Linear Strip Light
L104 wall mount bracket SPEC SHEET
Application: Wall mounted linear strip light Electrical: 4 x 1W or 6 x 1W LEDs/Ft. Powered by remote driver (not included). Input Current: S2 = 350mA/foot or S3 = 230mA/foot Input Voltage: 24V DC Power Consumption: S2 = 6W/foot or S3 = 4W/foot Recommended Driver: TLDAV100W24. Dimmable with 0~10V dimming controller (TLC010i, not included). Consult factory.
S (LED spacing)
Weight: 0.90lb (0.41kg)/foot. Material: Aluminum, polycarbonate, RoHS compliant.
1-1/4” 32mm
Mounting: Mounts directly to surface or by wall bracket (sold separately). Approval: Dry locations. Approved to US and Canadian standards by CSA.
1/8” 3mm
L (circuit board length)
50 2-3/4” 70mm
Type: Project: Modified: 3-1/8” 79mm
Quantity: Notes:
2-3/8” 60mm
Code L104
Length (L)
Spacing (S)
Color
Beam
Lens
-
2-3/4” S2 = 2” (51mm) 70mm S3 = 3” (76mm) between LEDs
4 = 4’ (1219mm) 8 = 8’ (2438mm) X = custom
Note: S2 = 12' (3658mm) max. per 100W24V driver S3 = 18' (5486mm) max. per 100W24V driver Code SDF070
Wall Mount Bracket
Power Feed
Finish
-
Finish -
W27S W30S W35S W41S W30H
= 2700K, std CRI = 3000K, std CRI = 3500K, std CRI = 4100K, std CRI = 3000K, high CRI
12 = 12° beam 30 = 30° beam
T = flat clear F = flat frosted
MA E = end feed T = top feed
MA = matte clear anodized
3-1/8” 79mm
MC
2-3/8” MC = matte chrome 60mm
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
Copyright © MP Lighting. All technical information in this document is subject to change.
02-2011
Linear Strip Light
L104 wall mount bracket SPEC SHEET Photometric Data
L104 4’ Length S2 Spacing 12°, Frosted 3000K Std 2040 lm
Polar Candela Distribution
Illuminance at a Distance
180° -90°
Center Beam FC
90°
-45°
approx. 3000 cd max.
45°
Beam Width
1.5’
1,351.38
0.6’
0.6’
3.0’
337.84
1.3’
1.3’
4.5’
150.15
1.9’
1.9’
6.0’
84.46
2.6’
2.6’
7.5’
54.06
3.2’
3.2’
0° Spread: 24.2°
9.0’
37.54
3.9’
3.9’
90° Spread: 24.2°
0°
Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%
RCC %: RW %: 70 RCR: 0 .73 1 .66 2 .60 3 .55 4 .50 5 .46 6 .43 7 .40 8 .37 9 .34 10 .32
L104 4’ Length S2 Spacing 30°, Frosted 3000K Std 2040 lm
80
50 .73 .64 .55 .49 .43 .38 .35 .31 .29 .26 .24
30 .73 .61 .51 .44 .38 .33 .29 .26 .23 .21 .19
70
0 .73 .59 .48 .40 .34 .29 .25 .22 .20 .18 .16
70 .71 .65 .59 .54 .49 .45 .42 .39 .36 .34 .31
50 .71 .62 .54 .48 .42 .38 .34 .31 .28 .26 .24
50
30 .71 .60 .50 .43 .37 .33 .29 .26 .23 .21 .19
Polar Candela Distribution
0 .61 .52 .43 .37 .32 .28 .24 .21 .19 .17 .16
50 .68 .59 .52 .46 .41 .36 .33 .30 .27 .25 .23
30
30 .68 .58 .49 .42 .36 .32 .28 .25 .23 .21 .19
20 .68 .56 .46 .39 .33 .28 .25 .22 .20 .18 .16
50 .65 .57 .50 .44 .39 .35 .32 .29 .26 .24 .23
10
30 .65 .55 .47 .41 .35 .31 .28 .25 .22 .20 .19
20 .65 .54 .45 .38 .32 .28 .25 .22 .19 .17 .16
50 .62 .55 .48 .42 .38 .34 .31 .28 .26 .24 .22
0
30 .62 .53 .46 .40 .35 .31 .27 .24 .22 .20 .18
20 .62 .52 .44 .37 .32 .28 .24 .22 .19 .17 .16
0 .61 .51 .43 .36 .31 .26 .23 .20 .18 .16 .15
Illuminance at a Distance
180° -90°
Center Beam FC
90°
-45°
approx. 1800 cd max.
45°
Beam Width
1.5’
786.24
1.0’
1.0’
3.0’
196.56
1.9’
1.9’
4.5’
87.36
2.9’
2.9’
6.0’
49.14
3.9’
3.9’
7.5’
31.45
4.8’
4.8’
0° Spread: 35.6°
9.0’
21.84
5.8’
5.8’
90° Spread: 35.8°
0°
Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%
RCC %: RW %: 70 RCR: 0 .71 1 .66 2 .62 3 .58 4 .54 5 .51 6 .48 7 .46 8 .43 9 .41 10 .39
80
50 .71 .64 .58 .53 .49 .45 .42 .39 .37 .35 .33
30 .71 .62 .55 .49 .45 .41 .38 .35 .33 .31 .29
70
0 .71 .60 .52 .46 .41 .38 .35 .32 .30 .28 .27
70 .69 .65 .60 .57 .53 .50 .47 .45 .43 .41 .39
50 .69 .63 .57 .52 .48 .44 .41 .39 .37 .34 .33
50
30 .69 .61 .54 .49 .44 .40 .37 .35 .33 .31 .29
0 .59 .53 .48 .43 .39 .36 .34 .31 .29 .28 .26
50 .66 .60 .55 .50 .47 .43 .40 .38 .36 .34 .32
30
30 .66 .59 .52 .47 .43 .40 .37 .34 .32 .30 .29
20 .66 .57 .50 .45 .41 .37 .34 .32 .30 .28 .26
50 .63 .58 .53 .49 .45 .42 .39 .37 .35 .33 .32
10
30 .63 .57 .51 .46 .42 .39 .36 .34 .32 .30 .28
20 .63 .56 .49 .44 .40 .37 .34 .32 .30 .28 .26
50 .61 .56 .51 .47 .44 .41 .39 .36 .34 .33 .31
0
30 .61 .55 .50 .45 .42 .38 .36 .34 .32 .30 .28
20 .61 .54 .48 .43 .40 .36 .34 .31 .29 .28 .26
0 .59 .53 .47 .42 .38 .35 .33 .30 .28 .27 .25
Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
Copyright © MP Lighting. All technical information in this document is subject to change.
