Linear Strip Light
L101A
SPEC SHEET Application: Indoor linear cove, wall slot, shelf and cabinet illumination. Electrical: 4 x 1W or 6 x 1W LEDs/Ft. Powered by remote driver (not included). Input Current: S2 = 350mA/foot or S3 = 230mA/foot Input Voltage: 24V DC Power Consumption: S2 = 6W/foot or S3 = 4W/foot Recommended Driver: TLDAV100W24. Dimmable with 0~10V dimming controller (TLC010i, not included). Consult factory. Weight: 0.56lbs (0.25kg)/foot. Material: Aluminum, polycarbonate, RoHS compliant. Mounting: Surface mount. Includes aluminum mounting channel with wiring compartment. Comes with 3' (914mm) wire lead.
S (LED spacing)
Approval: Dry locations. Approved to US and Canadian standards by CSA. 50
1-1/4” 32mm
Type: 1/8” 3mm
Project:
L (circuit board length)
Modified: flat frosted lens
clear convex lens
Quantity:
0°
Notes: 1” 25mm
45 .
1-3/8” 35mm
Code
Mount
L101
A A = 45° angle
Length (L)
Spacing (S)
1-1/4” 32mm
Color
Beam
-
Lens
120 1 = 1’ (305mm) 2 = 2’ (610mm) 3 = 3’ (915mm) 4 = 4’ (1219mm) 8 = 8’ (2438mm) X = custom
S2 = 2” (51mm) S3 = 3” (76mm) between LEDs
’
Note: S2 = 12' (3658mm) max. S3 = 18' (5486mm) max.
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
W27S W30S W35S W41S W20H W30H
= 2700K, std CRI = 3000K, std CRI = 3500K, std CRI = 4100K, std CRI = 2000K, high CRI* = 3000K, high CRI
120 = 120°
Finish -
T = flat clear F = flat frosted C = clear convex
MA MA = matte clear anodized
*W20H has consistent binning that falls within 1.5 MacAdam ellipse.
Copyright © MP Lighting. All technical information in this document is subject to change.
02-2011
Linear Strip Light
L101A
SPEC SHEET Photometric Data
L101 4’ Length S2 Spacing 120°, Frosted 2000K High 869 lm
Polar Candela Distribution
Illuminance at a Distance
180° -90°
Center Beam FC
90°
-45°
approx. 380 cd max.
45°
Beam Width
1.5’
69.27
5.0’
3.0’
17.32
10.0’
4.7’ 9.4’
4.5’
7.70
15.0’
14.1’
6.0’
4.33
20.0’
18.8’
7.5’
2.77
25.0’
23.5’
0° Spread: 118.1°
9.0’
1.92
30.0’
28.3’
90° Spread: 115.0°
0°
Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%
RCC %: RW %: 70 RCR: 0 .64 1 .58 2 .53 3 .48 4 .44 5 .41 6 .37 7 .35 8 .32 9 .30 .28 10
L101 4’ Length S3 Spacing 120°, Frosted 2000K High 579 lm
80
50 .64 .56 .49 .43 .38 .34 .30 .27 .25 .23 .21
30 .64 .54 .45 .38 .33 .29 .25 .23 .20 .18 .17
70
0 .64 .51 .42 .35 .29 .25 .22 .19 .15 .15 .14
70 .62 .57 .52 .47 .43 .39 .36 .34 .31 .29 .27
50 .62 .55 .48 .42 .37 .33 .30 .27 .25 .22 .21
50
30 .62 .52 .44 .38 .33 .28 .25 .22 .20 .18 .17
Polar Candela Distribution
0 .53 .45 .38 .32 .28 .24 .21 .19 .17 .15 .14
50 .59 .52 .46 .40 .36 .32 .29 .26 .24 .22 .20
30
30 .50 .51 .43 .37 .32 .28 .25 .22 .20 .18 .16
20 .59 .49 .40 .34 .29 .25 .22 .19 .17 .15 .14
50 .57 .50 .44 .40 .35 .31 .28 .25 .23 .21 .20
10
30 .57 .49 .41 .37 .31 .27 .24 .22 .20 .18 .16
20 .57 .47 .39 .33 .29 .25 .22 .19 .17 .15 .14
50 .55 .48 .42 .37 .33 .30 .27 .24 .22 .21 .19
0
30 .55 .47 .40 .35 .30 .27 .24 .21 .19 .17 .16
20 .55 .46 .38 .33 .28 .24 .21 .19 .17 .15 .14
0 .53 .45 .37 .31 .27 .23 .20 .18 .16 .14 .13
Illuminance at a Distance
180° -90°
Center Beam FC
90°
-45°
approx. 250 cd max.
