212
Exterior Floodlights
OLYMPIC
OLYMPIC
RADON
LAMPO
LAMPO
BARIO
STAR
RADON
Exterior Floodlights
PUNTO
LITIO
AGADIR
AGADIR
Punto Litio Agadir
p. 218 p. 219 p. 220
IRIDIO
IRIDIO
RODIO
RODIO
RODIO
Iridio Rodio
p. 222 p. 224
MINICESIO
CESIO
INDIO
INDIO
INDIO
Minicesio Cesio Indio
p. 228 p. 229 p. 230
CROMO
CROMO
CROMO
Cromo
p. 232
AREA
AREA
AREA
AREA
AREA
Olympic Lampo Area
p. 234 p. 238 p. 240
STAR
TEX
FORUM
FORUM
FORUM
Bario Star Tex Forum
p. p. p. p.
Radon
p. 256
Gallery
p. 258
Boro
p. 260
Sicura
p. 262
RADON
RADON
GALLERY
RADON
GALLERY
GALLERY
BORO
BORO
SICURA
SICURA
246 247 248 250
EXTERIOR FLOODLIGHTS
213
Exterior Floodlights
214
Rieti - Italy
Geneva Stadium - Switzerland
Czech Republic
Olympic City, Athens - (Greece)
Gomel - Belarus
Stadium - La Spezia
Beijin - China
Ski slope - Folgarida (Trento, Italy)
Ski slope - Zoetemer
Tripoli Stadium - Libya
Lachen Stadium - Switzerland
S. Moritz - Switzerland
Olimpic swimming pool - Hanoi (Vietnam)
Golf course - Shenzhen (China)
Palace of the ice - Belarus
Exterior Floodlights
Racecourse "Le Capannelle" - Roma (Italy)
Golf course Bouznika Bay - Casablanca (Marocco)
Stadium - Belgium
Bellinzona stadium - Switzerland
Ski slope - Bielmonte (Turin)
Golf Course Agele - China
Misano Adriatico Circuit - Rimini (Italy)
Shenzen - China
Kszo Stadium - Ostrowic (Polonia)
Slovakia
Champing - China
The Disano floodlights originate from a significant designing experience gained in every type of outdoor and indoor system. Ranging from large stadiums to indoor stadiums, from golf courses to swimming pools, these products can provide efficient solutions to all the complex problems encountered in these types of project. The Disano floodlights are able to comply with the demanding parameters required by the international competitions involving television broadcasts, and can blend perfectly also in the case of particular environmental situations, for example, on a ski slope. A complete range of powerful and reliable lighting fixtures for all the requirements of competitive and amateur sports activities.
EXTERIOR FLOODLIGHTS
Aleppo - Syria
215
Exterior Floodlights
216
Rome
Commercial Bank of Greece - Crete
Wilanow - Poland
Korea
Politeama Theater - Palermo (Italy)
Poland
Brodick Castle - Scotland
El Boulevard - Vitoria (Spain)
Poland
Administrative buildings on Masherov - Belarus
Castello Trakai - Lithuania
Valle dei Templi - Agrigento (Italy)
Arcakh - Armenia
Garny Pagan Temple - Armenia
Ursino Castle - Catania (Italy)
Exterior Floodlights
Branicki’s Palace, Bialystock - Poland
Terra Mitica - Benidorm - (Spain)
Switzerland
Bialystok - Poland
Assicurazioni “Metropolis” - Madrid (Spagna)
Palazzo Mezzanotte - Milan
Swimming Pool - Chang Wong - China
National bank of Belarus, Vitebsk branch
Republic Palace - Belarus
Stobhill Clock - Scotland
Gdansk - Poland
Today, outdoor lighting is an essential part of every town planning or architectural project that wishes to become a readily identifiable reference point. Monuments and other symbols of the history of a town/city, but also office buildings or public buildings with adequate outdoor lighting become an essential part of the night landscape. Disano floodlights are perfect instruments for these projects. The lighting fixtures are compact, powerful and reliable, ensure the desired lighting effect without any unpleasant interference with the architecture and the environments where they are installed.
EXTERIOR FLOODLIGHTS
217
Punto
218 300cm2
IP65IK08 F
ALO
1130 ALO 500
650 585 520 455 390 325 260 195 130 65
R7s beam angle cros. 2x22° len. 2x35°
270
90ϒ
EN EC
210
130
cd/klm
80ϒ 60ϒ 40ϒ 20ϒ 0ϒ 20ϒ 40ϒ 60ϒ 80ϒ
+
Rx7s 1131 - JM-TS 70
SAP-TS
angle cros. 2x22° 0ϒ len. 2x35° -20ϒ
cd/klm
cd/klm
60ϒ
Rx7s
40ϒ
20ϒbeam
EN EC
50 250
-60ϒ
500
360
-60ϒ-40ϒ-20ϒ 0ϒ 20ϒ 40ϒ 60ϒ
1130 Punto wattage
colour
MAX 500 MAX 500
s. silver black
CNRL wattage
colour
s. silver black s. silver black
JM-TS 70 JM-TS 70 SAP-TS 70 SAP-TS 70
weight
1131 Punto
3.50 3.50 3.50 3.50
S
weight
code
1.40 1.40
413613-00 413610-00
413746-00 413741-00 413747-00 413743-00
4000K - 5700lm - Ra 1b
178
Diffuser: tempered glass 5 mm thick, resistant to impact and thermal shock (UNI7142 tests, British standard 3193).
louvre 413603
black
125
ø7 2
800
Coating: black or sand-blasted silver-grey polyester powder coating, resistant to corrosive and saline environments.
Made of steel. To reduce glare effect and improve light control. For art. 1130-1131.
acc. 41
150
adjustable-angle arm 995503
Tropicalized steel painted by cationic electrocoating. For art. 1130-1131.
acc. 51 black
24 231
266
100
acc. 1133 black
Made of powder-coated steel. To direct the light beam. For art. 1130-1131.
180
143
acc. 333
173
graphite 164
ø10
140
shutter 413602
pole attach. ø60 997915
Made of aluminium. To be used to apply the fixture on a ø 60 pole.
40
ø 6, 5 40
Reflector: anodised, polished and hammered aluminium 99.85.
2000K - 6800lm - Ra 4
acc. 1134
179
160
210
Housing/frame: die-cast aluminium with cooling fins. Supplied with galvanized painted bracket.
Lamps (Ta=25°C) Kelvin - ølm - Ra
code
black 25
IP65IK08 F
100 25
-40ϒ
-80ϒ-60ϒ-40ϒ-20ϒ0ϒ 20ϒ 40ϒ 60ϒ 80ϒ
40
40
900 810 720 630 540 450 360 270 180 90
Made of steel. To reduce glare effects and improve light control. For art. 1149.
acc. 53 black
36 220
365
protection guard 995712
Plastic-coated steel rod. For protection against impact. For art. 1149.
acc. 43 black
20 185
188
baffle louvre 995711
baffle louvre 995709
Made of steel. To reduce glare effects and better direct the light beam. For art. 1148.
ø60
acc. 334
173
graphite
10
140 ø76
164
-
ø
JM-TS
600cm2
6,5
acc. 47
pole attach. ø76 997916
Made of aluminium. To be used to apply the fixture on a ø 76 pole.
black 36 180
285
protection guard 995710
Plastic-coated steel rod. For protection against impact. For art. 1148.
Litio EN EC
219 900cm2
SAP-TS
IP65IK08
Rx7s
ASYMM. 27°
1148 JM-TS 70
360
0ϒ
750
JM-TS
675 600
Rx7s
180ϒ
525 450 375 300 225 150
120
220
75 cd/klm
-120ϒ -90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
ø 14
70 70
UV
STOP
Housing/frame: die-cast aluminium with cooling fins.
LED
Diffuser: tempered glass 5 mm thick, resistant to impact and thermal shock (UNI7142 tests, British standard 3193). Coating: graphite grey or sand-blasted silver-grey polyester powder coating, resistant to corrosive and saline environments. Equipment: silicone rubber gasket. Fibreglass nylon cable gland Ø 1/2 ” gas. Steel bracket with protractor scale. The hinged front frame stays attached to the housing for easy maintenance.
CNRL
wattage
colour
weight
JM-TS 70 SAP-TS 70 JM-TS 70 SAP-TS 70
graphite graphite s. silver s. silver
4.90 4.80 4.90 4.80
Lamps (Ta=25°C) Kelvin - ølm - Ra
code
313340-00 313341-00 313336-00 313337-00
4000K - 5700lm - Ra 1b 2000K - 6800lm - Ra 4 4000K - 5700lm - Ra 1b 2000K - 6800lm - Ra 4 For lighting of vertical walls and areas that need to be kept completely glare free.
1200cm2
JM-E
IP65IK08
E27
ASYMM. 31°
1149 JM-TS 150
JM-TS
0ϒ
600
Fc2 SAP-TS
450
EN EC
1148 Litio - asymmetric
EXTERIOR FLOODLIGHTS
Reflector: asymmetric, 99.85 3µ thick anodised and polished hammered aluminium.
540 480
180ϒ
420
Rx7s
360
JM-TS
240
300 180
270
Rx7s
150
120 60 cd/klm
70 70
ø 14
-120ϒ -90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
UV
STOP
LED
1149 Litio - asymmetric CNRL
wattage
colour
JM-E 100 JM-TS 150 JM-TS 250 SAP-TS 150 JM-E 100 JM-TS 150 JM-TS 250 SAP-TS 150
graphite graphite graphite graphite s. silver s. silver s. silver s. silver
Lamps (Ta=25°C)
weight
code
Kelvin - ølm - Ra
6.90 7.20 8.45 7.80 6.90 7.20 8.45 7.80
313342-00 313343-00 313344-00 313352-00 313363-00 313364-00 313365-00 313366-00
3200K - 9000lm - Ra 2a 4200K - 12000lm - Ra 1b 4200K - 20000lm - Ra 1b 2000K - 15000lm - Ra 4 3200K - 9000lm - Ra 2a 4200K - 12000lm - Ra 1b 4200K - 20000lm - Ra 1b 2000K - 15000lm - Ra 4
Agadir
220
Housing/frame: Die-cast aluminium with cooling fins. Reflector: Asymmetric, 99.85 3µ thick anodised and polished hammered aluminium. Diffuser: Tempered glass 5 mm thick, resistant to impact and thermal shock (UNI7142 tests, British standard 3193). Coating: In several stages. First stage: grey epoxy-cationic electrocoating, resistant to corrosive and saline environments (it has passed the UNI ISO 9227 1000 hr test). Second stage: UV stabilising priming; final stage: rough finish with frosted silver acrylic paint. Wiring: 230V-50Hz power supply with heat protection. Flexible wire terminated with admiralty brass clamps; double insulation; cross-section: 1 sqmm. 2P terminal block (maximum allowed lead cross section 2.5 sqmm).
Pavia (Milan)
Agadir with 2 arms acc. 465 on pole
Agadir with arms acc. 464 on wall
acc. 464
280 663
80
70
Die cast aluminium supports with steel bracket. To wall mount art. 1563.
acc. 465
280 663
s. silver
1040
570 cm2
wall mount arm 991410
980
ø 11
57
130
25
s. silver
SAP-TS
pole mount arm 991411
Die cast aluminium supports with steel bracket. To pole mount both single and twin lamp version of art. 1563.
IP65IK08
Rx7s JM-TS
540
Rx7s 1596 JM-TS 150
225
ASYMM. 40°
UV
STOP
1563 Agadir - without louvre CNRL
wattage
colour
JM-TS 150 SAP-TS 150
s. silver s. silver
weight
code
9.70 9.70
411530-00 411531-00
Lamps (Ta=25°C) Kelvin - ølm - Ra
4200K - 12000lm - Ra 1b 2000K - 15000lm - Ra 4 To be used with arms acc. 464/465. On request: version with anti-glare louvre.
acc. 1492 h = 6500
pole ø 102 to be buried in the ground galvanized 425061
acc. 222
ø 102
s. silver
acc. 1494 h = 6500
galvanized
170
To be used to install acc. 464/465 with art. 1563 pole ø 102 with base 425071
To be used to install acc. 464/465 with art. 1563
ø 430
base pole Ø102 991399
Used as pole base cover acc. 1492/1494.
Agadir
221 570 cm2
JM-TS
IP65IK08
Rx7s SAP-TS
1
540
Rx7s
278 49
1584 JM-TS 150
ASYMM. 40°
275 49
UV
90ϒ
1584 Agadir - without louvre CNRL
wattage
colour
JM-TS 150 SAP-TS 150
s. silver s. silver
Lamps (Ta=25°C)
weight
code
Kelvin - ølm - Ra
9.90 9.90
421519-00 421520-00
4200K - 12000lm - Ra 1b 2000K - 15000lm - Ra 4
On request: version with anti-glare louvre.
570 cm2
JM-TS
IP65IK08
Rx7s SAP-TS 540
1
Rx7s
1589 JM-TS 150
180
225
ASYMM. 40°
ø 60
UV
STOP
1589 Agadir - with louvre + pole top Ø 60 CNRL
wattage
colour
JM-TS 150 SAP-TS 150
s. silver s. silver
Lamps (Ta=25°C)
weight
code
Kelvin - ølm - Ra
9.75 9.75
421569-00 421570-00
4200K - 12000lm - Ra 1b 2000K - 15000lm - Ra 4
This version includes an anti-glare louvre.
