Smart Panels Technical guide Data acquisition with Acti9, Compact, Masterpact
schneider-electric.com
Measure Connect Act
www.schneider-electric.com
Energy management has never been simpler Smart Panels connect you to energy savings
This guide will help you to determine exactly how to equip the circuit breakers and other protective devices in the Acti9, Compact and Masterpact ranges, depending on the information to be acquired from each of them. This guide supplements the other Smart Panel design and construction documents.
Architecture guide
Catalogue
Data acquisition guide
Thank you for choosing Schneider Electric's exclusive Smart Panels, which can be fully connected directly to the company IT network, to help your customers improve their energy performance.
Measure Embedded and stand-alone metering & control capabilities
Connect > Integrated communication interfaces > Ready to connect to energy management platforms
2
Act > Data-driven energy efficiency actions > Real time monitoring and control > Access to energy and site information through on-line services
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
www.schneider-electric.com
5 types of information To determine the equipment required according to the information which will be useful to your customer, we can classify this information by making an analogy with a car.
Measurement
Availability
This is the speed indicator. Your customer has a real-time indication of their electricity consumption and can track its rise or fall.
These are the warning lights for the battery, tyre wear, or even the fuel gauge. If one of these lights up, a maintenance operation is required.
Metering
Controls
This is the car's odometer.
These are the steering wheel levers. Just like the lights, horn, indicators, etc., signals from this control will switch the loads on or off.
Here, the circuit breakers indicate the electricity consumption.
Quality This is the rev counter. For the same electricity consumption, the installation may be over-used or under-used just like an engine over-revving or under-revving.
Two ways of accessing information
> D irectly via the front panel Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
> R emotely via the company IT network.
3
www.schneider-electric.com
Acti 9 Data acquisition
Metering
Quality
Measurement
Availability (states/statuses)
Control
Page no.
@
5 6 7
Architectures
@ @
Compact NSX 100-630 Data acquisition
Metering
Measurement
Quality
@ @ @
Availability (states/statuses)
@ @ @
Control
@ @
Page no.
8-9 10 - 11 12 - 13 14 - 15
Compact NS Masterpact NT/NW Data acquisition
Metering
Measurement
Quality
Availability (states/statuses)
@ @ @ @
Control
@ @
Page no.
18 - 19 20 - 21 22 - 23 24 - 25
Masterpact MTZ Data acquisition
Metering
Measurement
Quality
@ @
4
Availability (states/statuses)
Control
@
Page no.
26 27
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
www.schneider-electric.com
Acti 9 p
Availability Modular equipment, front panel display and remote view Enerlin’X FDM128 panel display RJ45 Ethernet Patchcord (ULP cables)
LV434128
TRV00803 (L = 0.3 m, Quantity 10) TRV00806 (L = 0.6 m, Quantity 10) TRV00810 (L = 1 m, Quantity 5) TRV00820 (L = 2 m, Quantity 5) TRV00830 (L = 3 m, Quantity 5) TRV00850 (L = 5 m, Quantity 1)
Acti 9 SmartLink SI B Ethernet A9XMZA08
/ACT 0-100 LK/1 ORK NETWUS STAT
COM
COM R
D1 D0
0V
T RNE ETHE
TSX CSA cable
US
STAT
8 7 6 5 4 3 2 1 0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
AI2 24V 0V AI1
0V
+24V
8
TSXCSA100 (L = 100 mm) TSXCSA200 (L = 200 mm) TSXCSA500 (L = 500 mm)
7 6
5 4
3 2
1
Mounting Kit Din Rail Linergy FM200 Back Pane
Acti9 SmartLink A9XMSB11
A9XMFA04 A9XM2B04 A9XMBP02
Prefabricated cables 2 x TI24 connectors A9XCA506 (L = 100 mm) A9XCAM06 (L = 160 mm) A9XCAH06 (L = 450 mm) A9XCAL06 (L = 870 mm)
DC +24V CMD SD OF 0V
11
12
14
OF
A
N .2.3 ode1 ex iC60 Ready-M I. ON O. OFF t Overhea
Refl A
N P
auto
OFF
Acti9 RCA, 230 V remote control unit for iC60
Acti9 Reflex: built-in remote-controlled breaker
Acti9 (iC60, ilD, iSW-NA) : A9A26987 Multi9 (C120, iDPN, C60H-DC) : A9N26899
A9C70122 (1P, 1P+N, 2P) A9C70124 (3P, 4P)
A9C62210 (2P, 10 A) ...
