Sat control catalog 9.11.2012

Page 1

Product Catalog Our systems and solutions for photovoltaic power plants

Turnkey systems and solutions for photovoltaic power plants


General Terms and Conditions

Dear Customers, Photovoltaic electricity, once confined to space exploration, has since the beginning of the 21st century, gained access to the realm of power generation. The impressive growth of the PV market, mainly driven during those years by the European interest for this particular technology, has since then led to a major decrease in system prices, bringing PV technology among the emerging technologies for power generation on a large scale. At Sat Control we are proud to be one of the first companies worldwide to successfully implement innovative, cost-effective, reliable, robust and active solar tracking systems in the world. Sat Control accelerates technological innovations by industry led research and development tracking systems offering outstanding long-term performance. Sat Control provides solutions that demonstrate cost effectiveness, added value, and go beyond the business. Setting the highest quality standards is Sat Control’s main objective. Sat Control products are a result of intensive research and development efforts, manufactured in a state of the art automated production environment and comply with the principal international standards: International Protection Rating (IEC 60529 IP33), Electromagnetic Compatibility (EMC Directive 89/336/EEC) and Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC). Components and materials used in production originate from well established suppliers, are pre-certified, tested and meet the highest quality standards. Due to the strict quality control at each step of the production process, Sat Control is able to offer its customers up to 10-year product warranty. Headquartered in Slovenia, at Sat Control we find our place predominantly in diverse international markets. Tracker installations of every size have been deployed internationally, including utility-scale projects in more than 45 countries over the world including Germany, France, Italy, Slovakia, Czech Republic, Australia, India, Canada and the United States. Sat Control’s strategic goal is to become globally innovative and competitive Solar Energy enterprise, providing the most appropriate solar tracking technology for achieving the highest performance and most cost-effective production of solar electricity. Bogdan Bolka CEO of Sat Control



Table of Contents

1. SOLAR LINEAR TRACKERS 1.a. DUAL AXIS SOLAR TRACKERS 1.a.1. 1.a.2. 1.a.3. 1.a.4. 1.a.5. 1.a.6.

SM44M3V15P ..................................................................... SM54M1V6P ....................................................................... SM44M1V4P ....................................................................... SM44M1V3P ....................................................................... SM44M1V2P ....................................................................... Iron-Reinforcement Cage .....................................................

page 1-2 page 3-6 page 7-10 page 11-14 page 15-18 page 19-20

1.b. SINGLE AXIS SOLAR TRACKERS 1.b.1. 1.b.2. 1.b.3. 1.b.4.

SM40M1V4P ....................................................................... SM40M1V3P ....................................................................... SM40M1V2P ....................................................................... SM3SPMOG+ .....................................................................

page 21-24 page 25-28 page 29-32 page 33-36

2. SOLAR PANELS 2.a.1. 2.a.2. 2.a.3. 2.a.4.

PV PV PV PV

panel panel panel panel

polycrystalline JC250M-24/Bb .................................. polycrystalline JC300M-24/Ab ................................. monocrystalline JC250S-24/Bb ................................ polycrystalline JC200S-24/Db ..................................

page 37-38 page 39-40 page 41-42 page 43-44

2.a.5. PV panel HJM195M-24 ........................................................ page 45-46 2.a.6. PV panel HJM250M-32 ......................................................... page 47-48 2.a.7. PV panel HJM180D-36 ......................................................... page 49-50

3. SOAR HELIOSTATS 3.a. SM44M1HEL3M ...................................................................... page 51-52 3.b. SM44M1HEL6M ..................................................................... page 53-54 3.c. SM44M3HEL25M .................................................................... page 55-56

4. SOLAR LINEAR MOTORS ACTUATORS 4.a. Motor SM4S520M1 ................................................................. 4.b. Motor SM4S900M3C3 - with Clamp C3 ...................................... 4.c. Motor SM4S900M3C4 - with Clamp C4 ..................................... 4.d. Motor SM4S900M3NC - without Clamp .....................................

page page page page

57-58 59-60 61-62 63-64


5. SOLAR POSITIONERS 5.a. SOLAR POSITIONER 2-AXIS MODULE NANO .............................. 5.b. SOLAR POSITIONER 2-AXIS MODULE MICRO .............................. 5.c. SIGMA SOLAR SERVER ............................................................ 5.d.1. SMPS Power supply TDK - Lambda DPP 50-24 ......................... 5.d.2. SMPS Power supply TDK - Lambda DPP 100-24 ....................... 5.d.3. SMPS Power supply TDK - Lambda DPP 480-24-3 .................... 5.e. Junction Box (j-box) Set & 5.f. Connection Board Sestiv 39B ........ 5.g. USB 2.0 to RS485 Mini Adapter with Terminal Block .................... 5.h. Cable USB 2.0 - USB-A -› Micro-B ............................................ 5.i. Wind sensor WS XS Vestmatic .................................................. 5.j. Plastic mounting bracket for wind sensor ...................................

page 65-66 page 67-68 page 69-70 page 71-71 page 71-71 page 72-72 page 73-74 page 75-75 page 76-76 page 77-77 page 78-78

6. GROUND SCREWS 6.a. GROUND SCREW ................................................................... page 79-81 6.b. SET GROUND SCREWS ........................................................... page 82-84

7. MONITORING SYSTEM 7.a. HELIOS ANALYTICS ............................................................... page 85-86

8. SAT CONTROL WEBSHOP 8.a. SAT CONTROL WEBSHOP ....................................................... page 87-88


1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS 1.a.1. SM44M3V15P

Product code: SM44M3V15P

Dual-Axis Solar Tracker SM44M3V15P Dual-Axis Solar Tracker SM44M3V15P with accuracy better than 0,5 deg and backstructure for 15 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 25 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h. In a Year basis with Dual axis motor you can get 7% more income of energy compared to Single axis motor.

1


1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS Technical Capabilities Mechanical Capabilities Number of turning axis

Dual-Axis

Hour Angle Limit

100˚, software and hardware limit

Elevation angle

15-90˚

Type of hour-angle engine

Linear Motor SM4S900M3 with stroke of 900 mm

Type of elevation shaft and stroke

Linear motor SM4S900M3 with stroke of 900mm

Hour-angle shaft diameter and length

Square tube 200x200 mm, L=2280 mm (steel)

Turning speed of hour angle shaft

/

Turning speed of elevation shaft

/

Max. dynamic torque of the hour-angle shaft

/

Max. dynamic torque of elevation shaft

/

Destructive torque of the hour-angle shaft

/

Destructive torque of elevation shaft

/

Backstructure size

5 x 5 m (H size 4 x 2,45 m)

Type of backstructure clamp

Toothed scissors gripers - 60 pcs

Tube diameter for mounting

Square tube 200x200 mm, H=3500 mm (steel)

Max. dimensions of a solar panel

15 pieces of 0.99 m x 1.67 m in total 25 m2

Max. weight of a solar panel

15 pcs per 30 kg

Estimated service life

5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data Tracking accuracy

<0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol

TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System

Servo driver positioner with TdAPS arc logic function calc.

Type of positioner

Din Rail positioner MICRO and externor cables

Type of timer

GMT clock with EOT and calendar

Type of application program for supervision and setting

Solar tracking system monitor via Helios Analytics

Setting and changing data via PC

Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC

Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC

Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval

1 minute (0.25°)

Communication Data Type of communication interface

USB interface

Networking solution for control from centre

CAN BUS, RS485

Firmware - Software Upgrading possibility via PC

Yes, firmware via PC with help of web wizard

Electrical Data Motor Power Supply

24 VDC ±15% 4A(5A current capacity)

Backup battery

CR 2512 coin

Turning time interval

1 minute (0.25°)

Max. Current of elevation shaft

/

Standby consumption (when is not moving)

60mA @ 24 VDC

Power supply connection

1 piece of 2 Wire Cable with an Internal Cu Conductor of 1.5mm2 (not included with kit)

Box

190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data Operating temperature

-25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity

0% to 100%, relative humidity

Max. safe wind speed

<130km/h (in vertical position) up to 180km/h (in horizontal position)

Corrosion, weather and chemical resistance Hot-dip galvanizing (HDG, EN ISO 1461)

75 - 100 μm (equivalent of 50 years)

Packaging Dimensions of a packed product

1 box of 5000 (L) x 800 (W) x 800 (H) mm (Wooden Box is not icluded with kit)

Product weight

750kg

Quality Certificates International Protection Rating (IEC 60529)

IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC)

Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC)

Yes

Optional Properties Anti-Shadowing Function

Yes, included

Heliostat usage

Yes, for additional payment

2


1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS 1.a.2. SM54M1V6P

Product code: SM54M1V6P

Dual Axis Solar Tracker SM54M1V6P

3

Dual-Axis Solar Tracker SM54M1V6P with accuracy better than 0,5 deg and backstructure for 6 pieces of solar panels dimensions 0,808 m x 1,580 m and weight of 25 kg max each. So together for 7,65 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at small and large solar power plants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 130km/h. In a Year basis with 2 axis motor you can get 7% more income of energy compared to single axis motor. Solar tracker anti-shadowing software function included.


1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

Technical Capabilities Mechanical Capabilities Number of turning axis

Dual-Axis, Azimuth-Elevation System

Azimuth Angle Limit

270˚

Elevation angle

90˚

Type of Azimuth-angle engine

Slew drive SM5M1

Type of elevation shaft and stroke

Linear motor SM4S520M1

Azimuth-angle shaft diameter and length

/

Turning speed of Azimuth angle shaft

0,9˚/s

Turning speed of elevation shaft

0,052 - 0,062 °/s at no load

Max. dynamic torque of the Azimuth-angle shaft

Azimuth 150 Nm

Max. dynamic torque of elevation shaft

330 Nm - 400 Nm depend from EA

Destructive torque of the Azimuth-angle shaft

1500 Nm

Destructive torque of elevation shaft

1250 Nm - 1500 Nm, depend from HA

Backstructure size

2,424 m x 3,160 m

Type of backstructure clamp

Toothed gripers - 24 pcs

Tube diameter for mounting

Ø133 x 3 mm

Max. dimensions of a solar panel

Array of 6 pieces of 0,808 m x 1,580 m in total 7,65 m2

Max. weight of a solar panel

6 pcs per 25 kg

Estimated service life

5.000 rotations of 200° (100°E + 100°W), or 10 years

Communication Data Type of communication interface

RS485

Networking solution for control from centre

RS485

Firmware - Software Upgrading possibility via PC

Yes, firmware via PC with help of web wizard

Electrical Data Motor Power Supply

24 VDC ± 10% (2A current capacity)

Backup battery

/

Turning time interval

5 sec - 15 minute, but controlled via Sigma Solar Server Web based

Max. consumption during the operation of the Azimuth-angle shaft

500 mA @ 150 Nm

Max. Current of elevation shaft

500 mA @ 400Nm

Standby consumption (when is not moving)

25 mA ± 25% @ 24V

Power supply connection

1 cable of 2 wires with an Internal Cu Conductor of 1,0 mm2 for power and 1 twisted pair 0,25mm2 (2 wires) (not included with kit)

Environmental Data Operating temperature

-25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity

0% to 100%, relative humidity

Max. safe wind speed

<130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance Neutral Salt Spray (3000 h, EN ISO 9227 NSS)

/

Hot-dip galvanizing (HDG, EN ISO 1461)

75 - 100 μm (equivalent of 50 years)

Packaging Dimensions of a packed product

/

Product weight

155kg

Quality Certificates International Protection Rating (IEC 60529)

IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC)

Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC)

Yes

Optional Properties Anti-Shadowing Function

Yes, but controlled via Sigma Solar Server Web based

Heliostat usage

Yes, but controlled via Sigma Solar Server Web based

4


1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS 1.a.2. SM54M1V6P

5


1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS 1.a.2. SM54M1V6P

Real energy measurement of two equal solar panels (fixed and motorized)

Two equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): Date: Time: Geo. Latitude: Weather conditions:

1.17 kWp (producer spec. at AM 1.5) May 2011 4:00 to 20:00 (sun time) 46째 N sunny, but not totally clear

Results: Average energy of fixed: 4890.6Wh Average energy of motorized: 7920.9Wh

Note: Sum of motor energy consumption through all day is 35.5Wh or 0.22% of all collected energy.

6


1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS 1.a.3. SM44M1V4P

Product code: SM44M1V4P

Dual Axis Solar Tracker SM44M1V4P Dual Axis Solar Tracker SM44M1V4P with accuracy better than 0,5 deg and backstructure for 4 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 7,7 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h. In a Year basis with 2 axis motor you can get 7% more income of energy compared to single axis motor. Solar tracker anti-shadowing software function included.

