Cost to B Rem Life Priority C L
R
Year
£0
8
0
0 0
0
2017
B(C)
£525
3
3
0 0
0
2012
C
£250
0
2
0 0
0
2009
B(C)
£130
3
4
0 0
0
2012
Notes
Remedial Action
Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Plaster - make good and redecorate damage to plaster walls.
Location: 001-08-0-106 01 - Decorations
02 - Ceiling
B
£0
8
0
0 0
0
2017
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
10
0
0 0
0
2019
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£390
3
4
0 0
0
2012
£0
8
0
0 0
0
2017
B(C)
£525
3
3
0 0
0
2012
B(C)
£130
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-08-0-107 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-108 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
02 - Ceiling
B
£0
8
0
0 0
0
2017
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
10
0
0 0
0
2019
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£338
3
4
0 0
0
2012
£0
8
0
0 0
0
2017
B(C)
£455
3
3
0 0
0
2012
B(C)
£78
3
4
0 0
0
2012
02 - Ceiling
B
£0
8
0
0 0
0
2017
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
10
0
0 0
0
2019
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£260
3
4
0 0
0
2012
Notes
Remedial Action
Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-08-0-109 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-110 01 - Decorations
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-08-0-111 01 - Decorations
Sample College Physical Condition Survey
B(C)
Redecoration required as part of a regular maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02 - Ceiling
R
Year
£0
8
0
0 0
0
2017
B(C)
£350
3
3
0 0
0
2012
B(C)
£78
3
4
0 0
0
2012
02 - Ceiling
B
£0
8
0
0 0
0
2017
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
10
0
0 0
0
2019
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£260
3
4
0 0
0
2012
03 - Floor
B
Cost to B Rem Life Priority C L
Notes
Remedial Action
Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-112 01 - Decorations
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-08-0-113 01 - Decorations
B(C)
02 - Ceiling
B
£0
8
0
0 0
0
2017
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
10
0
0 0
0
2019
08 - Fixed Units
B
£0
10
0
0 0
0
2019
B(C)
£78
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-08-0-114 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02 - Ceiling 03 - Floor
B
Cost to B Rem Life Priority C L
R
Year
£0
8
0
0 0
0
2017
B(C)
£105
3
3
0 0
0
2012
B(C)
£104
3
4
0 0
0
2012
Notes
Remedial Action
Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-115 01 - Decorations
02 - Ceiling
B
£0
8
0
0 0
0
2017
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
10
0
0 0
0
2019
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£208
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-08-0-116 01 - Decorations
B(C)
02 - Ceiling
B
£0
8
0
0 0
0
2017
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
10
0
0 0
0
2019
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£260
3
4
0 0
0
2012
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-08-0-117 01 - Decorations
Sample College Physical Condition Survey
B(C)
Redecoration required as part of a regular maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02 - Ceiling 03 - Floor
B
Cost to B Rem Life Priority C L
R
Year
£0
8
0
0 0
0
2017
B(C)
£350
3
3
0 0
0
2012
B(C)
£104
3
4
0 0
0
2012
Notes
Remedial Action
Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-118 01 - Decorations
02 - Ceiling
B
£0
8
0
0 0
0
2017
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
10
0
0 0
0
2019
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£260
3
4
0 0
0
2012
£0
8
0
0 0
0
2017
B(C)
£350
3
3
0 0
0
2012
B(C)
£104
3
4
0 0
0
2012
£0
8
0
0 0
0
2017
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-08-0-119 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-0-120 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
10
0
0 0
0
2019
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£260
3
4
0 0
0
2012
£0
8
0
0 0
0
2017
£350
3
3
0 0
0
2012
B
£0
8
0
0 0
0
2017
B
£0
10
0
0 0
0
2019
£1,750
3
3
0 0
0
2012
B
£0
20
0
0 0
0
2029
B(C)
£26
3
4
0 0
0
2012
02 - Ceiling
B
£0
10
0
0 0
0
2019
03 - Floor
B
£0
8
0
0 0
0
2017
Notes
Remedial Action
Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-08-0-121 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
Location: 001-08-0-122 02 - Ceiling 03 - Floor
05 - Condition of Internal Walls
B(C)
Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fairfaced brickwork:
Location: 001-08-0-123 01 - Decorations
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-1-001 01 - Decorations
B(C)
£260
3
4
0 0
0
2012
02 - Ceiling 03 - Floor
B B(C)
£0 £350
10 3
0 3
0 0 0 0
0 0
2019 2012
£0
10
0
0 0
0
2019
08 - Fixed Units
B
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Work top in good condition.
Location: 001-08-1-002 01 - Decorations
B(C)
£260
3
4
0 0
0
2012
02 - Ceiling 03 - Floor
B B(C)
£0 £350
10 3
0 3
0 0 0 0
0 0
2019 2012
£0
10
0
0 0
0
2019
£104
3
4
0 0
0
2012
08 - Fixed Units
B
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Work top in good condition.
Location: 001-08-1-003 01 - Decorations
B(C)
02 - Ceiling 03 - Floor
B B
£0 £0
10 6
0 0
0 0 0 0
0 0
2019 2015
05 - Condition of Internal Walls
B
£0
10
0
0 0
0
2019
08 - Fixed Units
B
£0
10
0
0 0
0
2019
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-08-1-004 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
01 - Decorations
B(C)
£130
3
4
0 0
0
2012
02 - Ceiling 03 - Floor
B B(C)
£0 £175
10 3
0 3
0 0 0 0
0 0
2019 2012
Redecoration required as part of a regular maintenance schedule. Artex ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B
£0
6
0
0 0
0
2015
Stores - fit for purpose.
B
£0
6
0
0 0
0
2015
Stores - fit for purpose.
B(C)
£70
1
3
0 0
0
2010
B
£0
6
0
0 0
0
2015
Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Sanitary fittings: In good condition.
Location: 001-08-B-001 12 - Comments
Location: 001-08-B-002 12 - Comments
Location: 001-08-B-003 03 - Floor
05 - Condition of Internal Walls
Location: 001-08-B-004 01 - Decorations
B(C)
£390
3
4
0 0
0
2012
02 - Ceiling 03 - Floor
B B(C)
£0 £525
20 4
0 3
0 0 0 0
0 0
2029 2013
B(C)
£390
3
4
0 0
0
2012
£0
20
0
0 0
0
2029
Redecoration required as part of a regular maintenance schedule. Exposed Concrete Slab: Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-08-B-005 01 - Decorations
02 - Ceiling Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Exposed Concrete Slab: January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£525
4
3
0 0
0
2013
Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B
£0
6
0
0 0
0
2015
Stores - fit for purpose.
02 - Ceiling
C
£250
0
2
0 0
0
2009
12 - Comments
B
£0
6
0
0 0
0
2015
Reinforced concrete slab evidence of water ingress - due to failed utilities with further investigation required. Stores - fit for purpose.
B
£0
6
0
0 0
0
2015
Stores - fit for purpose.
02 - Ceiling
C
£250
0
2
0 0
0
2009
12 - Comments
B
£0
6
0
0 0
0
2015
Reinforced concrete slab evidence of water ingress - due to failed utilities with further investigation required. Stores - fit for purpose.
B
£0
6
0
0 0
0
2015
Stores - fit for purpose.
B B B B
£0 £0 £0 £0
6 6 10 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2015 2019 2015
B
£0
20
0
0 0
0
2029
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber.
Location: 001-08-B-006 12 - Comments
Location: 001-08-B-007
Location: 001-08-B-008 12 - Comments
Location: 001-08-B-009
Location: 001-08-B-010 12 - Comments D - Building - Roof
Location: Roof 01 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01f - Attached - Purlins 01i - Attached - Skylights
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B B
£0 £0
20 6
0 0
0 0 0 0
0 0
2029 2015
Timber. Aluminium framed glazed skylights.
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
B
£0
6
0
0 0
0
2015
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
B
£0
6
0
0 0
0
2015
Location: Roof 02 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
01h - Attached - Down Rainwater pipes
Location: Roof 03 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
01h - Attached - Down Rainwater pipes
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
Location: Roof 04 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
01h - Attached - Down Rainwater pipes
Cost to B Rem Life Priority C L
R
Year
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
B
£0
6
0
0 0
0
2015
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
B
£0
6
0
0 0
0
2015
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
Notes
Remedial Action
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
Location: Roof 05 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
01h - Attached - Down Rainwater pipes
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
Location: Roof 06 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits Sample College Physical Condition Survey
0 0 0 0
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
01h - Attached - Down Rainwater pipes
B
£0
6
0
0 0
0
2015
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
B
£0
6
0
0 0
0
2015
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
B B
£0 £0
20 20
0 0
0 0 0 0
0 0
2029 2029
Notes
Remedial Action
Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
Location: Roof 07 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
01h - Attached - Down Rainwater pipes
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
Location: Roof 08 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins
Sample College Physical Condition Survey
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
01g - Attached - Guttering
C
£1,000
0
2
0 0
0
2009
Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
01h - Attached - Down Rainwater pipes
B
£0
6
0
0 0
0
2015
B B B B
£0 £0 £0 £0
6 8 15 6
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2015 2017 2024 2015
B B C
£0 £0 £1,000
20 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2029 2029 2009
B
£0
6
0
0 0
0
2015
Concrete tiles. Mineral felt. Lead. Metal sheet coping to brick parapets. Timber. Timber. Mineral felt lined valley: Evidence of continued failures with replacement required and the implementation of a regular clearing programme. PVCU - Internal.
B B B
£0 £0 £0
6 8 6
0 0 0
0 0 0 0 0 0
0 0 0
2015 2017 2015
Mineral felt with stone chippings. Timber. Mineral felt.
B B B
£0 £0 £0
6 8 6
0 0 0
0 0 0 0 0 0
0 0 0
2015 2017 2015
Mineral felt with stone chippings. Timber. Mineral felt.
B B
£0 £0
6 8
0 0
0 0 0 0
0 0
2015 2017
Mineral felt with stone chippings. Timber.
Location: Roof 09 01a - Attached - Covering 01b - Attached - Sarking 01c - Attached - Flashing 01d - Attached - Verges/Fascias/ Soffits 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
01h - Attached - Down Rainwater pipes
Location: Roof 10 02a - Flat - Covering 02b - Flat - Decking 02c - Flat - Flashing
Location: Roof 11 02a - Flat - Covering 02b - Flat - Decking 02c - Flat - Flashing
Location: Roof 12 02a - Flat - Covering 02b - Flat - Decking Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02c - Flat - Flashing
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
6
0
0 0
0
2015
Mineral felt.