Auxiliary contacts for MCB and RCD
A9C62463 (4P, 63 A)
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
5
www.schneider-electric.com
p Acti 9
Control Modular equipment, front panel display and remote view Enerlin’X FDM128 panel display
RJ45 Ethernet Patchcord (ULP cables)
LV434128
TRV00803 (L = 0.3 m, Quantity 10) TRV00806 (L = 0.6 m, Quantity 10) TRV00810 (L = 1 m, Quantity 5) TRV00820 (L = 2 m, Quantity 5) TRV00830 (L = 3 m, Quantity 5) TRV00850 (L = 5 m, Quantity 1)
Acti 9 SmartLink SI B Ethernet A9XMZA08 /ACT 0-100 LK/1 ORK NETWUS STAT
COM
COM R
D1 D0
TSX CSA cable
0V
T RNE ETHE
US
STAT
TSXCSA100 (L = 100 mm) TSXCSA200 (L = 200 mm) TSXCSA500 (L = 500 mm)
8 7 6 5 4 3 2 1 0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
AI2 24V 0V AI1
0V +24V
8 7
6 5
4 3
2
Mounting Kit Din Rail Linergy FM200 Back Pane
1
Acti9 SmartLink Modbus RS485 A9XMSB11
A9XMFA04 A9XM2B04 A9XMBP02
Prefabricated cables 2 x TI24 connectors A9XCA506 (L = 100 mm) A9XCAM06 (L = 160 mm) A9XCAH06 (L = 450 mm) A9XCAL06 (L = 870 mm)
DC +24V CMD SD OF 0V
11
12
14
OF
T24 iAC iACT24
iCT
iATL24 A
N .2.3 ode1 ex iC60 Ready-M I. ON O. OFF t Overhea
Refl
A
N P
A9C15424
6
Acti9 iACT24 auxiliary for ICT switch A9C15924
OFF
Acti9, remote-controlled RCA 230 V for iC60 breaker
Acti9 Reflex: built-in remote-controlled breaker
A9C70122 (1P, 1P+N, 2P) A9C70124 (3P, 4P)
A9C62210 (2P, 10 A) ...
Acti9 iATL24 auxiliary for ITL remote control switch
auto
A9C62463 (4P, 63 A)
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
www.schneider-electric.com
Acti 9 p
Metering Modular equipment, front panel display and remote view Enerlin’X FDM128 panel display
RJ45 Ethernet Patchcord (ULP cables)
LV434128
TRV00803 (L = 0.3 m, Quantity 10) TRV00806 (L = 0.6 m, Quantity 10) TRV00810 (L = 1 m, Quantity 5) TRV00820 (L = 2 m, Quantity 5) TRV00830 (L = 3 m, Quantity 5) TRV00850 (L = 5 m, Quantity 1)
Acti 9 SmartLink SI B Ethernet A9XMZA08 /ACT 0-100 LK/1 ORK NETWUS STAT
COM
COM R
D1 D0
TSX CSA cable
0V
T RNE ETHE
TSXCSA100 (L = 100 mm) TSXCSA200 (L = 200 mm) TSXCSA500 (L = 500 mm)
US
STAT
8 7 6 5 4 3 2 1 0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
AI2 24V 0V AI1
0V
+24V
8 7
6 5
4 3
2
Mounting Kit Din Rail Linergy FM200 Back Pane
1
A9XMFA04 A9XM2B04 A9XMBP02
Acti9 SmartLink Modbus RS485 A9XMSB11
Prefabricated cables 1 x Ti24 connector
PowerTag wireless energy sensor
A9XCAC01 (L= 4000 mm, Quantity 1) A9XCAU06 (L = 870 mm, Quantity 6) A9XC2412 (Ti24 connector) S0+
D0/-
D1/+
0V
C T2 C/-
ON
63A Imax:
Acti9 iEM3x10 kWh meter with partial counter, pulse output, MID certified iEM3110: direct connected 63 A iEM3210: 5 A transformer connected iEM3310: direct connected 125 A
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
D1
D0
N.C.
N.C.
