Linear Strip Light
L103 suspension set mounting SPEC SHEET
Application: Suspended linear strip light Electrical: 4 x 1W or 6 x 1W LEDs/Ft. Powered by remote driver (not included). Input Current: S2 = 350mA/foot or S3 = 230mA/foot Input Voltage: 24V DC Power Consumption: S2 = 6W/foot or S3 = 4W/foot Recommended Driver: TLDAV100W24. Dimmable with 0~10V dimming controller (TLC010i, not included). Consult factory.
S (LED spacing)
Weight: 0.90lb (0.41kg)/foot. 1-1/4” 32mm
Ø1” 25mm
Material: Aluminum and polycarbonate. RoHS compliant.
1/8” 3mm
Mounting: Mounts directly to surface by rod or cable suspension sets (sold separately). Comes with 6' (1829mm) wire lead. Power feed is 12" (305mm) from the end.
Ø1” Ø25mm
L (circuit board length)
Approval: Dry locations. Approved to US and Canadian standards by CSA. Ø1” Ø25mm
Ø1” Ø25mm
50
Notes: Recommended suspension points should be 4’ (1219) on center max.
Type: drop
Project:
drop
Modified:
drop
drop
Quantity: Notes: 1-7/8” 48mm
flat frosted lens
convex clear lens
Code 1:3
L103
Length (L)
Spacing (S)
Color
W27S W30S W35S W41S W20H W30H
S2 = 2” (51mm) S3 = 3” (76mm) between LEDs
Note: S2 = 12' (3658mm) max. per 100W24V driver S3 = 18' (5486mm) max. per 100W24V driver Code
Drop
SDF060
-
Cable Suspension 2-1/8” 54mm
Beam 1:3
4 = 4’ (1219mm) 8 = 8’ (2438mm) X = custom
drop
1-7/8” 48mm
2-1/8” 54mm
drop
24 = 24" (610mm) X = custom
= 2700K, std CRI = 3000K, std CRI = 3500K, std CRI = 4100K, std CRI = 2000K, high CRI* = 3000K, high CRI
Finish -
1-7/8” 48mm
Rod Suspension
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
2-1/8” 54mm
MA
T = flat clear F = flat frosted C = convex clear
MA = matte clear anodized
*W20H has consistent binning that falls within 1.5 MacAdam ellipse.
SDF061
MC = matte chrome
Finish -
120 = 120° beam
Codedrop
MC
Lens
120
Drop
option drop
12 = 12" (305mm) X = custom 1-7/8” 48mm
Finish -
S1 = swivel 1
MC MC = matte chrome
Maximum offset angle: ±30˚
Copyright © MP Lighting. All technical information in this document is subject to change.
02-2011
Linear Strip Light
L103 suspension set mounting SPEC SHEET Photometric Data
L103 4’ Length S2 Spacing 120°, Frosted 2000K High 869 lm
Polar Candela Distribution
Illuminance at a Distance
180° -90°
Center Beam FC
90°
-45°
approx. 380 cd max.