02a - Flat - Covering 02b - Flat - Decking 02c - Flat - Flashing
B B C
£0 £0 £2,500
10 20 0
0 0 2
0 0 0 0 0 0
0 0 0
2019 2029 2009
02d - Flat - Parapets
B
£0
10
0
0 0
0
2019
02h - Flat - Down Rainwater pipes
B
£0
10
0
0 0
0
2019
Mineral felt. Timber. Temporary tape: Requires replacement with a lead alternative product. Brickwork with metal sheet coping and metal tubular rails. PVCU - Internal.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£1,500
2
3
0 0
0
2011
3No. natural convectors are tired and require upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
Location: Roof 13
Facet: 2 - Engineering I - Engineering - Heating Systems
Location: 001-08-0-001 01 - Heat Emitters
Location: 001-08-0-002 01 - Heat Emitters
Location: 001-08-0-004 01 - Heat Emitters
Location: 001-08-0-006 01 - Heat Emitters
Location: 001-08-0-007 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
Location: 001-08-0-008 01 - Heat Emitters
Location: 001-08-0-008a 01 - Heat Emitters
Location: 001-08-0-009 01 - Heat Emitters
Location: 001-08-0-010 01 - Heat Emitters
Location: 001-08-0-010a 01 - Heat Emitters
Location: 001-08-0-011 01 - Heat Emitters
Location: 001-08-0-013 01 - Heat Emitters
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-014 01 - Heat Emitters
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
Location: 001-08-0-016 01 - Heat Emitters
Location: 001-08-0-017 01 - Heat Emitters
Location: 001-08-0-018 01 - Heat Emitters
Location: 001-08-0-019 01 - Heat Emitters
Location: 001-08-0-020 01 - Heat Emitters
Location: 001-08-0-021 01 - Heat Emitters
Location: 001-08-0-022
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B
£0
10
0
0 0
0
2019
Skirting heating in good order.
B
£0
10
0
0 0
0
2019
Skirting heating in good order.
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
Location: 001-08-0-023 01 - Heat Emitters
Location: 001-08-0-024 01 - Heat Emitters
Location: 001-08-0-025 01 - Heat Emitters
Location: 001-08-0-026 01 - Heat Emitters
Location: 001-08-0-027a 01 - Heat Emitters
Location: 001-08-0-027b 01 - Heat Emitters
Location: 001-08-0-028 01 - Heat Emitters
B(C)
Location: 001-08-0-029
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
£0
10
0
0 0
0
2019
Natural convector in good order.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
Location: 001-08-0-031 01 - Heat Emitters
Location: 001-08-0-032 01 - Heat Emitters
Location: 001-08-0-033 01 - Heat Emitters
Location: 001-08-0-034 01 - Heat Emitters
Location: 001-08-0-034b 01 - Heat Emitters
B
Location: 001-08-0-035 01 - Heat Emitters
Location: 001-08-0-036 01 - Heat Emitters
Location: 001-08-0-042 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£1,500
2
3
0 0
0
2011
3No. natural convectors are tired and require upgrading within the maintenance schedule.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
C
£500
0
2
0 0
0
2009
Towel rail with no low surface temperature cover requires replacement.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£1,000
2
3
0 0
0
2011
2No. natural convectors are tired and require upgrading within the maintenance schedule.
£0
20
0
0 0
0
2029
Natural convector in good order.
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
£0
10
0
0 0
0
2019
Natural convector in good order.
Location: 001-08-0-045 01 - Heat Emitters
Location: 001-08-0-047 01 - Heat Emitters
Location: 001-08-0-048 01 - Heat Emitters
Location: 001-08-0-049 01 - Heat Emitters
Location: 001-08-0-050 01 - Heat Emitters
B
Location: 001-08-0-051 01 - Heat Emitters
B(C)
Location: 001-08-0-053 01 - Heat Emitters
B
Location: 001-08-0-054 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
B
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£0
10
0
0 0
0
2019
Natural convector in good order.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
01 - Heat Emitters
B(C)
£500
2
3
0 0
0
2011
01 - Heat Emitters
B
£0
10
0
0 0
0
2019
Natural convector is tired and requires upgrading within the maintenance schedule. Skirting heating in good order.
B
£0
10
0
0 0
0
2019
Natural convector in good order.
B
£0
10
0
0 0
0
2019
Natural convector in good order.
£1,000
2
3
0 0
0
2011
2No. natural convectors are tired and require upgrading within the maintenance schedule.
£0
10
0
0 0
0
2019
Natural convector in good order.
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B(C)
£1,000
2
3
0 0
0
2011
2No. natural convectors are tired and require upgrading within the maintenance schedule.
Location: 001-08-0-056 01 - Heat Emitters
Location: 001-08-0-061
Location: 001-08-0-064 01 - Heat Emitters
Location: 001-08-0-065 01 - Heat Emitters
Location: 001-08-0-067 01 - Heat Emitters
B(C)
Location: 001-08-0-069 01 - Heat Emitters
B
Location: 001-08-0-071 01 - Heat Emitters
Location: 001-08-0-074 01 - Heat Emitters
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-076 01 - Heat Emitters
B(C)
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
Location: 001-08-0-101 01 - Heat Emitters
Location: 001-08-0-102 01 - Heat Emitters
Location: 001-08-0-103 01 - Heat Emitters
Location: 001-08-0-104 01 - Heat Emitters
Location: 001-08-0-105 01 - Heat Emitters
Location: 001-08-0-106 01 - Heat Emitters
Location: 001-08-0-107 01 - Heat Emitters
Location: 001-08-0-108 01 - Heat Emitters
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-109 01 - Heat Emitters
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
Location: 001-08-0-110 01 - Heat Emitters
Location: 001-08-0-111 01 - Heat Emitters
Location: 001-08-0-112 01 - Heat Emitters
Location: 001-08-0-113 01 - Heat Emitters
Location: 001-08-0-114 01 - Heat Emitters
Location: 001-08-0-115 01 - Heat Emitters
Location: 001-08-0-117 01 - Heat Emitters
Location: 001-08-0-118 01 - Heat Emitters
Location: 001-08-0-119 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
B
£0
15
0
0 0
0
2024
Underfloor heating in good order.
£500
2
3
0 0
0
2011
Natural convector is tired and requires upgrading within the maintenance schedule.
Underfloor heating in good order. Manifold for underfloor heating in good order.
Location: 001-08-0-120 01 - Heat Emitters
Location: 001-08-0-121 01 - Heat Emitters
B(C)
Location: 001-08-0-122 01 - Heat Emitters
B
£0
15
0
0 0
0
2024
02 - Pipework
B
£0
15
0
0 0
0
2024
B
£0
10
0
0 0
0
2019
Skirting heating in good order.
B
£0
10
0
0 0
0
2019
Skirting heating in good order.
B
£0
10
0
0 0
0
2019
Heat emitter with low surface temperature cover in good order.
B
£0
15
0
0 0
0
2024
Manifold for underfloor heating in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
Location: 001-08-1-001 01 - Heat Emitters
Location: 001-08-1-002 01 - Heat Emitters
Location: 001-08-1-003 01 - Heat Emitters L - Engineering - Medical Gases
Location: 001-08-0-122 03 - Manifolds/Outlets M - Engineering - Hot/Cold Water
Location: 001-08-0-010a 03 - Blending Valves Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-027d 03 - Blending Valves
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
C
£200
0
2
0 0
0
2009
Pipework clashes against door and requires attention.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
Location: 001-08-0-037 03 - Blending Valves
Location: 001-08-0-047 03 - Blending Valves
Location: 001-08-0-053 03 - Blending Valves
Location: 001-08-0-054 03 - Blending Valves
Location: 001-08-0-055 02 - Pipework
Location: 001-08-0-064 03 - Blending Valves
Location: 001-08-0-065 03 - Blending Valves
Location: 001-08-0-069 03 - Blending Valves
Location: 001-08-0-113 03 - Blending Valves
Location: 001-08-1-003 03 - Blending Valves O - Engineering - Main Plant Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-B-010 02 - Pumps
B
£0
15
0
0 0
0
2024
Grundfos heating pump in good order. Grundfos destrat domestic hot water service return pump in good order. ACU HM with Riello Burner calorifier in good order.
02 - Pumps
B
£0
15
0
0 0
0
2024
03 - Calorifiers
B
£0
10
0
0 0
0
2019
B
£0
10
0
0 0
0
2019
Vent Axia extract fan in good order.
B
£0
10
0
0 0
0
2019
Vent Axia extract fan in good order.
B
£0
10
0
0 0
0
2019
Vent Axia extract fan in good order.
B
£0
10
0
0 0
0
2019
Vent Axia extract fan in good order.
B
£0
10
0
0 0
0
2019
Vent Axia extract fan in good order.
B
£0
10
0
0 0
0
2019
Vent Axia extract fan in good order.
B
£0
10
0
0 0
0
2019
Vent Axia extract fan in good order.
P - Engineering - Main Plant
Location: 001-08-0-050 04 - Extract Fans
Location: 001-08-0-053 04 - Extract Fans
Location: 001-08-0-057 04 - Extract Fans
Location: 001-08-0-064 04 - Extract Fans
Location: 001-08-0-065 04 - Extract Fans
Location: 001-08-0-069 04 - Extract Fans
Location: 001-08-0-102 04 - Extract Fans Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-103 04 - Extract Fans
B
£0
10
0
0 0
0
2019
Vent Axia extract fan in good order.
B
£0
10
0
0 0
0
2019
Vent Axia extract fan in good order.
B
£0
10
0
0 0
0
2019
Vent Axia extract fan in good order.
B
£0
10
0
0 0
0
2019
Vent Axia extract fan in good order.
B
£0
10
0
0 0
0
2019
Vent Axia extract fan in good order.
B
£0
10
0
0 0
0
2019
Vent Axia extract fan in good order.
B
£0
10
0
0 0
0
2019
Vent Axia extract fan in good order.
B
£0
10
0
0 0
0
2019
Vent Axia extract fan in good order.
B
£0
10
0
0 0
0
2019
Vent Axia extract fan in good order.
Location: 001-08-0-106 04 - Extract Fans
Location: 001-08-0-108 04 - Extract Fans
Location: 001-08-0-110 04 - Extract Fans
Location: 001-08-0-112 04 - Extract Fans
Location: 001-08-0-113 04 - Extract Fans
Location: 001-08-0-115 04 - Extract Fans
Location: 001-08-0-116 04 - Extract Fans
Location: 001-08-0-118 04 - Extract Fans
Location: 001-08-0-120 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Extract Fans
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
10
0
0 0
0
2019
Vent Axia extract fan in good order.
B
£0
15
0
0 0
0
2024
Control panel in good order.
£200
5
3
0 0
0
2014
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-08-B-010 03 - Controls R - Engineering - Electrical
Location: 001-08-0-001 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
£200
5
3
0 0
0
2014
Location: 001-08-0-002 04 - Lighting Installation
B(C)
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
£200
4
3
0 0
0
2013
CAT II light requires upgrading within the maintenance schedule.
4No. surface fluorescent lights in good order. Emergency light in good order. Sockets and switches in good order.
Location: 001-08-0-003 04 - Lighting Installation
B(C)
Location: 001-08-0-004 04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting 06 - Sockets/Switches
B B
£0 £0
10 10
0 0
0 0 0 0
0 0
2019 2019
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-006 04 - Lighting Installation
B(C)
£200
5
3
0 0
0
2014
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
£200
5
3
0 0
0
2014
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-08-0-007 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
£600
3
3
0 0
0
2012
B
£0
10
0
0 0
0
2019
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
£200
5
3
0 0
0
2014
£0
10
0
0 0
0
2019
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-08-0-008 04 - Lighting Installation
06 - Sockets/Switches
B(C)
3No. surface fluorescent lights require upgrading within the maintenance schedule. Sockets and switches in good order.
Location: 001-08-0-008a Eaton William MEM distribution board in good order. 2No. surface fluorescent lights in good order.