7


1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS Technical Capabilities Mechanical Capabilities Number of turning axis

Dual-Axis

Hour Angle Limit

100˚, software and hardware limit

Elevation angle

15-90˚, adjustable start

Type of hour-angle engine

Linear Motor SM4S520M1 with stroke of 520 mm

Type of elevation shaft and stroke

Linear motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length

Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft

0,039 - 0,063 °/s at no load, see graph

Turning speed of elevation shaft

0,052 - 0,062 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft

200 Nm - 330 Nm depend from HA, see graph

Max. dynamic torque of elevation shaft

330 Nm - 400 Nm depend from EA, see graph

Destructive torque of the hour-angle shaft

750 Nm - 1250 Nm, depend from HA, see graph

Destructive torque of elevation shaft

1250 Nm - 1500 Nm, depend from HA, see graph

Backstructure size

2 pcs of 1000 (H) mm & 2 pcs of 4000 (V) mm

Type of backstructure clamp

Toothed scissors gripers - 16 pcs

Tube diameter for mounting

Ø76,1 x 3,6 mm with reduced tube to Ø68 mm (not included with kit)

Max. dimensions of a solar panel

4 pieces of 0,99 m x 1,95 m in total 7,7 m2

Max. weight of a solar panel

4 pcs per 30 kg

Estimated service life

5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data Tracking accuracy

<0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol

TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System

Servo driver positioner with TdAPS arc logic function calc.

Type of positioner

Din Rail positioner MICRO and externor cables

Type of timer

GMT clock with EOT and calendar

Type of application program for supervision and setting

Solar tracking system monitor via web site

Setting and changing data via PC

Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC

Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC

Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval

Tipicaly 6 - 7 s

Communication Data Type of communication interface

USB interface

Networking solution for control from centre

CAN BUS, RS485

Firmware - Software Upgrading possibility via PC

Yes, firmware via PC with help of web wizard

Electrical Data Motor Power Supply

24 VDC ± 10% (2A current capacity)

Backup battery

CR 2512 coin

Max. consumption during the operation of the hour-angle shaft

500 mA @ 330 Nm, see graph

Max. Current of elevation shaft

500 mA @ 400 Nm, see graph

Standby consumption (when is not moving)

20 mA ± 25% @ 24V

Power supply connection

1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Box

190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data Operating temperature

-25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity

0% to 100%, relative humidity

Max. safe wind speed

<130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance Hot-dip galvanizing (HDG, EN ISO 1461)

75 - 100 μm (equivalent of 50 years)

Packaging Dimensions of a packed product

1 box of 1600 (L) x 245 (W) x 202 (H) mm & 1 box of 2050 (L) x 180 (W) x 70 (H) mm

Product weight

55 kg

Quality Certificates International Protection Rating (IEC 60529)

IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC)

Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC)

Yes

Optional Properties Anti-Shadowing Function

Yes, included

Heliostat usage

Yes, for additional payment

8


1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS 1.a.3. SM44M1V4P

Legend:

Legend:

Legend:

9


1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS 1.a.3. SM44M1V4P 2 Real energy measurement of two equal solar panels (fixed and motorized) Legend:

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46째 N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic signalisations,Legend: street light, cot-

Real energy measurement of two equal solar panels (fixed and motorized)

Two equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): Date: Time: Geo. Latitude: Weather conditions:

1.2 kWp (producer spec. at AM 1.5) July 2010 4:00 to 20:00 (sun time) 46째 N sunny, but not totally clear

Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh

Note: Sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy.

10


1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS 1.a.4. SM44M1V3P

Product code: SM44M1V3P

Dual-Axis Solar Tracker SM44M1V3P Dual-Axis Solar Tracker SM44M1V3P with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h. In a Year basis with Dual Axis motor you can get 7% more income of energy compared to Single Axis motor.

11


1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS Technical Capabilities Mechanical Capabilities Number of turning axis

Dual-Axis

Hour Angle Limit

100˚, software and hardware limit

Elevation angle

15-90˚, adjustable start

Type of hour-angle engine

Linear Motor SM4S520M1 with stroke of 520 mm

Type of elevation shaft and stroke

Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length

Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft

0,039 - 0,063 °/s at no load, see graph

Turning speed of elevation shaft

0,052 - 0,062 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft

200 Nm - 330 Nm depend from HA, see graph

Max. dynamic torque of elevation shaft

330 Nm - 400 Nm depend from EA, see graph

Destructive torque of the hour-angle shaft

750 Nm - 1250 Nm, depend from HA, see graph

Destructive torque of elevation shaft

1250 Nm - 1500 Nm, depend from HA, see graph

Backstructure size

2 pcs of 1000 (H) mm & 2 pcs of 3000 (V) mm

Type of backstructure clamp

Toothed scissors gripers - 12 pcs

Tube diameter for mounting

Ø60 - 68 mm (not included with kit)

Max. dimensions of a solar panel

3 pieces of 0,99 m x 1,95 m in total 5,8 m2

Max. weight of a solar panel

3 pcs per 30 kg

Estimated service life

5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data Tracking accuracy

<0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol

TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System

Servo driver positioner with TdAPS arc logic function calc.

Type of positioner

Din Rail positioner MICRO and externor cables

Type of timer

GMT clock with EOT and calendar

Type of application program for supervision and setting

Solar tracking system monitor via web site

Setting and changing data via PC

Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC

Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC

Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval

Tipicaly 6 - 7 s

Communication Data Type of communication interface

USB interface

Networking solution for control from centre

CAN BUS, RS485

Firmware - Software Upgrading possibility via PC

Yes, firmware via PC with help of web wizard

Electrical Data Motor Power Supply

24 VDC ± 10% (2A current capacity)

Backup battery

CR 2512 coin

Max. consumption during the operation of the hour-angle shaft

500 mA @ 330 Nm, see graph

Max. Current of elevation shaft

500 mA @ 400 Nm, see graph

Standby consumption (when is not moving)

20 mA ± 25% @ 24V

Power supply connection

1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Box

190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data Operating temperature

-25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity

0% to 100%, relative humidity

Max. safe wind speed

<130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance Hot-dip galvanizing (HDG, EN ISO 1461)

75 - 100 μm (equivalent of 50 years)

Packaging Dimensions of a packed product

1 box of 1600 (L) x 245 (W) x 202 (H) mm

Product weight

45 kg

Quality Certificates International Protection Rating (IEC 60529)

IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC)

Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC)

Yes

12


1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS 1.a.4. SM44M1V3P

Legend:

Legend:

Legend:

13


1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS 1.a.4. SM44M1V3P 2 Real energy measurement of two equal solar panels (fixed and motorized) Legend:

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46째 N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic signalisations,Legend: street light, cot-

Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): Date: Time: Geo. Latitude: Weather conditions:

0.9 kWp (producer spec. at AM 1.5) July 2010 4:00 to 20:00 (sun time) 46째 N sunny, but not totally clear

Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh

Note: Sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy.

14


1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS 1.a.5. SM44M1V2P

Product code: SM44M1V2P

Dual-Axis Solar Tracker SM44M1V2P Dual-Axis Solar Tracker SM44M1V2P with accuracy better than 0,5 deg and backstructure for 2 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 4,0 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h. In a Year basis with Dual Axis motor you can get 7% more income of energy compared to Single Axis motor.

15


1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS Technical Capabilities Mechanical Capabilities Number of turning axis

Dual-Axis

Hour Angle Limit

100˚, software and hardware limit

Elevation angle

15-90˚, adjustable start

Type of hour-angle engine

Linear Motor SM4S520M1 with stroke of 520 mm

Type of elevation shaft and stroke

Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length

Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft

0,039 - 0,063 °/s at no load, see graph

Turning speed of elevation shaft

0,052 - 0,062 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft

200 Nm - 330 Nm depend from HA, see graph

Max. dynamic torque of elevation shaft

330 Nm - 400 Nm depend from EA, see graph

Destructive torque of the hour-angle shaft

750 Nm - 1250 Nm, depend from HA, see graph

Destructive torque of elevation shaft

1250 Nm - 1500 Nm, depend from HA, see graph

Backstructure size

2 pcs of 1000 (H) mm & 2 pcs of 2000 (V) mm

Type of backstructure clamp

Toothed scissors gripers - 8 pcs

Tube diameter for mounting

Ø60 - 68 mm (not included with kit)

Max. dimensions of a solar panel

2 pieces of 0,99 m x 1,95 m in total 3,9 m2

Max. weight of a solar panel

2 pcs per 30 kg

Estimated service life

5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data Tracking accuracy

<0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol

TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System

Servo driver positioner with TdAPS arc logic function calc.

Type of positioner

Din Rail positioner MICRO and externor cables

Type of timer

GMT clock with EOT and calendar

Type of application program for supervision and setting

Solar tracking system monitor via web site

Setting and changing data via PC

Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC

Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC

Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval

Tipicaly 6 - 7 s

Communication Data Type of communication interface

USB interface

Networking solution for control from centre

CAN BUS,

RS485

Firmware - Software Upgrading possibility via PC

Yes, firmware via PC with help of web wizard

Electrical Data Motor Power Supply

24 VDC ± 10% (2A current capacity)

Backup battery

CR 2512 coin

Max. consumption during the operation of the hour-angle shaft

500 mA @ 330 Nm, see graph

Max. Current of elevation shaft

500 mA @ 400 Nm, see graph

Standby consumption (when is not moving)

20 mA ± 25% @ 24V

Power supply connection

1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Box

190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data Operating temperature

-25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity

0% to 100%, relative humidity

Max. safe wind speed

<130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance Hot-dip galvanizing (HDG, EN ISO 1461)

75 - 100 μm (equivalent of 50 years)

Packaging Dimensions of a packed product

1 box of 1600 (L) x 245 (W) x 202 (H) mm

Product weight

35 kg

Quality Certificates International Protection Rating (IEC 60529)

IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC)

Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC)

Yes

Optional Properties Anti-Shadowing Function

Yes, included

Heliostat usage

Yes, for additional payment

16


1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS 1.a.5. SM44M1V2P

Legend:

Legend:

Legend:

17


1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS 1.a.5. SM44M1V2P 2 Real energy measurement of two equal solar panels (fixed and motorized) Legend:

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46째 N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic signalisations,Legend: street light, cot-

Real energy measurement of two equal solar panels (fixed and motorized)

Two equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): Date: Time: Geo. Latitude: Weather conditions:

0.6 kWp (producer spec. at AM 1.5) July 2010 4:00 to 20:00 (sun time) 46째 N sunny, but not totally clear

Results: Average energy of fixed: 2508,0Wh Average energy of motorized: 4062,0Wh

Note: Sum of motor energy consumption through all day is 17.52Wh or 0.43% of all collected energy.

18


1. IRON - REINFORCEMENT CAGE 1.a.6. Iron-reinforcement cage JEKABBSM44M3V15P

Product code: JEKABBSM44M3V15P

Iron-reinforcement cage for Overground Concrete Foundation for Solar Tracker SM40M3V15P The foundation of the solar power system can take various forms. Consequently, optimum consideration can be given to the local conditions. The rectangular overground foundation is generally used if a stony or rocky substrate precludes an underground variant of the foundation structure.

19


1. IRON - REINFORCEMENT CAGE Technical Capabilities

1.a.6. Iron-reinforcement cage JEKABBSM44M3V15P

20


1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS 1.b.1. SM40M1V4P

Product code: SM40M1V4P

Single-Axis Solar Tracker SM40M1V4P Single-Axis Solar Tracker SM40M1V4P with accuracy better than 0,5 deg and backstructure for 4 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 7,7 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h. In a year basis with Dual Axis motor you can get 7% more income of energy compared to Single Ais motor.

21


1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS Technical Capabilities Mechanical Capabilities Number of turning axis

Single-Axis

Hour Angle Limit

100˚, software and hardware limit

Elevation angle

15-90˚, adjustable start

Type of hour-angle engine

Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length

Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft

0,039 - 0,063 °/s at no load, see graph

Max. dynamic torque of the

200 - 330 Nm depend from HA, see graph

le shaft

Destructive torque of the hour-angle shaft

750 Nm - 1250 Nm, depend from HA, see graph

Backstructure size

2 pcs of 1000 (H) mm & 2 pcs of 4000 (V) mm

Type of backstructure clamp

Toothed scissors gripers - 16 pcs

Tube diameter for mounting

Ø76,1 x 3,6 mm with reduced tube to Ø68 mm (not included with kit)

Max. dimensions of a solar panel

4 pieces of 0,99 m x 1,95 m in total 7,7 m2

Max. weight of a solar panel

4 pcs per 30 kg

Estimated service life

5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data Tracking accuracy

<0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol

TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System

Servo driver positioner with TdAPS arc logic function calc.