45°
Beam Width
1.5’
69.27
5.0’
3.0’
17.32
10.0’
4.7’ 9.4’
4.5’
7.70
15.0’
14.1’
6.0’
4.33
20.0’
18.8’
7.5’
2.77
25.0’
23.5’
0° Spread: 118.1°
9.0’
1.92
30.0’
28.3’
90° Spread: 115.0°
0°
Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%
RCC %: RW %: 70 RCR: 0 .64 1 .58 2 .53 3 .48 4 .44 5 .41 6 .37 7 .35 8 .32 9 .30 10 .28
L103 4’ Length S3 Spacing 120°, Frosted 2000K High 579 lm
80
50 .64 .56 .49 .43 .38 .34 .30 .27 .25 .23 .21
30 .64 .54 .45 .38 .33 .29 .25 .23 .20 .18 .17
70
0 .64 .51 .42 .35 .29 .25 .22 .19 .15 .15 .14
70 .62 .57 .52 .47 .43 .39 .36 .34 .31 .29 .27
50 .62 .55 .48 .42 .37 .33 .30 .27 .25 .22 .21
50
30 .62 .52 .44 .38 .33 .28 .25 .22 .20 .18 .17
Polar Candela Distribution
0 .53 .45 .38 .32 .28 .24 .21 .19 .17 .15 .14
50 .59 .52 .46 .40 .36 .32 .29 .26 .24 .22 .20
30
30 .50 .51 .43 .37 .32 .28 .25 .22 .20 .18 .16
20 .59 .49 .40 .34 .29 .25 .22 .19 .17 .15 .14
50 .57 .50 .44 .40 .35 .31 .28 .25 .23 .21 .20
10
30 .57 .49 .41 .37 .31 .27 .24 .22 .20 .18 .16
20 .57 .47 .39 .33 .29 .25 .22 .19 .17 .15 .14
50 .55 .48 .42 .37 .33 .30 .27 .24 .22 .21 .19
0
30 .55 .47 .40 .35 .30 .27 .24 .21 .19 .17 .16
20 .55 .46 .38 .33 .28 .24 .21 .19 .17 .15 .14
0 .53 .45 .37 .31 .27 .23 .20 .18 .16 .14 .13
Illuminance at a Distance
180° -90°
Center Beam FC
90°
-45°
approx. 250 cd max.
45°
Beam Width
1.5’
46.30
5.0’
3.0’
11.58
10.0’
4.7’ 9.4’
4.5’
5.14
15.0’
14.2’
6.0’
2.89
20.0’
18.9’
7.5’
1.85
25.0’
23.6’
0° Spread: 118.1°
9.0’
1.29
30.0’
28.3’
90° Spread: 115.1°
0°
Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%
RCC %: RW %: 70 RCR: 0 .96 1 .88 2 .80 3 .73 4 .66 5 .61 6 .56 7 .52 8 .48 9 .45 10 .42
80
50 .96 .84 .73 .64 .57 .51 .45 .41 .37 .34 .32
30 .96 .80 .68 .57 .50 .43 .38 .34 .28 .28 .25
70
0 .96 .77 .63 .52 .44 .38 .33 .29 .23 .23 .21
70 .94 .85 .78 .71 .64 .59 .55 .51 .47 .44 .41
50 .94 .82 .71 .63 .56 .50 .45 .40 .37 .34 .31
50
30 .94 .79 .66 .57 .49 .43 .38 .34 .30 .27 .25
0 .94 .68 .57 .48 .42 .36 .32 .28 .25 .23 .20
50 .89 .78 .69 .60 .53 .48 .43 .39 .36 .33 .30
30
30 .89 .76 .64 .55 .48 .42 .37 .33 .30 .27 .25
20 .89 .74 .61 .51 .43 .37 .32 .29 .25 .23 .21
50 .86 .75 .66 .58 .52 .46 .42 .38 .35 .32 .30
10
30 .86 .73 .62 .54 .47 .41 .36 .32 .29 .27 .24
20 .86 .71 .59 .50 .42 .37 .32 .28 .25 .23 .21
50 .82 .72 .63 .56 .50 .45 .40 .37 .34 .31 .29
0
30 .82 .71 .60 .52 .45 .40 .36 .32 .29 .26 .24
20 .82 .69 .58 .49 .42 .36 .32 .28 .25 .23 .21
0 .80 .67 .56 .47 .40 .35 .30 .27 .24 .21 .19
Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
Copyright © MP Lighting. All technical information in this document is subject to change.
02-2011
Linear Strip Light
L103 suspension set mounting SPEC SHEET Photometric Data
L103 4’ Length S2 Spacing 120°, Frosted 3000K Std 2040 lm
Polar Candela Distribution
Illuminance at a Distance
180° -90°
Center Beam FC
90°
-45°
approx. 380 cd max.
