AC SP
BR ON X
t ar
Building Systems 2 - Fall 2009
E
f.09
Bs2
Building Systems 2 Anton Martinez
Critic: Anton Martinez with Elias Matar Team: Yuval Borochov, Debbie Lin, Jessica Helfand-Talley Project: Design of an Industrial Loft Building Our design efforts focused on providing a lattice for crawling plants to grow over the facade of the building, giving access to light and air filtered through green plants to the majority of spaces in the building. Artists working within the building are supported by a variety of production and display spaces for individual and collaborative work. Integral to this are the public gallery spaces and access within the building which allow artists to promote their work to a wide audience, while the public can learn production techniques. The plants are supported on a lattice over tension cables, supported by steel struts which connect it back to the building structure at the floor levels. An aluminum cover conceals the cable connections and a sprinkler system to water the plants. The cables keep the external structure light weight, and their flexibility allows for variety within a simple diamond-shape formal vocabulary across the facade.
BR ON X
AC SP
t ar
t ar
BR ON X
E ey
v all ho d-T
De ich M
5 roc an p Bo Helf h ou val ica Lin alc Gr YuJess bbie ael W
b a De ich M
LIN. RETURN DIFFUSER SEE MECH. PLANS
STL. BEAM DECK ABOVE
24” X 24” ACCESS PANEL LIN. RADIANT PANEL SFC-MTD TRACK LIGHTING HVAC SUPPLY DUCT RECESSED DOWN LIGHTING INTERNAL LOUVERS IN REMOVABLE FRAME
LINEAR RADIANT HEAT PANEL
OPERABLE AWNING WINDOW
SPRINKLER HEAD
GYP. BD. SOFFIT
ALUMINUM MULLION
FRAMELESS GLASS DOOR
LINEAR SUPPLY DIFFUSER SEE MECH. PLANS
Typical Floor Plans of Studios 3/4” = 1’-0”
3/4” = 1’-0”
3/-
3/8” = 1’-0”
VAV BOX BRANCH DUCT
ALUMINUM FRAMED GLAZING
MAIN SUPPLY DUCT
GLASS DOOR
RETURN PLENUM
5/-
GYP. BOARD CLG. WITH STL. FRAMING EACH SIDE 3 5/8” METAL STUD @ 16” O.C. CONT. TO UNDERSIDE OF DECK ABOVE
4/-
3/8” = 1’-0”
Ground Floor Plan
A1 Floor Plans
3/4” = 1’-0”
Studio space enlarged plans and sections
A
Sin
X BR ON
tS
ar
R25.00
Gr
Yu ssi bie l W Je eb ae D ich M
R25.00
R5.00
R25.00 R25.00 R25.00
3
Elevation Detail at Aluminum Cable Cover Type A NTS
ey v all ho d-T
BR ON
2”
2’-2”
1’-0”
1’-4”
5”
E
Elevation Detail at Aluminum Cable Cover Type B NTS
s ie l Je ebb ae D ich M
5
ANCHOR TO STRUCTURE BEYOND
Y
Plan at Exposed S.S. Connec on to Structure
DETAIL B AT S.S. CABLE CONNECTION
Elevation Detail at Aluminum Cable Cover Type CCOVER CONNECTION, CUSTOM EXPOSED S.S. CABLE AND CABLE
DETAIL A AT S.S. CONNECTION TO COVER PLATE NTS
7
R25.00
5 roc an p Bo Helf h ou uval sica Lin Walc
5’-0” OR 20’-0” TYPICAL, SEE ELEVATIONS
HALF SCALE
0.25” DIAMETER STEEL CABLE, STRING THROUGH ROLLER CONNECTION
CUSTOM EXPOSED S.S. CONNECTION TO STRUCTURE BEYOND
WELD STEEL PLATE TO CUSTOM S.S. CONNECTION FOR CONNECTION TO STRUCTURE BEYOND
WELD STEEL PLATE TO END OF CUSTOM EXPOSED S.S. CONNECTION 1" TYP
3
WELD STEEL PLATE TO CUSTOM S.S. CONNECTION FOR CONNECTION TO STRUCTURE BEYOND CUSTOM NEOPRENE ROLLER, TYPICAL
DETAIL B AT S.S. CABLE CONNECTION
Gr
DETAIL A AT S.S. CONNECTION TO COVER PLATE
C PA
CABLE CLAMP CONNECTION, TYPICAL (SEE ELEVATIONS FOR CONNECTION POINTS)
tS
0.25” DIAMETER STEEL CABLE, STRING THROUGH ROLLER CONNECTION
ar
X
R25.00
CURTAINWALL AND MULLION SYSTEM, TYPICAL STEEL STRUCTURE AND CATWALK BEYOND
CUSTOM EXPOSED S.S. CONNECTION TO STRUCTURE BEYOND
86.05°
CABLE CLAMP CONNECTION, TYPICAL (SEE ELEVATIONS FOR CONNECTION POINTS) 0.25” DIAMETER STEEL CABLE, STRING THROUGH ROLLER CONNECTION
al Axonometric at Stainless Steel Connec on to Structure (SEE SYSTEMS DRAWINGS PART TWO) 4 Par 1" TYP NTS ROLLER
ROLLER
CABLE
CABLE
CUSTOM NEOPRENE ROLLER, TYPICAL
CRIMPED PIN CUSTOM ALUMINUM CABLE COVER, BOLT TO S.S. CONNECTION CUSTOM EXPOSED S.S. CABLE COVER CONNECTION, ANCHOR TO STRUCTURE BEYOND
6
Section Detail at Cable Pass-through Type C
4
NTS
Section Detail at Cable Pass-Through Type B
2
NTS
Axonmetric Detail at Typical Cable Pass-Through NTS
NEOPRENE SHIM WELD STEEL PLATE TO END OF CUSTOM EXPOSED S.S. CONNECTION
+32'-0" 3RD F.F.
0.25” DIAMETER STEEL CABLE, STRING THROUGH ROLLER CONNECTION
2" TYP.
CUSTOM EXPOSED S.S. CONNECTION TO STRUCTURE BEYOND
CUSTOM EXPOSED S.S. CONNECTION TO STRUCTURE BEYOND
CUSTOM EXPOSED S.S. CONNECTION TO STRUCTURE BEYOND
ROLLER
ROLLER
ROLLER
ROLLER
ROLLER
CABLE
CABLE
CABLE
CABLE
CABLE
7
CRIMPED PIN
OCCURS AT CONDITION TYPE C
2
CUSTOM EXPOSED S.S. CONNECTION TO STRUCTURE BEYOND
6.87°
CUSTOM EXPOSED S.S. CONNECTION TO STRUCTURE BEYOND
6.87°
CURTAINWALL AND MULLION SYSTEM, TYPICAL STEEL STRUCTURE AND CONCRETE POUR STOP, TYPICAL, BEYOND
0.75" TYP.
SPRINKLER SYSTEM BEHIND COVER PLATE
OCCURS AT CONDITION TYPE B
OCCURS AT CONDITION TYPE A, OR WHERE APPLICABLE
Sec on Detail at Exposed S.S. Connec on to Structure
1
3”=1’-0”
Exterior cladding rendering and details
OCCURS AT CONDITION TYPE A, OR WHERE APPLICABLE
OCCURS AT CONDITION TYPE A, OR WHERE APPLICABLE
Plan Details at Typical Cable Pass-Through Conditions NTS
Cable connection and aluminum cover diagrams and details 6
A1
Floor P