Flush with top of concrete or final ground level
LED06 Rough In
Ø22 mm Ø7/8”
Installation Instructions
• Read all instructions. CAUTION
• WARNING: RISK OF FIRE OR ELECTRICAL SHOCK: Do not make or alter any openings in the compartment of wiring or electrical components during installation. Do not alter or add ballasts, or any other electrical components. • Installation and use of this fixture mounting assembly requires a person familiar with the construction and operation of luminaire electrical systems and the hazards involved, if not qualified, do not attempt installation. • Turn off power before installation. Mounting tabs
• Connect to 6VDC constant voltage LED driver only. • Avoid using detergents with hand softeners, anti-bacterial agents, glass cleaners or acrylic cleaning products. • KEEP THESE INSTALLATION INSTRUCTIONS.
2
3
Pull wire connector up through flange. Replace gasket and cover plate then place plastic insert and wire connector into flange. Ensure all gaskets are in place and knockouts are plugged. DO NOT LET CONCRETE ENTER BOX.
Flange
Screws
Cover Plate
Position electrical box, using mounting tabs, so flange is flush with the face of poured concrete. Gasket
Rough In Parts • Plastic insert • Mounting screws • Wire connector partB with leads • Cover plate with flange • Gasket • Waterproof wire nuts • Splice box
Qty. 1 2 1 1 1 2 1
Waterproof Wire Nuts
Splice Box
T 604 708 1184 mplighting.com
Wire Connector PartB
Copyright © MP Lighting All technical information in this document is subject to change.
1
Plastic Insert
Remove cover plate, install wiring and conduit. Refer to applicable wiring diagram.
Version 07-2009
LED06 1
2 3
O-Ring
After concrete has cured, crack concrete above flange and remove plastic insert using a corkscrew or similar tool. Pull wire connector partB out of flange.
LED Trim Installation Instructions
LED Trim
Connect trim leads from wire connector partA to partB by pushing until it click in place. Apply a smear of plumbers silicone to o-ring. With a twisting motion insert trim in flange.
Wire Connector PartA
Wire Connector PartB
Trim Parts • LED trim • Wire connector partA • Plumbers silicon
Qty. 1 1 included
Maintenance Clean using a soft cloth.
• Read all instructions. CAUTION
• WARNING: RISK OF FIRE OR ELECTRICAL SHOCK: Do not make or alter any openings in the compartment of wiring or electrical components during installation. Do not alter or add ballasts, or any other electrical components. • Installation and use of this fixture mounting assembly requires a person familiar with the construction and operation of luminaire electrical systems and the hazards involved, if not qualified, do not attempt installation. • Turn off power before installation. • Connect to 6VDC constant voltage LED driver only. • Avoid using detergents with hand softeners, anti-bacterial agents, glass cleaners or acrylic cleaning products. • KEEP THESE INSTALLATION INSTRUCTIONS.