/L111_spec

Page 1

LED Downlight

L111

SPEC SHEET 10-7/8” 276mm 10-7/8” 276mm

5-7/8” 149mm 5-7/8” Application: 149mm

1-3/4” 44mm 1-3/4” 44mm

stem Input

L (length) 1-3/4” 44mm

10-7/8” 276mm 10-7/8” 276mm

stem 5-7/8” 149mm 5-7/8” 149mm

2-5/8” 67mm 2-5/8” 67mm

Current: Input Voltage: Power Consumption: 2-3/4” 70mm Dimming: 2-3/4” 70mm 1/4” 6mm 1/4”

5-7/8” 149mm

L (length) 5-7/8” 149mm

10-7/8” 276mm

S1 = 350mA/foot S2 = 230mA/foot 120V or 277V S1 = 12W/foot S2 = 6W/foot Dimmable with TLDAV100W24 with 0~10V dimming controller (TLC010i, not included). Consult factory.

6mm

Material: Anodized aluminum. Mounting: Mounts to ceiling using power canopy (included). 8’ (2438mm) 5-7/8” fixture comes with 2 stem supports, 6’ (1829mm) max drop.

1-3/4” 44mm 1-3/4” 44mm

149mm

5-7/8” Dry locations. Approved to US and Canadian standards by CSA. Approval: 149mm

50

drop drop

Type:

2-3/4” 70mm

L (length)

downlight.

Electrical: 1W LEDs (6W/Ft or 12W/Ft). Powered by surface mounted stem driver with optional dimming controller (included). Please specify.

2-5/8” 67mm 2-5/8” 67mm

10-7/8” 276mm

5-7/8” 149mm 5-7/8” Indoor149mm linear

S (LED spacing)

2-3/4” 70mm 2-3/4” 70mm

Project:

1/4” 6mm

1/4” 6mm 1/4” 6mm

L (length)

S (LED spacing)

L (length)

Quantity:

5-7/8” 149mm

1-3/4” 44mm

Modified:

Notes:

drop

1/4” 6mm

L (length)

Code

Mount

L111

Length (L)

Spacing (s)

Color

Beam

C = canopy (non-dimmable) CD = canopy (dimmable)

Drop -

4 = 4’ (1219mm) 6 = 6’ (1829mm) 8 = 8’ (2438mm)*

S1 = 1” (25mm) S2 = 2” (51mm) between LEDs

*8' length fixture only available in S2 spacing.

t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada

W27S = 2700K, std CRI 12 = 12° W30S = 3000K, std CRI 30 = 30° W35S = 3500K, std CRI W41S = 4100K, std CRI W30H = 3000K, high CRI

Finish MA

6 = 6” (152mm) min. X = custom length, 6’ (1829mm) max.

Copyright © MP Lighting. All technical information in this document is subject to change.

MA = matte clear anodized

02-2011


LED Downlight

L111

SPEC SHEET Photometric Data

L111 4’ Length S1 Spacing 12° 3000K Std 4080 lm

Polar Candela Distribution

Illuminance at a Distance

180° -90°

Center Beam FC

90°

-45°

approx. 17500 cd max.

45°

Beam Width

1.5’

7,758.38

0.6’

0.6’

3.0’

1,939.60

1.2’

1.2’

4.5’

862.04

1.8’

1.8’

6.0’

484.90

2.5’

2.5’

7.5’

310.34

3.1’

3.1’

0° Spread: 23.1°

9.0’

215.51

3.7’

3.7’

90° Spread: 23.2°

Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%

RCC %: RW %: RCR: 0 1 2 3 4 5 6 7 8 9 10

L111 4’ Length S1 Spacing 30° 3000K Std 4080 lm

80

70

70 50 30 0 1.20 1.20 1.20 1.20 1.15 1.13 1.10 1.08 1.10 1.06 1.02 .99 1.06 1.00 .96 .92 1.02 .95 .91 .87 .98 .91 .86 .83 .95 .87 .82 .79 .92 .84 .79 .76 .89 .81 .76 .73 .86 .78 .74 .70 .84 .76 .71 .68