EXTERIOR FLOODLIGHTS
STOP
Iridio
222
Housing: Fibreglass reinforced plastic material.
SAP-TS Rx7s
Reflector: Symmetric or asymmetric, made of anodised, anodised and polished hammered aluminium 99.85.
JM-TS Rx7s
180ϒ
ASYMM. 40°
90ϒ
Diffuser: Tempered glass 5 mm thick , resistant to impact and thermal shock.
L’ENERGIA CHE TI ASCOLTA.
1200cm2
apert.fascio trasv.2x24 long.2x36
Wiring: 230V-50Hz power supply with heat protection. Wire terminated with admiralty brass clamps, silicone insulation with fibreglass braid; cross section: 1 sqmm. 2P terminal block (maximum allowed lead cross section 2,5 sqmm.)
SAP/JM-TS Rx7s
1720 JM-E 100
FLC-T/E Gx24-d4 JM/SAP-E
Equipment: Silicone rubber gasket. Fibreglass nylon cable gland, Ø 1/2” gas. Retained steel screws with special anticorrosion and anti-
E27
L’ENERGIA CHE TI ASCOLTA.
wattage
colour
JM-TS 70 JM-TS 70 SAP-TS 70 SAP-TS 70 JM-TS 150 JM-TS 150 SAP-TS 150 SAP-TS 150
black m. silver black m. silver black m. silver black m. silver
1719 - asymmetric
weight
code
5.10 5.10 5.10 5.10 5.80 5.80 5.90 5.90
411630-00 411640-00 411631-00 411641-00 411632-00 411642-00 411633-00 411643-00
EN EC
Lamps (Ta=25°C)
IP65IK08
Kelvin - ølm - Ra
4000K - 5700lm - Ra 1b 440
CNRL
2000K - 6800lm - Ra 4 4200K - 12000lm - Ra 1b
FLC 42 T/E JM-TS 70 JM-TS 70 SAP-TS 70 SAP-TS 70 JM-TS 150 JM-TS 150 SAP-TS 150 SAP-TS 150 JM-E 100 JM-E 100 SAP-E 70 SAP-E 70
black black m. silver black m. silver black m. silver black m. silver black m. silver black m. silver
weight
code
5.50 5.20 5.20 5.20 5.20 5.80 5.80 5.90 5.90 5.40 5.40 5.40 5.40
acc. 175 345
Lamps (Ta=25°C)
code
Kelvin - ølm - Ra
411736-00
4000K - 3200lm - Ra 1b
411730-00 411740-00 411731-00 411741-00 411732-00 411742-00 411733-00 411743-00 411734-00 411744-00 411735-00 411745-00
black 25
CELL
weight
14
EN EC
IP65IK08
4000K - 5700lm - Ra 1b 2000K - 6800lm - Ra 4 440
colour
4200K - 12000lm - Ra 1b 2000K - 15000lm - Ra 4 156
300
3200K - 9000lm - Ra 2a 70 70
2000K - 8500lm - Ra 4
Plastic-coated steel rod. For protection against impact. For art. 1719/1720.
14
acc. 176
protection guard 991370
black 20 256
250
206
500 ø60/ø76
baffle louvre 991371
Made of steel. To reduce glare and improve light control. For art. 1719/1720.
acc. 164
500
galvanized 280
wattage
1720 - symmetric
156
300
2000K - 15000lm - Ra 4
70 70
CNRL
408
1719 JM-TS 150
0ϒ
408
1200cm2
pole attachment 998097
Made in galvanized steel. To be used to apply on a pole until 4 fixture ø60/ø76.
Iridio
223
gripping treatment. Black painted steel bracket with protractor scale. The hinged front frame can be opened without tools, and stays attached to the housing for easy maintenance. Supplied with knife switch. Equipped with an air-circulation valve.
SAP-T
2200cm2
E40 1721 SAP-T 400
JM-T
0ϒ
E40 180ϒ
90ϒ
L’ENERGIA CHE TI ASCOLTA.
ASYMM. 23°
Supplied with knife switch.
SAP-T
2200cm2
E40 1722 JM-T 400
JM-T 500
E40
450 400 350 300
L’ENERGIA CHE TI ASCOLTA.
250
beam opening transv.2x25° long. 2x47°
150 100 50 cd/klm
-120ϒ -90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
EN EC
1721 - asymmetric
IP65IK08
CNRL
506
430
478
170
EN EC
180
colour
weight
code
SAP-T 250 SAP-T 250 SAP-T 400 SAP-T 400 JM-T 250 JM-T 250 JM-T 400 JM-T 400
black m. silver black m. silver black m. silver black m. silver
10.00 10.00 11.50 11.50 9.20 9.20 10.00 10.00
411831-00 411841-00 411832-00 411842-00 411833-00 411843-00 411834-00 411844-00
2000K - 48000lm - Ra 4 4500K - 20500lm - Ra 2b 4500K - 35000lm - Ra 2b
1722 - symmetric
CNRL
506
430
478
180
Lamps (Ta=25°C) Kelvin - ølm - Ra
wattage
colour
weight
code
SAP-T 250 SAP-T 250 SAP-T 400 SAP-T 400 JM-T 250 JM-T 250 JM-T 400 JM-T 400
black m. silver black m. silver black m. silver black m. silver
10.00 10.00 11.50 11.50 9.10 9.10 9.90 9.90
411931-00 411941-00 411932-00 411942-00 411933-00 411943-00 411934-00 411944-00
2000K - 28000lm - Ra 4 2000K - 48000lm - Ra 4 4500K - 20500lm - Ra 2b 4500K - 35000lm - Ra 2b
ø14
140 170
acc. 177 black
2000K - 28000lm - Ra 4
ø14
140 170
IP65IK08
170
Lamps (Ta=25°C) Kelvin - ølm - Ra
wattage
acc. 178
protection guard 991372
Plastic-coated steel rod. For protection against impact. For art. 1721/1722.
black 25
422 424
Adjustment protractor scale for accurate aiming of the floodlight. The front frame stays attached to the housing for easy maintenance.
baffle louvre 991373
Made of steel. To reduce glare and improve light control. For art. 1721/1722.
20 425
256
Anti-condensation system with exhaust valve enabling the air to circulate without altering the degree of protection and ensuring a longer service life of the components. Option to install a photocell.
EXTERIOR FLOODLIGHTS
200
Rodio
224
Bialystok - Santa Maria Assunta Cathedral (Poland)
Cruiser "Aurora" - St. Petersburg (Russia)
Housing: die-cast aluminium with cooling fins. Diffuser: tempered glass 5 mm thick, resistant to impact and thermal shock (UNI7142 tests, British standard 3193). Coating: graphite grey polyester powder coating, resistant to corrosive and saline environments. Electric gear: 230V/50HzHz power supply with heat protection. Flexible wire terminated with admiralty brass clamps, fibreglass braid insulation, cross section: 1sqmm.(up to 400W). 2P terminal block (maximum allowed lead cross-section: 4sqmm).
Anti-condensation system with exhaust valve ensuring air circulation without altering the degree of protection, for longer useful life of the components.
Equipment: silicone rubber gasket. Fibreglass nylon cable gland, Ø 1/2 gas. Ø 1/2inch gas. Corrosion and gripping resistant retained stainless steel screws. Steel bracket with protractor scale. The front frame opens on hinges (no tools required) and stays attached to the fixture housing. Equipped with air circulation valve. Latches: AISI 301 stainless steel. Supplied with knife switch in double insulation (without art. 1800).
"
The front frame stays attached to the housing for easy maintenance.
0ϒ
JM-TS
900cm2
EN EC
IP65IK08
Rx7s
180ϒ
SAP-TS
750
412
Rx7s 1800 JM-TS 70
ASYMM. 27°
368
UV
STOP
675 600 525
138
260
450 375
14
300
70
225 150
70
75 cd/klm
-120ϒ -90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
Reflector: asymmetric; made of 3µ thick 99.85 anodised and polished hammered aluminium.
For powerled version see LED chapter.
LED
1800 Rodio 1 - asymmetric CNRL
wattage
colour
JM-TS 70 SAP-TS 70
graphite graphite
code
Kelvin - ølm - Ra
5.50 5.50
414510-00 414511-00
4000K - 5700lm - Ra 1b 2000K - 6800lm - Ra 4
acc. 346 black 204 20
370
Lamps (Ta=25°C)
weight
acc. 349
louvre 997917
Made of steel. To reduce glare and improve light control. For art. 1800.
black 204 25
370
protection guard 997920
Plastic-coated steel rod. For protection against impact. For art. 1800.
Rodio EN EC
225 0ϒ
940cm2
SAP-TS
IP65IK08
Rx7s
180ϒ
1801 JM-TS 150
502
441
JM-TS Rx7s ASYMM. 35°
UV
STOP 303
161
70 70
14
EXTERIOR FLOODLIGHTS
Reflector: asymmetric; made of 3µ thick 99.85 anodised and polished hammered aluminium.
1801 Rodio 2 - asymmetric
CNRL wattage
colour
JM-TS 150 SAP-TS 150
graphite graphite
CNRL double insulation
Lamps (Ta=25°C)
weight
code
weight
code
Kelvin - ølm - Ra
7.35 7.35
414610-00 414611-00
7.35 7.35
414610-14 414611-14
4200K-12000lm - Ra 1b 2000K - 15000lm - Ra 4
Double insulation version supplied with knife switch.
EN EC
0ϒ
940cm2
SAP-TS
IP65IK08
Rx7s
180ϒ
1802 JM-TS 150
JM-TS
UV
450
502
441
Rx7s
STOP
405 360 315 270 225 180 135 90
303
45
161
cd/klm
-120ϒ -90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
70
70
14
Reflector: symmetric; made of 3µ thick 99.85 anodised and polished hammered aluminium.
1802 Rodio 2 - symmetric
CNRL wattage
colour
JM-TS 150 SAP-TS 150
graphite graphite
CNRL double insulation
Lamps (Ta=25°C)
weight
code
weight
code
Kelvin - ølm - Ra
7.35 7.35
414620-00 414621-00
7.35 7.35
414620-14 414621-14
4200K-12000lm - Ra 1b 2000K - 15000lm - Ra 4
Double insulation version supplied with knife switch.
acc. 350 black
acc. 347
protection guard 997921
Plastic-coated steel rod. For protection against impact. For art. 1801/1802.
black 247 25
442
louvre 997918
Made of steel. To reduce glare and improve light control. For art. 1801/2.
249 20
442
Rodio
226 0ϒ
SAP-T
1900cm2
135
55ϒ
315
45ϒ
E27
65ϒ
225
55ϒ
JM-T
105ϒ 95ϒ 85ϒ 75ϒ
45
65ϒ
115ϒ
461
105ϒ 95ϒ 85ϒ 75ϒ
514
1805 SAP-T 100
115ϒ
ne w
90ϒ
IP65IK08
E40
180ϒ
45ϒ
405
161
476
90
155 25 495 35ϒ 35ϒ cd/Klm 180 25ϒ 15ϒ 5ϒ 585 5ϒ 15ϒ 25ϒ270
70 70 170 170
Example of a streetlighting application
14
Reflector: light pollution preventing optic unit, pressed 99.85 aluminium, anodically oxidized and polished, supplied with light flux recovery device.
UV
STOP
1805 Rodio 3 - street optical CNRL
wattage
colour
weight
graphite 10.50 SAP-T 150 graphite 11.50 SAP-T 250 graphite 10.50 JM-T 150 Double insulation version supplied with knife
CNRL double insulation
code
weight
414720-00 414721-00 414722-00 switch.
10.50 11.50 10.50
Lamps (Ta=25°C) Kelvin - ølm - Ra
code
414720-14 414721-14 414722-14
2000K - 15000lm - Ra 4 2000K - 28000lm - Ra 4 4000K - 14000lm - Ra 1b
Version with street lighting fixture suitable for pole/head connection using acc. 333 or 334.
164
ø10
graphite
140
pole attach. ø60 997915
Made of aluminium. To be used to apply the fixture on a ø 60 pole.
500
galvanized
ø60/ø76
ø60
acc. 334
173
graphite 164
10
140
acc. 164
500 280
acc. 333
173
Made of aluminium. To be used to apply the fixture on a ø 76 pole.
Made in galvanized steel. To be used to apply on a pole until 4 fixture ø60/ø76.
acc. 351
pole attach. ø76 997916
black 419 25
461
pole attachment 998097
protection guard 997922
Plastic-coated steel rod. For protection against impact. For art. 1803/1804 double insulation
ø76
acc. 348 black 423 20
461
Made of steel. To reduce glare and improve light control. For art. 1803/4. Double insulation
acc. 404 black 410 20
453
acc. 403
louvre 997919
louvre 997924
Made of steel. To reduce glare and improve light control. For art. 1803/4.
black 403 25
456
protection guard 997923
Plastic-coated steel rod. For protection against impact. For art. 1803/4.