ON
63A Imax:
iEM31
T1
iEM31
C/-
A9MEM1520 (1P top or bottom)) A9MEM1521 (1P+N - on top) A9MEM1522 (1P+M -at bottom) A9MEM1540 (top or bottom) A9MEM1541 (on top) A9MEM1542 (at bottom)
Acti9 iEM3x50, iEM3x55 kWh meter with partial counter, current, voltage and power mesurements Modbus RS485 MID certified iEM3150/3155: direct connected 63 A iEM3250/3255: 5 A transformer connected iEM3350/3355: direct connected 125 A
7
www.schneider-electric.com
p Compact NSX 100-630
Metering, Measurement, Quality Front panel display FDM121 panel display TRV00121
NSX cable (optional) LV434200 (L = 0.35 m) LV434201 (L = 1.3 m) LV434202 (L = 3 m)
ULP line terminations (pack of 10) TRV00880
Micrologic E circuit breaker control unit
Remote view Communication interface +24V 0V
ULP line terminations
(optional)
Eth2 Eth1
(pack of 10) TRV00880 R
TRV00210 (Modbus RS485 IFM) LV434010 (Ethernet IFE) LV434011 (Ethernet IFE + gateway function)
NSX cable (optional) LV434200 (L = 0.35 m) LV434201 (L = 1.3 m) LV434202 (L = 3 m)
Micrologic E circuit breaker control unit
8
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
www.schneider-electric.com
Compact NSX 100-630 p
Metering, Measurement, Quality Front panel display and remote view Communication interface
TRV00121
(optional) TRV00210 (Modbus RS485 IFM) LV434010 (Ethernet IFE) LV434011 (Ethernet IFE + gateway function) +24V 0V
Eth2 Eth1
R
NSX cable (optional) LV434200 (L = 0.35 m) LV434201 (L = 1.3 m) LV434202 (L = 3 m)
ULP line terminations (pack of 10) TRV00880
ULP RJ45 cables (optional) TRV00803 (L = 0.3 m, Quantity 10) TRV00806 (L = 0.6 m, Quantity 10) TRV00810 (L = 1 m, Quantity 5) TRV00820 (L = 2 m, Quantity 5) TRV00830 (L = 3 m, Quantity 5) TRV00850 (L = 5 m, Quantity 1)
Micrologic E circuit breaker control unit Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
9
www.schneider-electric.com
p Compact NSX 100-630
Metering, Measurement, Quality and Availability Front panel display FDM121 panel display TRV00121
NSX cable (optional) LV434200 (L = 0.35 m) LV434201 (L = 1.3 m) LV434202 (L = 3 m)
ULP line terminations (pack of 10) TRV00880
BSCM module LV434205
Micrologic E circuit breaker control unit
Remote view Communication interface (optional) TRV00210 (Modbus RS485 IFM) LV434010 (Ethernet IFE) LV434011 (Ethernet IFE + gateway function)
+24V 0V
Eth2 Eth1
NSX cable (optional) R
LV434200 (L = 0.35 m) LV434201 (L = 1.3 m) LV434202 (L = 3 m)
ULP line terminations (pack of 10) TRV00880
BSCM module LV434205
Micrologic E circuit breaker control unit
10
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
www.schneider-electric.com
Compact NSX 100-630 p
Metering, Measurement, Quality and Availability Front panel display and remote view Communication interface
FDM121 panel display
(optional)
TRV00121
TRV00210 (Modbus RS485 IFM) LV434010 (Ethernet IFE) LV434011 (Ethernet IFE + gateway function)
+24V 0V
Eth2 Eth1
NSX cable (optional) LV434200 (L = 0.35 m) LV434201 (L = 1.3 m) LV434202 (L = 3 m) R
BSCM module LV434205
ULP line terminations (pack of 10) TRV00880
ULP RJ45 cables (optional) TRV00803 (L = 0.3 m, Quantity 10) TRV00806 (L = 0.6 m, Quantity 10) TRV00810 (L = 1 m, Quantity 5) TRV00820 (L = 2 m, Quantity 5) TRV00830 (L = 3 m, Quantity 5) TRV00850 (L = 5 m, Quantity 1)
Micrologic E circuit breaker control unit
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
11
www.schneider-electric.com
p Compact NSX 100-630
Metering, Measurement, Quality, Availability and Control Front panel display FDM121 panel display TRV00121
ULP line terminations (pack of 10) TRV00880
NSX cable (optional) LV434200 (L = 0.35 m) LV434201 (L = 1.3 m) LV434202 (L = 3 m)
220/240 VCA smart remote control LV429441 (MTc NSX100/160) LV431549 (MTc NSX250) LV432652 (MTc NSX400/630)
BSCM module LV434205
Micrologic E circuit breaker control unit
Remote view Communication interface +24V 0V
(optional)
Eth2 Eth1
ULP line terminations (pack of 10) TRV00880
220/240 VCA smart remote control LV429441 (MTc NSX100/160) LV431549 (MTc NSX250) LV432652 (MTc NSX400/630)
R
TRV00210 (Modbus RS485 IFM) LV434010 (Ethernet IFE) LV434011 (Ethernet IFE + gateway function)
NSX cable (optional) LV434200 (L = 0.35 m) LV434201 (L = 1.3 m) LV434202 (L = 3 m)
BSCM module LV434205