50

30

10

0

0 70 50 30 0 50 30 20 50 30 20 50 30 20 1.18 1.18 1.18 1.01 1.12 1.12 1.12 1.08 1.08 1.08 1.03 1.03 1.03 1.01 1.13 1.10 1.08 .96 1.06 1.05 1.03 1.03 1.01 1.00 .99 .98 .97 .95 1.08 1.04 1.01 .91 1.01 .98 .96 .98 .96 .94 .95 .94 .92 .90 1.04 .99 .95 .87 .96 .93 .90 .94 .91 .89 .92 .89 .88 .86 1.00 .94 .90 .83 .92 .89 .86 .90 .87 .85 .89 .86 .84 .82 .97 .90 .86 .80 .89 .85 .82 .87 .84 .81 .86 .83 .80 .79 .94 .87 .82 .77 .85 .81 .78 .84 .80 .78 .83 .80 .77 .76 .91 .83 .79 .74 .82 .78 .75 .81 .77 .75 .80 .77 .74 .73 .88 .81 .76 .72 .80 .75 .72 .79 .75 .72 .78 .74 .72 .71 .85 .78 .73 .69 .77 .73 .70 .76 .72 .70 .75 .72 .70 .68 .83 .75 .71 .67 .75 .71 .68 .74 .70 .68 .73 .70 .67 .66

Polar Candela Distribution

Illuminance at a Distance

180° -90°

Center Beam FC

90°

-45°

approx. 9500 cd max.

45°

Beam Width

1.5’

4,299.63

0.9’

0.9’

3.0’

1,074.91

1.8’

1.8’

4.5’

477.74

2.7’

2.7’

6.0’

268.73

3.6’

3.6’

7.5’

171.99

4.5’

4.5’

0° Spread: 33.5°

9.0’

119.43

5.4’

5.4’

90° Spread: 33.3°

Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%

RCC %: RW %: RCR: 0 1 2 3 4 5 6 7 8 9 10

80

70 50 30 0 1.21 1.21 1.21 1.21 1.15 1.12 1.09 1.07 1.09 1.04 1.00 .97 1.04 .98 .93 .89 .99 .92 .87 .83 .95 .87 .82 .77 .91 .83 .77 .73 .87 .79 .73 .69 .84 .75 .70 .66 .81 .72 .67 .63 .78 .69 .64 .60

70

50

30

10

0

0 70 50 30 0 50 30 20 50 30 20 50 30 20 1.18 1.18 1.18 1.01 1.13 1.13 1.13 1.08 1.08 1.08 1.03 1.03 1.03 1.01 1.12 1.10 1.07 .95 1.06 1.04 1.02 1.02 1.00 .99 .98 .97 .96 .94 1.07 1.03 .99 .89 .99 .96 .93 .96 .94 .91 .93 .91 .90 .88 1.02 .96 .92 .83 .94 .90 .87 .91 .88 .85 .89 .86 .84 .82 .98 .91 .86 .79 .89 .84 .81 .87 .83 .80 .85 .82 .79 .78 .94 .86 .81 .75 .84 .80 .76 .83 .79 .76 .81 .78 .75 .74 .90 .82 .77 .71 .80 .76 .72 .79 .75 .72 .78 .74 .71 .70 .86 .78 .73 .68 .77 .72 .69 .76 .71 .68 .75 .71 .68 .67 .83 .75 .69 .65 .74 .69 .65 .73 .68 .65 .72 .68 .65 .64 .80 .71 .66 .62 .71 .66 .63 .70 .65 .62 .69 .65 .62 .61 .77 .69 .63 .59 .68 .63 .60 .67 .63 .60 .66 .62 .60 .58

Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.

t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada

Copyright © MP Lighting. All technical information in this document is subject to change.

02-2011


LED Downlight

L111

SPEC SHEET Photometric Data

L111 4’ Length S2 Spacing 12° 3000K Std 2040 lm

Polar Candela Distribution

Illuminance at a Distance

180° -90°

Center Beam FC

90°

-45°

approx. 9000 cd max.

