MiNi

Page 1

MiNi

TM

MiNi

TM

Strong Solution for Narrow Ridge. Volume MiNi C3.0

Gangnam Office 5F MegaGen Tower, 607 Seolleung-ro, Gangnam-gu, Seoul, Korea Head Office & Factory 472 Hanjanggun-ro, Jain-myeon, Gyeongsan, Gyeongbuk, Korea

www.imegagen.com

T. +82-1566-2338 T. +82-1544-2285


➲ Features MiNi, but mighty

- MiNi was designed for your convenience with better reliability. When compared with the company A, MiNi Ø3.0 has similar compressive strength, but Ø3.25 showed much higher value of strength on the thin wall area of the fixture. TM

TM

800

784.4

750 700 650

676.6

657.1

Load (N)

600 550 500

MiNiTM Ø3.0 Ø3.0

MiNiTM Ø3.25 Ø3.4

A B

MiNiTM Ø3.0

11˚connection M1.4 Abutment Screw

Company A Ø3.0 Ø3.0

A

A

B

B

MiNiTM Ø3.25

Company A Ø3.0

Parallel wall thickness

MiNiTM Ø3

MiNiTM Ø3.25

Company A Ø3

A

0.28

0.47

0.34

B

0.31

0.42

0.44

1.7mm Hex

XPEED Surface treatment Knife thread


MiNi 02 /03 TM

➲ Fixture Size Ø3.0

Diameter

Length(mm)

Ref.C

Ø3.0

Ø3.25

Diameter

8.5

MIIF3008C

10.0

MIIF3010C

11.5

MIIF3011C

13.0

MIIF3013C

15.0

MIIF3015C

Length(mm)

Ref.C

8.5

MIIF3308C

10.0

MIIF3310C

11.5

MIIF3311C

13.0

MIIF3313C

15.0

MIIF3315C

Ø3.25

➲ Cover Screw &

Healing Abutment

Cover Screw

Height(mm)

Ref.C

0.5

MICS2505

Ø3.0

Length

Ø3.4

Length Ø3.25

Height

Top view

• Recommended torque - Manual (5~10 N∙cm)

Healing Abutment

Profile Diameter

Ø3

Profile Diameter

Ø3.5

Cuff Height(mm)

Ref.C

1.0

MIHA3025

1.5

MIHA3030

2.5

MIHA3040

3.5

MIHA3050

4.5

MIHA3060

Cuff Height(mm)

Ref.C

1.0

MIHA3525

1.5

MIHA3530

2.5

MIHA3540

3.5

MIHA3550

4.5

MIHA3560

• Recommended torque - Manual (5~10 N∙cm)

Cuff Height

Cuff Height


➲ Fixture Length and Drill Marking The platform line of the Handpiece Connector or the Ratchet Connector must be seated flush to the fixture platform.

3mm 0.5mm

When using the Ratchet Wrench, do not use an excessive torque as it can lead to a failure of internal structural damage to the fixtures, It is not recommended to exceed the maximum torque of 75N·cm.

15.0mm

0.5mm

0.5mm Subcrestal

Ø3.0

14.5mm

11.0mm

9.5mm

8.0mm

11.5mm 10.0mm 8.5mm

12.5mm

13.0mm

Fixture length 9.5mm

Y value 0.5mm

The actual lengths of MiNi internal fixture is 0.5mm shorter than the depth markings of a shaping drill. Therefore, the fixture will be placed 0.5mm under the crest naturally.

Actual drilling depth 10.5mm = 0.5mm subcrestal + 9.5mm actual fixture length + 0.5mm Y value * Ø3.0 (Y value = 0.5mm), Ø3.25 (Y value = 0.586)

TM

➲ Surgical Drilling Sequence Ø2.0

Initial Drill

Ø2.5

Ø2.0

Ø2.5

Ø2.8

Actual drilling depth 10.5mm = 0.5mm subcrestal + 9.5mm actual fixture length + 0.5mm Y value

Ø3.25

Actual drilling depth 10.5mm = 0.5mm subcrestal + 9.5mm actual fixture length + 0.586mm Y value

9.5mm

mm 0.5

10.0mm

9.5mm

Ø3.0

mm 0.5

10.0mm

Initial Drill


MiNi 04 /05 TM

➲ Surgical Kit (KMIIP3000)

Hand Driver

Initial Drill

Shaping Drill

Handpiece Connector

Ratchet Connector


➲ Surgical Instruments Initial Drill

Handpiece Connector

Diameter

Length(mm)

Ref.C

Ø1.8

33

ID1818S

Hex Size(mm)

Type

Ref.C

Short

HCS17

Long

HCL17

Length(mm)

Ref.C

Short

RCS17

Long

RCL17

Length(mm)

Ref.C

1.7

Ratchet Connector

Hex Size(mm)

1.7

Shaping Drill

Diameter

Ø2.0

SD2018S 33

Ø2.5

SD2518S

Ø2.8

Hand Driver

SD2818S

Type

Length(mm)

Hex

Ref.C

Long

15

1.2

TCMHDL1200

Length


MiNi 06 /07 TM

➲ Prosthesis

EZ Post

Milling Abutment

Temporary Abutment

Angled Abutment

Fuse Abutment

Lab Analog Closed tray / Simple case

Open tray / Complicated case

Impression Coping (Transfer)

Impression Coping (Pick-up)

