/L06_inst

Page 1

Flush with top of concrete or final ground level

LED06 Rough In

Ø22 mm Ø7/8”

Installation Instructions

• Read all instructions. CAUTION

• WARNING: RISK OF FIRE OR ELECTRICAL SHOCK: Do not make or alter any openings in the compartment of wiring or electrical components during installation. Do not alter or add ballasts, or any other electrical components. • Installation and use of this fixture mounting assembly requires a person familiar with the construction and operation of luminaire electrical systems and the hazards involved, if not qualified, do not attempt installation. • Turn off power before installation. Mounting tabs

• Connect to 6VDC constant voltage LED driver only. • Avoid using detergents with hand softeners, anti-bacterial agents, glass cleaners or acrylic cleaning products. • KEEP THESE INSTALLATION INSTRUCTIONS.

2

3

Pull wire connector up through flange. Replace gasket and cover plate then place plastic insert and wire connector into flange. Ensure all gaskets are in place and knockouts are plugged. DO NOT LET CONCRETE ENTER BOX.

Flange

Screws

Cover Plate

Position electrical box, using mounting tabs, so flange is flush with the face of poured concrete. Gasket

Rough In Parts • Plastic insert • Mounting screws • Wire connector partB with leads • Cover plate with flange • Gasket • Waterproof wire nuts • Splice box

Qty. 1 2 1 1 1 2 1

Waterproof Wire Nuts

Splice Box

T 604 708 1184 mplighting.com

Wire Connector PartB

Copyright © MP Lighting All technical information in this document is subject to change.

1

Plastic Insert

Remove cover plate, install wiring and conduit. Refer to applicable wiring diagram.

Version 07-2009


LED06 1

2 3

O-Ring

After concrete has cured, crack concrete above flange and remove plastic insert using a corkscrew or similar tool. Pull wire connector partB out of flange.

LED Trim Installation Instructions

LED Trim

Connect trim leads from wire connector partA to partB by pushing until it click in place. Apply a smear of plumbers silicone to o-ring. With a twisting motion insert trim in flange.

Wire Connector PartA

Wire Connector PartB

Trim Parts • LED trim • Wire connector partA • Plumbers silicon

Qty. 1 1 included

Maintenance Clean using a soft cloth.

• Read all instructions. CAUTION

• WARNING: RISK OF FIRE OR ELECTRICAL SHOCK: Do not make or alter any openings in the compartment of wiring or electrical components during installation. Do not alter or add ballasts, or any other electrical components. • Installation and use of this fixture mounting assembly requires a person familiar with the construction and operation of luminaire electrical systems and the hazards involved, if not qualified, do not attempt installation. • Turn off power before installation. • Connect to 6VDC constant voltage LED driver only. • Avoid using detergents with hand softeners, anti-bacterial agents, glass cleaners or acrylic cleaning products. • KEEP THESE INSTALLATION INSTRUCTIONS.

T 604 708 1184 mplighting.com

Copyright © MP Lighting All technical information in this document is subject to change.