204,336 Rentable Square Feet - Built 1990 - 10 Floors
FACT SHEET BUILDING: GREEN ACCREDITATION:
LEED Gold Energy Star Certified
BUSINESS HOURS OF THE BUILDING:
Monday – Friday, 7:00 A.M. to 6:00 P.M. (excluding holidays).
SECURITY:
24 hour, 365 days a year onsite security officer supplemented by surveillance cameras at the loading dock and other locations.
PUBLIC ACCESS/TRANSPORTATION TO BUILDING:
Located in the Oakland Central Business District, near the intersection of Grand Avenue and Harrison Street just northwest of the shores of Lake Merritt. Close to public transportation and within walking distance of many restaurants and shops.
RETAIL SPACE IN BUILDING:
Bank of Alameda, Bay Commercial Bank, and Specialty’s Café & Bakery.
ELEVATOR SYSTEMS: NUMBER OF PASSENGER ELEVATORS:
Four passenger elevators and one hydraulic shuttle elevator (garage levels).
NUMBER OF FREIGHT ELEVATORS:
One freight elevator with card access control.
INSIDE DIMENSIONS OF THE FREIGHT ELEVATORS:
Width – 65”, Height – 132”, Depth – 98”.
TYPE OF ELEVATOR DRIVE SYSTEM:
Geared traction.
WIDTH AND HEIGHT OF FREIGHT ELEVATOR DOOR FRAME:
P1 Freight Elevator: Width – 48”, Height – 102” P2 Freight Elevator: Width – 48”, Height – 88”
1
HOURS OF AVAILABILITY FOR FREIGHT ELEVATOR RESERVATIONS:
Before 7:00 A.M. and after 6:00 P.M., Monday Friday, Weekends. Freight elevator can access tenant floors with programmed access card only. Vendors must check-out an access card for use.
PROCEDURE FOR FREIGHT ELEVATOR/LOADING DOCK RESERVATION:
Please notify the Management Office at least two days in advance of the moving date to schedule use of the loading dock and freight elevator. The loading dock and the freight elevator are available during non-business hours only with the written approval of the Management Office on a first come first serve basis.
PASSENGER ELEVATOR SPEED RATING:
Low Rise Elevators: 350 fpm.
FREIGHT ELEVATOR SPEED RATING:
Freight Elevator: 350 fpm.
LIGHTING: SPECIFICATION FOR BUILDING STANDARD LIGHTING:
New: Finelite Series HPR, Angled Luminaire Style 2’ x 4’, round center optic, 2-TB lamps, 277 volt, step dimming, bi-level ballast. Reuse: Fluorescent Light Fixtures 2’ x 4’ 18 cell parabolic fluorescent light fixture, frameless manufactured to appear as 2 – 2’ x 2’ 9 cell parabolic lights, 277 volt (Existing): Electronic Ballast, 3-T8 lamps, white reflector. Florescent lamp is: F28T8/ADV835/EW
ARE LIGHT FIXTURES AIR HANDLING FIXTURES?
No.
HOURS OF OPERATIONS:
6:00 am to 7:00 pm, Monday – Friday. After-Hours, Sunday and Legal Holidays provided at Tenant's expense.
CEILING: 8' 10" typical.
WHAT IS THE FINISHED CEILING HEIGHT:
2
TOP OF SLAB TO TOP SLAB HEIGHTS:
12' 9” (exceptions: 1st floor = 18’).
WHAT IS THE AVERAGE HEIGHT BETWEEN TOP OF SUSPENDED CEILING AND UNDERSIDE OF STRUCTURE ABOVE:
3 feet typical.
STANDARD CEILING TILE AND SUSPENSION SYSTEM:
Ceiling Tile: Armstrong #2195 24” x 24” x 3/4”, cortega lay-in beveled edge, non directional, tegular tile. Suspension System: 2’ x 2’ Donn Fineline, ¼’ reveal, heavy duty grid, low gloss white.
PLUMBING: NUMBER OF DRINKING FOUNTAINS WITH CHILLED WATER PER FLOOR:
One fountain per floor.
QUANTITY OF AND LOCATION FOR ACCESS TO DOMESTIC WATER ON EACH FLOOR:
One 11/2” cold water stub out is located on each floor above ceiling outside restrooms.
BOTH HOT AND COLD WATER AT THE BASE OF BUILDING LAVATORIES:
Yes.
IS THE BUILDING SPRINKLERED?
Yes.
HVAC:
The building has a central automation system for control of the HVAC. Each floor has a heating and cooling duct. Common air handler in Penthouse supplies heat to perimeter VAV boxes. Two chillers supply chilled water to all AHU’s. The chillers and cooling towers are located on the roof. There is one boiler located in the penthouse. Space temperature is maintained at 73 degrees.
HOURS OF HVAC OPERATION:
7:00 A.M. to 6:00 P.M., Monday – Friday. After-Hours, Sunday and Legal Holidays provided at Tenant's expense.