Micrologic E circuit breaker control unit 12
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
www.schneider-electric.com
Compact NSX 100-630 p
Metering, Measurement, Quality, Availability and Control Front panel display and remote view
FDM121 panel display TRV00121
ULP RJ45 cables (optional)
Communication interface
TRV00803 (L = 0.3 m, Quantity 10) TRV00806 (L = 0.6 m, Quantity 10) TRV00810 (L = 1 m, Quantity 5) TRV00820 (L = 2 m, Quantity 5) TRV00830 (L = 3 m, Quantity 5) TRV00850 (L = 5 m, Quantity 1)
TRV00210 (Modbus RS485 IFM) LV434010 (Ethernet IFE) LV434011 (Ethernet IFE + gateway function)
(optional)
+24V 0V
Eth2 Eth1
NSX cable (optional) LV434200 (L = 0.35 m) LV434201 (L = 1.3 m) LV434202 (L = 3 m) R
220/240 VCA smart remote control LV429441 (MTc NSX100/160) LV431549 (MTc NSX250) LV432652 (MTc NSX400/630)
ULP line terminations (pack of 10) TRV00880
Micrologic E circuit breaker control unit
BSCM module LV434205
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
13
www.schneider-electric.com
p Compact NSX 100-630
Availability (states/statuses) and Control Front panel display FDM121 panel display TRV00121
ULP line terminations (pack of 10) TRV00880
NSX cable (optional) LV434200 (L = 0.35 m) LV434201 (L = 1.3 m) LV434202 (L = 3 m)
220/240 VCA smart remote control LV429441 (MTc NSX100/160) LV431549 (MTc NSX250) LV432652 (MTc NSX400/630)
BSCM module LV434205
For any circuit breaker control unit TMD, TMG, MA, Micrologic
Remote view +24V 0V
Eth2
Communication interface (optional)
Eth1
ULP line terminations (pack of 10) TRV00880
220/240 VCA smart remote control LV429441 (MTc NSX100/160) LV431549 (MTc NSX250) LV432652 (MTc NSX400/630)
R
TRV00210 (Modbus RS485 IFM) LV434010 (Ethernet IFE) LV434011 (Ethernet IFE + gateway function)
NSX cable (optional) LV434200 (L = 0.35 m) LV434201 (L = 1.3 m) LV434202 (L = 3 m)
BSCM module LV434205
For any circuit breaker control unit TMD, TMG, MA, Micrologic
14
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
www.schneider-electric.com
Compact NSX 100-630 p
Availability (states/statuses) and Control Front panel display and remote view
FDM121 panel display TRV00121
ULP RJ45 cables (optional)
Communication interface
TRV00803 (L = 0.3 m, Quantity 10) TRV00806 (L = 0.6 m, Quantity 10) TRV00810 (L = 1 m, Quantity 5) TRV00820 (L = 2 m, Quantity 5) TRV00830 (L = 3 m, Quantity 5) TRV00850 (L = 5 m, Quantity 1)
TRV00210 (Modbus RS485 IFM) LV434010 (Ethernet IFE) LV434011 (Ethernet IFE + gateway function)
(optional)
+24V 0V
Eth2 Eth1
NSX cable (optional) LV434200 (L = 0.35 m) LV434201 (L = 1.3 m) LV434202 (L = 3 m) R
220/240 VCA smart remote control ULP line terminations (pack of 10)
LV429441 (MTc NSX100/160) LV431549 (MTc NSX250) LV432652 (MTc NSX400/630)
TRV00880
BSCM module LV434205
For any circuit breaker control unit TMD, TMG, MA, Micrologic
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
15
www.schneider-electric.com
p Compact NSX 100-630
Drawout device (base or chassis) List of references I/O module (feeds back chassis "connected/disconnected" position via IFM or IFE communication interface)
+24V 0V
Eth2 Eth1
LV434063
9-wire fixed part block (base)
R
LV429273
9-wire mobile part block LV429274
CE/CD position contacts (installation on chassis) LV429287
Base for 2 mobile blocks LV429275
1
16
2
1
Disconnect the NSX cable from its terminal
2
Connect the ULP RJ45 cable to the fixed part block (base)
3
Connect the 4 wires of the mobile part block to the terminal
3
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
www.schneider-electric.com
Compact NSX 100-630 p
Drawout device (base or chassis) List of references I/O module (feeds back chassis "connected/disconnected" position via IFM or IFE communication interface)
+24V 0V
Eth2 Eth1
LV434063
R
9-wire disconnectable plug LV429272
CE/CD position contacts (installation on chassis) LV429287
3 1
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
1
Disconnect the NSX cable from its terminal
2
Connect the ULP RJ45 cable to the fixed part block
3
Connect 4 wires on the disconnectable plug to the terminal
2
17
www.schneider-electric.com
p Compact NS, Masterpact NT/NW
Metering, Measurement, Quality and Availability Fixed device, front panel display FDM121 panel display TRV00121