45°

Beam Width

1.5’

3,877.67

0.6’

0.6’

3.0’

969.42

1.2’

1.2’

4.5’

430.85

1.8’

1.8’

6.0’

242.35

2.5’

2.5’

7.5’

155.11

3.1’

3.1’

0° Spread: 23.1°

9.0’

107.71

3.7’

3.7’

90° Spread: 23.2°

Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%

RCC %:

80

70

RW %: 70 50 30 0 RCR: 0 1.20 1.20 1.20 1.20 1 1.15 1.13 1.10 1.08 2 1.10 1.06 1.02 .99 3 1.06 1.00 .96 .92 4 1.02 .95 .91 .87 5 .98 .91 .86 .83 6 .95 .87 .82 .79 7 .92 .84 .79 .76 8 .89 .81 .76 .73 9 .86 .78 .73 .70 10 .84 .76 .71 .68

L111 4’ Length S2 Spacing 30° 3000K Std 2040 lm

50

30

10

0

0 70 50 30 0 50 30 20 50 30 20 50 30 20 1.18 1.18 1.18 1.01 1.12 1.12 1.12 1.08 1.08 1.08 1.03 1.03 1.03 1.01 1.13 1.10 1.08 .96 1.06 1.05 1.03 1.03 1.01 1.00 .99 .98 .97 .95 1.08 1.04 1.01 .91 1.01 .98 .96 .98 .96 .94 .95 .94 .92 .90 1.04 .99 .95 .87 .96 .93 .90 .94 .91 .89 .92 .89 .87 .86 1.00 .94 .90 .83 .92 .89 .86 .90 .87 .85 .89 .86 .84 .82 .97 .90 .86 .80 .89 .85 .82 .87 .84 .81 .85 .83 .80 .79 .94 .87 .82 .77 .85 .81 .78 .84 .80 .78 .83 .80 .77 .76 .91 .83 .79 .74 .82 .78 .75 .81 .77 .75 .80 .77 .74 .73 .88 .81 .76 .72 .79 .75 .72 .79 .75 .72 .78 .74 .72 .71 .85 .78 .73 .69 .77 .73 .70 .76 .72 .70 .75 .72 .69 .68 .83 .75 .71 .67 .75 .71 .68 .74 .70 .68 .73 .70 .67 .66

Polar Candela Distribution

Illuminance at a Distance

180° -90°

Center Beam FC

90°

-45°

approx. 5000 cd max.

45°

Beam Width

1.5’

2,145.86

0.9’

0.9’

3.0’

536.46

1.8’

1.8’

4.5’

238.43

2.7’

2.7’

6.0’

134.12

3.6’

3.6’

7.5’

85.83

4.5’

4.5’

0° Spread: 33.5°

9.0’

59.61

5.4’

5.4’

90° Spread: 33.4°

Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%

RCC %:

80

RW %: 70 50 30 0 RCR: 0 1.21 1.21 1.21 1.21 1 1.15 1.12 1.09 1.07 2 1.09 1.04 1.00 .97 3 1.04 .98 .93 .89 4 .99 .92 .87 .83 5 .95 .87 .81 .77 6 .91 .83 .77 .73 7 .87 .79 .73 .69 8 .84 .75 .70 .66 9 .81 .72 .66 .63 10 .78 .69 .64 .60

70

50

30

10

0

0 70 50 30 0 50 30 20 50 30 20 50 30 20 1.18 1.18 1.18 1.01 1.13 1.13 1.13 1.08 1.08 1.08 1.03 1.03 1.03 1.01 1.12 1.10 1.07 .95 1.05 1.04 1.02 1.02 1.00 .99 .98 .97 .96 .94 1.07 1.02 .99 .89 .99 .96 .93 .96 .94 .91 .93 .91 .90 .88 1.02 .96 .92 .83 .94 .90 .87 .91 .88 .85 .89 .86 .84 .82 .98 .91 .86 .79 .89 .84 .81 .87 .83 .80 .85 .82 .79 .78 .93 .86 .81 .75 .84 .80 .76 .83 .79 .76 .81 .78 .75 .74 .90 .82 .77 .71 .80 .76 .72 .79 .75 .72 .78 .74 .71 .70 .86 .78 .73 .68 .77 .72 .69 .76 .71 .68 .75 .71 .68 .67 .83 .75 .69 .65 .74 .69 .65 .73 .68 .65 .72 .68 .65 .64 .80 .71 .66 .62 .71 .66 .62 .70 .65 .62 .69 .65 .62 .61 .77 .69 .63 .59 .68 .63 .60 .67 .63 .60 .66 .62 .60 .58

Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.

t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada

Copyright © MP Lighting. All technical information in this document is subject to change.

02-2011


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.