Type of positioner

Din Rail positioner MICRO and externor cables

Type of timer

GMT clock with EOT and calendar

Type of application program for supervision and setting

Solar tracking system monitor via web site

Setting and changing data via PC

Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC

Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC

Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval

Tipicaly 6 - 7 s

Communication Data Type of communication interface

USB interface

Networking solution for control from centre

CAN BUS, RS485

Firmware - Software Upgrading possibility via PC

Yes, firmware via PC with help of web wizard

Electrical Data Motor Power Supply

24 VDC ± 10% (2A current capacity)

Backup battery

CR 2512 coin

Max. consumption during the operation of the hour-angle shaft

500 mA @ 330 Nm, see graph

Max. Current of elevation shaft

500 mA @ 400 Nm, see graph

Standby consumption (when is not moving)

20 mA ± 25% @ 24V

Power supply connection

1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Box

190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data Operating temperature

-25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity

0% to 100%, relative humidity

Max. safe wind speed

<130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance Hot-dip galvanizing (HDG, EN ISO 1461)

75 - 100 μm (equivalent of 50 years)

Packaging Dimensions of a packed product

1 box of 1600 (L) x 245 (W) x 202 (H) mm & 1 box of 2050 (L) x 180 (W) x 70 (H) mm

Product weight

52 kg

Quality Certificates International Protection Rating (IEC 60529)

IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC)

Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC)

Yes

Optional Properties Anti-Shadowing Function

Yes, included

Heliostat usage

No

22


1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS 1.b.1. SM40M1V4P

Legend:

Legend:

Legend:

23


1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS 1.b.1. SM40M1V4P 2 Real energy measurement of two equal solar panels (fixed and motorized) Legend:

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46째 N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic signalisations,Legend: street light, cot-

Real energy measurement of two equal solar panels (fixed and motorized)

Two equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): Date: Time: Geo. Latitude: Weather conditions:

1.2 kWp (producer spec. at AM 1.5) July 2010 4:00 to 20:00 (sun time) 46째 N sunny, but not totally clear

Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh

Note: Sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy.

24


1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS 1.b.2. SM40M1V3P

Product code: SM40M1V3P

Single-Axis Solar Tracker SM40M1V3P Single-Axis Solar Tracker SM40M1V3P with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h.

25


1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS Technical Capabilities Mechanical Capabilities Number of turning axis

Single-Axis

Hour Angle Limit

100˚, software and hardware limit

Elevation angle

15-90˚, adjustable start

Type of hour-angle engine

Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length

Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft

0,039 - 0,063 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft

200 - 330 Nm depend from HA, see graph

Destructive torque of the hour-angle shaft

750 Nm - 1250 Nm, depend from HA, see graph

Backstructure size

2 pcs of 1000 (H) mm & 2 pcs of 3000 (V) mm

Type of backstructure clamp

Toothed scissors gripers - 12 pcs

Tube diameter for mounting

Ø60 - 68 mm (not included with kit)

Max. dimensions of a solar panel

3 pieces of 0,99 m x 1,95 m in total 5,8 m2

Max. weight of a solar panel

3 pcs per 30 kg

Estimated service life

5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data Tracking accuracy

<0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol

TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System

Servo driver positioner with TdAPS arc logic function calc.

Type of positioner

Din Rail positioner MICRO and externor cables

Type of timer

GMT clock with EOT and calendar

Type of application program for supervision and setting

Solar tracking system monitor via web site

Setting and changing data via PC

Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC

Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC

Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval

Tipicaly 6 - 7 s

Communication Data Type of communication interface

USB interface

Networking solution for control from centre

CAN BUS, RS485

Firmware - Software Upgrading possibility via PC

Yes, firmware via PC with help of web wizard

Electrical Data Motor Power Supply

24 VDC ± 10% (2,5A current capacity)

Backup battery

CR 2512 coin

Max. consumption during the operation of the hour-angle shaft

500 mA @ 330 Nm, see graph

Max. Current of elevation shaft

500 mA @ 400 Nm, see graph

Standby consumption (when is not moving)

20 mA ± 25% @ 24V

Power supply connection

1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Box

190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data Operating temperature

-25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity

0% to 100%, relative humidity

Max. safe wind speed

<130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance Hot-dip galvanizing (HDG, EN ISO 1461)

75 - 100 μm (equivalent of 50 years)

Packaging Dimensions of a packed product

1 box of 1600 (L) x 245 (W) x 202 (H) mm

Product weight

41 kg

Quality Certificates International Protection Rating (IEC 60529)

IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC)

Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC)

Yes

Optional Properties Anti-Shadowing Function

Yes, included

Heliostat usage

No

26


1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS 1.b.2. SM40M1V3P

Legend:

Legend:

Legend:

27


1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS 1.b.2. SM40M1V3P 2 Real energy measurement of two equal solar panels (fixed and motorized) Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46째 N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Legend: Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes:ofon-grid atsolar roofpanels on houses, trafic signalisations, street light, cotReal energy measurement two equal (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): Date: Time: Geo. Latitude: Weather conditions:

0.9 kWp (producer spec. at AM 1.5) July 2010 4:00 to 20:00 (sun time) 46째 N sunny, but not totally clear

Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh

Note: Sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy.

28


1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS 1.b.3. SM40M1V2P

Product code: SM40M1V2P

Single-Axis Solar Tracker SM40M1V2P Single-Axis Solar Tracker SM40M1V2P with accuracy better than 0,5 deg and backstructure for 2 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 4,0 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h.

29


1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS Technical Capabilities Mechanical Capabilities Number of turning axis

Single-Axis

Hour Angle Limit

100˚, software and hardware limit

Elevation angle

15-90˚, adjustable start

Type of hour-angle engine

Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length

Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft

0,039 - 0,063 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft

200 - 330 Nm depend from HA, see graph

Destructive torque of the hour-angle shaft

750 Nm - 1250 Nm, depend from HA, see graph

Backstructure size

2 pcs of 1000 (H) mm & 2 pcs of 2000 (V) mm

Type of backstructure clamp

Toothed scissors gripers - 8 pcs

Tube diameter for mounting

Ø60 - 68 mm (not included with kit)

Max. dimensions of a solar panel

2 pieces of 0,99 m x 1,95 m in total 3,9 m2

Max. weight of a solar panel

2 pcs per 30 kg

Estimated service life

5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data Tracking accuracy

<0,5˚ (optionally <0,1˚ ***)

Operating Protocol

TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System

Servo driver positioner with TdAPS arc logic function calc.

Type of positioner

Din Rail positioner MICRO and externor cables

Type of timer

GMT clock with EOT and calendar

Type of application program for supervision and setting

Solar tracking system monitor via web site

Setting and changing data via PC

Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC

Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC

Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval

Tipicaly 6 - 7 s

Communication Data Type of communication interface

USB interface

Networking solution for control from centre

CAN BUS, RS485

Firmware - Software Upgrading possibility via PC

Yes, firmware via PC with help of web wizard

Electrical Data Motor Power Supply

24 VDC ± 10% (2A current capacity)

Backup battery

Backup for timer, position and data

Max. consumption during the operation of the hour-angle shaft

500 mA @ 330 Nm, see graph

Max. Current of elevation shaft

500 mA @ 400 Nm, see graph

Standby consumption (when is not moving)

20 mA ± 25% @ 24V

Power supply connection

1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Box

190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data Operating temperature

-25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity

0% to 100%, relative humidity

Max. safe wind speed

<130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance Hot-dip galvanizing (HDG, EN ISO 1461)

75 - 100 μm (equivalent of 50 years)

Packaging Dimensions of a packed product

1 box of 1600 (L) x 245 (W) x 202 (H) mm

Product weight

35 kg

Quality Certificates International Protection Rating (IEC 60529)

IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC)

Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC)

Yes

Optional Properties Anti-Shadowing Function

Yes, included

Heliostat usage

No

30


1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS 1.b.3. SM40M1V2P

Legend:

Legend:

Legend:

31


1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS 1.b.3. SM40M1V2P 2 Real energy measurement of two equal solar panels (fixed and motorized) Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46째 N Weather conditions: sunny, but not totally clear Results: Legend: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes:ofon-grid atsolar roofpanels on houses, trafic signalisations, street light, cotReal energy measurement two equal (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): Date: Time: Geo. Latitude: Weather conditions:

0.6 kWp (producer spec. at AM 1.5) July 2010 4:00 to 20:00 (sun time) 46째 N sunny, but not totally clear

Results: Average energy of fixed: 2508,0Wh Average energy of motorized: 4062,0Wh

Note: Sum of motor energy consumption through all day is 17.52Wh or 0.43% of all collected energy.

32


1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS 1.b.4. SM3SPMOG+

Product code: SM3SPMOG+

Solar Tracker SM3SPMOG+ Single-Axis Solar Tracker SM3SPMOG+ made to be supplied with power from 12 to 69 VDC from external power supply. Without charger controller. Suitable for panels on grid Up to dimensions 2m x 1m usage at homes on-grid at roof on houses, for trafic signalisation, for street light use, for power suplly at cottages, for small and large powerplants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h is required and price is imporant too. All metal gear parts inside ensure high destruction forces.

33


1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS Technical Capabilities Mechanical Capabilities Number of turning axis

Single-Axis

Hour Angle Limit

96˚ typical / 100˚ max., software and hardware limit

Elevation angle

75° manual fixation

Type of hour-angle engine

Servo motor with position encoder on cogwheel

Hour-angle shaft diameter and length

Ø40 mm, L=1150 mm (steel)

Turning speed of hour angle shaft

0,5°/s ± 25% @ 24V at no load

Max. dynamic torque of the hour-angle shaft

65 Nm

Destructive torque of the hour-angle shaft

>200 Nm

Backstructure size

2 pcs of 1000 (H) mm

Type of backstructure clamp

Toothed scissors gripers - 4 pcs

Tube diameter for mounting

Ø50,0 - 60,0 mm

Max. dimensions of a solar panel

1 piece of 2,0 m x 1,0 m in total 2,0 m2

Max. weight of a solar panel

1 pc per 25 kg

Estimated service life

5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data Tracking accuracy

<0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol

TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System

Servo driver positioner with TdAPS arc logic function calc.

Type of Positioner

Solar Positioner SP27C

Type of timer

GMT clock with EOT and calendar

Type of application program for supervision and setting

Solar tracking system monitor via web site

Setting and changing data via PC

Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC

Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC

Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval

1 minute (0,25°)

Communication Data Type of communication interface

USB interface since beginning of the January 2010, before RS232

Networking solution for control from centre

CAN BUS, RS485

Firmware - Software Upgrading possibility via PC

Yes, firmware via PC with help of web wizard

Electrical Data Motor Power Supply

Recommended 24 VDC (working from 12 to 69 VDC), (2,5 A current capacity @ 12V)

Backup battery

CR 2512 coin

Max. consumption during the operation of the hour-angle shaft

500 mA @ 65 Nm

Standby consumption (when is not moving)

35 mA ± 25% @ 24V

Power supply connection

1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Environmental Data Operating temperature

-25°C to +70°C

Operation at humidity

0% to 100%, relative humidity

Max. safe wind speed

<130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance Packaging Dimensions of a packed product

1 box of 1175 (L) x 135 (W) x 200 (H) mm

Product weight

9 kg

Quality Certificates International Protection Rating (IEC 60529)

IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC)

Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC)

Yes

Optional Properties Anti-Shadowing Function

Yes, included

Heliostat usage

No

34


1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS 1.b.4. SM3SPMOG+

G.L. and +15˚ or -15˚ according to the season

SET TO THE CALCULATED ANGLE FOR EXAMPLE: 45˚

35


1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS 1.b.4. SM3SPMOG+ 2 Real energy measurement of two equal solar panels (fixed and motorized) Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Legend: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46째 N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes:ofon-grid atsolar roofpanels on houses, trafic signalisations, street light, cotReal energy measurement two equal (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): Date: Time: Geo. Latitude: Weather conditions:

200W (producer spec. at AM 1.5) July 2010 4:00 to 20:00 (sun time) 46째 N sunny, but not totally clear

Results: Average energy of fixed: 836,8Wh Average energy of motorized: 1354,0Wh

Note: Sum of motor energy consumption through all day is 20Wh or 1.45% of all collected energy.

36


2. SOLAR PANELS 2.a.1. PV panel polycrystalline JC250M-24/Bb, 40mm frame

Product code: PVPJC250M24BB

High Module Conversion Efficiencies

Easy Installation and Handling

Mechanical Load Capability of up to 5400 Pa

Conforms with IEC 61215:2005, IEC 61730: 2004, UL 1703 PV Standards

ISO9001, OHSAS18001, ISO14001 Certified

Performance Figures in %

100%

97

.5 %

97

.5 %

95%

Linear Performance Warranty

Adde d Va lue

90% 85% 80%

8

0 0.

%

Traditional Warranty

0% 0 1

5

10

15

20

25

YEAR

PV panel polycrystalline JC250M-24/Bb Sat control offers high-power, high-quality, and highly efficient PV modules ideal for gridconnected and standalone systems. The modules characterized by outstanding longterm performance are designed to withstand rigorous operating conditions using proven and highest quality certified materials. IEC 61215 Ed.2 certificate is granted.