45°
Beam Width
1.5’
46.30
5.0’
3.0’
11.58
10.0’
4.7’ 9.4’
4.5’
5.14
15.0’
14.2’
6.0’
2.89
20.0’
18.9’
7.5’
1.85
25.0’
23.6’
0° Spread: 118.1°
9.0’
1.29
30.0’
28.3’
90° Spread: 115.1°
0°
Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%
RCC %: RW %: 70 RCR: 0 .96 1 .88 2 .80 3 .73 4 .66 5 .61 6 .56 7 .52 8 .48 9 .45 10 .42
80
50 .96 .84 .73 .64 .57 .51 .45 .41 .37 .34 .32
30 .96 .80 .68 .57 .50 .43 .38 .34 .28 .28 .25
70
0 .96 .77 .63 .52 .44 .38 .33 .29 .23 .23 .21
70 .94 .85 .78 .71 .64 .59 .55 .51 .47 .44 .41
50 .94 .82 .71 .63 .56 .50 .45 .40 .37 .34 .31
50
30 .94 .79 .66 .57 .49 .43 .38 .34 .30 .27 .25
0 .94 .68 .57 .48 .42 .36 .32 .28 .25 .23 .20
50 .89 .78 .69 .60 .53 .48 .43 .39 .36 .33 .30
30
30 .89 .76 .64 .55 .48 .42 .37 .33 .30 .27 .25
20 .89 .74 .61 .51 .43 .37 .32 .29 .25 .23 .21
50 .86 .75 .66 .58 .52 .46 .42 .38 .35 .32 .30
10
30 .86 .73 .62 .54 .47 .41 .36 .32 .29 .27 .24
20 .86 .71 .59 .50 .42 .37 .32 .28 .25 .23 .21
50 .82 .72 .63 .56 .50 .45 .40 .37 .34 .31 .29
0
30 .82 .71 .60 .52 .45 .40 .36 .32 .29 .26 .24
20 .82 .69 .58 .49 .42 .36 .32 .28 .25 .23 .21
0 .80 .67 .56 .47 .40 .35 .30 .27 .24 .21 .19
Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
Copyright © MP Lighting. All technical information in this document is subject to change.
02-2011
Linear Strip Light
L101A
SPEC SHEET Photometric Data
L101 4’ Length S2 Spacing 120°, Frosted 3000K Std 2040 lm
Polar Candela Distribution
Illuminance at a Distance
180° -90°
Center Beam FC
90°
-45°
approx. 380 cd max.
