180° max.
Linear Rail Light- Standard Wall Mount
L171W
SPEC SHEET Application: Outdoor/indoor wall grazing illumination. Electrical: 1W, 350mA LEDs (4W/Ft or 6W/Ft). Powered by remote 120V primary, constant voltage driver (not included). Input Current: S2 = 350mA/foot S3 = 230mA/foot LED Input Voltage: 24V DC Power Consumption: S2 = 8W/foot S3 = 7W/foot Recommended Driver: TLDAV100W24. Dimmable with TLC010i dimming controller (not included). Consult factory. Weight: 0.26lbs (0.12kg)/foot Material: Heavy duty powder coated aluminum housing with tempered glass. Replaceable internal potted circuit boards and LEDs mounted to extruded aluminum heat sink. RoHS compliant. 2-1/4” 57mm
Mounting: Wall, ceiling or surface mounted via adjustable and lockable mounting bracket (2 mounting brackets included).
L (length)
Approval: Wet and dry locations. Approved to US and Canadian standards by CSA.
5” 127mm S (LED spacing)
65
1-3/4” 45mm
Note: Standard 6’ (1829mm) 18 AWG water proof electrical lead is rear mounted to enable continuous row mounting. 2-1/4” 57mm
1-3/8” 35mm
1-3/4” 44mm
1-5/8” 41mm
1” 25mm
Ø3/8” Ø10mm
180° max.
L (length)
7/8” 22mm
Type: Project:
2-3/4” 70mm
5” 127mm
S (LED spacing)
Modified:
1-3/4” 45mm
Quantity: Notes: 1-3/8” 35mm
Code
Mount
L171
W W = standard wall bracket
length (l)
1-3/4” 44mm
1-5/8” 41mm
1” 25mm
Ø3/8” Ø10mm
spacing (s)
7/8” 22mm
color
2-3/4” 70mm
Beam
Lead Length
-
Finish -
2 = 2’ S2 = 2” (51mm) btween LEDs (23-13/16”/605mm) S3 = 3” (76mm) between LEDs 4 = 4’ (47-5/8”/1210mm)
W27S W30S W35S W41S W20H W30H
= 2700K, std CRI = 3000K, std CRI = 3500K, std CRI = 4100K, std CRI = 2000K, high CRI = 3000K, high CRI
S = spot (12°) N = narrow flood (30°)
6 = 6’ (1829mm) standard X = custom
MP MP = matte pewter
Note: Standard CRI has a value of 75~82 while high CRI has 92.
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
W20H has consistent binning that falls within 1.5 MacAdam ellipse.
Copyright © MP Lighting. All technical information in this document is subject to change.
11-2011
Linear Rail Light- Standard Wall Mount
L171W
SPEC SHEET
Lumen test results provided by MP Lighting integrating sphere
Photometric Data
L171 4’ Length S2 Spacing 12° 3000K Std 1113 lm
Polar Candela Distribution
Chromaticity Diagram
Illuminance at a Distance
180° -90°
Center Beam FC
90°
-45°
approx. 7500 cd max.