37


2. SOLAR PANELS

• Dimensions 992mm

• Curves 40mm

947mm 10 2

1 000W/m

4-7.5X7.5 DRAIN HOLE

JUNCTION BOX

8

800W/m

860mm 1360mm

1640mm

1000mm

Current (A)

LABLE

6

2

2

600W/m

4

400W/m

2

200W/m

2

2

2- 4 GROUNDING HOLE

0 0

5

10

15

20

25

30

35

40

Voltage (V)

8- 9X5 INSTALLING HOLE

Varied Irradiation Efficiencies

16-8X3.5 DRAIN HOLE

Irradiance

200W/m 2

400W/m 2

600W/m 2

Efficiency

15.5%

15.9%

15.9%

800W/m 2 15.8%

JC250M-24/Bb

JC255M-24/Bb

250 W

255 W

0 ~ +5W

0 ~ +5W

15.4%

15.7%

8.31 A

8.39 A

30.1 V

30.4 V

8.83 A

8.86 A

37.4 V

37.5 V

JC250M-24/Bb

JC255M-24/Bb

Maximum Power (Pmax)

185 W

189 W

Maximum Power Current (lmp)

6.57 A

6.63 A

Maximum Power Voltage (Vmp)

28.2 V

28.5 V

Short Circuit Current (lsc)

7.12 A

7.20 A

Open Circuit Voltage (Voc)

35.0 V

35.1 V

Electrical Characteristics NOCT

1000W/m

2

15.7%

Values at Normal Operating Cell Temperature, Irradiance of 800 W/m2 , spectrum AM 1.5, ambient temperature 20oC, wind speed 1 m/s

Characteristics

Mechanical Characteristics Cell Type

156 x156 mm Polycrystalline, 60 (6x10) pcs in series

Temperature Coefficient of Voc

Glass

High Transmission, Low lron, Tempered Glass

Temperature Coefficient of Isc

Frame

Anodized Aluminum Alloy

Temperature Coefficient of Pmax

Junction Box

IP65/IP67 rated, with bypass diodes

Nominal Operating Cell Temperature (NOCT)

Dimension

*1640 x 992 x 40 mm

Output Cable

4 mm2 (EU)/12 AWG (US), 1000 mm

Weight

19 Kg

Installation Hole Location

See Drawing Above

Maximum Ratings

Packing Information Container

20’ GP

40’ GP

40’ HQ

Operating Temperature

Pallets per Container

12

28

28

Maximum System Voltage

Pieces per Container

300

700

770

Maximum Series Fuse Rating

38


2. SOLAR PANELS 2.a.2. PV panel polycrystalline JC300M-24/Ab, 40mm frame

Product code: PVPJC300M24AB

High Module Conversion Efficiencies

Easy Installation and Handling

Mechanical Load Capability of up to 5400 Pa

Conforms with IEC 61215:2005, IEC 61730: 2004, UL 1703 PV Standards

ISO9001, OHSAS18001, ISO14001 Certified

Performance Figures in %

100%

97

.5 % 7 .5 % 9

95%

Linear Performance Warranty

Adde d Va lue

90% 85% 80%

8

0 0.

%

Traditional Warranty

0% 0 1

5

10

15

20

25

YEAR

PV panel polycrystalline JC300M-24/Ab Sat control offers high-power, high-quality, and highly efficient PV modules ideal for gridconnected and standalone systems. The modules characterized by outstanding longterm performance are designed to withstand rigorous operating conditions using proven and highest quality certified materials. IEC 61215 Ed.2 certificate is granted.

39


2. SOLAR PANELS

• Dimensions

• Curves

992mm

947mm 10 4-7.5X7.5 DRAIN HOLE

JUNCTION BOX

8

LABLE

Current (A)

4

1176mm 1676mm

1000mm

1956mm

6

2

2- 4 GROUNDING HOLE

0 0

10

20

30

40

50

Voltage (V)

8- 9X5 INSTALLING HOLE 16-8X3.5 DRAIN HOLE

Varied Irradiation Efficiencies Irradiance

200W/m 2

400W/m 2

600W/m 2

Efficiency

15.1%

15.5%

15.6%

800W/m 2 15.6%

1000W/m 2 15.5%

JC295M-24/Ab

JC300M-24/Ab

295 W

300 W

0 ~ +5W

0 ~ +5W

15.2%

15.5%

8.13 A

8.20 A

36.3 V

36.6 V

8.62 A

8.69 A

44.7 V

44.8 V

JC295M-24/Ab

JC300M-24/Ab

219 W

222 W

6.57 A

6.67 A

33.3 V

33.4 V

6.96 A

7.02 A

41.8 V

41.9 V

Characteristics

Mechanical Characteristics Cell Type

156 x156 mm Polycrystalline, 72 (6x12) pcs in series

Temperature Coefficient of Voc

Glass

High Transmission, Low lron, Tempered Glass

Temperature Coefficient of Isc

Frame

Anodized Aluminum Alloy

Temperature Coefficient of Pmax

Junction Box

IP65/IP67 rated, with bypass diodes

Nominal Operating Cell Temperature (NOCT)

Dimension

*1956 x 992 x 50 mm

Output Cable

4 mm2 (EU)/12 AWG (US), 1000 mm

Weight

29 Kg

Installation Hole Location

See Drawing Above

Maximum Ratings

Packing Information Container

20’ GP

40’ GP

40’ HQ

Operating Temperature

Pallets per Container

10

24

24

Maximum System Voltage

Pieces per Container

200

480

528

Maximum Series Fuse Rating

40


2. SOLAR PANELS 2.a.3. PV panel monocrystalline JC250S-24/Bb, 40mm frame

Product code: PVPJC250S24BB

High Module Conversion Efficiencies

Easy Installation and Handling

Mechanical Load Capability of up to 5400 Pa

Conforms with IEC 61215:2005, IEC 61730: 2004, UL 1703 PV Standards

ISO9001, OHSAS18001, ISO14001 Certified

Performance Figures in %

100%

96

.5 % 6 .5 % 9

95%

Linear Performance Warranty

Adde d Va lue

90% 85%

80

80%

% .0

Traditional Warranty

0% 0 1

5

10

15

20

25

YEAR

PV panel monocrystalline JC250S-24/Bb Sat control offers high-power, high-quality, and highly efficient PV modules ideal for gridconnected and standalone systems. The modules characterized by outstanding longterm performance are designed to withstand rigorous operating conditions using proven and highest quality certified materials. IEC 61215 Ed.2 certificate is granted.

41


2. SOLAR PANELS

• Dimensions 992mm

• Curves 40mm

947mm 10

1000W/m˛ 4-7.5X7.5 DRAIN HOLE

JUNCTION BOX

8

800W/m˛

860mm 1360mm

1640mm

1000mm

Current (A)

LABLE

2- 4 GROUNDING HOLE

6

600W/m˛

4

400W/m˛

2

200W/m˛

0 0

5

10

15

20

25

30

35

40

Voltage (V)

8- 9X5 INSTALLING HOLE 16-8X3.5 DRAIN HOLE

Varied Irradiation Efficiencies Irradiance

200W/m 2

400W/m 2

600W/m 2

Efficiency

15.9%

16.2%

16.2%

800W/m 2 16.1%

JC250S-24/Bb

JC255S-24/Bb

JC260S-24/Bb

250 W

255 W

260 W

0 ~ +5W

0 ~ +5W

0 ~ +5W

15.4%

15.7%

16.0%

8.32 A

8.44 A

8.55 A

30.1 V

30.2 V

30.4 V

8.87 A

8.99 A

9.10 A

37.5 V

37.6 V

37.7 V

JC250S-24/Bb

JC255S-24/Bb

JC260S-24/Bb

184 W

188 W

191 W

6.57 A

6.62 A

6.66 A

28.0 V

28.4 V

28.7 V

7.15 A

7.21 A

7.28 A

35.1 V

35.2 V

35.3 V

1000W/m 2 16.0%

Characteristics

Mechanical Characteristics Cell Type

156 x156 mm Monocrystalline, 60 (6x10) pcs in series

Temperature Coefficient of Voc

Glass

High Transmission, Low lron, Tempered Glass

Temperature Coefficient of Isc

Frame

Anodized Aluminum Alloy

Temperature Coefficient of Pmax

Junction Box

IP65/IP67 rated, with bypass diodes

Nominal Operating Cell Temperature (NOCT)

Dimension

*1640 x 992 x 40 mm

Output Cable

4 mm2 (EU)/12 AWG (US), 1000 mm

Weight

19 Kg

Installation Hole Location

See Drawing Above

Maximum Ratings

Packing Information Container

20’ GP

40’ GP

40’ HQ

Operating Temperature

Pallets per Container

12

28

28

Maximum System Voltage

Pieces per Container

300

700

770

Maximum Series Fuse Rating

42


2. SOLAR PANELS 2.a.4. PV panel monocrystalline JC200S-24/Db, 35mm frame

Product code: PVPJC200S24DB

High Module Conversion Efficiencies

Easy Installation and Handling

Mechanical Load Capability of up to 5400 Pa

Conforms with IEC 61215:2005, IEC 61730: 2004, UL 1703 PV Standards

ISO9001, OHSAS18001, ISO14001 Certified

Performance Figures in %

100%

96

.5 % 6 .5 % 9

95%

Linear Performance Warranty

Adde d Va lue

90% 85%

80

80%

.

0%

Traditional Warranty

0% 0 1

5

10

15

20

25

YEAR

PV panel monocrystalline JC200S-24/Db Sat control offers high-power, high-quality, and highly efficient PV modules ideal for gridconnected and standalone systems. The modules characterized by outstanding longterm performance are designed to withstand rigorous operating conditions using proven and highest quality certified materials. IEC 61215 Ed.2 certificate is granted.

43


2. SOLAR PANELS

• Dimensions 808mm

• Curves 35mm 6

1000W/m˛

Current (A)

5

800W/m˛

4

600W/m˛ 3

400W/m˛

1580mm

2

200W/m˛ 1

0 0

10

20

30

40

50

Voltage (V )

Varied Irradiation Efficiencies Irradiance

200W/m 2

400W/m 2

600W/m 2

Efficiency

15.4%

15.8%

15.8%

800W/m 2 15.8%

JC190S-24/Db

JC195S-24/Db

JC200S-24/Db

190 W

195 W

200 W

0 ~ +5W

0 ~ +5W

0 ~ +5W

14.9%

15.3%

15.7%

5.19 A

5.32 A

5.41 A

36.6 V

36.7 V

37.1 V

5.49 A

5.61 A

5.70 A

44.9 V

45.0 V

45.3 V

JC190S-24/Db

JC195S-24/Db

JC200S-24/Db

140 W

144 W

147 W

4.13 A

4.22 A

4.27 A

34.0 V

34.2 V

34.5 V

4.42 A

4.52 A

4.60 A

42.1 V

42.3 V

42.4 V

1000W/m 2 15.7%

Characteristics

Mechanical Characteristics Cell Type

125 x125 mm Monocrystalline, 72 (6x12) pcs in series

Temperature Coefficient of Voc

Glass

High Transmission, Low lron, Tempered Glass

Temperature Coefficient of Isc

Frame

Anodized Aluminum Alloy

Temperature Coefficient of Pmax

Junction Box

IP65/IP67 rated, with bypass diodes

Nominal Operating Cell Temperature (NOCT)

Dimension

*1580 x 808 x 35 mm

Output Cable

4 mm2 (EU)/12 AWG (US), 1000 mm

Weight

16 Kg

Installation Hole Location

See Drawing Above

Maximum Ratings

Packing Information Container

20’ GP

40’ GP

40’ HQ

Operating Temperature

Pallets per Container

12

28

28

Maximum System Voltage

Pieces per Container

372

868

952

Maximum Series Fuse Rating

44


2. SOLAR PANELS 2.a.5. Photovoltaic solar panel HJM195M-24

Product code: PVSPHJM195M24

808 (31.8) 35 (1.38)

80 (3.15)

762 (30.0) 35 (1.38)

4-6*6 Waterspout

Junction box (IP65) Bar code

90 (3.54)

8-14*9 Mounting slots

800 (31.5)

1300 (51.2)

1580 (62.2)

130 (5.12)

Lable

2- 4 Ground hole Cable 900mm

Cable 900mm 16-3.5*8 Waterspout

9 (0.35)

70 (2.76)

70 (2.76)

PV panel monocrystalline HJM195M-24 The HJM195D-24, HJSOLAR Solar’s 195 watt photovoltaic module features 17-18% encapsulated cell efficiency and 15.2% module efficiency. With a 25 year warranty, the HJM195D-24 has superb durability to withstand rigorous operating conditions. Ideal for grid-connected and remote power systems, the HJM185D-36 modules offer the maximum usable power per square foot of solar array.