ULP line terminations (pack of 10) TRV00880
ULP device cord (optional) LV434195 (L = 0.35 m) LV434196 (L = 1.3 m) LV434197 (L = 3 m)
1 2
Device communication module (BCM ULP)* Micrologic E/P/H* circuit breaker control unit 1
* For control with the circuit breaker for factory conversion (Rapsodie listing or control network)
2
Fixed device, remote view Communication interface (optional)
+24V 0V
ULP line terminations
Eth2 Eth1
TRV00210 (Modbus RS485 IFM) LV434010 (Ethernet IFE) LV434011 (Ethernet IFE + gateway function)
(pack of 10) TRV00880 R
1 2
ULP device cord (optional)
Device communication module (BCM ULP)*
LV434195 (L = 0.35 m) LV434196 (L = 1.3 m) LV434197 (L = 3 m)
Micrologic E/P/H* circuit breaker control unit 1
* For control with the circuit breaker for factory conversion (Rapsodie listing or control network)
2
18
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
www.schneider-electric.com
Compact NS, Masterpact NT/NW p
Metering, Measurement, Quality and Availability Fixed device, front panel display and remote view ULP RJ45 cables (optional)
FDM121 panel display TRV00121
TRV00803 (L = 0.3 m, Quantity 10) TRV00806 (L = 0.6 m, Quantity 10) TRV00810 (L = 1 m, Quantity 5) TRV00820 (L = 2 m, Quantity 5) TRV00830 (L = 3 m, Quantity 5) TRV00850 (L = 5 m, Quantity 1)
Communication interface (optional) TRV00210 (Modbus RS485 IFM) LV434010 (Ethernet IFE) LV434011 (Ethernet IFE + gateway function)
+24V 0V
Eth2 Eth1
ULP device cord (optional) LV434195 (L = 0.35 m) LV434196 (L = 1.3 m) LV434197 (L = 3 m)
ULP line terminations (pack of 10) TRV00880
1 1 2
Device communication module (BCM ULP)* Micrologic E/P/H* circuit breaker control unit
* For control with the circuit breaker for factory conversion (Rapsodie listing or control network)
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
2
19
www.schneider-electric.com
p Compact NS, Masterpact NT/NW
Metering, Measurement, Quality, Availability and Control Fixed device, front panel display FDM121 panel display ULP line terminations
TRV00121
(pack of 10) TRV00880
ULP device cord (optional)
1
Smart electrical control*
2
Device communication module (BCM ULP)*
3
Micrologic E/P/H* circuit breaker control unit
1
LV434195 (L = 0.35 m) LV434196 (L = 1.3 m) LV434197 (L = 3 m) 2
* For control with the circuit breaker for factory conversion (Rapsodie listing or control network)
3
Fixed device, remote view Communication interface (optional)
+24V 0V
ULP line terminations
Eth2 Eth1
TRV00210 (Modbus RS485 IFM) LV434010 (Ethernet IFE) LV434011 (Ethernet IFE + gateway function)
(pack of 10) TRV00880 R
1
Smart electrical control*
2
Device communication module (BCM ULP)*
3
Micrologic E/P/H* circuit breaker control unit
ULP device cord (optional) LV434195 (L = 0.35 m) LV434196 (L = 1.3 m) LV434197 (L = 3 m)
1
2
* For control with the circuit breaker for factory conversion (Rapsodie listing or control network)
3
20
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
www.schneider-electric.com
Compact NS, Masterpact NT/NW p
Metering, Measurement, Quality, Availability and Control Fixed device, front panel display and remote view ULP RJ45 cables (optional)
FDM121 panel display TRV00121
TRV00803 (L = 0.3 m, Quantity 10) TRV00806 (L = 0.6 m, Quantity 10) TRV00810 (L = 1 m, Quantity 5) TRV00820 (L = 2 m, Quantity 5) TRV00830 (L = 3 m, Quantity 5) TRV00850 (L = 5 m, Quantity 1)
Communication interface (optional) TRV00210 (Modbus RS485 IFM) LV434010 (Ethernet IFE) LV434011 (Ethernet IFE + gateway function)
+24V 0V
Eth2 Eth1
ULP device cord (optional) LV434195 (L = 0.35 m) LV434196 (L = 1.3 m) LV434197 (L = 3 m)
ULP line terminations
1
(pack of 10) TRV00880
1
Smart electrical control*
2
Device communication module (BCM ULP)*
3
Micrologic E/P/H* circuit breaker control unit
2
3 * For control with the circuit breaker for factory conversion (Rapsodie listing or control network)
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
21
www.schneider-electric.com
p Compact NS, Masterpact NT/NW
Metering, Measurement, Quality and Availability Drawout device, front panel display FDM121 panel display
Chassis communication module (I/O module)
TRV00121
LV434063
ULP device cord (optional)
ULP line terminations
