Top of concrete or final ground level

9.5mm 3/8”

LED05

Ø70mm Ø2-3/4”

Rough In Installation Instructions

• Read all instructions. CAUTION

• WARNING: RISK OF FIRE OR ELECTRICAL SHOCK: Do not make or alter any openings in the compartment of wiring or electrical components during installation. Do not alter or add ballasts, or any other electrical components.

Mounting tabs

• Installation and use of this fixture mounting assembly requires a person familiar with the construction and operation of luminaire electrical systems and the hazards involved, if not qualified, do not attempt installation.

Optional mounting hardware

• Turn off power before installation. • Connect to 350mA constant current LED driver only. • Avoid using detergents with hand softeners, anti-bacterial agents, glass cleaners or acrylic cleaning products. • KEEP THESE INSTALLATION INSTRUCTIONS.

Plastic Cap

2

Replace flange and insert plastic cap into flange. Ensure all gaskets are in place and knockouts are plugged. DO NOT LET CONCRETE ENTER BOX.

Screws Washers

3

Position electrical box so flange is within 3/8” (9.5mm) from top of poured concrete. Use mounting tabs or optional mounting hardware. Ensure flange is level.

Rough In Parts

Qty.

• Plastic cap 1 • Mounting screws 4 • Washers 4 • Mounting flange with level 1 • Foam sealing gasket 1 • Splice box 1 • Mounting hardware optional

Mounting Flange

Foam Sealing Gasket

Splice Box

1/2” NPT (National Pipe Thread)

T 604 708 1184 mplighting.com

Copyright © MP Lighting All technical information in this document is subject to change.

1

Remove flange, install wiring and conduit (use 1/2” NPT). Refer to applicable wiring diagram.

Version 12-2009


LED05 LED Trim Installation Instructions

2 3

After concrete has cured, crack concrete above flange and remove plastic cap using a corkscrew or similar tool.

LED Trim

O-Ring Connect fixture leads to box wiring using supplied waterproof wire nuts. Waterproof Wire Nuts

Apply a smear of plumbers silicone to o-rings. With a twisting motion insert trim in flange. If fixture has an angle bracket, make sure beam is lined up in desired direction when inserting the trim.

Trim Parts • LED trim • Waterproof wire nuts • Plumbers silicon

Qty. 1 2 included

Tools • Corkscrew

not included

Maintenance Clean using a soft cloth.

• Read all instructions. CAUTION

• WARNING: RISK OF FIRE OR ELECTRICAL SHOCK: Do not make or alter any openings in the compartment of wiring or electrical components during installation. Do not alter or add ballasts, or any other electrical components. • Installation and use of this fixture mounting assembly requires a person familiar with the construction and operation of luminaire electrical systems and the hazards involved, if not qualified, do not attempt installation. • Turn off power before installation. • Connect to 350mA constant current LED driver only. • Avoid using detergents with hand softeners, anti-bacterial agents, glass cleaners or acrylic cleaning products. • KEEP THESE INSTALLATION INSTRUCTIONS.

T 604 708 1184 mplighting.com

Copyright © MP Lighting All technical information in this document is subject to change.