Location: 001-08-0-009 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
Sample College Physical Condition Survey
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 06 - Sockets/Switches
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
10
0
0 0
0
2019
Sockets and switches in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
2No. surface fluorescent lights in good order. Sockets and switches in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
£200
5
3
0 0
0
2014
Location: 001-08-0-010
Location: 001-08-0-010a 2No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-08-0-011 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
£200
5
3
0 0
0
2014
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-08-0-012 Hager distribution board in good order. Surface fluorescent light in good order. Emergency light in good order.
Location: 001-08-0-013 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
Sample College Physical Condition Survey
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-014 04 - Lighting Installation
B(C)
£200
5
3
0 0
0
2014
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
£200
5
3
0 0
0
2014
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-08-0-016 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
£200
5
3
0 0
0
2014
£0
10
0
0 0
0
2019
£200
5
3
0 0
0
2014
£0
10
0
0 0
0
2019
£200
5
3
0 0
0
2014
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-08-0-017 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order.
Location: 001-08-0-018 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order.
Location: 001-08-0-019 04 - Lighting Installation
Sample College Physical Condition Survey
B(C)
Tungsten light requires upgrading within the maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
£200
5
3
0 0
0
2014
Notes
Remedial Action
Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-08-0-020 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
£200
5
3
0 0
0
2014
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-08-0-021 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
£200
4
3
0 0
0
2013
£0
10
0
0 0
0
2019
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-08-0-022 2No. surface fluorescent lights in good order. Sockets and switches in good order.
Location: 001-08-0-023 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
CAT II light requires upgrading within the maintenance schedule. Surface fluorescent light in good order.
Location: 001-08-0-024 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation
06 - Sockets/Switches
B(C)
B
Cost to B Rem Life Priority C L
R
Year
£200
5
3
0 0
0
2014
£0
10
0
0 0
0
2019
£200
5
3
0 0
0
2014
£0
10
0
0 0
0
2019
£200
5
3
0 0
0
2014
Notes
Remedial Action
Tungsten light requires upgrading within the maintenance schedule. Sockets and switches in good order.
Location: 001-08-0-025 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order.
Location: 001-08-0-026 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
£200
5
3
0 0
0
2014
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-08-0-027a Eaton William MEM distribution board in good order. Surface fluorescent light in good order.
Location: 001-08-0-027b 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
B
£0
10
0
0 0
0
2019
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order.
Location: 001-08-0-027c 04 - Lighting Installation Sample College Physical Condition Survey
Surface fluorescent light in good order. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 06 - Sockets/Switches
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
10
0
0 0
0
2019
Sockets and switches in good order.
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
B(C)
£200
5
3
0 0
0
2014
Tungsten light requires upgrading within the maintenance schedule.
04 - Lighting Installation
B(C)
£200
5
3
0 0
0
2014
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order.
£200
5
3
0 0
0
2014
Location: 001-08-0-027d 04 - Lighting Installation
Location: 001-08-0-027e 04 - Lighting Installation
Location: 001-08-0-028
Location: 001-08-0-029 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
£200
5
3
0 0
0
2014
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-08-0-030 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
Sample College Physical Condition Survey
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-031 04 - Lighting Installation
B(C)
£200
5
3
0 0
0
2014
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
£200
5
3
0 0
0
2014
£0
10
0
0 0
0
2019
£200
5
3
0 0
0
2014
£0
10
0
0 0
0
2019
£200
5
3
0 0
0
2014
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-08-0-032 2No. surface fluorescent lights in good order. Sockets and switches in good order.
Location: 001-08-0-033 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order.
Location: 001-08-0-034 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order.
Location: 001-08-0-034b 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
Sample College Physical Condition Survey
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-035 04 - Lighting Installation
B(C)
£200
5
3
0 0
0
2014
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
£200
5
3
0 0
0
2014
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-08-0-036 04 - Lighting Installation
B(C)
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
B
£0
10
0
0 0
0
2019
Emergency light in good order.
£200
5
3
0 0
0
2014
Tungsten light requires upgrading within the maintenance schedule. Surface fluorescent light in good order.
Location: 001-08--0-037 05 - Emergency Lighting
Location: 001-08-0-037 04 - Lighting Installation
B(C)
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
B
£0
10
0
0 0
0
2019
2No. surface fluorescent lights in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order. Emergency light in good order.
Location: 001-08-0-039 04 - Lighting Installation
Location: 001-08-0-040
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 06 - Sockets/Switches
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
10
0
0 0
0
2019
Sockets and switches in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
2No. surface fluorescent lights in good order. Emergency light in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting 06 - Sockets/Switches
B B
£0 £0
10 10
0 0
0 0 0 0
0 0
2019 2019
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
Location: 001-08-0-041
Location: 001-08-0-042 3No. surface fluorescent lights in good order. Emergency light in good order. Sockets and switches in good order.
Location: 001-08-0-043 2No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-08-0-044 2No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-08-0-045 Surface fluorescent light in good order. Emergency light in good order.
Location: 001-08-0-046 04 - Lighting Installation
Location: 001-08-0-047 04 - Lighting Installation Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-048 04 - Lighting Installation
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
£400
5
3
0 0
0
2014
B
£0
10
0
0 0
0
2019
2No. tungsten lights require upgrading within the maintenance schedule. Sockets and switches in good order.
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B(C)
£400
3
3
0 0
0
2012
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting 06 - Sockets/Switches
B B
£0 £0
10 10
0 0
0 0 0 0
0 0
2019 2019
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
B
£0
10
0
0 0
0
2019
Location: 001-08-0-049 04 - Lighting Installation
06 - Sockets/Switches
B(C)
Location: 001-08-0-050 Eaton William MEM distribution board in good order. 2No. surface fluorescent lights require upgrading within the maintenance schedule. Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-08-0-051 Surface fluorescent light in good order. Emergency light in good order. Sockets and switches in good order.
Location: 001-08-0-053 Surface fluorescent light in good order. Emergency light in good order.
Location: 001-08-0-054 04 - Lighting Installation
Sample College Physical Condition Survey
2No. surface fluorescent lights in good order. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 05 - Emergency Lighting
B
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£0
10
0
0 0
0
2019
Emergency light in good order.
£200
5
3
0 0
0
2014
Tungsten light requires upgrading within the maintenance schedule.
Eaton William MEM distribution board in good order. 3No. surface fluorescent lights in good order. 2No. emergency lights in good order.
Location: 001-08-0-055 04 - Lighting Installation
B(C)
Location: 001-08-0-056 03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
Eaton William MEM distribution board in good order. 2No. surface fluorescent lights in good order.
Location: 001-08-0-057 Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-08-0-058 Surface fluorescent light in good order. Sockets and switches in good order.
Location: 001-08-0-059 04 - Lighting Installation
Location: 001-08-0-060
Location: 001-08-0-061 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation
06 - Sockets/Switches
B(C)
B
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£400
5
3
0 0
0
2014
2No. tungsten lights require upgrading within the maintenance schedule. Sockets and switches in good order.
£0
10
0
0 0
0
2019
£200
5
3
0 0
0
2014
Tungsten light requires upgrading within the maintenance schedule.
3No. surface fluorescent lights in good order. Emergency light in good order.
Location: 001-08-0-063 04 - Lighting Installation
B(C)
Location: 001-08-0-064 04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
2No. surface fluorescent lights in good order. Emergency light in good order.
B
£0
10
0
0 0
0
2019
Emergency light in good order.
B
£0
10
0
0 0
0
2019
Sockets and switches in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order. Emergency light in good order.
Location: 001-08-0-065 Surface fluorescent light in good order. Emergency light in good order.
Location: 001-08-0-066
Location: 001-08-0-067 05 - Emergency Lighting
Location: 001-08-0-068 06 - Sockets/Switches
Location: 001-08-0-069
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-070 04 - Lighting Installation
B
£0
10
0
0 0
0
2019
2No. surface fluorescent lights in good order. Emergency light in good order.
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
04 - Lighting Installation
C
£400
0
2
0 0
0
2009
04 - Lighting Installation
B(C)
£400
3
3
0 0
0
2012
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
2No. surface fluorescent lights in good order. Emergency light in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
2No. surface fluorescent lights in good order. Emergency light in good order.
B B
£0 £0
10 10
0 0
0 0 0 0
0 0
2019 2019
Lighting track in good order. CAT II light in good order.
Location: 001-08-0-071 Surface fluorescent light in good order. Emergency light in good order.
Location: 001-08-0-073 2No. fluorescent lights over visual display equipment are not suitable and require upgrading. 2No. surface fluorescent lights require upgrading within the maintenance schedule. 2No. surface fluorescent lights in good order.
Location: 001-08-0-074 04 - Lighting Installation
Location: 001-08-0-075
Location: 001-08-0-076
Location: 001-08-0-101 04 - Lighting Installation 04 - Lighting Installation Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 06 - Sockets/Switches
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
10
0
0 0
0
2019
Sockets and switches in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
2No. surface fluorescent lights in good order. Sockets and switches in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
B B B
£0 £0 £0
10 10 10
0 0 0
0 0 0 0 0 0
0 0 0
2019 2019 2019
Lighting track in good order. CAT II light in good order. Sockets and switches in good order.
B B B
£0 £0 £0
10 10 10
0 0 0
0 0 0 0 0 0
0 0 0
2019 2019 2019
Lighting track in good order. CAT II light in good order. Sockets and switches in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
2No. surface fluorescent lights in good order. Sockets and switches in good order.
B B
£0 £0
10 10
0 0
0 0 0 0
0 0
2019 2019
Location: 001-08-0-102
Location: 001-08-0-103 2No. surface fluorescent lights in good order. Sockets and switches in good order.
Location: 001-08-0-104 04 - Lighting Installation 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-08-0-105 04 - Lighting Installation 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-08-0-106
Location: 001-08-0-107 04 - Lighting Installation 04 - Lighting Installation Sample College Physical Condition Survey
Lighting track in good order. CAT II light in good order. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 06 - Sockets/Switches
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
10
0
0 0
0
2019
Sockets and switches in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
2No. surface fluorescent lights in good order. Sockets and switches in good order.
04 - Lighting Installation 04 - Lighting Installation
B B
£0 £0
10 10
0 0
0 0 0 0
0 0
2019 2019
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
B B B
£0 £0 £0
10 10 10
0 0 0
0 0 0 0 0 0
0 0 0
2019 2019 2019
CAT II light in good order. Lighting track in good order. Sockets and switches in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
2No. surface fluorescent lights in good order. Sockets and switches in good order.
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
B
£0
10
0
0 0
0
2019
Lighting track in good order.
Location: 001-08-0-108
Location: 001-08-0-109 Lighting track in good order. Surface fluorescent light in good order. CAT II light in good order.
Location: 001-08-0-110 04 - Lighting Installation
Location: 001-08-0-111 04 - Lighting Installation 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-08-0-112
Location: 001-08-0-113 04 - Lighting Installation
Location: 001-08-0-114 04 - Lighting Installation Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation 06 - Sockets/Switches
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B B
£0 £0
10 10
0 0
0 0 0 0
0 0
2019 2019
CAT II light in good order. Sockets and switches in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
2No. surface fluorescent lights in good order. Sockets and switches in good order.