LV434195 (L = 0.35 m) LV434196 (L = 1.3 m) LV434197 (L = 3 m)
(pack of 10) TRV00880
ULP RJ45 cables (optional) TRV00803 (L = 0.3 m, Quantity 10) TRV00806 (L = 0.6 m, Quantity 10) TRV00810 (L = 1 m, Quantity 5)
1
TRV00820 (L = 2 m, Quantity 5) TRV00830 (L = 3 m, Quantity 5) TRV00850 (L = 5 m, Quantity 1) 2
1
Chassis position contacts CE/CD/CT*
2
Device communication module (BCM ULP)*
3
Micrologic E/P/H* circuit breaker control unit Drawout device option*
* For control with the circuit breaker for factory conversion (Rapsodie listing or control network)
3
Drawout device, remote view Communication interface
+24V 0V
(optional)
Eth2 Eth1
TRV00210 (Modbus RS485 IFM) LV434010 (Ethernet IFE) LV434011 (Ethernet IFE + gateway function)
Chassis communication module (I/O module) LV434063
R
ULP device cord (optional) LV434195 (L = 0.35 m) LV434196 (L = 1.3 m) LV434197 (L = 3 m)
ULP line terminations (pack of 10) TRV00880
ULP RJ45 cables (optional)
1
TRV00803 (L = 0.3 m, Quantity 10) TRV00806 (L = 0.6 m, Quantity 10) TRV00810 (L = 1 m, Quantity 5)
1
Chassis position contacts CE/CD/CT*
2
Device communication module (BCM ULP)*
22
3
TRV00820 (L = 2 m, Quantity 5) TRV00830 (L = 3 m, Quantity 5) TRV00850 (L = 5 m, Quantity 1)
2
Micrologic E/P/H* circuit breaker control unit Drawout device option*
* For control with the circuit breaker for factory conversion (Rapsodie listing or control network)
3
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
www.schneider-electric.com
Compact NS, Masterpact NT/NW p
Metering, Measurement, Quality and Availability Drawout device, front panel display and remote view Communication interface (optional)
FDM121 panel display
Chassis communication module (I/O module)
TRV00210 (Modbus RS485 IFM) LV434010 (Ethernet IFE) LV434011 (Ethernet IFE + gateway function)
TRV00121
LV434063
+24V 0V
Eth2 Eth1
ULP RJ45 cables (optional) TRV00803 (L = 0.3 m, Quantity 10) TRV00806 (L = 0.6 m, Quantity 10) TRV00810 (L = 1 m, Quantity 5) TRV00820 (L = 2 m, Quantity 5) TRV00830 (L = 3 m, Quantity 5) TRV00850 (L = 5 m, Quantity 1)
R
ULP device cord (optional) LV434195 (L = 0.35 m) LV434196 (L = 1.3 m) LV434197 (L = 3 m)
ULP line terminations (pack of 10) TRV00880 1
1
Chassis position contacts CE/CD/CT*
2
Device communication module (BCM ULP)*
3
Micrologic E/P/H* circuit breaker control unit
2
Drawout device option* * For control with the circuit breaker for factory conversion (Rapsodie listing or control network)
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
3
23
www.schneider-electric.com
p Compact NS, Masterpact NT/NW
Metering, Measurement, Quality, Availability and Control Drawout device, front panel display FDM121 panel display
Chassis communication module (I/O module)
TRV00121
LV434063
ULP device cord (optional)
ULP line terminations
LV434195 (L = 0.35 m) LV434196 (L = 1.3 m) LV434197 (L = 3 m)
(pack of 10) TRV00880
ULP RJ45 cables (optional) TRV00803 (L = 0.3 m, Quantity 10) TRV00806 (L = 0.6 m, Quantity 10) TRV00810 (L = 1 m, Quantity 5)
1
Chassis position contacts CE/CD/CT*
2
Smart electrical control*
3
Device communication module (BCM ULP)*
TRV00820 (L = 2 m, Quantity 5) TRV00830 (L = 3 m, Quantity 5) TRV00850 (L = 5 m, Quantity 1)
4
1 2
Micrologic E/P/H* circuit breaker control unit Drawout device option*
3
* For control with the circuit breaker for factory conversion (Rapsodie listing or control network)
4
Drawout device, remote view Communication interface (optional)
+24V 0V
Chassis communication module (I/O module)
Eth2 Eth1
TRV00210 (Modbus RS485 IFM) LV434010 (Ethernet IFE) LV434011 (Ethernet IFE + gateway function)
LV434063
R
ULP device cord (optional) LV434195 (L = 0.35 m) LV434196 (L = 1.3 m) LV434197 (L = 3 m)
ULP line terminations (pack of 10) TRV00880
ULP RJ45 cables (optional) TRV00803 (L = 0.3 m, Quantity 10) TRV00806 (L = 0.6 m, Quantity 10) TRV00810 (L = 1 m, Quantity 5)
24
1
Chassis position contacts CE/CD/CT*
2
Smart electrical control*
3
Device communication module (BCM ULP)*
24
TRV00820 (L = 2 m, Quantity 5) TRV00830 (L = 3 m, Quantity 5) TRV00850 (L = 5 m, Quantity 1)
4
Micrologic E/P/H* circuit breaker control unit Drawout device option*
1 2 3
* For control with the circuit breaker for factory conversion (Rapsodie listing or control network)