45


2. SOLAR PANELS

Electrical Characteristics HJM190M-24

Model type

190W

Peak power (Pmax) Cell type

HJM195M-24

HJM200M-24

195W

200W

Mono Crystalline Silicon, 125mm x 125mm

Maximum power voltage (Vmp)

36.71

37.59

37.87

Maximum power current (Imp)

5.16

5.20

5.29

44.06

44.46

44.86

5.57

5.62

5.71

Open circuit voltage (Voc) Short circuit current (Isc) Maximum system voltage

TUV DC 1000V/UL DC600V

Temp. Coeff. of Isc (TK Isc) Temp.

0.037 %/ °C

Coeff. of Voc (TK Voc) Temp.

- 0.34 %/ °C

Coeff. of Pmax (TK Pmax)

- 0.37 %/ °C

Normal operating cell temperature

45 ± 2 °C

Power tolerance

±3 %

Standard test conditions (STC)

AM1.5, 1000W/m2, Module Temperature 25 °C

Mechanical Characteristics Dimension (mm)

1580 x 808 x 35

Weight (kg)

16.5

Solar cells

72 cells (125 mm x 125 mm) configured geometrically for a 6 x 12 matrix connected in series

Output cable length (mm)

900

Construction

Front: High transmission 3.2 mm tempered glass. Rear: White backsheet; Encapsulant: EVA.

Features

Current-Voltage & Power-Voltage Curve

• High module conversion efficiency up to 15.7%.

6.0

240

5.0

200

4.0

160

3.0

120

2.0

80

1.0

40

• 90% power output over 12 years • 80% power output over 25 years • Bypass diode minimizes the power drop caused by shade. • Tempered glass, EVA resin, and weatherproof film, and anodized aluminum frame for extended outdoor use. • TUV UL Listings: UL 1703, IEC61215, IEC61730.

Packing Configuration Container

20’ GP

40’ GP

Pieces per pallet

26

26

Pallets per container

12

28

Pieces per container

312

728

Current (A)

• Free from defects in materials and workmanship for 5 years

Power (W)

• 25-year limited warranty on power output:

0

0.0 0

10

20

30

40

50

Voltage (V) 1000 W/m2

900 W/m2

800 W/m2

46


2. SOLAR PANELS 2.a.6. Photovoltaic solar panel HJM250M-32

Product code: PVSPHJM250M32

1062 (41.8) 80 (3.15)

1016 (40.0) 45 (1.77)

35 (1.38)

4-6*6 Waterspout

Junction box (IP65) Bar code

90 (3.54)

8-14*9 Mounting slots

800 (31.5)

1300 (51.2)

1580 (62.2)

130 (5.12)

Lable

2- 4 Ground hole Cable 900mm

Cable 900mm 16-3.5*8 Waterspout

9 (0.35)

70 (2.76)

70 (2.76)

PV panel monocrystalline HJM250M-32 The HJM250M-32, HJSOLAR Solar’s 250 watt photovoltaic module features 17-18% encapsulated cell efficiency and 15.2% module efficiency. With a 25 year warranty, the HJM250M-32 has superb durability to withstand rigorous operating conditions. Ideal for grid-connected and remote power systems, the HJM250M32 modules offer the maximum usable power per square foot of solar array.

47


2. SOLAR PANELS

Electrical Characteristics HJM250M-32

Model type

HJM255M-32

HJM260M-32

255W

260W

250W

Peak power (Pmax) Cell type

Mono Crystalline Silicon, 125mm x 125mm

Maximum power voltage (Vmp)

50.60

Maximum power current (Imp) Open circuit voltage (Voc) Short circuit current (Isc)

50.80

51.00

4.94

5.02

5.10

60.50

60.70

61.00

5.42

5.51

5.35

Maximum system voltage

TUV DC 1000V/UL DC600V

Temp. Coeff. of Isc (TK Isc) Temp.

0.037 %/ °C

Coeff. of Voc (TK Voc) Temp.

- 0.34 %/ °C

Coeff. of Pmax (TK Pmax)

- 0.37 %/ °C 45 ± 2 °C

Normal operating cell temperature Power tolerance

±3 % AM1.5, 1000W/m , Module Temperature 25°C

Standard test conditions (STC)

2

Mechanical Characteristics Dimension (mm)

1580 x 1062 x 45

Weight (kg)

22

Solar cells

96 cells (125 mm x 125 mm) configured geometrically for a 8 x 12 matrix connected in series

Output cable length (mm)

900

Construction

Front: High transmission 3.2 mm tempered glass. Rear: White backsheet; Encapsulant: EVA.

Features

Current-Voltage & Power-Voltage Curve

• High module conversion efficiency up to 15.5%.

6.0

300

80% power output over 25 years

5.0

250

4.0

200

3.0

150

2.0

100

1.0

50

Free from defects in materials and workmanship for 5 years • Bypass diode minimizes the power drop caused by shade. • Tempered glass, EVA resin, and weatherproof film, and anodized aluminum frame for extended outdoor use. • TUV UL Listings: UL 1703, IEC61215, IEC61730.

Current (A)

90% power output over 12 years

0.0

Packing Configuration Container

20’ GP

40’ GP

Pieces per pallet

20

20

Pallets per container

12

28

Pieces per container

240

560

0

10

20

30

40

50

60

70

Power (W)

• 25-year limited warranty on power output:

0

Voltage (V) 1000 W/m 2

800 W/m 2

500 W/m 2

48


2. SOLAR PANELS 2.a.7. Photovoltaic solar panel HJM-180D-36

Product code: PVSPHJM180D36

PV panel monocrystalline HJM-180D-36 The HJM185D-36, HJSOLAR Solar’s 185 watt photovoltaic module features 18% encapsulated cell efficiency and 15.5% module efficiency. With a 25 year warranty, the HJM185D-36 has superb durability to withstand rigorous operating conditions. Ideal for grid-connected and remote power systems, the HJM185D-36 modules offer the maximum usable power per square foot of solar array.

49


2. SOLAR PANELS ELECTRICAL DATA The electrical data applies to standard test conditions (STC): Irradiance at the module level of 1,000 W/m2 with spectrum AM 1.5 and a cell temperature of 25° C HJM175D-36

HJM180D-36

HJM185D-36

HJM190D-36

170W

175W

180W

185W

190W

Cell type

MonoCrystalline Silicon, 125mm x 125mm

Number of cells

72 cells in a series

Weight

16.5 kg

Dimensions Maximum power voltage (Vmp) Maximum power current (Imp) Open circuit voltage (Voc) Short circuit current (Isc) Maximum system voltage

1580×808×45mm 36.48

36.59

4.66 43.86 5.03

36.59

36.71

36.71

4.78

4.92

5.04

5.16

43.92

43.92

44.06

44.06

5.16

5.31

5.44

TUV DC 1000V/UL DC600V

Temp. Coeff. of Isc (TK Isc) Temp.

0.009%/ oC

Coeff. of Voc (TK Voc) Temp.

-0.34%/ oC

C oe ff. o f P m a x (T K P ma x)

-0.37 %/ oC

ELECTRICAL CHARACTERISTICS 6

240 1000W/m˛ 900W/m˛

5

200

Current(A)

800W/m˛ 4

150

3

120

2

60

1

40

0

0 0

10

20

30

40

50

Voltage(V)

Temperature dependence of Isc, Voc and Pmax 100

ISC

Normalize Isc, Voc and Pmax(%)

PHYSICAL CHARACTERISTICS

45±2 oC

80

Voc Pmax

60

40

20

0 -25

0

25

50

75

100

400

600

800

1000

100

Voc

Normalize Isc, Voc and Pmax(%)

Normal Temperature

5.57

Power(W)

Peak power(Pmax)

HJM170D-36

Power(W)

Model type

80

60

40

ISC 20

Pmax

0 0

200

Irradiance(W/m˛)

50


3. SOLAR HELIOSTATS 3.a. SM44M1HEL3M

Product code: SM44M1HEL3M

Single-Axis Solar Heliostat SM44M1HEL3M Dual-Axis Solar Heliostat SM44M1HEL3M for mirror application up to 3,1m2 enable cost-effective large-scale sun tracking all over the course of the day with unprecedented accuracy.

51


3. SOLAR HELIOSTATS Technical Capabilities Mechanical Capabilities Number of turning axis

Dual-Axis

Hour Angle Limit

100˚, software and hardware limit

Elevation angle

15-90˚, adjustable start

Type of hour-angle engine

Linear Motor SM4S520M1 with stroke of 520 mm

Type of elevation shaft and stroke

Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length

Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft

0,039 - 0,063 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft

200 - 330 Nm depend from HA, see graph

Max. dynamic torque of elevation shaft

330 Nm - 400 Nm depend from EA, see graph

Destructive torque of the hour-angle shaft

750 Nm - 1250 Nm, depend from HA, see graph

Destructive torque of elevation shaft

1250 Nm - 1500 Nm, depend from HA, see graph

Backstructure size

1.250 (H) mm x 1.500 (V) mm

Type of backstructure clamp

Toothed scissors gripers 4 pcs

Tube diameter for mounting

Ø60 - 68 mm (not included with kit)

Max. dimensions of a mirror panel

1 mirror panel with dimensions of 1.250 mm x 2.500 mm with net surface of 3,1 m2

Max. weight of a mirror panel

90 kg

Estimated service life

5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data Tracking accuracy

<0,1˚

Operating Protocol

TdAPS (Time derived Astronomical Positioning System)

Type of positioner

Din Rail positioner MICRO and externor cables

Type of timer

GMT clock with EOT and calendar

Type of application program for supervision and setting

Solar tracking system monitor via Helios Analytics

Setting and changing data via PC

Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC

Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC

Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Communication Data Type of communication interface

USB interface

Networking solution for control from centre

RS485

Firmware - Software Upgrading possibility via PC

Yes, firmware via PC with help of web wizard

Electrical Data Motor Power Supply

24 VDC ± 10% (2A current capacity)

Backup battery

CR 2512 coin

Turning time interval

Tipicaly 6 - 7 s

Max. consumption during the operation of the hour-angle shaft

500 mA @ 330 Nm, see graph

Max. Current of elevation shaft

500 mA @ 400 Nm, see graph

Standby consumption (when is not moving)

20 mA ± 25% @ 24V

Power supply connection

1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Environmental Data Operating temperature

-25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity

0% to 100%, relative humidity

Max. safe wind speed

<130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance Hot-dip galvanizing (HDG, EN ISO 1461)

75 - 100 μm (equivalent of 50 years)

Packaging Dimensions of a packed product

1 box of 1600 (L) x 245 (W) x 202 (H) mm

Product weight

45 kg

Quality Certificates International Protection Rating (IEC 60529)

IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC)

Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC)

Yes

Optional Properties Anti-Shadowing Function

No

Solar Mirror

Solar Mirror SolReflex® HM3C1M-3 for additional payment

52


3. SOLAR HELIOSTATS 3.b. SM44M1HEL6M

Product code: SM44M1HEL6M

Single-Axis Solar Heliostat SM44M1HEL3M Dual-Axis Solar Heliostat SM44M1HEL6M for mirror application up to 6,2m2 enable cost-effective large-scale sun tracking all over the course of the day with unprecedented accuracy.

53


3. SOLAR HELIOSTATS Technical Capabilities Mechanical Capabilities Number of turning axis

Dual-Axis

Hour Angle Limit

100˚, software and hardware limit

Elevation angle

15-90˚, adjustable start

Type of hour-angle engine

Linear Motor SM4S520M1 with stroke of 520 mm

Type of elevation shaft and stroke

Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length

Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft

0,039 - 0,063 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft

200 - 330 Nm depend from HA, see graph

Max. dynamic torque of elevation shaft

330 Nm - 400 Nm depend from EA, see graph

Destructive torque of the hour-angle shaft

750 Nm - 1250 Nm, depend from HA, see graph

Destructive torque of elevation shaft

1250 Nm - 1500 Nm, depend from HA, see graph

Backstructure size

2.500 (H) mm x 1.500 (V) mm

Type of backstructure clamp

Toothed scissors gripers 8 pcs

Tube diameter for mounting

Ø60 - 68 mm (not included with kit)

Max. dimensions of a mirror panel

2 mirror panels with dimensions of 1.250 mm x 2.500 mm with net surface of 6,2 m2

Max. weight of a mirror panel

90 kg

Estimated service life

5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data Tracking accuracy

<0,1˚

Operating Protocol

TdAPS (Time derived Astronomical Positioning System)

Type of positioner

Din Rail positioner MICRO and externor cables

Type of timer

GMT clock with EOT and calendar

Type of application program for supervision and setting

Solar tracking system monitor via Helios Analytics

Setting and changing data via PC

Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC

Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC

Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Communication Data Type of communication interface

USB interface

Networking solution for control from centre

RS485

Firmware - Software Upgrading possibility via PC

Yes, firmware via PC with help of web wizard

Electrical Data Motor Power Supply

24 VDC ± 10% (2A current capacity)

Backup battery

CR 2512 coin

Turning time interval

Tipicaly 6 - 7 s

Max. consumption during the operation of the hour-angle shaft

500 mA @ 330 Nm, see graph

Max. Current of elevation shaft

500 mA @ 400 Nm, see graph

Standby consumption (when is not moving)

20 mA ± 25% @ 24V

Power supply connection

1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Environmental Data Operating temperature

-25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity

0% to 100%, relative humidity

Max. safe wind speed

<130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance Hot-dip galvanizing (HDG, EN ISO 1461)

75 - 100 μm (equivalent of 50 years)

Packaging Dimensions of a packed product

1 box of 1600 (L) x 245 (W) x 202 (H) mm

Product weight

45 kg

Quality Certificates International Protection Rating (IEC 60529)

IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC)

Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC)

Yes

Optional Properties Anti-Shadowing Function

No

Solar Mirror

Solar Mirror SolReflex® HM3C1M-3 for additional payment

54


3. SOLAR HELIOSTATS 3.c. SM44M3HEL25M

Product code: SM44M3HEL25M

Single-Axis Solar Heliostat SM44M1HEL25M Dual-Axis Solar Heliostat SM44M1HEL25M for mirror application up to 25m2 enable cost-effective large-scale sun tracking all over the course of the day with unprecedented accuracy.