B
£0
10
0
0 0
0
2019
2No. surface fluorescent lights in good order.
B B B
£0 £0 £0
10 10 10
0 0 0
0 0 0 0 0 0
0 0 0
2019 2019 2019
Lighting track in good order. CAT II light in good order. Sockets and switches in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
2No. surface fluorescent lights in good order. Sockets and switches in good order.
B B B
£0 £0 £0
10 10 10
0 0 0
0 0 0 0 0 0
0 0 0
2019 2019 2019
CAT II light in good order. Lighting track in good order. Sockets and switches in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
10
0
0 0
0
2019
2No. surface fluorescent lights in good order. Sockets and switches in good order.
Location: 001-08-0-115
Location: 001-08-0-116 04 - Lighting Installation
Location: 001-08-0-117 04 - Lighting Installation 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-08-0-118
Location: 001-08-0-119 04 - Lighting Installation 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-08-0-120
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-121 04 - Lighting Installation
B(C)
£200
5
3
0 0
0
2014
04 - Lighting Installation
B(C)
£200
5
3
0 0
0
2014
B
£0
10
0
0 0
0
2019
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
B(C)
£200
5
3
0 0
0
2014
Tungsten light requires upgrading within the maintenance schedule.
B(C)
£200
5
3
0 0
0
2014
Tungsten light requires upgrading within the maintenance schedule.
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
£200
5
3
0 0
0
2014
£0
10
0
0 0
0
2019
Tungsten light requires upgrading within the maintenance schedule. Emergency light in good order.
06 - Sockets/Switches
Tungsten light requires upgrading within the maintenance schedule. CAT II light requires upgrading within the maintenance schedule. Sockets and switches in good order.
Location: 001-08-0-122 20No. surface fluorescent lights in good order. 3No. emergency lights in good order.
Location: 001-08-1-001 04 - Lighting Installation
Location: 001-08-1-002 04 - Lighting Installation
Location: 001-08-1-003 04 - Lighting Installation
B
Location: 001-08-1-004 04 - Lighting Installation
B(C)
05 - Emergency Lighting
B
V - Engineering - Fire Alarms Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-001 03 - Smoke Detectors
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
Location: 001-08-0-002 03 - Smoke Detectors
Location: 001-08-0-003 03 - Smoke Detectors
Location: 001-08-0-004 03 - Smoke Detectors
Location: 001-08-0-006 03 - Smoke Detectors
Location: 001-08-0-007 03 - Smoke Detectors
Location: 001-08-0-008 03 - Smoke Detectors
Location: 001-08-0-0089 03 - Smoke Detectors
Location: 001-08-0-008a 03 - Smoke Detectors
Location: 001-08-0-010 03 - Smoke Detectors
Location: 001-08-0-010a 03 - Smoke Detectors
Location: 001-08-0-011 03 - Smoke Detectors Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-012 03 - Smoke Detectors
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
Location: 001-08-0-013 03 - Smoke Detectors
Location: 001-08-0-014 03 - Smoke Detectors
Location: 001-08-0-016 03 - Smoke Detectors
Location: 001-08-0-017 03 - Smoke Detectors
Location: 001-08-0-018 03 - Smoke Detectors
Location: 001-08-0-019 03 - Smoke Detectors
Location: 001-08-0-020 03 - Smoke Detectors
Location: 001-08-0-021 03 - Smoke Detectors
Location: 001-08-0-022 03 - Smoke Detectors
Location: 001-08-0-023 03 - Smoke Detectors
Location: 001-08-0-024 03 - Smoke Detectors Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-025 03 - Smoke Detectors
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
Location: 001-08-0-026 03 - Smoke Detectors
Location: 001-08-0-027a 03 - Smoke Detectors
Location: 001-08-0-027b 03 - Smoke Detectors
Location: 001-08-0-027c 03 - Smoke Detectors
Location: 001-08-0-027e 03 - Smoke Detectors
Location: 001-08-0-028 03 - Smoke Detectors
Location: 001-08-0-029 03 - Smoke Detectors
Location: 001-08-0-030 03 - Smoke Detectors
Location: 001-08-0-031 03 - Smoke Detectors
Location: 001-08-0-032 03 - Smoke Detectors
Location: 001-08-0-033 03 - Smoke Detectors Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-034 03 - Smoke Detectors
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
Location: 001-08-0-034b 03 - Smoke Detectors
Location: 001-08-0-037 03 - Smoke Detectors
Location: 001-08-0-039 03 - Smoke Detectors
Location: 001-08-0-040 03 - Smoke Detectors
Location: 001-08-0-041 03 - Smoke Detectors
Location: 001-08-0-042 03 - Smoke Detectors
Location: 001-08-0-043 03 - Smoke Detectors
Location: 001-08-0-044 03 - Smoke Detectors
Location: 001-08-0-045 03 - Smoke Detectors
Location: 001-08-0-046 03 - Smoke Detectors
Location: 001-08-0-048 03 - Smoke Detectors Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-049 03 - Smoke Detectors
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
Location: 001-08-0-051 03 - Smoke Detectors
Location: 001-08-0-054 03 - Smoke Detectors
Location: 001-08-0-055 03 - Smoke Detectors
Location: 001-08-0-056 03 - Smoke Detectors
Location: 001-08-0-057 03 - Smoke Detectors
Location: 001-08-0-058 03 - Smoke Detectors
Location: 001-08-0-060 03 - Smoke Detectors
Location: 001-08-0-061 03 - Smoke Detectors
Location: 001-08-0-063 03 - Smoke Detectors
Location: 001-08-0-064 03 - Smoke Detectors
Location: 001-08-0-066 03 - Smoke Detectors Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-08-0-069 03 - Smoke Detectors
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B B
£0 £0
10 12
0 0
0 0 0 0
0 0
2019 2021
Smoke detector in good order. Fixfire main panel in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
Location: 001-08-0-070 03 - Smoke Detectors
Location: 001-08-0-071 03 - Smoke Detectors
Location: 001-08-0-073 03 - Smoke Detectors
Location: 001-08-0-074 03 - Smoke Detectors
Location: 001-08-0-075 03 - Smoke Detectors
Location: 001-08-0-076 03 - Smoke Detectors 05 - Fire Main/Zone Panel
Location: 001-08-0-101 03 - Smoke Detectors
Location: 001-08-0-104 03 - Smoke Detectors
Location: 001-08-0-105 03 - Smoke Detectors
Location: 001-08-0-107 03 - Smoke Detectors
Location: 001-08-0-109 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Smoke Detectors
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
3No. smoke detectors in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
01 - Sounders
B
£0
12
0
0 0
0
2021
02 - Call Points
B
£0
12
0
0 0
0
2021
Fire alarm sounders in good order. Fire alarm call points in good order.
Location: 001-08-0-111 03 - Smoke Detectors
Location: 001-08-0-114 03 - Smoke Detectors
Location: 001-08-0-117 03 - Smoke Detectors
Location: 001-08-0-119 03 - Smoke Detectors
Location: 001-08-0-121 03 - Smoke Detectors
Location: 001-08-0-122 03 - Smoke Detectors
Location: 001-08-1-001 03 - Smoke Detectors
Location: 001-08-1-002 03 - Smoke Detectors
Location: 001-08-1-004 03 - Smoke Detectors
Location: Whole Block
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. Block Total
Sample College Physical Condition Survey
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
ÂŁ233,072.00
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Site : Sample College - 001 Block : Learning Resources Block - 09 Facet: 1 - Building A - Building - Physical Structure
Location: Elevation 01 05 - External Fire Escape
B
£0
25
0
0 0
0
2034
Galvanised steel walk-way to first floor - located to elevation 1.
B B B
£0 £0 £0
50 70 70
0 0 0
0 0 0 0 0 0
0 0 0
2059 2079 2079
Steel frame. Generally sound. Generally sound.
B(C)
£8,750
2
2
0 0
0
2011
Aluminium - Single: Replace with new located to elevation 1 7No.
04 - Windows
B(C)
£13,750
2
2
0 0
0
2011
06 - Doors
B(C)
£2,500
3
2
0 0
0
2012
06 - Doors
B(C)
£300
4
3
0 0
0
2013
Aluminium - Single: Replace with new located to elevation 2 11No. Aluminium: Need to replace located to elevation 2 - 2No. double. Softwood timber: Redecorate and make good located to elevation 2 - 1No. double.
Location: Whole Block 01 - General Structure 02 - Foundations 03 - Ground Stability B - Building - External Fabric
Location: Elevation 01 04 - Windows
Location: Elevation 02
Location: Elevation 03
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
04 - Windows
B(C)
£6,250
2
2
0 0
0
2011
Aluminium - Single: Replace with new located to elevation 3 5No. Softwood timber: Redecorate and make good located to elevation 3 - 2No. double & 1No. single.
06 - Doors
B(C)
£800
1
3
0 0
0
2010
B(C)
£3,750
2
2
0 0
0
2011
Aluminium - Single: Replace with new located to elevation 4 3No.
B(C)
£31,250
2
2
0 0
0
2011
Aluminium - Single: Replace with new located to elevation 5 25No.
B(C)
£1,250
3
2
0 0
0
2012
Aluminium: Need to replace located to elevation 6 - 1 No double
£0 £0 £0 £0 £0 £0 £0 £0 £0
30 30 30 30 20 20 20 20 15
0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0
2039 2039 2039 2039 2029 2029 2029 2029 2024
Brickwork. Brickwork. Brickwork. Brickwork. Zinc sheet. Zinc sheet. Zinc sheet. Zinc sheet. Aluminium.
Location: Elevation 04 04 - Windows
Location: Elevation 05 04 - Windows
Location: Elevation 06 06 - Doors
Location: Whole Block 01a - Masonry - Cracking 01b - Masonry - Spalling 01c - Masonry - Pointing 01d - Masonry - Finish 02a - Cladding - Attachment 02b - Cladding - Cracking 02c - Cladding - Joints 02d - Cladding - Finish 06 - Doors
B B B B B B B B B
0 0 0 0 0 0 0 0 0
C - Building - Internal Fabric
Location: 001-09-0-001 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
£416
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£560
5
3
0 0
0
2014
B(C)
£1,300
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£1,750
5
3
0 0
0
2014
B(C)
£624
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£840
5
3
0 0
0
2014
B(C)
£624
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-0-002 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-0-003 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-0-004 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£840
5
3
0 0
0
2014
Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
B(C)
£416
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£560
5
3
0 0
0
2014
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
B(C)
£416
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£560
5
3
0 0
0
2014
N/A
£0
0
0
0 0
0
2009
Under refurbishment.
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls 08 - Fixed Units
B B
£0 £0
10 20
0 0
0 0 0 0
0 0
2019 2029
Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Plastic walls: In good condition. Fixed units: Steel kitchen units in good condition.
Location: 001-09-0-005 01 - Decorations
02 - Ceiling 03 - Floor
B
Location: 001-09-0-006 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-0-007 12 - Comments
Location: 001-09-0-012
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-09-0-012a 02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
10
0
0 0
0
2019
£624
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£840
5
3
0 0
0
2014
B(C)
£520
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£700
5
3
0 0
0
2014
B(C)
£624
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Plastic walls: In good condition.