OVERTIME HVAC CAPACITY AND AVAILABILITY:
One week notice is required for Full HVAC services. The system can be set up for recurring needs.
3
AVERAGE COST OF HVAC PER HOUR:
Full HVAC charges are $70.00 per hour. These charges are subject to change based on market labor & utility rates.
ARE PUBLIC AREAS OF BUILDING CONSIDERED SMOKING OR NON-SMOKING?
Non-Smoking.
WHAT IS THE AGE OF THE HVAC EQUIPMENT?
Chillers - 20 Years. Boilers – Less than 2 Years.
WHAT TYPE OF THERMOSTATS IS USED IN THE BUILDING?
Trane Wall-Mount Temperature Sensor DDC. Mounting height + 48” A.F.F.
IF THERE IS A REQUEST FOR AFTER-HOURS AIR CAN THE SYSTEM BE STARTED/STOPPED REMOTELY?
Yes.
ELECTRICAL: RECEPTACLE CAPACITY IN WATTS PER SF:
1.6 watts PSF.
BUS RISER CAPACITY:
There is one bus riser with 3,000 amps capacity each at 277/480 volts.
LIGHTING CAPACITY:
1.5 watts PSF.
PRIMARY ELECTRICAL FEED VOLTAGE:
277/480 volt, 3 Phase & 120/208.
SUPPLIED FROM BUILDING SWITCHBOARD TO POWER CENTERS IN ELECTRICAL CLOSETS ON EACH FLOOR?
Yes.
WILL BASE BUILDING ALLOW FOR TENANT TO INCREASE Subject to engineering review and approval. CAPACITY IN ELECTRICAL CLOSETS ON EACH FLOOR? WHAT IS THE LIVE LOAD OF CAPACITY OF THE FLOORS:
Typical floor: 80 PSF
MAY TENANT CORE FLOOR PROVIDE ELECTRICAL VOICE AND DATA TO STAFF?
Yes, with approval and supervision.
SLAB CONSTRUCTION IS POST TENSIONED OR PAN CONSTRUCTION:
Pan Construction.
4
MISCELLANEOUS: BUILDING HAS CARD ACCESS AFTER HOURS:
Yes.
LOADING DOCK ENTRANCE IS CARD ACCESS AFTERHOURS:
No, however, loading dock visitors are screened via video capability by Security prior to access.
DOES THE BUILDING HAVE FIBER OPTICS?
Yes, both AT&T and Verizon.
DOES THE BUILDING HAVE CABLE?
Yes, from Comcast.
DOES THE BUILDING HAVE STORAGE?
4,023 RSF of garage storage is available for lease.
OFFICE DOORS AND HARDWARE:
Eggers Industries, Inc. Series Type: PC-5Ply flush 3’-0” (min.) x 8’-8 1/2” (+/-) solid core door, plain sliced oak, book matched. Pre-finish: water based transparent finish to match existing Eggers Industries, Inc. standard finish. Door hardware is Schlage L9050P, 07 lever, and 625 finish. Hardware finish is Bright Chrome, US 26D.
BUILDING STAIRWELLS COMPLETED:
Yes.
RECYCLING:
Commingled recycling and composting programs; battery and electronic recycling programs also in place.
ROOF TOP DISH ACCOMMODATIONS:
Yes, with Landlord consent and license fee, though access is limited.
ARE THE RESTROOMS ADA COMPLIANT?
Yes.
ARE THE ENTRIES ADA COMPLIANT?
Yes.
TYPE OF ROOF:
IRMA (Inverted Roof Membrane Assembly).
TYPE OF CONSTRUCTION:
Steel reinforced concrete.
PARKING:
5
TOTAL NUMBER OF PARKING SPACES:
219 stalls (105 on P1 level and 114 on P2 level).
NUMBER OF DEDICATED GREEN PARKING SPACES:
2 Electric Vehicle (EV) Charging Stations. 7 Alternative Fuel. 2 Smart Car. 2 Bicycle Parking Cages.
NUMBER OF DISABLED PARKING SPACES:
15.
OTHER AVAILABLE TRANSPORTATION SERVICES:
BART Shuttle transports tenants, visitors, and parkers to 19th Street BART station. Zip Car services available in garage.
COST FOR PARKING:
Transient Parking from 7:00 a.m. to 7:00 p.m.: $2.00 per ½ hour $14.00 per day, $11.00 early bird (in by 9:30 a.m.) Contract Parking (24 hours): $200/mo. (non-reserved) $225/mo. (reserved) $25 refundable key card deposit Validation Stamps: ½ hour increments, 1 hour increments, or all day stamps sold in books of 100 stamps each at the rates above. Subject to change. Propark 155 Grand Avenue, P1 Oakland, CA 94612 510-268-8605
PARKING MANAGER:
6