Top of concrete or final ground level

3mm 1/4”

LED04 Rough In Installation Instructions

Ø41mm Ø1-5/8”

Mounting tabs

• Read all instructions. CAUTION

• WARNING: RISK OF FIRE OR ELECTRICAL SHOCK: Do not make or alter any openings in the compartment of wiring or electrical components during installation. Do not alter or add ballasts, or any other electrical components.

Optional mounting hardware

• Installation and use of this fixture mounting assembly requires a person familiar with the construction and operation of luminaire electrical systems and the hazards involved, if not qualified, do not attempt installation. • Turn off power before installation. • Connect to 350mA constant current LED driver only. • Avoid using detergents with hand softeners, anti-bacterial agents, glass cleaners or acrylic cleaning products.

1 2 3

Remove flange, install wiring and conduit. Refer to applicable wiring diagram.

Plastic Cap

Replace flange and insert plastic cap into electrical box. Ensure all gaskets are in place and knockouts are plugged. DO NOT LET CONCRETE ENTER BOX.

Screws

Position electrical box so flange is within 1/4” (3mm) from top of poured concrete. Use mounting tabs or optional mounting hardware. Ensure flange is level.

Washers

Mounting Flange

Foam Sealing Gasket

Rough In Parts

Qty.

• Plastic cap 1 • Mounting screws 4 • Washers 4 • Mounting flange with level 1 • Foam sealing gasket 1 • Splice box 1 • Mounting hardware optional

T 604 708 1184 mplighting.com

Splice Box

Copyright © MP Lighting All technical information in this document is subject to change.

• KEEP THESE INSTALLATION INSTRUCTIONS.

Version 07-2009


LED04 LED Trim Installation Instructions

1

After concrete has cured, crack concrete above flange and remove plastic cap using a corkscrew or similar tool.

LED Trim

O-Ring

3

Connect fixture leads to box wiring using supplied waterproof wire nuts.

Waterproof Wire Nuts

Apply a smear of plumbers silicone to o-rings. With a twisting motion insert trim in flange. If fixture has an angle bracket, make sure beam is lined up in desired direction when inserting the trim.

Trim Parts • LED trim • Waterproof wire nuts • Plumbers silicon

Qty. 1 2 included

Tools • Corkscrew

not included

Maintenance Clean using a soft cloth.

• Read all instructions. CAUTION

• WARNING: RISK OF FIRE OR ELECTRICAL SHOCK: Do not make or alter any openings in the compartment of wiring or electrical components during installation. Do not alter or add ballasts, or any other electrical components. • Installation and use of this fixture mounting assembly requires a person familiar with the construction and operation of luminaire electrical systems and the hazards involved, if not qualified, do not attempt installation. • Turn off power before installation. • Connect to 350mA constant current LED driver only. • Avoid using detergents with hand softeners, anti-bacterial agents, glass cleaners or acrylic cleaning products. • KEEP THESE INSTALLATION INSTRUCTIONS.

T 604 708 1184 mplighting.com

Copyright © MP Lighting All technical information in this document is subject to change.

2

Version 07-2009


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.