Location: 001-09-0-013 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-0-014 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-0-015 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£840
5
3
0 0
0
2014
Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
B(C)
£1,040
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
£1,400
5
3
0 0
0
2014
£0
15
0
0 0
0
2024
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. Fixed units: Sink unit in good condition.
£1,664
5
4
0 0
0
2014
Location: 001-09-0-016 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B B(C)
B
Location: 001-09-0-017 01 - Decorations
B(C)
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
8
0
0 0
0
2017
£1,300
4
4
0 0
0
2013
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition.
Location: 001-09-0-018 01 - Decorations
B(C)
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Vinyl sheet flooring: In good condition.
Location: 001-09-0-019
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
B(C)
Cost to B Rem Life Priority C L
R
Year
£208
4
4
0 0
0
2013
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
6
0
0 0
0
2015
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Vinyl sheet flooring: In good condition.
Location: 001-09-0-020 01 - Decorations
B(C)
£520
4
4
0 0
0
2013
02 - Ceiling 03 - Floor
B B(C)
£0 £700
40 1
0 3
0 0 0 0
0 0
2049 2010
Redecoration required as part of a regular maintenance schedule. Concrete decking: Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition.
N/A
£0
0
0
0 0
0
2009
Cupboard under stairs.
B(C)
£312
5
4
0 0
0
2014
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Vinyl sheet flooring: In good condition.
Location: 001-09-0-021 12 - Comments
Location: 001-09-0-022 01 - Decorations
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
8
0
0 0
0
2017
£416
4
4
0 0
0
2013
Location: 001-09-0-023 01 - Decorations
B(C)
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
8
0
0 0
0
2017
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 08 - Fixed Units
B
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£0
15
0
0 0
0
2024
Sanitary fittings: In good condition.
£312
4
4
0 0
0
2013
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-09-0-024 01 - Decorations
B(C)
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
15
0
0 0
0
2024
£780
4
4
0 0
0
2013
£0
15
0
0 0
0
2024
B(C)
£1,050
4
3
0 0
0
2013
B(C)
£780
4
4
0 0
0
2013
£0
15
0
0 0
0
2024
£1,050
4
3
0 0
0
2013
Location: 001-09-0-025 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Concrete with applied finish: Is in poor condition and requires making good within the maintenance schedule.
Location: 001-09-0-026 01 - Decorations
02 - Ceiling 03 - Floor
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Concrete with applied finish: Is in poor condition and requires making good within the maintenance schedule.
Location: 001-09-0-027
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
B(C)
Cost to B Rem Life Priority C L
R
Year
£520
5
4
0 0
0
2014
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
15
0
0 0
0
2024
£520
5
4
0 0
0
2014
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-09-0-028 01 - Decorations
B(C)
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
15
0
0 0
0
2024
£104
5
4
0 0
0
2014
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-09-0-029 01 - Decorations
B(C)
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
15
0
0 0
0
2024
£104
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-09-0-030 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
15
0
0 0
0
2024
£3,120
5
4
0 0
0
2014
Notes
Remedial Action
Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-09-0-031 01 - Decorations
B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Timber flooring: In good condition. Vinyl sheet flooring: In good condition.
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
6
0
0 0
0
2015
03 - Floor
B
£0
8
0
0 0
0
2017
N/A
£0
0
0
0 0
0
2009
No Access
B(C)
£416
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£560
5
3
0 0
0
2014
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£208
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
Location: 001-09-1-001 12 - Comments
Location: 001-09-1-002 01 - Decorations
02 - Ceiling 03 - Floor
B
Location: 001-09-1-003 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£280
5
3
0 0
0
2014
Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£624
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£840
5
3
0 0
0
2014
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£1,560
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£2,100
5
3
0 0
0
2014
B(C)
£1,560
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
£2,100
5
3
0 0
0
2014
Location: 001-09-1-004 01 - Decorations
02 - Ceiling 03 - Floor
B
Location: 001-09-1-005 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-1-006 01 - Decorations
02 - Ceiling 03 - Floor
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-1-007 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
£1,560
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£2,100
5
3
0 0
0
2014
B(C)
£1,560
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£2,100
5
3
0 0
0
2014
B(C)
£4,160
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£5,600
5
3
0 0
0
2014
B(C)
£520
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-1-008 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-1-009 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-1-010 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£700
5
3
0 0
0
2014
Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£2,080
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£2,800
5
3
0 0
0
2014
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£624
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£840
5
3
0 0
0
2014
B(C)
£780
4
4
0 0
0
2013
Location: 001-09-1-011 01 - Decorations
02 - Ceiling 03 - Floor
B
Location: 001-09-1-012 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-1-013 01 - Decorations
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Concrete with applied finish: In good condition.
Location: 001-09-1-014
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
B(C)
Cost to B Rem Life Priority C L
R
Year
£416
4
4
0 0
0
2013
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
8
0
0 0
0
2017
£780
4
4
0 0
0
2013
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Vinyl sheet flooring: In good condition.
Location: 001-09-1-015 01 - Decorations
B(C)
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
8
0
0 0
0
2017
£780
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£1,050
5
3
0 0
0
2014
B(C)
£416
4
4
0 0
0
2013
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Vinyl sheet flooring: In good condition.
Location: 001-09-1-016 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-1-017 01 - Decorations
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Concrete with applied finish: In good condition.
Location: 001-09-1-018 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
B(C)
Cost to B Rem Life Priority C L
R
Year
£416
4
4
0 0
0
2013
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
6
0
0 0
0
2015
£624
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£840
5
3
0 0
0
2014
B(C)
£156
4
4
0 0
0
2013
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Concrete with applied finish: In good condition.
Location: 001-09-1-019 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-1-020 01 - Decorations
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
6
0
0 0
0
2015
08 - Fixed Units
B
£0
12
0
0 0
0
2021
£624
5
4
0 0
0
2014
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Fixed units: Belfast sink unit in good condition.
Location: 001-09-1-021 01 - Decorations
B(C)
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
8
0
0 0
0
2017
Sample College Physical Condition Survey
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 08 - Fixed Units
B
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
£0
15
0
0 0
0
2024
Sanitary fittings: In good condition.
£416
5
4
0 0
0
2014
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-09-1-022 01 - Decorations
B(C)
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
15
0
0 0
0
2024
£416
5
4
0 0
0
2014
Location: 001-09-1-023 01 - Decorations
B(C)
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
15
0
0 0
0
2024
£208
5
4
0 0
0
2014
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-09-1-024 01 - Decorations
B(C)
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
15
0
0 0
0
2024
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-09-1-025 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
B(C)
Cost to B Rem Life Priority C L
R
Year
£208
5
4
0 0
0
2014
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
15
0
0 0
0
2024
£1,300
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£1,750
5
3
0 0
0
2014
B(C)
£624
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£840
5
3
0 0
0
2014
B(C)
£728
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-09-2-000 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-2-001 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-2-002 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£980
5
3
0 0
0
2014
Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£728
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£980
5
3
0 0
0
2014
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£728
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£980
5
3
0 0
0
2014
B(C)
£728
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
£980
5
3
0 0
0
2014
Location: 001-09-2-003 01 - Decorations
02 - Ceiling 03 - Floor
B
Location: 001-09-2-004 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-2-005 01 - Decorations
02 - Ceiling 03 - Floor
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-2-006 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
£624
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£840
5
3
0 0
0
2014
B(C)
£624
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£840
5
3
0 0
0
2014
B(C)
£1,560
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£2,100
5
3
0 0
0
2014
B(C)
£1,300
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-2-007 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-2-008 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-2-009 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£1,750
5
3
0 0
0
2014
Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£884
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£1,190
5
3
0 0
0
2014
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£884
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£1,190
5
3
0 0
0
2014
B(C)
£1,300
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
£1,750
5
3
0 0
0
2014
Location: 001-09-2-010 01 - Decorations
02 - Ceiling 03 - Floor
B
Location: 001-09-2-011 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-2-012 01 - Decorations
02 - Ceiling 03 - Floor
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-2-013 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
£1,820
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£2,450
5
3
0 0
0
2014
B(C)
£416
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£560
5
3
0 0
0
2014
B(C)
£624
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£840
5
3
0 0
0
2014
B(C)
£1,300
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-2-014 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-2-015 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-2-016 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£1,750
5
3
0 0
0
2014
Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
B(C)
£416
5
4
0 0
0
2014
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Fixed units: Kitchen units in good condition.
Location: 001-09-2-017 01 - Decorations
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
15
0
0 0
0
2024
£780
4
4
0 0
0
2013
Location: 001-09-2-018 01 - Decorations
B(C)
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
6
0
0 0
0
2015
£416
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
£560
5
3
0 0
0
2014
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Concrete with applied finish: In good condition.
Location: 001-09-2-019 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
B B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-2-020
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
Cost to B Rem Life Priority C L
R
Year
£780
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£1,050
5
3
0 0
0
2014
B(C)
£1,300
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£1,750
5
3
0 0
0
2014
B(C)
£156
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B(C)
£210
5
3
0 0
0
2014
B(C)
£624
5
4
0 0
0
2014
£0
15
0
0 0
0
2024
B
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-2-021 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-2-022 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet: Requires replacement with contract quality carpet within the maintenance schedule.
Location: 001-09-2-023 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
C
£840
0
3
0 0
0
2009
Concrete with applied finish: requires re-application of finish
B(C)
£52
5
4
0 0
0
2014
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
15
0
0 0
0
2024
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Fixed units: Belfast sink unit in good condition.
£416
5
4
0 0
0
2014
Location: 001-09-2-024 01 - Decorations
Location: 001-09-2-025 01 - Decorations
B(C)
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
15
0
0 0
0
2024
£416
5
4
0 0
0
2014
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-09-2-026 01 - Decorations
B(C)
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
15
0
0 0
0
2024
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
Location: 001-09-2-027 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Decorations
B(C)
Cost to B Rem Life Priority C L
R
Year
£156
5
4
0 0
0
2014
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
8
0
0 0
0
2017
08 - Fixed Units
B
£0
15
0
0 0
0
2024
01a - Attached - Covering
C
£10,000
0
1
0 0
0
2009
01b - Attached - Sarking 01c - Attached - Flashing
B C
£0 £400
10 0
0 1
0 0 0 0
0 0
2019 2009
01e - Attached - Rafters
B
£0
50
0
0 0
0
2059
01f - Attached - Purlins 01g - Attached - Guttering 01h - Attached - Down Rainwater pipes
B B C
£0 £0 £5,000
50 6 0
0 0 3
0 0 0 0 0 0
0 0 0
2059 2015 2009
Notes
Remedial Action
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Sanitary fittings: In good condition.
D - Building - Roof
Location: Roof 01
Sample College Physical Condition Survey
Clay tiles: Evidence of slipped & broken tiles with localised replacement required. Mineral felt. Lead: Appears to have been subject to theft with localised replacement and making good required. Located to plant room door surround. Metal.
Timber. Parapet gutters: Felt lined. Cast iron: Require redecoration and making good.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01i - Attached - Skylights
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
C
£32,300
0
1
0 0
0
2009
Aluminium/timber Velux: In very poor condition with windows currently screwed shut complete replacement required - 38No.
B B B
£0 £0 £0
15 25 15
0 0 0
0 0 0 0 0 0
0 0 0
2024 2034 2024
Single ply membrane. Timber. Polycarbonate domed skylights.