55


3. SOLAR HELIOSTATS Technical Capabilities Mechanical Capabilities Number of turning axis

Dual-Axis

Hour Angle Limit

100˚, software and hardware limit

Elevation angle

15-90˚, adjustable start

Type of hour-angle engine

Linear Motor SM4S900M3 with stroke of 900 mm

Type of elevation shaft and stroke

Linear Motor SM4S900M3 with stroke of 900 mm

Hour-angle shaft diameter and length

Square tube 110x110 mm, L=5000 mm (steel)

Turning speed of hour angle shaft

/

Max. dynamic torque of the hour-angle shaft

/

Max. dynamic torque of elevation shaft

/

Destructive torque of the hour-angle shaft

/

Destructive torque of elevation shaft

/

Backstructure size

/

Type of backstructure clamp

Toothed scissors gripers 48 pcs

Tube diameter for mounting

Square tube 200x200 mm, H=3500 mm (steel)

Max. dimensions of a mirror panel

8 mirror panels with dimensions of 1.250 mm x 2.500 mm with net surface of 25 m2

Max. weight of a mirror panel

/

Estimated service life

5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data Tracking accuracy

<0,1˚

Operating Protocol

TdAPS (Time derived Astronomical Positioning System)

Type of positioner

Din Rail positioner MICRO and externor cables

Type of timer

GMT clock with EOT and calendar

Type of application program for supervision and setting

Solar tracking system monitor via Helios Analytics

Setting and changing data via PC

Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC

Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC

Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Communication Data Type of communication interface

USB interface

Networking solution for control from centre

RS485

Firmware - Software Upgrading possibility via PC

Yes, firmware via PC with help of web wizard

Electrical Data Motor Power Supply

24VDC +/- 15% 4A (5A current capability)

Backup battery

CR 2512 coin

Turning time interval

1 minute (0.25°)

Max. consumption during the operation of the hour-angle shaft

/

Max. Current of elevation shaft

/

Standby consumption (when is not moving)

60mA @ 24 VDC

Power supply connection

1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Environmental Data Operating temperature

-25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity

0% to 100%, relative humidity

Max. safe wind speed

<130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance Hot-dip galvanizing (HDG, EN ISO 1461)

75 - 100 μm (equivalent of 50 years)

Packaging Dimensions of a packed product

/

Product weight

/

Quality Certificates International Protection Rating (IEC 60529)

IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC)

Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC)

Yes

Optional Properties Anti-Shadowing Function

No

Solar Mirror

Solar Mirror SolReflex® HM3C1M-3 for additional payment

56


4. SOLAR LINEAR MOTORS 4.a. Motor SM4S520M1

Product code: Motor SM4S520M1

Professional Solar Linear Actuator - Motor SM4S520M1 Professional Solar Linear Actuator - Motor SM4S520M1. Standard precision 0,5 degrees. Advanced precision 0,1 degrees for addtional payment. Suitable for PV panels, concentrators - CPV and Heliostats. Heliostats for addtional payment. Usage: small and large powerplants, on-grid at roof on houses or factories, cottages, solar tower powerplant, where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Solar tracker anti-shadowing software function included.

57


4. SOLAR LINEAR MOTORS 4.a. Motor SM4S520M1 Technical Capabilities Mechanical Capabies Construction material of linear motor

Stainless steel tubes and spindle and high carbon steel

Spindle type and material

ACME stainless spindle

Stroke lenght

520 mm

Max. static load

3400 N

Dynamic load capacity

1000 N

Rod end type

Spherical bearing with hole dia. Ø12 mm with pivot angle of 13º

Speed at no load

0,9 mm/s at no load, 0,4 mm/s at max. load

Resolution

380,8 pulses/mm (min step is 0,0026 mm)

Backlash

max 0,2 mm

Electrical Data Motor Power Supply

24VDC +/- 15% 0,2A (0,5A current capability)

Backup battery

/

Turning time interval

/

Power consumption in operation

Tipicaly 3-6 W, max 10 W

Standby consumption (when is not moving)

/

Power supply connection

1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included in kit)

Environmental Data Operating temperature

-25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity

0% to 100%, relative humidity

Corrosion, weather and chemical resistance Corrosion Protection

PLASOX® plasmanitriding with subsequent oxidation

Packaging Dimensions of a packed product

1box of 1000(L) x 80(W) x 60(H) mm

Product weight

3,46 kg + 1 kg box weight

Quality Certificates International Protection Rating (IEC 60529)

IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC)

Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC)

Yes

Optional Properties Heliostat usage

Yes, for additional payment

CPV usage (concentrated PV usage)

Yes, all types including round parabolic - for additional payment

Guarantee time

2 years as standard, 5 years for +20% - for additional payment, 10 years for +35% - for additional payment

58


4. SOLAR LINEAR MOTORS 4.b. Motor SM4S900M3C3 - with Clamp C3

Product code: Motor SM4S900M3C3

Professional Solar Linear Actuator - Motor SM4S900M3C3 Professional Solar Linear Actuator - Motor SM4S900M3C3. Standard precision 0,5 degrees. Advanced precision 0,1 degrees for addtional payment. Suitable for PV panels, concentrators - CPV, and heliostats. Usage: small and large powerplants, on-grid at roof on houses or factories, cottages, solar tower powerplant, where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Solar tracker anti-shadowing software function included.

59


4. SOLAR LINEAR MOTORS 4.b. Motor SM4S900M3C3 - with Clamp C3 Technical Capabilities Mechanical Capabies Construction material of linear motor

Stainless steel tubes and spindle and high carbon steel

Spindle type and material

ACME stainless spindle

Stroke lenght

900 mm

Max. static load

15000 N

Dynamic load capacity

8000 N

Rod end type

Spherical bearing with hole dia. Ø12 mm with pivot angle of 13º

Speed at no load

2,33 mm/s

Resolution

294 pulses/mm (min step is 0,0034 mm)

Backlash

max 0,15 mm

Electrical Data Motor Power Supply

24VDC +/- 15% 4A (5A current capability)

Backup battery

/

Turning time interval

/

Power consumption in operation

Tipicaly 20-50 W, max 100 W

Standby consumption (when is not moving)

/

Power supply connection

1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,5 mm2 (not included in kit)

Environmental Data Operating temperature

-25°C to +85°C (optionally with artic grease for teperatures from -40°C up to +85°C)

Operation at humidity

0% to 100%, relative humidity

Corrosion, weather and chemical resistance Corrosion Protection

PLASOX® plasmanitriding with subsequent oxidation

Packaging Dimensions of a packed product

1 box of 1600 (L) x 80 (W) x 80 (H) mm

Product weight

8,5 kg

Quality Certificates International Protection Rating (IEC 60529)

IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC)

Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC)

Yes

Optional Properties Heliostat usage

Yes

CPV usage (concentrated PV usage)

Yes, all types including round parabolic

Guarantee time

2 years as standard, 5 years for +20% *** 10 years for +35% ***

60


4. SOLAR LINEAR MOTORS 4.c. Motor SM4S900M3C4 - with Clamp C4

Product code: Motor SM4S900M3C4

Professional Solar Linear Actuator - Motor SM4S900M3C4 Professional Solar Linear Actuator - Motor SM4S900M3C4. Standard precision 0,5 degrees. Advanced precision 0,1 degrees for addtional payment. Suitable for PV panels, concentrators - CPV, and heliostats. Usage: small and large powerplants, on-grid at roof on houses or factories, cottages, solar tower powerplant, where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Solar tracker anti-shadowing software function included.

61


4. SOLAR LINEAR MOTORS 4.c. Motor SM4S900M3C4 - with Clamp C4 Technical Capabilities Mechanical Capabies Construction material of linear motor

Stainless steel tubes and spindle and high carbon steel

Spindle type and material

ACME stainless spindle

Stroke lenght

900 mm

Max. static load

15000 N

Dynamic load capacity

8000 N

Rod end type

Spherical bearing with hole dia. Ø12 mm with pivot angle of 13º

Speed at no load

2,33 mm/s

Resolution

294 pulses/mm (min step is 0,0034 mm)

Backlash

max 0,15 mm

Electrical Data Motor Power Supply

24VDC +/- 15% 4A (5A current capability)

Backup battery

/

Turning time interval

/

Power consumption in operation

Tipicaly 20-50 W, max 100 W

Standby consumption (when is not moving)

/

Power supply connection

1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,5 mm2 (not included in kit)

Environmental Data Operating temperature

-25°C to +85°C (optionally with artic grease for teperatures from -40°C up to +85°C)

Operation at humidity

0% to 100%, relative humidity

Corrosion, weather and chemical resistance Corrosion Protection

PLASOX® plasmanitriding with subsequent oxidation

Packaging Dimensions of a packed product

1 box of 1600 (L) x 80 (W) x 80 (H) mm

Product weight

8,5 kg

Quality Certificates International Protection Rating (IEC 60529)

IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC)

Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC)

Yes

Optional Properties Heliostat usage

Yes

CPV usage (concentrated PV usage)

Yes, all types including round parabolic

Guarantee time

2 years as standard, 5 years for +20% *** 10 years for +35% ***

62


4. SOLAR LINEAR MOTORS 4.d. Motor Motor SM4S900M3NC

Product code: Motor SM4S900M3NC

Professional Solar Linear Actuator - Motor SM4S900M3NC Professional Solar Linear Actuator - Motor SM4S900M3NC. Standard precision 0,5 degrees. Advanced precision 0,1 degrees for addtional payment. Suitable for PV panels, concentrators - CPV, and heliostats. Usage: small and large powerplants, on-grid at roof on houses or factories, cottages, solar tower powerplant, where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Solar tracker anti-shadowing software function included.

63


4. SOLAR LINEAR MOTORS 4.d. Motor Motor SM4S900M3NC Technical Capabilities Mechanical Capabies Construction material of linear motor

Stainless steel tubes and spindle and high carbon steel

Spindle type and material

ACME stainless spindle

Stroke lenght

900 mm

Max. static load

15000 N

Dynamic load capacity

8000 N

Rod end type

Spherical bearing with hole dia. Ø12 mm with pivot angle of 13º

Speed at no load

2,33 mm/s

Resolution

294 pulses/mm (min step is 0,0034 mm)

Backlash

max 0,15 mm

Electrical Data Motor Power Supply

24VDC +/- 15% 4A (5A current capability)

Backup battery

/

Turning time interval

/

Power consumption in operation

Tipicaly 20-50 W, max 100 W

Standby consumption (when is not moving)

/

Power supply connection

1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,5 mm2 (not included in kit)

Environmental Data Operating temperature

-25°C to +85°C (optionally with artic grease for teperatures from -40°C up to +85°C)

Operation at humidity

0% to 100%, relative humidity

Corrosion, weather and chemical resistance Corrosion Protection

PLASOX® plasmanitriding with subsequent oxidation

Packaging Dimensions of a packed product

1 box of 1600 (L) x 80 (W) x 80 (H) mm

Product weight

8,5 kg

Quality Certificates International Protection Rating (IEC 60529)

IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC)

Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC)

Yes

Optional Properties Heliostat usage

Yes

CPV usage (concentrated PV usage)

Yes, all types including round parabolic

Guarantee time

2 years as standard, 5 years for +20% *** 10 years for +35% ***

64


5. SOLAR POSITIONERS 5.a. SOLAR POSITIONER NANO

Product code: POZSOL34A1DR (Solar Positioner NANO works only in connection with Solar server SIGMA!!!)