02-2011
Linear Strip Light
L104 wall mount bracket SPEC SHEET Photometric Data
L104 4’ Length S3 Spacing 12°, Frosted 3000K Std 1360 lm
Polar Candela Distribution
Illuminance at a Distance
180° -90°
Center Beam FC
90°
-45°
approx. 2000 cd max.
45°
Beam Width
1.5’
901.27
0.6’
0.6’
3.0’
225.32
1.3’
1.3’
4.5’
100.14
1.9’
1.9’
6.0’
56.33
2.6’
2.6’
7.5’
36.05
3.2’
3.2’
0° Spread: 24.2°
9.0’
25.04
3.9’
3.9’
90° Spread: 24.2°
0°
Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%
RCC %: RW %: 70 RCR: 0 .71 1 .67 2 .62 3 .59 4 .55 5 .52 6 .50 7 .47 8 .45 9 .43 10 .41
L104 4’ Length S3 Spacing 30°, Frosted 3000K Std 1036 lm
80
50 .71 .64 .59 .54 .50 .46 .44 .41 .39 .37 .35
30 .71 .63 .56 .50 .46 .42 .39 .37 .35 .33 .32
70
0 .71 .61 .53 .47 .43 .39 .37 .34 .32 .31 .29
70 .69 .65 .61 .57 .54 .51 .49 .46 .44 .42 .41
50 .69 .63 .58 .53 .49 .46 .43 .41 .38 .37 .35
50
30 .69 .61 .55 .50 .45 .42 .39 .37 .35 .33 .31
Polar Candela Distribution
0 .60 .54 .48 .44 .41 .38 .35 .33 .32 .30 .29
50 .66 .61 .56 .51 .48 .45 .42 .40 .38 .36 .34
30
30 .66 .59 .53 .48 .45 .41 .39 .36 .34 .33 .31
20 .66 .58 .51 .46 .42 .39 .36 .34 .32 .30 .29
50 .63 .58 .54 .50 .46 .44 .41 .39 .37 .35 .34
10
30 .63 .57 .52 .47 .44 .41 .38 .36 .34 .32 .31
20 .63 .56 .50 .45 .42 .38 .36 .34 .32 .30 .29
50 .61 .56 .52 .48 .45 .43 .40 .38 .36 .35 .33
0
30 .61 .55 .50 .46 .43 .40 .38 .36 .34 .32 .31
20 .61 .54 .49 .45 .41 .38 .36 .33 .32 .30 .29
0 .60 .53 .48 .43 .40 .37 .35 .33 .31 .29 .28
Illuminance at a Distance
180° -90°
Center Beam FC
90°
-45°
approx. 1200 cd max.
45°
Beam Width
1.5’
523.97
1.0’
1.0’
3.0’
130.99
1.9’
1.9’
4.5’
58.22
2.9’
2.9’
6.0’
32.75
3.9’
3.9’
7.5’
20.96
4.8’
4.9’
0° Spread: 35.7°
9.0’
14.55
5.8’
5.8’
90° Spread: 35.9°
0°
Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%
RCC %: RW %: 70 RCR: 0 .71 1 .66 2 .62 3 .58 4 .54 5 .51 6 .48 7 .46 8 .43 9 .41 10 .39
80
50 .71 .64 .58 .53 .49 .45 .42 .39 .37 .35 .33
30 .71 .62 .55 .49 .45 .41 .38 .35 .33 .31 .29
70
0 .71 .60 .52 .46 .41 .38 .35 .32 .30 .28 .27
70 .69 .65 .60 .57 .53 .50 .47 .45 .43 .41 .39
50 .69 .63 .57 .52 .48 .44 .41 .39 .37 .34 .33
50
30 .69 .61 .54 .49 .44 .40 .37 .35 .33 .31 .29
0 .59 .53 .48 .43 .39 .36 .34 .31 .29 .28 .26
50 .66 .60 .55 .50 .47 .43 .40 .38 .36 .34 .32
30
30 .66 .59 .52 .47 .43 .40 .37 .34 .32 .30 .29
20 .66 .57 .50 .45 .41 .37 .34 .32 .30 .28 .26
50 .63 .58 .53 .49 .45 .42 .39 .37 .35 .33 .32
10
30 .63 .57 .51 .46 .42 .39 .36 .34 .32 .30 .28
20 .63 .56 .49 .44 .40 .37 .34 .32 .30 .28 .26
50 .61 .56 .51 .47 .44 .41 .39 .36 .34 .33 .31
0
30 .61 .55 .50 .45 .42 .38 .36 .34 .32 .30 .28
20 .61 .54 .48 .43 .40 .36 .34 .31 .29 .28 .26
0 .59 .53 .47 .42 .38 .35 .33 .30 .28 .27 .25
Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
Copyright © MP Lighting. All technical information in this document is subject to change.
02-2011