45°
Beam Width
1.5’
169.70
4.8’
3.0’
42.42
9.5’
4.4’ 8.9’
4.5’
18.86
14.3’
13.3’
6.0’
10.61
19.0’
17.7’
7.5’
6.79
23.8’
22.1’
0° Spread: 115.5°
9.0’
4.71
28.5’
26.6’
90° Spread: 111.7°
0°
Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%
RCC %: RW %: 70 RCR: 0 .64 1 .58 2 .53 3 .48 4 .44 5 .41 6 .38 7 .35 8 .32 9 .30 10 .28
L101 4’ Length S3 Spacing 120°, Frosted 3000K Std 1360 lm
80
50 .64 .56 .49 .43 .38 .34 .30 .28 .25 .23 .21
30 .64 .54 .45 .38 .33 .29 .26 .23 .21 .19 .17
70
0 .64 .52 .42 .35 .30 .25 .22 .20 .17 .16 .14
70 .62 .57 .52 .47 .43 .40 .37 .34 .32 .29 .28
50 .62 .55 .48 .42 .37 .33 .30 .27 .25 .23 .21
50
30 .62 .53 .44 .38 .33 .29 .25 .23 .20 .18 .17
Polar Candela Distribution
0 .53 .45 .38 .32 .28 .24 .21 .19 .17 .15 .14
50 .60 .52 .46 .40 .36 .32 .29 .26 .24 .22 .20
30
30 .60 .51 .43 .37 .32 .28 .25 .22 .20 .18 .17
20 .60 .49 .41 .34 .29 .25 .22 .19 .17 .16 .14
50 .57 .50 .44 .39 .35 .31 .28 .25 .23 .21 .20
10
30 .57 .49 .42 .36 .31 .27 .24 .22 .20 .18 .16
20 .57 .48 .40 .33 .29 .25 .22 .19 .17 .15 .14
50 .55 .48 .42 .37 .33 .30 .27 .25 .23 .21 .19
0
30 .55 .47 .40 .35 .30 .27 .24 .21 .19 .18 .16
20 .55 .46 .39 .33 .28 .24 .21 .19 .17 .15 .14
0 .53 .45 .37 .32 .27 .23 .20 .18 .16 .14 .13
Illuminance at a Distance
180° -90°
Center Beam FC
90°
-45°
approx. 250 cd max.
45°
Beam Width
1.5’
108.97
4.7’
3.0’
27.24
9.3’
4.5’ 9.0’
4.5’
12.11
14.0’
13.5’
6.0’
6.81
18.7’
18.0’
7.5’
4.36
23.4’
22.5’
0° Spread: 114.6°
9.0’
3.03
28.0’
27.0’
90° Spread: 112.6°
0°
Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%
RCC %: RW %: 70 RCR: 0 .61 1 .56 2 .51 3 .47 4 .43 5 .39 6 .36 7 .33 8 .31 9 .29 10 .27
80
50 .61 .54 .47 .41 .36 .33 .29 .26 .24 .22 .20
30 .61 .52 .43 .37 .32 .28 .25 .22 .20 .18 .16
70
0 .61 .50 .40 .34 .28 .24 .21 .19 .17 .15 .14
70 .60 .55 .50 .45 .41 .38 .35 .33 .30 .28 .27
50 .60 .52 .46 .40 .36 .32 .29 .26 .24 .22 .20
50
30 .60 .51 .43 .36 .31 .28 .24 .22 .20 .18 .16
0 .51 .44 .37 .31 .27 .23 .20 .18 .16 .15 .13
50 .57 .50 .44 .39 .34 .31 .28 .25 .23 .21 .20
30
30 .57 .49 .41 .35 .31 .27 .24 .21 .19 .18 .16
20 .57 .47 .39 .33 .28 .24 .21 .19 .17 .15 .14
50 .55 .48 .42 .37 .33 .30 .27 .24 .22 .21 .19
10
30 .55 .47 .40 .34 .30 .26 .23 .21 .19 .17 .16
20 .55 .46 .38 .32 .27 .24 .21 .18 .16 .15 .13
50 .52 .46 .41 .36 .32 .29 .26 .24 .22 .20 .19
0
30 .52 .45 .39 .34 .29 .26 .23 .21 .19 .17 .16
20 .52 .44 .37 .31 .27 .23 .21 .18 .16 .15 .13
0 .51 .43 .36 .30 .26 .22 .20 .17 .15 .14 .12
Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
Copyright © MP Lighting. All technical information in this document is subject to change.
02-2011