Rodio EN EC
227 0ϒ
1900cm2
SAP-T
IP65IK08
E40
180ϒ
1803 SAP-T 400
JM-T 500
522
455
E40
450 400
ASYMM 55°
350 300 250 200
EFF.= tot. 77% 461 70 70 170 170
150 100 50
145
cd/klm
-120ϒ -90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
14 UV
STOP
461
EXTERIOR FLOODLIGHTS
IP65IK08
514
EN EC
1803 Rodio 3 - asymmetric CNRL
wattage
476 70 70 170 170
161 14
Reflector: asymmetric 55° (efficiency 77%) made of 3µ thick 99.85 anodised and polished hammered aluminium.
EN EC
colour
weight
graphite 10.50 SAP-T 150 graphite 11.50 SAP-T 250 graphite 13.20 SAP-T 400 graphite 10.60 JM-T 250 graphite 11.30 JM-T 400 Double insulation version supplied with knife
code
414715-00 414716-00 414717-00 414718-00 414719-00 switch.
CNRL double insulation
weight
10.50 11.50 13.20 10.60 11.30
Kelvin - ølm - Ra
414710-14 414711-14 414712-14 414713-14 414714-14
2000K - 15000lm - Ra 4 2000K - 28000lm - Ra 4 2000K - 48000lm - Ra 4 4500K - 20500lm - Ra 2b 4500K - 35000lm - Ra 2b
0ϒ
1900cm2
SAP-T
IP65IK08
Lamps (Ta=25°C)
code
E40
180ϒ
1804 SAP-T 400
JM-T 455
522
500
E40
450 400
beam opening transv. 2x25° long. 2x47°
350 300 250 200 150 100 50
461 70 70 170 170
EN EC
145
cd/klm
-120ϒ -90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
14
IP65IK08
UV
514
461
STOP
1804 Rodio 3 - symmetric
CNRL 476 70 70 170 170
161 14
Reflector: symmetric made of 3µ thick 99.85 anodised and polished hammered aluminium.
wattage
colour
weight
code
graphite 10.50 414815-00 SAP-T 150 graphite 11.50 414816-00 SAP-T 250 graphite 13.20 414817-00 SAP-T 400 graphite 10.60 414818-00 JM-T 250 graphite 11.30 414819-00 JM-T 400 Double insulation version supplied with knife switch.
CNRL double insulation
weight
10.50 11.50 13.20 10.60 11.30
code
414810-14 414811-14 414812-14 414813-14 414814-14
Lamps (Ta=25°C) Kelvin - ølm - Ra
2000K - 15000lm - Ra 4 2000K - 28000lm - Ra 4 2000K - 48000lm - Ra 4 4200K - 20000lm - Ra 2b 4000K - 42000lm - Ra 2b
Mini Cesio
228
Housing/frame: die-cast aluminium with cooling fins.
Borromeo Palace - Milan
Diffuser: clear or frosted tempered glass, 5 mm thick, resistant to impact and thermal shock (UNI7142 tests, British standard 3193). Coating: sand-blasted silver-grey polyester powder coating, resistant to corrosive and saline environments. Electric gear: 230V-50Hz power supply with heat protection. Flexible wire terminated with admiralty brass clamps, silicone insulation with fibreglass braid; cross section: 1 sqmm 2P+T terminal block (maximum allowed lead cross-section: 4 sqmm). Equipment: silicone rubber gasket. Fibreglass nylon cable gland, Ø1/2 gas. Retained steel screws with special anticorrosion and anti-gripping treatment. Steel bracket with protractor scale. The hinged front frame stays attached to the housing for easy maintenance.
0ϒ
500cm2
SAP-TS
EN EC
IP66IK08
Rx7s
180ϒ
JM-TS
410
393
Rx7s 1199 JM-TS 150
ASYMM. 35°
145
300 70 70
14
Reflector: asymmetric made of 2µ thick 99.85 anodised and polished hammered aluminium.
UV
STOP
1199 Mini Cesio - asymmetric CNRL
wattage
JM-TS 70 SAP-TS 70 JM-TS 150 SAP-TS 150
colour
s. s. s. s.
silver silver silver silver
weight
6.30 6.00 7.00 7.30
411520-00 411521-00 411522-00 411523-00
acc. 143 black 20
248
212
Lamps (Ta=25°C)
code
Kelvin - ølm - Ra
4000K - 5700lm - Ra 1b 2000K - 6800lm - Ra 4 4200K - 12000lm - Ra 1b 2000K - 15000lm - Ra 4
acc. 141
baffle louvre 995733
Made of steel. To reduce glare and improve light control. Only for MiniCesio.
black 25 225
365
protection guard 995732
Plastic-coated steel rod. For protection against impact. Only for MiniCesio.
Cesio EN EC
229 SAP-TS
IP66IK08
0ϒ
1400cm2
Rx7s
180ϒ
1194 JM-TS 150
JM-TS Rx7s 475
545
Fc2 ASYMM. 40°
175
360 70 70
JM-TS
ø1
4
Reflector: asymmetric made of 2µ thick 99.85 anodised and polished hammered aluminium.
UV
EXTERIOIR FLOODLIGHTS
STOP
1194 Cesio - asymmetric
CNRL
EN EC
CNRL double insulation
Lamps (Ta=25°C)
wattage
colour
weight
code
weight
code
Kelvin - ølm - Ra
JM-TS 150 SAP-TS 150 JM-TS 250
s. silver s. silver s. silver
11.00 11.00 12.00
411220-00 411221-00 411222-00
11.00 11.00
411220-14 411221-14
4000K - 5700lm - Ra 1b 2000K - 15000lm - Ra 4 4200K - 20000lm - Ra 1b
JM-T
IP66IK08
0ϒ
1400cm2
G12
545 360 70 70
180ϒ
1198 JM-T 150
475
beam open. transv.2x2.5° long. 2x2.5°
175
ø1
4
Reflector: narrow beam high-gloss aluminium.
UV
STOP
1198 Cesio - narrow beam
CNRL
acc. 131 black
Lamps (Ta=25°C)
colour
weight
code
weight
code
Kelvin - ølm - Ra
JM-T 150
s. silver
10.20
411420-00
10.20
411420-14
4200K - 13000lm - Ra 1a
acc. 132
protection guard 995730
Plastic-coated steel rod. For protection against impact. Only for Cesio.
CNRL double insulation
wattage
black 35 280
420
baffle louvre 995731
Made of steel. To reduce glare effects and improve light control. Only for Cesio.
25 305
320
Indio
230
Housing/frame: Die-cast aluminium with cooling fins. Reflector: Symmetric or asymmetric, made of 3µ thick anodised and polished hammered aluminium 99.85. Diffuser: Tempered glass 5 mm thick, resistant to impact and thermal shock (UNI7142 tests, British standard 3193). Coating: Graphite grey polyester powder coating, resistant to corrosive and saline environments. Electric gear: 230V-50Hz power supply with heat protection. Flexible wire terminated with admiralty brass clamps, fibreglass braid insulation, cross-section: 1 sq mm (up to 400W) or 2.5 sq mm (400 to 1500W). 2P+T terminal block (maximum allowed lead cross section 4 sqmm.) Equipment: Silicone rubber gasket. Fibreglass nylon cable gland, Ø 1/2 gas. Retained steel screws with special anticorrosion and anti-gripping treatment. Steel bracket with protractor scale. The hinged front frame stays attached to the housing for easy maintenance.
Example of bracket installation, acc. 164, using up to 4 floodlights.
acc. 164
500 280
galvanized
500 ø60/ø76
Made in galvanized steel. To be used to apply on a pole until 4 fixture ø60/ø76.
acc. 71 black
30
0ϒ
acc. 73
baffle louvre 995715
black
Made of steel. To reduce glare and improve light control.
391
407
pole attachment 998097
1900cm2
25 390
420
ALO
Plastic-coated steel rod. For protection against impact.
EN EC
IP66IK08
R7s
1157 - ALO 1000 400 360 320 280 240 200 160 120 80 40
+ -
60ϒ
20ϒ 0ϒ
-20ϒ -40ϒ -60ϒ
-80ϒ-60ϒ-40ϒ-20ϒ0ϒ 20ϒ 40ϒ 60ϒ 80ϒ
cd/klm
10 50
40ϒ
cd/klm
60ϒ
cd/klm
100 25
70 70 170 170
-60ϒ-40ϒ-20ϒ 0ϒ 20ϒ 40ϒ 60ϒ
10 50
20ϒ 0ϒ
-20ϒ -40ϒ -60ϒ
-80ϒ-60ϒ-40ϒ-20ϒ0ϒ 20ϒ 40ϒ 60ϒ 80ϒ
cd/klm
147
461 250
40ϒ
LED
484
beam opening transv. 2x49° long. 2x49° 532
ne w
180ϒ
400 360 320 280 240 200 160 120 80 40
protection guard 995716
250 100 25
-60ϒ-40ϒ-20ϒ 0ϒ 20ϒ 40ϒ 60ϒ
LED mutanti versions: see chapter LED and mutanti.
1157 Indio wattage
colour
weight
ALO 1000
graphite
7.60
S code
413816-00
ø14
Indio EN EC
231 0ϒ
1900cm2
JM-T
IP66IK08
E40
180ϒ
1158 JM-T 400
SAP-T 500
484
400 350
ne w
532
450
E40
300 250 200 150 100 50
147
461
cd/klm
-120ϒ -90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
70 70 170 170
ø14
+ -
Reflector: Symmetric or asymmetric, made of 3µ thick anodised and polished hammered aluminium 99.85.
UV
EXTERIOR FLOODLIGHTS
STOP
1158 Indio - symmetric CNRL
Lamps (Ta=25°C)
wattage
colour
weight
code
Kelvin - ølm - Ra
SAP-T 150 SAP-T 250 SAP-T 400 JM-T 250 JM-T 400 JM-T 250 FS JM-T 400 FS
graphite graphite graphite graphite graphite graphite graphite
10.40 11.70 13.10 10.60 11.70 10.80 11.70
414062-00 414063-00 414064-00 414065-00 414066-00 414067-00 414068-00
2000K - 15000lm - Ra 4 2000K - 28000lm - Ra 4 200 K - 48000lm - Ra 4 4500K - 20500lm - Ra 2b 4500K - 35000lm - Ra 2b 4500K - 20500lm - Ra 2b 4500K - 35000lm - Ra 2b
F.S.: narrow beam.
EN EC
0ϒ
1900cm2
JM-T
IP66IK08
E40
180ϒ
1159 SAP-T 400
SAP-T 500
484
532
450
E40 ASYMM. = 55° EFF.= 77%
400 350 300
ne w
250 150 100 50
147
461
200
cd/klm
-90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ150ϒ
70 70 170 170
ø14
+ -
Reflector: asymmetric 55° (efficiency 77%) made of 3µ thick 99.85 anodised and polished hammered aluminium.
H
UV
STOP L
1159 Indio - asymmetric CNRL
Lamps (Ta=25°C)
wattage
colour
weight
code
Kelvin - ølm - Ra
SAP-T 150 SAP-T 250 SAP-T 400 JM-T 250 JM-T 400
graphite graphite graphite graphite graphite
10.40 11.70 13.10 10.60 11.70
414162-00 414163-00 414164-00 414165-00 414166-00
2000K - 15000lm - Ra 4 2000K - 28000lm - Ra 4 2000K - 48000lm - Ra 4 4500K - 20500lm - Ra 2b 4500K - 35000lm - Ra 2b
For lighting vertical walls and areas that require good glare control.
Cromo
232
Housing/frame: Die-cast aluminium with cooling fins.
Breclav Castle -Czech Republic
Diffuser: Tempered glass 5 mm thick, resistant to impact and thermal shock (UNI7142 tests, British standard 3193). Coating: Graphite grey polyester powder coating, resistant to corrosive and saline environments. Electric gear: 230V-50Hz power supply with heat protection. Flexible wire terminated with admiralty brass clamps, fibreglass braid insulation, cross-section: 1 sq mm (up to 400W) or 2.5 sq mm (400 to 1000W). 2P or 2P+T terminal block (maximum allowed lead cross-section 4 sqmm.) Equipment: Silicone rubber gasket . Fibreglass nylon cable gland, Ø1/2 gas. Retained steel screws with special anticorrosion and antigripping treatment. Steel bracket with protractor scale. The hinged front frame stays attached to the housing for easy maintenance. The double insulation version is supplied with a separate gear box attached to the bracket.
0ϒ
2400cm2
JM-T
EN EC
IP65IK08
E40
180ϒ
472
SAP-T E40
+
ASYMM. 50°
558
1129 JM-TS 400
197
497
190
140 190
ø 14
UV
STOP
Reflector: asymmetric, 99.85 3µ thick anodised and polished hammered aluminium.
1129 Cromo - asymmetric wattage
colour
weight
SAP-T 250 SAP-T 400 JM-T 250 JM-T 400
graphite graphite graphite graphite
16.10 17.50 15.20 16.00
CNRL
code
weight
code
412947-00 412948-00 412949-00 412950-00
16.10 17.50 15.20 16.00
412947-14 412948-14 412949-14 412950-14
acc. 21 black 30 424
441
CNRL double insulation
CNRL with switching device
weight
16.10 17.50 15.20 16.00
Kelvin - ølm - Ra
412947-79 412948-79 412949-79 412950-79
2000K - 28000lm - Ra 4 2000K - 48000lm - Ra 4 4500K - 20500lm - Ra 2b 450 K - 35000lm - Ra 2b
acc. 23
baffle louvre 995721
Made of steel. To reduce glare and improve light control.