Solar Positioner NANO A for Dual Axis Tracking With even better communication, usability and accuracy, the Solar Positioner NANO A set a new Positioning Accuracy Standards. With easy installation, safe operation, a simplified assembly concept, and RS485 plant communication: the new generation of positioners is ideally suited in mid-sized and large stand-alone grids. With the Sigma Server, Solar Positioner NANO A creates complete, integrated system for monitoring, diagnosis and configuration of the PV plant. Professional • Drive and positioning of Dual Axis Solar Trackers • Integration of Sat Control equipment into existing control-room technology Flexible • Data interface in accordance with the communication standards in the field of automation technology • Simple and fast installation, high reliability

65

Reliable • Direct communication with the Sigma Solar Server via RS485 Service Interface • Meets the requirements of the EU Medium-Voltage Directive for grid safety management


5. SOLAR POSITIONERS 5.a. SOLAR POSITIONER NANO Technical Capabilities Operation Geometrical Operation

Dual Axis Positioner

Type

Slave Positioner

Communication Tracker communication

RS485 MODBUS

Interfaces RS485

2 Pin Connector (Grounding Option)

Max. number of controlled devices Solar Tracker

64

Max. communication range RS485

1000 m

Power supply Power supply

External Power Supply

Input voltage

24VDC +/- 10%

Power consumption

Type 4 W / max. 12 W / 0,5 W Stand By

Environmental conditions in operation Ambient temperature

-20 °C ... +60 °C

Relative air humidity

0 % ... 45 %, non-condensing

General data Dimensions (W / H / D) in mm

110 / 55 / 17

Weight

100 g

Mounting location

Indoors

Mounting options

DIN rail mounting

Status display

LEDs

Hall signals

2 Hall signals per Axis

End switches

2 Switches per Axis (one required, one optional)

Manual buttons

2 (East-West, Reference)

Upgrading

In The Field by RS485 MODBUS

Languages Software language

English

Language versions – manual

German, English, French, Italian, Spanish; Slovenian

Features Warranty

5 years

Certificates and approvals

www.Solar-Motors.com

66


5. SOLAR POSITIONERS 5.b. SOLAR POSITIONER MICRO

Product code: POZSOL36A1DR Solar Positioner MICRO (stand alone positioner) is settable with Helios Analytics monitoring programme!!!

Solar Positioner MICRO for Dual Axis Tracking With even better communication, usability and accuracy, the Solar Positioner MICRO set a new Positioning Accuracy Standards. With easy installation, safe operation, a simplified assembly concept, USB tracker and RS485 plant communication: the new generation of positioners is ideally suited in single and middle size standalone grids. With the Sigma Server, Solar Positioner MICRO creates complete, integrated system for monitoring, diagnosis and configuration of the PV plant. Professional • Drive and positioning of Dual Axis Solar Trackers • Integration of Sat Control equipment into existing control-room technology Flexible • Data interface in accordance with the communication standards in the field of automation technology • Simple and fast installation, high reliability Reliable • Direct communication with Helios Analytics • Meets the requirements of the EU Medium-Voltage Directive for grid safety management

67


5. SOLAR POSITIONERS 5.b. SOLAR POSITIONER MICRO Technical Capabilities

Operationnergy measurement of two equal solar panels (fixed and motorized)

Operation

Geometrical Operation

Dual Axis Positioner

Stand Alone Positioner Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Tracker communication USB, RS485 MODBUS Test conditions: Interfaces Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) RS485 2 Pin Connector (Grounding Option) Date: July 2010 Max. number of controlled devices Time: 4:00 to 20:00 (sun time) Solar Tracker 1 Geo. Latitude: 46° N Max. communication range Weather conditions: sunny, but not totally1000 clear RS485 m Results: Power supply Average energy of fixed: 3762,0Wh Power supply External Power Supply Average energy of motorized: 6093,0Wh 24VDC +/- 10% Input voltage Power consumption 2Type 4 W / max. W / 0,5 W By Note: sum of motor energy consumption through all12 day isStand 17.52Wh or 0.29% of all colEnvironmental conditions in operation lected energy. Ambient -20 °Cbetter ... +60 °C axistemperature or dual axis Solar Tracker with accuracy than 0,5 deg and backstructure for 3 Relative air humidity % ... 45 %, non-condensing pieces of solar panels dimensions 0,99 m x 01,95 m and weight of 30 kg max each. So toGeneral data gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helioDimensions (W / H / D) in mm 110 / 55 / 17 stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cotType

Communication

Weight

100 g

Mounting location

Indoors

Mounting options

DIN rail mounting

Status display

LEDs

Hall signals

2 Hall signals per Axis

End switches

2 Switches per Axis (one required, one optional)

Manual buttons

2 (East-West, Reference)

Upgrading

In The Field by RS485 MODBUS, or by USB

Languages Software language

English

Language versions – manual

German, English, French, Italian, Spanish; Slovenian

Features Warranty

5 years

Certificates and approvals

www.Solar-Motors.com

68


5. SOLAR POSITIONERS 5.c. Sigma Solar Server

Product code: POZSOLSIG1 (Sigma Solar Server works in connection with Solar Positioner NANO!!!)

The standardized data interface for large-scale systems Large-scale plants and PV power utility stations require customized monitoring solutions and need to link systems and components into one joint control system. Sigma Server set new communication standard in the field of automation technology, that enables simple and reliable data exchange between products and applications. With the Sigma Solar Server, Sat Control equipment can be very easily integrated into compatible systems. Overview Professional • Visualization, control and monitoring of large-scale plants • Integration of Sat Control equipment into existing control-room technology Flexible • Data interface in accordance with the communication standards in the field of automation technology • Simple and fast installation, high reliability

69


5. SOLAR POSITIONERS 5.c. Sigma Solar Server Technical Capabilities

2 Real energy measurement of two equal solar panels (fixed and motorized)

Communication

Communication with Enigma Analytics

Ethernet

Ethernet Three equal solar panels were exposed to the real sun and conversed electrical power was RS485 measured. Interfaces Test conditions: Analog and digital inputs 3 analog inputs / 3 open collector outputs Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Ethernet 10/100 Mbit, RJ45 Date: July 2010 RS485 2 Pin Connector (grounding option) Time: 4:00 to 20:00 (sun time) Max. number of controlled devices Geo. Latitude: 46° N Solar Tracker 64 Weather conditions: sunny, but not totally clear Max. communication range Results: Ethernet 100 m Average energy of fixed: 3762,0Wh RS485 1000 m Average energy of motorized: 6093,0Wh Power supply Power supplysum of motor energy consumption through External Power Supply Note: all day is 17.52Wh or 0.29% of all colInput voltage 12VDC 24VDC lected energy. Power consumption Type 4 W / max. 12 W axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 Environmental conditions in operation pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So toAmbient temperature -20 °C ... +60 °C gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helioRelative air humidity 0 % ... 45 %, non-condensing stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cotPC communication

Tracker communication

Memory Internal

0,5 MB

External

SD card 2 GB

General data Dimensions (W / H / D) in mm

110 / 55 / 17

Weight

100 g

Mounting location

Indoors

Mounting options

DIN rail mounting

Status display

LEDs

Languages Software language

English

Language versions – manual

German, English, French, Italian, Spanish; Slovenian

Features Operation

Integrated Web server (Internet browser)

Warranty

5 years

Certificates and approvals

www.Solar-Motors.com

70


5. SMPS Power supply TDK 5.d. Lambda; 1. DPP 50-24, 2. DPP 100-24, 3. DPP 480-24-3 1. TDK - Lambda DPP 50-24 A 50 watt, enclosed frame, single output DIN Rail mounted AC/DC power supply. This rail mount power supply has a 85-264 AC volt Wide-range input with power factor correction. The output(s) are rated 24.00v at 2.10a. It is industrial rated with an operating temperature range of -10 - 71 °C and up to 86% efficiency. The DPP50-24 is Rohs 6/6 compliant and backed by a 2 year warranty.

Overview: • • • • • • • • • •

5 to 48 V Outputs 50 mV Ripple and Noise Parallel Up to 3 Units (100 W and Up) Convection Cooled from –10°C Up to +71°C Active Power Factor Correction (PFC) Universal/Auto Select AC Input Input Transient Protection IEC61000-4 UL/CSA/EN60950-1 and CE Mark Safety Approvals UL1310 Class 2 UL508 Listed and Class 1, Div. 2

3. TDK - Lambda DPP 100-24 A 100 watt, enclosed frame, single output DIN Rail mounted AC/DC power supply.

Overview: • • • • • • • • • • • • • • •

71

PSU, AC/DC, DIN RAIL, 24V, 100W Power Supply Output Type: Adjustable No. of Outputs: 1 Output Voltage: 24V Output Current: 4.2A Power Rating: 100W Input Voltage VAC: 85V AC to 132V AC/170V AC to 264V AC Length: 96.7mm Width: 22.8mm Height: 75mm SVHC: No SVHC (20-Jun-2011) Efficiency: 87% Input Voltage: 85V AC to 132V AC , 170V AC to 264V AC Output Voltage Max: 28.5V Output Voltage Min: 22.5V


5. SMPS Power supply TDK

Technical Capabilities 2. TDK - Lambda DPP 480-24 (DIN Rail solar 24V 20A 480W) Operationnergy measurement of two equal panels (fixed

and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was A 480 watt, enclosed frame, single output DIN Rail mounted AC/DC power supply. measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: Overview: July 2010 Time: • PSU, AC/DC, DIN 4:00 to 20:00 (sun time) RAIL, 24V, 480W, 3PH Geo. Latitude: 46° N • Power Supply Output Type: Fixed Weather• conditions: but not totally clear No. of Outputs: sunny, 1 Results:• Output Voltage: 24V Average• energy of fixed: Output Current: 20A 3762,0Wh Power Rating: 480W Average• energy of motorized: 6093,0Wh • Input Voltage VAC: 340V AC to 575V ACthrough all day is 17.52Wh or 0.29% of all colNote: sum of motor energy consumption • Length: 111.9mm lected energy. Width: 150mm axis or •dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 • Height: 124mm pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to• SVHC: No SVHC (20-Jun-2011) gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio• Efficiency: 90% stats. Usage homes: on-grid at roof • Inputat Voltage: 340V AC to 575V AC on houses, trafic signalisations, street light, cot• Output Voltage Max: 28.5V • Output Voltage Min: 22.5V

72


5. JUNCTION BOX 5.e. Junction Box (j-box) Set

Product code: JBOXSETSPMN1-TC

Junction Box (j-box) Set - Smart solution for solar tracker positioner connection The Sat Control’s Junction Box (j-box) Set is designed to be compact and versatile without any compromise on its safety and reliability standards: Expanding on the proven technology of Sat Control’s positioning devices, it separate of both mechanical and electronic components of solar trackers and replaces Sat Control’s integrated positioner with external din rail positioners. Material wall mounting boxes: made of ABS technopolymer with high resistance to UV rays and broad temperature range enable its use even under extreme climatic conditions. Particular bottom guides for DIN rail, terminal block and plates enable its easy installation and make positioner settings entirely foolproof. User-friendly • Separate of both mechanical and electronic components • Easy status reports and visualization via Transparent Lid • Can be integrated into existing and new Solar Trackers/PV plants Simple • Easily accessible connection area • Comfortable installation and commissioning • Free choice of mounting location Durable • High protection class IP65

73


5. JUNCTION BOX & CONNECTION BOARD SESTIV 39B 5.e. Junction Box (j-box) Set Technical Capabilities General data energy 2 Real

measurement of two equal solar panels (fixed and motorized)

Internal dim. (W / H / D) in mm Weight (without cables) Max ø holes possible Lid screws (no. and type) Characteristics Mounting site Mounting options

190 / 140 / 70 500 g 4 x ø 18 mm 4 Insulated sealable Hinged (Inox) Halogen Free outdoors DIN-Rail mounted interfaces

Int. Cable SM4M3 w con 7pins->OPEN, L=opt. 2x1+5x0.22

opt. (1 or 2 pcs depend on Actuators - length is at request)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Ambient Conditions Date: July 2010 Ambient temperature -40 °C ... +85 °C / -40 °F ... +185 °F Time: 4:00 to 20:00 (sun time) Relative air humidity 100 % relative humidity (non-condensing) Degree of protection (according to IEC 60529)46° N IP65 Geo. Latitude: Features Weather conditions: sunny, but not totally clear Smooth Sided junction box - Screwed Transparent Lid - IP 56 1 Results: Din metal mounting rail 180(L) mm 1 Average energy of(16fixed: Metric Thread Cable Glands Pg 9 TD mm) TL (8 mm) 3762,0Wh 4 DIN Rail Mounted Fuse Holder VSV 4 4 mm2 440 V 1 Average energy of motorized: 6093,0Wh DIN Rail Terminal Block VS 4-PE 4 mm 1 Note: sum ofBlock motor all day is 17.52Wh or 0.29% of all colDIN Rail Bus bar Terminal 6x9 -–10P energy consumption through 2 Warranty: 5 / 10 / 15 / 20 / 25 years yes / opt. / opt. / opt. / opt. lected energy. Certificates and approvals www.Solar-Motors.com axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 Accessories pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So toPositioners Solar Positionerfor 2-axis5,8 mod. MICRO, DIN rail opt. gether m2USB-RS485, solar panel surface. A Suitable for PV panels, concentrators - CPV, helioSolar Positioner 2-axis mod. NANO, RS485, DIN rail opt. stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cotCables