4
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
www.schneider-electric.com
Compact NS, Masterpact NT/NW p
Metering, Measurement, Quality, Availability and Control Drawout device, front panel display and remote view FDM121 panel display
Chassis communication module (I/O module)
Communication interface (optional)
TRV00121
LV434063
TRV00210 (Modbus RS485 IFM) LV434010 (Ethernet IFE) LV434011 (Ethernet IFE + gateway function) +24V 0V
Eth2
ULP RJ45 cables (optional)
Eth1
TRV00803 (L = 0.3 m, Quantity 10) TRV00806 (L = 0.6 m, Quantity 10) TRV00810 (L = 1 m, Quantity 5) TRV00820 (L = 2 m, Quantity 5) TRV00830 (L = 3 m, Quantity 5) TRV00850 (L = 5 m, Quantity 1)
R
ULP device cord (optional) LV434195 (L = 0.35 m) LV434196 (L = 1.3 m) LV434197 (L = 3 m)
ULP line terminations (pack of 10) TRV00880 1 2 1 2 3 4
Chassis position contacts CE/CD/CT*
3
Smart electrical control* Device communication module (BCM ULP)* Micrologic E/P/H* circuit breaker control unit
4
Drawout device option* * For control with the circuit breaker for factory conversion (Rapsodie listing or control network) Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
25
25
www.schneider-electric.com
p Masterpact MTZ
Metering, Measurement, Quality, Availability and Control Drawout device, front panel display FDM128 panel display LV434128
NFC
ULP device cord (optional) LV434195 (L = 0.35 m) LV434196 (L = 1.3 m) LV434197 (L = 3 m)
1
1
Chassis position contacts CE/CD/CT*
2
Smart electrical control*
3
4
Micrologic X* circuit breaker control unit Drawout device option*
Device communication module (BCM ULP)*
2 3 * For control with the circuit breaker for factory conversion (Rapsodie listing or control network)
4
Drawout device, remote view
In 1600
Communication interface
NFC
FDM128 panel display
+24V 0V
Eth2 Eth1
LV434128
A
R
(optional) LV434010 (Ethernet IFE) LV434011 (Ethernet IFE + gateway function)
ULP device cord (optional) LV434195 (L = 0.35 m) LV434196 (L = 1.3 m) LV434197 (L = 3 m)
ULP RJ45 cables (optional) TRV00803 (L = 0.3 m, Quantity 10) TRV00806 (L = 0.6 m, Quantity 10) TRV00810 (L = 1 m, Quantity 5)
1
Chassis position contacts CE/CD/CT*
2
Smart electrical control*
3
Device communication module (BCM ULP)*
26
TRV00820 (L = 2 m, Quantity 5) TRV00830 (L = 3 m, Quantity 5) TRV00850 (L = 5 m, Quantity 1)
4
Micrologic X* circuit breaker control unit
1
2 3
Drawout device option* * For control with the circuit breaker for factory conversion (Rapsodie listing or control network)
4 In 1600
A
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
www.schneider-electric.com
Masterpact MTZ p
Metering, Measurement, Quality and Availability Drawout device, front panel display Chassis communication module (I/O module)
FDM128 panel display LV434128
LV434063
ULP device cord (optional)
ULP RJ45 cables (optional)
LV434195 (L = 0.35 m) LV434196 (L = 1.3 m) LV434197 (L = 3 m)
TRV00803 (L = 0.3 m, Quantity 10) TRV00806 (L = 0.6 m, Quantity 10) TRV00810 (L = 1 m, Quantity 5) TRV00820 (L = 2 m, Quantity 5) TRV00830 (L = 3 m, Quantity 5) TRV00850 (L = 5 m, Quantity 1)
1 2 3
Chassis position contacts CE/CD/CT* Device communication module (BCM ULP)* Micrologic X* circuit breaker control unit Drawout device option*
Communication interface LV851001 (eIFE embedded Ethernet interface for drawout Masterpact MTZ)
1
2
NFC
* For control with the circuit breaker for factory conversion (Rapsodie listing or control network)
3 In 1600
A
drawout device, remote view FDM128 panel display
Chassis communication module (I/O module)
+24V 0V
Eth2 Eth1
LV434128
LV434063
Communication interface (optional)
R
ULP device cord
LV434010 (Ethernet IFE) LV434011 (Ethernet IFE + gateway function)
(optional) LV434195 (L = 0.35 m) LV434196 (L = 1.3 m) LV434197 (L = 3 m)
ULP RJ45 cables (optional) See above
1 2 3
Chassis position contacts CE/CD/CT* Device communication module (BCM ULP)* Micrologic X* circuit breaker control unit Drawout device option* Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
2
1
NFC
3 * For control with the circuit breaker for factory conversion (Rapsodie listing or control network)
In 1600
A
27
www.schneider-electric.com
p Compact NS, Masterpact NT/NW, Masterpact MTZ
Multi-product architectures Architecture example 1