Lamps (Ta=25°C)
code
black 36 425
439
protection guard 995722
Plastic-coated steel rod. For protection against impact.
Cromo EN EC
233 0ϒ
2400cm2
JM-T
IP65IK08
E40
472
180ϒ
1129 JM-T 1000
ASYMM. 35°
500 450 400
558
350 300 250 200 150 100
197
497
+
50 cd/klm
140 190 190
-120ϒ -90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
ø 14
UV
STOP
EXTERIOR FLOODLIGHTS
Reflector: asymmetric, 99.85 3µ thick anodised and polished hammered aluminium.
1129 Cromo - asymmetric S+L
wattage
colour
weight
JM-T 1000
graphite
12.50
JM-T 1000
black
Lamps (Ta=25°C) Kelvin - ølm - Ra
code
412951-00
4400K - 90000lm - Ra 1b To be used with acc. 1177 control gear box. If the box is placed at a distance of over 3 meters from the fixture. to buy acc. 1178 cod 997650
acc. 1177
gear CC - IP657 13.60 997643-00
Die-cast aluminium box, painted black by epoxy cationic electrocoating colour black. Recommended installation at a maximum distance of 3 meters from the fixture. Contents: ballast, igniter and capacitor.
0ϒ
2600cm2
JM-T
IP65IK08
E40 472 472
155
180ϒ
1129 JM-T 1000
SAP-T 650
E40
585 520
558 558
ASIMM. 35°
455
+
390 325
-
260 195 130
197 197
497 497 140 140 190 190 190 190
65 cd/klm
-120ϒ -90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
øø 14 14
UV
STOP
Reflector: asymmetric, 99.85 3µ thick anodised and polished hammered aluminium.
1129 Cromo - double insulation CNRL
acc. 59 galvanised
colour
weight
code
Kelvin - ølm - Ra
SAP-T 600 JM-T 1000
graphite graphite
20.00 20.00
412924-00 412925-00
4400K - 90000lm - Ra 1b 2000K - 90000lm - Ra 4
acc. 60
pole bracket 997900
Bracket for pole mounting 1 or 2 end-to-end floodlights. For Ø 60/76 mm poles.
Lamps (Ta=25°C)
wattage
450 275 90
galvanised
pole bracket 997901
Bracket for pole mounting 2 or 4 end-to-end exterior floodlights. For Ø 60/76 mm poles.
1100
275 90
Olympic
234
Housing: In die-cast aluminium EN AB 46100. Cover: in die-cast aluminium EN AB 46100 with cooling fins. Lamp housing rear access. Hinge opening with stainless steel latches. Reflector: asymmetric, in polished aluminium 99.85, anodically oxidized and polished, the luminous flux can be adjusted to obtain 4 different photometric distributions. Diffuser: tempered glass, 4 mm thick, resistant to thermal shock and impact (UNI EN 12150-1:2001 tests). 20° tilt angle glass to obtain high-asymmetry louvre efficiency and maximum luminous intensity. Coating: polyester resin powder paint, resistant to corrosion and saline environments. Lamp holder: can be adjusted in 4 different positions to change photometric distribution in relation to the position of the installation. Electric gear: 230V/50Hz power supply (1000W) or 400V (2000W) wire terminated with admiralty brass clamps, silicone insulation with fibreglass braid, cross-section 2.5 sq mm. 2P+T terminal block, maximum allowed lead cross section 6 sq mm. Standard supply: tool-free maintenance operations. Disconnecting switch supplied to interrupt the line during maintenance. Equipment: silicone rubber gasket. ½ gas nylon cable gland. Galvanized steel bracket coated with goniometric scale. Stainless steel external screws. Air recycling valve.
Requirements: sports lighting systems: • excellent horizontal and vertical lighting • even light distribution • vertical lighting camera setting • chromatic performance • reduced light pollution/dazzling This is due to higher game levels and increased speed; as a result, improved light quality and luminaires are required. 100
JM-TS 2000 LA
Duration %
90 80
Table of lamp characteristics LA 2000w LA 2000w 400V/842 400V/956 P 2040 2040 Flux lm 220.000 190.000 T colour (k°) 4200 5600 Ra 80 90
LA 1000w 230V/842 1040 100.000 4200 80
JM-TS 2000 SA
70
60 50 1000
2000
3000
4000
5000
Duration average life
Light pollution
CUT-OFF Ligth reaches the buildings
Spectators are dazzled
Light on the work surfaces
Less dispersion of light
LA 1000w HQI-TS2000w 230V/956 400V/841 1040 2180 90.000 225.000 5600 4100 90 60-69
Olympic
235
Project example CHARACTERISTICS Pole height
Range
LIGHTING RESULTS
Lamp W
Quantity
E average lux
E minimum E average
Coef. used
4 pole 20m 105x65
JM-TS/LA 2000W
24
304
0,73
0,50
4 pole 20m 105x65
JM-TS/LA 2000W
12
168
0,72
0,54
4 pole 16m 100x60
JM-TS/LA 2000W
20
310
0,75
0,51
4 pole 16m 100x60
JM-TS/LA 2000W
12
205
0,60
0,57
4 pole 25m 105x65
JM-TS/LA 2000W
28
317
0,74
0,50
TILTED GLASS 90% maximum light intensity
glass refraction 10%
As opposed to traditional solutions, this is achieved by tilting the reflector’s glass cover by 20° in relation to the horizontal worktop, thus creating a front screen that protects the upward light flux.
20°
90°
The development of optic units for sports facilities has improved the efficiency of the luminaires in order to guarantee increasingly efficient lighting performance.
°
65
Glass inclination reduces the negative effect of the incidence angle of rays of light on the glass, improving photometric distribution and floodlight efficiency. Olympic is the floodlight designed for perfect horizontal installation (cut-off), whilst providing excellent even light distribution in the lit area, in compliance with nonpolluting requirements.
GLASS FLAT 70% maximum light intensity
°
glass refraction 30%
90
The designer has 4 different light beams to use for the floodlight lamp, which can be adjusted in 4 different positions to meet different planning requirements. The 4 different light beams available, including the widest and the narrowest one, in combination with a highly asymmetric tilt angle, boost light efficiency in the area to illuminate, guaranteeing good even light distribution and reducing the amount of light dispersed outside the area concerned, as well as intrusive and dazzling light in the surrounding areas.
°
65
The different positions of the lamp are designed to obtain different asymmetric angles without tilting the floodlights.
The flexibility of the Olympic lamp makes the luminaire particularly suitable for indoor and outdoor system planning, providing good visual comfort to players and spectators alike. The optical system comes with a lamp holder that can be adjusted in 4 different positions, lending itself to different photometric curves according to the type of installation chosen. Position 2
Position 1 3
1900
3
1710
2 1
1330 1140
4
950
2 1
1085 930 775
760
620
570
465 310
380 190
155
cd/klm
cd/klm
-120ϒ -90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
-120ϒ -90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
Position 4
Position 3 3
1250
3
1125 1000
4
1395 1240
1520
4
1550
2 1
875 750 625
1395 1305 1160
4
2 1
1015 870 725
500
580
375
435
250
290
125
145
cd/klm
cd/klm
-120ϒ -90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
-120ϒ -90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
EXTERIOR FLOODLIGHTS
Optics group development
Olympic
236
Bracket with goniometric scale and locking pin designed to avoid altering the aiming system. Accurate aiming visor. Stainless steel latch. The lamp housing opens on hinges and stays hooked to the housing. Supplied with f.g. nylon switch box
black 417
Plastic-coated steel rod. For protection against impact. To install with acc. 112.
acc. 479
160
black 705
protection guard 995780
conveyor 995781
Made of steel. To convey the beam in one direction. To install with acc. 478.
600
428
acc. 480 black
louvre 995782
Made of steel. To reduce glare and improve light control. 590 62
acc. 1177 gear CC IP65 JM-TS/ 997640-00 SAP-T 1000 JM-TS 2000 997642-00 Aluminium box with removable steel gear tray. Contents: ballast and capacitor.
acc. 163
650
galvanized 355
acc. 478 580
650
steel pole mount 998094
To be used to install up to 4 Olympic floodlights on steel poles.
ø 140
Short arc lamps SA JM-TS1000/230V 986113 JM-TS2000/400V 986118 When ordering specify the type and the colour of the lamps. 986113: 4400 K-90000 lm-90 lm/W-Ra 1B 986118: 5900 K-200000 lm-100 lm/W-Ra 1A
Long arc lamps LA JM-TS 1000/230V 986121 JM-TS 2000/400V 986122 JM-TS 2000/400V 986122-49 When ordering specify the type and the colour of the lamps. 986121 - 5600K (for TV filming) Ra 90 986122 - 5600K (for TV filming) Ra 90 986122-49 - 4400K - 2B - Ra 85
Olympic IP65IK08
237 L=1400cm2 F=2300cm 2
JM-TS...LA
F
754
a cavo SAP-T
JM-T
E40
E40
ASYMMETRIC VARIABLE: 55°-60°-65°
0ϒ 180ϒ
662
300
417 140 280 380
ø21
+
EXTERIOR FLOODLIGHTS
-
1808 Olympic - asymmetric for Lamps LA wattage
colour
weight
S
code
weight
S+L
code
weight
CNR hot start
Lamps (Ta=25°C) Kelvin - ølm - Ra
code
Max-TS 1000LA silv.+grap. 17.85 415210-00 20.85 415210-99 Max-TS 2000LA silv.+grap. 17.85 415211-00 20.85 415211-99 SAP-T 1000 silv.+grap. 17.55 415212-00 JM-T 1000 silv.+grap. 17.55 415213-00 Please note: floodlight sub-code –49 should be ordered when using lamp sub-code –49. Without electric gear (see acc. 1177).
IP65IK08
2000K - 130000lm - Ra 4 4400K - 90000lm - Ra 1b
L=1400cm2 F=2300cm 2
JM-TS...SA
F
754
short arc
300
0ϒ
ASYMMETRIC VARIABLE: 55°-60°-65°
662
180ϒ
417 140 280 380
ø21
+ -
1809 Olympic - asymmetric for Lamps SA wattage
colour
weight
Max-TS 1000SA silv.+grap. 17.85 Max-TS 2000SA silv.+grap. 17.85 Without electric gear (see acc. 1177).
S
code
weight
415220-00 415221-00
20.85 20.85
CNR hot start
code
415220-99 415221-99
Lampo
238
Housing/frame: EN AB 46-100 diecast aluminium, with wide cooling fins.
Dinamo Vitebsk stadium - Belarus
Diffuser: Tempered glass 5 mm thick, resistant to impact and thermal shock (UNI7142 tests, British standard 3193). Coating: Graphite grey polyester powder coating, resistant to corrosion and saline environments. Electric gear: Power supply for 400V lamp. Flexible wire terminated with admiralty brass clamps, insulation with fibreglass braid; cross section: 2.5 sqmm . 2P+T terminal block (maximum allowed lead cross-section: 4 sqmm).
ma
x4
5Ď’
Standard supply: The back of the fixture opens on hinges. Equipped with an air-circulation valve.
The lamp housing opens on hinges. When open, the lamp housing stays attached to the luminaire body for easy maintenance, while aiming remains unchanged.
Equipment: Silicone rubber gasket . Fibreglass nylon cable gland, Ă˜1/2 gas. Retained steel screws with special anticorrosion and anti-gripping treatment. Steel bracket with protractor scale. Igniter box thermally isolated from the housing.
Installation position
Lamps for art. 1125 JM-T2000D/I With built-in igniter.
37 black 180 320
240
986110
7250K - 180000lm- IRC93 - 400 V.
acc. 19
box - IP65 997601
black
Aluminium box with steel gear tray. Cationic electrocoating. Fitted to contain electric accessories.
acc. 1177 gear CC IP65 JM-T 2000 997642-00 Made of aluminium with removable steel gear tray. Contents: ballast and capacitor.
Standard supply includes connection box with the option to insert the igniter when using lamps not equipped with built-in igniter. Option to move the light recovery fin in the reflector, to optimize the luminous efficiency and to direct the light when the floodlight is installed with the bracket upwards.
600
520
protective guard 995700
Plastic-coated steel rod. For protection against impact.
acc. 20 black 100 645
565
baffle louvre 995699
Steel painted by cationic electrocoating. To reduce glare and improve light control.
Bracket with adjustment protractor scale for accurate aiming of the floodlight. Supplied with fixing pin to prevent aiming variations.
Lampo EN EC
239 JM-T
IP65IK08
0ϒ
3900cm2
E40
610
305
180ϒ
beam opening transv.3,5+4,5° long.35°+38°
785
638
1125 - JM-T 2000 FS
140 140 560
ø 20
+ EXTERIOR FLOODLIGHTS
Reflector: Pressed prismatic aluminium 99.85, anodised and polished, with light narrow beam recovering fin.
1125 Lampo - narrow beam S
wattage
colour
weight
code
JM-T 2000
graphite
21.50
412644-00
Supplied without igniter. To be used with acc. 1177.
