13W Recessed Downlight
L141-NI
SPEC SHEET Application: Indoor downlight with field replaceable LED lamp. Electrical: 13W LED powered by 700mA integral dimmable or nondimmable driver (please specify). Shown with round trim (R) and white finish (W).
Input Current: 0.12A Input Voltage: 120V AC Power Consumption: 15W Dimming: 0-10V (120V input only). A control lead is required to connect each dimmable driver to the controlling dimmer switch. Weight: 6.21lbs (2.82kg)
Shown with square trim (S) and black finish (B)
Material: Aluminum. Mounting: Recessed mount non-insulated version to ceiling with friction fit spring clips. Ceiling Cutout Size: 4” (102mm) Approval: Dry and damp locations. Approved to US and Canadian standards by CSA.
5-3/8” 137mm
44 Note: Can be used as emergency backup lighting in conjunction with Bodine emergency LED driver. Consult MP Lighting factory.
Type: Project: Ø4-7/8” 7-5/8” Ø124mm 194mm
Modified: Quantity: 9-1/2” 241mm
Notes:
Up to 24” / 610mm
Code L141
housing -
Dimming
NI NI = non-insulated
Wattage
Color
Reflector
Trim
13 ND = non-dimmable D = dimmable
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
13 = 13W
Finish -
W30S = 3000K, std CRI W50S = 5000K, std CRI
30 = 30° 45 = 45°
R = round S = square
Copyright © MP Lighting. All technical information in this document is subject to change.
W = white B = black
02-2011
13W Recessed Downlight
L141-NI
SPEC SHEET Photometric Data
L141 30° 3000K Std 960 lm
Polar Candela Distribution
Illuminance at a Distance
180° -90°
Center Beam FC
90°
-45°
approx. 2700 cd max.
45°
Beam Width
1.5’
1,198.93
0.8’
0.8’
3.0’
299.73
1.5’
1.5’
4.5’
133.21
2.3’
2.3’
6.0’
74.93
3.1’
3.1’
7.5’
47.96
3.8’
3.8’
0° Spread: 28.8°
9.0’
33.30
4.6’
4.6’
90° Spread: 28.8°
0°
Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%
L141 45° 3000K Std 960 lm
RCC %:
80
70
RW %: RCR: 0 1 2 3 4 5 6 7 8 9 10
70 50 30 0 1.19 1.19 1.19 1.19 1.15 1.12 1.10 1.08 1.10 1.06 1.02 .99 1.06 1.00 .96 .92 1.01 .95 .90 .87 .97 .90 .85 .82 .93 .86 .81 .77 .90 .82 .77 .73 .86 .78 .73 .70 .83 .75 .70 .67 .80 .72 .67 .64
50
30
10
0
70 50 30 0 50 30 20 50 30 20 50 30 20 1.17 1.17 1.17 1.00 1.11 1.11 1.11 1.07 1.07 1.07 1.02 1.02 1.02 1.12 1.10 1.08 .96 1.06 1.05 1.03 1.02 1.01 1.00 .99 .98 .97 1.08 1.04 1.01 .91 1.01 .98 .96 .98 .96 .94 .95 .94 .92 1.04 .99 .95 .87 .96 .93 .90 .94 .91 .89 .92 .89 .87 1.00 .94 .89 .83 .92 .88 .85 .90 .87 .84 .88 .85 .83 .96 .89 .85 .79 .88 .84 .80 .86 .82 .80 .84 .82 .79 .92 .85 .80 .75 .84 .80 .76 .82 .79 .76 .81 .78 .75 .89 .81 .77 .72 .80 .76 .73 .79 .75 .72 .78 .75 .72 .85 .78 .73 .69 .77 .73 .69 .76 .72 .69 .75 .72 .69 .82 .75 .70 .66 .74 .69 .66 .73 .69 .66 .72 .69 .66 .79 .72 .67 .63 .71 .67 .64 .70 .66 .64 .70 .66 .63
Polar Candela Distribution
0 1.00 .95 .91 .86 .82 .78 .74 .71 .68 .65 .62
Illuminance at a Distance
180° -90°
Center Beam FC
90°
-45°
approx. 1600 cd max.
45°
Beam Width
1.5’
714.51
1.2’
1.2’
3.0’
178.63
2.4’
2.4’
4.5’
79.39
3.5’
3.5’
6.0’
44.66
4.7’
4.7’
7.5’
28.58
5.9’
5.9’
0° Spread: 43.0°
9.0’
19.85
7.1’
7.1’
90° Spread: 42.9°
0°
Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%
RCC %:
80
RW %: RCR: 0 1 2 3 4 5 6 7 8 9 10
70 50 30 0 1.19 1.19 1.19 1.19 1.14 1.11 1.09 1.07 1.09 1.04 1.01 .98 1.04 .98 .94 .90 .99 .92 .87 .84 .95 .87 .82 .78 .91 .83 .77 .73 .87 .78 .73 .69 .83 .74 .69 .65 .79 .71 .65 .62 .76 .67 .62 .58
70
50
30
10
70 50 30 0 50 30 20 50 30 20 50 30 20 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.12 1.09 1.07 .95 1.05 1.04 1.02 1.02 1.00 .99 .98 .97 .96 1.07 1.03 .99 .90 1.00 .97 .94 .97 .94 .92 .94 .92 .90 1.02 .97 .93 .85 .94 .91 .88 .92 .89 .86 .90 .87 .85 .98 .91 .87 .80 .89 .85 .82 .87 .84 .81 .85 .83 .80 .93 .86 .81 .75 .85 .80 .77 .83 .79 .76 .81 .78 .76 .89 .82 .77 .71 .80 .76 .72 .79 .75 .72 .78 .74 .71 .85 .78 .72 .67 .76 .72 .68 .75 .71 .68 .74 .70 .68 .82 .74 .68 .64 .73 .68 .65 .72 .67 .64 .71 .67 .64 .78 .70 .65 .61 .69 .65 .61 .68 .64 .61 .68 .64 .61 .75 .67 .62 .58 .66 .61 .58 .65 .61 .58 .65 .61 .58
0 0 1.00 .94 .89 .84 .79 .74 .70 .66 .63 .60 .57
Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
Copyright © MP Lighting. All technical information in this document is subject to change.
02-2011