/L15_spec

Page 1

2 x 1W/2.5W Up and Down Walkway

L15

SPEC SHEET Application: Indoor stair, ramp, aisle, and walkway illumination. Electrical: 2 x 1W LEDs powered by 120V primary, 3W 350mA nondimmable integral driver or 2 x 2.5W LEDs powered by 120V primary, 700mA non-dimmable integral driver. Input Current: 350mA (1W) / 700mA (2.5W) Input Voltage: 8V DC Power Consumption: 2W / 5W Recommended Dimmable Driver: LED8W350i (2W) and LED20W700i (5W). Dimmable driver not included. Consult factory. Weight: 1.03lbs (0.467kg). Material: Plated brass, anodized aluminum. RoHS compliant. Mounting: Vertically positioned face plate mounts to a single gang box with flush mounted tamper proof screws. Approval: Wet and dry locations. Approved to US and Canadian standards by CSA. 3-1/8” 79mm

1-1/2” 38mm

50 Note: Can be used as emergency backup lighting in conjunction with Bodine emergency LED 1-5/8” driver (sold separately). Consult MP Lighting factory.

4-3/4” 121mm

3-1/4” 83mm 7/8” 2-1/8” 22mm 54mm

1-3/8” 35mm

41mm

Type:

1-1/2” 38mm

Project:

Shown as 12° or 30° beam

3-1/8” 3-1/8” 79mm 79mm

Modified: 4-3/4” 4-3/4” 121mm 121mm

Quantity:

1-5/8” 1-5/8” 41mm 41mm

1-1/2” 1-1/2” 38mm 38mm

Notes: Shown as 120° beam

Code L15

Wattage

Color UP

Beam UP

Color Down

Beam Down

-

Finish -

1 = 1W 2 = 2.5W*

W27S W30S W35S W41S W30H

= 2700K, std CRI = 3000K, std CRI = 3500K, std CRI = 4100K, std CRI = 3000K, high CRI

W27S = 2700K, std CRI S = spot (12°) N = narrow flood (30°) W30S = 3000K, std CRI W= wide flood (120°) W35S = 3500K, std CRI W41S = 4100K, std CRI W30H = 3000K, high CRI

S = spot (12°) N = narrow flood (30°) W= wide flood (120°)

MC = matte chrome BK = powder coated black BN = brushed nickel

*Only available in W30S (3000k, std CRI)

t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada

Copyright © MP Lighting. All technical information in this document is subject to change.

05-2011


2 x 1W/2.5W Up and Down Walkway

L15

SPEC SHEET Photometric Data

L15 2 x 1W, 12° 3000K Std 170 lm

Polar Candela Distribution 180°

2

-90°

90°

1

0

2

approx. 750 cd max.

45°

3

-0°

4

-90°

5

Polar Candela Distribution

2 90°

1

0

2

approx. 300 cd max.

45°

3

-0°

4

-90°

5

Polar Candela Distribution 180°

2

-90°

90°

1

New Mounting Height² Step 2

= Correction Factor (CF)

CF x Footcandle = New Mounting Height FC

Note: Information is based on the most current data available; however, various operating factors such as reflectances and application type may cause differences between lab and field results. Due to continuous improvements, specifications may change without notice. Consult www.mplighting.com for the most current information.

0

1

2

3

approx. 35 cd max.

45°

0

1

2

3

0

20 2.5 0.5

2 3

-0°

4

-90°

5

0.1 fc

Mount height: 1 ft Total LLF: 1

Polar Candela Distribution

Isofootcandle Plot

180°

2

-90°

90°

0 1 2

-45°

Existing Mounting Height²

Isofootcandle Plot

1

L15 2 x 2.5W, 12° 3000K Std 324 lm

Step 1

Mount height: 1 ft Total LLF: 1

-45°

3

20 1.0 0.2 0.1 fc

1

L15 2 x 1W, 120° 3000K Std 170 lm

2

Isofootcandle Plot

180° -90°

-45°

1

Mount height: 1 ft Total LLF: 1

L15 2 x 1W, 30° 3000K Std 170 lm

0

20 1.0 0.2 0.1 fc

1

-45°

Height Conversion Formula

Isofootcandle Plot

approx. 1500 cd max.

45°

3

-0°

4

-90°

5

1

0

1

2

3

20 2.5 0.5 0.1 fc

Mount height: 1 ft Total LLF: 1

Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.

t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada

Copyright © MP Lighting. All technical information in this document is subject to change.

05-2011


2 x 1W/2.5W Up and Down Walkway

L15

SPEC SHEET Photometric Data

L15 2 x 2.5W, 30° 3000K Std 324 lm

Polar Candela Distribution 180°

2

-90°

90°

1

0

approx. 550 cd max.

45°

2 3

0.1 fc

-0°

4

-90°

5

Polar Candela Distribution

2

3

Step 1

2 90°

approx. 70 cd max.

Existing Mounting Height² New Mounting Height²

Step 2

= Correction Factor (CF)

CF x Footcandle = New Mounting Height FC

Note: Information is based on the most current data available; however, various operating factors such as reflectances and application type may cause differences between lab and field results. Due to continuous improvements, specifications may change without notice. Consult www.mplighting.com for the most current information.

Isofootcandle Plot

180° -90°

-45°

1

Mount height: 1 ft Total LLF: 1

L15 2 x 2.5W, 120° 3000K Std 324 lm

0

20 2.5 0.5

1

-45°

Height Conversion Formula

Isofootcandle Plot

45°

1

0

1

2

3

0 1

20

2

2.5

3

0.5

-0°

4

-90°

5

0.1 fc Mount height: 1 ft Total LLF: 1

Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.

t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada

Copyright © MP Lighting. All technical information in this document is subject to change.

05-2011


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.