EN EC
JM-T
IP65IK08
0ϒ
3900cm2
E40
610
180ϒ
beam opening transv.12°+16° long.35°+40°
305
140 140 560
638
785
1125 - JM-T 2000 FL
ø 20
+ -
Reflector: Pressed prismatic aluminium 99.85, anodised and polished, with light wide beam recovering fin.
1125 Lampo - wide beam S
wattage
colour
weight
code
JM-T 2000
graphite
21.50
412645-00
Supplied without igniter. To be used with acc. 1177.
Area
240
ADVICE/RECOMMENDATIONS FOR SELECTING LIGHT SOURCES UNI 12193 definition of the level of vertical illuminance, according to the sport (A,B,C) and the distance (from 400 to 1400lx) - colour temperature 4000ke 6500k - colour rendering Ra>65, preferably at least 80
FIFA recommendations UEFA recommendations lighting concept designed with TV transmissions -classification according to the match: in mind: classes IV and V (national matches, suitability of the ground for hosting the match. national and international TV transmissions)
IV IV(TV) V E Hor. 500lx 1000-2000lx 1500-3000lx E vert. 1000lx 1000-1800lx T col. 4000k >4000k >5500k Ra 80 >80 >80 (pref.90) Conclusions - UNI standards do not specifically deal with the issues of TV transmissions - when TV transmissions are taken into account, the levels of vertical illuminance increase enormously - when the level of vertical illuminance is >1000lx Tc >4000k, Ra >80 are always recommended - the minimum Ra level is 65, but in any situation where there is >500 lux the prefe-
Steel bracket with protractor scale, supplied with fixing pin to prevent aiming variations. Aiming visor for perfect aiming. Stainless steel latch. Hinged opening of the lamp compartment which remains attached to the housing when open. Fibreglass nylon box for ignitor.
E Hor. E vert. T col. Ra
800-1400lx 4000-6000k >65 (pref.90)
rable level is at least 80 - the choice of the kind of source (long, short arc) it must be made weighing the need for light control against running costs - LA long arc lamps permit selection of the colour temperature regardless of the characteristics of the fixture - LA long arc lamps offer better results in terms of purchase and running costs, with a minimum colour rendering of 80
Area
241
EXTERIOR FLOODLIGHTS
Palaoval - Turin
The support bracket can be rotated 360째 permitting the light to aimed in the right direction when the floodlight is installed with the bracket above
JM-TS 2000 LA Duration %
JM-TS 2000 SA
Acc. 345 JM-TS 2000 AC Duration average
Table of lamp characteristics LA 2000w LA 2000w 400V/842 400V/956 P 2040 2040 FLux lm 220.000 190.000 T colour (k째) 4200 5600 Ra 80 90
LA 1000w 230V/842 1040 100.000 4200 80
LA 1000w HQI-TS2000w 230V/956 400V/841 1040 2180 90.000 225.000 5600 4100 90 60-69
Light pollution
CUT-OFF Light reaches the buildings
Spectators are dazzled
Light on the work surface
Less dispersion of light
Area
242
Housing/frame: die-cast aluminium (ENAB 46-100) with cooling fins.
Tel Aviv stadium
Diffuser: 5 mm tempered glass, resistant to impact and thermal shock (UNI 12150-1: 2001 tests). Coating: with silver or graphite grey polyester powder, resistant to corrosive and saline environments. Electric gear: power supply 400V (2000W) e 230V (1000W). Wire terminated with admiralty brass clamps, silicone insulation with fibreglass braid, cross-section: 2.5 sqmm 2P+T nylon terminal block (maximum allowed lead cross-section: 6 sqmm). Standard features: it is possible to perform maintenance without using tools through the hinged opening at the rear of the fixture. Equipped with an air-circulation valve. Equipment: fibreglass nylon cable gland, Ø 1/2” gas. Supplied with knife switch enabling safe lamp replacement. Steel bracket with protractor scale and aiming visor. Retained steel screws with special anticorrosion and anti-gripping treatment. Igniter box thermally isolated from the housing. With gasket made of silicone-coated material.
3000cm2
JM-TS...LA
EN EC
IP66IK08
F
a cavo 650
0ϒ
540
1744 - JM-TS 2000 FM cd/klm
538
180ϒ
333
1665 1480 1295 1110
403
925
140 280 380 540
740 555 370
+
185 0 -120ϒ-90ϒ -60ϒ -30ϒ 0ϒ
ø 21
30ϒ 60ϒ 90ϒ 120ϒ
-
Reflector: narrow beam polished 99.85 aluminium, anodised and polished, with light beam recovering fin.
1743 Area - narrow beam wattage
colour
weight
Max-TS 1000LA Max-TS 2000LA
silver+graphite silver+graphite
23.00 23.00
S
code
weight
415010-00 415011-00
42.90 42.90
CNR hot start code
weight
415010-99 415011-99
42.90
S for lamp sub-code -49 code
415011-49
To be used with acc 1177. With standard igniter located inside the special nylon box. For long arc lamps (choose type and colour temperature). Hot start version supplied with acc. 1177 (17,60 kg). Other versions: please note if order lamp with subcode -49, order EXTERIOR FLOODLIGHTS with subcode -49. The floodlight with subcode-49 is not suitable for hot start.
Area EN EC
IP66IK08
243
650
a cavo
333
180ϒ
1744 - JM-TS 2000 FM
538
540
0ϒ
3000cm2
JM-TS...LA
F
810 720 630
403 140 280 380 540
540 450
ø 21
360 270 180 90
+
cd/klm
-120ϒ-90ϒ -60ϒ -30ϒ 0ϒ
30ϒ 60ϒ 90ϒ 120ϒ
EXTERIOR FLOODLIGHTS
Reflector: medium beam polished 99.85 aluminium, anodised and polished, with light beam recovering fin.
1744 Area - medium beam wattage
colour
weight
Max-TS 1000LA Max-TS 2000LA
silver+graphite silver+graphite
23.00 23.00
S
code
weight
415020-00 415021-00
42.90 42.90
CNR hot start
S for lamp sub-code -49
code
weight
code
415020-99 415021-99
42.90
415021-49
To be used with acc 1177. With standard igniter located inside the special nylon box. For long arc lamps (choose type and colour temperature). Hot start version supplied with acc. 1177 (17,60 kg). Other versions: please note if order lamp with subcode -49, order EXTERIOR FLOODLIGHTS with subcode -49. The floodlight with subcode-49 is not suitable for hot start.
EN EC
IP66IK08
0ϒ
3000cm2
JM-TS...LA
F
a cavo 650
180ϒ
1745 - JM-TS 2000 FL
538
540
333
750 675 600 525
403-
450 375
140 280 380 540
300
ø 21
225 150 75
+
cd/klm
-120ϒ-90ϒ -60ϒ -30ϒ 0ϒ
30ϒ 60ϒ 90ϒ 120ϒ
-
Reflector: wide beam polished 99.85 aluminium, anodised and polished, with light beam recovering fin.
1745 Area - wide beam wattage
colour
weight
Max-TS 1000LA Max-TS 2000LA
silver+graphite silver+graphite
23.00 23.00
S
code
weight
415030-00 415031-00
42.90 42.90
CNR hot start
S for lamp sub-code -49
code
weight
code
415030-99 415031-99
42.90
415031-49
To be used with acc 1177. With standard igniter located inside the special nylon box. For long arc lamps (choose type and colour temperature). Hot start version supplied with acc. 1177 (17,60 kg). Other versions: please note if order lamp with subcode -49, order EXTERIOR FLOODLIGHTS with subcode -49. The floodlight with subcode-49 is not suitable forhot start.
Area
244
SWIMMING POOL
PROJECT
Dimensions 51,6 x 26,6 m Liable to be approved by CONI for competitions with large audience and for professional contests with colour televising. Floodlights: art. 1746 Area Asymmetric reflector JM-TS 1000W Light flux 72.000 lm Total power 80.000 kW Height 13 m Total floodlight no. 80 Initial average illuminance
TV position average
horiz. vert. north vert. observant Average horizontal
1883 lux 1099 lux 1320 lux 1883 lux
Overall vertical uniformity Ug = 0,70 Medium average vert. north 1099 lux gen. uniformity Ug = 0,45 Medium average vert. observant 1320 lux Overall vertical uniformity Ug = 0,54
acc. 316
525
inox 448
protection guard 995765
Made from steel rods. For protection against impact.
598
acc. 317
300
black
conveyor 995766
Made of steel. Used to direct the light beam in one direction.
521 72
black
Made of steel. To reduce glare and improve light control. 75
acc. 345 60 60
340
acc. 319
baffle louvre 995767
598
asymmetric shield. 995768
Made of steel. To reduce glare and and improve light control for asymmetric Area floodlights.
75
tilted bracket 995770
To be used to install Area on platforms with glass parallel to the ground.
black
448
acc. 163
650
galvanized 355
acc. 318 449
598
650
steel pole mount 998094
To be used to install up to 4 Area floodlights on steel poles
ø 140
acc. 1177 gear CC IP65 JM-TS/ 997640-00 SAP-T 1000 JM-TS 2000 997642-00 Aluminium box containing ballast, igniter and capacitor.
Long arc lamps LA JM-TS 1000/230V 986121 JM-TS 2000/400V 986122 JM-TS 2000/400V 986122-49 When ordering specify the type and the colour of the lamps: 986121 - 5600K (for TV filming) Ra 90 986122 - 5600K (for TV filming) Ra 90 986123 - 4200K - Ra 90
Area EN EC
IP66IK08
245 0ϒ
3000cm2
JM-TS...LA
F
a cavo 650
180ϒ
SAP-T
333
538
540
E40 1746 - JM-TS 2000W
ASIM. 60°
750 675 600 525 450
403140 280 380 540
375 300
ø 21
225 150 75
+
cd/klm
-90ϒ -60ϒ -30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ 150
EXTERIOR FLOODLIGHTS
Reflector: asymmetric and symmetric polished 99.85 aluminium, anodised and polished, with light beam recovering fin. The asymmetric version emits a 60° light flux.
1746 Area - asymmetric 60° wattage
colour
weight
S
code
weight
S+L
code
weight
CNR hot start
Lamps (Ta=25°C) Kelvin - ølm - Ra
code
Max-TS 1000LA silver+graphite 23.00 415110-00 23.00 415110-99 Max-TS 2000LA silver+graphite 23.00 415111-00 23.00 415111-99 SAP-T 1000 silver+graphite 23.00 415120-00 2000K - 130000lm - Ra 4 To be used with acc 1177. With standard igniter located inside the special nylon box. For long arc lamps (choose type and colour temperature). Hot start version supplied with acc. 1177 (17,60 kg). Other versions: please note if order lamp with subcode -49, order EXTERIOR FLOODLIGHTS with subcode -49. The floodlight with subcode-49 is not suitable for hot start.
EN EC
IP66IK08
0ϒ
3000cm2
JM-TS...LA
F
a cavo 650
180ϒ
SAP-T
333
538
540
E40 1749 - JM-TS 2000W FS
ASIM. 63°
1080 960 840 720
403 140 280 380 540
600 480
ø21
360 240 120
+
cd/klm
-90ϒ -60ϒ -30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ 150
-
Reflector: asymmetric and symmetric polished 99.85 aluminium, anodised and polished, with light beam recovering fin. The asymmetric version emits a 63° light flux.
1749 Area - asymmetric FS wattage
colour
weight
S
code
weight
S+L
code
weight
CNR hot start code
Lamps (Ta=25°C) Kelvin - ølm - Ra
Max-TS 1000LA silver+graphite 23.00 415130-00 23.00 415130-99 Max-TS 2000LA silver+graphite 23.00 415131-00 23.00 415131-99 SAP-T 1000 silver+graphite 23.00 415132-00 2000K - 130000lm - Ra 4 To be used with acc 1177. With standard igniter located inside the special nylon box. For long arc lamps (choose type and colour temperature). On request: asymmetric luminous beam 55°. Hot start version supplied with acc. 1177 (17,60 kg). Other versions: please note if order lamp with subcode -49, order EXTERIOR FLOODLIGHTS with subcode -49. The floodlight with subcode-49 is not suitable for hot start.
Bario
246
Housing/Frame: die-cast aluminium with cooling fins. Components nylon box. Diffuser: tempered glass protection surface, 5 mm thick, resistant to impact and thermal shock. Coating: in several stages. First stage: black epoxy cationic electrocoating after a phosphochromate treatment, resistant to corrosive and saline environments. Second stage: UV stabilising priming; final stage: rough finish with frosted silver acrylic paint. Electric gear: 230V-50Hz power supply with heat protection. Wire terminated with admiralty brass clamps; double insulation; crosssection: 1 sqmm. 2P terminal block (maximum allowed lead cross section 2.5 sqmm.)
acc. 147 265
black
Equipment: silicone rubber gasket. Fibreglass nylon cable gland, Ø 1/2 gas. Retained stainless steel screws. Steel bracket with protractor scale. Hinge-opening front frame.
conveyor 995735
ø 316
Made of steel. Used for conveying the light beam in a single direction. To be used for art. Star/Bario. 70
acc. 333
173
164
ø10
black
140
acc. 148
pole mount ø60 997915
Made of aluminium. For installation onto pole ø 60.
baffle louvre 995736
black
60
Made of steel. To reduce glare and improve light control. To be used for art. Star/Bario.