45°
Beam Width
1.5’
169.70
4.8’
3.0’
42.42
9.5’
4.4’ 8.9’
4.5’
18.86
14.3’
13.3’
6.0’
10.61
19.0’
17.7’
7.5’
6.79
23.8’
22.1’
0° Spread: 115.5°
9.0’
4.71
28.5’
26.6’
90° Spread: 111.7°
0°
Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%
RCC %: RW %: 70 RCR: 0 .64 1 .58 2 .53 3 .48 4 .44 5 .41 6 .38 7 .35 8 .32 9 .30 10 .28
L103 4’ Length S3 Spacing 120°, Frosted 3000K Std 1360 lm
80
50 .64 .56 .49 .43 .38 .34 .30 .28 .25 .23 .21
30 .64 .54 .45 .38 .33 .29 .26 .23 .21 .19 .17
70
0 .64 .52 .42 .35 .30 .25 .22 .20 .17 .16 .14
70 .62 .57 .52 .47 .43 .40 .37 .34 .32 .29 .28
50 .62 .55 .48 .42 .37 .33 .30 .27 .25 .23 .21
50
30 .62 .53 .44 .38 .33 .29 .25 .23 .20 .18 .17
Polar Candela Distribution
0 .53 .45 .38 .32 .28 .24 .21 .19 .17 .15 .14
50 .60 .52 .46 .40 .36 .32 .29 .26 .24 .22 .20
30
30 .60 .51 .43 .37 .32 .28 .25 .22 .20 .18 .17
20 .60 .49 .41 .34 .29 .25 .22 .19 .17 .16 .14
50 .57 .50 .44 .39 .35 .31 .28 .25 .23 .21 .20
10
30 .57 .49 .42 .36 .31 .27 .24 .22 .20 .18 .16
20 .57 .48 .40 .33 .29 .25 .22 .19 .17 .15 .14
50 .55 .48 .42 .37 .33 .30 .27 .25 .23 .21 .19
0
30 .55 .47 .40 .35 .30 .27 .24 .21 .19 .18 .16
20 .55 .46 .39 .33 .28 .24 .21 .19 .17 .15 .14
0 .53 .45 .37 .32 .27 .23 .20 .18 .16 .14 .13
Illuminance at a Distance
180° -90°
Center Beam FC
90°
-45°
approx. 250 cd max.
45°
Beam Width
1.5’
108.97
4.7’
3.0’
27.24
9.3’
4.5’ 9.0’
4.5’
12.11
14.0’
13.5’
6.0’
6.81
18.7’
18.0’
7.5’
4.36
23.4’
22.5’
0° Spread: 114.6°
9.0’
3.03
28.0’
27.0’
90° Spread: 112.6°
0°
Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%
RCC %: RW %: 70 RCR: 0 .61 1 .56 2 .51 3 .47 4 .43 5 .39 6 .36 7 .33 8 .31 9 .29 10 .27
80
50 .61 .54 .47 .41 .36 .33 .29 .26 .24 .22 .20
30 .61 .52 .43 .37 .32 .28 .25 .22 .20 .18 .16
70
0 .61 .50 .40 .34 .28 .24 .21 .19 .17 .15 .14
70 .60 .55 .50 .45 .41 .38 .35 .33 .30 .28 .27
50 .60 .52 .46 .40 .36 .32 .29 .26 .24 .22 .20
50
30 .60 .51 .43 .36 .31 .28 .24 .22 .20 .18 .16
0 .51 .44 .37 .31 .27 .23 .20 .18 .16 .15 .13
50 .57 .50 .44 .39 .34 .31 .28 .25 .23 .21 .20
30
30 .57 .49 .41 .35 .31 .27 .24 .21 .19 .18 .16
20 .57 .47 .39 .33 .28 .24 .21 .19 .17 .15 .14
50 .55 .48 .42 .37 .33 .30 .27 .24 .22 .21 .19
10
30 .55 .47 .40 .34 .30 .26 .23 .21 .19 .17 .16
20 .55 .46 .38 .32 .27 .24 .21 .18 .16 .15 .13
50 .52 .46 .41 .36 .32 .29 .26 .24 .22 .20 .19
0
30 .52 .45 .39 .34 .29 .26 .23 .21 .19 .17 .16
20 .52 .44 .37 .31 .27 .23 .21 .18 .16 .15 .13
0 .51 .43 .36 .30 .26 .22 .20 .17 .15 .14 .12
Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
Copyright © MP Lighting. All technical information in this document is subject to change.
02-2011