/L02_inst

Page 1

Copyright © MP Lighting All technical information in this document is subject to change.

1

Mount flange to electrical box so flange is setback 1/8” (3mm) up to flush from face of drywall.

2

Connect fixture wires to low voltage wiring (remote LED driver 350mA constant current).

T 604 708 1184 mplighting.com

3

Cut Ø1-5/8” (Ø41mm) hole in drywall to fit trim.

4

Apply plumber silicon to O-rings and insert fixture into flange. If fixture has an angle bracket, make sure beam is lined up in desired direction when inserting the trim.

Flange Screw

Wire Nut LED Trim

O-Ring

• Read all instructions. CAUTION

• WARNING: RISK OF FIRE OR ELECTRICAL SHOCK: Do not make or alter any openings in the compartment of wiring or electrical components during installation. Do not alter or add ballasts, or any other electrical components. • Installation and use of this fixture mounting assembly requires a person familiar with the construction and operation of luminaire electrical systems and the hazards involved, if not qualified, do not attempt installation.

3mm 1/8” face of drywall

Version 07-2009

• Turn off power before installation.

Parts

• Connect to 350mA constant current LED driver only.

• LED unit • Flange

• Do not spray water on fixture during cleaning. Avoid using detergents with hand softeners, anti-bacterial agents, glass cleaners or acrylic cleaning products. • KEEP THESE INSTALLATION INSTRUCTIONS.

Ø41mm Ø1-5/8

3mm 1/8”

Qty. 1 1

Maintenance Tools Plumbers silicon

included

Use a soft cloth to remove any fingerprints.

LED02 Installation Instructions