ø 316 ø60
0ϒ
900cm2
JMTS
EN EC
IP66IK08
F
Rx7s
180ϒ
HCI-T
393
beam opening transv. 2x2,5° long. 2x2,5°
336
G12 1706 - CDM-T 150
274 70 70
292
ø1
4
Reflector: aluminium 99.85, anodised 3µ and polished.
UV
STOP
1705 Bario - wide beam
CNRL wattage
JM-TS JM-TS JM-TS JM-TS
colour
150 150 150 150
s. s. s. s.
silver silver silver silver
weight
code
8.00
411660-00 8.00 8.00 8.00 CNRL
wattage
colour
HCI-T 150 JM-TS 150 JM-TS 150 JM-TS 150 JM-TS 150
s. s. s. s. s.
silver silver silver silver silver
CNRL - coloured lamps
weight
weight
code
8.00 8.00
411661-00 411665-00
Lamps (Ta=25°C)
code
Kelvin - ølm - Ra
411660-96 411660-97 411660-98
4200K - 12000lm - Ra 1b blu verde magenta
1706 Bario - narrow beam CNRL - coloured lamps
weight
8.00 8.00 8.00
code
411665-96 411665-97 411665-98
CELL
Lamps (Ta=25°C)
weight
code
Kelvin - ølm - Ra
7.80
411661-08
3000K - 14000lm - Ra 1b 4200K - 12000lm - Ra 1b blue green magenta
Star EN EC
IP65IK08
247 0ϒ
986cm2
JMTS
F
Rx7s
390
180ϒ
SAP-TS
385
1147 - JM-TS 150
420
ø 330
Rx7s beam opening transv. 2x13° long. 2x7,5°
360 ø 15x30
140 100
100
Housing/Frame: die-cast aluminium with cooling fins.
UV
STOP
Diffuser: tempered glass protection surface, 5 mm thick, resistant to impact and thermal shock. Coating: in several stages. First stage: black epoxy cationic electrocoating after a phosphochromate treatment, resistant to corrosive and saline environments. Second stage: UV stabilising priming; final stage: rough finish with frosted silver acrylic paint. Electric gear: 230V-50Hz power supply with heat protection. Wire terminated with admiralty brass clamps; double insulation; crosssection: 1 sqmm. 2P terminal block (maximum allowed lead cross section 2.5 sqmm.) EN EC
IP65IK08
1147 Star - wide beam
CNRL
CNRL - coloured lamps
wattage
colour
weight
code
JM-TS 250 SAP-TS 150 JM-TS 150 JM-TS 150 JM-TS 150 JM-TS 150
s. s. s. s. s. s.
12.20 12.50 10.70
412826-00 412827-00 412828-00
silver silver silver silver silver silver
12.50 12.50 10.00
Lamps (Ta=25°C)
code
Kelvin - ølm - Ra
412828-96 412828-97 412828-98
4200K - 20000 lm - Ra 1b 2000K - 15000 lm - Ra 4 4200K - 12000 lm - Ra 1b blue green magenta
weight
986cm2
JM-T
F
G12
390
0ϒ 180ϒ
beam opening transv. 2x2,5° long. 2x2,5°
385
1147 - JM-T 150
420
ø 330
EXTERIOR FLOODLIGHTS
Reflector: wide beam aluminium 99.85, anodised 3µ and polished.
360 ø 15x30
140 100
100
Reflector: narrow beam aluminium 99.85, anodised 3µ and polished.
UV
STOP
1147 Star - narrow beam CNRL
Lamps (Ta=25°C)
wattage
colour
weight
code
Kelvin - ølm - Ra
JM-T 150
s. silver
10.60
412825-00
4200K - 13000lm - Ra 2a
acc. 134 4
ø 215
blue red green yellow
coloured filter 990001 990002 990003 990004
Colour glass to create special light effects. For JM-T150-1147 version only.
Tex
248 HCI...T
2500cm2
IP66IK08 F
G12 JM-T
203
E40 SAP-T 351
E40
632
-
3130 - SAP-T 150 9400 8460 7520 6580 5640 4700 3760 2820 1880 940
281
+
cd/klm
120ϒ 90ϒ 60ϒ 30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
Optical art. 3130
ø 400
Housing/Frame and outside reflector: die-cast aluminium with wide cooling fins. Reflector: in polished 99,85 aluminium with glass protection. Coating: In several stages. First stage: grey epoxy-cationic electrocoating, resistant to corrosive and saline environments . Second stage: UV stabilising priming; final stage: rough finish with frosted acrylic paint. Electric gear: 230V/50Hz power supply with heat protection. Flexible wire terminated with quick-connect admiralty brass clamps, silicone insulation with fibreglass braid, cross-section: 1 sqmm. 2P+T terminal block (maximum allowed lead cross-section: 2.5 sqmm). Equipment: Rubber cable gland, Ø _” gas thread (min. cable Ø 9, max Ø12).
UV
STOP
LED 3130 Tex - narrow beam CNRL
silver silver silver silver
+ + + +
graphite graphite graphite graphite
code
Kelvin - ølm - Ra
12.30 13.20 11.00 11.50
326020-00 326021-00 326022-00 326023-00
4200K - 14500lm - Ra 2a 4000K - 20000lm - Ra 2b 2000K - 15000lm - Ra 4 2000K - 28000lm - Ra 4
acc. 330 230
s. silver graphite 530
252
In die-cast, cationic electrocoated aluminium. For use with acc. 352.
acc. 352 210
single frame 998062 998063
inox
30
acc. 329 73
s. silver graphite 1026 252
bracket for frame 998080
In sheet steel. To use itself with the acc. 330 for the application to wall.
graphite
acc. 331
230
HCI-T 150 JM-T 250 SAP-T 150 SAP-T 250
Lamps (Ta=25°C)
weight
bracket for frame 998066 998067
s. silver graphite
385
In steel sheet. For the installation to wall or earth.
suspens. connection 998061
Made of aluminium. To use for suspension.
In die-cast, cationic electrocoated aluminium. For use with acc. 352.
acc. 332
214
double frame 998064 998065
305
colour
255 ø365
wattage
acc. 93 black
conveyor 995708
Used for conveying the light beam in a single direction. 70
85
Bracket with adjustment protractor scale for accurate aiming of the floodlight. Supplied with fixing pin to prevent aiming variations.
Installation to wall of two fixtures with acc. 331 and bracket acc. 352.
40ϒ
15ϒ 15ϒ
40ϒ
Tex
249 HCI...T
IP66IK08 F
2500cm2
G12 203
JM-T
3131 - SAP-T 150
E40 SAP-T
351
E40
281
632
+
550 495 440 385 330 275 220 165 110 55
-
cd/klm
80ϒ 60ϒ 40ϒ 20ϒ 0ϒ 20ϒ 40ϒ 60ϒ 80ϒ
Optical art. 3131
ø 400
Reflector: in polished 99,85 aluminium with glass protection.
UV
EXTERIOR FLOODLIGHTS
STOP
3131 Tex - medium beam
Mall - South Africa
CNRL
wattage
colour
HCI-T 150 JM-T 250 SAP-T 150 SAP-T 250
silver silver silver silver
+ + + +
graphite graphite graphite graphite
Lamps (Ta=25°C)
weight
code
Kelvin - ølm - Ra
12.30 13.20 11.00 11.50
326030-00 326031-00 326032-00 326033-00
4200K - 14500lm - Ra 2a 4000K - 19000lm - Ra 2b 2000K - 15000lm - Ra 4 2000K - 28000lm - Ra 4
HCI...T
IP66IK08 F
2500cm2
G12 203
115ϒ
JM-T
105ϒ 95ϒ 85ϒ 75ϒ
E40 351
SAP-T
65ϒ
632
E40 FLC...P/E
55ϒ 45ϒ
281
2G8
115ϒ
3132 - SAP-T 250 50 100 150 200 250
105ϒ 95ϒ 85ϒ 75ϒ
+ -
65ϒ 55ϒ 45ϒ
300 35ϒ 35ϒ cd/Klm 25ϒ 15ϒ 5ϒ 350 5ϒ 15ϒ 25ϒ
Optical art. 3132
ø 400
Reflector: in polished 99,85 aluminium with glass protection.
UV
STOP
3132 Tex - wide beam
Jury’s Inn - Milton Keynes (England)
CNRL
wattage
colour
HCI-T 150 JM-T 250 SAP-T 150 SAP-T 250 FLC 85 P/E
silver silver silver silver silver
+ + + + +
graphite graphite graphite graphite graphite
weight
code
12.30 13.20 11.00 11.50
326040-00 326041-00 326042-00 326043-00
weight
9.00
CELL
Lamps (Ta=25°C)
code
Kelvin - ølm - Ra
326044-00
4200K - 14500lm - Ra 2a 4000K - 19000lm - Ra 2b 2000K - 15000lm - Ra 4 2000K - 28000lm - Ra 4 4000K - 6000 lm - Ra 1b
Forum
250 0ϒ
1800 cm2
EN EC
IP65IK08
a cavo
180ϒ
1156 - JM-TS 2000 FS
590
477
beam opening transv. 2x3,5° long. 2x4,5°
L’ENERGIA CHE TI ASCOLTA.
295
530 100
100
ø15
498
+ -
Housing/frame: die-cast aluminium with cooling fins. Reflector: narrow beam aluminium 99.85, anodised and polished, with light beam recovering fin.
colour
weight
MAX-TS 1000 MAX-TS 2000
graphite graphite
12.90 12.90
CNR hot start
code
weight
code
412570-00 412573-00
35.00 35.00
412570-99 412573-99
To be used with acc 1177. With standard-supply igniter located inside the special fibreglass nylon box. Hot start version supplied with acc. 1177.
acc. 163
650 355
galvanised
650
Electric gear: wire terminated with admiralty brass clamps, silicone insulation with fibreglass braid, cross section: 2.5 sqmm 2P+T nylon terminal block (maximum allowed lead cross-section: 6 sqmm).
steel pole mount 998094
To be used to install up to 4 Forum floodlights on steel poles.
Equipment: supplied with knife switch enabling safe lamp replacement. Steel bracket with protractor scale and aiming visor. Retained steel screws with special anticorrosion and anti-gripping treatment. Igniter box thermally isolated from the housing. With gasket made of silicone platinic material.
ø 140
acc. 111 black
acc. 112 black
conveyor 995725
Made of steel. Used for conveying the light beam in a single direction. Can be installed with acc. 111
70
acc. 1177 gear CC IP65 JM-TS 1000 997640-00 JM-TS 2000 997642-00 Aluminium box with removable steel gear tray. Contents: ballast and capacitor. Included in standard supply: fibreglass nylon box with ignitor. Fitted for insertion of power supply cable. Steel bracket with protractor scale. Aiming visor for precise aiming of the floodlight.
110
347 ø 480
protective guard 995723
Plastic-coated steel rod. For protection against impact. Can be installed with acc. 112.
ø 418
Coating: graphite grey polyester powder coating, resistant to corrosive and saline environments.
480
acc. 113 black
baffle louvre 995724
Made of steel. To reduce glare and improve light control. 412
1177 JM-TS 1000 JM-TS 2000
gear tray 997640-16 997642-16
Steel gear tray only, no box. Contents: ballast and capacitor.
The lamp compartment opens on hinges, and when open stays attached to the housing for easy maintenance, while the aiming remains unchanged. On request: special glass to be used when the floodlight is aimed upwards with a tilt angle between 130° to 175°.
130ϒ
S
wattage
175ϒ
1156 Forum FS
Diffuser: tempered glass 5 mm thick, resistant to impact and thermal shock. Ideal for longer duration of the electrical and improved luminous efficiency.
Forum EN EC
251 0ϒ
1800 cm2
IP65IK08 a cavo
180ϒ
590
477
beam opening transv. 5,5+7,5° long. 2x7,5° L’ENERGIA CHE TI ASCOLTA.
295
530 100
100
ø15
1156 - JM-TS 2000 FM 8300 7470 6640 5810 4980 4150 3320 2490 1660 830 cd/klm
120ϒ 90ϒ 60ϒ 30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
498
+ EXTERIOR FLOODLIGHTS
Reflector: medium beam aluminium 99.85, anodised and polished, with light beam recovering fin.
1156 Forum FM S
CNR hot start
wattage
colour
weight
code
weight
code
MAX-TS 1000 MAX-TS 2000
graphite graphite
12.90 12.90
412571-00 412574-00
35.00 35.00
412571-99 412574-99
To be used with acc 1177. With standard-supply igniter located inside the special fibreglass nylon box. Hot start version supplied with acc. 1177.
EN EC
0ϒ
1800 cm2
IP65IK08 a cavo
180ϒ
1156 - JM-TS 2000 FM
590
477
beam opening transv. 2x11 long. 2x12
L’ENERGIA CHE TI ASCOLTA.
530 100
295 100
ø15
498
+ -
Reflector: wide beam prismatic aluminium 99.85, anodised and polished, with light beam recovering fin.