45°
Beam Width
3.0’
861.68
1.2’
1.2’
6.0’
215.42
2.5’
2.5’
9.0’
95.74
3.7’
3.7’
12.0’
53.86
4.9’
4.9’
15.0’
34.47
6.1’
6.1’
18.0’
23.94
7.4’
7.4’
0° Spread: 23.1°
0°
90° Spread: 23.1°
Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%
RCC %:
80
70
RW %: 70 50 30 0 70 50 30 RCR: 0 1.04 1.04 1.04 1.04 1.02 1.02 1.02 1 1.00 .98 .96 .95 .98 .96 .95 2 .96 .93 .90 .87 .95 .91 .89 3 .93 .88 .84 .82 .91 .87 .84 4 .89 .84 .80 .77 .88 .83 .79 5 .86 .80 .76 .73 .85 .79 .76 6 .83 .77 .73 .70 .82 .76 .72 7 .81 .74 .70 .67 .80 .74 .70 8 .78 .71 .67 .65 .77 .71 .67 9 .76 .69 .65 .62 .75 .69 .65 10 .73 .67 .63 .60 .73 .67 .63
L171 4’ Length S2 Spacing 30° 3000K Std 1180 lm
Polar Candela Distribution
50 0 .88 .84 .80 .77 .74 .71 .68 .66 .64 .62 .60
30
50 30 .97 .97 .93 .92 .89 .86 .85 .82 .81 .78 .78 .75 .75 .72 .73 .69 .70 .67 .68 .64 .66 .62
20 .97 .90 .84 .80 .76 .72 .69 .67 .64 .62 .60
50 30 .93 .93 .90 .89 .86 .84 .83 .80 .80 .77 .77 .74 .74 .71 .72 .69 .69 .66 .67 .64 .65 .62
10 20 .93 .88 .83 .78 .75 .72 .69 .66 .64 .62 .60
50 .90 .87 .84 .81 .78 .75 .73 .71 .69 .67 .65
30 .90 .86 .82 .79 .76 .73 .70 .68 .66 .64 .62
0 20 .90 .85 .81 .77 .74 .71 .68 .66 .64 .62 .60
0 .88 .84 .80 .76 .73 .70 .67 .65 .63 .61 .59
ANSI Bin
MacAdam Ellipse
Illuminance at a Distance
180° -90°
Center Beam FC
90°
-45°
approx. 4300 cd max.
45°
Beam Width
3.0’
477.25
1.8’
1.8’
6.0’
119.31
3.6’
3.6’
9.0’
53.03
5.4’
5.4’
12.0’
29.09
7.2’
7.2’
15.0’
19.09
9.0’
9.0’
18.0’
13.26
10.8’
10.8’
0°
0° Spread: 33.5°
90° Spread: 33.4°
Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%
RCC %:
80
RW %: 70 50 RCR: 0 1.04 1.04 1 .99 .97 2 .95 .91 3 .91 .85 4 .87 .81 5 .83 .76 6 .80 .73 7 .76 .69 8 .73 .66 9 .71 .63 10 .68 .61
70
30 0 70 50 30 0 1.04 1.04 1.01 1.01 1.01 .87 .95 .93 .97 .95 .93 .82 .87 .85 .93 .89 .86 .78 .81 .78 .89 .84 .80 .73 .76 .73 .85 .80 .76 .69 .72 .68 .82 .76 .71 .66 .68 .65 .78 .72 .68 .63 .64 .61 .75 .69 .64 .60 .61 .58 .72 .66 .61 .57 .59 .56 .70 .63 .59 .55 .56 .53 .67 .60 .56 .53
50 50 30 .97 .97 .92 .90 .87 .84 .82 .79 .78 .74 .74 .70 .71 .67 .68 .64 .65 .61 .62 .58 .60 .56
30 20 .97 .89 .82 .76 .72 .67 .64 .61 .58 .55 .53
50 30 .93 .93 .88 .87 .84 .82 .80 .77 .76 .73 .73 .69 .69 .66 .67 .63 .64 .60 .61 .58 .59 .55
10 20 .93 .86 .80 .75 .71 .67 .63 .60 .58 .55 .53
50 .89 .85 .82 .78 .74 .71 .68 .66 .63 .61 .58
30 .89 .84 .80 .76 .72 .69 .65 .63 .60 .57 .55
0 20 .89 .84 .78 .74 .70 .66 .63 .60 .57 .55 .53
0 .87 .82 .77 .73 .69 .65 .62 .59 .56 .54 .52
Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
Copyright © MP Lighting. All technical information in this document is subject to change.
10-2011
Linear Rail Light- Standard Wall Mount
L171W
SPEC SHEET
Lumen test results provided by MP Lighting integrating sphere
Photometric Data
L171 4’ Length S3 Spacing 12° 3000K Std 738 lm
Polar Candela Distribution
Illuminance at a Distance
180°
Center Beam FC
-90°
90°
-45°
approx. 5000 cd max.
