Top of concrete or final ground level
9.5mm 3/8”
LED05
Ø70mm Ø2-3/4”
Rough In Installation Instructions
• Read all instructions. CAUTION
• WARNING: RISK OF FIRE OR ELECTRICAL SHOCK: Do not make or alter any openings in the compartment of wiring or electrical components during installation. Do not alter or add ballasts, or any other electrical components.
Mounting tabs
• Installation and use of this fixture mounting assembly requires a person familiar with the construction and operation of luminaire electrical systems and the hazards involved, if not qualified, do not attempt installation.
Optional mounting hardware
• Turn off power before installation. • Connect to 350mA constant current LED driver only. • Avoid using detergents with hand softeners, anti-bacterial agents, glass cleaners or acrylic cleaning products. • KEEP THESE INSTALLATION INSTRUCTIONS.
Plastic Cap
2
Replace flange and insert plastic cap into flange. Ensure all gaskets are in place and knockouts are plugged. DO NOT LET CONCRETE ENTER BOX.
Screws Washers
3
Position electrical box so flange is within 3/8” (9.5mm) from top of poured concrete. Use mounting tabs or optional mounting hardware. Ensure flange is level.
Rough In Parts
Qty.
• Plastic cap 1 • Mounting screws 4 • Washers 4 • Mounting flange with level 1 • Foam sealing gasket 1 • Splice box 1 • Mounting hardware optional
Mounting Flange
Foam Sealing Gasket
Splice Box
1/2” NPT (National Pipe Thread)
T 604 708 1184 mplighting.com
Copyright © MP Lighting All technical information in this document is subject to change.
1
Remove flange, install wiring and conduit (use 1/2” NPT). Refer to applicable wiring diagram.
Version 12-2009
LED05 LED Trim Installation Instructions
2 3
After concrete has cured, crack concrete above flange and remove plastic cap using a corkscrew or similar tool.
LED Trim
O-Ring Connect fixture leads to box wiring using supplied waterproof wire nuts. Waterproof Wire Nuts
Apply a smear of plumbers silicone to o-rings. With a twisting motion insert trim in flange. If fixture has an angle bracket, make sure beam is lined up in desired direction when inserting the trim.
Trim Parts • LED trim • Waterproof wire nuts • Plumbers silicon
Qty. 1 2 included
Tools • Corkscrew
not included
Maintenance Clean using a soft cloth.
• Read all instructions. CAUTION
• WARNING: RISK OF FIRE OR ELECTRICAL SHOCK: Do not make or alter any openings in the compartment of wiring or electrical components during installation. Do not alter or add ballasts, or any other electrical components. • Installation and use of this fixture mounting assembly requires a person familiar with the construction and operation of luminaire electrical systems and the hazards involved, if not qualified, do not attempt installation. • Turn off power before installation. • Connect to 350mA constant current LED driver only. • Avoid using detergents with hand softeners, anti-bacterial agents, glass cleaners or acrylic cleaning products. • KEEP THESE INSTALLATION INSTRUCTIONS.
T 604 708 1184 mplighting.com
Copyright © MP Lighting All technical information in this document is subject to change.
1
Version 12-2009