1W/2.5W Walkway
L13
SPEC SHEET Application: Indoor stair, ramp, aisle, and walkway illumination. Electrical: 1W LED powered by 120V primary, 3W 350mA non-dimmable integral driver or 2.5W LED powered by 120V primary, 700mA nondimmable integral driver. Input Current: 350mA (1W) / 700mA (2.5W) Input Voltage: 4V DC Power Consumption: 1W / 2.5W Recommended Dimmable Driver: LED8W350i (1W) and LED20W700i (2.5W). Dimmable driver not included. Consult factory. Weight: 0.78lbs (0.353kg). Material: Plated brass, anodized aluminum. RoHS compliant. Mounting: Vertically or horizontally positioned face plate mounts to single gang box with flush mounted tamper proof screws. Optimal mounting distance is 18” - 24” (457mm - 610mm) AFF. 1-1/4” 32mm
3-1/8” 79mm
Approval: Dry locations. Approved to US and Canadian standards by CSA. 50 1-1/2” 38mm Note: Can be used as emergency backup lighting in conjunction with Bodine emergency LED
4-3/4” 121mm
1-3/4” 44mm
3-1/4” 83mm
driver (sold separately). Consult MP Lighting factory. 1-3/8” 35mm
Ø1-1/2” Ø38mm
Type:
Shown as 12° or 30° beam Vertical plate
” m
Project:
3-1/8” 79mm
Modified: 1-3/4” 44mm 1-1/2” 38mm 1-3/8” 35mm
1-1/2” 38mm
4-3/4” 121mm
Notes:
Ø1-1/2” Ø38mm Shown as 120° beam
Shown as 120° beam Vertical plate
Horizontal plate
Code L13
Quantity:
Wattage
Color
Beam
Plate
-
Finish -
1 = 1W 2 = 2.5W*
W27S W30S W35S W41S W30H
= 2700K, std CRI = 3000K, std CRI = 3500K, std CRI = 4100K, std CRI = 3000K, high CRI
S = spot (12°) N = narrow flood (30°) W= wide flood (120°)
V = vertical H = horizontal
MC = matte chrome BK = powder coated black BN = brushed nickel
*Only available in W30S (3000k, std CRI)
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
Copyright © MP Lighting. All technical information in this document is subject to change.
05-2011
1W/2.5W Walkway
L13
SPEC SHEET Photometric Data
L13 1W, 12° 3000K Std 85 lm
Polar Candela Distribution 180°
2
-90°
90°
1
0
2
approx. 750 cd max.
45°
3
-0°
4
-90°
5
Polar Candela Distribution
2 90°
1
0
2
approx. 300 cd max.
45°
3
-0°
4
-90°
5
Polar Candela Distribution 180°
2
-90°
90°
1
New Mounting Height² Step 2
= Correction Factor (CF)
CF x Footcandle = New Mounting Height FC
Note: Information is based on the most current data available; however, various operating factors such as reflectances and application type may cause differences between lab and field results. Due to continuous improvements, specifications may change without notice. Consult www.mplighting.com for the most current information.
0
1
2
3
approx. 35 cd max.
45°
0
1
2
3
0
20 2.5 0.5
2 3
-0°
4
-90°
5
0.1 fc
Mount height: 1 ft Total LLF: 1
0°
Polar Candela Distribution
Isofootcandle Plot
180°
2
-90°
90°
0 1
-45°
Existing Mounting Height²
Isofootcandle Plot
1
L13 2.5W, 12° 3000K Std 162 lm
Step 1
Mount height: 1 ft Total LLF: 1
0°
-45°
3
20 1.0 0.2 0.1 fc
1
L13 1W, 120° 3000K Std 85 lm
2
Isofootcandle Plot
180° -90°
-45°
1
Mount height: 1 ft Total LLF: 1
0°
L13 1W, 30° 3000K Std 85 lm
0
20 1.0 0.2 0.1 fc
1
-45°
Height Conversion Formula
Isofootcandle Plot
approx. 1500 cd max.
45°
0°
1
0
0.5
3
0.1 fc
4
-90°
5
2
3
20 5
2
-0°
1
Mount height: 1 ft Total LLF: 1
Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
Copyright © MP Lighting. All technical information in this document is subject to change.
05-2011
1W/2.5W Walkway
L13
SPEC SHEET Photometric Data
L13 2.5W, 30° 3000K Std 162 lm
Polar Candela Distribution 180°
2
-90°
90°
1
0
approx. 550 cd max.
45°
2
0.5
3
0.1 fc
-0°
4
-90°
5
Polar Candela Distribution
2
3
Step 1
2 90°
New Mounting Height² Step 2
= Correction Factor (CF)
CF x Footcandle = New Mounting Height FC
Note: Information is based on the most current data available; however, various operating factors such as reflectances and application type may cause differences between lab and field results. Due to continuous improvements, specifications may change without notice. Consult www.mplighting.com for the most current information.
45°
0°
1
0
1
2
3
0 1
approx. 70 cd max.
Existing Mounting Height²
Isofootcandle Plot
180° -90°
-45°
1
Mount height: 1 ft Total LLF: 1
0°
L13 2.5W, 120° 3000K Std 162 lm
0
20 2.5
1
-45°
Height Conversion Formula
Isofootcandle Plot
20
2
2.5
3
0.5
-0°
4
-90°
5
0.1 fc Mount height: 1 ft Total LLF: 1
Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
Copyright © MP Lighting. All technical information in this document is subject to change.
05-2011