02a - Flat - Covering 02b - Flat - Decking 02h - Flat - Down Rainwater pipes
B B C
£0 £0 £2,000
6 15 0
0 0 3
0 0 0 0 0 0
0 0 0
2015 2024 2009
02i - Flat - Skylights
B
£0
6
0
0 0
0
2015
Mineral felt with stone chippings. Timber. Cast iron: Require redecoration and making good. Steel and aluminium framed glazed lantern light.
02a - Flat - Covering
B
£0
6
0
0 0
0
2015
02b - Flat - Decking
B
£0
10
0
0 0
0
2019
02h - Flat - Down Rainwater pipes
C
£100
0
3
0 0
0
2009
Location: Roof 02 02a - Flat - Covering 02b - Flat - Decking 02i - Flat - Skylights
Location: Roof 03
Location: Roof 04 Mineral felt (assumed condition, no access). Timber.
Cast iron: Require redecoration and making good.
G - Building - Gardens
Location: External Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Other Structure (specify)
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
C
£600
0
3
0 0
0
2009
Steel framed tank room with clay tile cladding and a single ply membrane flat roof: The timber doors are in poor condition and require making good.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
Facet: 2 - Engineering I - Engineering - Heating Systems
Location: 001-09-0-001 01 - Heat Emitters
Location: 001-09-0-002 01 - Heat Emitters
Location: 001-09-0-003 01 - Heat Emitters
Location: 001-09-0-004 01 - Heat Emitters
Location: 001-09-0-005 01 - Heat Emitters
Location: 001-09-0-006 01 - Heat Emitters
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-09-0-013 01 - Heat Emitters
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
2No. heat emitters with low surface temperature covers in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
Location: 001-09-0-014 01 - Heat Emitters
Location: 001-09-0-015 01 - Heat Emitters
Location: 001-09-0-016 01 - Heat Emitters
Location: 001-09-0-017 01 - Heat Emitters
Location: 001-09-0-018 01 - Heat Emitters
Location: 001-09-0-020 01 - Heat Emitters
Location: 001-09-0-022
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
2No. heat emitters with low surface temperature covers in good order.
Location: 001-09-0-023 01 - Heat Emitters
Location: 001-09-0-024 01 - Heat Emitters
Location: 001-09-0-025 01 - Heat Emitters
Location: 001-09-0-026 01 - Heat Emitters
Location: 001-09-0-027 01 - Heat Emitters
Location: 001-09-0-028 01 - Heat Emitters
Location: 001-09-0-031 01 - Heat Emitters
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-09-1-002 01 - Heat Emitters
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
Location: 001-09-1-003 01 - Heat Emitters
Location: 001-09-1-004 01 - Heat Emitters
Location: 001-09-1-005 01 - Heat Emitters
Location: 001-09-1-006 01 - Heat Emitters
Location: 001-09-1-007 01 - Heat Emitters
Location: 001-09-1-008 01 - Heat Emitters
Location: 001-09-1-009
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
Location: 001-09-1-013 01 - Heat Emitters
Location: 001-09-1-015 01 - Heat Emitters
Location: 001-09-1-015A 01 - Heat Emitters
Location: 001-09-1-019 01 - Heat Emitters
Location: 001-09-1-021 01 - Heat Emitters
Location: 001-09-1-022 01 - Heat Emitters
Location: 001-09-1-024 01 - Heat Emitters
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-09-1-025 01 - Heat Emitters
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
2No. heat emitters with low surface temperature covers in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
Location: 001-09-2-000 01 - Heat Emitters
Location: 001-09-2-001 01 - Heat Emitters
Location: 001-09-2-002 01 - Heat Emitters
Location: 001-09-2-003 01 - Heat Emitters
Location: 001-09-2-004 01 - Heat Emitters
Location: 001-09-2-005 01 - Heat Emitters
Location: 001-09-2-006
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
2No. heat emitters with low surface temperature covers in good order.
Location: 001-09-2-007 01 - Heat Emitters
Location: 001-09-2-008 01 - Heat Emitters
Location: 001-09-2-009 01 - Heat Emitters
Location: 001-09-2-010 01 - Heat Emitters
Location: 001-09-2-011 01 - Heat Emitters
Location: 001-09-2-012 01 - Heat Emitters
Location: 001-09-2-013 01 - Heat Emitters
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-09-2-014 01 - Heat Emitters
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
Location: 001-09-2-015 01 - Heat Emitters
Location: 001-09-2-016 01 - Heat Emitters
Location: 001-09-2-018 01 - Heat Emitters
Location: 001-09-2-020 01 - Heat Emitters
Location: 001-09-2-023 01 - Heat Emitters
Location: 001-09-2-025 01 - Heat Emitters
Location: 001-09-2-026
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - Heat Emitters
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Heat emitter with low surface temperature cover in good order.
B
£0
20
0
0 0
0
2029
Cooker hood in good order.
B
£0
10
0
0 0
0
2019
Grille in good order.
B
£0
10
0
0 0
0
2019
Grille in good order.
B
£0
10
0
0 0
0
2019
Grille in good order.
B
£0
10
0
0 0
0
2019
Grille in good order.
B
£0
12
0
0 0
0
2021
Daikin split unit in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
Location: 001-09-2-027 01 - Heat Emitters
K - Engineering - Vent & Air Con
Location: 001-09-0-012 03 - Grilles & Diffusers
Location: 001-09-0-024 03 - Grilles & Diffusers
Location: 001-09-0-025 03 - Grilles & Diffusers
Location: 001-09-0-029 03 - Grilles & Diffusers
Location: 001-09-0-030 03 - Grilles & Diffusers
Location: 001-09-1-001 05 - Cooling Units M - Engineering - Hot/Cold Water
Location: 001-09-0-029 03 - Blending Valves
Location: 001-09-0-030 03 - Blending Valves
Location: 001-09-1-024 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Blending Valves
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
10
0
0 0
0
2019
Blending valve in good order.
B
£0
15
0
0 0
0
2024
Lift hydrant in good order.
£80,000
4
3
0 0
0
2013
Lift is very poor and will need upgrading within the maintenance schedule.
2No. Grundfos twinhead domestic hot water service pumps in good order. Grundfos heating pumps in good order. Pre insulated 400 litre cylinder with no destrat pump needs destratification pump fitting. Mikrofill pressurisation unit in good order.
Location: 001-09-1-025 03 - Blending Valves
Location: 001-09-2-027 03 - Blending Valves N - Engineering - Lifts
Location: 001-09-2-023A 02 - Comments
Location: 001-09-2-026 01 - Lifts
B(C)
O - Engineering - Main Plant
Location: 001-09-0-026A 02 - Pumps
B
£0
19
0
0 0
0
2028
02 - Pumps
B
£0
19
0
0 0
0
2028
03 - Calorifiers
C
£1,000
0
2
0 0
0
2009
05 - Pressurisation Units
B
£0
19
0
0 0
0
2028
B
£0
19
0
0 0
0
2028
Location: 001-09-0-26A 01 - Heating Boilers
3No. Wessex Modumax 120 heating boiler in good order.
P - Engineering - Lightning Protection
Location: Exterior Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01 - System
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
C
£1,000
0
2
0 0
0
2009
Earth bonding is missing.
B
£0
10
0
0 0
0
2019
Control panel in good order.
C
£10,000
0
2
0 0
0
2009
Dale generator has seen better days, manufactured in 1980.
B
£0
10
0
0 0
0
2019
Lift hydraulic gear panel in good order.
B
£0
19
0
0 0
0
2028
Control panel as new.
B
£0
12
0
0 0
0
2021
Box fan in good order.
B
£0
10
0
0 0
0
2019
Kitchen extract in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
P - Engineering - Main Plant
Location: 001-09-0-012 03 - Controls
Location: 001-09-0-019B 08 - Generators
Location: 001-09-0-025A 03 - Controls
Location: 001-09-0-026A 03 - Controls
Location: 001-09-1-001 04 - Extract Fans
Location: 001-Exterior 04 - Extract Fans R - Engineering - Electrical
Location: 001-09-0-001 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-0-002 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation 06 - Sockets/Switches
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
20 10
0 0
0 0 0 0
0 0
2029 2019
Distribution board in good order. Surface fluorescent light in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order. Emergency light in good order.
B
£0
10
0
0 0
0
2019
Location: 001-09-0-003 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-0-004 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-0-005 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-0-006 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-0-007 03 - Distribution Boards 04 - Lighting Installation
Location: 001-09-0-012
Location: 001-09-0-012A 04 - Lighting Installation Sample College Physical Condition Survey
Surface fluorescent light in good order. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-09-0-013 04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
20
0
0 0
0
2029
Surface fluorescent light in good order. Sockets and switches in good order.
B B
£0 £0
20 12
0 0
0 0 0 0
0 0
2029 2021
Distribution board in good order. CAT II light in good order.
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
2No. CAT II lights in good order. Emergency light in good order.
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B
£0
12
0
0 0
0
2021
Location: 001-09-0-014 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-0-015 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-0-016
Location: 001-09-0-017 03 - Distribution Boards 04 - Lighting Installation
Location: 001-09-0-018
Location: 001-09-0-018A 2No. distribution boards in good order. CAT II light in good order.
Location: 001-09-0-018B Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
12
0
0 0
0
2021
CAT II light in good order.
B B
£0 £0
12 10
0 0
0 0 0 0
0 0
2021 2019
CAT II light in good order. Emergency light in good order.
B
£0
20
0
0 0
0
2029
Surface fluorescent light in good order.
B
£0
20
0
0 0
0
2029
Surface fluorescent light in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B
£0
10
0
0 0
0
2019
2No. surface fluorescent lights in good order.
B
£0
10
0
0 0
0
2019
2No. surface fluorescent lights in good order.
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
B B
£0 £0
12 10
0 0
0 0 0 0
0 0
2021 2019
CAT II light in good order. Emergency light in good order.
Location: 001-09-0-019A 04 - Lighting Installation 05 - Emergency Lighting
Location: 001-09-0-020 04 - Lighting Installation
Location: 001-09-0-021 04 - Lighting Installation
Location: 001-09-0-022 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-0-022A 04 - Lighting Installation
Location: 001-09-0-023 04 - Lighting Installation
Location: 001-09-0-024 04 - Lighting Installation
Location: 001-09-0-025 04 - Lighting Installation 05 - Emergency Lighting
Location: 001-09-0-025A Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
B B
£0 £0
12 10
0 0
0 0 0 0
0 0
2021 2019
CAT II light in good order. Emergency light in good order.
B
£0
14
0
0 0
0
2023
Lights in good order.
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
06 - Sockets/Switches
B
£0
20
0
0 0
0
2029
Surface fluorescent light in good order. Sockets and switches in good order.