45°
Beam Width
3.0’
561.93
1.2’
1.2’
6.0’
140.48
2.5’
2.5’
9.0’
62.44
3.7’
3.7’
12.0’
35.12
4.9’
4.9’
15.0’
22.48
6.1’
6.1’
18.0’
15.61
7.4’
7.4’
0° Spread: 23.2°
0°
90° Spread: 23.1°
Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%
RCC %:
80
RW %: 70 50 RCR: 0 1.02 1.02 1 .98 .96 2 .94 .91 3 .91 .86 4 .87 .82 5 .84 .78 6 .81 .75 7 .79 .72 8 .76 .70 9 .74 .68 10 .72 .65
L171 4’ Length S3 Spacing 30° 3000K Std 740 lm
70
50
30 0 70 50 30 0 1.02 1.02 1.00 1.00 1.00 .86 .94 .93 .96 .94 .93 .82 .88 .85 .92 .89 .87 .78 .83 .80 .89 .85 .82 .75 .78 .75 .86 .81 .78 .72 .74 .71 .83 .78 .74 .69 .71 .68 .80 .75 .71 .67 .68 .66 .78 .72 .68 .64 .66 .63 .75 .69 .66 .62 .64 .61 .73 .67 .63 .60 .62 .59 .71 .65 .61 .58
Polar Candela Distribution
20 .95 .88 .83 .78 .74 .71 .68 .65 .63 .61 .59
50 30 .91 .91 .88 .87 .84 .82 .81 .79 .78 .75 .75 .72 .72 .69 .70 .67 .68 .65 .66 .63 .64 .61
10 20 .91 .86 .81 .77 .73 .70 .67 .65 .63 .60 .59
Center Beam FC
-90°
90°
approx. 2800 cd max.
50 .88 .85 .82 .79 .76 .74 .71 .69 .67 .65 .63
30 .88 .84 .80 .77 .74 .71 .69 .66 .64 .62 .61
0 20 .88 .83 .79 .75 .72 .69 .67 .64 .62 .60 .58
0 .86 .82 .78 .74 .71 .68 .66 .63 .61 .59 .58
Illuminance at a Distance
180°
-45°
30
50 30 .95 .95 .91 .89 .87 .84 .83 .80 .79 .76 .76 .73 .73 .70 .71 .68 .69 .65 .66 .63 .64 .61
45°
Beam Width
3.0’
310.59
1.8’
1.8’
6.0’
77.65
3.6’
3.6’
9.0’
34.51
5.4’
5.4’
12.0’
19.41
7.2’
7.2’
15.0’
12.42
9.1’
9.0’
18.0’
8.63
10.9’
10.8’
0° Spread: 33.6°
0°
90° Spread: 33.4°
Coefficients Of Utilization Effective Floor Cavity Reflectance: 20%
RCC %: RW %: RCR: 0 1 2 3 4 5 6 7 8 9 10
80 70 50 30 0 1.02 1.02 1.02 1.02 .97 .95 .93 .91 .93 .89 .86 .83 .89 .83 .80 .76 .85 .79 .74 .71 .81 .75 .70 .67 .78 .71 .66 .63 .75 .68 .63 .60 .72 .65 .60 .57 .69 .62 .57 .54 .67 .59 .55 .52
70 70 50 30 .99 .99 .99 .95 .93 .91 .91 .87 .84 .87 .82 .79 .83 .78 .74 .80 .74 .70 .77 .70 .66 .74 .67 .63 .71 .64 .60 .68 .61 .57 .66 .59 .55
50 0 .85 .81 .76 .72 .68 .65 .61 .59 .56 .54 .52
50 30 .95 .95 .90 .88 .85 .82 .80 .77 .76 .73 .72 .69 .69 .65 .66 .62 .63 .59 .61 .57 .58 .55
30 20 .95 .87 .80 .75 .70 .66 .62 .59 .57 .54 .52
50 .91 .86 .82 .78 .74 .71 .68 .65 .62 .60 .58
30 .91 .85 .80 .76 .71 .68 .65 .62 .59 .56 .54
10 20 .91 .84 .78 .73 .69 .65 .62 .59 .56 .54 .52
50 .87 .83 .80 .76 .73 .70 .67 .64 .62 .59 .57
30 .87 .83 .78 .74 .70 .67 .64 .61 .59 .56 .54
0 20 .87 .82 .77 .72 .68 .65 .62 .59 .56 .54 .52
0 .85 .80 .75 .71 .67 .64 .61 .58 .55 .53 .51
Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.
t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada
Copyright © MP Lighting. All technical information in this document is subject to change.
10-2011