1156 Forum FL S
CNR hot start
wattage
colour
weight
code
weight
code
MAX-TS 1000 MAX-TS 2000
graphite graphite
12.90 12.90
412572-00 412575-00
35.00 35.00
412572-99 412575-99
To be used with acc 1177. With standard-supply igniter located inside the special fibreglass nylon box. Hot start version supplied with acc. 1177.
Forum lamps JM-TS1000/230V JM-TS2000/400V
986113 986118
4400K - 90000lm - 90 lm/W - Ra 1B 5900K - 200000lm - 100 lm/W - Ra 1A
Floodlights - distribution curves
252
Height pole m
SMALL SOCCER: 60 x 40 m
DOUBE TENNIS 36 x 36 m
TENNIS: 24 x11 - 36 x 18 m
BASKET: 28 x 15 m
SAMPLE PROJECT Articles:
Floodlight no. no. of per pole pole
total floodlights
Total wattage Kw
Aiming 0°
Inclination 0°
Initial average illum. General uniformity (depreciated by 20%) Emin / Em
1129 - JMT 400 8 2 4 8 3,5
40° 323°
-4° 0° 204 (163) .54
1158 - JMT 400 8 2 4 8 3,5
40° 322°
45° 44°
201 (161)
.54
1158 - JMT 400 FS 10 3 4 12 5,3
12° 309° 342°
36° 46° 310 (248) 36°
.82
1158 - JMT 400 FS 9 3 4 12 5,3
12° 309° 342°
38° 49° 322 (258) 38°
.82
1129 - JMT 400 9 3 4 12 5,3
8° 311° 366°
0° 0° 318 (254) 0°
.73
1129 - JMT 400 9 4 4 16 7,0
9° 305° 318° 357°
-5° 0° 0° 416 (333) -5°
1746 - JMTS 1000
12
2
4
8
8,4
0°
250 (207)
1158 - JMT 400 12 4 4 16 7,1 1746 - JMTS 1000 12 3 4 12 12,2
40° 55° 300° 54° 30° 61° 70 (56) 0° 59° 0° 195 (163)
1158 - JMT 400 FS 12 4 4 16 7,0
40° 30° 320° 295°
RACECOURSE "LE CAPANNELLE" ROME
1300/1000lux Photofinish + Rectilinear main U1=min/med=0,7 U2=min/max=0,5 800/600lux Curve + contrary rectilinear U1=min/med=0,6 U2=min/max=0,4
1.25
FLOODLIGHTS: N°548 1156 FORUM JMTS2000W 145 (FL), 180 (FM) 223 (FS) N°25 TOWERS: N°10 TOWERS H=25M CON 15pz N°6 TOWERS H=25M CON 18pz N°1 TOWERS H=35M CON 18pz N°3 TOWERS H=35M CON 24pz N°5 TOWERS H=40M CON 40pz Lux vertical direction TV
2.82
20.00
13 12 19.13
11 14 17.16
16.66
10
12.00
15.61
9 15
8 20.00
7
6
16 3.39
5 1.44
4
3.2
9
3
17
18
12.00
19
2
20
1
21
22
23 TRIB. ARR.
25
24 Anello in corda
Anello in corda
di rame da
50 mmq
di rame da
50 mmq
SPORTS HALL
35° 45° 50° 205 (164) 45°
Floodlights : 40x20 m Liable to be approved by CONI for professional contests and colour televising.
.71
.50
.70 .62
.67
Floodlights type: art.1125 Lampo Reflector: narrow beam JM-T 2000W Light flux 170.000 lm Total power 134,4 kW Height 16 m Total floodlight no. 64 Average horiz. illum. 3192 lux Average vert. illum. 1790 lux Gen. horiz. uniformity Ug = 0,70 Gen. vert. uniformity Ug = 0,63 An additional, no. 51 art. 1215 JM-E250 have been used for the illumination of the stands.
Floodlights - distribution curves 500
500
450
450
400
400
350
350
300
300
50
750 675 600 525 450 375 300 225 150 75
cd/klm
cd/klm
250
250
200
200
150
150
100
100
50 cd/klm
-120ϒ -90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
-120ϒ -90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
1158 (414066-00) - JM-T400
cd/klm
-120ϒ-90ϒ-60ϒ-30ϒ 0ϒ 30ϒ60ϒ90ϒ120ϒ
cd/klm
-120ϒ-90ϒ-60ϒ-30ϒ 0ϒ 30ϒ60ϒ90ϒ120ϒ
90ϒ 70ϒ 50ϒ 30ϒ
10 50 250
10ϒ -10ϒ -30ϒ -50ϒ -70ϒ cd/klm
100 25 -70ϒ-50ϒ-30ϒ-10ϒ10ϒ30ϒ50ϒ70ϒ90ϒ
cd/klm
50ϒ
500
30ϒ 10ϒ -10ϒ
100 25
-30ϒ -50ϒ -70ϒ cd/klm
-70ϒ-50ϒ-30ϒ-10ϒ10ϒ30ϒ50ϒ70ϒ90ϒ
90ϒ 70ϒ 50ϒ 30ϒ
750 675 600 525 450 375 300 225 150 75 -120ϒ-90ϒ-60ϒ-30ϒ 0ϒ 30ϒ60ϒ90ϒ120ϒ
-70ϒ cd/klm
90ϒ 70ϒ 50ϒ 30ϒ 10ϒ
250
10ϒ
500
-10ϒ -30ϒ -50ϒ -70ϒ
100 25
-90ϒ-70ϒ-50ϒ-30ϒ-10ϒ10ϒ30ϒ50ϒ70ϒ90ϒ
30ϒ 10ϒ
10 50 250 1000 2500
-10ϒ
100
-30ϒ
25
-50ϒ
500 100 25
cd/klm
-70ϒ-50ϒ-30ϒ-10ϒ10ϒ 30ϒ 50ϒ 70ϒ
-70ϒ-50ϒ-30ϒ-10ϒ10ϒ30ϒ50ϒ70ϒ90ϒ
1705 (411660-00) - JM-TS150 FL 70ϒ
10 50 250
50ϒ 30ϒ
500
10ϒ -10ϒ
-30ϒ
100
-50ϒ
25
-30ϒ -50ϒ
-70ϒ cd/klm
10 50 250
30ϒ
50ϒ
-10ϒ
-120ϒ-90ϒ-60ϒ-30ϒ 0ϒ 30ϒ60ϒ90ϒ120ϒ
50ϒ
70ϒ
10 50
-10ϒ -50ϒ
70ϒ
cd/klm
cd/klm
10ϒ -30ϒ
90ϒ
1148 (313340-00) - (313336-00) - JM-TS70
1159 (414164-00) - SAP-T400 600 540 480 420 360 300 240 180 120 60
10 50 250
70ϒ
1129 (412949-00) - JM-T250
1158 (414064-00) - SAP-T400 500 450 400 350 300 250 200 150 100 50
90ϒ
10 50 250 1000 5000 10000 2500 500 100 25
cd/klm
-70ϒ-50ϒ-30ϒ-10ϒ10ϒ 30ϒ 50ϒ 70ϒ
-70ϒ-50ϒ-30ϒ-10ϒ10ϒ30ϒ50ϒ70ϒ90ϒ
1149 (313343-00) - (313364-00) - JM-TS150
1706 (411665-00) - JM-TS150 FS 375
675
600
600
525
525
450
450
375
375
300
300
225
225
150
150
75
75
0
0
cd/klm
cd/klm
-120ϒ -90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
1125 FL (412641-00) - JM-T2000
1745 (415031-00) - JM-TS 2000
-120ϒ -90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
1746 (415111-00) - JM-TS 2000
REQUEST ANY MISSING DISTRIBUTION CURVES FROM OUR HEAD OFFICE OR CHECK IN OUR DLUX LIGHTING DESIGN SOFTWARE
See: collection of technical and lighting design information, regulations, technical data and explanatory tables
INFORMATION ON REGULATIONS
EXTERIOR FLOODLIGHTS
450 315 280 245 210 175 140 105 70 35
-120ϒ-90ϒ-60ϒ-30ϒ 0ϒ 30ϒ60ϒ90ϒ120
253
254
Tunnel, Gallery and underpass floodlights
Valsassina
Traforo di via del Tritone - Rome
Braga - Portugal
S. Giovanni Bianco - Bergamo (Italy)
255
The lighting of a tunnel in daytime has the purpose of ensuring that the traffic passing through it is provided with: safety, brightness, and comfort at least equal to those existing in road stretches before and after the tunnel. Tunnel lighting design is based on creating at the entrance a supporting lighting system whose initial value, sequence and amplitude depend on outside luminance and entering speed expected for that particular road.
Tunnel Rondo Zaba, Warsaw - Poland
Gallery - Autonomous Province of Trento
Cross City Tunnel - Sidney (Australia)
TUNNEL-GALLERY FLOODLIGHTS
Tunnel, Gallery and underpass floodlights
Radon
256
E
S A2
105ϒ 95ϒ 85ϒ 75ϒ
1165 - FL 1x58 105
FL
CONSUMP. 58=B2 58=A2
65ϒ
210
65ϒ
315
55ϒ
420
45ϒ
525
IP65IK08
G13
105ϒ 95ϒ 85ϒ 75ϒ
55ϒ 45ϒ
EN EC
115ϒ
350 155
58W= 5208cm2
115ϒ
ASYMM. 35° EFF.TOT. 67,6 %
35ϒ 35ϒ 630 25ϒ 15ϒ 5ϒcd/Klm5ϒ 15ϒ 25ϒ
FL
58W= 5208cm2
1680
G13 1166 - FL 2x58 20
CONSUMP. 58=B2 58=A2
60
+
EFF.TOT. 57,7 % e/h = 1,25
100
-
Housing/frame: made of extruded anodised aluminium with die-cast end caps and wide cooling fins. Supplied with 10 hooks.
140
BZ = 5/0.8-4
180
Diffuser: 4 mm thick,silk-screen printed tempered glass, resistant to impact and thermal shock (UNI7142 tests, British standard 3193).
220 260
1165 Radon - FL asymmetric XTreme wattage
colour
CELL-F
weight
Coating end caps and hooks: in various stages. First stage: epoxy cationic electrocoating, resistant to corrosive and saline environments. The second stage is a UV stabilizing priming.
Lamps (Ta=25°C) Kelvin - ølm - Ra
code
FL 1x58 m. silver 20.00 413033-00 Life lamps: 60.000 hours with electronic ballast 100.000 hours.
4000K - 5200lm - Ra 1b
1166 Radon - XTreme wattage
colour
CELL-F
weight
Lamps (Ta=25°C) Kelvin - ølm - Ra
code
FL 2x58 m. silver 20.00 413233-00 Life lamps: 60.000 hours with electronic ballast 100.000 hours.
4000K - 5200lm - Ra 1b
With lamps designed to last through time. They require very little maintenance, reducing servicing costs while offering excellent performance. The working life of the lamp is far more superior than that of standard lamps, the electronic ballast/reactor also lasts 100.000 hours.
SAP-T
1860 cm2
Electric gear: 230V/50Hz power supply. Hard wire, cross section 0.50 sqmm, and high-temperature resistant (up to 90°C) PVC-HT sheath, in accordance with CEI 2020 standards. 2P+T terminal block (maximum allowed lead cross-section: 4 sqmm).
EN EC
IP65IK08
E40
Îxä £xx
JM-T E40 1167 - SAP-T 150
EFF.TOT. 68.7 %
cd/klm
450
BZ = 3/1.0-2
400 350 300
-
250 200 150 100
ÈääÉÇnä
50 0 -120ϒ -90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
Housing/frame: made of extruded anodised aluminium supplied with no. 6 hooks. Reflector: polished high-gloss aluminium 99.85, anodised 3µ.
1167 Radon wattage
colour
m. silver SAP-T 150 m. silver SAP-T 250 Equipped with an air-circulation valve.
weight
9.00 9.50
acc. 91 stainless steel
100 160
25
1167 Radon
CNR code
413356-00 413357-00
mounting bracket 997905
In stainless steel. Complete with steel screws. Used for fixed mounting directly on ceiling or wall.
wattage
colour
weight
S code
m. silver 9.00 413354-00 JM/SAP-T 1000 To be used with electric gear box separated from the lamp compartment (acc. 1177). Equipped with an air-circulation valve.
acc. 92
pivoting bracket 997906
ø 92 190 190
silver
200
+
Made of steel with stainless steel mounting units. For 90° fixture rotation. With protractor scale.
60
450
Radon
257 SBP90 3007cm2
SBP
IP65IK08
SBP135 3782cm2
SBP180 4850cm2
By22d
£xx
Îxä
1167 - SBP 90
+ -
Housing/frame: made of extruded anodised aluminium with die-cast end caps and wide cooling fins. Supplied with 10 hooks: SBP 55 = 6 SBP 90 = 6 SBP135 = 8 SBP180 = 10 Reflector: polished high-gloss aluminium 99.85, anodised 3µ.
1167 Radon wattage
colour
weight
m. silver 16.25 SBP 55 m. silver 19.10 SBP 90 m. silver 22.30 SBP 135 m. silver 22.40 SBP 180 Equipped with an air-circulation valve.