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
Location: 001-09-0-026 04 - Lighting Installation 05 - Emergency Lighting
Location: 001-09-0-026A 04 - Lighting Installation
Location: 001-09-0-027 04 - Lighting Installation
Location: 001-09-0-028 04 - Lighting Installation
Location: 001-09-0-029 04 - Lighting Installation
Location: 001-09-0-030 04 - Lighting Installation
Location: 001-09-0-031
Location: 001-09-1-001
Sample College Physical Condition Survey
MEM distribution board in good order. Surface fluorescent light in good order. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-09-1-002 04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
Location: 001-09-1-003 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-1-004 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-1-005 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-1-006 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-1-007 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-1-008 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-1-009 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation 05 - Emergency Lighting 06 - Sockets/Switches
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B B B
£0 £0 £0
12 10 20
0 0 0
0 0 0 0 0 0
0 0 0
2021 2019 2029
CAT II light in good order. Emergency light in good order. Sockets and switches in good order.
B B
£0 £0
20 10
0 0
0 0 0 0
0 0
2029 2019
3No. distribution boards Surface fluorescent light in good order.
B
£0
12
0
0 0
0
2021
CAT II light in good order.
B B
£0 £0
12 10
0 0
0 0 0 0
0 0
2021 2019
CAT II light in good order. Emergency light in good order.
B B
£0 £0
12 10
0 0
0 0 0 0
0 0
2021 2019
CAT II light in good order. Emergency light in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B
£0
12
0
0 0
0
2021
CAT II light in good order.
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order. Emergency light in good order.
Location: 001-09-1-012 03 - Distribution Boards 04 - Lighting Installation
Location: 001-09-1-013 04 - Lighting Installation
Location: 001-09-1-014 04 - Lighting Installation 05 - Emergency Lighting
Location: 001-09-1-015 04 - Lighting Installation 05 - Emergency Lighting
Location: 001-09-1-015A 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-1-016 04 - Lighting Installation
Location: 001-09-1-018
Location: 001-09-1-019
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order. Emergency light in good order.
05 - Emergency Lighting
B
£0
10
0
0 0
0
2019
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
01 - Incoming Cable 02 - Main Switchgear
B B
£0 £0
25 25
0 0
0 0 0 0
0 0
2034 2034
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
Incoming cable in good order. Minofrm switchgear in good order. Surface fluorescent light in good order.
03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B
£0
12
0
0 0
0
2021
CAT II light in good order.
Location: 001-09-1-020 04 - Lighting Installation
Location: 001-09-1-021 04 - Lighting Installation
Location: 001-09-1-024 04 - Lighting Installation
Location: 001-09-1-025
Location: 001-09-1-026 MEM distribution board in good order. Surface fluorescent light in good order.
Location: 001-09-2-000 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-2-001 04 - Lighting Installation
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 06 - Sockets/Switches
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
20
0
0 0
0
2029
Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
Location: 001-09-2-002 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-2-003 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-2-004 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-2-005 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-2-006 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-2-007 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-2-008 04 - Lighting Installation 06 - Sockets/Switches Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-09-2-009 04 - Lighting Installation 06 - Sockets/Switches
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
Location: 001-09-2-010 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-2-011 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-2-012 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-2-013 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-2-014 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-2-015 04 - Lighting Installation 06 - Sockets/Switches
Location: 001-09-2-016 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 04 - Lighting Installation 06 - Sockets/Switches
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B B
£0 £0
12 20
0 0
0 0 0 0
0 0
2021 2029
CAT II light in good order. Sockets and switches in good order.
03 - Distribution Boards 04 - Lighting Installation
B B
£0 £0
20 10
0 0
0 0 0 0
0 0
2029 2019
06 - Sockets/Switches
B
£0
20
0
0 0
0
2029
Distribution board in good order. 2No. surface fluorescent lights in good order. Sockets and switches in good order.
B
£0
12
0
0 0
0
2021
CAT II light in good order.
B
£0
12
0
0 0
0
2021
CAT II light in good order.
B
£0
12
0
0 0
0
2021
CAT II light in good order.
B B
£0 £0
12 10
0 0
0 0 0 0
0 0
2021 2019
CAT II light in good order. Emergency light in good order.
B B
£0 £0
12 10
0 0
0 0 0 0
0 0
2021 2019
CAT II light in good order. Emergency light in good order.
B
£0
10
0
0 0
0
2019
2No. surface fluorescent lights in good order.
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
Location: 001-09-2-017
Location: 001-09-2-018 04 - Lighting Installation
Location: 001-09-2-019 04 - Lighting Installation
Location: 001-09-2-020 04 - Lighting Installation
Location: 001-09-2-021 04 - Lighting Installation 05 - Emergency Lighting
Location: 001-09-2-022 04 - Lighting Installation 05 - Emergency Lighting
Location: 001-09-2-023 04 - Lighting Installation
Location: 001-09-2-024 04 - Lighting Installation
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-09-2-025 04 - Lighting Installation
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
B
£0
10
0
0 0
0
2019
Surface fluorescent light in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
Location: 001-09-2-026 04 - Lighting Installation
Location: 001-09-2-027 04 - Lighting Installation V - Engineering - Fire Alarms
Location: 001-09-0-001 03 - Smoke Detectors
Location: 001-09-0-002 03 - Smoke Detectors
Location: 001-09-0-003 03 - Smoke Detectors
Location: 001-09-0-004 03 - Smoke Detectors
Location: 001-09-0-005 03 - Smoke Detectors
Location: 001-09-0-006 03 - Smoke Detectors
Location: 001-09-0-007 03 - Smoke Detectors
Location: 001-09-0-012 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Smoke Detectors
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
2No. smoke detectors in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Fire alarm panel in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
Location: 001-09-0-013 03 - Smoke Detectors
Location: 001-09-0-014 03 - Smoke Detectors
Location: 001-09-0-015 03 - Smoke Detectors
Location: 001-09-0-016 03 - Smoke Detectors
Location: 001-09-0-017 03 - Smoke Detectors
Location: 001-09-0-018 03 - Smoke Detectors
Location: 001-09-0-018A 03 - Smoke Detectors
Location: 001-09-0-018B 03 - Smoke Detectors
Location: 001-09-0-019A 03 - Smoke Detectors
Location: 001-09-0-020 05 - Fire Main/Zone Panel
Location: 001-09-0-021 03 - Smoke Detectors
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-09-0-023 03 - Smoke Detectors
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B B
£0 £0
10 10
0 0
0 0 0 0
0 0
2019 2019
Smoke detector in good order. Fire alarm panel in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
Location: 001-09-0-024 03 - Smoke Detectors
Location: 001-09-0-025 03 - Smoke Detectors
Location: 001-09-0-025A 03 - Smoke Detectors
Location: 001-09-0-026 03 - Smoke Detectors 05 - Fire Main/Zone Panel
Location: 001-09-0-026A 03 - Smoke Detectors
Location: 001-09-0-027 03 - Smoke Detectors
Location: 001-09-0-028 03 - Smoke Detectors
Location: 001-09-0-029 03 - Smoke Detectors
Location: 001-09-0-030 03 - Smoke Detectors
Location: 001-09-0-031 03 - Smoke Detectors
Location: 001-09-1-001 Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Smoke Detectors
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
2No. smoke detectors in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
Location: 001-09-1-002 03 - Smoke Detectors
Location: 001-09-1-003 03 - Smoke Detectors
Location: 001-09-1-004 03 - Smoke Detectors
Location: 001-09-1-005 03 - Smoke Detectors
Location: 001-09-1-006 03 - Smoke Detectors
Location: 001-09-1-007 03 - Smoke Detectors
Location: 001-09-1-008 03 - Smoke Detectors
Location: 001-09-1-009 03 - Smoke Detectors
Location: 001-09-1-012 03 - Smoke Detectors
Location: 001-09-1-013 03 - Smoke Detectors
Location: 001-09-1-014 03 - Smoke Detectors
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-09-1-015 03 - Smoke Detectors
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
Location: 001-09-1-015A 03 - Smoke Detectors
Location: 001-09-1-018 03 - Smoke Detectors
Location: 001-09-1-020 03 - Smoke Detectors
Location: 001-09-1-021 03 - Smoke Detectors
Location: 001-09-1-026 03 - Smoke Detectors
Location: 001-09-2-000 03 - Smoke Detectors
Location: 001-09-2-001 03 - Smoke Detectors
Location: 001-09-2-002 03 - Smoke Detectors
Location: 001-09-2-003 03 - Smoke Detectors
Location: 001-09-2-004 03 - Smoke Detectors
Location: 001-09-2-005 03 - Smoke Detectors Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-09-2-006 03 - Smoke Detectors
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
Location: 001-09-2-007 03 - Smoke Detectors
Location: 001-09-2-008 03 - Smoke Detectors
Location: 001-09-2-009 03 - Smoke Detectors
Location: 001-09-2-010 03 - Smoke Detectors
Location: 001-09-2-011 03 - Smoke Detectors
Location: 001-09-2-012 03 - Smoke Detectors
Location: 001-09-2-013 03 - Smoke Detectors
Location: 001-09-2-014 03 - Smoke Detectors
Location: 001-09-2-015 03 - Smoke Detectors
Location: 001-09-2-016 03 - Smoke Detectors
Location: 001-09-2-017 03 - Smoke Detectors Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-09-2-018 03 - Smoke Detectors
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B
£0
10
0
0 0
0
2019
Smoke detector in good order.
B B
£0 £0
12 12
0 0
0 0 0 0
0 0
2021 2021
Sounders in good order. Call points in good order.
Location: 001-09-2-019 03 - Smoke Detectors
Location: 001-09-2-020 03 - Smoke Detectors
Location: 001-09-2-021 03 - Smoke Detectors
Location: 001-09-2-022 03 - Smoke Detectors
Location: 001-09-2-023 03 - Smoke Detectors
Location: 001-09-2-024 03 - Smoke Detectors
Location: 001-09-2-025 03 - Smoke Detectors
Location: 001-09-2-026 03 - Smoke Detectors
Location: 001-09-2-027 03 - Smoke Detectors
Location: Whole Block 01 - Sounders 02 - Call Points Block Total Sample College Physical Condition Survey
£330,840.00 January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Site : Sample College - 001 Block : Sports Hall - 10 Facet: 1 - Building A - Building - Physical Structure
Location: Whole Block 01 - General Structure
B
£0
60
0
0 0
0
2069
Steel frame: Generally sound.
02 - Foundations 03 - Ground Stability
B B
£0 £0
80 80
0 0
0 0 0 0
0 0
2089 2089
Generally sound. Generally sound.
B(C)
£500
1
3
0 0
0
2010
Softwood timber: Redecorate and make good - located to elevation 2 - 1No. single & 1No. double.
B(C)
£600
1
3
0 0
0
2010
Softwood timber: Redecorate and make good located to elevation 3 - 2No. double.
C
£150
0
1
0 0
0
2009
Blockwork: Need to replace missing block - located to elevation 4.
B - Building - External Fabric
Location: Elevation 02 06 - Doors
Location: Elevation 03 06 - Doors
Location: Elevation 04 01b - Masonry - Spalling
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 02b - Cladding - Cracking
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
C
£800
0
1
0 0
0
2009
Evidence of vandalism, with making good required - located to elevation 4.
01a - Masonry - Cracking 01c - Masonry - Pointing
B B
£0 £0
40 40
0 0
0 0 0 0
0 0
2049 2049
Blockwork. Blockwork.
01d - Masonry - Finish 02a - Cladding - Attachment 02c - Cladding - Joints
B B B
£0 £0 £0
40 10 10
0 0 0
0 0 0 0 0 0
0 0 0
2049 2019 2019
Blockwork. Curtain walling: Metal. Curtain walling: Metal.
