/L19_spec

Page 1

2 x 1W/2.5W Up and Down Walkway

L19

SPEC SHEET Application: Wall stairs and walkway illumination for indoor and outdoor applications. Electrical: 2 x 1W LEDs powered by 120V primary, 3W 350mA nondimmable integral driver or 2 x 2.5W LEDs powered by 120V primary, 700mA non-dimmable integral driver. Input Current: 350mA (2W) / 700mA (5W) Input Voltage: 8V DC Power Consumption: 2W / 5W Recommended Dimmable Driver: LED8W350i (2W) and LED20W700i (5W). Dimmable driver not included. Consult factory. Weight: 3.24lbs (1.47kg). Material: Stainless steel 316. Mounting: Vertically positioned face plate mounts to a single gang box with flush mounted tamper proof screws. Approval: Wet and dry locations. Approved to US and Canadian standards by CSA. 66 NOTE: Fixture may require remote driver for use in cold weather applications. Can be used as emergency backup lighting in conjunction with Bodine emergency LED driver (sold separately). Consult MP Lighting factory.

3-3/8” 86mm

2-1/2” 64mm

3-1/4” 83mm

5” 127mm

2-1/2” 64mm

1-1/8” 29mm

1/8” 3mm

Type: Project:

2-1/8” 54mm

Modified: Quantity: Notes:

Code L19

Wattage

Color UP

Beam UP

Color Down

Beam Down

-

Finish -

1 = 1W 2 = 2.5W*

W27S W30S W35S W41S W30H

= 2700K, std CRI = 3000K, std CRI = 3500K, std CRI = 4100K, std CRI = 3000K, high CRI

1 = 12° 3 = 30° 12 = 120°

W27S W30S W35S W41S W30H

= 2700K, std CRI = 3000K, std CRI = 3500K, std CRI = 4100K, std CRI = 3000K, high CRI

1 = 12° 3 = 30° 12 = 120°

S S = stainless steel 316

*Only available in W30S (3000K, std CRI).

t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada

Copyright © MP Lighting. All technical information in this document is subject to change.

01-2011


2 x 1W/2.5W Up and Down Walkway

L19

SPEC SHEET Photometric Data

L19 2 x 1W, 12° 3000K Std 170 lm

Polar Candela Distribution 180°

2

-90°

90°

1

0

2

approx. 700 cd max.

45°

-0°

4

-90°

5

2 90°

1

0

approx. 275 cd max.

45°

New Mounting Height² Step 2

= Correction Factor (CF)

CF x Footcandle = New Mounting Height FC

Note: Information is based on the most current data available; however, various operating factors such as reflectances and application type may cause differences between lab and field results. Due to continuous improvements, specifications may change without notice. Consult www.mplighting.com for the most current information.

0

1

2

3

0.1 fc

3

-0°

4

-90°

5

Mount height: 1 ft Total LLF: 1

Polar Candela Distribution

Isofootcandle Plot

180°

2

-90°

90°

1

0

2

approx. 28 cd max.

45°

4

-90°

5

1

2

3

0.1 fc

3

-0°

0

20 2.5 1

1

Mount height: 1 ft Total LLF: 1

Polar Candela Distribution

Isofootcandle Plot

180°

2

-90°

90°

0 1 2

-45°

Existing Mounting Height²

20 10 0.5

2

L19 2 x 2.5W, 12° 3000K Std 324 lm

Step 1

Isofootcandle Plot

180° -90°

-45°

3

0.1 fc

1

L19 2 x 1W, 120° 3000K Std 170 lm

2

Mount height: 1 ft Total LLF: 1

Polar Candela Distribution

-45°

1

3

L19 2 x 1W, 30° 3000K Std 170 lm

0

20 10 0.5

1

-45°

Height Conversion Formula

Isofootcandle Plot

approx. 1300 cd max.

45°

1

0

1

2

3

20 5 0.5 0.1 fc

3

-0°

4

-90°

5

Mount height: 1 ft Total LLF: 1

Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.

t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada

Copyright © MP Lighting. All technical information in this document is subject to change.

01-2011


2 x 1W/2.5W Up and Down Walkway

L19

SPEC SHEET Photometric Data

L19 2 x 2.5W, 30° 3000K Std 324 lm

Polar Candela Distribution 180°

2

-90°

90°

1

0

2

approx. 530 cd max.

45°

-0°

4

-90°

5

2

3

Step 1

Step 2

0.1 fc

2 90°

0 1 2

approx. 55 cd max.

= Correction Factor (CF)

CF x Footcandle = New Mounting Height FC

Note: Information is based on the most current data available; however, various operating factors such as reflectances and application type may cause differences between lab and field results. Due to continuous improvements, specifications may change without notice. Consult www.mplighting.com for the most current information.

Isofootcandle Plot

180° -90°

Existing Mounting Height² New Mounting Height²

Mount height: 1 ft Total LLF: 1

Polar Candela Distribution

-45°

1

3

L19 2 x 2.5W, 120° 3000K Std 324 lm

0

20 2.5 0.5

1

-45°

Height Conversion Formula

Isofootcandle Plot

45°

3

-0°

4

-90°

5

1

0

1

2

3

20 5 1 0.1 fc

Mount height: 1 ft Total LLF: 1

Note: Various operating factors may cause differences between lab and field results. As specifications may change without notice, please refer to the LED Lamp Index located in the “Downloads” section of each product webpage for the most current information.

t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada

Copyright © MP Lighting. All technical information in this document is subject to change.

01-2011


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.