EN EC
TUNNEL-GALLERY FLOODLIGHTS
ääÉ ÇäÉ£ÓÓäÉ£xÈx
CNR code
413341-00 413342-00 413343-00 413344-00
JM-T
IP65IK08
1860cm2
E40
Îxä £xx
SAP-T E40 beam opening transv. 2x39° long. 2x43°
1167 - JM-T 1000 400 300
+
200 100
ÊÊÊÊÊÊÊÊ£ÓÓäÉ£Înä
cd/klm
80ϒ 60ϒ 40ϒ 20ϒ 0ϒ 20ϒ 40ϒ 60ϒ 80ϒ
Housing/frame: made of extruded anodised aluminium with die-cast end caps and wide cooling fins. Supplied with 8 hooks. Reflector: polished high-gloss aluminium 99.85, anodised 3µ. This two-lamp version provides a better colour rendering, making the fixture usable in any architectural context (e.g. façade lighting, etc.) 2x70, 2x100, 2x150, 2x250W version available on request.
1167 Radon wattage
colour
m. silver 28.80 JM/SAP-T 1000 29.30 2xSAP/JM-T 400 m. silver Equipped with an air-circulation valve.
code
413352-00 413351-00
stainless steel
997643
IP657 aluminium box with gear tray. Weight 13.9kg. Max. distance from fixture 3m.
CNR
acc. 157
acc. 1177 gear CC IP65 SAP-T/JM-T 1000
weight
180 320
240
hook for Ø60 tube 998091
To be used when installing the floodlight on a Ø60 tube. 2 per pack.
-
Gallery
258
Housing: made of AISI 304 stainless steel drawn in a single high mechanical resistance piece. Supplied with stainless steel frame.
Santo Domingo - Dominican Republic
Diffuser: Thermal shock and impact resistant tempered glass (UNI 7142 British Standard 3193 tests). Electric gear: 230V-50Hz power supply with heat protection. Wire terminated with admiralty brass clamps, silicone insulation with fibreglass braid; cross section: 1.5 sqmm 2P+T terminal block (maximum allowed lead cross-section: 4 sqmm). Equipment: Rubber gasket. Fibreglass nylon cable gland, Ø 1/2 gas. Supplied with ceiling mounting bracket. On request: brass cable gland. Equipped with an air-circulation valve.
acc. 996
60
150
stainless steel
80
Made of stainless steel for the Gallery series. For suspension and rotation. 2 per pack.
245
ø 10
100
2250cm2
acc. 127 stainless steel bracket stainless steel 998079
800
Anti-condensation system with exhaust valve enabling the air to circulate without affecting the degree of protection.
adjustable bracket 166670
60 270
SAP-T
For art. 1992/3/4. Enables suspension installation and quick connection. For tunnels, high-speed resistant. Option to install a connector for electric connection.
IP65IK08
E40 105
beam opening transv. 2x40° long. 2x49°
317
1993 - SAP-T 250 FL
732
+ Reflector: symmetric, made of hammered aluminium 99.85, onelamp, narrow beam or wide beam type.
1993 Gallery - one-lamp FL
1992 Gallery - one-lamp FS
CNR
CNR
wattage
SAP-T SAP-T SAP-T SAP-T
100 150 250 400 *
colour
weight
code
wattage
natural natural natural natural
10.50 11.50 12.50 13.00
413111-00 413112-00 413113-00 413114-00
SAP-T SAP-T SAP-T SAP-T
Double insulation provided on request. * SAP-T 400: to be used with acc. 996.
100 150 250 400 *
colour
weight
code
natural natural natural natural
10.50 11.50 12.50 13.00
413121-00 413122-00 413123-00 413124-00
Double insulation provided on request. * SAP-T 400: to be used with acc. 996.
NOTE: upon request, one-lamp versions can be supplied with a quick plug-socket connector.
Gallery
259
IP65IK08
SAP-T
2250cm2
E40 105
beam opening transv. 2x66° long. 2x49°
317
1994 - SAP-T 100
732
+ Reflector: made of hammered aluminium 99.85, asymmetric wide beam or street type.
1997 SAP-T 250
700 630 560 490 420
TUNNEL-GALLERY FLOODLIGHTS
350 280
NOTE: upon request, one-lamp versions can be supplied with a quick plug-socket connector.
210 140 70 cd/klm
-120ϒ -90ϒ-60ϒ-30ϒ 0ϒ 30ϒ 60ϒ 90ϒ 120ϒ
1994 Gallery - one-lamp street type
1997 Gallery - asymmetric
CNR
wattage
SAP-T SAP-T SAP-T SAP-T
100 150 250 400 *
CNR
colour
weight
code
wattage
natural natural natural natural
10.50 11.50 12.50 13.00
413131-00 413132-00 413133-00 413134-00
SAP-T SAP-T SAP-T SAP-T
100 150 250 400 *
colour
weight
code
natural natural natural natural
10.50 11.50 12.50 13.00
413141-00 413142-00 413143-00 413144-00
Double insulation provided on request. * SAP-T 400: to be used with acc. 996.
Double insulation provided on request. * SAP-T 400: to be used with acc. 996.
SAP-T
IP65IK08
4100cm2
105
E40
317 1996 - SAP-T 2x50 FL 400 360 320 280 240 200 160 120 80 40
1332
+ -
cd/klm
80ϒ 60ϒ 40ϒ 20ϒ 0ϒ 20ϒ 40ϒ 60ϒ 80ϒ
Reflector: symmetric, made of hammered aluminium 99.85, narrow beam or wide beam type.
1996 Gallery - two-lamp FL
1995 Gallery - two-lamp FS
CNR
CNR
wattage
colour
weight
code
SAP-T 2x100 SAP-T 2x150 SAP-T 2x250
natural natural natural
10.50 11.50 12.50
413211-00 413212-00 413213-00
wattage
colour
weight
code
SAP-T 2x100 SAP-T 2x150 SAP-T 2x250
natural natural natural
10.50 11.50 12.50
413221-00 413222-00 413223-00
260
Boro inox AISI 316 L Housing: Drawn stainless sheet steel (AISI 316 L, thickness 8/10). Diffuser: Tempered glass 5 mm thermal shock and impact resistant. Equipment: The glass is siliconesealed onto the housing. Fibreglass nylon cable gland, Ă˜ 1/2 gas. Retained stainless steel screws with special anticorrosion, anti-gripping treatment. Thermally isolated watertight control gear box. Standard supply: Equipped with an air-circulation valve. During maintenance the lampholder cup stays attached by a safety steel cord. With or snap-on system.
Art. 1715/1716 complete with quick fixings for steel trunking.
Counter-flow lighting In the counter-flow lighting technique, the lighting fixture is aimed in the direction opposite to the flow of traffic. This helps observers to perceive the objects on the roadway as vividly highlighted against the background. Additionally, aiming the lighting fixture mostly towards observers results in higher luminous efficacy on the roadway.
IP65IK08
1174 SAP-T SAP-T SAP-T SAP-T
100 150 250 400
gear box for Boro 997610 997611 997612 997613
Fixings on trunking.
IP65IK08
Lateral quick and easy lamp extraction allows to leave unaltered the direction.
Anti-condensation system with exhaust valve enabling the air to circulate without affecting the degree of protection.
1205 SAP-T SAP-T SAP-T SAP-T
100 150 250 400
gear box for Boro 997620 997621 997622 997623
Boro inox AISI 316 L
261 2000cm2
SAP-T
IP65IK08
E40 ASYMM. 52°
454
528
1715 - SAP-T 400
+ 495
314
-
TUNNEL-GALLERY FLOODLIGHTS
Reflector: asymmetric; 99.85 anodised and polished aluminium.
1715 Boro - asymmetric counter-beam S
wattage
colour
SAP-T 100/400
stainless steel
weight
code
8.10
412752-00
2000cm2
SAP-T
IP65IK08
E40
105ϒ 95ϒ 85ϒ 75ϒ
454
528
115ϒ
65ϒ
495
55ϒ
314
45ϒ
115ϒ
1716 - SAP-T 400 30 90 150 210 270
105ϒ 95ϒ 85ϒ 75ϒ 65ϒ
45ϒ
330 35ϒ 35ϒ cd/Klm 25ϒ 15ϒ 5ϒ 390 5ϒ 15ϒ 25ϒ
Reflector: symmetric; 99.85 anodised and polished hammered aluminium.
1716 Boro - symmetric wattage
colour
SAP-T 100/400
stainless steel
S
weight
code
8.10
412762-00
+
55ϒ
-
Sicura
262
Housing: complete with graphite aluminium frame with die-cast aluminium end caps.
Croatia
Diffuser: 4 mm frosted and tempered glass, resistant to thermal shock. Coating: with graphite grey polyester powder, resistant to corrosive and saline environments. Electric gear: 230-240V / 50/60 Hz power supply with electronic ballast. Hard wire, cross-section 0.50 sqmm, and high-temperature resistant (up to 90°C) PVC-HT sheath, in accordance with CEI 20-20 standards. 2P terminal block (maximum allowed lead cross-section 2.5 sqmm.). Equipment: snap-lock optic unit secured with safety screws. Fibreglass nylon cable gland ø 1/2 gas thread.
TUNNELS IN THE LINK ROAD BETWEEN THE LECCO THROUGH CARRIAGEWAY AND VALSASSINA - ITALY 2259 pcs. 999 FORMA 2x54W lighting fixtures 135 pcs. 1997 GALLERY AS. SAP-T150W lighting fixtures 200 pcs. 1997 GALLERY AS. SAP-T250W lighting fixtures 261 pcs. 1997 GALLERY AS. SAP-T400W lighting fixtures
Lighting project 8.00
6.00
4.00
2.00
0.00
O
0.00
2.00
4.00
6.00
8.00
10.00
12.00
14.00
16.00
18.00
20.00
22.00
24.00
26.00
10.00
5.00
0.00
O
0.00
5.00
10.00
15.00
Wall mounting with acc. 311
20.00
25.00
30.00
35.00
40.00
45.00
50.00
55.00
60.00
HOSPITAL ENTRANCE: Length of reinforcement section: 160m. reinforcement 160m -92cd/m2 reinforcement 230 -59cd/m2 reinforcement 330m -23cd/m2 reinforcement 430m -12cd/m2 A constant LUMINANCE of 4cd/m2 is guaranteed in the INTERNAL area by the permanent lighting system using the 999 Forma FL2x54w (special) lighting fixtures, and providing 2cd/m2 at NIGHT.
SLAUGHTERHOUSE ENTRANCE: Length of reinforcement section: 160m. reinforcement 160m -123cd/m2 reinforcement 230m -62cd/m2 reinforcement 330m -30cd/m2 reinforcement 430m -18cd/m2 A constant LUMINANCE of 4cd/m2 is guaranteed in the INTERNAL area by the permanent lighting system using the 999 Forma FL2x54w (special) lighting fixtures, and providing 2cd/m2 at NIGHT. ‘I POGGI’ ENTRANCE Length of reinforcement section: 160m reinforcement 160m -103cd/m2 reinforcement 230m -59cd/m2 reinforcement 330m -25cd/m2 reinforcement 430m -13cd/m2 A constant LUMINANCE of 4cd/m2 is guaranteed in the INTERNAL area by the permanent lighting system using the 999 Forma FL2x54w (special) lighting fixtures, and providing 2cd/m2 at NIGHT.
acc. 311
Floor or wall mounting with acc. 310
£Ç{
inox
bracket 993922
To install Sicura permanently on walls/ floors. 2 per pack.
ÈÈ
+90/-90
acc. 310
Çä
inox
adjustable connection 993923
To install Sicura on walls/floors. It can be adjusted and tilted. 2 per pack.
ÈÈ nÓ
Sicura IP65IK08
263 FL
F
G5
100
CONSUMP. A2 1726 - FL 2x24
SSS
20
140
60 100 140 180
646/946/1246/1546
220 260
Reflector: symmetrical in highgloss anodised aluminium.
S A2 LED
1726 Sicura - asymmetric T5 CELL
colour
FL FL FL FL FL FL FL FL
graphite graphite graphite graphite graphite graphite graphite graphite
1x24 1x39 1x49 1x54 2x24 2x39 2x49 2x54
Lamps (Ta=25°C)
weight
code
3.40 4.50 7.00 5.80 3.40 4.50 7.00 5.80
414210-00 414211-00 414212-00 414213-00 414220-00 414221-00 414222-00 414223-00
Kelvin - ølm - Ra
4000K 4000K 4000K 4000K 4000K 4000K 4000K 4000K
-
1750lm 3100lm 4300lm 4450lm 1750lm 3100lm 4300lm 4450lm
-
Ra Ra Ra Ra Ra Ra Ra Ra
1b 1b 1b 1b 1b 1b 1b 1b
SAP-T
F
E27
100
IP65IK08
wattage
1726 - SAP-T 70 30
140
90 150
+
210 270
730/1330
330 390
Reflector: symmetrical in highgloss anodised aluminium.
1726 Sicura - symmetric CNRL
wattage
colour
SAP-T1x70 SAP-T2x70
graphite graphite
Lamps (Ta=25°C)
weight
code
Kelvin - ølm - Ra
7.00 7.00
414216-00 414226-00
2000K - 6000lm - Ra 4 2000K - 6000lm - Ra 4
LED
TUNNEL-GALLERY FLOODLIGHTS
+