Mitsubishi Electric modules and inverters. Just the right fit.
PHOTOVOLTAIC INVERTERS Inverter S Series
PV-S2600 2.6kW PV-S3200 3.2kW PV-S4200 4.2kW PV-S4600 4.6kW PV-S6000A 6.0kW Nominal Output
Nominal Output
Nominal Output
Nominal Output
Nominal Output
Data Logger
PV-LOG30
Energy Energ gy Performance Performa ance High efficiency of 97.5% (PV-S6000A), 97.5% (PV-S4600), 97.5% (PV-S4200) 96.8% (PV-S3200), 96.6% (PV-S2600) ■ Smooth Recovery Inverter Topology ■ Dual precision MPPT for each DC input* *PV-S4200 and PV-S4600 model ■
Reliability Original Or Ori ginal gin inal “generous “ge gener nerous ner ou design” ous de d sig ign” ” concept c cep con pt Cooling C li ffan control t l attuned ttt d to t temperature ■ Highly reliable aluminum housing developed from Mitsubishi Electric solar module technology ■ ■
Safety
Best B est P Performance er formance with L ong R el i a b i l i t y with Long Reliability
Perfectly sealed metal housing ensures non flammability (including the connection area) ■ “UL94V-0” Compliant resin material used ■
Easy Installation IP54, outside or inside installation possible ■ All-in-one style DC disconnector included, integrated into the case. Optional (internal) data logger available ■ Parallel installation in tight spaces ■ AC connection with various terminals (ring, pin, single wire) ■ DC connection with MC4 connector ■ Original configuration software ■
Maintenance ■
Easy maintenance of the cooling fan filter
User Friendly 255×160-pixel dot matrix LCD display, five-line screen ■ Optic easy operation switch ■
All models made in Japan
MITSUBISHI ELECTRIC PHOTOVOLTAIC INVERTERS INVERTER SPECIFICATIONS
Output
Energy performance
General specifications
Other specifications
PV-S4600 PV-S4200 PV-S6000A 6120Wp *1 5040Wp*1 7200Wp *1 5250W 4320W 6200W 700VDC 160VDC 270 – 600VDC *3 345*2 – 600VDC*3 240 – 600VDC*3 370– 600VDC *3 9ADC × 2 2 1 2 4600W 4200W 3200W 6000W 5100W 4200W 3200W 6000W 22.2A 18.3A 13.9A 26.1A < 5% at nominal AC power output 230VAC / 50Hz Single-phase approx.1 97.5% 97.5% 96.8% 97.5% 96.9% 96.8% 96.1% 96.7% 40W 0.5W 408 × 653 × 210 mm 24kg 45dB Transformer-less -25 – 50 degrees C *4 0 –100%Rh *5 Over-heating protection, ground fault protection IP54 DC-disconnector, cooling fan Dot matrix LCD (white LED backlight), 5-line screen Multi Contact locking connector (MC4) Terminal block RS-485 5 years (standard) / 10 years (option) PV-S3200 3840Wp *1 3310W
PV-S2600 3480Wp *1 3000W
Model name Recommended generator power Max. DC input power Max. DC input voltage Min. DC input voltage DC voltage range, MPPT Max. DC input current Number of MPPT Max. number of strings Nominal AC power Max. AC power Max. AC current Total harmonic distortion Nominal AC voltage / AC frequency AC connection Power factor Max. efficiency Euro efficiency Start feeding-in at Consumption stand-by / Nighttime Dimensions (W × H ×D ) Weight Noise level Insulating style Ambient temperature Ambient humidity Protection Protection class Equipment Display DC connector AC connector External communication
Input
300– 600VDC*3 1 1 2600W 2900W 12.6A
96.6% 95.8%
Warranty term
*1: Maximum values allowed. The configuration must take into account the values of irradiation and temperature. *2: Based on a grid voltage of 230V. May change depending on the grid voltage. *3: PV inverters can output the nominal AC power in this range. *4: The temperature range for maximum output power is between -25°C and 40°C. *5: Assuming no water condensation occuring.
EFFICIENCY
Vin=330V Vin=380V Vin=460V
80
95
90
Vin=330V Vin=380V Vin=460V
85
80 0 10 20 30 40 50 60 70 80 90 100 110 120 (%)
(%) 100
95
90
Vin=330V Vin=380V Vin=460V
85
80 0 10 20 30 40 50 60 70 80 90 100 110 120 (%)
Output Power Ratio
PV-S4600
95
90
85
Vin=330V Vin=380V Vin=460V
Output Power Ratio
95
90
Vin=330V Vin=380V Vin=460V
85
80
80 0 10 20 30 40 50 60 70 80 90 100 110 120 (%)
Output Power Ratio
PV-S6000A
(%) 100
Conversion Efficiency
90
PV-S4200
(%) 100
Conversion Efficiency
95
85
PV-S3200
(%) 100
Conversion Efficiency
PV-S2600
Conversion Efficiency
Conversion Efficiency
(%) 100
0 10 20 30 40 50 60 70 80 90 100 110 120 (%)
0 10 20 30 40 50 60 70 80 90 100 110 120 (%)
Output Power Ratio
Output Power Ratio
DATA LOGGER
DIMENSIONS Wind speed sensor
Irradiation sensor
408
210
Exhaust opening
653
Ambient Module temperature temperature
PV-S series
Up to 30 pieces
Unit : mm Ventilation opening
SPECIFICATIONS (DATA LOGGER) Ethernet
Analog
GSM/GPRS
Model name Interface
INTERNET (Dedicated server) PV-LOG30 Integrated into housing
Remote monitoring via the Internet https://wwwl5.mitsubishielectric.co.jp
PC
Mobile
Dimensions (WxHxD) Weight Power supply Power consumption
PV-LOG30 PV-Inverter (RS-485) “Sensor Input (RS-485, Irradiance, Temperature, Windspeed)” LAN (RJ-45) Modem (RS-232C or RS-485) Display data out (RS-485) Digital out x 2 (Open collector) Digital input x 4 277 x 46 x 134mm 460g DC13–15V 500mA Max