02d - Cladding - Finish 04 - Windows 06 - Doors 06 - Doors
B B B B
£0 £0 £0 £0
10 6 6 10
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2019 2015 2015 2019
Curtain walling: Metal. Aluminium - Double. Aluminium. Steel.
£1,040
2
4
0 0
0
2011
£0
6
0
0 0
0
2015
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition.
Location: Whole Block
C - Building - Internal Fabric
Location: 001-10-0-001 01 - Decorations
02 - Ceiling
Sample College Physical Condition Survey
B(C)
B
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 03 - Floor
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B(C)
£1,400
5
3
0 0
0
2014
Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition.
B(C)
£650
4
4
0 0
0
2013
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-10-0-002 01 - Decorations
02 - Ceiling
B
£0
10
0
0 0
0
2019
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
12
0
0 0
0
2021
08 - Fixed Units
B
£0
12
0
0 0
0
2021
B
£0
10
0
0 0
0
2019
£105
2
3
0 0
0
2011
Location: 001-10-0-003 02 - Ceiling 03 - Floor
B(C)
05 - Condition of Internal Walls
B
£0
25
0
0 0
0
2034
08 - Fixed Units
B
£0
6
0
0 0
0
2015
B
£0
10
0
0 0
0
2019
£105
5
3
0 0
0
2014
Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Fairfaced blockwork: In good condition. Fixed units: Sluice in good condition.
Location: 001-10-0-004 02 - Ceiling 03 - Floor
Sample College Physical Condition Survey
B(C)
Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
05 - Condition of Internal Walls
B
£0
25
0
0 0
0
2034
08 - Fixed Units
B
£0
10
0
0 0
0
2019
£650
4
4
0 0
0
2013
Notes
Remedial Action
Fairfaced blockwork: In good condition. Sanitary fittings: In good condition.
Location: 001-10-0-005 01 - Decorations
B(C)
02 - Ceiling
B
£0
10
0
0 0
0
2019
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
12
0
0 0
0
2021
08 - Fixed Units
B
£0
12
0
0 0
0
2021
B(C)
£78
4
4
0 0
0
2013
B
£0
10
0
0 0
0
2019
£105
4
3
0 0
0
2013
B
£0
10
0
0 0
0
2019
02 - Ceiling
B
£0
15
0
0 0
0
2024
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
25
0
0 0
0
2034
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Ceramic wall tiling: In good condition. Sanitary fittings: In good condition.
Location: 001-10-0-006 01 - Decorations
02 - Ceiling 03 - Floor
08 - Fixed Units
B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: Requires replacement within the maintenance schedule due to age and condition. Sanitary fittings: In good condition.
Location: 001-10-0-007
Sample College Physical Condition Survey
Exposed decking: In good condition. Vinyl sheet flooring: In good condition. Fairfaced blockwork: In good condition. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 05 - Condition of Internal Walls
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
B
£0
40
0
0 0
0
2049
Timber cladding: In good condition.
02 - Ceiling
B
£0
10
0
0 0
0
2019
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
25
0
0 0
0
2034
Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Fairfaced blockwork: In good condition.
02 - Ceiling
B
£0
10
0
0 0
0
2019
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
25
0
0 0
0
2034
02 - Ceiling
B
£0
10
0
0 0
0
2019
03 - Floor
B
£0
6
0
0 0
0
2015
05 - Condition of Internal Walls
B
£0
25
0
0 0
0
2034
01 - Decorations
C
£780
0
4
0 0
0
2009
02 - Ceiling
C
£150
0
3
0 0
0
2009
£1,050
1
3
0 0
0
2010
Location: 001-10-0-008
Location: 001-10-0-009 Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Fairfaced blockwork: In good condition.
Location: 001-10-0-010 Suspended ceiling: In good condition. Anti-slip vinyl sheet flooring: In good condition. Fairfaced blockwork: In good condition.
Location: 001-10-0-011
03 - Floor
Sample College Physical Condition Survey
B(C)
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: Replace water damaged tiles. Carpet: Requires replacement with contract quality carpet within the maintenance schedule. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
Location: 001-10-0-012 01 - Decorations
02 - Ceiling 03 - Floor
B(C)
£520
3
4
0 0
0
2012
£0
10
0
0 0
0
2019
B(C)
£700
5
3
0 0
0
2014
B(C)
£260
4
4
0 0
0
2013
£0
10
0
0 0
0
2019
B(C)
£350
3
3
0 0
0
2012
B B B B(C)
£0 £0 £0 £1,500
6 60 60 2
0 0 0 2
0 0 0 0
0 0 0 0
0 0 0 0
2015 2069 2069 2011
£0
6
0
0 0
0
2015
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
Location: 001-10-0-013 01 - Decorations
02 - Ceiling 03 - Floor
B
Redecoration required as part of a regular maintenance schedule. Suspended ceiling: In good condition. Carpet tiles: Require replacement with contract quality carpet within the maintenance schedule.
D - Building - Roof
Location: Roof 01 01a - Attached - Covering 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering 01h - Attached - Down Rainwater pipes
B
Metal. Metal. Metal. Box gutters: Repair joints to metal gutters. PVCU.
Location: Roof 02
Sample College Physical Condition Survey
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond. 01a - Attached - Covering
C
01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering
B B B(C)
01h - Attached - Down Rainwater pipes
Cost to B Rem Life Priority C L
R
Year
£1,500
0
3
0 0
0
2009
£0 £0 £600
60 60 2
0 0 2
0 0 0 0 0 0
0 0 0
2069 2069 2011
£0
6
0
0 0
0
2015
£0 £0 £0 £150
6 60 60 2
0 0 0 2
0 0 0 0
0 0 0 0
0 0 0 0
2015 2069 2069 2011
£0
6
0
0 0
0
2015
£0 £0 £0 £150
6 60 60 2
0 0 0 2
0 0 0 0
0 0 0 0
0 0 0 0
2015 2069 2069 2011
B
£0
6
0
0 0
0
2015
C
£1,500
0
2
0 0
0
2009
B
Notes
Remedial Action
Metal - there is evidence of deterioration to the plastic coating, with the cost allowing for the stripping and re-covering with plasticized paint. Metal. Metal. Box gutters: Repair joints to metal gutters. PVCU.
Location: Roof 03 01a - Attached - Covering 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering 01h - Attached - Down Rainwater pipes
B B B B(C) B
Metal. Metal. Metal. Box gutters: Repair joints to metal gutters. PVCU.
Location: Roof 04 01a - Attached - Covering 01e - Attached - Rafters 01f - Attached - Purlins 01g - Attached - Guttering 01h - Attached - Down Rainwater pipes
B B B B(C)
Metal. Metal. Metal. Box gutters: Repair joints to metal gutters. PVCU.
Facet: 2 - Engineering I - Engineering - Heating Systems
Location: Whole Block 01 - Heat Emitters
Sample College Physical Condition Survey
3No. steel panel radiators with no low surface temperature covers require replacement. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
01 - Heat Emitters
C
£2,000
0
2
0 0
0
2009
4No. heat emitters with no low surface temperature covers require replacement. 4No. steel panel radiators in the Staff Area in good order.
01 - Heat Emitters
B
£0
10
0
0 0
0
2019
B C
£0 £2,000
20 0
0 2
0 0 0 0
0 0
2029 2009
Ductwork in good order. 10No. grilles in sports hall are damaged and require replacement.
03 - Blending Valves
C
£500
0
2
0 0
0
2009
03 - Blending Valves 08 - Tanks & Bylaws
B B
£0 £0
10 10
0 0
0 0 0 0
0 0
2019 2019
Disused shower in staff locker room to be removed. Blending valves in good order. Plastic water storage tank in good order.
K - Engineering - Vent & Air Con
Location: Whole Block 01 - Ductwork 03 - Grilles & Diffusers
M - Engineering - Hot/Cold Water
Location: Whole Block
O - Engineering - Main Plant
Location: Whole Block 01 - Heating Boilers
B(C)
£5,000
5
3
0 0
0
2014
02 - Pumps
B(C)
£1,500
5
3
0 0
0
2014
Sample College Physical Condition Survey
Potterton Derwent heating boiler requires upgrading within the maintenance schedule. Grundfos heating pump requires upgrading within the maintenance schedule.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
02 - Pumps
B(C)
£750
5
3
0 0
0
2014
03 - Calorifiers
B(C)
£1,000
5
3
0 0
0
2014
B(C)
£5,000
5
3
0 0
0
2014
Notes
Remedial Action
Grundfos domestic hot water service return pump requires upgrading within the maintenance schedule. Lochinvar DGF calorifier requires upgrading within the maintenance schedule.
P - Engineering - Main Plant
Location: Whole Block 03 - Controls
04 - Extract Fans
B
£0
10
0
0 0
0
2019
04 - Extract Fans
B
£0
12
0
0 0
0
2021
£0 £2,000
10 5
0 3
0 0 0 0
0 0
2019 2014
05 - AHUs 07 - Flue Gas Termination
B B(C)
Control panel in good order but will require upgrading within the maintenance schedule. Vent Axia Solo extract fan in good order. Duct mounted box fan in good order. Sports hall AHU in good order. Flue dilution system requires upgrading within the maintenance schedule.
R - Engineering - Electrical
Location: Whole Block 03 - Distribution Boards
B
£0
20
0
0 0
0
2029
04 - Lighting Installation
C
£800
0
2
0 0
0
2009
04 - Lighting Installation
C
£1,200
0
2
0 0
0
2009
04 - Lighting Installation
B
£0
10
0
0 0
0
2019
05 - Emergency Lighting
B
£0
12
0
0 0
0
2021
Sample College Physical Condition Survey
MEM Memshield distribution board in good order. 4No. fluorescent lights over visual display equipment in the Staff Office are not suitable and require upgrading. 6No. fluorescent lights over visual display equipment in the Computer Room are not suitable and require upgrading. Surface fluorescent lights in good order. Emergency lights in good order. January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571
EstateManager
Property Appraisal - Detail Report Cond.
Cost to B Rem Life Priority C L
R
Year
Notes
Remedial Action
V - Engineering - Fire Alarms
Location: Whole Block 01 - Sounders
B
£0
10
0
0 0
0
2019
02 - Call Points
B
£0
10
0
0 0
0
2019
03 - Smoke Detectors 05 - Fire Main/Zone Panel
B B
£0 £0
10 10
0 0
0 0 0 0
0 0
2019 2019
£60,000
0
1
0 0
0
2009
Block Total
Fire alarm sounders in good order. Fire alarm call points in good order. Smoke detectors in good order. Fire alarm main panel in good order.
£37,143.00
Site : Sample College - 001 Block : Garage - 11 Facet: 1 - Building A - Building - Physical Structure
Location: Whole Block 01 - General Structure
Sample College Physical Condition Survey
C
Block Total
£60,000.00
Site Total
£2,474,790.00
Overall Total
£2,474,790.00
Concrete framed & clad garage with a suspected asbestos pitched roof: Building is beyond its life expectancy with complete replacement required. Cost allows for removal of the existing structure and a temporary building of a similar size to be installed.
January 2010 0000 Issued by Oakleaf Surveying Ltd - 0845 293 7571