Ø3.25

Healing Abutment

Ø3.0

Cover Screw


➲ Prosthesis Options EZ Post

Profile Post Cuff Height Diameter Height(mm) (mm)

- Abutment Screw(MIAS14) included

Ø3.5

5.0

Ref.C

1.0

MIEP3505HT

1.5

MIEP3515HT

2.5

MIEP3525HT

3.5

MIEP3535HT

4.5

MIEP3545HT

Post Height

Profile Diameter

• Recommended torque - 15 N∙cm

Profile Post Cuff Height Diameter Height(mm) (mm)

Ø3.5

7.0

Ø3.5

9.0

Ref.C

1.0

MIEP3507HT

1.5

MIEP3517HT

2.5

MIEP3527HT

3.5

MIEP3537HT

4.5

MIEP3547HT

Profile Post Cuff Height Diameter Height(mm) (mm)

Cuff Height

Post Height

Cuff Height

Profile Diameter

Ref.C

1.0

MIEP3509HT

1.5

MIEP3519HT

2.5

MIEP3529HT

3.5

MIEP3539HT

4.5

MIEP3549HT

Post Height Cuff Height

Profile Diameter


MiNi 08 /09 TM

Milling Abutment

Profile Post Cuff Height Diameter Height(mm) (mm)

- Abutment Screw(MIAS14) included

Ø3.0

5.0

Ref.C

1.0

MIMA3005HT

1.5

MIMA3015HT

2.5

MIMA3025HT

3.5

MIMA3035HT

4.5

MIMA3045HT

Post Height

Cuff Height

Profile Diameter

• Recommended torque - 15 N∙cm

Profile Post Cuff Height Diameter Height(mm) (mm)

Ø3.0

7.0

1.0

MIMA3007HT

1.5

MIMA3017HT

2.5

MIMA3027HT

3.5

MIMA3037HT

4.5

MIMA3047HT

Profile Post Cuff Height Diameter Height(mm) (mm)

Ø3.0

Angled Abutment

Type

- Abutment Screw(MIAS14) included

9.0

1.0

MIMA3009HT

1.5

MIMA3019HT

2.5

MIMA3029HT

3.5

MIMA3039HT

4.5

MIMA3049HT

Ref.C

2.5

MIAA3215HT

3.5

MIAA3315HT

Ø3.5

4.5 2.5

15°

Cuff Height

Profile Diameter

Post Height

Cuff Height

Profile Diameter

Post Angle

Post Angle

Cuff Height

MIAA3415HT

Cuff Height

MIAA3215ET

3.5

MIAA3315ET

4.5

MIAA3415ET

• Recommended torque - 15 N∙cm

Post Height

Ref.C

Profile Cuff Height Post Diameter (mm) Angle

Hex

Hex-E

Ref.C

Profile Diameter

Profile Diameter Hex

Hex-E


➲ Prosthesis Option Temporary Abutment - Abutment Screw(MIAS14) included

Profile Diameter

Length(mm)

Ref.C

Ø3.0

12

MITA3012HT

Length

• Recommended torque - 10~15 N∙cm

Profile Diameter

Fuse Abutment

- Abutment Screw(MIAS14) + Fuse Cap included

Type

Straight Angled(15°)

Labiolingual

Mesiodistal

Ø5.0

Ø3.5

Cuff Height (mm) (mm)

3.5

7.0

Ref.C

MFAP3535P

Mesio-distal Post Angle

MFAA3315P

Labio-lingual

• Recommended torque - 10~15 N∙cm

Height Mesio-distal

Cuff Labio-lingual

Transfer type

Impression Coping - Guide Pin included

Profile Diameter

Type

Transfer

Ø3.5

Pick-up

Length(mm)

Ref.C

14

MIIT3516HT

16

MIIP3516HT

• Guide Pin Transfer type - MIGPT16 Pick-up type - MIGPP16

Lab Analog

Pick-up type

Profile Diameter

Length(mm)

Ref.C

12

MILA300H

Length

Length

Profile Diameter

Length


MiNi 10 /11 TM

➲ Case Report

Fig 1. Preoperative panoramic radiograph and intraoral photos. The ridge was atrophied due to long-term absence of teeth.

Fig 2. Flap was elevated and two osteotomy sockets were made for 3.0mm MiNiTM fixtures. There was enough bone left in labio-lingual area for slim fixture.

Fig 3. Two 3.0 x 15.0 mm MiNiTM implants were placed with excellent stability. GBR was not reguired.

Fig 4. Two pieces EZ Post were connected to make temporary prosthetics for immediate provisionalization.

Fig 5. Flap was sutured and EZ Posts were milled for the better path.

Fig 6. Provisional restoration was made at the chair side. Due to the smaller diameter of fixture and abutment, the prosthetics could have a nice emergence profile.

Fig 9. Clinical photo and intraoral Fig 7. Clinical photo and intraoral Fig 8. Clinical photo and intraoral radiograph 1 month after radiograph after final restoration. radiograph right after surgery. surgery.


MiNi

TM

MiNi

TM

Strong Solution for Narrow Ridge. Volume MiNi C3.0

Gangnam Office 5F MegaGen Tower, 607 Seolleung-ro, Gangnam-gu, Seoul, Korea Head Office & Factory 472 Hanjanggun-ro, Jain-myeon, Gyeongsan, Gyeongbuk, Korea

www.imegagen.com

T. +82-1566-2338 T. +82-1544-2285


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.