FDM128 multi-equipment panel display
1
LV434128
2
8
2 +24V 0V
RJ45 Ethernet cable VDIP184546010 (L = 1 m) VDIP184546030 (L = 3 m)
3
Eth2 Eth1
3 4 6
9
Coupling connector TRV00217
R
10
5
11
6
Masterpact MTZ or Masterpact NT/NW
7
Compact NSX
12
4
7
Ethernet interface
Circuit breaker control unit
NSX cable (optional)
LV434011 (IFE switchboard server)
Micrologic E, P or H for Masterpact NT/NW Micrologic X for Mastepact MTZ
LV434200 (L = 0.35 m) LV434201 (L = 1.3 m) LV434202 (L = 3 m)
5
Compact NS and Masterpact NT/NW cord LV434195 (L = 0.35 m) LV434196 (L = 1.3 m) LV434197 (L = 3 m)
6
Communication option BCM ULP (option for Masterpact NT, NW) ULP port (option for Masterpact MTZ)
28
10
11 8
Modbus RS485 interface TRV00210
9
ULP line terminations
BSCM module LV434205
12
Micrologic E circuit breaker control unit
(pack of 10) TRV00880 Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
www.schneider-electric.com
Compact NS, Masterpact NT/NW, Masterpact MTZ p
Energy and assets management Multi-product architectures
Architecture example
1
Com’X 510 Energy server
2
EBX510
14
ACT -100/ LK/10 ORK NETWUS STAT
COM
COM R
D1 D0
0V
RNET ETHE
2
US
STAT
8 7 POW
6
ER
5
230V 100- ER POW
4 ER
3
POW
2 1 ’X 200
Com
1
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
0V
I1
I2
Q 24V
AI2 24V 0V AI1
0V
+24V
8
Acti9 Smartlink SI B Ethernet wireless
7 6
5 4
3 2
1
13
A9XMEZA08
3 C +24VD CMD SDOF 0V
Reflex
11
12
14
1.2.3 iC60N -Mode Ready I. ON O. OFF eat Overh
auto
OF OFF
Coupling connector TRV00217
A
A
N P
4
Ethernet interface
8 +24V 0V
LV4340011 (IFE switchboard server) LV851001 ( eIFE for Masterpact MTZ)
3
5
Eth2 Eth1
4
Compact NS and Masterpact NT/NW cord
9 R
5
LV434195 (L = 0.35 m) LV434196 (L = 1.3 m) LV434197 (L = 3 m)
10
11 6 7
Compact NSX
Masterpact MTZ or Masterpact NT/NW 6
9
Communication option
ULP line terminations
BCM ULP (option for Masterpact NT, NW) ULP port (option for Masterpact MTZ)
TRV00880
7
(pack of 10)
10
Circuit breaker control unit
NSX cable (optional)
Micrologic E, P or H for Masterpact NT/NW Micrologic X for Mastepact MTZ
LV434200 (L = 0.35 m) LV434201 (L = 1.3 m) LV434202 (L = 3 m)
8
11
Modbus RS485 interface
BSCM module
TRV00210
LV434205
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
12
12
Micrologic E circuit breaker control unit 13
2 connectors Smartlink cable A9XCAS06 (L=100 mm) A9XCAM06 (L=160 mm) A9XCAH06 (L=450 mm) A9XCAL06 (L=870 mm)
14
Powertag power sensor for modular circuit breaker 29
www.schneider-electric.com
24 VDC power supply 24 VDC and supply unit consumption Compact NS, Masterpact NT/NW
Shared accessories BCM ULP module
FDM128 display
40 mA
285 mA
Micrologic E/P/H FDM121 display
100 mA
21 mA
I/O module 165 mA
Compact NSX BSCM module
+24V 0V
Eth2 Eth1
9 mA
IFE Ethernet interface 120 mA
R
Micrologic E 30 mA
24 V DC power supply unit
AD range
Phaseo range
Nominal current
1A
3A
Primary surge cat.
IV
II
24/30 V DC input
54440
/
48/60 V DC input
54441
/
100/125 V DC input
54442
/
110/130 V AC input
54443
200/240 V AC input
54444
380/415 V AC input
54445
30
RS485 IFM interface 21 mA
ABL8RPS24030
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
www.schneider-electric.com
24 VDC power supply calculation Single product calculation examples Compact NSX with RS485 interface and display
Compact NS with RS485 interface and display
Product
Consumption
Product
Consumption
FD121 display
21 mA
FD121 display
21 mA
RS485 IFM interface
21 mA
RS485 IFM interface
21 mA
BSCM module
9 mA
BCM ULP module
40 mA
Micrologic circuit breaker control unit
30 mA
Micrologic circuit breaker control unit
100 mA
Total
81 mA
Total
182 mA
Multi-product calculation example Compact NS with IFE Ethernet interface, 5 Compact NSX with RS485 IFM interfaces, 1 x FDM128 front panel display Product
Consumption
FDM128 display
285 mA
Qty 1
IFE Ethernet interface
120 mA
1
BCM ULP module
40 mA
1
Micrologic Compact NS
100 mA
1
RS485 IFM interface
21 mA
5
BSCM module
9 mA
+24V 0V
Eth2 Eth1
5
R
Micrologic Compact NSX 30 mA Total
Version : 1.0 - 22/09/2016
LV_ENLX_ACQ
5
845 mA
31
Schneider Electric Industries SAS 35, rue Joseph Monier CS 30323 92506 Rueil Malmaison Cedex France RCS Nanterre 954 503 439 Capital social 896 313 776 â‚Ź www.schneider-electric.comApril