5.f. Connection Board Sestiv 39B Product code: SESTIV39B

74


5. USB 2.0 to RS485 5.g. USB 2.0 to RS485 Mini Adapter with Terminal Block

Product code: USB2RS485

USB 2.0 to RS485 Mini Adapter with Terminal Block Specifications • • • • • •

USB Specification 2.0 Compliant Supports RS485 serial Interface Data Transfer Rates from 300bps to 3Mbps Enhanced ESD Specification: +/-15KV Human Body Model, +/-15KV IEC1000-4-2 Air Discharge, +/-8KV • IEC1000-4-2 Contact Discharge Supports Windows 98SE/ME/2k/XP/Vista/7/x64, Mac OSX, Linux 2.6.9+

Includes • • • •

75

USB to RS485 Adapter DB9 to 4-pin Terminal Block adapter Driver Disk 0,8m USB extension cable


5. CABLE USB2.0 - USB-A 5.h. Cable USB2.0 - USB-A -> Micro-B, 1,8m, black Technical Capabilities

2 Real energy measurement of two equal solar panels (fixed and motorized) Product code: KABUSBA-MB1.8

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-

Cable USB2.0 - USB-A -> Micro-B, 1,8m, black Specifications • • • • • • • •

CABLE, USB A M - MICRO B M, 1.8M Cable Assembly Type:Computer Cables Cable Length - Metric:1.8m Cable Length:1.8m Colour:Black Connector Type A:USB A Male Connector Type B:USB micro B male Weight (kg): 0.06

76


5. WIND SENSOR 5.i. Wind sensor WS XS Vestamatic

Product code: WSVM01100310

Wind sensor WS XS Vestamatic Specifications • Wind sensor for measuring wind speed • For plastic bracket mounting • Compatible with all Vestamatic central, awning and blind controls Includes • Wind sensor WS XS Vestamatic WSVM01100310 / 383106390209

77


5. CABLE USB2.0 - USB-A 5.j. Plastic mounting bracket for wind sensor Technical Capabilities

2 Real energy measurement of two equal solar panels (fixed and motorized) Product code: WSBWM01271020

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-

Wind sensor WS XS Vestamatic Specifications • Wind sensor for measuring wind speed • For plastic bracket mounting • Compatible with all Vestamatic central, awning and blind controls Includes • Wind sensor WS XS Vestamatic WSVM01100310 / 383106390209

78


6. GROUND SCREWS 6.a. Ground Screw

Product code: ZV76X60X1400

Ground Screws Ground Screws made of high quality hot-galvanized steel, are widely used as strong supports for many applications: flag poles and masts, timber construction, fencing systems, event structures, boards and banners, gardens and parks, Roads and traffics, sheds and containers etc. For us the important thing is they can be the easy and strong support for Solar Trackers and PV systems. Key Features • • • • •

Foundation screws for any type of soil Ideal for Photovoltaic Installations Solid, forged and galvanized steel with welded screw threads Stability is accomplished by means of compression during insertion to the ground. No other digging is required. Production process is certified ISO9001:2008, ensuring the highest quality construction, reliability and flexibility.

Advantages • • • • • • • •

79

No cement foundation or any other concrete construction needed Optimum earthing accomplished by connecting the vertical parts with tin-plated copper wire, avoid ing any additional ground wiring, creating that way a solid, low resistance grounding Ground screws come with a 25-yeat anti-corrosion guarantee No construction permit required All systems are adjustable to customer requirements. All systems are assembled using specialized personnel and machinery Time saving and cost efficient Can be subject to weight loads immediately Environmentally friendly


6. GROUND SCREWS 6.a. Ground Screw

Technical Capabilities Model type

Ground screw 76X1400 L=1400 d=76/60

Length of ground screw

1400 mm

Outside diameter of ground screw

76,45mm x 2,6 mm (inner dia. 71mm with zinc)

Max. diameter of tube you can put in

D63,5 mm L=2m

Screw thread size and pitch

620 mm

Surface treatment protection type and thick

Hot bath zincking 200 um EN ISO1461

80


6. GROUND SCREWS 6.a. Ground Screw

81


6. GROUND SCREWS 6.b. SET Ground Screws

Product code: SETZV14C2X1SP

SET Ground Screws SET Ground Screws provide a solid foundation whatever your project needs. Our SET Ground Screws is engineered for easy installation and provide years of dependable service. There is no need for gigging or laying a concrete foundation, drastically reducing cost and time associated with installation. SET Ground Screws also lessen the environmental impact of your solar project, allowing your panel arrays to blend in more naturally into terrain. Also importantly, SET Ground Screws are easily removable and reusable. Set Components are: • • •

Ground Screw: 76x1400mm Tube D60 2x1000 mm Junction Clamp d=76/60

Key Features Convenience • • • • •

Easy to install and use No gigging or poring of concrete needed Can be used in all types of soil Fastest possible installation time Ready to use immediately after installation

Environmentally friendly • • •

Compact design ensures the least impact on ground and surrounding area Minimal site preparation needed Since there is no need for concrete, the ground remains intact after screws are removed

Durability • • • •

Made with galvanized steel and welded screw threads Can be subject to weight loads immediately after installation Provides solid foundation in all weather conditions 25-year anti-corrosion guarantee

Value • • • •

Reduced installation time and cost Minimal materials required; provides the most cost effective foundation solution Lowers system buy back times Removable and reusable

82


6. GROUND SCREWS 6.b. SET Ground Screws

Product code: SETZV14C2X1SP

Technical Capabilities

83

Model type

SET Ground Screws 76x1400 with tube D60 2x1000 with junction clamp

Length of ground screw

1400mm + 2 x tube D60,3 x 1000 + junction clamp

Outside diameter of ground screw

76,45mm x 2,6mm + 2 x D60,3 x 3,25mm

Max. diameter of tube you can put in

D63,5 x 3,25mm L=2000mm

Screw thread size and pitch

620mm

Surface treatment protection type and thick

Hot bath zincking Zn 200 um EN ISO1461


6. GROUND SCREWS 6.b. SET Ground Screws

84


7. MONITORING SYSTEM - Helios Analytics 7.a. Helios Analytics

Product code: PRGSIGHELANA1

Professional management, monitoring and presentation of solar tracker System management, monitoring, remote diagnosis, data adjusting and visualization: the Helios Analytics is the high-performance communication hub for single- to small-scale of solar trackers. It continuously display all the data from the solar trackers on the system side, thereby keeping you informed of the system‘s status at any given time. The Helios Analytics is a multi-functional, energy-efficient data system which offers importing and exporting settings data for solar trackers. Overview Safe • Remote monitoring, diagnosis and configuration of the solar trackers • Quick detection of malfunctions and notification in case of a failure • Powerful data system for importing and exporting all trackers setting data User-friendly • Central administration of all customer and tracker data • Easy remote access via PC • Easy to understand reporting

85


7. MONITORING SYSTEM - Helios Analytics 7.a. Helios Analytics Technical Capabilities

2 Real energy measurement of two equal solar panels (fixed and motorized) Languages

Three equal solar panels were exposed to the real sun and conversed electrical power was German, English, French, Italian, Spanish, Slovenian measured. System requirements Test conditions: Windows XP (installed version of Microsoft .NET Framework > 2.0 is Supported systems required with 64spec. bit systems), Windows (32-Bit and 64-Bit), Solaroperating panels (both): 0.9 kWp (producer at AMVista 1.5) Windows 7 (32-Bit and 64-Bit) Date: July 2010 Hardware (minimum requirements) Time: 4:00 to 20:00 (sun time) Processor PIII 800 MHz (XP) / P4 1 GHz (Vista) Geo. Latitude: 46° N Main Memory 512MB (XP) / 1 GB (Vista) Weather conditions: sunny, but not totally clear Free hard disk space 265 MB (240 MB .Net / 25 MB application) Results: Resolution 1024 x 768 pixels Average energy of fixed: 3762,0Wh Color depth 256 colors Average energy of motorized: 6093,0Wh Communication Tracker communication USB 2.0, CANthrough BUS 2.0 A Note: sum of motor energy consumption all day is 17.52Wh or 0.29% of all colType IP address, URL (e.g., DynDns) lected energy. Max. number axis orof devices dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 USB 2.0 / CAN BUSsolar 2.0 A 1 / up to 2000 pieces of panels dimensions 0,99 m trackers x 1,95 m and weight of 30 kg max each. So toRS485 / Ethernet / gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helioMax. communication range stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cotSoftware language

English

Language versions – manual

USB 2.0 / CAN BUS 2.0 A

5 m / 500 m (Twisted Pair Cable with cross section 0,7 mm2)

RS485 / Ethernet

/

Software Type

Exe

Other

Zip

Client Software Requirements

No installation-dependent requirements for the operation

System information Tracker overview

Ideally suited for an overview over the solar tracker by presentation of the most important data

System settings

Simple parameter setting for an entire device

Current system values

Summary of current device data. The display of minimum and maximum values, sums and averages (depicted for every device category) provides the operator with detailed information about the current status of their solar tracker

Device information Device overview

The most important device information at a single glance

Device settings

Individual parameter adjustment for each device

Current device values

Detailed information on the current values of the selected device

Information displayed General information

Time, date

System Data

Power supply voltage, current motion, position, error codes, angle, tracker version, tracker type

Advanced System Data Motor A

A1, A2, A3, A4, A5 , A6, B1, B2, min range A, max range A, gear ratio A, I motor max A, coordinate mode A, geometry mode A, I motor factor A, night position A, go to reference A

Motor B

A1, A2, A3, A4, A5 , A6, B1, B2, min range B, max range B, gear ratio B, I motor max B, coordinate mode B, geometry mode B, I motor factor B, night position B, go to reference B

Common settings

Night position time, link, U supply factor , group, conf. flags, SN1, SN2, SN3, can ID, options, run, delay n.p., run delay, panel wide, panel space, rtc correction, H target angle, V target angle

Individual set-up options Values

Three configurable pre-defined positions for snow, wind, etc.

The weather station for PV plants Current system values

/

86


8. SAT CONTROL WEBSHOP 8.a. Sat Control WebShop

Profit from our new online shop! Conveniently order Sat Control quality from home and profit from: • A wide range of products and services • Surprisingly low prices • The high level of quality of quality of the products and components used and • The schedule effectiveness you have become accustomed to The Sat Control WebShop. 24/7 one-stop shopping for all-round solutions Tailor-made to your needs fast and at the same level of high quality.

87


8. SAT CONTROL WEBSHOP 8.a. Sat Control WebShop 2 Making Real energy measurement of two equal solar panels (fixed and motorized) a Payment Three equal solar panels were exposed the real sun and conversed electrical was The following outlines the how you can make ato payment through the WorldPay Payment Servicepower and how we deal with the transaction. measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-

How does the WorldPay Payment Service work? 1. A shopper visits an e-commerce website and selects the products/services that they would like to buy. 2. The shopper then proceeds to the merchant’s checkout with their shopping basket. This generates a summary description of the purchase that is sent to WorldPay for payment processing. This submis sion is often referred to as the “purchase token”. 3. The shopper is redirected to WorldPay’s secure server where they are presented with a series of payment pages, enabling them to choose their payment method and enter their payment details. 4. WorldPay records the shopper’s payment details against the details submitted in the purchase token, to produce a transaction. 5. WorldPay forwards the transaction details to the card issuer for authentication. The issuer returns an authorised or declined response to WorldPay and a payment response page is then displayed to the shopper. 6. If the transaction was successful, WorldPay will also send the shopper a confirmation email, confirming the transaction details. For more informations about paying through WorldPay, and for information on the status of your payments for purchases made at one of the shops that uses the WorldPay Payment Service, please visit: www.rbsworldpay.com

88


Published by and copyright Š 2011: Sat Control d.o.o. Pozenik 10, SI-4207 Cerklje Slovenia For more information, please contact our Customer Support Center. Phone: +386 4 281 62 15 Fax: +386 4 281 62 13 (Charges depending on provider) E-mail: support@sat-control.si Order No. PC2011-V1.1 Printed in Slovenia Dispo 34807, c4bs No. 7827 fb 2674 440101 WS 11092.0 Printed on elementary chlorine-free bleached paper. All rights reserved. Trademarks mentioned in this document are the property of Sat Control d.o.o., its affiliates, or their respective owners. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract.


Turn static files into dynamic content formats.

Create a flipbook